Home
File istruzioni - Italiana Sensori Presenta
Contents
1. 2 3 ELECTRICAL WIRING POWER Power 12 Vdc 10 15 Vdc MASK Anti mask output normally closed contact in standby TAMPER 24 h Antitamper output ALARM Alarm output normally closed relay in stand by 2 3 1 Visualization LED Table 2 Colore Color LED 1 Red General alarm LED LED 2 Yellow Microwave LED LED 3 VERDE Upper PIR LED LED 4 VERDE Lower PIR LED 2 3 2 Anti masking The detector is equipped with an active IR anti masking function to protect the pyroelectric sensors It emits a tampering signal within 3 minutes The output of this function is the MASK terminal block see fig 13 In a standard configuration this terminal block can be connected to a 24h active line or to a control unit input appropriately pro grammed to send fault messages When the detector identifies a masking attempt the four LEDs flash simultaneously until the masking condition is resolved To enable the correct operation of the masking detection system Anti masking allow the detector to study and analyse the environmental conditions of the area to be protected This procedure is mandatory to guarantee the correct operation of the anti masking channel Follow the procedure below 1 Make the connections to the detector terminal box leaving the dip switch set to OFF 2 Once powered close the lid and run all the flow tests requi red 3 Open the lid and set dip switch 5 to ON 4 Close the lid imme
2. itali diana ART ITEM 8031 ISR022 8031 ISR022 uani RILEVATORE VOLUMETRICO DA ESTERNO IN TRIPLA TECNOLOGIA CON ANTIMASK Manuale di installazione uso e manutenzione KI TRIPLE TECHNOLOGY VOLUMETRIC DETECTOR FOR OUTDOOR USE WITH ANTI MASK FUNCTION Installation operation and maintenance manual MADE IN ITALY Istruzioni originali INDICE i DESCRIZIONE 2 1 1 CARATTERISTICHE GENERALI iii 2 1 2 CARATTERISTICRE TEGNICHE Lu e 3 be ANENE 3 15 IDENTIFICAZIONE DELLE PARTI 4 2 INSTALLAZIONE clan 5 2 1 AVVERTENZE GENERALI 5 2 2 MONTAGGIO DEL RILEVATORE sccc ccccctvecsscsccatssecssrnasectstendesddsesviestandess 5 Zo COLLEGAMENTI ELETTRICI sie 9 2 3 1 LED idlVisualizzazione i 9 2 3 2 Antimascherament snai 9 233 Regolazione PIRZ sia 10 2 3 4 Regolazione portata Microonda n 12 2 3 5 Impostazione DIP SWITCH ia 12 2 3 6 Funzionamento IN AND wmv aiana 13 3 RICERCA DEI GUASTI E O MALFUNZIONAMENTI 14 4 MANUTENZIONE E VERIFICHE PERIODICHE iiiinna 15 4 4 PULIZIAESTERNA DEL RILEVATORE iii 15 5 SMALTIMENTO E ROTTAMAZIONE i 15 5 1 DISINSTALLAZIONE lle 15 Le informazioni riportate in questo manuale sono state compilate con cura tuttavia Italiana Sensori non pu essere ritenuta responsabile per eventuali errori e o omissioni Italiana Sensori si riserva il diritt
3. Vite di fissaggio del coperchio Pomello di regolazione PIR2 basso Elettronica e supporto con possibilit di rotazione di 150 Microinterruttore con funzione antistrappo solo se fissato con la vite A OG Staffa fissaggio a parete in acciaio Inox Staffe a U q t 2 non fornite contenute nel kit accessorio art 001805 00102AA Vite metrica M4 x 6 inox per fissaggio staffe ad U q ta 4 contenute nel kit accessorio art 001805 00102AA Viti metriche M4 x 10 inox q ta 4 contenute nel kit accessorio art 001805 00102AA Il fissaggio tra rilevatore e staffa G viene assicurato dalle due viti A In particolare la vite di fissaggio in prossimit del microinterruttore assicura anche la protezione antistrappo Nel maneggiare il rilevatore evitare di toccare le lenti di filtro sopra i sensori PIR Grey zones can not be protected the coverage of dashed zones can be obtained with rotation of internal mechanism 1 5 PARTS IDENTIFICATION Table 1 Identification Detector on wall fixing screws Cover with Fresnel lens Adjusting knob for low PIR2 150 horizontally rotating device a Antitamper micro switch only if fixed with screw A Stainless steel wall fixing bracket U Shaped bracket 2pcs not supplied available in kit 001805 00102AA Stainless Steel metric screw M4 x 6 for U brackets fixing 4pcs enclosed into kit item 001805 00102AA Stainless Steel
