Home

jm-gm-jmm manuale uso e manutenzione serie jm-gm

image

Contents

1. Ex ATEX 94 9 EC group II class 3D motors for zone 22 the purchaser is responsible for taking adequate technical and organizational measures and for assessing all possible explosion hazards so as to protect the health and safety of workers in potentially explosive areas Directive 99 92 EC As soon as the motor arrives check to make sure that it is not faulty or damaged in any way Before operating the motor check the plate data read carefully the instruction manual supplied with the motor and make sure that the motor is suitable for the required use Please contact us if the application will be used with an inverter 2 SPECIFICATIONS 2 1 General specifications JM GM JMM series JM IEC 56 160 0 09 18 5 kW 2 4 6 8 poles three phase GM IEC 160 450 4 900 kW 2 4 6 8 poles three phase JMM IEC 56 100 0 09 2 2 kW 2 4 poles single phase Standard asynchronous three phase electric motor with short circuited squirrel cage rotor for general purposes in industrial applications enclosed externally fan cooled with IC 411 cooling method thermal insulation class F class B motor over temperature class with standard power class B or B F for the remaining three phase and single phase motors Motor designed for continuous duty S1 at rated voltage and frequency JM and GM motors are suitable for operation with inverters O It is forbidden to use the motor in places with an aggressive atmosphere and where there is a
2. interrut tore magnetotermico non sufficiente Per ottenere avviamenti dolci con basse correnti di spunto si pu adottare l avviamento a tensione ridotta per partenze a vuoto o con carichi ridotti utilizzare l avviamento Y A o con soft starters mentre per avviamenti a pieno carico e nelle applicazioni con elevati momenti d inerzia utilizzare l inverter Funzionamento con inverter i motori JM e GM sono adatti al funzionamento con inverter valori limiti tensione alimentazione U lt 500 V picchi di tensione Unax lt 1 000 V gradienti di tensione dU dt lt 1 kV us Per tensione di alimentazione gt 500 V interpellarci L utilizzo dell inverter richiede delle precauzioni l entit Pee JM GM JMM 1 GENERAL RECOMMENDATIONS 1 1 Safety warning IN Improper use of the motor incorrect installation removal of the protections elimination of the safety devices and negligent maintenance may cause serious damage to persons and things Thus the motor must only be handled installed commissioned serviced and repaired by qualified personnel in accordance with IEC364 Dangers electric motors have under tension parts moving parts and parts that reach temperatures exceeding 50 Any operation on the motor must be performed when the motor itself is at a standstill and disconnected from the mains power supply Disconnect any auxiliary equipment and take all measures to prevent sudden starts The capacitor of single phase
3. 4 2 6 Output power depending on altitude iii 4 2 7 Three phase motor power supplies differing from the rated values4 2 8 Structure and assembly positions ccccciiri ii 5 3 INSTALEATION hall aiar 5 oi Moccia 5 3 2 Connection OF aCcessori S rioni 6 Zoe Tightening 10 0068 7 4 MAINTENANCE 111 rire 7 4 1 Periodical motor maintenance iii 7 4 2 lubrication of the bearingS i 8 5 JM JMM SPARE PARTS nr rire 9 6 GM SPARE PARTS scccsrecserecserscserscnersenersenecsenscseeresenresenrens 9 A N Important notice texts and data of this manual are not binding and we reserve the right to change them without previous notice For any further technical information please do not hesitate to contact our technical dept Disassembly of the motor or replacement of its parts automatically voids the warranty on the purchased motor Please note that the motors in this manual comply with the following Community Directives Low Voltage directive 2006 95 CEE The motors of this manual comply with the requirements of the directives and show on the nameplate CE brand Electromagnetic Compatibility directive 2004 108 CEE Not compulsory on the products of this manual Compliance to the directive is responsibility of the builder of the machine We remind that electric motors are components which shal
4. 9 Morsettiera Cable gland 10 Vite fissaggio scatola morsettiera Terminal box 11 Scatola morsettiera 3 4 7 14 15 3 16 19 Terminal box fastening screw 12 Statore Terminal box 13 Scudo lato opposto comando re aS Stator 14 Guarnizione scatola morsettiera ee Shield on side opposite control 15 Anello di sollevamento Sioa Terminal box seal 16 Molla di precarico 1 Lifting ring 17 Ventola NSIN Preload spring 18 Anello di tenuta pag ie Sa Fan 19 Tirante per IMB5 F k Retention ring 20 Tirante per IMB14 I GI Jacking screw for IMB5 21 Flangia IMB14 i PS AS a a Jacking screw for IMB14 22 Flangia IMB5 32 I o IMB14 flange 23 Anello elastico di sicurezza N AT a IMB5 flange 24 Copriventola 25 rl L Safety spring ring 25 Cuscinetto Fan cover 26 Vite fissaggio copriventola Bearings 27 Rotore 31 30 Fan cover fastening screw 28 Vite fissaggio piede per IMB3 6 Rotor 29 Carcassa Stand fastening screw for IMB3 30 Piede per IMB3 Housing 31 Scudo lato comando per IMB3 Stand for IMB3 32 Albero 5 Shield on control side for IMB3 33 Condensatore JM 63 80 Vie EN N N JMM 666 100 Shaft 33 Capacitor 14 TNS 9 33 Fig 5 1 Draw 5 1 6 RICAMBI GM 6 GM SPARES 1 Linguetta 1 Key 2 Condotto lubrificazione lato comando 2 Lubrication duct on control side 3 Ingrassatore 3 Lubricator 4 Scatola morsettiera 4 Terminal box 5 Guarnizione scatola morsettiera 5 Terminal box seal 6 Vite fissaggio coprimorsettiera 6 Terminal box
