Home

GB/GU-X18JR/X24JR/X36JR Operation

image

Contents

1. The set temperature must be lower than the room temperature If the set temperature is higher than the room temperature the unit will not produce cooling effect but will only operate under Fan mode DRY mode Fan motor will run at low fan speed in a specific temperature range The dehumidifying effect of this mode is better than that of the COOL mode and saves more energy HEAT mode The set temperature must be higher than the room temperature If the set temperature is lower than the room temperature the heating function will not be started AUTO mode The unit will adjust its operating mode automatically according to the ambient temperature SLEEP AUTO COOL DRY FAN HEAT men O ON OFF In heating operation the outdoor temperature is low and the humidity is high frost will produce on the outdoor unit The heating efficiency will be decreased When frosting occurs the unit will automatically start to defrost and DEFROST will be displayed GREE_duct_eng_1022 indd 5 T 08 10 27 3 32 05 OT TT p Bo 11 Im WIRE CONTROLLER OPERATION I Timer setting e When the unit is not operating timer start can be set CTT When the unit is operating timer shutoff can be set TE Sken The range of timer setting is between 0 5 to 24 hours HR 1 Press the TIMER button to enter the timer set status The word TIMER will flash on the display 2 P
2. re ju control wire Ip SUE IN F Wire clamp _ NS NN Control wire gt Cable cross loop Communication wire WY Da LA f 177 LiF metallic pipe metallicpipe UY a k f A 4 N 17 a A vi A ddl iif 4 199 IA 44 gar 4 4 7 7 F 4 o Yj y e 1 23 4 Gg 7 Figure 1 Figure 2 Schematic diagram of installation Surface mounting of Concealed mounting of cable cable No Name 1 Wall surface 2 Bottom plate of wire controller 3 Screw M4X10 4 Panel of wire controller Caution The communication distance between the main board and the wire controller is 8 meters The wire controller shall not be installed in a place where there is water drop or large amount of water vapor E 21 GREE_duct_eng_1022 indd 21 T 08 10 27 i GREE_duct_eng_1022 indd 22 T 08 10 27 ui INSTRUCTIONS OF UNIT INSTALLATION Electrical installation Caution Before installing the electrical equipment take care on the following matters e Check if the power supply is identical to the ratings on the nameplate The capacity of the power supply must be large enough The cable must be installed by professional personnel e Fit a disconnect switch having a contact separation of at least 3mm in all poles to the electricity power line Use a cable which is not lighter than polychloroprene sheathed flexible cord code designation 60245 IEC 57 Connection of single wire 1 Use wire s
3. Aten o Preste aten o ao seguinte quando limpar a unidade de ar condicionado Corte a alimenta o antes de entrar em contacto com o equipamento de liga o da linha Limpe a unidade de ar condicionado apenas quando esta estiver desligada e sem alimenta o Caso contr rio pode sofrer um choque el ctrico ou les es N o use gua para limpar o ar condicionado Se o fizer pode sofrer um choque el ctrico Use um escadote seguro Manuten o no in cio da esta o de funcionamento Se houver qualquer condi o anormal pe a informa es ao servi o p s venda Verifique a entrada e sa da do ar das unidades no interior e exterior para confirmar que n o existe qualquer bloqueio Verifique se o fio de liga o terra se encontra em boas condi es esta opera o tem de ser efectuada por um profissional Verifique se a liga o da linha se encontra em boas condi es esta opera o tem de ser efectua da por um profissional e Verifique se existe alguma palavra apresentada no LCD do controlador do fio ap s ligar a unidade alimenta o SINONLYOd Manuten o no final da esta o de funcionamento Quando o tempo estiver bom utilize a unidade no modo de ventoinha durante meio dia de modo a secar o interior da unidade Quando o ar condicionado n o for usado durante um longo per odo de tempo desligue a alimenta o As palavras no LCD do controlador do fio desaparecem Indi
4. Buttons are locked not failure e E5 Material malfunction will be showed by the indicator light on the mother board of outdoor unit GREE_duct_eng_1022 indd 8 T 08 10 27 3 32 06 iR OT TT p Mo TOO REMOTE CONTROLLER OPERATION Precautions Point the remote controller towards the receiver window on the wire controller and press the desired button e Ensure there is no obstacle between the remote controller and the receiver window of the wire controller The remote control can send signals from up to 8 metres away e Never drop or throw at will the remote controller e Never let any liquid enter the remote controller Avoid direct sunshine over the remote controller Do not place the remote controller in an extremely hot place e SWING button is invalid for this unit HSITSNA FAN button Press to set fan speed A FAN Pe AUTOFAN ail crer AUTO i GG ed SWING Receiver window TEMP button Press to set suitable TEMP MODE button mm MODE ON OFF Press to set operation de a ON OFF button Press to start or stop operation Loading Batteries e After batteries are installed the display shall display icons and letter codes of all functions The life of batteries is about 1 year e Do not mix new and old batteries or mix different types of batteries in usage e If the remote controller shall not be us
5. P 9 Colocar as Pilsen P 9 e Funcionamento do modo frio COOL P 10 a Funcionamento do modo quente HEAT P 10 Funcionamento do modo seco DRY P 11 Funcionamento do modo de ventoinha FAN P 11 s FUNGAO Ca unidade tear n P 12 Instru es de instala o da unidade e Dimens es de instala o P 13 e Instala o da unidade do interior P 16 e Instala o do tubo do ar rectangular P 17 e Instala o da tubagem de drenagem P 18 e Instala o do tubo do refrigerante P 18 e Posi o e m todo de instala o do controlo do fio P 21 e Instala o el ctrica eee P 22 e Resolu o de problemas peaa P 24 Manuten o ii P 25 e NAC Eea a a ERHEBT NSW r P 25 Por favor leia este manual com aten o antes de utilizar o produto Este manual dever ser guardado num local seguro para futuras refer ncias P 1 GREE_duct_por_1022 indd 1 dp 08 10 27 3 35 06 INSTRU ES IMPORTANTES DE SEGURAN A AVISOS DE UTILIZA O 1 N o puxe nem deforme o fio da alimenta o Puxar ou usar de modo inadequado o fio da alimenta o pode dar origem a danos na unidade e a choques el ctricos 2 Ten
6. MODE ON OFF f ONVITVLI Premete il tasto ON OFF Q Premete il tasto MODE per seleziona AUTOFAN onen re la modalit FAN see Premete il tasto FAN per selezionare la velocit alta media o bassa hd GREE duct ita 1022 indd 11 de 08 10 27 ssi i cessa p a IT m FUNZIONI DELL UNITA 1 Impostazione dei due sensori di tempe ratura ambiente condizionatori d aria di questa serie sono dotati di due sensori di temperatura am biente Un sensore collocato nell entrata dell aria dell unit interna mentre il secon do collocato all interno del dispositivo di controllo a filo L utente pu selezionare il sensore di temperatura ambiente preferito a seconda dei requisiti di installazione per ulteriori dettagli fate riferimento alla sezione sulle istruzioni per il dispositivo di controllo a filo Il sensore di temperatura ambiente predefinito quello collocato nell entrata dell aria 2 Controllo della temperatura esterna E possibile controllare la temperatura esterna tramite il dispositivo di controllo a filo Per ulteriori dettagli fate riferimento alla sezione sulle istruzioni per il dispositivo di controllo a filo 3 L altezza di mandata della pompa di drenaggio della condensa pu raggiun gere 1 1 m ci rende l installazione meccanica molto semplice e rapida L altezza di mandata
7. 7 Bo TOO FUNZIONAMENTO DEL TELECOMANDO Funzionamento in modalit RAFFREDDAMENTO 1 Premete il tasto ON OFF Q 2 Premete il tasto MODE per seleziona AUTOFAN oem re la modalit RAFFREDDAMENTO s 8 25 3 Premete il tasto Temperatura per im postare la temperatura desiderata MODE ON OFF Funzionamento in modalita RISCALDAMENTO 1 Premete il tasto ON OFF Sn Fa 2 Premete il tasto MODE per seleziona AUTOFAN ceca re la modalit RISCALDAMENTO E 28 3 Premete il tasto Temperatura per im postare la temperatura desiderata In modalit di riscaldamento l unit ha la funzione di prevenire l alimentazione di aria fredda e alimentare calore Dopo l avvio del compressore la ventola interna si avvia quando la temperatura del va porizzatore raggiunge o supera i 35 C o se l unit stata avviata da almeno 45 secondi in modo da evitare che l uni t emetta aria fredda Dopo l arresto del compressore la ventola interna continue r a ruotare per 120 secondi GREE_duct_ita_1022 indd 10 de 08 10 27 ssi Funzionamento in modalita DEUMIDIFICAZIONE 1 Premete il tasto ON OFF ria 2 Premete il tasto MODE per seleziona AUTOFAN crea re la modalit DEUMIDIFICAZIONE S DN RIO id 3 Premete il tasto Temperatura per im postare la temperatura desiderata
8. r o SLEEP TIMER ONIOFF GREE_duct_por_1022 indd 4 e Prima o bot o de configura o da temperatura A para aumentar a temperatura Prima o bot o de configura o da temperatura W para diminuir a temperatura Prima os bot es uma vez e a configurac o da tempe ratura muda 1 C NOTA Fung o de bloqueio dos bot es Quando premir em simult neo os bot es A e V du rante 5 segundos a area de indicac o da temperatura definida apresenta a mensagem EE e todos os bot es ficam bloqueados Para cancelar a fung o de bloqueio dos bot es prima novamente os dois bot es em simult neo durante 5 se gundos Raio da configurag o da temperatura e Quente 16 C 30 C e Frio 16 C 30 C e Seco 16 C 30 C Ventoinha Sem fun o de configura o da temperatura se 08 10 27 3 35 07 A Configuragao da fungao de hibernar e Modo COOL ou DRY Uma hora ap s ter premido o botao SLEEP a tempera tura definida sobe 1 C e ap s 2 horas a temperatura definida sobe mais 1 C e Modo HEAT Uma hora ap s ter premido o bot o SLEEP a tempera tura definida desce 1 C e ap s 2 horas a temperatura definida desce mais 1 C SLEEP TIMER onore e Nao pode escolher a fung o de hibernar durante o mo do de ventoinha Configuragao do modo de funcionamento e Prima o bot o MODE para escolher o modo de funcio namento
9. Installazione del tubo del fluido refrigerante Scelta del tubo del fluido refrigerante Dimensioni del tubo del tubo Altezza massima Quantita di fluido refrigerante re fsa massima Differenza tra l unit interna extra da aggiungere in base Modello Tubo del gas Tubo del fluido e l unit esterna m alla lunghezza extra del tubo Nota e La lunghezza standard del tubo di 5 m Se la lunghezza del tubo supera i 5 m aggiungete del fluido refrigerante come illustrato nella tabella sopra descritta e Utilizzate tubi con uno spessore di 0 8 mm 1 0 mm o 1 2 mm La parete del tubo deve essere in grado di sopportare una pressione di 6 0 MPa e Maggiore la lunghezza del tubo del fluido refrigerante inferiore sar l efficienza del riscaldamen to e del raffreddamento I 18 GREE_duct_ita_1022 indd 18 dp 08 10 27 3 33 41 nee o o TOO Collegamento del tubo 1 Allineate l estremit svasata del tubo in rame con il centro del giunto filettato Serrate manualmente il dado con estremit svasata 2 Utilizzate la chiave dinamometrica per serrare il dado svasato fino allo sferragliamento della chiave mP cold 16 2 Nm Tutore Dall Gil 3844 Nm f 1 0 ae 5546 Nm LOS 7557 Nm 11010 Nm 6 Chiave L Kee Chiave dinamometrica 3 L angolo di piegatura del tubo non deve essere troppo grande altrimenti il tubo potrebbe rompersi Utilizzate un curvatubi per piegare il tubo 4 Avvolgete
10. HEAT will be displayed After setting is completed press the FAN button and the W button simultaneously for 5 seconds to exit the SAVE setting After the SAVE setting interface is activated the system will exit the interface if there is no any operation within 20 seconds after the last button input and the normal shutoff status interface will be displayed After the above settings are completed the system will display SAVE The set temperature will not exceed the temperature range of the SAVE setting For example the lower cooling limit is set to 23 C and the upper cooling limit is set to 27 C so the cooling temperature can only be selected from the range of 23 C to 27 C by using the remote controller or the wire controller If the upper limit temperature is the same as the lower limit temperature the system can only operate at this temperature under corresponding mode To cancel the SAVE setting press the FAN button and the W button simultaneously for 5 seconds when the unit is shut off The value set before will not be cleared but as the initial set temperature for the next energy saving setting After the unit is disconnected to power supply the SAVE setting will be memorised The setting still functions when the unit is connected to power supply again If the SAVE mode is set the sleep mode and the auto mode will be invalidated GREE_duct_eng_1022 indd 6 T 08 10 27 3 32 05 Display of outdoor tem
11. MODE ON OFF f desired temperature HSITONA Press the ON OFF button Q Press the MODE button to select FAN AUTOFAN open Ky mode see Press the FAN button to select from high medium and low speed E e dh GREE_duct_eng_1022 indd 11 T 08 10 27 eal i cessa UNIT FUNCTION 1 Setting of Double Room Temperature Sensors This series of ducted air conditioning unit has two room temperature sensors One is located at the air intake of the indoor unit and the other one is located inside the wire controller User can select one from the two room temperature sensors on the basis of the engineering requirement Refer to the section of wire controller instructions for detailed operation The default room temperature sensor is the one located at air intake 2 Checking of Outdoor Temperature The outdoor temperature can be checked on the wire controller Refer to the section of wire controller instructions for detailed operation 3 The head of delivery of the condensate drainage pump can reach 1 1m so that the engineering installation is very convenient and prompt Head of delivery of pump is 1100mm GREE_duct_eng_1022 indd 12 p Mo el WLLL LLLLLLL LAL LLELL Ly le 4 Room temperature sensor A A A Room temperature sensor B FIPISEEEPTELIELLLILTENS Outdoor side Indoor side Outdoor sensor M
12. Hight Auto I r Press the buttons once the temperature setting will change by 1 C NOTE Button lock function When the A and W buttons are pressed simultaneously for 5 seconds the set temperature SLEEP TIMER ON OFF e Press the temperature setting button A to rise the set temperature Press the temperature setting button W to drop the set temperature GREE_duct_eng_1022 indd 4 indicating area will display EE and all buttons response will be shut off To cancel the button lock function press the two buttons simultaneously for 5 second again Range of temperature setting e Heat 16 C 30 C e Cool 16 C 30 C e Dry 16 C 30 C Fan No temperature setting function de 08 10 27 3 32 04 m Sleep function setting COOL or DRY mode One hour after the SLEEP button is pressed the set temperature rises by 1 C and after 2 hours the set temperature rises by additional 1 C HEAT mode One hour after the SLEEP button is pressed the set temperature drops by 1 C and after 2 hours the set temperature drops by additional 1 C HSITOSNA SLEEP TIMER onor Sleep function cannot be set during Fan mode Operating mode setting Press the MODE button to select the operation mode S i COOL DRY gt FAN gt HEAT gt AUTO 7 v 20 COOL mode E
13. Never install the wire controller in a place where is water leakage Avoid bumping throwing tossing or frequently opening the wire controller TIMER III C ONOFF III Lg HR AUTO EN 2 FAN W h MN ERROR SPEED W SLEEP SAVE SET OUT ENV mu O a O u ees a II rest SLI AUTO COOL DRY FAN HEAT d OOO PPPA DEFROST display SAVE display Set temperature display Ambient temperature display Mode cool dry fan heat auto display Failure display SLEEP display MODE button Temperature setting button for temperature rise Temperature setting button for temperature drop FAN button SLEEP button outdoor temperature check TIMER button ON OFF button GREE_duct_eng_1022 indd 3 Receiver window HSITSNA 08 10 27 3 32 03 1 i cessa E o SER WIRE CONTROLLER OPERATION ON OFF pas AUTO EN E SPEED COOL Bee Gage e Press the ON OFF button the unit will start up Press the ON OFF button again the unit will turn off a Fan control the figures show the relevant display areas a FAN SPEED MW FAN In the DRY mode the fan speed will be automatically set to Low SLEEP TIMER ON OFF Press FAN button to change fan speed ia Low gt Medium
14. SHARP GB X18JR GU X18JR GB X24JR GU X24JR GB X36JR GU X36JR GREE_duct_cov_1022 indd 1 q TT es Mo TOO SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL CONDIZIONATORE D ARIA DA CAMERA TIPO SPLIT MANUALE PER L INSTALLAZIONE E IL FUNZIONAMENTO AR CONDICIONADO DE SALA DE DUAS UNIDADES MANUAL DE OPERAGAO E DE INSTALAGAO 08 10 27 3 30 13 HSITSNA gt gt z e SINONLHYOd OT TT p a 11 Im Attention Your product is marked with this symbol It means that used electrical and electronic products should not be mixed with general household waste There is a separate collection system for these products PD GREE_duct_cov_1022 indd 2 A Information on Disposal for Users private households 1 In the European Union Attention If you want to dispose of this equipment please do not use the ordinary dust bin Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment recovery and recycling of used electrical and electronic equipment Following the implementation by member states private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge In some countries your local retailer may also take back your old product free of charge if you purchase a similar new one Plea
15. ii DRY FAN E v a s6 o Modo frio COOL SINONLYOd AUTO COOL DRY FAN HEAT men O ON OFF A temperatura definida tem de ser inferior a tempe ratura na sala Se a temperatura definida for superior a temperatura na sala a unidade nao produz o efeito de arrefecimento e funciona apenas no modo de ven toinha Modo seco DRY O motor da ventoinha funciona a baixa velocidade aum raio de temperatura especifico O efeito desu midificador neste modo amp melhor do que o do modo COOL e poupa mais energia Modo quente HEAT A temperatura definida tem de ser superior a tempe ratura na sala Se a temperatura definida for inferior a temperatura da sala a fung o de aquecimento nao come a Modo AUTO A unidade ajusta automaticamente o seu modo de fun cionamento de acordo com a temperatura ambiente No aquecimento se a temperatura no exterior for bai xa e a humidade alta aparece gelo na unidade do ex terior A efici ncia de aquecimento diminui Quando aparecer gelo a unidade come a automati camente a descongelar e aparece a mensagem DE FROST GREE duct por 1022 indd 5 sp 08 10 27 3 35 08 4 Configuragao do temporizador e Quando a unidade n o estiver a funcionar pode defi nir o temporizador de in cio Quando a unidade estiver e 13 00 a funcionar pode definir o temporizador de desligar gt TRE Oraio da configura o d