4. 4 MANUTENZIONE E VERIFICHE PE RIODICHE 4 1 PULIZIA ESTERNA DEL RILEVATORE Per assicurare il corretto funzionamento del rilevatore ne cessario che la lente venga mantenuta pulita Una lente non perfettamente pulita pu causare problemi di rivelazioni e o problemi alla funzione antimask Periodicit quando necessario o in condizione di sporcizia evi dente Materiale da utilizzare panno acqua senza additivi Procedura di pulizia ATTENZIONE Per rimuovere sporcizie particolar mente evidenti NON utilizzare prodotti a base di clo ro prodotti abrasivi oppure alcool 1 Pulire il coperchio e la lente con un panno inumidito con ac qua 2 Ripassare con un panno asciutto 5 SMALTIMENTO E ROTTAMAZIONE 5 1 DISINSTALLAZIONE 1 Svitare le viti che tengono fisso il coperchio frontale e rimuo verlo 2 Scollegare il rilevatore sulla morsettiera scollegare tutti i mor setti v Fig 14 3 Dividere le parti in base alla loro tipologia e smaltirle in accor do con le leggi vigenti ATTENZIONE A Non disperdere nell ambiente i componenti ed ogni altro materiale del prodotto Rivolgersi a consorzi abilitati allo smaltimento ed al riciclag gio dei materiali 4 MAINTENANCE AND CHECKS PERIODIC 4 1 CLEANING THE EXTERNAL PART OF THE DE TECTOR Keep the lens clean to guarantee proper operation of the detector A lens which is not perfectly clean may cause detection pro blems and or problems t
5. 3 Attenzione la massima distanza di copertura 18 m si ottiene solamente installando il rilevatore a 120 cm da terra Sequenza di montaggio e Effettuare 4 fori nel muro ed inserire tasselli e Passare i cavi attraverso il foro della staffa Fissare ora la staffa al muro o se su palo seguire le indicazioni di fig 5 Nel fissare la staffa al muro fare attenzione alla perpendicolarit rispetto al terreno Nel caso di fissaggio su palo procedere come illustrato in figura fissando la staffa metallica principale alle due staffe da palo opzionali Fig 5 screw B see fig 2 Important the maximum detection range 18 meters is obtained only if the installation height is 120 cm Assembly sequence e Make four holes on the wall and insert the plugs e Pass the wires through the support slot and fix the metallic support on the wall To fix the metallic support on the pole please see fig 5 Fix the metallic support on the wall perpendicularly to the ground Fix the support onto the mounting support with supplied screws Place the brackets not included around the pole and fasten using the pole locking screws e Poggiare il corpo del rilevatore sulla staffa e farlo scendere fino in fondo per far coincidere i fori di fissaggio del corpo con quelli della staffa Per ottenere il passaggio cavo forare l apposito pretaglio utilizzando un oggetto appuntito di adeguato diametro giravite o s
6. genera un segnale di manomissione entro 3 minuti L uscita dedicata a questa funzione il morsetto denominato MASK v fig 13 In una installazione tipica questo morsetto pu essere collegato ad una linea attiva 24h o ad un ingresso di centrale opportuna mente programmato per l invio di messaggi di anomalia Quando il rilevatore rileva un tentativo di mascheramento i quattro LED lampeggiano simultaneamente fino a quando permane la condi zione di mascheramento Per abilitare il funzionamento corretto della rilevazione di mascheramento Anti masking necessa rio consentire al rilevatore di studiare ed analizzare automatica mente le condizioni ambientali dell area che deve proteggere Questa procedura obbligatoria per assicurare il corretto funzio namento del canale antimascheramento La procedura da seguire la seguente 1 Effettuare i collegamenti alla morsettiera del rilevatore la sciando il dip switch in OFF 2 Dopo aver dato alimentazione chiudere il coperchio ed effet tuare tutte le prove di portata necessarie per il funzionamento desiderato 3 Riaprire il coperchio e impostare in ON il dip switch 5 4 Chiudere immediatamente il coperchio entro 10 secondi al massimo 5 Tenersi fuori dall area di copertura del rilevatore per circa 4 minuti affinch durante questo periodo non venga rilevata nessuna presenza e verificare che non vi siano oggetti nel raggio di 1 m POWER MASK TAMPER ALARM
