1. 1EC61010 1 co KN 8052 ae 600V Digital multimeter Multimetro digital Herramientas para siempre TABLE OF CONTENT Safety information 1 Safety symbols 1 Maintenance 1 During use 2 General description 2 Front panel 3 4 Specifications 4 General 4 7 Operating instructions 8 10 Battery amp fuse replacement 11 Accessories 11 1 SAFETY INFORMATION This multimeter has been designed according to IEC61010 1 concerning electronic measuring instruments with an overvoltage category CATII and pollution 2 Follow all safety and operation instructions to ensure that the meter is used safely and is kept in good operating condition Full compliance with safety standards can be guaranteed only with test leads supplied If necessary they must be replaced with the type specified in this manual SAFETY SYMBOLS AN Important safety information refer to the operating manual Dangerous voltage may be present X Anti garbage a Double insulation Protection class II Fuse must be replaced with rating specified in the manual MAINTENANCE Before opening the case always disconnect test leads from all energized circuits For continue protection against fire replace fuse only with the specified voltage and current ratings 250mA 250V Quick Acting 10A 250V Quick Acting Never use the meter unless the back cover is in place and fastened compl
2. Resolution Accuracy 200mV 100uV 0 5 of rdg 2 digits 2V 1mV 0 5 of rdg 2 digits 20V 10mV 0 5 of rdg 2 digits 200V 100mV 0 5 of rdg 2 digits 600V 1V 0 8 of rdg 2 digits Overload Protection 250V rms For 200mV range and 600V dc or rms ac for other ranges DC CURRENT Range Resolution Accuracy 200uA 0 1uA 1 of 2 digits 2mA 1uA 1 of 2 digits 20mA 104A 1 of rdg 2 digits 200 100uA 1 5 of rdg 2 digits 10A 10mA 3 of rdg 2 digits Overload Protection F 250mA 250V fuse 10A 250V fuse 5 KNOVA VOLTAGE Resolution Accuracy 200V 100mV 1 2 of rdg 10 digits 600V 1V 1 2 of rdg 10 digits Overload Protection 600V dc or rms ac for all ranges Frequency range 40Hz to 400Hz Response Average responding calibrated in rms of a sine wave DIODE amp CONTINUITY Range Accuracy on If continuity exists about less than 1000 built in buzzer will sound r Show the approx forward voltage drop of the diode Overload Protection 250V dc or rms ac RESISTANCE Resolution Accuracy 2000 0 10 0 8 of rdg 3 digits 2kQ 10 0 8 of 2 digits 20k0 100 0 8 of rdg 2 digits 200kQ 1000 0 8 of rdg 2 digits 2MQ 1kQ 1 0 of rdg 2 digits Maximum Open Circuit Voltage 3 2 V Overload Protection 250V dc or rms ac fo
3. 600V sobre el nivel del suelo en instalaciones de categor a II Cuando la escala de valores a medir se conoce de antemano sit e el selector de escalas en la posici n m s alta Antes de girar el selector de escalas para cambiar de funci n desco necte los cables de prueba del circuito a prueba Al realizar mediciones de televisores o al cambiar los circuitos el c tricos siempre recuerde que puede haber pulsos de voltajes de gran amplitud en los puntos de prueba que pueden danar al mult metro Siempre sea cuidadoso al trabajar con voltajes superiores a los 60V cd 30V ac rms Mantenga sus dedos detr s de las barreras de detecci n cuando realice mediciones de voltaje con cables de prueba Nunca realice mediciones de resistencia sobre circuitos vivos DESCRIPCI N GENERAL El medidor es un mult metro digital port til 31 2 para realizar medicio nes de voltaje CD y CA Corriente CD Resistencia Diodo y Prueba de Continuidad con funcionamiento a bater a El mult metro cuenta con la funci n de luz de fondo que se utiliza en ambientes oscuros 14 PANEL FRONTAL 15 KNOVA DESCRIPCION DEL PANEL FRONTAL 1 Indicador de detecci n de voltaje sin contacto LED rojo 2 Pantalla de 3 1 2 d gitos cuenta hasta 2000 LCD 3 Luz de fondo Cuando se pulsa este bot n se enciende la Luz de fondo de la pantalla Luego de aproximadamente 10 segundos la Luz de fondo se apaga autom ticamente 4
4. 2 digitos 200kQ 100Q 0 8 de lectura 2 digitos 2MQ 1kQ 1 0 de lectura 2 digitos M ximo Voltaje de Circuito Abierto 3 2V Protecci n de Sobrecarga 250V cd ca rms para todas las escalas Detecci n de voltaje sin contacto Resoluci n gt AC9OV Se enciende el LED rojo 19 KNOVA INSTRUCCIONES DE OPERACION MEDICION DE VOLTAJE CD 1 2 Conecte el cable de prueba rojo al VO mA el cable de prueba negro al conector COM Sit e el interruptor rotativo en la posici n DCV deseada Si el voltaje a medir no se conoce de antemano sit e el selector de escalas en la posici n de escala m s alta y luego red zcala hasta alcanzar una resoluci n satisfactoria Conecte los cables de prueba a la fuente o carga a medir Lea el valor del voltaje que se visualiza en la pantalla LCD junto con polaridad de la conexi n del cable rojo MEDICI N DE CORRIENTE CD Conecte el cable de prueba rojo al conector y el cable de prueba negro al conector COM Para mediciones de entre 250mA y 10A retire el cable rojo del conector 10A Sit e el interruptor rotativo en la posici n DCA deseada Abra el circuito en el que se encuentra la corriente a medir y conecte los cables de prueba en serie al circuito Lea el valor de la corriente que se visualiza en la pantalla LCD junto con la polaridad de la conexi n del cable rojo MEDICI N DE
