manuale di installazione, uso e manutenzione

image

Contents

1. SECTION 4 INSTALLATION CONNECTION CLIENT The client is the person activity or the society that has bought or hired the apparatus and intends to utilise the machinery for its intended use USER OPERATOR The User or Operator is the actual person that has been authorised by the client to utilise the apparatus TECHNICIAN Defined as the person who has followed a relevant specific course of study and so is able to understand the dangers derived from the use of the apparatus and in turn due to this are capable of solving major dilemmas 4 2 Safety Regulations 1 The Manufacturer declines any responsibility for failure to respect the Safety Regulations and the prevention as described below Furthermore the manufacturer declines any responsibility for damage caused by the improper use of the unit and or modifications carried out without proper authorisation e L installazione deve essere effettuata da personale specializzato e Nelle operazioni di installazione usare un abbigliamento idoneo e antinfortunistico ad esempio occhiali guanti ecc come indicato da norma 686 89 CEE e successive e Durante l installazione operare in assoluta sicurezza ambiente pulito e libero da impedimenti e Rispettare le leggi in vigore nel Paese in cui viene installata la macchina relativamente all uso e allo smaltimento dell imballo e dei prodotti impiegati per la pulizia e la manutenzione della macchina non
2. 5 2 Collegamento SIL monofase con regolatore di velocita RCS pag 17 5 3 Collegamento SIL trifase con autotrasformatore VT pag 18 SEZIONE 6 CONTROLLI PRIMA DELL AVVIAMENTO 6 1 Controlli prima dell avviamento pag 19 SEZIONE 7 MANUTENZIONE ORDINARIA 7 1 Controlli mensili pag 19 7 2 Controlli annuali pag 20 SEZIONE 8 LOCALIZZAZIONE DEI GUASTI 8 1 Localizzazione dei guasti pag 21 SEZIONE 9 SMANTELLAMENTO 9 1 Smantellamento pag 21 SECTION PRESENTATION 1 1 Manual presentation page7 1 2 Unit identification page7 SECTION 2 TECHNICAL CHARACTERISTICS 2 1 General characteristics page8 2 2 Accessories page8 2 3 Unit dimensions page9 2 4 Electrical characteristics page9 SECTION 3 TRANSPORTATION 3 1 Packing pagel0 3 2 Transportation 10 3 3 Checklist pagel0 3 4 Storing pagel0 SECTION 4 INSTALLATION amp CONNECTION 4 1 Definitions page 11 4 2 Safety regulations page 11 4 3 Preliminary operations page 12 4 4 Choosing installation position page 12 4 5 Duct connection page 13 4 6 Electrical connection page 13 4 7 Accessories connection RCS VT page 14 SECTION 5 ELECTRICAL SCHEMES 5 1 Machine cabinet page 16 5 2 SIL single phase connection to RCS speed regulator page 17 5 3 SIL three phase connection to VT auto transformer page 18 SECTION 6 PRE START UP CHECKS 6 1 Pre start up checks page 19 SECTION 7 ORDINARY MAINTEN
3. VT auto autotrasformatore VT transformer I COLLEGAMENTI A CURA DELL INSTALLATORE SONO INDICATI A TRATTEGGIO THE CONNECTIONS TO BE CARRIED OUT BY THE INSTALLER ARE SHOWN BY THE DOTTED LINE Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 19 SEZIONE 6 CONTROLLI PRIMA DELL AVVIAMENTO AVA 6 1 Controlli prima dell avviamento Prima di avviare l unit controllare quanto segue 1 Collegamento dei canali 2 Connessione del cavo di terra 3 Serraggio di tutti i morsetti elettrici SEZIONE 7 MANUTENZIONE ORDINARIA DAA PRIMA DI INTRAPRENDERE QUALSIASI OPERAZIONE MANUTENTIVA ACCERTARSI CHE LA MACCHINA NON SIA E NON POSSA CASUALMENTE O ACCIDENTALMENTE ESSERE ALIMENTATA ELETTRICAMENTE E QUINDI NECESSARIO TOGLIERE L ALIMENTAZIONE ELETTRICA AD OGNI MANUTENZIONE dovere del committente eseguire sull unit tutte le operazioni di manutenzione Solo personale addetto precedentemente addestrato e qualificato pu eseguire le operazioni di manutenzione Se l unit deve essere smontata proteggere le mani con dei guanti da lavoro 7 1 Controlli mensili 7 1 1 Verifica della girante Accertarsi che la girante sia pulita In caso contrario pulirla mediante soffiaggio di aria compressa e comunque in modo da non danneggiarla 7 1 2 Verifica dell apparecchiatura elettrica Verificare tutta l apparecchiatura elettrica ed in particolare il perfet
