Home

Manutenzione

image

Contents

1. Rivets Maintenance Maintenance Troubles causes solutions PROBLEMS The vacuum sockets do not function POSSIBLE CAUSE Power cable disconnected Input cable disconnected Filter cartridge soiled SOLUTIONS Connect the power cable Connect the input cable Renew the filter cartridge One vacuum socket does not function Poor suction With all vacuum sockets closed the power unit remains on Micro switch of a vacuum socket defective or hose switch defective Filter cartridge soiled Seal of the dust contniner damaged or not in position Use of more vacuum sockets at a time Air intable tube blocked Air infiltration in the power unit Air exhaust tube blocked Micro switch of a vacuum socket defective or hose switch defective Call a specialised technician Renew the filter cartridge Refit the seal or the rubber ring Use one vacuum socket at a time Call a specialised technician Call a specialised technician Call a specialised technician Call a specialised technician specialised technician Any other cause that isn t indicated in this manual requires the intervention of a 2O AIRBLU ASPIRAPOLVERE CENTRALIZZATO AIRBLU Aspirapolvere Centralizzato Central Vacuum System Via del Lavoro 21 A 47035 Gambettola FC ITALY Tel 39 0547 59308 Fax 39 0547 657683 info airblu com www airblu com E vietato un utilizzo della centrale aspirante diverso da quello descrit
2. bolla verificare il corretto allineamento del fissaggio a parete 2 Spostare la leva di bloccaggio Installazione Installazione 4 Montare gli antivibranti nel supporto 5 Fissare il supporto con i tasselli ad espansione 6 Smontare il contenitore polveri 8 Verificare il corretto aggancio della leva di bloccaggio 8 9 Collegamento tubazioni Griglia di sfiato Tubazione di scarico Tubazione di aspirazione AUR0300 Collegamento elettrico L impianto elettrico di alimentazione della centrale di aspirazione deve essere realizzato da personale qualificato e in conformit alle norme vigenti in materia Il costruttore declina ogni responsabilit per il cattivo funzionamento o per danni a persone e o cose derivanti dal collegamento ad un impianto elettrico non conforme Verifica finale Dopo aver effettuato tutti i collegamenti elettrici dell impianto verificare singolarmente ogni presa di aspirazione utilizzando il tubo flessibile 3 Incollare il silenziatore sul tubo di scarico nelle _ vicinanze della griglia N disfiato 1 Collegare il manicotto alla tubazione di scarico aria 2 Montare il manicotto con le due fascette e collegarlo alla tubazione di aspirazione AUR0350 Pericolo Non toccare la centrale con le mani bagnate o umide Non lasciare che i bambini o persone non autorizzate si avvicinino o utilizzino la centrale Al
3. by AIRBLU The warranty terms and conditions are those envisaged by the current European legislation In any case the warranty does not cover e failures defects or damage due to a wrong connection to the mains during or after installation e failures defects or damage due a malfunctioning of parts of the systems e g vacuum sockets if these parts are not directly manufactured by AIRBLU e failures defects or damage due to a clogging of the piping e failures defects or damage due neglect abuse or misuse e materials parts and accessories including electrical and electronic components if such defects are not arising from faulty workmanship or are attributable to normal wear and tear The warranty shall cease to have effect in case of modifications or repair works carried out by non authorised persons or using non genuine spare parts Any other obligations of the manufacturer are expressly excluded and will be at the sole charge of those who undertake them Jurisdiction and venue will be exclusive to the Court of Forli Cesena ITALY The terms and conditions herein shall be governed by and construed in accordance with Italian law Warranty terms and condition for non EC countries For the countries which are not EC members the warranties will be provided by the importer and will be in accordance with the laws and regulations in force in the country of export of the product General information General
