1. ati Capsula richiedere una riparazione del guasto mare la capsula Se l errore persiste sostituire la capsula Risistemare la capsula e L elemento CO troppo caldo Se l errore persiste sostituire la capsula i danneggi non Spegnerlo lasciarlo raffreddare per 5 minu La capsula eee ores Lo posizionata correttamente Riaccendere l unit e ripetere lo stesso test sie Troppo Caldo uu Errore di lettura Risistemare la capsula Se viene visualizzato lo stesso messaggio Capsula i Se l errore persiste sostituire la capsula rivolgersi al centro di assistenza di zona e P i P riparare il guasto Risistemare la capsula Se l errore persiste sostituire la capsula www testifire com 24 7 Assistenza 7 1 Assistenza tecnica Per assistenza e ulteriori informazioni rivolgersi a No Climb Products Ltd Edison House 163 Dixons Hill Road Welham Green Herts AL9 7JE United Kingdom Tel 44 0 1707 282760 Fax 44 0 1707 282777 Email support testifire com Disponibilita di una guida on line su www testifire com 7 2 Aggiornamenti del firmware Tutte le unita di teste Testifire sono dotate di una porta Mini B USB integrata a lato del corpo Fig 54 A Utilizzando il cavo piatto USB da A Standard a B Mini a 5 pin B possibile collegare Testifire a un computer per consentire il caricamento degli aggiornamenti software C T
2. Conservazione del manuale Conservare tutte le istruzioni operative e di sicurezza per future consultazioni Annotazione degli avvertimenti Leggere attentamente e attenersi a tutte le etichette di avvertimento presenti sul prodotto e a quelle descritte nel presente manuale Acqua e umidita Questo prodotto stato concepito per il solo uso indoor e non deve essere esposto n utilizzato in ambienti umidi Manutenzione Affinch il proprio prodotto Testifire funzioni come previsto necessario sottoporlo a regolari interventi di manutenzione Un periodo standard di manutenzione ogni 12 mesi In condizioni di utilizzo estreme potrebbero essere necessari interventi di manutenzione anticipati dispositivi Testifire dispongono di un timer incorporato che avvisa l utente quando necessario un intervento di manutenzione o quando l intervallo di manutenzione stato superato Per maggiori informazioni ved sezione 7 5 prodotti Testifire sono strumenti elettronici di precisione e pertanto necessario prestare la massima attenzione quando li si maneggia e conserva Facendo cadere un dispositivo su una superficie vi il rischio di danneggiarlo Si raccomanda di maneggiare questi prodotti con la massima cura e attenzione In questo modo funzioneranno per molti anni AI fine di proteggere i componenti tecnologici ad alta precisione contenuti nei dispositivi Testifire si raccomanda di non lasciare mai i dispositivi Testifire a pr
3. La porta USB del computer potrebbe non essere funzionante Pi di un Testifire collegato al computer allo stesso tempo amp testifire Testifire Flash Loader Yersion 1 00 Testifire Firmware Upgrade Utility 2008 No Climb Products Ltd All rights reserved http ann testifire com To continue click Next www testifire com 32 Passo 5 La fase seguente quella del caricamento del file del firmware di Testifire nell applicazione Premere il pulsante Open per selezionare il file dall hard disk del computer oppure il comando Download per scaricare automaticamente l ultima versione del firmware dal sito di Testifire Testifire Flash Loader Download the lastest file from the Internet Recommended a Open file from disk Advanced Selection Una volta selezionato il file viene evidenziato e il numero della versione visualizzato Testifire Flash Loader Download the lastest file from the Internet Recommended Download 100 Download complete Open file from disk Advanced 7 Selection Vv Testifire Firmware Version V5 2 To continue click Next Ks a Passo 6 Lanciare il processo di programmazione selezionando il pulsante Program Testifire viene portato in Boot Loader Mode automaticamente e il nuovo firmware viene scaricato Testifire Flash Loader Click Program to start t
4. AR 6001 x 2 Solo 100 x 1 g testifire As x 2 Solo 100 x 1 e gt A 9001 x 2 Solo 100 ta gt Solo 101 x 3 gt testifire 1 ie e o o o x 2 Solo 100 7 Solo 101 x 3 Accessori Infrared Carica Attrezzo Valigettadi Altezza Altezza Remote Batteria batterie universale per transporto accesso di accesso Control a bastone rapido larimozione protettiva fino a 6m fino a 9m T Testifire 25 Solo 200 ae Solo 760 Solo 725 Altezza di accesso dei pali Solo Pg Solo Altezza di accesso N modello circa max f too mem 6m 20ft e d olo 100 Solo 100 x 1 100 101 1 Solo 100 Solo 101 x 3 Solo 610 fo 4 gt testitire www testifire com 36 10 Accordo di licenza con l utente finale IMPORTANT NOTICE PLEASE READ CAREFULLY BEFORE EITHER A DOWNLOADING ANY SOFTWARE FROM THIS WEBSITE OR BJOPENING THE PACKAGING OR C INSTALLING THE SOFTWARE This Agreement for Supply of Products and Software Agreement is a legal agreement between you Licensee or you and No Climb Products Limited Licensor or we for i the Licensor s Product and ii all related software and all future upgrades thereto Software This Agreement also applies to any data supplied with the Software associated media print
5. an lt gt testifire TESTER PERRIVELATORE MULTISTIMOLO Manuale dell utente Q testers www testifire com testifire TESTER PERRIVELATORE MULTISTIMOLO Manuale dell utente Il presente manuale fornisce informazioni sul corretto utilizzo dei tester per rivelatori testifire serie 1000 e 2000 tra cui Testa Testifire 1000 Kit di controllo Testifire 1001 Kit di controllo Testifire 6001 Kit di controllo Testifire 9001 Testa Testifire 2000 Kit di controllo Testifire 2001 Kit di controllo Testifire 6201 Kit di controllo Testifire 9201 Capsule sostitutive Capsula TS3 fumo Capsula TC3 CO Articoli supplementari Solo 760 Battery Baton Caricabatterie Solo 725 rapido universale Attrezzo universale per la rimozione del rivelatore Solo 200 Custodia Valigetta di trasporto protettiva per Solo 610 Telecomando a infrarossi Testifire 25 Modulo RFID Bluetooth Testifire 100 A pagina 28 del presente manuale dell utente riportato un sistema di selezione completo di componenti e kit Testifire Per ulteriori informazioni o assistenza tecnica rivolgersi al proprio rivenditore di zona oppure visitare il sito web Testifire www testifire com Opzione futura AN Q testers www testifire com Testifire 2000 illustrato Informazioni importanti Leggere attentamente il presente manuale dell utente prima di utilizzare il proprio prodotto Testifire
6. annulla la sequenza di test programmata Tasti di navigazione Il tasto freccia GI w presente nell angolo in basso a destra del menu dei menu PRINCIPALE indica le opzioni disponibili elencate di seguito Utilizzare il Tes tasto freccia GI sul tastierino per scorrere il menu verso il basso Invio Fig 17 Tasto ON OFF Tasto Esc Tastierino Il tasto freccia SU nel menu PRINCIPALE indica le opzioni sopra disponibili Utilizzare il tasto freccia SU sul tastierino per scorrere il menu verso l alto Fig 18 Premere il tasto freccia SINISTRA sul tastierino per ornare indietro di un livello di menu CONSIGLIO In caso di un unico test utilizzare i tasti freccia SU e GIU per evidenziare a seconda dei casi le voci Fumo Calore o CO nel menu PRINCIPALE Non necessario premere il tasto INVIO sul tastierino per selezionarli sufficiente lasciare evidenziato lo stimolo richiesto Fig 19 Stato 4 6 Regolazione dell angolazione della testa La corretta angolazione della testa importante per garantire il corretto 8 per 8 posizionamento del rivelatore da testare all interno della tazza trasparente interna e affinch l utente abbia assunto una posizione sicura e appropriata per eseguire il test E necessario che il rivelatore sia a contatto con la base della tazza trasparente interna del dispositivo Testifire e allo stesso liv
7. Non tutto il fumo visibile a occhio nudo pertanto non bisogna pensare che vi sia un problema se non si vede immediatamente il fumo fuoriuscire dall unit La quantit di fumo prodotta pu variare nel corso del test Nel corso di uno smoke test possibile avvertire un leggero scoppiettio durante la produzione di fumo E un rumore normale che fa parte della procedura 5 4 Verifica del calore ATTENZIONE Non avvicinare le mani all uscita dei condotti durante la verifica del calore n nei 5 minuti successivi tale verifica Dal condotto fuoriesce aria calda e la parte superiore del condotto pu essere molto calda Per selezionare un test del calore nel menu PRINCIPALE portare il cursore su Calore utilizzando i tasti SU e GIU 8 sul tastierino Fig 31 Il test inizia automaticamente non appena la testa viene posizionata sopra il rivelatore e il raggio a infrarossi viene bloccato Il LED Tipo di test presente sul dispositivo Testifire si accende di luce rossa a conferma della produzione di calore in corso Il calore viene sospinto nel condotto subito dopo l inizio del test La temperatura dell aria che fuoriesce dal condotto tale da riuscire a scaldare il sensore termico del rivelatore Il calore prodotto forma uno stretto fascio che non viene utilizzato per riscaldare l intera area della tazza trasparente interna del dispositivo Testifire Viene invece riscaldata solo l area immediatamente ci
8. Se non possibile risolvere il problema e far riparare il guasto Ventola Fumo rivolgersi al centro di assistenza di zona e richiedere una riparazione del guasto Modulo Fumo Si verificato un guasto alla ventola del calore Si verificato un guasto al modulo Calore GUASTO GUASTO Rivolgersi al centro di assistenza di zona Se non possibile risolvere il problema e far riparare il guasto Ventola Calore rivolgersi al centro di assistenza di zona e richiedere una riparazione del guasto Modulo Calore Messaggi di errore relativi alle Si verificato un guasto alla ventola CO capsule Fumo e CO GUASTO Se non possibile risolvere il problema La capsula non stata installata rivolgersi al centro di assistenza di zona e Ventola CO richiedere una riparazione del guasto DE Sistemare la capsula se installata oppure installare una nuova capsula Capsula Non Rilevata Si verificato un guasto alla ventola di aspirazione GUASTO Capsula vuota Vet Se non possibile risolvere il problema Aspirazione rivolgersi al centro di assistenza di zona e CO richiedere una riparazione del guasto Installare una nuova capsula Capsula Vuoto Si verificato un guasto alla ventola dello chassis GUASTO La capsula danneggiata o non stata Vee Se non possibile risolvere il problema Corretta mento Chassis rivolgersi al centro di assistenza di zona e 8 capil a
9. charge or disposal The transfer assignment charge or disposal must include all copies of all versions including but not limited to the most recent version of the Software as well as all copies of the Documentation and all accompanying instances of the Licensor s Products 7 3 We may transfer assign charge sub contract or otherwise dispose of this Agreement or any of our rights or obligations arising under it at any time during the term of the Agreement 8 NOTICES All notices given by you to us must be given to No Climb Products Limited at Edison House 163 Dixons Hill Road Welham Green Hertfordshire AL9 7JE We may give notice to you at either the e mail or postal address you provided to us OR our representative when purchasing the Software Notice will be deemed received and properly served immediately when posted on our website 24 hours after an e mail is sent or three days after the date of posting of any letter In proving the service of any notice it will be sufficient to prove in the case of a letter that such letter was properly addressed stamped and placed in the post and in the case of an e mail that such e mail was sent to the specified e mail address of the addressee 9 EVENTS OUTSIDE OUR CONTROL 9 1 We will not be liable or responsible for any failure to perform or delay in performance of any of our obligations under this Agreement that is caused by events outside our reasonable control Force Majeure Event 9 2 A
10. possibile effettuare il test successivo del CO 5 6 Aspirazione del rivelatore Questa operazione prevede il passaggio di aria all interno del rivelatore per azzerarlo Tuttavia questa operazione non pulisce i componenti interni del rivelatore Per selezionare la funzione di azzeramento nel menu principale spostare il cursore sull opzione Elim utilizzando i tasti SU e GIU amp del tastierino Fig 38 L operazione di aspirazione inizia automaticamente quando la testa viene posizionata sopra il rivelatore e il raggio a infrarossi viene bloccato Il LED Stato lampeggia veloce di luce verde o rossa se la batteria scarica Durante l operazione di aspirazione il LED Tipo di test resta sempre spento Suggerimento Impostare Annulla come parte di un test sequenziale con fumo in modo che Fumo corrisponda a I e Annulla corrisponda 2 Fig 39 In questo modo il rilevamento del fumo verr accelerato dal momento che il processo di annullamento eliminer la possibilit che il rilevatore venga riattivato Per i dettagli su come effettuare un test sequenziale vedere la Sezione 5 9 Menu Stato AN gt te S ti fi re www testifire com 17 ar ar 5 an I testi fi r www testifire com 7 Livello di combustibile nelle capsule Per visualizzare sullo schermo il livello residuo di carburante fumo e CO all interno delle capsule evidenziare le opzioni fumo e CO
