Home

41533 Man off IS2500-5501 - Mase Generators of North America

image

Contents

1. Code E 80 This code indicates that the group has stopped due to a complete lack of voltage OV Display of this code means that the control panel is not able to read the voltage in the alternator due to a break in an electrical connection the alternator is damaged Code E 81 This code indicates that the group has stopped because the pressure in the motor lubrication system is insufficient Code E 82 This code indicates that the group has stopped because the motor is too hot Code E 83 This code indicates that the group has stopped because the alternator is too hot Code E 85 This code indicates that the group has stopped because the voltage has dropped to under 70 of the rated value for over 15 seconds Code E 87This code indicates that the group has stopped because 30 after start up the voltage in the generator group has not reached 80 of the rated voltage This may be because the engine revs are too low or because the alternator is broken Code batt This code indicates that the battery voltage is too low When this code appears the generator group is not stopped 19 4 9 6 Scanbiatoredi calore aria acqua Caratteristiche Libero da incrostazioni Metodo di controllo Distaccare i tubi acqua Fig 17 Rif 1 2 Togliere le viti Fig 17 Rif 3 e rimuovere lo scambiatore Verificare visivamente 4 9 6 Heat exchanger air water Characteristics Fouling free Testing method Disconnect the w
2. vuoto 52 52 5 Hz 225 230V 110 115V 50 51 Hz 215 220V 105 110V vuoto 62 62 5 Hz 245 250V 120 125V 60 56 Hz 235 240V 115 120V Poiche gli alternatori MASE sono del tipo a due poli vale la corrispondenza 1Hz gt 60 giri min 3000 giri min gt 50Hz 3600 giri min gt 60Hz Metodo di controllo Verificarela frequenza all uscita dei morsetti di potenza con uno strumento idoneo frequen zimetro a lamelle o digitale Per una lettura corretta dei valori di tensione ed amperaggio utilizzare solo strumenti a vero valore efficace RSM RIMEDIO Allentare la vite Fig 28 Rif 1 2 Ruotare le staffe sino al raggiungimento del n dei giri quindi bloccare le viti N B Poiche la tensione generata dal gruppo e proporzionale alla frequenza verificare il nume ro dei giri del motore quale possibile causa di anomalie di tensione IMPORTANTE Poiche la taratura del numero di giri del motore viene eseguita e quindi bloccata in sede di collaudo si consiglia in generale di intervenire sulla stessa Laindicazioni date qui sono riferite ad interventi di prima necessit a cui dovr far seguito un controllo del motore A titolo indicativo fra le possibili cause di basso rendimento del motore si consiglia di verificare l eventualita di filtro aria o filtro nafta intasati iniettori difettoso od otturato 4 9 16 Engine speed adjustment Characteristics no load 52 52 5Hz 225 230V 110 115V 50 51 Hz 215 220V 105 11
3. GENERATORS IS 2500 IS 3500 3501 IS 4500 4501 IS 5500 5501 MANUALE DI SERVIZIO SERVICE MANUAL M OFF 1IS2500 INDICE 1 CARATTERISTI CHE TECNICHE 1 1 Motore Alternatore Dimensioni 1 2 Identificazione del generatore Numero matricola del generatore numero matricola del motore 1 3 Identificazione dei componenti 1 4 Cruscotto comandi 2 Motore 3 Principio di funzionamento 4 Controlli 4 1 Avvolgimento di eccitazione 4 2 Avvolgimento di potenza A3 Avvolgimento di carica batteria 44 Fusibile carica batteria 4 5 Interruttore termico 4 6 Avvolgimento di rotore 4 7 Diodi di rotore 4 8 Condensatore 4 9 Scheda rele 4 9 1 Fusibile 4 9 2 Rele 4 9 3 Diodi 1000V 1A 4 9 4 Diodi 600V 6A 4 9 5 Circuito stampato 4 9 6 Scambiatore di calore 4 9 7 Anodo di zinco 4 9 8 Elettrovalvola 4 9 9 Pompa gasolio 4 9 10 Termostato acqua 4 9 11 Pressostato olio 4 9 12 Sonda A T T 4 9 13 Motorino avviamento 4 9 14Cinghia pompa acqua 4 9 15 Pompa acqua 4 9 16Regolazione dei giri 5 Tabella guasti 6 Schema elettrico 1 TECHNICAL FEATURES 1 1 Engine Alternator Dimensions 1 2 Identification of generator Generator serial number Engine serial number 1 3 Identification of components 1 4 Control panel 2 Engine 3 Principle of power generation 4 Service 4 1 Excitation winding 4 2 Power excitation 4 3 Battery charger winding 4 4 Battery charger fuse 4 5 Alternator thermostat 4 6 Rotor winding 4