16. GB X24JR GB X36JR 08 10 27 3 35 11 4 Dimensoes de instalac o Unidade no interior GB X18JR A G mu a p E C Caixa el ctrica Tubo do liquido Tubo do gas Li D TRES ETA T 7 Entrada mn x do ar i it Q E E Tubo de drenagem g 3 Entrada do ar a 9 m 7 GB X24JR GB X36JR GB X24JR GB X36JR A A L c C a D D E E Caixa el ctrica Entrada FO dt Ef 1 A a o T er ffe f a El E HEI La Mi Ll E lex u L Tubo de drenagem Tubo do g s Tubo do l quido Unidade de medi o mm ANS angna Tubo de drenagem Tubo de liga o Tubo de liga o A A Cc E F G H J ga 920 Di metro exterior x A Tubo do l quido Tubo do g s Grossura da parede GREE duct por 1022 indd 13 de 08 10 27 sai ii cous Ho 11 01 INSTRU ES DE INSTALA O DA UNIDADE GB X18JR MMM yy PREGA HA A Z WA ee do Z 7 g Prr ee de 9 2 Mola da f J f Porca a A Yy PE MIN 250 MIN 250 GB X24JR GB X36JR VILLLLGLLLLLLELLL ALLL p F orcacom Anilha de Mola da Porca r anilha A E E y WY i 7 7 De Ce A J 5 E MIN 2 500 E u MIN 250 MIN 250 Unidade de medi o mm Aviso A altura da instala o da
17. alimentazione Manutenzione al termine della stagione Quando sereno azionate l unit in modalit ventola per mezza giornata in modo da asciugare la parte interna dell unit e Se il condizionatore d aria non sar usato per un lungo periodo di tempo scollegate l alimentazio ne Il display LCD del dispositivo di controllo a filo non visualizzer nulla Appendice Condizioni di funzionamento nominali e gamma di funzionamento del condizionatore d aria sin p DB C WB C DB C WB C Riscaldamento nominae 20 7 6 Raffreddamentominimo 2 s 18 Riscaldamento massimo 27 a 18 Riscaldamento minmo 20 7 Nota Il design di questa unit conforme ai requisiti dello standard EN14511 Il volume dell aria si misura in base alla relativa pressione statica esterna standard e La capacit di raffreddamento riscaldamento sopra indicata si misura in condizioni di funziona mento nominali corrispondenti alla pressione statica esterna standard parametri sono soggetti a modifiche per il miglioramento dei prodotti in questo caso fate riferimento ai valori sulla targhetta di identificazione I 25 GREE_duct_ita_1022 indd 25 de 08 10 27 3 33 43 7 Mo al A Informa es sobre a Elimina o de Produtos para os Utilizadores particulares 1 Na Uni o Europeia Aten o Se quiser eliminar este equipamento n
18. 2 N o existe fonte de calor ou existe muita gente dentro da sala 3 A porta ou janela est aberta Fraco efeito de 4 Existe um obst culo na entrada ou sa da do ar arrefecimento 5 A temperatura definida muito elevada impedindo assim o arrefecimento 6 H uma fuga do l quido refrigerante 7 O desempenho do sensor da temperatura ambiente piora 1 O filtro do ar est sujo ou bloqueado 2 A porta ou janela n o est bem fechada Fraca sicito do 3 Pt gle definida muito baixa impedindo assim o aque aquecimento 4 H uma fuga do liquido refrigerante 5 A temperatura ambiente no exterior inferior a 5 C 6 A linha de controlo anormal Nota Ap s efectuar a verificag o dos pontos apresentados acima e tomar as devidas medidas para resolver os problemas se a unidade de ar condicionado continuar sem funcionar bem pare ime diatamente o funcionamento da unidade e contacte o agente de repara o local designado pela SHARP Somente um agente de repara o profissional deve reparar a unidade P 24 GREE duct por 1022 indd 24 dp 08 10 27 sui TT p Bo 11 Im Manutenc o Manuten o de rotina Limpeza do filtro do ar efectuada por um profissional N o desmonte o filtro do ar quando o estiver a limpar Caso contr rio pode dar origem a falhas Se o ar condicionado for usado em ambientes com muito p dever limpar o filtro do ar frequente mente uma vez a cada duas semanas
19. 220 240V 50Hz Dl a 220 240V 50Hz 1 Cavo di alimentazione 3G 2 5 mm HO7RN F 2 Cavo di alimentazione 3G 1 0 mm HO5W F scheda scheda 3 Filo di comunicazione Tipo UL2835 doppino intrecciato madre madre Dimensione AWG24 GB X36JR Unita esterna Unita interna ALIMENTAZIONE 220 240V 50Hz ALIMENTAZIONE 220 240V 50Hz 1 Cavo di alimentazione 3G 6 0 mm HO7RN F 2 Cavo di alimentazione 3G 1 0 mm HO5W F scheda madre scheda 3 Filo di comunicazione Tipo UL2835 doppino intrecciato madre Dimensione AWG24 I 23 GREE_duct_ita_1022 indd 23 de 08 10 27 3 33 43 ii cous o 11 01 ISTRUZIONI PER L INSTALLAZIONE DELL UNIT Risoluzione dei problemi Se il condizionatore d aria presenta un funzionamento anomalo o guasti controllate innanzitutto i seguenti punti prima di procedere con la riparazione Guasto Possibili cause 1 Il cavo di alimentazione non collegato ii 2 Perdite elettriche del condizionatore d aria hanno fatto scattare I l interruttore di protezione dalle perdite 3 tasti di funzionamento sono bloccati 4 C stato un guasto nel circuito di controllo unit funziona 1 presente un ostacolo davanti all unit condensante per un certo 2 Il funzionamento del circuito di controllo presenta delle i RER anomalie periodo quindi si 3 Loperazione di raffreddamento viene selezionata quando arresta la temperatura ambiente esterna superio
20. CN10 del dispositivo di controllo a filo si collega con CN3 dell unita interna 4 Fissate il cavo del segnale del dispositivo di controllo a filo con dispositivo di fissaggio per cavi Interruttore differenziale Installate un interruttore differenziale per garantire la protezione da scosse elettriche in caso di perdite e Utilizzate un interruttore differenziale del tipo a corrente ad alta sensibilit e ad alta velocit con corrente di sensibilit nominale inferiore a 30 mA e tempo di funzionamento inferiore a 0 1 secondi Requisiti per la messa a terra e Collegate correttamente il condizionatore d aria con messa a terra Non collegate il cavo di messa a terra a tubi del gas tubi dell acqua parafulmini o al cavo di messa a terra del telefono Un colle gamento di messa a terra incompleto potrebbe causare scosse elettriche Il filo a due colori giallo verde del condizionatore d aria il filo di messa a terra e non pu essere utilizzato per altri scopi Non possibile tagliare o fissare questo filo con una vite in caso contra rio ci pu provocare scosse elettriche gt gt z fe Diagramma di collegamento dei cavi dell unita L area della sezione dei cavi selezionata dall utente non deve essere inferiore alle specifiche indicate nel diagramma Diagramma schematico del collegamento di linea dell unit GB X18JR GB X24JR Unita esterna Unita interna L t ALIMENTAZIONE ALIMENTAZIONE
21. E 10 Dry mode Operation ansehen E 11 Fan mode operation i E 11 Unit FUNCUOM een ernennen E 12 Installation Instructions e Installation dimensions iii E 13 e Installation of indoor unit E 16 e Installation of rectangular air pipe E 17 e Installation of drainage pipeline E 18 e Installation of refrigerant pipe nennen E 18 e Position and method of installing wire controller E 21 e Electrical installation ii E 22 s TPOUDISSMOOUNG wise criari E 24 e Maintenance nn E 25 APPENDIX siria E 25 Please read this manual carefully before using the product This manual should be kept in a safe place for handy reference GREE_duct_eng_1022 indd 1 lt gt HSITSNA 08 10 27 3 32 03 1 IMPORTANT SAFETY INSTRUCTIONS WARNINGS FOR USE 1 Do not pull or deform the power supply cord Pulling and misuse of the power supply cord can result in damage to the unit and cause electrical shock 2 Be o not to expose your body directly to the outlet air for a long time It may affect your physical conditions 3 When using the air conditioner for infants children elderly bedridden or disabled people make sure the room temperature is suitable for those in the room Never insert objects into the unit Inserting objects can result in injury due to the high spe
22. UE Se si desidera eliminare il presente prodotto contattare le autorit locali e informarsi sul metodo di smaltimento corretto La batteria fornita con questo prodotto contiene tracce di Piombo Per EU Il cassonetto barrato indica che le batterie usate non devono essere gettate assieme ai rifiuti domestici Vi un sistema di raccolta differenziata per le batterie usate che consente il loro corretto trattamento e riciclo secondo quanto previsto dalle leggi vigenti Vi prego di contattare le locali autorit per i dettagli del sistema di raccolta e riciclaggio Per la Svizzera Le batterie usate devono essere restituite al punto vendita Per altri Stati non EU Vi prego di contattare le autorit locali per conoscere il metodo corretto di conferimento delle batterie usate 08 10 27 3 30 14 GREE_duct_ita_1022 indd 1 aE INDICE Istruzioni per l uso e Importanti istruzioni per la sicurezza eee e eee l 2 e Funzionamento del dispositivo di controllo a filo 1 3 CNO al aoe eer on er eee ter rrr eer ern N ere ee 1 4 Controllo ventola eee eererene l 4 Impostazione della temperatura ii l 4 Impostazione della funzione di attesa l 5 Impostazione della modalit di funzionamento 1 5 Impostazione del timer is l 6 Impostazione SAVE eira l
23. at the air intake or outlet The set temperature is too high thus cooling is hindered There is refrigerant leakage The performance of room temperature sensor becomes worse Poor cooling effect NOORWN The air filter is dirty or blocked The door or window is not firmly closed The set room temperature is too low thus heating is hindered There is refrigerant leakage The outdoor ambient temperature is lower than 5 C Control line is abnormal Poor heating effect DA BON Note After carrying out the check of the above items and taking relevant measures to solve the problems found but the air conditioning unit still does not function well stop the operation of the unit immediately and contact the local service agency designated by SHARP Only ask professional serviceman to check and repair the unit E 24 GREE duct eng 1022 indd 24 T 08 10 27 ui TT p Bo 11 Im Maintenance Routine maintenance Cleaning the Air Filter Operating by the professional Do not disassemble the air filter when cleaning it Otherwise failure may be caused If the air conditioner is used in an environment with much dust you should clean the air filter frequently once every two weeks Caution Pay attention to the following matters when cleaning the air conditioning unit Cut off all power supply before contacting the line connecting equipment e Only clean the air cond
24. consigliati Modello Interruttore disgiuntore Area della sezione trasversale minima del cavo di alimentazione EXIBIR o 240 V 50 Ha 2 2 GB X24JR 220 240 V 50 Hz 6A 1 0 mm GUX24JR GB X36JR 220 240 V 50 H GU X36JR e Se il cavo di alimentazione di lunghezza superiore a 15 metri ampliate in maniera adeguata la sezione trasversale del cavo di alimentazione per evitare incidenti provocati da sovraccarico l 22 TT p a 11 Im Attenzione Prestate molta attenzione quando eseguite i seguenti collegamenti in modo da evitare malfunziona menti del condizionatore d aria a causa di interferenze elettromagnetiche La linea del segnale del dispositivo di controllo a filo deve essere separata dalla linea di alimenta zione e dalla linea di collegamento tra l unit interna e l unit esterna Nel caso in cui l unit sia installata in un luogo soggetto ad interferenze elettromagnetiche si consi glia di utilizzare un cavo schermato o un cavo doppio ritorto come linea del segnale del dispositivo di controllo a filo Collegamento della linea del segnale del dispositivo di controllo a filo 1 Aprite il coperchio del pannello elettrico nell unit interna 2 Fate passare il cavo del segnale del dispositivo di controllo a filo attraverso l anello in gomma 3 Inserite la linea del segnale del dispositivo di controllo a filo nella presa con pin a 4 bit della sche da del circuito nell unit interna
25. contr rio o sistema conside rar a temperatura superior como a temperatura limite superior e a temperatura inferior como a temperatura limite inferior Prima o bot o MODE para completar a configura o de SAVE guardar para os modos de arrefecer e desumidificar e passar para a configura o de SAVE guardar para o modo de aquecimento SAVE e HEAT ser o apresentados Ap s a configura o estar termi nada prima o bot o FAN e o bot o W em simult neo durante 5 segundos para sair da configura o de SAVE guardar Ap s o interface da configura o de SAVE ser activado o sistema sai do interface caso n o haja qualquer opera o no espa o de 20 segundos ap s ter premido pela ltima vez um bot o e ser apresentado o interface do estado do desligar normal Ap s as configura es apresentadas acima estarem completas o sistema apresenta a mensagem SAVE A temperatura definida n o excede o raio da temperatura da configura o SAVE guardar Por exemplo se o limite de arrefecimento inferior estiver definido para 23 C e o limite de arrefecimento superior estiver definido para 27 C a tem peratura de arrefecimento s pode ser seleccionada entre os 23 C e os 27 C usando o comando dist ncia ou o controlador do fio Se a temperatura limite superior for a mesma que a temperatura limite inferior o sistema s pode funcionar a esta temperatura no modo correspondente Para cancelar a configura o de SAVE
26. dalla fabbrica entrambe le uscite di drenaggio sono bloccate da tubi in gomma Quando collegate il tubo di drenaggio all unit non applicate eccessiva pressione sulle tubature sul lato dell unit La posizione di fissaggio delle tubature dev essere vicino all unit e Acquistate tubi in PVC duro universali da utilizzare come tubature di drenaggio in zona Quando eseguite i collegamenti collocate l estremit della tubatura in PVC nel foro di drenaggio Utilizza te un tubo di drenaggio flessibile e serratelo con un anello filettato Non utilizzate materiale adesi vo per collegare il tubo di drenaggio flessibile al foro di drenaggio e Se il tubo di drenaggio viene usato per diverse unit il tubo comune dovrebbe essere posiziona to ad almeno 100 mm pi in basso rispetto all uscita di drenaggio di ciascun set di unit A questo scopo si consiglia di utilizzare un tubo con pareti pi spesse Materiali di isolamento termico del tubo di drenaggio Tubature di scarico Attenzione Il giunto del tubo della condensa non deve presentare perdite Collaudo del sistema di drenaggio 1 Dopo aver completato l installazione elettrica eseguite il collaudo del sistema di drenaggio 2 Durante il collaudo verificate che l acqua scorra senza problemi nelle tubature Osservate atten tamente i giunti per garantire che non vi siano perdite Se l unit sar installata in una casa nuova eseguite il collaudo prima di decorare il soffitto
27. della pompa di 1 100 mm GREE_duct_ita_1022 indd 12 DEISE MAEM EME SS ILD ELT Sensore di temperatura ambiente A NR Sensore di temperatura ambiente B SWVESET EESIOUTENV BE PARRA 7 MLLLLL LLL ELL LLL Di e A Lato esterno Lato interno yy ln i rA Sensore esterno 7 p Y A VI LE A pompa GB X24JR GB X36JR vill Im WI Mr n Je mil Il IMI jl M S 08 10 27 3 33 39 Li GREE_duct_ita_1022 indd 13 sb 08 10 27 3 33 39 Li ISTRUZIONI PER L INSTALLAZIONE DELL UNIT Dimensioni di installazione Unit interna GB X18JR A _ G mu H p a gt E L C al gt Pannello elettrico Tubo del fluido Tubo del gas L D ry _ x 3 Entrata sa I 5 dell aria ru Ly I Q E Tubo di drenaggio Entrata dell aria GB X24JR GB X36JR ease EXER Il h a NH l A A ay ua ua 4 TE 1 L c J L C J D D E E Pannello elettrico Entrata zo Nei dell aria ea h prea EBEN al E ni t 4 1 Force Udo S AZ R TAL h Tubo di drenaggio Tubo del gas Tubo del fluido Unit di misura della lunghezza mm Tubo Tubo Tubo di drenaggio G di collegamento di collegamen
28. escolher AUTOFAN open o modo COOL y frio ace 3 Prima o bot o da temperatura para escolher a temperatura desejada MODE ON OFF Funcionamento do modo quente HEAT 1 Prima o bot o ON OFF aS Sa Fa 2 Prima o bot o MODE para escolher o AUTOFAN PeR modo HEAT y quente a 28 3 Prima o bot o da temperatura para escolher a temperatura desejada No modo de aquecimento a unidade tem fung es para prevenir o abasteci mento de ar frio e fornecer o calor res tante Ap s a ligac o do compressor a ventoinha interior comeca a funcionar quando a temperatura do evaporador for igual ou superior a 35 C ou ap s a unidade ser ligada durante 45 segundos para prevenir o fluxo de ar frio de sair da unidade Ap s a paragem do com pressor a ventoinha interior roda duran te 120 segundos GREE_duct_por_1022 indd 10 dp 08 10 27 ui Se fs SWING FAN AUTOFAN OPER z 25 i i e qc SWING FAN AUTOFAN OPER DG e dh GREE_duct_por_1022 indd 11 1 Prima o bot o ON OFF Prima o bot o MODE para escolher o modo DRY x seco Prima o bot o da temperatura para escolher a temperatura desejada SINONLYOd Prima o bot o ON OFF Prima o bot o MODE para escolher o modo FAN Prima o bot o FAN para escolher en tre a velocidade alta m d
29. g s Uma ventila o insuficiente pode dar origem a uma redu o do oxig nio 2 N o utilize os bot es com a m o molhada Isso pode dar origem a choques el ctricos 3 Para sua seguran a desligue o disjuntor quando n o usar a unidade durante um longo per odo de tempo 4 Verifique a grelha de montagem exterior da unidade quanto a desgaste e certifique se de que esta est colocada firmemente no devido lugar 5 N o coloque nada em cima da unidade exterior nem a pise O objecto ou a pessoa podem cair podendo dar ori gem a les es 6 Esta unidade foi criada para uma utiliza o dom stica N o a use noutras aplica es como num canil estufa para criar animais ou para criar plantas 7 N o coloque um vaso com gua em cima da unidade Se entrar gua dentro da unidade o isolamento el ctrico pode deteriorar e dar origem a um choque el ctrico 8 N o bloqueie as entradas nem as sa das de ar da unidade Isso pode dar origem a um funcionamento insuficiente ou problemas 9 Certifique se de que p ra o funcionamento e desliga o disjuntor antes de efectuar qualquer manuten o ou limpe za Existe uma ventoinha a rodar dentro da unidade que pode dar origem a les es 10 N o borrife nem deite gua em cima da unidade A gua pode causar um choque el ctrico ou danos no equipa mento 11 Este aparelho n o foi criado para ser usado por crian as pequenas ou pessoas deficientes sem a devida supervis o As crian as pequenas dever o se
30. guardar prima o bot o FAN e o bot o W em si mult neo durante 5 segundos quando a unidade for desligada O valor definido antes s ser apagado para a temperatura definida inicialmente para a pr xima configura o de poupan a de energia Ap s a unidade ser desligada da alimenta o a configura o SAVE guardar ser me morizada A configura o continua a funcionar quando a unidade for ligada novamente alimenta o Se o modo SAVE guardar for escolhido o modo de hibernar e o modo autom tico ser o invalidados GREE_duct_por_1022 indd 6 dp 08 10 27 3 35 09 Apresentag o da temperatura no exterior S Em condi es normais apresentado ENV e a tem on I peratura da sala Prima o bot o SLEEP durante 5 se gundos O LCD apresenta a mensagem OUT ENV a A temperatura no exterior aparece no ecra durante v 10 segundos e depois volta temperatura da sala OUTENV gt a FAN Ss E SLEEP TIMER ON OFF Configuragao da fung o de memoria Quando a unidade desligada prima o bot o MODE li Es durante 10 segundos para ligar os valores definidos e decidir se o estado de funcionamento da unidade ou o estado de desligar memorizado ap s uma falha de SINONLYOd A E energia 56 Se a area da temperatura definida apresentar 01 significa que o estado de funcionamento da unidade E ser memorizado ap s uma f