11. testi fi r e www testifire com Informazioni generali sulla sicurezza ATTENZIONE Il presente prodotto stato concepito per l uso in posizioni elevate Prestare la massima attenzione e indossare sempre un apparecchiatura di protezione personale quando si opera al di sopra dell altezza della testa onde evitare di ferirsi NON SOLLEVARE ECCESSIVAMENTE Mantenere sempre un equilibrio e un appoggio ottimali Un equilibrio e un appoggio in sicurezza garantiscono un migliore controllo del dispositivo in situazioni impreviste Prestare particolare attenzione a non toccare oggetti sopraelevati quali plafoniere cavi di alimentazione barre di distribuzione sopraelevate e qualsiasi altro oggetto che possa staccarsi accidentalmente e mettere in pericolo l operatore o chiunque si trovi nelle vicinanze ATTENZIONE Questo prodotto presenta superfici calde e dai condotti fuoriesce aria calda NON TOCCARE la punta della capsula CO una volta rimossa qualora l unit sia stata in funzione negli ultimi 5 minuti Dopo l uso l unit estremamente calda e se toccata pu causare ustioni NON inserire le dita nella fessura da cui stata rimossa la capsula CO Le superfici sono estremamente calde e se toccate possono provocare ustioni Non avvicinare le mani all uscita dei condotti durante la verifica del calore n nei 5 minuti successivi tale verifica Dal condotto fuoriesce aria calda e la parte superiore del condotto pu essere m
12. a utilizzare nel modo migliore e pi proficuo possibile i prodotti Testifire della serie 1000 e 2000 Il manuale contiene tutte le informazioni necessarie per eseguire senza problemi interventi di manutenzione e di riparazione di routine dispositivi Testifire si avvalgono di una serie di tecnologie avanzate e intelligenti che modificano il tradizionale approccio ai controlli funzionali sul campo Il semplice fatto di poter testare tutti i rivelatori antincendio con un unica unit un operazione pi veloce e produttiva Inoltre la gamma Testifire garantisce vantaggi mai visti prima in termini di salute sicurezza ambiente e tecnologia per l assistenza sul campo dei rivelatori antincendio Il Testifire un dispositivo tecnologicamente avanzato e perfettamente trasportabile per il controllo funzionale dei rivelatori antincendio L unit pu essere utilizzata per il controllo di sensori di fumo ottici fotoelettrici e a ionizzazione sensori termici a temperatura fissa o termovelocimetrici e sensori antincendio di monossido di carbonio CO siano essi tradizionali indirizzabili o indirizzabili analogici Testifire anche il primo tester funzionale a consentire il controllo di rivelatori multisensore o multicriterio utilizzando un unica unit di controllo Il Testifire produce stimoli che i sensori sono progettati per rilevare A seconda del modello acquistato il dispositivo Testifire in grado di generare a richiesta stimoli quali fumo
13. a waiver of such rights or remedies and shall not relieve you from compliance with such obligations 10 2 A waiver by us of any default shall not constitute a waiver of any subsequent default 10 3 No waiver by us of any of these terms and conditions shall be effective unless it is expressly stated to be a waiver and is communicated to you in writing 11 SEVERABILITY If any of the terms of this Agreement are determined by any competent authority to be invalid unlawful or unenforceable to any extent such term condition or provision will to that extent be severed from the remaining terms conditions and provisions which will continue to be valid to the fullest extent permitted by law SRH SM SM 573 4 502256 8 12 ENTIRE AGREEMENT 12 1 This Agreement and any document expressly referred to in it represents the entire agreement between us in relation to the licensing of the Software and Documentation and supersedes any prior agreement understanding or arrangement between us whether oral or in writing 12 2 We each acknowledge that in entering into this Agreement neither of us has relied on any representation undertaking or promise given by the other or be implied from anything said or written in negotiations between us prior to entering into this Agreement except as expressly stated in this Agreement 12 3 Neither of us shall have any remedy in respect of any untrue statement made by the other whether orally or in writing prior to the date we e
14. amp testi fi r e www testifire com 3 Identificazione dei componenti eo Soffietto Capsule sostitutive Capsula TS3 Antenna RFID fumo Testifire Raggio a infrarossi Tazza trasparente interna Condotto principale per calore fumo e CO Capsula TC3 m CO Testifire Piattaforma Ke RFID Testifire 100 Modulo Bluetooth Tazza trasparente Capsula TS3 fumo LED Tipo di test Capsula TC3 Porta USB sul retro dell unit LED Stato Copertura della capsula fumo Testifire 2000 illustrato Display di A seconda delle specifiche del modello interfaccia Opzione futura utente LCD Copertura della capsula CO Tastierino di interfaccia utente Telecomando a raggi infrarossi Tasto Menu Tasto Stato Tasti di navigazione dei menu Impugnatura regolabile asto Invio Tasto ON OFF Tasto Esc Batteria a bastone an 2 testi fi r e www testifire com ar 4 Preparazione per l uso 4 1 Carica delle batterie a bastone AVVERTENZA Non cercare di usare o di caricare la batteriase i punti di collegamento del caricatore o della batteria sono danneggiati Per l alimentazione del dispositivo Testifire vengono utilizzate batterie a bastone NiMH Solo che ne consentono il montaggio su pali Solo Prima di utilizzare il dispositivo Testifire necessario caricare le batterie a baston
15. calore e CO da un unica unit Il dispositivo Testifire genera questi stimoli senza utilizzare contenitori di aerosol pressurizzati o altri mezzi pericolosi Questi stimoli fumo calore e CO vengono generati al momento del test secondo processi sicuri e brevettati che prevedono l impiego di capsule sostituibili Il Testifire pu anche eseguire una serie di test programmati simultanei una qualsiasi combinazione di fumo calore e CO sequenziali ad es fumo seguito da calore e poi da CO o una combinazione di test simultanei e sequenziali ad es fumo e calore insieme seguito poi dal CO Prevede inoltre una modalit di aspirazione che consente l eliminazione degli stimoli subito dopo la conclusione di un test consentendo quindi reset pi rapidi del pannello Il dispositivo Testifire inoltre in grado di leggere e scrivere dati su tag RFID elettronici che possono essere installati sui rivelatori Ci garantisce in certo grado di automazione nel controllo e nella registrazione di attivit di assistenza e manutenzione Il supporto di un modulo opzionale RFID e Bluetooth descritto in dettaglio nel manuale RFID Per ulteriori informazioni o assistenza nell uso del dispositivo Testifire visitare l area dedicata all assistenza sul nostro sito web oppure rivolgersi al nostro reparto di assistenza tecnica i cui dettagli sono indicati nella pagina Assistenza del presente manuale Testifire Serie 1000 Testifire Serie 2000 Testa Testa
16. corrections of errors in source code format as may be provided by the Licensor from time to time Where software is received in source code format clauses 2 I d 2 1 3 2 3 3 shall not apply e use any Documentation in support of the use permitted under condition 1 1 and make copies of the Documentation as are reasonably necessary for its lawful use 2 LICENSEE S UNDERTAKINGS 2 1 Except as expressly set out in this Agreement or as permitted by any local law you undertake a not to copy the Software or Documentation except where such copying is incidental to normal use of the Software or where it is necessary for the purpose of back up or operational security b not to rent lease sub license or loan the Software or Documentation c not to translate merge adapt vary or modify the Software or Documentation d not to make alterations to or modifications of the whole or any part of the Software nor permit the Software or any part of it to be combined with or become incorporated in any other programs e not to disassemble decompile reverse engineer or create derivative works based on the whole or any part of the Software nor attempt to do any such things except to the extent that by virtue of section 296A of the Copyright Designs and Patents Act 1988 such actions cannot be prohibited because they are essential for the purpose of achieving inter operability of the Software with another software program and provided
17. il tipo di test da eseguire automaticamente venga programmato nel tag Ulteriori informazioni saranno pubblicate sul nostro sito appena il modulo di comunicazione Testifire verr lanciato sul mercato www testifire com Antenna RFID RFID Testifire 100 e Modulo Bluetooth 45 te ti fi re www testifire com 21 ar 5 13 Tabella di consultazione dei LED indicativi LED Tipo di test Fumo Calore CO Menu Stato Fumo 1 Calore 1 cop Menu Stato gt Fumo 1 Calore 2 co Stato D TESTER PERRIVELATORE MULTISTIMOLO Luce blu fissa Test del fumo in corso Luce rossa fissa Test del calore in corso Luce verde fissa Test del CO in corso Alternanza di luce rossa blu verde Test di fumo calore e CO in corso contemporaneamente Verifica simultanea Alternanza di luce blu fissa poi rossa verde Test in corso del Fumo seguito da una verifica combinata di Calore e CO Verifica sequenziale Non acceso Modalita di aspirazione in funzione LED Stato Luce verde lampeggiante lenta Modalita STANDBY Luce verde lampeggiante veloce Modalita OPERATIVA test in corso Luce lampeggiante rossa luce rossa lampeggiante lenta in modalita STANDBY e luce lampeggiante rossa veloce durante il funzionamento E necessario ricaricare la batteria Il dispositivo Testifire ancora funzionante ved sezione 4 1 Alternanza di luce rossa verde lampegg
18. infrarossi e il LED Stato riprende a lampeggiare lentamente Il dispositivo Testifire pu essere utilizzato in vari modi per controllare un rivelatore Modalit multistimolo fumo calore CO o in modalit simultanea tutti gli stimoli contemporaneamente e o sequenziale in varie combinazioni Nelle sezioni seguenti vengono descritti i vari stimoli e il relativo metodo di funzionamento amp testi fi r e www testifire com 14 Nota Abbassando il dispositivo Testifire durante un test pu succedere quanto segue Per meno di 2 secondi Nulla 11 test prosegue non appena il rivelatore viene riposizionato nella tazza Per pi di 2 secondi Durante un test sequenziale il dispositivo Testifire passa al test successivo in programma Per pi di 10 secondi Durante un test sequenziale o simultaneo il dispositivo Testifire si resetta e torna al primo test della sequenza di test programmata 5 3 Verifica del fumo Per selezionare uno smoke test nel menu PRINCIPALE spostare il cursore su Fumo utilizzando i tasti SU e GIU 8 del tastierino Fig 30 Il test inizia automaticamente non appena la testa viene posizionata sopra il rivelatore e il raggio a infrarossi viene bloccato II LED Tipo di test presente sul dispositivo Testifire si accende di luce blu a conferma della produzione di fumo in corso Il fumo prodotto viene convogliato all interno del rivelatore dopo pochi secondi dall inizio del test
19. nel menu PRINCIPALE utilizzando i tasti SU e GIU del tastierino Fig 37 quindi premere il tasto INVIO Fig 38 per visualizzare il livello all interno della capsula Fig 39 In caso di esecuzione di un test con una capsula vuota il risultato sar un errore Il LED Stato si accende di luce rossa e sullo schermo compare il messaggio Capsula vuota La presenza di una C accanto alle opzioni fumo o CO nel menu PRINCIPALE indica un problema con la capsula Fig 40 E possibile che la capsula non sia stata installata che si stata installata in modo errato o che sia vuota La presenza di un punto esclamativo accanto alle voci fumo CO indica che la capsula quasi vuota Fig 41 Accertarsi di avere a disposizione dei ricambi Se accanto a Fumo o CO appare il simbolo 1 questo significa che la capsula vuota fig 45 e che dev essere sostituita Stato Fumo MM Menu Stato Liv Capsula 18 5 8 Verifica simultanea L uso del dispositivo Testifire per l esecuzione di un test simultaneo implica la possibilit di pre programmare nell unit una serie di operazioni Fumo Calore e CO prima che questa venga sollevata sul rivelatore Questa possibilit fa risparmiare tempo riduce la manipolazione del dispositivo e consente la verifica di determinati rivelatori multisensore se cos abilitati Nota A seconda del sistema di rilevamento da testare
