1. 011 453 53 23 Fax 39 011 453 70 49 SHANGHAI ufficio di rappresentanza Minhang Residence Room 506 N 50 Jinzhu Road 200336 Shanghai CHINA Tel Fax 86 21 62086781 e mail infoshangai hrcctv com e mail info hrcctv com web www hrcctv com Codice Fiscale e Partita IVA 06397551000 Iscrizione R E A 966880 B series Ver1 0 8
2. beams to interrupt to trigger receiver jumper JMP2 RECEIVER RX setting 402 Ooo LED acceso fisso se la barriera allineata e operativa LED ON if power is present and beams are aligned LED lampeggiante su interruzione dei fasci LED flashes when beams are 31040 Allarme neral dall interruzione di un singolo fascio Triggers if any beam is interrupted 102 ooo LED spento se la barriera allineata e operativa LED OFF if power is present and beams are aligned LED lampeggiante su interruzione dei fasci LED flashes when beams are broken mm Allarme generato dall interruzione simultanea di 2 fasci adiacenti Triggers only if 2 adjacent beam interrupted at same time ponticelli marcati JMP1 e JMP si trovano nella scheda interna al profilato di alluminio The jumpers marked JMP1 and JMP2 are located in the inner pcb PORTATA OPERATIVA Operational Range La portata dipende dall allineamento dalle riflessioni e dalla luminosit ambientale Il TX viene adattato variando la potenza emessa tramite i ponticelli S1 ed S2 da un minimo di 5m a un massimo di 15m in esterno Dopo aver individuato il livello minimo sufficiente al funzionamento passare al livello superiore La potenza eccessiva pu compromettere il funzionamento a causa di riflessioni mentre la potenza scarsa pu provocare falsi allarmi in occasione di variazioni della luminosit su RX L unit RX non richi
3. the product Slots and openings are provided for ventilation and should never be covered Do not place under direct sunlight or heat sources INFORMAZIONI SULL AMBIENTE ENVIRONMENT INFORMATION Note per lo smaltimento del prodotto valide per la Comunit Europea Questo prodotto stato progettato e assemblato con materiali e componenti di alta qualit che possono essere riciclati e riutilizzati Non smaltire il prodotto come rifiuto solido urbano ma smaltirlo negli appositi centri di raccolta E possibile smaltire il prodotto direttamente dal distributore dietro l acquisto di uno nuovo equivalente a quello da smaltire Abbandonando il prodotto nell ambiente si potrebbero creare gravi danni all ambiente stesso Nel caso il prodotto contenga delle batterie necessario rimuoverle prima di procedere allo smaltimento Queste ultime debbono essere smaltite separatamente in altri contenitori in quanto contenenti sostanze altamente tossiche Il simbolo rappresentato in figura rappresenta il bidone dei rifiuti urbani ed tassativamente vietato riporre l apparecchio in questi contenitori L immissione sul mercato dopo il 1 luglio 2006 di prodotti non conformi al DLgs 151 del 25 07 05 Direttiva RoHS RAEE amministrativamente sanzionato Disposal of waste products for European Union This products was designed to minimize their impact on the environment by reducing or eliminating hazardous materials and designing for recyclables Thi
4. Barriera IR Multifascio Multi IR beam barrier SECURIIN MANUALE TECNICO Technical Manual NORME GENERALI DI SICUREZZA General safety recommendations Sicurezza delle persone Safety warnings a Leggere e seguire le istruzioni Tutte le istruzioni per la sicurezza e per l operativita devono essere lette e seguite prima che il prodotto sia messo in funzione Precauzioni particolari Rispettare tassativamente l ordine delle istruzioni di installazione e collegamento descritte nel manuale Verificare le indicazioni riportate sulla targa di identificazione esse devono corrispondere alla vostra rete elettrica di alimentazione ed al consumo elettrico Conservate le istruzioni per una consulta futura Read and follow the instructions Read the installation instructions before connecting the system to its power source Follow these guidelines to ensure general safety In order to prevent injury burns or electrical shock to yourself and others follow the connection instruction plan carefully Sicurezza del prodotto Product Safety Non posizionare in prossimit di liquidi oppure in un ambiente ad umidit eccessiva Non lasciare penetrare del liquido o corpi estranei all interno dell apparecchiatura Non ostruire le griglie di aerazione Non sottoporre all esposizione dei raggi solari oppure in prossimit di fonti di calore Do not use the product in a wet location Never push a foreign object through an opening inside