5. richiesta al nostro ufficio tecnico La garanzia sul motore acquistato viene automaticamente a decadere qualora il motore subisca lo smontaggio e la sostituzione di parti ft Ricordiamo che i motori del presente manuale sono conformi alle se guenti Direttive Comunitarie Direttiva Bassa Tensione 2006 95 CEE motori del presente ma nuale sono conformi alla direttiva e riportano in targa il marchio CE Direttiva Compatibilit Elettromagnetica 2004 108 CEE Non ob bligatoriamente applicabile ai prodotti di questo manuale La responsabi lit della conformit alla direttiva a carico del costruttore della macchina Ricordiamo inoltre che il motore elettrico un componente che non deve essere posto in servizio prima di essere installato in una macchina o sistema completo resa e dichiarata conforme alle disposizioni della Diret tiva Macchine 2006 42 CEE rev 00 s seipee OPERATING MANUAL JM GM JMM SERIES Fi ASYNCHRONOUS ELECTRIC MOTORS GM 160 450 GB 1 GENERAL RECOMMENDATIONS 1rrr11r111r1r 10011111 2 bi SV 2 Lx VER anelli 2 Lo Ca tion QUANG ASSCHIDNNG ie 2 2 SPECIFICATIONS siscciccisniccaccscettesencannsdecnivsasndactsenubeeatauenvetes 3 2 1 General specifications wssossarcnaioaxsssnvrnnesniedseneiasscicsacdermentsbonaesnentorees g 22 Motor TOSI IN CANON lia 3 2 3 Name Dili 3 ZL Ao 4 2 5 Output power depending on ambient temperature
6. risk of explosion 2 2 Motor identification Esempio JM 100La 4 B3 Example JM 100 L a 4 B3 Tipo motore Altezza d asse mm Lunghezza carcassa Lunghezza pacco N poli Codice IM forma costruttiva Type of motor Shaft height mm Interasse fori fissaggio quota B statore N poles e tipo d installazione Length of the frame Distance between the Length of stator IM code type of construction JM JM 63 160 i centre lines of the fixing holes B dimension unit 2 4 6 8 and mounting arrangement GM GM 160 450 JMM JMM 56 100 S corta short M media medium a B3 B5 B14 i it L lunga long ii B35 B34 2 3 Targa 2 3 Name plate Mese e anno di costruzione eventuale numero di matricola Eventuale classe di efficienza Numero delle fasi Tipo motore grandezza numero poli designazione forma costruttiva Massa del motore solo se gt di 30kg Classe di isolamento Grado di protezione Servizio Capacit condensatore serie JMM Eventuali esecuzioni speciali Collegamento delle fasi Tensione nominale Frequenza nominale Corrente nominale Potenza nominale Velocit nominale Fattore di potenza OONOODOOBRWDND xe ne T XX st LD a NO I A rev 00 Fig 2 1 Draw 2 1 1 Month and year of manufacture and serial number if possible 2 Efficiency class if possible 3 Number of phases 4 Type of motor size number of poles designation mounting type 5
7. 0 1 1 19 0 95 1 05 0 84 0 79 0 63 400 60 8 3 7 440 11 12 gt 095 1 092 092 0 84 V 4 2 460 12 1 2 093105 1 096 0 92 Nom 480 1 2 1 2 1 1 1 1 1 Tensione d alimentazione sconsigliata per impieghi gravosi e funzio namento prolungato del motore ll motore pu funzionare con tale alimentazione ma non si devono avere avviamenti a pieno carico la potenza richiesta non deve superare il valore nominale La sovratemperatura del motore pu risultare maggiore 2 Il motore pu funzionare con tale alimentazione ma non si devono avere avviamenti a pieno carico P 4 1 Power supply voltage not recommended if the motor is subjected to heavy duty use or long periods of continuous duty The motor can function with this type of power supply but must not be started at full load The power demand must not exceed the rated value The motor s over temperature may be higher 2 The motor can function with this type of power supply but must not be started at full load rev 00 JM GM JMM 2 8 Forme costruttive e posizioni di montaggio Le forme costruttive previste sono IM B3 IM B5 IM B14 e forme combinate IM B35 B3 B5 e IM B34 B3 B14 motori possono funzionare anche nelle corrispondenti forme costruttive ad asse verticale Le forme costruttive e le posizioni di montaggio sono riportate in tabella Tab 2 5 Nella serie JM 56 160 e JMM 63 100 possibile montare i piedi sui tre lati della car cassa a
8. 00 2100 4750 6000 7250 2750 200 2500 5000 6500 7700 1850 4500 5750 7100 2500 225 2250 4800 6000 7450 1500 4300 5400 6900 2250 250 2000 4650 5300 7250 1150 4150 4750 6600 2000 280 2000 4300 5000 6900 1150 3800 4250 6400 2000 315 1200 3000 4800 5500 500 2100 4000 5000 1200 355 700 2300 4300 5250 220 1600 3750 4800 700 355X 350 1900 4100 5000 100 1750 3500 4500 700 400 350 1600 3900 4800 100 1100 3100 4300 350 450 1300 3500 4500 800 2700 4000 Dimezzare la quantita di grasso lato opposto accoppiamento 50 Hz 60 Hz g Poli Poles Poli Poles Poli Poles 4 6 8 2 4 6 8 2 4 8 5450 7000 8300 2600 5000 6200 7500 13 5250 6750 8000 2100 4750 6000 7250 18 5000 6500 7700 1850 4500 5750 7100 20 4800 6000 7450 1500 4300 5400 6900 23 7650 5300 7250 1150 4150 4750 6600 26 4300 5000 6900 1150 3800 4250 6400 26 37 3900 5750 7200 500 3500 5100 6200 37 45 3650 5250 6500 220 3000 4700 5900 45 60 1900 4100 5000 250 1750 3500 4500 54 86 3200 4800 6200 250 2800 4300 5300 54 81 2750 4500 5800 1750 4000 4600 93 Halve the quantity of grease on the side opposite the coupling 1 Valido per grassi al litio di buona qualit e temperature di lavoro non superiori a 90 C albero motore orizzontale e carichi normali Dimez zare i valori di tabella per applicazioni con albero motore verticale Per temperature di lavoro superiori ai 90 C dimezzare i valori di tabella per ogni 15 C di aumento di temper
9. 1 ambient air temperature 15 to 40 maximum altitude 1000 m above sea level power supply at the rated voltage and frequency values tolerated maximum voltage variation 5 Consider a further 5 for the maximum and minimum power supply limits e g a 230 400 V motor is suitable for mains voltage values up to 220 380 V and 240 415 V Also consult Tab 2 4 and the relative notes 2 5 Output power depending on ambient temperature 25 30 40 45 50 55 60 1 07 1 00 0 95 0 90 0 85 0 80 2 6 Output power depending on altitude 0 1 000 1 500 2 000 2 500 3 000 3 500 4 000 0 97 093 0 89 0 85 0 80 0 74 2 7 Three phase motor power supplies differing from the rated values please contact us if special voltage or frequency values are required Important the efficiency of a motor may drop if it is powered with different voltage frequency values from the rated ones Fattori di correzione nominale Alternative supply Corrective factors GELES tisi i requenza Tensione Voltage T T 50 H Frequency v n j aaa S Hz diff A Y diff kW min A Nm A Nm 50 4 3 380 5 0 0 95 1 05 1 0 96 0 90 4 3 415 3 8 0 95 1 05 1 1 04 1 08 A Y 20 6 380 20 8 0 95 1 05 084 0 79 0 63 230 400 60 7 9 440 8 3 0 95 1 0 92 0 92 0 84 V V 4 3 460 4 2 0 95 1 05 1 0 96 092 Nom 1 1 1 1 50 5 0 380 1 1 0 95 1 05 1 0 95 0 90 3 8 415 1 1 0 95 1 05 1 1 04 1 08 A 20 8 38
