Home
Manuale Utente User Manual LUMIPAR18QPRO
Contents
1. MENU LEVEL 1 LEVEL 2 LEVEL 3 REMARK 1 Auto Auto Speed 5 Automatic programs lt Auto1 gt lt Auto1 gt lt 100 gt lt Auto2 gt lt 100 gt lt Auto3 gt lt 100 gt lt Auto4 gt lt 100 gt lt Auto5 gt lt 100 gt 2 Static Static Fix C lt FixC gt lt R Red gt Green lt B gt Blue lt W gt White lt GB gt Green Blue lt R B gt Red Blue lt RG Red Green lt RGB gt Red Green Blue W gt Red White lt G W gt Green White x BW gt Blue White lt RG W gt Red Green White lt R BW gt Red Blue White lt GBW gt Green Blue White lt RGBW gt Red Green Blue White lt Manu C gt Manual C lt R 255 gt lt 62555 Combine red green blue and white to make a custom color lt B 255 gt lt W 255 gt 3 Dim Mode Dim Mode lt DIM1 gt lt Off gt Default On lt DIM1 gt DIM 1 Dimmer speed fast 0 8 s lt DIM2 gt DIM 2 Dimmer speed middle 1 6 5 lt DIM3 gt DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite lt 0n gt lt n gt Default On lt 105 gt 10 s Off after 10 seconds lt 205 gt 20 s Off after 20 seconds lt 305 gt 30 s Off after 30 seconds 5 Info Auto Auto Test Test LUMIPAR IBOPRO 11 Fix Hours Fixture running time 0 9999H lt 0H gt Default 0H Version lt V1 1 gt Address Address DMX address 001 512 lt 001 gt lt 512 gt Channel Channel DMX Channel 40 40 lt 5h gt lt 10Ch
2. Fix Hours Fixture running time 0 9999H lt 0H gt Default 0H Version lt V1 1 gt Address Address DMX address 001 512 lt 001 gt lt 512 gt Channel Channel DMX Channel 40 40 lt 5h gt lt 10Ch gt M amp S Mode M amp S Mode lt Master gt lt Master gt lt Slave gt White Balance Value Balance lt R 255 gt lt R 125 255 gt lt G 255 gt lt G 125 255 gt lt B 255 gt lt B 125 255 gt 10 LUMIPAR IBOPRO 3 4 AUTO SHOW MODE If no DMX control signal is present at the DMX INPUT the unit independently runs through its show pro gramme provided that the blackout mode is switched off Press the button MENU so many times until the display shows AUTO then press the button ENTER Press the button UP DOWN to switch between the show AUTO 1 AUTO 5 The unit will operate in show mode Using the button UP DOWN to select the desired run speed slow fast 0 100 Press the button ENTER to save the setting IMPORTANT Programs AUTO 1 AUTO 5 are fully pre programmed and will not be altered by changes Instead MANUC mode allows to combine red R green G blue B and white W Press the button MENU so many times until the display shows STATIC then press the button ENTER Through the button UP DOWN select MANU then press the button ENTER Select the color WarmWhite R G B W through the buttons UP DOWN Press the button ENTER to confirm Set the value 000 255
3. Number of Start address DMX Address Next possible start Next possible start Next possible start DMX channels example occupied address for unit No 1 address for unit No 2 address for unit No 3 10 33 33 42 43 53 63 DMX Address 33 DMX Address 43 DMX Address 53 DMX Address 63 Example 10 DMX channels configuration Fig 5 12 LUMIPAR IBOPRO 3 10 CONNECTION OF THE DMX LINE DMX connection employs standard XLR connectors Use shielded pair twisted cables with 1200 imped ance and low capacity The following diagram shows the connection mode DMX INPUT DMX OUTPUT XLR plug XLR socket An Pin1 GND Shield Pin2 Negative Pin3 Positive Fig 6 ATTENTION The screened parts of the cable sleeve must never be connected to the systems earth as this would cause faulty fixture and controller operation Over long runs can be necessary to insert a DMX level matching amplifier For those connections the use of balanced microphone cable is not recommended because it cannot transmit control DMX data reliably Connect the controller DMX input to the DMX output of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit 3 11 CONSTRUCTION OF THE DMX TERMINATI
4. 16 LUMIPAR IBOPRO 3 13 FUNZIONI DISPOSITIVO Per il LUMIPAR18QPRO possibile accedere alle seguenti funzioni dispositivo Dimmer Per entrare nella modalit dimmer e scegliere e simulare diverse curve dimming premere il tasto MENU ripetutamente fino a quando sul display non compare DIM MODE quindi premere il tasto ENTER Premere il tasto UP DOWN per selezionare Off DIM1 DIM2 DIM3 Premere il tasto ENTER per confermare la scelta Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di im postazione BackLite Per regolare il tempo della retroilluminazione display premere il tasto MENU ripetutamente fino a quando sul display non compare BACKLITE quindi premere il tasto ENTER Premere il tasto UP DOWN per selezionare On 10S 20S 30S Premere il tasto ENTER per confermare la scelta Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di im postazione 3 14 INFORMAZIONI SUL DISPOSITIVO Auto Test Permette di verificare il corretto funzionamento dell unit Per avviare il test procedere nel seguente modo Premere il tasto MENU ripetutamente fino a quando sul display non compare INFO quindi premere ENTER per confermare Selezionare attraverso i tasti UP DOWN la funzione AUTO TEST Per confermare e dare l avvio al test automatico premere il tasto ENTER FixHours Permette di visualizzare le ore di funz
5. Manutenzione 1 Manutenzione e pulizia del sistema ottico 2 Sostituzione fusibile 3 Risoluzione dei problemi Certificato di garanzia LUMIPAR18QPRO Staffa di fissaggio 2pz Cavo di alimentazione Manuale utente A 10 12 12 12 12 13 13 14 14 15 16 16 17 18 18 18 4 LUMIPAR IBOPRO ATTENZIONE Prima di effettuare qualsiasi operazione con l unit leggere con attenzione A questo manuale e conservarlo accuratamente per riferimenti futuri Contiene informazioni importanti riguardo l installazione l uso e la manutenzione dell unit SICUREZZA Avvertenze generali prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunit Europea e per tanto recano la sigla ce Il dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle operazioni descritte nel presente manuale esiste il pericolo di una scarica elettrica obbligatorio effettuare il collegamento ad un impianto di alimentazione dotato di un efficiente messa a terra apparecchio di Classe secondo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contatti indiretti e o cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati Le operazioni di collegamento alla rete di distribuzione dell energia elettrica devono essere effettuate da un installatore elettrico qualificato Verific
