Home
CONTENTS: SPECIFICATIONS
Contents
1. BEFORE USING THIS KIT READ THIS MANUAL COMPLETELY AND THOROUGHLY UNDERSTAND ITS OPERATING PROCEDURES SAFETY WARNINGS AND MAINTENANCE REQUIREMENTS It is the responsibility of the kit owner to make sure all personnel read this manual prior to using the kit It is also the responsibility of the kit owner to keep this manual intact and in a convenient location for all to see and read If the manual or product labels are lost or not legible contact Sunex for replacements If the operator is not fluent in English the product and safety instructions shall be read to and discussed with the operator in the operator s native language by the purchaser owner or his designee making sure the operator comprehends its contents 4910B 4 09 29 11 O S U N E X MODEL 4910B CAPACITY 10 TON o T O O LS PORTABLE RAM KIT LIMITED WARRANTY SUNEX INTERNATIONAL INC WARRANTS TO ITS CUSTOMERS THAT THE COMPANY S SUNEX TOOLSO BRANDED PRODUCTS ARE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS Sunex International Inc will repair or replace its Sunex Tools branded products which fail to give satisfactory service due to defective workmanship or materials based upon the terms and conditions of the following described warranty plans attributed to that specific product This product carries a ONE YEAR warranty During this warranty period Sunex Tools will repair or replace at our option any part or unit which proves to be defective in material or workman
2. Item Part Description Quantity Item Part Description Quantity A RS10TP Pump Incl Hose 1 03 RS10T03 Flat Base 1 B RSHS Hose 1 04 RS10T04A Ram Toe 1 C RS10TR Ram 1 05 RS10T05 Plunger Toe 1 D RSSPR Spreader 1 06 RS10T06 Wedge Head 1 01 RS10T01 Case 1 07 RS10T07 V Base 1 RS10TO1WH Wheel w Hardware for Case 2 08 RS10T08 Male Connector 1 02 1 RS10T02 1 4 33 110mm Extension 1 09 RS10T09 Serrated Saddle 1 02 2 RS10T02 2 10 43 265mm Extension 1 10 RS10T10 Rubber Head 1 02 3 RS10T02 3 14 37 865mm Extension 1 11 RSPG Pressure Gauge 1 02 4 RS10T02 4 20 47 520mm Extension 1 4910B 6 09 29 11 RS10TP 10 TON PUMP PARTS LIST AND DRAWING P10 P09 lt P11 Item Part 8 do P12 Description Quantity Item MODEL 4910B CAPACITY 10 TON PORTABLE RAM KIT Quantity PO PO2 PO3 P04 PO5 PO6 PO7 PO8 P09 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P24 P25 P26 P27 P28 Items identified by an asterisk are available in pump seal kit RSPSKA RSPO9A RSP12 RSP15 RSHS RSP17 RSP18 Valve Block Oil Filter 0 Ring Reservoir Tie Rod Nylon Ring Oil Filler Screw Sealing Breather Valve Incl 6 9 Screw 0 Ring Pump Foot Ball 0 Ring Release Valve Hydraulic Hose Coupler Hose Dust Cover Ball Ball Cap Spring Screw 0 Ring Screw Screw Protector Nylon Ring Valve Base Valve Cover E AN N DO
3. Items identified by an asterisk are available in Spreader Seal Kit RSSPRSK NOTE Items which are not identified by a part number or with an asterisk are not available separately 4910B 8 09 29 11 O S U N E X MODEL 4910B CAPACIDAD 10 TON o T O O L S EQUIPO PORT TIL DE PISTONES MANUAL DE OPERATI N CONTENIDO P gina 9 Especificaciones 10 Informaci n de advertencia 11 12 Ensamble operaci n y mantenimiento 13 Diagn stico de aver as e informaci n de garant a ESPECIFICACIONES Capacidad 10 Ton 7 250 psi Altura m nima del pist n 322mm 12 68 Recorrido 130mm 5 12 Capacidad fluida 4910B 9 09 29 11 O S U N E X MODEL 4910B CAPACIDAD 10 TON o T O O LS EQUIPO PORT TIL DE PISTONES INFORMACI N DE ADVERTENCIA Este s mbolo indica una alerta de seguridad y se usa para ADVERTENCIA Indica una situaci n advertir sobre peligro de accidentes personales Observe toda ADVERTENCIA peligrosa que si no se evita puede la informaci n de seguridad que sigue a este simbolo para provocar la muerte o lesiones graves evitar la posibilidad de que ocurran lesiones o muerte IMPORTANTE LEA ESTAS INSTRUCCIONES ANTES DE USAR EL DISPOSITIVO ANTES DE USAR ESTE DISPOSITIVO LEA ESTE MANUAL DETENIDAMENTE PROCURE ENTENDER SUS PROCEDIMIENTOS OPERATIVOS ADVERTENCIAS DE SEGURIDAD Y FORMA DE MANTENIMIENTO El propietario es responsable de asegurarse de que todo el personal lea este manual antes de usar el dispositivo As
