Home
G120MG2200TH GENERADORES
Contents
1. EVANS GENERADORES F E MA AA AA WW WD m ae s F 227 sam zt Powered by G120MG2200TH TE MANUAL DE PROPIETARIO ANTES DE USAR SU EQUIPO LEA SU MANUAL DE PROPIETARIO COD 70080399 ver 0514 SPECIFICATIONS SPECIFICATIONS Type Frequency Peak Power Capacity Voltage Max Rated current Voltage regulation Type Model Brand Displacement Max power Fuel Fueltank capacity Fuel consumption 75 Load Fuel consumption 100 Load Oil capacity Starting system Oil presure sensor Duplex single phase receptacle Twist lock two phase receptacle Main breaker Overload protection Voltmeter Hourmeter ALTERNATOR PANEL Noise level Struture Accesories Net weight Overal dimensions WxLxH w o GENERATOR G120MG2200TH SINGLE PHASE 2 POLES BRUSHLESS 60 Hz 12 000 WATTS 11 000 WATTS 240 120 V 50 100 DIODES WITH VARISTORS AIR COOLED 4 STOKES V TWIN CYLINDER OHV GASOLINE ENGINE MGT 670GAE THUNDER 670 cc 22 HP 3600 RPM UNLEADED GASOLINE 7 9 GALLONS 1 29 GAL HR 1 76 GAL HR 0 41 GALLONS ELECTRIC PRESSURE BULB 5 20R 2 PIECES L14 30R 2 PIECES MCCB 504A 2 pole 1 PIECE 0 300 VOLTS 1 PIECE DIGITAL 1 PIECE 85 Db 23 FT 1 25 SQUARE TUBE WHEELS AND HANDLE KIT 298 LB 22 7 16 X 33 1 16 X 31 3 32 IN SAFETY IN
2. O Siempre siga los c digos y regulaciones locales que se aplican a la instalaci n de cualquier equipo que tenga relaci n con este producto NFPA 70 C digo Nacional El ctrico NFPA 30 Est ndar para la instalaci n y uso de motores estacionarios de combustible Manual de cableado agr cola de la energ a el ctrica en posici n auxiliar para granjas ANTES DE LA INSTALACI N PUESTAA TIERRA DEL GENERADOR EL C digo Nacional El ctrico requiere que este producto se conecte adecuadamente a una puesta de tierra para prevenir un choque el ctrico Para este prop sito se proporciona una terminal de tierra conectada al marco del generador Conecte una punta de un cable de cobre desnudo calibre 12 AWG m nimo a la terminal de tierra situada en el marco del equipo se identifica por una calcoman a con el s mbolo de tierra f sica ver figura abajo y laotra punta del cable a una varilla de cobre enterrada en el suelo 1metro la cual deber proporcionar una conexi n a tierra adecuada Sin embargo consulte con un electricista local para asegurarse que los c digos locales se cumplen adecuadamente M F Terminal de puesta a tierra Conectar un cable de cobre desnudo 12 AWG entre la terminal de tierra y un punto de aterrizado adecuado A ADVERTENCIA No use una tuber a que conduzca materiales combustibles como punto de conexi n a tierra 18 evans com mx LUBRICACION NO intente arrancar este
3. la formaci n de dep sitos de goma de gasolina durante el almacenamiento El aditivo de gasolina puede agregarse a la gasolina en el tanque de combustible o junto con la gasolina en un contenedor de almacenamiento El combustible y el humo del motor son inflamables y potencialmente explosivos Utilice un procedimiento adecuado para almacenar y manejar combustible Siempre tenga extinguidores ABC a la mano PRECAUCION No llene demasiado el tanque Mantenga un nivel m ximo de combustible a 1 4 de pulgada por debajo de la parte superior del tanque de combustible Esto permitir la expansi n durante el clima c lido evitando as el derrame EXTENSIONES ELECTRICAS Q Todas las cargas del generador seran conectadas al panel mediante extensiones o cables y deberan ser hechas con clavijas o enchufes aterrizados de 3 espigas para los receptaculos de 127 volts y con clavijas o enchufes de 5 espigas para los receptaculos de 127 220 volts ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO Tabla 3 Aislamiento doble 6 SR Canadian Standards Association Underwriters Laboratories Inc Voltaje de corriente alterna m 00 Ng EN xxxx min RPM sin carga 39 16 1 20 0 Basado en una l nea con un voltaje con una caida de 5 volts al 15096 de su carga nominal H A L14 30P 5 20P Oneti rase a la tabla para los calibres m nimos de extensi n el ctrica de acuerdo con las necesidades de las
4. 15200553 WHEEL AXE 2 ENGINE MUFFLER ENGINE MANIFOLD MUFFLER SUPPORT BATERY BASE BATERY HOLDER NOTE Some parts are listed and shown for illustration purposes only and not available individually as replacement parts 12 evans com mx SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Ah WARNING The engine exhaust from this product contains one or more chemicals chemicals known to the known to the State of State of California to cause California to cause cancer cancer birth defects or and birth defects or other other reproductive harm reproductive harm This product contains RECOGNIZE SAFETY INFORMATION This is the safety alert symbol When you see this symbol on your product or in this manual be alert to the potential for personal injury Follow recommended precautions and safe operating practices UNDERSTAND SIGNAL WORDS A signal word DANGER WARNING or CAUTION is used with the safety alert symbol ADANGER DANGER identifies the most A WARNING serious hazards A CAUTION DANGER or WARNING safety signs are located near specific hazards General precautions are listed on CAUTION safety signs CAUTION also calls attention to safety messages in this manual WORK IN A VENTILATED AREA Engine exhaust fumes can cause sickness or death If itis necessary to run an engine in an enclosed area remove the exhaust fumes from the area with an exhaust pipe extension If you do not
5. BS JE MAE cpm 10 evans com mx SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE M100LL ALTERNATOR ASSEMBLY DRAWING M100LL ALTERNATOR DESCRIPTION QTY IP23 Outlet grid 2 1 1 1 Complete wound rotor Drive end bracket 1 2 3 Fan Wound Frame Complete compound set 1 Slip ring 5 7 1 11 1 12 1 15 1 16 1 19 Blind or wired cover 1 Block de terminales de 6 tornillos 1 Assembling screw kit Terminal board connection screw kit 1 47 48 74 150 Plastic plug 1 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERE TO evans com mx 11 GENERATOR GENERAL ASSEMBLY DRAWING MATERIALS LIST DESCRIPTION QTY C 5 7 79
6. MOTOR A GASOLINA MGT 670GAE THUNDER 670 cc 22 HP 3600 RPM GASOLINA SIN PLOMO 30 LITROS 4 88 L HR 6 5 L HR 1 55 LITROS ELECTR CO BULBO DE PRESI N 5 20R 2 PIEZAS L14 30R 2 PIEZAS MCCB 50AMPS 2 POLOS 1 PIEZA 0 300 VOLTS 1 PIEZA DIGITAL 1 PIEZA 95 dB 7m BASE DE TUBO CUADRADO 1 25 KIT DE RUIDAS Y MANIJAS 135 kg 57 x 84 x 79 cm Para evitar un arranque inesperado siempre retire el cable de la buj a antes de dar mantenimiento al generador o al motor REGLAS DE SEGURIDAD Y FUNCIONAMIENTO ADVERTENCIA El no seguir estas instrucciones y advertencias puede ocasionar muerte heridas personales o da os materiales Lea cuidadosamente y entienda el manual del operador antes de utilizar este producto Lea y entienda el manual de motor antes de su funcionamiento Siga todas las advertencias e instrucciones Conozca su equipo Considere las aplicaciones limitaciones y los riesgos potenciales espec ficos de su unidad El equipo deber colocarse sobre una base de sustentaci n firme La carga debe de mantenerse dentro de los valores nominales que aparecen en la placa de identificaci n del generador Una sobrecarga da ar la unidad o acortara su vida til No se debe de hacer funcionar el motor a velocidades demasiado altas Si se opera el motor a excesiva velocidad aumenta el riesgo de lesiones f sicas No toque a cambie piezas que puedan aumentar o disminuir la velocidad regu
7. grounded plug for connection to 127 220 volts outlet oee Table 3 for select the minimum cable gauge of extensions or cords in agreement with the necessities of the loads When the load increases must be used a cable extension of greater size Using extensions of inadequate size it is in where can result in serious problems with the voltage reducing the electric energy applied to the tools and causing damage on them As far as smaller is the number of the wire gauge greater is the conduction capacity an example is that A wire gauge 14 for example can lead a current higher than a wire gauge16 When several extensions are connected it is a must to review that each extension is of the minimum gauge required If you need to use an extension with outlets to connect more than one electric tool sum the amperes marked in the nameplates of each tool to determine the minimum cord gauge you need to use The extensions for 127 volts are made of 3 cables where the green cable is the grounding one the white cable is the neutral and the black cable is the hot wire dl 5 20P g L14 30P The extensions for exits of 127 220 are made of 5 cables where the green cable is the grounding one the white cable is the neutral and the yellow cables are the hot wires UNPACKING When umpacking check to make sure that all parts are included Refer to the General Assembly Drawing and Parts List at the end of this ma
