1. INSDB G Meltric Corporation 4765 W Oakwood Park Drive Franklin WI 53132 Tel 800 433 7642 Fax 414 433 2701 e mail mailfdmeltric com A manufacturer of products using Marechal technology CORPORATION meltric com E GENERAL DB Decontactor Series products are designed to provide the safety and functionality of a switch with the convenience of a plug amp receptacle They can safely be used to make and break electrical connections even in overload situations and are an approved line of sight disconnect switch AW AR N N G There are inherent dangers associated with electrical products Failure to follow safety precautions can result in serious injury or death These instructions must be followed to ensure the safe and proper installation operation and maintenance of the Meltric devices Before installation disconnect all sources of power to the circuit to eliminate the risk of electrical shock E RATINGS DB Decontactors are UL 8 CSA listed as switch rated plugs and receptacles in accordance with UL Subject 2682 UL 1682 and CSA 22 2 No 182 1 DB Decontactors are listed as Branch Circuit Disconnect Switches and are also horsepower rated and listed as Motor Circuit Disconnect Switches The amperage voltage horsepower switch and environmental rat ings are indicated on the product labels All DB Decontactors are rated to make and withstand short circuit currents of 100 kA or more These r
2. SSEMEN Il existe des dangers inh rents My AVERTIS SEMENT aux produits lectriques Le non respect des r gles de s curit peut entra ner des blessures graves ou la mort Les pr sentes instructions doivent tre suivies pour assurer une installation une utilisation et un entretien ad quats et s curitaires Avant l installation d branchez toute source d alimentation du circuit afin d liminer les risques d lectrocution I CLASSIFICATION Les mod les DB Decontactor sont class s par UL et la CSA comme fiches et prises fonction d interrupteur sec tionneur conform ment aux normes UL Subject 2682 UL 1682 et CSA 22 2 n 182 1 Ils sont class s comme interrupteurs sectionneurs de circuit de d rivation et de circuit moteur et poss dent galement un classement horse power Lintensit la tension et la puissance HP nominales et la cote environnementale sont indiqu es sur les tiquettes de l appareil Tous les appareils DB Decontactor peuvent r sister aux courts circuits de 100 kA ou plus Les tensions sont indiqu es au tableau 1 selon le calibre de fusible Certains appareils DB sont quip s de contacts aux iliaires optionnels qui se connectent apres les contacts de phase mais qui se d connectent avant ces derniers Le calibre des contacts auxiliaires est indiqu au tableau 2 Tableau 1 Calibre des courants de court circuit produits et support s Calibre du fusible DB30 30A 100 kA a 600 V c a
3. www becma ch INSDB G Meltric Corporation 4765 W Oakwood Park Drive Franklin WI 53132 Tel 800 433 7642 Fax 414 433 2701 e mail mailfdmeltric com A manufacturer of products using Marechal technology m MELTRIC CORPORATION meltric com I GENERAL Los productos DB de la serie Decontactor est n dise ados para proveer la seguridad y funcionalidad de un interruptor con la conveniencia de un tomacorriente y clavija Pueden utilizarse para conectar y desconectar de manera segura conexiones el ctricas aun incluso en caso de una sobrecarga adem s de estar aprobadas como interruptor desconectador de L nea de Vista A ADVERTENCIA Hay peligros inherentes con los productos el ctricos El no siguir las precauciones de seguridad puede resultar en lesiones graves o muerte Seguir estas instrucciones para mantener una segura y apropiada instalaci n uso y mantenimiento de los productos Meltric Antes de instalar desconecte todas las fuentes al circuito para eliminar el riesgo de shock el ctrico Mi RANGOS Las tomacorrientes y clavijas de la serie Decontactor DB de Meltric est n listados como interruptor por UL amp CSA conforme a los incisos de las normas UL 2682 y CSA 22 2 182 1 Estos han sido certificados como Interruptores para Desconexi n de Circuitos Derivados est n certificados en caballos de potencia y listados como Interruptores para Desconexi n de Circuitos de Motores El
4. 60A 5 mm ou pointe de 3 16 po DB100 100A 4 0 6 mm ou pointe de 1 4 po Assemblage des prises mont es Ne serrez pas trop les vis des bornes et les A vis autotaraudeuses Serrez les vis au couple appropri pour assurer une bonne connexion Lorsqu une prise DB est raccord e a un boitier mural un panneau ou autre equipement orientez le voyant m canique de la prise vers le haut pour assurer un fonctionnement optimal Ins rez le cable ou les fils dans le bo tier mural et cou pez les a une longueur appropri e D nudez le cable de sa gaine et d nudez ensuite chaque fil sur la longueur indiqu e au tableau 4 avant d entortiller les brins de chaque conducteur MISE EN GARDE D vissez les bornes de raccordement de la prise juste assez pour permettre le passage des conducteurs Ins rez com pletement chaque conducteur dans la borne appropri e et resserrez les vis des bornes a la main aux couples indiqu s au tableau 5 Fixez la prise et le joint d tanch it a code de couleur au bo tier au moyen des attaches appropri es Fixez la fiche a l extr mit du cordon comme l indiquent les directives d assemblage en s rie ci dessus MISE EN GARDE Les poign es filet es de Meltric sont munies d un filetage conique On recommande d utiliser du ruban d tanch it pour maintenir tanch it a l eau de tous les joints et raccords NPT Assemblage des fiches c ble Poign e Prise Ecrou de comp