4. acoustically insulating material obtain an EXTREMELY SILENT operation The series consists of eight models With its different combinations of fan dimensions speeds and power supply the series cover capacity of 200 7000 m h with static pressures up to 500 Pa Fans are double inlet centrifugal type with statically and dynamically balanced impellers reducing noise and vibrations to a minimum The high useful static pressure available allow installation of duct even of long stretches permitting the extraction or delivery of air in several locations Ed 06 2005 Sal aa INSTALLATION amp MAINTENANCE MANUAL PAGE 6 SEZIONE 1 PRESENTAZIONE 1 1 Presentazione manuale pag 7 1 2 Identificazione macchina pag 7 SEZIONE 2 CARATTERISTICHE TECNICHE 2 1 Caratteristiche generali pag 8 2 2 Accessori pag 8 2 3 Dimensioni unita pag 9 2 4 Caratteristiche elettriche pag 9 SEZIONE 3 TRASPORTO 3 1 Imballaggio pag 10 3 2 Movimentazione e trasporto pag 10 3 3 Controllo al ricevimento pag 10 3 4 Stoccaggio pag 10 SEZIONE 4 INSTALLAZIONE E MESSA IN SERVIZIO 4 1 Definizioni pag 11 4 2 Norme di sicurezza pag 11 4 3 Operazioni preliminari pag 12 4 4 Scelta del luogo d installazione pag 12 4 5 Collegamento ai canali pag 13 4 6 Collegamenti elettrici pag 13 4 7 Installazione accessori RCS VT pag 14 SEZIONE 5 SCHEMI ELETTRICI 5 1 Quadro macchine pag 16
5. counter panelling e The SIL series use double inlet centrifugal electrical fans with forward blade curved impellers The high pressures available allow the use of ducts even of long lengths e The SIL series has dynamically and statically balanced impellers reducing noise and vibrations to a minimum The motors are external rotor type except SIL 450 6T with built in thermal protection contact The SIL series has anti vibrators to attenuate the transmission of any vibration placed between the supporting structure and the fans e The working temperatures must be between 20 C and 40 C e The inspection and possible removal of the fans is from above as shown in the diagram 2 2 Accessories e Single phase electronic regulator RCS e Three phase auto transformer VT Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 9 2 3 Dimensioni unita 2 3 1 Dimensioni modelli SIL 130 50 90 2 3 Unit dimensions 2 3 1 SIL model dimensions Quadro elettrico 120x80 Electric box 120x80 50 MODELLO DIMENSIONI DIMENSIONS MODEL A mm B mm C mm D mm E mm SIL 160 400 400 450 160 275 SIL 200 400 400 450 200 250 SIL 250 400 400 450 250 250 SIL 315 550 550 550 315 300 SIL 355 550 550 550 355 300 SIL 400 650 650 650 400 378 SIL 450 6M amp 6T 750 750 750 450 430 2 4 Caratteristiche elett
6. dalla direttiva 89 391 CEE e successive modifiche Evitare rotazioni senza controllo 3 3 Controllo al ricevimento Al ricevimento dell unit Vi preghiamo di effettuare un controllo di tutte le parti al fine di verificare che il trasporto non abbia causato danneggiamenti i danni eventualmente presenti devono essere comunicati al vettore apponendo la clausola di riserva nella bolla di accompagnamento specificandone il tipo di danno 3 4 Stoccaggio In caso di stoccaggio prolungato mantenere le macchine protette dalla polvere e lontano da fonti di vibrazioni e di calore La ditta costruttrice declina ogni responsabilita per danneggiamenti dovuti a cattivo scarico o per mancata protezione dagli agenti atmosferici SECTION 3 TRANSPORTATION UU 3 1 Packin The ventilation unit and accessories are packed in cardboard boxes this packing should remain intact until the moment of construction The materials that are not required for technical motives are supplied in fitted packing fixed externally and internally to the unit 3 2 Transportation For the lifting and transportation of the unit use adequate equipment according to the 89 391 CEE regulations and successive modifications Avoid rotation without control 3 3 Checklist Upon reception of the apparatus we suggest that a complete control is carried out to verify that the unit is intact and complete and no damage has been sustained during transport Any ev