4. S U N E X MODEL 4910B CAPACITY 10 TON o T O O L S PORTABLE RAM KIT CONTENTS Page Specifications 1 2 Warning Information 3 Setup Operating Instructions 4 Preventative Maintenance Troubleshooting Owner User Responsibilities 5 Warranty Information 6 8 Exploded View Drawings and Replacement Parts i b UIN Ea SPECIFICATIONS Ram Capacity 10 Ton 7 250 psi Ram Minimum Height 322mm 12 68 Stroke 130mm 5 12 Fluid Capacity O Copyright 2011 Sunex Tools O 4910B 1 09 29 11 WARNING INFORMATION This is the safety alert symbol It is used to alert you WARNING Indicates a hazardous situation to potential personal injury hazards Obey all safety AWARNING which if not avoided could result in death messages that follow this symbol to avoid possible or serious injury injury or death A IMPORTANT READ THESE INSTRUCTIONS BEFORE OPERATING BEFORE USING THIS DEVICE READ THIS MANUAL COMPLETELY AND THOROUGHLY UNDERSTAND ITS OPERATING PROCEDURES SAFETY WARNINGS AND MAINTENANCE REQUIREMENTS It is the responsibility of the owner to make sure all personnel read this manual prior to using the device It is also the responsibility of the device owner to keep this manual intact and in a convenient location for all to see and read If the manual or product labels are lost or not legible contact Sunex for replacements If the operator is not fluent in English the product and safety instructions shall be read to and d
5. eventually it will become necessary to add hydrau lic fluid to the pump s reservoir Completely retract the ram before adding hydraulic fluid Do not overfill in order to avoid personal injury and hydraulic malfunction Use only hydraulic jack oil Chevron Hydraulic Oil AW ISO 32 or its equivalent Unocal Unax AW 150 Other fluids will cause damage to the hydraulic seals IMPORTANT In order to prevent seal damage and kit failure never use alcohol hydraulic brake fluid or transmission oil in the pump 3 Every kit owner is responsible for keeping the kit labels clean and readable Use a mild soap solution to wash external surfaces of the kit components but not any moving hydraulic components 4 Do not attempt to make any hydraulic repairs unless you are a qualified hydraulic repair person that is familiar with this equipment Repairs must be performed by an authorized service center TROUBLESHOOTING If repairs are necessary they must be performed in a dirt free environment by qualified personnel who are familiar with this equipment PROBLEM ACTION 1 Unit will not lift load Purge air from hydraulic system by following procedure under SETUP 2 Unit will not sustain load or feels spongy Purge air from hydraulic system as above under load 3 Unit will not lift to full height Purge air from hydraulic system as above 4 Unit still does not operate Contact Sunex authorized hydraulic service center OWNER USER RESPONSIBILITY
6. n cualquier parte o unidad la cual demuestra ser defectuosa en cuanto a material o mano de obra Otra importante informaci n de la garant a Esta garant a no cubre da os a equipo o herramientas debido a modificaciones abuso mal uso o da os y no cubre ninguna reparaci n o sustituci n hecha por ninguna persona que no sea Sunex Tools o alguno de sus centros de servicio de garant a autorizados La obligaci n antes mancionada queda bajo la responsabilidad exclusiva de Sunes Tools seg n se menciona o de cualquier garant a impl cita y bajo ninguna circunstancia quedar bajo su responsabilidad cualquier garant a impl cita ya bajo ninguna circunstancia quedar bajo su responsabilidad cualquier da o incidental o consecuencial NOTA Algunos