10. JM GM JMM MANUALE USO E MANUTENZIONE SERIE JM GM JMM MOTORI ELETTRICI TRIFASI JM 56 1 AVVERTENZEGENERALI nre ieri 2 1 1 Avvertenze sulla SICUFEZZa i 2 les PICEVIMENO a 2 1 3 Avvertenze sull installaziONEe u 2 2 CARAITTERISTICHE ioziannini nen nea n 3 2 1 Caratteristiche generali o 3 2 2 Identificazione motore La 3 20 TG e E a ei 3 2 4 Caratteristiche generali di funzionamento n 4 2 5 Potenza resa in funzione della temperatura ambiente 4 2 6 Potenza resa in funzione dell altitUdine in 4 2 7 Alimentazione motore trifase diversa dai valori nominali 4 2 8 Forme costruttive e posizioni di montaggio 5 3 INSTALLAZIONE nnmnnn 5 3 1 Collegame nt MOlOre cirie 5 3 2 Collegamento accessori ttn trtrtr tnn nnn nennen nerenin 6 33 Goppis di serraggio sssri srian enaena E AEAEE RENESANSES 7 4 MANUTENZIONE T 4 1 Manutenzione periodica sso canina pria 7 4 2 Lubrificazione cuscinetti lano 8 5 RICAMBI JM JMM cccccesseecesseeeesneeeenseecenseesenneeseeneeses 9 6 RICANBIGM acciai 9 Avvertenze importanti tutte le descrizioni e i dati riportati nel se guente manuale non sono impegnativi e ci riserviamo il diritto di modificali senza darne preavviso Per particolari informazioni tecniche si prega di farne
11. Weight of motor only if gt 30kg 6 Insulation class 7 Protection class 8 Duty 9 Capacitor capacitance JMM series 10 Special mounting types if applicable 11 Phase connection 12 Voltage rating 13 Rated frequency 14 Current rating 15 Rated power 16 Rated speed 17 Power factor Pos SS seipee 2 4 Caratteristiche generali di funzionamento servizio continuo S1 temperatura aria ambiente 15 C 40 C altitudine massima pari a 1 000 m s l m alimentazione a tensione e frequenza nominali variazione massima di tensione ammessa 5 Per i limiti massimo e minimo di alimentazione considerare un ulteriore 5 es un motore a 230 400 V idoneo per tensioni nominali di rete fino a 220 380 V e 240 415 V Consultare anche Tab 2 4 e relative note 2 5 Potenza resa in funzione della temperatura ambiente Tab 2 2 Tab 2 2 Temperatura aria ambiente C Ambient air temperature C P Py 2 6 Potenza resa in funzione dell altitudine Tab 2 3 Tab 2 3 Altitudine s l m m Altitude a s I m P Py 1 00 2 7 Alimentazione motore trifase diversa dai valori nominali per tensioni o frequenze speciali contattarci eC Attenzione il rendimento di un motore pu diminuire quando viene alimentato a valori di tensione frequenza diversi da quelli nominali Tab 2 4 Tab 2 4 Alimentazione Alimentazione alternativa JM GM JMM 2 4 Ratings continuous duty S
12. a macchina utilizzatrice quando un senso di rotazione contrario a quello desiderato pu causare danni a persone e o cose si consiglia di togliere la linguetta dall estremit dell albero per evitare la sua violenta fuoriuscita Per modificare il senso di rotazione nei motori trifase sufficiente invertire due fasi di alimentazioni della linea mentre per i motori monofase occorre cambiare la disposizione dei ponticelli presenti in morsettiera seguire lo schema di collegamento presente sul lato interno del coprimorsettiera Messa a terra le parti metalliche del motore che normalmente non sono sotto tensione devono essere collegate a terra utilizzando l apposito morsetto contrassegnato posto all interno della scatola morsettiera utilizzare un cavo di sezione adeguata rev 00 Or IM v5 IM 1011 IM v36 gt IM 2031 ON IM V6 IM 1031 SS sepee 2 8 STRUCTURE AND ASSEMBLY POSITIONS The versions available are IM B3 IM B5 IM B14 and combined structures IM B35 B3 B5 and IM B34 B3 B14 The motors can also function in the corresponding vertical shaft configurations The mounting types and assembly positions are given in the table Tab 2 5 On JM series JM56 160 and JMM 63 100 it is possible to mount the feet on the three sided of the casing this allows to put the terminal box on the desired side tighten properly the screw Mez B orizzontale hrizontal A A Codice montaggio Mounting cod
13. and if the supports are accessible The vacant space inside the bearing must be completely filled with fresh grease while only 30 to 50 of the space in the support must be filled There must not be too much grease in the space around the bearing as this could lead to a local temperature increase which would ruin both the grease and the bearing take care to prevent dirt from being introduced into the bearing or support along with the grease If the supports are inaccessible the grease can be completely replaced by means of the lubricator Unscrew the drain plug in the lower part of the support and top up until all the old grease has been pushed out When possible top up the grease whilst the motor is running This operation must always be carried out in safe conditions to prevent the support from being filled with too much grease The fill plug can be tightened on once a balanced tempera ture has been obtained It is advisable to install automatic systems to simplify the operation if the bearings must be lubricated very frequently Regular lubrication is essential for bearing life and thus for the operation of the motor itself Always use good quality mineral oil based Lithium grease Intervallo di lubrificazione h Relubrication interval h Lato opposto acc Non drive end Grasso Grease Motor 50 Hz 60 Hz Poli Poles Poli Poles 2 4 6 8 2 4 6 8 160 3250 5450 7000 8300 2600 5000 6200 7500 3250 180 2750 5250 6750 80
