1. PROLIGHTS is a brand of Music amp Lights S r l company 2013 Music amp Lights S r l PROLIGHTS un brand di propriet della Music amp Lights S r l
2. DIZUDADO Ip 1 JUOIZIPUO ajjap 01521 a Iqissod ar s yb p snummMm 0315 NS ajjp aspq ui DIZUDADD MODEL MODELLO SERIAL SERIE Purchased by Acquistato da SURNAME COGNOME C NAME NOME C ADDRESS VIA N E CITY CITTA ZIP CODE C A P PROV J D L S e S Dealer s stamp and signature Timbro e firma del Rivenditore b 4 Purchasing date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE MODEL MODELLO SERIAL SERIE N Purchased by Acquistato da SURNAME COGNOME NAME NOME ADDRESS VIA N C DE SES y CITY CITT j ZIP CODE C A P PROV Dealer s stamp and signature Timbro e firma del Rivenditore 9 gt Purchasing date Data acquisto FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE Music amp Lights S r l entertainment technologies Via Appia km 136 200 04020 Itri LT ITALY 50 9001 2008 tel 39 0771 72190 fax 39 0771 721955 Certified Company www musiclights it info musiclights it
3. Functions and settings 1 Operation 2 Basic 3 Menu structure 4 Dimmer mode 5 Special functions 6 Master Slave mode 7 Linking 8 DMX configuration 9 DMX addressing 10 Connection of the DMX line ww ww www www www 12 DMX control Maintenance 1 Maintenance and cleaning the unit 2 Fuse replacement 3 Troubleshooting BB u Appendix 1 Exploded view Warranty EVO90F Mount bracket Power cord User manual 3 Operating elements and connections 11 Construction of the DMX termination 10 10 11 11 12 12 13 13 14 15 15 16 17 2 EVOSOF WARNING Before carrying out any operations with the unit carefully read this instruction A manual and keep it with cure for future reference It contains important information about A the installation usage and maintenance of the unit SAFETY General instruction The products referred to in this manual conform to the European Community Directives and are there fore marked with ce The unit is supplied with hazardous network voltage 230V Leave servicing to skilled personnel only Never make any modifications on the unit not described in this instruction manual otherwise you will risk an electric shock Connection must be made to a power supply system fitted with efficient earthing Class appliance ac cording to standard EN 60598 1 It is moreover recommended to protect the supply lines of the units from indirect contact and or shortin
4. pud accedere dal pannello di controllo Premere il tasto MENU fino a quando sul display non appare SET quindi premere il tasto ENTER Attraverso i tasti UP e DOWN selezionare PERS e premere ENTER per confermare Selezionare la configurazione dei canali DMX che si desidera UNO DOS STD P attraverso i tasti UP e DOWN Le tabelle a pagina 16 indicano le modalit di funzionamento e i relativi valori DMX Come interfaccia DMX l unit possiede dei contatti XLR a 3 e 5 poli 3 9 INDIRIZZAMENTO DMX Per impostare l indirizzo DMX premere il tasto MENU fino a quando sul display non appare ADDR quindi premere il tasto ENTER Premere il tasto UP DOWN per selezionare il valore desiderato 001 512 tenere premuto invece il tasto UP DOWN per lo scorrimento veloce Altermine dell impostazione il valore verr salvato automaticamente Per poter comandare il dispositivo EVO90F con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per comandare la funzione del primo canale DMX si deve impostare sul proiettore EVO90F l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Segue un esempio con indirizzo 33 di start e una configurazione a 2 e 3 canali DMX Numero Indirizzo di Indirizzo DMX Prossimo indirizzo di start Prossimo indirizzo
5. sheet 34 LED boardd 7 Pulley 21 Driver board 35 Lens frame 8 Belt 22 Display PCB 36 052 collecting mirror 9 Pulley 23 PS socket male 37 Front plate shading cotton 10 Pulley shaft 24 Fuse holder 38 Shade leaf buckle of spindle 11 Bevel gear 25 PSinsulating heat conduct sheet 39 Shade leaf buckle mounting brac 12 Geat shaft 26 Power supply 40 Torsion spring 13 Knob 27 PSisolation sheet 41 Buckle 1 14 Adaptor PCB 28 M10 hand shank Place Stamp Here Affrancare Via Appia Km 136 200 Music amp Lights S r l 04020 Itri LT Italy Spett le 31V2I4IL832 JALNVYVND VIZNVYYD Id OLVIIAILYTI 912311199 y uonezuasasd uo 5 passopua s y Jo AUpijea y sasodind jje 104 ay jo Jaumo 34140 it Iqisuodsai 318 54511 juanbasqns pue 51502 140dsuej aajuesenb y ui p pnpu jou syed pue Sau21IMs so pueu sduue syed juauidinba 24130 JU3W3e d31 aui UOISIAOIA OU Saye y pe1jeduuei u q seu 1ueuudinbe y Jl 9AIDOIYO ou jm 99 Juawd nba 293 Jo Huljpuey 12 pue e uauedxeul Aq pesne siosjeg 31834411499 esjuejenb INO uo woy ay Bulpuas pue 1 Osje aq ue ay arsiu
6. 4 0m s 1129 16971 0 70m w 60m 60 7 60 s 501 754x 1 05m E S 8 0m 4 t 282 424lx 1 40m 3 10 0 30 30 SOM 307271 1 175m Eavg Emax Beam Angle 10 Beam Width Average Beam Angle 50 10 Vert Intensity ed Hori Intensity cd Fig 2 EVOSOF 1 3 ELEMENTI DI COMANDO E DI COLLEGAMENTO f EN STAFFA DI MONTAGGIO MANOPOLA DI FISSAGGIO per la staffa di montaggio CONTROLLO ROTATIVI PANNELLO DI CONTROLLO con display e 4 pulsanti per accesso e gestione delle diverse funzioni ALLOGGIAMENTO FUSIBILE in caso di rottura del fusibile sostituire sempre con uno dello stesso tipo e dello stesso valore POWER IN connettore di potenza Neutrik per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete 1 lt 2 9 m D I 5 7 ponen out He Fig 3 7 10 POWER OUT connettore di potenza Neutrik output alimentazione per connessione di pi unit in serie 13 unit a 220V DMX OUT XLR a 5 poli 1 massa 2 DMX 3 DMX 4 N C 5 N C DMX OUT XLR 3 poli 1 massa 2 DMX 3 DMX DMX IN XLR a 5 poli 1 massa 2 DMX 3 DMX 4 N C 5 N C DMX IN XLR 3 poli 1 massa 2 3 DMX EVOSOF 9 2 INSTALLAZIONE 2 1 MONTAGGIO Il proiettore EVO90F pu essere collocato su un piano solido Inoltr