20. possibile che non vi siano singole indicazioni per l attivazione dei diversi sensori del rivelatore Il sistema pu anche attivare un solo sensore Per programmare uno stimolo per un test simultaneo spostare il cursore sul test desiderato Eeg utilizzando i tasti SU e GIU 8 del tastierino quindi premere il tasto INVIO per selezionare Calore 1 quel test Fig 46 Sullo schermo LCD il test appare con un numero di designazione accanto 2 Dopo il primo indicato dal numero 1 selezionare il secondo stimolo allo stesso modo quindi premere il tasto INVIO una seconda volta e il numero verr modificato in 1 Aggiungere il terzo stimolo allo stesso modo accertando di premere nuovamente il tasto INVIO fin quando accanto a quello stimolo non compare 1 AI termine della procedura accanto a tutti gli stimoli richiesti comparir il numero 1 II LED Tipo di test si accende alternando vari colori a seconda dello stimolo scelto per maggiori dettagli su questi colori ved la sezione 5 13 del presente manuale La fig 47 illustra la procedura di un test simultaneo in questo esempio il test simultaneo di fumo e calore Per annullare l impostazione di un test simultaneo utilizzare il tasto ESC Programmare 2 Sollevare il dispositivo 3 Abbassare il dispositivo i test ay Y Testifire sul rivelatore t l Testifire sul rivelatore Fumo 1 Calore 1 Ne
21. test CO La fig 50 illustra la procedura di un test simultaneo e sequenziale combinato in questo esempio un test Fumo e Calore simultaneo seguito da un test CO Programmare I test ene Smoke 1 Calore 1 Heat 1 gt 0020 CO 2 Menu Status 1 Sollevare il dispositivo Testifire sul rivelatore CO viene testato come secondo test della sequenza allo stesso modo AN festifire ar 2 Sollevare il dispositivo Testifire sul rivelatore t Fumo e Calore vengono testati contemporaneamente come primo test della sequenza 5 Abbassare il dispositivo Testifire sul rivelatore Il test sono terminati e il dispositivo Testifire pronto per testare con la stessa procedura un altro rivelatore i 3 Abbassare il dispositivo Testifire sul rivelatore per 2 10 secondi Il dispositivo Testifire seleziona il test successivo della sequenza in questo caso CO www testifire com 20 5 11 Telecomando a infrarossi Testifire 25 Fascio infrarosso LED Indicatore LED di funzionamento E disponibile un telecomando a infrarossi che consente di accedere all interfaccia utente quando il dispositivo Testifire viene utilizzato in posizioni elevate Grazie a questo telecomando non necessario riportare la testa del dispositivo a livello del suolo per modificare le impostazioni dei test Il telecomando pu essere utilizzat
22. that the information obtained by you during such activities i is used only for the purpose of achieving inter operability of the Software with another software program and ii is not unnecessarily disclosed or communicated without the Licensor s prior written consent to any third party and iii is not used to create any software which is substantially similar to the Software SRH SM SM 573 4 502256 8 f to keep all copies of the Software secure and to maintain accurate and up to date records of the number and locations of all copies of the Software g to supervise and control use of the Software and ensure that the Software is used by your employees and representatives in accordance with the terms of this Agreement h to replace the current version of the Software with any updated or upgraded version or new release provided by the Licensor under the terms of this Agreement immediately on receipt where the Licensor specifically recommends that you do so i to include the copyright notice of the Licensor on all entire and partial copies you make of the Software on any medium j not to provide or otherwise make available the Software in whole or in part including but not limited to program listings object and source program listings object code and source code in any form to any person other than your employees without prior written consent from the Licensor 2 2 You must permit the Licensor and his representatives at all reasonabl
23. 0 Afferrando la capsula per le clip a molla E Fig 10 con l etichetta rivolta verso l alto inserire con cautela la nuova capsula nella rispettiva porta Spingerla in posizione accertandosi che le clip a molla fuoriescano su entrambi i lati della capsula e si incastrino correttamente con la porta Chiudere bene la copertura CO D Fig 9 Fig 10 Clip a molla 4 4 Accensione dell unit Per accendere l unit premere e tenere premuto il tasto rosso ON OFF per 2 secondi Fig I I II LED Stato lampeggia lentamente di luce verde ad indicare che l unit si trova in modalit STANDBY In occasione della prima accensione dell unit 0 dopo un Reset del sistema ved sezione 6 2 viene chiesto di selezionare la lingua operativa del dispositivo Testifire corrispondente al proprio paese Utilizzare i tasti freccia SU e GIU amp per scorrere le varie opzioni e premere il tasto INVIO per selezionare la lingua operativa desiderata Fig 12 Verr visualizzata una schermata di conferma Fig 13 Premere il tasto Deutsch MENU per selezionare o il tasto STATO per annullare l operazione Pesan eee Una volta selezionata la lingua viene visualizzato il menu PRINCIPALE Frangais Italiano Selez Annulla La lingua selezionata pu essere cambiata in qualsiasi momento premendo il tasto MENU Utilizzare i tasti SU e GIU 8 pe
24. E NON TOCCARE il nastro di carbonio nero della capsula CO n l area circostante possibile che dopo l uso la punta e l area circostante siano calde ATTENZIONE NON inserire dita o altri oggetti nell apertura da cui stata rimossa la capsula CO Le superfici sono estremamente calde e se toccate possono provocare ustioni o danneggiarsi Le capsule fumo e CO non sono rabboccabili Sostituirle esclusivamente con capsule TS3 fumo e TC3 CO Testifire originali Nota La garanzia del produttore esplicita in merito al solo utilizzo di ricambi originali Testifire che devono essere sostituiti conformemente alle istruzioni fornite in dotazione Si raccomanda di attenersi alle normative locali vigenti in materia di smaltimento dei materiali di imballaggio batterie scariche e vecchie apparecchiature elettroniche Le capsule vuote possono essere riconsegnate al produttore che nella persona del rivenditore provveder ad uno smaltimento ecocompatibile nel rispetto delle normative WEEE Waste Electrical amp Electronic Equipment 2006 Al momento dell inserimento della capsule applicare solo una leggera pressione Istruzioni per la rimozione delle capsule fumo Testifire serie 1000 e 2000 Aprire la copertura superiore A Fig 7 del dispositivo Testifire dal lato destro Nota Le unit della serie Testifire 1000 dispongono di un unica copertura Premere le due clip B Fig 7 su ciascun lato della cap
25. Force Majeure Event includes any act event non happening omission or accident beyond our reasonable control and includes in particular without limitation the following a strikes lock outs or other industrial action b civil commotion riot invasion terrorist attack or threat of terrorist attack war whether declared or not or threat or preparation for war SRH SM SM 573 4 502256 8 c fire explosion storm flood earthquake subsidence epidemic or other natural disaster d impossibility of the use of railways shipping aircraft motor transport or other means of public or private transport e impossibility of the use of public or private telecommunications networks f the acts decrees legislation regulations or restrictions of any government 9 3 Our performance under this Agreement is deemed to be suspended for the period that the Force Majeure Event continues and we will have an extension of time for performance for the duration of that period We will use our reasonable endeavours to bring the Force Majeure Event to a close or to find a solution by which our obligations under this Agreement may be performed despite the Force Majeure Event 10 WAIVER 10 1 If we fail at any time during the term of this Agreement to insist upon strict performance of any of your obligations under this Agreement or if we fail to exercise any of the rights or remedies to which we are entitled under this Agreement this shall not constitute
26. IO per selezionare Reset Sistema Viene visualizzata una schermata di conferma relativa al Reset Sistema Fig 53 Selezionare Ok premendo il tasto MENU per eseguire il Reset Sistema oppure selezionare Annulla premendo il tasto Stato per annullare un Reset Sistema Tasto Menu Tasto Stato Info Sistema Lingua Reset Sistema Sirena Reset Sistema Ok Annulla In seguito ad un Reset Sistema nella schermata di avvio compare il logo Testifire seguito dall opzione Selezionare la lingua del sistema ved sezione 4 4 amp testi fi r e www testifire com 23 6 3 Messaggi di errore e tabella di consultazione dei LED indicativi Nota In caso di problemi all unit Testifire si accende fissa o lampeggia la spia del LED Stato e il LED Tipo di test spento Sullo schermo viene visualizzato il messaggio di errore Se il LED Stato lampeggia necessario ricaricare o sostituire quanto prima la Si verificato un guasto al modulo CO Sostituire Batteria batteria a bastone GUASTO Modulo CO Rivolgersi al centro di assistenza di zona e far riparare il guasto Se la spia rossa del LED Stato accesa fissa necessario ricaricare o sostituire immediatamente la batteria a bastone Si verificato un guasto alla ventola del fumo Si verificato un guasto al modulo Fumo GUASTO GUASTO Rivolgersi al centro di assistenza di zona
27. Results gt The wizard has finished searching for driver files for your hardware device AJ Found New Hardware Wizard O The wizard onda vr re oloni dv Install Hardware Device Drivers N 8 Testifire device driver is a software program that enables a hardware device to work with AJ an operating system Windows found a driver for this device To install the driver Windows found click Next This wizard will complete the installation for this device Testifire o c program files testifire testifire flash loader usb drivers ftdibus inf device driver is software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the installation click Next What do you want the wizard to do Search for a suitable driver for my device recommended Display a list of the known drivers for this device so that can choose a specific _ Cancel driver lt Back Passo 7 Cliccare su Finish per uscire dal programma Passo 4 Found New Hardware Wizard Selezionare Specify a location e poi fare clic su Next per continuare Completing the Found New Hardware Wizard Found New Hardware Wizard pi Locate Driver Files gt Where do you want Windows to search for driver files AJ gt Testifire Multi Stimulus Detector Tester Windows has finished installing the software for this device Search for driver files
28. age again for this device Your device will not function until you install driver software Se compare la finestra di controllo dell account dell utente con il messaggio Windows necessita e dell autorizzazione continuare selezionare continuare an ur Tes ti fi r e www testifire com 28 Passo 3 Selezionare don t have the disc Show me other options Insert the disc that came with your Testifire H you have the dac that came with your device invert it now Windows will automatically search the dise for driver software Idon thave the disc Show me other options Passo 4 Selezionare Browse my computer for driver software Windows couldn t find driver software for your device gt Check for solution Windows mill check to sce i there are you can take bo get your device Browse my computer for driver software advanced Luske and install dre soia manually Passo 5 I driver USB si trovano nella directory d installazione dell applicazione Testifire Flash Loader Di solito questa si trova in C Program Files Testifire Testifire Flash Loader USB Drivers Utilizzare il comando Browse per selezionare la directory in cui sono localizzati i driver poi cliccare su Next Browse for driver software on your computer Search for driver software im this locations Program Files Teste Testfire Flash Loader USE Drivers in
29. applicazione Testifire Flash Loader JLTI STIMULUS DETECTOR TESTER amp testifire Finish Assistenza tecnica Contatti Nel caso di problemi nell utilizzo di Testifire Flash Loader spedire un email all indirizzo support testifire com Per permetterci di fornire una soluzione rapida e precisa al problema si prega di includere Una descrizione del problema stesso e di come pu essere replicato se pertinente Il sistema operativo utilizzato Vista XP o 2000 e la localizzazione Altre informazioni che potrebbero essere utili Cercheremo di rispondere entro due giorni lavorativi Per ulteriori informazioni visitare www testifire com an gt testifire www testifire com 33 an 8 Specifiche tecniche Alimentazione Tempo di ricarica della batteria Consumo Modalita di test Funzioni di sicurezza Funzioni operative Tipi di rivelatori idonei Dati ambientali Grado di protezione IP Batteria a bastone confezione di batterie ricaricabili NiMH 2 2Ah con tensione nominale 7 2V e dispositivo interno di protezione da sovracorrente che si collega direttamente al Testifire senza cavi n fili Per la caricare utilizzare esclusivamente il caricabatterie Solo 725 100 230 V CA o 12 V CC 75 90 min se completamente scarica A seconda della modalit di utilizzo Verifica CO 2 5 A rms Verifica del calore 4 6 A rms Verifica del fumo lt 0 5 A rms RFID Bluetooth lt 150