31. modalit migliore rispetto a quello che si ottiene nella modalit di RAFFREDDAMENTO e consente di risparmiare pi energia Modalit RISCALDAMENTO HEAT La temperatura impostata deve essere superiore alla temperatura ambiente Se la temperatura impostata inferiore rispetto alla temperatura ambiente la funzione di riscaldamento non si avvia Modalit AUTO L unit regola la modalit di funzionamento in maniera automatica a seconda della temperatura ambiente SLEEP AUTO COOL DRY FAN HEAT men O ON OFF Se durante il riscaldamento la temperatura bassa e l umidit elevata sull unit esterna si former del ghiaccio Di conseguenza l efficienza del riscaldamen to si riduce Nel caso in cui si formi del ghiaccio l unit avvier au tomaticamente l operazione di scongelamento e sar visualizzato DEFROST GREE_duct_ita_1022 indd 5 ae 08 10 27 3 33 35 FUNZIONAMENTO DEL DISPOSITIVO DI CONTROLLO A FILO Impostazione del timer e Quando l unit non in funzione possibile imposta TETTE re il timer di accensione Quando l unit in funzione mer 15 20 possibile impostare il timer di spegnimento La gam ns ma di impostazioni del timer varia tra 0 5 e 24 ore 1 Premete il tasto TIMER per impostare il timer come desiderato TIMER lampeggia sul display 2 Premete il tasto A o W per aumentare o ridurre l interva
32. o o deve fazer juntamente com o lixo dom stico comum O equipamento el ctrico e electr nico deve ser tratado separadamente e ao abrigo da SS legislac o aplicavel que obriga a um tratamento recuperac o e reciclagem adequados de equipamentos el ctricos e electr nicos usados Ap s a implementa o desta legisla o por parte dos Estados membros todos os Aten o O seu produto i 5 i A a R cidad os residentes na Uni o Europeia poder o entregar o seu equipamento el ctrico esta identificado com este simbolo Significa que os e electr nico usado em estac es de recolha especificas a titulo gratuito produtos electricos e Em alguns paises o seu revendedor local tamb m pode recolher o seu equipamento electr nicos n o devem ser usado a t tulo gratuito na compra de um novo equipamento misturados com o lixo Contacte as entidades locais para mais informa es dom stico comum Existe Se o seu equipamento el ctrico e electr nico usado funcionar a pilhas ou baterias dever um sistema de recolhas elimin las em separado conforme a legisla o local e antes de entregar o seu equipamento espec fico para estes produtos Ao eliminar este produto correctamente estar a contribuir para que o lixo seja submetido aos processos de tratamento recupera o e reciclagem adequados Desta forma poss vel evitar os efeitos nocivos que o tratamento inadequado do lixo poderia provocar no ambiente e na sa de 2 Em outros
33. per pulirlo In caso contrario potrebbero verificarsi dei guasti e Se il condizionatore d aria viene usato in un ambiente molto polveroso necessario pulire il filtro dell aria pi spesso una volta ogni due settimane Attenzione Prestate attenzione a ci che segue quando pulite il condizionatore d aria e Scollegate tutte le fonti di alimentazione prima di eseguire un contatto con l apparecchiatura di collegamento di linea e Pulite il condizionatore d aria solo dopo aver spento l unit e scollegato l alimentazione In caso contrario potrebbero verificarsi lesioni o scosse elettriche Non utilizzate acqua per pulire il condizionatore d aria In caso contrario potrebbero verificarsi scosse elettriche e Utilizzate un piedistallo stabile gt gt z fe Manutenzione all inizio della stagione In caso di condizioni anomale rivolgetevi al personale di servizio per consigli su come procedere e Controllate l entrata e l uscita dell aria nelle unit interna ed esterna per verificare che non siano bloccate e Controllate che il filo di messa a terra sia in buone condizioni questa operazione deve essere eseguita da personale qualificato Controllate che il collegamento di linea sia in buone condizioni questa operazione deve essere eseguita da personale qualificato e Controllate eventuali avvertimenti sul display LCD del dispositivo di controllo a filo dopo aver collegato l unit all
34. questo manuale prima di usare il prodotto Conservare questo manuale in un luogo sicuro per poterlo consultare facilmente l 1 gt gt z fe 08 10 27 3 33 34 4 IMPORTANTI ISTRUZIONI PER LA SICUREZZA AVVERTENZE D USO 1 Non tirate o deformate il cavo di alimentazione Se il cavo viene tirato o utilizzato in maniera inappropriata l unit si pu danneggiare e si possono provocare scosse elettriche 2 Fate attenzione a non esporvi direttamente all uscita dell aria per un lungo periodo di tempo Ci potrebbe arrecare danni alla vostra salute 3 Quando usate il condizionatore d aria per bambini anziani persone costrette a letto o disabili assicuratevi che la temperatura della stanza sia adeguata 4 Non inserite in nessun caso oggetti nell unit Ci potrebbe provocare lesioni causate dell alta velocit di rotazione delle ventole interne 5 Collegate correttamente il condizionatore d aria con messa a terra Non collegate il cavo di messa a terra a tubi del gas tubi dell acqua parafulmini o al cavo di messa a terra del telefono Un collegamento di messa a terra incom pleto potrebbe causare scosse elettriche 6 In caso di anomalie nel condizionatore d aria per esempio odore di bruciato interrompete immediatamente l uso dell unit e spegnete l interruttore disgiuntore 7 Questa apparecchiatura deve essere installata in linea con le normative di cablaggio nazionali Un collegamento sc
35. rischio di scosse elettriche 8 Non bloccate l uscita e l entrata dell aria dell unit Ci potrebbe comprometterne il funzionamento o provocare guasti 9 Assicuratevi di spegnere l unit e l interruttore disgiuntore prima di eseguire lavori di manutenzione o pulizia Le ventole rotanti all interno dell unit potrebbero provocare lesioni personali 10 Non spruzzate o gettate acqua direttamente sull unit L acqua potrebbe provocare scosse elettriche o danni all unit 1 Questa unit non deve essere usata da bambini o persone inferme senza supervisione Tenete costantemente sotto controllo i bambini affinch non giochino con l unit 12 Dopo aver avviato il condizionatore d aria questo non pu essere arrestato per almeno 5 minuti in caso contrario potrebbero verificarsi problemi per il ritorno dell olio al compressore AVVERTENZE PER L INSTALLAZIONE RIMOZIONE RIPARAZIONE Non cercate di installare rimuovere riparare l unit da soli Interventi scorretti possono provocare scosse elettriche perdite d acqua incendi ecc Consultate il vostro rivenditore o il personale di servizio qualificato per l installazione ri mozione riparazione dell unit e Questa unit pu essere utilizzata in uffici ristoranti residence e luoghi simili Installate l unit in un luogo abbastanza solido da poter sostenere il peso del condizionatore d aria In caso contra rio il condizionatore d aria potrebbe cadere provo
36. sun shield as the protection Place of installation must be able to drain the rainwater and defrosting water e Place of installation must ensure the machine will not be buried under snow or subject to the influence of rubbish or oil fog The installation site must be at a place where the air exhaust outlet does not face strong wind E 15 GREE_duct_eng_1022 indd 15 T 08 10 27 ui ii cous Ho 11 01 INSTRUCTIONS OF UNIT INSTALLATION Installation of indoor unit section of Installation Site Ensure that the top hanger frame has enough strength to support the weight of the unit The drainage pipe shall be easy to drain water There shall be no obstacle at the inlet and outlet so as to keep the air in good circulation Ensure the space needed for installation repair and maintenance works Select a place far from heat source flammable gas or smoke The unit is ceiling mounted Concealed installed in the ceiling The indoor unit outdoor unit power cord and connection cable shall be kept 1m at least from the TV setor radio This is to prevent image interference and noise on above appliances Installation of indoor unit 1 Insert a M10 expansion bolt into the hole Punch the iron nail into the bolt Refer to the H Cp profile dimensions drawing of the indoor unit GA ee for the distance between the holes A 44 2 Install the hanger to the indoor unit n Air conditioning Unit Ceiling mount
37. 0 CAUTIONS FOR LOCATION INSTALLATION e Make sure to connect the air conditioner to power supply of the rated voltage and frequency ee of a power supply with improper voltage and frequency can result in equipment damage and possible ire Do not install the unit in a place where inflammable gas may leak It may cause fire Install the unit in a place with minimal dust fumes and moisture in the air Arrange the drain hose to ensure smooth drainage Insufficient drainage may cause wetting of the room furni ture etc e Make sure an earth leakage breaker or a circuit breaker is installed depending on the installation location to avoid electrical shock e Before use please check and confirm if the cables drainage pipes and pipelines are correctly connected hence to eliminate the risk of water leakage refrigerant leakage electric shock or fire Please do not expose the air conditioner unit directly under corrosive environment with water or moisture n i installation the air conditioner unit shall be energized for electrical leakage test Operating by professina An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring The temperature of refrigerant circuit will be high keep the interconnection cable away from the copper pipe E 2 GREE_duct_eng_1022 indd 2 T 08 10 27 3 32 03 See o o 11 01 WIRE CONTROLLER OPERATION WARNING
38. 1622 Nm Unit E 3844 N m i STREET 55 6 N m 7547 Nm I fo TOHO Nm Kee Torque Wrench HSITSNA Wrench L 3 The bending angle of the pipe shall not be too large and otherwise the pipe may break Use a pipe bender to bend the pipe 4 Wrap the refrigerant pipe and joint in sponge then bind the sponge with plastic tape Air removal 1 Remove both valve shaft caps of the stop valves 2 Remove the service port cap of the stop valve gas side 3 Connect the gauge manifold hose to the service port and the vacuum pump Be sure that the hose end to be connected to the service port has a valve core pusher 4 Open the gauge manifold valve and operate the vacuum pump for 10 15 minutes Make sure the compound gauge reads 76cmHg 5 Close the gauge manifold valve 6 Turn off the vacuum pump 7 Fully open the stop valve liquid side with hexagon socket screw key diagonally 4 mm Turn all the way up to contact 8 cd open the stop valve gas side with hexagon socket screw key Turn all the way up to con act 9 Disconnect the gauge manifold hose from the service port 10 Replace the service port cap and both valve shaft caps tightly Notes e Use a gauge manifold and hoses exclusive for R410A After air removal check the tube connections for gas leak using a leakage detector or soapy water Regarding leakage detector use high sensitivity type designed specially for R410A HINDOOR UNIT Gauge manifold Compo
39. 6 Visualizzazione della temperatura esterna l 7 Impostazione della funzione di memoria l 7 Impostazione del sensore di temperatura ambiente l 7 Visualizzazione QUASI sooner ana l 8 e Funzionamento del telecomando l 9 Installazione delle batterie ernennen l 9 Funzionamento in modalit di raffreddamento l 10 Funzionamento in modalit di riscaldamento l 10 Funzionamento in modalit di deumidificazione I 11 Funzionamento in modalit FAN I 11 Funzioni del UA Maisie 5 he caio I 12 Istruzioni per l installazione e Dimensioni di installazione isrerereeeeeeea I 13 e Installazione dell unita interna series I 16 e Installazione dell tubo rettangolare dell aria I 17 e Installazione delle tubature di scariCo I 18 e Installazione del tubo del fluido refrigerante I 18 e Posizione e metodo di installazione del dispositivo di controllo a FIO eereeereeeeereeeereeaereannra 1 21 Installazione elettrica eeereereeerereeenreta l 22 e Risoluzione dei problemi l 24 Manutenzione astenia I 25 t APPENdICE nu hinaus l 25 Leggere attentamente
40. 8JR GB X24JR Unidade no Unidade no exterior interior ALIMENTAGAO 220 240 V 50 Hz ALIMENTAGAO 220 240 V 50 Hz 1 Fio da alimenta o 3G 2 5 mm HO7RN F Gentile Ben 2 Fio da alimenta o 3G 1 0 mm Hosw F 3 Fio de comunica o Tipo UL2835 de par torcido Tamanho AWG24 GB X36JR Unidade no Unidade no ALIMENTAGAO exterior interior 220 240 V 50 Hz ALIMENTAGAO 220 240 V 50 Hz 1 Fio da alimenta o 3G 6 0 mm HO7RN F i 5 E 2 a peated 2 Fio da alimenta o 3G 1 0 mm HOSW F 3 Fio de comunicag o Tipo UL2835 de par torcido Tamanho AWG24 P 23 ii cous o 11 71 INSTRU ES DE INSTALA O DA UNIDADE Resolu o de problemas Se a sua unidade de ar condicionado funcionar de modo anormal ou sofrer uma falha verifique pri meiro os seguintes pontos antes de a entregar para repara o Falha Poss veis raz es 1 A alimenta o n o est ligada 2 A fuga el ctrica da unidade de ar condicionado causa o erro ar nag do interruptor de fugas 3 Os bot es de funcionamento est o bloqueados 4 O ciclo de controlo tem uma falha Au idade funciona 1 Existe um obstaculo a frente do condensador durante uni bocado 2 O ciclo de controlo anormal f d bois na 3 A opera o de arrefecimento est seleccionada quando a tem e gepols para peratura ambiente no exterior se encontra acima dos 43 C 1 O filtro do ar est sujo ou bloqueado
41. E ni AN Pg MIN 2500 E E MIN 250 Length unitimm The height of installation for the indoor unit should be 2 5m above GREE_duct_eng_1022 indd 14 08 10 27 3 32 09 4 TT p Bo 11 Im Outdoor Unit Coogl Cc E 9 gt HSITSNA length unit mm tm ale e E Model GU X18JR 848 320 540 548 286 GU X24JR 913 378 680 548 340 GU X36JR 1032 412 1250 572 378 4 ERR MIN 1000 v MIN 500 MIN 500 on MIN 2000 biin 500 i MIN 2000 AE i E EE Se Precautions on installation of outdoor unit To ensure the unit in proper function selection of installation location must be in accordance with following principles Outdoor unit shall be installed so that the air discharged by outdoor unit will not return and that sufficient space for repair shall be provided around the machine The installation site must have good ventilation so that the outdoor unit can take in and exhaust enough air Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit If there is any obstacle blocking the air intake or exhaust remove it e Place of installation shall be strong enough to support the weight of outdoor unit and it shall be able to insulate noise and prevent vibration Ensure that the wind and noise from the unit will not affect your neighbors e Avoid direct sunshine over the unit It is better to set up a
42. O DA UNIDADE Instala o el ctrica Aten o Antes de instalar o equipamento el ctrico preste aten o aos seguintes pontos e Verifique se a alimenta o id ntica aos valores apresentados na placa das especifica es A capacidade da alimenta o tem de ser suficientemente forte e O cabo tem de ser instalado por pessoal profissional e Adapte linha da electricidade um interruptor de desligar com uma separa o de contacto de pelo menos 3 mm em todos os p los Use um cabo que n o seja mais leve do que o fio flex vel protegido de policloropreno designa o do c digo 60245 IEC 57 Liga o de um fio nico 1 Use um alicate de descarnar para retirar a camada de isolamento 25 mm de comprimento da extremidade do fio nico 2 Retire o parafuso do quadro do terminal da unidade de ar condicionado 3 Use um alicate para dobrar a extremidade do fio nico de modo a que seja formado um arco equivalente ao tamanho do parafuso 4 Passe o parafuso pelo arco do fio nico e fixe o arco no quadro do terminal Liga o de v rios fios enrolados 1 Use um alicate de descarnar para retirar a camada de isolamento 10 mm de comprimento da extremidade dos v rios fios enrolados 2 Retire o parafuso do quadro do terminal da unidade de ar condicionado 3 Use um alicate de dobra para ligar um terminal equivalente ao tamanho do parafuso na extremi dade dos v rios fios enrolados 4 Passe o parafuso pelo terminal dos
43. Pa ses fora da UE Se quiser eliminar este produto contacte as entidades locais e informe se sobre o m todo correcto para proceder sua elimina o Na Su a O equipamento el ctrico e electr nico aceite a t tulo gratuito em qualquer revendedor mesmo que n o tenha adquirido um novo produto Poder encontrar uma lista das esta es de recolha destes equipamentos na p gina da Web www swicho ch ou www sens ch B Informa es sobre a Elimina o de Produtos para Utilizadores Empresas 1 Na Uni o Europeia Se o produto for usado para fins comerciais e quiser elimin lo Contacte o seu revendedor SHARP que ir inform lo sobre a melhor forma de eliminar o produto Poder ter de pagar as despesas resultantes da recolha e reciclagem do produto Alguns produtos mais pequenos e em pequenas quantidades poder o ser recolhidos pelas esta es locais Na Espanha Contacte o sistema de recolhas p blico ou as entidades locais para mais informa es sobre a recolha de produtos usados 2 Em outros Pa ses fora da UE Se quiser eliminar este produto contacte as entidades locais e informe se sobre o m todo correcto para proceder sua elimina o A bateria fornecida com este produto cont m tra os de chumbo Para a Uni o Europeia o contentor de rodas tra ado significa que as baterias usadas n o dever o ser colocadas junto com o lixo dom stico Existe um sistema de separa o pr prio para baterias usadas para
44. XM SSS tu a GB X24JR GB X36JR t Ww mn u Mir gt L mt iN NNO N 08 10 27 3 32 08 INSTRUCTIONS OF UNIT INSTALLATION Installation dimensions Indoor unit GB X18JR A E G 5 I m rd e iS n mu 25 E F B C a Electric Box Liquid Pipe Gas Pipe LL D a DSSS TT T al Air Intake E i _ T G pt Q po f E Air Intake Drainage Pipe GB X24JR GB X36JR GB X24JR GB X36JR il h i Hb A A A E uma wo t Cc J L Cc D D E E Electric Box Air Intake sf E ling m i j C E a i Or UI ca Li p 1 i Drainage Pipe 7 Gas Pipe Liquid Pipe 1101 1011 GREE_duct_eng_1022 indd 13 Length unit mm Drainage Pipe Outer Diameter x E F G H J connecting Connecting ipe Pipe Liquid Pipe Gas Pipe Wall Thickness 08 10 27 3 32 09 4 ica Mo el INSTRUCTIONS OF UNIT INSTALLATION GB X18JR LH yy PREGA SALA f S S 17 E f Y 4 we 7 Nagano 4 Y Z LLA YL MIN 250 MIN 250 Sibi GB X24JR GB X36JR st Zz Nut with A Washer A VA MIN 250 Warning DESSES Nut Spring Washer ASSIS 220 LL LD LS LI 4 4 4 4 N x NN
45. a do sol melhor montar um protector contra o sol e O local da instala o dever conseguir drenar as guas da chuva e gua proveniente do descon gelamento do gelo Olocal da instala o dever impedir que a m quina sofra danos de queimaduras da neve ou que seja sujeita influ ncia do lixo ou fumo do leo e O local de instala o dever ser num local onde a sa da do ar n o fique virada para ventos for tes P 15 SANONLYOd TT p Bo 11 Im GREE_duct_por_1022 indd 15 dp 08 10 27 si ii cous Ho 11 01 INSTRU ES DE INSTALA O DA UNIDADE Instala o da unidade do interior Escolha do local de instala o e Certifique se de que a estrutura do gancho superior tem for a suficiente para suportar o peso da unidade O tubo de drenagem dever conseguir drenar facilmente a gua N o dever haver obst culos na entrada e sa da para manter o ar em boa circula o Certifique se que existe espa o necess rio para os trabalhos de instala o repara o e de ma nuten o Escolha um local afastado de uma fonte de calor g s inflam vel ou fumo A unidade montada no tecto criada para ser instalada no tecto A unidade do interior unidade do exterior fio da alimenta o e cabo de liga o dever o ser man tidos a pelo menos 1 metro da televis o ou r dio Isto serve para evitar interfer ncias na imagem e ru dos nesses aparelhos Instala o da unidade do interi