5. RK1 125A DB60 60A 100 kA a 600 V c a RK1 250A DB100 100A 100 kA a 600 V c a RK1 250A Calibre de fusible applicable jusqu a la tension indiqu e Les calibres sont tablis a partir de tests effectu s avec des fusi bles limiteurs de courant sans temporisation Ferraz Shawmut Les fusibles utilis s limitent le courant de 100 kA a 60 HP a 600 V 40 HP a 480 V 20 HP a 240 V et 208 V L appareil ne peut d passer 10 kA pour toutes les puissances HP ou le calibre de 100 kA ne s applique pas Tableau 2 Calibre des contacts auxiliaires M INSTALLATION Les appareils Decontactor doivent tre install s par un lectricien qualifi dans le respect de tous les codes de l lectricit locaux et nationaux Avant de commencer l installation assurez vous que l alimentation lectrique est coup e que le calibre des produits correspond a l utilisation pr vue et que les conducteurs satisfont aux normes des codes et qu ils ne d passent pas la capacit des bornes tableau 3 Tableau 3 Capacit des bornes1 AWG Mod le Contacts princ Aux Contacts oso soa a 8a 1a co A A a ps1oo ooa mo 20 14 1 Capacit indiqu e pour des fils de type THHN 2 Les contacts auxiliaires sont offerts en option sur certains produits seulement Remarques et pr cautions g n rales 1 Des vis autotaraudeuses sont fournies pour la pose de certains accessoires en polymere Un couple lev
6. a l aide d un poin on de 6 35 mm 1 4 po Quand la fiche et la prise sont connect es et que la bague est compl tement tourn e le trou n est plus obtur par la languette de cade nassage On peut alors ins rer un cadenas ou un verrou de s ret Trou de Arn cadenassage a NES NS I cadenassage Bague Cadenassage de la fiche et de la prise en position de repos circuit ouvert Lorsque la fiche est en position de repos ou d arr t vous pouvez aligner les trous de la bague et de la fiche Ins rez un cadenas ou un verrou au travers des deux trous pour cadenasser l appareil dans cette position I ENTRETIEN AV AVERTISSEM ENT Avant d inspecter de r parer ou se k d entretenir un appareil Meltric coupez l alimentation lectrique de la prise pour liminer les risques d lectrocution Les produits Meltric n cessitent peu d entretien Cependant il est recommand d effectuer p riodiquement les inspections suivantes e Assurez vous que les vis de montage sont bien serr es e Assurez vous que le poids du cable est support par le serre c ble et non par les bornes e V rifiez l tat et usure des joints IP Remplacez les au besoin e V rifiez la continuit lectrique du circuit de mise a la terre e Examinez les surfaces de contact pour vous assurer de leur propret et de l absence de piq res A l aide d un linge propre essuyez la poussi re et les corps trangers sur les contac
7. amperaje voltaje potencia en HP capaci dad interruptiva y protecci n envolvente se indican en las etiquetas del producto Todos los Decontactores DB est n clasificados para soportar y exceder corrientes de corto circuito de 100 kA o superiores Estos rangos se indica en la Tabla 1 Algunos de los dispositivos DB se proporcionan con la opci n de contactos auxiliares que se conectan despu s y desconectan antes de los contactos de fases Los ran gos de los contactos auxiliares se indican en la Tabla 2 Tabla 1 Rango de Soporte al Corto Circuito Rango del fusible DB30 30A 100kA 600VAC RKI 125A DB60 60A 100 kA 600 VAC RK1 250A DB100 100A 100 kA 600 VAC RK1 250A Los rangos aplican con fusibles hasta este rango en amperes Rangos se basan en pruebas realizadas con fusibles limitado res de corriente sin retraso de tiempo Ferraz Shawmut Los fusibles usados limita la certificacion de 100kA a 60hp 600VAC 40hp 480VAC 20hp 240VAC amp 208VAC El dispositivo esta certificado para 10kA para todos las certifica ciones en hp donde la certificaci n de 100kA no es aplicable Tabla 2 Rango de Contactos Auxiliares M INSTALACI N Los Decontactores deben ser instalados por electricistas calificados de acuerdo con todas las A normas de instalaciones el ctricas vigentes aplicables locales o federales Antes de iniciar verifique que el circuito no este energi zado que el rango del producto es el apr
8. in conjunction with products not bearing the Marechal technology trademark The use of Meltric products in conjunction with mating devices that are not marked with the Marechal nology trademark shall void all warranties on the product Meltric Corporation is an ISO 9001 certified com pany Its products are designed manufactured and rated in accordance with applicable UL CSA and IEC standards Meltric is also a member of BECMA the international Butt contact Electrical Connectors Manufacturers Association Like all members Meltric additionally designs and manufactures its products in accordance with BECMA standards established to ensure intermatablility with similarly rated products manufactured by other members INSDB G www becma ch CONSIGNES D UTIK f L gt gt Sf INSDB G Meltric Corporation 4765 W Oakwood Park Drive Franklin WI 53132 Tel 800 433 7642 Fax 414 433 2701 e mail mailfdmeltric com A manufacturer of products using Marechal technology meltric com M RENSEIGNEMENTS G N RAUX Les appareils DB de la gamme Decontactor poss dent les caract ristiques s curitaires et fonctionnelles d un interrupteur sectionneur et la commodit d une fiche et d une prise Ils peuvent tre utilis s en toute s curit pour tablir et couper une liaison lectrique m me en cas de surcharge et peuvent servir d interrupteurs sectionneurs approuv s install s la vue