7. 6 LED spenti LED sempre accesi 12 Adjust the microwave sensibility in relationship to the needed detection range 2 3 5 DIP SWITCHES setting chart Operation description PIR 1 PIR 2 HIGH sensitivity PIR 1 PIR 2 MEDIUM HIGH sen sitivity PIR 1 PIR 2 MEDIUM LOW sen sitivity ON ON PIR1 PIR 2 LOW sensitivity logic PIR 1 AND Alarm output active only when PIR 2 AND all three technologies detect the MW presence Note it can be used in most outdoor installations PIR 1 OR PIR 2 AND MW Output alarm active when the MW and one of the two PIR de tect a presence Note not recommended in par ticularly hostile environments PIR 1 AND PIR 2 Alarm output active when both PIRs detect a presence the MW is not managed Note the detection of the MW does not affect the performance of the detector PIR 1 OR PIR 2 OR MW Alarm output active when a sin gle technology one of the two PIRs or the MW detects a pre sence Note not suitable for outdoor applications Anti mask function Anti mask function activated deactivated LEDs off LEDs always ON 2 3 6 Funzionamento in AND Esempio di rilevamento in modalit triplo AND dip 3 e 4 in OFF 1 NO ALARM L animale viene rilevato da due delle tre tecnologie PIR basso e MW per cui l allarme NON si attiva 120 cm Fig 22 2 NO ALARM La persona viene rilevata da due delle tre tecnologie PIR alto e MW per cu
8. a della MW 24 GHz e Sensori infrarosso a doppio elemento basso consumo con filtro UV e Regolazione di precisione dei fasci del PIR inferiore sistema brevettato e Lente di Fresnel resistente ai raggi UV e Ampiezza orizzontale del fascio 85 e Escursione orizzontale della copertura di 45 e Contenitore in policarbonato anti UV e Staffa di fissaggio a parete in acciaio inox e Staffe di fissaggio a palo in acciaio inox disponibile su richiesta e Funzione Antimasking Sensibilit infrarossi regolabile e Funzione AND o OR selezionabile Translation of the original instructions original instructions in Italian CONTENTS Te DESCRIPTION 2 l 1 GENERAL PEAT URES secs tonnini ieia piein aai 2 12 TECR NICALFEATURES iti 3 lo NOCE oer 3 5 PARTS IDENTIFICA HON l 4 2 INSTALLATION Gu aiar 5 AT GENERALPRECAUTIONS o lara 5 22 MOUNTING THE DETECTOR 9 25 ELEGIRICALWVIRING Jbl 9 2031 VISUAIZAUOM LED 9 232 AMMAN 9 239 RIRZad einen 10 2 3 4 MW range adjustMent i 12 23 5 DIPSWITCHES selingchafi a iisi 12 2 3 6 AND mode Pia ia 13 3 TROUBLE SHOOTING waa AA AA aa 14 4 MAINTENANCE AND PERIODIC CHECKS s sssmasamasamasanasanasansasazasazini 15 4 1 CLEANING THE EXTERNAL PART OF THE DETECTOR 15 5 DISPOSALAND SCRAPPING iii iii nia aaa 15 o DISMANTUNG oa 15 The informations in this manual have been issued with care anyway Italiana Sensori will not be r
9. before running the coverage test the IR sensors need to be stabilised In order to obtain a real simulation free the protected area preventing more people from moving inside the same area After 30 40 seconds of quiet try to access the detection area by moving perpendicularly to the beams thus avoiding a frontal approach Check the operation of the two PIRs with the two green LEDs and the operation of the microwave with the yellow LED Run the operation test making sure to break the IR beams see fig 1 by moving perpendicularly to them Once detection has been achieved wait for at least 7 8 seconds before trying to be detected again The covered area pattern is shown in fig 1 1 4 SELECTING THE COVERAGE AREA The maximum detection range is 18 m at 120 cm