Home
X61A1633_ D24_Barriera ITA-ENG
Contents
1. FLASHER OUTPUT N i The 230V power line must be protected in direction of the automation by a magnetometric switch or by a couple of 1A fuses It is recommended to use a differential switch but it is not necessary if already present prior to the automation Feed the device with a 3x1 5mm cable phase neutral ground If the distance between the control board and the ground wiring exceeds 30 m it is necessary to install an earth plate near the control board Make sure that the power 230V is switched off before carring out cabling Outputs of contacts N C type if not used must be bridged with an ordinary terminal 24VDC If for the same input there are more N C contacts for the same input it is necessary to connect them in series Outputs of contacts N C type if not used must be left free If for the same input there are more N O contacts it is necessary to connect them in parallel Operating procedures at the first start up e When the power of the control board is switched off undertake wiring and check Unblock the barrier and check the movement The barrier stroke must to be free during the movement Regulate the tension of the spring until the unblocked barrier boom reaches a 45 opening Block the barrier at half of the stroke and turn the power on to the control board The led of power presence lights then on and on the control board display the wording r 00 appears r indicate th
2. O pressione di due secondi In stand by il display mostra la scritta r 00 dove r indica radiocomandi rolling code e le due cifre seguenti indicano quanti radiocomandi sono presenti in memoria La lettera f indica radiocomandi codice fisso Esempio f 03 in questo caso la scritta indica la presenza in memoria di 3 radiocomandi a codice fisso Quando il display mostra questa scritta attraverso i tasti freccia su e gi possiamo commutare la sua visualizzazione in modalit controllo amperometrico In questa modalit il display mostra tre cifre indicanti la corrente assorbita durante il movimento della barriera e due lettere indicanti lo stato della barriera op aperto cl chiuso ba in battuta di apertura bc in battuta di chiusura Esempio 00ch indica barriera chiusa e assorbimento di corrente nullo Questi parametri sono utili per tarare i parametri di sicurezza amperometrica e di spazio di battuta Con display in stand by possibile accedere al menu principale premendo il testo E Navigando con i tasti freccia possibile scorrere le varie voci di configurazione In successione troviamo aggiunta radiocomandi gt regolazioni gt funzioni gt cancella lingua apprendimento gt leggi codici Aggiunta radiocomandi Prima di memorizzare un trasmettitore assicurarsi che sia compatibile con la tipologia di ricevitore integrato con display a riposo apparir r se si tratta di un ricevitore in Modalit
3. OE Se La linea di alimentazione 230V verso l automatismo deve essere protetta da un interruttore magnetotermico oppure da una coppia di fusibili da 1A Un interruttore differenziale consigliato ma non indispensabile se gi presente a monte dell impianto Alimentare I automatismo attraverso un cavo da 3x1 5mm fase neutro terra Se la distanza fra la centrale e la connessione all impianto di terra supera i 30m necessario prevedere un dispersore di terra in prossimit della centrale I cablaggi devono essere effettuati ad alimentazione 230V scollegata Gli ingressi dei contatti di tipo N C normalmente chiuso se non utilizzati vanno ponticellati con un morsetto comune 24VDC Se per lo stesso ingresso ci sono pi contatti N C questi vanno posti in serie tra di loro Gli ingressi dei contatti di tipo N O normalmente aperto se non usati vanno lasciati liberi Se per lo stesso ingresso ci sono pi contatti N O questi vanno posti in parallelo tra di loro Procedura operativa al primo avvio e Effettuare i cablaggi elettrici richiesti dall impianto e controllarli a scheda spenta Sbloccare la barriera e controllarne il movimento La corsa della barriera non deve presentare punti duri durante il Movimento che deve essere fluido Tensionare la molla di contrasto fino a quando l asta della barriera sploccata non raggiunge l apertura di 45 Bloccare la barriera a met della sua corsa e alimentare la
4. bc closing strike For example 00ch indicates that the barrier is closed and that there is no absorbed current These parameters are useful to regulate amperometric security parameters and the strike space When the display is in stand by it is possible to access the main menu pressing the E ENTER button ll is possible using the arrows to scroll configuration sections In succession you find add transmitters gt adjustments gt functions lt gt delete gt language gt set up gt read codes 23 Add transmitters Before memorizing a transmitter make sure that it is compatible with the type of receiver that is integrated with the display in stand by r will appear for a rolling code receiver or f for a fixed code receiver The receiver can memorize rolling codes type HCS300 STAGNOLI with billions of Combinations or fixed codes type HT53200 with 13 bits or the fixed part of a rolling code 28 bits SN It is possible to memorize up to 76 codes different transmitters e Enter the menu add transmitter pressing the E ENTER button move over the wording display Ich or 2ch or 3ch with the arrows and select the channel to be memorized Press E ENTER button to confirm the channel to be memorized Then press the button of the transmitter to be memorized when the press wording appears on the display The wording ok will appear on the display if the operation has been carried out correctly or err if there are registr
5. centrale A questo punto si accender il led di presenza rete e sul display della centrale comparir la scritta r 00 r indica che il ricevitore integrato in modalit rolling code e 00 indica che non ci sono trasmettitori memorizzati Entrare nel men premendo il tasto E Enter Con la freccia gi scorrere nel menu fino alla voce lingua Premere nuovamente il tasto E Enter Selezionare la lingua desiderata scorrendo il sottomenu con i tasti freccia Premere il tasto E Enter per confermare la lingua desiderata successivamente tenere premuto il tasto E ESC per uscire dal men lingua Attivare uno alla volta i dispositivi di sicurezza e verificare che a display compaia la scritta di diagnostica relativa Ad esempio far intervenire la fotocellula e verificare che compaia a display il messaggio pho se si tratta di fotocellula attiva solo in chiusura o phoA se si tratta di fotocellula attiva sia in chiusura che in apertura Con la freccia gi scorrere il menu fino alla voce apprendimento e premere nuovamente il tasto E Enter A questo punto la barriera andr in apertura se dovesse andare in chiusura invertire i cavi del motore se non dovesse muoversi ne in apertura ne in chiusura verificare che le sicurezze e I encoder siano correttamente collegati poi andr in chiusura e ripeter l operazione una volta Le prime due manovre servono 5 N iS per identificare l inizio e la fine della corsa del motore le due seguent