estados no permiten la exclusi n ni limitaci n de da os Devuelva el equipo o partes a un centro de servicio autorizado con el flete prepagado Aseg rese de incluir su nombre y direcci n comprobaci n de la fecha de compra y la descripci n del defecto sospechado Si usted tiene alguna pregunta acerca del servicio de garant a escriba por favor a Sunex Tools Esta garant a le brinda derechos legales espec ficos y usted puede contar con derechos adicionales los cuales var an de estado a estado Est n disponibles equipos de reparaci n y partes de sustituci n para muchos de los productos de Sunex Tools independientemente del hecho de que el producto a n est cubierto o no por un plan de garant
7. P29 P30 P31 P32 P33 P34 P35 P36 P37 P38 P39 P40 P41 P42 P43 P44 P45 P46A P49 P52 Part Description Es Washer Seal E 0 Ring Washer Screw O Ring Washer Piston Pin Retaining Ring Pin Handle Socket RS10TP41 Handle Incl 42 Handle Sleeve Screw h Spring j Steel Ball RSPGAA Gauge Adapter Assembly RSPG Pressure Gauge Nylon Ring NOTE Items which are not identified by a part number or with an asterisk are not available separately 4910B A gt E dl dl dl ld E S M D nm a nm on ua 09 29 11 CAPACITY 10 TON S U N E xX MODEL 4910B T O O L S PORTABLE RAM KIT RS10TR RAM PARTS BREAKDOWN ltem Part Description Quantity RO1 RS10TRO1 Cover 1 R12 R02 Circlip 1 R03 Piston Rod 1 R04 s Circlip 1 R13 R05 Bushing 1 R06 x Nylon Ring 1 R07 7 Sealing Ring 1 R08 j Circlip 1 R09 Nut 1 R10 Spring 1 R11 Screw 1 R12 RS10TR12 Protection Cap 1 R13 Ring for Ram 1 R14 Cylinder 1 R14 R15 Screw 1 RSCPRA Coupler 1 Includes 10 S11 P11 S12 13 Items identified by an asterisk are available in Ram Seal Kit RS10TRSKA NOTE Items which are not identified by a part number or with an asterisk are not available separately RSSPR SPREADER PARTS BREAKDOWN Item Part Description Quantity S1 Pin 1 S2 Circlip 2 S3 Movable Jaw 1 S4 Spring 1 S5 Fixed Jaw 1 S6 Piston 1 S7 iS Cup Seal 1 S8 0 Ring 1 S9 End Cap 1 1 RSCPRA Coupler Includes 10 S11 P11 S12 13
8. d ploy ou sa course maximale Ouvrir la soupape de rel chement pour abaisser compl tement le v rin R p ter plusieurs fois ces tapes sans utiliser de charge d Si la situation s am liore sans toutefois tre pleinement satisfaisante r p ter les tapes b et c jusqu ce que l air soit compl tement purg du syst me DIRECTIVES Voici le symbole utilis dans la section DIRECTIVES D UTILISATION du pr sent guide pour avertir du risque de blessure corporelle Suivre toutes les directives pour viter des blessures potentiellement graves ou mortelles D terminer le travail effectuer de fa on choisir le type de v rin et les autres accessoires qui seront utilis s Consulter le tableau ci joint intitul Force applicable selon les montages de fa on d terminer la force maximale permise pour un montage sp cifique Chaque v rin est dot d un raccord femelle de d branchement de boyau et l extr mit du boyau se termine par un raccord m le d branchement rapide Ins rer fond le raccord m le d branchement rapide situ l extr mit du boyau dans le raccord femelle d branchement rapide du v rin Faire glisser le manchon filet du raccord de branchement femelle sur les filets du raccord de branchement m le et serrer la main Ne jamais utiliser d outils pour serrer ce raccordement Consulter la section du guide d utilisation intitul e FORCE APPLICABLE SELON LES MONTAGES