30. bsisting in the UK 5 5 This Agreement sets out the full extent of the Licensor s obligations and liabilities in respect of the supply of the Licensor s Products Software and Documentation In particular there are no conditions warranties representations or other terms express or implied that are binding on the Licensor except as specifically stated in this Agreement Any condition warranty representation or other term concerning the supply of the Licensor s Products Software and Documentation which might otherwise be implied into or incorporated in this Agreement or any collateral contract whether by statute common law or otherwise is hereby excluded to the fullest extent permitted by law SRH SM SM 573 4 502256 8 6 TERMINATION 6 1 The Licensor may terminate this Agreement immediately by written notice to you if a You commit a material or persistent breach of this Agreement which you fail to remedy if remediable within 14 days after the service of written notice requiring you to do so or b a petition for a bankruptcy order to be made against you has been presented to the court or c the Licensee where it is a company becomes insolvent or unable to pay its debts within the meaning of section 123 of the Insolvency Act 1986 enters into liquidation whether voluntary or compulsory other than for reasons of bona fide amalgamation or reconstruction passes a resolution for its winding up has a receiver or administrator manag
31. capsule e batterie specificate dal produttore In caso di accumulo di polvere o sporco sulla superficie del prodotto pulire con un panno leggermente umido che non sfilacci Per la pulizia 2 NON BLOCCARE LE NESSUN COMPONENTE T ae BOCCHETTE DI CHE L UTENTE PUO del prodotto non utilizzare detergenti materiali di pulizia o solventi VENTILAZIONE SOTTOPORRE A MANUTENZIONE amp Te S ti fi re www testifire com 25 7 5 Assistenza Affinch il proprio prodotto Testifire funzioni come previsto si consiglia di riconsegnare l unit Revisione con cadenza annuale a scopo di assistenza Necessaria Ved Manuale Prem un Tasto In alcuni paesi Testifire richiede un assistenza annuale documentata conformemente agli standard nazionali o internazionali vigenti in materia di apparecchiature di controllo Fig 53 L assistenza fornita da testers No Climb Products Ltd prevede l impiego di apparecchiature testate conformi 1509001 Revisione Scaduta Ved Manuale dispositivi Testifire dispongono di un timer incorporato che avvisa l utente quando EZIO ERO necessario un intervento di manutenzione Fig 57 o quando questo stato superato Fig 58 Fig 54 In caso di uso intensivo del dispositivo Testifire potrebbe essere necessaria una revisione prima dei 12 mesi Testifire comunicher all utente la necessit o l urgenza di una revisione Se si intende rispedire il Testifire per la manutenzione si prega
32. ch removable media floppy CD ROM Include this location in the search C Program Files T estifire T estifire Flash Loader USE v Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware en amp testifire Passo 5 Questo driver potrebbe non essere ancora crittografato tuttavia ricavabile dal sito www testifire com oppure dal disco fornito con Testifire ed dunque sicuro da utilizzare Selezionare Continue Anyway Hardware Installation The software you are installing for this hardware Testifire Multi Stimulus Detector Tester has not passed Windows Logo testing to verify its compatibility with Windows XP Tell hy thi ing is I Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation Passo 6 A questo punto Windows installera i driver USB Testifire Fare clic su Finish per uscire dal wizard Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Q Testifire Multi Stimulus Detector Tester Click Fin
33. clude subfolders MULTI STIMULUS DETECTOR TESTER Passo 6 Questo driver potrebbe non essere ancora crittografato tuttavia ricavabile dal sito www testifire com oppure dal disco fornito con Testifire ed dunque sicuro da utilizzare Selezionare Install this driver software anyway Don t install this driver software You should check your manufacturer s website for updated driver software for your device gt Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal Passo 7 Windows installer adesso i driver USB di Testifire Fare clic su Close per uscire dal programma di installazione The software for this device has been successfully installed Windows has finished installing the daver software for this device Testifire Multi Stirrutus Detector Tester di Windows XP Driver d installazione per il dispositivo Testifire Passo Lanciare il software Flash Loader e all invito collegare Testifire al computer tramite l apposito cavo USB Il programma di installazione Found New Hardware partir in automatico Passo 2 Windows installera adesso i driver USB di Testifire Fare clic su Close per uscire dal wizard Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on th
34. d as the case may be Warranty Period the Licensor s Products and Software will when properly used perform substantially in accordance with the functions described in the Documentation 4 2 You acknowledge that the Software has not been developed to meet your individual requirements and that it is therefore your responsibility to ensure that the facilities and functions of the Software as described in the Documentation meet your requirements 4 3 You acknowledge that the Software may not be free of bugs or errors and agree that the existence of minor errors shall not constitute a breach of this Agreement 4 4 If within the Warranty Period you notify the Licensor in writing of any defect or fault in the Software in consequence of which it fails to perform substantially in accordance with the Documentation and such defect or fault does not result from you having amended the Software or used it in contravention of the terms of this Agreement the Licensor will at its sole option either repair or replace the Software provided that you make available all the information that may be necessary to help the Licensor to remedy the defect or fault including sufficient information to enable the Licensor to recreate the defect or fault 5 LICENSOR S LIABILITY 5 1 Nothing in this Agreement shall exclude or in any way limit the Licensor s liability for fraud or for death or personal injury caused by its negligence or any other liability to the extent that i
35. di conservare l imballo originale Operazioni compiute per il programma di manutenzione calibratura e controllo della conformit SCCC L unit Testifire viene ispezionata testata e calibrata per assicurarne il pieno funzionamento Questo processo studiato per offrire tranquillit agli utenti di Testifire e per garantire il corretto funzionamento del dispositivo per un anno a partire dal termine del servizio Nella fase di manutenzione eventuali parti usurate a causa del normale utilizzo del dispositivo vengono sostituite Le parti danneggiate sono invece individuate durante l ispezione e il cliente viene informato anticipatamente di eventuali modifiche in modo da poter ottenere l autorizzazione ad effettuare la riparazione oltre alla manutenzione alla calibratura e al controllo di conformit Viene inoltre rilasciato un certificato il Service Calibration and Conformity Certificate a testimonianza del fatto che tutte le misurazioni sono state fatte utilizzando strumenti di calibratura e che sono reperibili presso UKAS National Standards o International Standards ad eccezione dei casi in cui esse non esistano Lo strumento viene inoltre calibrato secondo i requisiti generali ISO 10012 2003 e il sistema di gestione della qualit aziendale ISO 9001 2000 Certificazione BRE Certificato n 813 Conformemente alle esigenze di determinati settori del mercato mondiale i modelli 1000 e 2000 di Testifire dalla versione di firmware 5 4
36. e Solo 760 Per garantire la massima durata di controllo e preservare la vita utile delle batterie caricarle completamente prima del primo utilizzo Per caricare le batterie a bastone Solo 760 utilizzare esclusivamente il caricatore Solo 725 Fig 1 Anello di bloccaggio Testifire Scorpion Battery Charger for E 2 2 Il caricatore 725 pu essere collegato ad una presa di alimentazione di rete ad una presa accessoria auto da 12 volt Una volta collegato all alimentazione di rete o all alimentazione a 12 volt si accende il LED rosso indicante l alimentazione Fig 2 Collegare la batteria a bastone al caricatore mediante il connettore polarizzato a sette poli e ruotare l anello di bloccaggio Fig 3 e 4 Una volta collegata la batteria a bastone si accende il LED giallo di carica rapida Fig 2 tempi di carica dipendono dallo stato di scaricamento della batteria a bastone Per la ricarica di una batteria a bastone completamente scarica possono essere necessari 75 90 minuti Quando la batteria a bastone raggiunge uno stato di carica completa il caricatore Solo 725 passa automaticamente in modalit Trickle Charge Il LED giallo di carica rapida si spegne mentre si accende il LED verde di Trickle Charge CONSIGLIO Quando possibile per garantire alla batteria la massima vita utile lasciare scaricare completamente la batteria a bastone prima di ricaricarla Presso il rivenditore sono disponibili cav
37. e allineato al sensore termico Un allineamento non corretto pu determinare la non riuscita di un test Se dopo 2 minuti il test non terminato il Testifire si disattiva Quando il dispositivo Testifire viene abbassato e si ripristina il fascio a infrarossi passa in modalit STANDBY pronto per eseguire il test successivo Il LED Stato lampeggia lentamente alternando tra rosso e verde per 3 secondi prima di tornare a lampeggiare lentamente solo in verde ad indicare la modalit STANDBY Quando si utilizza l impostazione Calore necessario prestare attenzione a non lasciare la testa del dispositivo Testifire troppo a lungo in posizione su un rivelatore C il rischio che la plastica utilizzata in alcuni rivelatori con elementi di rilevamento termico di tipo velocimetrico o che rispondono a temperature assolute ragionevolmente basse si fonda se esposta al calore per lunghi periodi di tempo Prestare la massima attenzione a non surriscaldare un rivelatore quando si utilizza l impostazione Calore combinata a Fumo e o CO due o pi contemporaneamente in quanto potrebbe verificarsi un ritardo nella risposta da parte del sensore pi lento Ci pu significare che il calore stato applicato pi a lungo del necessario per l attivazione dell elemento del rivelatore NFPA 72 Verifica di un rivelatore di calore Conformemente a NFPA 72 disponibile un opzione timer di 60 secondi Questa opzione cons
38. e hardware installation CD or on the Windows Update Web site with your permission Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device No not this time Click Next to continue Passo 3 Selezionare Install from a list or specified location e poi fare clic su Next per continuare Found New Hardware Wizard This wizard helps you install software for Testifire If your hardware came with an installation CD UE or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Click Next to continue Passo 4 Selezionare Search for the best driver in these locations e Include this location in the search Cliccare su Finish per uscire dal programma di installazione I driver USB si trovano nella directory d installazione dell applicazione Testifire Flash Loader Di solito questa si trova in C Program Files Testifire T estifire Flash Loader USB Drivers Utilizzare il comando Browse per selezionare la directory in cui sono localizzati i driver poi fare clic su Next Found New Hardware Wizard Please choose your search and installation options Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed C Sear
39. e times and on reasonable advance notice to inspect and have access to any premises at which the Software or the Documentation is being kept or used to the computer equipment located there and to any records kept pursuant to this Agreement for the purpose of ensuring that you are complying with the terms of this Agreement 3 INTELLECTUAL PROPERTY RIGHTS 3 1 You acknowledge that all intellectual property rights in the Software and the Licensor s Products and the Documentation anywhere in the world belong to the Licensor that rights in the Software are licensed not sold to you and that you have no rights in or to the Software or the Documentation other than the right to use them in accordance with the terms of this Agreement 3 2 You acknowledge that you have no right to have access to the Software in source code form or in unlocked coding or with comments 3 3 The integrity of this Software or any future upgrade of this software may at any time be protected by technical protection measures TPM so that the intellectual property rights including copyright in the Software of the Licensor are not misappropriated You must not attempt in any way to remove or circumvent any such TPM nor apply or manufacture for sale or hire import distribute sell or let for hire SRH SM SM 573 4 502256 8 offer or expose for sale or hire advertise for sale or hire or have in your possession for private or commercial purposes any means the sole intended purpose o