8. BEEN SITTING FOR A WHILE If your unit has not been used for a long period of time and it is hard to start it try to do some of these easy steps before calling the customers hotline Check the oil level Replace the old fuel Echange the spark plug Q Check the fuel lines Make sure the fuel valve is open O check all generator parts for integrity Clean the carburetor See engine manual for service centers SERVICE AND STORAGE INFREQUENT SERVICE If the unitis used infrequently difficult starting may result to eliminate hard starting run the generator at least 30 minutes every 15 days Also if the unit will not be used for some time it is a good idea to drain the fuel from the carburetor and gas tank LONG TERM STORAGE When the generator set is not being operated or is being stored more than one month follow these instructions Replenish engine oil to upper level Drain gasoline from fuel tank line and carburetor Pour about one teaspoon of engine oil through the spark plug hole pull the recoil starter several times and replace the plug Then pull the starter until you feel piston is on its compression stroke and leave it in that position This closes both the intake and exhaust valves to prevent the inside of cylinder from rusting O cover the unit and store in a clean dry place that is well ventilated away from open flame or sparks NOTE We recommend always using a fuel stabilizer A fuel stabil
9. attached to the generator s frame identified with a label with the ground symbol see figure below and a cooper rod drawn 1 meter into the ground which should provide a suitable ground connection However consult with a local electrician to insure that local codes are being adhered to LUBRICATION WARNING A WARNING do not use a pipe carrying combustible material as the ground source VARIATION OF RATED WATTS BY ALTITUDE AND TEMPERATURE ALTITUDE 0 500 1000 3280 096 1800 2000 3000 9840 0 75 evans com mx TEMPERATURE 0 91 Meters Feet 0 C 32 F 21 C 70 F 50 122 F 75 167 F 100 C 212 F 0 85 1 on oe o os SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Generator Ground Terminal Connect a bare 12 AWG copper cable from the ground terminal to an earth grounding point O DO NOT attempt to start the engine without filling the engine crankcase with the proper amount and type of oil Use SAE 30 oil Your generator has been shipped from the factory without oil in the engine crankcase Operating the unit without oil can damage the engine and lose the warranty Fill the engine according to the engine manual In this engine the plastic plug of the engine crankcase is the oil fill and check plug Fill with oil and check the level using the marks settings in the dipstick LOW OIL SENSOR The engine is equipped with an oil sensor If the oil
10. ctricos con chispas como herramientas mec nicas soldadoras y rectificadoras El motor deber tener instalado siempre el silenciador y el filtro de aire los cuales deber n de estar en buenas condiciones en todo momento ya que detienen el fuego en caso de una ignici n incompleta en el motor No fume cerca del generador Cerci rese que el generador est conectado a tierra correctamente consulte la secci n Puesta a Tierra del Generador No use ropa demasiado holgada alhajas o cualquier otra 16 cosa que se pueda atrapar el alternador u Jos partes movibles QN La unidad debe de alcanzar la velocidad de operaci n antes de conectarse las cargas el ctricas Desconecte las cargas antes de apagar el motor 16 evans com mx Para evitar sobrecargas que podr an da ar el equipo permita que el motor se quede sin combustible al aplicarse las cargas el ctricas Al dar carga a un equipo de estado s lido debe utilizarse pun protector de sobrecarga para evitar posibles da os al equipo No coloque nada a trav s de las ranuras de ventilaci n g aun cuando el generador no est en operaci n Esto puede da ar al generador o causar lesiones personales Antes de transportar el generador en veh culo extraiga todo el combustible para evitar la posibilidad de fugas o derrames Use t cnicas correctas para alzar el generador de un lugar a otro De lo contrario podr an producirse lesiones eo pe
11. generator review that all the pieces are complete review if there are damaged cables or some other condition that can affect that the generator operates on safe way If a strange noise is listened to or some abnormal vibration turn off the generator immediately Be sure to fix the problem before giving the generator more use Do not use the equipment damaged O Periodically inspect all the screws and bolts to check they are in place and tight Keep this equipment in a clean and dry place For the best maintenance of the engine and any other problem read the engine owner s manual After the engine has become cool remove the excessive gasoline and store it in a container safe and approved for that purpose O Atter the first 20 hours of use of the generator drain and replace the oil of the engine after that the oil must be changed every 100 working hours HEAT SHIELD Inspect to ensure that all heat shields and heat deflectors are intact and in place Removing of these parts could cause serious damage to the unit ENGINE Carburetor Icing During the winter months rare atmospheric conditions could cause an icing condition in the carburetor If it happens the engine may run rough loose power and may stall Call Product Service for more information NOTE Refer to the engine manufacturer s manual for service and maintenance of the engine SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE QUICK STARTING TIPS FOR UNITS THAT HAVE
12. have an exhaust pipe extension do not use the generator in an enclosed area FOLLOW SAFETY INSTRUCTIONS Carefully read all safety messages in this manual and on your product safety signs Keep safety signs in good condition Replace missing or damaged safety signs Be sure new product components and repair parts include the current safety signs Learn how to operate the product and how to use controls properly Do not let anyone operate without instruction Keep your product in proper working condition Unauthorized modifications to the product may impair the function and or safety and affect product life If you do no understand any part of this manual and need assistance contact your Distributor SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE HANDLE FUEL SAFETY AVOID FIRES Handle fuel with care it is highly flammable Do not refuel the product while smoking or when near open flame or sparks Always stop engine before refueling product Fill fuel tank outdoors Prevent fires by keeping product clean of accumulated trash grease and s Always clean up spilled uel DRAIN GASOLINE WHEN STORING YOUR PRODUCT Gasoline stored in fuel tank can explode Never store your product with gasoline in the tank inside a building where fumes may reach an open flame or spark Always drain gasoline from fuel tank and carburetor bowl when storing your product Allow engine to cool before storing PREPARE FOR EM
13. level becomes lower than required the sensor will activate a warning device and stop the engine see the accompanying engine manual for more information If the generator turns off and the oil level is within specifications check that the generator is not placed at an angle that forces the oil level to change Place the generator in an even area to correct this problem If the engine doesn t start the oil level could not be enough to shut off the automatic low oil swith Make sure the oil cap is in the correct level FUEL Fill the tank with unleaded fuel clean and new You can use regular grade fuel as long as it has a high octane value at least 85 octane Always use a fuel additive A fuel additive will minimize the development of fuel gum deposits during storage The fuel additive can be added to the fuel int the gas tank or put toguether to the fuel in a storage container The fuel and engine smoke are flammable and potentially explosive Use a suitable procedure to store and handle fuel Always have ABC fire extinguisher nearby 4h CAUTION Do not overfill the tank Keep maximum fuel level to 1 4 inch below the top of the tank This will allow for expansion during warm weather and so avoiding spillage Table 3 ELECTRIC EXTENSIONS OR CORDS All generator loads will be connected from the control panel with extensions or cords with 3 prong grounded plug for connection to 127 volts outlet and 5 prong
