1. Refering to the Polar unit and probes used execute the connections marked on DIS 4434 DGA310 DIS 4435 DGA300 DGA302 DIS 4436 DGA304 Attention drawing shows connection type with heater version sensors if the heater system is not available do not connect the reference wires Important Only for DGA302 and DGA304 instrument is factory setup to receive signals from sensors with 0 20 MA output If the connected sensor is 4 20 mA output operate as describe in 6 Change mA outputs inputs When the DGA304 units is connected to the DNA521 CombiSD wind speed and direction sensor the connection is the following Black wire input n 16 Blue wire input n 14 short circuit between inputs 14 amp 11 Red wire input n 13 Brown wire 12 Vdc from external source White wire 0 Vdc from external source D When kompass or tachimeter systems are not used remind to leave in overcircuits the terminals 17 18 and 19 20 When connected kompass or tachimeter systems with 0 4 20 mA output remove the overcircuits and connect on each couple a 100 Ohm accuracy 0 1 resistance unit The resistance unit is not needed if used kompass and tachimeter systems with 0 0 4 2V output Close the protection panel 3 4 A B The Polar Anemometer is delivered by LASTEM set for the processing of 2 mean values although the time base may be change to 10 The 10 time base is set as follows Turn off the
2. 190 5 SCHERMO SHIELD B BIRNCO UHITE GIRLLO TELLDU 2 NERO ELRCK 5 BLU BLLIE 1 HARR NE BROVN 4 R0550 RED UTENZE ESTERNE EXTERNAL SERVICE O7 4 20MmA VELOCITA MEDIR RUERRGE SPEED Z GIRLLD YELL OL L DIREZ PRELALENTE PREURILIMNG DIRECTION 5 BIRHCD UHITE III I CAVOZCABLE DWUASXX DGA 318 Alimentazione Power supply Descrizione della revisione sim revisione Scala Codice Disegno m LABORATORI DI E 4434 STRUMENTAZI OHE cass vizio INDUSTRIALE S p CENTRALINA EDLICA POLARE 1 STHENA DI ENRERE EOLICO COMBINATO POLAR CEPIBB INTERCIHHECTIOH DIAGRAM VETH COMBIHED SPEED AHD DIPECTIOH SERSIR Manuale Anemometro Polare 7 10 Polar unit user s manual INGRESSO BUSSOLA CONPASS INPUT 8 4 2U Sb8 DGASABI CEP 100 re ua a DIREZIONE DIRECTION CT SISMI MITE UTENZE ESTERNE EXTERNAL SERVICE B 4 28mA VEL MEDIASAVERAGE SPEED DIR PREVALENTE PREVAILING DIRECTION DNABSZ C1619 E DGA 300 Xii a UELOCITR SPEED mma EEI HITE Alimentazione Power supply Uca ASSENZA DELLA BUSSOLA CORTOCIROJITARE I MORSETTI 17 16 WITHOUT CONPASS CONNECTION TD SHORT CIRCUIT TERMINALS 17 18 ASSENZA DEL TACHINETRO CORTOCIRCUITARE I MORSETTI 19 20 WITHOUT TACHOMETER CONNECTION TO SHORT CIRCUIT TERMINALI 19 20 Alimen
3. pannello Collegamento elettrico dei fili 1 Rimuovere il pannello posteriore di protezione 2 Inserire attraverso i passacavi del pannello di protezione i cavi dei sensori dei convertitori dell alimentazione e quelli eventuali dei trasmettitori di direzione e velocit assolute 3 A seconda del modello del sensore e Anemometro Polare scelto eseguire i collegamenti descritti nei disegni DIS 4434 DGA310 DIS 4435 DGA300 DGA302 DIS 4436 DGA304 Attenzione i disegni riportano il collegamento a versioni riscaldate di sensori se il sensore in possesso non riscaldato non collegare i fili del riscaldamento Importante Solo per DGA302 e DGA304 lo strumento programmato in fabbrica per accettare sensori con uscita 0 20 MA se il sensore connesso ha uscita 4 20 mA operare come da 6 Cambio del segnale ingresso uscita in