1. Channel Function in ARC FULL mode nn Channel Function in ARC1 mode un RED 1 MASTER DIMMER 000 255 1 janes forage 2 RED 000 255 2 GREEN 0 100 000 255 3 GREEN 000 255 BLUE 3 0 100 000 255 4 BLUE 000 255 COLOR MACRO Channel Function in ARC1 D mode value No function 000 010 1 MASTER DIMMER R 100 G Up B 0 011 030 0 100 000 255 R Down G 100 B 0 031 050 An R 0 G 100 B Up 051 070 2 b R 0 G Down B 10006 071 090 97100 75 R Up G 0 B 100 091 110 GREEN R 100 G 0 B Down 111 130 3 0 100 000 255 R 100 G Up B Up 131 150 R Down G Down B 100 151 170 4 BLUE R 100 G 100 B 100 0 100 000 255 W 100 171 200 White 1 3200 K 201 205 FE DMX White 2 3400 K 206 210 Channel Function in SPECIAL 1 mode value White 3 4200 K 211 215 White 4 4900 K 216 220 1 MODULE 1 RED White 5 5600 K 221 225 0 100 000 255 White 6 5900 K 226 230 MODULE 1 GREEN White 7 6500 K 231 235 2 0 100 000 255 White 8 7200 K 236 240 White 9 8000 K 241 245 a MODULE 1 BLUE White 10 8500 K 246 250 0 100 000 255 White 11 10000 K 251 255 MODULE 2 RED STROBE 3 0 100 000 255 No function 000 009 E MODULE 2 GREEN 1 20 Hz 010 255 0 100 000 255 DIMMER SPEED MODULE 2 BLUE 0 100 000 255 Return to DIMMER 000 009 7 OFF 010 29 DMX Speed 1 fastest 030 069 Channel Function in SOLID mode T Speed 2 070 129 Speed 3 130 189 1 RGB MASTER DIMMER 000 255 Speed 4 slovvest 1
2. La connesione DMX realizzata utilizzando cavi schermati 2 poli massa ritorti con impendenza 1200 e bassa capacit Per il collegamento fare riferimento allo schema di connessione riportato a pag 9 Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In tal caso sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poich non in grado di trasmettere in modo affidabile i dati di controllo DMX Fig 10 e Collegare l uscita DMX del controller con l ingresso DMX della prima unit e Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di quella successiva e via dicendo finch tutte le unit sono collegate formando una catena e Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze consigliato inserire sull ultima unit una terminazione DMX La terminazione evita la probabilit che il segnale DMX 512 una volta raggiunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della catena saldando una resistenza di 1200 minimo 1 4W tra i Pin 2 e 3 14 ARCGROUND36RGB 3 7 Tabella canali DMX
3. rchWork ARCHITECTURAL CONCEPT ARCGROUND36RGB ARCHITECTURAL LIGHTING Manuale Utente User Manual 101 10A WOL DOI O REV 001 07 11 ARCGROUND36RGB INDICE Sicurezza Avvertenze generali i Attenzioni e precauzioni per l installazione cite 0 Informazioni general 1 Descrizione e specifiche tecniche 1 1 Elementi di comando e collegamenti 5 1 2 Descrizione s 6 1 3 Specifiche tecniche 6 2 Installazione 2 1 Montaggio 2 7 2 2 Schema di connessione 2 3 Regolazione del fascio luminoso 227v v7v77 2 4 Connessione all alimentazione 9 2 5 Connessione al segnale di controllo 9 3 Funzioni e impostazioni 3 1 Funzionamento tramite controller ARCMAT 10 3 2 Impostazione base 11 3 3 Struttura del MENU 12 3 4 Configurazioni canali DMX 212 3 5 Modalita DMX serum S 3 6 mpostazione dell indirizzo start sini 13 3 7 Tabella canali DMX ee NA 3 8 Istruzioni per la configurazione ARCFULL 0277777 3 9 Funzioni speciali sasa sm US 3 10 Dimmer s rm 3 11 Calibrazione bianco iaia WO 4 Manutenzione 4 1 Pulizia sistema ottico e manutenzione 16 Certificato di garanzia CONTENUTO DELL IMBALLO ARCGROUND36RGB Man
4. 255 No function 000 009 E MODULE 2 GREEN 1 20 Hz 010 255 0 100 000 255 DIMMER SPEED P MODULE 2 BLUE 0 100 000 255 Return to DIMMER 000 009 7 OFF 010 29 DMX Speed 1 fastest 030 069 Channel Function in SOLID mode T Speed 2 070 129 Speed 3 130 189 1 RGB MASTER DIMMER 000 255 Speed 4 slovvest 190 255 NOTE R Red G Green B Blue W White ARCGROUND36RGB 13 3 8 Basic instructions for DMX operation ARCFULL MASTER DIMMER CH1 controls the intensity of the currently projected color When the slider is at the highest position 255 the intensity of the output is the maximum RED GREEN AND BLUE COLOR SELECTION CH2 CH3 and CH4 control the intensity ratio of each of the red green blue When the slider is at the highest position 255 the intensity of the color is the maximum CH2 CH3 and CH4 can be combined together to create over 16 million colors COLOR MACROS AND WHITE BALANCE CH5 selects the required COLOR MACRO and whites in different color temp CH5 has priority over CH2 CH3 and CHA CH1 is used to control the intensity of the COLOR MACRO STROBE CH6 controls the strobe of CH1 to CH5 DIMMER SPEED CH7 is used to select the kind of dimmers curve required 3 9 Special functions Press the button MENU and select through the directional buttons the SETTINGS mode and press the button ENTER to confirm It is possible to view to following functions COLOR COLOR is for activate deactivate the