46. agrammi schematici e Il condizionatore d aria dovrebbe avere linee dell alimentazione speciali dotate di interruttori contro le perdite elettriche e interruttori in aria in modo da gestire eventuali condizioni di sovraccarico Il condizionatore deve essere dotato di messa a terra per evitare rischi provocati da guasti all isola mento dell unit In tutte le linee devono essere utilizzati terminali crimp o fili singoli Se si collegano fili multipli twistati alla morsettiera potrebbero formarsi degli archi Tutti i collegamenti di linea devono essere conformi al diagramma schematico delle linee Collega menti errati potrebbero provocare anomalie nel funzionamento o danni al condizionatore d aria e Evitate che cavi entrino in contatto con il tubo del fluido refrigerante il compressore e le parti mo bili come le ventole e Non modificate i collegamenti di linea interni all interno del condizionatore d aria Il produttore de clina qualsiasi responsabilit per eventuali perdite o funzionamento anomalo provocati da collega menti di linea errati Collegamento del cavo di alimentazione 1 Rimuovete il pannello anteriore dell unit esterna 2 Fate passare il cavo attraverso l anello in gomma 3 Collegate il cavo di alimentazione ai terminali L N e alla vite di messa a terra sul pannello elettrico in metallo 4 Fissate il cavo con un elemento di fissaggio del cavo Interruttore disgiuntore e cavo di alimentazione
47. alha da energia 02 sig E nifica que o estado de funcionamento ou o estado de Si desligar nao ser memorizado Prima o bot o ON OFF para guardar o valor definido e sair das configurag es ON OFF Quando a unidade desligada prima o bot o FAN e o bot o SLEEP em simult neo para activar o menu de depurar O LCD apresenta a mensagem DEBUG No modo de depurar prima o bot o MODE para ver 01 na rea da temperatura definida esquerda de DE BUG A rea OUT ENV do lado direito de DEBUG En apresenta o estado da configurag o si Prima o bot o A ou o bot o W para escolher a par ae tir das duas seguintes configurac es A temperatura da sala medida na entrada do ar a area OUT ENV apresenta 01 A temperatura da sala medida no controlador do fio a area OUT ENV apresenta 02 O sensor predefinido da temperatura da sala esta definido para a entrada do ar GREE_duct_por_1022 indd 7 dp 08 10 27 3 35 09 Apresentagao da falha e Quando existir uma falha no funcionamento da unida de a mensagem ERROR aparece a piscar no ecr do controlador do fio e o c digo de erro tamb m apresentado Quando houver varias falhas os c digos de erro sao apresentados uns a seguir ao outros no controlador do fio Os dois digitos indicam pormenori zadamente o c digo de erro As d
48. ando e la finestra di ricezione sul dispositi vo di controllo a filo Il telecomando pu inviare segnali fino ad una distanza di 8 metri Non fate cadere n lanciate volontariamente il telecomando Evitate che liquidi penetrino nel telecomando Evitate che il telecomando sia esposto alla luce diretta del sole Non collocate il telecomando in luoghi con temperature estremamente elevate Il tasto SWING non funziona con questa unit Tasto FAN Premete per impostare la velocit ventole SWING FAN Pe AUTOFAN ail crer AUTO i GG ed SWING ONVIIVLI Finestra del ricevitore Tasto TEMP Premete per impostare la temperatura TEMP adeguata Tasto MODE Premete per impostare MODE NONOEE la modalita di funziona mento ON OFF Premete per avviare o arresta re il funzionamento dell unit Installazione delle batterie e Dopo l installazione delle batterie sul display vengono visualizzate icone e sigle corrispondenti a tutte le funzioni e La durata delle batterie di circa 1 anno e Non utilizzate insieme batterie vecchie e nuove o diversi tipi di batterie e Se il telecomando non sar utilizzato per un periodo di tempo prolungato rimuovete le batterie per evitare perdite di liquido ed eventuali guasti Installate due batterie R03 AAA Accessori GREE_duct_ita_1022 indd 9 db 08 10 27 3 33 37 4
49. cando lesioni personali gravi o letali Non installate questa apparecchiatura in lavanderia PRECAUZIONI PER IL LUOGO DI MONTAGGIO INSTALLAZIONE e Assicuratevi di collegare il condizionatore d aria a una presa di corrente di voltaggio e frequenza adeguati L uso di una presa di corrente dal voltaggio e frequenza errati potrebbe provocare danni all unit con il conseguen te rischio di incendi Non installate l unit in un luogo che potrebbe essere soggetto a perdite di gas infiammabile Ci potrebbe provo care incendi Installate l unit in luoghi con quantit minime di polvere fumi o umidit nell aria Sistemate il tubo di drenaggio in modo tale da garantire un drenaggio corretto Un drenaggio insufficiente potrebbe far fuoriuscire acqua nella stanza bagnare i mobili ecc Assicuratevi di installare un interruttore differenziale o un interruttore disgiuntore a seconda del luogo d installazio ne per evitare scosse elettriche Prima dell uso controllate e assicuratevi che i cavi i tubi di drenaggio e le tubature siano collegati correttamente allo scopo di evitare eventuali rischi di perdite d acqua perdite di fluido refrigerante scosse elettriche o incendi Non collocate direttamente il condizionatore d aria in ambienti corrosivi con acqua o umidit Dopo l installazione elettrica il condizionatore d aria deve essere messo sotto tensione per verificare eventuali per dite elettriche questa operazione
50. capacity stated above is measured under nominal working conditions corresponding to standard external static pressure The parameters are subject to change with the improvement of products in which case the values on nameplate shall prevail E 25 GREE_duct_eng_1022 indd 25 T 08 10 27 i OT TT p Bo 11 Im Attenzione Il dispositivo contrassegnato da questo simbolo che segnala di non smaltire le apparecchiature elettriche ed elettroniche insieme ai normali rifiuti domestici Per tali prodotti previsto un sistema di raccolta a parte Pb GREE_duct_cov_1022 indd 3 A Informazioni sullo smaltimento per gli utenti privati 1 Nell Unione europea Attenzione Per smaltire il presente dispositivo non utilizzare il normale bidone della spazzatura Le apparecchiature elettriche ed elettroniche usate devono essere gestite a parte e in conformita alla legislazione che richiede il trattamento il recupero e il riciclaggio adeguato dei suddetti prodotti In seguito alle disposizioni attuate dagli Stati membri i privati residenti nella UE possono conferire gratuitamente le apparecchiature elettriche ed elettroniche usate a centri di raccolta designati In alcuni paesi anche il rivenditore locale pu ritirare gratuitamente il vecchio prodotto se l utente acquista un altro nuovo di tipologia simile Per maggiori informazioni si prega di contattare l autorit locale competente Se le apparecchiat
51. cata dalla stessa non torni indietro e in modo che vi sia spazio a sufficienza intorno all unit per eventuali riparazioni Il luogo di installazione deve avere una buona ventilazione in modo che l unit esterna possa aspirare e rilasciare aria a sufficienza Assicuratevi che non ci siano ostacoli per l entrata e l usci ta dell aria dall unit esterna Se sono presenti ostacoli che bloccano l entrata o l uscita dell aria rimuoveteli e Il luogo di installazione deve essere abbastanza solido da poter sostenere il peso dell unit ester na inoltre tale luogo deve avere propriet antivibrazioni e di isolamento dei rumori Assicuratevi che l aria e i rumori dall unit non disturbino i vicini e Evitate che l unit sia esposta alla luce diretta del sole Si consiglia di installare un pannello di ri parazione come protezione dal sole Il luogo di installazione deve garantire il drenaggio dell acqua piovana e scongelata Il luogo di installazione deve garantire che l unit non venga ricoperta dalla neve e non deve es sere esposto a nebulizzazione di olio o scarichi Il luogo di installazione deve essere un luogo nel quale l uscita dell aria di scarico non sia diretta verso forti venti I 15 GREE_duct_ita_1022 indd 15 dp 08 10 27 3 33 40 i cessa Mo IT m ISTRUZIONI PER L INSTALLAZIONE DELL UNIT Installazione dell unita interna Scelta del luogo di installaz
52. ce Condi o de funcionamento nominal e raio de funcionamento do ar condicionado il e DB C WB C DB ec WB C Arrefecimento nominal Aquecimento nominal 20 7 6 Arrefecimento minimo 21 15 18 fAquecimento maximo 27 24 w Aquecimento minimo 20 7 Nota e O design desta unidade encontra se em conformidade com os requerimentos da norma EN14511 e O volume do ar medido na press o est tica externa normal relevante A capacidade de arrefecimento aquecimento indicada acima medida em condi es nominais de funcionamento correspondentes press o est tica externa padr o Os par metros est o su jeitos a altera es com a melhoria dos produtos Nestes casos os valores na placa das especifi ca es prevalecem P 25 GREE duct por 1022 indd 25 dp 08 10 27 sui SHARP SHARP ELECTRONICS Europe GmbH SonninstraBe 3 D 20097 Hamburg SHARP CORPORATION 08LG 1 GREE_duct_cov_1022 indd 5 dp 08 10 27 sai
53. ciato del cavo Filo di controllo Filo di comunicazione SILA 7 4 LA 4 A i Ya i tubo metallico tubo metallico UY si n v AG Z fi Mme PU SA i dI BY IY hi AG iy f 4 4 7 A Z 3 IG 77 A 4 IG I F GY A IFZ 19 44 di IZ 9 NZ 7 7 A 1 23 4 Z j Figura 1 Figura 2 Diagramma schematico di installazione Installazione del Installazione del cavo superficiale cavo a scomparsa No Nome 1 Superficie della parete 2 Piastra inferiore del dispositivo di controllo a filo 3 Vite M4x10 4 Pannello del dispositivo di controllo a filo Attenzione La distanza di comunicazione tra la scheda madre ed il dispositivo di controllo a filo di 8 metri e Il dispositivo di controllo a filo non deve essere installato in un luogo nel quale sono presenti gocce d acqua o grandi quantit di vapore acqueo I 21 GREE_duct_ita_1022 indd 21 de 08 10 27 3 33 42 1 GREE_duct_ita_1022 indd 22 i 08 10 27 3 33 42 ISTRUZIONI PER L INSTALLAZIONE DELL UNIT Installazione elettrica Attenzione Prima di installare l apparecchiatura elettrica controllate quanto segue Controllate che l alimentazione corrisponda alla classe di efficienza indicata sulla targhetta La portata dell alimentazione deve essere sufficiente e Il cavo deve essere installato da personale qualificato e Installate un interruttore di disconnessione con una separazione d
54. common pipe shall be about 100mm lower than the drainage outlet of each set of unit A pipe with thicker wall shall be used for such purpose Thermal insulation materials of Drainage Pipe Drainage Pipeline Caution The joint of condensate pipe must not have leakage Testing of drainage system 1 After the electrical installation is completed carry out the testing of the drainage system 2 During the test check if the water correctly flows through the pipelines Carefully observe the joints to ensure that there is no leakage If the unit is to be installed in a new house carry out testing before decorating the ceiling Installation of refrigerant pipe Selection of refrigerant Pipe E GE ia a Liquid Pipe uom Unit and Outdoor For Extra Length of Pipe fe po po 120 g m Note e The standard pipe length is 5m If the pipe length exceed 5m add refrigerant As shown in above table e Use pipes with thickness 0 8mm 1 4 3 8 1 2 1 0mm 5 8 1 2mm 3 4 The pipe wall shall be able to withstand the pressure of 6 0 MPa e The longer the refrigerant pipe the lower the cooling effect and the heating effect E 18 nee o Connection of pipe 1 Align the flared end of the copper pipe with the center of the thread joint Manually tighten the flared end nut 2 Use torque wrench to tighten the flaring nut until the wrench clatters x M KR AL r Pipe for Indoor piang as pio
55. controlador do fio na parede usando os dois buracos Ligue o fio de controlo no painel de controlo Finalmente instale o painel do controlador do fio Aten o Durante a instala o da placa inferior do controlador do fio preste aten o direc o da placa infe rior O lado da placa com dois entalhes tem de ficar na posi o mais baixa caso contr rio o painel do controlador do fio n o pode ser instalado correctamente Cobertura da caixa el ctrica Esbo o para o fio de controlo da unidade interior Bra adeira do fio Fio de N NN IN ap a Y tubo met lico tubo met lico _ UY gt 17 17 AG 4 A 4 WZ 47 TG 4 Al le LA 6 8 d 7 bi A Y Z e hi 4 by Z DI OY 44 lt 4 a i IA A D VW D Y A 2 Z A MEZ DIY 3 Z GG HG o Z 1 2 3 4 Z j 7 Imagem 1 Imagem 2 Diagrama esquem tico de instala o Montagem su Montagem dissi perf cie do cabo mulada do cabo N Nome Superf cie da parede Placa inferior do controlador do fio Parafuso M4x10 Painel do controlador do fio 1 2 3 4 Atengao e Adistancia de comunica o entre o quadro da distribui o e o controlador do fio de 8 metros O controlador do fio n o dever ser instalado num local onde haja pingos de agua ou uma grande quantidade de vapor de gua P 21 SANONLYOd GREE_duct_por_1022 indd 21 dp 08 10 27 sui i cessa B Go una INSTRU ES DE INSTALA
56. dade no interior 2 Puxe o cabo do final do controlador do fio atrav s do anel de borracha 3 Ligue a linha do sinal do controlador do fio a uma tomada de pinos de 4 bits no quadro do circuito da unidade no interior CN10 do controlador do fio liga se a CN3 da unidade no interior 4 Fixe o cabo do sinal do controlador do fio com um fixador de cabos Disjuntor diferencial e Coloque um disjuntor diferencial de modo a proteger se contra choques el ctricos no caso de derrames e Use um disjuntor activado por corrente de alta sensibilidade e alta velocidade com uma corrente de sensibilidade nominal abaixo dos 30 mA e um tempo de funcionamento abaixo dos 0 1 segundos Requerimentos de liga o terra e N o se esque a de ligar o ar condicionado terra N o ligue o fio de liga o terra ao tubo do g s da gua p ra raios ou fio de liga o terra do telefone Uma liga o incompleta terra pode dar origem a choques el ctricos e O fio de duas cores amarelo e verde do ar condicionado o fio de liga o terra e n o pode ser usado com outros intuitos N o pode ser cortado e ser fixado com um parafuso caso contr rio pode dar origem a choques el ctricos SININLdOd Diagrama de liga o do cabo da unidade A rea da sec o dos cabos seleccionada pelos utilizadores n o pode ser mais pequena do que as especifica es apresentadas no diagrama Diagrama esquem tico da liga o da linha da unidade GB X1
57. de bor racha Ate a sa da bloqueada com cordel para evitar fugas e use tamb m materiais de isolamento t rmico para embrulhar a sa da bloqueada e oe saem da fabrica ambas as saidas de drenagem v m bloqueadas com tamp es de borra cha Quando ligar o tubo de drenagem a unidade nao aplique forga excessiva na tubagem na parte lateral da unidade A posig o de fixag o da tubagem dever ser perto da unidade Compre tubos em PVC de utiliza o geral numa loja perto de si para usar como tubagem de drenagem Quando efectuar a ligagao coloque a extremidade da tubagem em PVC no orificio de drenagem Use tubos de drenagem flexiveis e aperte os com um lago Nunca use fita adesiva para ligar o orificio de drenagem e o tubo de drenagem flexivel Quando o tubo de drenagem colocado for usado para varias unidades o tubo comum dever es tar 100 mm abaixo da saida de drenagem de cada unidade Para isso pode usar um tubo com uma estrutura mais grossa Materiais de isolamento t rmico do tubo de drenagem Tubagem de drenagem Aten o A junta do tubo de condensa o n o pode ter fugas Teste do sistema de drenagem 1 Ap s ter completado a instala o el ctrica efectue o teste do sistema de drenagem 2 Durante o teste verifique se a gua corre correctamente ao longo dos tubos Observe cuidadosa mente as juntas para se assegurar de que n o existem fugas Se a unidade for instalada numa casa nova efectue o teste antes de decora
58. deve essere eseguita da personale qualificato Nel cablaggio fisso necessario collegare un interruttore di disconnessione per tutti i poli con una separazione di contatto di almeno 3 mm in tutti i poli La temperatura del circuito del fluido refrigerante elevata assicuratevi che il cavo di interconnessione non entri in contatto con il tubo in rame l 2 GREE_duct_ita_1022 indd 2 de 08 10 27 3 33 34 4 FUNZIONAMENTO DEL DISPOSITIVO DI CONTROLLO A FILO AVVERTENZA Non installate il dispositivo di controllo a filo in luoghi nei quali ci sono perdite d acqua e Evitate di urtare lanciare gettare o aprire molto spesso il dispositivo di controllo a filo TIMER 1101 NN ERROR ONOFF LULL I HR AUTO EN 2 FAN W h SPEED SLEEP SAVE SET pes OUT ENV DOT eo DT III rest Sl AUTO COOL DRY FAN HEAT ONVITVLI d NANN Display TIMER Display velocit ventole Auto Alta Media Bassa Display DEFROST Display SAVE Display di impostazione della temperatura Display della temperatura ambiente Display della modalit raffreddamento deumidificazione ventole riscaldamento automatica Display dei guasti Display SLEEP Tasto MODE Tasto di impostazione della temperatura per aumento della temperatura Tasto di impostazione della temperatura per riduzione della temperatura Tasto FAN Tasto SLEEP controllo esterno della tempera
59. do l quido refrigerante e a junta com uma esponja depois prenda a esponja com fita de pl stico Remo o do ar 1 Retire ambos os tamp es do veio da v lvula das v lvulas de paragem 2 Retire o tamp o da porta de servi o da v lvula de paragem do lado do g s 3 Ligue a mangueira do man metro de admiss o porta de servi o e bomba de v cuo Certifique se de que a extremidade da mangueira a ser ligada porta de servi o tem um impul sor do centro da v lvula Abra a v lvula do man metro de admiss o e utilize a bomba de v cuo durante 10 a 15 minutos Certifique se de que o monovacu metro apresenta uma leitura de 76 cmHg Feche a v lvula do man metro de admiss o Desligue a bomba de v cuo Abra por completo a v lvula de paragem do lado do l quido com a chave sextavada diagonal mente 4 mm Rode completamente para cima at haver contacto 8 Abra por completo a v lvula de paragem do lado do g s com a chave sextavada Rode comple tamente para cima at haver contacto 9 Desligue a mangueira do man metro de admiss o da porta de servi o 10 Volte a colocar o tamp o da porta de servi o e ambos os tamp es do veio da v lvula bem aperta dos Notas e Use um man metro de admiss o e mangueiras exclusivas para o R410A e Ap s a remo o do ar verifique as liga es dos tubos quanto a fugas de g s usando um detector de fugas ou usando gua com detergente Em rela o ao detector de fugas us
60. e controller could not be disassembled and the control wire be used for the wire controller should not be changed by users optionally the installation and maintenance should be carried out by the professional personnel 2 Select an installation position According to the size of the control wire of the wire controller leave a recess or a embedded wire hole to bury the control wire 3 Ifthe control wire between the wire controller and the indoor unit is surface mounted use 1 metallic pipe and make matching recess in the wall Refer to Figure 1 If concealed installation is adopted 1 metallic pipe can be used Refer to Figure 2 4 No matter if surface mounting or concealed mounting is selected it is required to drill 2 holes in the same level which distance shall be the same as the distance 60mm of installation holes in the bottom plate of the wire controller Then insert a wood plug into each hole Fix the bottom plate of the wire controller to the wall by using the two holes Plug the control wire onto the control panel Lastly install the panel of the wire controller HSITSNA Caution During the installation of the bottom plate of the wire controller pay attention to the direction of the bottom plate The plate s side with two notches must be at the lower position and otherwise the panel of the wire controller cannot be correctly installed Electric box cover Sketch map for indoor unit N