7. EMI Anomalie Il proiettore non illumina Possibili cause Mancanza di alimentazione di rete Dimmer impostato a 0 LED difettoso i Scheda LED difettosa Controlli e rimedi Verificare la presenza della tensione alimentazione Incrementare i valori del canale dimmer Sostituire scheda LED Sostituire scheda LED Bassa intensit di luce generale Lentisporche Lente disallineata Pulire il dispositivo regolarmente Installare il gruppo ottico correttamente Il proiettore non alimentato Mancanza di alimentazione di rete Cavo di alimentazione danneggiato Alimentatore interno difettoso Verificare la presenza della tensione alimentazione Controllare il cavo di alimentazione Sostituire l alimentatore interno Il proiettore non risponde al DMX Indirizzamento DMX errato Cavo di segnale DMX difettoso Rimbalzo segnale DMX Controllare il pannello di controllo e l indirizzamento delle unit Controllare il cavo di segnale DMX Installare una terminazione DMX come suggerito Rivolgersi a un centro di assistenza tecnico autorizzato in caso di problema non riportato in tabella o che non possono essere risolti mediante la procedura riportata in tabella 5 APPENDICE 5 1 VISTA ESPLOSA EVOSOF 19 No ITEM No ITEM No ITEM 1 Shade leaf buckle 15 PS socket male 29 Leader 2 0150 Threa
8. LACK consente di attivare la modalit blackout in caso di errore DMX REST Selezionare la funzione REST per ripristinare i valori di default Per eseguire l operazione e necessario inserire la password MCON Selezionando la funzione MCON possibile caricare i dati DMX dall unit corrente Master alle unit Slave Selezionare MAST o SELF a seconda che si voglia rispettivamente abilitare o disabilitare il tra sfrimento dati DMX dall unit Master alle unit Slave 3 6 MODALIT MASTER SLAVE Questa modalit consente di collegare in linea pi unit EVO90F senza un controller La prima unit sar impostata come master e le altre funzioneranno come slave con lo stesso effetto Premere il MENU fino a quando sul display non appare RUN quindi premere ENTER per confermare Premere i tasti UP DOWN e selezionare la modalit SLAV Servirsi dei connettori DMX del EVO90F e di un cavo XLR per formare una catena di unit In certe con dizioni e lunghezze si consiglia di effettuare una terminazione come mostrato a pagina 15 3 7 COLLEGAMENTO 1 Collegare l uscita DMX OUT dell unit principale con l ingresso DMX IN della prima unit secondaria servendosi di un cavo XLR a 3 5 poli 2 Collegare l uscita DMX OUT della prima unit secondaria con l ingresso DMX IN della seconda unit secondaria ecc 14 EVOSOF 3 8 CONFIGURAZIONE CANALI DMX proiettore EVO90F dispone di diverse configurazioni canali DMX a cui si
9. PROFESSIONAL LIGHTS FRESNEL FIXTURE Music amp Lights S r l si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata Al fine di migliorare la qualit dei prodotti la Music amp Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it REV 001 04 13 INDICE Contenuto dell imballo EVOSOF Sicurezza Avvertenze generali Attenzioni e precauzioni per installazione Informazioni generali 1 Introduzione 1 1 Descrizione 1 2 Specifiche tecniche 1 3 Elementi di comando e di collegamento N Installazione 1 Montaggio Funzioni e impostazioni 1 Funzionamento 2 Impostazione base 3 Struttura menu 4 Modalit dimmer 5 Modalit setting 6 Modalit Master Slave 7 Collegamento 8 Configurazione canali DMX 9 Indirizzamento DMX 10 Collegamenti della linea DMX 11 Costruzione del terminatore DMX 12 Tabella canali DMX ww ww ww www ww ww Manutenzione 1 Manutenzione e pulizia del sistema ottico 2 Sostituzione fusibile 3 Risoluzione dei problemi SPAM u Appendice 1 Vista esplosa Certificato di garanzia EVO90F Staffa di
10. WN Per scorrere il menu Per entrare nel menu Per scorrere attraverso le Per scorrere attraverso le principale o tornaread selezionato o confermare il diverse funzioni in ordine diverse funzioni in ordine una opzione del menu valore attuale dellafunzioneo discendente o aumentare il ascendente diminuire il precedente l opzione all interno di un menu valore della funzione stessa valore della funzione stessa EVOSOF 11 3 3 STRUTTURA MENU MAIN FUNCTION SELECTION SUB SELECTION SUB SELECTION DESCRIPTION Dimmer DIM d 000 d 100 Manual control the intensity ofthe fixture DMX DMX Slave RUN To select the operating mode ofthe fixture SLAV DMX Address ADDR d001 d512 DMX starting address selection Off KEY Set the Key lock password mode On Off Dimming curve off Dim1 Dimming curve dim1 DIM Dim2 Dimming curve dim2 Dim3 Dimming curve dim3 Dim4 Dimming curve dim4 Off Adjust the shape of the Dimming curve off VI Adjust the shape of the Dimming curve 1 CURV v2 Adjust the shape of the Dimming curve 2 v3 Adjust the shape ofthe Dimming curve 3 Live Default mode which balances the requirements of tput and noi Special settings SET nn PERF Stdo Mode low power and maintains extremely low noise Powr Mode at high power for long periods of time Off SLCK Setting access lock On Uno PERS Dos Selects DMX Personality Std P uu Continues with last command
11. be of sufficient stability and be able to support a weight of 10 times of the unit s weight When carrying out any installation always comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm Adjust the projector and use the knob 2 to slightly release or tighten the locking mechanism of the bracket if is necessary 8 EVOSOF 3 FUNCTIONS AND SETTINGS 3 1 OPERATION Connect the supplied main cable to a socket 100 240 VAC 50 60 Hz Then the unit is ready for operation and can be operated via a DMX controller or it independently performs its show program in succession To switch off disconnect the mains plug from the socket For a more convenient operation it is recom mended to connect the unit to a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LED Display fig 5 ENTER DOWN Fig 5 MENU ENTER UP DOWN Used to access the Used to select and store the Navigates downwards Navigates upwards through menu or to return a current