9. la trousse mais pas les composants hydrauliques mobiles Ne pas essayer de r parer des composants hydrauliques moins d tre un technicien qualifi en r paration de composants hydrau liques et d tre familier avec ce type d quipement Toute r paration doit tre effectu e par un centre de r paration autoris DIAGNOSTIC DE PANNES Si certaines r parations s av rent n cessaires elles doivent tre effectu es dans un environnement sans poussi re par un technicien qualifi qui est familier avec ce type d quipement PROBL ME SOLUTION 1 Le v rin ne soul ve pas la charge Purger l air du syst me hydraulique en suivant les directives de la section INSTALLATION 2 Le v rin ne supporte pas la charge ou Purger l air du syst me hydraulique en suivant les directives semble mou pendant que la charge est soulev e de la section INSTALLATION 3 Le v rin ne s l ve pas la hauteur maximale Purger l air du syst me hydraulique en suivant les directives de la section INSTALLATION 1 gt 4 Le v rin ne fonctionne toujours pas Veuillez communiquer avec le centre de service hydraulique autoris de Sunex 4910B 7 09 29 11 SUNEX MODEL 49108 CAPACIT DE 10 TON e T O O LS TROUSSE DE V RIN PORTABLE RESPONSABILIT DU PROPRI TAIRE UTILISATEUR Le propri taire et ou utilisateur doit poss der une compr hension des directives de fonctionnement et des mises en garde du manufacturier avant d
10. may have become trapped in the hydraulic system If the pump is not providing a full incremental pump stroke or the ram feels spongy it will be necessary to purge the air out of the hydraulic system a Before operating the pump turn the reservoir vent screw in a counterclockwise direction until it stops b Place the pump horizontally on a table Position the hose and ram over the edge of the table lower than the pump with the ram piston pointing down c Close the pump s release valve and pump the ram to its complete or its furthest extension Open the pump s release valve to retract the ram all the way Conduct this procedure several times without a load d If the condition seems better but is still detectable repeat steps b and c until all air is purged from the system OPERATING INSTRUCTIONS Y This is the Safety Alert Symbol used for the OPERATING INSTRUCTIONS section of this manual to alert you to potential personal injury hazards Obey all instructions to avoid possible injury or death 1 Study the work to be done in order to determine the type ram and other attachments you will be using Consult the enclosed Chart titled Applicable force for component set ups in order to determine the maximum allowable force to be used in your specific setup All rams have female hose disconnects attached to them and the end of the hose has the male quick disconnect attached to it Insert the male quick disconnect at the end of the
11. relaci n con sus INSTRUCCIONES DE USO ADVERTENCIAS DE SEGURIDAD y FORMA DE MANTENIMIENTO as como desatender las FORMAS DE EVITAR LAS SITUACIONES DE RIESGO puede provocar accidentes que tengan como consecuencia lesiones graves peligro de muerte o da os materiales 4910B 10 09 29 11 O S U N E X MODEL 4910B CAPACIDAD 10 TON o T O O L S EQUIPO PORT TIL DE PISTONES INSTRUCCIONES DE ENSAMBLAJE DEL EQUIPO DE POTENCIA HIDR ULICA PORT TIL tirle de los peligros potenciales de lesi n personal Obedezca todas las instrucciones para evitar lesiones potenciales o a n la muerte MONTAJE 1 Consulte el dibujo de partes de vista ampliada en este manual para identificar las partes mencionadas en este procedimiento de montaje 2 Instale el pist n en el extremo de la manguera y sujete juntas las conexiones de desconexi n r pida al apretar manualmente la manga roscada en la conexi n del pist n 3 Inserte el mango de bomba en el receptor de conexi n de la bomba y gire el mango en el sentido de las agujas del reloj hasta que est apretado Antes de operar la bomba gire el tornillo de ventila del dep sito en el contrasentido de las agujas del reloj hasta que ste se pare 4 Durante el env o o maniobra se puede atrapar aire en el sistema hidr ulico Si la bomba no est brindando un recorrido de bomba incremental completo o si el pist n se siente esponjado ser necesario purgar el aire del sistema hidr ulico Y ste es el