61. e status it is Condensate Drainpipe required to set up a backwater elbow The requirements is Ss A B2P 10 20 mm lt P is the absolute pressure inside the m unit The unit of the pressure is Pa Installation of rectangular air pipe Name Hanger Air Intake Pipe Canvas Air Pipe Air Intake Filter Main Air Supply Pipe Air Supply Outlet APS Air Intake AA 3 Air Supply AL NA LA Cautions GREE duct eng 1022 indd 17 q 08 10 27 a The air supply pipe and the air intake pipe must be covered with a layer of thermal insulation so as to avoid thermal leakage and condensation Firstly apply liquid nail on the pipes then attach the thermal insulation cotton with a layer of tinfoil Use the liquid nail cover to fix it Lastly use tinfoil adhesive tape to carefully seal the joints other good thermal insulation materials can also be used The air supply pipes and the air intake pipes shall be fixed to the prefabricated boards of the ceiling by using iron supports The joints of the pipes must be sealed by glue so as to avoid leakage The design and installation of air pipes must be in conformity with the relevant state engineering criteria The edge of the air intake pipe must be at least 150mm away from the wall The air intake must be covered with filter Silencing and shock absorption shall be considered in the design and installation of the air pipes Additionally the noise source must be
62. e um tipo de alta sensibilidade criado especialmente para o R410A SINONLYOd NODO gt UNIDADE NO INTERIOR Man metro de admiss o V lvula de paragem do lado do g s Monovacu metro V lvula de paragem do lado do l quido Chave para parafuso Completamente abert G 4 7 sextavado N 4 Abrir ta Completa gt 3 Ligar 5 Fechar mente aberto i Tampao x Desligar D Remover Remover Tamp o A Substituir Substituir NQ IS Adaptador da bomba de vacuo Tamp o da porta de servi o g Remover CD Bomba de v cuo Substituir P Operar Corte GREE_duct_por_1022 indd 19 dp 08 10 27 sani ii cous o 11 01 INSTRU ES DE INSTALA O DA UNIDADE At en o Quando ligar a unidade do interior com o tubo do refrigerante n o puxe as juntas grande e peque na da unidade do interior com for a para prevenir danos ou derrames da ac o capilar da unidade do interior e dos outros tubos O tubo do refrigerante dever ser suportado pelo devido suporte A altura do tubo n o dever ex ceder a altura da unidade Instala o da camada protectora do tubo do refrigerante 1 Para evitar a gera o de condensa o do tubo do refrigerante e evitar fugas o tubo do refrigeran te tem de ser coberto com materiais de isolamento t rmico atados com fita adesiva e isolados do ar Ajunta a ligar a unidade
63. ed for a long time take out the batteries to avoid liquid leakage and any subsequent failure e Load two ROS AAA batteries Accessories GREE_duct_eng_1022 indd 9 dp 08 10 27 3 32 07 ii se p Bo 11 Im REMOTE CONTROLLER OPERATION COOL mode operation 1 Press the ON OFF button FR 2 Press the MODE button to select AUTOFAN per COOL mode EIG 3 Press the Temperature button to set the desired temperature MODE ON OFF il HEAT mode operation 1 Press the ON OFF button Sm 2 Press the MODE button to select AUTOFAN OPER H EAT mode a 20 3 Press the Temperature button to set desired temperature In the heating mode the unit has the functions of preventing cold air supply and supplying remaining heat After the startup of the compressor the indoor fan shall start operation when the evaporator temperature is high or equals 35 C or after the unit has be started for 45 seconds so as to prevent cold air flow blowing out of the unit After the stop of the compressor the indoor fan will rotate for 120 seconds GREE_duct_eng_1022 indd 10 dp 08 10 27 sui DRY mode operation 1 Press the ON OFF button CO SIE Em 2 Press the MODE button to select DRY AUTOFAN OPER td y mode S 25 3 Press the Temperature button to set
64. ed rotation of internal fans Ground the air conditioner without fail Do not connect the grounding wire to gas pipe water pipe lightning rod or telephone grounding wire Incomplete grounding may cause electric shock 6 If anything is abnormal with the air conditioner ex a burning smell stop the operation immediately and turn the circuit breaker OFF 7 The appliance shall be installed in accordance with national wiring regulations Improper cable connection can cause the power supply cord plug and the electrical outlet to overheat and cause fire 8 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Use only the manufacture specified power cord for replacement CAUTIONS FOR USE 1 Open a window or door periodically to ventilate the room especially when using gas appliances Insufficient ventilation may cause oxygen shortage Do not operate the buttons with wet hand It may cause electric shock For safety turn the circuit breaker off when not using the unit for an extended period of time Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly in place Do not put anything on the outdoor unit nor step on it The object or the person may fall down or drop causing injury This unit is designed for residential use Do not use for other applications such as in a kennel or greenhouse to raise animals or grow plan
65. efinig es dos c digos de erro sao as seguintes C digo Falha de erro EO Falha da bomba E1 Protec o da alta press o do compressor E2 Protec o contra o gelo no interior E3 Protec o da baixa press o do compressor E4 Protec o da alta temperatura de descarga do compressor E5 Protec o do sobreaquecimento do compressor e condu o do inversor E6 Falha de comunica o E8 Protec o da ventoinha no interior E9 Protec o completa contra gua FF Falha de comunica o do controlo ligado FO Falha do sensor da sala no interior na entrada do ar F1 Falha do sensor da temperatura de evaporag o F2 Falha do sensor da temperatura de condensag o Falha do sensor da temperatura no exterior Falha do sensor da temperatura de condensa o Falha do sensor da sala no interior no controlador do fio Os bot es est o bloqueados nao se trata de uma falha e E5 O mau funcionamento do material ser apresentado pela luz do indicador na placa mae da unidade exterior GREE_duct_por_1022 indd 8 sp 08 10 27 3 35 09 OPERA O DO COMANDO A DIST NCIA Precauc es e Aponte o comando a distancia para a janela do receptor no controlador do fio e prima o bo tao desejado e Certifique se de que n o existem obst culos entre o comando dist ncia e a janela do re ceptor do controlador do fio e O comando dist ncia pode enviar sinai
66. etico Dopo aver scollegato l unit dall alimentazione l impostazione SAVE sar memorizzata L impostazione sar di nuovo valida quando l unit verr collegata nuovamente all alimen tazione Impostando la modalit SAVE la modalit di attesa e la modalit automatica sa ranno disabilitate GREE_duct_ita_1022 indd 6 o 08 10 27 3 33 36 Visualizzazione della temperatura esterna e In normali condizioni vengono visualizzati ENV e la temperatura ambiente Premete il tasto SLEEP per 5 secondi Sul display LCD sar visualizzato OUT ENV La temperatura esterna viene visualizzata sul display per 10 secondi quindi viene nuovamente vi ETEW s sualizzata la temperatura ambiente BE SLEEP TIMER ON OFF ONVITVLI Impostazione della funzione di memoria Quando l unit spenta premete il tasto MODE per Es 10 secondi per commutare i valori impostati in modo da decidere se lo stato di funzionamento dell unit o lo A stato di spegnimento dell unit devono essere memo E rizzati dopo una caduta di corrente 56 Se nell area della temperatura impostata visualizza to 01 lo stato di funzionamento dell unit o lo stato di spegnimento dell unita devono essere memorizzati E dopo una caduta di corrente se visualizzato 02 lo Si stato di funzionamento dell unit o lo stato di spegni mento dell unit
67. extremidade do fio de controlo do controlador do fio ligada ao quadro da caixa el ctrica da unidade interior devendo ser apertada com uma bragadeira do fio A outra extremidade devera ser ligada com o controlador do fio conforme esbogo apresentado abaixo O fio de controlo usado para a unidade interior e controlador do fio que um fio de controlo especial com 8 metros o material a ser adoptado para o fio de controlo dever ser de uma subst ncia met lica O con trolador do fio nao pode ser desmontado e o fio de controlo a ser usado para o controlador do fio nao dever ser alterado opcionalmente pelos utilizadores A instalag o e manuteng o devera ser efectuada por pessoal profissional 2 Escolha uma posi o de instala o De acordo com o tamanho do fio de controlo do controlador do fio deixe um recanto ou um orif cio para o esconder 3 Se o fio de controlo entre o controlador do fio e a unidade interior estiver montado na superf cie use o tubo met lico 1 e fa a um recanto para este na parede consulte a Imagem 1 Se for adoptada uma instala o oculta pode usar o tubo met lico 1 consulte a Imagem 2 4 Quer fa a a montagem na superf cie quer fa a uma montagem oculta precisa de fazer 2 buracos ao mesmo n vel em que a dist ncia ser a mesma que a dist ncia 60 mm entre os buracos de instala o na placa inferior do controlador do fio A seguir insira uma bucha de madeira em cada buraco Fixe a placa inferior do
68. f this product please contact your local authorities and ask for the correct method of disposal The battery supplied with this product contains traces of Lead For EU The crossed out wheeled bin implies that used batteries should not be put to the general household waste There is a separate collection system for used batteries to allow proper treatment and recycling in accordance with legislation Please contact your local authority for details on the collection and recycling schemes For Switzerland The used battery is to be returned to the selling point For other non EU countries Please contact your local authority for correct method of disposal of the used battery EN 08 10 27 3 30 14 CONTENTS Operating Instructions mportant safety INSAPTUGHONS anne E 2 e Wire controller operation ii E 3 COD OT RNA RR Rn e PR UE PR DOR RE E 4 Fan Control E A AE E A ET E 4 Temperature Setting ac sad E 4 Sleep function Selling u E 5 Operating mode selling E 5 Timer selig een E 6 SAVE Setting GRA RO RI E 6 Display of outdoor temperature ii E 7 MEMONIUNCUO NS Ozieri E 7 Room temperature sensor setting 4 E 7 Falle displasia E 8 e Remote Controller operation treneren E 9 L ading Batteries aliante E 9 Cool mode operation nn E 10 Heat mode operation erre
69. far away from where people stay The air intake shall not be located above the place where users stay offices and rest places etc E 17 GREE_duct_eng_1022 indd 18 dp 08 10 27 Hi UNIT INSTALLATION INSTRUCTIONS Installation of drainage pipeline The Drainage Pipeline shall be installed with an inclining angle of 5 10 so as to facilitate the drainage of condensate The joints of the Drainage Pipeline must be covered by thermal insulation materials to avoid generation of exterior condensate A Drainage outlet is located at both the left and right sides of the indoor unit After selecting one Drainage outlet the other outlet shall be blocked by rubber plug Bundle the blocked outlet with string to avoid leakage and also use thermal insulation materials to wrap the blocked outlet When shipped out from factory both the Drainage outlets are blocked by rubber plugs When connecting the drainage pipe with the unit do not apply excessive force to the pipeline at the side of the unit The fixing position of the pipeline shall be near the unit Purchase general purpose hard PVC pipe locally to be used as the drainage pipeline When carrying out connection place the end of the PVC pipeline into the drainage hole Use flexible drainage tube and tighten it with thread loop Never use adhesive to connect the drainage hole and the flexible drainage tube When the laid drainage pipe is used for multiple units the
70. gt j Screw gt Hanger 4 3 Install the indoor unit to the ceiling Screw A a _ Hanger 5 L Yi y g 7 EN Nut i TR f 5 i N Air Intake N lt Air Supply DA ef TR 3 I Enlargement Precautions for unfavorable installation The preparation of all pipes connecting pipes and drainage pipes and cables connecting lines of wire controller indoor unit and outdoor unit must be ready before the installation so as to achieve smooth installation Drill an opening on the ceiling Maybe it is required to support the ceiling to ensure the evenness of it and avoid the vibration of it Consult with the user or a construction company for details In case the strength of ceiling is not enough use angle iron sections to set up a beam support Place the unit at the beam and fix it E 16 GREE_duct_eng_1022 indd 16 T 08 10 27 sai Check of the indoor unit level After the indoor unit is installed be sure to check the level of the whole unit The unit must be placed horizontally but the condensate pipe shall be installed obliquely so as to facilitate the drainage of condensate Level gauge JJJ JIII III API PF m SP LLP LDL LL Af HS Mf GF FOF HK I CALLA ll LOLOL LLL 5 i T Do Airintake E Air Supply Condensate E E Drainpipe m p Ss Op lt gt US uu lt i o 2 m A Enlarged View As the inside of the unit is in the adn negative pressur
71. ha o cuidado de n o expor o seu corpo directamente na sa da de ar durante um longo per odo de tempo Pode afectar a sua condi o f sica 3 Quando usar o ar condicionado com beb s crian as idosos acamados ou deficientes certifique se de que a tem peratura da sala a adequada 4 Nunca insira objectos dentro da unidade A introdu o de objectos poder resultar em ferimentos devidos eleva da velocidade de rota o das ventoinhas interiores 5 N o se esque a de ligar o ar condicionado terra N o ligue o fio de liga o terra ao tubo do g s da gua p ra raios ou fio de liga o terra do telefone Uma liga o incompleta terra pode dar origem a choques el ctricos 6 Se ocorrer algo de anormal com o ar condicionado por ex um cheiro a queimado pare imediatamente o seu fun cionamento e DESLIGUE o disjuntor 7 O aparelho deve ser instalado de acordo com as regula es nacionais de liga o Uma liga o inadequada do cabo pode sobreaquecer o fio da alimenta o ficha e tomada e dar origem a um inc ndio 8 Se o fio da alimenta o ficar danificado tem de ser substitu do pelo fabricante pelo seu agente de repara o ou por uma pessoa igualmente qualificada de modo a evitar perigos Use apenas o fio da alimenta o especificado pelo fabricante para proceder substitui o CUIDADOS DE UTILIZA O 1 Abra uma janela ou porta periodicamente para ventilar a sala especialmente quando usar aparelhos a
72. i contatto di almeno 3 mm su tutti i poli sulla linea di alimentazione elettrica e Utilizzate un cavo non pi leggero di un cavo flessibile schermato in policloroprene codice 60245 IEC 57 Collegamento di un filo singolo 1 Utilizzate uno spellafili per spellare lo strato di isolamento lungo 25 mm dall estremit del filo sin olo 2 Rimuovete la vite dalla morsettiera del condizionatore d aria 3 Utilizzate delle pinze per piegare l estremit del filo singolo in modo da formare un anello corri spondente alle dimensioni della vite 4 Inserite la vite attraverso l anello del filo singolo e fissate l anello alla morsettiera Collegamento di fili multipli twistati 1 mie uno spellafili per spellare lo strato di isolamento lungo 10 mm dall estremit dei fili multi pli twistati 2 Rimuovete la vite dalla morsettiera del condizionatore d aria 3 Utilizzate pinze a crimpare per collegare un terminale che corrisponda alle dimensioni della vite all estremit dei fili multipli twistati 4 Inserite la vite attraverso il terminale dei fili multipli twistati e fissate il terminale alla morsettiera Avvertenza Se la linea flessibile di alimentazione o la linea del segnale dell apparecchiatura sono danneggiate utilizzate esclusivamente speciali linee flessibili per la sostituzione Prima di collegare le linee leggete i voltaggi dei relativi componenti sulla targhetta Eseguite quindi i collegamenti delle linee in base ai di
73. i controllo a filo due numeri in dicano il codice d errore dettagliato Le definizioni dei codici d errore sono le seguenti Codice Guasto d errore EO Guasto pompa E1 Protezione compressore da alta pressione E2 Protezione interna antigelo E3 Protezione compressore da bassa pressione E4 Protezione uscita compressore da temperature elevate E5 Protezione compressore da surriscaldamento e trasmissione invertitore E6 Errore di comunicazione E8 Protezione ventola interna E9 Protezione completa acqua FF Errore di comunicazione del controllo collegato FO Guasto del sensore interno nell entrata dell aria F1 Guasto del sensore della temperatura di evaporazione F2 Guasto del sensore della temperatura del condensatore Guasto del sensore esterno Guasto del sensore della temperatura di scarico Guasto del sensore interno nel dispositivo di controllo a filo tasti sono bloccati non si tratta di un guasto e E5 il malfunzionamento dei materiali indicato dalla spia dell indicatore sulla scheda madre dell unit esterna GREE_duct_ita_1022 indd 8 T 08 10 27 3 33 37 OT TT p a i FUNZIONAMENTO DEL TELECOMANDO Precauzioni e Puntate il telecomando verso la finestra di ricezione del dispositivo di controllo a filo e preme te il tasto desiderato e Assicuratevi che non vi siano ostacoli tra il telecom
74. ia e baixa 08 10 27 3 35 11 4 i cessa p Mo el FUNCAO DA UNIDADE 1 Montagem dos dois sensores da tem peratura da sala Esta s rie de unidades de ar condicio nado canalizadas tem dois sensores de temperatura da sala Um encontra se na entrada do ar da unidade do interior e o outro encontra se dentro do controlador do fio O utilizador pode seleccionar um dos dois sensores da temperatura da sala de acor do com os requerimentos de engenharia consulte a sec o das instru es do controlador do fio para obter informa es detalhadas acerca do funcionamento o sensor predefinido da temperatura da sala o que se encontra na entrada do ar 2 Verifica o da temperatura no exterior A temperatura no exterior pode ser veri ficada no controlador do fio consulte a sec o das instru es do controlador do fio para obter informa es detalhadas acerca do funcionamento 3 A altura geom trica de retorno da bomba de drenagem de condensa o pode atingir 1 1 m de modo a que a instala o de engenharia seja muito conveniente e r pida A altura geom trica de retorno da bomba de 1 100 mm GREE_duct_por_1022 indd 12 Sy VA Lado exterior J Sensor exterior A 4 2 1 4 4 4 7 H 4 Sem i Bomba SAAS AS JIS ISSA ALLA im Sensor A da temperatura da sala Sensor B da temperatura da sala LIL RUM A Lado interior