7. massima in A Tensione di alimentazione in V Frequenza di alimentazione Hz Numero di fasi indicato con Ph lt Data di produzione Codice della macchina SECTION I PRESENTATION 1 1 Manual presentation This manual informs and describes the transport installation use and maintenance of the SIL ventilating units produced by LMF Srl The user will find the information which is normally helpful for a correct and safe installation of the unit The non respect of the items described in this manual or inadequate SIL unit installation may cause annulment of the guarantee of the machine given by the manufacturer The manufacturer will not be held responsible for any direct or in direct damages caused by an incorrect installation or installation of the unit by non qualified or non authorised personnel Verify at the purchase that that machine is in perfect condition and complete Any complaints must be given in writing within 8 days from the receipt of the goods 1 2 Unit identification The SIL ventilation units are supplied with an identification plate which shows the following E The manufacturer s address CE indication Model Serial number Maximum absorbed current in A Power supply voltage in V Power supply frequency Hz Number of phases indicated in Ph Production date The code of the machine Ed 06 2005 Sane 21988 INSTALLATIO
8. 7 AME m UME E MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION OPERATION amp MAINTENANCE MANUAL UNITA VENTILANTI SILENZIATE NOISELESS FAN BOXES SERIE SIL SERIES SIL Ed 06 2005 Ed 06 2005 SIMBOLOGIA SYMBOLOGY AVVERTENZA ATTENTION PERICOLO DANGER PERICOLO RISCHIO DI SCOSSE ELETTRICHE HIGH RISK OF ELECTRIC SHOCK ATTENZIONE SOLO PERSONALE AUTORIZZATO ATTENTION AUTHORIZED PERSONNEL ONLY Ed 06 2005 Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 5 INTRODUZIONE Gentile Cliente Le unit ventilanti della serie SIL sono composte da cassonetti ventilanti che con un opportuno spessore di materiale fonoassorbente garantiscono una ESTREMA SILENZIOSITA di funzionamento La serie si compone di otto modelli con ventilatori direttamente accoppiati Con diverse combinazioni di diametro girante velocit di rotazione e alimentazione la serie copre un campo di portate da 200 a 7000 m h con pressioni statiche fino a 500 Pa Gli elettroventilatori sono a doppia aspirazione giranti bilanciate staticamente dinamicamente per ridurre al minimo le vibrazioni e il rumore Le elevate pressioni statiche utili permettono il montaggio di canalizzazioni anche di lunga tratta consentendo l estrazione o l immissione dell aria su pi locali INTRODUCTION Dear Customer The SIL series are composed of ventilating units which with a suitable layer of
9. ANCE 7 1 Monthly maintenance page 19 7 2 Yearly maintenance page 20 SECTION 8 TROUBLESHOOTING 8 1 Fault finding page 21 SECTION 9 SCRAPPING 9 1 Scrapping page 21 Ed 06 2005 Lane M M S Wa l MANUALE INSTALLAZIONE E MANUTENZIONE PAG 7 SEZIONE 1 PRESENTAZIONE 1 1 Presentazione manuale Questo manuale riporta le informazioni e quanto ritenuto necessario per il trasporto l installazione l uso e la manutenzione delle unit ventilanti SIL prodotte dalla ditta LMF Srl L utente trovera quanto normalmente utile conoscere per una corretta installazione in sicurezza di tali unita La mancata osservanza di quanto descritto in questo manuale o una inadeguata installazione delle unita SIL possono essere causa di annullamento della garanzia che la Ditta Costruttrice da alle macchine La Ditta Costruttrice inoltre non risponde di eventuali danni diretti e o indiretti dovuti ad errate installazioni o per danni causati dalle unita installate da personale inesperto e non autorizzato Verificare all atto dell acquisto che la macchina sia integra e completa Eventuali reclami dovranno essere presentati per iscritto entro 8 giorni dal ricevimento della merce 1 2 Identificazione macchina I cassonetti ventilanti SIL sono dotati di una targhetta di identificazione che riporta Indirizzo del Costruttore Marcatura CE Modello Numero di matricola Corrente assorbita
10. N amp MAINTENANCE MANUAL PAGE 8 SEZIONE 2 CARATTERISTICHE TECNICHE 2 1 Caratteristiche generali e La struttura realizzata in lamiera zincata con contropannellatura interna forata e L isolamento acustico garantito da uno spessore di 50 mm di materiale fonoisolante lana di vetro interposto nella contropannellatura e La serie SIL monta elettroventilatori centrifughi a doppia aspirazione con girante a pale avanti Le elevate pressioni statiche disponibili permettono il montaggio di canali anche di lunga tratta e Le giranti sono bilanciate dinamicamente e staticamente per ridurre al minimo le vibrazioni e il rumore I motori sono a rotore esterno eccetto SIL 450 6T con incorporato