12. biporsnurw Mw uo 31 aseydund nof Jaye uoos Juswd nba Jo adaid 291 51 ISP SUOI IPUOD euD ensqv irsyufipoisnurwMM ays Q M Jno Y JO UOISISA NJ ot puy Bunsixe ui yun y 5 291 DIzuDiDb 1 0102y11422 Jap 5 DIZUDID 0 maya 1 6 ap 2105525504 jap 031103 D ouos 2 Iu2su 12 OJIOASDA Ip 25285 aT WIgoyodsp a 116 aj 15 aj DIZUDID 05 0142234Dddb jjap 2 11505 DJ uou DIZUDIDD DT 01015 DIS O012224DddD onaya nid by uou DIZUDID D 0142234Dddb jjap uou osn pp a p zuodw DP nosno 150 6 15 25 QUOS 04334 NS JI 0301351631 ond arsiuBippisnurwMM 05 ns Jap 12041516 1 p 201d Ip orsinbab odop 15 DIZUDADY Ip I D49U9 JUOIZIPUO 01104153
13. cteristics of the fixture LIVE mode is the default mode which balances the requirements of output and noise 5700 mode maintains extremely low noise at all times and operates at a moderated power level POWR mode operates at high power for long periods of time without making considerations for noise levels SLCK Inthis function SLCK you can enable or disable the password to access the settings menu Select ON or OFF When the fixture is set as pass ON after 30 seconds or turn on the fixture next time the fixture will need an access password to enter in settings menu NOTE The factory access password is UP DOWN UP DOWN Press ENTER to confirm the access DERR Enter to DERR to control in case of DMX signal errors SAVE saves the latest data DMX on error DMX signal BLACK allows you to activate the mode on error DMX blackout REST In order to reset custom modes to default values select REST NOTE The factory access password is UP DOWN UP DOWN Press ENTER to confirm the access MCON The function MCON allows the user to select whether the fixture will send DMX data to other fixture during stand alone operation The MAST setting allows data to be sent to other fixtures The SELF setting is default and will not send DMX data to other fixtures 3 6 MASTER SLAVE MODE This mode will allow you to link up the units together without a controller Choose a unit to function as the Ma
14. d mirror 16 Display screen lens 30 Screw thread drive shaft 3 Silastic gasket 17 Plastic back cover 31 Fan 4 Front cover 18 Knob 32 Thermal switch 5 Adjust wheel 19 Control knob 33 Thermal switch holder 6 Adjust wheel shaft 20 Insulating heat conduction sheet 34 LED boardd 7 Pulley 21 Driver board 35 Lens frame 8 Belt 22 Display PCB 36 052 collecting mirror 9 Pulley 23 PS socket male 37 Front plate shading cotton 10 Pulley shaft 24 Fuse holder 38 Shade leaf buckle of spindle 11 Bevel gear 25 PSinsulating heat conduct sheet 39 Shade leaf buckle mounting brac 12 Geat shaft 26 Power supply 40 Torsion spring 13 Knob 27 PSisolation sheet 41 Buckle 1 14 Adaptor PCB 28 M10 hand shank All rights reserved by Music amp Lights S r l No part of this instruction manual may be reproduced in any form or by any means for any commercial use In order to improve the quality of products Music amp Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it TABLE OF CONTENTS Packing content EVOSOF Safety General instructions Warnings and installation precautions General information Introduction 1 Description 2 Technical specifications N Installation 1 Mounting N
15. d value 001 512 After the setting value is automatically saved To able to operate the EVO90F with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust the start address 33 on the EVO90F The other functions of the light effect panel are then automatically assigned to the following addresses An example with the start address 33 is shown below Number of Start address DMX Address Next possible start Next possible start Next possible start DMX channels example occupied address for unit No 1 address for unit No 2 address for unit No 3 2 33 33 34 35 37 39 3 33 33 35 36 39 42 DMX Address 33 DMX Address 36 DMX Address 39 DMX Address 42 Example 3 DMX channels configuration STD P mode Fig 7 EVOSOF 13 3 10 CONNECTION OF THE DMX LINE DMX connection employs standard XLR connectors Use shielded pair twisted cables with 1200 imped ance and low capacity The following diagram shows the connection mode DMX INPUT DMX OUTPUT XLR plug XLR socket Pin1 GND Shield fo fo Pin2 Negative Pin3 Positive Pin4 N C Pin5 N C Fig 8 ATTENTION The screened parts of the cable sleeve must never be connected to the system s earth as this would cause faulty fixture and controller operation Over long runs can be necessary
16. dendo l ambiente pi confortevole sia per i tecnici dietro il set che per i talents 1 2 SPECIFICHE TECNICHE I vantaggi della tecnologia offerta da EVO90F Risparmio energetico significativo in fase di funzionamento Risparmio nei cablaggi collegamento in serie di alimentazione e dmx fino a 16 Fresnel Nessun bisogno di Dimmer e lampade vita LED gt 50 000h Operazioni di manutenzione assenti ideale per luoghi difficilmente accessibili Adatto per accensioni di lunga durata Minor spesa per impianti di aria condizionata Compatibile con accessori standard in commercio Accessori e ricambi virtualmente indistruttibili Temperatura colore costante sull intera scala dimmer Flicker free in camera adatto per studi televisivi Assenza di emissioni UV IR e Intallazione in sicurezza anche in prossimit del pubblico o di oggetti delicati musei e teatro Interfaccia display LED ed elettronica con diagnostica calibrazione curva dimmer setup DMX Sorgente luminosa e ottica 9x10W LEDs array Lumen Tungsten 3090 Im Daylight 3708 Im Lux 10 Tungsten 6788 2m Daylight 8145 2m Peak intensity Tungsten 27000cd Daylight 32400cd Color rendering Tungsten gt 83Ra Daylight gt 70Ra Temperatura colore Tungsten 3100K Daylight 5600K Angolo di proiezione zoom 10 60 Gruppo ottico ad alta efficienza per massimizzare uniformit di proiezione precisione di focus stabilit temperat