75. identificare eventuali perdite di gas utilizzando un rivelatore di perdite o acqua e sapone Se utilizzate un rivelatore di perdite utilizzate un tipo ad alta sensibilit progettato appositamente per R410A gt gt z fe NOOO A H UNIT INTERNA Collettore del calibro Calibro composto Valvola di arresto Valvola di arresto lato fluido lato gas Chiave per vite a testa esagonale Aprite completamente gt Aprite N ji Aprite com gt Collegate gt Chiudete pletamente Tappo Scollegate D Rimuovete panies OL Tappo Sostituite O Sostituite NQ s Adattatore per 1 pompa a vuoto Tappo sportello O di servizio 2 Rimuovete C gt Pompa a vuoto Sostituite P 4 Azionate Spegnete GREE_duct_ita_1022 indd 19 de 08 10 27 3 33 41 4 ii cous CRER 11 01 ISTRUZIONI PER L INSTALLAZIONE DELL UNIT Caution Quando collegate l unit interna con il tubo del fluido refrigerante non tirate con forza eccessiva i giunti piccoli e grandi dell unit interna in modo da evitare che il capillare dell unit interna e altri tubi si rompano e presentino perdite e Il tubo del fluido refrigerante deve essere sostenuto da una staffa adeguata Il peso del tubo non deve essere sostenuto dall unit Installazione di uno strato protettivo sul tubo del fluido refrigerante 1 Pe
76. iente pode deixar a sala e a mob lia h mida Certifique se que instala um disjuntor ou um interruptor diferencial dependendo do local da instala o para evitar choques el ctricos Antes da utiliza o verifique e certifique se que os cabos tubos de drenagem e condutas est o devidamente liga dos para eliminar o risco de fugas de gua fugas de refrigerante choque el ctrico ou fogo A favor n o exponha a unidade de ar condicionado directamente a um ambiente corrosivo com gua ou humida e Ap s a instala o el ctrica a unidade de ar condicionado dever ser ligada para efectuar um teste de fugas el c tricas Teste efectuado por um profissional Dever ligar um interruptor de corte de todos os p los com uma separa o do contacto de pelo menos 3 mm em todos os p los cablagem fixa Atemperatura do circuito refrigerante ser elevada Mantenha o cabo de interliga o afastado do tubo de cobre P 2 GREE_duct_por_1022 indd 2 dp 08 10 27 3 35 06 See o o 11 01 OPERA O DO CONTROLADOR DO FIO AVISO e Nunca instale o controlador do fio num local onde haja fugas de agua Evite bater atirar lan ar ou abrir frequentemente o controlador do fio TIMER III N ERROR ONOFF III Lt HR E SPEED W SLEEP SAVE SET OUT ENV DD Ty A m D a II TEST N AUTO COOL DRY FAN HEAT SINONLYOd d OOO PPPA Apre
77. il tubo del fluido refrigerante e il giunto con della spugna quindi fissate la spugna con del nastro in plastica Rimozione dell aria Rimuovete entrambi i tappi degli assi delle valvole dalle valvole d arresto 2 Rimuovete il tappo dello sportello di servizio dalla valvola di arresto lato gas 3 Collegate il tubo del collettore del calibro allo sportello di servizio e alla pompa a vuoto Assicuratevi che l estremit del tubo collegata allo sportello di servizio sia dotata di uno spingitore per spilli Aprite la valvola del collettore del calibro e azionate la pompa a vuoto per 10 15 minuti Assicuratevi che il calibro composto indichi 76 cmHg Chiudete la valvola del collettore del calibro Spegnete la pompa a vuoto Aprite completamente la valvola d arresto lato fluido utilizzando la chiave per viti a testa esago nale diagonalmente 4 mm Ruotate completamente verso l alto per eseguire il contatto 8 Aprite completamente la valvola d arresto lato gas utilizzando la chiave per viti a testa esagona le Ruotate completamente verso l alto per eseguire il contatto 9 Scollegate il tubo del connettore del calibro dallo sportello di servizio 10 Ricollocate saldamente in posizione il tappo dello sportello di servizio ed entrambi i tappi degli assi delle valvole Nota e Utilizzate un collettore del calibro e tubi progettati appositamente per R410A e Dopo la rimozione dell aria verificate i collegamenti dei tubi per
78. ione dell unit Il tubo di drenaggio deve poter drenare facilmen buona circolazione dell aria Assicuratevi che ci sia spazio a sufficienza per tenzione collocati ad almeno 1 m da televisori o radio Ci gini o rumori nelle suddette apparecchiature Installazione dell unit interna 1 Inserite un bullone a espansione M10 nel foro Perforate il bullone con il chiodo di ferro Fate riferimento al disegno con le dimensioni del profilo dell unit interna per informazioni sulla distanza tra i fori 2 Installate la sospensione per l unit interna 3 Installate l unit interna al soffitto Entrata dell aria Precauzioni per l installazione La preparazione di tutti i tubi tubi di collegamen to del dispositivo di controllo a filo unit interna Assicuratevi che il telaio superiore della sospensione sia abbastanza solido da sostenere il peso te l acqua Non devono esserci ostacoli in corrispondenza dell entrata e dell uscita in modo da garantire una gli interventi di installazione riparazione e manu Scegliete un luogo lontano da fonti di calore gas infiammabili o fumo L unit installata al soffitto installazione a scomparsa al soffitto L unit interna l unit esterna il cavo di alimentazione e il cavo di collegamento devono essere consente di prevenire interferenze con le imma EA 1 ee DANA Vit Condizionatore d aria ite per amp l installazione lt So
79. ire o painel dianteiro da unidade do exterior 2 Passe o cabo pelo anel de borracha 3 Ligue o cabo da alimenta o aos terminais L N e ao parafuso de liga o terra na caixa el ctri ca de metal 4 Fixe o cabo com o fixador de cabos Corta circuito e cabo da alimenta o recomendado Modelo Alimenta o Corta circuito rea seccional cruzada minima do cabo da alimenta o GB X18JR GuxtgR ONO on Tr dem GB X24JR 6A 1 0 mm GB XSBJR 1590 240 V 50 Hz Dun GU X36JR 25A e Se o cabo da alimenta o for mais comprido do que 15 metros aumente adequadamente a sec o cruzada do cabo da alimenta o de modo a evitar acidentes devido a sobrecargas P 22 GREE_duct_por_1022 indd 22 de 08 10 27 sui TT p Bo 11 Im GREE_duct_por_1022 indd 23 dp 08 10 27 sui Atengao Tenha muito cuidado quando efectuar as seguintes liga es para evitar o mau funcionamento do ar condicionado devido interfer ncia electromagn tica Alinha do sinal do controlador do fio tem de ser separada da linha da alimenta o e a linha de liga o entre a unidade no interior e a unidade no exterior Caso a unidade seja instalada num local vulner vel a interfer ncias electromagn ticas prefer vel usar um cabo protegido ou um cabo duplo entrela ado como linha de sinal do controlador do fio Liga o da linha do sinal do controlador do fio 1 Abra a cobertura da caixa el ctrica da uni
80. it di raffredda mento e deumidificazione quindi passate all impostazione SAVE per la modalit di riscal damento Saranno visualizzati SAVE e HEAT Dopo aver completato l impostazione premete contemporaneamente il tasto FAN ed il tasto W per 5 secondi per chiudere l impostazione SAVE Dopo aver attivato l interfaccia di impostazione SAVE il sistema chiude l interfaccia se non viene eseguita alcuna operazione entro 20 secondi dall ultima pressione di un tasto sar visualizzata la normale interfaccia di spegnimento Dopo aver completato le impostazioni di cui sopra il sistema visualizza SAVE La temperatura im postata non superer la gamma di temperature dell impostazione SAVE Ad esempio se il limite di raffreddamento minimo impostato a 23 C e il limite di raffreddamento mas simo impostato a 27 C la temperatura di raffreddamento pu essere selezionata solo all interno della gamma compresa tra 23 e 27 C utilizzando il telecomando o il dispositivo di controllo a filo Se il limite massimo della temperatura uguale al limite minimo il siste ma in grado di funzionare solo a questa temperatura nella modalit corrispondente Per chiudere l impostazione SAVE premete contemporaneamente il tasto FAN ed il tasto Y per 5 secondi quando l unit spenta Il valore impostato in precedenza non sar cancellato e sar impostato come temperatura iniziale per l impostazione successiva di risparmio energ
81. itioning unit after the unit is shut off and the power supply is disconnected Otherwise electrical shock or injury may be caused Do not use water to clean the air conditioner Otherwise there may be electrical shock Use a steady stepping stand HSITSNA Maintenance at the beginning of operating season If there is any abnormal condition ask after sales personnel to offer guidance e Check the air inlet and outlet of the indoor and outdoor units to confirm there is no blockage Check if the grounding wire is in good condition Operating by the professional Check if the line connection is in good condition Operating by the professional e Check if there is any word displaying on the LCD of the wire controller after connecting the unit to power supply Maintenance at the end of the operational season When the weather is clear operate the unit in fan mode for half a day so as to dry the inside of the unit When the air conditioner is not used for a long time cut off the power supply The words on the LCD of the wire controller will disappear Appendix Air conditioner nominal working condition and working range Test condition Indoor side Outdoor side 20 ae 7 Nominal cooling Nominal heating Note The design of this unit conforms to the requirements of EN14511 standard The air volume is measured at the relevant standard external static pressure Cooling heating
82. iva Tubo di drenaggio necessario installare una curva della condensa di rigurgito gt I requisiti sono i seguenti lt A B2P 10 20 mm m P indica la pressione assoluta 4 all interno dell unit Lunita della pressione Pa Installazione del tubo rettangolare dell aria ri m Sospensione Tubo di entrata dell aria 3 Tubo dell aria Installazione al soffitto 4 Entrata dell aria N 2 5 Filtro pd E Entrata E Ali tazi Tubo di alimentazione E rate x imentazione di alime Of 4 4 dellaria N 4 dell aria 6 dell aria principale Z 7 Uscita dell alimentazione dell aria Precauzioni e Il tubo di alimentazione dell aria e il tubo di aspirazione dell aria devono essere avvolti con uno strato di isola mento termico per evitare perdite termiche e formazione di condensa Applicate innanzitutto Liquid Nail sulle tubature quindi collegate l isolamento termico con uno strato di pellicola d alluminio Utilizzate Liquid Nail per fissarlo Utilizzate infine nastro adesivo e pellicola d alluminio per sigillare attentamente i giunti altres possibile utilizzare altri materiali di isolamento di buona qualit e tubi di alimentazione dell aria e i tubi di uscita dell aria devono essere fissati agli assi prefabbricati del soffitto utilizzando dei sostegni in ferro giunti dei tubi devono essere sigillati con della colla per evitare perdite e Il design e l in
83. l filo di controllo tra il dispositivo di controllo a filo e l unit interna installato in modo superfi ciale utilizzate il tubo metallico n 1 e predisponete delle rientranze corrispondenti nella parete fate riferimento alla Figura 1 Se utilizzate l installazione a scomparsa potete utilizzate il tubo metallico n 1 fate riferimento alla Figura 2 4 A prescindere che si scelga l installazione superficiale o a scomparsa necessario eseguire 2 fori allo stesso livello la cui distanza dev essere la stessa distanza 60 mm dei fori di installazione nella piastra inferiore del dispositivo di controllo a filo Inserite quindi un tappo in legno in ciascun foro Fissate la piastra inferiore del dispositivo di controllo a filo alla parete utilizzando questi due fori Fissate il filo di controllo al pannello di controllo Infine installate il pannello del dispositivo di controllo a filo Attenzione Durante l installazione della piastra inferiore del dispositivo di controllo a filo prestate attenzione alla direzione della piastra inferiore Il lato della piastra con due scanalature deve essere posizionata in basso altrimenti non sar possibile installare correttamente il pannello del dispositivo di controllo a filo gt gt z e Coperchio del pannello elettrico N fo Schizzo cartografico per filo amp di controllo dell unit interna ee COANN SS NN Morsetto del filo Circuito incro
84. llo di tempo impostato 3 Premete nuovamente il tasto TIMER Il timer si attiva L unit inizia il conto alla rovescia Per annullare l impostazione del timer premete il tasto TIMER r e Per attivare il menu di impostazione SAVE premete contemporaneamente il tasto FAN ed il tasto W per 5 secondi quando l unit spenta Saranno visualizzati SAVE e COOL per la prima impostazione sar visualizzato il valore iniziale 26 Il limite minimo della temperatura viene visualizzato nell area della temperatura impostata e il valore della ssa temperatura lampeggia Per impostare il limite minimo rime della temperatura di raffreddamento premete il tasto A o il tasto Y Gamma d impostazione 16 30 ON OFF Premete il tasto ON OFF per confermare l impostazione Utilizzate il tasto A o il tasto W per impostare il limite di temperatura massimo il valore della temperatura lampegge r nella gamma della temperatura ambiente gamma OUT ENV gamma d impostazione 16 30 Premete il tasto ON OFF per confermare l impostazione Assicuratevi che il limite massi mo sia superiore al limite minimo della temperatura impostato in caso contrario il sistema considerer la temperatura pi elevata come limite massimo della temperatura e la tempe ratura pi bassa come limite minimo della temperatura Premete il tasto MODE per completare l impostazione SAVE per le modal
85. m the refrigerant pipe and the cables Use thermal insulation tape to wrap the pipes from the bottom of the outdoor unit until the upper end of the pipe where the pipe enters the wall When wrapping thermal insulation tape the later circle of tape must cover half of the front circle of tape Wrapped pipe must be fixed to wall using pipe clamps Caution After the pipes are wrapped by protective materials never bend the pipes to form very small angle and otherwise the pipes may be cracked or breaken Do not wrap the protective tape too tight and otherwise the efficiency of thermal insulation may be decreased Make sure that the drainage pipe is separate from the bundled pipes After the protective work is completed and the pipes are wrapped use seal material to seal the hole in the wall so as to prevent rain and wind from entering the room E 20 GREE_duct_eng_1022 indd 20 ae 08 10 27 ui 7 Le p a IT m Position and method of installing wire controller 1 One end of the control wire of the wire controller is connected with main board of electric box of indoor unit inside it should be tightened by wire clamp the other end should be connected with the wire controller Sketch map as shown in below The control wire be used for the indoor unit and wire controller which is the special control wire the length is 8 meters the material be adopted for the control wire should be metallic substance The wir
86. nit line connection GB X18JR GB X24JR Indoor unit i i POWER E 220 240V 50Hz Outdoor unit 220 240V 50Hz 1 Power cord 3G 2 5mm HO7RN F 2 Power cord 3G 1 0mm Hosw F main board GB X36JR Outdoor unit POWER 220 240V 50Hz main board GREE_duct_eng_1022 indd 23 main board Indoor unit main board E 23 3 Communication wire Type UL2835 twisted pair Size AWG24 220 240V 50Hz 1 Power cord 3G 6 0mm HO7RN F 2 Power cord 3G 1 0mm Hosw F 3 Communication wire Type UL2835 twisted pair Size AWG24 08 10 27 3 32 13 1 ii cous o 11 01 INSTRUCTIONS OF UNIT INSTALLATION Troubleshooting If your air conditioning unit suffers from abnormal operation or failure please first check the following points before repair Failure Possible Reasons The power supply is not connected Electrical leakage of air conditioning unit causes tripping of leakage switch The operating buttons are locked The control loop has failure The unit cannot be started Aw N There is obstacle in front of the condenser The unit operates The control loop is abnormal for a while and then Cooling operation is selected when the outdoor ambient stops temperature is above 43 C WN The air filter is dirty or blocked There is heat source or too many people inside the room The door or window is open There is obstacle
87. no interior tem de ser enrolada com material de isolamento t rmico e n o pode haver fendas entre a junta do tubo do refrigerante e a parede da unidade no interior Sem fendas Use fita adesiva para enrolar os tubos Use fita adesiva para atar o tubo do refrigerador aos cabos Para prevenir que a condensa o saia do tubo de drenagem separe o tubo de drenagem do tubo do refrigerador e os cabos Use fita de isolamento t rmico para enrolar os tubos a partir da parte inferior da unidade no exte rior at parte superior do tubo onde o tubo entra na parede Quando enrolar a fita de isolamento t rmico a ltima parte da fita tem de cobrir metade da segunda volta que a fita d ao rolo O tubo enrolado tem de ser fixado parede usando bra adeiras para tubos Aten o GREE duct por 1022 indd 20 de 08 10 27 ee Ap s ter enrolado os tubos com materiais protectores nunca dobre os tubos para formar ngulos muito pequenos caso contr rio pode rachar ou partir os tubos Nao aperte demasiado a fita adesiva caso contr rio a efici ncia do isolamento t rmico pode dimi nuir Certifique se de que o tubo de drenagem fica separado dos tubos atados Ap s ter terminado o trabalho de protecg o e os tubos estarem enrolados use material vedante para vedar o orificio na parede para impedir que a chuva e o vento entrem na sala P 20 TT p a 11 Im Posicao e m todo de instalacao do controlo do fio 1 Uma
88. non saranno memorizzati dopo una d caduta di corrente Premete il tasto ON OFF per memorizzare il valore im postato e chiudere l impostazione ON OFF e Quando l unit spenta premete contemporaneamen te il tasto FAN e il tasto SLEEP per attivare il menu di debug Sul display LCD sar visualizzato DEBUG In modalit debug premete il tasto MODE in modo da visualizzare 01 nell area della temperatura impostata alla sinistra di DEBUG Nell area OUT ENV alla de stra di DEBUG viene visualizzata l impostazione SLEEPI TIMER Premete il tasto A o il tasto W per selezionare una oi delle due impostazioni seguenti La temperatura ambiente misurata all entrata dell aria nell area OUT ENV viene visualizzato 01 La temperatura ambiente misurata nel dispositivo di controllo a filo nell area OUT ENV viene visualizzato 02 Il sensore di temperatura ambiente predefinito quello collocato nell entrata dell aria GREE_duct_ita_1022 indd 7 dp 08 10 27 3 33 37 FUNZIONAMENTO DEL DISPOSITIVO DI CONTROLLO A FILO Visualizzazione guasti e In caso di guasti nell unita ERROR lampeggia sul di splay del dispositivo di controllo a filo e viene visualiz zato il codice d errore corrispondente In caso di guasti multipli i codici d errore saranno visualizzati uno dopo l altro sul dispositivo d
89. o do ar e os tubos da entrada do ar t m de ser fixados nas placas pr fabricadas do tecto usando suportes de ferro As juntas dos tubos t m de ser vedadas com cola para evitar fugas e O design e instala o dos tubos do ar t m de estar em conformidade com o estado relevante dos crit rios de engenharia e A extremidade do tubo de entrada do ar tem de estar pelo menos 150 mm afastado da parede A entrada de ar tem de ser coberta com o filtro e Dever ter em conta o sil ncio e a absor o de choques no design e instala o dos tubos do ar Adicionalmen te a fonte de ru do pode ser colocada afastada do local onde as pessoas se encontram A entrada de ar n o se dever encontrar acima do local onde os utilizadores se encontram escrit rios e locais de descanso etc P 17 GREE duct por 1022 indd 17 dp 08 10 27 si v O A n Cc m 97 i cessa B Go SER INSTRU ES DE INSTALA O DA UNIDADE Instala o da tubagem de drenagem A tubagem de drenagem deve ser instalada com um ngulo de inclina o de 5 10 para facilitar a drenagem da condensa o As juntas da tubagem de drenagem t m de ser cobertas com mate riais de isolamento t rmico para evitar a gera o de condensa o no exterior Asa da de drenagem encontra se em ambos os lados direito e esquerdo da unidade interior Ap s seleccionar uma sa da de drenagem a outra sa da dever ser bloqueada com um tamp o