6. 255 attraverso i tasti UP DOWN quindi premere il tasto ENTER Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di impostazione 3 5 MODALIT STATIC L unit dispone di preset colori pre programmati che possono essere impostati attraverso la seguente procedura Per entrare nella modalit static premere il tasto MENU ripetutamente fino a quando sul display non appare STATIC quindi premere ENTER per confermare Utilizzare i tasti UP DOWN per selezionare la funzione preset color FIXT C quindi premere ENTER per confermare Selezionare il preset color desiderato R G B W GB RB RG RGB RW GW BW RGW RBW GBW RGBW attraverso i tasti UP DOWN Premere il tasto ENTER per salvare l impostazione 3 6 MODALIT MASTER SLAVE Questa modalit consente di collegare in linea pi unit LUMIPAR18QPRO senza un controller La prima unit sar impostata come master e le altre funzioneranno come slave con lo stesso effetto Premere il tasto MENU fino a quando sul display non appare M amp S quindi premere il tasto ENTER Premere i tasti UP DOWN e selezionare la modalit MASTER SLAVE per impostare le unit come master o slave Premere il tasto ENTER per confermare Sull unita master selezionare il programma desiderato come indicato al paragrafo 3 4 Servirsi dei connettori DMX del LUMIPAR18QPRO e di un cavo XLR per formare una catena di unit In ce
7. Set the value 125 255 through the buttons UP DOWN Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati cally 16 LUMIPAR IBOPRO 4 MAINTENANCE 4 1 MAINTENANCE AND CLEANING THE UNIT Make sure the area below the installation place is free from unwanted persons during setup Switch off the unit unplug the main cable and wait until the unit has cooled down AII screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots ceiling trusses suspensions should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected It is recommended to clean the front at regular intervals from impurities caused by dust smoke or other particles to ensure that the light is radiated at maximum brightness For cleaning disconnect the main plug from the socket Use a soft clean cloth moistened with a mild detergent Then carefully wipe the part dry For cleaning other housing parts use only a soft clean cloth Never use a liquid it might penetrate the unit and cause damage to it 4 2 FUSE REPLACEMENT FODE 1 Remove the safety cap by a screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and reconnect power 7 4 3 TROUBLESHOOTING Fig
8. 4 3 RISOLUZIONE DEI PROBLEMI Possibili cause Controlli e rimedi Mancanza di alimentazione di rete Verificare la presenza della tensione alimentazione Dimmer impostato a0 nqementare i valori del canale dimmer Il proiettore non illumina Tutti i colori impostati a 0 Incrementare i valori dei canali colori LED difettoso i Sostituire scheda LED Scheda LED difettosa Sostituire scheda LED Lenti sporche Pulire il dispositivo regolarmente Bassa intensit di luce generale Lente disallineata Installare il gruppo ottico correttamente Mancanza di alimentazione di rete Cavo di alimentazione danneggiato Alimentatore interno difettoso Verificare la presenza della tensione alimentazione Controllare il cavo di alimentazione Sostituire l alimentatore interno Il proiettore non alimentato ndirizzamento DMX errato Controllare il pannello di controllo e l indirizzamento delle unit Controllare il cavo di segnale DMX Installare una terminazione DMX come suggerito Il proiettore non risponde al DMX avo di segnale DMX difettoso Rimbalzo segnale DMX A Rivolgersi a un centro di assistenza tecnico autorizzato in caso di problema non riportato in tabella o che non possono essere risolti mediante la procedura riportata in tabella All rights reserved by Music amp Lights S r l No part of this instruction manual may be reproduced in any form or by any means for any commerc
9. 8 Problems Possible causes Checks and remedies No mains supply Check the power supply voltage Dimmer fader set to 0 Increase the value of the dimmer channels Fixture does not light up All color faders set to 0 Increase the value of the color channels Faulty LED Replace the LED board Faulty LED board Replace the LED board ere Dirty lens assembly Clean the fixture regularly General low light intensity Misaligned lens assembly Install lens assembly properly No power Check for power on power outlet Fixture does not power up Loose or damaged power cord Check power cord Faulty internal power supply Replace internal power supply Wrong DMX addressing Check control panel and unit addressing Fixture does not respond toDMX Damaged DMX cables Check DMX cables Bouncing signals Install terminator as suggested Contact an authorized service center in case of technical problems or not reported in the table can not be resolved by the procedure given in the table Place Stamp Here Affrancare Via Appia Km 136 200 Music amp Lights S r l 04020 Itri LT Italy Spett le 41V21411445 JALNVYVND VIZNVYYD 104 OLVIIAILYTI 11 2 aajuesenb aY1 yo uoljejuasaid uo Ajajos passopua s aazuesenb y jo AUpijea y sasodind ile 104 Quawdinba ay Jo JaUMO 2Y140 Ayiqisuodsau ase S si juanbasqns pue 51502 yodsuel aajuesenb y ul p pni ul jou ase syed ajq