4. INGRESSO CAVI ELETTRICI INGRESSO ACQUA TAPPO CARICO OLIO SCAMBIATORE DI CALORE TERMOSTATO ACQUA PRESSOSTATO OLIO Generator components Fig 5 ENGINE ALTERNATOR ALTERNATOR CONTROL PANEL FUEL SOLENOID WATER PUMP FUEL RETURN STOP LEVEL DEEP STICK OIL FUEL PUMP FUEL FEED INPUT WATER CONNECTIONS AIR INLET INLET ELETTRIC CONNECTIONS INLET WATER OIL FILLING WP HEAT EXCHANGER WATER TEMPERATURE SWITCH OIL PRESSURE SWITCH 1 4 CRUSCOTTO COMANDI 1 CONTAORE 2 PULSANTE OFF 3 PULSANTE START 4 PULSANTE ON 5 LED PANNELLO ON VERDE 6 LED USCITA GENERATORE VERDE 7 LED PRESSIONE OLIO ROSSO 8 LED TEMPERATURA MOTORE ROSSO 9 LED TEMPERATURA GENERATORE ROSSO 1 4 CONTROL PANEL 1 HOURSMETER 2 OFF BUTTON 3 START BUTTON 4 BUTTON ON 5 PANEL ON LED GREEN 6 GENERATOR OUTPUT LED GREEN 7 OIL PRESSURE LED RED 8 ENGINE TEMPERATURE LED RED 9 GENERATOR TEMPERATURE LED RED 5 6 lg gt 8 Q 9 QJ 2 MANUTENZIONE Per la durata e il corretto funzionamento del generatore necessario rispettare il programma di controlli e manutenzione indicati nella tabella seguente L esecuzione di queste operazioni descritta per la parte relativa al motore sul libretto uso e manutenzione o sul manuale d officina del costruttore del motore Si ricorda inoltre che durante le normali opera zioni di manutenzione Montaggio smont
5. up to 3 times the rated amperage As we know this initial rush typical of this alternator is extremely important to start asyn chronous motors 4 CONTROLLI Tutte le misure di resistenza si intendono ese guite ad alternatore freddo temperatura am biente 10 30 C e con strumentazione tale da permettere la lettura dei valori indicati La tolleranzarispetto ai valori riportati indica tivamente 10 letture approssimative eseguite con strumenti di portata non adeguata possono unicamente indicare la continuit dell avvolgimento ma non danno indicazioni su eventuali corto circuiti N D Oltre alle possibilit di guasto che sono indicate in seguito si pu presentare il caso di uno o pi avvolgimenti a massa Si consiglia quindi di controllare questa eventualit verificando con un tester che non ci sia continuit fra le estremit dei vari avvolgimenti identificati nei paragrafi successivi e massa 4 1 Avvolgimento di eccitazione TS 3 80 Ohm IS 3500 1 2 37 Ohm 1 86 Ohm Metodo di controllo Scollegare dal condensatore i due cavi BLU provenienti dallo statore Fig 3 Verificare che la resistenza fra le estremita dei due cavi rientri nei valori indicati in tabella RIMEDIO Sostituire lo statore 10 4 SERVICE All the resistances must be measured when the alternatoris cold ambienttemperature between 10 30 C and with an instrument that allows reading of given values The
6. NS Testing method Disconnect the wires of the rotor winding Verify that the resistance value between the wire terminals is as reported in the table above Fig 8 REMEDY Replace the rotor WARNING If there is still no power it could depend very rarely on the dissipation of the residual magnetism of the rotor So as to solve the problem it is advisable to connecta 12 V battery to the capacitor terminals or to the powerterminals forafew instants while the generator is running The rotor will get magnetized immediately 13 4 7 Diodi di rotore Caratteristiche 21A800V Direzione normale 0 66 Ohm Direzione inversa Mancanza di cont Metodo di controllo Scollegare il cavo dal diodo Verificare che la resistenza fra e massa rientri nei valori indicati Fig 9 Verificare che invertendo i puntali del tester non ci sia continuit RIMEDIO Sostituire il diodo N B In caso di diodo difettoso necessario sostituire anche il varistore Fig 9 Rif 1 anche se apparentemente integro 4 8 Condensatore Caratteristiche G1 teristics IS 2500 12 5 microfarad 500 V IS 3500 11 20 microfarad 500 V IS 4500 1135 microfarad 500 V IS 5500 11 35 microfarad 500 V 4 7 Rotor diodes Caracteristics 21 A800V Normal direction 0 66 Ohm Reverse direction No continuity Testing method Disconnect the wire from the diode Verify that the resistance value between and groun
7. 7 Rotor diode 4 8 Capacitor 4 9 Printed circuit relay 4 9 1 Fuse 4 9 2 Relay 4 9 3 Diode 1000V 1A 4 9 4 Diode 600V 6A 4 9 5 Printed circuit 4 9 6 Heat exchanger 4 9 7 Zinc anodes 4 9 8 Stop solenoid 4 9 9 Diesel pump 4 9 10 Water temperature switch 4 9 11 Oil pressure switch 4 9 12 A T T Device 4 9 13 Starter 4 9 14Belt of the water pump 4 9 15 Water pump 4 9 16Engine speed adjustment 5 Trouble shooting table 6 Wiring diagram 1 CARATTERISTICHE TECNICHE TECHNICAL FEATURES 1 1 MOTORE ALTERNATORE DIMENSIONI ENGINE ALTERNATOR DIMENSION MOTORE ENGINE Yanmar Yanmar Yanmar Modello Model L48 AE L70AE L100AE Monocilindrico a scoppio 4 tempi 1cylinder 4 stroke internal diesel raffreddato ad aria combustion air cooled diesel Cilindrata Displacement 211cc 296 cc 406 cc Giri minuto R P M 3000 3600 3000 3600 3000 3600 Alesaggio per corsa Bore for stroke 70 X 55 78 X 62 86 X 70 Potenza Hp Power Hp 3 8 4 3 4 2 4 7 5 5 6 1 6 0 6 7 7 7 8 8 9 10 Consumo g Hp h Fuel consumption g Hp h 220 230 220 230 220 230 Alimentazione Fuel DIESEL DIESEL DIESEL Sistema di avviamento Starting system ELETTRICO ELETTRICO ELETTRICO Capacita olio Oil capacity 0 8 It 1 1 It 1 1 lt Inclinazione massima Max inclination 20 20 20 ALTERNATORE ALTERNATOR Sincrono monofase autoeccitato Synchronous self excited d