from the ground with covered area of about 85 25 C 75 relative humidity Particular conditions may increase or decrease the detection range The detector can work both in AND or in OR configuration for PIRs The possible configurations are described in the paragraph of setting out the DIP switch and relative examples of installation vedere fig 22 23 24 see fig 22 23 24 Fig 1 Le zone in grigio non possono essere coperte le zone tratteggiate potranno essere coperte ruotando il meccanismo interno 1 5 IDENTIFICAZIONE DELLE PARTI Tabella 1 Part Identificazione A Viti di fissaggio del supporto rilevatore sulla staffa fissaggio a parete
10. creased WRONG INSTALLATION detector tilted upwards If the detector is not installed perpendicularly to the ground as shown operational reliability may result decreased Fig 10 MONTAGGIO NON CORRET TO Accertarsi che il rilevatore sia montato perpendicolarmente rispetto al terreno Il rilevatore 8031 ISR022 equipaggiato con speciali filtri per i disturbi dei raggi solari nei limiti del possibile co munque consigliata l installa zione evitando il sole diretto Fig 12 WRONG INSTALLATION Take care to install the detector perpendicularly to the groung 8031 ISRO22 is designed to avoid any light disturbance However too strong light as direct sunlight may cause un stable condition of detector for example direct sunlight It s recommended to avoid such type of installation 2 3 COLLEGAMENTI ELETTRICI POWER Alimentazione 12 Vcc 10 15 Vcc MASK Uscita antimask contatto normalmente chiuso a riposo TAMPER Uscita per la linea Antisabotaggio 24h ALARM Uscita allarme contatto normalmente chiuso a riposo Fig 13 2 3 1 LED di visualizzazione Tabella 2 Colore Color LED 1 ROSSO LED allarme generale LED 2 GIALLO LED della parte microonda LED 3 VERDE LED PIR 1 PIR superiore LED 4 VERDE LED PIR 2 PIR inferiore Fig 14 2 3 2 Antimascheramento Il rilevatore dotato di antimascheramento a infrarossi attivi per la protezione dei sensori piroelettrici che
11. ction 85 e Horizontal detection excursion 45 e UV resistant polycarbonate case Stainless steel wall fixing bracket Stainless steel pole fixing brackets available on request e Antimasking function e Adjustable IR sensibility e AND OR selectable function 1 2 CARATTERISTICHE TECNICHE 8031 ISR022 Consumo a 12 Vcc 20 mA max Contatti di allarme MOS FET relay 100 mA 35 V 2 Q max mascheramento Copertura rilevazione V par 1 4 Antimascheramento IR attivi Grado di protezione IP 44 contenitore Classe ambientale Classe IV EN 50131 1 Temperatura di funzionamento da a 25 C 1 55 C Dimensioni esterne LxPxA mm 81x56x189 mm Peso g 470 compreso staffe Policarbonato resistente UV Distanza di 3 18m funzionamento 1 3 AVVERTENZE Dopo aver alimentato il rilevatore attendere almeno 3 4 minuti prima di effettuare le prove di copertura i sensori infrarossi hanno bisogno di stabilizzarsi AI fine di ottenere una simulazione reale liberare la zona protetta evitando che pi persone si muovano all interno della zona stessa Dopo 30 40 secondi di quiete provare ad entrare nell area di rilevazione spostandosi perpendicolarmente ai fasci evitando quindi l avvicinamento frontale Verificare il funzionamento dei due PIR con l ausilio dei due LED verdi di segnalazione e della microonda con l ausilio del LED giallo Effettuare la prova di funzionamento facend