10. Music amp Lights constata tramite ve rifica sui resi la difettosit dichiarata correlata all appropriato utilizzo e l effettiva validit della garanzia provvede quindi alla riparazione dei prodotti declinando tuttavia ogni obbligo di risarcimento per danni diretti o indiretti eventualmente derivanti dalla difettosit 6 LUMIPAR IBOPRO 1 INTRODUZIONE 1 1 DESCRIZIONE LUMIPAR18QPRO un ParLED per utilizzo professionale dal corpo super slim concepito per essere un potente wash light in applicazione Rental Touring La sorgente luminosa si compone di 18x8W RGBW FC LEDs ad alta efficienza concepita offrire una generazione cromatica avanzata con pieno controllo sulla saturazione e temperatura del colore Il design ultra sottile ed il funzionamento privo di ventole rendono LUMIPAR18QPRO un innovazione rispetto ai tradizionali proiettori a fusto PAR offrendo una maggiore ver satilit rapidit di montaggio e cablaggio facilit di trasporto 1 2 SPECIFICHE TECNICHE Sorgente luminosa e ottica 18x 8W RGBVV FC LED ad alta resa luminosa e Angolo di proiezione 19 Angolo di campo 38 Preset temperatura colore bianco 3200K 10 000K Sistema di sintesi colore miscelazione RGBW FullColor 516 milioni di colori Durata media diodi LED gt 50 000 ore Funzionamento ed elettronica Pannello di controllo tramite display LCD Diverse configurazioni DMX disponibili 4 5 10 canali per controllo professionale o sem
11. OUT o oo O lt FUSE T3 15A 240V 0690869000 KW o STAFFA DI MONTAGGIO MANOPOLA DI FISSAGGIO per la staffa di montaggio DMX OUT XLR a 3 poli 1 massa 2 DMX 3 DMX DMX IN XLR a 3 poli 1 massa 2 DMX 3 DMX PANNELLO DI CONTROLLO con display e 4 pulsanti per accesso e gestione delle diverse funzioni Fig 1 POWER IN connettore di potenza Neutrik per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione POWER OUT connettore di potenza Neutrik output alimentazione per connessione di pi unit in serie PORTAFUSIBILE sostituire un fusibile difettoso solo con uno dello stesso tipo SAFETY EYE per l aggancio al cavo di sicurezza 8 LUMIPAR IBOPRO 2 INSTALLAZIONE 2 1 MONTAGGIO II LUMIPAR18QPRO pu essere collocato su un piano solido Inoltre grazie alle possibilit di fissaggio sulla doppia staffa fig 2 l unit pu essere montata anche a testa in gi su una traversa Per il fissaggio oc corrono dei supporti robusti per il montaggio L area di collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza e Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea assolutamente necessario assicur
12. and temperature The ultra thin design and the absence of fans make LUMIPAR18QPRO a big innovation compared to tradi tional Parcans offering higher versatility easy setup and reduced carrying volume 1 2 TECHNICAL SPECIFICATIONS Light source and optics 18 x 8VV RGB FC high power LED Beam angle 19 Field angle 38 White color temperature preset 3200K 10 000K e Colour synthesis RGB FullColor colour mixing gt 16 million colours LEDs average life span gt 50 000 hours Electronics and features User panel through LED display Several DMX selectable configurations 4 5 10 channels for advanced or basic controlling Achannels RGBW 5channels Dimmer RGBW 10 channels Dimmer RGBW strobe macro auto auto speed dimmer curve Dimmer curve setting 3 selectable configurations Auto mode built in programs with execution speed adjustment Static colour mode selection of static colour Master Slave mode for synchronized operation of more units linked in a chain Linear and stepless transition between DMX values Flicker free operations 400Hz Structure and power supply Sturdy die cast aluminium body IP54 Silent operations due to natural cooling of the peculiar chassis and to absence of fans e Double hanging bracket suitable for safe hanging and for floor positioning Power unit 100 240V 50 60Hz IN OUT wiring signal and power connections through XLR3p Powercon Average power
13. consumption 125W up to 8 projectors output Weight 5 kg e Dimensions WxHxD 302x239x259mm LUMIPAR IBOPRO 5 1 3 OPERATING ELEMENTS AND CONNECTIONS oo MENU UP DOWN ENTER ooooooooooooooo 00000000000000000 00000000000000000 oo oo 2 POWER IN 100 240V AC 50 60Hz oo OO 4 POWER OUT o 069089000 Fig 1 MOUNTING BRACKET LOCKING KNOB for the mounting bracket DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX CONTROL PANEL with display and 4 button used to access the control panel functions and manage them POWER IN Neutrik connector for connection to a socket 100 240V 50 60Hz via the supplied mains cable POWER OUT Neutrik connector power output for connection of multiple units in series MAIN FUSE HOLDER replace a burnt out fuse by one of the same type only SAFETY EYE to attach safety cable 6 LUMIPAR IBOPRO 2 INSTALLATION 2 1 MOUNTING LUMIPAR18QPRO may be set up on a solid and even surface The unit can also be mounted upside down to a cross arm For fixing stable mounting clips are required The mounting place must be of sufficient stability and be able to support a weight of 10 times of the weight When carrying out any i
14. gt M amp S Mode M amp S Mode lt Master gt lt Master gt lt Slave gt White Balance Value Balance lt R 255 gt lt R 125 255 gt lt G 255 gt lt G 125 255 gt lt B 255 gt lt B 125 255 gt 12 LUMIPAR IBOPRO 3 4 MODALIT AUTO SHOW Se alla presa DMX non presente alcun segnale di comando DMX l unit pu svolgere il suo programma Show autonomamente Premere il tasto MENU fino a quando sul display non appare AUTO quindi premere il tasto ENTER Premere il tasto UP DOWN per scorrere al programma show desiderato AUT01 AUT05 e confermare con il tasto ENTER L unit entrer in modalit automatica mandando in esecuzione lo show selezionato per il quale possibile regolare la velocit di esecuzione SPEED Attraverso i tasti UP DOWN selezionare la velocit di esecuzione desiderata slow fast 0 100 Premere ENTER per salvare l impostazione IMPORTANTE programmi AUTO 1 AUTO 5 sono completamente pre programmati e non possono essere modificati Invece la modalit MANU C consente di creare gamme di colori combinando insieme il colore rosso R verde G blu B e bianco W Premere il tasto MENU fino a quando sul display non appare STATIC quindi premere il tasto ENTER Attraverso i tasti UP DOWN selezionare MANU quindi premere il tasto ENTER e Selezionare il colore R G B W attraverso i tasti UP DOWN Per confermare premere il tasto ENTER Impostare i valori 000