contatto termico per la protezione dello stesso e Perla serie SIL fra struttura portante e ventilatore sono interposti degli antivibranti per attenuare la trasmissione di eventuali vibrazioni e temperatura di esercizio deve essere compresa fra i 20 C e i 40 C e L ispezione e l eventuale estrazione del ventilatore avviene dall alto come illustrato in figura 2 2 Accessori e Regolatore elettronico monofase RCS e Autotrasformatore trifase VT SECTION 2 TECHNICAL CHARACTERISTICS 2 1 General characteristics e Galvanized steel structure with reinforced internal drilled counter panelling e Acoustic insulation is guaranteed by a 50 mm thickness of acoustic insulation material fibreglass wool placed in the
11. SN INSTALLATION amp MAINTENANCE MANUAL PAGE 16 SEZIONE 5 SCHEMI ELETTRICI SECTION 5 ELECTRICAL SCHEMES 5 1 Quadro macchine 5 1 Machine cabinet 5 1 1 SIL monofase 5 1 1 SIL single phase AUSILIARIO AUXILIARY MARCIA START 5 1 2 SIL trifase a singola velocit 5 1 2 SIL three phase single speed SCHEMA AVVOLGIMENTO WINDING DIAGRAM COLLEGAMENTO ALLA MORSETTIERA CONNECTOR CONNECTION COLLEGAMENTO A TRIANGOLO COLLEGAMENTO A STELLA Ed 06 2005 SANE CE AS N UL MANUALE INSTALLAZIONE E MANUTENZIONE PAG 17 5 2 Collegamento SIL monofase con regolatore 5 2 SIL single phase connection to RCS speed di velocit RCS regulator 5 2 1 Collegamento diretto 5 2 1 Direct connection i d VENTILATORE FAN I COLLEGAMENTI A CURA DELL INSTALLATORE SONO INDICATI A TRATTEGGIO THE CONNECTIONS TO BE CARRIED OUT BY THE INSTALLER ARE SHOWN BY THE DOTTED LINE 5 2 1 Collegamento ottimale 5 2 1 Optimal connection VENTILATORE FAN I COLLEGAMENTI A CURA DELL INSTALLATORE SONO INDICATI A TRATTEGGIO THE CONNECTIONS TO BE CARRIED OUT BY THE INSTALLER ARE SHOWN BY THE DOTTED LINE Ed 06 2005 INSTALLATION amp MAINTENANCE MANUAL PAGE 18 5 3 Collegamento SIL trifase con 5 3 SIL three phase connection to
12. ch osservare quanto raccomanda il produttore di tali prodotti e Prima di mettere in funzione l unit controllare la perfetta integrit dei vari componenti e dell intero impianto e Evitare assolutamente di toccare le parti in movimento o di interporsi tra le stesse e procedere con i lavori di manutenzione e di pulizia se prima non stata disinserita la linea elettrica e La manutenzione e la sostituzione delle parti danneggiate o usurate deve essere effettuata solamente da personale specializzato e seguendo le indicazioni riportate in questo manuale e Qualified personnel must out the installation e During the installation operation use protective clothing for example glasses gloves etc as indicated by 686 89 CEE and successive regulations e During the installation operate in absolute security pollution free air and in an area free of obstructions e Respect the regulations in force in the country in which the apparatus is being installed Specifically relative to its use and to the disposal of packing and products used for the cleaning and maintenance of the unit Respect the recommendations given by the producers of such products e Before placing in function the unit check the perfect connection of the various components and the internal parts of the system e Avoid at all costs human contact with moving parts and contact with the parts themselves e Do not commence with servicing or clea
13. e Connect the unit to an efficient power point using the correct screws as supplied with the unit Ed 06 2005 INSTALLATION amp MAINTENANCE MANUAL PAGE 14 4 7 Installazione accessori RCS VT 4 7 1 Regolatore di velocit RCS Adatto per l installazione a parete permette la regolazione della velocit e quindi della portata d aria delle unit con alimentazione monofase A seconda della corrente assorbita dal motore e possibile scegliere fra tre taglie di regolatori RCS 1 5A RCS 3 0A RCS 5 0A Sul pannello di comando sono presenti interruttore acceso spento manopola regolazione continua della velocit Installazione e montaggio 1 Svitare le quattro viti frontali Togliere il coperchio 3 Fissare a muro la basetta con le 2 viti in dotazione Posiz a circa 1 5m dal pavimento 4 Effettuare i collegamenti elettrici 5 Riposizionare il coperchio e riavvitare le quattro viti Viti frontali Front screws 110 Caratteristiche tecniche 75 4 7 Accessories installation RCS VT 4 7 1 Speed regulator RCS Suitable for wall installation it allows speed regulation and therefore single phase unit airflow capacity According to motor absorbed power it is possible to choose between three regulator sizes RCS 1 5A RCS 3 0A On the control panel there are On off switch J Continuous speed regulation knob RCS5 0A Installation mounting 1 Unscrew the