14. motor sin llenar el c rter con la cantidad y el tipo de aceite adecuado Utilice aceite SAE 30 Su generador ha sido enviado de f brica sin aceite en el c rter El operar la unidad sin aceite puede arruinar el motor Llene el motor con aceite de acuerdo con el manual del motor En este motor el tap n de pl stico del c rter por donde se le llena de aceite contiene la bayoneta con las marcas de lleno y vac o e EL SENSOR DE BAJO NIVEL DE ACEITE Esta unidad esta equipada con un sensor de nivel bajo de aceite Inicialmente si el nivel de aceite es menor que el requerido el sensor activar un artefacto y parar el motor Consulte el manual adjunto del motor para m s informaci n Si se apaga el generador y el nivel de aceite se encuentra dentro de las especificaciones verifique que el generador no est colocado a un ngulo que obligue a que el aceite var e su nivel Col quelo sobre una superficie pareja para corregir este problema Si el motor no arranca el nivel de aceite podr a no ser el suficiente como para desactivar el interruptor de bajo nivel de aceite Aseg rese de que el tap n de aceite marque que est en nivel correcto COMBUSTIBLE Llene el tanque con gasolina sin plomo para autom viles limpia y nueva Puede usarse gasolina de grado regular siempre y cuando se obtenga un valor alto de octanaje por lo menos 85 octanos Recomendamos que siempre utilice un aditivo de gasolina Un aditivo de gasolina minimizar
15. vea este s mbolo en el producto o en este manual este alerta ante la posibilidad de lesiones personales Siga las precauciones recomendadas y las pr cticas de operaci n seguras ENTIENDA PALABRAS DE ALERTA Una palabra de alerta PELIGRO ADVERTENCIA PRECAUCION se utilizan con el s mbolo de alerta de seguridad W Wiz 3N e 16 PELIGRO Identifica los riesgos m s graves ADVERTENCIA PELIGRO O ADVERTENCIA Sefiales de seguridad se PRECAUCION encuentran cerca de los peligros espec ficos Precauciones generales se utilizan en las sefiales de precauci n de seguridad PRECAUCION se ales de precauci n de seguridad PRECAUCION tambi n llama la atenci n a los mensajes de seguridad en este manual REVISE SU GENERADOR Aseg rese de que todas las cubiertas y protectores est n en su lugar Localice todos los controles de funcionamiento y las etiquetas de seguridad TRABAJE EN UN AREA VENTILADA Los gases del escape del motor pueden causar enfermedad o muerte Si es necesario encender un motor en rea cerrada utilice una extensi n de tuber a del escape hacia el exterior Si usted no tiene una extensi n NO es recomendable encender el motor MANEJE EL COMBUSTIBLE CON SEGURIDAD EVITE INCENDIOS Maneje el combustible con e cuidado es altamente inflamable Q No llenar el tanque de combustible mientras est fumando o cerca de D llamas abiertas o chispas Siempre apague el motor antes de llenar el tan
16. 50 Paloquemao Tel PBX 00 571 360 7051 Fax 00 571 237 0661 Bogot D C Colombia www valsicolombia com ventas valsicolombia com
17. AL Coloque el extremo del generador sin llantas sobre los bloques de madera permitiendo un espacio para colocar el soporte del generador Fije el soporte frontal a la base con los tornillos suministrados y aprietelos bien como se indica en el dibujo 17 j l ii y C A 2 SS 4 Vv Y C k x lt L NQ Y MIA 5 E A PRECAUCION A Antes de instalar la bater a quite la llave del Panel de control de su generador Monte sobre la base del generador el portabaterias y asegurelo con el tornillo rondana y tuerca como se indica en el dibujo 9 C loque la bater a sobre el soporte Asegure la bater a usando los soportes que se sujetan sobre la base Identifique los cables rojo y negro con los electrodos negativo y positivo de la bater a G Conecte el cable rojo a la terminal positivo de la bateria y el cable negro al terminal negativo Vea la figura Maneje con cuidado la bater a ya que contiene acidos muy corrosivos y puede causar quemaduras Nunca conecte el cable rojo al negro esto puede causar da os a su integridad f sica y a su equipo evans com mx 20 CONTROLES DEL MOTOR Ahogador Bayoneta de aceite PANEL DE CONTROL owitch d Hor met Indicador de Interruptor termomagnetico A eral ey er Energ a para la Vida I WWW 203 mr TM FI Monitor de Voltaje Sal
18. EJOS PARA UN ENCENDIDO RAPIDO EN UNIDADES QUE HAN ESTADO INHABILITADAS DURANTE UN TIEMPO Si su unidad ha estado fuera de servicio durante un periodo de tiempo extenso y es dif cil que encienda intente realizar algunos de estos f ciles pasos antes de llamar a la l nea directa de informaci n de servicio al cliente Verifique el nivel de aceite Reemplace el combustible viejo Cambie la buj a de encendido Verifique los ductos de combustible Aseg rese que la v lvula de combustible est abierta Verifique la integridad de todas las piezas del generador Limpie el carburador consulte el manual de motor para obtener informaci n sobre los centros de servicio SERVICIO Y ALMACENAMIENTO SERVICIO POCO FRECUENTE Si la unidad no se utiliza frecuentemente podr an surgir dificultades para arrancar Para eliminar estos problemas haga funcionar el generador por lo menos 30 minutos cada 15 d as Adem s si la unidad no se va a utilizar durante alg n tiempo es conveniente extraer el combustible del carburador y del tanque de gasolina ALMACENAMIENTO A LARGO PLAZO Cuando el equipo generador no se est operando o est almacenado durante m s de un mes siga las instrucciones siguientes Vuelva a llenar de aceite el motor hasta su nivel superior Saque la gasolina del tanque de combustible la l nea Qae combustible y del carburador Vierta hasta una cucharadita de aceite para motores a del orificio de la buj a t
19. ERGENCIAS Est preparado en caso de incendio Mantenga un extinguedor y un botiquin de primeros auxilios Mantenga los n meros de emergencia a mano SERVICIO PREVENTIVO DE SU GENERADOR Antes de darle mantenimiento a su generador desconecte todos los aparatos y permita que la unidad se enfrie Haga su servicio preventivo en un rea plana limpia y seca bloquee las ruedas para evitar que la unidad se mueva evans com mx AN 27 Distribuido por Consorcio Valsi S A de C V Camino a C ndor No 401 El Castillo Carretera Guadalajara El Castillo km 11 4 C P 45680 Tel 52 33 3208 7400 RFC CVA991008945 El Salto Jalisco M xico Sucursales Nacionales MEXICO D F Tel 52 55 5566 4314 5705 6779 Fax 52 55 5705 1846 GUADALAJARA Av Gobernador Curiel No 1777 Col Ferrocarril C P 44440 Tel 52 33 3668 2500 Fax 52 33 3668 2551 ventas evans com mx Exportaciones 52 33 3668 2560 Fax Exportaciones 52 33 3668 2557 export evans com mx www valsi net SERVICIO Y REFACCIONES Tel 52 33 3668 2500 3668 2572 Fax 52 33 3668 2576 MONTERREY N L Tel 52 81 8351 6912 8351 8478 8331 9078 Fax 52 81 8331 5687 CULIACAN SIN Tel 52 667 1469329 30 31 32 Fax 52 667 146 9329 Ext 19 PUEBLA PUE Tel 52 222 240 1798 240 1962 Fax 52 222 237 8975 MERIDA YUC Tel 52 999 212 0955 Fax 52 999 212 0956 Sucursales en el Extranjero VALSI DE COLOMBIA LTDA Carrera 27 No 18
20. ERGENCIES Be prepared if a fire starts Keep a first aid kit and fire extinguisher handy Keep emergency numbers for doctors ambulance service hospital and fire department near your telephone INSPECT YOUR GENERATOR Be sure all covers guards and shields are in place Locate all operating controls and safety labels SERVICE GENERATOR SAFELY Before servicing your generator disconnect all plug wires and allow unit to cool down Service generator in a clean dry flat area If applicable block wheels to prevent unit from rolling WEAR PROTECTIVE CLOTHING Wear close fitting clothing and safety equipment appropriate to the job Prolonged exposure to loud noise can cause impairment or loss of hearing Wear a suitable hearing protective device such as earmuffs or earplugs to protect against objectionable or uncomfortable loud noises Operating equipment safely requires the full attention of the operator Do not wear radio or music headphones while operating equipment d e evans com mx 13 TROUBLE SHOOTING CHART NOISY GENERATOR CAUSE OF TROUBLE HOW TO CORRECT IT Replace damaged ball bearings and A u aa make sure they are adequately adjusted CAUSE OF TROUBLE Capacitor with excessive capacity CAUSE OF TROUBLE Capacitor with low capacity CAUSE OF TROUBLE Low speed when loaded Excessive load CAUSE OF TROUBLE CAUSE OF TROUBLE Defective receptacles Irregular engine speed Check engine carburation The reco
21. FORMATION 44 DANGER DANGER indicates a WARNING CAUTION WARNING indicates a CAUTION indicates a potentially potentially hazardous situation potentially hazardous situation hazardous situation which if not which if not avoided WILL which if not avoided could result avoided may result in minor or result in death or serious injury in death or serious injury moderate personal injury or property damage SAFETY AND OPERATION RULES Q To prevent accidental starting always remove the spark plug or cable from the spark plug before Read carefully and understand operator manual before maintaining the generator or engine operate this product Read and understand engine manual Units with broken or missing parts or without prior to operation Follow all warnings and instructions protective housing or covers should never know your equipment Consider the applications limitations be operated Contact your service center for and the potential hazards specific to your unit replacement parts Equipment must be placed on a firm supporting surface Units should be not operated or stored in wet or Load must be kept within rating stated on generator damp conditions or highly conductive locations nameplate Overloading will damage the unit or shorten such as metal decking and steel work its life Engine not to be run at excessive speeds To operate an Keep the generator clean and free of oil and other engine