8. Metodo di controllo Verificare che a motore spento ci sia continuita fra il positivo e massa Fig 22 Verificare che accendendo il motore con l olio alivello si interrompa la continuita fra il positi vo e massa 1 RIMEDIO Sostituire il pressostato IMPORTANTE 11 pressostato olio non da un indicazione esatta del livello olio E indinspensabile quindi un controlloperiodico Sh perevitare danni al motore 4 9 10 Water temperature switch Characteristics The contact is normally open The contact is closed at T gt 70 C 3 C Testing method Verify that there is no continuity between and ground Fig 21 Put the termostat in water at 70 C and check if the contact closes REMEDY Replace the thermostat 4 9 11 Oil pressure switch Characteristics Contact normally CLOSED Contact OPEN P 1ATM Testing method Check if there is continuity between and ground when the engine isnot running Fig 22 Check if there is no continuity between and ground when the engine is running and the oil is at the right level REMEDY Repalce the pressure switch ARNING The pressure switch doesnt provide exact indication about the oil level A periodic check 8h of the oil level is indispensable to prevent the engine from blowing up 23 4 9 12 SondaA T T Alta Temperatura Testa Caratteristiche Contatto normalmente aperto Contatto chiuso a 115 C 3 C Metodo di controllo Verificar
9. tolerance against the reported values is around 10 Readings taken with simpler instruments can only indicate the continuity of the winding but cannot indicate the presence of short circuits NB Apart from the possibilities suggested here by one or more windings could also be grounded causing a failure We suggest therefore to check by means of a tester that there is no continuity between the extremities of the windings and ground 4 1 Excitationwinding Testing method Disconnect from the capacitor the two wires color BLUE coming from the stator Fig 3 Verify that the resistance values between these two wire terminals are within the limits as reported in the table above REMEDY Replace the stator Metodo di controllo Scollegare dalla morsettiera 1 cavi di potenza contrassegnati dalle lettere P F P F Fig 4 Verificare che la resistenza fra le estremit di entrambe le coppie di cavi P F e P F rientri nei valori indicati in tabella N B La resistenza totale dell avvolgimento nel collegamento 220 V o 240 V si misura ponticellando F eP La misura effettuata fra 1 punti P e F sar il doppio del valore indicato in tabella RIMEDIO Sostituire lo statore 4 3 Avvolgimentodi caricabatteria HA 0 10 Ohm 13 V eel Ee 0 10 Ohm 13 V S 4500 1 0 10 Ohm 13 V S 5500 1 0 10 Ohm 13 V Metodo di controllo Scollegare i cavi dal regolatore Fig 5 e verificare che laresi
10. 0V no load 62 62 5 Hz 245 250V 120 125V 60 56 Hz 235 240V 115 120V Since the alternator is atwo pole type 1Hz gt 60 R P M 3000 R P M gt 50Hz 3600 R P M gt 60Hz Testing method Verify the frequency at power terminals using a suitable instrument vibrating reed or digital frequency meter Correct readings of voltage and amperage are abtained only by emploving instruments with true effective value REMEDY Slack the screw Fig 28 Rif 1 2 Rotate the levers up to reach RPM then block the screws N B Since voltage is proportional to the frequency ifand when there is voltage anomalies check the RPM PORTANTE Since RPM is adjusted and blocked during the testing phase it s advisable not to modify it The above instruction should be followed by a check up of the engine For your informations when looking for causes leading to low efficency it is advisable to verify air filter fuel filter choking defective holed injection 5 TABELLA GUASTI 5 TROUBLE SHOOTING COMPLAINT PROBABLE REASON Defective starting buttons Pe Defective fuel solenoid ele Defective battery Battery CEE cable section Defective starting motor Lo i Ils Piping fuel filter choked GEE 12V circuit fuse UNSTABLE RUNNING E WHITE SMOCKE E BLACK SMOCKE DOES NOT START AND Avv Ev rela Aesse Too much olincranicase Jelef Safety device intervention e e overs Le Detective govemori
11. 12 V to terminals 85 and 86 makes terminals 30 and 87 CLOSE and terminal 30 and 87b OPEN REMEDY Replace the relay 4 9 3 Diodes Caracteristics 1A1000V Normal direction 0 850 Ohm Reverse direction No continuity Testing method Remove the relays Disconnect the wires from the terminal board Verify that the resistance value between the diode s terminal is as reported above Invert the tester prods and verify that there is no continuity in REMEDY Replace the diode 4 9 3 Diodi Caratteristiche 6A 600V 4 9 3 Diodes Characteristics 6A 600V Normal direction 0 75 Ohm Reverse direction No continuity Direzione normale 0 75 Ohm Direzione inversa Mancanza di cont Metodo di controllo Verificare che la resistenza fra le due estremita rientri nei valori indicati Fig 15 Verificare che invertendo 1 puntali del tester non ci sia piu continuita RIMEDIO Sostituire il diodo Testing method Verify that the resistance value between it s terminals is as reported above Fig 15 Invert the tester terminals and verify that there is no continuity in the reverse REMEDY Replace the diode 17 4 9 5 Circuito stampato Metodo di controllo Verificare tutte le funzioni del generatore av viamento arresto dispositivi di sicurezza Verificare le possibili cause di mancato funzionamento batteria motorino avviamen to pressostato termostato interruttore termi co fusibil