6. has opened fully Set ttca to adjust the time that must elapse between the end of the opening and the beginning of the automatic closing e ba impulse block during opening the control board ignores the START impulses during the opening phase e bp block impulses during pause the control board ignores START CLOSE OPEN impulses during the pause between the opening and the automatic closing These functions are useful in case of many passages with many inputs in the same entry 25 N ai cr rapid closing activates the automatic rapid closing time after the passage through photocells during the opening phase or when the barrier is open The ttca regulating time if active and higher than ch r is automatically reduced to chr seconds 2p open close operation if active at each START impulse the movement of the barrier inverts the direction OPENING CLOSING If not active the barrier sequence of the barrier is OPENING PAUSE ttca CLOSING STOP pl preflashing after the opening barrier command the flasher or the courtesy light actives for two seconds before the opening or closing phase begins sv suction lock if active the electric lock output becomes suction lock i e always active 24VDC when the barrier is closed re Energy saving keeps the photocells off while the system is not active permitting Energy saving Photocells therefore remain active only during the barrier movement Connect 2
7. mechanical strokes Before proceeding with this operation ensure that the barrier has been installed correctly and firmly and that the en function of the control board has been activated Stagnoli supplies the control board with this function already activated en 1 Place the barrier at half stroke Press E ENTER button to enter the menu then with the arrows go to learning menu and press the E ENTER button At this point the barrier will open in case of closing invert motor cables if the barrier doesn t close or open check security devices and encoder connections then it will close and will repeat this operation 27 O pai once more The two first manoeuvres are to identify the beginning and the end of the motor stroke The two following manoeuvres are to detect the motor absorption peak during the opening and closing of the barrier In this phase check the displayed values These values important for the amperometric security are indicated by the a letter and two numbers on the display during the opening and by the b letter and two number during the closing At the end of the Learning procedure the wording ok will appear on the display if the operation has been carried out correctly or err if there are registration errors Press the E ENTER to exit from programming Insert correctly in the menu anti crushing force levels in opening and closing that must be upper than maximum values displayed during the learning WARNING th
8. ms master SI slave Setup stroke setup Read code identification and recognition of transmitters Configuration of the control board To set up the control board it is possible to have access to each parameter from the tree menu on the display To access the menus or to undertake an operation press the ENTER E button and release immediately Keeping the same button pressed it will be possible to return to the upper menu or to cancel the operation requested ESC function To navigate in the menus use the up and down arrows WARNING During the navigation in the menus the control board ignores START CLOSE and OPEN commands Arrow up Arrow down O 1 nn ENTER function EE s O I single pression Ah ESC function N E pression for two seconds In stand by the display shows the r 00 wording where r indicates rolling code transmitters and the two numbers indicate the number of transmitters registered in the memory The f letter indicates fixed codes transmitters For example f 03 in this case the wording indicates that 3 fixed code transmitters are registered in the memory When this wording is shown on the display with the arrows up and down change the visualization in amperometric check mode In this mode the display shows two numbers indicating the absorbed current during the barrier movement and three letters indicating the barrier state op open cl close ba opening strike
9. nel men Portarsi sulla lingua desiderata tramite i tasti freccia e confermare premendo nuovamente E ENTER Per uscire dal men lingua premere per due secondi il tasto E ESC 13 Apprendimento Questa operazione permette all automazione di stabilire automaticamente l inizio e la fine della corsa Prima di procedere con questa operazione assicurarsi che la barriera sia solidamente installata e che la funzione en della centrale sia attiva Stagnoli fornisce la centrale con questa funzione gi attivata en 1 Posizionare la barriera a met corsa Premere il tasto E ENTER per entrare nel men e spostarsi con i tasti freccia fino ad arrivare al sottomenu apprendimento e premere il tasto E ENTER A questo punto la barriera andr in apertura se dovesse andare in chiusura invertire i cavi del motore se non dovesse muoversi ne in apertura ne in chiusura verificare che le sicurezze e I encoder siano correttamente collegate poi andr in chiusura e ripeter l operazione un altra volta Le prime due manovre servono per identificare l inizio e la fine della corsa del motore Le due seguenti servono a rilevare il picco di assorbimento del motore durante l apertura e la chiusura della barriera In questa fase monitorare i valori visualizzati a display Questi valori importanti per la sicurezza amperometrica sono indicati dalle due cifre del display precedute dalla lettera a durante la fase di apertura dalla lettera c durante la fase di chi
10. sottomenu e premere il tasto E ENTER Verr visualizzato il messaggio rese che lampegger fino a quando non sar confermata l intenzione di reimpostare tutti i parametri tramite tasto E ENTER o di annullare l operazione tramite tasto E ESC e cancella 1 radiocomando per cancellare il codice di un trasmettitore portarsi sulla dicitura 1 radiocomando del sottomenu e premere il tasto E ENTER Verr visualizzato il messaggio premi Premere a questo punto il tasto del trasmettitore da cancellare Se l operazione sar portata a termine in maniera corretta verr visualizzato il messaggio ok In caso contrario err e cancella tutta memoria radio per cancellare tutti i trasmettitori registrati portarsi sulla dicitura tutta memoria radio del sottomenu e premere il tasto E ENTER Verr visualizzato il messaggio prg che lampegger fino a quando non sar confermata l intenzione di cancellare tutti i codici registrati premendo il tasto E ENTER o di annullare l operazione premendo il tasto E ESC N B Per portare a termine la cancellazione della memoria radio viene richiesto di confermare due volte la volont di effettuare la cancellazione stessa cancella tutta memoria radio e prg Lingua Il display pu visualizzare i messaggi in pi lingue italiano francese inglese e spagnolo Per scegliere la lingua di funzionamento premere il tasto E ENTER e portarsi sul sottomenu lingua attraverso i tasti freccia e premere E ENTER per entrare