4. cablaggio Nylon 6 6 etichetta resinata AIRBLU PVC etichetta anomalie PVC Le norme che regolano lo etichetta pericolo 230v PVC sualtinento la demolizione della centrale silenziatore Polistirolo dei suoi componenti e delle spugna vano motore Poliuretano espanso sostanze inquinanti liat isi NVI saone eventualmente presenti tae iatore espulsione y a caricato vetro LEO EEEE aa paese di utilizzo finale sacco raccolta polveri PVC Si raccomanda di rivolgersi Elementi agli organismi ed enti z ti elementi di assemblaggio Viteria varia preposti in materia e di Ane rispettare le norme di legge Avvolgimenti motore elettrico vigenti in materia in rame cablaggi scheda elettronica G _ motore turbina omponenti m elettrici fili elettrici cavo plug spina schuko corpo superiore molle Componenti cuffia motore metallici cerniere spina schuko rivetti Manutenzione Manutenzione INCONVENIENTI L aspirazione d aria assente da tutte le prese Inconvenienti cause rimedi CAUSA EVENTUALE Cavo di alimentazione scollegato Cavo di attivazione scollegato Cartuccia filtrante intasata RIMEDI Collegare il cavo di alimentazione Collegare il cavo di attivazione Procedere alla sostituzione della cartuccia filtrante L aspirazione d aria assente da una sola presa Microinterruttore di una presa di aspirazione guasto o interruttore sul tubo di aspirazione guasto Contattare un tecnico specializzat
5. the power unit has been connected to the mains check all vacuum sockets using the flexible hose 1 Connect the power cable Power supply Fuse Led power ON b R AUR0350 Power outlet Led power unit running Input signal outlet Signal input 2 Connect the signal input cable vacuum sockets circuit AUR0330 Installation Maintenance Maintenance A di Before any maintenance job turn off the power unit A thorough maintenance increases the lifespan of the power unit and grants better performances Do not operate the power unit without a filter cartridge Not observing this precaution may result in serious damage to the turbine and will void the manufacturer s warranty Emptying the dust container Before this job wear your personal protective equipment 1 Remove the dust container 2 Lift out the conveying ring 3 Empty the dust container AUR0490 4 Reassemble the dust container paying attention to the seal position AUR0580 24 2 5 Cleaning the filter cartridge Before this job wear your personal protective equipment Remark If the central vacuum system is used regularly check the filter cartridge at least every 4 months Remove the filter cartridge and wash it with tap water During washing pay attention not to damage the filtering cloth If during cleaning the cloth gets damaged the cartridge must be rene
6. 20rsssrs sese zi ze nani nineo Troubles causes solutions 1 5 General warnings Use of the manual The instruction manual for use and maintenance is an integral and essential part of the vacuum power unit and must be handed over to the user It must be kept in a safe place and consulted carefully as all of the warnings provide important instructions for safety in the phases of installation use and maintenance Responsibility The vacuum power unit must be used only for the purpose for which it has been designed Any other use is considered improper use and is therefore dangerous The manufacturer accepts no contractual or extra contractual liability for damage arising from a wrong installation or operation or from the non compliance with the manufacturer s instructions Remark AIRBLU reserves the right to effect changes to the product and the relevant technical literature without incurring in any obligation No part of this manual can be reproduced copied or transmitted to third parties in any form or by any means without prior written authorisation from AIRBLU This manual is printed entirely on recycled paper Warranty Warranty terms and condition for EC countries AIRBLU warrants the proper functioning of its products for a period of 24 months from the date of purchase In the absence of documents proving the date of purchase invoice or cash slip the warranty period will start from the date of sale
7. 270 Superfice filtrante m 0 4 Materiale cartuccia filtro poliestere Capacit contenitore polveri 15 Altezza cm 58 Diametro cm 28 Peso kg 13 Contenitore plastica Cupola plastica Quota A cm 28 5 A Valori misurati con alimentazione a 230 V frequenza 50Hz ioni genera EC120 EC150 EC250 EC350 220 240 220 240 220 240 220 240 1260 1280 1430 1600 43 507 24 560 23 200 25 760 1 2 3 3 12 12 12 12 207 190 170 ins a 270 a 250 a 307 A 337 0 8 0 8 0 8 0 8 poliestere poliestere poliestere poliestere 15 23 23 23 90 103 103 103 28 32 32 32 16 18 18 18 plastica plastica plastica plastica plastica plastica plastica plastica 92 5 37 37 37 n Centrale aspirante con convogliatore montato per espulsione aria EC150 EC250 EC350 a_i Informaz 5 Funzionamento Uso previsto La centrale di aspirazione EC stata progettata e costruita per essere installata in impianti aspirapolvere centralizzati di edifici civili La centrale collegata alla rete tubiera che si dirama nei vari locali Alle estremita delle tubazioni vengono installate le prese di aspirazione alle quali si collegano gli accessori per la pulizia La centrale stata progettata per aspirare esclusivamente polvere o corpi solidi di minuscole dimensioni Non deve essere usata per aspirare m