12. LTRE ACEITE FILTRO COMBUSTIBILE FUEL FILTER FILTRE COMB KRAFTSTOFFILTERPATRONE FILTRE COMBUSTIBLE REMPLACEMENT WECHSEL SUSTITUCION CINGHIA BELT COURROIE GEBLASERIEMEN CORREA Fig Abb 6 Rif ref r f Nr 2 SOSTITUZIONE REPLACEMENT UBSTITUTION SEGMENT DE PIST SETSUNG DER SPANNENDEN KOLBENRING SUSTITUC ELASTICAS PISTON REVISIONE OVERHAUL REVISION OBERHOLUNG REVISION SMERIGLIATURA VALVOLE LAP VALVES POLISSAGE SOUPA PES EINSCHLEIFEN DER VENTILE ESMERILADO VALVULAS DT FASCIE ELASTICHE PISTONE REPLACEMENT OF PISTON S LASTIC BANDAGES N ER FAJAS PRIMA SOSTITUZIONE FIRST REPLACEMENT PREMI RE REMPLACEMENT ERSTE WECHSEL PRIMERA SOSTITUCI N 1 PRINCIPIO DI FUNZIONAMENTO I generatori della serie IS 2500 sono dotati di alternatori senza spazzole sincroni a due poli autoregolati autoeccitati con condensatore Fig 1 Rif 5 collegato con l avvolgimento ausiliario di statore Fig 1 Rif 3 Gli alterna tori generano una tensione alternata disponibi le al morsetti dell avvolgimento principale Fig 1 Rif 4 a una frequenza di 50 60 Hz Corri spondenti ad una velocit del motore primo di 3000 3600 giri secondo il principio di seguito descritto All avviamento il magnetismo di rotore ma gnetismo residuo del nucleo induce nell avvol gimento ausiliario di e
13. TERNAL OIL FILTER FILTRE HUILE meration and PULIZIA DEL GRUPPO GENERATOR CLEANING NETTOYAGE DU GROUPE STROMERZEUGERSREINIGUNG LIMPIEZA DEL GENERADOR REINIGUNG LIMPIEZA position PULIZIA CIRCUITO ACQUA WATER CIRCUIT CLEANING NETTOYAGE DU CIRCUIT EAU WASSERKREISREINIGUNG LIMPIEZA CIRCUITO AGUA LIVELLO OLIO MOTORE KRANKCASE OIL LEVEL NIVEAU CARTER HUILE OLSTAND MOTOR NIVEL ACEITE MOTOR PULIZIA CLEANING NETTOYAGE LIQUIDE DE BATTERIE SAURESTAND DER BATTERIE NIVEL LIQUIDO BATERIA BOCCOLA ROTORE ROTOR BUSHING DUILLE ROTOR LAUFER BUCHSE ARANDELA ROTOR LIVELLO LIQUIDO BATTERIA BATTERY WATER LEVEL NIVEAU CONTROLLO CIRCUITO ACQUA WATER CIRCUIT CONTROL CONTROL CIRCUIT EAU WASSERKREISKONTROL CONTROLO CIRCUITO AGUA ANODI DI ZINCO ZINC ANODES PASTILLES DE ZINC ZINC ANODE PASTILLAS CINCICO GEBLASERIEMENSPANNUNG TENCI N CORREA TENSIONE CINGHIA BELT TENSION TENSION COURROIES D ET CALBUT VENTILSPIEL HUELGO VALVULAS CONTROLLO CHECK VERIFICATION KONTROL CONTROLO OLIO CARTER SOA OIL CARTER HUILE MOTOR OL ACEITE CARTE GIOCO VALVOLE ROCKER AARMS CLEARANCE JEU SOUPAPES SERRAGGIO RACCORDO MANDATA COMB TIGHTEN FUEL DELI VERY UNION SERRAGE RACC DEBIT COMB DRUCKROHRA SCHLUSS MOMENTO TORSION JUNTURA ENVIO COMBUSTIBLE N FILTRO OLIO OIL FILTER FILTRE A HUILE OLFILTER FI
14. ag gio necessario rispettare alcune regole gene rali quindi rispettare le coppie di serraggio utilizzare grassi olii frenafiletti appropriati non lavare avvolgimenti o parti elettriche con acidi o sostanze corrosive spruzzare disossidanti sui contatti elettrici rispettare la numerazione deicavi Se necessario annotarne la numerazione e la posizione MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N 2 MAINTENANCE For the longevity and correct performance of the generator it is necessary to respect the check and maintenance program detailed out in the following tables As regarding the engine the maintenance op erations are described in the use and mainte nance manual and the workshop manual pre pared by the engine manufacturer Please note further that while involved in nor mal maintenance work of the generator Dis mounting mounting certain general rules must be adhered to respect the torque specifications use appropriate oil grease and bonding agents do not clean windings or electrical parts with acid or other corroding substances spray deoxidizer on the electrical contact points respect the numerical or der of wires PERIODICIT ORE HOURS HEURES STUNDEN HORAS INIETTORI INJECTORS INJECTEURS EINSPRITZDUSE INYECTORES If necessary note their nu INTERIEUR INNERE OLFILTER FILTRE ACEITE INTERNO A FILTRO OLIO INTERNO IN