17. di start Prossimo indirizzo di start canali DMX start esempio occupati possibile per unit n 1 possibile per unit n 2 possibile per unit n 3 2 33 33 34 35 37 39 3 33 33 35 36 39 42 DMX Address 33 DMX Address 36 DMX Address 39 DMX Address 42 Esempio di configurazione a 3 canali DMX modalit STD P Fig 7 EVOSOF 15 3 10 COLLEGAMENTI DELLA LINEA DMX La connessione DMX realizzata con connettori standard XLR Utilizzare cavi schermati 2 poli ritorti con impedenza 1200 e bassa capacita Per il collegamento fare riferimento allo schema di connessione riportato di seguito DMX INPUT DMX OUTPUT Spina XLR Presa XLR Pin1 Massa Schermo gra Gm Pin2 Negativo Pin3 Positivo Pin4 N C Pin5 N C Fig 8 ATTENZIONE La parte schermata del cavo calza non deve mai essere collegata alla terra dell impianto ci comporte rebbe malfunzionamenti delle unit e dei controller Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In tal caso sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poich non in grado di trasmettere in modo affidabile i dati di controllo DMX e Collegare l uscita DMX del controller con l ingresso DMX della prima unit Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di quella successiva e via dicendo finch tutte le unit sono col
18. does not light up EVOSOF Possible causes No mains supply Dimmer fader set to 0 Faulty LED Faulty LED board Checks and remedies Check the power supply voltage Increase the value of the dimmer channels Replace the LED board Replace the LED board General low light intensity Fixture does not power up Dirty lens assembly Misaligned lens assembly No power Loose or damaged power cord Faulty internal power supply Clean the fixture regularly Install lens assembly properly Check for power on power outlet Check power cord Replace internal power supply Fixture does not respond to DMX Wrong DMX addressing Damaged DMX cables Bouncing signals Check control panel and unit addressing Check DMX cables Install terminator as suggested Contact an authorized service center in case of technical problems or not reported in the table can not be resolved by the procedure given in the table 5 APPENDIX 5 1 EXPLODED VIEW EVOSOF 17 No ITEM No ITEM No ITEM 1 Shade leaf buckle 15 PS socket male 29 Leader 2 0150 Thread mirror 16 Display screen lens 30 Screw thread drive shaft 3 Silastic gasket 17 Plastic back cover 31 Fan 4 Front cover 18 Knob 32 Thermal switch 5 Adjust wheel 19 Control knob 33 Thermal switch holder 6 Adjust wheel shaft 20 Insulating heat conduction
19. e grazie alle possibilit di fissaggio sulla staffa fig 2 l unit pu essere montata anche a testa in gi su una traversa Per il fissaggio occorrono dei supporti robusti per il montaggio L area di collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza e Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta del proiettore non possa supe rare i 20 Orientare il proiettore intervenendo se necessario sulla manopola della staffa di montaggio 2 10 EVOSOF 3 FUNZIONI E IMPOSTAZIONI 3 1 FUNZIONAMENTO Per accendere l EVO9OF inserire la spina del cavo di alimentazione in una presa di rete 100 240V 50 60Hz L unit pu essere comandata da un unit DMX di comando luce oppure svolgere autonomamente il suo programma Per spegnere l EVO9OF staccare la spina dalla presa di rete Per maggiore comodit consi gliabile collegare l unit con una presa comandata da un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore EVO90F dispone di un display LED e 4 pulsanti per accesso alle funzioni del pannello di con trollo fig 5 ENTER DOWN Fig 5 MENU ENTER UP DO
20. fissaggio Cavo di alimentazione Manuale utente 10 10 11 12 12 13 13 14 14 15 15 16 17 17 18 19 4 EVOSOF ATTENZIONE Prima di effettuare qualsiasi operazione con l unit leggere con attenzione A questo manuale e conservarlo accuratamente per riferimenti futuri Contiene informazioni importanti riguardo l installazione l uso e la manutenzione dell unit SICUREZZA Avvertenze generali prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Europea e per tanto recano la sigla Il dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle operazioni descritte nel presente manuale esiste il pericolo di una scarica elettrica E obbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di un efficiente messa a terra apparecchio di Classe secondo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contatti indiretti e o cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati Le operazioni di collegamento alla rete di distribuzione dell energia elettrica devono essere effettuate da un installatore elettrico qualificato Verificare che frequenza e tensione della rete corrispondono alla frequenza ed alla tensione per cui l unit predisposta indicate sulla targhetta dei dati elettrici L unit non per uso domest