12. reservoir Completely retract the ram before adding hydraulic fluid Do not overfill in order to avoid personal injury and hydraulic malfunction Use only hydraulic jack oil Chevron Hydraulic Oil AW ISO 32 or its equivalent Unocal Unax AW 150 Other fluids will cause damage to the hydraulic seals 4910B 3 09 29 11 S U N E X MODEL 4910B CAPACITY 10 TON e T O O L S PORTABLE RAM KIT APPLICABLE FORCE bn FOR COMPONENT SET UPS T gt hae 4 W m i Spreader Capacity 50 of Ram Capacity of Ram Capacity gt IG Hi ho 100 of Ram Capacity 100 of Ram Capacity 25 of Ram Capacity HD gt ID l i E lt e 50 of Ram Capacity 6 of Ram Capacity PREVENTATIVE MAINTENANCE This is the safety alert symbol used for the PREVENTATIVE MAINTENANCE section of this manual to alert you to potential personal injury hazards Obey all instructions to avoid possible injury or death 1 Always store the kit in a well protected area where it will not be exposed to inclement weather corrosive vapors abrasive dust or any other harmful elements The kit must be cleaned of water snow sand or grit before using 2 Based on continuous engagement and disengagement of the hose from the cylinder
13. utiliser ce cric utilitaire Le personnel impliqu dans l utilisation de cette pi ce d quipement doit tre prudent comp tent bien entra n et qualifi au fonctionnement s curitaire et l utilisation ad quate de l quipement au moment de l entretien des v hicules et de leurs composantes On devrait insister particuli rement sur la compr hension des renseignements touchant les mises en garde Si l utilisateur ne parle pas couramment l anglais les directives du manufacturier et les mises en garde devraient tre lues et discut es par l acheteur propri taire avec l utilisateur dans sa langue maternelle pour s assurer de la bonne compr hension du contenu par l utilisateur Le propri taire et ou l utilisateur doit tudier et conserver les directives du manufacturier pour r f rence ventuelle Relativement aux tiquettes de mises en garde et aux manuels de directives le propri taire et ou l utilisateur est responsable de s assurer qu ils soient maintenus lisibles et intacts Les tiquettes de remplacement et la litt rature sont disponibles aupr s du manufacturier GARANTIE LIMIT E SUNEX INTERNATIONAL INC GARANTIT A SES CLIENTS QUE LES OUTILS DE MARQUE SUNEX TOOLS SONT EXEMPTS DE DEFAUTS DE MAIN D UVRE ET DE MATERIAU Sunex International Inc r parera ou remplacera ses outils de marque Sunex Tools qui ne donnent pas un service satisfaisant cause d un d faut de main d uvre ou de mat riau selon les te
14. 87 1 and OSHA standards Do not exceed the rated capacity Some kit attachments do not match the kit s rated capacity and the kit s rated capacity can also be reduced according to the number of kit attachments and extension tubes used and their assembly to the cylinder ram Please refer to the Owner s Manual section titled APPLYING FORCE for typical applications and corresponding load capacities USE THE FORCE GAUGE INCLUDED IN THIS KIT TO MONITOR CORRECT LOAD CAPACITIES Wedge Rams are rated at 1 ton capacity Rubber Heads are rated at 1 ton capacity in the 10 ton kit Do not overextend the rams When using extension tubes position the shortest tube farthest away from the cylinder Attachments and extension tubes must be aligned and fully engaged so the ram force is straight and avoids off center load conditions Before operating tighten all hose gauge and manifold connections so they are secure and leak free Do not over tighten or it may cause premature thread failure or split pressure fittings Tighten all hose quick disconnect fittings by hand only Do not subject the hose to extreme heat or cold sharp surfaces abrasion impact kinking twisting curling bending or any condition that restricts or affects fluid flow Make sure setup is stable and secure before performing any work Use this kit for the intended purpose of vehicle body frame repair only Only components supplied with this kit shall be used with this kit No alterations or modification