14. entual damage revealed must be communicated to the carrier demonstrating the reserve clause within the transport documents specifying the type of damage 3 4 Storing In case of long term storage the apparatus must be kept free from dust and away from areas susceptible to heat and vibration The manufacturer declines any responsibility for any damage as a result of negligence or lack of protection from atmospheric agents Ed 06 2005 SL MANUALE INSTALLAZIONE E MANUTENZIONE PAG 11 SEZIONE 4 INSTALLAZIONE E MESSA IN SERVIZIO UJ 4 1 Definizioni UTENTE L utente la persona l ente o la societ che ha acquistato o affittato la macchina e che intende usarla per gli scopi concepiti UTILIZZATORE OPERATORE L utilizzatore o operatore amp la persona fisica che stata autorizzata dall utente a operare con la macchina PERSONALE SPECIALIZZATO Come tali si intendono quelle persone fisiche che hanno conseguito uno studio specifico e che sono quindi in grado di riconoscere i pericoli derivati dall utilizzo di questa macchina e possono essere in grado di evitarli 4 2 Norme di sicurezza 1 La Ditta Costruttrice declina qualsiasi responsabilita per la mancata osservanza delle norme di sicurezza e di prevenzione di seguito descritte Declina inoltre ogni responsabilita per danni causati da un uso improprio delle unita e o da modifiche eseguite senza autorizzazione
15. four front screws Remove the cover 3 Fix the base to the wall using the two screws supplied about 1 5 m above floor level 4 Carry out the electrical connections 5 Replace the cover and tighten the four screws pa 82 Viti fissaggio muro Wall fixing screws Fori fissaggio coperchio Cover fixing hole Technical characteristics Alimentazione 230 10 V c a 50 60 Hz Power supply 230 10 Va c 50 60 Hz Campo di regolazione 40 a 100 V max Regulation range 40 up to 100 V max Regolazioni Commutatore manuale ON OFF Rea Manual ON OFF switch Manopola regolazione velocit Speed regulation knob RCS 1 5 1 5 A RCS 1 5 15A Corrente nominale RCS 3 0 30 A Nominal current RCS 3 0 3 0A RCS 5 0 5 0 A RCS 5 0 5 0 A RCS 1 5 3 0 A RCS 1 5 3 0A Corrente massima RCS 3 0 5 0 A Maximum current RCS 3 0 5 0A RCS 5 0 7 5 A RCS 5 0 75A Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 15 4 7 2 Auto trasformatore VT Permette la regolazione a 5 gradini della velocit nelle unit dotate di motore trifase Sul pannello di comando Spia presenza tensione Manopola regolazione della velocit Installazione L installazione dovr essere eseguita esclusivamente da personale qualificato che prima di avviare l unit dovr verificare Che i dati della rete di corrispondenti a quelli di targa C
16. haracteristics of the unit fans A mistaken calculation of the ducting will cause power loss or the intervention of any eventual devices present on the system e In order to attenuate the noise level the use of air cased ducts is recommended e To avoid the transmission of machine vibrations into the environment it is advised to fit an anti vibration joint between the fans and Ducts The electrical continuity must be guaranteed between the Ducts and the apparatus via an earth cable 4 6 Electrical connections AMA Before commencing any operation insure that the general power supply has been isolated e Qualified personnel according to the supplied schemes must carry out the electrical connections at the control panel e Insure that the voltage and the frequency shown on the technical plate correspond to the connecting power supply Follow the connection of the unit and its accessories using adequate cabling for the power used and respecting the country regulations The dimension of the cabling must be sufficient to support a voltage drop in start up phase inferior to 3 of the nominal e For the general power supply of the unit and its accessories the use of adapters multiple plugs and extension leads is to be avoided e It is the responsibility of the installer to insure that the installation of the unit is as close as possible to the mains power supply or sufficiently close to protect the electrical parts
