Home

DigiOx - Graham Field

image

Contents

1. along bottom of screen as shown in Figure 9 e Press the Power Display Button once more the screen will now show pulse as a hollow wave form bar graph along bottom of screen as shown in Figure 10 f Press the Power Display Button once more the screen will return to the original screen as shown in Figure 5 on previous page Figure 10 SYMBOL KEY Warning See operation manual The pulse oxygen saturation KO Pulse rate beats per minute NON Low battery voltage X Not for continuous monitoring Spo2 Manufactured for GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 2009 GF Health Products Inc Made in China tel 770 368 4700 fax 770 368 2386 GRAHAM FIELD www grahamfield com JOHN BUNN DigiOx Oximetro de Uso Dactilar Manual de Operacion Importante No debe operar el John Bunn DigiOx Oximetro sin leer y entender este manual Guarde este manual para uso en el futuro Info La m s reciente versi n de este manual podr ser encontrado en www grahamtield com JB02008 INS LAB RevB14 A AVISOS Guarde al oximetro lejos de polvo vibraci n sustancias corrosivas materiales explosivos temperaturas altas y humedad Si el oximetro se moja por favor de parar de usarlo Cuando se mueve de un ambiente fri a un ambiente caliente y con humedad por favor de no usarlo inmediatamente Cuando el aparato se cambia de un ambiente fri a uno caliente o h medo permita
2. s la pantalla se volviera a la pantalla original como en la Figura 5 en la p gina anterior Figura 10 10 S MBOLOS E E SS did MON Voltaje bajo de las bater as X No es apto para monitoreo continuo al sp02 paciente Fabricado para GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 O 2009 GF Health Products Inc Fabricado en China tel 770 368 4700 fax 770 368 2386 GRAHAM FIELD www grahamfield com
3. CUBIERTA O EMPLEADO O CONTRATISTA INDEPENDIENTE SALARIOS PAGOS Y BENEFICIOS Esta garant a le da derechos legales espec ficos Puede tener derechos adicionales que var an estado por estado GF Health Products Inc no es responsable por errores tipogr ficos Para obtener la informaci n m s actualizada y vigente relativa a los envases garant as productos y especificaciones incluyendo la versi n m s actualizada de estas instrucciones por favor visite nuestro sitio web en www grahamfield com Graham Field y John Bunn son marcas registradas de GF Health Products Inc 19 El ox metro es dise ado para medidas r pidas No es apto para monitoreo continuo por largos periodos de tiempo al paciente NO DEBE aplicar el sensor al mismo dedo por m s de dos horas Si los resultados son anormales favor de cambiar la posici n del sensor El ox metro es utilizado como uno de los criterios para la evaluaci n del paciente Debe ser usado en conjunto con se ales cl nicas y s ntomas Est dise ado como un aparato para medici n no para tratamiento Campos el ctricas y magn tico son capaces de interferir con los resultados correctos del oximetro Por esta raz n asegure que todos los aparatos externos operados en la vecindad del oximetro cumplen con los requisitos de EMC Celulares equipo de radiograf a y aparatos de MRI pueden interferir porque emiten niveles altos de radiaci n electromagn ticos Este aparato cum
4. Problemas Continuadas Problema Razon Posible Soluci n Las bater as est n Cambie las bater as bajas Las bater as no Reposicione las est n puestas bater as de nuevo correctamente El aparato no se prende Llame a su distribuidor de GF Health Products Inc El aparato fallo El aparato Normal se apaga de repente El aparato se apaga autom ticamente 8 segundos despu s de sacar el dedo Las bater as se Cambie las bater as han gastado La pantalla Malfuncionamiento Llame a su distribuidor muestra del aparato de GF Health Products Error3 Inc Error4 Error6 o Error 14 DE COMERCIALIZACION O IDONEIDAD PARA UN PROPOSITO PARTICULAR SI CUALQUIER MODELO O MUESTRA FUE MOSTRADO AL CLIENTE COMO MODELO O MUESTRA FUE UTILIZADO UNICAMENTE PARA ILUSTRAR EL TIPO GENERAL Y CALIDAD DEL PRODUCTO Y NO REPRESENTA QUE EL NECESARIAMENTE ESTARA CONFORME AL MODELO O MUESTRA EN TODOS LOS ASPECTOS LA RESPONSABILIDAD TOTAL DE GF PARA CUALQUIER PRODUCTO O SERVICIO PROPORCIONADO SE LIMITAAL COSTO DEL PRODUCTO QUE DIO LUGAR A LA RECLAMACI N EN NINGUN CASO YA SEA POR CONTRATO INDEMNIZACI N GARANT A NEGLIGENCIA ESTRICTA RESPONSABILIDAD O CUALQUIER OTRA FORMA SE GF SER N RESPONSABLES POR DANOS DIRECTOS INDIRECTOS INCIDENTALES EJEMPLARES O INDIRECTOS INCLUYENDO PERO NO LIMITADO A DANOS POR PERDIDA DE BENEFICIOS O INGRESOS PERDIDA DE USO TIEMPO DE INACTIVIDAD