mA Quando il DGA304 connesso ad un sensore tipo CombiSD DNA521 esso deve essere connesso come Segue Filo nero ingresso n 16 Filo blu ingresso n 14 cortocircuitare ingressi 14 amp 11 Filo rosso ingresso n 13 Filo marrone 12 Vdc da alimentazione esterna Filo bianco 0 Vdc da alimentazione esterna C Quandoil tachimetro e la bussola non vengono utilizzati rammentarsi di lasciare cortocircuitate le coppie di morsetti 17 18 e 19 20 Quando sono connessi solcometro e bussola con uscita in mA 0 4 20 mA rimuovere il cortocircuito sui morsetti 17 18 e 19 20
4. CARATTERISTICHE TECNICHE 3 TECHNICAL SPECIFICATIONS COD IN 1 2 IN 3 IN 4 Sensori Sensors Sensori Sensors Bussola Kompas Tachimetro Tach Velocit speed Direz Direct 0 359 9 0 50 DNA001 DNA002 DNA010 DNA011 0 0 4 2V 0 0 4 2V 0 4 20MA 0 4 20MA DGA302 DNA001 DNA002 DNA010 DNA011 0 0 4 2V 0 0 4 2V X120SD 9 6 imp m X120SD 0 4 20MA 0 4 20MA 0 4 20MA DGA304 DNA501 DNA502 DNA510 DNA511 DNA505 DNA506 DNA514 DNA515 DGA310 DNA521 DNA527 0 0 4 2V 0 0 4 2V 0 4 20MA 0 4 20 COD OUTPUT 1 OUTPUT 2 Vel Media Ave speed Dir Prev su 36 settori Prevalent direction over 36 sectors DGA300 0 4 20 0 4 20 0 50 m s 2 0 4 20 0 4 20 0 50 m s DGA304 0 4 20 0 4 20 0 60 m s 10 0 4 20 0 4 20 0 60 m s Caratteristiche Features Campo misura direzione Wind direction range Campo misura velocit 0 50 0 m s Ris 0 1 m s Wind speed range Tolleranza Trascurabile rispetto ai sensori Negligible for sensors Accurac Limiti ambientali Environmental limits Alimentazione Power suppl Uscita direzione prevalente 0 4 20 MA ris 1 Prevalent wind direction selezionabile selectable su over 2 or 10 output Uscita velocit media 0 4 20mA ris 0 1 m s Wind speed output selezionabile selectable su over 2 or 10 Diagnostica Verifica del funz
5. IERA 0 IHTERCA Manuale Anemometro Polare 9 10 Polar unit user s manual Manuale Anemometro Polare 10 10 Polar unit user s manual
6. LASTEM LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it MW6205 Rev b ANEMOMETRO POLARE POLAR ANEMOMETER Manuale utente User s manual dd 04 yy L NDOC MANUALI APPARECCUTALIA MW6205 3 TECHNICAL SPECIFICATIONS 4 INSTRUMENT ASSEMBLING 5 CHANGE OF TIME BASE FOR MEAN DI CALCOLO DELLE MEDIE TIMES CALCULATION USCITA IN mA STRUMENTO COD DGA310 DIS 4434 COD DGA310 DRW 4434 SCHEMA DI CONNESSIONE CONNECTION DRAWING STRUMENTI COD DGA300 DGA302 INSTRUMENTS COD DGA300 DGA302 DIS 4435 DRW 4435 SCHEMA DI CONNESSIONE CONNECTION DRAWING INSTRUMENT STRUMENTO COD DGA304 DIS 4436 COD DGA304 DRW 4436 DISPOSIZIONE COMPONENTI SCHEDA COMPONENTS ON CPU BOARD CPU DIS BS1518RA DRW BS1518RA ASSEMBLAGGIO VISTA D ASSIEME LATERAL VIEW ASSEMBLING Manuale Anemometro Polare 1 10 Polar unit user s manual LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it 1 INTRODUZIONE 1 INTRODUCTION L Anemometro Polare CEP uno strumento a microcalcolatore atto a fornire dettagliate informazioni di situazioni anemologiche anche complesse Esso calcola ed indica velocit media scorrevole velocit istantanea velocit massima direzione prevalente direzione istantanea dispersione delle d