9. integral multi layer bushing cord grips adjust the bushing diameter to fit the cable by removing inner sections of it as required Insert the bushing into the strain relief then insert the assembly into the handle and loosely install the compression nut Insert the cable through the handle the thin black drawplate gasket and finger drawplate if applicable and the color coded gasket Strip the cable sheath to provide a workable wire length being mindful that the sheath must extend into the handle to achieve a secure cord grip Then strip the individual wires to the lengths indicated in Table 4 and twist the strands of each conductor together Do not overtighten terminal or self tapping A screws Tighten screws to the proper torque to ensure a secure connection NOTICE Back out the terminal screws on the receptacle or inlet far enough but NOT completely to allow the conductors to pass insert the conductors fully into their respective terminals and tighten the terminal screws with the appropriate tool to the torque indicated in Table 5 Verify that the cable sheath extends beyond the strain relief and into the handle Assemble the receptacle or inlet the color coded gasket the finger drawplate and the thin black drawplate gasket to the handle with the four self tapping screws provided Adjust the cable location so that it will not be under tension inside the handle and tighten the compression nut to secure the cable Hole
10. n aplica al tomacorriente cuando la tapa est asegurada y el aro de cierre ha girado completamente hacia la derecha AVISO Medidas adecuadas deben tomarse para mantener protecci n contra el ingreso de agua en los accesorios NPT conduit en la manija de la clavija o en la caja de conexiones Se recomienda el uso de cinta para sellar Accesorios de Bloqueo Todos los tomacorrientes y clavijas DB se proporcionan con dispositivos de bloqueo Bloqueo de Clavija Para evitar que la clavija se conecte con el tomacorri ente instale un candado o bloqueo de seguridad en el orificio proporcionado Orificio para bloqueo Bloqueo del Tomacorriente Inserte la tapa y gire completamente el aro de cierre hacia la derecha Un candado o bloqueo de seguridad pueden ser insertados por el orificio en el aro de cierre Bloqueando el Tomacorriente y Clavija en Posici n de Cerrada Verifica que el tomacorriente no est energizado Antes de abrir el orificio tipo knock out localizado en el aro de cierre Para bloquear el tomacorriente y clavija en la posici n cerrada se debe de abrir un orificio tipo knock out con un punz n de Y localizado en el aro de cierre Cuando el tomacorriente y clavija est n conectados y el aro de cierre est en la posici n de IP67 el orificio de bloqueo pasara sobre la ventanilla y el candado o bloqueo de seguridad pueden ser instalados Orificios de An de bloqueo n
11. peut tre n cessaire pour les enfoncer mais prenez soin de ne pas trop les serrer sur le plastique 2 Diff rents types de poign es et diff rentes brides de cordon peuvent tre utilis s Les pr sentes consignes sont bas es sur l utilisation de poi gn es dont les embouts s adaptent a plusieurs grosseurs de c ble 3 Les longueurs de fil d nud sont indiqu es au tableau 4 La longueur de c ble a d nuder d pend de l utilisation pr vue Pour fixer un cable a une poign e assurez vous que la gaine du cable d passe a l int rieur de la poign e pour que le cordon offre une bonne prise A cable I r Tableau 4 Longueur de fil d nuder Dimensions A Le Phase et neutre A la masse aux 2 Mod le e po mm DB100 100A 13 8 4 Les bornes de raccordement sont dot es de ressorts pour emp cher la formation d un jeu caus e par le d placement des brins des c bles les vibrations et les cycles thermiques MISE EN GARDE D vissez partiellement les bornes de raccordement de la prise juste assez pour permettre le passage des conducteurs Ins rez compl tement chaque conducteur dans la borne appropri e Ne serrez pas trop les vis des bornes Le tableau 5 indique les outils utiliser et les couples de serrage appropri s Tableau 5 Couple de serrage des bornes de raccordement g Couple Mod le Tournevis Tournevis plat DB30 30A 3 mm ou pointe de 1 8 po DB60
12. riente hasta que llegue al tope entonces gire la clavija hacia la derecha en este punto la clavija est en una posici n de descanso y el circuito sigue abierto Empuje la clavija hacia el tomacorriente hasta que el aro de cierre mantenga la clavija en su lugar Figura 2 La conexi n el ctrica se ha logrado cuando se indica por el color rojo en la ventana indicadora de cierre Protecci n contra el ingreso de agua IP67 se completa cuando se gira completamente el aro de cierre hacia la derecha hasta que el accesorio can dado pase completamente por arriba de la ventana indicadora de cierre Desconexi n Para desconectar gire el aro de cierre completamente hacia la izquierda Esto abrir el circuito y expulsara la clavija directamente hacia a la posici n de descanso Los contactos de la clavija est n desenergizados en este punto Para quitar la clavija gire la clavija hacia la izquierda aproximadamente 10 hasta que se pueda retirar del tomacorriente Figura 3 Monte la tapa al tomacorriente y gire el aro de cierre hacia la derecha para proporcionar una protecci n IP67 al tomacorriente Figura 4 La clavija debe ser devuelta a su posi ci n de descanso antes de hacer otra conexi n Protecci n Contra el Ingreso de Agua El rango de protecci n solo es alcanzado cuando el tomacorriente y clavija est n conectados y el aro de cierre ha girado completamente hacia la derecha Tambi
