Home

Operating Manual

image

Contents

1. Block the exhaust flow on the mask e Use the mask if the unit is turned off or not operating properly Use an insulating sleeve or any similar accessories which are not approved by Fisher amp Paykel Healthcare These may affect the humidification performance e Try to remove the heated breathing tube without pushing the sleeve up first This will avoid damage to the connection port To avoid burns do not e Fill the chamber with boiling water e Touch the exposed heater plate or chamber base e Position the breathing tube in such a way that it can come into prolonged contact with skin To avoid the risk of fire while using oxygen do not e Turn oxygen flow on when the device is not operating this can lead to accumulation of oxygen within the device e Locate the device in a position where ventilation around the device is restricted e Use oxygen while smoking or in the presence of an open flame e Use any materials which will burn in air or ignite easily at high oxygen concentration e Keep any source of ignition near the product To avoid ignition it is preferable to keep all sources of ignition out ofthe room where supplemental oxygen is being used Keep oxygen regulators cylinder valves tubing connections and all other oxygen equipment near oil grease or greasy substances Spontaneous and violent ignition may occur if these substances come into contact with oxygen under pressure Operate the device without the c
2. ON Reduces pressure to a lower level o Press 1 to help you fall asleep The pressure NB to reset ramp during a cycle the device must be switched off first will gradually return to full operating pressure over 20 minutes TO SWITCH OFF Press INCREASE DECREASE Adjusts settings up or down e Press A and V button to raise or lower settings MODE To step through options e Press sequentially to step through and view options available PATIENT MENU DISPLAY OPERATION For viewing CPAP settings humidity TO VIEW ITEMS compliance data altitude and pressure Press P gt key to sequentially view u e ThermoSmart Humidity setting default display For adjusting ThermoSmart Humidity setting levels to minimize upper airway side effects from CPAP use Press A and V button to raise or lower settings e Total run hours displays the total number of hours the device has been switched on includes hours without mask use e Average compliance hours per night displays average number of hours the device has been used at night with the mask on 9 e Check sum displays information for the medical practitioner or the dealer to check compliance M e Altitude setting displays altitude setting Press A or V to change altitude cmH20 e Pressure setting displays pressure setting PATIENT MENU Additional Settings DISPLAY OPERATION To access additional settings e ThermoSmart Climate setting From the Default sett
3. 11 Allumer l appareil l aide de l interrupteur se trouvant sur le dessus de l appareil Fig 8 La valeur de ThermoSmart Humidit est affich e 12 Pour modifier les param tres consulter le chapitre Contr les et Affichages Votre appareil est pr t l utilisation 8 CONTR LES ET AFFICHAGE 8 1 Affichages Description et Fonction Interrupteur On Off Bouton mont en pression progressive Bouton Haut Augmente la valeur Bouton Bas Diminue la valeur Bouton mode Naviguer entre les options BOUTON DESCRIPTION ET FONCTION FONCTIONNEMENT MARCHE ARRET METTRE EN MARCHE Mise en marche amp arr t e Appuyer sur le bouton CD bri vement e L appareil affiche la valeur de ThermoSmart Humidit par d faut ETEINDRE L APPAREIL e Retirer le masque e Appuyer sur le bouton QD bri vement MODE PROGRESSIF METTRE EN MARCHE R duction de pression pour favoriser e Appuyer sur le bouton J du mode progressif l endormissement Augmentation A noter pour r initialiser le mode progressif lors d un cycle il est n cessaire progressive de la pression la valeur d teindre l appareil pr alablement prescrite apr s 20 minutes ETEINDRE L APPAREIL e Appuyer sur le bouton CD Marche arr t e Utiliser le bouton A et V pour augmenter ou r duire le r glage L 7 1 7 1 p e Appuyez sequentiellement pour visualiser les options disponibles MENU PATIENT AFFICHAGE FONCTIONNEMENT Visualisation des para
4. 3 secondes Regler l altitude a l aide des boutons A ou W Appuyez sur gt pour sortir du menu e Pression d livr e Affichage de la pression d livr e L affichage retourne aux param tres par d faut si vous n tes pas sorti du menu Presser le bouton gt pour sortir du menu disponible sur le HC608 seulement Avertissement si l altitude n est pas s lectionn e correctement quel que soit le lieu la pression d livr e pourra en tre affect e e Lorsque que l on modifie le r glage de conditions ambiantes ThermoSmart le r glage d humidit ThermoSmart retourne 2 5 par d faut B 6 8 2 Sommaire Menu Patient Appuyer pour activer le mode Rampe Appuyer une fois pour allumer arr ter Pappareil Augmenter diminuer BE S Affichage Mode Humidit Dur e totale de Dur e moyenne Ajuster ThermoSmart i f fonct ment J R glage par d faut ii e par nuit l altitude Pression 99 mee M cmH20 Fran ais Retourner aux aleurs par 0 5 Augmentation d faut Humidit Dur e totale de Dur e moyenne ThermoSmart RE fonct t R glage par d faut nn par nuit Pression Retourner aux valeurs par A u hr cmH20 d faut Menu Patient Retourner aux avanc u valeurs par gt p d faut ou V appuyer pendant 3 secondes de de Pression Retourner aux r delivree valeurs par cmH 30 d faut appuyer pendant 3 secondes e Attenti
5. ESPECIFICACIONES EL CTRICAS Frecuencia de alimentaci n 50 60 Hz Voltaje y corriente de alimentaci n ON A max PA 2202210 OA ms 202 Nota estos valores representan la corriente media Requisitos del convertidor de corriente continua a corriente alterna 115 V 200 W 300 W de potencia m xima 230 V 300 W 500 W de potencia m xima Plato calentador max 85 W Temperatura del plato calentador Tubo de respiraci n calentado Par metro de suministro m x 149 F 65 C electrico m x 30 W FUNCIONAMIENTO Rango de presi n 4 a 20 cmH O Rango de altitud 0 a 9000 pies o O a 3000 m Nivel m ximo de flujo Par metro de presi n CPAP cmH O Presi n medida en el puerto de conexi n del paciente cmH O Nivel m ximo de flujo L min en el puerto de conexi n de la mascarilla Estabilidad de la presi n est tica a largo plazo Diferencia de presi n 0 05 a 0 18 cmH20 medida en el puerto de conexi n de la mascarilla en el par metro de presi n de 10 cmH 0O Estabilidad de presi n din mica a corto plazo Par metro de presi n CPAP cmH 0 Diferencia de presi n cmH O en el puerto de conexi n de la mascarilla 30 min 30 mg l Mess 29 87 O Tiempo de calentamiento Humedad suministrada Temperatura del gas medida a 22 C de temperatura ambiente 10 cmH 0 a flujo continuo controlado 16 AP NDICE CUMPLIMIENTO DE LOS EST NDARES Dise ado conforme a los siguie
6. Para prevenir quemaduras evite e Llenar la c mara con agua hirviendo e Tocar el plato calentador expuesto o la base de la c mara e Colocar el tubo de respiraci n de tal forma que entre en contacto de forma prolongada con la piel Para prevenir el riesgo de incendio al utilizar ox geno evite e Activar el flujo de ox geno cuando el dispositivo no est funcionando el ox geno puede acumularse en el interior del dispositivo e Situar el dispositivo en un lugar donde tenga poca ventilaci n e Utilizar el ox geno si est fumando o cerca del fuego e Utilizar cualquier material que se inflame o encienda f cilmente en concentraciones elevadas de ox geno e Mantener cerca del producto cualquier fuente de ignici n Para evitar la ignici n se recomienda mantener cualquier fuente de ignici n fuera de la habitaci n donde se utilice ox geno adicional e Utilizar el dispositivo sin la cubierta del adaptador de puerto serial e Mantener los reguladores de ox geno v lvulas de cilindro tubos conexiones y cualquier otro equipamiento de ox geno cerca de aceites grasa o substancias grasas Si estas sustancias entran en contacto con ox geno bajo presi n pueden ocasionar una ignici n espont nea y violenta Otras e Coloque el dispositivo en una superficie que est a un nivel por debajo de la altura de la cabeza para evitar que el agua entre en el tubo Si el agua llega a entrar en el tubo drene el exceso de l quido
7. Presionar el bot n para presionado para encender activar rampa Aumentar Disminuir Modo Par metro de humedad ThermoSmart por defecto Tiempo total de Promedio de funcionamiento horas de uso Total de control EEN EEN EEL Pantalla Ajuste de altitud Ajuste de la Presi n por noche hr hr lt Volver a ajuste INCREMENTO 0 5 por defecto Par metro de humedad Tiempo total de Promedio de Total de Modelo ThermoSmart N funcionamiento horas de uso HC608 por defecto Pa por noche gt 9 hr Ajuste de la Presi n cmH 90 Volver a ajuste por defecto Menu paciente avanzado Volver a ajuste gt de por defecto Presione durante 3 segundos Aumentar disminuir par metro Climate ThermoSmart Fije la altitud Menu cea Presi n avanzado actual gt cmH 90 Presione durante 3 segundos Volver a ajuste por defecto e Atenci n no eligir la altitud correcta para una ubicaci n en particular tendr un efecto adverso en el suministro de presi n 9 PREGUNTAS M S FRECUENTES Es necesario usar agua destilada con el aparato El uso de agua destilada prolongar la vida til de la c mara de agua El agua del grifo a menudo contiene minerales que pueden da ar la c mara picando la base incluso cuando se filtre el agua Se puede utilizar el equipo en otros pa ses S Simplemente utilice el adaptador de enchufe el ctrico apropiado y el equi