5. al block housing are the knockout holes for wire entry the wire must curve 909 e Insert the brackets in the aluminium structure and fix the units by screws and dowels in equipment e Connect the wires to the terminal block e Replace the inner cup pay attention to not move the inner cup seal joint e After alignment screw the rotary axes fixation screw to immobilize the units in the best position e Replace the front cover IMPORTANTE Posizionare le unit una di fronte all altra con il lato morsettiera rivolto nella stessa direzione IMPORTANT Locate the units face to face with the terminal block side in the same direction NO B series Ver1 0 3 IMPOSTAZIONI Settings Impostazioni sull unita TRASMETTITORE TX Regolazione Portata Distance Adjust Modalita Buzzer Buzzer Mode jumper JMP2 Buzzer OFF DO on ON OFF A Interruzione di 1 solo fascio Buzz if any beam is interrupted TRANSMITTER TX setting Interruzione simultanea di 2 fasci adiacenti Buzz if 2 adjacent beam is interrupted OFF SEN ON uzzer disabilitato disabled Buzzer abilitato enabled ponticelli marcati S1 S2 e JMP2 si trovano nella scheda interna al profilato di alluminio The jumpers marked S1 S2 and JMP2 are located in the inner pcb Impostazioni sull unit RICEVITORE RX Funzionamento del LED LED Operation jumper JMP1 Modalita di Allarme Number of
6. ede regolazioni della portata The range depends on the alignment reflections and environmental brightness The TX unit can be adapted by setting distance trough S1 and S2 jumpers from a minimum of 5m to a maximum of 15m outside After having identified the minimum level sufficient to operation step to upper level The excessive power can compromise the operation due to reflections and the insufficient power can generate alarms in case of brightness variations on RX RX unit does not require distance adjustment B series Ver1 0 4 ORIENTAMENTO Orientation La luce solare pu ridurre la sensibilit del ricevitore sino a provocare falsi allarmi Per evitare abbagliamenti orientare verso Nord l unit RX verificando il movimento del sole The sunlight can reduce the sensibility of receiver with consequent false alarms In order to avoid dazzling orient towards North RX unit verifying the movement of the sun 1 i i i a x i P A i Ji i k Sa a i a E ho ih A J a 7 hy Lt a i i 1 INSTALLAZIONI MULTIPLE Multiple Installation Nel caso sia richiesta l installazione di pi barriere una sopra l altra o affiancate necessario alternare sullo stesso lato TX e RX in modo da evitare interferenze If multiple installation is required it is necessary to alternate on the same side RX with TX in order to avoid interferences NO OK R 10 Nelle contin
7. he date of purchase obtained only against presentation of the original invoice cash ticket issued to the customer by the retailer Warranty repair service is excluded if damage or defects have been caused by Improper use incorrect storage dropping or shocks corrosion dirt water handing or operation of the product as referred to in the users manuals Repairs modifications or cleaning carried out at a service centre not authorized by HR EUROPE Accidents or disasters or any cause beyond the control of HR EUROPE including but not limited to lightning water fire improper supply voltage or ventilation B series Ver1 0 INTRODUZIONE Introduction Le barriere multifascio ad infrarossi attivi serie B sono state progettate sia per applicazioni in interni quali la sorveglianza di corridoi serie di finestre o porte che per applicazioni in esterni quali la sorveglianza di recinzioni e perimetri Sono costituite da un unit trasmittente che invia dei fasci sincronizzati di luce invisibile all infrarosso e da un unit ricevente cui spetta il compito di valutare l energia luminosa incidente generando un allarme nel caso in cui un corpo opaco venga ad interporsi fra trasmettitore e ricevitore La barriera genera allarme in caso di interruzione di uno o di due fasci adiacenti secondo modalit programmabile l unit ricevente segnala lo stato di allarme tramite un LED locale e i contatti del rel mentre il trasmettitore attiva il buzzer i