15. ater hoses Fig 12 Ref 1 2 Remove the screws fig 17 Ref 3 and the heat exchanger Verify visually RIMEDIO Immergere lo scambiatore in una soluzione di acqua 90 e acido cloridico 10 alla temperatura di 10 C Sostituire se necessa rio 20 REMEDY Wash exchangerimmerging it ina water 90 and hydrochloric acid 10 solution at 50 C temperature Replace it if necessary 4 9 7 Anodo di Zinco 4 9 7 Zinc anode Caratteristiche Consumo regolare Characteristics Regular consumption Metodo di controllo Testing method Controllare visivamente Check visually Svitare e togliere il tappo Fig 18 Rif 1 Unscrew and remove the complete plugs fig 18 Ref 1 RIMEDIO Sostituire lo Zinco REMEDY Replace the Zinc 4 9 8 Elettrovalvola 4 9 8 Stop solenoid Caratteristiche 12V normalmente chiusa Characteristics 12V normally closed resistenza bobina 18 3 ohm coil resistance 18 3 ohm Metodo di controllo Testing method Scollegare il fast on Fig 19 Rif1 Disconnect the fast on terminal Fig 19 Ref 1 Verificare che la resistenza dell avvolgimento Verify that the resistance value between the fra il fast on e massa abbia il valore indicato fast on terminal and groundis as reported above RIMEDIO Sostituire l elettrovalvola REMEDY Replace the fuel solenoid 21 4 9 9 Pompa Gasolio Caratteristiche 12V Metodo di controllo Scollegare i cavi Verificare il funzionamento con una bat
16. ato la resistenza dell avvolgimento ed il fusibile di consiglia di sostituire il regolatore TI as 20 amp 20 Amp T as 30 Amp 30 Amp IS 4500 1 30 Amp IS 5500 1 30 Amp Metodo di controllo Verificare la continuit alle estremit del fusi bile Fig 6 Rif 1 RIMEIDO Sostituire il fusibile 4 5 Interruttoretermico statore Caratteristiche Normalmente chiuso Temperatura d interven to 160 C 12 N B The above measurements must be done after few minutes from the starting without any load applied to the generator and with the starting battery connected REMEDY Replace the stator WARNING The battery charger circuit equipped with an electronic charger regulator has a max output of 15 A at 12 V If the defect on the battery charger circuit results not to depend on the fuse or on the stator windings it s advisable to replace the regulator Testing method Verify the continuity at its terminals Fig 6 Ref 1 REMEDY Replace the fuse 4 5 Thermal switch stator Characteristics Normally closed Trips at a temperature of 160 C Metodo di controllo Scollegare dalla morsettiera i due cavi NERI provenienti dallo statore ai morsetti N 17 e N 18 Fig 7 Verificare la continuit fra le due estremit dei cavi RIMEDIO Sostituire lo statore N B L interruttore termico pu intervenire per sovraccarico o per sovratemperatura Verificare quindi s
17. ccitazione Fig 1 Rif 3 una tensione Questa tensione applicata al condensatore Fig 1 Rif 5 e fa circolare nel circuito chiuso costituito dal condensatore e dall avvolgimento ausiliario una corrente capacitiva Questa corrente produce un campo magnetico che rafforzail magnetismo di rotore generando in esso una tensione che raddrizzata dai diodi Fig 1 Rif 2 facircolare una corrente continua negli avvolgimenti induttori Fig 1 Rif 1 Il campo magnetico rotante dovuto alla circola zione di questa corrente genera a sua volta nell avvolgimento principale Fig 1 Rif 4 la tensione nominale ai morsetti del generatore I valori intesi come percentuale dei valori nominali di tensione e corrente disponibili ai morsetti hanno l andamento riportato nel dia gramma Fig 2 Come si pu notare possibile prelevare corrente fino al valore nominale a tensione praticamente costante 5 Ed inoltre l alternatore ad una tensione non infe riore al 70 75 del valore nominale ancora in grado di fornire una corrente di picco pari a circa 3 volte il valore nominale Questa caratteristica tipica di questo alternato re particolarmente utile nella fase di avvia mento dei motori elettrici asincroni 3 PRINCIPLE OF POWER GENERATION IS 2500 generators are equipped with two pole synchronous brushless alternators These alter nators are also self regulating and self exciting with capacitor Fig 1 Ref 5
18. connected to the auxiliary winding of the stator Fig 1 Ref 3 The alternators generate an alternating voltage at the terminals of the main winding Fig 1Ref 4 having a frequency of 50 or 60 Hz Depend ing on whether the engine runs at 3000 or 3600 R P M The generation of current is in accordance with the principle described here below On starting the unit the magnetic force of the rotor residual magnetism of the nucleus in duces a voltage in the auxiliary winding of excitation Fig 1 Ref 3 This voltage is fed to the capacitor Fig 1 Ref 5 which creates a capacitive current circulating in the closed cir cuit constituted of the capacitor and the auxil lary winding This capacitive current creates amagnetic field reinforcing the magnetism of the rotor thus creating in it a voltage which rectified by the diodes Fig 1 Ref 2 makes a D C current circulate in the induction windings Fig 1 Ref 1 As aresult of which arotating magnetic field is created which generates the rated output in the principal winding Fig 1 Ref 4 and which can be tapped at the terminals The voltage and current values denoted in percentage terms of rated values are as shown in the diagram Fig 2 As you will note itis possible to get energy up to the nominal value With voltage practically constant 5 Moreover the alternator at a voltage not inferior to 70 75 of the rated voltage is able to furnish as initial power rush