8. 2 para obtener informaci n adicional 10 CONDICIONES DE OPERACI N TEMPERATURA AMBIENTE TS C35 ME HUMEDAD 10 a 95 de humedad relativa HR JANET DS O 3000 m 0 9000 pies A m s de 1500 m 4500 pies se reducir el m ximo de presi n de funcionamiento 11 CONDICIONES DE ALMACENAMIENTO Y TRANSPORTE El equipo deber almacenarse y transportarse en las siguientes condiciones ambientales 14 a 140 F 10 a 60 C 12 SOLUCI N DE PROBLEMAS Si nota que el dispositivo no funciona correctamente consulte a su proveedor de cuidados de la salud No intente reparar el dispositivo usted mismo 13 GARANT A Por favor contacte a su proveedor de productos Fisher amp Paykel Healthcare con relaci n a la garant a 14 INSTRUCCIONES SOBRE COMO ELIMINAR EL DISPOSITIVO Y LOS CONSUMIBLES e Instrucciones sobre c mo desechar la unidad Esta unidad contiene componentes electr nicos No desechar como basura com n Deseche el dispositivo de acuerdo a las directivas locales para el desecho de componentes electr nicos Le Instrucciones sobre c mo desechar los consumibles Y Coloque la mascarilla el tubo de respiraci n y la c mara de agua en una bolsa de basura al final de su vida til y t relos con la basura normal 15 ESPECIFICACIONES DEL PRODUCTO DIMENSIONES 10 7 x 6 7 x 6 9 273 mm x 170 mm x 175 mm PESO 4 6 lbs 2 1 kg s lo unidad 7 5 los 3 4 kg empaquetados en una bolsa que incluye los accesorios
9. E E S A 3 ATEO ga WC MO A A este A 4 o ee ee A ee A 4 DIT EN RG APA q ee A 4 amp 21212 ma MINAS rota A 5 SU AS I ee pee costar A ect rg A geese emt A 5 Sega ee A E E UA AA A 6 oe Droa PSS CUP on ana FUE ONE esca aos A 6 02 Patent A DATA a ne o E POE PEE E E E ES PEO neo A 7 83 Patient Menu Additional Settings SUMMER a A 7 FS Asked O A E E ne ee A 8 Operating SO eter ERE One Se ner men eerie er ey ee ee ee eee A 8 Storage a a Transport COM ANIONS orina A 8 MEE E FEN ENAA EEN ee E ARI A T A 8 WI ee E Un E PE PO o UU O A 8 Device and Consumables Disposal ASTUCES ans A 8 Product prene O AMA A A 9 RE A A E AA selene A 9 PLEASE READ ALL INSTRUCTIONS BEFORE INITIAL USE Caution USA Federal Law restricts this device for sale by or on the order of a physician 1 SYMBOL DEFINITIONS ii E CE O C ow e BP ATTENTION IPX1 Power 93 42 EEC A Consult Drip Proof Alternating Current Class Il On Off Class Ib Applied Part Double Insulated accompanying documents 2 WARNINGS CAUTIONS AND CONTRAINDICATIONS NOTES e This manual refers to the SleepStyle 600 CPAP Series unit as the device If required to use CPAP by a referring physician you should use your device every time you sleep Should your device stop working for any reason contact your healthcare provider immediately e The user of this system shall have sole responsibility and liability for any injury to persons or damage to property resulting from operation o
10. On ee ee ee energie B 5 Vea nn NEE TEERI E EEE NENNEN NENNEN EN IESKLEDEIRNEENEUIEESEEEEINEERSRERSENBERE B 6 Gal Pichia Gece la Descriptiomet d s Fontane een a old B 6 0 2 Omnia ee Men eier B 8 3 Sommaire Menu Patient R glages Suppl mentaires sise B 7 SU ado de eo ae di Dei B 8 Conditions ds once nen rare ia B 8 Ente BO OS SC On ee ee ee ee B 8 Bs 0 AA O A en A B 8 E E AA e ee eier B 8 Instructions pour la mise au rebut l appareil et des consommables oo cecccccccccscssssssessecsecsecsseseesecsecsecseeseesecsestsscseeseeeeeeeess B 8 carac Ss ques ECNI UES ee de B 9 UE eT ener ere SCE een E eee eee ee eee B 9 VEUILLEZ LIRE LES INSTRUCTIONS DANS LEUR TOTALITE AVANT D UTILISER VOTRE APPAREIL POUR LA PREMIERE FOIS _O qe Os qa LL 1 D FINITION DES SYMBOLES O O ME 4 CE 0123 Type BF ATTENTION I o Alimentation lectrique 93 42 EEC Piece utilis e Consulter les Anti coulement Courant alternatif Class II On Off Classe lib documents joints Double isolation 2 AVERTISSEMENTS PRECAUTIONS ET CONTRE INDICATIONS REMARQUES e Ce manuel concerne l appareil SleepStyle serie PPC 600 d sign par l appareil e Si un m decin vous a prescrit un traitement en PPC vous devez utiliser l appareil chaque nuit S il s arr te de fonctionner pour une raison quelconque contactez le prestataire de soins imm diatement e l utilisateur de cet appareil est seul responsable des l sions corporelles ou do
11. du masque cmH O D lai de pr chauffage Humidit d livr e Temp rature du gaz 30 min 30 mg L Mex 37 15 C 98 87 F mesur e une temp rature ambiante de 22 C 10 cmH O un d bit continu 16 APPENDICE Le tableau suivant num re les principales diff rences de fonctionnalit s des produits de la gamme SleepStyle 600 MOD LE PPC Avec Humidificateur Int gr REMARQUES CONFORMIT AUX NORMES Con u pour tre conforme aux exigences des normes IEC 60601 1 UL60601 1 CSA C22 2 No 601 1 AS3200 1 0 EN60601 1 ISO 17510 1 l appareil est conforme aux exigences de compatibilit lectromagn tique CEI 60601 1 2 Dans certains cas l appareil peut affecter ou tre affect par d autres quipements en raison des interf rences lectromagn tiques Si cela se produit d placer l appareil ou l quipement causant l interf rence ou bien consulter votre prestataire de soins Surveillance de l Observance du Patient Ajustement Automatique de l altitude Affichage LCD amp T l chargement Compensation Automatique des Fuites e Tous les mod les sont quip s de la Technologie ThermoSmart Certains mod les ne sont pas en vente dans tous les pays a qe On CS E LL SleepStyle600 CPAP SERIES La serie SleepStyle 600 es una linea de CPAP cuenta con humidificaci n calentada y un tubo respiratorio calentado integrados Ha sido dise ada para
12. e Faire fonctionner le dispositif s il est tomb ou s il est endommag e Utiliser le dispositif s il ne fonctionne pas correctement e Ajuster la pression La pression doit tre ajust e uniquement par un prestataire de soins e Faire fonctionner l appareil si le circuit respiratoire a t endommag et comporte des trous des d chirures ou s il a t pli e Bloquer le d bit de fuite du masque e Utiliser le masque si l appareil est teint ou ne fonctionne pas correctement e Utiliser un manchon isolant ou tout autre accessoire similaire qui ne sont pas approuv s par Fisher amp Paykel Healthcare Ils peuvent affecter les performances d humidification e Essayer d enlever le circuit respiratoire chauff sans tirer vers le haut le manchon d abord Cela permettra d viter d endommager le raccord Pour viter les br lures ne pas e Remplir la chambre avec de l eau bouillante e Toucher la plaque chauffante ou la base de la chambre e Placer le circuit respiratoire de telle mani re qu il puisse entrer en contact prolong avec la peau Pour viter les risques d incendie lors de l utilisation d oxyg ne ne pas e Ouvrir l alimentation d oxyg ne lorsque l appareil n est pas en fonctionnement cela peut conduire une accumulation d oxyg ne dans l appareil e Mettre l appareil un endroit o la circulation d air autour de l appareil est limit e e Utiliser l oxyg ne lorsqu une personne fume ou en pr
13. is preset to 2 which is suitable for most patients Note if the climate setting is adjusted the humidity setting will revert back to the default setting e ThermoSmart Climate setting 3 is recommended for oral CPAP delivery e If you feel the range of settings offered by the ThermoSmart Humidity Setting are too dry or too cool Increase the ThermoSmart Climate setting e If you feel the range of settings offered by the ThermoSmart Humidity Setting are too warm or too humid Reduce the ThermoSmart Climate setting It is recommended to keep the heated breathing tube on top of bedding for the best humidity performance To operate ThermoSmart Humidity and Climate settings refer to section 8 Controls and Display of this manual 4 INTENDED USE The device is used to assist with patient breathing while sleeping for the purpose of treating Obstructive Sleep Apnea OSA This is done by the delivery of Continuous Positive Airway Pressure CPAP in order to prevent airway obstruction The addition of heated respiratory humidification to the device relieves the drying and irritating effects on the patient airways which usually arises from use of a CPAP system The device is for use on adult patients at home or in the sleep lab Please refer to the SleepStyle 600 Series product range listed in the appendix section of this manual 5 OXYGEN USE WARNINGS If oxygen is required it is recommended that supplemental oxygen be adm
14. minutos el interior de la c mara en una soluci n de 1 parte de vinagre blanco en dos partes de agua y enjuague bien con agua destilada 5 MANTENIMIENTO e Cambie el filtro de aire cuando haya perdido su color de forma considerable al menos una vez cada 3 meses o tras 1000 de horas de funcionamiento del aparato Para hacer esto extraiga el portafiltro de la parte posterior del equipo como se muestra en el Gr fico 2 Aseg rese de que la l nea negra vertical del nuevo filtro est colocada mirando hacia el equipo y vuelva a ajustar ambos al equipo e Cambie la c mara si sta est agrietada ha perdido el color o se ha rayado e Cambie el tubo de respiraci n calentado despu s de 4000 horas de uso o una vez por a o Si el tubo est da ado hay que cambiarlo inmediatamente 7 INSTRUCCIONES DE OPERACI N Cuando la c mara est instalada y llena el equipo debe mantenerse en posici n vertical para que el agua no entre en su interior 1 Retire el equipo de su embalaje 2 Coloque del equipo sobre un estante bajo o en el suelo junto a la cama La unidad debe colocarse a un nivel inferior a la altura de su cabeza 3 Retire la c mara de agua de su embalaje 4 Retire los tapones azules y des chelos Gr fico 1 5 Llenar la c mara hasta la l nea de agua nicamente con agua destilada Gr fico 2 No llene nunca la c mara a trav s del puerto conector del tubo calentado Cuando mueva su equipo aseg rese de que la c mara de