15. OMPLETAMENTE Y DE FORMA DETENIDA COMPRENDA SUS PROCEDIMIENTOS DE OPERACION ADVERTENCIAS DE SEGURIDAD Y REQUERIMIENTOS DE MANTENIMIENTO Es la responsabilidad del propietario del equipo asegurar que todo el personal lea este manual antes de usar el equipo Tambi n es la responsabilidad del propietario del equipo mantener intacto este manual y en un lugar conveniente para que todos lo vean y lean Si el manual o las etiquetas del producto se han perdido o no son legibles comun quese con Balkamp por unos repuestos Si el operador no domina el idioma ingl s el comprador propietario o su designado le debe leer las instrucciones de seguridad y del producto al operador en el idioma nativo del operador y discutirlas con l asegurando que el operador comprenda su contenido GARANTIA LIMITADA SUNEX INTERNATIONAL INC LE GARANTIZA A SUS CLIENTES QUE LAS HERRAMIENTAS Y PRODUCTOS CON LA MARCA DE LA EMPRESA SUNEX TOOLS NO CONTIENEN DEFECTOS EN SU MANO DE OBRA NI MATERIAS PRIMAS Sunex International Inc reparar o sustituir sus productos con la marca Sunex Tools que reflejen fallas en el funcionamiento satisfactorio debido a que la mano de obra o las materias primas est n defectuosas tomando como base las cl usulas y condiciones de los planes de garant a descritos a continuaci n y asignados a ese producto espec fico Esteproducto tiene una garant a de UN A O Durante este periodo de garant a Sunex Tools reparar o repondr a nuestra opci
16. RIN PORTABLE 11 Les raccords pneumatiques et hydrauliques d branchement rapide sont souvent d branch s et expos s la salet et aux d bris qui couvrent le sol des ateliers ou des surfaces de travail Il est important d utiliser les pare poussi re fournis pour emp cher les contami nants de p n trer dans les syst mes d alimentation en air et hydrauliques 12 tant donn que le boyau est fr quemment branch et d branch il deviendra ventuellement n cessaire d ajouter du liquide hy draulique dans le r servoir de la pompe Abaisser compl tement le v rin avant d ajouter du liquide hydraulique Ne pas d passer les niveaux recommand s afin d viter tout risque de blessure corporelle et de mauvais fonctionnement du syst me hydraulique Utiliser uniquement l huile hydraulique NAPA con ue pour les crics n 765 1541 ou n 765 1542 Tout autre liquide peut endommager les joints hydrauliques FORCE APPLICABLE SELON LES MONTAGES 25 de la capacit nomi gt TM iM 100 de la capacit Ha m Pa nominale du v rin 25 de la capacit nominale du v i HI jo i I 50 de la capacit nominale du v rin 6 de la capacit nominale du v rin z ENTRETIEN PREVENTIF Voi
17. S mbolo de Alerta de Seguridad usado para la secci n de INSTRUCCIONES DE ENSAMBLAJE de este manual para adver a Antes de operar la bomba gire el tornillo de ventila del dep sito en el contrasentido de las agujas del reloj hasta que ste se pare b Coloque la bomba horizontalmente en una mesa Coloque la manguera y el pist n sobre el borde de la mesa m s abajo que la bomba con el pist n apuntando hacia abajo c Cierre la v lvula de liberaci n de la bomba y bombee el pist n hasta lograr su completa extensi n o la m s extendida Abra la v l vula de liberaci n de la bomba para retractar el pist n completamente Repita este procedimiento varias veces sin la carga d Si la condici n aparenta estar mejorada pero aun sigue detectable repita los pasos b y c hasta que se haya purgado todo el aire del sistema INSTRUCCIONES DE OPERACI N ste es el S mbolo de Alerta de Seguridad usado para la secci n de INSTRUCCIONES DE OPERACI N de este manual para advertirle de los peligros potenciales de lesi n personal Obedezca todas las instrucciones para evitar lesiones potenciales o a n la muerte a Estudie el trabajo a realizarse con el fin de determinar el tipo de pist n y los dem s accesorios los que se emplear n Consulte la tabla adjunta titulada Potencia Aplicable para el Montaje de Accesorios con el fin de determinar la m xima potencia permisible a ser usada en su ensamblaje espec fico Todos los pistones cue