5. BATTERY amp FUSE REPLACEMENT If E appears on display it indicates that the battery should be replaced The fuse rarely needs replacement and blows almost always as a result of operator s error To replace the battery and the fuse 250mA 250V and 10A 250V remove the 2 screws in the bottom of the case Simply remove the old one and replace with a new one Be careful to observe battery polarity A WARNING Before attempting to open the case always be sure that test leads have been disconnected from measurement circuits Close case and tighten screws completely before using the meter to avoid electrical shock hazards ACCESSORIES Operator s instruction manual Set of test leads Gift box 9 volt battery NEDA 1604 6F22 006P type optional 11 KNOVA TABLA DE CONTENIDOS Informacion de seguridad 3 Simbolos de seguridad 3 Mantenimiento 3 Durante el uso 4 Descripci n general 4 Panel frontal 15 16 Especificaciones 6 General 16 19 Instrucciones de operaci n 20 22 Cambio de bateria y fusibles 23 Accesorios 23 INFORMACION DE SEGURIDAD Este mult metro ha sido dise ado de acuerdo a la IEC61010 1 concerniente a los instrumentos electr nicos de medici n con una categor a de sobretensi n CATII y contaminaci n de grado 2 Siga todas las instrucciones de operaci n y seguridad para garantizar el uso seguro del mult metro y su mantenimiento en buenas cond
6. Back light When this button is pushed the Back light of display is turned on After about 10 seconds the Back light will be turned off automatically In order to turn on the Back light again just push this button once 4 Hold button When this button is pushed the display will keep the last reading and symbol will appear on the LCD until you push it again 5 Rotary switch This switch is used to select functions and desired ranges as well as to turn on off the meter 6 COM jack Plug in connector for black negative test lead 7 10A jack Plug in connector for red test lead for10A measurement 8 VOmA jack Plug in connector for red positive test lead for voltage resistance and current except 10A measurements SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 8096 GENERAL Maximum voltage between terminals and earth ground CATII 600V Fuse protection F 250mA 250V 10A 250V Power 9V battery NEDA 1604 or 6F22 Display LCD 2000 counts updates 2 3 sec Measuring method Dual slope integration A D converter Over range Indication Only figure 1 on the display Polarity indication displayed for negative polarity Operating Environment 0 to 40 C Storage temperature 10 C to 50 C Low battery indication E appears on the display Size 140mm x67mm x 30mm Weight Approx 1 12g DC VOLTAGE
7. VOLTAJE CA 1 2 3 4 Conecte el cable de prueba rojo al conector V O mA y el cable de prueba negro al conector COM Sit e el interruptor rotativo en la posici n ACV deseada Conecte los cables de prueba a la fuente o carga a medir Lea el valor del voltaje que se visualiza en la pantalla LCD 20 MEDICION DE RESISTENCIA 1 Conecte el cable de prueba rojo al conector V O mA el cable de prueba negro al conector COM La polaridad del cable rojo es positiva 2 Sit e el interruptor rotativo en la posici n de escala O Conecte los cables de prueba al reactor a medir y lea la pantalla LCD 4 Si la resistencia medida se conecta a un circuito apague la corriente y descargue todos los condensadores antes de aplicar los sensores de prueba Co PRUEBA DE DIODOS 1 Conecte el cable de prueba rojo al conector V O mA el cable de prueba negro al conector COM La polaridad del cable de prueba rojo es positiva 2 Sit e el interruptor rotativo en la posici n de escala Lr 3 Conecte el cable de prueba rojo al nodo del diodo a medir y el cable de prueba negro al c todo del diodo Se visualizar la ca da aproximada del voltaje directo del diodo Si la conexi n est invertida nicamente se mostrar la figura 1 PRUEBA DE CONTINUIDAD AUDIBLE 1 Conecte el cable de prueba rojo al conector V O mA el cable de prueba negro al conector COM 2 Sit e el interrup