12. diately maximum within 10 seconds 5 Keep out of reach of detector for about 4 minutes in order that not detected any presence and pay attention that there are no objects within 1 m 2 3 3 Regolazione PIR 2 2 3 3 PIR 2 adjustment Effettuare la regolazione del PIR2 inferiore tramite la vite di Once the detector has been installed at 120 cm from the ground regolazione dopo aver installato il rilevatore a 120 cm dal suolo adjust the PIR2 lower using the adjustment screw Tacche di riferimento per le diverse portate del PIR 2 Position adjustment related to different lower PIR 2 range Fig 15 Posizione E Position E Fig 16 Posizione D Position D Fig 17 10 Posizione C Position C Fig 18 Posizione B Position B Fig 19 Posizione A Position A Fig 20 Se l oggetto in movimento risulta essere particolarmente grande per esempio un automobile c la possibilit che il rilevatore possa rilevarne la presenza anche a distanze maggiori di 18 m Quando si imposta la funzionalit del rilevatore in triplo AND Dip 3 e 4 in OFF la distanza che si ottiene tramite la regolazione del PIR 2 basso in realt la distanza massima di rilevazione del rilevatore If the object in motion is very large for example a car there is possibility that the detector can detect its presence even if it s farther than 18 m If the detector is set in triple AND Dip 3 and 4 in OFF positio
13. doesn t work 2 2 MOUNTING THE DETECTOR Installation height must be between 1 m and 1 30 m not tilted ground If medium sized animals might enter the coverage area we recommend installing the detector at a height that allows you to prevent the upper beam from detecting their presence see fig 22 23 24 Fissare la staffa di ancoraggio a muro o su palo stabile ed immune da oscillazioni e Svitare la vite B fig 2 e levare il coperchio con lente Fix the support on a wall or on a stable pole e Unscrew the B fig 2 screw an remove the front cover with lens e Fissare l unit rilevatore ad innesto TTT e Screw up the detector see fig 6 vedi fig 6 sulla staffa ed avvitare le due viti A fig 2 avendo cura di passare il cavo dei collegamenti come riportato nelle fig 4 e 5 e Effettuare le regolazioni del rilevatore agendo sul pomello di regolazione del PIR 2 inferiore basandosi sul grafico al par 2 3 3 usando il trimmer di regolazione della sensibilit della 120 cm on the support using the 2 provided screws A fig 2 passing through the connection cable as shown in the figures 4 and 5 e Liftup or take down the PIR 2 lower using the adjusting knob to choose the protected area as shown in para 2 3 3 Rotate the trimmer to adjust the MW sensibility see fig 21 e Mount the front cover fixing it with MW fig 21 e Applicare il coperchio con lente fissandolo con la vite B fig 2 Fig
14. entazione and if the voltage is between 9 5 Verificare che il Dip Switch 6 sia in and 16 Vdc posizione OFF Make sure that Dip Switch 6 is Falsi allarmi Il rilevatore non perpendicolare set to OFF al terreno False alarms The detector is not perpendicular to the ground Il PIR basso mal regolato rag giunge distanze superiori a quelle Check if the lower detection area desiderate is wider than your planning Oggetti in movimento nell area Check if there are objects in mo protetta biancheria stesa rami di vement in the detection area alberi MW adjustment is set at maxi Il trimmer della sensibilit della mum level MW al massimo No detection someti The Lower PIR is not properly A volte non rileva Errata regolazione in particolare mes adjusted del PIR basso MW adjustment is set at mini La sensibilit della MW al minimo mum level Allarmi continui Ostacoli di medie dimensioni a ri Continuous alarms of Medium sized obstacles close to dell uscita MASK dosso del rilevatore MASK output the detector Aprire il coperchio disalimentare Open the lid disconnect the de il rilevatore attendere circa 5 se tector wait about 5 seconds re condi rialimentare e chiudere il power and close the lid immedia coperchio immediatamente entro tely within 10 seconds 10 secondi Red LED blinking Verify the detector s power sup Il LED rosso lampeggia Verificare la tensione di alimenta ply zione del rilevatore 14