19. d is as reported in the table above Fig 9 Invert the tester terminals and verify that there is no continuity in the reverse direction REMEDY Replace the diode N B If the diode is defective it is necessary to replace the varistor too Fig 9 Ref 1 even if it appears intact 4 8 Capacitor Metodo di controllo Scollegare i cavi BLU dal condensatore Posizionare il tester sul valore pi alto della scala ohmica x1000 la lancetta dovr oscilla re velocemente avanti e indietro nel momento in cui i puntali del tester toccheranno 1 terminali del condensatore Fig 10 14 Testing method Disconnect the wires colour BLUE of the capacitor With the tester set to x1000 connect it with the capacitor terminals The needle must swing sharply away an back the moment the tester prods touch the capacitor terminals Fig 10 N B Con questa prova si verifica che il con densatore non sia in cortocircuito o interrotto Una diminuzione di capacit che ha come effet to una diminuzione della tensione a vuoto difficilmente valutabile In questo caso verificate le altre possibili cause si consiglia di sostituire il condensatore RIMEDIO Sostituire il condensatore 4 9 Scheda rel 1 Fusibile 1 A Fuse 1 A 2 Rel elettrovalvola e pompa nafta Fuel solenoid and fuel pump relay 3 Rel avviamento Start relay 4 Diodi Diodes Metodo di controllo Verificare la continuit alle es
20. e necessario i carichi ap plicati e la temperatura d esercizio del generato re con particolare attenzione alla sua installa zione 4 6 Avvolgimento di rotore n 2 Caratteristiche Caracteristics ee cone 050 onm 0 50 Ohm Tag 057 ohm 0 57 Ohm IS 4500 1 0 74 Ohm IS 5500 1 0 74 Ohm Metodo di controllo Scollegare le estremit dell avvolgimento di rotore Verificare che la resistenza fra le due estremit rientri nei valori indicati Fig 8 RIMEDIO Sostituire lo statore IMPORTANTE La mancanza di tensione in uscita pu essere causata eccezionalmente dalla mancanza o insufficienza di magnetismo residuo del rotore Come primo intervento si consiglia con il generatore in moto di collegare perun attimo una batteria 12 Vai terminali del condensatore o all uscita di potenza In questo modo il rotore viene istantaneamente magnetizzato Testing method Disconnect from the terminal board the two wires colour Black connecting terminals No 17 and 18 Fig 7 to the stator Check that there is continuity between the two ends of the two wires REMEDY Replace the stator N B The thermal switch can trip because of overload or overheat It s hence important to verify the loads connected and the running temperature of the generator with an eye on installation to verify if it may have contributed to the problem 4 6 Rotorwinding no 2 a e gt T m dr lt e
21. e scheda rele RIMEDIO Sostituire il circuito stampato Fig 16Rif 1 4 9 5 Printed circuit Testing method Verify all generator s functions start stop safety devices Verify all the possible causes of not proper running battery starter oil pressure switch water temperature switch alternator thermo stat relay board fuse REMEDY Replace the printed circuit Fig 16 Ref 1 Quando il gruppo si arresta per l intervento di una protezione sul display del pannello comandi scompare l indicazione delle ore di funzionamento e compare un codice ad indi care la causa dell arresto del gruppo elettrogeno Nella tabella sono riportati tutti i codici e il loro significato When the unit stops because of an alarm intervention the operating time indication disappears from the control panel display and a code appears to indicate the cause of the generator stop In the table below all the codes and their meaning are listed TABELLA CODICI DI ALLARME CODICE CAUSA INTERVENTO PROTEZIONE TABLE OF ALARM CODES REASON FOR ALARM E 80 Mancanza tensione gruppo E 81 Bassa pressione olio E 82 Alta temperatura motore E 83 Alta temperatura alternatore E 85 Sovraccarico gruppo elettrogeno E 87 A 30 sec dall avvio il gruppo non raggiunge 80 della tensione nominale batt Bassa tensione di batteria 18 No power to genset Oil pressure low Motor temperature high Alter
22. e che non ci sia continuita fra il posi tivo e massa Fig 23 RIMEDIO Sostituire il termostato 4 9 13 Motorino avviamento Caratteristiche 12V 0 8 KW Metodo di controllo Scollegare i cavi Utilizzare una batteria 12V collegando il della batteria con il morsetto a vite ed il a massa carcassa del motorino Fig 24 Verificare che il motorino giri facendo un ponte fra il morsetto a vite motorino avvia mento ed il fast on adiacente Fig 24 Rif 1 24 4 9 12 E H T Device Engine high temperature Characteristics The contact is normally open The contact is closed at 115 C 3 C Testing method Verify that there is no continuity between and ground Fig 23 REMEDY Replace the thermostat 4 9 13 Starter Characteristics 12V 0 8 KW Testing method Disconnect the wires Connect a 12V battery pole with the screw clamp and pole to the body of the starter Fig 24 Connect the screw clamp and the adiacent fast on and verify if the starter is running well Fig 24 Ref 1 4 91 4 Cinghia pompa acqua Caratteristiche Characteristics IS2500 50Hz Z21 10x545 60 Hz Z22 10x560 IS 3500 1 50 Hz Z23 10x585 60 Hz Z24 10x610 IS 4500 1 50Hz Z24 10x610 IS 5500 1 60Hz Z25 10x635 Metodo di controllo Premere con circa 10Kg sulla cinghia verifica re che la flessione non superi 0 5cm Fig 25 RIMEDIO Tendere la cinghia allentare i bul loni di fissaggio pom