8. nterno se abilitato L originale supporto girevole permette di orientare le unit per ottenere il migliore allineamento possibile in qualsiasi posizione di montaggio Le barriere sono disponibili in diverse lunghezze e colori Multibeams electronic protection rail B series have been designed for indoor applications such as the surveillance of corridors series of windows or doors and for outdoor applications such as the surveillance of fences and perimeters They are constituted by a transmitter unit that send synchronized beams of infrared light to a receiver unit that evaluate the incident luminous energy generating an alarm when a body cross through the beams or interrupt them continuously The barrier generates alarm upon simultaneous blocking of any single or 2 adjacent beams according to programmable alarm mode the receiver signals the alarm through a local LED and by relay contacts and the transmitter trigger the internal buzzer if enabled The original rotating brackets allow the orientation of the units to reach the best alignment in any mounting location The barriers are available in various lengths and colours INSTALLAZIONE Installation e Sfilare i supporti che sono inseriti a pressione nel profilato della barriera e rimuovere i coperchi frontali dei supporti svitando la vite e Rimuovere i coperchietti interni svitando 3 viti All interno del coperchio esterno sono presenti 2 fori premarcati che bisogna rompere per consen
9. perchio frontale Coperchio frontale Coperchio interno Vite del coperchio interno Interruttore tamper Guaina di protezione Fori utilizzati per il fissaggio Base plastica Giunto Vite di blocco Inserto rotatorio 12 Morsettiera B series Ver1 0 NOAR UNS 10 de 12 Front cover lock screw Front cover Inner cup Inner cup lock screw Tamper switch Inner cup seal joint Mounting holes amp Base seal Base End cup Rotary axes fixation screw Rotary axes seal Terminal block COLLEGAMENTI Connection Utilizzare cavo schermato per effettuare i collegamenti tra le unit TX RX e l unit centrale Lo schermo del cavo di interconnessione tra le unit TX e RX deve essere allacciato allo schermo del cavo uscente dal ricevitore che deve essere collegato a terra nell unit centrale Use shield wire to connect TX RX and control panel The shield of the interconnection cable between TX and RX units must be connected to the shield which goes out from the receiver and must be connected to the ground in the control panel Tamper output Alarm output Power input 12V GND SIG CONTROL PANEL Z2 is 24h zone First Rail second Rail Third Rail B series Ver1 0 7 SPECIFICHE TECNICHE Technical Specifications 12vdo Portata massima Maximum range 15m in esterno outdoor 30m in interno indoor Orientamento orizzontale Horizontal orientation 180 Dimensioni comprensive di s
10. s product should be handed over to a designated collection point e g on an authorized one for one basis when you buy a new similar product or to an authorized collection site for recycling waste electrical and electronic equipment Improper handling of this kind of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances This symbol indicates that this product has not to be disposed of with your household waste according to the WEEE Directive For more information about where you can drop off your waste equipment for recycling please contact your local city waste authority or your household waste disposal service GARANZIA Warranty Questa garanzia ha validit di 2 anni a partire dalla data di acquisto assicurata solo dietro presentazione della fattura o scontrino rilasciati al cliente dal rivenditore L assistenza gratuita non prevista per i guasti casauti da Uso imprprio del prodotto immagazinamento inadeguato cadute o urti usura sporcizia acqua sabbia manomissione da personale non autorizzato del prodotto rispetto a quanto previsto nei manuali d uso inclusi Riparazioni modifiche o pulizia effettuate da centri assistenza non autorizzati da HR EUROPE Danni o incidenti le cui cause non possono essere attribuite alla HR EUROPE comprendenti e non limitati a fulmini eventi naturali alimentazione e ventilazione inadeguata This warranty is valid for 2 years from t