15. esponsible for any errors or omissions Italiana Sensori reserves the rights to improve or modify the products described in this manual at any times and without advance notice All products and production process are designed with eco compatibility criteria This product is made in Italy 1 DESCRIPTION The 8031 ISR022 outdoor detector consists of two dual PIR passive sensors and a 24 GHz microwave The particularly evolved electronics have been designed to guarantee the maximum performance in outdoor environments and at extreme temperatures The three beams are adjustable and allow to get a horizontal coverage of 170 The coverage range of the lower IR can also be adjusted vertically in order to obtain a coverage range within 3 m and 18 m The detector is also equipped with the active IR ANTI MASKING function EN 50131 1 This function has been implemented to make the 8031 ISR022 detector unassailable by those who may have access to the detector installation site during the period in which the system is disconnected It indicates any attempt to prevent its operation by blocking masking its detection field 1 1 GENERAL FEATURES e Triple technology for outdoor use e Two PIR sensors and one microwave with switching function e MW frequency 24 GHz e Infrared sensors low consumption double element and UV filter e Low PIR beam precision adjustment patented system e UV rays resistant Fresnel Lens e Horizontal beam dete
16. i l allarme NON si attiva 120 cm Fig 23 3 La persona viene rilevata da tutte e tre le tecnologie PIR basso PIR alto MW per cui si attiva lo stato di allarme ALARM 120 cm Fig 24 Attenzione le illustrazioni fanno riferimento alla modalit di funzionamento in triplo AND se si decide di utilizzare impostazioni diverse vedere par 2 3 5 DIP Switch 3 e 4 in ON si hanno allarmi anche negli esempi in fig 22 e 23 2 3 6 AND mode operation Example of detection in triple AND configuration dip 3 and 4 in OFF position 1 NO ALARM The pet is detected only by two of the three sensor elements PIR low and MW The alarm is not enabled 2 NO ALARM The body is detected only by two of the three sensor elements PIR high and MW The alarm is not enabled 3 ALARM The body is detected by the three sensor elements PIR low PIR high MW The alarm is enabled Warning the examples are referred to the triple AND set up In case of different set up see para 2 3 5 DIP Switches 3 and 4 in ON position alarms are enabled also in the previous examples see fig 22 and 23 3 RICERCA DEI GUASTI E O MALFUN 3 TROUBLE SHOOTING ZIONAMENTI trouble Soluzione trouble Solution I LED non si accendo Verificare la correttezza dei colle LEDs fail to switch on Check wiring connection no gamenti Verificare la presenza ed il valore Check the presence of current dell alim
17. imile Fig 6 Dopo aver effettuato le regolazioni del PIR 2 e della portata MW chiudere il rilevatore inserendo il coperchio dall alto verso il basso come illustrato quindi avvitarlo tramite la vite metrica in acciaio inox in dotazione Fig 7 MONTAGGIO CORRETTO Montare il rilevatore in posizione verticale e perpendicolarmente al terreno O 120 cm Fig 8 e Locate the detector body on the metallic support and slide it down then fix it using the supplied screws In order to obtain a passage for the cables break the plastic pre cut using a pointed object of appropriate diameter screwdriver or similar Adjust PIR2 and MW close the detector inserting downwards the coverage as shown in figure Fix the cover using the metric screw CORRECT INSTALLATION Position the detector vertically and perpendicularly to the ground MONTAGGIO NON CORRETTO verticalmente Se il rilevatore viene montato inclinato verso il basso la portata pu risultare ridotta rilevatore inclinato O Fig 9 MONTAGGIO NON CORRETTO verticalmente Se il rilevatore viene montato inclinato verso l alto il PIR basso non garantisce la copertura in prossimit del suolo mentre il PIR superiore copre una zona troppo alta rilevatore inclinato WRONG INSTALLATION detector tilted downwards If the detector is not installed perpendicularly to the ground as shown operational reliability may result de