5. debe ser notificado de cualquier reclamaci n de garant a dentro del per odo de garant a aplicable Llame 678 291 3207 o por fax 770 368 2386 o por email a cs grahamfield com Falta de seguir las instrucciones espec ficas resultar en rechazo de la reclamaci n de garant a Garant a completa Recurso exclusivo y da os conse cuentes ESTA GARANTIA ES UNICA GARANTIA DE GF Y EN LUGAR DE CUALQUIER OTRA GARANTIA EXPRESA O IMPLICITA GF NO OFRECE GARANT AS IMPLICITAS DE NINGUN TIPO INCLUIDAS LAS GARANTIAS 18 Info Proporciona recomendaciones para la aplicaci n y otra informaci n til para as egurar que obtengas lo m s que puedes del producto A ADVERTENCIAS Importante Lee y entienda este manual antes de usar el oximetro No debe usar este aparato sin instrucciones provistas por un Profesional del Cuido de Salud Si el oximetro no es operado correctamente heridas a la persona y o da o al oximetro puede resultar Si los componentes est n da ados o si le faltan llame a su distribuidor inmediatamente NO DEBE usar piezas sustitutas Es necesario inspeccionar el aparato antes de uso para asegurar que no hay da o visible que puede afectar al paciente o la seguridad del usuario o confiabilidad de medida A partir de entonces debe inspeccionar el aparato por lo menos una vez a la semana GF Health Products Inc no asume ninguna responsabilidad de da o o lesi n causado por instalaci n ensamblaje o uso i
6. off if no finger is sensed for 8 seconds If the finger is removed and the Power Display Button is pressed the oximeter will remain on and change screens but will display FINGER OUT ACCESSORIES INCLUDED 1 One lanyard 2 Two AAA alkaline batteries 3 One operation manual REPAIR MAINTENANCE AND DISPOSAL Z WARNING DO NOT open the oximeter housing It contains no serviceable parts Service must be performed by trained authorized personnel only Otherwise device failure and health hazard may occur Maintenance In order to ensure the oximeter s longevity and continued dependable operation please observe the following maintenance recommendations 11 TECHNICAL SPECIFICATIONS Display screen Organic LED Display Power supply Two 1 5V AAA alkaline batteries requirement SpO Parameter Measuring range 0 100 Specifications Accuracy 70 100 3 lt 70 no definition Measuring range 30 235 bpm Accuracy 30 99bpm 2 bpm 100 235 bpm 2 Pulse Rate Parameter Specifications Environment Operation 41 F 104 F 5 C 40 C 15 80 RH Storage 4 F 158 F 20 C 70 C lt 93 RH Net weight with 2 oz 50g batteries Dimensions L x 2 28 x 1 26 x 1 34 58 mm x 32 mm W x H x 34 mm CONTENTS INTRODUCTION citas iacici ni a cai 3 INTENDED USE soscionticinsansniaaracacals 3 CONTRAINDICATIONS ccssececsteteeesseeeseseeeseaes 3 IMPORTANT SAFETY GUIDE
7. una situaci n de peligro o una pr ctica insegura que si no es evitado puede resultar en herida personal leve A AVISO Indica una situaci n de peligro o una pr ctica insegura que si no es evitado puede resultar en da o al producto o propiedad autom ticamente en 8 segundos cuando no est en uso El ox metro provee aproximadamente 30 horas de uso usando bater as alcalinas Nombre y Modelo Nombre John Bunn DigiOx Ox metro de Uso Dactilar Modelo JB02008 INSTALACION DE LAS BATERIAS 1 Refiere a la Figura 3 Inserta dos AAA bater as en el compartimiento correctamente en su direcci n correcta 2 Coloque el protector A AVISO Asegurase instalar las bater as correctamente Instalaci n incorrecta puede hacer que el aparato no funcione INSTRUCCIONES DE OPERACION Info Limpie el dedo de la prueba con el alcohol isopropilico antes y despu s de cada medida Asegure que el dedo est seco antes de insertarlo en el ox metro No debe hacer temblar su dedo cuando est s usando el aparato Evite poner el aparato en el mismo brazo donde tiene el medidor de presi n o cuando se est haciendo una infusi n venosa Figura 3 instalaci n de las bater as Destrucci n No debe tratar este aparato o sus bater as como residuos de dom sticos colleci n separado es necesario DETECTANDO PROBLEMAS El SpO y El dedo no Coloque el dedo Frecuencia est puesto correctamente y trato de Pulso correct