22. JECION P MOFLE PORTABATERIA TENSOR PORTABATERIA NOTA Algunas partes se muestran solo como ilustraci n y no estan disponibles como refacciones individuales ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO evans com mx 25 26 evans com mx PROBLEMAS QUE SE PUDIERAN PRESENTAR MOTOR RUIDOSO POSIBLE CAUSA ACCION CORRECTIVA Baleros desgastados o mal Reemplace los baleros da ados y ajustados aseg rese que est n bien ajustados TENSION DEMASIADO ALTA SIN CARGA POSIBLE CAUSA ACCION CORRECTIVA Velocidad excesiva Ajustar la velocidad ata POSIBLE CAUSA Velocidad demasiado baja Diodos dafiados maa POSIBLE CAUSA Velocidad muy baja en carga Carga demasiado elevada POSIBLE CAUSA Velocidad en carga demasiado Ajustar la velocidad elevada Las acciones correctivas recomendadas podrian requerir ser hechas por un t cnico calificado o un Centro de Servicio Autorizado ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO INFORMACION DE SEGURIDAD A ADVERTENCIA A ADVERTENCIA El mon xido de carbono es un gas inoloro incolore e insaboro que se presenta aunque usted no lo vea o huela producido por cualquier escape de motor Todo escape del motor contiene mon xido de carbono un gas mortal Respirar mon xido de carbono puede provocar dolor de cabeza mareos n useas confusi n y eventualmente la muerte RECONOCER LA INFORMACION DE SEGURIDAD Este es el s mbolo de alerta de seguridad Cuando
23. SIVO DEL ALTERNADOR M100LL 0 o3 Y ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO evans com mx 23 DIAGRAMA ELECTRICO G120 Lista de Materiales 6 45070212 Interruptor Termomag 2P 50A 1 _ B R Hor metro 45090506 Recept culo 5 20R D plex Dec 22016 45090402 Recept culo L14 30R Eg 15490503 Puente P Tierra 21 45120103 Hor metroDigital 1 Lo dq EY Volt metro 220 127 Vca Q DIAGRAMA ELECTRICO DEL MOTOR Oil Warning Lamp Luz de presion de aceite Oil Pressure Switch Switch de presion de aceite z A Yellow Ignition Coils Nn Bobinas de Encendido T J Af y 2 A MEN M UN 3 L m Blac White B M T Spark Plug 8 Electric Starter Ground Con Bujias y Black Arrancador Electricd Tierra w Q Key Switch s Llave de Encendido Yellow Battery Regulat Charge Coil eerie na Bateria Bobina de Carga M Qu NS DY ou o u 2 gt S S lo V evans com mx ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO Green 24 DIBUJO EXPLOSIVO DEL GENERADOR LISTA DE MATERIALES TEM C DIGO DESCRIPCI N CANT 6 15170154 DEFLECTOR DE CALOR TANQUE COMBUSTIBLE 8 65080211 10X3 EJE 5 8 R AMARILLO 9 15200153 EJEP RUEDACORTO 5 8 MOFLE MOTOR 25 0 HP MULTIPLE THUNDER SOPORTE DE SU
24. ada para arrancar al equipo GLos watts unitarios del generador deber an coincidir o superar el n mero de watts que requiere el equipo que usted desea arrancar La potencia continua del generador disminuye de acuerdo a la temperatura y la altitud del lugar donde se ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO est usando utilice la tabla de correcci n de potencia y multiplique el factor de correcci n por la potencia nominal indicada en la hoja de especificaciones Y Siempre conecte la carga m s grande primero y luego agregue los dem s equipos uno por uno REQUERIMIENTO DE VOLTAJE Se deber de utilizar un acondicionador regulador de l nea cuando se operen uno o m s de los siguientes equipos de estado s lido Control para abrir la cochera o garaje Equipos de cocina con visualizaci n digital Televisores PRECAUCION de todos los equipos electr nicos deben comprobarse antes de enchufarlos a este generador Pueden ocurrir da os si el equipo no est dise ado para operar dentro de una variaci n de voltaje de 1096 y una variaci n Los requerimientos de voltaje y frecuencia operativa de frecuencia de 3 Hz de los valores nominales que aparecen en la placa de datos de el generador A fin de evitar da os siempre tenga una carga adicional no de estado s lido enchufada al generador en caso de usarse solamente equipos de estado s lido tales como un aparato de televisi n Tambi n p
25. at excessive speeds increases the hazard of personal foreign matter injury Do not tamper with parts which may increase or decrease the governed speed evans com mx Extension cords power cords and all electrical equipment must be in good conditions Never operate electrical ae with damaged or defective cords SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Store the generator in a well ventilated area with the fuel tank empty Fuel shall not be stored near the generator 12 Your generator should never be operated under these conditions Uncontrolled change in engine speed Electrical output loss Overheating in connected equipment e Sparking e Damaged receptacles Engine starting failure Excessive vibration Flame or smoke Enclosed compartment Rain or inclement weather Do not let the unit get wet when operating Check the fuel system periodically for leaks or signs of deteriorations such as chafed or spongy hose loose or missing clamps or damaged tank or cap All defects should be corrected before operation The generator should be operated serviced and refueled under the follow Conditions a Start and run the generator outdoors Do not run the generator in an enclosed area even if doors or windows are open avoid areas where vapors may be trapped such as pits garages cellars excavations etc D generator from site to site Improper lifting techniques may result in personal i
26. cargas Cuando la carga aumenta debe de utilizarse una extensi n de cable de calibre mayor Utilizar extensiones de calibre inadecuado puede causar serios problemas con el voltaje dando como resultado una p rdida de energia y el da o de las herramientas Cuanto m s peque o es el n mero del calibre del cable mayor es la capacidad de conducci n Un cable calibre 14 por ejemplo puede conducir una corriente m s alta que un calibre 16 Cuando hay varias extensiones conectadas debe de revisarse que cada extensi n sea del calibre m nimo de cable requerido Si se utiliza una extensi n con salidas para m s de una herramienta sume los amperes de placa de datos de cada una de las herramientas para determinar el tama o m nimo del calibre del cable de la extensi n Las extensiones para salidas a 127 volts son de 3 conductores donde el conductor verde es el cable de tierra el conductor blanco es la conexi n al neutro del generador y el conductor negro es el cable vivo Las extensiones para salidas de 127 220 son de 5 conductores donde el conductor verde es el cable de tierra el conductor blanco es la conexi n al neutro del generador y los conductores amarillos son los vivos DESEMPAQUE Cuando desempaque el generador aseg rese de que todas las piezas esten completas vea la secci n de Explosivo de Partes y Listado de Partes que est n al final de este manual Si alguna de las piezas no est o se encuentra en mal es
27. de bater as operan con un nivel de voltaje mayor lo que da ar a el sistema electr nico de inyecci n PRECAUCION opere el generador con un nivel bajo de combustible equipo de inyecci n se da a si el equipo trata de iue Sin combustible ARRANQUE DEL GENERADOR PRECAUCION Este producto contiene o produce quimicos cuando es utilizado conocidos por el estado de California como causantes de c ncer defectos de nacimiento y otros da os severos California C digo de Salud y Seguridad 25249 5 et seq carbono un gas mortal Respirar mon xido de carbono puede provocar dolor de cabeza mareos nauseas confusi n y eventualmente la muerte El mon xido de carbono es un gas letal inodoro e invisible Que se puede presentar aunque usted no vea o huela ning n escape de motor Niveles mortales de mon xido de carbono se pueden acumular r pidamente y usted puede perder habilidad para salvarse Tambi n niveles mortales del mon xido de carbono pueden guardarse por horas o d as en reas cerradas o con poca ventilaci n Si usted experimenta cualquier sintoma de envenenamiento obtenga aire fresco y busque ayuda m dica Para prevenir da os serios o la muerte por mon xido de carbono NUNCA encienda motores en interiores Aunque trate de ventilar el escape de la m quina con ventiladores ventanas o puertas abiertas el mon xido de carbono r pidamente puede alcanzar niveles peligrosos NUNCA encienda motores
