1. CENTRALE FC Li FC CONTROLLER FC ZENTRALE O gt DISPOSITIVO ESTERNO CIRCUITO COMMUTABILE ALIMENTATORE EXTERNAL DEVICE DI hi Ge UNIT SWITCHABLE CIRCUIT Ven EIN UND AUSSCHALT e GE S VERSORGUNG BARER VERBRAUCHER ze a re Eug ole cal S le S CIRCUITO ELETTRONICO SWITCHING olle ELECTRONIC SWITCHING CIRCUIT 8 CHALTBARE BAUGRUPPE O Oza j FIG 4 FC410RIM Schema di collegamento FC410RIM Simplified Wiring Diagram Typische Verdrahtung des FC410RIM
2. EINBAU INS FC470CV ANCILLRY GEH USE FC470CV Geh use Orberteil ist extra zu bestellen Best Nr FC470CV 1 Befestigen Sie di FC410RIM an der Montageplatte von FC470CV benutzen Sie daf r die gelieferte vier Schrauben und Scheiben 2 Bauen Sie den Deckel auf den doppelten Untergeh use VERKABELUNG An die Anschlussklemmen k nnen Kabel mit Drahtquerschnitten bis zu 1 5 mm angeschlossen werden Es werden geschirmte Brandmeldekabel des Typs J Y ST Y nx2x0 8 empfohlen ANSCHLIEREN 1 Am FC410RIM m ssen keine DIP Schalter oder Steckbr cken Einstellungen vorgenommen werden 2 Alle Leiter m ssen erdfrei sein 3 Stellen Sie die korrekte Polung der Verkabelung sicher bevor Sie das FC410RIM an die Ringleitungsspannung anschlie en 4 Abbildung 4 zeigt eine typische Verkabelung des FC410RIM Abb 1 FC Ausgangselement nicht berwacht FC410RIM ENGLISH TECHNICAL SPECIFICATION Type Identification Value 161 System Compatibility Use only with FC Fire Alarm Controllers Environment Indoor Application only Operating Temperature 25 to 70 C Storage Temperature 40 to 80 C Operating Humidity Up to 95 non condensing Dimensions HxWxD 87 x 148 x 14 mm Mounting Requirements One FC backbox surface mount Battery Requirements Standby Current 0 46mA max Alarm Current 4 5mA max Addressable Device Condi tions Normal Active Output Stuck Device Type Invalid Device No Response Relay Co
3. 14 mm A parete su scatola FC Corrente a riposo 0 46 mA Corrente in allarme 4 5 mA Stati del dispositivo indirizzabile Normale Attivo Uscita bloccata Dispositivo non valido Dispositivo non risponde CC 2A 24 Vcc t Nota Il modulo non deve essere usato per commutare la tensione di rete Min 1 5 mm Max 2 5 mm Caratteristiche del contatto rel Sezione cavi consigliata Compatibilit Elettromagnetica Il modulo FC410RIM conforme a quanto segue gt famiglia di prodotto standard EN50130 4 rispetto alle Perturbazioni Dirette Immunit Irradiata Scarica Elettrostatica Transitorie Rapide e Alta Energia Lenta gt EN50081 1 per le emissioni INTRODUZIONE Il modulo rel FC410RIM fornisce uno scambio libero da tensione su un ag gancio del rel Il rel controllato tramite un comando inviato dalla Centra le FireClass attraverso il loop indirizzabile Lo stato del rel attivo non attivo o collegato inviato alla Centrale CARATTERISTICHE Il modulo FC410RIM include le seguenti caratteristiche gt Funzione Indirizzabile La Centrale trasmette un comando operativo al rel il quale segnala lo stato di attivazione o disattivazione alla Centrale che utilizza un insieme di contatti dedicati al controllo dello stato del rel gt Uscita rel con uno scambio libero da tensione gt Uscita per il controllo di un rel alta tensione HVR800 gt II LED che indica lo stato no
4. has been programmed take note of the device location and address number to include on site drawings CABLING The maximum section of the cable that can be connected at any one termi nal is 2 5mm2 The section is calculated based on the characteristics of the cable and the load ORDERING INFORMATION FC410RIM Relay Input Module FC470CV Double Gang cover RECYCLING INFORMATION Customers are recommended to dispose of their used equipments panels detectors sirens and other devices in an environmentally sound manner Potential methods include reuse of parts or whole products and recycling of products components and or materials WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE DIRECTIVE In the European Union this label indicates that this product should NOT be disposed of with household waste It should be deposited at an appropriate facility to enable recovery and re cycling The manufacturer reserves the right to change the technical specifications of this product without prior notice FIG 1 FC410RIM Relay Interface Module ITALIANO SPECIFICHE TECNICHE Valore Identificativo 161 Compatibilit usare solo con Centrali serie FC Caratteristiche ambientali Temperatura di funzionamento Temperatura di stoccaggio Umidit relativa Dimensioni HxLxP Requisiti di montaggio Corrente assorbita Solo per applicazioni interne da 25 a 70 C da 40 a 80 C fino a 95 senza condensa 87 x 148 x