14. atura Temperatura massima di lavoro relativa a grasso al Litio con olio di base minerale pari a circa 110 C Importante in caso di smontaggio e rimontaggio di componenti del motore ove sia presente mastice e o silicone di protezione garantire lo stesso livello di protezione al momento del ri assemblaggio P 8 1 Valid for good quality lithium grease and operating temperatures of not more than 90 C horizontal drive shaft and normal loads Halve the values in the table for applications with a vertical drive shaft If the operating temperature exceeds 90 C halve the values in the table for every 15 C of temperature increase Maximum operating temperatu re with regard to Lithium grease with mineral based oil i e about 100 C Important if motor components are disassembled or re assembled in places where protective cement or silicone has been applied remember to guarantee the same degree of protection when the parts are re assembled rev 00 JM GM JMM 5 RICAMBI JM JMM 5 JM JMM SPARES 1 Linguetta 1 Key 2 V ring JM 56 2 V ring 3 Tirante per IMB3 3 Jacking screw for IMB3 4 Guarnizione coperchio scatola morsettiera JM 90 160 4 Terminal box cover seal 5 Vite fissaggio morsettiera 5 Terminal box fastening screw 6 Vite fissaggio coprimorsettiera 6 Terminal box cover fastening 7 Coprimorsettiera screw 8 Pressacavo 5 6 7 8 9 10 11 12 13 Terminal box cover
15. che il connettore femmina con relativo schema per il collegamento Prima del collegamento verificare le caratteristiche riportate sulla targhetta adesiva di identificazione ft Consigli utili all installazione utilizzare cavi schermati con connessione a terra devono essere posi zionati separatamente dai cavi di potenza Installare la scheda di controllo il pi vicino possibile all encoder e il pi lontano possibile all eventuale inverter quando non possibile scherma re in modo adeguato l inverter P 6 3 2 Connection of accessories Connection of thermal protections Terminals installed inside the motor s terminal box These protections require a dedicated relay or release device at the motor purchaser s charge Check the specifications on the sticker that identifies the type of protection prior to connection gi WARNING failure to connect the thermal probes when applicable will void the warranty with which the motor is provided PT 100 temperature sensor connection resistance thermometer Comply of standard DIN IEC 751 Check the specifications on the sticker that identifies the type of protection prior to connection PT 100 sensors require a special device in order to be used at the motor purchaser s charge Winding three PT 100 installed in the winding one per phase Terminals installed inside the motor s terminal box Bearings a PT 100 installed in the bearing support control side side oppo
16. cover fastening screw 7 Pressacavo 7 Cable gland 8 Vite fissaggio morsettiera 8 Terminal box fastening screw 9 Morsettiera 9 Terminal box Coprimorsettiera 11 Guarnizione coprimorsettiera 10 Terminal box cover 11 Terminal box cover seal 12 Vite fissaggio scatola morsettiera 5 12 Terminal box fastening screw 13 Rotore 13 Rotor 14 Golfare 3 14 Eyebolt 15 Statore 15 Stator 16 Scudo lato opposto comando 2 16 Shield on side opposite control 17 Tappo 17 Plug 18 Condotto lubrificazione lato oppo A 18 Lubrication duct on side sto comando opposite control 19 Ventola 19 Fan 20 Condotto lubrificazione lato co 20 IMB5 lubrication duct on mando IMB5 control side 21 Flangia interna bloccaggio cus EE 21 Internal bearing locking netto lato opposto comando i eee flange on side opposite 22 Flangia esterna bloccaggio cusci __ _ _ 43 D control pei lato opposto _ Bs go 22 External bearing locking 23 Anello elastico di sicurezza ali ____ DAR i flange on side opposite 24 Linguetta bloccaggio ventola 41 e ANZ control 25 Anello di tenuta 23 Safety spring ring 26 Anello elastico di sicurezza 24 Fan locking key 27 Cuscinetto lato opposto coman 40 39 38 37 36 Fig 5 2 i 2 33 25 32 31 30 25 Retention ring do Ig 9 AMG 26 Safety spring ring 28 Flangia esterna bloccaggio cuscinetto lato comando 27 Bearing on side opposite control 29 Flangia interna bloccaggi
17. e Grandezza Sise 56 180 280 359 160 250 315 450 Codice Verticale Code vertical Lp IM V1 5 IM 3011 See IM V15 1 abii IM 1001 IM V3 IM 3031 3 A IM V18 J IM 3611 ae IM V19 5 IM 3631 Possible Consult SEIpee motors 1 Motors with stands 2 Motors with flange through holes 3 Motors with flange threaded holes 3 INSTALLATION 3 1 Motor connection ge Make sure that the power supply voltage corresponds to the electrical data on the data plate before making the electrical connections Make the connections as indicated in the wiring diagrams on the sheet inside the terminal box Use cables with adequate sections to prevent overheating or excessive voltage drops on the motor s terminals Three phase motor pay attention to the connection in the terminal box and to the one shown on the motor s data plate The minimum voltage refers to the A connection the maximum voltage to the Y connection Star delta starting can only be obtained when the mains voltage corresponds to the value of A Direction of rotation it is advisable to check the motor s direction of rotation before it is coupled to the user machine The wrong direction of rotation could cause damage to persons and things you are advised to remove the spline from the end of the shaft to prevent it from springing out in a violent manner To change the direction of rotation of a three phase motor just switch tw
18. eck the motor s foundation and make sure that the machine to which the motor is connected is correctly balanced Check the tension of any belts excessively taut belts sensibly redu ce the life of the motor s bearings and can cause the shaft end to break Check the condition of the shaft seals and grease them periodically as these components function in contact with moving parts and wear out very quickly Once worn they must be replaced with components identical to the original ones Check the condition of the bearings The bearings installed in the JM and JMM series must be simply replaced at the end of their working life The bearings installed in the GM series need to be lubricated at regular intervals the frequency is indicated on the label on the motor Bearing life varies considerably and depends on the type of load and number of starts to which the motor is subjected It also depends on the temperature and degree of humidity in the work environment Excessive noise usually means that the bearings need to be replaced If the motor has been recently commissioned the first thing to do is to check the coupling correct any alignment errors and check the tension of any belts If the bearings continue to be noisy it means that they are already damaged and must be replaced Take great care to prevent the windings from being damaged when the bearings are being replaced and the shaft with rotor is removed from the stator Use a pres