21. g to earth by using appropriately sized residual current devices The connection to the main network of electric distribution must be carried out by a qualified electrical installer Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label This unit is not for home use only professional applications Never use the fixture under the following conditions in places subject to vibrations or bumps in places with a temperature of over 45 C or 20 C Make certain that no inflammable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit is to be put out of operation definitively take it to a local recycling H plant for a disposal which is not harmful to the environment Warnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc Before starting any maintenance work or cleaning the projector cut off power from the main supply Always additionally secure the projector with the safety rope When carrying out any work always com ply scrupulous
22. gli schermi ultravioletti se danneggiati possono limitare la loro efficienza I LED devono essere sostituiti se danneggiati o termicamente deformati Non guardare direttamente il fascio luminoso Tenete presente che i veloci cambi di luce possono pro vocare attacchi d epilessia presso persone fotosensibili o epilettiche EVOSOF 5 INFORMAZIONI GENERALI Spedizioni e reclami Le merci sono vendute franco nostra sede e viaggiano sempre a rischio e pericolo del distributore clien te Eventuali avarie e danni dovranno essere contestati al vettore Ogni reclamo per imballi manomessi dovr essere inoltrato entro 8 giorni dal ricevimento della merce Garanzie e resi Il prodotto coperto da garanzia in base alle vigenti normative Sul sito www musiclights it possibile consultare il testo integrale delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia Music amp Lights constata tramite ve rifica sui resi la difettosit dichiarata correlata all appropriato utilizzo e l effettiva validit della garanzia provvede quindi alla riparazione dei prodotti declinando tuttavia ogni obbligo di risarcimento per danni diretti o indirett
23. i eventualmente derivanti dalla difettosit 6 EVOSOF 1 INTRODUZIONE 1 1 DESCRIZIONE EVO9O0F un proiettore Fresnel con sorgente LED della gamma Prolights ingegnerizzato per essere un alter nativa superiore in termini di performance e potenza ai fari convenzionali con lampada da 500W Disponibile nelle versioni Tungsten 3100K e Daylight 5600K EVO90F riproduce l omogeneit di proie zione e la linearit del dimmer dei fari convenzionali nonch le stesse modalit di utilizzo rendendolo un proiettore user friendly per lo staff tecnico La versatilit un fattore chiave per EVO90F in particolare la capacit di Focus regolabile manualmente in grado di passare da un fascio Spot 10 a Flood 60 in base alle esigenze se occorre un pullback shot o una proiezione potente su un punto stretto EVO90F offre la possibilit di modellare il fascio e tagliare il campo della luce dispersa grazie al set accessori di alette e bandiere EVO9OF si comporta esattamente come un faro tradizionale i risultati sono naturali ed il comportamento delle ombre il medesimo di un faro con sorgente singola Il funzionamento stato studiato per permettere di rimpiazzare i Fresnel tradizionali con le versione LED senza modificare gli impianti pre esistenti in studio La parte mancante rispetto gli illuminatori tradizionali risulta essere la produzione calore EVO90F infatti offre un funzionamento a freddo riducendo i costi di condizionamento e ren
24. ico solo per uso professionale Evitare di utilizzare l unit in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiore ai 45 C o inferiori a 20 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo X per lo smaltimento ad un istituzione locale per il riciclaggio Attenzioni e precauzioni per l installazione Se il dispositivo dovesse trovarsi ad operare in condizioni differenti da quelle descritte nel presente manuale potrebbero verificarsi dei danni in tal caso la garanzia verrebbe a decadere Inoltre ogni altra operazione potrebbe provocare cortocircuiti incendi scosse elettriche rotture etc Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull unit togliere la tensione dalla rete di alimentazione assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nell eseguire qual siasi intervento attenersi scrupolosamente a tutte le normative in materia di sicurezza vigenti nel paese di utilizzo Installare l unit in un luogo ben ventilato Mantenere i materiali infiammabili ad una distanza di sicurezza dall unit I filtri le lenti o
25. legate formando una catena Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze consigliato inserire sull ulti ma unit una terminazione DMX 3 11 COSTRUZIONE DEL TERMINATORE DMX La terminazione evita la probabilit che il segnale DMX 512 una volta raggiunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della catena con connettori XLR a 3 5 pin saldan do una resistenza di 1200 minimo 1 4W tra i terminali 2 e 3 cosi come indicato in figura Esempio connettore XLR a 3 pin 16 EVOSOF 3 12 TABELLA CANALI DMX UNO CH Function in UNO mode Value 1 DIMMER 0 100 000 255 005 CH Function in DOS mode Value 1 DIMMER 096 10096 000 255 2 FINE DIMMER 0 100 000 255 STD P CH Function in STD P mode Value 1 DIMMER 096 10096 000 255 gt FINE DIMMER 0 100 000 255 STROBE No strobe 000 009 Strobe slow to fast 010 099 3 Nostrobe 100 109 Lightning strobe slow to fast 110 179 No strobe 180 189 Random strobe slow to fast 190 255 EVOSOF 17 4 MANUTENZIONE 4 1 MANUTENZIONE E PULIZIA DEL SISTEMA OTTICO Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qualificato Spegnere l