18. SSE DE V RIN PORTABLE DIRECTIVES D INSTALLATION DE LA TROUSSE DE V RIN HYDRAULIQUE PORTABLE Voici le symbole utilis dans la section DIRECTIVES D INSTALLATION du pr sent guide pour avertir du risque de blessure co porelle Suivre toutes les directives pour viter des blessures potentiellement graves ou mortelles INSTALLATION 1 Consulter la vue clat e du produit dans le guide afin d identifier les pi ces mentionn es dans la pr sente proc dure d installation 2 Installer le v rin l extr mit du boyau et brancher les raccords de boyau a d branchement rapide en serrant la main le manchon filet sur le raccord du v rin co Ins rer le manche dans le si ge pr vu cet effet et serrer fermement en tournant le manche dans le sens horaire Durant l exp dition ou la manutention des v rins il se peut que de l air ait t pi g dans le syst me hydraulique Si le v rin ne produit pas un mouvement de lev e complet et uniforme ou s il semble mou il sera n cessaire de purger l air du syst me hydraulique a Avant de faire fonctionner la pompe tourner la vis de purge d air du r servoir dans le sens antihoraire jusqu au bout b Placer la pompe horizontalement sur une table Mettre le boyau et le v rin sur le bord de la table plus bas que la pompe en faisant pointer le piston du v rin vers le bas c Fermer la soupape de rel chement de la pompe et pomper de sorte que le v rin soit compl tement
19. a DIRECCI N A EMBARCARSE DIRECCI N DE CORREOS Sunex Tools Sunex Tools 315 Hawkins Rd Travelers Rest P 0 Box 1233 Travelers Rest South Carolina 29690 South Carolina 29690 4910B 13 09 29 11 CAPACIT DE 10 TON L S TROUSSE DE V RIN PORTABLE S U N E xX MODEL 4910B TOO MANUAL DE OPERATI N CONTENU Page 14 Sp cifications 15 Information d avertissement 16 17 Installation op ration et entretien pr ventif 18 D pannage information de garantie et entretien e MECA EE SP CIFICATIONS Charge nominale 10 Tonnes 7 250 lb po Hauteur minimale du v rin 322mm 12 68 po Course 130mm 5 12 po Capacit en fluide 4910B 14 09 29 11 T O O LS TROUSSE DE V RIN PORTABLE AVERTISSEMENTS Ce symbole indique un danger potentiel Il est utilis AVERTISSEMENT Ce symbole pour avertir l utilisateur des risques potentiels de AVERTISSEMENT indique une situation dangereuse O S U N E X MODEL 4910B CAPACIT DE 10 TON gt blessures corporelles Pri re de respecter toutes les qui pourrait causer la mort ou des consignes de s curit qui suivent ce symbole afin blessures graves si elle n est pas d viter les blessures ou la mort potentielles vit e NATURE DES SITUATIONS POTENTIELLEMENT DANGEREUSES L utilisation des v rins hydrauliques portables entra ne certains risques qui ne peuvent tre vit s par des moyens m caniques mais par une utilisation intelligente prudente et empreinte de
20. afin de conna tre les installations habituelles des accessoires et des rallonges Pr ter tout particuli rement attention aux capacit s de charge de certains raccords d accessoires L utilisation de rallonges ou de pi ces d cartement pour piston r duit consid rablement la capacit du syst me hy draulique Lors de l utilisation de rallonges placer les tubes les plus courts aux extr mit s de l installation La pompe peut tre utilis e en position horizontale ou verticale mais elle doit pointer vers le bas lorsqu elle est utilis e en position verticale S assurer que tous les raccords hydrauliques et d accessoires sont bien install s et serr s de mani re ce que la force du v rin s exerce en ligne droite pour viter tout mauvais positionnement de la charge Lors de l acheminement du boyau pendant l installation s assurer de ne pas l emm ler le tordre l entortiller ou le plier ce qui entra verait la circulation du liquide hydraulique Ne pas se servir du boyau pour transporter l appareil Ne pas soumettre le boyau aux ris ques occasionn s par le feu la chaleur ou le froid extr me les surfaces coupantes ou les chocs intenses SI UN BOYAU SE ROMPT CLATE OU DOIT TRE D BRANCH ARR TER IMM DIATEMENT LA POMPE ET OUVRIR LA SOUPAPE DE REL CHEMENT POUR LIB RER LA PRESSION HYDRAULIQUE NE JAMAIS SAISIR UN BOYAU UN RACCORD OU UNE PI CE SOUS PRESSION QUI FUIT SINON DES BLESSURES GRAVES POURRAIENT EN R SULTER To