19. elle eventuali cinghie Se i cuscinetti continuano ad essere rumorosi significa che sono gi stati compromessi e occorre sostituirli Durante la sostituzione dei cuscinetti quando si estrae l albero con rotore dallo statore occorre fare molta attenzione a non danneggiare gli avvolgimenti Per il montaggio dei cuscinetti utilizzare una pressa con adeguato manicotto appoggiato all anello interno oppure preriscaldare il cuscinetto stesso a circa 80 C e porlo in sede Assicurarsi che gli anelli interni siano correttamente appoggiati agli spallamenti dell albero e che i cuscinetti sostituiti siano dello stesso tipo o equivalenti a quelli originali Si consiglia di sostituire sempre le tenute sull albero rev 00 1 Tightening torque hexagonal nuts terminal block electrical connection 2 Tightening torque fixing screws of the motor parts shields flanges feet terminal box fan cover earth terminal 4 MAINTENANCE 4 1 Periodical motor maintenance To be carried out in conditions of total safety motor at a standstill and disconnected from the mains power supply Make sure that the entire cooling circuit housing air inlet from the fan side and forced ventilation fan if applicable is free from dust oil and any machining residue so as to prevent the motor from overheating and the normal cooling cycle from being impaired Make sure that the motor operates without vibrations or abnormal noise lf vibrations are noted ch
20. etta adesiva che identifica il tipo di protezione PT 100 necessitano di una apposita apparecchiatura per es sere utilizzati a carico dell acquirente del motore Avvolgimento tre PT 100 inseriti nell avvolgimento uno per fase Terminali posti all interno della scatola morsettiera motore Cuscinetti un PT 100 inserito nel supporto cuscinetto lato comando lato opposto comando Terminali posti all interno di una scatola di derivazione solidale alla carcassa del motore Collegamento scaldiglia anticondensa Terminali posti all interno della scatola morsettiera motore Prima del collega mento verificare le caratteristiche riportate sulla targhetta adesiva che iden tifica il tipo di protezione verificare i dati di alimentazione La scaldiglia non deve essere alimentata durante il funzionamento del motore Collegamento servoventilatore assiale Terminali di alimentazione posti all interno di una scatola morsettiera ausilia ria solidale al copriventola Prima del collegamento verificare le caratteristi che riportate sulla targhetta adesiva di identificazione verificare i dati di alimentazione fe Importante verificare che il senso di rotazione del ventilatore trifase corrisponda a quello indicato dalla freccia posta sul copriventola in caso contrario invertire due delle tre fasi di alimentazione Collegamento encoder Cavetto di collegamento munito di connettore maschio di tipo militare fissato al motore Viene fornito an
21. i e agenti corrosivi Dopo lunghi periodi di giacenza a magazzino si consiglia di verificare la resistenza di isola mento tra gli avvolgimenti e verso massa con apposito strumento in cor rente continua 500V A Durante e immediatamente dopo la misura presente sui morsetti una tensione pericolosa i morsetti non devono essere toccati Per avvolgimenti nuovi il valore misurato non deve essere inferiore a 10 MQ con l avvolgimento a temperatura di 25 C Valori inferiori sono normalmente indice di presenza di umidit negli avvolgimenti in tal caso vanno essiccati 1 3 Avvertenze sull installazione A Per funzionamenti con temperatura diversa da 15 40 C e ad altitudini superiori ai 1 000 m interpellateci Non consentito l im piego in luoghi con atmosfere aggressive con pericolo di esplo sione Sistemare il motore in modo che si abbia un ampio passaggio d aria dal lato della ventola insufficiente circolazione d aria compromette lo scambio termico Evitare la vicinanza con altre fonti di calore tali da influenzare la temperatura sia dell aria di raffreddamento che del motore per irraggiamento Eventuali fori scarico condensa devono essere rivolti verso il basso per permettere lo scarico Quando possibile proteggere il motore dall ecces sivo irraggiamento solare la temperatura del motore potrebbe aumentare eccessivamente dalle intemperie IM V1 e derivate necessario proteg gere il motore con un tettuccio para
22. l fine di avere la scatola morsettiera sul lato desiderato avvitare correttamente i bulloni di fissaggio Tab 2 5 Tab 2 5 IEC 600034 7 V verticale vertical Grandezza Sise Codice Orizzontale 56 11801280 355 Code Horizontal 160 250 315 450 IM B3 IM 1001 IM B35 2 IM 2001 IM B34 IM 2101 IM B5 IM 3001 IM B6 IM 1051 IM B7 IM 1061 IM B8 IM 1071 Ec 20000 tp Possibile Consultare Se pee motori 1 Motoricon piedi 2 Motori con flangia fori passanti 3 Motori con flangia fori filettati IM B14 IM 3601 3 INSTALLAZIONE 3 1 Collegamento motore A Prima di effettuare l allacciamento elettrico assicurarsi che l alimenta zione corrisponda ai dati elettrici riportati in targa Eseguire il collegamento secondo gli schemi indicati nel foglio contenuto all interno della scatola morsettiera Utilizzare cavi di sezione adeguata in modo da evitare un surriscaldamento e o eccessiva caduta di tensione ai morsetti del motore Motore trifase fare attenzione al collegamento esistente in morsettiera e a quello riportato sulla targa del motore il voltaggio minimo riferito al collegamento a A il voltaggio massimo a Y L avviamento stella triangolo possibile solo quando la tensione di rete corrisponde al valore a A Senso di rotazione consigliabile verificare il senso di rotazione del motore prima dell accoppiamento all