26. ly with all the regulations particularly regarding safety currently in force in the country in which the fixture s being used Install the fixture in a well ventilated place Keep any inflammable material at a safe distance from the fixture Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed Never look directly at the light beam Please note that fast changes in lighting e g flashing light may trigger epileptic seizures in photosensitive persons or persons with epilepsy EVOSOF 3 GENERAL INFORMATION Shipments and claims The goods are sold ex works and always travel at the risk and danger of the distributor Eventual dam age will have to be claimed to the freight forwarder Any claim for broken packs will have to be forwarded within 8 days from the reception of the goods Warranty and returns The guarantee covers the fixture in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the va lidity of the guarantee is endorsed solely on presenta
27. menu or confirm the through the menu list and the menu list and decreases previous menu option current function value or option increases the numeric value the numeric value when in a within a menu when in a function function EVOSOF 9 3 3 MENU STRUCTURE MAIN FUNCTION SELECTION SUB SELECTION SUB SELECTION DESCRIPTION Dimmer DIM d 000 d 100 Manual control the intensity of the fixture DMX DMX Slave RUN To select the operating mode ofthe fixture SLAV DMX Address ADDR d001 d512 DMX starting address selection Off KEY Set the Key lock password mode On Off Dimming curve off Dim1 Dimming curve dim1 DIM Dim2 Dimming curve dim2 Dim3 Dimming curve dim3 Dim4 Dimming curve dim4 Off Adjust the shape of the Dimming curve off VI Adjust the shape of the Dimming curve 1 CURV v2 Adjust the shape of the Dimming curve 2 v3 Adjust the shape ofthe Dimming curve 3 Live Default mode which balances the requirements of tput and noi Special settings SET nn PERF Stdo Mode low power and maintains extremely low noise Powr Mode at high power for long periods of time Off SLCK Setting access lock On Uno PERS Dos Selects DMX Personality Std P uu Continues with last command upon loss of DMX DERR control Blak Black out fixture upon loss of DMX REST DE Reset fixture to factory defaults Self Not send DMX data to other fixture MCON Mast Send DMX data to other fi
28. ndom strobe slow to fast 190 255 EVOSOF 15 4 MAINTENANCE 4 1 MAINTENANCE AND CLEANING THE UNIT Make sure the area below the installation place is free from unwanted persons during setup Switch off the unit unplug the main cable and wait until the unit has cooled down screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots ceiling trusses suspensions should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socket Use a soft clean cloth moistened with a mild detergent Then carefully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use a liquid it might penetrate the unit and cause damage to it Warning we strongly recommend internal cleaning to be carried out by qualified personnel 4 2 FUSE REPLACEMENT 1 Remove the safety cap by screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and reconnect power USE Fig 10 16 4 3 TROUBLESHOOTING Problems Fixture
29. ngle 10 60 zoom High efficiency optics maximizing uniformity of projection framing precision color temperature sta bility over the entire dimming curve Average life LED life 250 000 hours EVOSOF 5 Electronics and features Several DMX configurations 1 2 channels 1 channel dimmer 2 channels dimmer dimmer fine 4 char LED display for control Dimmer curve setting 5 selectable configurations Flicker free frequency 2400 Hz diodes suitable for camera recording Quiet operations forced air cooling with no noise fans Structure and power supply High resistance aluminum body designed to facilitate heat dissipation Designed for compatibility with industry standard accessories Internal Protection IP20 Input Output Power connections Neutrik NAC3MPA NAC3MPB Input Output Signal connections 3p 5p XLR Suspension bracket rear handles and clamp levers designed for fast and easy mounting and pointing Power supply 100 240V 50 60Hz Operating conditions 20 45 C Power output for daisy chain connection of more units up to 16 projectors at 230V Max output consumption 100W Weight 5 5 kg Dimensions WxHxD 325x281x266 mm oo 1 Photometric data 10 Light Intensity Distribution 10 90 T I J 90 LA 2 0m T 5 4516 6788lx 0 35m a A 4 0m o 1129 16971 0 70m
30. sentano invece i diversi valori di velocit nella modalit non lineare DIM1 il valore pi veloce mentre DIM4 il pi lento CURV Selezionare la funzione CURV per regolare la forma della curva dimmer far riferimento al grafico ripor tato di seguito per la caratteristica di ciascuna curva CURV dimming 1 OFF ooo XCVI 3 CV3 T 4 CV4 40000 30000 20000 10000 EVOSOF 13 PERF Selezionando la funzione PERF possibile impostare le caratteristiche di prestazione del proiettore LIVE la modalit predefinita del proiettore e permette di bilanciare i requisiti di uscita e la rumo rosit del dispositivo 5700 la modalit che consente di ridurre estremamente il rumore del proiettore in ogni momento e di operare a un livello di potenza moderato POWR la modalit che consente di operare ad alta potenza per lungo tempo aumentando la rumorosit del proiettore SLCK Selezionando la funzione SLCK possibile attivare o disattivare la password di accesso al menu di impostazioni Selezionare ON OFF a seconda che si voglia rispettivamente abilitare o disabilitare la password Quando l unit impostata su bisogner immettere la password per accedere al menu impo stazioni DERR Selezionare la funzione DERR per la gestione in caso di errore del segnale DMX SAVE consente di salvare gli ultimi dati DMX in caso di errore del segnale DMX B