8. BILITY OR FITNESS FOR A PARTICULAR 18 Info Provides application recommendations or other useful information to ensure that you get the most from your product Z WARNINGS Important Read and understand this manual before using the oximeter Do not use this device without proper instruction from a Healthcare Professional If the oximeter is not properly operated personal injury and or damage to the oximeter could result If components are damaged or missing contact your dealer immediately DO NOT use substitute parts Inspect the device before use to ensure that there is no visible damage that may affect patient or user s safety or measurement performance Thereafter inspect the device at least once a week GF Health Products Inc assumes no responsibility for any damage or injury caused by improper installation or use of this product DO NOT open the oximeter housing It contains no serviceable parts Service must be performed by trained authorized personnel only Otherwise device failure and health hazard may occur EXPLOSION HAZARD Do not use the oximeter in the presence of flammable anesthetics explosive substances vapors or liquids Use only parts and accessories specified in this manual 4 Ensure that no obstruction contamination scar tissue fingernail polish acrylic fingernail etc exists at the site where the sensor ts placed such obstruction could affect the signal received by the sensor and re
9. HE MODEL OR SAMPLE IN ALL RESPECTS GF S TOTAL LIABILITY FOR ANY PRODUCT OR SERVICE PROVIDED IS LIMITED TO THE COST OF THE PRODUCT GIVING RISE TO THE CLAIM IN NO EVENT WHETHER IN CONTRACT INDEMNITY WARRANTY NEGLIGENCE STRICT LIABILITY OR OTHERWISE WILL GF BE LIABLE FOR ANY DIRECT SPECIAL INDIRECT INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF PROFITS OR INCOME LOSS OF USE DOWNTIME COVER OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS This warranty gives you specific legal rights You may have additional rights which vary from state to state GF Health Products Inc is not responsible for typographical errors All illustrations specifications packaging and warranties contained in this literature are based on the latest product information available at the time of printing The most current product information including the most current version of these instructions can be found online at www grahamfield com Graham Field and John Bunn are registered trademarks of GF Health Products Inc 2009 GF Health Products Inc Atlanta GA 30360 770 368 4700 19 The oximeter is designed for real time and rapid measurement It is not suitable for long time continuous patient monitoring DO NOT apply the sensor to the same finger for more than two hours If any readings are found to be abnormal please change the position of the sensor The oximeter i
10. JOHN BUNN DigiOx Finger Pulse Oximeter Operation Manual Important Do not operate the John Bunn DigiOx Finger Pulse Oximeter without first reading and understanding this manual Save this manual for future use Info The most current version of this manual can be found online at www grahamfield com JB02008 INS LAB RevB14 A NOTICES Keep the oximeter away from dust vibration corrosive substances explosive materials high temperature and moisture If the oximeter gets wet stop operation immediately and do not resume operation until it is dry When it is carried from a cold environment to a warm and or humid environment allow it to warm to room temperature before using it DO NOT use sharp objects to press the front panel button DO NOT sterilize this device Do not subject this device to irradiation steam ethylene oxide high temperature or immersion in liquid Refer to the Repair and Maintenance Cleaning and Disinfection section of this manual for instructions for cleaning and disinfection 6 6 To change the oximeter s display screen brightness press the Power Display Button for more than one second There are 10 brightness levels and the level from BR 1 to BR 10 will show on the screen during brightness adjustment The default is level four Keep the Power Display Button depressed for as long as it takes to cycle to the desired brightness level 7 The oximeter will automatically turn