23. l not be started for duty unless installed on a machine or complete system which must comply and must be declared to comply with the Machine directive 2006 42 CEE P 1 SS sepee 1 AVVERTENZE GENERALI 1 1 Avvertenze sulla sicurezza Un uso improprio del motore un installazione non corretta la rimozione delle protezioni l eliminazione dei dispositivi di sicurezza la carenza di manutenzione possono causare gravi danni a persone e cose Pertanto deve essere movimentato installato messo in servizio curato e riparato esclusivamente da personale qualificato secondo IEC364 A Pericoli motori elettrici presentano parti poste sotto tensione parti in movi mento parti con temperature superiori a 50 C Qualsiasi intervento sul motore deve avvenire sempre quando fermo e scollegato dalla rete di alimentazione Scollegare eventuali equipaggiamenti ausiliari ed eliminare ogni possibilit di avvia mento improvviso Nei motori monofase il condensatore di esercizio pu rimanere carico mantenendo sotto tensione la morsettiera motore 1 2 Ricevimento Verificare che il motore corrisponda a quanto ordinato e che non abbia subito danneggiamenti durante il trasporto Non si pu mettere in servizio un motore danneggiato A golfari eventualmente presenti nella carcassa servono al solleva mento del solo motore Gi Per l eventuale giacenza in magazzino il luogo deve essere coper to pulito asciutto privo di vibrazion
24. motors may remain loaded thus keeping the motor s terminal box live 1 2 On receipt Make sure that the motor is the same as the one ordered and that it has sustained no damage during transport A damaged motor cannot be used A The eyebolts on the housing are designed for lifting the motor only eC If the motor remains in stock store it in a sheltered clean dry place free from vibrations and corrosive agents If the motor remained in stock for a long period it is advisable to check the insulation resistance between the windings and towards earth with the relative d c instrument 500V A While the measurement is being taken and immediately afterwards some of the terminal carry dangerous voltages and mustn t be touched In case of new winding with a winding temperature of 25 the value measured mustn t be lower than 10 MQ Lower values usually denote the presence of humidity in the winding in this case let them dry 1 3 Caution during assembling A Please contact us if the motor must operate at a different tempera ture from 15 40 C or at an altitude of more than 1 000 m It is forbidden to use the motor in places with an aggressive atmosphere where there is a risk of explosion The motor must be positioned so that air is free to pass around the fan side Insufficient air circulation will obstruct the heat exchange Do not install the motor near other heat sources that could affect the temperature of both the cooli
25. ng air and the motor itself Holes for draining off condensation must point downwards so as to allow the fluid to flow out When possible protect the motor against excessive exposure to the sun the temperature of the motor could increase too much inclement weather protect the motor with the rainproof cover when IM V1 and deriving versions are required and splashing water seal the terminal box and cable inlet with sealing cement Foundation must be well sized to ensure that the assembly is stable Couplings tolerance H7 is recommended for the hole of the parts keyed to the end of the shaft clean and lubricate the surfaces before coupling so as to prevent seizures Always use the relative jacking screws pullers during the assembly and disassembly operations so as to prevent the motor bearings from being damaged Never use a hammer or mallet Joints and pulleys should be heated to 60 80 prior to assembly Direct coupling make sure that the drive shaft is aligned with that of the driven machine Belt drives make sure that the shaft of the motor is parallel to the shaft of the driven machine that the pulley overhangs to the smallest possible extent and that the belt tension is unable to impair the life of the bearings or break the drive shaft The motors are balanced with a half key To prevent vibrations or imbalances the transmission components must be correctly balanced before they are coupled For duty with a high number of starts
26. nte il grasso per mezzo dell ingrassatore Si svita il tappo di scarico posizionato nella parte inferiore del supporto e si esegue il rabbocco affinch tutto il grasso esausto sia uscito dallo scarico Quando possibile eseguire il rabbocco con il motore in rotazione Operazione da effettuare sempre in condizioni di sicurezza per evitare di immettere all interno del supporto una quantit eccessiva di grasso Una volta raggiunta la temperatura di equilibrio si avvita il tappo di scarico Con intervalli di lubrificazione molto frequenti consigliamo di applicare sistemi automatici che semplificano molto l opera zione La lubrificazione regolare necessaria alla vita dei cuscinetti e quindi al funzionamento del motore stesso Si raccomanda l uso di grasso al Litio con base olio minerale di buona qualit Tab 4 1 Tab 4 1 Lato accoppiamento Drive end JM GM JMM 4 2 lubrication of the bearings Procedure for re lubricating non shielded bearings If the bearings must be re lubricated at intervals of less than once every six months indicative frequency all the grease must still be completely replaced after 2 or 3 top ups at most If the bearings must be re lubricated at intervals of more than once every six months indicative frequency all the grease must be completely replaced every six months When the old grease is replaced it is advisable to remove all the old grease and to re lubricate the bearing by h