28. e a flat surface and far from flamables materials Do not allow the generator gets wet Fill the tank fuel outdoors up to 6 0 gallon of gasoline do not fill the tank up to the top of tank After removing the plug with dipstick located in one side of the engine fill with 1 2 liter of oil Fill with SAE 30 oil Use a funnel to avoid the spill of the oil Review the oil level by means of the dipstick it must mark Full Place the plug with plastic dipstick carefully to avoid damage of the threads O Before connecting the equipment to the generator review that the equipment is Off Read the section DETERMINING TOTAL WATTAGE Do not overload the generator Calculate the total power of the equipment The maximum power of the generator is indicated in the specification sheet GENERATOR ELECTRIC CONTROLS amp OUTLETS WARNING A replace facility power in times of outages the facility power input must be isolated Refer to the Electric Generator Safety Precautions These connections must only be made by a licensed electrician L replace tac If the Generator will be used to SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE A CAUTION A CAUTION Do not connect a battery charger to the generator Battery chargers operate with a higher DC voltage and this could damage the Electronic Fuel Injection System A CAUTION A CAUTION Do not operate the generator with a low fuel level The EFI system could damage if the equi
29. eda afectar que el generador opere de manera segura Si se escucha un ruido extra o o alguna vibracion anormal apague el generador imediatamente o Aseg rese de arreglar ese problema antes de darle m s uso No utilice el equipo da ado evans com mx 22 9 Inspeccione peri dicamente todas las tuercas y tonillos que se encuentren en su lugar y apretados Q Guarde su equipo en un lugar limpio y seco Para el mejor mantenimiento del motor y cualquier otro problema acuda al manual de propietario del motor Despu s de que el motor se haya enfriado remueva la gasolina excedente y almac nela en un recipiente seguro y aprobado para tal fin Q las primeras 20 horas de uso del generador drene y reemplace el aceite del motor despu s de eso el aceite debe de ser cambiado cada 100 horas de trabajo DEFLECTOR DE CALOR Inspecci nelo para asegurarse de que el deflector de calor est intacto y en su lugar No retire ni modifique ninguna pieza Retirar o modificar estas piezas puede causar da os serios a la unidad MOTOR Congelamiento del carburador Durante los meses de invierno podr an desarrollarse condiciones atmosf ricas poco usuales que causen una condici n de congelamiento en el carburador Si esto ocurre el motor podr a funcionar mal perder potencia y detenerse Para obtener mas informaci n llame al Centro de Servicio NOTA Consulte el manual de fabricante del motor para su servicio y mantenimiento CONS
30. en reas poco ventiladas o parcialmente cerradas Areas como bodegas cocheras s tanos viviendas habitaciones etc NUNCA encienda motores afuera cuando los gases del escape del motor puedan introducirse en construcciones por aberturas como ventanas o puertas 5 Todo escape de motor contiene mon xido de ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO La gasolina es muy peligrosa Si la gasolina hace contacto con superficies calientes puede ocasionar lesiones serias o la muerte 1 No llene el tanque de combustible con el motor en marcha 2 Apague su motor y espere 2 minutos antes de llenarlo de combustible 3 No derrame combustible al volver a llenar el tanque 4 No mezcle aceite con gasolina 5 Siga las instrucciones y advertencias contenidas en el manual de motor PRECAUCIONES ANTES DE ARRANCAR Antes de arrancar el generador verifique si hay piezas sueltas o faltantes y si hay cualquier tipo de da o que pudiera haber ocurrido durante el envi Este generador no debe operase sin tener colocado el deflector contra el calor instalado de f brica Si no se hace sto podr a recalentarse el tanque de combustible pudiendo ocurrir un incendio que cause lesiones personales ARRANQUE DEL MOTOR Revise el nivel de aceite Desconecte todas las cargas el ctricas de la unidad Abra la v lvula de cierre de combustible Si el motor esta fr o mueva la palanca del ahogador hacia la derecha MN el interr
31. he engine and wait 2 minutes before filling the tank 3 Do not spill fuel while refilling tank 4 Do not mix oil with gasoline 5 Follow all the instructions and warnings in the engine manual evans com mx 7 PRE START PREPARATION Before starting the generator check for loose or missing parts and for any damage which may have occurred during shipment A WARNING A WARNING This generator must not be operated without heat shield installed in factory Failure to comply may cause the fuel tank to overheat an result in personal injury from fire Check the oil level and fuel Disconnect all electrical loads from the unit Open fuel shut off valve Adjust choke as necessary Set the engine switch to the ON position Pull on the starter rope with fast steady pull As the engine warms up readjust the choke On electrical start models turn the key switch to START Release key switch after the engine start DANGER Provide adequate ventilation for toxic exhaust k gases and cooling air flow e Do not start or run the generator in an enclosed area even if doors or windows are open e Engines operation produces carbon monoxide odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death CAUTION Allow generator to run at no load for five minutes after each initial start up to permit engine and generator to stabilize APPLYING LOAD This unit ha
32. ida Volt metro 120 240 VAC PREPARACION E INSTALACION DEL GENERADOR Coloque el generador al aire libre en donde ser utilizado Esto debe de ser en una superficie plana y lejos de materiales flamables No permita que el generador se moje O Llene el dep sito de combustible al aire libre hasta 21 litros de gasolina no llene el tanque hasta el tope E Agregue 1 2 litros de aceite al motor quitando la bayoneta que se localiza a un lado del motor Utilice aceite SAE 30 Utilice un embudo para evitar el derrame de aceite Revisar el nivel de aceite con una bayoneta esta debe marcar lleno Coloque cuidadosamente el tap n de aceite para evitar que los hilos de la rosca se da en O Antes de conectar los equipos al generador revise que se encuentren en posici n de apagado Vaya a la secci n COMO DETERMINAR LA POTENCIA No sobrecargue el generador Calcule la potencia total de los equipos La potencia m xima del generador est indicada en la hoja de especificaciones ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO ADVERTENCIA A Si el generador va a ser utilizado para sustituir Gereg en pocas de interrupciones la entrada de energ a debe ser aislada Refi rase a las medidas de seguridad el ctricas del generador en la secci n INSTALACION Estas conexiones se deben hacer olamente por un electricista calificado A PRECAUCION No conecte un cargador de bater as al generador Los cargadores
33. in blocks of wood to a sufficient height that allows the assembly of the rim and place the spacing rings on both sides 4 Insert both wheels on the axle and secure with pins FRONT SUPPORT INSTALLATION Place the generator without tires on wooden blocks allowing a place to install the front support O Attach the front support to the frame with screws evans com mx BATTERY INSTALLATION CAUTION Before installing the battery remove the key from the Control Panel of your generator 1 Set the battery holder on the frame and secure it with the screw washer and nut as shown in the drawing Place the battery on the battery holder Secure the battery using the brackets attach on the battery holder O Identify the red and black wires with positive and negative electrodes of the battery Connect the red wire to the positive terminal of the battery and the black wire to the negative terminal See Fig Handle the battery carefully as it contains highly corrosive acid and can cause burns Never connect the red wire to black this can cause damage to physical integrity and the equipment Dipstick SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE CONTROL PANEL NN OT Ty Enegia para la Vida G120 PRO Key switch Www PANE do mx MX Surge GENERATOR SET UP AND CABLE CONNECTIONS 1 Place the generator outdoors where it will be used This must b
34. ire del retr ctil varias veces y coloque la buj a Luego tire del arrancador hasta que sienta que el pist n est en su carrera de compresi n y d jelo en esta posici n Esto cierra las v lvulas de entrada y escape para evitar que el interior del cilindro se oxide Cubra la unidad y almac nela en un lugar limpio y seco con buena ventilaci n y lejos de chispas o llamas NOTA Recomendamos que siempre utilice un ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO estabilizador para combustible Un estabilizador de combustible minimizar la formaci n de dep sitos de ALTERNADOR M100LL goma de combustible durante el almacenamiento El estabilizador de combustible puede agregarse a la REF DESCRIPCI N gasolina en el tanque de combustible o junto con la gasolina en un contenedor de almacenamiento 3 Brida d lamient 1 LEA CUIDADOSAMENTE 3 Bridadeacoplamiento Le E wma 3 EL FABRICANTE Y O DISTRIBUIDOR HA 1 PROPORCIONADO EL DIAGRAMA DE PARTES EN EN ESTE MANUAL COMO HERRAMIENTA DE REFERENCIA SOLAMENTE NI EL FABRICANTE Y O DISTRIBUIDOR ETUDES A REPRESENTA O DA GARANTIA AL COMPRADOR 8 Puenterectificador 1 DE QUE STE EST CALIFICADO PARA HACER REEMPLAZO DE PIEZAS DE ESTE PRODUCTO Birlo de apriete DE HECHO EL FABRICANTE Y O DISTRIBUIDOR EXPRESAN QUE TODAS LAS REPARACIONES Y PERSONA CON LICENCIA Y CERTIFICADA Y NO POR EL COMPRADOR REEMPLAZO DE PIEZAS DE LA INSTALACION DE x NONE 48 1 DIBUJO EXPLO