31. ster The unit must be the first unit in line other units will work as slave with the same effect Press the button MENU so many times until the display shows RUN and press the button ENTER Press UP DOWN to set the unit as slave SLAV Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units For longer cable runs we suggest a terminator at the last fixture see page 12 3 7 LINKING Several units may be interconnected in order to control all further slave units to the same effect of the master unit 1 Connect the DMX OUT of the master unit via 3 5 poles XLR cable to the DMX IN of the first slave unit 2 Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit etc until all units are connected in a chain 12 3 8 DMX CONFIGURATION EVO90F is equipped with different DMX configuration Press the button MENU so many times until shows SET and press the button ENTER to confirm Press the button UP DOWN to select PERS and press the button ENTER to confirm Selectthe desired DMX configuration UNO DOS STD P through the buttons UP and DOWN The tables on page 13 indicate the operating mode and DMX value The EVO90F is equipped with 3 5 poles XLR connections 3 9 DMX ADDRESSING Press the button MENU so many times until the display shows ADDR and press the button ENTER to confirm Press UP DOWN button to select the desire
32. tion of the guarantee certificate Music amp Lights will verify the validity of the claim through examination of the defect in relation to proper use and the actual validity of the guarantee Music amp Lights will eventually provide replacement or repair of the products de clining however any obligation of compensation for direct or indirect damage resulting from faultiness 4 EVOSOF 1 INTRODUCTION 1 1 DESCRIPTION EVO90F is a Fresnel fixture with LED source in Prolights range engineered to exceed conventional projec tors in performance and power creating a real opportunity to replace traditional 500W halogen projec tors Available in Tungsten 3100K and Daylight 5600K versions EVO90F reproduces the projection uniform ity and dimmer linearity of conventional projectors as well as same usage operations making it a user friendly projector for technical staff Versatility is a key factor of EVO90F ie the DMX controlled focusing function allowing transition from 10 spot to 60 flood beam moving from a pullback shot to a powerful projection on a narrow spot EVO90F and its set of barndoors allow control over beam shaping and light field cuts EVO90F response is exactly that of a conventional projector results are natural and shadows have same behaviour of single source spots Operations have been optimized allowing replacement of traditional Fresnel luminaries with these LED powered ones with no change to pre existing studio set
33. to insert a DMX level matching amplifier For those connections the use of balanced microphone cable is not recommended because it cannot transmit control DMX data reliably Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit 3 11 CONSTRUCTION OF THE DMX TERMINATION The termination avoids the risk of DMX 512 signals being reflected back along the cable when they reach es the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination is prepared by soldering a 1200 1 4 W resistor between pins 2 and 3 ofthe 5 pin male XLR connector as shown in figure Example 3 pin XLR connector 14 EVOSOF 3 12 DMX CONTROL UNO CH Function in UNO mode Value 1 DIMMER 0 100 000 255 005 CH Function in DOS mode Value 1 DIMMER 096 10096 000 255 2 FINE DIMMER 0 100 000 255 STD P CH Function in STD P mode Value 1 DIMMER 096 10096 000 255 gt FINE DIMMER 0 100 000 255 STROBE No strobe 000 009 Strobe slow to fast 010 099 3 Nostrobe 100 109 Lightning strobe slow to fast 110 179 No strobe 180 189 Ra
34. unit scollegare il cavo di alimentazione ed aspettare finch l unit non si sia raffreddata Tutte le viti utilizzate per l installazione dell unit e le sue parti devono essere assicurate saldamente e non devono essere corrose Alloggiamenti elementi di fissaggio e di installazione soffitto truss sospensioni devono essere total mente esenti da qualsiasi deformazione cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportare polvere fumo e altre particelle Solo cos la luce pu essere irradiata con la luminosit massima Per la pulizia usare un panno morbido pulito e un detergente per vetri come si trovano in commercio Quindi asciu gare le parti delicatamente Attenzione consigliamo che la pulizia interna sia eseguita da personale qualificato 4 2 SOSTITUZIONE FUSIBILE 1 Assicurarsi di scollegare il cavo di alimentazione del proiettore prima di sostituire un fusibile bruciato con uno dello stesso tipo Conun cacciavite rimuovere il portafusibile dalla sua sede e il fusibile bruciato dal suo supporto sosti tuire il fusibile con uno identico per tipologia e valore T3 15A Inserire il portafusibile al suo posto e ricollegare l alimentazione EUSA XA Fig 10 18 EVOSOF 4 3 RISOLUZIONE DEI PROBL
35. upon loss of DMX DERR control Blak Black out fixture upon loss of DMX REST DE Reset fixture to factory defaults Self Not send DMX data to other fixture MCON Mast Send DMX data to other fixture 12 EVOSOF 3 4 MODALIT DIMMER Questa modalit permette di regolare manualmente l intensit del proiettore Premere il tasto MENU fino a quando sul display non appare DIM quindi premere ENTER per confer mare Utilizzare i tasti UP DOWN per selezionare il valore di intensit desiderato d 000 d 100 Premere il tasto ENTER per salvare l impostazione 3 5 MODALIT SETTING Premere il tasto MENU e selezionare attraverso i tasti direzionali la voce SET per confermare premere il tasto ENTER possibile accedere alle seguenti funzioni KEY Selezionando la funzione KEY possibile attivare o disattivare la password di accesso Selezionare ON o OFF a seconda che si voglia rispettivamente abilitare o disabilitare la password Quando l unit impostata su dopo 30 secondi o al prossimo riavvio bisogner immettere la password di accesso NOTA Le impostazioni di fabbrica relative alla password di accesso corrispondono alla combina zione dei tasti UP DOWN UP DOWN Premere ENTER per confermare DIMM Selezionare la funzione DIMM per entrare nella modalit dimmer e scegliere e simulare diverse veloci t dimming In particolare quando impostato su OFF il dimmer e lineare DIM1 2 3 4 rappre