11. LINES PLEASE READ BEFORE USE iscsissccocncccnsccteasesscesnsteianioceanss 3 OVERVIEW camisas 7 APPERRANGE sacacasa 7 FEATURE Suscisunionioacistriaalde cacas 7 NAME AND MODEL ciccdaniaa nani 8 BATTERY INSTALLATION nasses 8 OPERATION INSTRUCTIONS cooccccooccosconrosnonacanaos 8 ACCESSORIES INCLUDED lt lt w w 11 REPAIR MAINTENANCE AND DISPOSAL 11 MAINTENANCE cisiorarosiio ansias 11 CLEANING AND DISINFECTION 12 DISPOSAL comunas 13 TROUBLESHOOTING ociicico nicas 13 SYMBOL KEY nsin aan 15 TECHNICAL SPECIFICATIONS cccstesteseseeesesees 16 LIMITED WARRANTY sui ccicici ciniaic nicinica ia 18 MANUAL DE OPERACI N ESPA OL 21 2 OVERVIEW Appearance display screen battery cover a 5 ad e rubber cushion Figure 1 Figure 2 The DigiOx Finger Pulse Oximeter is shown above Features The John Bunn DigiOx Finger Pulse Oximeter provides a simple way to spot check patients by combining the sensor and monitor into one integrated compact easy to use device with single button operation The oximeter can accurately measure oxygen saturation and pulse rate When a finger is inserted into the sensor s rubber cushion and the Power Display Button is pressed to turn the oximeter on then the SpO value and pulse rate value display on the screen The oximeter features a bright color LED screen with adjusta
12. a es ajustable La pantalla es de direcci n m ltiple para que el usuario pueda leer los resultados de cualquier ngulo El ox metro tiene un indicador de voltaje bajo El ox metro se apagara 7 A Cambie las baterias cuando el indicador del voltaje bajo que se ve en la pantalla Limpie la superficie del aparato antes de uso Limpie el aparato con la gasa suave y saturarlo con la soluci n de 70 isopropilico alcohol primero d jalo que se seque Repitalo si es necesario Saque las bater as del oximetro si no va usar el aparato por un periodo de tiempo largo Ambiente AVISO Humedad puede reducir o da ar la vida del aparato Operaci n 41 F 104 F 5 C 40 C 15 80 RH Almacenaje 4 F 158 F 20 C 70 C lt 93 RH Limpiar y Desinfectar 1 No debe sumergir este aparato en l quidos Limpia solamente con la t cnica de limpiar superficie Debe usar la gasa suave y saturarlo con la soluci n de 70 isoprop lico alcohol 2 Limpie con un pa o suave y limpio saturado en agua limpia S calo con un pa o seco y limpio ZN ADVERTENCIA No use el sensor si est da ado A AVISO No debe esterilizar este aparado No debe sujetar este aparado a la irradiaci n al vapor al xido de etileno a la temperatura alta o a la inmersi n en l quido Especificaciones T cnicas Continuadas El tipo de protecci n contra descarga el ctrica Equipo con motor interior El grado de pro
13. amente en de nuevo no son el aparato estables El dedo est temblando o el paciente se est moviendo Asegure que el paciente se quede inm vil El valor de SpO del paciente es demasiado bajo medir ZN Media de nuevo si no tiene xito sin embargo el aparato esta funcionando correctamente p ngase en contacto con a un profesional m dico inmediatamente Hay luz ambiental Reduzca la luz excesiva ambiental GARANTIA LIMITADA Ambito de Garant a GF Health Products Inc GF garant a al comprador original el Cliente solamente que va reemplazar o reparar componentes a la decisi n solo de GF cuales son defectos en material o calidad utilizados normalmente durante un per odo de reparaci n de un a o despu s de la fecha de compra a menos que haya una fecha de caducidad en el componente en cuyo caso la garant a expirar en la anterior del per odo de garant a o la fecha de caducidad La garant a no se extiende a los componentes no durables y no fuerza laboral o el costo de transporte Esta garant a limitada no es transferible Todas garant as son condicionales por el uso apropiado de producto estrictamente en acuerdo con las instrucciones aplicables de GF incluyendo uso apropiado y mantenimiento La garant a ser nula si el defecto es causado por cualquier otra raz n no relacionada con defectos en los materiales o mano de obra Obteniendo Servicio de Garantia Equipo de servicio al cliente de GF