35. izer will minimize the formation of fuel gum deposits during storage The fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in a storage container ENGINE WIRING DIAGRAM Oil Warning Lamp Luz de presion de aceite Oil Pressure Switch Switch de presion de aceite lt A Yellow a Ignition Coils Bobinas de Encendido Af S LJ S A H 3 e L Blac White M gt Spark Plug O Electric Starter Con e Bujias y Black Arrancador x nie Tierra L A Q Key Switch 52 Llave de Encendido ix v9 gt 0 Yellow S B Battery Charge Coil Four I Bateria Bobina de Carga Regulador gt CES QE NS 5 7 A TH D S 2 J uu SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Green evans com mx 9 G120 WIRING DIAGRAM Hourmeter 220 Vac Tt A F Voltmeter 220 127 Vac eee See eee aeo amc e am m m w m m m s w Cum u cmm cun s m w m Bill of Materials Item ant A able Hose 3 4 27cm 45070212 Thermomag Switch 2P 50A un o e e e e I C A mn m o un C 15411883 Breaker Support 2P 45110201 Voltmeter 0 300 VAC 30080101 Toggle Switch 2P 2T Y N Y E F Receptacle 5 20R D plex Receptacle L14 30R E H eS Wm
36. l ctricos locales aplicables El uso apropiado requiere la instalaci n de un interruptor de transferencia de doble tiro por un electricista capacitado y calificado para asegurar que los circuitos el ctricos del edificio puedan ser conmutados con seguridad entre el suministro el ctrico y la salida del generador evitando de este modo la retroalimentaci n hacia el sistema de suministro el ctrico FACTORES DE CORRECCION DE POTENCIA POR ALTITUD Y TEMPERATURA ALTITUD Metros 09 32 F 0 500 1000 3280 096 1500 2000 3000 9840 0 75 ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO TEMPERATURA 21 C 70 F 50 C 122 F 75 C 167 F 100 C 212 F on ose os os evans com mx 17 A ADVERTENCIA Para evitar la retroalimentaci n hacia los sistemas de suministro el ctrico se requiere el aislamiento del sistema el ctrico residencial Antes de realizar la conexi n temporal del generador al sistema el ctrico residencial apague el interruptor principal Antes de hacer las conexiones permanentes debe de instalarse un interruptor de transferencia de doble tiro Para evitar la electrocuci n o da os a la propiedad solo debe de ser un electricista calificado el que conecte el generador al sistema el ctrico residencial Las leyes de California requieren el aislamiento del sistema el ctrico residencial antes de conectar un generador a los sistemas el ctricos residenciales
37. lada ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO Q Nunca debe operarse una unidad con piezas quebradas o faltantes o sin el revestimiento o cubiertas protectoras Comun quese con su centro de servicio para solicitar los repuestos Las unidades no deben operarse ni almacenarse pA lugares h medos o mojados ni altamente conductores tales como plataformas met licas o estructuras de acero 10 Mantenga el generador limpio y libre de aceite barro o cualquier otro material extra o Los cordones de extensi n los cordones el ctricos y todos los equipos el ctricos deben estar en buenas condiciones Nunca opere un equipo el ctrico con cordones da ados o defectuosos Guarde el generador en un lugar con buena ventilaci n con el tanque de combustible vac o No se debe de almacenar combustible cerca del generador Su generador no deber operase jam s si ocurre lo siguiente evans com mx 15 Velocidad del motor fuera de control P rdida de carga el ctrica e Sobrecalentamiento de el equipo conectado Formaci n de chispas Recept culos da ados Fallo de encendido Vibraci n excesiva e Llamas o humo Compartimiento cerrado Lluvia o inclemencia del tiempo No permita que la unidad se moje cuando est funcionado 13 Verifique peri dicamente que no haya fugas o se ales de deterioro en el sistema de combustible como mangueras demasiado gastadas o blandas abrazaderas floja
38. mmended corrective actions may require to be made by a qualified technician or an Authorized Service Center REGLAS DE SEGURIDAD PELIGRO Ay ADVERTENCIA 4 PRECAUCION PELIGRO indica una situaci n ADVERTENCIA indica PRECAUCION indica una situaci n potencialmente peligrosa que si situaci n de peligro potencial potencialmente de riesgo la cual no se evita PROVOCAR muerte la cual si no se evita podr a si no se evita puede ocasionar o una lesi n seria ocasionar lesiones severas e heridas personales menores o moderadas o da os materiales 14 evans com mx SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5 5 5 ESPECIFICACIONES Tipo Frecuencia Potencia maxima Capacidad Voltaje Corriente maxima Regulacion de voltaje Tipo Modelo Marca Displazamiento Potencia maxima Combustible Tanque de combustible Consumo 75 Carga Consumo 100 Carga Capacidad de aceite Sistema de arranque Sensor de aceite Receptaculo monof sico duplex Receptaculo bif sico twist lock Interruptor principal proteccion de sobre corriente Voltimetro Horometro Nivel de ruido Estructura Accesorios Peso neto Dimensiones generales AnchoxLargoxAlto sin llantas ESPECIFICACIONES G120MG2200TH MONOFASICO 2 POLOS SIN ESCOBILLAS 60 Hz 12 000 WATTS 11 000 WATTS 240 120 V 50 100A DIODOS CON VARIOSTORES VENTILADO POR AIRE 4 TIEMPOS CILINDROS V TWIN OHV
39. njury To avoid burns do not touch engine muffler or other engine or generator surfaces which became hot during operation Do not alter or modify the heat shield D NOISE CAUTIONS The generator can produce high noise levels Prolonged exposure to noise levels above 85 dBA is a hazard to hearing Always wear ear protection when operating or working around the generator when it is running DEFINING TOTAL WATTAGE 1 In order to prevent overloading and possible damage to your generator it is necessary to know total wattage of the connected load To determine which load and or appliances your generator will run follow these steps Check wattage requirements by referring to the loads nameplate or by calculating it multiply amps x volts watts You can get help for calculation using the Table 1 Total the watts for each item If the nameplate only give volts and amps multiply volts x amps watts 1 kW 1 000 watts o Motorized appliances or tools require more than their rated wattage for start up NOTE Allow 2 gt 4 times the listed wattage for starting equipment powered by electric motors The generator s rated watts should match or exceed the total number of watts required for the equipment you want to run The altitude and temperature can modify the generator s ratings Use the Table 2 to calculate the generator s rating multiply the factor x rated output in the generator s specs when the condition is not at 21 C a
40. nnecting generator to residence electrical system Oi your generator is to be used as a stand by power To avoid back feeding into utility systems isolation of the residence electrical system is required Before temporary connection of the generator to the e system turn off the main service disconnecting evice BEFORE OPERATION SROUNDING THE GENERATOR The National Electric Code requires that this product be source in case of utility power failure it should be installed by a registered electrician and in compliance with all applicable local electrical codes Proper use requires that a double throw transfer switch be installed by licensed qualified electrician so that the building s electrical circuits may be safely switched between utility power and the generator output thereby preventing back feed into the power utility s electrical system Always follow local codes and regulations that apply to the installation of any item that concerns this product 1 NFPA 70 National Electrical Code 2 NFPA 37 Standard for Installation and Use of Stationary Combustible Engines 3 Agricultural Wiring handbook of Farm Standby Electric Power TABLE 2 properly connected to appropriate earth ground to help prevent electric shock A ground terminal connected to the frame of the generator has been provided for this purpose Connect a length of a heavy gauge 12 AWG min bare cooper cable between the ground lug
