1. ENGLISH 1 INTRODUCTION SMILE T6 is a digital microprocessor controlled PIR Due to its innovative numerical sampling and process ing AMC DMS Digital Modulation System of the PIR signal 2 elements it has a detection range of up fo 18 m away from the detector with an angle of over 90 and allows to distinguish the true motion from any www amcelettronica com SMILE 16 Digital Pir Detector nstallaton Instructions v1 1 l other disturbances causing false alarms lt features a regulator to adjust its range from 3 m to 18 m and a double impuise event counter with a time window of 5 sec selectable in installations where an improved protection against false alarms IS required The housing does not require any screws neither to fasten the electronic board to the base nor to open the detector 10 disassemble the detector just press the tooth on the bottom of the case see figure and pull out the PCB by pushing the clp and by levering on the ABS Supports see figure In this way it will be possible to freely work on the PCB Thanks to the termina BLOCK SENSOR BIS it is possible to activate and disable the Walk Test LED without opening the housing 2 INSTALLATION PROCEDURE By using a thin screwdriver push the round tooth on the bottom see figure 1 and open the housing Remove the PCB from the base figure Use a screwdriver to pierce the knockouts on the side of the base where you wish to attach the detector fo the wal
2. Modu lation System it allows a range of 18 mi the Special lens Shape pro vides a horizontal cove rage of more than 90 with 29 pattems on 5 levels WWW amMceeretironica com SMILE 16 Digital Pir Detector 2 nstallaton Instructions v1 1 SPECIFICHE TECNICHE SPECIFICATIONS SPECIFICATIONS TECHNIQUES Portata in larghezza Angle Angle de couverture DO Lente Lens Lentille Durata allarme Alarm period Duree alarme Compesazione termica Thermical compesation Compensation thermique MA Ant opening SIRIO CA WE Antistiscianento Creep zone Detection sous le detector S OO Contatto di tamper Tamper switch Contatci d auto vroftection max 40 mA 30 Voc Contatore impulsi Event counter Comptage d impufsion 2 count for 5 sec selectable Temperatura di esercizio Operating temperature Temperature de fonction from 10 C fo 55 C nement CI s Cover Cover Mowsitg Beter Bolter Accessori e nr ccessories Accessoires snodo orentabrle lE Swivel bracket fotule orientabile Non coperto da omologazione IMQ Meets the requirements Conforme ai requisiti Ro H S R amp TTE 99 5 CE EN 50131 2 2 2008 a 500 tel EN 50131 2 2 Grade 2 EN 50131 2 2 Class 2 CEI 79 2 I Level 6 Prodotto conforme alla Direttiva 99 5 CE La dichiarazione di conformit disponibile presso la nostra sede Tutti i ns prodotti sono conformi ai requisiti richiesti dalla norma CE
3. la port e de infrarouge de 3 m 18 m proc der comme suit Mettre le potentiom etre COVERAGE au minimum sens anti horaire puis augmenter celui ci Sens horar re pas pas afin d obtenir la port e desrr e www amcelettronica com SMILE 16 Digital Pir Detector nstallaton Instructions v1 1 l 1 General View 2 Inside View 3 MORSETTIERA CENTRALE CONTROL PANNEL TERMINALS OPEN COLLECTOR ALARM ARM DISARM CONTACT e 13 8VDC E e hg TAMPER e SUPPLY SS S S TAMPER 13 5 LENTE LENS VISTA LATERALE CLL Bm Copertura minima ALIMENTAZIONE SUPPLY Er zz STOP WALK 8 TEST ALLARME ALARM HE n CII 12m 14m 18m Copertura massima 4 CONFIGURAZIONE COVERAGE From 3 mt to 18 mt SETTINGS N O 1 count N C 2 count TAMPER 78 SUPPLY bu TTO E gg 2m 4m 6m 12m 14m 18m AMC DMS Digital Modula tion System permette una copertura di 18 mi la spe ciale conformazione della lente permette un apertura orizzontale di oltre 90 con 29 fasci su 5 livelli 5 an tavvicinamento 6 a corta portata 7 a media portata 6 a media lunga porfata 5 a lunga portata Sf raccomanda di non o OSCUrare ne parzialmente ne completamente M cam po di visione del rilevatore AMC DMS Digital