5. FireClass FC410RIM MODULO REL RELAY INTERFACE MODULE FC AUSGANGSELEMENT NICHT UBERWACHT OQ oO CO oO co N CH oO Q oO S zt LL m Sch a D D ES D LO i CH N re Lu H iL lt L ui A IN DEUTSCH Best Nr 568 800 703 ANWENDUNG Das FC Ausgangselement FC410RIM stellt einen potentialfreien Relaisausgang Umschalter 24 V DC 2 A zur Verf gung Es kann mit FireClass 500 Console auf zwei Betriebsarten eingestellt werden gt T rsteuerung gt Steuerung TECHNISCHE DATEN System Kompatibilitat Adressierbares FC Brandmeldesystem Elementtyp Kennung 161 Spannungsversorgung aus der Ringleitung 20 bis 40 V Stromaufnahme im Bereitschaftsbetrieb 0 3 mA im Alarmzustand mit roter LED 3 mA Relais Schaltleistung 30 VI2 A Umgebungstemperatur im Betrieb 25 bis 70 C Luftfeuchte max 95 ohne Betauung Geh useabmessungen B x H x T 140 x 120 x 70 mm Gewicht 260 g CE 0832 BENTEL SECURITY s r l Via Gabbiano 22 Zona Ind S Scolastica 64013 Corropoli TE ITALY 09 0832 CPD 1228 EN 54 18 input output device for fire detection and fire alarm systems for buildings FC410RIM ADRESSEINSTELLUNG Per Auslieferungszustand ist de Adresse standardm ig auf 255 gesetzt Zum Einstellen der individuellen Systemadresse kann das Handprogrammierger t FC490ST am Programmierstecker angeschlossen werden siehe Abb 2
6. aders on the FC410RIM All wiring must be free of earths 2 All wiring must conform to the applicable standards 3 See Figure 4 for FC410RIM Simplified Wiring Diagram 4 For 24V dc powered applications only use a regulated supply suitable for fire protective signalling service 5 For powered circuit operation route the positive conductor through the FC410RIM to the external device while connecting the common neu tral conductor to the external circuit 6 For dry contact switching connect the external circuit to the COM and N O or N C terminals for normally open or normally closed operation as required 7 Verify that relay wiring is correct for the FC410RIM before connecting to the addressable loop circuit 8 For connection to an HVR800 High Voltage Relay Module refer to In stallation Sheet 17A 03 HVR or 120 415 528 INSTALLATION TO FC470CV DOUBLE GANG COVER 1 Assemble the FC410RIM to FC470CV Double Gang cover using the four screws and washers provided 2 Snap on the ancillary housing PCB cover 3 Fit cover onto FC backbox ADDRESS SETTINGS The FC410RIM has a default factory set address of 255 this must be set to the loop address of the device using the FC490ST Loop Service Tool The FC410RIM may be programmed with the address prior to being installed by using the internal programming port see Fig 2 or after being installed by using the programming port on the front cover see Fig 3 Note once the address
7. ntact Rating DC 2A 24V dc t Note The module must not be used to switch mains voltages Recommended Wire Size Min 1 5 mm Max 2 5 mm Electromagnetic Compatibility The FC410RIM complies with the following product family standard EN50130 4 in respect of Conducted Distur bances Radiated Immunity Electrostatic Discharge Fast Transients and Slow High Energy gt EN50081 1 for emissions INTRODUCTION The FC410RIM Relay Interface Module provides one volt free relay change over contact on a latching relay The relay is controlled by a command sent from the FC fire controller via the addressable loop The relay state acti vated deactivated or stuck is returned to the controller FEATURES FC410RIM features include the following gt Addressable functionality The control panel sends a command to operate the relay then reports an activated or deactivated state back to the panel through the use of a set of contacts dedicated to monitor the state of the relay gt One volt free dry contact relay output gt Output to drive a high voltage relay HVR800 gt LED status indicator which is normally off When the FC410RIM receives a command to activate the LED lights WIRING amp INSTALLATION NOTES A CAUTION THE O AND O TERMINALS MUST NOT BE USED FOR CONNECTING THE FC410RIM TO AN HVR800 SEE PUBLICATION 17A 03 HVR OR 120 415 528 The following notes apply 1 There are no user required settings switches he