41. nual If any parts are missing or broken please call our distributor RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT Double Insulated Canadian Standards Association NON Underwriters Laboratories Inc Volts Alternating Current A es n f O xxx min No Load Revolutions per Minute RPM E SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE NAMEPLATE AMPERES At Full Load EXTENSION CORD LENGTH Feet Feet Feet Feet Feet 0 2 0 18 18 18 18 16 2 1 3 4 3 5 5 0 5 1 7 0 7 1 12 0 12 1 16 0 16 1 20 0 Based on limiting the line voltage drop to five volts at 15096 of the rated amperes evans com mx 5 ASSEMBLY INSTRUCTIONS Before starting your generator you must install the following components Handles wheel kit and battery holder battery is not included HANDLE INSTALLATION Unpack and inspect all parts to see if there are not missing or defective parts Find the 2 handles the bolts and the pins Attach the handle to the frame using the holes to set the handles Insert the bolt to hold the handle to the frame Set the pin in the bolt hole Repeat operations 3 4 and 5 for the next handle WHEEL INSTALLATIO Before mounting the wheels make sure they are inflated to a pressure between 15 psi and 20 psi not exceeding 24 psi as this could cause damage to you Insert the shaft to the base through the hubs of the frame Support the generator
42. odr a resultar necesario un regulador de l nea el ctrica para algunas aplicaciones de equipo de estado s lido Est reos Computadoras personales Relojes de cuarzo M quinas fotocopiadoras Equipo telef nico INSTALACION 4h ADVERTENCIA Para evitar posibles lesiones f sicas o da os materiales es necesario que la instalaci n y todo el servicio sea realizado por un electricista profesional o representante de servicio autorizado Bajo ninguna circunstancia debe permitirse que una persona que no est capacitada trate de manipular cables dentro del circuito de la compafi a suministradora del servicio el ctrico PROMEDIOS ESTIMADOS WATTS EQUIPO WATTS EQUIPO WATTS Acondicionador de aire Lavadora Incubadora de pollos 100 Cafetera 400 700 Television 200 500 Taladro el ctrico chico Taladro el ctrico grande Plancha para alimentos 1 000 2 000 Plancha 1 500 2 500 Secadora de ropa L mpara TABLA 2 O Para evitar la retroalimentaci n a los sistemas de suministro se requiere el aislamiento del sistema el ctrico residencial Antes de realizar la conexi n temporal del generador hacia el sistema el ctrico residencial apague o desconecte el servicio principal si el generador va usarse como fuente de energ a de reserva en caso de un fallo del suministro el ctrico debe de ser instalado por un electricista calificado de acuerdo con todos los c digos e
43. pment doesn t have enough fuel A CAUTION A CAUTION This product contains or 29 produces chemicals when it is used known by the Californian state that cause cancer severe birth defects or other damages Californian Code of Health and Security 25249 5 et All engines exhaust carbon monoxide a deadly gas Breathing carbon monoxide can cause headaches dizziness nausea confusion and eventually death The carbon monoxide is colorless odorless tasteless gas which may be present even if you do not see or smell any engine exhaust Deadly levels of carbon monoxide can lay for hours or day in inclosed or poorly ventilated areas If you experience any symptoms of carbon monoxide poisoning leave the area immediately get fresh air and SEEK MEDICAL TREATMENT To prevent serious injury or death from carbon monoxide NEVER run engine indoors Even if you try to ventilate engine exhaust with fans or open windows and doors carbon monoxide can rapidly reach dangerous levels NEVER run engine in poorly ventilated or partially enclosed areas such as barns garages basements carports under dwellings or pits NEVER run engines outdoors where engine exhaust can be dawn into a building through openings such as windows and doors A WARNING WARNING Gasoline is very dangerous Qro injury or death may result from fire caused by gasoline contacting hot surfaces 1 Do not fill the fuel tank with the engine running 2 Turn off t
44. que de gasolina NO llene demasiado el tanque Prevenga incendios manteniendo el producto limpio de basura acumulada grasa y residuos Siempre limpie el combustible derramado ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO SIGA LAS INSTRUCCIONES DE SEGURIDAD Lea atentamente todos los mensajes de seguridad en este manual y en las se ales de seguridad del producto Mantenga las se ales de seguridad en buen estado Reemplacelas si est n da adas Aseg rese de que los componentes de productos nuevos y piezas de reparaci n incluyan las se ales de seguridad Aprenda a utilizar el producto y c mo usar los controles adecuadamente No deje que nadie opere sin haber leido y entendido las instrucciones Mantenga el producto en buenas condiciones de funcionamiento Las modificaciones no autorizadas al producto puede afectar la funci n y o seguridad y afecta la vida del producto Si no entiende alguna parte de este manual y necesita ayuda comun quese con su distribuidor VACIE EL TANQUE DE GASOLINA CUANDO ALMACENE SU GENERADOR La gasolina almacenada en el tanque de combustible puede explotar Nunca almacene el producto con la gasolina en el tanque dentro de un edificio donde los gases pueden alcanzar una llama o chispa Siempre drene la gasolina deltanque de combustible y el recipiente del carburador al almacenar su producto Deje que el motor se enfr e antes de guardarla PREPARESE PARA LAS EM
45. rrecta Mover la velocidad del motor le har perder la garant a PRECAUCION A Al aplicar una carga no exceda la potencia nominal maxima del generador al usar uno o m s recept culos Adem s no exceda el amperaje nominal de ning n recept culo APAGADO DEL GENERADOR Retire toda la carga el ctrica Deje que el motor funcione por unos minutos sin carga Mueva la llave del motor a la posici n OFF Haga girar la llave a OFF en los modelos de encendido el ctrico No abandone el generador hasta que ya haya sido detenido por completo o Cierre la v lvula de paso del combustible si el motor debe colocarse en dep sito o en transporte Si le va a colocar una cubierta espere hasta que la unidad se haya enfriado ARRANQUE INICIAL Un procedimiento de arranque inicial controlado ayuda a asegurar una operaci n correcta del motor y del generador Siga el procedimiento para el motor descrito en el manual de motor PRECAUCION A No aplique una carga el ctrica fuerte durante el periodo inicial de funcionamiento las primeras 2 0 3 horas de operacion MANTENIMIENTO ATENCION Desconecte todos los enchufes o clavijas del panel y el cable de la bujia si el motor es de arranque electrico antes de cualquier inspecci n de mantenimiento Antes de cada uso revise las condiciones generales del generador revise que todas las piezas est n alineadas completas revise si hay cables da ados o alguna otra condici n que pu
46. rsonales Cu Para evitar que j toqu ilenciador del motor u otras superficies del generador que se hayan calentado durante la operaci n No modifique el deflector de calor e PRECAUCIONES DE RUIDO El generador puede producir elevados niveles de sonido un nivel de sonido prolongado arriba de 85 dB es da ino para el o do Utilice protecci n para los o dos cuando est operando alrededor del generador mientras est encendido COMO DETERMINAR LA POTENCIA A fin de evitar la sobrecarga y los posibles da os a su generador resulta necesario conocer la potencia total de la carga conectada Para determinar a qu herramientas y o equipos electrodom sticos su generador har funcionar siga los pasos a continuaci n Determine si desea hacer funcionar un aparato o varios aparatos simult neamente O Verifique los requerimientos de potencia de arranque y de funcionamiento de los aparatos fij ndose en la carga especificada en la etiqueta o ay dese utilizando los valores de la Tabla 1 o calcul ndola multiplique volts x amperes E Sume la potencia necesaria de arranque y de funcionamiento de cada aparato Si la etiqueta solo le da el voltaje y el amperaje entonces multiplique volts x ampes watts 1kW 1 000 watts Los electrodom sticos o las herramientas impulsadas por motores requieren m s potencia que lo especificado en su placa de datos para arrancar NOTA Considere 2 7 gt 4 veces la potencia marc
47. s been pretested and adjusted to handle its full capacity When starting the generator disconnect all loads Apply load only after the generator is running Voltage is regulated via the engine speed adjusted al the factory for correct output Readjusting will void warranty A CAUTION A When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any receptacle evans com mx SHUTTING THE GENERATOR OFF Remove entire electrical load Let the engine run for a few minutes with no load Move the engine switch to the OFF position turn the key switch to OFF on the electrical start models Qoo not leave the generator until it has been completely stopped O Close the fuel shut off valve if the engine is to be put in storage or transported Qi cover is used do not install it untill the generator is cool INITIAL START PROCEDURE Controlled initial start helps insurance of proper engine and generator operation Follow engine start procedure outlined in engine manual A CAUTION A Do not apply a heavy electrical load during start period the first two to three hours of operation MAINTENANCE ATTENTION Disconnect all plugs from the panel and the cable of the spark plug if the motor is of electrical starting before any inspection for maintenance Before each use review the general conditions for the