27. o cuscinetto lato comando 28 External bearing locking flange on control side 30 Cuscinetto lato comando 29 Internal bearing locking flange on control side 31 Anello elastico di sicurezza 30 Bearing on control side 32 Molla di precarico GM160 355 31 Safety spring ring 33 Flangia IMBS 32 GM160 355 preload spring 34 Copriventola 33 Flange IMB5 35 Vite fissaggio copriventola 34 Fan cover 36 Morsetto di terra esterno GM315 450 35 Fan cover fastening screw 37 Carcassa 36 GM315 450 external earth terminal 38 Scudo lato comando IMB3 37 Housing 39 Vite fissaggio scudo IMB3 lato comando 38 Shield on control side for IMB3 40 Tappo scarico lubrificante 39 IMB3 shield fastening screw on control side 41 Vite fissaggio flangia esterna bloccaggio cuscinetto 40 Lubricant drain plug 42 Albero 41 External bearing locking flange fastening screw 42 Shaft rev 00 Peg NOTE NOTES JM GM JMM rev 00
28. o da evitare che il motore si surriscaldi per l impedimento del normale ciclo di raffreddamento Controllare che il motore funzioni senza vibrazioni n rumori anomali Se ci sono vibrazioni controllare la fondazione del motore e l equilibratura della macchina accoppiata Verificare la tensione di eventuali cinghie una tensione elevata riduce sensibilmente la durata dei cuscinetti del motore pu causare anche la rottura dell estremita dell albero Verificare lo stato delle tenute sull albero ed ingrassarle periodica mente perch tali componenti lavorano a contatto con le parti in movimen to e si usurano velocemente Una volta usurate vanno sostituite utiliz zando componenti identici agli originali Verificare lo stato dei cuscinetti cuscinetti montati nella serie JM e JMM vanno semplicemente sostituiti al termine della loro vita cuscinetti montati nelle serie GM necessitano di lubrificazione ad intervalli regolari vedere etichetta sugli intervalli posta sul motore La durata dei cuscinetti varia molto a seconda dei tipi di carichi e di avviamenti che si applicano al motore e dipende anche dalle temperature e dall umidit dell ambiente di lavoro L eccessiva rumorosit indica di solito la necessit di sostituire i cuscinetti Se la messa in funzio ne stata realizzata da poco occorre innanzi tutto controllare l accoppia mento provvedere a correggere gli errori di allineamento o verificare la tensione d
29. o of the mains power phases while in single phase motors you must change the positions of the jumpers in the terminal box comply with the wiring diagram inside the terminal box cover Earth connection metal parts of the motor that are normally not live must be earthed by means of the relative terminal in the terminal box use a cable with an adequate section Feo co seipee Schema di collegamento trifase singola polarita Three phase single polarity wiring diagram A Y Voltaggio minimo Voltaggio massimo Minimum voltage Maximum voltage wA 2 v2 U V Ww U C Ww V1 U2 JM GM JMM Schema di collegamento monofase Single phase wiring diagram Rotazione anti oraria Amti clockwise rotation Rotazione oraria Clockwise rotation Hig 2 1 Draw 2 1 3 2 Collegamento accessori Collegamento protezione termiche Terminali posti all interno della scatola morsettiera motore Le protezioni necessitano di un apposito rel o apparecchiatura di sgancio a carico dell acquirente del motore Prima del collegamento verificare le caratteri stiche riportate nella targhetta adesiva che identifica il tipo di protezione ATTENZIONE il mancato collegamento delle sonde termiche quando presenti comporta l annullamento della garanzia del motore Collegamento sensore di temperatura PT 100 termometro a resi stenza Conformi alle norme DIN IEC 751 Prima del collegamento verificare le caratteristiche riportate sella targh
30. orretto serraggio dei morsetti elettrici posizionare correttamente la guarnizione e richiudere la scatola morsettiera Per installazioni in ambienti con frequenti spruzzi d acqua si consiglia di sigillare la scatola morsettiera e l entrata cavi con mastice per guarnizioni 3 3 Coppie di serraggio Tab 3 1 Tab 3 1 s seipee gf Important once the connections have been made check to make sure that the electric terminals are well tightened position the seal correctly and close the terminal box again If the motor is installed in a place where it is frequently subjected to splashing water it is advisable to seal the terminal box and cable inlet with sealing cement 3 3 Tightening torques Filetto Thread M4 M5 M6 M8 M10 M12 M16 M20 M24 1 Nm 1 5 1 8 3 3 5 5 6 8 10 14 18 22 25 35 40 50 60 75 90 2 Nm 2 6 3 5 5 7 10 12 22 26 44 50 80 90 180 210 1 Coppia di serraggio dadi esagonali morsettiera motore collegamento elettrico 2 Coppia di serraggio bulloni fissaggio componenti motore scudi flange piedi scatola morsettiera copri ventola morsetto di terra 4 MANUTENZIONE 4 1 Manutenzione periodica Da effettuarsi in condizioni di totale sicurezza motore fermo scollegato dalla rete di alimentazione Verificare che l intero circuito di raffreddamento carcassa entra ta d aria dal lato ventola eventuale servoventilatore sia esente da polve re oli e da qualsiasi residuo di lavorazione in mod
31. pioggia e da spruzzi d acqua sigillare la scatola morsettiera e l entrata cavo con mastice da guarnizione Fondazione deve essere ben dimensionata per garantire stabilit al fis saggio Accoppiamenti per il foro degli organi calettati sull estremita dell al bero consigliata la tolleranza H7 prima di eseguire l accoppiamento pulire e lubrificare le superfici di contatto per evitare pericoli di grippaggio Nelle operazioni di montaggio smontaggio utilizzare sempre appositi tiranti estrattori per evitare eventuali danni ai cuscinetti del motore L uso del martello quindi da escludere E consigliabile riscaldare eventuali giunti pulegge fino a 60 80 C prima del montaggio Accoppiamento diretto curare l allineamento del motore rispetto a quello della macchina condotta Accoppiamento a cinghia verificare che l asse del motore sia sempre parallelo all asse della macchina condotta lo sbalzo della puleggia deve essere il minimo possibile la tensione delle cinghie non deve essere ecces siva per non compromettere la durata dei cuscinetti o provocare la rottura dell albero motore motori sono equilibrati con mezza linguetta per evitare vibrazioni e squilibri necessario che gli organi di trasmissione siano stati opportunamente equilibrati prima dell accoppiamento Per servizi con eleva to numero di avviamenti necessario proteggere il motore per evitare un surriscaldamento eccessivo utilizzando una protezione termica l