15. sence d une flamme nue e Utiliser des mat riaux qui br lent dans l air ou qui s enflamment facilement en pr sence d une forte concentration d oxyg ne e Mettre l appareil c t d une source d embrasement Pour viter l embrasement il est pr f rable d loigner toutes les sources d embrasement de la pi ce o l alimentation d oxyg ne est utilis e e Entreposer des d tendeurs robinets circuits raccords et autre quipement d alimentation en oxygene pres d huile de graisse ou d autres substances graisseuses Un embrasement violent et spontan peut se produire si ces substances entrent en contact avec de l oxyg ne sous pression e Faire fonctionner l appareil sans le couvercle sur l adaptateur de port s rie Autre e Placer l appareil sur une surface plane en dessous du niveau de la t te pour pr venir toute p n tration d eau dans le tube Si de l eau a p n tr dans le tube enlever l exc s de condensation De l eau dans le tube peut provoquer une aspiration e l appareil est destin tre utilis avec des masques PPC et des raccords qui ont des orifices de fuite pour permettre l vacuation continue de l air hors du masque Lorsque l appareil est en marche et fonctionne correctement le d bit d air frais vacue l air expir du masque par les orifices de fuite pression PPC faible et en cas de panne de courant ou de dysfonctionnement de l appareil retirer imm diatement le masque puisque la circula
16. ser utilizada en el laboratorio del sue o y en el hogar para el tratamiento de la Apnea Obstructiva del Sue o Para m s ayuda p ngase en contacto con la oficina local de Fisher amp Paykel Healthcare las direcciones se encuentran en la cubierta posterior S rvase guardar este manual para futuras consultas NDICE DE MATERIAS en 10 11 12 13 14 15 16 eara ss A ee C 2 Advertencias precauciones y contraindicaciones sise EZ Bi ae age 1 12 17 10 PPP A e o E NER NL eT E EIN OR ey are eee eee C 3 Sm Conenido o o O A a be de ta a A D ei C 3 3 2 Piezas MPOH EN SA HE Dee ee ee nee C 3 SE AP o eier C 3 ceo E o ee A A C 4 Uso para el que ha sido SENADO tinas C 4 Advertencias sobre el uso de ASNO ana C 4 ia a o D an D ne C 5 mnstucciones COR can oia ette C 5 Controles ee ee re ee C 6 9 Pamala desc peon UNO odas C 6 8 2 Resumen Menu Paciente an Gay 8 3 Resumen Men Pacientes Alustes adicionales ne C 7 A SM O da a na nen ie ne di ed C 8 Condiciones de ODA ORR IEERNIRE ACER C 8 Condiciones d almacenamiento y transporte ana C 8 o Mere e OD A ee nen C 8 PP e eier C 8 Instrucciones sobre como eliminar el dispositivo y los consumibles nnnenensenensesnnensenennenne nennen C 8 ESpPeciicaci nes del Bel accord das ee O he 0 la C 9 AA ita C 9 POR FAVOR LEA TODAS LAS INSTRUCCIONES ANTES DE USAR POR PRIMERA VEZ 1 DEFINICI N DE LOS S MBOLOS m ME i CE 0123 Tipo BF ATENCION nn Interruptor
17. 0 3205 2132 France Tel 33 1 6446 5201 Fax 33 1 6446 5221 Germany Tel 49 7181 98599 O Fax 49 7181 98599 66 India Tel 91 80 4284 4000 Fax 91 80 4123 6044 Irish Republic Tel 1800 409 011 Italy Tel 39 06 7839 2939 Fax 39 06 7814 7709 Japan Tel 81 3 3661 7205 Fax 81 3 3661 7206 Northern Ireland Tel 0800 132 189 Spain Tel 34 902 013 346 Fax 34 902 013 379 Sweden Tel 46 8 564 76 680 Fax 46 8 36 63 10 Switzerland Tel 0800 83 47 63 Fax 0800 83 47 54 Taiwan Tel 886 2 8751 1739 Fax 886 2 8751 5625 Turkey Tel 90 312 354 34 12 Fax 90 312 354 31 01 UK EU Authorised Representative Fisher amp Paykel Healthcare Ltd Unit 16 Cordwallis Park Clivemont Road Maidenhead Berkshire SL6 7BU UK Tel 44 1628 626 136 Fax 44 1628 626 146 USA Tel 1 800 446 3908 or 1 949 453 4000 Fax 1 949 453 4001 185044288 REVE 2010 10 O 2010 Fisher 8 Paykel Healthcare Limited
18. AGAR e Retire la m scara e Presione brevemente el bot n 0 RAMPA PARA ENCENDER Reduce la presi n a un nivel inferior e Presionar el bot n J para ayudar al paciente a dormir Nota para reajustar el modo progresivo durante el ciclo es necesario primero La presi n volver gradualmente apagar el equipo a la presi n de operaci n total en PARA APAGAR 20 minutos N e Presione el bot n AUMENTAR DISMINUIR Para ajustar los niveles hacia arriba o e Utilizar el bot n A y V para aumentar o bajar los ajustes hacia abajo MODO Avance las opciones e Pulse en secuencia para avanzar y ver las opciones disponibles MEN PACIENTE PANTALLA OPERACI N Para visualizar los par metros de PARA VISUALIZAR PUNTOS CPAP la humedad los datos sobre el Presionar la tecla gt para visualizar en secuencia cumplimiento par metros de altitud y presi n e Par metro de humedad ThermoSmart ajuste est ndar Para cambiar los niveles de humedad ThermoSmart para minimizar los efectos colaterales a las v as respiratorias superiores debido al uso de CPAP Presione los botones A y V para subir o bajar los par metros e Tiempo total de funcionamiento presenta el n mero total de horas que el equipo estuvo encendido incluso el n mero de horas en que la m scara no ha sido utilizada e Promedio de horas de uso por noche presenta el n mero promedio de horas en que el equipo ha sido utilizado con la m scara durante la noc
19. Accessories HC365 Standard Humidification Chamber 900HC240 Filter 2 Pack HC360 Extended Life Humidification Chamber 900HC604 Outlet Cleaning Kit HC600 900HC522 ThermoSmart Heated Breathing Tube 900HC627 Elbow Funnel 10 Pack TOM 22 mm 86 eonlealeonneecr Not available in all countries 3 4 ThermoSmart Technology This device has been designed for optimal patient comfort and offers the unique heated breathing tube technology ThermoSmart ThermoSmart Technology allows for the delivery of optimal higher and customized levels of humidity to the patient independent of ambient temperature This device can be adjusted on two levels to achieve optimal comfort ThermoSmart Humidity setting this setting regulates the temperature of the heater plate adjusting the humidity levels for the comfort of the patient Adjustment can be made from 1 to 4 with increments of 0 5 The device is preset to 2 5 which is suitable for most patients e If you experience dryness or find the air too cool increase the setting e If you find there is too much moisture in the tube or the air feels too hot decrease the setting e If you do not achieve optimal comfort with this setting further adjustments can be made by altering your ThermoSmart Climate setting ThermoSmart Climate setting this setting provides further adjustment options by optimizing the delivered humidity Adjustment can be made from 1 to 3 with increments of 1 The device
20. El agua presente en el tubo podr a ser aspirada e El dispositivo est dise ado para utilizarse con mascarillas y conectores CPAP que tengan orificios de flujo de escape para permitir el flujo continuo de aire fuera de la mascarilla Cuando el dispositivo est encendido y funcionando correctamente el aire nuevo elimina hacia fuera el aire exhalado a trav s de los orificios del flujo de escape de la mascarilla A presiones CPAP bajas y en caso de fallos en el suministro el ctrico o mal funcionamiento del equipo retire la mascarilla de inmediato ya que el flujo de la mascarilla puede ser insuficiente para eliminar todo el gas exhalado y la reinhalaci n del CO puede llegar a ser peligrosa e Sino se selecciona el nivel de altitud correcto en una ubicaci n determinada se producir un efecto negativo en el suministro de presi n e Este dispositivo no est dise ado para el soporte vital e Evite retirar innecesariamente el cable el ctrico de la parte posterior del dispositivo Si fuera necesario retirarlo sujete el conector y ret relo Evite tirar del cable el ctrico consulte la Secci n 3 2 PRECAUCIONES Para evitar que el agua da e el dispositivo e Extraiga la c mara de humidificaci n del dispositivo antes de llenarla e Vac e el agua de la c mara antes de transportar el dispositivo Si fuera necesario manipular el dispositivo con agua en la c mara evite inclinarlo para que no entre agua en su interior Otra
21. Encendido 93 42 EEC Pieza aplicada Consult l prueba de Corriente alterna Clase Il Doble Apagado Clase II documentaci n salpicaduras aislamiento adjunta 2 ADVERTENCIAS PRECAUCIONES Y CONTRAINDICACIONES NOTAS e Este manual se refiere al modelo CPAP de la serie SleepStyle 600 como el dispositivo e Si el m dico de cabecera le prescribe el uso de un equipo CPAP debe usar el dispositivo siempre que duerma En caso de que el dispositivo deje de funcionar por cualquier raz n p ngase en contacto de inmediato con su proveedor de cuidados de la salud e El usuario de este sistema ser el nico responsable de las lesiones a personas o da os a la propiedad que se puedan derivar de un uso del dispositivo que no se ajuste a las instrucciones de operaci n que se proporcionan e El dispositivo s lo debe utilizarse con mascarillas conectores y tubos de suministro conformes con la norma ISO 17510 2 y recomendados por Fisher amp Paykel Healthcare o por su proveedor de cuidados de la salud e No utilice el dispositivo si la temperatura ambiente sobrepasa los 35 C ya que en tal caso la temperatura del flujo de aire podr a ser excesiva y dar lugar a una irritaci n de las v as respiratorias e Informe de todas las reparaciones y mantenimiento a Fisher amp Paykel Healthcare ADVERTENCIAS Para prevenir descargas el ctricas causadas por el dispositivo evite e Utilizar el dispositivo si el cable el ctrico o el