14. ble brightness and multi directional displays that enable the user to read results from any angle The oximeter features a low voltage 7 Change the batteries when the low voltage indicator displays Clean the surface of the device before using Wipe the device with a clean soft cloth saturated with a solution of 70 isopropyl alcohol then let it air dry or wipe it dry Repeat as necessary Take out the batteries if the oximeter will not be used for a long period of time Environment NOTICE Operation 41 F 104 F Humidity may shorten 5 C 40 C 15 80 RH the life of the device or even damage it Storage 4 F 158 F 20 C 70 C lt 93 RH Cleaning and Disinfection 1 Do not immerse the device in liquid Clean the device only by using a surface clean technique Wipe with a clean soft cloth saturated with a solution of 70 isopropyl alcohol 2 Wipe with a clean soft cloth saturated with clean water and air dry or dry with a clean soft cloth A WARNING Do not use the sensor if it is damaged A NOTICE Do not sterilize this device Do not subject this device to irradiation steam ethylene oxide high temperature or immersion in liquid TECHNICAL SPECIFICATIONS continued Classification The type of protection against electric shock Internally powered equipment The degree of protection against electric shock Type BF applied part The degree of protection against harmful ingress
15. mpropio de este aparato NO DEBE abrir la carcasa del oximetro No contiene partes servible Servicio debe ser hecho por solamente por un ingeniero de servicios cualificado Los usuarios no son permitidos a darles mantenimiento ellos mismos Fallo del aparato y peligro puede ocurrir PELIGRO DE EXPLOSION No debe usar el oximetro en la presencia de un ambiente con gas inflamable como agentes anest sicos substancias explosivas vapores o l quidos flamables Use solamente partes y accesorios especificados en este manual 4 No permita que ning n obstrucci n contaminaci n cicatriz esmalte unas acr licas etc est en el sitio donde est colocado el sensor Estas obstrucciones pueden afectar la se al recibidos por el sensor y puede resultar en una medida incorrecta Ejercicio vigoroso y interferencia de un aparato electro quir rgico pueden afectar la precisi n de la medida 1 Abra el aparato como se ve _ a en la Figura 4 M J 2 Inserte su dedo en el coj n de goma asegurase que su dedo est en la posici n correcta 3 Presione el Bot n del Prender Apagar y Mostrar 4 La pantalla le ense ar los datos como se ve en la Figura 5 El usuario puede obtener la informaci n directamente de la pantalla despu s de que se Figura 5 establece el valor 5 Cuando la pantalla se ve como en la Figura 5 presione el Bot n de Mostrar para cambiar la pantalla Figura 4 operaci n 198 75 0 Detectando
16. nd provides approximately 30 hours of use with the use of alkaline batteries Name and Model Name John Bunn DigiOx Finger Pulse Oximeter Model JB02008 BATTERY INSTALLATION 1 Refer to Figure 3 insert two AAA batteries oriented as shown into the battery compartment 2 Replace the cover Info Ensure the batteries are correctly installed Incorrect installation will prevent the device from operating OPERATION INSTRUCTIONS Info Clean the test finger with isopropyl alcohol before and after each measurement Ensure that the finger is dry before being inserted into the oximeter Do not shake the finger keep finger motionless during oximeter use Avoid placing the device on a limb which is wrapped with a cuff for blood pressure measurement or undergoing venous infusion Figure 3 battery installation 8 Disposal Do not treat this device or its batteries as household waste Separate collection is required TROUBLESHOOTING Finger Reposition finger incorrectly correctly and try again positioned in device Problem SpO and Pulse Rate display unstable or hard to see Finger is shaking or patient is moving Ensure patient remains immobile Patient s SpO value is too low to measure Z Remeasure if unsuccessful yet device is functioning correctly contact a medical professional immediately Excessive Reduce ambient light ambient light LIMITED WARRANTY SCOPE OF WARRANTY GF Health P