5. Wiring diagrams 20 2 3 Adiust the beam angle 3060 0 2 4 Power connections 7 2 5 Signal connections 7 3 Functions and settings 3 1 Operation via ARCMAT controller 8 DD BASIC za s 9 3 3 Menu structure Be essen MO 3 4 DMX configurations 10 3 5 DMX Mode i 3 6 DMX addressing 3 11777 7 3 7 DMX control on 12 3 8 Basic instructions for DMX operation ARCFULL s s 13 3 9 Special funetions u LS A A IS 3 11 White calibration 15 4 Maintenance 4 1 Cleaning the unit and maintenance 14 Warranty PACKING CONTENT ARCGROUND36RGB e User manual All rights reserved by Music amp Lights S r l No part of this instruction manual may be Reproduced in any form or by any means for any commercial use Design and specifications are subject to change without notice 2 ARCGROUND36RGB WARNING Before carrying out any operations with the unit carefully read this instruction manual and keep it with cure for future reference It contains important information about the installation usage and maintenance of the unit SAFETY General instructions The products referred to in this manual conform to the European Community Directives and are therefore marked with ce The unit is supplied with hazardous network voltage 230V Leave servicing to skilled personnel only Never make
6. any modifications on the unit not described in this instruction manual otherwise you will risk an electric shock Connection must be made to a power supply system fitted with efficient earthing Class appliance according to standard EN 60598 1 It is moreover recommended to protect the supply lines of the units from indirect contact and or shorting to earth by using appropriately sized residual current devices The connection to the main network of electric distribution must be carried out by a qualified electrical installer Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label This unit is not for home use only professional applications Never use the fixture under the following conditions in places subject to vibrations or bumps in places with a temperature of over 40 C or less than 20 C Make certain that no inflammable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly Ifthe unit is to be put out of operation definitively take it to a local recycling E plant for a disposal which is not harmful to the environment Warnings and installation precautions Never look directly at the light beam Every person involved with installation and
7. color calibration functions When RGB is selected on RGB 255 255 255 the color is displayed as calibrated in CAL2 RGB When COLOR is set OFF on RGB 255 255 255 the RGB values are not adjusted and the output is most powerful When UC is selected the RGB output adjusted to a standard preset universal color which balances fixtures from different generations RESET In order to reset custom modesto default values select RESET 3 10 Dimmer Enter Dim to select dimmer mode and dimmer speed When dimmer is set to OFF the RGB and MASTER DIMMER are linear The Dim1 2 3 4 are speed modes of the non linear dimmer Dim1 is the faster while Dim4 is the slowest Note The factory default setting is Dim4 14 ARCGROUND36RGB 3 11 White calibration Enter the CALIB mode to select white color of different color temperature Press the button MENU so many times until show CAL1 and press the button ENTER to confirm There are 11 pre programmed white colors WHITE01 WHITE11 can be edited by using red green and blue Red Green Blue through the UP and DOWN Note In the ARCFULL configuration is possible to balance custom color temperature settings by selecting white WHITEO1 WHITE11 CH5 Select RGB to set the values 000 255 on the CH red green and blue 4 MAINTENANCE 4 1 Cleaning the unit and maintenance Make sure the area below the installation place is free from unwanted persons during se
8. juawidinba y JI 3AID3Ya aq s 5uo ou im agzuesenb ayy Juawd nba 1931103u1 pue Aq pasne 512 aajuesenb INO uo a gejiene woy ay Bulpuas pue ul Bury pasaysibau Osje aq ued PNPold ay SIYBIDISNUIMMM uo y aseydund no Jaye uoos Juswd nba adaid y 1951634 o 19QUIAUIIA asea q SUOI IPUOD Bd URIEND euD 122215 Ws UYBIPISNU MMM ays Q M Ano UO SUOI IPUOD aazURJeNDH je13U39 Y JO UOISISA NJ dy puy uv no suonejnbaa Bunsixe u a gt uer duro ul yun v 5 aazuesenb ay DIZUDID IP 0103419 19 Jap auolzbjuasaid pilbp a DIZUDID maya mmy 310ssassod jap 031103 b ouos n nb suoo Iyasu OJIOASDA ip s ds WIgoyodsp H yinil yul 116 appdwpj ausajsa Iod aj DIZUDID asnj gt sa 0142234Dddb jjap uolzn nsos bj apana d DIZUDIDD DT OSSA UOUDWI 015 DIS 01Y2934Dddb onaya by uou DIZUDID DT 0142234Dddb jjap uou osn pp p zuodw nosno nspn6 5 25 04334 NS 1 JI opubinui 0301351631 a assa ond DAI DUI3I D l