13. the lid is inserted and the locking ring is fully rotated in the clockwise direction NOTICE Proper steps must be taken to maintain watertightness at NPT fittings on the plug handles or at the junction box Use of a sealer tape is recommended Lockout Provisions All DB plugs and receptacles are provided with lockout provisions Plug Lockout To prevent the DB plug from being inserted into any DB receptacle place a padlock or a safety lockout through the hole provided Lockout Hole Receptacle Lockout Insert the lid and fully rotate the locking ring clock wise A padlock or safety lockout can then be inserted in the hole on the locking ring Locking Plug and Receptacle in Closed Position Deenergize electrical power to the receptacle prior to punching out the knockout hole on the receptacle locking ring To lock the plug and receptacle in the closed position a knock out hole located on the receptacle locking ring must first be opened with the help of a 1 4 punch When the plug and receptacle are engaged and the locking ring is fully rotated then the lockout hole will have cleared the window shroud and a padlock or safety lockout can be inserted Lockout ZA RR Holes ys Y a Q Locking Ring ad Locking Plug and Receptacle in the Open or Parked Position When the plug is in the rest or off position the lockout holes on the locking ring and plug can be aligned Insert a safety lockout device through both hole
14. A DB60 60A 1 DB100 100A Do not overtighten terminal or self tapping screws Tighten screws to the proper torque to ensure a secure connection In applications where DB receptacles or inlets are mounted to wall boxes panels or other equipment optimal operation is achieved when the device is 4 installed with the viewing window at the top Insert the cable or wires through the wall box and cut to allow adequate length strip the cable sheath as desired strip the individual wires to the lengths indicated in Table 4 and twist the strands of each conductor together NOTICE Back out the terminal screws on the receptacle or inlet far enough but NOT completely to allow the conductors to pass insert the conductors fully into their respective ter minals and hand tighten the terminal screws to the torque indicated in Table 5 Assemble the receptacle or inlet and the color cod ed gasket to the box using the appropriate hardware Assemble the mating plug or receptacle to the cord end as indicated in the assembly instructions above for in line connections NOTICE Meltric threaded handles come with tapered style threads The use of fitting seal tape is recommended to maintain watertightness of all NPT fittings and joints Assembly for Plugs or Connectors Gasket Bushing Handle Receptacle Compression or Inlet Nut When assembling male inlets or female recept acles to handles with
15. B en instalaciones especiales se deber n de utilizar sellos a prueba de agua en las cabezas de los cuatro tornillos de montaje y deben ser retenidos por una rondana de presi n y un tuerca en el interior de la caja de conexiones o el panel Alternativamente 4 barrenos ciegos pueden ser taladrados y o roscados para insertar los tornillos de montaje siempre y cuando la profundi dad de los barrenos es suficiente para asegurar la sufici ente compresi n del empaque Mi OPERACI N Para mantener la operaci n segura y confiable de los tomacorrientes y clavijas Meltric se deber n de utilizar de acuerdo con sus capacidades Solo pueden utilizarse en conjunto con tomacorrientes y clavijas Meltric y otro fabricante autorizado de los pro ductos que ostenten la marca registrada Marechal Meltric dise a sus tomacorrientes y clavijas con posiciones de bloqueo diferentes de tal manera que solo las clavijas y tomacorrientes que tienen las mismas configuraciones de contactos y voltajes pueden acoplarse entre s Conexi n Primero gire el aro de cierre hacia la izquierda La tapa del tomacorriente puede ser removida Para su conveniencia la tapa se mantiene amarrada al tomacorriente con un alambre Para conectar la clavija al tomacorriente alinee la flecha en el envolvente de la clavija con el lado izquierdo de la ventana indicadora de cierre en el tomacorriente Figura 1 Empuje la clavija parcialmente al tomacor
16. ESPONSABILIDAD DEL FABRICANTE La responsabilidad de Meltric esta limitada estrictamente a la reparaci n y o reemplazo de cualquier producto que no cumpla con la garant a especificada en el contrato de compra Meltric no puede ser responsabilizado por fal las da o a consecuencia de la perdida de producci n o cualquier perdida financiera en la que incurra el cliente Meltric Corporation no puede ser responsabilizado cuando sus productos son utilizados en conjunto con otra marca que no tenga la marca registrada Marechal El uso de dispositivos acoplables que no tengan la marca registrada Marechal invalidara toda garant a en el producto Meltric Corporation es una compa a certificada ISO 9001 Sus productos est n dise ados manufacturados y con rangos de acuerdo con las normas aplicables UL CSA y IEC Meltric es tambi n un miembro de BECMA Butt contact Electrical Conectors Manufacturers Association Asociaci n Internacional de Fabricantes de Conexiones Punto a Punto Como todos los miem bros de la asociaci n Meltric dise a y manufactura sus productos de acuerdo con los est ndares BECMA para que tengan intercambiabilidad con productos similares manufacturados por otros miembros www becma ch INSDB G