22. HERMOSMART N CONECTOR CON MANGA PUERTO CONECTOR DE TUBO DE RESPIRACION CALENTADO THERMOSMART FILTRO DE AIRE PLATO CALENTADOR PANTALLA C MARA DE AGUA Y KO PROTECTOR DE LOS DEDOS 4 EMBUDO NIVEL DE LLENADO DE AGUA vertical MARCA DEL NIVEL DE AGUA 3 3 Accessorios HC365 C mara de humidificaci n est ndar 900HC240 Filtro paquete de 2 HC360 C mara de humidificaci n larga vida 900HC604 Kit de limpieza de la salida HC600 900HC522 Tubo de respiraci n calentado ThermoSmart 900HC627 Paquete de 10 embudos de codo para conector c nico de 22 mm No disponible en todos los pa ses 3 4 Tecnolog a ThermoSmart Este equipo se ha dise ado para lograr mejor confort y ofrece la tecnologia Unica ThermoSmart de tubo de respiraci n calentado La tecnolog a ThermoSmart permite el suministro de mejores niveles m s elevados y personalizados de humedad para el paciente independientemente de la temperatura ambiente En este mecanismo se pueden ajustar dos niveles para lograr mejor confort Par metro de humedad ThermoSmart este par metro regula la temperatura del plato calentador ajustando los niveles de humedad para el confort del paciente El ajuste se puede realizar de 1 a 4 con incrementos de 0 5 por vez El dispositivo ha sido configurado por defecto a 2 5 que es adecuado para la mayor a de los pacientes e Si siente sequedad o encuentra el aire muy fr o aumente el intervalo de p
23. QUE HA SIDO DISE ADO El equipo se utiliza para ayudar a respirar al paciente mientras duerme para el tratamiento de la Apnea Obstructiva del Sue o AOS Esto se consigue mediante el suministro de Presi n Positiva y Continua a las V as Respiratorias CPAP para evitar la obstrucci n de las v as respiratorias El a adir humidificaci n respiratoria calentada al aparato alivia los efectos de sequedad e irritaci n de las v as respiratorias del paciente que suelen derivarse del uso del sistema CPAP El equipo es para ser utilizado por pacientes adultos en su domicilio o en el laboratorio del sue o Por favor vea la lista de Productos de la Serie SleepStyle 600 que se encuentra en el Ap ndice de este manual 9 ADVERTENCIAS ACERCA DEL USO CON OX GENO Si se requiere ox geno se recomienda administrar el ox geno adicional por la mascarilla Consulte las instrucciones espec ficas para cada tipo de mascarilla NOTA e una tasa fija de flujo de ox geno adicional la concentraci n de ox geno inhalado variar dependiendo de los par metros de presi n fijados el patr n respiratorio del paciente la mascarilla seleccionada y la tasa de fugas Antes de utilizar ox geno con el dispositivo vea las advertencias relacionadas con el ox geno en la Secci n 2 6 LIMPIEZA Y MANTENIMIENTO ATENCION hay que limpiar el equipo seg n sea necesario 1 Apague el dispositivo y desenchufelo de la toma de corriente Espere hasta que el agua
24. SleepStyle600 CPAP SERIES Operating Manual Fisher Paykel HEALTHCARE SECTION FEANCAIS nee e EE O OR A B ESPANOE E OE O ER A C This product is covered by one or more of the following patents or patent applications in the corresponding countries listed below HC604 USA US6598604 US6398197 US7111624 US6953354 US7086399 US7616871 Australia AU761713 AU756477 AU2003204474 AU2003265025 AU2004266551 AU2009201906 Japan JP4436758 Europe EP 1369141 EP1542757 EP1656173 EP1055431 GB IT Hong Kong HK1074178 HC608 USA US6598604 US6398197 US7111624 US6953354 US7086399 US7616871 Australia AU761713 AU756477 AU2003204474 AU2003265025 AU2004266551 AU2009201906 Japan JP4436758 Europe EP1369141 EP1542757 EP1656173 EP1055431 GB IT Hong Kong HK1074178 SleepStyle600 CPAP SERIES The SleepStyle 600 CPAP Series has integrated heated humidification and a heated breathing tube It is designed for use in the home or sleep laboratory for the treatment of Obstructive Sleep Apnea For further assistance please contact your local Fisher amp Paykel Healthcare office see back cover for details Please keep this manual for future reference TABLE OF CONTENTS E ie 10 11 12 13 14 15 16 A A AA A 2 Warnings Cautions and EC ont ande ton ee an A 2 Dee Don olihe Device een Dre E ee ee A 3 O O oia A 3 32 importam Parts Ol the Dee a a a a A 3 AE S E E E E E E E N E E
25. agua se encuentre vac a Los fallos de la m quina debidos a da os provocados por agua no est n cubiertos por la garant a 6 Para fijar la c mara de agua al aparato presione la protecci n de los dedos y deslice la c mara Gr ficos 3 y 4 7 Cuando la c mara est correctamente colocada la protecci n para los dedos volver a su posici n con un clic 8 Uno de los extremos del tubo calentado tiene un conector pl stico gris Levante la vaina y deslice el conector sobre el aparato Empuje la vaina hacia abajo para bloquear Gr ficos 5 6 y 7 Conecte el otro extremo del tubo calentado a la mascarilla 10 Enchufe el cable el ctrico del equipo en un tomacorriente dom stico normal 11 Encienda el equipo pulsando y manteniendo presionado el bot n de encendido apagado Gr fico 8 La pantalla indica el par metro de humedad ThermoSmart 12 Para cambiar el par metro consulte la secci n 8 Controles y Pantalla El equipo se encuentra ahora listo para el uso Gr fico 7 C 5 8 CONTROLES Y PANTALLA 8 1 Pantalla descripci n y funciones Bot n de Encendido Apagado Bot n de subida Aumentar ajuste Bot n de bajada Disminuir ajuste Bot n de modo Avance las opciones BOTON DESCRIPCI N Y FUNCI N OPERACI N ENCENDIDO APAGADO PARA ENCENDER Encendido y apagado del equipo e Presionar el bot n CD brevemente e El aparato presentar el par metro de humedad ThermoSmart PARA AP
26. d entonnoir x10 s adapte un raccord conique de 22 mm 0 86 Non disponible dans certains pays MZ qe Os CS LL 3 4 Technologie ThermoSmart Cet appareil comporte la technologie du circuit chauffant ThermoSmart con u pour un confort patient optimal et une distribution d humidit optimale plus lev e et personnalis e ind pendamment de la temperature ambiante Cet appareil peut tre r gl deux niveaux pour un confort optimal Param tres d Humidit ThermoSmart ces param tres contr lent la temp rature de la plaque chauffante en ajustant le degr d humidit pour le confort du patient Il est possible d ajuster la valeur de 1 4 par incr ments de 0 5 L appareil est programme 2 5 ce qui est acceptable pour la plupart des patients e En cas de sensation de s cheresse ou de froideur augmenter le r glage e l inverse diminuer si l humidit est trop importante ou si l air est trop chaud e Si le confort n est pas optimal apr s avoir modifi ces param tres il est possible de modifier les valeurs de Conditions ambiantes du ThermoSmart R glages climat ThermoSmart ce r glage permet des possibilit s d adaptation suppl mentaires en optimisant l humidit d livr e Il est possible d ajuster la valeur de 1 3 par incr ments de 1 L appareil est programme 2 ce qui est acceptable pour la plupart des patients Remarque si les param tres de conditions ambiantes son
27. e ou ray e e Remplacer le circuit chauffant apr s 4000 heures d utilisation ou une fois par an Remplacer tout circuit endommag imm diatement 7 INSTRUCTIONS D INSTALLATION Lorsque la chambre est mise en place et remplie l appareil doit rester la verticale pour viter la p n tration d eau Francais 1 Retirer l appareil de son emballage 2 Placer l appareil sur une tag re basse ou par terre c t de votre lit Placer l appareil une hauteur inf rieure celle de votre t te 3 Retirer la chambre d humidification de son emballage Retirer et jeter les capuchons bleus Fig 1 5 Remplir la chambre jusqu la ligne de remplissage avec de l eau distill e Fig 2 Ne jamais remplir la chambre travers la prise du connecteur du circuit chauffant Lors du transport de l appareil toujours s assurer que la chambre est vide La garantie ne couvre pas les dommages occasionn s par l eau 6 Pour attacher la chambre d humidification l appareil appuyer sur la protection et y glisser la chambre Fig 3 Fig 4 7 Lorsque la chambre est plac e correctement la protection s enclenche 8 Une des extr mit s du circuit chauffant poss de un connecteur gris en plastic Soulever le manchon et glisser le connecteur sur l appareil Pousser le manchon vers le bas pour le bloquer Fig 5 6 et 7 Connecter l autre extr mit du circuit chauffant au masque 10 Brancher l appareil la prise murale
28. enchufe est n da ados e Utilizar el dispositivo si se ha ca do al agua e Enchufar el dispositivo a la toma de corriente si est h meda e Limpiar el dispositivo mientras est conectado a la toma de corriente e Guardar o utilizar el dispositivo donde se pueda volcar tirar o caer al agua Si ha entrado agua en el interior del dispositivo desconecte el cable el ctrico y deje de utilizarlo Consulte con Fisher amp Paykel Healthcare Para evitar atragantarse o inhalar un cuerpo extra o e No coloque objetos en ninguna apertura del tubo e Aseg rese de que el filtro de aire est colocado en el dispositivo cuando lo est utilizando Para asegurar una terapia ptima evite e Utilizar el dispositivo si se ha ca do o est da ado e Utilizar el dispositivo si no funciona correctamente e Ajustar la presi n s lo puede ajustarla el personal sanitario e Utilizar el dispositivo si el tubo de respiraci n est da ado y tiene orificios desgarros o est retorcido Bloquear el flujo de escape de la mascarilla e Usar la mascarilla si la unidad est apagada o no funciona correctamente e Utiliza una manga aislante o cualquier accesorio similar que no est autorizado por Fisher amp Paykel Healthcare Tales accesorios pueden afectar al funcionamiento de la humidificaci n e Intentar retirar el tubo de respiraci n calentado sin presionar antes la manga hacia arriba para evitar que se da e el puerto de conexi n