15. paese di utilizzo Installare l unit in un luogo ben ventilato Mantenere i materiali infiammabili ad una distanza di sicurezza dall unit I filtri le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro efficienza I LED devono essere sostituiti se danneggiati o termicamente deformati Non guardare direttamente il fascio luminoso Tenete presente che i veloci cambi di luce possono pro vocare attacchi d epilessia presso persone fotosensibili o epilettiche Non toccare l alloggiamento del prodotto quando in funzione perch potrebbe essere molto caldo LUMIPAR IBOPRO 5 INFORMAZIONI GENERALI Spedizioni e reclami Le merci sono vendute franco nostra sede e viaggiano sempre a rischio e pericolo del distributore clien te Eventuali avarie e danni dovranno essere contestati al vettore Ogni reclamo per imballi manomessi dovr essere inoltrato entro 8 giorni dal ricevimento della merce Garanzie e resi Il prodotto coperto da garanzia in base alle vigenti normative Sul sito www musiclights it possibile consultare il testo integrale delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia
16. the MENU button to go back or to meet the waiting time to exit from the setup menu auto matically 3 14 FIXTURE INFORMATION Auto Test Allow checking the proper functioning of the unit Start the automatic test in the following way Press the button MENU so many times until shows INFO then press the ENTER button to confirm Using the button UP DOWN to select AUTO TEST To confirm and start the automatic test press the ENTER button FixHours Show the fixture working hours Press the button MENU so many times until shows INFO Press the button ENTER to confirm Using the button UP DOWN to select FIXHOURS then press the button ENTER to confirm Then the display will show the working hours Press the MENU button to go back or to meet the waiting time to exit from the setup menu auto matically Version Show the fixture firmware version Press the button MENU so many times until shows INF0 Select through the button UP DOWN the VERSION menu voice e The display will show the firmware data Press the MENU button to go back or to meet the waiting time to exit from the setup menu automatically LUMIPAR IBOPRO 15 3 15 WHITE CALIBRATION Enter the White balance to adjust the RGB parameter to make different whites Press the button MENU so many times until shows WHITE BALANCE and press the button ENTER to con firm Select R G and B through the buttons UP DOWN Press MENU button to confirm
17. through the buttons UP DOWN Press the MENU button to go back or to meet the waiting time to exit the setup menu 3 5 STATIC MODE The fixture has preprogrammed static looks that may be triggered without a controller W C CW Access these chases via the control panel on the back of the fixture To enable the static mode press MENU repeatedly until STATIC shows on the display Through the button UP DOWN select FIXT C Select the desired preset color R G B W GB RB RG RGB RW GW BW RGW RBW GBW RGBW through the buttons UP DOWN Press ENTER button to confirm Select the desired preset color using the button UP DOWN and press ENTER to confirm 3 6 MASTER SLAVE MODE This mode will allow you to link up the units together without a controller Choose a unit to function as the Master The unit must be the first unit in line other units will work as slave with the same effect e Press the button MENU so many times until the display shows M amp S and press the button ENTER Press UP DOWN to set the unit as master or slave MASTER or SLAVE Select on Master unit the desired program see section 3 4 Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units For longer cable runs we suggest a terminator at the last fixture see page 12 3 7 LINKING Several units may be interconnected in order to control all further slave units to the same effe
18. 000 051 GREEN 10 Dimmer mode off 052 101 0 100 000 255 Non linear dimmer 1 102 152 BLUE Non linear dimmer 2 153 203 4 0 100 000 255 Non linear dimmer 3 204 255 5 WHITE 0 100 000 255 COLOR MACRO No Function 000 010 chs R 100 G 0 100 B 0 011 030 R 100 0 G 100 B 0 031 050 o R 0 G 100 B 0 100 051 070 CH Function in Ch 5 mode Value R 0 G 100 0 B 100 071 090 MASTER DIMMER R 0 100 G 0 B 100 091 110 1 006 100 000 255 R 100 G 0 B 100 006 111 130 RED R 100 G 0 100 B 0 100 131 150 2 R 100 006 G 100 0 B 100 151 170 77 7 o R 100 6 10096 8 100 W 100 171 200 717 Color temperature 1 201 205 0 100 000 255 Color temperature 2 206 210 4 BLUE Color temperature 3 211 215 0 100 000 255 Color temperature 4 216 220 5 WHITE Color temperature 5 221 225 0 100 000 255 Color temperature 6 226 230 Color temperature 7 231 235 Color temperature 8 236 240 Color temperature 9 241 245 CH4 Color temperature 10 246 250 Color temperature 11 251 255 STROBE CH Function in Ch 4 mode Value 7 NoFunction 000 010 1 20Hz 011 255 1 FED AUTO 0 100 000 255 No Function 000 051 Q GREEN Show 1 Auto program 1 052 101 0 100 000 255 8 Show2 Auto program 2 102 152 3 BLUE Shovr 3 Auto program 3 153 203 0 100 000 255 Show 4 Auto program 4 204 254 4 WHITE Show 5 Auto program 5 255 0 100 000 255
19. BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE Music amp Lights S rl entertainment technologies Via Appia km 136 200 04020 Itri LT ITALY ISO 9001 2008 tel 39 0771 72190 fax 39 0771 721955 Certified Company vvvvvv musiclights it info musiclights it PROLIGHTS is a brand of Music 8 Lights S r l company 2013 Music amp Lights S r l PROLIGHTS un brand di propriet della Music 8 Lights S r l