18. metric screw M4 x 10 enclosed into kit item 001805 00102AA Fix the detector to the support G using the two screws A In particular the mounting screw close to the micro switch ensures also the anti tamper protection Do not touch the filter lenses on the PIR s when handling the detector Fig 2 2 INSTALLAZIONE 2 1 AVVERTENZE GENERALI Prima dell installazione verificare le seguenti condizioni e la parete non deve presentare avvallamenti o sporgenze eccessive installare il rilevatore su superfici rigide prive di vibrazioni evitare il posizionamento del rilevatore vicino a fonti di calore o alla luce diretta del sole e evitarelariflessione dell energia elettromagnetica su ampie superfici quali ad esempio specchi pareti metalliche etc e evitare di puntare il rilevatore su lampade fluorescenti o comunque di porlo nelle immediate vicinanze delle stesse e Per i collegamenti consigliabile utilizzare un cavo schermato e preferibilmente un cavo per ogni rilevatore e Separare i cavi dell impianto di allarme da quelli della rete elettrica Il rilevatore pu essere installato in ambiente esterno secondo quanto prescritto dalla normativa EN 50131 1 nella classe ambientale IV e Evitare di puntare il rilevatore verso oggetti in movimento o se ci risultasse inevitabile prestare la massima cura nelle regolazioni al fine di evitare falsi allarmi e Apporre sempre il coperchio con lente di Fres
19. n configuration the maximum distance of detection is the one setted through the Adjustment of the PIR2 11 2 3 4 Regolazione portata microonda PIR 1 2 3 4 MW range adjustment Fig 21 Si raccomanda di diminuire la sensibilit della microonda in rapporto alla distanza di copertura desiderata 2 3 5 Impostazione DIP SWITCH DIP1 DIP2 Descrizione del funzionamento PIR 1 PIR 2 sensibilita ALTA OFF PIR 1 PIR 2 sensibilit MEDIO ALTA OFF PIR 1 PIR 2 sensibilit MEDIO BASSA ON ON PIR1 PIR2 sensibilit BASSA OFF OFF PIR 1 AND PIR 2 AND MW OFF PIR 1 OR PIR 2 AND MW Logica di funziona Descrizione del funzionamento Uscita allarme attiva solo quan do tutte e tre le tecnologie rile vano la presenza Nota utilizzabile nella maggior parte delle installazioni esterne Uscita allarme attiva quando la MW ed uno qualsiasi dei due PIR rilevano la presenza Nota non consigliata in am bienti particolarmente ostili PIR 1 AND PIR 2 Uscita allarme attiva quando entrambi i PIR rilevano la pre senza non viene gestita la MW Nota la rilevazione della MW non ha influenza sulle presta zioni del rilevatore PIR 1 OR PIR 2 OR MW Uscita allarme attiva quando una sola tecnologia uno dei due PIR oppure la MW rileva la presenza Nota non utilizzabile in applica zioni esterne Funzione Antimask Funzione Antimask attivata disattivata DIP
20. nel prima di effettuare le prove di copertura senza lente il rilevatore non funziona 2 2 MONTAGGIO DEL RILEVATORE L altezza di installazione deve essere compresa tra i 100 cm min ed 130 cm max terreno non in pendenza Se nell area di copertura c la possibilit che vi sia presenza di animali di medie dimensioni si consiglia di installare il rilevatore ad una altezza tale da evitare che il fascio superiore rilevi la presenza dell animale stesso v fig 22 23 24 2 INSTALLATION 2 1 GENERAL PRECAUTIONS Before starting the installation make sure that e the wall does not have any pronounced depressions or protrusions install the detector on rigid surfaces free of vibrations e avoid to fix the detectors near to heat sources or at direct sunlight e avoid electromagnetic energy reflection on wide surfaces such as mirrors metal walls etc e avoid to fix the detector in front of fluorescent lamps or in proximity of them e Connections shielded cable is suggested and one cable per detector is preferred e Separate the alarm system cables from the mains cables The detector can be installed outdoors according to the standard EN 50131 1 in environment IV e Avoid to direct the detector towards moving objects or if impossible please take care in adjusting the detector in order to avoid false alarms e Be sure to install the cover with Fresnel lens before the detector testing Without cover the detector