8. 4 polyester 15 58 28 13 plastic plastic 28 5 a Values measured with 230 V 50Hz EC120 EC150 V 220 240 220 240 1260 1280 43 507 24 560 1 2 12 12 207 190 a 2 0 A 250 0 8 0 8 polyester polyester 15 23 90 103 28 32 16 18 plastic plastic plastic plastic 32 5 37 220 240 220 240 EC250 EC350 220 240 1430 1600 23 200 25 760 3 3 12 12 170 175 A 307 4 337 0 8 0 8 polyester polyester 23 23 103 103 32 32 18 18 plastic plastic plastic plastic 37 37 Vacuum unit with expulsion conveyor EC150 EC250 EC350 18 1 9 Operation Envisaged use The EC power unit has been designed to power central vacuum systems for residential buildings The power unit is connected to the tubing serving the various rooms Special inlets are installed atthe ends of these tubes for plugging the various cleaning accessories The vacuum unit has been designed to remove dust and small solid matters and must not be used to remove burning or damp materials fabrics etc since they can damage it or obstruct the tubes Wear personal protective equipment when emipying the dust container or cleaning changing the filter Improper use To avoid risks to people and a wrong functioning of the power unit take the fh following measures Don t vacu
9. Manuale uso e manutenzione Use and maintenance manual CE Centrale aspirante Central power unit EC 80 EC 120 EC 150 EC 250 EC 350 Manuale uso e manutenzione ITALIANO Indice Generale Avvertenze generali 0sssssseeseeee 1 Garanzia 2 s2r crrs creare sane nese iie nni 1 Sicurezza 21 2sv20rs rss aree senesi ne nni 2 Identificazione 2 Descrizione delle parti 1 s1 201s 3 Caratteristiche tecniche 1 4 Funzionamento Avviamento Spegnimento 5 Movimentazione e disimballo 6 Installazione centrale 1 2 210200001 7 Collegamento tubazioni 9 Collegamento elettrico 2s 210 9 Manutenzione sr 2 sr ersscrea inizino 10 Svuotamento contenitore polveri 10 Rigenerazione cartuccia filtrante 11 Manutenzione cartuccia filtrante 12 Smaltimento ccsseeseeeeeeeeeeeeeeeeeeeee Inconvenienti cause rimedi Avvertenze generali Utilizzo del manuale Il manuale d installazione d uso e manutenzione costituisce parte integrante ed essenziale della centrale aspirante e deve essere consegnato all utilizzatore Va conservato con cura e consultato attentamente in quanto contiene indicazioni importanti per la sicurezza degli operatori per il funzionamento e per una corretta manutenzione Responsabilit La centrale deve essere destinata solo all uso per la quale stata e
10. a model with outside exhaust ensure the room is properly ventilated The power unit must be fixed to the wall at a height that allows for an easy dismantling of the dust container and the replacement of the filter cartridge AUR0470 How to install the power unit You can fix the power unit with M6 012 screw anchors 1 Drill Using a water level check that the fixing is level with the wall 2 Shift the locking lever Installation Installation 4 Fit the vibration blocks to the support 5 Fix the support with screw anchors 6 Remove the dust container AUR0270 8 Make sure the locking lever locks in position AUR0280 22 23 Connecting the tubes Air vent Air exhaust tube 1 Fit the sleeve to the air exhaust tube 3 Glue the silencer to the air exhaust tube close to the air vent An take 2 Fit the sleeve to the air intake tube and connect with two fasteners AUR0300 Engish Electrical connection The electrical installation of the power unit Danger must be done by qualified electrical installers Do not touch the power unit with according to the regulations in force wet or damp hands The Manufacturer accepts no liability for a Keep children and non authorised wrong functioning of the power unit or people clear of the power unit damage to persons or property attributable to a wrong electrical connection Final check Once
11. ateriale rovente tessuti materiali umidi ecc che possano occludere le tubazioni o danneggiare la centrale Utilizzare indumenti di protezione Q individuale prima di eseguire le operazioni di scarico delle polveri e la sostituzione pulizia della cartuccia filtrante Uso improprio Al fine di evitare rischi per le persone ed un cattivo funzionamento della centrale rispettare le seguenti A indicazioni Non aspirare tessuti o materiale pesante o umido Non aspirare materiale incandescente Non aspirare liquidi Questo tipo di aspirazione si pu effettuare solo con l uso di un apposito accessorio Non permettere ai bambini di giocare con le prese di aspirazione Non utilizzare contemporaneamente pi prese aspiranti Non utilizzare la centrale in assenza di cartuccia filtrante Non ostruire le tubazioni di scarico dell aria Non ostruire le prese d aria per il raffreddamento del motore elettrico Scollegare i cavi di alimentazione prima di eseguire qualsiasi intervento di manutenzione Non mettere a contatto con parti del corpo gli accessori per l aspirazione Utilizzare gli indumenti di protezione individuale mascherina e guanti prima di eseguire lo scarico della polvere sostituzione pulitura filtro In caso di incendio non utilizzare acqua per spegnerlo Non lasciare in funzione inavvertitamente la centrale quando non si usa Non lasciare la centrale collegata all alim