29. er filling line with distilled water only Fig 2 Never fill the chamber through the heated breathing tube connector port When moving your device ensure that the water chamber is empty Machine failure due to water damage is not covered by warranty To attach the water chamber to the device press down the finger guard and slide the chamber on Figs 3 and 4 When the chamber is fitted correctly the finger guard will click into place One end of the heated breathing tube has a grey plastic connector Lift the sleeve and slide connector on to the device Push the sleeve down to lock Figs 5 6 and 7 Connect the other end of the heated breathing tube to the mask Plug the device power cord into your household power socket Switch on the device by pressing the on off button Fig 8 The current ThermoSmart Humidity setting is displayed For changing the setting refer to section 8 Controls and Display Your device is now ready for use 8 CONTROLS AND DISPLAY 8 1 Display Description and Functions On Off button Ramp button Up button Increase Setting Down button Decrease Setting Mode button Step through the options FUNCTION amp DESCRIPTION OPERATION ON OFF TO SWITCH ON Switches the device ON and OFF e Press CD button down briefly e The device will default to display the ThermoSmart Humidity setting TO SWITCH OFF e Remove your mask e Press CD button briefly RAMP TO SWITCH
30. es performances d humidit optimales qu offre l appareil L appareil n affichera pas le symbole du circuit chauffant mais affichera u Que se passe t il avec l appareil en cas de panne de courant Retirer le masque imm diatement Apr s le retour du courant l appareil red marrera avec le m me mode de fonctionnement et avec les m mes r glages qu avant la panne Se reporter au chapitre 2 pour des informations suppl mentaires 10 CONDITIONS DE FONCTIONNEMENT TEMP RATURE AMBIANTE 53 35 C 41 95 F HUMIDIT 10 95 d humidit relative HR ALTITUDE O 3000 m 0 9000 pieds Au dessus de 1500 m 4500 pieds la pression maximale sera r duite 11 CONDITIONS DE STOCKAGE ET DE TRANSPORT l appareil doit tre entrepos et transport une temp rature ambiante allant de 10 60 C 12 D PANNAGE En cas de doute sur le fonctionnement de l appareil contacter votre prestataire de soins Ne tentez pas de r parer vous m me l appareil 13 GARANTIE Veuillez contacter votre Prestataire de service Fisher amp Paykel Healthcare 14 INSTRUCTIONS POUR LA MISE AU REBUT DU DISPOSITIF ET DES CONSOMMABLES e Instructions pour l limination du dispositif Ce dispositif contient des pi ces lectroniques Ne pas le jeter avec les ordures m nag res L liminer conform ment aux directives locales concernant l limination des d chets lectroniques Ee Instructions pour l limination des consom
31. f the device which is not in accordance with the operating instructions supplied e The device should only be used with ISO 17510 2 compliant masks connectors and delivery tubes recommended by Fisher amp Paykel Healthcare or your healthcare provider e Do not use the device when the room temperature exceeds 95 F 35 C as this may lead to an elevated airflow temperature which may give rise to an irritation of the airways e Refer all repairs and maintenance to Fisher amp Paykel Healthcare WARNINGS To avoid electric shock from your device do not e Operate the device if the power cord or plug is damaged Operate the device if it has been dropped in water Plug the device into the power socket if it is wet Clean the device while connected to the power socket Store or use the device where it can tilt fall or be pulled into water If water has entered the unit enclosure disconnect the power cord and discontinue use Seek advice from Fisher amp Paykel Healthcare To avoid choking or inhalation of a foreign body e Never place any object into any opening of the tube e Ensure the air filter is fitted during device use To ensure optimal therapy do not e Operate the device if dropped or damaged e Operate the device if it is not working properly e Adjust the pressure Pressure must only be adjusted by a healthcare professional Operate the device if the breathing tube has been damaged with holes tears or kinks
32. fault Return to Default Return to Default e Warning Failure to select correct altitude setting for any given location will have an adverse effect on delivered pressure 9 FREQUENTLY ASKED QUESTIONS Do have to use distilled water with my device The use of distilled water will maximize the life of the water chamber Water from the faucet will often contain minerals which can damage the chamber causing pitting in the base even if the water is passed through a filter Can use my device in other countries Yes Simply use the appropriate electrical socket adaptor and the device will automatically adapt to any voltage supply Note When moving your device ensure that the water chamber is empty Machine failure due to water damage is not covered by warranty Can use supplemental oxygen with my device Yes oxygen can be administered at the mask Turn the device on before turning on the oxygen Ensure that the oxygen source is turned off before turning off the device to avoid oxygen accumulating in the machine When do I replace my water chamber Replace the chamber it the plastic walls of the chamber become cracked or cloudy or the chamber base becomes pitted Note If the chamber leaks at all it should be replaced immediately Can use my device without a heated breathing tube Yes you can but you will not gain the optimum humidity performance the device offers The device will then not display the heated breathing tube
33. he i e El total de control presenta la informaci n referente a la conformidad para uso m dico o para el distribuidor A e Ajuste de altitud presenta el ajuste de altitud Presione A o V para cambiar el nivel de altitud cmH20 e Ajuste de la presi n presenta el ajuste de presi n MENU PACIENTE Ajustes Adicionales PANTALLA OPERACI N Para acceder a ajustes adicionales e Par metro clim tico ThermoSmart Desde el ajuste por defecto Para modificar la temperatura suministrada presione N para calentar m s el suministro de HUMEDAD aire Presione W para hacer m s fr o y seco el suministro de aire V ase la secci n 3 4 THERMOSMART e Unidad de altitud Seleccione m de metros o PAL p de pies utilizando las teclas A y W Presione la tecla gt durante 3 segundos e Ajuste de altitud Ajustar el nivel de altitud presionando las teclas A y V Presione gt para salir del men e Presi n actual Presenta la presi n actual La pantalla vuelve al par metro por defecto si no se sale del men Presione el bot n gt para salir del men s lo disponible en HC608 Atenci n No eligir la altitud correcta para una ubicaci n en particular tendr un efecto adverso en el suministro de presi n e Cuando el par metro clim tico ThermoSmart se modifica el par metro de humedad ThermoSmart volver al par metro por defecto 2 5 C 6 8 2 Resumen Men Paciente Pulsar y mantener
34. in Humidity delivered Sima ES Gas Temperature max 93 37 F 7 15 16 measured at 22 C ambient temperature 10 cmH 0 at bias flow 16 APPENDIX The following table lists the main difference in features across the SleepStyle 600 Product Range MODEL Fully Integrated CPAP with Patient Compliance Auto Altitude Adjustment Heated Humidification Monitoring LCD amp Download Leak Compensation woa A oo AO NE NOTE e All models are fully integrated with ThermoSmar pon Technology O Some models are not available for sale in all countries SleepStyle600 CPAP SERIES Les PPC SleepStyle 600 Series comportent un humidificateur chauffant int gr muni d un circuit chauffant convenant aussi bien une utilisation domicile que dans les laboratoires du sommeil pour le traitement du Syndrome d Apnee du Sommeil Pour plus d informations veuillez contacter votre Bureau local F amp P voir coordonn es au verso Conserver ce manuel pour futures r f rences TABLE DES MATI RES Ya PL 9 10 11 12 13 14 15 16 D ni Ones Bol A ain nn ces E EEE B 2 Avertissements pr cautions et contre indications suisses B 2 Descipion de Re a er B 3 AE o OR A it cie B 3 3 2 Elements importants de l appareil nee een B 3 E A o A E A NEE E ee E N B 3 3A Tecno MO na E a e A S EIAS A este B 4 NSIS NS escenario B 4 Precautions lors de Full sat on COX GONG ee B 4 NES des CENSO B 5 Stiel or Pour Tins
35. ing To change the delivered temperature Press A for warmer more humid air THERMOSMART 04 delivery Press V for cooler and drier air delivery Refer to Section 3 4 HUMIDITY e Altitude Select m for metres or ft for feet using A and V keys Press the D gt key for 3 seconds e Altitude setting Set the altitude level by pressing A and V keys Press P gt to exit menu e Actual Pressure Displays actual pressure Display reverts to default if the menu is not exited Press P gt button in order to exit menu only available in HC608 Warning Failure to select correct altitude setting for any given location will have an adverse effect on delivered pressure e When the ThermoSmart Climate setting is altered the Humidity Setting will revert back to default setting 2 5 A 6 8 2 Patient Menu Summary Press to activate Ramp Increase Decrease MI Mode ThermoSmart Humidity Setting Average Hours i int default Total Run Time Lp per night hr 0 5 Increment ThermoSmart Average Hours Humidity Setting g r gt _ Total Run Time Le per night hr lt Advanced Patient Menu Hold for 3 seconds Increase Decrease ThermoSmart Climate Setting Advanced Actual Patient Menu Pressure gt cmH 90 Hold for 3 seconds Press once to switch device on off Display Altitude Setting Pressure Setting cmH 90 Return to Default Pressure Setting Return to cmH 0 De