9. maintenance of this device have to be qualified and follow the instruc tions of this manual Before starting any maintenance work or cleaning the projector cut off power from the main supply Keep any inflammable material at a safe distance from the fixture Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their ef fectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed When cleaning loudspeakers please do not use solvents such as acetone or alcohol since they may damage the of the unit outer finish GENERAL INFORMATION Shipments and claims The goods are sold ex works and always travel at the risk and danger of the distributor Eventual damage will have to be claimed to the freight forwarder Any claim for broken packs will have to be forwarded within 8 days from the reception of the goods Warranty and returns The guarantee covers the fixture in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the validity of the guarantee is endorsed solely on presentation of the guarantee certificate Musi
10. tel 39 0771 72190 fax 39 0771 721955 Certified Company www musiclights it info musiclights it ARCHWORK is a brand of Music amp Lights S r l company 2011 Music amp Lights S r l LU OL D01 101 10 101 101 105 101 101 101 101 101 ARCHWORK un brand di propriet della Music amp Lights S r l
11. 1 Mounting Embed the outer casing first before installing the fixture Fig 2 254 Correct Wrong Wrong Nota The stainless steel cover should not exceed the ground 3000 kg dd The fittings has been designed and tested to withstand a static load of 3000 kg based on the outer casing Fig 3 DRAINPIPE Immersion will encourage condensation inside the fixture a valve in the fixture equalizes pressure as the fixture heats up and cools down The valve allows air into the fixture but prevents the entry of water 6 ARCGROUND36RGB 2 2 Wiring diagrams Unscrew the junction box and remove the cover Fetch the terminal for cable connection Put the cable 6 8 mm through the junction box e Tighten the terminal with the cable according to the instruction Screw the junction box 6 8 mm Terminal DATA GND Black LIVE Black DATA Green EARTH Green DATA Red NEUTRAL White Fig 4 2 3 Adjust the beam angle The bolts that secure frame to the body must be fully tightened in a uniform manner alternating between diametrically opposed bolts To facilitate the extraction of the glass without damaging the seal unscrew all the nuts except for two adjacent ones and wait a few seconds then unscrew the remaining nuts and remove the glass ARCGROUND36RGB 7 2 4 Power connections L Brown N Blu E Green Yellow L Brown N Blu E Green Y
12. 90 255 NOTE R Red G Green B Blue W White ARCGROUND36RGB 15 3 8 Istruzioni di base per il funzionamento DMX nella configurazione ARCFULL MASTER DIMMER Il canale 1 controlla l intensit di luce del proiettore Quando il cursore del controller posizionato al valore massimo 255 l intensit d uscita massima RED GREEN E BLUE COLOR SELECTION canali 2 3 e 4 controllano d intensit dei Led relativi al colore rosso verde blu Quando il cursore posizionato al valore massimo 255 l intensit del colore massima valori DMX regolati dai canali 2 3 e 4 possono essere combinati insieme per creare 16 milioni di colori COLORE MACRO E BILANCIAMENTO BIANCO e I canale 5 seleziona la macro colore e bianchi a temperatura colore diversa Il canale 5 ha la priorit sui canali 2 3 e 4 e I canale 1 usato per controllare l intensit di colore delle macro STROBE Il canale 6 controlla la strobo dei canali da 1 a 5 DIMMER SPEED I canale 7 usato per selezionare il tipo di curva dimmer richiesto 3 9 Funzioni speciali Premere il tasto MENU e selezionare attraverso i tasti direzionali la voce SETTINGS per confermare pre mere il tasto ENTER possibile accedere alle seguenti funzioni COLOR Selezionando la funzione COLOR possibile attivare disattivare le modalit calibratura colore Quando RGB selezionato su RGB 255 255 255 il colore visualizzato
13. IONE E SPECIFICHE TECNICHE 1 1 Elementi di comando e di collegamenti 9 ADAN Fig 1 COVER in acciaio inox VETRO temperato 15mm DIAFRAMMA PIASTRA LED LED PCB DISSIPATORE DI CALORE INTERRUTTORE DI ALIMENTAZIONE SCHEDA DI CONTROLLO INVOLUCRO INTERNO 10 INVOLUCRO ESTERNO 11 BORDO 6 ARCGROUND36RGB 1 2 Descrizione ARCGROUND36RGB un illuminatore ultracompatto 36W RGB realizzato appositamente per applicazioni outdoor incassate Il sistema di sintesi colore elettronico RGB garantisce una potente emissione luminosa con range cromatico senza limiti Il grado di isolamento interno IP67 e la capacit di carico superiore a 3000Kg rendono ARCGROUND36RGB adatto in qualsiasi ambiente di utilizzo anche in zone addette al traf fico veicolare Il sistema di controllo digitale basato su protocollo DMX512 includendo anche sequenze di colori pre memorizzate per un immediato funzionamento sincronizzato di pi unit collegate in catena L unit di alimentazione gi implementata all interno evitando apparecchiature aggiuntive esterne 1 3 Specifiche tecniche Sorgente luminosa e ottica 36x 1WCREELED RGB 12 rosso 12 verde 12 blu Angolo di proiezione 30 Lumen 900 Im Lux 2m 800 lux Sistema di sintesi colore miscelazione RGB gt 16 milioni di colori per possibilit cromatiche illimitate Durata media diodi LED gt 50 000 ore Funzionamento ed elettronica Mo