20. OLIGHTS R User Manual PR SUPER SLIM LED PAR LUMIPAR18QPRO Manuale Utente 2 Music amp Lights S r l si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l uso La riproduzione anche parziale per propri scopi commerciali vietata AI fine di migliorare la qualit dei prodotti la Music amp Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it REV 004 09 13 LUMIPAR IBOPRO INDICE Contenuto dell imballo S icurezza Avvertenze generali Attenzioni e precauzioni per l installazione Informazioni generali 1 1 1 1 2 N 4 4 4 4 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Introduzione 1 Descrizione A 2 Specifiche tecniche 3 Elementi di comando e di collegamento Installazione 1 Montaggio Funzioni e impostazioni 1 Funzionamento 2 Impostazione base 3 Struttura menu 4 Modalita Auto Show 5 Modalit Static 6 Modalit Master Slave 7 Collegamento 8 Configurazione canale DMX 9 Modalit DMX 10 Collegamenti della linea DMX 11 Costruzione del terminatore DMX 12 Tabella canali DMX 13 Funzioni dispositivo 14 Informazioni sul dispositivo 15 Calibrazione bianco
21. ON The termination avoids the risk of DMX 512 signals being reflected back along the cable when they reach es the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination is prepared by soldering a 1200 1 4W resistor between pins 2 and 3 of the 3 pin male XLR connector as shown in figure 1200 Example 3 pin XLR connector Fig 7 LUMIPAR IBOPRO 13 3 12 DMX CONTROL CH10 CH Function in Ch 10 mode Value CH Function in Ch 10 mode Value 1 MASTER DIMMER 9 AUTO SPEED ADJUSTMENT 0 100 000 255 Slow Fast 000 255 2 RED DIMMER SPEED 0 100 000 255 Bulti in Dimmer 000 051 GREEN 10 Dimmer mode off 052 101 0 100 000 255 Non linear dimmer 1 102 152 BLUE Non linear dimmer 2 153 203 4 0 100 000 255 Non linear dimmer 3 204 255 5 WHITE 0 100 000 255 COLOR MACRO No Function 000 010 chs R 100 G 0 100 B 0 011 030 R 100 0 G 100 B 0 031 050 o R 0 G 100 B 0 100 051 070 CH Function in Ch 5 mode Value R 0 G 100 0 B 100 071 090 MASTER DIMMER R 0 100 G 0 B 100 091 110 1 006 100 000 255 R 100 G 0 B 100 006 111 130 RED R 100 G 0 100 B 0 100 131 150 2 R 100 006 G 100 0 B 100 151 170 77 7 o R 100 6 10096 8 100 W 100 171 200 717 Color temperature 1 201 205 0 100 000 255 Color
22. PAR18QPRO con un unit di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unit di comando previsto l indirizzo 33 per comandare la funzione del primo canale DMX si deve impostare sul LUMIPAR18QPRO l indirizzo di start 33 Le altre funzioni del pannello saranno assegnate automaticamente agli indirizzi successivi Numero Indirizzo di Indirizzo DMX Prossimo indirizzo di start Prossimo indirizzo di start Prossimo indirizzo di start canali DMX start esempio occupati possibile per unit n 1 possibile per unit n 2 possibile per unit n 3 10 33 33 42 43 53 63 DMX Address 33 DMX Address 43 DMX Address 53 DMX Address 63 Esempio di configurazione a 10 canali DMX modalit 10 Ch Fig 5 14 LUMIPAR IBOPRO 3 10 COLLEGAMENTI DELLA LINEA DMX La connessione DMX realizzata con connettori standard XLR Utilizzare cavi schermati 2 poli ritorti con impedenza 1200 e bassa capacit Per il collegamento fare riferimento allo schema di connessione riportato di seguito DMX INPUT DMX OUTPUT Spina XLR Presa XLR An Pin1 Massa Schermo Pin2 Negativo Pin3 Positivo Fig 6 ATTENZIONE La parte schermata del cavo calza non deve mai essere collegata alla terra dell impianto ci comporte rebbe malfunzionamenti delle unit e dei controller Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In t
23. TICO Durante gli interventi assicurarsi che l area sotto il luogo di installazione sia libera da personale non qualificato Spegnere l unit scollegare il cavo di alimentazione ed aspettare finch l unit non si sia raffreddata Tutte le viti utilizzate per l installazione dell unit e le sue parti devono essere assicurate saldamente e non devono essere corrose Alloggiamenti elementi di fissaggio e di installazione soffitto truss sospensioni devono essere total mente esenti da qualsiasi deformazione cavi di alimentazione devono essere in condizione impeccabile e devono essere sostituiti immediata mente nel momento in cui anche un piccolo problema viene rilevato Si dovrebbe procedere ad intervalli regolari alla pulizia della parte frontale per asportare polvere fumo e altre particelle Solo cos la luce pu essere irradiata con la luminosit massima Per la pulizia usare un panno morbido pulito e un detergente per vetri come si trovano in commercio Quindi asciu gare le parti delicatamente 4 2 SOSTITUZIONE FUSIBILE 1 Assicurarsi di scollegare il cavo di alimentazione del proiettore prima di sostituire un fusibile bruciato con uno dello stesso tipo 2 Con un cacciavite rimuovere il portafusibile dalla sua sede e il fusibile bruciato dal suo supporto sostituire il fusibile con uno identico per tipologia e valore 3 Inserire il portafusibile al suo posto e ricollegare l alimentazione EUSA Fig 8
24. al caso sconsigliato utilizzare nei collegamenti cavo bilanciato microfonico poich non in grado di trasmettere in modo affidabile i dati di controllo DMX e Collegare l uscita DMX del controller con l ingresso DMX della prima unit e Collegare quindi l uscita DMX con l ingresso DMX della successiva unit l uscita di quest ultima con l ingresso di quella successiva e via dicendo finch tutte le unit sono collegate formando una catena Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze consigliato inserire sull ulti ma unit una terminazione DMX 3 11 COSTRUZIONE DEL TERMINATORE DMX La terminazione evita la probabilit che il segnale DMX 512 una volta raggiunta la fine della linea stessa venga riflesso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della catena con connettori XLR a 3 pin saldando una resistenza di 1200 minimo 1 4W tra i terminali 2 e 3 cos come indicato in figura 1200 Esempio connettore XLR a 3 pin Fig 7 LUMIPAR IBOPRO 15 3 12 TABELLA CANALI DMX CH10 CH Function in Ch 10 mode Value CH Function in Ch 10 mode Value 1 MASTER DIMMER 9 AUTO SPEED ADJUSTMENT 0 100 000 255 Slow Fast 000 255 2 RED DIMMER SPEED 0 100 000 255 Bulti in Dimmer