12. della cartuccia filtrante almeno una volta ogni 4 mesi Estrarre la cartuccia filtrante da rigenerare e procedere alla pulizia tramite un getto d acqua non troppo forte facendo attenzione a non lacerare il tessuto filtrante Se durante l operazione di pulizia del filtro si dovesse lacerare la cartuccia sostituirla con una nuova Dopo ogni lavaggio la cartuccia filtrante deve essere assolutamente asciugata senza essere esposta a forti fonti di calore Si consiglia di avere una cartuccia filtrante di ricambio originale AIRBLU da utilizzare nel periodo di rigenerazione Nota bene La centrale aspirante non deve essere messa in funzione senza la cartuccia filtrante inserita al suo interno L inosservanza di questa regola potrebbe anor baa causa di danni alla turbina 4 Verificare che non siano presenti aspirazione lacerazioni altrimenti sostituire A Utilizzare esclusivamente ricambi originali AIRBLU 1 Aspirare la polvere raccolta sulle pareti della cartuccia AUR0380 AUR1020 Manutenzione Manutenzione Manutenzione cartuccia filtrante Sostituzione cartuccia filtrante Si consiglia di sostituire la cartuccia filtrante ogni 2 3 anni questo dato pu variare a seconda del grado di utilizzo dell impianto Prima di procedere a qualsiasi operazione di manutenzione togliere tensione alla centrale aspirante Prima di procedere si raccomanda O di utilizzare indumenti di protezione indivi
13. di messa terra a norma Togliere completamente tensione alla centrale aspirante per operazioni di manutenzione PERICOLO DI SCHIACCIAMENTO si raccomanda in fase di spostamento e installazione della centrale aspirante di utilizzare mezzi idonei per il sollevamento e di effettuare il fissaggio come descritto onde evitare la caduta accidentale della centrale PERICOLO DANNI ALLA CENTRALE rispettare le indicazioni d uso riportate in maniera da non incorrere in delle conseguenze che potrebbero portare al danneggiamento della centrale INALAZIONE DI ELEMENTI NOCIVI E POLVERI proteggere gli organi di respirazione mediante l utilizzo di maschere protettive durante lo svuotamento del contenitore polveri e nella sostituzione della cartuccia filtrante per evitare di respirare le polveri raccolte SENSIBILITA ALLE POLVERI indica che bisogna utilizzare una protezione per le mani onde evitare danni ad operatori sensibili all azione delle polveri raccolte A Identificazione Questo manuale di uso e manutenzione inerente alla centrale SERIE EC MODELLO EC80 EC120 EC150 EC250 EC350 COSTRUTTORE AIRBLU Via del lavoro 21 A 47035 Gambettola FC ITALY Tel 39 0547 59308 Fax 39 0547 657683 www airblu com Assistenza tecnica Il Centro di Assistenza AIRBLU a disposizione per qualunque problema tecnico e per la richiesta di parti di ricambio Per qualsiasi comunicazione relativa alla centra
14. duale 1 Smontare il contenitore polveri AUR0260 2 Svitare il dado e sostituire la cartuccia filtrante sporca AUR0390 3 Serrare il dado ruotando la cartuccia filtrante assicurandosi che appoggi in modo corretto AURO580 Nota bene La centrale aspirante non deve essere messa in funzione senza la cartuccia filtrante inserita al suo interno L inosservanza di questa regola potrebbe essere causa di danni al motore della centrale Utilizzare esclusivamente ricambi originali AIRBLU 12 1 3 Smaltimento Alla conclusione del suo ciclo di vita la macchina deve essere smaltita secondo le norme vigenti in materia db La tabella che segue riporta i materiali con P I sottoelencati materiali vanno suddivisi ed immagazzinati per essere eventualmente recuperati o cui sono realizzate le centrali TIPO DI PRESENZA smaltiti nel rispetto delle norme ambientali vigenti nel paese di utilizzazione SPECIFICA SMALTIMENTO MATERIALE NELLA CENTRALE Lamiera corpo principale Acciaio verniciato cono in gomma Epdm vulcanizzato bocchettone tangenziale Polipropilene cupola e contenitore polveri Polipropilene guarnizione sottomotore Gomma termoplastica cartuccia filtrante Poliestere cruscotto portascheda Lexan kamo staffa fissaggio Nylon caricato A antivibranti staffa Gomma Plastiche sr e manicotti Gomma SBR NR Gomme fascette