17. he tutti i data riguardanti il carico da applicare al regolatore rientrino nei parametri di terga specificati nelle caratteristiche tecniche dell apparecchio alimentazione siano Caratteristiche tecniche 4 7 2 Auto transformer VT Allows unit speed regulation in five steps with three phase motors On the control panel are X Voltage indication light A Five step speed regulation knob Installation The installation must be carried out only by qualified personnel who before installation must verify The power supply line data correspond to those given on the data plate A All data regarding the load to witch the regulator is to be applied are within the parameters of data plate specified in the apparatus technical characteristics Spia tensione 300 Technical characteristics Alimentazione 400 10 V c a neutro 50 60 Hz Power supply 400 10 V a c neutral 50 60 Hz Regolazione Selettore a 5 posizioni Regulations Five step selector Corrente nominale 5A Nominal current SA Corrente massima TA Maximum current 7A Segnalazioni Marcia Indications Start Protezione IP 55 Protection IP33 1 posizione 90 V 1 step 90 V 2 posizione 140 V 2 step 140 V Tensione uscita 3 posizione 180 V Output voltage 3 step 180 V 4 posizione 230 V 5 posizione 400 V 4 step 230 V 5 step 400 V Ed 06 2005 i
18. li sostanze acide aggressive e corrosive che possono danneggiare i vari componenti in maniera irreparabile e Prevedere uno spazio libero minimo come indicato in figura al fine di rendere possibile l installazione e Spare parts must correspond to the requirements specified by Manufacturer e Incare of dismantling of the unit respect the anti pollution regulation in force N B The installer and the user of the apparatus must take into account and solve problems connected with any other type of risk that may occur to the unit For example risks derived from the entrance of foreign bodies or risks due to the presence of flammable or toxic gas e Check the perfect condition of the various components of the unit e Control that contained within the packing there are the installation accessories and documentation e Transport the packed section as close as is possible to the intended place of installation e Do not place tools or weight on top of the packed unit 4 3 Preliminary Operations 4 4 Choosing installation position N e Position the unit on a solid structure that will not vibrate and is capable supporting the weight of the machine e Do not position the unit in an area in which flammable gases acidic or corrosive substances are present They may damage various components in an irreparable manner e Allow a minimum amount of free space as indicated in the figure This permits ease of installation a
19. nd ela manutenzione ordinaria e straordinaria maintenance H E E E E E E E E E E E E El E E E E E E E E E E E E E E E E E H H H H H p EE H I H H H si E 100 100 MODELLO MODEL A SIL 160 300 SIL 200 250 400 SIL 315 355 550 SIL 400 650 SIL 450 750 Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 13 4 4 5 Collesamento ai canali AMA IMPORTANTE SI FA DIVIETO DI METTERE IN FUNZIONE L UNITA FSM SE LE BOCCHE DEI VENTILATORI NON SONO CANALIZZATE O PROTETTE CON RETE ANTI INFORTUNISTICA A NORMA UNI 9219 E SUCCESSIVE e I canali devono essere dimensionati in funzione dell impianto e delle caratteristiche aerauliche dei ventilatori dell unit Un errato calcolo delle canalizzazioni causa perdite di potenza o l intervento di eventuali dispositivi presenti sull impianto e Per attenuare il livello di rumorosit si consiglia di utilizzare canali coibentati e Per evitare di trasmettere le eventuali vibrazioni della macchina in ambiente consigliato interporre un giunto antivibrante fra le bocche ventilanti e i canali Deve comunque essere garantita la continuit elettrica fra canale e macchina tramite un cavo di terra 6 Collegamenti ele