17. General Notes amp Precautions 1 Self tapping screws are provided for use with some polymeric accessories High torque may be required to drive them in Once they are seated care should be taken in order to avoid over tightening them against the plastic material 2 Various handles and cord grip options may be used These instructions are based on handles provided with integral multi layer bushing cord grips 3 Wire strip lengths are indicated in Table 4 Strip lengths for cable sheathing will depend on the specific application When used with handles the cable sheathing should extend into the handle to ensure secure cord gripping P or cable Table 4 Wire Strip Length Dimensions A Device mm Inches mm 4 Wiring terminals are spring assisted to prevent loosening due to wire strand settlement vibration and thermal cycling NOTICE Back out the termi nal screws on the receptacle or inlet far enough but not completely to allow the conductors to pass Then insert the conductors fully into the proper terminal The terminal screws should not be over tightened Appropriate tools and tighten ing torques are indicated in Table 5 Table 5 Terminal Screw Tightening Torques Device Required Screwdriver in Ibs Flathead type DB30 30A 13 3 mm ou pointe de 1 8 po 13 DB60 60A 5 mm ou pointe de 3 16 po DB100 100A 6 mm ou pointe de 1 4 po Assembly for Mounted Receptacles or Inlets DB30 30
18. Pattern for Custom Mounting In applications where custom mounting to a panel or box is being performed the clearance and mounting holes should be drilled as indicated in the following diagram and Table 6 lt B gt Table 6 Custom Mounting Dimensions NOTICE In order to maintain the IP protection provided by DB models in custom installations watertight seals should be used under the heads of the four mounting bolts and they must be retained by a lock washer and nut on the inside of the box or panel Alternatively four blind holes may be drilled and threaded to accommodate the mounting screws provided that the hole depth is sufficient to achieve adequate gasket compression I OPERATION To ensure safe and reliable operation A Meltric plugs and receptacles must be used in accordance with their assigned ratings Meltric plugs and receptacles can only be used in conjunction with mating receptacles or plugs manu factured by Meltric or another licensed producer of products bearing the Marechal technology trademark Meltric plugs amp receptacles are designed with different keying arrangements so that only plugs and receptacles with compatible contact configurations and electrical ratings will mate with each other Connection First remove the lid on the receptacle by turning the locking ring fully counterclockwise The lid can then be removed For convenience it remains attached to the receptacle
19. atings are indicated in Table 1 along with the fusing upon which they are based Some DB devices are provided with optional auxiliary contacts that make after and break before the phase contacts The ratings for auxiliary contacts are shown in Table 2 Table 1 Short Circit Make amp Withstand Ratings Rating Fuse DB30 30A 100kA 600 VAC RK1 125A DB60 60A 100kA 600 VAC RK1 250A DB100 100A 100 kA 600 VAC RK1 250A Rating applies with fusing up to this amperage Ratings are based on tests performed with Ferraz Shawmut non time delay current limiting fuses The fusing used limits the 100kA rating to 60hp 600V 40hp 480V 20hp 240V amp 208V The device is rated for 10kA for all hp ratings where the 100kA rating does not apply Table 2 Auxiliary Contact Ratings 600VAC M INSTALLATION Decontactors should be installed by qualified electricians in accordance with all applicable local and national electrical codes Before starting verify that the power is off that the product ratings are appropriate for the application and that the conductors meet code requirements and are within the capacities of the terminals noted in Table 3 Table 3 Wiring Terminal Capacity in AWG Device Minimum Maximum Maximum DB30 30A 14 8 14 DB60 60A 8 3 14 DB100 100A 1 Capacity is based on THHN wire sizes 2 Auxiliary contacts are optional and may not be on all products
20. avija lo suficiente pero no completamente para permitir que el conductor pase inserte el conductor completamente en su respectiva terminal y apriete manualmente el tornillo al torque indicado en la Tabla 5 Ensamble el tomacorriente o clavija y el empaque codificado por color a la caja con la torniller a adec uada Ensamble la clavija o tomacorriente al cable como se indican en las instrucciones de ensamble descritas a continuaci n AVISO Se recomienda el uso de cintas selladoras para las cuerdas para impedir el ingreso de agua en las uniones y juntas del tubo conduit NPT Ensamble de las Clavijas o Conectores Empaque Multicapa Empaque Codificado por Relevador 1 de Esfuerzo Manija Tomacorriente o Clavija Tuerca de Compresi n Cuando se ensamblen clavijas o tomacorrientes a las manijas con empaque multicapa ajuste el di metro del empaque multicapa removiendo cada una de las mismas seg n se requiera inserte el empaque en el relevador de esfuerzo luego inserte el ensamble en la empu adura enseguida libremente inserte la tuerca de compresi n Inserte el cable en la manija el empaque negro delgado la placa de cierre con los dedos si es necesario y el empaque codificado por color Remueva el aislamiento del cable para proveer un rea de trabajo adecuada tomando en cuenta que se deber de introducir en la manija lo suficiente como para proveer un agarre seguro del cable Entonces remueva