48. s o faltantes o tanque o tap n da ados Todos estos defectos deber n corregirse antes de la operaci n El generador debe operarse recibir servicio y rellenarse de combustible solamente en las siguientes condiciones Encienda y ponga a funcionar el generador al aire libre No ponga a funcionar el generador en un rea cerrada aun cuando las puertas o ventanas se encuentren abiertas evite reas donde los gases de escape puedan encerrarse tales como pozos garajes s tanos excavaciones y galer as PELIGRO RIESGO DE MONOXIDO DE CARBONO Los gases del escape del motor contienen mon xido de carbono un gas letal inodoro invisible que si se inhala puede provocar la muerte o una lesi n personal seria Si comienza a sentirse indispuesto mareado o d bil mientras utiliza el generador ap guelo e inmediatamente vaya a un lugar fresco podr a padecer de envenenamiento por mon xido de carbono Buena ventilaci n para el enfriamiento La circulaci n de aire y las temperaturas son importantes para las unidades enfriadas por aire Las temperaturas no deber n exceder 40 C 104 F de temperatura ambiente Rellene de combustible al generador en un rea bien iluminada Evite el derrame de combustible y nunca rellene con combustible mientras el generador est funcionando Antes de rellenar combustible espere que el motor se enfr e durante 2 minutos No eche combustible cerca de llamas luces piloto o equipos el
49. t may possibly damage equipment do not allow engine to run out of fuel when electrical loads are applied 400 700 200 500 2 er et dbi d du Line Electric drill small 225 1 000 Toaster 900 1700 am o C 500 1000 Vaccum cleaner 200 300 to the equipment Electric drill large 500 1 000 Vaccum cleaner 200 300 Do not stick anything through ventilating slots even Fan 40 200 Water pump 1 000 3 000 e when the generator is not operating This can damage Freezer 300 500 Water heater 1 000 5 000 the generator or cause personal injury or emelinand su pogo one Before transporting the generator in a vehicle drain all A fuel to prevent leakage that may occur Iron 900 1 500 Large hand saw 1 500 2 500 Use proper lifting techniques when transporting the Light bulb TABLE 1 POWER USAGE WATTS WATTS LOAD DEVICE WATTS Chicken incubator Skillet Portable heater Air conditioner Clothes dryer Coffe maker Hot plate SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE evans com mx 3 CAUTION A AUTION Operating voltage and frequency requirements of all electronic equipment should be checked prior plugging them into this generator Damage may result if the equipment is not designed to operate within 10 of voltage and 3 Hz of the rated values marked in the generator s nameplate To avoid damage always have an additional no solid state load plugged into
50. t the sea level Always connect first to the generator the heaviest load and then add other items one at a time DANGER CARBON MONOXIDE HAZARD the engine exhaust contains carbon monoxide a poisonous odorless invisible gas which if breathed may cause death or serious personal injury If you start to feel sick dizzy or weak while using the generator shut it off and get to fresh air right away you may have carbon monoxide poisoning b Good ventilation for cooling Air flow and temperatures are important for air cooled units Temperatures should not exceed 104 F ambient 40 C c Refuel the generator in a well lighted area Avoid fuel spills and never refuel while the generator is running Allow engine to cool for two minute prior to refueling d Do not refuel near open flames pilot lights or Sparking electrical equipment such a power tools welders and grinders e The muffler and cleaner must be installed and kept in good condition at all times as they function as flame arrest if backfiring occurs f Do not smoke near the generator Ensure that generator is properly grounded see Grounding the Generator section in this manual Do not wear loose clothing jewelry or anything that 16 maybe caught in the alternator Or other rotating TY parts LOAD DEVICE T Unit must reach operating speed before p electrical loads are connected Disconnect loads before Automatic Washer turning off engine To prevent surging tha
51. tado por favor dir jase a nuestro distribuidor lo m s pronto posible ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO AMPERAJE DE LA PLACA a plena carga A CALIBRE DE CABLE MINIMO RECOMENDADO PARA EXTENSIONES 120 VOLTS LARGO DE LA EXTENSION INSTRUCCIONES DE ENSAMBLE Antes de arrancar su generador debe instalar los siguientes componentes Kit de llantas soporte de bater a no incluida Mofle y Manijas INSTALACION DE MANIJAS Desempaque y revise todas las partes para ver si no vienen defectuosas o falta alguna de ellas Localice las dos manijas dos pernos y 2 chavetas Fije la manija en la base utilizando como posici n los barrenos de la base Inserte el perno para sujetar la manija con la base Coloque la chaveta en el barreno del perno Repita las operaciones 3 4 y 5 para la siguiente manija m A mmm A ae A GO OOO fl pa e ku i PE rr eH INSTALACION DE RUEDAS Antes de montar las ruedas aseg rese que esten infladas a una presi n entre15 psi y 20 psi no exceda las 24 psi ya que esto podr a causarle da os fisicos Inserte el eje a la base a traves de los bujes de la base Apoye el generador en blocks de madera a una altura suficiente que le permita el montaje de las llanta colque 2 anillos separadores a ambos lados Inserte ambas llantas en el eje y aseg relas con las chavetas 5 evans com mx 19 INST DE SOPORTE FRONT
52. the generator if only solid state equipment such as a television set is used A power line conditioner is recommended for some solid state applications A power line conditioner should be used when running one or more of the following solid state items Garage door openers Kitchen appliances with digital displays Televisions e Stereos Personal computers Quartz clocks Copy machines Telephone equipment Other solid state equipment may require a power line conditioner for more information contact customer Service INSTALLATION WARNING WARNING To avoid possible personal injury or equipment damage a register electrician or an authorized service representative should perform installation and all service Under no circumstances should an unqualified person attempt to wire into utility circuit Give the generator at least two feet of space from any nearby wall to dissipate heat WARNING A WARNING To avoid back feeding into utility system isolation of the residence electrical system is required Before temporary connection of a generator to the residence electrical system turn off the main switch Before making permanent connections a double throw transfer switch must be installed To avoid electrocution or property damage only a trained electrician should connect generator to residence electrical system California law requires isolation of the residence electrical system before co
53. uptor de apagado encendido a la posici n ON Jale la cuerda del retr ctil del motor si es de arranque manual de un tiron r pido y parejo o gire la llave de switch d encendido si es de arranque el ctrico lleve la llave a la posici n de START y posteriormente suelte la llave despu s que arranque el motor Despu s del arranque regrese la palanca del ahogador a su posici n original hacia la izquierda A PELIGRO Debe suministrar una ventilaci n adecuada para los gases t xicos de escape y el flujo de aire que enfria al motor el motor es enfriado por aire que es inyectado por su propio ventilador No encienda o arranque el generador en un rea cerrada incluso si las puertas o ventanas est n abiertas El motor despide mon xido de carbono un gas venenoso inodoro e invisible e Aspirar mon xido de carbono puede ocasionar nausea desfallecimiento o la muerte evans com mx 21 PRECAUCION Permita que el generador funcione sin carga durante cinco minutos despu s de cada arranque inicial para permitir que se estabilicen el motor y el generador COMO APLICAR UNA CARGA Esta unidad ha sido previamente verificada y ajustada para manejar su capacidad m xima Al arrancar el generador desconecte todas las cargas Aplique la carga solamente despu s de que el generador est funcionando El voltaje se regula por medio de la velocidad del motor ajustada en f brica para la salida co
Download Pdf Manuals
Related Search
Related Contents
Vieta VHP-SB200BK User's Manual USER MANUAL - Kramer Electronics Focal Little Bird Pack 2.1 User Manual VirtuaX RDMODGSM-TV Roger と人工内耳 メドエル社 RONDO / OPUS スタンダード型 / DUET2 Troy-Bilt Electric Snow Thrower Flurry 1400 User's Manual owner`s manual - ims office Moule à pâtisserie spécial Noël Genome-CRISP™ CRISPR-Cas9 Products and Copyright © All rights reserved.