17. of liquids Ordinary equipment without protection against ingress of water Electro Magnetic Compatibility Group Class B INTRODUCTION Please read and understand all instructions before using the John Bunn DigiOx Finger Pulse Oximeter JB02008 Intended use The John Bunn DigiOx Finger Pulse Oximeter is used to measure oxygen saturation SpO and pulse rate in home or clinical settings It is designed for adult and pediatric patients Contraindications ZN WARNING The oximeter is not intended for continuous patient monitoring DO NOT use the oximeter while patient is undergoing MRI or CT scanning Important Safety Guidelines Please Read Before Use The safety statements presented in this chapter refer to the basic safety information that the operator of the John Bunn DigiOx Finger Pulse Oximeter shall pay attention to and abide by There are additional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations Z WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious injury Z CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in minor personal injury A NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage 3 indicator powers off automatically in eight seconds when not in use a
18. ongevidad y operaci n continua segura del ox metro por favor observe las siguientes recomendaciones para mantenimiento 11 ESPECIFICACIONES T CNICAS Modo de Mostrar Pantalla de LED org nico Requisito de Dos 1 5V AAA bater as alcalinas suministro el ctrico Especificaciones Rango de Medida 0 100 Par metro de SpO Presi n 70 100 3 lt 70 ninguna definici n Especificaciones de Frecuencia de Pulso Rango de Medida 30 235 bpm latidos por minuto Presi n 30 99 bpm 2 bpm 100 235 bpm 2 Dimensiones L x 2 28 x 1 26 x 1 34 58 mm x 32 mm WxH x 34 mm Ambiente Operaci n 41 F 104 F 5 C 40 C 15 80 RH Almacenaje 4 F 158 F 20 C 70 C lt 93 RH 2 onzas 50g con baterias CONTENIDOS INTRODUCCI N cccccooco PE E 3 USO ENTENDIDO DEL OXIMETRO sssssesssesssseees 3 CONTRAINDICACIONES sssssssssesssssecssesssstessseesseeeees 3 DIRECTIVAS IMPORTANTES DE SEGURIDAD POR FAVOR DE LEER ANTES DE USO 3 GENERALIDADES c sssessssssssssscssesssesesssssseessesssstessstessaeen 7 APARIENCIA oa tai 7 CARACTER STICAS s ssssssosecssessssecstecssesssstessseesseeeees 7 NOMBRE Y MODELO sessssssssssssssessstsssstsssstsssstesseeen 8 INSTALACI N DE LAS BATERIAS c ssssssssessssessteessees 8 INSTRUCCIONES DE OPERACI N 0 scsssssssssesssesssseesssees 8 ACCESORIOS INCLUIDOS ccsssssssssstsssssesssss
19. ple con IEC60601 1 2 NO DEBE ser puesto en un edema o tejido tierno La luz la luz infrarrojo es invisible emitido por el aparato le puede hacer da o a los ojos as que no debe fijarse en la luz NO DEBE fijarse directamente a la luz Este aparato debe estar guardado fuera del alcance de ni os Aviso para los clientes de California Proposici n 65 de California ADVERTENCIA Este producto contiene una sustancia qu mica conocida en el estado de California por causar c ncer y da os reproductivos o del desarrollo 5 a Presione el Bot n del Prender Apagar y Mostrar una vez m s la pantalla se voltear 180 grados y mostrar como se ve en la Figura 6 b Apret el Bot n de Mostrar una vez m s la pantalla se cambiara a la Figura 7 c Presione el Bot n del Prender Apagar y Mostrar una vez m s la pantalla se voltear 180 grados y muestra como se ve en la Figura 8 d Presione el Bot n del Prender Apagar y Mostrar una vez m s la pantalla se voltear 90 grados y mostrar tambi n el pulso como gr fico de barra llenado de la forma de onda a lo largo de la parte inferior de la pantalla como se ve en la Figura 9 e Presione el Bot n del Prender Apagar y Mostrar una vez m s la pantalla ahora mostrar tambi n el pulso como gr fico de barra hueco de la forma de onda a lo largo de la parte inferior de la pantalla como se ve en la Figura 10 f Presione el Bot n del Prender Apagar y Mostrar una vez m