11. the menus or to undertake an opera tion press ENTER E and release immediately Keeping the same button pressed it will be pos sible to return to the upper menu or cance the operation requested ESC To navigate in the menus use the up and down arrows JOLT ENTER press and Ol release JO rc press for two seconds 21 gt lt gt delete Reset parameter Italiano Erase 1 transmitter Frangais Erase all transmitters English Espagnol Adjustments e tica automatic closing time e rlap pedestrian opening e rich slowed stocke in closing e rppm motor speed e rpmc slow speed during the closing e fmla anti crushing force of the motor in opening e fmic anti crushing force of the motor in closing e sbat strike space e chr rapid closing e rel auxiliary relay time Delete e Parameter Reset restore factory parameters e Erase 1 transmitter deletion of one transmitter e Erase memory transmitters deletion of all memory transmitters 22 language Functions e ca automatic closing e ba blocks impulses during opening e bp blocks impulses during pause e cr rapid closing e 2p open close operation e PI preflasing e sv suction lock e re Energy saving e en encoder operation e ss soft start e oc open close operation e cf operation of the fixed code integrated receiver 3c third transmitter channel sc open barrier warning light
12. the transmitter N B During the displaying of the wording press when the transmitter key is pressed if nothing changed on the display it means that the transmitter is not compatible with the Stagnoli control board make sure that the receiver is correctly inserted and that antenna is correctly mounted 28 Synchronization With two Daphne control boards it is possible to configure two synchronized barriers to allow to double the opening length In this mode the two control boards communicate by cable 4 poles to synchronize movements One control board master will control the opening while the other control board slave will execute commands sent by the master control board Connect only to the master control board photocells and input controls Encoder and amperometric security devices will however be active in the slave control board Connect the cable between the two control boards that allows the synchronization to the terminal M2 see figure 1 component 17 connecting the TX output of the master T1 T2 to the RX input of the slave R1 R2 et vice versa Activate master and slave correspondent parameters as described in the functions menu paragraph Statistics screens The control board has three statistics screens that are viewed by keeping the key ENTER pressed once the display is in stand by e first screen d vl where d indicates the motor Daphne at 24V and 01 the software version e second and third screens 0000
13. 0000 indicate the number of complete manoeuvres undertaken by the control board Diagnostic screens The control board can recognize problems or alarms that occur in the system and can show them on the main display in stand by and not in amperometric checking o rf activation of the OPEN command on the first radio frequency channel c rf activation of the CLOSE command on the second radio frequency channel iirf activation of the 3ch command on the third radio frequency channel sta activation of the START command on the terminal input stop activation of the STOP command on the terminal input open activation of the OPEN command on the terminal input clos activation of the CLOSE command on the terminal input pho activation of the photocells input in closing on the terminal phoa activation of the photocells input in opening and in closing on the terminal am 1 operation of amperometric sensor enc 1 operation of the sensor with encoder encs operation of the sensor with encoder on the slave in synchronized mode amps operation of the amperometric sensor on the slave in synchronized mode e ac communication of disturbed synchronization in synchronized mode nac No communication between master and slave in synchronized mode 29
14. 4V power of the photocell transmitter and receiver to the flasher output en encoder operation manages the motor to operate with encoder In case of encoder malfunction the barrier locks after the start and on the display the wording encll appears it is possible to inactivate this function and to allow the motor to carry out other dead man manoeuvres i e keeping pressed the START CLOSE or OPEN button WARNING the operation of the system without encoder is to be considered as being an emergency operation In this mode every obstacle encountered by the motor will make stop the movement without its inversion ss soft start allows the motor to undertake a soft start at a reduced speed to diminish stress of the mechanical parts of the system Activating this function the motor delivers less power in the starting phase oc open close function the START terminal input becomes OPEN Activating this function a command open the barrier and another command closes the barrier cf operation of the fixed code integrated receiver if active the receiver works with fixed codes 3c third transmitter channel if active when the third channel is pressed the auxiliary relay contact closes during the time in seconds set up in the rel parameter Check to have registered in the memory the third transmitter channel sc open barrier light if active the electric suction lock output becomes the open barrier light As long as the ba
15. amite i tasti freccia e premere E ENTER per visualizzare il valore impostato Utilizzare i tasti freccia per modificare il parametro e confermare tramite il tasto E ENTER Per uscire dai men tenete premuto il tasto E ESC per circa 2 secondi e ttca tempo di chiusura automatica il tempo che intercorre tra l apertura completa della barriera e la sua chiusura che avviene in modo automatico Se la fotocellula occupata il tempo di ttca viene conteggiato dal momento in cui la fotocellula si disimpegna Il tempo impostato di default 10sec ed regolabile da 1 a 240sec e rlap corsa rallentata in apertura la centrale rallenta la corsa del motore nella parte finale della sua fase di apertura Il rallentamento impostato di default il 50 della corsa ed regolabile da 0 a 90 Impostare questo valore affinch la barriera non presenti forti oscillazioni nell arrivare a fine corsa in apertura e rich corsa rallentata in chiusura la centrale rallenta la corsa del motore nella parte finale della sua fase di chiusura Il rallentamento impostato di default il 50 della corsa ed regolabile da 0 a 90 Impostare questo valore affinch la barriera non presenti forti oscillazioni nell arrivare a fine corsa in chiusura e rpm velocit motore impostare la velocit del motore durante la sua fase di apertura chiusura La velocit impostata di default 5 ed regolabile da 1 a 10 10 AD e e rpmc velocit di rallentame