21. by a wire To insert the plug into a receptacle the arrow on the plug casing is aligned with the left end of the viewing window on the receptacle Figure 1 Push the plug partially into the receptacle until it hits a stop then rotate slightly clockwise The plug is now in the rest position with circuit open Push the plug straight into the receptacle until it is held in place by the locking ring Figure 2 The electrical connection is now made as indicated by the red color in the viewing window IP67 watertightness is achieved by fully rotating the locking ring in the clockwise direction until the protruding lockout tab completely clears the window shroud Disconnection To break the connection turn the locking ring fully counterclockwise This will break the circuit and eject the plug straight out to the rest or off position The plug contacts are deenergized at this point To remove the plug rotate it counterclockwise about 10 until it can be withdrawn from the receptacle Figure 3 Insert the lid and rotate the locking ring fully clockwise to provide IP67 protection to the receptacle Figure 4 To attempt another engage ment after disconnection the plug must be returned to its rest position Achieving Ratings amp Watertightness Rated ingress protection is achieved when the plug and receptacle are mated and the locking ring is fully rotated in the clockwise direction It can also be achieved by the receptacle when
22. el aislamiento de cada uno de los conductores la distancia que se indica en la Tabla 4 y tuerza los hilos de cada conductor para que se unan No sobre apriete las terminales o los tornillos A autorroscantes Apriete los tornillos a su torque apropiado para mantener una conexi n segura AVISO Afloje los tornillos de las terminales en la tomacorriente o clavija lo suficiente pero no comple tamente para permitir que pase el conductor inserte completamente el conductor en las terminales apropia das y apriete los tornillos con la herramienta apropiada al torque indicado en la Tabla 5 Verifique que el aislamiento del cable se extienda m s all del relevador de esfuerzo y dentro de la manija Ensamble el tomacorriente o clavija el empaque cod ificado por color la placa de cierre con los dedos y el empaque negro delgado a la manija con los 4 tornillos autorroscantes suministrados Ajuste el cable para que no est bajo tensi n dentro de la manija y apriete la tuer ca de compresi n para asegurar el cable Dimensiones de Barrenos para Montaje Especial En aplicaciones en donde se requiere montaje especial a un panel o caja est siendo realizado los barrenos y la distancia entre ellos deber n de hacerse de acuerdo con el diagrama y la tabla siguiente 4 x 0 196 9 or 5mm Tabla 6 Dimensiones de Barrenos para Montaje Especial Modelo DB30 AVISO Para mantener la protecci n IP prove da por los modelos D
23. l tement la bague en sens horaire pour assurer la protection IP67 fig 4 Pour r tablir le courant apr s une d connexion il faut d abord remettre la fiche en position de repos Classification et tanch it Lorsque la fiche et la prise sont raccord es l indice de protection est obtenu une fois la bague compl tement tourn e en sens horaire Lorsque la fiche est seule lin dice de protection est obtenu une fois le couvercle ferm et la bague completement tourn e en sens horaire MISE EN GARDE II faut prendre des mesures appro pri es pour assurer l tanch it a l eau des joints NPT sur les poign es de fiche ou une boite de jonction L utilisation d un ruban d tanch it est recommand e Cadenassage Toutes les fiches et prises DB sont munies de dispositifs de cadenassage Cadenassage de la fiche Pour viter d ins rer une fiche DB dans une prise placez un cadenas ou un verrou de s ret dans le trou pr vu cet effet Trou de cadenassage Cadenassage de la prise Fermez le couvercle et tournez compl tement la bague en sens horaire Ins rez un cadenas ou un verrou de s ret dans le trou de la bague Cadenassage de la fiche et de la prise en circuit ferm Coupez l alimentation de la fiche puis percez le trou enfon able qui se trouve en saillie sur la bague de la prise Pour verrouiller la fiche et la prise en position ferm e un trou enfoncable sur la prise doit tre ouvert