21. o attenzione ad interrompere i fasci dell infrarosso vedere fig 1 spostandosi perpendicolarmente ai fasci stessi Una volta ottenuta la rilevazione occorre attendere non meno di 7 8 secondi prima di provare ad essere rilevati di nuovo Il grafico di copertura viene riportato nella fig 1 1 4 SELEZIONE DELL AREA DI COPERTURA La massima copertura di 18 metri a 120 cm dal suolo con un apertura di circa 85 in condizioni standard 25 C 75 umidit relativa Particolari condizioni ambientali possono aumentare o diminuire tale portata Il rilevatore pu lavorare sia in modalit AND che in modalit OR degli infrarossi Le possibili configurazioni sono descritte nel paragrafo di impostazione dei DIP switch e relativi esempi di installazione 1 2 TECHNICAL FEATURES 8031 ISR022 Power supply from 9 to 15 Vcc Current consumption 12 Vdc 20 MA max MOS FET relay 100 mA 35 V 20 max See par 1 4 4 Alarm masking contacts Motion detection coverage Antimasking Signal LEDs Enclosure degree of protection Active IR IP 44 Class IV EN 50131 1 Grade 3 EN 50131 1 Environmental classification Security grading Operating temperature from to Wa a iG 81x56x189 mm 470 including brackets UV resistant polycarbonate 3 18m External dimensions WxDxH mm Weight g Casing Operating range 1 3 NOTICES Once the detector has been powered wait 3 4 minutes
22. o di apportare in ogni momento e senza preavviso miglioramenti e o modifiche ai prodotti descritti nel presente manuale Italiana Sensori pone particolare attenzione al rispetto dell ambiente Tutti i prodotti ed i processi produttivi sono progettati con criteri di eco compatibilita Il presente articolo stato prodotto in Italia 1 DESCRIZIONE Il rilevatore da esterno 8031 ISR022 composto da due sensori passivi dual PIR e da una microonda a 24 GHz L elettronica particolarmente evoluta stata progettata per garantire le massime prestazioni in ambiente esterno e a temperature rigide tre fasci sono orientabili e permettono di ottenere una copertura orizzontale distribuita su 170 Il range di copertura dell infrarosso inferiore orientabile anche verticalmente e questo permette di ottenere un range di copertura compreso tra 3 m e 18 m Oltre alle funzioni di rilevazione il rilevatore dotato della funzione di ANTIMASKING ad infrarossi attivi EN 50131 1 Tale funzione stata implementata per rendere il rilevatore 8031 ISRO22 inattaccabile da quanti potrebbero avere accesso al sito dove il rilevatore installato durante il periodo in cui il sistema risulta disinserito segnala ogni tentativo di impedire il suo funzionamento bloccando mascherando il suo campo di rilevazione 1 1 CARATTERISTICHE GENERALI e Tripla tecnologia da esterno e Due sensori PIR e una microonda con funzionamento programmabile e Frequenz
23. o the anti mask function Frequency when necessary or when clearly dirty Material to be used cloth water with no additives Cleaning procedure IMPORTANT Do NOT use chlorine based or abrasive products or alcohol to remove particularly noticeable dirt 1 Clean the lid and the lens with a cloth dampened with water 2 2 Wipe with a dry cloth 5 DISPOSAL AND SCRAPPING 5 1 DISMANTLING 1 Unscrew the screws that fasten the front lid and remove it 2 Disconnect the detector disconnect all the terminals on the terminal block see Fig 14 3 Divide the parts by type and dispose of them in accordance with applicable laws IMPORTANT AN Do not dispose of the components or any other pro duct material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Italiana Sensori S a s Via Pordenone 2 00100 Roma RM tel 39 06 92928252 fax 39 06 92942586 info italianasensori it www italianasensori it