16. at the integrated receiver is in rolling code mode and 00 indicate that no transmitter is memorized Enter in the menu pressing the E Enter button Scroll down with the down arrow the menu to the language Press again the E Enter button Select the language scrolling down with arrow buttons Press the E Enter button to confirm the chosen language and keep the E ESC button pressed to exit Set going one at a time security devices and check that on the display the wording for the correspondent diagnostic appears For example set going the photocell and check that on the display the pho message appears if it s a photocell functioning only in closing or the phoA message if it is a photocell functioning in opening and in closing e With the arrow down scroll the menu to set up an press again the E Enter button The barrier opens in case it closes invert the cables of the motor if it doesn t open or close check that the security devices or the encoder is correctly connected then it closes and the operation will be repeated The first two operations are to read the absorption peak to identify the beginning and the end of the motor stroke during the barrier opening and closing In this phase it s necessary to check the values on the display These values important for the amperometric security are indicated by the two 19 O ili numbers on the display with the letter a before during the opening phase and with the letter c duri
17. ation errors or full if the receiver memory is full If nothing happens it means that the transmitter is not compatible e An external antenna installed far from the ground increases the visibility between the transmitter and the receiver The power of the receiver can be reduced if metal parts or reinforced concrete are placed next to it Adjusments Enter the Adjustment menu to regulate parameters Choose the parameter to be regulated using the arrows and press the E ENTER button to see the registered value Use the arrows to modify the parameter and confirm by pressing the E ENTER button Press the E ESC button for about 2 seconds to exit from menus e tica automatic closing time this is the time from when the barrier is fully open to when it is closed automatically If the photocell is engaged the ttca time is counted from the time when the photocell is free The default time set by Stagnoli is 10 sec and it can be regulated from 1 to 240 sec e rlap slowed stroke in opening the control board slows down the stroke of the motor in the end part of its opening The set up default stroke set is 50 and it can be regulated from 0 to 90 Regulate this value to prevent the barrier from having oscillations when it arrives at the end of the stroke in opening e rich slowed stroke in closing the control board slows down the stroke of the motor in the end part of its closing The set up default stroke set is 50 and it can be regulated f
18. avr comunque attivi i sistemi di sicurezza encoder e amperometrica Il cavo di collegamento fra le due centrali che permette la sincronizzazione deve essere collegato al morsetto M2 vedi figura 1 componente 17 collegando l uscita TX del master T1 T2 con l ingresso RX dello slave R1 R2 e viceversa Attivare i corrispettivi parametri di master e di slave come descritto nel paragrafo men funzioni Schermate di statistica La centrale di comando dispone di tre schermate statistiche che vengono visualizzate mantenendo la pressione del tasto ENTER mentre il display si trova a riposo e prima schermata d vl dove d indica il motore Daphne a 24V e 01 la versione del software e seconda e terza schermata 0000 0000 indicano il numero delle manovre complete effettuate dalla centrale fino a quel momento Schermate di diagnostica La centrale in grado di riconoscere i problemi o gli allarmi che si stanno verificando sull impianto e di segnalarli sul display principale mentre a riposo e non in controllo amperometrico o rf attivazione del comando OPEN sul primo canale di radiofrequenza c rf attivazione del comando CLOSE sul secondo canale di radiofrequenza iirf attivazione del comando 3ch sul terzo canale di radiofrequenza sta attivazione del comando di START sull ingresso della morsettiera stop attivazione del comando di STOP sull ingresso della morsettiera open attivazione del comando di OPEN sull ingresso della morsett
19. del radiocomando dove S indica Stagnoli mentre un produttore generico Il secondo carattere indica la tipologia di codice dove r indica rolling code mentre f indica codice fisso Gli ultimi due caratteri indicano il canale del tasto premuto e seconda schermata P_00 dove P indica la parola posizione mentre la cifra successiva progressiva da 0 a 75 indica la posizione occupata dal trasmettitore in memoria Se il trasmettitore non dovesse essere presente in memoria apparir sul display 14 uu _OO_________o o _o oo oooo ooo sii terza e quarta schermata verr visualizzata la codifica esadecimale del trasmettitore N B Durante la comparsa della scritta premi se alla pressione del tasto del radiocomando non cambia nulla significa che il radiocomando utilizzato non compatibile con la centrale Stagnoli assicurarsi prima che il modulo ricevente sia inserito bene nello zoccolo e che sia montata correttamente l antenna Sincronizzazione Tramite due centrali Daphne possibile configurare due barrire in modo sincronizzato permettendo di raddoppiare la larghezza dell apertura In questa Modalit le due centrali comunicano via cavo a 4 poli per sincronizzare i movimenti Una centrale master sar al comando dell apertura mentre l altra centrale slave eseguir i comandi inviati dalla centrale di comando Le fotocellule ed i comandi di ingresso vanno collegati unicamente alla centrale master La centrale slave
20. ell apertura e l inizio della chiusura automatica 11 ba blocco impulsi durante l apertura la centrale ignora gli impulsi di START durante la fase di apertura bp blocco impulsi durante la pausa la centrale ignora gli impulsi di START CLOSE OPEN durante la pausa tra l apertura e la chiusura automatica Queste funzioni si rivelano utili nei casi in cui vi siano diversi passaggi con diversi input attraverso lo stesso ingresso cr chiusura rapida attiva il tempo di chiusura rapida automatica dopo il passaggio attraverso le fotocellule durante la fase di apertura o a barriera aperta Il tempo della regolazione ttca se attivato e superiore di ch r viene automaticamente ridotto al tempo ch r impostato 2p funzionamento apri chiudi se attivo ad ogni impulso di START il movimento della barriera inverte la direzione APERTURA CHIUSURA Se disattivo la sequenza di movimento della barriera diventa APERTURA FERMATA tica CHIUSURA STOP pl prelampeggio dopo il comando di apertura della barriera il lampeggiante o la luce di cortesia si attivano per due secondi prima che venga iniziata la fase di apertura o di chiusura sv serratura elettromagnetica se attiva l uscita elettroserratura diventa sempre attiva 24VDC a barriera chiusa re risparmio energetico mantiene le fotocellule spente mentre l impianto non attivo consentendo risparmi energetici Le fotocellule cos rimangono attive solo durante il movimen