8. rmalmente in OFF Quando il modulo FC410RIM riceve un comando di attivazione il LED si illumina NOTE PER IL COLLEGAMENTO E L INSTALLAZIONE A ATTENZIONE TERMINALI O E O NON DEVONO ESSERE UTILIZZATI PER IL COLLEGAMENTO DEL MODULO FC410RIM AL REL ALTA TENSIONE HVR800 CONSULTARE IL DOCUMENTO 17A 03 HVR OPPURE 120 415 528 Osservare le seguenti note 1 Sul modulo FC410RIM non ci sono regolazioni da effettuare interruttori o altro Tutti i conduttori devono essere senza terra 2 Tutti i collegamenti devono essere conformi alle norme applicabili 3 Vedere figura 4 per lo schema di collegamento del modulo FC410RIM 4 Per l alimentazione delle applicazioni 24 Vcc usare soltanto un alimentatore supplementare per la protezione del servizio di segnalazione incendio 5 Per il funzionamento alimentato del circuito portare il conduttore positi vo del modulo FC410RIM al dispositivo esterno ed il conduttore comune neutro al circuito esterno 6 Perla commutazione dello scambio libero collegare il circuito esterno ai morsetti COM e N O o N C per il funzionamento normalmente aperto o normalmente chiuso come necessario 7 Verificare la corretta polarit dei collegamenti prima di connettere il mo dulo FC410RIM al circuito loop indirizzabile 8 Peril collegamento ad un modulo rel ad alta tensione HVR800 consul tare il documento d installazione 17A 03 HVR oppure 120 415 528 INSTALLAZIONE NEL COPERCHIO FC470CV DOUBLE GANG 1 As
9. ropea questa etichetta indica che questo pro dotto NON deve essere smaltito insieme ai rifiuti domestici Deve essere depositato in un impianto adeguato che sia in grado di eseguire operazioni di recupero e riciclaggio si Il costruttore si riserva il diritto di modificare le specifiche tecniche di questo prodotto senza preavviso FIG 1 FC410RIM Modulo rel N VEL 22820202 2 lo oL IN HO N lgl win online L L L L 0 0 NO C NIC SEC O 3 PORTA DI PROGRAMMAZIONE Oo o 4 PROGRAMMING PORT CL d PROGRAMMIERANSCHLUSS O O l PORTA DI PROGRAMMAZIONE 7 ADDRESS SETTING PORT PROGRAMMIERANSCHLUSS FIG 2 FC410RIM fissata al coperchio FIG 3 FC410RIM Placca FC410RIM fitted to cover Facia Plate FC410RIM ins Geh use eingebaut Kurzschlussisolator Vorderseite o gt gt o gt L1 LL O L2 DOQo 00 ep 9 L L L L 0 0 NO C NIC
10. semblare l FC410RIM con il coperchio per scatole americane Dou ble Gang FC470CV usando le quattro viti e le rondelle fornite 2 Bloccare il PCB sull alloggiamento del coperchio 3 Fissare il coperchio sulla scatola FC PROGRAMMAZIONE L indirizzo di fabbrica del FC410RIM 255 questo deve essere impostato all indirizzo di loop del dispositivo tramite lo strumento per la programmazio ne dei dispositivi indirizzabili FC490ST L indirizzo del FC410RIM pu esse re programmato prima dell installazione usando la porta di programmazione interna vedere Fig 2 o dopo l installazione usando la porta di programma zione sul coperchio vedere Fig 3 Nota una volta programmato l indirizzo annotare la posizione del dispo sitivo e l indirizzo per segnarlo sul progetto dell impianto COLLEGAMENTI La sezione massima del cavo collegabile ad ogni morsetto di 2 5 mm La sezione va calcolata in base alle caratteristiche del cavo e del carico INFORMAZIONI PER L ORDINE FC410RIM Modulo rel FC470CV Coperchio per scatola americana Double Gang INFORMAZIONI SUL RICICLAGGIO Si consiglia ai clienti di smaltire i dispositivi usati centrali rilevatori sirene accessori elettronici ecc nel rispetto dell ambiente Metodi potenziali com prendono il riutilizzo di parti o di prodotti interi e il riciclaggio di prodotti com ponenti e o materiali DIRETTIVA RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE RAEE WEEE Nell Unione Eu