20. que se caliente a la temperatura del cuarto antes de usarlo NO DEBE apretar el bot n al frente con objetos afilados NO DEBE esterilizar este aparado NO DEBE sujetar este aparado a la irradiaci n al vapor al xido de etileno a la temperatura alta o a la inmersi n en l quido Refiere a la secci n de Reparaci n y Mantenimiento Limpiando y Desinfectando de este manual para instrucciones para limpiar y desinfectar 6 6 Para cambiar el brillo de la pantalla presione el Bot n del Prender Apagar y Mostrar para m s de un segundo Hay 10 niveles del brillo y el nivel del BR 1 al BR 10 mostrar en la pantalla durante el ajuste del brillo El valor predeterminado es el nivel 4 Mantenga el Bot n del Prender Apagar y Mostrar presionado por el tiempo que sea necesario para el ciclo con al nivel de brillo deseado 7 El ox metro se apagar autom ticamente si no se detecta el dedo durante 8 segundos Si se quita el dedo y se presiona el Bot n del Prender Apagar y Mostrar el ox metro quedar orientado y cambiar la pantalla pero mostrar FINGER OUT ACCESORIOS INCLUIDOS 1 Cord n 2 AAA Bater as alcalinas 3 Un Manual de Operaci n REPARACI N Y MANTENIMIENTO Advertencia NO DEBE abrir la carcasa del oximetro No contiene partes servibles Servicio debe ser hecho solamente por personal autorizado Si no falla del aparato y da o a la salud puede ocurrir Mantenimiento Para asegurar la l
21. roducts Inc GF warrants to the original purchaser Customer only that it will replace or repair components at GF s sole discretion that are defective in material or workmanship under normal use for a period of one year after the purchase date unless there is an expiration date on the component in which case the warranty shall expire on the earlier of the warranty period or the expiration date The warranty does not extend to non durable parts and does not include labor or costs of shipping This limited warranty is not transferable All warranties are conditioned upon the proper use of the product strictly in accordance with good commercial practice and applicable GF instructions and manuals including proper use and maintenance The warranty is void if the defect is caused by any other reason not related to defects in materials or workmanship OBTAINING WARRANTY SERVICE GF s customer service team must be notified of any warranty claim within the applicable warranty period Call 678 291 3207 or fax 770 368 2386 or e mail cs grahamfield com Failure to follow the specific directions provided by the GF customer service team will result in denial of the warranty claim ENTIRE WARRANTY EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER THIS WARRANTY IS GF S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED GF MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTA
22. s intended only as an adjunct in patient assessment It must be used in conjunction with clinical signs and symptoms It is intended as a measuring not a treatment device Magnetic and electrical fields are capable of interfering with the proper performance of the oximeter For this reason ensure that all external devices operated in the vicinity of the oximeter comply with the relevant EMC requirements Mobile phones X ray equipment and or MRI devices are a possible source of interference as they may emit high levels of electromagnetic radiation This device complies with IEC60601 1 2 DO NOT clip this device on edema or tender tissue The infrared light emitted from the device it is invisible is harmful to the eyes DO NOT stare into the light Keep this device out of the reach of children Notice for California Customers California Proposition 65 WARNING This product contains a chemical known to the State of California to cause cancer and reproductive or developmental harm 5 a Press the Power Display Button once more the screen will rotate 180 and display as shown in Figure 6 b Press the Power Display Button once more the screen will rotate 90 and display as shown in Figure 7 c Press the Power Display Button once more the screen will rotate 180 and display as shown in Figure 8 d Press the Power Display Button once more the screen will rotate 90 and also show pulse as a filled wave form bar graph