4. CELLES CN en AME SMILE 16 INSTALLAZIONE SENSORE INFRAROSSO CON TECNOLOGIA DIGITALE INSTALLATION DIGITAL PIR DETECTOR DETECTEUR INFRAROUGE 1 INTRODUZIONE SMILE 16 un sensore ad infrarosso di tpo digitale con microcontrollore Grazie all innovativo sistema di acquisizione e elaborazione numerica del segnale AMC DMS Digital Modulation System proveniente dal piroelettrico 2 elementi in grado di garantire una copertura in lunghezza di oltre 18 mt e in larghezza di oltre 90 garantendo un assoluta sicurezza contro i falsi allarmi E dotato di un regolatore di portata con ll guale possibile settare la sensibilit da 3 a 18 mi ha un contatore a doppio impulso con finestra di tempo di 5 attivabile in caso di installazioni dove sia richiesta una protezione maggiore contro i falsi allarmi Lin gegnernzzazione meccanica sfata realizzata in modo fale da non utilizzare viti sia per ll fissaggio della scheda all interno della cover che per l apertura del sensore stesso Per accedere alla scheda elettronica sara sufficiente fare pressione su un tasto sul fondo della cover vedi figura e facendo leva sui blocchetti Nn ABS si potr estrarre la scheda elettronica e lavorare in piena libert Grazie all ingresso di BLOCCO SENSORE B S possibile attivare e disattivare Il led di Walk Test senza aprire la cover 2 INSTALLAZIONE Utilizzando uno strumento sottile esempio mini cacciavite a taglio spingere ll fastino fondo
5. I 79 2 2 ed 1998 Ab 2000 L installazione deve essere eseguita a regola d arte da personale specializzato Il produttore declina ogni responsabilit nel caso in cui il prodotto venga manomesso da persone non autorizzate Si raccomanda di verificare il corretto funzionamento del sistema d allarme almeno una volta al mese tuttavia un sistema di allarme elettronico affidabile non evita intrusioni rapine incendi o altro ma si limita a diminuire il rischio che tali situazioni si verifichino This product comply the 99 5 CE directive The declaration of conformity is available at our offices Our products systems comply with the essential requirements of EEC directives Installation must be carried out following the local installation norms by qualified personnel The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product system It is recommended to test the operation of the alarm product system at least once a month Despite frequent testing and due to but not limited to any or all of the following tampering electrical or communication disruption or improper use it is possible for the product system to fail to prevent burglary rubbery fire or otherwise A properly installed and maintained alarm system can only reduce the risk that this happens Produit conforme la Directive 99 5 CE La d claration de conformit est disponible chez notre soci t Tous nos produits sont conformes au
6. l or use the optional swivel bracket height Route the wires via the rear channel into the base and let them pass through the hole on the top of the housing see figure Wire up the ferminals following the connections shown in figure 3 CAUTION Do not partially or totally obscure the field of view of the detector 3 CONNECTIONS AND SETTINGS As for the connections with the control unit please refer to figure 3 Jo disable the LED WALK TEST you have fo apply a voltage of 13 8 VDC at terminal B S while if you want to disable it only when the control unit is disarmed connect a plus voltage only when the system IS disarmed ff the control unit does not have a plus voltage command but a ground voltage command con nect the terminal B S fo both the power supply plus through a 1 KQ resistor and to a system status open collector output ground voltage output of the control unit see figure 3 With JUMPER 1 it rs possible to determine if the detector trigger an alarm after 1 or 2 consecutive motons JPT OPEN 1 impulse CLOSED 2 impulses within 5 sec t IS possible fo adjust the coverage within the range 3 m to 18 m In an usual residential premse it iS Sug gested to regulate the trimmer at half its range FRAN AIS 1 INTRODUCTION Le SMILE 16 est un d tecteur infrarouge digital avec un microcontr eur Gr ce innovant syst me d acquisition et de traitement num rique du signal AMC DMS Digital Modula ton System d