21. evated current absorption At the end of the installation check that the force of impact is in compliance with the regulation EN12453 e sbat striking space this is the percentage of the stroke individuated as strike space In the area the amperometric or encoder security will be detected as limit switch and not as obstacle The default value set by Stagnoli is 10 and can be regulated from 5 to 20 e chr rapid closing time this is the automatic closing time when there is a passage through the photocells during the opening phase or when the barrier is open The regulationg time ttca if activate and upper than the ch r time is automatically reduced to the set up chr time The default value set up by Stagnoli is 3 and can be set up from 1 to 10 sec e rel auxiliary relay time this is the time during which the auxiliary relay contact remains closed after the barrier has closed In case of active parameter 3c this value indicates in how many seconds the auxiliary relay contact will be closed after having pressed the transmitter third channel Functions Enter in the functions menu to regulate parameters With the arrows choose the parameter to be modified and press the E ENTER button to see if the function is active 1 or not 0 Press the arrow buttons to modify Then confirm pressing the E ENTER button and press the E ESC button for about 2 seconds to exit e ca automatic closing automatic closing of the barrier after it
22. gi adatti all automazione Daphne pericolosit residua sulla necessit della manutenzione e sulla necessit di un Informare accuratamente l utilizzatore finale sulla Modalit d uso sulla 4 controllo dei dispositivi di sicurezza almeno ogni sei mesi RESI L E Freccia giu ia Enter Esc Per accedere ai menu o per eseguire un opera zione premere il tasto ENTER E gioni ve locemente Prolungando la pressione sullo stesso tasto sar possibile tornare al men superiore o annullare l operazione richiesta funzione ESC Per navigare nei men usare i tasti freccia su e freccia gi Memoria impianto Display Tasti di impostazione 3a freccia su 3b freccia gi e 3c Enter Esc Rel direzione motore Rel direzione motore MOSFET motore Rel ausiliario di cortesia Rel lampeggiante Modulo ricevitore Fusibile T 3 15A Fusibile T 10A Uscite accessori Ingresso 24 AC DC PTC 0 1 A Morsetto antenna TX RX sincronizzazione per seconda barriera Morsetto di terra Input comandi Input Encoder Uscita motore Rel ausiliario PTC 0 9 A MOSFET serratura Ho are UD UUUUU Itttfti aver Ho COMUNE 24Vdc APRI N O STOP N C FOTOCELLULA CHIUSURA N C FOTO APERTURA CHIUSURA N C l CHIUDI START N O COMUNE 24Vdc Q MUU UU Pratt Input Comandi 19 Uscite Accessori 13 ELETTROSERRATURA ELETTROMAGNETICA 24Vac PER ACCESSORI USCITA LAMPEGGIANTE
23. i servono a rilevare il picco di assorbimento del motore durante l apertura e la chiusura della barriera In questa fase necessario monitorare i valori visualizzati a display Questi valori importanti per la sicurezza amperometrica sono indicati dalle due cifre del display precedute dalla lettera a durante la fase di apertura dalla lettera c durante la fase di chiusura AI termine della fase di apprendimento sul display sar visualizzato ok nel caso di corretta programmazione o err nel caso vi siano stati degli errori Per uscire dalla programmazione premere per due secondi il tasto di selezione E Esc Impostare correttamente i livelli di forza antischiacciamento in apertura e in chiusura nel menu che devono essere superiori ai valori massimi visualizzati durante l apprendimento Questa regolazione pu influire sul grado di sicurezza dell automazione Durante le manovre di apprendimento la centrale ignora i comandi di START OPEN CLOSE e lavora con i parametri di forza al massimo Anche se rimangono attive le sicurezze assicurarsi che non vi siano oggetti o persone sulla traiettoria di lavoro della barriera Effettuare alcuni cicli di prova verificando il corretto funzionamento di tutto l impianto Effettuare le misure della forza di impatto della barriera secondo quanto specificato dalle norme EN12445 MENU AD ALBERO Indicazioni al primo avvio e r indicatore ricevitore rolling code e 00 trasmettitori memorizzati Agg rad
24. iera clos attivazione del comando di CLOSE sull ingresso della morsettiera pho attivazione del l ingresso delle fotocellule in chiusura sulla morsettiera phoa attivazione dell ingresso delle fotocellule in apertura e in chiusura sulla morsettiera am 1 intervento del sensore amperometrico encl intervento del sensore ad encoder encs intervento del sensore ad encoder sullo slave in modalit sincronizzata amps intervento del sensore amperometrico sullo slave in modalit sincronizzata e ac comunicazione di sincronizzazione disturbata in modalit sincronizzata n ac comunicazione tra master e slave assente in modalit sincronizzata 15 Stagnoli D24 is the control board designed for the 24V Daphne Barriers Manufactured only with first choice products it has been designed to have low power consumption when not in use A particular attention has been paid to professional people of this sector making easier the control board programmation thanks to a multilingual display 4 languages WARNINGS AND SECURITY NORMS This manual has been written by Stagnoli for a specific use of professional and qualified people It is recommended to read the entire instruction manual before installing the product During the wiring electrical power must be turned off Automatic gate installations must be done by qualified technical staff and law norms must be respected DOUBLE SECURITY The control board has two security sens
25. iocomandi thy thy Ich regolazioni ttca B 2ch rlap 3ch rlch e 1Ch memorizzazione del comando start close rpmc sul primo canale e 2Ch memorizzazione del comando open sul secondo canale nel funzionamento open close OC 1 e 3Ch memorizzazione del comando rel sul terzo canale Per accedere ai men o per eseguire un opera zione premere il tasto ENTER E rilasciandolo ve locemente Prolungando la pressione sullo stesso tasto sar possibile tornare al men superiore o annullare l operazione richiesta funzione ESC Per navigare nei men usare i tasti freccia su e freccia gi LOL funzione ENTER O l pressione semplice O E funzione ESC pressione di due secondi 7 H I funzioni Q o n N a 5 lt zo g lt H O Ji italiano leggi codice francese cancella reset parametri Cancella 1 radiocomando Cancella tutta la memoria l inglese radio lt spagnolo Regolazioni Funzioni z NE e ca chiusura automatica Hei MPo Gr CMS AWIONONC ba blocca impulsi durante l apertura e rlap corsa rallentata in apertura bp blocca impulsi durante la pausa e rich corsa rallentata in chiusura e cr chiusura rapida eles velocita motore s sE e 2p funzionamento apri chiudi e rpmc regolazione velocit e intensit del e PI prelampeggio rallentamento durante la chiusura svela veni e fm