14. MENU DIMMER RED 000 255 GREN 000 255 BLUE 000 255 STRB 000 20 OFF COLOR EN RGB TO W UC STATIC SETTINGS gt do cto cia oe NO YES RESET 3 4 DMX configurations ARCGROUNG36RGB is equipped with 5 DMX configuration Press the button MENU so many times until shows PERSON and press the button ENTER to confirm Select the desired DMX configuration ARC 1 ARC 1 D ARC FULL SOLID SPECIAL 1 through the buttons UP and DOWN Note REMOTE setting is a function not enabled The tables on page 12 indicate the operating mode and DMX value As DMX interface the unit has a 3 wire signal cable ARCGROUND36RGB 11 3 5 DMX Mode Press the button MENU so many times until the display shows DMX Press the button ENTER to confirm Press the buttons UP and DOWN to select the desired value 001 512 hold to scroll quickly After setting the value is saved automatically 3 6 Setting the start To able to operate the ARCGROUND36RGB with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust the start address 33 on the ARCGROUND36RGB The other functions of the light effect panel are then automatically assigned to the f
15. YSIY IDISNUIMMM 15 ns Jap 2UOIZDAISIDAA 1 p 201d Ip o3simb gt b odop Dbald IS DIZUDADD Ip D1aUaD JUOIZIPUO 01101953 DIZUDADO Ip 0 JUOIZIPUO ll p 0353 2340J NSUO ajiqissod ar s yb p snummMm 15 ins Anpuuou nuabia lib aspq ul pIZUDAD opopoid MODEL MODELLO MODEL MODELLO NL SERIAL N SERIE N SERIAL N SERIE N Purchased by Acquistato da Purchased by Acquistato da SURNAME COGNOME SURNAME COGNOME id NAME NAME NOME ADDRESS VIA N ADDRESS VIA N LY CITY CITTA CITY CITTA ZIP CODE C A P PROV ZIP CODE C A P PROV 6 D CT 4 Dealer s stamp Dealer s stamp and signature and signature Timbro e firma Timbro e firma del Rivenditore del Rivenditore Purchasing date Purchasing date Data acquisto Data acquisto FORMTO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE Music amp Lights S r l ____ entertainment technologies Via Appia km 136 200 04020 Itri LT ITALY ISO 9001 2008
16. a e tensione della rete corrispondono alla frequenza ed alla tensione per cui l unit predisposta indicate sulla targhetta dei dati elettrici L unit non per uso domestico solo per uso professionale Evitare di utilizzare l unit in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiore ai 40 C o inferiori a 20 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecnica autorizzato Sesi desidera eliminare il dispositivo definitivamente consegnarlo per lo smaltimento ad un istituzione locale per il riciclaggio E Attenzioni e precauzioni per Finstallazione Non guardare direttamente il fascio luminoso Ogni persona coinvolta con l installazione e la manutenzione di questo prodotto deve essere qualificata e seguire le istruzioni di questo manuale Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull unit togliere la tensione dalla rete di alimenta zione Mantenere materiali infiammabili ad una distanza di sicurezza dall unit Ifiltri le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro efficienza LED devono essere sostituiti se danneggiati o termicamente deformati Perla pulizia del prodotto non usare s
17. amento e i relativi valori DMX Come interfaccia DMX l unit possiede cavo di segnale a 3 fili ARCGROUND36RGB 13 3 5 Modalita DMX Per poter entrare nella modalita DMX Premere il tasto MENU fino a quando sul display non appare DMX Premere il tasto ENTER per confermare la scelta Premere i tasti UP o DOWN per selezionare il valore desiderato 1001 512 tenere premuto per lo scorri mento veloce Al termine dell impostazione il valore verr salvato automaticamente 3 6 Impostazione dell indirizzo di start Per poter comandare ARCGROUND36RGB con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per co mandare la funzione del primo canale DMX si deve impostare sull ARCGROUND36RGB l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Segue un esempio con indirizzo 33 di start e una configurazione a 4 e a 7 canali DMX Numero Indirizzo di Indirizzo DMX Prossimo indirizzo di start Prossimo indirizzo di start Prossimo indirizzo di start canali DMX start esempio occupati possibile per unit n 1 possibile per unit n 2 possibile per unit n 3 4 33 33 36 37 41 45 7 33 33 39 40 47 54 Esempio di configurazione a 7 canali DMX modalit ARCFULL DMX Address 33 DMX Address 40 DMX Address 47 DMX Address 54