7. contenimento Individuare la scheda CPU CS1517 ved disegno n BO1691 Sulla scheda CPU CS1517 commutare la sezione 1 del dipswich contrassegnato sul disegno n BS1518RA dalla sigla SW2 ON 4 20 mA OFF 0 20 mA Rimontare lo strumento Manuale Anemometro Polare 6 10 On DGA300 and DGA310 signal output is selectable 0 20 mA or 4 20 mA On DGA302 and DGA304 signal output must be the same as the signal output from the connected sensors Polar Anemometer is factory setup with 0 20 mA output in case of change operate as follow Turn off the main power supply from instrument Remove the panel protecting the terminals Unscrew and take down the terminals panel Remove the instrument core from the box Find printed circuit board CPU CS1517 see dwg BO1691 On card CPU CS1517 change the dip1of dipswitch SW2 showed on the dwg n BS1518RA ON 4 20 mA OFF 0 20 mA Reassemble as before Polar unit user s manual ASSENZA DELLA BUSSOLA CORTOCIRCUITARE I MORSETTI 17 18 WITHOUT COMPASS CONNECTION TO SHORT CIRCUIT TERMINALS 17 1 XX IN ASSENZA DEL TACHINETRO CORTOCIRCUITARE I MORSETTI 19 26 WITHOUT TACHOMETER CONNECTION TO SHORT CIRCUIT TERMINALS 19 2 COD DNAG21 22 INGRESSO BUSSOLA B H 4 2U 6 4 2006 3569 ConPASS 4 20 8 4 28mRh S660 INGRESSO TACHIMETRO 8 8 4 2U 5Bkn I TRCHOHETER INPUT 6 6 4 2UISG6kNI DGASIBICEP
8. e inserire una resistenza da 100 Ohm accuratezza 0 1 Questa resistenza non occorre quando si utilizzano solcometri e bussole con uscite in tensione 0 0 4 2 V Chiudere il pannello di protezione B L Anemometro Polare programmato dalla fabbrica con l elaborazione delle medie su 2 Tale base pu essere variata su 10 operando come segue 1 Togliere l alimentazione allo strumento 2 Rimuovere il pannello posteriore di protezione dei morsetti 3 Svitare le quattro viti esagonali del pannello morsetti e togliere tale pannello 4 Sfilare l anima dello strumento dalla scatola di contenimento 5 Individuare la scheda CPU CS1517 ved disegno1691 6 Sulla scheda CPU CS1517 commutare la sezione 2 del dipswich contrassegnato sul disegno n BS1518RA dalla sigla SW2 ON 25 OFF 10 Wind sensors installation see MW6010 user s manual The Polar Anemometer is may be installed either on a surface or fitted to a panel For the table model attach the feet to the instrument base Proceed as follows for the panel mount variant 1 Fit the instrument to the panel after first making a hole to 282 x 186 mm template 2 Fit the tie rods in the slots in the sides of the instrument 3 Sore down the tie rod screws until they make contact with the panel Wire connection 1 Remove the rear protection panel 2 Introduce the leads from sensors or converters and the power leads troughs the bushings in the protection panel
9. instrument 2 Remove the panel protecting the terminals 1 Unscrew and take down the terminals panel 2 Remove the instrument core from the box 5 Find printed circuit board CPU CS1517 see dwg 1691 3 CPU CS1517 change the dip2 of dipswitch SW2 showed on the dwg n BS1518RA ON 25 OFF 10 Reassemble as before N Manuale Anemometro Polare 410 Polar unit user s manual LASTEM LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it 7 Rimontare lo strumento Manuale Anemometro Polare 5 10 Polar unit user s manual LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it 6 CAMBIO DEL SEGNALE INGRESSO USCITA IN mA 6 CHANGE mA INPUTS OUTPUTS Per i cod DGA300 e DGA310 il segnale di uscita selezionabile 0 20 mA o 4 20 mA Per i cod DGA302 e DGA304 il segnale di uscita dallo strumento deve essere uguale al tipo di segnale di uscita dei sensori ad esso collegati Lo strumento programmato in fabbrica per sensori uscita 0 20 mA Operare come segue per modificare l impostazione Togliere l alimentazione allo strumento Rimuovere il pannello posteriore di protezione dei morsetti Svitare le quattro viti esagonali del pannello morsetti e togliere tale pannello Sfilare l anima dello strumento dalla scatola di