8. Bot n Retener Cuando se pulsa este bot n la pantalla retendr la ltima lectura y se visualizar el s mbolo F J en el LCD hasta que el mismo se vuelva a pulsar 5 Interruptor rotativo Este interruptor se utiliza para seleccionar las fun ciones y escalas deseadas as como para encender apagar el mult metro 6 Conector COM Conector de entrada para el cable de prueba negro negativo 7 Conector de 10A Conector de entrada para el cable de prueba rojo para mediciones de 10A 8 Conector VOmA Conector de entrada para el cable de prueba rojo positivo para mediciones de voltaje resistencia y corriente exceptuando 104 ESPECIFICACIONES La precisi n se especifica por el per odo de un luego de la calibraci n yauna temperatura de 18 C a 28 C 64 F a 82 F con una humedad relativa de hasta el 8096 GENERAL M ximo voltaje entre terminales y tierra CATII 600V Protecci n con Fusible F 250mA 250V 10A 250V Energ a 9V battery NEDA 1604 or 6F22 Pantalla LCD 2000 counts updates 2 3 sec M todo de Medici n Dual slope integration A D converter Indicaci n de Sobrepaso de escala Only figure 1 on the display Indicaci n de polaridad displayed for negative polarity Temperatura Ambiente de Operaci n 0 to 40 C Temperatura de almacenamiento 10 C to 50 C Aviso de bateria baja appears on the display Tamano 140mm x67mm 30mm Peso 1129 16 VOLTAJE CD Escala R
9. d lead is positive 2 Set the rotary switch at desired O range position 3 Connect test leads across the resistor to be measured and read LCD display 4 If the resistance being measured is connected to a circuit turn off power and discharge all capacitors before applying test probes DIODE TEST 1 Connect the red test lead to V O mA jack and the black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at PF position 3 Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode The approx forward voltage drop of the diode will be displayed If the connection is reversed only figure 1 will be shown AUDIBLE CONTINUITY TEST 1 Connect red test lead to V O mA black test lead to COM 2 Set range switch to en position 3 Connect test leads to two points of circuit to be tested If continuity exists built in buzzer will sound 9 KNOVA Non contact voltage detection 1 When the meter head is close to the AC voltage field the LED light the close distance is about 30mm from the AC voltage field A WARNING Even without LED indication the voltage may still exist Do not rely on non contact voltage detector to determine the presence of voltage wire Detection operation may be subject to socket design insulation thickness and different type and other factors 10
10. esoluci n Precisi n 200mV 100uV 0 5 de lectura 2 digitos 2V 1mV 0 5 de lectura 2 digitos 20V 10mV 0 5 de lectura 2 digitos 200V 100mV 0 5 de lectura 2 digitos 600V 1V 0 8 de lectura 2 digitos Protecci n de Sobrecarga 250V rms Para una escala de 200mV y 600V cd ca rms para otras escalas CORRIENTE CD Escala Resoluci n Precision 200u4A O 1uA 1 de lectura 2 digitos 2mA 14A 1 de lectura 2 digitos 20mA 104A 1 de lectura 2 digitos 200 1004A 1 5 de lectura 2 digitos 10A 10mA 3 de lectura 2 digitos Protecci n de Sobrecarga Fusible 250mA 250V Fusible 10A 250V 17 KNOVA VOLTAJE Escala Resoluci n Precision 200V 100mV 1 2 de lectura 10 digitos 600V 1V 1 2 de lectura 10 digitos Protecci n de Sobrecarga 600V cd ac rms para todas las escalas Escala de frecuencia 40Hz a 400Hz Respuesta Respuesta promedio calibrada en rms de onda sinusoidal DIODOS amp CONTINUIDAD Escala Descripci n on Si hay continuidad por ejemplo una resistencia menor a 1000 sonar la alarma incorporada gt Muestra la ca da del voltaje directo aproximado del diodo Protecci n de Sobrecarga 250V cd rms ac RESISTENCIA Escala Resoluci n Precisi n 2000 0 10 0 8 de lectura 3 digitos 2kQ 10 0 8 de lectura 2 digitos 20k0 100 0 8 de lectura
11. etely Do not use abrasives or solvents on the meter To clean It use a damp cloth and mild detergent only 1 KNOVA DURING USE Never exceed the protection limit values indicated in the specifications for each range of measurement When the meter is linked to measurement circuit do not touch the unused terminals Never use the meter to measure voltages that might exceed 600V above earth ground in category II installations When the value scale to be measured is unknown beforehand set the range selector at the highest position Before rotating the range selector to change functions disconnect test leads from the circuit under test When carrying out measurements on TV or switching power circuits always remember that there may be high amplitude voltages pulses at test points which can damage the meter Always be careful when working with voltages above 60Vdc or 30V ac rms Keep fingers behind the probe barriers when making voltage measurements with test leads Never perform resistance measurements on live circuits GENERAL DESCRIPTION The meter is a handheld 31 2 digital multimeter for measuring DC and AC voltage DC current Resistance Diode and Continuity Test battery operated The meter has a back light function to be used in a dark environment FRONT PANEL 3 KNOVA FRONT PANEL DESCRIPTION 1 Non contact voltage detection indicator red LED 2 Display 3 1 2 digit 2000 count LCD 3