18. c amp Lights will verify the validity of the claim through examination of the defect in rela tion to proper use and the actual validity of the guarantee Music amp Lights will eventually provide replacement or repair of the products declining however any obligation of compensation for direct or indirect damage resulting from faultiness The information provided in this manual has been carefully checked However Music amp Lights S r l is not responsible for any possible inaccuracy ARCGROUND36RGB 1 DESCRIPTION AND TECHNICAL SPECIFICATIONS 1 1 Operating elements and connections 9 ADAN gt 10 11 Fig 1 STAINLESS STEEL COVER 15mm template GLASS DIAPHRAGM LED PLATE LED PCB HEAT SINK POWER SWITCH CONTROL BOARD INNER HOUSING 10 OUTER CASING 11 DUST PROOF BOARD 4 ARCGROUND36RGB 1 2 Description ARCGROUND36RGB is an ultra compact 36W RGB luminaire expressly designed for recessed inground out door applications RGB electronic synthesis allow a powerful light output featuring a limitless colour range IP67 protection rate and 37000 Kg static load capacity make ARCGROUND36RGB suitable for all kinds of outdoor environments even for roadways Digital control system is based on DMX protocol with built in automatic chromatic sequences for an immediate synchronized operation of more units linked in a chain Power supply is integrated in the housing avoiding additional external pow
19. come calibrato nella modalit CAL2 RGB Quando COLOR impostato su 0FF su RGB 255 255 255 il colore non pu essere regolato e l uscita mostrer la massima potenza Quando UC selezionato i colori sono regolati secondo un preset universale standard RESET Selezionando la funzione RESET possibile ripristinare i valori di default 3 10 Dimmer Selezionando la funzione DIM possibile entrare nella modalit dimmer In particolare quando impo stato su OFF RGB e il MASTER DIMMER sono lineari Dim 1 2 3 4 rappresentano invece diversi valori di velocit nella modalit non lineare DIM 1 il valore pi veloce mentre DIM 4 il pi lento Nota Le impostazioni di fabbrica sono su DIM 4 16 ARCGROUND36RGB 3 11 Calibrazione bianco Per impostare il bilanciamento personalizzato della temperatura colore bianco Premere il tasto MENU fino a quando sul display non appare CALIB quindi premere il tasto ENTER Selezionare una delle 11 impostazioni colore bianco pre programmate WHITEO1 WHITE11 Le impostazioni possono essere modificate intervenendo sui valori 000 255 relativi ai canali rosso ver de blu Red Green Blue attraverso i tasti UP e DOWN Nota Nella configurazione ARCFULL possibile effettuare il bilanciamento personalizzato della temperatu ra colore bianco selezionando le impostazioni WHITEO1 WHITE11 del canale 5 Selezionare RGB per impostare i valori 000 255 rela
20. dalit di funzionamento DMX512 colori statici Funzioni RGB 0 100 dimmer regolazione curva dimmer calibrazione colori Interfaccia di controllo DMX coder esterno ARCMAT opzionale Silenziosit di funzionamento proiettore privo di ventole e struttura disegnata per avere una dissipazio ne a convezione naturale Corpo e alimentazione Struttura esterna alluminio vetro temperato Grado di isolamento IP67 Bilanciamento temperatura e pressione attraverso valvole di sfiato GORE microforate e Capacit di carico statico gt 3000kg Controcassa in metallo per incasso a pavimento e parete inclusa e Condizioni di esercizio 40 C 50 C Alimentazione interna 100 240V 50 60Hz Alimentazione Segnale cavi a 3 5 conduttori Consumo ad emissione massima 43W Peso 8kg Dimensioni 320mm diam 146mm profondit Photometric data 3 0 Center Beam LUX Beam Width 3 6m 73m 10 9m 10 0m 14 6m 13 3m 18 2m 16 7m Illuminance at a Distance 21 9m 20 0m Vert Spread 57 0 H Horiz Spread 57 ARCGROUND36RGB 7 2 INSTALLAZIONE 2 1 Montaggio Montare l involucro esterno dell ARCGROUND36RGB prima di procedere all installazione i Fig 2 Nelle figure riportate di seguito riportato il corretto posi
21. ellow POWER junction box 2 5 Signal connections junction box Fig 6 For greater stability it is recommended to use a DMX signal amplifier if you connect more than 20 units or the signal cable is greater than 60 m in length SIGNAL IN junction box Pins Pin 1 Shield Pin 2 Green Pin 3 Red SIGNAL OUT junction box Fig 7 Functions GND O Data input Data input 8 ARCGROUND36RGB 3 FUNCTIONS AND SETTINGS 3 1 Operation via ARCMAT controller After making the connection ARCGROUND36RGB supply 230V 50Hz connect the unit to the external controller ARCMAT through the signal cable 4 For more information on the operation of the controller ARCMAT consult the instruction manual Power ARCMAT DMX OUTPUT XLR socket Pin1 GND Shield Pin2 Negative Pin3 Positive Pin1 GND Shield Black Pin2 Negative Green Pin3 Positive Red SIGNAL CONNECTOR Fig 8 NOTE Connect the DMX coder to the units in series All connected units will be set with the same information Set corresponding DMX address Personality Calibration and Dimmer of fixture through the DMX coder A maximum of 20 units in series can be set by the DMX Coder at the same time ARCGROUND36RGB 9 3 2 Basic To turn the ARCMAT insert the 2 batteries 1 5V included and press the POWER button To turn off the ARCMAT however do n