10. ionamento degli indicatori per mezzo della Diagnostics loro completa accensione nei primi secondi di funzionamento dello strumento When the instrument is switched on all the light indicators are lit simutaneosly Comandi 1 Commutatore per selezionare Vel Ist Vel Max Controls 2 Commutatore per selezionare le unit di misura m s km h kn 1 Switch for selecting vel max vel inst 2 Switch for selecting units m s km h kn Ingressi per il computo del Velocit speed 0 4 20 mA 0 50 kn Inputs for true wind vento vero su mezzi mobili Direzione direction 0 4 20 mA 0 359 measurement not available non disponibile su DGA304 on DGA304 Manuale Anemometro Polare 3 10 Polar unit user s manual LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it 4 INSTALLAZIONE STRUMENTO 4 INSTRUMENT ASSEMBLING Istallazione sensori anemometrici ved Manuale MW6010 L Anemometro Polare pu essere installato sopra un ripiano oppure inserito in un pannello quadro Per l esecuzione da tavolo inserire gli appositi piedini sulla base dello strumento Per l esecuzione da pannello procedere come segue 1 Inserire lo strumento nel pannello forature con dima 282x186 2 Inserire i tiranti nelle apposite fessure poste sui lati dello strumento 3 Avvitare le viti dei tiranti fino a che esse non vadano in battuta sul
11. irezioni istantanee velocit della raffica pi forte Le velocit sono leggibili sui due visualizzatori sulla destra del pannello vel med Velocit media scorrevole negli ultimi 2 o 10 minuti Velocit istantanea ovvero dell ultima acquisizione Velocit della raffica pi forte negli ultimi 2 o 10 minuti vel ist vel max Le direzioni sono leggibili in forma polare in gradi e in punti cardinali Sulla corona esterna indicata la direzione prevalente scorrevole su 2 o 10 cio la direzione in cui il gonioanemometro stato letto pi volte negli ultimi 2 10 Il computo scorrevole cio l ingresso di un dato nuovo provoca l abbandono del dato pi vecchio Sulla corona interna indicata ad elevata luminosit la direzione istantanea a bassa luminosit sono indicate le ultime 10 letture del sensore di direzione corrispondenti alla dispersione della direzione istantanea La condizione di Calma dichiarata per velocit inferiori a 0 3 m s che perdurino pi di 2 o 10 Le due corone si spengono mentre si accende un indicatore verde al centro di tali corone L Anemometro Polare installato su mezzi mobili anche in grado di fornire i dati del vento vero in funzione del vento apparente correggendo le letture eseguite dai sensori anemometrici con i dati di velocit e direzione del veicolo su cui sono montati A questo scopo necessario far pervenire agli appositi m