36. inistered at the mask Please see instructions specific to your mask type NOTE e Ata fixed flow rate of supplemental oxygen the inhaled oxygen concentration will vary depending on the pressure settings patient s breathing pattern mask selection and leak rate Before using oxygen with the device please see oxygen warnings in Section 2 6 CLEANING AND MAINTENANCE PLEASE NOTE The device should be cleaned as required 1 2 l When the chamber is fitted and filled the device must remain upright so that water cannot enter the enclosure T A gt 11 12 Switch off the device and unplug from the power socket Wait for the water to cool then remove chamber Wipe the exterior of the device with a clean damp not wet cloth and mild dishwashing detergent Do not use harsh abrasives or solvents as these may damage the device DAILY Clean the chamber heated breathing tube and heated breathing tube connection port e Remove the heated breathing tube from the device by pulling the sleeve upwards to unlock the connector Then remove the connector e Wash the heated breathing tube with soapy water rinse and then hang up the heated breathing tube with its ends pointing to the floor to dry e Remove the chamber by pushing down the finger guard and pulling out the chamber e Pour out and discard the remaining water e For standard HC365 chambers clean and wash with soapy water then rinse and dry e The e
37. kg unit only sauces E E UL60601 1 7 5 lbs 3 4 kg packaged in bag incl CSA C22 2 No 601 1 accessories AS3200 1 0 ELECTRICAL RATINGS EN60601 1 Supply Frequency 50 60 Hz ISO 17510 1 Supply Voltage and Current 100 115 V 1 5 A max 1 7 A 220 240 V 1 0 A max 2 0 A Note These values represent average current DC to AC Inverter The device complies with the electromagnetic compatibility requirements 115 V 200 W 300 W surge requirements of IEC 60601 1 2 In certain circumstances the device 230 V 300 W 500 W surge may affect or be affected by nearby equipment due to the effects of Heater Plate max 85 W electromagnetic interference If this should happen try moving your Heater Plate Temperature max 149 F 65 C unit or the location of the device causing interference or alternatively Heated breathing tube consult your healthcare provider Power Setting max 30 W PERFORMANCE Pressure Range 4 to 20 cmH20 Altitude Range O to 9000 ft or O to 3000 m Maximum Flow Rates CPAP Pressure Setting cmH O Measured pressure at the patient connection port cmH 0 Maximum flow rate L Min at mask connection port Static Pressure Stability long term 0 05 to 0 18 cmH 0 pressure difference measured at the mask connection port at the pressure setting of 10 cmH O Dynamic Pressure Stability short term CPAP Pressure Setting cmH O Pressure Difference cmH O at mask connection port Warm up time 30 m
38. m tres PPC VISUALISER LES VALEURS numidit donn es d observance Appuyer sur le bouton P gt pour visualiser s quentiellement i e La valeur d humidit ThermoSmart param tres par d faut Pour minimiser les effets secondaires subis par les voies a riennes sup rieures provoqu s par l utilisation de PPC ajuster l humidit ThermoSmart Changer la temp rature l aide des boutons A et V e Dur e totale de fonctionnement affiche la dur e totale de fonctionnement de l appareil comprenant la dur e d utilisation sans le masque e Dur e d observance moyenne par nuit affiche la dur e moyenne d utilisation avec un masque e Chiffre cl affiche des informations de contr le d observance destin es au praticien ou prestataire e R glage d altitude displays altitude setting affiche le r glage d altitude Changer l altitude l aide des boutons A et Y 7 Y 1 e R glage de la Pression affiche le r glage de la pression Menu Patient R glages suppl mentaires AFFICHAGE FONCTIONNEMENT Pour acc der aux r glages e ThermoSmart Climat additionnels Appuyer sur A pour un air plus chaud et humide Appuyer sur V pour un air A partir de la valeur d HUMIDIT plus froid et sec Se r f rer a la section 3 4 par d faut THERMOSMART e Altitude 44 S lectionner m pour metres ou ft pour pied l aide des SER boutons A ou V Appuyer sur P gt pendant e R glage de l altitude
39. mables Y Placer le masque le circuit respiratoire et la chambre d humidification dans un sac poubelle la fin de l utilisation et les jeter avec les ordures m nageres 15 CARACT RISTIQUES TECHNIQUES DIMENSIONS POIDS 273 mm X 170 mm x 175 mm 1072677269 2 1 kg 4 6 lbs appareil seul 3 4 kg 7 5 lbs emball dans un sac accessoires compris CARACTERISTIQUES ELECTRIQUES Fr quence d alimentation Tension d alimentation et intensit Crit res de l onduleur CC en CA Plaque chauffante Temp rature de la plaque chauffante R glage d alimentation du de 50 60 Hz de 1 5 1 7 100 115 V max de 1 0 2 0 A 220 240 V max REMARQUE ces valeurs repr sentent l intensit moyenne Surtension 115 V 200 W 300 W Surtension 230 V 300 W 500 W max 85 W max 65 C 149 F circuit respiratoire chauff max 30 W FONCTIONNEMENT Plage de pression 4 20 cmH O Plage d altitude D bits maximum R glage de pression de PPC cmH 0 Pression mesur e au niveau du raccord port cmH O D bit maximum au raccord du masque L min De 0 3000 m 0 a 9000 pieds Stabilit de la pression statique long terme Variation de pression de 0 05 a 0 18 cmH O mesur e au raccord du masque un r glage de pression de 10 cmH O Stabilit de la pression dynamique court terme R glage de pression de PPC cmH 0 Difference de pression au raccord
40. mmages mat riels r sultant d une utilisation du dispositif non conforme aux instructions d utilisation fournies e L appareil doit tre utilis uniquement avec les masques conformes la norme ISO 17510 2 les tuyaux et les tubulures recommand s par Fisher amp Paykel Healthcare ou par le prestataire de soins e Ne pas utiliser l appareil lorsque la temp rature ambiante d passe les 35 C 95 F cela pourrait augmenter la temp rature de l air et entrainer une irritation des voies respiratoires e Pour les r parations et l entretien consulter Fisher amp Paykel Healthcare AVERTISSEMENTS Pour viter un choc lectrique provenant de l appareil ne pas e Faire fonctionner l appareil si la prise ou le cordon d alimentation est endommag Faire fonctionner l appareil s il a t mis dans de l eau Brancher l appareil sur la prise d alimentation s il est mouill Nettoyer l appareil lorsqu il est branch la prise d alimentation Stocker ou utiliser l appareil dans un endroit o il peut basculer tomber ou tomber dans l eau Si de l eau a p n tr dans l appareil d brancher le cordon d alimentation et arr ter de l utiliser Demander conseil Fisher amp Paykel Healthcare Pour viter de suffoquer ou d inhaler un corps tranger e Ne jamais placer d objet dans les orifices du tube e S assurer que le filtre air est en place lors de l utilisation l appareil Pour assurer un traitement optimal ne pas
41. n chirurgie ou traumatisme cr niens r cents anomalies de la lame cribl e hypotension pathologique ou patients dont les voies respiratoires sup rieures sont shunt es PR CAUTIONS e l innocuit et l efficacit de la pression positive n ont pas t d termin es pour les patients pr sentant une insuffisance respiratoire ou une BPCO EFFETS IND SIRABLES e Des saignements de nez ou un inconfort des sinus ou des oreilles peuvent survenir avec l utilisation de la PPC En cas de questions sur le traitement contacter le m decin 3 DESCRIPTION DE L APPAREIL 3 1 Contenu de l emballage i Ulm d humidification 1 x ThermoSmart Circuit Chauffant 2 x Chambre 1 x Cordon d alimentation 1 x Entonnoir 1 x Filtre air de rechange 1 x SleepStyle 600 CPAP Series Accessoires 3 2 El ments importants de l appareil CORDON D ALIMENTATION a et RACCORD THERMOSMART CIRCUIT CHAUFFANT INTERRUPTEUR CONNECTEUR A MANCHON PRISE DE CONNECTION DE THERMOSMART CIRCUIT CHAUFFANT FILTRE A AIR PLAQUE CHAUFFANTE AFFICHAGE CHAMBRE D HUMIDIFCATION DISPOSITIF PROTECTEUR ENTONNOIR NIVEAU DE REMPLISSAGE D EAU vertical NIVEAU D EAU 3 3 Accessoires HC365 Chambre d humidification standard 900HC240 Filtre x2 HC360 Chambre d humidification dur e de vie prolong e 900HC604 Kit de nettoyage de la prise de connexion 900HC522 Le circuit respiratoire chauff ThermoSmart 900HC627 Coude
42. nly operate the device if it is connected to a PC via an isolated serial port adapter 900HC236 e To prevent airway irritation do not use the device when room temperature exceeds 95 F 35 C CONTRAINDICATIONS e Research indicates the following pre existing conditions may contraindicate the use of positive pressure for some patients pneumothorax bullous lung disease pneumocephalus cerebrospinal fluid leak recent cranial surgery or trauma abnormalities of the cribriform plate pathologically low blood pressure or in patients whose upper airways are bypassed PRECAUTIONS e The safety and effectiveness of positive pressure has not been established in patients with respiratory failure or COPD ADVERSE EFFECTS e Nosebleeds ear and sinus discomfort may occur from the use of positive pressure therapy Please contact your physician if you have any questions concerning your therapy 2 3 DESCRIPTION OF THE DEVICE 3 1 Package Contents i Ulm 1 x ThermoSmart 2 x Water Chamber 1 x Power Cord Heated Breathing Tube 1 x Funnel 1 x Spare Air Filter 1 x SleepStyle 600 CPAP Series Accessories 3 2 Important Parts of the Device POWER CORD wi CONNECTOR ON OFF BUTTON CONNECTOR WITH SLEEVE FILTER HOLDER ZA THERMOSMART HEATED BREATHING TUBE CONNECTION PORT AIR FILTER HEATERPLATE DISPLAY WATER CHAMBER FINGER GUARD FUNNEL WATER FILL LINE vertical WATER LEVEL LINE 3 3