25. are che frequenza e tensione della rete corrispondono alla frequenza ed alla tensione per cui l unit predisposta indicate sulla targhetta dei dati elettrici L unit non per uso domestico solo per uso professionale Evitare di utilizzare l unit in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiore ai 45 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al pi vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo E per lo smaltimento ad un istituzione locale per il riciclaggio Attenzioni e precauzioni per l installazione Se il dispositivo dovesse trovarsi ad operare in condizioni differenti da quelle descritte nel presente manuale potrebbero verificarsi dei danni in tal caso la garanzia verrebbe a decadere Inoltre ogni altra operazione potrebbe provocare cortocircuiti incendi scosse elettriche rotture etc Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull unit togliere la tensione dalla rete di alimentazione assolutamente necessario proteggere l unit per mezzo di una fune di sicurezza Nelleseguire qual siasi intervento attenersi scrupolosamente a tutte le normative in materia di sicurezza vigenti nel
26. are il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta del proiettore non possa supe rare i 20 cm Orientare il proiettore intervenendo se necessario sulla manopola della staffa di montaggio 2 LUMIPAR IBOPRO 9 3 FUNZIONI E IMPOSTAZIONI 3 1 FUNZIONAMENTO Per accendere il LUMIPAR18QPRO inserire la spina del cavo di alimentazione in una presa di rete 240V 50Hz L unit pu essere comandata da un unit DMX di comando luce oppure svolgere autonomamente il suo programma Per spegnere il LUMIPAR18QPRO staccare la spina dalla presa di rete Per maggiore comodit consigliabile collegare l unit con una presa comandata da un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore LUMIPAR18QPRO dispone di un LCD display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 0000 MENU UP DOWN ENTER s MENU UP DOWN ENTER Per scorrere il menu Per scorrere attraverso le Per scorrere attraverso le Per entrare nel menu selezionato principale o tornare ad 1 diverse funzioni in ordine diverse funzioni in ordine o confermare il valore attuale una opzione del menu discendente o aumentare il ascendente o diminuire il della funzione o l opzione precedente valore della funzione stessa valore della funzione stessa all interno di un menu 10 3 3 STRUTTURA MENU LUMIPAR IBOPRO
27. ct of the master unit 1 Connect the DMX OUT of the master unit via 3 pole XLR cable to the DMX IN of the first slave unit 2 Connect the DMX OUT of the first slave unit to the DMX IN of the second slave unit etc until all units are connected in a chain LUMIPAR IBOPRO 11 3 8 DMX CONFIGURATION LUMIPAR18QPRO is equipped with different DMX configuration Press the button MENU so many times until shows CHANNEL and press the button ENTER to confirm Select the desired DMX configuration 4CH 5CH 10CH through the buttons UP DOWN The tables on page 13 indicate the operating mode and DMX value The LUMIPAR18QPRO is equipped with 3 pole XLR connections 3 9 DMX MODE Press the button MENU so many times until the display shows ADDRESS and press the button ENTER to confirm Press UP DOWN button to select the desired value 001 512 Press and hold to scroll quickly Press ENTER button to store Press the MENU button to go back or to meet the waiting time to exit the setup menu To able to operate the LUMIPAR18QPRO with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust the start address 33 on the LUMIPAR18QPRO The other functions of the light effect panel are then automatically assigned to the follovving addresses An example with the start address 33 is shown below
28. e sold ex works and always travel at the risk and danger of the distributor Eventual dam age will have to be claimed to the freight forwarder Any claim for broken packs will have to be forwarded within 8 days from the reception of the goods Warranty and returns The guarantee covers the fixture in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the va lidity of the guarantee is endorsed solely on presentation of the guarantee certificate Music amp Lights will verify the validity of the claim through examination of the defect in relation to proper use and the actual validity of the guarantee Music amp Lights will eventually provide replacement or repair of the products de clining however any obligation of compensation for direct or indirect damage resulting from faultiness 4 LUMIPAR IBOPRO 1 INTRODUCTION 1 1 DESCRIPTION LUMIPAR18QPRO is a super slim ParLED for professional use designed to be a powerful wash light in Rental Touring applications It s equipped with 18 x 8W high efficiency RGBW FC LEDs light source conceived to offer an advanced color generation with full control on color saturation
29. eAowad pue saYIMMS s lpueu sdwe syed jeusayxq u uldinb 24 JO ua WI 29E dal BY 104 UOIsIAOJd OU sayewi aazuesenb y u q sey juawidinba y JI AP H aq s 5uo Ou im aaqjuerenb y p pni x aie juawdinba y Jo Huljpuey 393J ODUI pue Aq pasned si q aajuesenb Ino uo a gejiene w104 v B lp s pue ul 6ui jy pasaysi6au Osje aq ued ay 1 S1YBI PISNU MMM uo Sul55o y aseydind noZ Jaye uoos juawdinba adaid y s si5 i o JAQUIRWISI SP Ll SUOI IPUOD Bd URIEND les u np pensqy 1 s3YBIPISNU MMM 5 Q M Ano UO suon puo aajURJeND E4 U D Y JO UOISISA ln dy puy uv no suonejnbaa bunsix u ucllduio ul yun v 5 aazuesenb ay pizuDIDb IP Jap auolzbjJuasaid a uaw balun vIZUDIDB b l p aya WE mny 0142234Dddb jap 210ssassod l p 0214092 b OUOS HuanbasuoI q su 1 o ylodsou ip s ds lqouodsp HONNI 1 6 ajodounw ausajsa Ibd aj DIZUDIDO snl s 014223 Dddb jjap uolzn nsos b apanad pIZUDIDO o7 OSSA 01018 DIS 01Y2934Dddb 0 9ya nid pu uou DIZUDIDB DT osn pp pizM dull pp nosno nsp