12. iciones operativas El cumplimiento total de los est ndares de seguridad s lo puede garantizarse si se utilizan los cables de prueba provistos De ser necesario deben reemplazarse por unos del mismo tipo especificado en este manual S MBOLOS DE SEGURIDAD A Informaci n de seguridad importante rem tase al manual de operaci n 4 Posible presencia de voltaje peligroso X Anti basura n Doble aislamiento Protecci n de clase II El fusible debe ser cambiado por uno de la categor a especificada en el manual MANTENIMIENTO Antes de abrir la carcasa desconecte siempre los cables de prueba de todos los circuitos con electricidad Para una protecci n contra el fuego asegurada reemplace el fusible nicamente por uno con el voltaje y las categor as de corriente especificados 250mA 250V Acci n R pida 10A 250V Acci n R pida Nunca utilice el mult metro a menos que la cubiertatrasera est ubicada y ajustada completamente No utilice abrasivos ni solventes sobre el mult metro Para limpiarlo utilice un pa o h medo y detergente suave nicamente 13 KNOVA DURANTE EL USO Nunca sobrepase los valores del limite de protecci n indicados en las especificaciones para cada escala de medici n Cuando el mult metro est conectado a un circuito de medici n no toque las terminales que no est n en uso Nunca utilice el mult metro para medir voltajes que puedan exceder los
13. r all ranges Non contact voltage detection Resolution gt AC90V Red LED lit KNOVA OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT 1 Connect the red test lead to the V O mA jack and the black lead to the COM jack 2 Set rotary switch at desired DCV position If the voltage to be measured is not known beforehand set range switch at the highest range position and then reduce it until satisfactory resolution is obtained 3 Connect test leads across the source or load being measured 4 Read voltage value on the LCD display along with the polarity of the red lead connection DC CURRENT MEASUREMENT 1 Connect the red test lead to the V O mA jack and the black test lead to COM jack For measurements between 250mA and 10 remove red lead to 10A jack 2 Set the rotary switch at desired DCA position 3 Open the circuit in which the current is to be measured and connect test leads in series with the circuit 4 Read current value on LCD display along with the polarity of red lead connection AC VOLTAGE MEASUREMENT 1 Connect the red test lead to V O mA jack and the black test lead to the COM jack 2 Set the rotary switch at desired ACV position 3 Connect test leads across the source or load being measured 4 Read voltage value on the LCD display 8 RESISTANCE MEASUREMENT 1 Connect the red test lead to V Q mA jack and black test lead to the COM jack The polarity of re
14. tor de escalas en la posici n er 3 Conecte los cables de prueba a dos puntos del circuito a probar Si hay continuidad sonar la alarma incorporada 21 KNOVA Detecci n de voltaje sin contacto 1 Cuando el mult metro se acerca al campo de voltaje CA el LED indicar que la distancia m s cercana es de aproximadamente 30mm del campo de voltaje CA A ADVERTENCIA Incluso sin la indicaci n del LED es posible que haya voltaje No conf e en el detector de voltaje sin contacto para determinar la presencia de un cable de voltaje ya que la operaci n de detecci n car a de acuerdo al dise o del enchufe espesor y tipo del aislamiento entre otros factores 22 CAMBIO DE amp FUSIBLES Si se visualiza el simbolo en la pantalla estar indicando que bater a debe ser reemplazada Los fusibles rara vez necesitan ser reemplazados y casi siempre se que man como consecuencia de un error del operador Para reemplazar la bater a y el fusible 250mA 250V and 10A 250V retire los dos tornillos de la parte inferior de la carcasa Simplemente retire el elemento viejo y reempl celo por uno nuevo Aseg rese de contemplar la polaridad de la bater a A ADVERTENCIA Antes de intentar abrir la carcasa aseg rese de que los cables de prueba est n desconectados de los circuitos de medici n Cierre la carcasa y ajuste los tornillos completamente antes utilizar el mult metro a fin de e
15. vitar riesgos de descarga el ctrica ACCESORIOS e Manual del operador e Juego de cables de prueba e Caja de regalo e Bater a de 9 voltios tipo NEDA 1604 6F22 006P opcional 23 KNOVA 9 www knova com mx Herramientas para siempre