22. er units 1 3 Technical specifications Light source and optics 36x 1W CREE RGB LEDs 12red 12 green 12 blue Beam angle 30 Lumen 900 Im Lux 2m 800 lux Colour synthesis RGB colour mixing gt 16 million colours for a limitless colour range LEDs average life span gt 50 000h Electronics and features Function mode DMX512 static colours Features RGB 0 100 dimming curve selection colour calibration User interface through ARCMAT external coder optional Silent operations due to natural cooling of the peculiar chassis and to absence of fans Structure and power supply Housing die cast aluminium tempered glass Internal Protection IP67 Pressure and temperature balance through GORE membrane vents Static load capacity gt 3000kg Aluminium mounting box for wall and in ground applications Working condition 40 C 50 C Power unit internal 100 240V 50 60Hz Power Data cable 3 5 conductors Max output consumption 43W Weight 8kg Dimensions mm 320 diam 146 depth Photometric data 3 0 Center Beam LUX Beam Width 3 3m 7 3m 6 7m 10 9m 10 0m 14 6m 13 3m 18 2m 16 7m Illuminance at a Distance 21 9m 20 0m Vert Spread 57 0 H Horiz Spread 57 ARCGROUND36RGB 5 2 INSTALLATION 2
23. nel menu selezionato o confermare il valore attuale della funzio ne o l opzione all interno di un menu 12 ARCGROUND36RGB 3 3 Struttura del menu ATTENZIONE Per l ARCGROUND36RGB sono abilitate sul controller ARCMAT solo le funzioni riportate di seguito DMX 001 512 ARC 1 ARC 1 D ARC FULL REMOTE SOLID SPECIAL 1 PERSON WHITEO1 WHITEO2 RED 000 255 GRENI000 255 BLUE 000 255 CALIB WHITE 11 RED 000 255 RGB TO W El GRENI000 255 BLUE 000 255 OFF DIM 1 DIM 2 DIM 3 DIM 4 MENU DIMMER RED 000 255 GREN 000 255 BLUE 000 255 STRB 000 20 OFF COLOR RGB TO W UC NO RESET YES STATIC SETTINGS nom rm mmm 3 4 Configurazioni canali DMX ARCGROUND36RGB dispone di 5 configurazioni dei canali DMX a cui si pu accedere dal pannello di controllo Premere il tasto MENU fino a quando sul display non appare PERSON quindi premere il tasto ENTER Attraverso i tasti UP e DOWN selezionare la configurazione dei canali DMX che si desidera ARC1 ARC1 D ARC FULL SOLID SPECIAL 1 Nota l impostazione REMOTE una funzione non abilitata Le tabelle a pagina 14 indicano le modalit di funzion
24. ollowing addresses An example with a start address 33 and con figuration to 4 and 7 DMX channels Numberof Start address DMX Address Next possible start Next possible start Next possible start DMX channels example occupied address for unit No 1 address for unit No 2 address for unit No 3 4 33 33 36 37 41 45 7 33 33 39 40 47 54 Example 7 DMX channels configuration mode ARCFULL DMX Address 33 DMX Address 40 DMX Address 47 DMX Address 54 DMX connection employs shielded pair twisted cables 2 poles earth with 1200 impedance and low capacity For connection refer to the connection diagram shown on page 7 Over long runs can be necessary to insert a DMX level matching amplifier For those connections the use of balanced microphone cable is not recommended because it cannot transmit control DMX data reliably Fig 10 Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit The termination avoids the risk of DMX 512 signals being reflected back along the cable when they reaches the end of the line under certain conditions and with certain cable lengths this could cause them to cancel
25. olventi tipo acetone o alcool per non danneggiare la finitura esterna INFORMAZIONI GENERALI Spedizioni e reclami Le merci sono vendute franco nostra sede e viaggiano sempre a rischio e pericolo del distributore cliente Eventuali avarie e danni dovranno essere contestati al vettore Ogni reclamo per imballi manomessi dovr essere inoltrato entro 8 giorni dal ricevimento della merce Garanzie e resi Il prodotto coperto da garanzia in base alle vigenti normative Sul sito www musiclights it possibile consultare il testo integrale delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia Music amp Lights constata tramite verifica sui resi la difettosit dichiarata correlata all appropriato utilizzo e l effettiva validit della garanzia provvede quindi alla riparazione dei prodotti declinando tuttavia ogni obbligo di risar cimento per danni diretti o indiretti eventualmente derivanti dalla difettosit Le informazioni riportate in questo manuale sono state attentamente controllate Music amp Lights S r l non si assume tuttavia responsabilit derivanti da eventuali inesattezze ARCGROUND36RGB 1 DESCRIZ