15. eful working life the machine must be disposed of according to the relevant regulations in force The following table shows the materials used in the power units db The materials listed below must be separated and stored to be qP recycled or disposed of in the respect of the environmental regulations in force in the country the machine is used in TYPE OF MATERIAL Mote7 W ale SPECIFICATIONS DISPOSAL Painted steel sheet Mainibody Conveying ring Rubber Fittings Polypropylene Dome and container Polypropylene Motor packing Rubber Filter cartridge Polyester Dashboard Lexan Wall stirrup 50 reinf nylon Plastic and Stirrup vibration blocks Rubber Engish rubber Rubber sleeves SBR NR rubber materials Fasteners Nylon 6 6 Licks eh CE APE cee PAS and demolition of the Anomalous decal PVC machine its 230v danger decal PVC components and any Silencer Polystyrol pollutants present vary Sound proofing sponge Polyurethane depending on the final Convolving air 50 reinf nylon country of use Dusty bag PVC We recommend Galvanised contacting the parts Fixing assembling elements authorised companies Copper Electric motor ang podies ang windings Wiring harness respecting any regulations in force Electrical cable A Turbine motor il EI Electrical cable Plug cable Schuko connector Superior body Springs Metal Motor cap components Hinges Fasteners
16. entazione elettrica nel caso in cui sia previsto un lungo periodo di non attivit Avviamento Spegnimento Inserire il tubo flessibile nell apposito ingresso A Il tubo flessibile pu essere di due tipi 1 tubo flessibile con raccordo ad anello attivatore B 2 tubo flessibile con interruttore C Con il tubo flessibile di tipo 1 la centrale si avvia inserendo il tubo nell ingresso A Con il tubo flessibile di tipo 2 la centrale si avvia premendo l apposito interruttore posto sul tubo stesso Inserire il raccordo tubo presa con le apposite piastrine D in corrispondenza dei contatti E nella presa Per lo spegnimento della centrale con il tubo flessibile di tipo 1 estrarre il tubo dall ingresso A con il tubo flessibile di tipo 2 portare l interruttore posto sul tubo stesso in posizione OFF Funzionamento Trasporto Movimentazione e disimballo La centrale aspirante viene consegnata dentro un imballo di cartone per facilitarne il trasporto Si raccomanda di non togliere l imballaggio fino al momento della messa in funzione per evitare urti o danneggiamenti A Usare mezzi idonei per la corretta movimentazione Per il disimballo della centrale aspirante seguire le indicazioni riportate sull imballo Controllare che il prodotto non sia danneggiato e che all interno del contenitore polveri ci sia tutta la dotazione di serie come da foglio allegato all imballo In caso cont
17. es Service is at your complete disposal to provide you technical assistance or spare parts If you need to contact the manufacturer in relation to your vacuum power unit please supply the following data a model of the power unit b serial number c year of manufacture d date of purchase e detailed description of the problems Remark Use only genuine spare parts AIRBLU accepts no liability for damage to the vacuumpower unit resulting from the use of non genuine spare parts Data plate The data plate of these models is installed on the top of the power unit The plate indicates the unit model serial number year of manufacture as well as the main technical data Data plate AUR0410 16 1 T Description of the parts AUR0420 Legend 1 Fuse 2 Power input 3 Operation signal input 4 Sound proof motor compartment 5 Air exhaust line 6 Wall stirrup 7 Air intake line 8 Dust container hinges 9 Filter cartridge 10 Dust conveying ring 11 Dust container General information General information Technical characteristics Characteristics Voltage Motor power Motor revolutions Turbine stages Vacuum socket voltage Air flow Max vacuum Filtering surface Filter cartridge material Dust container capacity Height Diameter Weight Container Dome Height A WwW rpm n Vv m h mbar m2 cm cm kg cm EC80 1260 43 507 1 12 207 a 2 0 0
18. imentazione 1 Collegare il cavo di alimentazione elettrica Led centrale in funzione Ingresso segnale attivazione Presa di alimentazione Presa segnale di attivazione circuito prese aspiranti 2 Collegare il cavo di attivazione AUR0330 Installazione Manutenzione Manutenzione 10 Prima di procedere a qualsiasi 2 Togliere il cono convogliatore A operazione di manutenzione togliere tensione alla centrale aspirante Una manutenzione accurata prolunga la durata della centrale aspirante e assicura migliori prestazioni La centrale aspirante non deve essere messa in funzione senza la cartuccia filtrante inserita al suo interno L inosservanza di questa precauzione potrebbe essere causa di danni alla turbina e del conseguente annullamento della garanzia ee 3 Svuotare il contenitore polveri Svuotamento contenitore polveri i Prima di procedere si raccomanda di utilizzare indumenti di protezione individuale 1 Smontare il contenitore polveri 4 Montare il contenitore di raccolta polveri facendo attenzione alla guarnizione di tenuta AUR0580 1 1 Rigenerazione cartuccia filtrante 2 Lavare la cartuccia filtrante sotto il Q Prima di procedere si raccomanda lavandino con un getto d acqua non troppo di utilizzare indumenti di forte protezione individuale Nota bene Si consiglia utilizzando il sistema centralizzato con normale frequenza un controllo