24. ont offertes avec plusieurs configurations de contacts de mani re ce que seules les prises et fiches dont les contacts et les calibres sont com patibles puissent tre connect es Connexion Pour lib rer le couvercle de la prise tournez compl tement la bague en sens antihoraire Vous pouvez enlever le cou vercle qui reste commod ment attach la prise par un fil Pour ins rer la fiche dans la prise alignez la fleche des sin e sur le bo tier de la fiche avec le c t gauche du voyant de la prise comme Pillustre la figure 1 Poussez la fiche jusqu en but e puis tournez la l gerement en sens horaire La fiche est en position de repos circuit ouvert Enfoncez la fiche en ligne droite jusqu ce qu elle soit main tenue en place par la bague fig 2 Le courant lectrique est tabli comme Il indique le voyant rouge Pour assurer une tanch it a l eau d indice IP67 tournez compl tement la bague en sens horaire jusqu a ce que la fen tre ne soit plus bloqu e par la languette de cadenassage D connexion Pour couper le courant tournez compl tement la bague en sens antihoraire Le circuit sera ainsi ouvert et la fiche sera ject e en position de repos A cette tape les contacts de la fiche sont hors tension Pour retirer la fiche tournez la dans le sens antihoraire d environ 10 jusqu a ce qu elle se d gage de la prise comme montr a la figure 3 Remettez le couvercle et tournez comp
25. opiado para la aplicaci n que los conductores cumplan con la normativ idad vigente y que se encuentran dentro del a capacidad de las terminales que se mencionan en la Tabla 3 Tabla 3 Capacidad de Alambrado1 AWG Contactos Principales Contactos Aux Dispositivo DB100 100A 1 0 1La Capacidad se basa en las dimensiones del cable THHN 2 Los contactos auxiliares son opcionales y pueden no incluirse en todos los productos Notas Precauciones Generales 1 Se proporcionan tornillos autorroscantes para ser utilizados con algunos componentes polim ricos puede requerirse de un gran torque para atornillar los una vez hecho esto evite apretarlos demasiado contra el material pl stico 2 Pueden utilizarse varias empu aduras y conectores tipo glandula para el conductor estas instruciones est n basadas en empu aduras que utilizan un conector tipo glandula para el cable con un empaque multicapa 3 El largo del cable requerido sin aislamiento para introducir en las terminales se indica en la Tabla 4 este largo depender de la aplicaci n espec fica cuando se utiliza con manijas el largo del conduc tor sin aislamiento deber de llegar al fondo de la terminal para asegurar un sujeci n segura del cable A RU cable Tabla 4 Largo del Cable sin Aislamiento Dimensiones A Pulgadas mm Pulgadas mm 4 Las terminales para de cableado est n asistidas por un resorte arillo de seguridad para evitar q
26. que de levage et son mince joint d tanch it noir sur la poi gn e a l aide des quatre vis autotaraudeuses fournies R glez la position du cable de mani re a ce qu il ne soit pas tendu dans la poign e puis serrez l crou de com pression pour fixer le c ble en place Dimensions des trous pour montage sur mesure Dans le cas d un montage sur mesure dans un panneau ou un boitier les d gagements et les trous de fixation doivent respecter les dimensions indiqu es dans le gra phique et le tableau 6 ci dessous 4 x 0 196 po n 9 ou 5 mm Modele MISE EN GARDE Pour conserver la classification IP des mod les DB lors d un montage sur mesure vous devez utiliser des joints tanches a l eau sous les t tes des quatre boulons de montage et retenir ces derniers a l aide d une rondelle de blocage et d un crou a lin t rieur du bo tier ou derri re le panneau Vous pouvez galement percer et fileter quatre trous borgnes pour y ins rer les vis de montage pourvu que les trous soient suffisamment profonds pour permettre une compression ad quate des joints UTILISATION Pour assurer une utilisation s curitaire et fiable les A fiches et prises Meltric doivent tre utilis es confor m ment a leur classification respective Elles peuvent uniquement tre utilis es avec des fiches ou des prises fabriqu es par Meltric ou un autre fabricant de produits portant la marque Marect Les fiches et prises Meltric s
27. ression Lorsque vous fixez une fiche ou une prise a une poign e dont l embout s adapte a plusieurs grosseurs de cable ajustez le diametre de l embout a celui du cable en retirant des rondelles int rieures au besoin Ins rez embout dans le serre c ble puis ins rez l assemblage dans la poign e pour ensuite installer crou de compression sans le serrer Faites passer le cable dans la poign e dans la plaque de levage et son mince joint d tanch it noir si l appareil en est quip et dans le joint d tanch it a code de couleur Retirez suffisamment de gaine pour disposer d une longueur facilitant le travail en tenant compte que la gaine doit entrer dans la poign e pour assurer une prise solide D nudez ensuite chaque fil en respectant les longueurs indiqu es au tableau 4 puis entortillez ensemble les brins de chaque conducteur Ne serrez pas trop les vis des bornes et les A vis autotaraudeuses Serrez les vis au couple appropri pour assurer une bonne connexion MISE EN GARDE D vissez juste assez les bornes de raccordement de la prise pour permettre le passage des conducteurs Ins rez completement chaque conducteur dans la borne appropri e et resserrez les bornes avec Poutil appropri en respectant les couples indiqu s au tableau 5 Assurez vous que la gaine du cable d passe le serre cable et p n tre dans la poign e Installez la prise le joint d tanch it a code de couleur ainsi que la pla