90. o temporizador encontra se entre as 0 5 e 24 horas 1 Prima o bot o TIMER temporizador para entrar no estado de defini o da temperatura A palavra TIMER come a a piscar no ecr 2 Prima o bot o A ou W para aumentar ou diminuir o tempo definido 3 Prima novamente o bot o TIMER O temporizador li gado A unidade come a a contar o tempo decorrido Para cancelar a configura o do temporizador prima o bot o TIMER Quando a unidade desligada prima o bot o FAN e o bot o W em simult neo durante 5 segundos para activar o menu de configura o SAVE guardar SAVE e COOL ser o apresentados para a primei ra configura o ser apresentado o valor inicial 26 O limite inferior da temperatura apresentado na rea da temperatura definida e o valor da temperatura co au mega a piscar Defina o limite inferior da temperatura Timer de arrefecimento e prima o bot o A ou o bot o W Raio da configura o 16 30 ON OFF Prima o bot o ON OFF para confirmar a configura o Use o bot o A ou o bot o W para definir o limite superior da temperatura e o valor da temperatura come a a piscar na area da temperatura ambiente rea OUT ENV Raio da configura o 16 30 Prima o bot o ON OFF para confirmar a configura o Certifique se de que a temperatura limite superior superior temperatura limite inferior caso
91. or 1 Insira um parafuso de expans o M10 no orifi cio Bata o prego de ferro no parafuso Con jo ee sulte o esbo o das dimens es do perfil da GA ee unidade do interior quanto a distancia entre A IZ orificios E gt Parafuso de mon Unidade de ar condicionado 2 Instale o gancho na unidade do interior tagem no tecto _ z 7 Fixador 3 Instale a unidade do interior no tecto Parafuso Z Z 7 Fixador 5 2 Yi ES DA PANS Porca i ENE F rl N J Entrada do ar N f Abastecimento i do ar Alargamento Precau es para uma instala o desfavor vel A prepara o de todos os tubos tubos de liga o e tubos de drenagem e cabos linhas de liga o do controlador do fio unidade no interior e unidade no exterior tem de estar pronta antes da instala o para se obter uma instala o sem percal os Fazer uma abertura no tecto Talvez seja necess rio suportar o tecto para assegurar a uniformi dade deste e para evitar a sua vibra o Consulte com o utilizador uma empresa de constru o para obter mais detalhes e No caso da for a do tecto n o ser suficiente use sec es de ferro em ngulo para criar um su porte em trave Coloque a unidade na trave e fixe a P 16 GREE duct por 1022 indd 16 dp 08 10 27 si Verifica o do n vel da unidade no interior Ap s ter instalado a unidade no interior certifique se de que verifica o nivel de toda a unidade A unidade tem de se
92. orretto del cavo pu provocare il surriscaldamento del cavo di alimentazione della spina e della presa elettrica con conseguente rischio di incendi 8 Se il cavo di alimentazione danneggiato deve essere sostituito dal produttore da un rivenditore autorizzato o da un tecnico qualificato in modo da evitare eventuali pericoli Sostituite il cavo di alimentazione solo con un cavo indi cato dal produttore PRECAUZIONI PER L USO 1 Aprite periodicamente una finestra o una porta per ventilare la stanza in particolare durante l utilizzo di apparecchi a gas Una ventilazione insufficiente potrebbe causare mancanza d ossigeno 2 Non toccate i tasti con le mani bagnate Ci potrebbe provocare scosse elettriche 3 Per garantire la sicurezza spegnete l interruttore disgiuntore quando non intendete usare l unit per un lungo pe riodo di tempo 4 Controllate la griglia di montaggio dell unit esterna periodicamente ed assicuratevi che sia fissata saldamente 5 Non collocate oggetti sull unit esterna e non salitevi sopra Ci potrebbe provocare la caduta di oggetti o persone con il conseguente rischio di lesioni 6 Questa unit stata progettata per l uso in zone residenziali Non usatela in altri luoghi quali canili o serre per l allevamento di animali o la coltivazione di piante 7 Non collocate contenitori d acqua sull unit Se l acqua penetra nell unit isolamento elettrico potrebbe subire dei danni con il conseguente
93. perature 3 e Under normal conditions the ENV and the room on E temperature are displayed Press the SLEEP button for 5 seconds The LCD will display OUT ENV The a outdoor temperature will show in the display for 10 seconds and then return to the room temperature NY OUTENV gt a FAN Ss E SLEEP TIMER ON OFF HSITSNA Memory function setting e When the unit is shut off press the MODE button for Es 10 seconds to switch set values so as to decide if the r unit operating status or shut off status is memorized after a power fail If the set temperature area displays 01 it means the unit operating status or shut off status shall be memorized after a power fail 02 means the operating status or shut off status will not be memorized Press the ON OFF button to store the set value and exit the setting A v TIMER ON OFF eo 6 I e When the unit is shut off press the FAN button and the SLEEP button simultaneously to activate the debug menu The LCD will display DEBUG Under the debug mode press the MODE button so as to display 01 on the set temperature area at the left of DEBUG The OUT ENV area at the right of a DEBUG displays setting status Press the A button or the W button to select from oi the following two settings The room temperature is measured at the ai
94. permitir um tratamento e reciclagem pr pria de acordo com a legisla o em vigor Por favor contacte as autoridades locais para mais detalhes nos esquemas de recolha e reciclagem P b Para a Suica As baterias usadas dever o ser devolvidas ao ponto de venda Para os outros pa ses fora da Uni o Europeia por favor contacte a sua autoridade local para o m todo correcto de disposic o das baterias usadas PT GREE_duct_cov_1022 indd 4 i 08 10 27 3 30 15 P INDICE Instrug es de funcionamento e Instru es importantes de seguranga P 2 e Opera o do controlador do fio cece eeeeeeeeeeeeees P 3 QN OFETIDSNdes o cella P 4 Controlo da ventoinha nenn P 4 Configura o da temperatura 1 1 gt P 4 Configura o da fun o de hibernar P 5 Configura o do modo de funcionamento P 5 Configura o do temporizador seen P 6 Configura o de guardar BORNERESBERENEEREPEREUEREDBERSUREETFEEERENEGEREREEE P 6 Apresenta o da temperatura no exterior P 7 Configura o da fun o de mem ria P 7 Configura o do sensor da temperatura da sala P 7 Apresenta o da falha cricca P 8 e Opera o do comando dist ncia
95. r colocada horizontalmente mas o tubo de condensag o devera ser instalado de modo obliquo de modo a facilitar a drenagem da condensa o Indicador de nivel P_ PAL SLA LT IIS Entrada do ar Abastecimento do ar Tubagem de la condensa o lt i Visualiza o ampliada Como o interior da unidade est no estado de press o negativa Tubagem de condensa o necess rio preparar uma curva em cotovelo para as guas paradas a Os requisitos sao A B2P 10 20 mm a P a press o absoluta dentro da unidade A unidade de press o Pa Instala o do tubo do ar rectangular Nome Fixador Tubo de entrada do ar Tubo do ar de lona Entrada do ar Filtro Tubo principal de abaste cimento do ar Montagem no tecto 7 Sa da de abastecimento do ar SS A Entrada do Se Abastecimento ZEAL ar NET do ar LA Cuidados e O tubo da alimenta o do ar e o tubo de entrada do ar t m de ser cobertos com uma camada de isolamento t rmico de modo a evitar fugas t rmicas e condensa o Primeiro aplique fixador l quido nos tubos e depois fixe o algod o de isolamento t rmico com uma camada de folha de alum nio Use a cobertura do fixador liqui do para fixar Finalmente use fita adesiva de alum nio para vedar cuidadosamente as juntas tamb m pode usar outros materiais de isolamento t rmico de qualidade e Os tubos de alimenta
96. r evitare che si formi della condensa nel tubo del fluido refrigerante e per evitare perdite il tubo del refrigerante deve essere avvolto con materiali di isolamento termico e con nastro adesivo e deve essere isolato dall aria 2 Il giunto di collegamento all unit interna deve essere avvolto in materiale di isolamento termico in modo che non vi siano spazi tra il giunto del tubo del fluido refrigerante e la parete dell unit inter na Nessuno spazio 3 Utilizzate nastro adesivo per avvolgere i tubi e Utilizzate nastro adesivo per avvolgere insieme il tubo del fluido refrigerante e i cavi Per evitare che la condensa trabocchi dal tubo di drenaggio separate il tubo di drenaggio dal tubo del fluido refrigerante e dai cavi e Utilizzate nastro di isolamento termico per avvolgere i tubi dalla parte inferiore dell unit esterna fino all estremit superiore del tubo nel punto in cui il tubo entra nel muro Quando avvolgete i tubi con nastro di isolamento termico un giro di nastro deve coprire la met anteriore del giro di nastro precedente e tubi avvolti devono essere fissati al muro utilizzando morsetti per tubi Attenzione Dopo aver avvolto i tubi con materiali protettivi non piegate i tubi fino a formare un angolo molto ridotto altrimenti i tubi potrebbero incrinarsi o rompersi e Non avvolgete troppo stretto il materiale protettivo altrimenti l efficacia dell isolamento termico po trebbe risultare ridotta A
97. r intake The OUT ENV area displays 01 The room temperature is measured at the wire controller The OUT ENV area displays 02 The default room temperature sensor is set at the air intake TIMER GREE_duct_eng_1022 indd 7 T 08 10 27 3 32 06 IA 7 p a IT m WIRE CONTROLLER OPERATION Failure Display E o ERROR e When there is failure in the unit operation the ERROR will flash on the display of the wire controller and the error code will also be displayed When there are multiple failures the error codes will be displayed one after one on the wire controller The two digits indicate the detailed the error code The Error Codes Definitions are as Follows Error code Fault EO Pump Failure E1 Compressor High Pressure Protection E2 Indoor Frost Proof Protection E3 Compressor Low Pressure Protection E4 Compressor Exhaust High Temperature Protection E5 Compressor Overheat And Inverter Driving Protection E6 Communications Failure E8 Indoor Fan Protection E9 Full Water Protection Connected control communications Failure Failure of Indoor Room Sensor at Air Intake Failure of Evaporator Temp Sensor Failure of Condenser Temp Sensor Failure of Outdoor Ambient Sensor Failure of Exhaust Temp Sensor Failure of Indoor Room Sensor at Wire Controller
98. r o tecto Instala o do tubo do refrigerante Selec o do tubo do refrigerante Tamanho do tubo de liga o do tubo de Tamanho do tubo de liga o Altura m xima Quantidade de refrigerante Tamanho m ximo Diferen a entre a unidade adicional a ser inserida Modelo Tubo do g s Tubo do l quido do tubo m eu e a unidade exte ues tamanho extra do Nota e O comprimento padr o do tubo de 5 m Se o comprimento do tubo exceder os 5 m adicione l quido refrigerante Conforme apresentado na tabela em cima e Use tubos com uma grossura de 0 8 mm 1 0 mm 1 2 mm O tubo dever conseguir aguentar a press o de 6 0 MPa e Quanto mais comprido for o tubo do refrigerante menor ser o efeito de arrefecimento e de aque cimento P 18 GREE duct por 1022 indd 18 dp 08 10 27 sani nee o o TOO Liga o do tubo 1 Alinhe a extremidade alargada do tubo de cobre com o centro da junta roscada Aperte manual mente a porca da extremidade alargada 2 Use a chave dinamom trica para apertar a porca de alargamento at que a chave fa a um ru do Di metro do tubo Grossura do tubo Bin rio de aperto 1642 N m Ef alargamento Tubo 3824 Nm Tubo para unidade ida my AO CE 9 fo Chave L ai Chave dinamom trica 3 O ngulo de dobragem do tubo n o pode ser muito largo caso contr rio o tubo pode partir se Use uma ferramenta adequada para dobrar o tubo 4 Enrole o tubo
99. r supervisionadas para se assegurar de que estas n o brincam com o aparelho 12 Quando ligado o ar condicionado n o dever ser desligado pelo menos durante 5 minutos ou mais caso contr rio o retorno do leo para o compressor pode ser afectado AVISOS QUANTO INSTALA O REMO O REPARA O N o tente instalar remover reparar a unidade sozinho O funcionamento incorrecto pode causar choques el ctricos fugas de gua fogo etc Consulte o seu revendedor ou outro pessoal qualificado para a instala o remo o repa ra o da unidade Esta unidade dever ser usada em escrit rios restaurantes resid ncias ou lugares semelhantes Por favor instale a unidade num local suficientemente forte para suportar o peso de um ar condicionado Caso contr rio o ar condicionado pode cair e dar origem a les es ou morte O aparelho n o dever ser instalado na lavandaria CUIDADOS QUANTO LOCALIZA O INSTALA O Certifique se que liga o ar condicionado alimenta o com a voltagem nominal e frequ ncia correctas A utiliza o de uma alimenta o com uma frequ ncia e voltagem inadequadas pode dar origem a danos no equi pamento e poss vel fogo N o instale a unidade num local onde possa haver fugas de g s inflam vel Isso pode dar origem a fogo Instale a unidade num local com pouco p fumos e humidade no ar Coloque a mangueira de drenagem para assegurar uma drenagem sem percal os Uma drenagem insufic
100. rc may arise All line connections must conform to the schematic diagram of lines Wrong connection may cause abnormal operation or damage of the air conditioning unit Do not let any cable contact the refrigerant pipe the compressor and moving parts such as fan Do not change the internal line connections inside the air conditioning unit The manufacturer shall not be liable for any loss or abnormal operation arising from wrong line connections Power cable connection 1 Remove the front side panel of the outdoor unit 2 Pass the cable through rubber ring 3 Connect the power supply cable to the L N terminals and the grounding screw on the metal electric box 4 Fix the cable with cable fastener Recommend circuit breaker and power cable Model Power supply Circuit breaker Min cross sectional area of power cable GB X18JR 220 240V 50Hz 6A GU X18JR 220 240V 50Hz aan l 220 240V 50Hz 6A e If the power cable is longer than 15 meters please enlarge the cross section of power cable adequately in order to avoid the accident due to overload E 22 i nua p Bo el Caution Take great care when carrying out the following connections so as to avoid malfunction of the air conditioning unit because of electro magnetic interference The signal line of the wire controller must be separated from the power line and the connecting line between the indoor unit and the outdoor unit In case the
101. re a 43 C 1 Il filtro dell aria sporco o bloccato 2 E presente una fonte di calore o ci sono troppe persone all interno della stanza ni 3 La porta o la finestra sono aperte o 4 E presente un ostacolo davanti all entrata o all uscita dell aria dotta 5 La temperatura impostata troppo alta e ci ostacola il raffreddamento 6 Vi sono perdite di fluido refrigerante 7 Le prestazioni del sensore della temperatura ambiente si ridu cono 1 Il filtro dell aria sporco o bloccato 2 La porta o la finestra non sono completamente chiuse Efficienza del 3 La temperatura ambiente impostata troppo bassa e ci riscaldamento ostacola il raffreddamento ridotta 4 Vi sono perdite di fluido refrigerante 5 La temperatura ambiente esterna inferiore a 5 C 6 Il funzionamento della linea di controllo presenta delle anomalie Nota Se avete controllato i punti di cui sopra e avete preso i provvedimenti necessari per risolvere i pro blemi rilevati ma il condizionatore d aria non funziona ancora correttamente arrestatelo immedia tamente e contattate il rivenditore autorizzato SHARP di zona Lunita dev essere riparata solo da personale qualificato l 24 GREE_duct_ita_1022 indd 24 ae 08 10 27 3 33 43 i Ue p So IT m Manutenzione Manutenzione di routine Pulizia del filtro del aria deve essere eseguita da personale qualificato Non smontate il filtro dell aria
102. ress A or W button to increase or decrease the set time 3 Press the TIMER button again The timer will go into effect The unit will start to count the time passed To cancel timer setting press the TIMER button SAVE setting e When the unit is shut off press the FAN button and the W button simultaneously for 5 seconds to activate the SAVE setting menu The SAVE and COOL will be displayed For the first setting the initial value will be displayed 26 The lower limit of temperature will be displayed on the set temperature area and the temperature value will SER be flashed Set the lower limit of cooling temperature TIMER to press the A button or the W button rang of setting 16 30 ON OFF Press the ON OFF button to confirm the setting Use the A button or the W button to set the upper limit of temperature and the temperature value will fiash on the ambient temperature area OUT ENV area rang of setting 16 30 Press the ON OFF button to confirm the setting Take care that the upper limit temperature must be higher than the set lower limit temperature Otherwise the system will regard the higher temperature as the upper limit temperature and the lower one as the lower limit temperature Press the MODE button to complete the SAVE setting for the modes of cooling and dehumidifying and turn to the SAVE setting for the heating mode The SAVE and
103. s a uma dist ncia de at 8 metros Nunca deixe cair nem atire o comando dist ncia Nunca deixe entrar qualquer l quido no comando dist ncia Evite a exposi o do comando dist ncia luz directa do sol N o coloque o comando dist ncia num local extremamente quente e O bot o SWING n o funciona com esta unidade Bot o FAN Prima para definir a ve locidade da ventoinha SWING FAN Pe AUTOFAN adl crer AUTO ul dk ed Janela do receptor Bot o TEMP Prima para definir a tem peratura adequada SINONLYOd Bot o MODE Prima para definir o mm MODE ON OFF modo de funcionamento Bot o ON OFF Prima para iniciar ou terminar a opera o Colocar as pilhas Ap s ter colocado as pilhas o ecr apresenta os cones e c digos de le tras de todas as fun es e A dura o de vida das pilhas cerca de 1 ano e N o misture pilhas novas com pilhas usadas nem diferentes tipos de pilhas e Se o comando dist ncia n o for usa do durante um longo per odo de tempo retire as pilhas para evitar derrames e a consequente falha do aparelho e Coloque duas pilhas R03 AAA Acess rios GREE duct por 1022 indd 9 dp 08 10 27 ui OPERA O DO COMANDO A DIST NCIA Funcionamento do modo frio COOL 1 Prima o bot o ON OFF Q 2 2 Prima o bot o MODE para
104. se contact your local authority for further details If your used electrical or electronic equipment has batteries or accumulators please dispose of these separately beforehand according to local requirements By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling 2 In other Countries outside the EU If you wish to discard this product please contact your local authorities and ask for the correct method of disposal For Switzerland Used electrical or electronic equipment can be returned free of charge to the dealer even if you don t purchase a new product Further collection facilities are listed on the homepage of www swico ch or www sens ch B Information on Disposal for Business Users 1 In the European Union If the product is used for business purposes and you want to discard it Please contact your SHARP dealer who will inform you about the take back of the product You might be charged for the costs arising from take back and recycling Small products and small amounts might be taken back by your local collection facilities For Spain Please contact the established collection system or your local authority for take back of your used products 2 In other Countries outside the EU If you wish to discard o