19. information Safety The following safety notices are used to highlight all those situations to which the operator must pay great attention to prevent personal injury or damage to the vacuum power unit DANGER indicates a hazardous situation which if not avoided will result in serious injury DANGERS OF ELECTRICAL NATURE Make sure the power unit is connected to a type approved ground system with efficient plates Turn off the power unit before any maintenance job A RISK FO CRUSHING While handling and installing the power unit use suitable lifting means and fix the unit as per instructions so as to prevent an accidental fall DANGER RISK OF DAMAGE TO THE POWER UNIT Observe the instructions to avoid possible damage to the vacuum power unit INHALATION OF HARMFUL SUBSTANCES AND DUST Protect the respiratory organs with a mask when emptying the dust bag or replacing the filter to prevent sensitization to dust 9 gt SENSITIZATION TO DUST operators should compulsorily protect their hands so as to prevent allergic reactions in case of contact with the collected dust Identification This instruction manual for use and maintenance is for the following vacuum power units SERIES EC MODEL EC80 EC120 EC150 EC250 EC350 MANUFACTURER AIRBLU Via del lavoro 21 A 47035 Gambettola FC ITALY Tel 39 0547 59308 Fax 39 0547 657683 www airblu com Technical service AIRBLU After Sal
20. le aspirante si raccomanda all utilizzatore di fornire sempre i seguenti dati a modello della centrale aspirante b numero di matricola c anno di fabbricazione d data di acquisto e indicazioni dettagliate sui problemi riscontrati Nota bene Per la sostituzione delle parti di ricambio della centrale aspirante si raccomanda l utilizzo di ricambi originali AIRBLU declina ogni responsabilit riguardo eventuali peggioramenti delle prestazioni o per danni alla centrale dovuti all uso di pezzi di ricambio non originali Targa di identificazione La targa di identificazione di questi modelli situata sulla parte superiore della centrale aspirante Essa contiene il modello il numero di matricola l anno di fabbricazione e i dati tecnici della centrale stessa Targa di identificazione AUR0410 2 3 Descrizione delle parti AUR0420 Legenda 1 Fusibile 2 Ingresso alimentazione elettrica 3 Ingresso segnale di attivazione 4 Vano motore insonorizzato 5 Linea espulsione aria 6 Staffa di fissaggio 7 Linea di aspirazione 8 Cerniere contenitore polveri 9 Cartuccia filtrante 10 Cono convogliatore 11 Contenitore polveri ioni genera Informaz Caratteristiche tecniche Caratteristiche 307 0 Alimentazione V 220 240 Potenza motore Ww 1260 Giri motore rom 43 507 Stadi turbina n 1 Alimentazione prese vV 12 Portata aria m h 207 Depressione max mbar a
21. negligenza incapacit o uso improprio e Materiali componenti e accessori compresi quelli elettrici ed elettronici qualora non si tratti di difetti originari di costruzione e quando il danneggiamento dovuto a usura del componente La garanzia decade nel caso di manomissioni di riparazioni effettuate da persone non autorizzate o eseguite con ricambi non originali Altre eventuali condizioni di garanzia aggiuntive saranno solo ed esclusivamente a carico di chi le propone Per qualsiasi controversia competente esclusivamente il foro di Forl Cesena e si applicher la legislazione italiana Condizioni di garanzia EXTRA CEE Per i paesi non facenti parte della CEE la garanzia sar a carico della societ importatrice e le condizioni di garanzia saranno quelle previste dalla normativa vigente nel paese dove il prodotto sar esportato ioni genera Informaz ioni genera Informaz Sicurezza La presente segnaletica viene utilizzata all interno del manuale per evidenziare tutte quelle operazioni che devono essere osservate scrupolosamente dall operatore per garantire la sicurezza della centrale aspirante e delle persone PERICOLO indica che bisogna A prestare attenzione in maniera da non incorrere in eventi che potrebbero provocare incidenti gravi alle persone o danni alla salute PERICOLI DI NATURA ELETTRICA accertarsi che la centrale aspirante sia collegata mediante il relativo cavo ad un impianto