7. sul lato ante nore del sensore vedi figura 1 e aprire la cover rimuovere la scheda elettronica dal fondo della cover facendo leva sulla clips lato morsetti figura forare gli sfondabili che si desidera utilizzare per il fissaggio oppure utilizzare l apposito snodo opzionale Altezza consigliata per ll fissaggio 2m fare scorrere ll cavo di collegamento attraverso l apposita guida sul retro della cover facendolo uscire dal foro in alto figura cablare N circuito seguendo la guida ai collegamenti figura 3 ATTENZIONE Non oscurare parzialmente o totalmente il campo di visione del rivelatore 3 COLLEGAMENTO E REGOLAZIONE Per guanto riguarda il collegamento alla centrale fare riferimento allo schema 3 Per disabilitare completamente il LED WALK TEST necessario fornire una tensione 13 8 VDC fissa al morsetto B S al contrario se si desidera disabilitario solo a sistema disarmato collegare un positivo solo a centrale disinserita oppure fare un pull up con una resistenza da 1 KO sul morsetto B S e collegarlo ad una uscita open collector di stato impianto della centrale vedi schema 3 Con JUMPER 1 possibile configurare il sensore a dare allarme con 1 0 2 evazioni JPT APERTO 7 impulso CHIUSO 2 impulsi in 5 E possibile regolare la portata da 3 mt a 18 mi normalmente in un impiego di tpo residenziale dove locali protett non sono eccessivamente grandi consigliato regolare ll trimmer a met corsa
8. u d tecteur pyro ectrique 2 l ments une port e de 18m ef un angle de couverture de 90 garantissent une protection optimale contre les declenchements intempestifs Le SMILE 16 est quip d un r gulateur de port e avec eque il est possible de r gler la sensibilit de 3 18 m et d un comptage d impuision avec une fen tre de temps de 5 aciivable dans les cas o est requise une haute protection contre les d clenchements intempestifs La conception m canique a t r alis e de telle fa on ne pas utiliser de vis pour la fixation de la platne ectronique l int rieur du d tecteur et pour ouverture du capot du SMILE T6 2 INSTALLATION Pour l installation ouvrir le d tecteur en pressant sur le pett clip se trouvant dans la partie inf rieure aide d un petit tournevis voir fig1 puis d clipser la platne lectronique voir fig 2 D foncer les pr percements ou utiliser une rotule suivant le type d installation purs faire sortir le cable de raccordement dans la partie sup rieure et fixer le fond ATTENTION Ne pas occulter partiellement ou totalement le champ de vision du d tecteur 3 CABLAGE ET REGLAGE Cabler le d tecteur en respectant la polant vor ig 3 Il est possible de d sactiver la LED de fest en activant entr e B S par une tension vor 19 3 Selection du comptage d impulsion gr ce au Jumper JPT voir ig 4 Ouvert 1 impulsion Ferm 2 imput sions de 5 Pour le r glage de
9. x requises pr vu par la norme CEl 79 2 ed 1998 Ab 2000 L installation doit tre effectu e dans les r gles de l art par un installateur qualifi AMC Elettronica S r l d cline toute responsabilit en cas d utilisation des produits par des personnes non habilit es Il est recommand de v rifier le bon fonctionnement du syst me d alarme au moins une fois par mois Un syst me d alarme lectronique n exclut pas le risque d intrusion de vol d incendie mais limite et diminue fortement celui ci www amcelettronica com SMILE 16 Digital Pir Detector nstallaton Instructions v1 1 3