32. s with an adequate sleeve resting on the inner ring when assembling the bearings or preheat the bearing to a temperature of about 80 and place it in its housing Make sure that the inner rings rest correctly against the shaft supports and that the replaced bearings are the same as the original ones or an equivalent type It is always advisable to replace the seals on the shaft P 7 SS sepee 4 2 Lubrificazione cuscinetti Procedimenti per la rilubrificazione dei cuscinetti non schermati Se l intervallo di rilubrificazione inferiore ai sei mesi periodo indicativo tutto il grasso esistente va comunque sostituito completamente al massi mo dopo 2 3 rabbocchi Se l intervallo di rilubrificazione superiore ai sei mesi periodo indicati vo tutto il grasso va sostituito ogni sei mesi Per sostituire completamente il grasso usato se i supporti sono accessibili consigliabile rimuovere il grasso esistente e rilubrificare il cuscinetto manualmente Lo spazio libero all interno del cuscinetto va riem pito tutto con grasso fresco mentre lo spazio nel supporto va riempito per Il 30 50 La quantit di grasso nello spazio attorno al cuscinetto non deve essere eccessiva per non causare un innalzamento locale della tem peratura che sarebbe dannoso sia per il grasso sia per il cuscinetto atten zione a non introdurre impurit nel cuscinetto o nel supporto Se i supporti non sono accessibili possibile sostituire completame
33. site control Terminals installed inside a switch box enbloc with the motor housing Connection of the anti condensation heater Terminals installed inside the motor s terminal box Check the specifications on the sticker that identifies the type of protection prior to connection check the power supply specifications The heater must not be powered while the motor is running Connection of the forced axial fan The powering terminals are installed in an auxiliary terminal box on the fan cover Check the specifications on the identification sticker prior to connection check the power supply specifications ft Important make sure that the direction in which the three phase fan spins corresponds to the direction indicated by the arrow on the fan cover Switch two of the three power phases if this is not the case Encoder connection Connection lead equipped with a military tyoe male connector fixed to the motor The female connector and the relative wiring diagram are also supplied Check the specifications on the identification sticker prior to connection i Recommendations for installation use shielded cables with earth connection they must be routed separately from the power cables install the control board as near as possible to the encoder and as far as possible from the inverter when the inverter cannot be shielded in an adequate way rev 00 JM GM JMM fr Importante al termine dei collegamenti verificare il c
34. sponsabilit di adottare opportune misure tecniche ed organizzative e di valutare ogni possibile rischio d esplosione per la salute e sicurezza dei lavoratori in aree potenzialmente esplosive Direttiva 99 92 CE AI ricevimento del motore elettrico accertarsi che non presenti danni o anomalie Prima di mettere in funzione il motore controllare i dati riportati in targa leggere attentamente il manuale di istruzioni in dota zione al motore e verificare la sua idoneit alla applicazione richiesta Nel caso di applicazioni con inverter interpellarci 2 CARATTERISTICHE 2 1 Caratteristiche generali Serie JM G M JMM JM IEC 56 160 0 09 18 5 kW 2 4 6 8 poli trifase GM IEC 160 450 4 900 kW 2 4 6 8 poli trifase JMM IEC 56 100 0 09 2 2 kW 2 4 poli monofase Motore elettrico asincrono trifase normalizzato per uso generale in applicazioni industriali con rotore a gabbia in corto circuito chiuso autoventilato esternamente metodo di raffreddamento IC 411 classe termica d isolamento F sovratemperatura motore classe B per tutti i motori con potenza normalizzata classe B o B F per i rimanenti motori trifasi e monofasi Progettato per operare in servizio continuo S1 a tensione e frequenza nominali I motori JM e GM sono adatti al funzionamento con inverter Non consentito l impiego in luoghi con atmosfere aggressive e con pericolo di esplosione 2 2 Identificazione motore Tab 2 1 Tab 2 1 SS seipee
35. the motor must be protected against excessive heating by means of a thermal protection a magneto thermal circuit breaker is not enough The low voltage starting method can be used to obtain smooth starts at low breakaway starting current values use Y A or soft starters for no load starts or with reduced loads and use an inverter for full load starts or applications with high moments of inertia Operation with inverters JM and GM motors are suitable for operation with inverters limit values power supply voltage U lt 500 V voltage peaks U lt 1 000 V voltage gradients dU dt lt 1 kV us Contact us for gt 500 V power supply voltage values Use of inverters requires the following precautions the entity of these peaks gradients is bound to the inverter s power supply voltage and the length of the motor s feeder cables To limit this entity it is advisable to use special filters at the purchaser s charge installed between the inverter and motor obligatory for gt 30 m feeder cables rev 00 JM GM JMM di tali picchi gradienti legata al valore della tensione di alimentazione dell inverter e alla lunghezza dei cavi di alimentazione del motore Per limita re tale entit si consiglia l utilizzo di appositi filtri a cura dell acquirente posti tra inverter e motore obbligatori per cavi di alimentazione gt di 30 m Ex Motori ATEX 94 9 CE gruppo II categoria 3D per zona 22 l acqui rente del prodotto avr la re

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書    HP BC1500 User's Manual  CELLROUTE 3G - Manual de Instalación Rápida      ANGA H.264 Standalone DVR  AX80 取扱説明書 No.4 落射蛍光観察編  User's manual  TPH Spectra - Class II Total Practice Solution  

Copyright © All rights reserved.
Failed to retrieve file