26. one dei due adiacenti e attendere qualche secondo quindi svitare i dadi rimanenti e rimuovere il vetro ARCGROUND36RGB 9 2 4 Connessione all alimentazione L Brown N Blu E Green Yellow L Brown N Blu E Green Yellow POWER junction box junction box Fig 6 2 5 Connessione al segnale di controllo Per una maggiore stabilita amp consigliato impiegare un amplificatore di segnale DMX qualora si colleghino pi di 20 unit o il cavo di segnale sia maggiore di 60 m di lunghezza SIGNAL IN SIGNAL OUT junction box junction box Fig 7 Pins Functions Pin 1 Shield GND O Pin 2 Green Data input Pin 3 Red Data input 10 ARCGROUND36RGB 3 FUNZIONI E IMPOSTAZIONI 3 1 Funzionamento tramite controller ARCMAT Dopo aver effettuato il collegamento dell ARCGROUND36RGB all alimentazione 230V 50Hz collegare l unit al controller esterno ARCMAT attraverso il cavo di segnale Per ulteriori informazioni sul funzionamento del controller ARCMAT consultare il relativo manuale dedicato Power DMX OUTPUT Presa XLR Pin1 Massa Schermo Pin2 Negativo Pin3 Positivo Pin1 Massa Schermo Nero Pin2 Negativo Verde Pin3 Positivo Rosso CONNETTORE DI SEGNALE Fig 8 NOTA Connettere il controller ARCMAT alle unit disposte in serie che si desidera controllare Tutte le unit connesse all ARCMAT devono esse
27. ot press any buttons or do not assign any function for about a minute The controller has an LED display and 4 buttons to access the functions of the control panel fig 9 Note After a minute or two keystrokes the setting procedure is in standby mode Arch Work ArcMat O DOWN Fig 9 Button Instruction Used to turn on the ARCMAT The device will turn off automatically if one minute POWER 2 passes without pressing buttons or without assign function Used to access the menu DMX PERSON CALIB DIMMER STATIC SETTING See MENU section 3 3 Used to return a previous menu option Navigates downwards through the menu list and increases the numeric value UP when in a function DOWN Navigates upwards through the menu list and decreases the numeric value when in a function ENTER Used to access the menu or confirm the current function value or option within a menu 10 ARCGROUND36RGB 3 3 Menu structure ATTENTION for ARCGROUND36RGB are enabled on the controller only ARCMAT following functions DMX 001 512 ARC 1 ARC 1 D ARC FULL REMOTE SOLID SPECIAL 1 PERSON WHITEO1 WHITEO2 RED 000 255 GREN 000 255 BLUE 000 255 CALIB WHITE 11 RED 000 255 RGB TO W GRENI000 255 BLUE 000 255 OFF DIM 1 DIM 2 DIM 3 DIM 4
28. re settate allo stesso modo per poter funzionare corret tamente Impostare i parametri e le funzioni sulle unit attraverso il controller Si possono controllare contemporaneamente fino a 20 unit collegate in serie ARCGROUND36RGB 11 3 2 Impostazione base Per accendere VARCMAT inserire le 2 batterie da 1 5V incluse e premere il tasto POWER Per spegnere l ARCMAT invece non premere nessun tasto o non assegnare nessuna funzione per circa un minuto Il controller dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 9 Nota Dopo circa un minuto fra due pressioni dei tasti la procedura d impostazione entra in modalit standby Ach Work ArcMat O POWER O O DOWN Fig 9 Tasto Istruzioni POWER Tasto per l accensione dell ARCMAT Il dispositivo si spegner automaticamente se passer circa un minuto senza premere tasti o assegnare funzioni MENU Premendo questo tasto possibile selezionare la funzione desiderata DMX PERSON CALIB DIMMER STATIC SETTING Vedere paragrafo 3 3 Con questo tasto possibile anche tornare ad un opzione del MENU precedente UP Per scorrere attraverso le diverse funzioni in ordine discendente o aumentare il valore della funzione stessa DOWN Per scorrere attraverso le diverse funzioni in ordine ascendente o diminuire il valo re della funzione stessa ENTER Tasto per entrare
29. the original signals The termination has to be prepared by soldering a 1200 1 4 W resis tor on the last element of the DMX chain between pins 2 and 3 12 ARCGROUND36RGB 3 7 Tabella canali DMX Channel Function in ARC FULL mode nn Channel Function in ARC1 mode un RED 1 MASTER DIMMER 000 255 1 janes forage 2 RED 000 255 2 GREEN 0 100 000 255 3 GREEN 000 255 BLUE 3 0 100 000 255 4 BLUE 000 255 COLOR MACRO Channel Function in ARC1 D mode value No function 000 010 1 MASTER DIMMER R 100 G Up B 0 011 030 0 100 000 255 R Down G 100 B 0 031 050 An R 0 G 100 B Up 051 070 2 b R 0 G Down B 10006 071 090 97100 575 R Up G 0 B 100 091 110 GREEN R 100 G 0 B Down 111 130 3 0 100 000 255 R 100 G Up B Up 131 150 R Down G Down B 100 151 170 4 BLUE R 100 G 100 B 100 0 100 000 255 W 100 171 200 White 1 3200 K 201 205 FE DMX White 2 3400 K 206 210 Channel Function in SPECIAL 1 mode value White 3 4200 K 211 215 White 4 4900 K 216 220 1 MODULE 1 RED White 5 5600 K 221 225 0 100 000 255 White 6 5900 K 226 230 MODULE 1 GREEN White 7 6500 K 231 235 2 0 100 000 255 White 8 7200 K 236 240 White 9 8000 K 241 245 a MODULE 1 BLUE White 10 8500 K 246 250 0 100 000 255 White 11 10000 K 251 255 MODULE 2 RED STROBE 4 0 100 000