26. is operation can influence on the automation security grade During learning manoeuvres the control board will ignore START OPEN and CLOSE commands and will work with the maximum force parameters Even if the safeties remain active ensure that there are no objects or people in the area of operation of the barrier Carry out some test working cycles checking the correct functioning of the whole installation Measure the impact force of the barrier in respect with EN12445 norms dispositions Read code It is possible to check if a code has already been memorized or to read the code of a new transmitter checking if it is compatible with the control board Position yourself on the wording read code press E ENTER When the display will show the message PRESS press the transmitter key that must be checked e first screen SrO or SfOlor 101 or f01 etc The first letter indicates the manufacturer of the radio control where S means Stagnoli and a generic manufacturer The second letter indicates the type of code where r indicates a rolling code and f a fixed code The last two indicate the code of the key that was pressed e second screen P_00 where P indicate the word position and the number that follows progressive from 0 to 75 indicates the position occupied by the transmitter in the memory If the transmitter is not found in the memory the display will show third and fourth screens show the hexadecimal code of
27. la forza antischiacciamento del e re risparmio energetico NOSEM apertum i i e en funzionamento encoder e fmic forza antischiacciamento del ass softstart Li a i Hut e oc funzionamento open close erat Acei ea e cf funzionamento del ricevitore integrato e chr chiusura rapida gt i a codice fisso rel tempo rel ausiliario e 3c terzo canale radiocomando e sc spia barriera aperta e ms master e SI slave Cancella Apprendimento apprendimento della corsa e Reset parametri ripristino dei parametri di fabbrica e Cancella 1 radiocomando cancellazione di Leggi codice identificazione e riconoscimento un trasmettitore trasmettitori e Cancella tutta la memoria radio cancellazione di tutti i trasmettitori memorizzati Configurazione della centrale Per la configurazione della centrale di comando ogni parametro accessibile dal menu ad albero visualizzato tramite display Per accedere ai men o per eseguire un operazione premere il tasto E ENTER rilasciandolo velocemente Prolungando la pressione sullo stesso tasto sar possibile tornare al men superiore o annullare l operazione richiesta ESC Per navigare nei menu o nei sottomenu usare i tasti freccia ATTENZIONE Durante la navigazione nei menu la centrale ignora i comandi di START CLOSE e di OPEN Freccia su Freccia gi LOT f VS p Funzione ENTER C pressione semplice a ae GA i ca Tp Funzione ESC
28. morizzato il terzo canale radio 12 N iS e sc spia barriera aperta se attivo l uscita elettroserratura ventosa diventa l uscita spia barriera aperta Finch la barriera rimane aperta questa uscita rimarr attiva a 24VDC e ms master attivare questa funzione se si desidera che la centrale diventi master in una configurazione a due barriere vedere paragrafo sincronizzazione In questo Modo la centrale riceve i comandi di apertura chiusura e fotocellule secondo il cablaggio effettuato e trasmette alla centrale slave i comandi per controllare il movimento sincronizzato ATTENZIONE non attivare entrambe i parametri ms e sl e sl slave attivare questa funzione se si desidera che la centrale diventi slave in una configurazione a due barriere vedere paragrafo sincronizzazione In questo Modo i comandi di apertura chiusura e fotocellule sono ricevuti dalla centrale master che controlla i Movimenti ATTENZIONE non attivare entrambe i parametri ms e sl Cancella In questo sottomenu possibile ripristinare i parametri di fabbrica o cancellare i radiocomandi presenti in memoria Entrando nel sottomenu cancella scegliere la voce desiderata tramite i tasti freccia e confermare con il tasto E ENTER Uscire tenendo premuto il tasto E ESC per circa 2 secondi e reset parametri per reimpostare tutti i valori delle regolazioni e delle funzioni a quelli di fabbrica premere il tasto E ENTER e portarsi sulla dicitura reset parametri del
29. nfirmed with the E ENTER button or the operation is cancelled with the E ESC button e erase 1 transmitter to cancel a transmitter code go to the wording 1 transmitter and press the E ENTER button The message PRESS will appear Press now the key of the transmitter that must be cancelled If the operation has been carried out correctly the message OK will appear If this has not been put correctly the message ERR will appear e Erase all memory transmitters to cancel all the recorded transmitters go to the wording all memory transmitter and press the E ENTER button The message prg will appear it flashes until the decision to cancel all the recorded codes is confirmed by pressing E ENTER or the operation is cancelled by keeping the same key E ESC pressed for longer N B To cancel the memory of the receiver it is necessary to confirm twice the cancellation erase memory transmitters and PRG Language The display is available in four languages italiano frangais english espagnol To chosen the operation language press the E ENTER button and go to the lingua menu with the arrows then press the E ENTER button to enter in the menu Go to the chosen language with the arrows and confirm pressing again the E ENTER button To exit from the language menu press for two seconds the E ESC button Learning This operation allows the automation to automatically establish the start and end of a stroke identifying the respective