36. ups Compared to traditional projectors EVO90F is only lacking in heat generation it is characterized by cold working operations reducing need and cost of air conditioning in studios and implying a more comfort able environment for both talents and technicians 1 2 TECHNICAL SPECIFICATIONS Advantages of EVO90F technology e Considerable energy saving during operation Simplified wiring up to 16 Fresnel in a daisy chain for both power and signal connection No need for dimmers nor lamp replacement LED lifespan gt 50 000h No maintenance operations ideal when placed out of reach Suitable for long lasting operations Cost effective lower need for typical air conditioned studio requirements Working with industry standard accessories Virtually indestructible accessories and parts Constant colour temperature over the whole dimming scale Flicker free for cameras TV studios friendly NoUV IR emissions No harm installation in proximity of audience TV theaters or light sensitive objects museums User friendly LED display interface for dimming curve calibration DMX setup and self test Light source and optics 9x10W LEDs array Lumen Tungsten 3090 Im Daylight 3708 Im Lux 10 Tungsten 6788 2m Daylight 8145 2m Peak intensity Tungsten 27000 Daylight 32400cd Color rendering Tungsten gt 83Ra Daylight gt 70Ra Color Temperature Tungsten 3100K Daylight 5600K Beam a
37. ura colore sull intera curva dimmer Durata media vita LED gt 50 000 ore EVOSOF 7 Funzionamento ed elettronica Diverse configurazioni DMX disponibili 1 2 canali canale dimmer 2canali dimmer dimmer fine Interfaccia di controllo mediante display LED 4 char Regolazione curva dimmer 5 configurazioni selezionabili Frequenza dei diodi anti flicker gt 400Hz adatta per ripresa in camera Silenziosit di funzionamento ventilazione ad aria forzata con ventole silenziate Corpo e alimentazione Corpo in alluminio ad alta resistenza progettato per facilitare la dissipazione termica Progettato per essere compatibile con accessori standard in commercio Ambiente IP20 Connessioni di alimentazione Input Output Neutrik NAC3MPA NAC3MPB Connessioni di segnale Input output XLR3p 5p Staffa di sospensione maniglie posteriori e leve di serraggio ideate per facilitare e velocizzare le fasi di montaggio e puntamento Alimentazione 100 240V 50 60Hz Condizioni di esercizio 20 45 Output alimentazione per connessione di pi unit in serie fino a 16 proiettori a 230V Consumo ad emissione massima 100W Peso 5 5 kg Dimensioni LxAxP 325x281x266 mm oo 1 Diagramma di luminosit 10 Light Intensity Distribution 10 90 T I J 90 A gt c 2 0m 25 5 4516 67881 0 35m a A
38. w 60m 60 60 g 501 754x 1 05m 5 S 8 0m 4 t 282 424lx 1 40m 3 10 0 30 30 SOM 07271 1 175m Eavg Emax Beam Angle 10 Beam Width Average Beam Angle 50 10 Ven Intensity ce Intensity cd Fig 2 1 3 OPERATING ELEMENTS AND CONNECTIONS Bw NS EVOSOF f N MOUNTING BRACKET LOCKING KNOB for the mounting bracket ROTARY CONTROL CONTROL PANEL with display and 4 button used to access the control panel functions and manage them FUSE OLDER in the event of breakage always replace the fuse with the same type and rating POWER IN Neutrik connector for connection to a socket 100 240V 50 60Hz via the supplied mains cable 7 10 lt lt 1 lt 2 3 2 om DE 5 7 He Fig 3 POWER OUT Neutrik connector power output for connection of multiple units in series 13 units 220V DMX OUT 5 pole XLR 1 ground 2 DMX 3 DMX 4 N C 5 N C DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX DMX IN 5 pole XLR 1 ground 2 DMX 3 DMX 4 N C 5 N C DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX EVOSOF 7 2 INSTALLATION 2 1 MOUNTING 9 may be set up on a solid and even surface The unit can also be mounted upside down to a cross arm For fixing stable mounting clips are required The mounting place must
39. xture 10 EVOSOF 3 4 DIMMER MODE This mode allows the user to manually control the intensity of the fixture Press the button MENU so many times until shows DIM and press the button ENTER to confirm Press the button UP DOWN to select Fix c then press ENTER to confirm Using UP DOWN button select the desired value d 000 4 100 Press ENTER button to confirm 3 5 SPECIAL FUNCTIONS Press the button MENU and select through the directional buttons the SET mode and press the button ENTER to confirm It is possible to view to following functions KEY Enter the KEY mode to select whether the access password is on or off Select ON or OFF When the fixture is set as pass ON after 30 seconds or turn on the fixture next time the fixture will need an access password to enter the display menu control NOTE The factory access password is UP DOWN UP DOWN Press ENTER to confirm the access DIM Enter to DIM to select specific dimming curve When dimmer is set to OFF the dimmer is linear DIM1 2 3 4 are speed modes of the linear dimmer DIM1 is the faster while DIM4 is the slowest CURV Enter to CURV to adjust the sha e of the dimming curve See the CURV chart to understand more about actual dimming curves CURV dimming 1 OFF m 3 T 4 CV4 40000 30000 20000 10000 EVOSOF 11 PERF Enter to mode PERF you can set the performance chara