20. ning of the unit before the unit has been disconnected from the main supply e The maintenance and the substitution of damaged or consumed parts must be carried out only by specialised personnel following the indications found within this manual Ed 06 2005 I ISI INSTALLATION amp MAINTENANCE MANUAL PAGE 12 e Le parti di ricambio devono corrispondere alle esigenze definite dal Costruttore e In caso di smantellamento dell unit attenersi alle normative antinquinamento previste N B L installatore e Putilizzatore nell uso dell unit devono tenere conto e porre rimedio a tutti gli altri tipi di rischio connessi con l impianto Ad esempio rischi derivanti da ingresso di corpi estranei oppure rischi dovuti al convogliamento di gas pericolosi infiammabili o tossici ad alta temperatura e Verificare la perfetta integrit dei vari componenti dell unit e Controllare che nell imballo ci siano contenuti gli accessori per l installazione e la documentazione e Trasportare la sezione imballata il pi vicino possibile al luogo di installazione e Non sovrapporre attrezzi o pesi sull unit imballata 4 3 Operazioni preliminari 4 4 Scelta del luogo di installazione AN e Posizionare l unit su di una struttura solida che non causi vibrazioni e che sia in grado di sopportare il peso della macchina e Non posizionare l unit in locali in cui sono presenti gas infiammabi
21. o Sense of rotation inverted Velocit di rotazione troppo bassa Rotation speed too low Pressione i insufficiente e Portata superiore a quella richiesta Insufficient pressure Airflow higher than required e Senso di rotazione invertito Sense of rotation inverted Calo di prestazioni Perdite nei condotti dopo un periodo MAM Dreh Air leakage in the duct isf te di e Ostruzioni nei condotti Duct blockage soddisfacente di performance funzionamento Sporcizia nella girante Il motore non gira e Manca l alimentazione La girante bloccata Collegamenti elettrici allentati Dirt on the impeller Assorbimento di potenza eccessivo Effettivo punto di lavoro spostato verso alte portate e basse pressioni The motor does not work No power supply Impeller blocked Loose electrical connection Difetti meccanici Girante squilibrata a causa di usura o di depositi di polvere Strisciamento della girante sulla coclea dovuto a deformazioni Surriscaldamento od usura anomala dei cuscinetti per difetto d origine o per cattivo bilanciamento Actual working condition wass i characterized by too high airflow absorption and too low pressure Unbalanced impeller caused by wear or dust deposit Mechanical defects Impeller touching the casing by deformations Warm bearings caused by balancing defect Verificare sulla morsettiera del motore che il collegamento sia co
22. polvere sporcizia o altre impurit Verificare che il sistema funzioni senza vibrazioni o rumori anomali e che l ingresso del circuito di ventilazione se presente non sia ostruito con conseguente possibilit di surriscaldamento degli avvolgimenti Verificare che la chiocciola del ventilatore sia libera da sporcizia e qualunque corpo estraneo 7 2 Yearly checks Check all the electrical equipment in particular the connections tightness Check the tightness of all the nuts bolts and flanges which may have been loosened by vibrations Check there are no traces of dust dirt or other impurities on the motor Check that it operates without vibrations or abnormal noise that the ventilation circuit inlets if present are not obstructed causing consequently the possibility of motor winding overheating Check the fan scroll is free of dirt and foreign objects Ed 06 2005 MANUALE INSTALLAZIONE E MANUTENZIONE PAG 21 SEZIONE 8 LOCALIZZAZIONE DEI GUASTI U 8 1 Localizzazione dei guasti SECTION 8 TROUBLESHOOTING U 8 1 Fault findin ANOMALIA PROBABILE CAUSA FAULT CAUSES Condotti aria parzialmente ostruiti Air duct partially blocked Portata e Velocita di rotazione troppo bassa Rotation speed too low E e Pressione statica superiore a quella Insufficient airflow Static pressure higher than insufficiente a richiesta required Senso di rotazione invertit