30. ng the closing phase When the set up phase is finished ok appears on the display if the programming is correct or err appears in case of error Press for two seconds the E Esc selection button to exit from the programming Insert correctly in the menu the levels of anti crushing force in opening and in closing that must be higher than maximum displayed values during the learning phase This regulation can affect the security grade of the automation During learning manoeuvres START OPEN CLOSE commands are not active and the control board works with the force parameters at the maximum Make sure even if security devices are still active that nobody and nothing is on the working stroke of the barrier Undertake some test cycles checking the good functioning of the whole installation Measure the barrier impact force in respect with what is specified by the EN12445 norm 20 TREE MENU Indications at the first start up e r rolling code receiver indicator e 00 registered transmittors ti Add transmitters adjustments functions gt lt Ich ttca ca 2ch 3ch rlch rpm Cr e 1Ch memorization of start close transmitter on the first channel rpmc e 2Ch memorization of the open command on the fmla l second channel with open close operation OC 1 fmlc e 3Ch memorization of the relay control on sbat the third channel H O gt gt o a D ko a n N a S B am rel To access
31. nto durante la chiusura impostare la velocit del motore durante la fase di rallentamento in chiusura La velocit impostata di default 18 ed e regolabile da 5 a 20 Stagnoli consiglia di impostare questo parametro nelle barriere da 3 o 4 metri da 15 18 e da 6mt da 18 20 e fmla forza antischiacciamento del motore in apertura la forza antischiacciamento della barriera La forza impostata di default 50 e pu essere regolata da 10 a 99 e fmic forza antischiacciamento del motore in chiusura la forza antischiacciamento della barriera La forza impostata di default 50 e pu essere regolata da 10 a 99 ATTENZIONE l impostazione di questi due parametri pu influire sul grado di sicurezza dell impianto stesso Si consiglia di impostare questi parametri con un margine di sicurezza tale che risultino almeno 10 rispetto al massimo della corrente consumata dal motore rispettivamente in fase di apertura e di chiusura La corrente assorbita durante la corsa del motore si pu leggere sul display nella seconda schermata principale controllo amperometrico fmla e fm1c bassi di valore indicano una maggiore sensibilit antischiacciamento Valori troppo bassi potrebbero rilevare come ostacolo un punto duro di movimentazione e quindi di assorbimento di corrente pi elevato Verificare al termine dell installazione che le forze di impatto rispettino la norma EN12453 e sbat spazio di battuta la percentuale della corsa indi
32. ors an encoder sensor and an amperometric sensor Make sure that the barrier is solid well fixed with fixings adapted to the Daphne automation to it and the need for periodical maintenance and the need to check security Z Explain the final user how the automatism works about possible hazards related devices at least every six months 16 AP LORNA sis 1 13a Arrow Up A Ga Arrow Down ia Enter Esc To access the menus or to undertake an opera tion press ENTER E and release immediately Keeping the same button pressed it will be pos sible to return to the upper menu or cancel the operation requested ESC To navigate in the menus use the up and down arrows System memory Display Setting buttons 3a setup button 3b arrow down and 3c Enter Esc Directional relay motor Directional relay motor MOSFET Motor Courtesy auxiliairy relay blinker relay Receiver module T 3 15A fuse T 10A fuse Accessory outputs 24 AC DC Input PTC 0 1 A Antenna terminal TX RX synchronization for second barrier Ground terminal Control Input Encoder Input Motor Output Auxiliary relay PTC 0 9 A MOSFET electro lock Control Input 19 Accessory Output 13 L L_ L L_ C L_ COMMON 24Vdc HS aver CLOSING PHOTOCELL N C CLOSING OPENING PHOTOCELL N C CLOSING START N 0 COMMON 24Vdc aver Ho ELECTRIC LOCK ELECTROMAGNETIC LOCK 24Vac FOR ACCESSORIES
33. ravaitti erreren ZIUA 9 p ing M U WANK JI DY mS aon ae a a 7 ELLLLLL ck ZAJ T 6S gt 2 gt Y anyep a Centrale di comando per barriere Daphne a 24V Control board for Daphne 24V motors STAGNOLI AUTOMATION SOLUTIONS Stagnoli T G srl Via Mantova trav 105A B 39 0309139511 1 39 0309139580 info stagnoli com www stagnoli com Em D24 di Stagnoli la centrale di comando studiata per le barriere Daphne a 24V Realizzata solo con materiali di prima scelta e stata progettata per avere bassi assorbimenti a riposo permettendo un basso consumo di energia elettrica Particolare attenzione stata rivolta ai professionisti del settore facilitando la programmazione della centrale grazie a un display multilingua 4lingue AVVERTENZE E NORME DI SICUREZZA e Il presente manuale stato realizzato da Stagnoli per lo specifico utilizzo da parte di personale professionista e qualificato e Si consiglia di leggere interamente il manuale di istruzioni prima di procedere all installazione del prodotto e Durante la cablatura non deve esserci la presenza di tensione sull impianto e Gli impianti di cancelli automatici devono essere installati da personale tecnico qualificato e nel rispetto delle norme di legge e DOPPIA SICUREZZA La centrale dotata di due sensori di sicurezza uno ad encoder e l altro amperometrico e Verificare che la barriera sia solida ben fissata con fissag
34. rolling code o f se si tratta di un ricevitore in modalit codice fisso Il ricevitore pu memorizzare codici rolling code di tipo HCS300 STAGNOLI con miliardi di combinazioni o codici fissi di tipo HT53200 a 13 bit o la parte fissa di un codice rolling code 28 bit SN E possibile memorizzare fino a 76 codici trasmettitori diversi e Entrare nel sottomenu aggiunta radiocomando premendo il tasto E ENTER scegliere il canale che si vuole memorizzare portandosi sulla scritta a display Ich o 2ch o 3ch tramite i tasti freccia Premere il tasto E ENTER per confermare il canale da memorizzare Successivamente premere il tasto del radiocomando che si desidera memorizzare quando viene visualizzata la scritta premi a questo punto il display visualizzer la scritta ok se l operazione viene portata a termine in maniera corretta err nel caso si verifichino errori di registrazione o full se la memoria del ricevitore piena Se non accadr nulla significa che il telecomando utilizzato non rientra nello standard adottato da Stagnoli e installando un antenna esternamente alla centrale e lontana dal suolo l area di visibilit tra trasmettitori e centrale aumenta Ricordarsi inoltre che parti metalliche e cemento armato se posti tra la centrale e il ricevitore diminuiscono la capacit di ricezione di questo ultimo Regolazioni Le regolazioni dei parametri si effettuano entrando nel sottomenu regolazioni Scegliere il parametro da modificare tr