40. ed materials and related documentation Documentation BY PROCEEDING TO DOWNLOAD ANY SOFTWARE FROM THIS WEBSITE OR INSTALLING THIS SOFTWARE OR CLICKING ON THE ACCEPT BUTTON OR OPENING THE PACKAGING YOU AGREE TO THE TERMS OF THIS AGREEMENT WHICH WILL BIND YOU AND YOUR EMPLOYEES DEFINITIONS Licensor s Products are products that are supplied on commercial terms by the Licensor and with which the Software interacts Website refers to the website from which Licensor makes the Software or upgrades to the software available for download to you I GRANT AND SCOPE OF AGREEMENT I I In consideration of you agreeing to abide by the terms of this Agreement the Licensor hereby grants to you a non exclusive non transferable Agreement to use the Software and the Documentation solely in conjunction with the Licensor s Products on the terms of this Agreement 1 2 You may a download install and use the Software for your private OR internal business purposes only in relation to the Licensor s Products b make copies of the Software where this is necessary for the activities permitted under condition 2 1 a SRH SM SM 573 4 502256 8 c receive and use any free supplementary software code or update of the Software incorporating patches and corrections of errors in non source code format as may be provided by the Licensor from time to time d receive and use any free supplementary software code or update of the Software incorporating patches and
41. ello P P della base del rivelatore Fig 20 Regolare la testa secondo la angolazione corretta per accedere al rivelatore da testare Afferrare il corpo del Testifire e facendo delicatamente leva sulla molla angolare la testa in direzione opposta rispetto alla batteria a bastone Fig 21 La testa dovr essere libera di ruotare nella posizione desiderata dave noi si hlaccher e tale rester durante l utilizzo Fig 22 AN p te S ti fi re www testifire com ar 4 7 Verifica dei rivelatori ad alto profilo Quando si controllano rivelatori ad alto profilo potrebbe essere necessario rimuovere la tazza trasparente interna per consentire il corretto posizionamento del rivelatore ai fini di un buon esito del test La tazza trasparente interna presenta una fessura semicircolare sul lato pi vicino all interfaccia utente Inserire un dito nella fessura e sollevare delicatamente la tazza Fig 23 Questa operazione consentir il corretto posizionamento del rivelatore ad alto profilo all interno della tazza Fig 24 D TESTER PERRIVELATORE MULTISTIMOLO 5 Uso del dispositivo Testifire ATTENZIONE Il presente prodotto stato concepito per l uso in posizioni elevate Prestare la massima attenzione e indossare sempre un apparecchiatura di protezione personale quando si opera al di sopra dell altezza della testa onde evitare di ferirsi NON SOLLEVARE ECCESSIVAMENTE Mantenere sempre un equilibrio e un appoggio
42. ente di interrompere il test del calore dopo 60 secondi come previsto dallo standard L opzione Timer disponibile per le impostazioni Calore e Calore Per selezionare l opzione Timer evidenziare le impostazioni Calore o nel menu PRINCIPALE Premere il tasto STATO Fig 34 e spostare il cursore utilizzando i tasti SU e GIU del tastierino per evidenziare la voce Timer nel menu Fig 35 Per la selezione premere il pulsante INVIO sul tastierino Nel menu PRINCIPALE compare un icona del countdown accanto alle voci Calore o Calore Fig 36 Una volta selezionata l opzione timer questa resta attiva fin quando non viene disattivata manualmente o fin quando non avviene un Reset del Sistema ved sezione 6 2 Stato Calore Fumo Calore On Calore gt Timer Off eH Stato AN y te S ti fi re www testifire com 16 far 5 5 Verifica del monossido di carbonio CO AVVERTENZA Questo prodotto produce piccole quantita di monossido di carbonio CO un gas pericoloso e inodore NON INALARE direttamente l aria che fuoriesce dal condotto durante un test CO n entro i 5 minuti successivi tale controllo Nota in normali condizioni di utilizzo la quantit di CO prodotta non dannosa per l utente Per ulteriori informazioni fare riferimento alle informazioni sulla sicurezza fornite a parte Per selezionare un test CO
43. er trustee liquidator or similar officer appointed over the whole or any part of its assets makes any composition or arrangement with its creditors or takes or suffers any similar action in consequence of its debt unable to pay your debts within the meaning of section 123 of the Insolvency Act 1986 6 2 Upon termination for any reason a all rights granted to you under this Agreement shall cease b you must cease all activities authorised by this Agreement c you must immediately pay to the Licensor any sums due to the Licensor under this Agreement and d you must immediately delete or remove the Software from all computer equipment in your possession and immediately destroy or return to the Licensor at the Licensor s option all copies of the Software then in your possession custody or control and in the case of destruction certify to the Licensor that you have done so AN 7 Tes ti fi r e www testifire com 38 7 TRANSFER OF RIGHTS AND OBLIGATIONS 7 1 This Agreement is binding on you and us and on our respective successors and assigns SRH SM SM 573 4 502256 8 7 2 You may transfer assign charge or otherwise dispose of this Agreement or any of your rights or obligations arising under it without our prior written consent provided that the beneficiary of any such any transfer assignment charge or disposal must have agreed to abide by the terms of this Agreement prior to or at the time of any such transfer assignment
44. erito all uso di informazioni contenuti in questi materiali scritti o software per danni imputabili all uso di informazioni ivi contenute No Climb Products Ltd Edison House 163 Dixons Hill Road Welham Green Hertfordshire AL9 7JE United Kingdom detectortesters testing technology from No Climb
45. escindere dal fatto che siano in uso o meno nei luoghi elencati di seguito e Luoghi dove le temperature e o l umidit sono elevate o soggette a estreme variazioni Luce diretta del sole o in prossimit di fonti di calore forni radiatori ecc Attenersi sempre alle restrizioni in materia di ambienti di utilizzo e di stoccaggio riportate in dettaglio alla voce Specifiche tecniche ved sezione 9 e In ambienti in cui presente sabbia o polvere e In luoghi soggetti a forti vibrazioni e In prossimit di fonti di onde radio o statiche e Ambienti umidi o bagnati dispositivi Testifire sono concepiti per il solo uso indoor Interrompere immediatamente l uso del Testifire qualora dal dispositivo provengano odori liquidi o rumori insoliti Spegnere immediatamente il dispositivo e richiedere assistenza tecnica sezione 7 1 Se il dispositivo Testifire si danneggia non utilizzarlo Spegnere immediatamente il dispositivo e richiedere assistenza tecnica sezione 7 1 Il dispositivo Testifire non stato concepito per l uso in aree pericolose quelle dove sono presenti vapori o polveri esplosive Utilizzare esclusivamente accessori a norma raccomandati dal produttore del proprio modello di dispositivo Testifire Rimuovere la batteria a bastone quando il dispositivo Testifire non in uso In questo modo si previene il graduale scaricamento della batteria e una potenziale attivazione accidentale della testa del dispositivo Non util
46. estifire deve essere collegato unicamente a personal computer conformi alle norme sulla sicurezza e alla compatibilit elettromagnetica EMC in vigore Utilizzare unicamente il cavo USB 2 0 in dotazione al Testifire per il collegamento dell unit ad un personal computer PC abilitato USB gt Info Sistema Gli aggiornamenti del firmware disponibili all indirizzo http www testifire com site technical Lingua possono essere caricati sulla propria unit Testifire utilizzando l applicazione Testifire Flash Loader RR disponibile anch essa su www testifire com Per istruzioni sulle modalit d uso vedere il file di help del Testifire Flash Loader Fig 55 L Accordo di licenza con l utente finale EULA per Testifire Flash Loader si trova alla Sezione 10 Testifire 2100 123456 V3 2 7 3 Informazioni sul sistema V1 0 Per visualizzare le informazioni sul sistema accendere l unit utilizzando il tasto on orr Premere il tasto MENU per visualizzare il menu e utilizzare i tasti SU e GIU amp per individuare la voce Info Sistema Fig 55 Premere il tasto INVIO per accedere al menu relativo alle informazioni sul sistema Fig 56 Premere il tasto ESC per tornare al menu 7 4 Manutenzione Il dispositivo Testifire non presenta parti che l utente possa sottoporre a manutenzione Non smontare il dispositivo Non bloccare le bocchette di ventilazione Utilizzare esclusivamente
47. estifire sul rivelatore Il test Calore il secondo della sequenza ad essere eseguito Lower Testifire from the detector The tests are completed and Testifire is ready to test another detector in the same way 2 Sollevare il dispositivo Testifire sul rivelatore Ha inizio il test Fumo 5 Abbassare il dispositivo Testifire sul rivelatore per 2 10 secondi Il dispositivo Testifier seleziona il test successivo della sequenza in questo caso CO Per cancellare una sequenza di test premere il tasto ESC 5 10 Verifica simultanea e sequenziale combinate 3 Abbassare il dispositivo Testifire sul rivelatore per 2 10 secondi I Il dispositivo Testifire p seleziona il test successivo della sequenza in questo caso Calore Sollevare il dispositivo Testifire sul rivelatore Il test CO il terzo della sequenza ad essere eseguito Se necessario con il dispositivo Testifire possibile selezionare una combinazione di test simultanei e sequenziali Utilizzando i metodi sopra descritti possibile programmare nell unit una serie di combinazioni Nell esempio riportato di seguito Calore e Fumo vengono combinati come prima operazione seguiti poi dal test CO Nota anche in questo caso necessario abbassare la testa del dispositivo per 2 secondi al termine dei test Fumo e Calore e poi risollevarla per dare inizio al
48. f which is to facilitate the unauthorised removal or circumvention of such TPM 6 Tes ti fi r e www testifire com 37 3 INTELLECTUAL PROPERTY RIGHTS 3 1 You acknowledge that all intellectual property rights in the Software and the Licensor s Products and the Documentation anywhere in the world belong to the Licensor that rights in the Software are licensed not sold to you and that you have no rights in or to the Software or the Documentation other than the right to use them in accordance with the terms of this Agreement 3 2 You acknowledge that you have no right to have access to the Software in source code form or in unlocked coding or with comments 3 3 The integrity of this Software or any future upgrade of this software may at any time be protected by technical protection measures TPM so that the intellectual property rights including copyright in the Software of the Licensor are not misappropriated You must not attempt in any way to remove or circumvent any such TPM nor apply or manufacture for sale or hire import distribute sell or let for hire SRH SM SM 573 4 502256 8 offer or expose for sale or hire advertise for sale or hire or have in your possession for private or commercial purposes any means the sole intended purpose of which is to facilitate the unauthorised removal or circumvention of such TPM 4 WARRANTY 4 1 The Licensor warrants that For a period of 90 days from the date of purchase installation or downloa
49. ffietto max 153mm Altezza della testa max 273 mm 397 mm compresa l impugnatura Nota le specifiche dei prodotti possono essere soggette a variazioni senza alcun preavviso od obbligo da parte del produttore Brevetti internazionali Testifire protetto dai seguenti brevetti e dispone di brevetti validi Brevetti EP FR GB 091055B DE69820382 8 ZL98 120414 7 US6423962 EP FR GB I 290661B DE60112442 1 ZL01801074 1 056640608 HK1065150 EP FR GB 1390927B DE50205 I 16 7 DE60314594 9 GB2385179B GB2409319B Brevetti validi per US10 503745 EP1794728A WO 2007 015045 WO 2007 060447 GB2432703A 8 1 Ricambi disponibili per la sostituzione sul campo Per il dispositivo Testifire si consiglia l utilizzo esclusivo di accessori raccomandati dal produttore vedere sezione 9 D te S ti fi re www testifire com 35 ar 9 Sistema di selezione prodotti Prodotti Applicazione Accessori Accesso Fumo Fumo Carica Attrezzo Valigetta di Altezza Altezza Fumo Calore CO Calore Calore ASD batteria batterie universale per transporto di accesso di accesso Verifica Verifica Verifica Verifica CO Verifica Verifica a bastone rapido la rimozione protettiva finoa6m finoa9m i al testifire an a testifire 2000 testifire TS3 testifire TC3 cm is testifire 22 1001 o pes a 2 L testifire