11. tire il passaggio dei cavi provenienti ad esempio da una canalina esterna e Se il cavo proviene da canalina esterna rompere anche i fori premarcati del supporto che va a contatto con la superficie di montaggio e Se i cavi provengono da impianto incassato a muro utilizzare i 2 fori circolari gi aperti e Rompere 2 fori premarcati del supporto per consentire il passaggio del cavo nella vaschetta che alloggia la morsettiera il cavo deve curvare di 90 e Inserire i supporti nel profilato e fissare le unit a muro mediante il set di viti e tasselli in dotazione e Effettuare i collegamenti alla morsettiera su entrambe le unit e Rimontare i coperchi interni con particolare attenzione a non spostare la guaina di protezione in gomma e Dopo le operazioni di allineamento stringere le viti di blocco per immobilizzare la barriera nella posizione ottimale e Rimontare i coperchi esterni e Take out the brackets that are inserted in the aluminium structure and remove the front covers of the brackets by unscrew the lock screw e Remove the inner cups by unscrew 3 holding screws The semicircular identifications on the interior side of front cover are the knockout holes for wire entry if the wires come from an external duct In this case break out also the semicircular identifications of the bracket e When the wires come out of the wall push the wire through the circular holes on the bracket base e The circular identifications on the termin
12. uazioni di tratta procedere nell installazione come nella figura sottostante If more distance is required please follow installation as the picture below shows B series Ver1 0 5 PROTEZIONE ANTIMANOMISSIONE Tamper Protection Ogni unita dispone di un contatto antiapertura situato sotto il coperchio del supporto lato morsettiera Se e richiesta la funzione di antimanomissione collegare i terminali marcati TAMPER dell unit RX ad una zona 24 ore della centrale di allarme Se il coperchio del ricevitore venisse aperto il segnale di allarme verrebbe trasmesso immediatamente alla centrale di controllo NOTA Durante la fase di test necessario montare il coperchio interno del trasmettitore in modo da chiudere l interruttore tamper La condizione di allineamento si ottiene solo quando il tamper del trasmettitore risulta chiuso Every unit has a tamper switch located under the inner cup If a tamper function is required connect the terminals marked TAMP on the RX unit to a 24 hour normally closed protective zone in the control unit If the cover of RX is opened an immediate alarm signal will be sent to the control unit NOTE during the test procedure it is necessary assemble the inner cup on TX unit in order to lock the tamper switch The alignment condition is achievable only when the TX tamper switch is closed DESCRIZIONE SUPPORTO Bracket Description 1 2 3 4 S 6 7 8 9 Vite del co
13. upporti 560x33x35mm Dimensions with bracket 760x33x35mm cod Bx56 cod Bx76 1120x33x35mm cod Bx112 1520x33x35mm cod Bx152 2000x33x35mm cod Bx200 NOTA x identifica il codice colore NOTE x identifies the Colour Code Numero di fasci Number of beams 3 fasci doppi 3 double beams cod Bx56 4 fasci doppi 4 double beams cod Bx76 6 fasci doppi 6 double beams cod Bx112 8 fasci doppi 8 double beams cod Bx152 10 fasci doppi 10 double beams cod Bx200 NOTA x identifica il codice colore NOTE x identifies the Colour Code Materiale Material Alluminio Aluminium Colore Codice colore Colour Colour Code Bianco B White B Nero N Black N Marrone M Brown M Grigio G Grey G Specifiche tecniche soggette a variazioni senza preavviso Technical specifications can be modified without any preliminary notice CONFORMITA DEL PRODOTTO Conformity Le barriere serie B sono conformi ai requisiti essenziali delle direttive The infrared barriers B series are conforms with the essential requirements set out by 89 336 EEC Electromagnetic Compatibility directive 73 23 EEC Low Voltage directive modified by 93 68 EEC Low Voltage directive HR EUROPE s r l ROMA sede legale e amministrativa Via Giulianello 1 7 00178 Roma ITALIA Tel 39 06 7612912 Fax 39 06 7612601 TORINO sede operativa Via G B Feroggio 10 10151 Torino ITALIA Tel 39