23. riche 2 4 Electrical characteristics 2 4 1 Modelli SIL 2 4 1 SIL models Corrente max N velocita Grado di Classe di AR Potenza Alimentazion Rumorosit Modelli all ase assorbita ven eis Poli protezione isolamento Rae Norea adl Mader Aeneon Max absorbed N of fan Poles Protection Insulation Les current speeds grade class w A IP V Ph Hz dB A SIL 160 2M 45 0 66 2 2 20 B 230 1 50 43 SIL 200 2M 90 0 85 1 2 54 F 230 1 50 46 SIL 250 2M 140 1 4 1 2 32 F 230 1 50 44 SIL 315 4M 184 1 90 1 4 55 F 230 1 50 47 SIL 355 4M 420 3 60 1 4 55 F 230 1 50 53 SIL 400 4M 550 4 60 1 4 55 F 230 1 50 59 SIL 450 6M 515 5 00 1 6 55 F 230 1 50 45 SIL 450 6T 1100 7 80 2 6 20 B 400 3 50 60 Massimo livello di pressione sonora netta ad un metro dall unit Sound net pressure max level at 1 m far from unit Ed 06 2005 SUA Bf Y Y al Ny M NT INSTALLATION amp MAINTENANCE MANUAL PAGE 10 SEZIONE 3 TRASPORTO U 3 1 Imballaggio Le unita ventilanti e i loro accessori sono inseriti in scatole di cartone che dovranno rimanere integre fino al momento del montaggio I materiali che non sono stati installati per esigenze tecniche vengono forniti imballati con involucro idoneo fissato all interno o esterno dell unita stessa 3 2 Movimentazione e trasporto Per la movimentazione utilizzare in funzione del peso mezzi adeguati come previsto
24. rretto ed inoltre che la tensione corrisponda a quella di targa SEZIONE 9 SMANTELLAMENTO 9 1 Smantellamento A fine utilizzo i cassonetti SIL andranno smaltiti nel rispetto delle normative vigenti nel paese d installazione I materiali che compongono le unit sono e Acciaio Lana di vetro e Rame e Check that all the connector connections are correct and that the voltages correspond to those of the data plate SECTION 9 SCRAPPING 9 1 Scrapping At the end of SIL unit use it must e scrapped in compliance with the regulation in force in the country of installation The unit is composed of the following material Steel e Fibreglass wool e Copper e Rubber Ed 06 2005 OTE OTES Ed 06 2005 Sal ARO NY Y M F Sede stabilimento Via Paradiso 1 B 36040 MELEDO DI SAREGO VI ITALY Tel 39 0444 821279 r a Fax 39 0444 820323 Ed 06 2005
25. to serraggio di tutte le connessioni elettriche SECTION 6 PRE START UP CHECKS AWA 6 1 Pre start up checks Before starting the unit check the following 1 Duct connection 2 Earth cable connection 3 All the electrical connection have been tightened SECTION 7 ORDINARY MAINTENANCE BEFORE CARRIYNG OUT ANY MAINTENANCE OPERATION MAKE SURE THE MACHINE IS NOT ONLY AT REST OR CAN BE ACCIDENTALLY TURNED ON THEREFORE IT IS NECESSARY TO DISCONNECT THE POWER SUPPLY EVERY TIME MAINTENANCE IS CARRIED OUT It is purchaser s responsibility to carry out al unit maintenance operations Only suitable personnel previously trained and qualified may carry out maintenance operations If the unit has to be dismantled protect hand with working gloves 7 1 Monthly checks 7 1 1 Wheel check Check the wheel is clean If this is not the case clean it using compressed air in such a way not to damage the wheel 7 1 2 Electrical equipment check Check all the electrical apparatus and in particular the tightness of electrical connections Ed 06 2005 AUS MEU INSTALLATION amp MAINTENANCE MANUAL PAGE 20 7 2 Controlli annuali Verifica di tutta l apparecchiatura elettrica ed in particolare delle connessioni elettriche Verifica del serraggio di tutti i bulloni dadi e flangie che le vibrazioni avrebbero potuto allentare Verificare che il motore non presenti tracce di
26. ttrici NUDA Prima di iniziare qualsiasi operazione assicurarsi che la linea di alimentazione generale sia sezionata e I collegamenti elettrici ai quadri di comando devono essere effettuati da personale specializzato secondo gli schemi forniti e Assicurarsi che la tensione e la frequenza riportate sulla targhetta corrispondano a quelle della linea elettrica di allacciamento Eseguire il collegamento dell unit e di tutti i suoi accessori con cavi di sezione adeguata alla potenza impegnata e nel rispetto delle normative locali La loro dimensione deve comunque essere tale da realizzare una caduta di tensione in fase di avviamento inferiore al 3 di quella nominale e Per l alimentazione generale dell unit e degli accessori non consentito l uso di adattatori prese multiple e o prolunghe e E dovere dell installatore prevedere il montaggio il pi vicino possibile all unit di un sezionatore dell alimentazione quanto necessario per la protezione delle parti elettriche e Collegare l unit ad una efficace presa di terra utilizzando l apposita vite inserita nell unit stessa 4 6 Duct connection AMA IMPORTANT IT IS IMPORTANT NOT TO PLACE IN OPERATION THE UNIT FSM IF THE MOUTHS OF THE FANS ARE NOT DUCTED OR NOT PROTECTED BY A SAFETY NET ADHERING WITH REGULATION UNI 9219 OR SUCCESSIVE e The Ducts must be the correct dimension based on the functions of system and the air diffusion c