30. ial use In order to improve the quality of products Music amp Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it LUMIPAR IBOPRO TABLE OF CONTENTS Packing content Safety General instructions Warnings and installation precautions General information Introduction 1 Description VERITA 2 Technical specifications 3 Operating elements and connections oa add 2 Installation 1 Mounting N Functions and settings 1 Operation 2 Basic 3 Menu structure 4 Auto Show mode 5 Static mode 6 Master Slave mode 7 Linking k 8 DMX configuration 9 DMX mode a 10 Connection of the DMX line 11 Construction of the DMX termination 12 DMX control 13 Fixture settings 14 Fixure information 15 White calibration w w w LI LI LI LI WI W Li Li WI W W w v 4 Maintenance 4 1 Maintenance and cleaning the unit 4 2 Fuse replacement 4 3 Trouble shooting Warranty e LUMIPAR18QPRO Mount bracket 2pc e Power cable User manual N 10 10 10 10 11 11 12 12 13 14 14 15 16 16 16 2 LUMIPAR IBOPRO WARNING Before carrying out any operations with the unit carefully read this instruction A manual and keep it with cure for future reference It contains important information about A the insta
31. ionamento del dispositivo Premere il tasto MENU ripetutamente fino a quando sul display non compare INFO Premere ENTER per confermare Selezionare attraverso i tasti UP DOWN FIXHOURS quindi premere ENTER per confermare Il display indicher le ore di funzionamento Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di im postazione Version Permette di visualizzare la versione firmware del proiettore Premere il tasto MENU ripetutamente fino a quando sul display non compare INFO Premere ENTER per confermare Selezionare con i tasti UP DOWN la funzione VERSION e premere ENTER e Il display indicher la versione firmware del proiettore Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di im postazione LUMIPAR IBOPRO 17 3 15 CALIBRAZIONE BIANCO Per impostare il bilanciamento del bianco intervenendo sui parametri R G e B Premere il tasto MENU fino a quando sul display non appare WHITE BALANCE quindi premere il tasto ENTER Selezionare il canale R G e B attraverso i tasti UP DOWN Per confermare premere il tasto ENTER Impostare i valori 125 255 attraverso i tasti UP DOWN quindi premere il tasto ENTER Premere il tasto MENU per tornare indietro o attendere alcuni secondi per uscire dal menu di impostazione 18 4 MANUTENZIONE 4 1 MANUTENZIONE E PULIZ LUMIPAR IBOPRO IA DEL SISTEMA OT
32. llation usage and maintenance of the unit SAFETY General instruction The products referred to in this manual conform to the European Community Directives and are there fore marked with ce The unit is supplied with hazardous network voltage 230V Leave servicing to skilled personnel only Never make any modifications on the unit not described in this instruction manual otherwise you will risk an electric shock Connection must be made to a power supply system fitted with efficient earthing Class appliance ac cording to standard EN 60598 1 It is moreover recommended to protect the supply lines of the units from indirect contact and or shorting to earth by using appropriately sized residual current devices The connection to the main network of electric distribution must be carried out by a qualified electrical installer Check that the main frequency and voltage correspond to those for which the unit is designed as given on the electrical data label This unit is not for home use only professional applications Never use the fixture under the following conditions in places subject to vibrations or bumps in places with a temperature of over 45 C Make certain that no inflammable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer direct
33. ly If the unit is to be put out of operation definitively take it to a local recycling E plant for a disposal which is not harmful to the environment VVarnings and installation precautions If this device will be operated in any way different to the one described in this manual it may suffer damage and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc Before starting any maintenance work or cleaning the projector cut off power from the main supply Always additionally secure the projector with the safety rope When carrying out any work always com ply scrupulously with all the regulations particularly regarding safety currently in force in the country in which the fixture s being used Install the fixture in a well ventilated place Keep any inflammable material at a safe distance from the fixture Shields lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired The lamp LED shall be changed if it has become damaged or thermally deformed Never look directly at the light beam Please note that fast changes in lighting e g flashing light may trigger epileptic seizures in photosensitive persons or persons with epilepsy Do not touch the products housing when operating because it may be very hot LUMIPAR IBOPRO 3 GENERAL INFORMATION Shipments and claims The goods ar
34. n6 isni s 04394 NS 030 4OdL JI opubinui opubjiduio3 0301351631 asassa ond DAIJDUJA D l 4 s1Y6i gt isnu mmm 0115 15 Jap 120115 1 p 201d Ip orsinbab odop obaid i DIZUDADY Ip I D1aUaD IUOIZIPUOD 0115414 DIZUDADD Ip I DAaUaD ll p 0 Sa 15 2 ajiqissod a sp ybijpisnu mmm 15 ins AHDUuMoOU guabia liD sbq ul pIZUDAD opopoid MODEL MODELLO SERIAL N SERIE N a wy Purchased by Acquistato da SURNAME COGNOME NAME NOME ADDRESS VIA N 4 5 CITY CITTA ZIP CODE C A P PROV Dealer s stamp and signature Timbro efirma del Rivenditore Purchasing date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE MODEL MODELLO SERIAL N SERIE N 7 ng Purchased by Acquistato da SURNAME COGNOME NAME NOME 4 ADDRESS VIA CITY CITT s ku ez 4 ZIP CODE C A P Dealer s stamp and signature Timbro e firma del Rivenditore PROV V Purchasing date Data acquisto FORM TO
35. nstallation always comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm Adjust the projector and use the knob 2 to slightly release or tighten the locking mechanism of the bracket if is necessary LUMIPAR IBOPRO 3 FUNCTIONS AND SETTINGS 3 1 OPERATION Connect the supplied main cable to a socket 100 240 VAC 50 60 Hz Then the unit is ready for operation and can be operated via a DMX controller or it independently performs its show program in succession To switch off disconnect the mains plug from the socket For a more convenient operation it is recom mended to connect the unit to a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LCD Display fig 3 O O O O MENU UP DOWN ENTER Fig 3 MENU ENTER Used to select and store the current menu or confirm the current function value or option within a menu Used to access the menu or to return a previous menu option UP Navigates downwards th