50. fire Perch sono necessari gli aggiornamenti Un aggiornamento Testifire Firmware pu fornire una funzionalit supplementare e o un potenziamento delle funzionalit esistenti Requirements Il Software Testifire Flash Loader Cavo USB Testifire da A a mini B Codice EA36176 Batteria completamente carica Connessione ad Internet Supportato da Windows 2000 Professional Windows XP x32 Windows Vista x32 USB VI I and USB V2 0 Testifire Flash Loader dotato di una funzione automatica che consente di collegare lo strumento ad internet e di scaricare le ultime versioni del firmware di Testifire E necessaria la connessione ad internet Gli utenti avanzati possono scaricare manualmente un file binario del firmware Testifire ed aggiornare il sistema anche senza l accesso ad internet Windows Vista Installazione del driver per il dispositivo Testifire Passo gt Found New Hardware Lanciare il software Flash Loader e dopo l invito connettere Testifire al computer tramite l apposito cavo Windows needs to install driver software for your Testifire USB fornito Windows will guide you through the process of installing driver software for your device Il programma di installazione Found New Hardware partir in automatico Passo 2 gt Ask me again later Windows will ask again the next time you plug in your device or log on Selezionare Locate and install driver software i Don t show this mess
51. for the following hardware device o Testifire The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify To start the search click Next If you are searching on a floppy disk or CD ROM drive insert the floppy disk or CD before clicking Next Optional search locations To close this wizard click Finish I Floppy disk drives CD ROM drives grecevanvecnrevavecsvoneneasreasseanesenrey Microsoft Windows Update lt Back Cancel AN ND Tes ti fi r e www testifire com 31 UAggiornamento del Firmware per il Testifire Prima di collegare Testifire al computer installare il software Flash Loader Passo Dopo l installazione del software Testifire Flash Loader lanciare l applicazione dal men dei programmi o dall icona sul desktop Testifire Flash Loader amp testifire Testifire Flash Loader Yersion 1 00 Testifire Firmware Upgrade Utility 2008 No Climb Products Ltd All rights reserved To continue click Next http www testifire com Passo 2 Inserire all interno di Testifire una batteria completamente carica Testifire Flash Loader Insert a fully charged battery and then switch the unit on To continue click Next Passo 3 Collegare il cavo USB a Testifire e successivamente al computer Se i driver del dispositivo Testifire non erano stati installati precedentemente il comp
52. he Testifire Firmware update process Non interrompere la programmazione n scollegare il cavo USB Comparir la barra di progressione Testifire Flash Loader Testifire Firmware update in progress Please wait DO NOT DISCONNECT Quando la programmazione viene completata con successo sara visualizzata la schermata seguente Fare clic su Next per procedere Testifire Flash Loader Your Testifire Firmware has been updated to 5 2 It is safe to disconnect Testifire from the computer 100 To continue click Next Nell improbabile eventualit che il processo di programmazione non venga portato a termine con successo o che la programmazione venga interrotta dall utente Testifire rimarra in modalita Boot Loader Fare clic su Cancel per uscire dal programma Scollegare il cavo USB e la batteria a bastone da Testifire Il processo pu ricominciare dal Passo Testifire rimarr in modalit Boot Loader fino a che la programmazione non sar completata con successo e non pu essere danneggiato in modo permanente durante il processo Quando Testifire alimentato in modalit Boot Loader lo schermo rimane vuoto e viene emesso un doppio segnale acustico Questo segnale indica che Testifire funziona e che pu essere programmato normalmente a partire dal Passo Passo 7 Selezionare Finish per uscire dall
53. i continuare a funzionare ma se l errore non stato corretto molto probabile che il messaggio di errore ricompaia immediatamente sullo schermo LCD Per poter procedere necessario correggere l errore Se ad esempio la batteria completamente scarica sullo schermo LCD compare il messaggio Sostituire Batteria In una situazione simile non possibile condurre altri test fin quando la batteria a bastone non sar stata ricaricata o sostituita La sezione 6 3 riporta un elenco completo dei messaggi di errore visualizzati sullo schermo e i colori dei LED indicativi Per i messaggi di errore RFID consultare il manuale RFID sul sito www testifire com 6 2 Reset del sistema Se nonostante essersi attenuti alle indicazioni di cui sopra il problema persiste eseguire un Reset Sistema che riporti l unit Testifire alle impostazioni predefinite di fabbrica Un Reset Sistema rimuove tutte le impostazioni utente personalizzabili tra cui Cancellazione di tutte le sequenze di test programmate Disattivazione dell opzione Timer Attivazione dei segnali acustici Avviso e Tastierino Ripristino della funzione Calore in caso di selezione dell opzione Calore Rimozione della lingua selezionata Per eseguire un Reset Sistema premere il tasto MENU del tastierino Fig 51 e utilizzare i tasti SU e GIU 8 per individuare la voce Reset Sistema Fig 52 Premere il tasto INV
54. i di alimentazione internazionali Nota non utilizzare batterie a bastone NiCad Solo 4 2 amp testi fi r e www testifire com ar AN 4 2 Inserimento della batteria ATTENZIONE Inserendo la batteria nell attrezzo verificare che l orientamento sia corretto Non forzare Per inserire la batteria a bastone nel dispositivo Testifire sostenere la testa del dispositivo Testifire per l impugnatura e premere il pulsante a molla superiore della batteria Allineare il pulsante al foro di posizionamento presente sull impugnatura e spingere la batteria all interno dell impugnatura fin quando il pulsante non si inserisce nel foro di posizionamento Fig 5 CONSIGLIO Una leggera rotazione della batteria a bastone pu agevolare l allineamento al momento dell inserimento Inserire l altra estremit della batteria nel palo Solo e premere il pulsante a molla inferiore Allinearlo al foro di posizionamento e spingere ulteriormente la batteria a bastone all interno del palo fin quando il pulsante non si inserisce nel foro Fig 6 gt te S ti fi re www testifire com 4 3 Rimozione e sostituzione delle capsule fumo e CO Monossido di carbonio ATTENZIONE Questo simbolo presente sul prodotto indica che questa parte del dispositivo soggetta a danni statici NON TOCCARE i contatti sulla PCB della capsula L elettricit statica pu danneggiarli ed necessario evitare la contaminazione dei contatti ATTENZION
55. i ma non oltre i 10 secondi ripristinando il fascio a infrarossi in modo che possa passare al test successivo ved Fig 47 3 Esempio Per la verifica Fumo seguita da Calore e poi CO il dispositivo Testifire viene sollevato sul rivelatore che interrompe il fascio a infrarossi Ha inizio il test Fumo Il test d esito positivo 0 negativo dopo la disattivazione del Testifire Abbassare la testa del dispositivo per 2 secondi in modo che il rivelatore sia staccato dalla tazza trasparente e dal soffietto quindi sollevarlo nuovamente per dare inizio al test Calore Ripetere la stessa procedura per il test CO Durante un test sequenziale necessario rimuovere il rivelatore dalla tazza per pi di 2 secondi al fine di consentire al dispositivo Testifire di passare al test successivo della sequenza programmata Se il rivelatore non viene reinserito nella tazza entro 10 secondi la sequenza di test si resetta e il dispositivo torna al primo test della sequenza programmata an 97 testi fi r e www testifire com 19 A questo punto automaticamente pronta un altra identica sequenza di test e non necessario riselezionare il test sul tastierino La fig 49 illustra la procedura di un test sequenziale in questo esempio si tratta del test Fumo seguito da Calore e quindi CO Programmare I test ae Smoke 1 Calore 2 Heat 2 4 Stato J Sollevare il dispositivo T
56. i preme il pulsante di accensione e un qualsiasi tasto Tastierino e un segnale oN e IStema acustico pi lungo della durata di 2 secondi in caso di errori Avviso In alcuni ambienti il sirena potrebbe non essere indicato Il Testifire dispone di un opzione che consente di disabilitare entrambi i tipi di segnali acustici Una volta disabilitato il sirena resta disabilitato fin quando non viene riabilitato manualmente o in caso di un Reset Sistema ved sezione 6 2 x Sirena Per disabilitare il sirena premere il tasto MENU e utilizzando i tasti SU e GIU G del Tastierino Off tastierino selezionare Sirena Fig 26 con il tasto INVIO Utilizzare il tasto INVIO se A anche per selezionare lo stato ON oppure OFF dell avviso acustico per le voci Tastierino e Avviso Fig 27 5 2 Verifica di un rivelatore Sollevare il Testifire fino al rivelatore da testare e posizionarlo centralmente sul rivelatore Nel momento in cui il rivelatore entra all interno della tazza trasparente e blocca il sensore a infrarossi incorporato presente nella testa del Testifire hanno inizio i test selezionati o la sequenza di test Nota Affinch il test dia risultati soddisfacenti estremamente importante che il rivelatore sottoposto al test si trovi nella giusta posizione all interno della tazza trasparente Il rivelatore deve essere appoggiato sulla piattaf
57. iante Indicazione di TIME OUT dopo 2 minuti di verifica continua di uno stimolo o di una combinazione di stimoli Luce rossa fissa Errore ved messaggio sul display ved sezione 6 1 Alternado verde lampeggi Fase di raffreddamento della CO indicazione dopo l esecuzione di un test su sulla CO Finche il LED di stato indica la modalita di STANDBY Non e possible l esecuzione di ulteriori test sulla CO 6 Risoluzione guasti In caso di problemi con il Testifire spegnere il dispositivo attendere alcuni secondi e poi riaccenderlo In questo modo il guasto dovrebbe essere stato risolto Se il guasto persiste le seguenti informazioni potrebbero aiutare l utente a risolvere il problema Qualora non sia possibile risalire alla causa del problema rivolgersi al centro di assistenza regionale 6 1 Errori Quando si verifica un errore si accende la spia rossa del LED Stato e il LED Tipo di test spento Questa situazione chiaramente visibile senza dover accedere allo schermo LCD quando l unit viene utilizzata in posizioni elevate L unit emette un segnale acustico di 2 secondi se stato abilitato il segnale acustico in caso di Avviso e smette di funzionare Sullo schermo LCD viene visualizzato un messaggio di errore ved sezione 6 3 In alcuni casi possibile cancellare il messaggio di errore dallo schermo LCD premendo il tasto ESC del tastierino A volte ci consente all unit d
58. imb Products Ltd Tutti i diritti riservati 1 3 Riciclo L imballo pu essere facilmente scomposto nei seguenti materiali Cartone scatola esterna Cartone divisori interni scatole Polietilene custodie delle capsule Plastica custodie delle capsule Smaltire ciascun materiale conformemente ai requisiti ambientali locali vigenti Normative WEEE Waste Electrical amp Electronic Equipment Rifiuti di apparecchiature elettriche ed elettroniche 2006 Il dispositivo e le capsule Testifire sono appositamente contrassegnati per il riciclo conformemente ai requisiti ambientali locali vigenti In alternativa possibile riconsegnare questi articoli al produttore tramite il proprio rivenditore affinch li smaltisca conformemente alle Normative WEEE Waste Electrical amp Electronic Equipment 2006 Dichiarazione RoHS Con la presente dichiariamo che questo prodotto e i suoi componenti sono progettati e prodotti nel pieno rispetto dei requisiti della Direttiva 2002 95 CE sulle restrizioni d uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche Direttiva RoHS EULA Accordo di licenza con l utente finale Vedere Sezione 10 amp Te S ti fi re www testifire com 4 2 Introduzione Grazie per aver acquistato il tester per rivelatore multistimolo Testifire Grazie per aver acquistato il tester per rivelatore multistimolo Testifire Lo scopo del presente manuale aiutare l utente
59. in poi permettono ora di spegnere gli schermi della notifica di Manutenzione Chi utilizzasse una versione precedente del firmware e volesse scegliere quest opzione dovr aggiornare il firmware di Testifire Per dell ulteriori informazioni sugli aggiornamenti del firmware di Testifire vedere http www testifire com site technical Perch dovrei rispedire il dispositivo per la manutenzione la calibratura e il controllo di conformita Si prega di restituire il dispositivo Testifire le batterie bastone e il caricatore non sono coperti da questo servizio Si prega di includere la coppa interna di Testifire Rispedire il dispositivo Testifire e le parti elencate qui sopra al proprio rivenditore G5 te S ti fi re www testifire com 26 7 6 Promemoria di servizio Come opzione predefinita Testifire notificher all utente le manutenzioni dovute e la loro scadenza Il servizio di promemoria pu essere disattivato dalla versione di firmware 5 4 in poi Per disattivare il servizio di promemoria selezionare MENU sul tastierino e navigare con a il tasto GIU fino a selezionare Servizio Fig 61 Digitare il tasto INVIO per Lingua Sirena selezionare Servizio Questo apre lo schermo di controllo del servizio di promemoria Reset Sistemaw Fig 62 Premere INVIO per disattivare il servizio di promemoria gt lt Attenzione La possibilita di disattivare gli schermi del ser