43. ntes requisitos IEC 60601 1 UL60601 1 CSA C22 2 No 601 1 AS3200 1 0 EN60601 1 ISO 17510 1 El dispositivo cumple con los requisitos de compatibilidad electromagn tica de la norma IEC 60601 1 2 En ciertas circunstancias el dispositivo puede influir o puede recibir la influencia de equipos cercanos debido a los efectos de las interferencias electromagn ticas En este caso mueva el dispositivo o la ubicaci n del equipo que causa las interferencias o p ngase en contacto con su proveedor de cuidados de la salud El cuadro a continuaci n indica las principales diferencias en caracter sticas entre los productos de la serie SleepStyle 600 MODELO CPAP Totalmente Integrado Con Humidificaci n Calentada Control de Cumplimiento Pantalla y descarga Ajuste Autom tico de la Altitud Compensaci n de Fuga NOTE e Todos los modelos est n totalmente integrados con la Tecnolog a ThermoSmart e Algunos modelos no est n disponibles en todos los pa ses Fisher amp Paykel CE 0123 HEALTHCARE Manufacturer Mil Fisher amp Paykel Healthcare Ltd 15 Maurice Paykel Place East Tamaki Auckland 2013 PO Box 14 348 Panmure Auckland 1741 New Zealand Tel 64 9 574 0100 Fax 64 9 5740158 Email info fphcare co nz Web www fphcare com Australia Tel 61 3 9879 5022 Fax 61 3 9879 5232 Austria Tel 0800 29 31 23 Fax 0800 29 31 22 Benelux Tel 31 40 216 3555 Fax 31 40 216 3554 China Tel 86 20 3205 3486 Fax 86 2
44. on Effectuer un mauvais r glage de l altitude quelque soit le lieu peut engendrer des effets d l teres sur la pression d livr e 9 QUESTIONS FR QUEMMENT POS ES Dois je utiliser de l eau distill e avec mon appareil L utilisation d eau distill e maximisera la dur e de vie de la chambre d humidification L eau du robinet m me filtr e contient des min raux pouvant endommager la chambre d humidification formant un creux la base de celle ci Puis je utiliser mon appareil dans d autres pays Oui Utiliser simplement l adaptateur lectrique ad quat et l appareil s adaptera n importe quelle tension Remarque Lorsque vous transportez l appareil assurez vous que la chambre est vide La garantie ne couvre pas les dommages occasionn s par l eau Puis je utiliser un suppl ment d oxyg ne avec mon appareil Oui il est possible d administrer de l oxyg ne via le masque Mettez l appareil sous tension avant d ouvrir l oxyg ne V rifiez que la source d oxyg ne est ferm e avant de mettre l appareil hors tension afin d viter l accumulation d oxyg ne dans l appareil A quel moment dois je remplacer la chambre d humidification Remplacer la chambre si les parties en plastique se d colorent ou pr sentent des fissures ou si la base de la chambre est abim e Remarque si la chambre fuit remplacez la imm diatement Puis je utiliser mon appareil sans circuit chauffant Oui c est possible mais vous ne b n ficierez pas d
45. on professionnelle dans les laboratoires du sommeil Se r f rer la liste des diff rents produits de la gamme du SleepStyle serie dans la section Appendice de ce manuel 5 PR CAUTIONS LORS DE L UTILISATION D OXYG NE Si de l oxyg ne est n cessaire il est recommand que l alimentation d oxyg ne soit d livr e au masque Consulter les instructions sp cifiques sur le genre de masque utilis REMARQUE e Pour un d bit d oxyg ne fixe la concentration d oxyg ne inhal e varie en fonction des r glages de pression du profil de respiration du patient du masque utilis et du taux de fuite Avant d utiliser l oxyg ne avec l appareil se reporter aux avertissements du chapitre 2 6 NETTOYAGE amp ENTRETIEN NOTER l appareil doit tre nettoy de la mani re suivante 1 teindre l appareil et le d brancher de la prise de courant Attendre que l eau refroidisse puis retirer la chambre 2 Essuyer l ext rieur de l appareil avec un linge propre et humide sans tre mouill et un d tergent doux N utilisez pas de produits abrasifs ou de solvants risquant d endommager l appareil 3 JOURNALIER Nettoyer la chambre le circuit chauffant et le connecteur du circuit chauffant e D tacher le circuit de l appareil en soulevant le manchon vers le haut pour d bloquer le connecteur Retirer ensuite le connecteur e Nettoyer le circuit chauffant l eau savonneuse Rincer et suspendre le circuit en l air en s assurant que se
46. osici n e Sisiente que hay mucha humedad en el tubo o el aire parece muy caliente disminuya el intervalo de posici n e Sino logra el confort ptimo con este par metro puede realizar m s ajustes alterando el par metro clim tico ThermoSmart Par metro clim tico ThermoSmart este par metro proporciona m s opciones de ajuste mediante la optimizaci n de la humedad suministrada El ajuste se puede realizar de 1 a 3 con incrementos de 1 El dispositivo ha sido configurado por defecto en 2 que es adecuado para la mayor a de los pacientes Tenga en cuenta que si ajusta el par metro clim tico el par metro de humedad volver al par metro por defecto t e Para suministro oral de CPAP le recomendamos que fije el nivel clim tico ThermoSmart en 3 e Si siente que el intervalo de par metros que ofrece el par metro de humedad ThermoSmart es muy seco o muy frio aumente el intervalo de posici n del par metro de humedad ThermoSmart e Sisiente que el intervalo de par metros que ofrece el par metro de humedad ThermoSmart es muy caliente o muy h medo reduzca el intervalo de posici n del par metro de humedad ThermoSmart Se recomienda mantener el tubo de respiraci n calentada por encima de la ropa de cama para mantener unas condiciones ptimas de humidificaci n Para operar los par metros de humedad y clim ticos ThermoSmart vea la secci n 8 Controles y Pantalla de este manual 4 USO PARA EL
47. over over the serial port adaptor Other e Place the device on a level surface lower than head height to prevent water entering the tubing If water does enter the tubing drain excess condensate Water in the tubing may result in aspiration e The device is intended to be used with CPAP masks and connectors that have exhaust flow holes to allow continuous flow of air out of the mask When the device is turned on and operating properly new air flushes exhaled air out of the mask through the exhaust flow holes At low CPAP pressures and in the event of power failure or machine malfunction remove the mask immediately as flow through the mask may be insufficient to clear all exhaled gas and CO re breathing may occur which can be hazardous Failure to select the correct altitude level for any given location will have an adverse effect on delivered pressure e This device is not intended for life support Avoid unnecessary removal of the power cord from the rear of the device If removal is necessary then hold the connector and remove Avoid pulling on the power cord refer to Section 3 2 CAUTIONS To prevent water damage to your device e Remove the humidification chamber from the device before filling e Empty water from the chamber before transporting the device If the device is required to be handled with water in the chamber avoid tilting the device to prevent water entering its enclosure Other e To prevent damage to your PC o
48. po se adaptar autom ticamente a cualquier suministro de voltaje Nota Cuando mueva su equipo aseg rese de que la c mara de agua se encuentre vac a Las aver as de la m quina debidas a da os provocados por agua no est n cubiertas por la garant a Se puede utilizar ox geno complementario con el equipo S se puede administrar ox geno directamente a trav s de la mascarilla Encienda el equipo antes de abrir el paso del ox geno Aseg rese de que la fuente de ox geno est cerrada antes de apagar el equipo para evitar la acumulaci n de ox geno en la m quina Cu ndo se debe cambiar la c mara de agua Cambie la c mara si las paredes de pl stico de la c mara se agrietaran o perdieran color o si la base de la c mara se picara Nota Si se advirtiera la m s m nima fuga la c mara deber cambiarse inmediatamente Puedo utilizar mi equipo sin un tubo de respiraci n calentado S si puede No podr obtener el rendimiento ptimo de humedad que el equipo ofrece El aparato no presentar entonces el s mbolo de tubo de respiraci n calentado y no mostrar lo siguiente en la pantalla Qu ocurre con el dispositivo si se produce un fallo en el suministro el ctrico Retire la mascarilla de inmediato Al restablecerse el suministro el ctrico el dispositivo se reiniciar en el mismo modo de funcionamiento y con los mismos par metros que antes del fallo de suministro el ctrico Consulte la Secci n
49. s e Para evitar que se da e su ordenador utilice el dispositivo s lo si est conectado al ordenador a trav s de un adaptador de puerto serial aislado 900HC236 e Para evitar la irritaci n de las v as respiratorias no utilice el dispositivo si la temperatura ambiente sobrepasa los 35 C CONTRAINDICACIONES e La investigaci n indica que las siguientes condiciones preexistentes pueden contraindicar el uso de presi n positiva en algunos pacientes neumot rax enfermedad bulosa pulmonar neumoenc falo p rdida de l quido cerebroespinal cirug a o traumatismo craneal recientes anormalidades de la placa cribriforme presi n sangu nea patol gicamente baja o pacientes con desv o de las v as respiratorias superiores PRECAUCIONES e No se ha establecido que la presi n positiva sea segura y eficaz para los pacientes con insuficiencia respiratoria o EPOC EFECTOS NEGATIVOS e Debido al uso de la terapia de presi n positiva puede aparecer hemorragia nasal molestias en el o do y en el seno P ngase en contacto con su m dico si tiene cualquier pregunta sobre la terapia C 2 3 DESCRIPCI N DEL APARATO 3 1 Contenido del paquete i Ulm 1x Tubo de en 1 x cable el ctrico respiraci n calentado ThermoSmart 1 x embudo 1 x filtro de aire de repuesto 1 x CPAP Serie SleepStyle 600 Accesorios 3 2 Piezas importantes del equipo CABLE EL CTRICO S y CONECTOR TUBO DE RESPIRACION CALENTADO T