22. o L aspirazione scarsa Cartuccia filtrante intasata Guarnizione del contenitore di raccolta danneggiata o fuori posto Utilizzo contemporaneo di pi prese Otturazione della tubazione di aspirazione Infiltrazione d aria nella centrale Scarico d aria bloccato Sostituire la cartuccia filtrante Sistemare la guarnizione o il cono in gomma Utilizzare una sola presa aspirante alla volta Contattare un tecnico specializzato Contattare un tecnico specializzato Contattare un tecnico specializzato La centrale sempre attivata anche con le prese chiuse Microinterruttore di una presa di aspirazione guasto o interruttore sul tubo di aspirazione guasto Contattare un tecnico specializzato specializzato Altre cause non riportate in questo manuale richiedono la chiamata di un tecnico 14 Use and maintenance manual ENGLISH Contents General warning Warranty gt Description of the parts x x 17 Technical characteristics 18 Operation 21 1xxrrssrsrsseeieeia nine nina Starting Stopping 11 srs0rsserena Handling and unpacking Installing the power unit Connecting the tubes 1 10x1 Electrical connection Maintenance ccssseeeeeeeeeeseeeneeenees Emptying the dust container 24 Cleaning the filter cartridge 25 Maintaining the filter cartridge 26 Disposal 10 21r
23. rario contattare immediatamente il Centro Assistenza AIRBLU AURO170 Attenzione L imballaggio della centrale aspirante deve essere mantenuto nella posizione indicata dalle avvertenze presenti sull involucro esterno per evitare il capovolgimento e l uscita dei componenti interni della centrale AIRBLU declina ogni responsabilit per eventuali danni a persone o cose derivanti da una errata apertura dell imballaggio Nota bene Gli elementi dell imballaggio che accompagnano la centrale alla consegna costituiscono rifiuti solidi inerti che devono essere smaltiti secondo le norme vigenti in materia AUR0460 T Installazione centrale Posizionamento La centrale deve essere installata in locali di servizio es ripostiglio o garages che siano protetti dalle intemperie umidit o sbalzi di temperatura L ambiente di installazione deve essere sufficientemente spazioso e illuminato da garantire agevolmente qualsiasi intervento sulla centrale Per l installazione dei modelli con lo scarico dell aria in ambiente necessario che sia garantita un areazione adeguata La centrale deve essere fissata alla parete ad un altezza che consenta di eseguire comodamente lo svuotamento del contenitore polvere e la sostituzione della cartuccia AUR0470 Modalit di installazione Il fissaggio viene eseguito con tasselli ad espansione M6 012 1 Eseguire i fori come indicato Mediante l uso della
24. spressamente prevista ogni altro uso da considerarsi improprio e quindi pericoloso E esclusa qualsiasi responsabilit contrattuale ed extra contrattuale del costruttore per i danni causati da errori nell uso e nell installazione della centrale o comunque da inosservanza delle istruzioni date dal costruttore stesso Nota bene AIRBLU si riserva il diritto di modificare il prodotto e la relativa documentazione tecnica senza incorrere in alcun obbligo nei confronti di terzi Nessuna parte di questo manuale pu essere riprodotta copiata o divulgata con qualsiasi mezzo senza l autorizzazione scritta di AIRBLU Garanzia Condizioni di garanzia per paesi CEE AIRBLU garantisce il buon funzionamento dei propri prodotti per il periodo di 24 mesi a partire dalla data di installazione In caso di assenza della data di installazione il periodo di 24 mesi sar riferito alla data di vendita da parte di AIRBLU Le condizioni di garanzia sono quelle previste dalla vigente legislazione europea ed in ogni caso non sono compresi nella garanzia e Guasti danni o rotture provocati da errato allacciamento elettrico durante o dopo l installazione e Guasti danni o rotture provocati da malfunzionamenti di altri componenti dell impianto es prese aspiranti qualora questi componenti non siano AIRBLU e Guasti danni o rotture provocati da otturazione della tubazione e Guasti danni o rotture provocati da trascuratezza
25. th the type 2 flexible hose turn the switch on the hose OFF tructions ing ins Operat Transport Handling and unpacking The power unit is delivered in a carton box to make its transport easier Do not remove the unit from the packaging until installation to prevent accidental crashes or damage A Use suitable handling equipment Remove the power unit from the box according to the instructions provided Check that the product is not damaged and all the standard parts are contained in the dust container see sheet enclosed In case of damage or missing parts call in the AIRBLU After Sales Service AURO170 20 Warning Keep the box in the position indicated in the instructions outside the box itself to avoid overturning and possible fall of internal components of the power unit AIRBLU accepts no liability for damage to the power unit arising from a wrong unpacking Remark The packaging elements in which the power unit is contained are inert solid wastes that must be disposed of in accordance with any local and national regulations AUR0460 21 Installing the power unit Positioning The power unit shall be installed in service rooms such as a store room or a garage and protected against weather agents humidity and sudden changes of temperature The installation place shall be sufficiently spacious and well lit to allow for an easy intervention on the vacuum unit When installing