30. tivi ai canali rosso verde e blu 4 MANUTENZIONE 4 1 Pulizia sistema ottico e manutenzione Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qualificato Spegnere l unit scollegare il cavo di alimentazione ed aspettare finch l unit non si sia raffreddata Tutte le viti utilizzate per l installazione dell unit e le sue parti devono essere assicurate saldamente e non devono essere corrose Alloggiamenti elementi di fissaggio e di installazione devono essere totalmente esenti da qualsiasi de formazione I cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportare polvere fumo e altre particelle Solo cos la luce pu essere irradiata con la luminosit massima Per la pulizia usare un panno morbido pulito e un detergente per vetri come si trovano in commercio Quindi asciugare le parti delicatamente ARCGROUND36RGB TABLE OF CONTENTS Safety General instructions a 2 VVarnings and installation precautions aa General information ll 2 1 Description and technical specifications 1 1 Operating elements and connections 3 1 2 Description 4 1 3 Technical specifications 4 2 Installation 2 1 Mounting s s b As n 2 2
31. tup Switch off the unit unplug the main cable and wait until the unit has cooled down All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socket Use a soft clean cloth moistened with a mild detergent Then carefully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use a liquid it might pen etrate the unit and cause damage to it Place Stamp Here Affrancare Via Appia Km 136 200 Music amp Lights S r l 04020 Itri LT Italy Spett le 41V21411445 JALNVYVND VIZNVYYD Id OLVIIAILYTI 11 912311199 aazuesenb y yo uonezuasasd uo AjajOs passopua s aajueJenb y jo AUpijea y sasodind jje 104 uawdinba ay jo Jaumo 34140 Ayiqisuodsau 318 SJS juanbasqns pue 51502 yodsuely aajuesenb y u p pni ul jou ase syed ajqeAowad pue saYIMMS sa puey sduue syed jeusayxq juauidinba 24130 JU3W3e d31 BY 104 UOISIAOIA OU Saye SAJUBIEN y pasadwe u q sey
32. uale utente Music amp Lights S r l si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata Tutte le specifiche possono essere variate senza alcuna notifica 4 ARCGROUND36RGB ATTENZIONE Prima di effettuare qualsiasi operazione con l unit leggere con attenzione questo manuale e conservarlo accuratamente per riferimenti futuri Contiene informazioni importanti riguardo l installazione l uso e la manutenzione dell unit SICUREZZA Avvertenze generali prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Europea e pertanto recano la sigla C l dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle ope razioni descritte nel presente manuale esiste il pericolo di una scarica elettrica Eobbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di unefficiente messa a terra apparec chio di Classe secondo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contatti indiretti e o cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati Le operazioni di collegamento alla rete di distribuzione dell energia elettrica devono essere effettuate da un installa tore elettrico qualificato Verificare che frequenz
33. zionamento nel terreno HER Corretto Sbagliato Sbagliato Nota La copertura in acciaio non deve superare il terreno 3000 kg LARCGROUND36RGB stato pro gettato e testato per resistere ad un carico statico di 3000 kg in base alla copertura esterna i Fig 3 TUBO DI DRENAGGIO Linstallazione nel sottosuolo pu favorire la formazione di condensa all interno dell unit Per tale motivo l ARCGROUND36RGB dispone di una valvola in grado di bilanciare la pressione quando l unit si riscalda o si raffredda La valvola permette l ingresso nel dispositivo dell aria e impedisce quello dell acqua 8 ARCGROUND36RGB 2 2 Schema di cablaggio Svitare il coperchio della scatola di giunzione Raggiungere i morsetti per la connessione del cavo di alimentazione e di segnale e Inserire il cavo 6 8 mm attraverso la scatola di giunzione Seguendo le indicazioni riportate di seguito serrare i morsetti con il cavo e Ripristinare il coperchio della scatola di giunzione e avvitare 30 mm L 6 8 mm Morsetti DATA GND Black LIVE Black DATA Green EARTH Green DATA Red NEUTRAL White Fig 4 2 3 Regolazione del fascio luminoso bulloni che fissano il telaio al corpo devono essere completamente serrati in modo corretto alternando i bulloni diametralmente opposti Per facilitare l estrazione del vetro senza danneggiare la guarnizione mon tata sul telaio svitare tutti i dadi ad eccezi

Download Pdf Manuals

image

Related Search

Related Contents

The Coot User Manual - MRC Laboratory of Molecular Biology  dificuldades na compilação de um corpus de língua espanhola  Samsung MW73B User Manual  MANUEL D`UTILISATION  Gigabyte GA-7N400 Pro2  FX4 Series - Ruffneck Heaters  UPS KR-J Rack mount Series (1~3KVA) User`s Manual  《ニュートラルセッ トアップ方法》    UNE AGENCE D`ARCHITECTURE FORTEMENT  