50. s extr mit s pointent vers le bas afin qu il s che compl tement Retirer la chambre en poussant la protection vers le bas et faire sortir la chambre Vider et jeter l eau usag e Nettoyer les chambres standard HC365 l eau savonneuse rincer et s cher Les chambres dur e de vie prolong e HC365 doivent tre d sassembl es avant nettoyage Pousser la base de la chambre comme indiqu sur la Figure 1 S assurer que la jupe la base n est pas l che ou endommag e Nettoyer le dessus et la base de la chambre avec un d tergent doux Rincer soigneusement et s cher Vous pouvez galement nettoyer cette chambre dans un lave vaisselle domestique e Essuyer l int rieur du connecteur du circuit chauff l aide d un chiffon l g rement humide propre et sans peluche 4 HEBDOMADAIRE Nettoyer la chambre e Nettoyer soigneusement la chambre en la faisant tremper 10 minutes dans une solution de vinaigre blanc et d eau 1 dose de vinaigre blanc pour 2 doses d eau et rincer soigneusement l eau distill e 5 ENTRETIEN e Replacer le filtre air lorsqu il se d colore de mani re significative au moins une fois tous les 3 mois ou apr s 1000 heures de fonctionnement Retirer tout d abord le support de filtre l arri re de l appareil comme indiqu sur la Figure 2 S assurer que la ligne noire verticale du nouveau filtre fait face l appareil et placer les deux dans l appareil e Remplacer la chambre si elle est fissur e d color
51. se haya enfriado y a continuaci n extraiga la c mara 2 Limpie la parte exterior del dispositivo con un trapo limpio h medo no mojado y detergente suave No use limpiadores abrasivos o disolventes ya que pueden da ar el dispositivo 3 DIARIAMENTE Limpie la c mara el tubo calentado y el puerto de conexi n del tubo calentado e Retire el tubo de respiraci n calentado del aparato tirando de la vaina protectora hacia arriba para desbloquear el conector Luego retire el conector e Enjuague el tubo de respiraci n calentado con agua y jab n y luego cu lguelo con sus extremos apuntando hacia el suelo para secar Retire la c mara presionando la protecci n de los dedos y sacando la c mara hacia arriba Vierta y deseche el agua restante Para c maras est ndar HC365 lave con agua jabonosa luego enjuague y seque La c mara larga vida HC360 requiere que se desmonte antes de lavarla Empuje hacia afuera la base de la parte superior de la c mara como se muestra en el Gr fico 1 Aseg rese de que el sello redondo en la base no est suelto o da ado Lave la parte superior y la base de la c mara en un detergente para lavar platos suave Enjuague a fondo y deje secar Esta c mara se puede limpiar tambi n en un lavavajillas dom stico e Limpie cuidadosamente el interior del puerto de conexi n del tubo calentado con un trapo h medo limpio que deje poca pelusa 4 SEMANALMENTE Limpie a fondo la c mara de agua e Deje remojar durante 10
52. symbol and show the following display What happens to my device during power failure Remove the mask immediately Upon restoration of the power supply the device will restart in the same operation mode with the same settings as before the power failure Refer to Section 2 for additional information 10 OPERATING CONDITIONS AMBIENT TEMPERATURE 41 95 F 5 35 C HUMIDITY 10 95 Relative Humidity RH ALTTUDE O 9000 ft 0 3000 m Above 1500 m 4500 ft the maximum operating pressure will be reduced 11 STORAGE AND TRANSPORT CONDITIONS The device should be stored and transported in environmental conditions of 14 to 140 F 10 to 60 C 12 TROUBLESHOOTING If you feel that your device is not operating correctly consult your healthcare provider Do not attempt to repair the device yourself 13 WARRANTY Please contact your Fisher amp Paykel Healthcare Provider regarding warranty 14 DEVICE AND CONSUMABLES DISPOSAL INSTRUCTIONS e Unit Disposal Instructions This unit contains electronics Please do not discard as regular rubbish Dispose according to local guidelines for disposing of electronics Place the mask breathing tube and water chamber in a rubbish bag at the end of use and discard with normal rubbish e Consumable Disposal Instructions 15 PRODUCT SPECIFICATIONS DIMENSIONS MS STANDARDS COMPLIANCE 273 mim x O mmx 175 mm Designed to conform to the WEIGHT 4 6 lbs 2 1
53. t modifi s les param tres d humidit retournent automatiquement leur valeur par d faut e est recommand de r gler la valeur des Conditions ambiantes ThermoSmart 3 pour les patients avec une interface buccale t e Si vous trouvez que les variations offertes par le r glage d humidit ThermoSmart produisent un air trop sec ou trop froid augmentez la valeur du r glage de condition ambiante e Si vous trouvez que les variations offertes par le r glage d humidit ThermoSmart produisent un air trop chaud ou trop humide diminuez la valeur du r glage de condition ambiante Il est recommand de placer le circuit chauffant au niveau de la t te de lit pour de meilleures performances d humidification Pour r gler l Humidit et Conditions ambiantes ThermoSmart consulter la rubrique 8 Contr les et Affichage de ce mode d emploi USAGE RECOMMAND l appareil a pour objectif le traitement du syndrome des apn es du sommeil SAS et est particuli rement recommand comme aide respiratoire de patients endormis La m thode consiste d livrer une Pression Positive Continue PPC afin de pr venir l obstruction des voies respiratoires L adjonction d un humidificateur respiratoire chauffant pr vient les effets dess chants et irritants des voies respiratoires couramment observ s lors de l utilisation d appareils PPC L appareil est destin aux adultes pour une utilisation domicile ainsi qu une utilisati
54. tion dans le masque peut s av rer insuffisante pour vacuer les gaz expir s et r inhaler du CO peut tre dangereux e Un mauvais r glage du niveau d altitude quel que soit l endroit aura un effet n faste sur la pression d livr e e Cet appareil n est pas destin la r animation e viter de d brancher inutilement le cordon d alimentation situ l arri re de l appareil Si c est n cessaire tenir la prise pour d brancher viter de tirer sur le cordon d alimentation se reporter au paragraphe 3 2 PR CAUTIONS Pour viter que l appareil ne soit endommag par de l eau e Retirer la chambre d humification du dispositif avant remplissage e Vider l eau de la chambre avant de transporter l appareil Si l appareil doit tre manipul avec de l eau dans la chambre ne pas incliner l appareil pour viter que de l eau ne p n tre a l int rieur Autre e Pour viter d endommager votre PC ne faire fonctionner l appareil que s il est connect au PC avec un adaptateur de port s rie isol 900HC236 e Pour viter toute irritation des voies respiratoires ne pas utiliser l appareil si la temp rature ambiante d passe 35 C 95 F CONTRE INDICATIONS e Les recherches indiquent que l utilisation de la pression positive peut tre d conseill e chez certains patients qui pr sentent les conditions suivantes pneumothorax troubles pulmonaires bulleux pneumoc phalie fuites de liquide c phalo rachidie
55. xtended life HC360 chamber requires disassembly before cleaning Push the base off the chamber top as shown in Fig 1 Ensure the round seal at the base is not loose or damaged Wash the chamber top and base in a mild dishwashing detergent Rinse thoroughly and dry This chamber may also be cleaned in a domestic dishwashing machine e Thoroughly wipe the inside of the heated breathing tube connection port with a clean damp low lint cloth WEEKLY Thoroughly clean the chamber e Soak the inside of the chamber for 10 minutes in a solution of one part white vinegar to two parts water and rinse well with distilled water MAINTENANCE e Replace the air filter when it becomes significantly discoloured at least once every three months or after 1000 hours machine run time To do this remove the filter holder from the back of the device as shown in Fig 2 Ensure the vertical black line of the new filter is facing towards the device and fit both back to the device e Replace the chamber if it is cracked discoloured or scratched e Replace the heated breathing tube after 4000 hours usage or once per year A damaged tube needs to be replaced immediately SETUP INSTRUCTIONS Remove your device from its packaging Place the device on a low shelf or on the floor beside your bed the unit needs to be placed below head height Remove water chamber from the packaging Remove the blue caps and discard them Fig 1 Fill the chamber up to the wat

Download Pdf Manuals

image

Related Search

Related Contents

1 - Sentry® Safe  Black & Decker WLL1B User's Manual  Voir la fiche technique  Motion detection in a video stream    Print version of this Book (PDF file)  fraguacret - Tecnoconcret  TPE Guide méthodologique  Gerätebeschreibung  5-in-1 Multi-Cooker Instruction Manual  

Copyright © All rights reserved.
Failed to retrieve file