26. to in questo manuale Le descrizioni e le illustrazioni tecniche possono variare AIRBLU si riserva il diritto di apportare modifiche al prodotto e alla relativa documentazione tecnica senza incorrere in alcun obbligo nei confronti di terzi La presente stesura del manuale di istruzioni per l uso e la manutenzione descrive le caratteristiche relative alla centrale aspirante in produzione di serie alla data in cui questa pubblicazione viene licenziata per la stampa Any use of the machine other than that stated in this manual is expressly forbidden Technical descriptions and pictures may be subject to variations The manufacturer reserves the right to effect changes to the product and the relevant technical literature without incurring in any obligation This operation and maintenance manual describes the characteristics of the standard machine at the time of printing COD 8001109 REV 1 09
27. um fabrics or heavy and damp material Don t vacuum burning materials Don t vacuum fluids This operation can only be done with the special accessory part Keep children clear of the vacuum sockets Use only a vacuum socket at a time Do not use the vacuum unit without filtering cartridge Do not block the air exhaust tubing Don t block the electric motor cooling inlets Before any maintenance jobs turn the power off Avoid any contact of the cleaning accessories with parts of the body Wear protective clothes and your personal protective equipment mask and gloves before emptying the dust container or renewing cleaning the filter Do not use water to put out a fire Turn off the power unit when the system is not used Disconnect the vacuum unit from the mains in case of a prolonged inactivity Starting Stopping Insert the flexible hose into the relevant inlet A Two types of flexible hoses are available 1 with connector with metal start up ring B 2 with switch C With the type 1 flexible hose the power unit starts when the hose is inserted in inlet A With the type 2 flexible hose the power unit starts when the relevant switch on the hose is pressed Insert the hose socket connection with the relevant plates D corresponding with contacts E in the socket To turn the power unit off with the type 1 flexible hose pull the hose out of inlet A wi
28. wed After washing allow the cartridge to dry Do not expose it to strong heat sources Keep an AIRBLU spare cartridge within reach to fit it to the power unit while cleaning the soiled cartridge Remark Do not operate the power unit without a filter cartridge Not observing this precaution may result in serious damage to the turbine Use only AIRBLU genuine spare parts 1 Remove the dirt from the cartridge walls AUR1020 2 Wash the cartridge with tap water paying attention not to damage its cloth 3 Allow the cartridge to dry AUR0370 4 Check for damage and replace the cartridge if necessary AUR0380 Maintenance Maintenance Maintaining the filter cartridge Before this operation turn off the power unit Renewing the filter cartridge Renew the filter cartridge every 2 3 years This time can change depending on the use of the central vacuum system Before this job wear your personal O protective equipment 1 Remove the dust container AURO260 2 Loosen the nut and replace the soiled cartridge AUR0390 3 Tighten the nut by screwing the new cartridge until it rests correctly 4 Mount the dust container AURO580 Remark Do not operate the power unit without a filter cartridge Not observing this precaution may result in serious damage to the turbine Use only AIRBLU genuine spare parts 20 D Disposal At the end of its us

Download Pdf Manuals

image

Related Search

Manutenzione manutenzione manutenzione in inglese manutenzione predittiva manutenzione ordinaria manutenzione sinonimo manutenzione caldaia manutenzione straordinaria manutenzione pc manutenzione tetto manutenzione preventiva manutenzione estintori manutenzione stampante epson manutenzione correttiva manutenzione programmata manutenzione stampante hp manutenzione ordinaria iva al 10% manutenzione ordinaria e straordinaria manutenzione straordinaria iva 10% manutenzione straordinaria detrazione 50% manutenzione ordinaria detrazione 50% manutenzione del possesso manutenzione mepa manutenzione velux manutenzione e assistenza tecnica manutenzione straordinaria in inglese

Related Contents

Vorago Volt FM2 A68K-8-1    Manuel d`utilisation  NC-501V(W) NC-500X(B) NC  Lexmark 312 Printer User Manual  É - Doodingues  Samsung ML-2251NP Инструкция по использованию    Samsung HT-C5200 Užívateľská príručka  

Copyright © All rights reserved.
Failed to retrieve file