23. nator temperature high Generator set overloaded After 30 s from start up the genset has not reached 80 of rated voltage Battery voltage low Cod E 80 Tale codice indica che il gruppo si arrestato per mancanza completa di tensione 0V La comparsa di tale codice sta ad indi care che il pannello di comando non in grado di leggere la tensione del l alternatore per l in terruzione di una connessione elettrica che l alternatore danneggiato Cod E 81 Tale codice indica che il gruppo si arrestato per pressione dell impianto di lubrificazione del motore insufficiente Cod E 82 Tale codice indica che il gruppo si arrestato perch il motore ha raggiunto tem perature troppo elevate Cod E 83 Tale codice indica che il gruppo si arrestato perch l alternatore ha raggiunto temperature troppo elevate Cod E 85 Tale codice indica che il gruppo si arrestato perch la tensione scesa sotto il 70 del valore nominale per un tempo supe riore a 15 s Cod E 87 Tale codice indica che il gruppo si arrestato perch la tensione del gruppo elettrogeno dopo 30 s dall avviamento non ha raggiunto 80 del valore nominale Tale incon veniente pu essere causato da un numero di giri del motore insufficiente o un guasto all al ternatore Cod batt Tale codice indica che la tensione di batteria insufficiente La comparsa di que sto codice non arresta il gruppo elettrogeno
24. niage Jel Wormvalve guides lef Biockedwales def Worm cvinder and position rings e Detective nestor lef fel Defeciie gege pg e e eo fel petoctve reecinopumo delel 28 6 SCHEMA ELETTRICO 6 WIRING DIAGRAM ai E EE EE e o ee L 11 Mi E AAA Lee i A gt gt gt E 13 El ua 12 a E z T 0 ES e BN e N 5 GL ae ES al eee p HE 32M 1 H 14 90 Hr 19 18 17 16 15 DA AS i DESCRIZIONE DESCRIPTION 1 ROTORE 1 ROTOR 2 STATORE 2 STATOR 3 DIODO 3A 3 DIODE 3A 4 VARISTORE 4 VARISTOR 5 SCHEDA RELAY 5 PRINTED CIRCUIT RELAY 6 MORSETTIERA DI POTENZA 6 POWER TERMINAL BOARD 7 MORSETTIERA CIRCUITO RELAY 7 RELAY CIRCUIT TERMINAL BOARD 8 MOSETTIERA PANNELLO COMANDI 8 CONTROL PANEL TERMINAL BOARD 9 FUSIBILE 1A 9 FUSE 1A 10 CONDENSATORE 10 CAPACITOR 11 REGOLATORE CARICA BATTERIA 11 BATTERY CHARGER REGULATOR 12 FUSIBILE 12 FUSE 13 MOTORINO AVVIAMENTO 13 STARTER 14 BATTERIA 14 BATTERY 15 POMPA COMBUSTIBILE 15 FUEL PUMP 16 ELETTROVALVOLA STOP 16 FUEL SOLENOID 17 PRESSOSTATO OLIO 17 OIL PRESSURE SWITCH 18 TERMOSTATO TESTATA MOTORE 18 OVERHEAD ENGINE THERMOSTAT 19 TERMOSTATO ACQUA 19 WATER TERMOSTAT 20 TERMOSTATO ALTERNATORE 20 ALTERNATOR THERMOSTAT 29
25. pa acqua Fig 26 Rif1 Agire sulla vite di regolazione Fig 26 Rif 2 e serrare i bulloni di fissaggio Fig 26 Rif1 N B per un corretto funzionamento della pom pa acqua eseguire queste operazioni ogni 200 ore 4 9 14 Water pump belt Testing method Press the belt with about 10Kg andbe sure that bending is not superior to 0 5 cm Fig 25 REMEDY Stretch the belt Slacken the fixing bolts of the water pump Fig 26 Ref 1 Adjust the screw Fig 26 Rif 2 and tighten the fixing bolts Fig 26 Rif1 N B For a correct functioning of the water pump repete these operations every 200 hours period 25 4 9 15 Pompa acqua Caratteristiche diametro 40mm altezza 20mm type Johnson F35 B 8 Metodo di controllo Visivo Togliere le viti Fig 27 Rif 1 e rimuovere il coperchio pompa Fig 27 Rif 2 Rimuovere la girante Fig 27 Rif 3 RIMEDIO Sostituire la girante N B Per un corretto funzionamento del gruppo e necessario eseguire questa verifica ogni 300 ore oppure dopo un anno 26 4 9 15 Water pump Characteristics diameter 40mm height 20mm type Johnson F35 B 8 Testing method Visual Remove the screws Fig 27 Ref1 and pump cover Fig 27 Ref 2 Remove the impeller Fig 27 Ref 3 REMEDY Remove the impeller N B For a correct functioning of the generator repete these operations every 300 hours period or after a year s time of use 4 9 16 Regolazione dei giri Caratteristiche