60. ish to close the wizard Finish www testifire com 30 Windows 2000 Driver d installazione per il dispositivo Testifire Passo Passo 5 Lanciare il software Flash Loader e all invito selezionafe Specify a location quindi fare clic su Next per connettere Testifire al computer I driver USB si trovano nella directory d installazione dell applicazione tramite l apposito cavo USB Testifire Flash Loader Il programma di installazione Found New Hardware partir in automatico Di solito questa si trova in C Program Files Testifire Testifire Flash Loader USB Drivers Passo 2 Utilizzare il comando Browse per selezionare la directory in cui sono Fare clic su Next per continuare localizzati i driver poi cliccare su OK Found New Hardware Wizard Found New Hardware Wizard Insert the manufacturer s installation disk into the drive OK selected and then click OK Welcome to the Found New ey Hardware Wizard I This wizard helps you install a device driver for hardware device Copy manufacturer s files from C Program Files T estifire T estifire Flash Loader U To continue click Next Passo 6 lt Back Il driver Testifire dovrebbe essere identificato Fare clic su Next per Passo 3 procedere all installazione Selezionare Search for a suitable driver for my device e poi fare clic su Found New Hardware wizard N ext per ntin uare Driver Files Search
61. izzare il dispositivo Testifire in caso di funzionamento non ottimale Consultare la sezione Risoluzione guasti sezione 6 0 del presente manuale e se necessario richiede una consulenza tecnica amp testi fi r e www testifire com Significato di simboli e termini Nel manuale dell utente vengono utilizzati i seguenti simboli Questo simbolo presente sul prodotto indica la presenza di un pericolo per la sicurezza A tale proposito necessario leggere le sezioni appropriate del manuale dell utente che aiutano a comprendere la natura e la gravit di tutti i potenziali pericoli e le misure da adottare Questo simbolo indica la necessit di leggere e comprendere quanto riportato nel manuale dell utente prima di utilizzare il prodotto Questo simbolo presente sul prodotto avverte l utente della presenta di superfici calde o di calore per convezione Questo simbolo presente sul prodotto indica che questa parte del dispositivo soggetta a danni statici Il simbolo barrato del contenitore dei rifiuti presente sul prodotto o nella documentazione ad esso relativa indica il divieto di smaltimento del dispositivo unitamente ad altri rifiuti aziendali al termine della sua vita utile Al fine di garantire il riutilizzo e il riciclo di risorse preziose e di prevenire potenziali danni all ambiente o alla salute umana imputabili ad uno smaltimento incontrollato dei rifiuti separare il dispositivo da qualsiasi altro tipo di rifiuto amp
62. l test simultaneo Il test concluso e il J Viti Calore 1 4 CO verranno testati dispositivo Testifire LL ME stato contemporaneamente pronto per testare allo fumo e calore stesso modo un altro Fig 47 rivelatore 5 9 Verifica sequenziale L uso del dispositivo Testifire per l esecuzione di un test sequenziale implica la possibilit di pre programmare nell unit una serie di operazioni Fumo Calore CO e Aspirazione prima che questa venga sollevata sul rivelatore Questa possibilit fa risparmiare tempo riduce la manipolazione del dispositivo e consente la verifica di determinati rivelatori multisensore se cos abilitati Una o tutte le suddette modalit di test Fumo Calore CO Aspirazione o una combinazione simultanea possono essere programmate in una breve sequenza di test di max quattro elementi Per programmare le sequenze spostare il cursore sul test desiderato utilizzando i tasti SU e RE GI amp del tastierino quindi premere il tasto INVIO per selezionare quel test Fig 48 caa Sull LCD il primo stimolo aggiunto in questo modo apparir con il numero di designazione 1 accanto Si sceglie poi allo stesso modo lo stimolo successivo che sar indicato dal numero 2 e cos via Menu Stato Per poter passare da un test all altro di una sequenza necessario abbassare leggermente il dispositivo Testifire per almeno 2 second
63. mA rms N B Il consumo energetico si riferisce esclusivamente alla durata effettiva del test e pu variare sensibilmente a causa di algoritmi di controllo interni Calore normale per testare rivelatori di calore termovelocimetrici e a temperatura fissa fino a 90 C 194 Caloret per testare rivelatori di calore termovelocimetrici e a temperatura fissa fino 100 C 212 F Fumo simulazione di fumo prodotto all interno del dispositivo utilizzando uno scambiatore di calore in miniatura e un liquido innocuo dalla capsula fumo Monossido di carbonio CO il CO viene prodotto all interno del dispositivo e spinto all interno del rivelatore ad una concentrazione di circa 100 ppm non calibrati IL MONOSSIDO DI CARBONIO CO UN GAS NOCIVO E INODORE OCCORRE PERTANTO PRESTARE ATTENZIONE A NON INALARE DIRETTAMENTE L ARIA CHE FUORIESCE DA CONDOTTO DURANTE UN TEST CO Aspirazione aria pulita viene convogliata nel dispositivo per rimuovere eventuali residui di fumo o CO utilizzati in precedenza Verifica simultanea In un unico test viene verificata la presenza di fumo calore e CO se pertinente in qualsiasi combinazione secondo quanto programmato dall utente Verifica sequenziale test vengono eseguiti nell ordine in cui sono stati programmati dall utente Modalit automatica RFID verifica automatica mediante l uso di un modulo RFID montato nel dispositivo Testifire e un etichetta RFID adeguatamente programmata affissa sul rivelato
64. mazioni sulla sicurezza fornite a parte AI termine delle procedure di preparazione il Testifire pronto per essere utilizzato Per eseguire un semplice test con un unico stimolo utilizzare i tasti SU e GI 8 del tastierino come descritto nella sezione 4 4 del presente manuale per evidenziare lo Fumo stimolo richiesto Fig 25 Sebbene sia possibile selezionare lo stimolo richiesto Fs premendo il tasto INVIO per eseguire un test con un unico stimolo sufficiente Menu Stato evidenziare lo stimolo richiesto le sequenze complesse di test con un unico stimolo test multistimolo simultanei vengono trattati nelle sezioni 5 8 5 9 e 5 10 ad amp testi fi r e www testifire com 13 Una volta selezionato lo stimolo il LED Tipo di test cambia colore ad indicare quanto segue Rosso Test del calore Blu Test del fumo Verde Test del monossido di carbonio Trasparente Aspirazione II LED Stato fornisce il feedback sulle modalit di funzionamento e avverte l utente di eventuali errori o se una capsula fumo o CO vuota o stata montata in modo errato La tabella di consultazione dei LED indicativi riporta nel dettaglio tutte le possibili variazioni ved sezione 5 13 5 1 Opzione sirena s e gd de Info Sistema Il dispositivo Testifire emette due diversi tipi di segnali acustici Un segnale acustico breve 8 8 Lingua quando s
65. nel menu PRINCIPALE spostare il cursore sull opzione CO utilizzando i tasti SU e GI del tastierino Fig 37 Il test inizia automaticamente non appena la testa viene posizionata sopra il rivelatore e il raggio a infrarossi viene bloccato Il monossido di carbonio un gas invisibile per cui la presenza del gas durante un test Lui da sr n i non evidente Il LED Tipo di test presente sul dispositivo Testifire si accende di luce aie verde a conferma della presenza di CO CO Menu Stato Una volta prodotto il CO viene convogliato nel rivelatore Quando utilizzato conformemente alle istruzioni il dispositivo Testifire pu essere impiegato nella massima sicurezza per il controllo di rivelatori antincendio e di CO Questo dispositivo non invece indicato per il controllo della maggior parte dei rivelatori di CO Life Safety la cui attivazione richiede in genere un esposizione di gran lunga superiore al monossido di carbonio Dopo aver testato la presenza di CO singolarmente o come parte di un programma Testifire raffredda l elemento di riscaldamento del CO L indicatore luminoso verde a LED sulla parte destra del dispositivo lampegger rapidamente e sar seguito da una luce rossa ad intermittenza con intervalli pi lunghi Quando la temperatura dell elemento di riscaldamento del CO scesa l indicatore a LED indicher la modalit di STANDBY con un lento lampeggio verde A questo punto
66. ntered into this Agreement unless such untrue statement was made fraudulently and the other party s only remedy shall be for breach of contract as provided in these terms and conditions 13 LAW AND JURISDICTION This Agreement is governed by English law Any dispute arising from or related to any term of this Agreement shall be subject to the exclusive jurisdiction of the courts of England and Wales AN 7 Tes ti fi r e www testifire com 39 Alla luce della nostra politica improntata al continuo miglioramento i dettagli dei prodotti descritti nel presente manuale sono soggetti a variazioni senza preavviso Tutte le informazioni fornite in questa sede sono ritenute corrette al momento della stampa E stato fatto il possibile per garantire l esattezza delle informazioni fornite in buona fede Tuttavia si presume che nulla di quanto qui riportato costituisca un eventuale dichiarazione o garanzia sia essa espressa o implicita n rappresenti la base di eventuali rapporti giuridici aggiuntivi o in luogo di questi tra le parti qui citate nella maniera in cui possono essere validi per un contratto di vendita o acquisto Avviso sul copyright Tutti i diritti riservati vietata la riproduzione anche parziale o l uso in qualsiasi forma e mezzo elettronico o meccanico di questi materiali scritti compresa la fotocopiatura senza previo consenso scritto di detectortesters No Climb Products Ltd Non si assume nessuna responsabilit in m
67. o anche per selezionare manualmente ogni singolo test piuttosto che lasciare che sia la testa del dispositivo ad avviare automaticamente un test quando il rivelatore viene inserito nella tazza trasparente dove interrompe il fascio a infrarossi Controlli il tasto Ricevitori all infrarosso Versione 2 Testifire fan ur md 5 12 Autotest RFID Testifire 100 Un modulo di comunicazioni Testifire comprensivo di identificazione a radio frequenza e Bluetooth sara disponibile in futuro come opzione Oltre ad altre funzioni di reporting un rivelatore puo essere identificato tramite un tag RFID fissato nella parte posteriore del rilevatore antincendio Cid consente la comunicazione tra il dispositivo Testifire e il tag e di conseguenza consente al Testifire di identificare il rivelatore ed eseguire automaticamente il i test corretto i senza programmazione Grazie all impiego di un collegamento Bluetooth con protocollo aperto il dispositivo Testifire offre inoltre la possibilita di comunicare con qualsiasi applicazione software abilitata di terzi Cid consente lo scambio di dati tra il tag RFID etichetta e un PDA quali ad esempio le identit del personale che svolge il test la societ addetta alla manutenzione la data e l ora di esecuzione del test e i suoi risultati Per poter utilizzare questa funzione necessario che ciascun rivelatore sia dotato di un tag RFID compatibile con il dispositivo Testifire e che
68. olto calda AVVERTENZA Questo prodotto produce piccole quantit di monossido di carbonio CO un gas pericoloso e inodore NON INALARE direttamente l aria che fuoriesce dal condotto durante un test CO n entro i 5 minuti successivi tale controllo Nota in normali condizioni di utilizzo la quantit di CO prodotta non dannosa per l utente Per ulteriori informazioni fare riferimento alle informazioni sulla sicurezza fornite a parte amp testi fi r e www testifire com Pagina No I Istruzioni generali Garanzia 4 2 Riconoscimento 4 1 3 Riciclo 4 2 Introduzione 5 3 Identificazione dei componenti 6 4 Preparazione per l uso 7 4 Carica delle batterie bastone 7 4 2 Installazione delle batterie a bastone 8 4 3 Rimozione e sostituzione delle capsule fumo e CO monossido di carbonio 9 4 4 Accensione dell unit 10 4 5 Uso dei menu 4 6 Regolazione dell angolazione della testa 4 Verifica dei rivelatori ad alto profilo 2 5 Uso del dispositivo Testifire 13 5 Opzione dispositivo acustico 14 5 2 Verifica di un rivelatore 14 5 3 Verifica del fumo 5 5 4 Verifica del calore 15 5 5 Verifica del monossido di carbonio CO 7 5 6 Aspirazione del rivelatore 7 5 7 Livello di combustibile nelle capsule 18 5 8 Verifica simultanea 19 5 9 Verifica sequenziale 19 5 10 Verifica simultanea sequenziale combinate 20 5 11 Telecomando a infrarossi 21 5 12 Autotest RFID 21 5 13 Tabella di consultazi