36. plificato 4canali RGBW 5 canali Dimmer RGBW 10 canali Dimmer RGBW strobe macro auto auto speed dimmer curve Regolazione curva dimmer 3 configurazioni selezionabili Modalit Automatica programmi automatici preimpostati con regolazione velocit Modalit colori statici riproduzione statica di un colore Modalit Master Slave per il controllo di pi unit collegate in catena Passaggio lineare stepless dei valori sui canali DMX Frequenza dei diodi anti flicker 400Hz per videoriprese Corpo e alimentazione e Corpo in alluminio pressofuso grado di protezione IP54 Silenziosit di funzionamento proiettore privo di ventole e struttura disegnata per avere una dissipa zione a convezione naturale Doppia staffa per il fissaggio in sospensione o il posizionamento da terra Alimentazione 100 240V 50 60Hz Cablaggio IN OUT alimentazione e segnale attraverso connessioni XLR3p Powercon Assorbimento medio 125W output fino a 8 proiettori Peso 5kg e Dimensioni LxAxP 302x239x259mm LUMIPAR IBOPRO DMX IN oo 1 3 ELEMENTI DI COMANDO EDI COLLEGAMENTO MENU UP DOWN ENTER ooooooooooooooo 00000000000000000 ooooooooooooooooo o oo o sa ooo ooo 2 o boood 0000 DMX OUT oo 000 R000 S oe 1 oo SAFETY ROPE o 000000 089000 080000 POWER IN 100 240V AC 50 60 2 POVVER
37. rough the menu list and increases the numeric value when in a function DOWN Navigates upwards through the menu list and decreases the numeric value when in a function 3 3 MENU STRUCTURE LUMIPAR IBOPRO MENU LEVEL 1 LEVEL 2 LEVEL 3 REMARK 1 Auto Auto Speed 5 Automatic programs lt Auto1 gt lt Auto1 gt lt 100 gt lt Auto2 gt lt 100 gt lt Auto3 gt lt 100 gt lt Auto4 gt lt 100 gt lt Auto5 gt lt 100 gt 2 Static Static Fix C lt FixC gt lt R Red gt Green lt B gt Blue lt W gt White lt GB gt Green Blue lt R B gt Red Blue lt RG Red Green lt RGB gt Red Green Blue W gt Red White lt G W gt Green White x BW gt Blue White lt RG W gt Red Green White lt R BW gt Red Blue White lt GBW gt Green Blue White lt RGBW gt Red Green Blue White lt Manu C gt Manual C lt R 255 gt lt 62555 Combine red green blue and white to make a custom color lt B 255 gt lt W 255 gt 3 Dim Mode Dim Mode lt DIM1 gt lt Off gt Default On lt DIM1 gt DIM 1 Dimmer speed fast 0 8 s lt DIM2 gt DIM 2 Dimmer speed middle 1 6 s lt DIM3 gt DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite lt 0n gt lt n gt Default On lt 10s gt 10 s Off after 10 seconds lt 205 gt 20 s Off after 20 seconds lt 305 gt 30 s Off after 30 seconds 5 Info Auto Auto Test Test LUMIPAR IBOPRO
38. rte condizioni e lunghezze si consiglia di effettuare una terminazione come mostrato a pagina 14 3 7 COLLEGAMENTO Si possono collegare pi unit affinch tutte le unit secondarie abbiano lo stesso effetto luce dell unit principale Master 1 Collegare l uscita DMX OUT dell unit principale con l ingresso DMX IN della prima unit secondaria servendosi di un cavo XLR a 3 poli 2 Collegare l uscita DMX OUT della prima unit secondaria con l ingresso DMX IN della seconda unit secondaria ecc LUMIPAR IBOPRO 13 3 8 CONFIGURAZIONE CANALI DMX Il LUMIPAR18QPRO dispone di diverse configurazioni dei canali DMX a cui si pu accedere dal pannello di controllo Premere il tasto MENU fino a quando sul display non appare CHANNEL quindi premere il tasto ENTER Attraverso i tasti UP DOWN selezionare la configurazione dei canali DMX che si desidera 4CH 5CH 10CH Premere il tasto ENTER per confermare Le tabelle a pagina 15 indicano le modalit di funzionamento e i relativi valori DMX Come interfaccia DMX l unit possiede dei contatti XLR a 3 poli 3 9 MODALIT DMX Per impostare l indirizzo DMX premere il tasto MENU fino a quando sul display non appare ADDRESS quindi premere il tasto ENTER Premere il tasto UP DOWN per selezionare il valore desiderato 001 512 tenere premuto invece il tasto UP DOWN per lo scorrimento veloce Premere il tasto ENTER per confermare l impostazione Per poter comandare il LUMI
39. temperature 2 206 210 4 BLUE Color temperature 3 211 215 0 100 000 255 Color temperature 4 216 220 5 WHITE Color temperature 5 221 225 0 100 000 255 Color temperature 6 226 230 Color temperature 7 231 235 Color temperature 8 236 240 Color temperature 9 241 245 CH4 Color temperature 10 246 250 Color temperature 11 251 255 STROBE CH Function in Ch 4 mode Value 7 NoFunction 000 010 1 20Hz 011 255 1 FED AUTO 0 100 000 255 No Function 000 051 Q GREEN Show 1 Auto program 1 052 101 0 100 000 255 8 Show2 Auto program 2 102 152 3 BLUE Shovr 3 Auto program 3 153 203 0 100 000 255 Show 4 Auto program 4 204 254 4 WHITE Show 5 Auto program 5 255 0 100 000 255 14 LUMIPAR IBOPRO 3 13 FIXTURE SETTINGS It is possible to change the parameter value in the following way Dimmer Enter in Dimmer mode to select specific dimming curve press the button MENU so many times until shows DIM MODE and press the button ENTER to confirm Press the button UP DOWN to select Off DIM1 DIM2 DIM3 Press ENTER button to store Press the MENU button to go back or to meet the waiting time to exit the setup menu BackLite e To activate Backlight display press the button MENU so many times until shows BACKLITE and press the button ENTER to confirm Press the button UP DOWN to select On 10S 205 30S Press ENTER button to confirm the selection Press
Download Pdf Manuals
Related Search
Related Contents
Libros Mágicos (Niños) – Descargar PDF Jasco 98046 User's Manual 1 - BroadcastStore.com FS 1000 BELZONA 3131 Fiche Technique Opening - LinkStation Web Access 極性確認用ペグ取扱説明書 Radio Shack 580 Electronic Keyboard User Manual Samsung 32" LED TV F6105 Bruksanvisning König KN-URC10B remote control Copyright © All rights reserved.