35. rom 0 to 90 Regulate this value to prevent the barrier from having oscillations when it arrives at the end of the stroke in closing rpm motor speed set the motor speed during the opening closing phase The set up default speed set is 5 and it can be regulated from 1 to 10 rpmc slowing speed during closing set the motor speed during the slowing phase in closing The set up default speed set is 18 and it can be regulated from 5 to 20 It is recommended to set up this parameter for barriers of 3 o 4 meters from 15 to 18 and for barriers of 6 meters from 18 to 20 24 AD iS e mla anti crushing force in opening this is the anti crushing force of the barrier The default value set by Stagnoli is 50 and it can be regulated from 10 to 99 e fmic anti crushing force in closing this is the anti crushing force of the barrier The default value set by Stagnoli is 50 and it can be regulated from 10 to 99 WARNING the way these two parameters are set can influence the level of safety of the system Stagnoli advises setting this parameter with a safety margin that is at least 10 compared with the maximum current consumed by the motor in the opening and closing phases respectively It is shown during the motor stroke on the display in the second main screen amperometric control fmla and fmic with low values indicate greater anti crushing sensibility Too high values could detect an hard point as an obstacle and therefore a more el
36. rrier is open this output remains active at a 24VDC ms master activate this function in case of configuration of two barriers in order the control board becomes the master see synchronization paragraph In this way the control board receives opening and closing controls and photocells second the wiring and transmits to the slave control board the controls to check the synchronized movement Activate this function if you want the control board becomes master in a configuration of two barriers se paragraph synchronization WARNING don t activate both parameters 26 O iS e sl slave activate this function if you want that the control board becomes slave in a configuration of two barriers see paragraph synchronization In this manner opening closing controls and photocells are received by the master control board that controls movements WARNING don t activate both ms and sl parameters Cancel It is possible in this menu to reset the factory settings or to cancel radio controls present in the memory Enter in the cancel menu chose the parameter with arrows buttons and confirm with the E ENTER button Exit keeping pressed the E ESC button for about 2 seconds e Parameter reset to reset all regulating and functions values to the factory settings go on the reset parameter wording and press the E ENTER button The rese message is shown on the display it flashes until the decision to reset all the parameters is co
37. to della barriera Collegare l alimentazione 24V sia del trasmettitore che del ricevitore delle fotocellule all uscita predisposta per il lampeggiante en funzionamento encoder gestisce il funzionamento del motore con encoder In caso di guasto dell encoder la barriera si blocca poco dopo la sua partenza e sul display viene visualizzata la scritta encl possibile disattivare questa funzione e permettere al motore di effettuare ulteriori manovre a uomo presente cio mantenendo in pressione il tasto START CLOSE o OPEN ATTENZIONE il funzionamento del sistema senza l encoder da considerarsi una gestione di emergenza In questa modalit ogni ostacolo incontrato dal motore comanda l arresto del movimento senza la sua inversione ss soft start permette al motore di effettuare una partenza dolce e a velocit ridotta per diminuire la sollecitazione delle parti meccaniche dell impianto Attivando questa funzione il motore eroga una forza minore nella sua fase di partenza oc funzionamento open close l ingresso in morsettiera di START diventa CLOSE In questa Modalit un comando apre la barriera e l altro lo chiude cf funzionamento della ricevente integrata a codice fisso se attivo la ricevente funziona con i codici fissi 3c terzo canale radiocomando se attivo alla pressione del terzo canale del radiocomando il contatto del rel ausiliario si chiude per il tempo impostato nel parametro rel ricordarsi di aver me
38. usura AI termine della fase di apprendimento sul display sar visualizzato ok nel caso di corretta programmazione o err nel caso vi siano stati degli errori Per uscire dalla programmazione premere il tasto di selezione E ENTER Impostare correttamente i livelli di forza antischiacciamento in apertura e in chiusura nel menu che devono essere superiori ai valori massimi visualizzati durante l apprendimento ATTENZIONE questa regolazione pu influire sul grado di sicurezza dell automazione Durante le manovre di apprendimento la centrale ignora i comandi di START OPEN CLOSE e lavora con i parametri di forza al massimo Anche se rimangono attive le sicurezze assicurarsi che non vi siano oggetti o persone sulla traiettoria di lavoro della barriera Effettuare alcuni cicli di prova verificando il corretto funzionamento di tutto l impianto Effettuare le misure della forza di impatto della barriera secondo quanto specificato dalle norme EN12445 Leggi codice possibile verificare se un radiocomando gi stato memorizzato oppure leggere il codice di un nuovo telecomando verificando cos la compatibilit con la centrale Per effettuare tale operazione entrare nel sottomenu leggi codice tramite il tasto E ENTER Quando sul display verr visualizzato il messaggio premi premere il tasto del trasmettitore che si desidera verificare prima schermata Sr0 oppure SfOloppure 101 oppure f01 ecc Il primo carattere indica il produttore
39. viduata come spazio di battuta In questa zona la sicurezza encoder o amperometrica verr rilevata come fine corsa e non come ostacolo Il valore impostato di default 10 e pu essere regolato da 5a 20 e chr tempo di chiusura rapida il tempo di chiusura automatica nel caso in cui vi sia un passaggio attraverso le fotocellule durante la fase di apertura o a barriera aperta il tempo della regolazione ttca se attivato e Maggiore di chr viene automaticamente ridotto al tempo ch r impostato Il valore di default 3 e pu essere impostato da I a 10 sec e rel tempo rel ausiliario il tempo durante il quale il contatto del rel ausiliario rimane chiuso dopo che la barriera si chiusa In caso di parametro 3c attivo questo valore indica quanti secondi rimarr chiuso il contatto rel ausiliario dopo che si premuto il terzo canale del radiocomando Funzioni Le regolazioni dei parametri si effettuano entrando nel sottomenu funzioni Scegliere il parametro da modificare tramite i tasti freccia e premere E ENTER per visualizzare se la funzione attivata 1 o se disattivata 0 Per modificare lo stato premere i tasti freccia Successivamente confermare tramite il tasto E ENTER e uscire tenendo premuto il tasto E ESC per circa 2 secondi e ca chiusura automatica chiusura automatica della barriera dopo la sua completa apertura Impostare la regolazione ttca per personalizzare il tempo che deve intercorrere tra la fine d
Download Pdf Manuals
Related Search
Related Contents
"user manual" Printer Administration Utility 4.2 Owner`s Manual - BrandsMart USA Lowrance Endura (Safari) Operation Manual Mapefloor I 300 SL Mapefloor I 300 SL Wellcraft 020601290 Installation Guide Copyright © All rights reserved.
Failed to retrieve file