12. mber of goniometer readings has been obtained during the last 2 or 10 It is shifting in type that is the input of a new datum causes the older datum to be abandoned The instantaneous direction reading is given on the inner corona by the brightest led whereas the other dimmer led s indicate the last 10 acquisitions thereby supplying the dispersion of instantaneous directions Calm for velocities below 0 3 m s of more than 2 or 10 duration the led s in the two coronas are cut out and a green led at the centre of the coronas is lit When the Polar Anemometer CEP is installed on mobile vehicles it can measure the true wind against the wind direction This reading is calculated using informations from an electronic compass connected to the CEP unit 2 MODELS DGA300Polar Anemometer used with cod DNA001 DNA002 wind speed and cod DNA010 DNA011 wind direction DGA302Polar Anemometer used with cod DNA001 DNA002 wind speed and cod DNA010 DNA011 wind direction using the X120SD converter as interface DGA304 Polar Anemometer with CombiSD sensor cod DNA521 o DNA522 with analogue outputs 0 4 20 mA This model do not accept signals from kompass and tachimeter systems DGA310Polar Anemometer used with CombiSD sensor cod DNA021 o DNA022 Polar unit user s manual LASTEM Srl Loc Dosso 20090 Settala MI Italy Fax 39 0 2 95770594 E Mail info lsi lastem it INTERNET URL http www Isi lastem it 3
13. orsetti del CEP i segnali provenienti dalla bussola dal tachimetro solcometro 2 MODELLI DGA300 Anemometro Polare per collegamento a sensori cod DNA001 DNA002 vel vento e cod DNA010 DNA011 dir Vento DGA302 Anemometro Polare per collegamento a sensori cod DNA001 DNA002 vel vento e cod DNA010 DNA011 dir Vento interfacciati a convertitore X120SD DGA304 Anemometro Polare per collegamento a sensore combinato cod DNA521 o DNA522 con segnale 0 4 20 mA Questo modello non accetta segnali da bussole e tachimetri DGA310 Anemometro Polare per collegamento a sensore combinato vel dir vento cod DNA021 o DNA022 Manuale Anemometro Polare 2 10 The Polar Anemometer CEP measures wind velocity and direction giving the readings of Speed running average Instantaneous speed Maximum speed Prevalent direction Instantaneous direction Spread of the last directions values Strongest gust speed reading The speed wind values are read on the two displays on the write side of the unit vel med Running average speed on the last 2 or 10 vel ist Instantaneous speed vel max Indicates the strongest gust in the last 2 or 10 The direction may be read in polar form on the led s coronas These directions are displayed as degrees and cardinal points The prevalent direction of flow over 2 or 10 is shown on the external corona that is the direction for which the greater nu
14. tazione Power supply IHGRESSO BUSSOLA COMPABI IHPUT 1 4 20 36 HGEEZSU TECHINETEDAISCHONETER INF 5 4 DGa382 CEP 182 DNAB11 C101D UTENZE ESTERNE EXTERNAL SERVICE 0 4 2BmA UEL MEDIR RUERRGE SPEED DIR PREUGLEHTE PREURILING DIRECTION DIREZIONE DIRECTION DNABB2 C1015 VELOCITR SPEED Uca Drigina Descrizione della revlalore Esp dl 18 rexit Li WLABORATORI DI Desoriz INDUSTRIALE S P CORALLI Manuale Anemometro Polare 8 10 Polar unit user s manual DG5R38A4 l CEP 2B1 DIREZIONE DIRECTION 4 260 RU LUE 44 20mA MERD BLECK UTENZE ESTERNE EXTERNAL SERUICI DIREZ PREVALENTE PREVAILING DIRECTION DNASO2 C5015 VELOCIT 5 ms DGA 384 Alimentazione Power supply Uca DGASHMA CEP 201 ERICH DNAB11 C181D 4 GIALLOMELLOY 4 GIALLOMELLOY 4 5 BIeHCD uHITE UTENZE ESTERME EXTERNAL SERUICE 6 4 20mA VELDONTA MEDI AVERAGE SPEED DIREZIOHE DIRECTION DIREZ PREMRLEHTE PREURILIHG DIRECTION DNAGGOZ C1015 4 BIALLIVVELLIV de VELOCITA SPEED DGA 384 Alimentazione Power supply Uca DSC aram ec va ECZEEN ETME T ex Soslar cu Disegni FE E Tiss 1 Tamcrizione INIUETRIALE B p Ri CENTRALINI EOLICA BC