23. ssssesseees 11 REPARACI N Y MANTENIMIENTO cconcconocionocioocionnocoss 11 MANTENIMIENTO csscsesssssessssessssssseessssessueessteessess 11 LIMPIAR Y DESINFECTAR ssssssssssssssssesesssesssssssee 12 DESTRUCCI N cccoccconcconocinnccinncninonionncnnnnnnno ronca 13 DETECTANDO PROBLEMAG sessssssssssssssessstssssteesseesees 13 S MBOLOS 0 sssesssssssssecssesssseessecssucesseessscessueesseessatessseeeses 15 ESPECIFICACIONES TECNICAS ssssssescssesssstessseeses 16 GARANT A LIMITADA s sscsssssssssessssessssssssscsstsssstessseesees 18 2 GENERALIDADES Apariencia pantalla de mostrar cubierto de la bater a bot n de E prender apagar y mostrar M cojin de goma Figura 1 Figura 2 El DigiOx Oximetro se demuestra arriba Caracteristicas Este John Bunn DigiOx Oximetro de uso Dactilar provee un m todo simple para chequear a los pacientes combinando un sensor y monitor en un aparato integrado y compacto que es f cil de usar y que tiene operaci n de un bot n El John Bunn DigiOx Ox metro de uso Dactilar puede ser usado para medir el valor de la saturaci n de ox geno SpO y el valor de frecuencia de pulso Poniendo su dedo en el sensor y apretando el Bot n de Prender el valor de SpO y de frecuencia de pulso se vera en la pantalla El ox metro tiene una pantalla de LED con color brillante que da m s colores vibrantes y tiene una vida de operaci n mas larga El brillo de la pantall
24. sult in an incorrect measurement Vigorous exercise and electrosurgical device interference may affect the measuring accuracy 1 Open the clip as shown in Figure 4 1 2 Insert finger nail up into the clip s rubber cushion ensure the finger is correctly positioned and then gently clip the finger 3 Press the Power Display Button to turn the oximeter on 0 4 The screen will then display the Figure 4 operation data as shown in Figure 5 After the values become stable the user can read the information on the display screen 5 When the screen displays as shown in Figure 5 pressing the Power Display Button will change the screen s orientation Figure 5 Troubleshooting continued The device Replace batteries low does not turn on Batteries Reinstall batteries incorrectly correctly installed The device has Contact your GF Health malfunctioned Products Inc distributor The device powers off automatically 8 seconds after finger is removed Batteries are Replace batteries almost drained Device Contact your GF Health malfunction Products Inc distributor The device turns off suddenly Screen displays Error3 Error4 Error6 or Error 14 PURPOSE IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER SUCH MODEL OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL TYPE AND QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT WOULD NECESSARILY CONFORM TO T
25. tecci n contra descarga el ctrica Parte aplicado de Tipo BF Clasificaci n El grado de protecci n contra un inmersi n de l quidos da inos Equipo ordinario sin protecci n contra inmersi n de agua Compatibilidad Electromagn tico Grupo Clase B INTRODUCCION Por favor de leer y entender las instrucciones antes de usar el John Bunn DigiOx Ox metro de uso Dactilar JB02008 Guarde estas instrucciones para uso en el futuro Uso Entendido del Oximetro El John Bunn DigiOx Ox metro es entendido para medir la saturaci n de ox geno SpO y la frecuencia de pulso en escenarios de casa y cl nicas Es dise ado para pacientes adultos y pedi tricos Contraindicaciones Z ADVERTENCIA El ox metro no es entendido para monitoreo continuo al paciente NO DEBE usar el oximetro cuando el paciente est debajo de un MRI o exploraci n de CT DIRECTIVAS IMPORTANTES DE SEGURIDAD por favor de LEER ANTES DE USO Las declaraciones de seguridad presentado en este capitulo refieren a la informaci n de seguridad b sica que el operador del John Bunn DigiOx Ox metro de uso Dactilar debe ponerle atenci n y seguirlo Hay declaraciones de seguridad adicionales en otros cap tulos o secciones cuales pueden ser lo mismo o similar a lo siguiente o especifico a la operaci n Z ADVERTENCIA Indica una situaci n de peligro o una pr ctica insegura que si no es evitado puede resultar en muerte o heridas serias ZN PRECAUCI N Indica

Download Pdf Manuals

image

Related Search

Related Contents

Monitoring and Control Solution - Worcester Polytechnic Institute  リリース詳細  Sega Genesis II Service Manual    co2 aiRSoFt / cal. 6 mm BB  National Adult Clozapine Titration Chart User Guide  Palsonic CD6990DM3UC User's Manual  note to installer: this manual should be left with the  CESAR – LCPC - cours archives  QUICKIN User Manual  