69. one dei LED indicativi 22 6 Risoluzione guasti 23 6 I Errori 23 6 2 Reset del sistema 23 6 3 Messaggi di errore e tabella di consultazione dei LED indicativi 24 7 Assistenza 25 7 1 Assistenza tecnica 25 7 2 Aggiornamenti del firmware 25 7 3 Informazioni sul sistema 25 7 4 Manutenzione 25 7 5 Assistenza 26 7 6 Promemoria di servizio 27 7 6 Struzioni per il software Testifire Flash Loader 28 8 Specifiche tecniche 34 8 I Ricambi disponibili per la sostituzione sul campo 35 9 Sistema di selezione prodotti 36 10 Accordo di licenza con l utente finale 37 Opzione futura amp testi fi r e www testifire com vi I Istruzioni generali 1 1 Garanzia Oltre a qualsiasi altra garanzia espressa fornita per iscritto dalla Societ in relazione alla merce la Societ garantisce che la merce fornita ai sensi di questi termini e condizioni conforme alle specifiche se presenti riportate sull Ordine di acquisto e che non presenta difetti di materiale e di fabbricazione per un periodo di 18 mesi a partire dalla data di consegna all acquirente o per un periodo di 12 mesi a partire dalla data di vendita da parte dell acquirente al cliente finale a seconda di quale periodo il pi breve 1 2 Riconoscimento Testifire Solo e Battery Baton sono marchi registrati di No Climb Products Ltd Qualsiasi altro nome di marchio riportato un marchio o un marchio registrato del rispettivo proprietario e viene qui riconosciuto 2010 No Cl
70. orma la parte superiore della tazza trasparente interna deve essere parallela alla base del rivelatore Il soffietto dovrebbe teoricamente aderire alla superficie superiore Quando si controllano rivelatori ad alto profilo potrebbe essere necessario rimuovere la tazza trasparente interna per consentire il corretto posizionamento del rivelatore ai fini di un buon esito del test La tazza trasparente interna presenta una fessura semicircolare sul lato pi vicino all interfaccia utente Inserire un dito nella fessura e sollevare delicatamente la tazza trasparente interna Fig 27 CONSIGLIO II LED del rivelatore dovrebbe essere visibile attraverso la tazza interna della testa In alcuni casi ci non possibile Per migliorare la visibilit del LED del rivelatore abbassare brevemente il Testifire max 2 secondi quindi risollevarlo per proseguire il test In caso di test ad un unico stimolo il colore del LED Tipo di test unico mentre nel caso di una sequenza di test ad un unico stimolo il LED assume il colore relativo al test in corso In caso di test multistimolo simultanei il LED assume il colore relativo agli stimoli coinvolti nel test alternando ripetutamente i colori Se dopo 2 minuti il test non terminato il Testifire si disattiva Una volta attivato il rivelatore rimuovere il dispositivo Testifire abbassandolo delicatamente Il dispositivo Testifire torna in modalit STANDBY mentre viene ripristinato il raggio a
71. ottimali Un equilibrio e un appoggio in sicurezza garantiscono un migliore controllo del dispositivo in situazioni impreviste Prestare particolare attenzione a non toccare oggetti sopraelevati quali plafoniere cavi di alimentazione barre di distribuzione sopraelevate e qualsiasi altro oggetto che possa staccarsi accidentalmente e mettere in pericolo l operatore o chiunque si trovi nelle vicinanze ATTENZIONE Questo prodotto presenta superfici calde e dai condotti fuoriesce aria calda NON TOCCARE la punta della capsula CO una volta rimossa qualora l unit sia stata in funzione negli ultimi 5 minuti Dopo l uso l unit estremamente calda e se toccata pu causare ustioni NON inserire le dita nella fessura da cui stata rimossa la capsula CO Le superfici sono estremamente calde e se toccate possono provocare ustioni Non avvicinare le mani all uscita dei condotti durante la verifica del calore n nei 5 minuti successivi tale verifica Dal condotto fuoriesce aria calda e la parte superiore del condotto pu essere molto calda AVVERTENZA Questo prodotto produce piccole quantit di monossido di carbonio CO un gas pericoloso e inodore NON INALARE direttamente l aria che fuoriesce dal condotto durante un test CO n entro i 5 minuti successivi tale controllo Nota in normali condizioni di utilizzo la quantit di CO prodotta non dannosa per l utente Per ulteriori informazioni fare riferimento alle infor
72. r scorrere il menu e il tasto INVIO per selezionare la voce Lingua Fig 14 Premendo il soma tasto ESC si torna alla schermata STANDBY gt Lingua Preparazione Sirena in corso Reset Sistema Attendne Dopo lunghi periodi di inutilizzo o in caso di sostituzione di una capsula fumo al momento dell accensione l unit si avvia automaticamente prima di visualizzare il menu PRINCIPALE Sul dispositivo compare per un breve intervallo di tempo il messaggio Preparazione in corso Attendne ad indicare che l unit sta attivando i circuiti pronti per l uso Fig 15 Se l unit resta in modalit Standby per pi di 5 minuti si spegne automaticamente per conservare la batteria AN gt Te S ti fi re www testifire com 10 ar 4 5 Uso dei menu Prima di accendere il dispositivo Testifire per la prima volta importante aver acquisito dimestichezza con i menu del sistema menu del dispositivo Testifire sono facili da utilizzare Utilizzando i tasti di navigazione SU e GIU amp possibile spostare il cursore attraverso il menu PRINCIPALE Fig 16 Premere il tasto INVIO per selezionare gli stimoli nel menu PRINCIPALE o per visualizzare i sottomenu Tasto Menu Tasto Stato Premendo il tasto ESC si torna al menu PRINCIPALE oppure quando stata programmata una sequenza di test ed visualizzato il menu PRINCIPALE il tasto ESC
73. rcostante il sensore termico del rivelatore al fine di preservare la carica della batteria AN Te S ti fi re www testifire com 15 ar Per i rivelatori a temperatura fissa che funzionano a oltre 90 C 194 F disponibile l impostazione Calore Per la maggior parte dei test si raccomanda di utilizzare l impostazione Calore calore normale che consente di preservare la carica della batteria Per selezionare un test con Caloret utilizzare i tasti SU e GIU amp del tastierino per evidenziare la voce pone hr alore Calore Premere il tasto STATO del tastierino Fig 32 Timer On quindi portare il cursore su Calore Fig 33 utilizzando i tasti SU e GIU del tastierino Premere il tasto INVIO per selezionare Calore Dopo aver selezionato la voce Calore il dispositivo Testifire torna tuttavia all impostazione Calore in seguito allo spegnimento e al successivo riavvio del dispositivo Note speciali per i rivelatori di calore rivelatori di calore dispongono di un sensore termico in genere un termistore che rileva il calore Questo sensore generalmente montato in posizione centrale all interno del rivelatore e consente un agevole allineamento del dispositivo Testifire In caso dei rivelatori di calore a doppio termistore o con termistori di offset il condotto principale della testa del dispositivo Testifire deve esser
74. re Protezione della batteria da sovracorrente Max 2 minuti di timeout nel corso del test Spegnimento automatico dopo 5 minuti di non utilizzo Produzione di CO su richiesta nessuna riserva di gas LED di feedback utente codificato per colore Rilevamento automatico a infrarossi del rivelatore Testa multiposizione regolabile Configurazione opzionale perfettamente automatica Modalit automatica RFID Rivelatori di fumo ottici fotoelettrici e a ionizzazione Sensori termici a temperatura fissa o termovelocimetrici Sensori di monossido di carbonio CO Rivelatori multisensore o multicriterio Rivelatori tradizionali indirizzabili o indirizzabili analogici di qualsiasi dei suddetti tipi Range della temperatura di esercizio da 5 C a 45 C da 41 F a 113 F Range dell umidit di esercizio UR dallo 0 all 85 senza formazione di condensa Range della temperatura di stoccaggio da 10 C a 50 C da 50 F a 122 F Range dell umidit di stoccaggio UR dallo 0 al 90 senza formazione di condensa fino a 35 C 95 F Conforme IEC60529 fino a IP20 amp testi fi r e www testifire com 34 Pesi Testifire 1000 990 g compreso il bastoncino batteria Testifire 2000 1 23 kg compreso il bastoncino batteria Batteria a bastone Solo 760 0 5 kg Dimensioni Testifire 1000 Larghezza del soffietto max 153mm Altezza della testa max 224mm 397 mm compresa l impugnatura Testifire 2000 Larghezza del so
75. sula usata ed estrarla delicatamente verso l esterno Istruzioni per la sostituzione delle capsule fumo Rimuovere la capsula dal cartone esterno e dalla custodia antistatica i Protezione Rimuovere il cappuccio di protezione delle clip a molla Fig 8 della nuova delle dips capsula molla Afferrando la capsula per le clip a molla B Fig 8 con l etichetta rivolta verso il basso inserire con cautela la nuova capsula nella rispettiva porta Spingerla in posizione accertandosi che le clip fuoriescano su entrambi i lati della capsula e si incastrino correttamente con la porta Clip a molla Chiudere bene la copertura fumo A Fig 7 an np testi fi r e www testifire com Istruzioni per la rimozione delle capsule CO solo Testifire serie 2000 Sostituire la capsula CO solo quando vuota Lasciare spento il dispositivo Testifire per cinque minuti in modo che la capsula si raffreddi prima di essere rimossa Aprire la copertura inferiore D Fig 9 del dispositivo Testifire dal lato destro Premere le clip a molla E Fig 9 su ciascun lato ed estrarre delicatamente la capsula verso l esterno Non toccare la punta della capsula CO poich potrebbe essere calda Istruzioni per la sostituzione delle capsule CO Protezione della punta Pia Rimuovere la capsula dal cartone esterno e dalla custodia antistatica P P I Rimuovere la protezione della punta della capsula F Fig 1
76. t may not be excluded or limited as a matter of law 5 2 Subject to condition 5 1 the Licensor shall not be liable under or in connection with this Agreement or any collateral contract for a loss of income SRH SM SM 573 4 502256 8 b loss of business profits or contracts c business interruption d loss of the use of money or anticipated savings e loss of information f loss of opportunity goodwill or reputation g loss of damage to or corruption of data or h any indirect or consequential loss or damage of any kind howsoever arising and whether caused by tort including negligence breach of contract or otherwise provided that this condition 5 2 shall not prevent claims for loss of or damage to your tangible property that fall within the terms of condition 4 or any other claims for direct financial loss that are not excluded by any of categories a to h inclusive of this condition 5 2 5 3 Subject to condition 5 1 and condition 5 2 the Licensor s maximum aggregate liability under or in connection with this Agreement or any collateral contract whether in contract tort including negligence or otherwise shall be limited to a sum equal to 100 of the price of the related Licensor s Products and Software giving rise to liability 5 4 Subject to condition 5 1 condition 5 2 and condition 5 3 the Licensor s liability for infringement of third party intellectual property rights shall be limited to breaches of rights su
77. uter avvier il programma di installazione Found New Hardware Fare riferimento alle istruzioni presenti nella Guida all Installazione del Driver Testifire link qui prima di installare i driver Per procedere i driver devono essere installati correttamente Testifire Flash Loader Connect the USB cable to Testifire and then to the computer The first time Testifire is connected the Found New Hardware Wizard will launch Please complete this process before proceeding Instructions provided in the Testifire Driver Installation Guide M SA or click on Help To continue click Next Passo 4 L applicazione avviera la scansione delle porte USB del computer per rilevare i dispositivi collegati Questo processo dovrebbe essere immediato e sar seguito dalla visualizzazione dello schermo qui sotto Testifire Flash Loader Connected Firmware Version 5 2 Model 2000 Serial Number 2108384 To continue click Next Se Testifire non viene rilevato immediatamente il processo di scansione continuer fino alla sua effettiva rilevazione oppure si interromper se l utente seleziona i comandi Back o Cancel Testifire Flash Loader Scanning USB Ports Il mancato rilevamento di Testifire potrebbe essere dovuto ad una delle seguenti ragioni L unit non accesa Il cavo USB non collegato correttamente driver USB per il dispositivo Testifire non sono installati correttamente
78. vizio di promemoria stata aggiunta a partire dalla versione 5 4 del firmware uscita a novembre 2009 Servizio Ricordo Spenga y testi fi r e www testifire com 27 7 7 Istruzioni per il software Testifire Flash Loader Per i modelli Testifire 1000 e 2000 A Benvenuto al software Testifire Flash Loader Installare il software Flash Loader prima di collegare Testifire al computer Introduzione Testifire Flash Loader un applicazione gratuita per sistemi operativi Windows che permette di aggiornare il firmware di Testifire direttamente su Testifire e senza la necessit di restituire il prodotto Flash Loader permette all utente di aggiornare Testifire con l ultima versione di firmware via computer collegandolo ad una porta USB Prima di utilizzare Testifire Flash Loader per aggiornare il firmware dell unit Testifire necessario installare l applicazione e i driver USB di Testifire vedere le istruzioni d installazione qui sotto Per utilizzare Testifire Flash Loader necessario un PC collegato ad internet Per gli utenti avanzati il sistema pu anche essere utilizzato senza una connessione ad internet se in precedenza si scaricato l apposito file binario Firmware Vedere www testifire com SI PREGA DI LEGGERE LE SEGUENTI ISTRUZIONI PRIMA DI PROCEDERE ALL INSTALLAZIONE Cosa il Firmware Il Firmware un programma per computer integrato in un dispositivo hardware in questo caso Testi