105. senta o do temporizador TIMER Apresenta o da velocidade da ventoinha Auto Alta M dia Baixa Apresenta o de descongelar DEFROST Apresenta o de guardar SAVE Apresenta o da temperatura definida Apresenta o da temperatura ambiente Apresenta o do modo fresco seco ventoinha calor auto Apresenta o da falha Apresenta o de adormecer SLEEP Bot o MODE Bot o de configura o da temperatura para subir a temperatura Bot o de configura o da temperatura para descer a temperatura Bot o FAN Bot o SLEEP verifica o da temperatura no exterior Bot o TIMER Bot o ON OFF Janela do receptor 1 2 3 4 5 6 7 8 9 oO GREE_duct_por_1022 indd 3 de 08 10 27 3 35 07 ON OFF ligar desligar r AUTO i FAN W SPEED iy SET ENV a T cc E 5 E 9 SLEEP COOL TIMER ON OFF e Prima o bot o ON OFF para ligar a unidade Prima o bot o ON OFF novamente para desligar a uni dade Controlo da ventoinha as imagens apresentam as reas de apresenta o relevantes r FAN i SPEED MW FAN SLEEP TIMER ON OFF e os o bot o FAN para mudar a velocidade da ventoi m Baixa M dia Alta gt Auto I No modo DRY a velocidade da ventoinha amp definida automaticamente para baixa Configurag o da temperatura
106. spensione al soffitto Vite Sospensione lt 48mm _ Dado Wa Alimentazione i dell aria I Ampliamento to e tubi di drenaggio e cavi linee di collegamen e unit esterna deve essere eseguita prima dell installazione in modo che questa non venga interrotta che questo sia uniforme e per evitare vibrazioni societ edilizia Trapanare un apertura sul soffitto Potrebbe essere necessario sostenere il soffitto per garantire Per ulteriori dettagli rivolgetevi all utente o alla Nel caso in cui la forza del soffitto non sia sufficiente utilizzate sezioni di ferro angolare per in stallare dei sostegni per le travi Collocate l unit sulla trave e fissatela I 16 lt GREE_duct_ita_1022 indd 16 08 10 27 3 33 40 Controllo del livello dell unita interna Dopo aver installato l unit interna assicuratevi di controllare il livello dell intera unit Lunita dev essere installata in posizione orizzontale ma il tubo di drenaggio della condensa deve essere installato in posizione obliqua in modo da facilitare il drenaggio della condensa Indicatore di livello P_ PALA LA f IL Tubo di i 4 Sn m i Es Entrata dell aria b Alimentazione dell aria condensa l Y x 1 lt i o co Pa Se Immagine ingrandita Es Poich l interno dell unit in uno stato di pressione negat
107. ssicuratevi che il tubo di drenaggio sia separato dai tubi avvolti insieme e Dopo aver completato il lavoro protettivo e dopo aver avvolto i tubi utilizzate del materiale sigillan te per sigillare il foro nella parete per evitare che pioggia e vento entrino nella stanza I 20 GREE_duct_ita_1022 indd 20 de 08 10 27 3 33 42 1 lion p Bo 11 Im Posizione e metodo di installazione del dispositivo di controllo a filo 1 Un estremita del filo di controllo del dispositivo di controllo a filo collegata con la scheda madre del pannello elettrico dell unit interna essa deve essere serrata con un morsetto per filo mentre l altra estremit deve essere collegata al dispositivo di controllo a filo secondo lo schizzo carto grafico illustrato di seguito Il filo di controllo utilizzato per l unit interna e per il dispositivo di controllo a filo si tratta di uno speciale filo di controllo lungo 8 metri il materiale del suddetto filo dovrebbe essere un materiale metallico Il dispositivo di controllo a filo non pu essere smontato e il filo di controllo utilizzato per il dispositivo di controllo a filo non deve essere sostituito dall utente installazione e manutenzione devono essere eseguite da personale qualificato 2 Selezionate una posizione di installazione In base alle dimensioni del filo di controllo del dispositi vo di controllo a filo lasciate una rientranza o un foro in modo da interrare il filo 3 Se i
108. stallazione dei tubi dell aria devono essere conformi ai relativi criteri nazionali di progettazione Il bordo del tubo di entrata dell aria deve essere ad almeno 150 mm di distanza dal muro L entrata dell aria deve essere coperta da un filtro e Prendete in considerazione provvedimenti ammortizzanti e di silenziamento nel design e installazione dei tubi dell aria Inoltre la fonte di rumore deve essere lontana da luoghi frequentati da persone L entrata dell aria non deve essere collocata sopra luoghi frequentati da persone uffici luoghi di riposo ecc l 17 GREE_duct_ita_1022 indd 17 de 08 10 27 3 33 41 gt gt z fe ISTRUZIONI PER L INSTALLAZIONE DELL UNITA Installazione delle tubature di scarico Le tubature di drenaggio devono essere installate con un angolo di inclinazione compreso tra 5 e 10 in modo da facilitare il drenaggio della condensa giunti delle tubature di drenaggio devono essere ri coperti con materiali di isolamento termico in modo da evitare che si formi della condensa all esterno e Vi sono uscite di drenaggio sia sul lato destro che sul lato sinistro dell unit interna Dopo aver scelto un uscita di drenaggio bloccate l altra uscita utilizzando un tappo in gomma Avvolgete l uscita bloccata con del cordoncino per evitare perdite e utilizzate i materiali di isolamento termico per avvolgere l uscita bloccata Quando l unit viene spedita
109. sti premete nuova mente i due tasti contemporaneamente per 5 secondi Gamma di impostazioni della temperatura e Riscaldamento 16 C 30 C e Raffreddamento 16 C 30 C e Deumidificazione 16 C 30 C e Ventola Nessuna funzione di impostazione della tem peratura qe 08 10 27 3 33 35 Impostazione della funzione di attesa e Modalit RAFFREDDAMENTO o DEUMIDIFICAZIONE Un ora dopo aver premuto il tasto SLEEP la tempera tura impostata aumenta di 1 C e dopo 2 ore aumenta ancora di 1 C e Modalit RISCALDAMENTO Un ora dopo aver premuto il tasto SLEEP la tempera tura impostata diminuisce di 1 C e dopo 2 ore diminui sce ancora di 1 C SLEEP TIMER onorr e Non possibile impostare la funzione di attesa in mo dalit Ventole ONVITVLI Impostazione della modalita di funzionamento e Premete il tasto MODE per selezionare la modalit di funzionamento Bi DRY gt FAN ee v E se Modalit RAFFREDDAMENTO COOL E E La temperatura impostata deve essere inferiore alla temperatura ambiente Se la temperatura impostata superiore alla temperatura ambiente l unit non sar in grado di raffreddare l ambiente e funzioner semplice mente in modalit Ventola Modalit DEUMIDIFICAZIONE DRY Il motore delle ventole si attiva a bassa velocit nella gamma di temperature impostata L effetto di deumidi ficazione di questa
110. to Diametro esterno x Modello Tubo del fluido Tubo del ei spessore delle pareti ica p a OO ISTRUZIONI PER L INSTALLAZIONE DELL UNIT GB X18JR Ur fof fg yy PREGA ASP DS Dado con rondella Ps 7 IE SSD Rondella spaccata MIN 250 GB X24JR GB X36JR G AE s AR da n i 7 rondella Rondella spaccata Z Y ip 77 lt MIN 250 PP ikl RE 220 44 DL LD SI 4 4 4 4 N x NN IH EEE GEN A MIN 2 500 MIN 250 Avvertenza AN Pg MIN 250 Unita di misura della lunghezza mm L altezza di installazione per l unit interna deve essere di 2 5 m o superiore GREE_duct_ita_1022 indd 14 I 14 08 10 27 3 33 39 Li liu p Bo 11 Im Unita esterna Modello Coogl Cc E 9 Unit di misura della lunghezza mm Articolo A B We D JE gt Modello gt GU X18JR 848 320 540 548 286 GU X24JR 913 378 680 548 340 GU X36JR 1032 412 1250 572 378 a TED ESE EEE MIN 1 000 v MIN 500 MIN 500 MIN 500 MIN 2 000 4 MiNi S00 i MIN 2 000 L ESTEET E e Fui Precauzioni per l installazione dell unit esterna Per garantire il corretto funzionamento dell unit scegliete il luogo di installazione secondo quanto segue e L unit esterna deve essere installata in modo che l aria scari
111. tripper to strip the insulation layer 25mm long from the end of the single wire 2 Remove the screw from the terminal board of the air conditioning unit 3 Use pliers to bend the end of the single wire so that a loop matching the screw size is formed 4 Put the screw through the loop of the single wire and fix the loop at the terminal board Connection of multiple twisted wires 1 Use wire stripper to strip the insulation layer 10mm long from the end of the multiple twisted wires 2 Remove the screw from the terminal board of the air conditioning unit 3 Use crimping pliers to connect a terminal matching the size of the screw at the end of the multiple twisted wires 4 Put the screw through the terminal of the multiple twisted wires and fix the terminal at the terminal board Warning If the power supply flexible line or the signal line of the equipment is damaged only use special flexible line to replace it Before connecting lines read the voltages of the relevant parts on the nameplate Then carry out line connection according to the schematic diagram The air conditioning unit shall have special power supply line which shall be equipped with electricity leakage switch and air switch so as to deal with overload conditions The air conditioning unit must have grounding to avoid hazard owing to insulation failure All fitting lines must use crimp terminals or single wire If multiple twisted wires are connected to terminal board a
112. ts Do not place a vessel with water on the unit If water penetrates into the unit electrical insulations may deteriorate and cause electric shock Do not block the air inlets nor outlets of the unit It may cause insufficient performance or troubles Be sure to stop the operation and turn the circuit breaker off before performing any maintenance or cleaning A fan is rotating inside the unit and you may get injured 10 Do not splash or pour water directly on the unit Water can cause electrical shock or equipment damage 11 This appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance 12 Once started the air conditioner shall not be stopped at least after 5 minutes or longer otherwise the oil return to compressor may be affected WARNINGS FOR INSTALLATION REMOVAL REPAIR e Do not attempt to install remove repair the unit by yourself Incorrect work will cause electric shock water leak fire etc Consult your dealer or other qualified service personnel for the installation removal repair of the unit This unit shall be used in offices restaurants residences or similar places Please install at a place strong enough to support the weight of air conditioner unit If not the air conditioner unit might fall down and cause human injury or death e The appliance shall not be installed in the laundry a A D DAWN SQ co 0
113. tura Tasto TIMER Tasto ON OFF Finestra del ricevitore GREE_duct_ita_1022 indd 3 de 08 10 27 3 33 34 4 FUNZIONAMENTO DEL DISPOSITIVO DI CONTROLLO A FILO ON OFF pas AUTO EN AN W SPEED Bee Gage COOL SLEEP TIMER ON OFF e Premendo il tasto ON OFF l unit si accende e Premendo nuovamente il tasto ON OFF l unit di spe gne Controllo ventola dati visualizzati nelle relative aree del display r FAN i SPEED MW FAN SLEEP TIMER ON OFF e Premete il tasto FAN per modificare la velocit ventole e Alta gt Auto 1 Nella modalita DEUMIDIFICAZIONE la velocita vento le impostata automaticamente su Bassa Impostazione della temperatura r o SLEEP TIMER ONIOFF GREE_duct_ita_1022 indd 4 Premete il tasto di impostazione della temperatura A per aumentare la temperatura impostata Premete il tasto di impostazione della temperatura W per ridurre la temperatura impostata Premendo i tasti una sola volta l impostazione della temperatura varia di 1 C NOTA Funzione di blocco tasti Premendo contemporaneamente i tasti A e W per 5 secondi nell area della temperatura impostata visua lizzato EE e tutti i tasti vengono disattivati Per annullare la funzione di blocco ta
114. und gauge Hexagon socket screw key Fully open gt B open H Fully open gt 3 Connect Close Cap gt Q 9 Disconnect Remove Remove gt Cap N Replace Replace NQ a Vacuum pump adapter D Service port cap Remove CD Vacuum pump Replace cP Operate Tum off GREE duct eng 1022 indd 19 de 08 10 27 ui nee o 11 01 UNIT INSTALLATION INSTRUCTIONS Caution When connecting the indoor unit with the refrigerant pipe do not pull the big and small joints of the indoor unit forcefully so as to prevent the capillary of the indoor unit and other pipes from breaking and leaking e The refrigerant pipe shall be supported by proper bracket The weight of the pipe shall not be withstand by the unit Installation of protective layer of refrigerant pipe 1 To avoid generation of condensate on the refrigerant pipe and avoid leakage the refrigerant pipe must be covered by thermal insulation materials be bundled by adhesive tape and be isolated from air 2 The joint connecting to the indoor unit must be wrapped by thermal insulation material to be no gap between the refrigerant pipe joint and the wall of the indoor unit 3 Use adhesive tape to wrap the pipes Use adhesive tape to bundle the refrigerant pipe and the cables together To prevent condensate from overflowing out from the drainage pipe separate the drainage pipe fro
115. unidade do interior devera ser acima de 2 5 m P 14 GREE_duct_por_1022 indd 14 de 08 10 27 sai Unidade no exterior Modelo Coogl Cc E 9 Unidade de medi o mm Item A B C D E Modelo GU X18JR 848 320 540 548 286 GU X24JR 913 378 680 548 340 GU X36JR 1032 412 1250 572 378 Pu TETI MIN 1 000 v MIN 500 MIN 500 MIN MIN 2000 MIN 500 MIN 2000 Bel pza BE Precau es de instala o da unidade do exterior Para assegurar que a unidade funciona correctamente a escolha do local de instala o dever es tar em conformidade com os seguintes princ pios A unidade do exterior dever ser instalada de modo que o ar descarregado pela unidade do ex terior n o volte para dentro e que haja espa o suficiente em redor da m quina para a reparar O local de instala o tem de ter boa ventila o de modo que a unidade do exterior possa fazer entrar e sair ar suficiente Certifique se que n o existem obst culos na entrada e sa da de ar da unidade do exterior Se houver algum obst culo a bloquear a entrada e sa da do ar retire o e O local da instala o dever ser suficientemente forte para suportar o peso da unidade do ex terior e dever ser capaz de isolar o ru do e impedir a vibra o Certifique se de que o vento e o ru do da unidade n o afectam os seus vizinhos Evite a exposi o da unidade luz direct
116. unit is installed in a place vulnerable by electro magnetic interference it is better to use shielded cable or double twisted cable as the signal line of the wire controller Connection of signal line of wire controller 1 Open the the electric box cover of the indoor unit 2 Pull the signal cable of the wire controller through the rubber ring 3 Plug the signal line of the wire controller onto the 4 bit pin socket at the circuit board of the indoor unit CN10 of the wire controller connect with CN3 of the indoor unit 4 Fix the signal cable of the wire controller with cable fastener HSITONA Earth leakage breaker Provide an earth leakage breaker in order to protect against electric shock in case of leak e Use the current activated high sensitivity high speed type breaker with a rated sensitivity current of below 30mA and an operating time of below 0 1 second Requirement for ground e Ground the air conditioner without fail Do not connect the grounding wire to gas pipe water pipe lightning rod or telephone grounding wire Incomplete grounding may cause electric shock e The yellow green two color wiring of air conditioner is grounding wire and can not be used for ot purposes It cannot be cut off and be fixed by screw otherwise it would cause electric shock Cable connecting diagram of unit The section area of cables selected by users must not be smaller than the specifications shown diagram Schematic diagram of u
117. ure elettriche o elettroniche usate hanno batterie o accumulatori l utente dovr smaltirli a parte preventivamente in conformit alle disposizioni locali Lo smaltimento corretto del presente prodotto contribuir a garantire che i rifiuti siano sottoposti al trattamento al recupero e al riciclaggio necessari prevenendone il potenziale impatto negativo sull ambiente e sulla salute umana che potrebbe derivare da un inadeguata gestione dei rifiuti 2 In paesi che non fanno parte dell UE Se si desidera eliminare il presente prodotto contattare le autorit locali e informarsi sul metodo di smaltimento corretto Per la Svizzera Le apparecchiature elettriche o elettroniche usate possono essere restituite gratuitamente al rivenditore anche se non si acquista un prodotto nuovo Altri centri di raccolta sono elencati sulle homepage di www swico ch o di www sens ch B Informazioni sullo smaltimento per gli utenti commerciali 1 Nell Unione europea Se il prodotto impiegato a scopi commerciali procedere come segue per eliminarlo Contattare il proprio rivenditore SHARP che fornir informazioni circa il ritiro del prodotto Potrebbero essere addebitate le spese di ritiro e riciclaggio Prodotti piccoli e quantitativi ridotti potranno essere ritirati anche dai centri di raccolta locali Per la Spagna Contattare il sistema di raccolta ufficiale o l ente locale preposto al ritiro dei prodotti usati 2 In paesi che non fanno parte dell
118. v rios fios enrolados e fixe o terminal no quadro do terminal Aviso Se a linha flex vel da alimenta o ou a linha do sinal do equipamento ficar danificada use apenas uma linha flex vel especial para a substituir e Antes de ligar as linhas leia as voltagens das pe as relevantes na placa das especifica es A seguir efectue a liga o da linha de acordo com o diagrama esquem tico e Aunidade de ar condicionado dever ter uma linha especial de alimenta o que dever estar equipada com um interruptor de fugas de electricidade e interruptor do ar para lidar com situa es de sobrecarga e A unidade de ar condicionado tem de ter liga o terra de modo a evitar perigos devido a falhas no isolamento e Todas as linhas de liga o t m de usar terminais dobrados ou de fio nico Se ligar v rios fios enrolados ao quadro do terminal poder ocorrer uma descarga el ctrica e Todas as liga es de linha t m de estar em conformidade com o diagrama esquem tico das linhas Uma liga o errada pode dar origem a um funcionamento anormal ou danos na unidade de ar condicionado e N o deixe nenhum cabo entrar em contacto com o tubo do refrigerante compressor e pe as em movimento como a ventoinha e N o altere as liga es da linha interna dentro da unidade de ar condicionado O fabricante n o se responsabiliza por perdas ou funcionamento anormal devido a liga es erradas da linha Liga o do cabo da alimenta o 1 Ret

Download Pdf Manuals

image

Related Search

Related Contents

lisyme 40 - West Penetone Canada  Accessories Accessorios Accessories  取扱説明書  Wharfedale SI Series User's Manual  Philips Pure Essentials Collection Food processor tool holder HR3920  Speco Technologies SP30PT User's Manual  ACTi D22V surveillance camera  Kamai - User`s Guide v1.0 NTSC (URC)  Digitale baby weegschaal • Pèse-bébé numérique Digital baby  Samsung MR16 GU5.3 3000K 12V 5.8W  

Copyright © All rights reserved.