26. stenza fra i cavi verdi rientri nei valori indicati in tabella IN ALTERNATIVA Verificare che fra i cavi verdi la tensione alter nata rientri nei valori indicati in tabella Testing method Disconnect from the terminal board the wires coming from the stator marked by the letters P F P F Fig 4 Verify that the resistance values between the two pairs of wire terminals P F and P F are within the limits as reported in the table above N B The total resistance value for power wind ing 220 V 240 V is measured connecting F and P the resistance value measured between P and F is double of that indicated in the table above REMEDY Replace the stator 4 3 Battery charger winding stator Testing method Disconnect the wires coming from the regulator Fig 5 and verify that the resistance values between the green wires are within the limits indicated in the table above AS AN ALTERNATIVE Verify that the voltage between the GREEN wires is as reported above 11 N B Eseguire questa misura senza carichi applicati al generatore con batteria d avvia mento inserita e dopo averatteso qualche minu to dall avviamento RIMEDIO Sostituire lo statore IMPORTANTE Il circuito del carica batteria dotato di un regolatore elettronico di carica in grado di erogare max 15 A a 12 V in caso di anomalia nella ricarica della batteria dopo aver controll
27. teria 12V collegando il della batteria al della pompa ed il della batteria al della pompa Fig 20 ATTENZIONE Il raffreddamento della pompa viene garantito dal passaggio del gasolio Per evitare di RIMEDIO Sostituire la pompa N B Sul circuito del gasolio prima della pompa e installato un filtro del tipo a cartuccia Per un corretto funzionamento della pompa stessa prov vedere alla sostituzione della cartuccia ogni 300 h 22 4 9 9 Diesel pump Caracteristics 12V Testing method Disconnect the wires Connect a 12V battery pole to the of the pump and pole to the of the pump and verify if it s running well Fig 20 ATTENTION The pump is cooled directly by the passage of DIESEL Take care therefore thatthe pump doesn trun in dry condition without petrol REMEDY Replace the pump N B On the diesel circuit is installed a filter cartridge type before the pump For a correct functioning of the pump itself replace the cartridge every 300 hours 4 9 10 Termostato acqua Caratteristiche Contatto normalmente aperto Contatto chiuso T gt 70 C 3 C Metodo di controllo Verificare che non ci sia continuita fra il posi tivo e massa Fig 21 Immergere il termostato in acqua a 70 C e verificare che chiuda il contatto RIMEDIO Sostituire il termostato 4 9 11 Pressostato olio Caratteristiche Contatto normalmente CHIUSO Contatto normalmente APERTO P 1 ATM
28. tremit del fusi bile Fig 12 Rif 1 RIMEDIO Sostituire il fusibile N B With this test the capacitoris checked for short circuits interruptions If however the ca pacity is diminished resulting in a voltage drop under no load condition this test cannot diag nose the problem In this case we suggest that the capacitor be replaced after having checked for other possible faults REMEDY Replace the capacitor 4 9 Relayp c board Testing method Verify the continuity at its terminals Fig 12 Ref 1 REMEDY Replace the fuse 15 30 87 Contact normally OPEN 30 87b Contact normally CLOSED Metodo di controllo Disinserire il rel Verificare che fra i punti 85 86 vi sia continuit Fig 13 Verificare che eccitando la bobina 12 v ai morsetti 85 86 il contatto 30 87 CHIUDE mentre il contatto 30 87b APRE RIMEDIO Sostituire il rel 4 9 3 Diodi Caratteristiche 1A1000V Direzione normale 0 850 Ohm Direzione inversa Mancanza di cont Metodo di controllo Smontare i rel Scollegare i cavi dalla morsettiera Fig 14 Verificare che la resistenza fra le due estremit rientri nei valori indicati Verificare che invertendo i puntali del tester non ci sia pi continuit RIMEDIO Sostituire il diodo 16 Testing method Remove the relay Verify that there is continuity between 85 and 86 Fig 13 Verify that exciting the coil apply
29. ue poli senza spazzole single phase 2 poles brushless Potenza continua Continuous output 1700W 1900W 2700W 2900W 4000W 4800W Fattore di potenza Power factor 1 1 1 Classe isolamento Insulation class F F F Frequenza Hz Frequecy Hz 50 60 50 60 50 60 DIMENSIONI DIMENSION Lunghezza Lenght 509mm 660mm 720mm Larghezza Width 406mm 460mm 490mm Altezza Height 445mm 545mm 565mm Peso Weight 65Kg 78Kg 110Kg 1 2 IDENTIFICAZIONE DEL GENERATORE IDENTIFICATION OF GENSET Il numero di matricola del generatore e riportato su di un targhetta metallica rivettata sulla parte inferiore della cassa Fig A Qualora non sia possibile identificare il generatore da questo numero si faccia riferimento al numero di matricola del mo tore punzonato sul basamento Fig B Each generator has an identification number impressed on a small metallic plate and rivetted to the lower front side of the sound shield Fig A In case identifying by this number becomes impossible please note the engine number die stamped on the crankcase Fig B 1 3 IDENTIFICAZIONE DEI COMPONENTI IDENTIFICATION OF COMPONENTS Elementi della macchina Fig 5 1 MOTORE ALTERNATORE CRUSCOTTO ALTERNATORE ELETTROVALVOLA DI ARRESTO POMPA ACQUA RITORNO COMBUSTIBILE LEVA ARRESTO MANUALE ASTA LIVELLO OLIO POMPA COMBUSTIBILE INGRESSO COMBUSTIBILE INGRESSO TUBAZIONE ACQUA PRESA ARIA