28. s to lock the unit in the parked position M MAINTENANCE Before inspecting repairing or A WARNING maintaining Meltric products disconnect electrical power to the receptacle to eliminate the risk of electrical shock Meltric products require little on going maintenance However it is a good practice to periodically perform the following general inspections e Check the mounting screws for tightness e Verify that the weight of the cable is supported by the strain relief mechanism and not by the terminal connections e Check the IP gaskets for wear and resiliency Replace as required e Verify the electrical continuity of the ground circuit e Check the contact surfaces for cleanliness and pitting Use a clean cloth to rub off deposits of dust or similar foreign materials on the contacts and the plug interiors Sprays should not be used as they tend to collect dirt If any significant pitting of the contacts or other serious damage is observed the device should be replaced MANUFACTURER S RESPONSIBILITY Meltric s responsibility is strictly limited to the repair or replacement of any product that does not conform to the warranty specified in the purchase contract Meltric shall not be liable for any penalties or consequential damages associated with the loss of production work profit or any financial loss incurred by the customer Meltric Corporation shall not be held liable when its products are used
29. ts et les parois internes de la fiche N utilisez pas de produits en vaporisateur car ils ont tendance a ramasser la salet En cas de piq res importantes sur les contacts ou d autres dommages graves remplacez l appareil RESPONSABILITE DU FABRICANT La responsabilit de Meltric se limite strictement a la r paration ou au remplacement de tout produit non conforme a la garantie pr cis e dans le contrat d achat Meltric ne peut tre tenue responsable des p nalit s ou des dommages indirects d coulant d une perte de production de travail de b n fices ou de toute perte financi re subie par le client Meltric Corporation ne peut tre tenue responsable lorsque ses produits sont utilis s avec d autres produits qui ne portent pas la marque de commerce MarechalW Le branchement de produits Meltric dans des produits qui ne portent pas la marque de commerce Marechal a pour effet d annuler toute garantie La soci t Meltric poss de la certification ISO 9007 Ses produits sont con us fabriqu s et class s selon les normes UL CSA et IEC applicables Meltric est galement membre de l Association des fabricants de connecteurs lectriques a contacts en bout BECMA Comme tous les membres de cette association inter nationale Meltric congoit et fabrique ses produits selon les normes BECMA qui garantissent la compatibilit de ses produits avec ceux de classes similaires fabriqu s par les autres membres INSDB G
30. u x Q A O Aro de cierre 7 Bloqueando la Tomacorriente y la Clavija en su Posici n Desenergizado o Estacionaria Cuando la clavija est en su posici n estacionaria o desenergizado los orificios de bloqueo en el aro de cierre y la clavija pueden alinearse Use un dispositivo seguridad para el bloqueo pas ndolo por los orificios para cerrar la unidad en la posici n estacionaria o desenergizado E MANTENIMIENTO A ADVERTENCIA Antes de inspeccionar reparar o mantener los productos Meltric desconecte la alimentaci n al tomacorriente para elimi nar el riesgo de shock el ctrico Los productos Meltric requieren de muy poco manten imiento de cualquier manera es muy recomendable que se realicen las siguientes pr cticas de inspecci n general e Revise el apriete de los tornillos de montaje e Verifique que el peso del cable este soportado en el relevador de esfuerzos y no en las terminales de conexi n e Revise el desgaste y ajuste del empaque IP Inter c mbielo seg n se requiera e Verifique la continuidad el ctrica del circuito de tierra e Revise la limpieza y desgaste de la superficie de los contactos Dep sitos de polvo o materiales ajenos similares pueden ser limpiados con un trapo limpio Aerosoles no deben ser utilizados por que atraen suciedad Si un desgaste severo en los contactos o cualquier otro da o serio en el dispositivo son encontrados el dispositivo deber de ser reemplazado R
31. ue se aflojen debido a vibraci n asentamiento o ciclo t rmico AVISO Afloje los tonillos de las terminales en el tomacorriente o clavija lo suficiente pero no completamente para permitir que pase el conductor Inserte completamente el conductor en las termina les apropiadas No sobre apriete los tornillos de las terminales Herramienta y torque apropiado est n indicados en la Tabla 5 Tabla 5 Torques para los Tornillo de las Terminales Pulg lbs N m Desarmador Requerido o Llave Allen DB30 30A 3 mm or 1 8 pulg tip de precision DB60 60A 5 mm or 3 16 pulg tip de precision DB100 100A 6 mm or 1 4pulg tip de precision Ensamble para la instalacion de las Tomacorrientes o Clavijas No sobre apriete las terminales o los tornillos autorroscantes Apriete los tornillos a su torque apropiado para mantener una conexi n segura En aplicaciones donde los tomacorrientes o clavijas DB son instaladas en cajas de conexiones para montaje en pared paneles u otro equipo la optima operaci n se logra cuando la ventana indicadora de cierre se instala en la parte superior Inserte el cable o alambre a trav s de la caja de conex iones y corte permitiendo un largo adecuado elimine el aislamiento tanto como sea deseado quite el forro de los conductores al largo indicado en la Tabla 4 y tuerza las puntas de cada conductor para unirlas AVISO Afloje el tornillo de las terminales en la tomacorriente o cl