21. bon sens Leur utilisation n a de limite que l imagination et l ing niosit de l op rateur par cons quent Balkamp ne peut tre tenue responsable des dommages caus s au produit ou des blessures corporelles en raison d un jugement erron de l op rateur ou de l utilisation inad quate du produit Il est essentiel que les employ s qui utiliseront le produit soi ent vigilants comp tents form s et qualifi s pour ce qui est d utiliser de fa on s curitaire et appropri e le produit lorsqu ils r pareront le ch ssis ou les pi ces de carrosserie d un v hicule Exemples de situations dangereuses chute ou glissement de la charge en cas d arrimage inappropri de surcharge de mauvais positionnement de la charge et d installations inad quates D autres situations dan gereuses peuvent tre caus es par la rupture ou l clatement des boyaux hydrauliques et des raccords en raison d un usage abusif d un mauvais usage d une installation inad quate du produit ou d un usage pour lequel il n a pas t con u A AVERTISSEMENT DIRECTIVES POUR VITER LES SITUATIONS DANGEREUSES e S assurer de bien comprendre et de suivre toutes les directives avant d utiliser ce dispositif e Le propri taire de la trousse a la responsabilit de s assurer que la trousse est utilis e conform ment aux normes de s curit de OSHA de l tat ou de la province et de la r gion e Porter des lunettes de protection conformes
22. buidor 50 de capacidad del pist n 25 de capacidad del pist n gt ude MO D H Cri 100 me de capacidad del pist n 100 de capacidad del pist n 25 de capacidad del pist n gt oc Ch Coho CD 00 1 i1 50 de capacidad del pist n 6 de capacidad del pist n MANTENIMIENTO PREVENTIVO 44 ADVERTENCIA Este s mbolo de alerta de seguridad usado en la secci n de MANTENIMIENTO PREVENTIVO de este manual le advertir de los peligros potenciales de lesi n personal Obedezca todas las instrucciones para evitar lesiones potenciales o a n la muerte 1 Siempre almacene el equipo en un rea bien protegida donde sta no estar expuesta a las inclemencias del clima vapores corrosi vos polvo abrasivo ni a ning n otro elemento da ino Previo al uso el equipo debe ser limpio de agua nieve arena y arenilla Tomando en cuenta el encaje y desencaje continuo de la manguera del cilindro eventualmente ser necesario agregar l quido hidr u lico al dep sito de la bomba Retracte el pist n completamente antes de a adir l quido hidr ulico No lo sobrellene para as evitar lesio nes personales y el mal funcionamiento hidr ulico Use s lo l quido hidr ulico para gato Chevron AW ISO 32 o Unocal Unax AW 150 Otros l quidos ocasionar n da os a los sellos hidr ulicos N IMPORTANTE Con elfin de prevenir da os de sello o fallas del equipo nunca use alcohol l qu
23. ci le symbole utilis pour dans la section ENTRETIEN PR VENTIF du pr sent guide pour avertir du risque de blessure corporelle Suivre toutes les directives pour viter des blessures potentiellement graves ou mortelles Toujours entreposer le produit dans un endroit o il sera prot g des intemp ries des vapeurs corrosives de la poussi re abrasive et des autres l ments nocifs Le produit doit tre exempt d eau de neige de sable et de particules avant l utilisation tant donn que le boyau est fr quemment branch et d branch il deviendra ventuellement n cessaire d ajouter du liquide hy draulique dans le r servoir de la pompe Abaisser compl tement le v rin avant d ajouter du liquide hydraulique Ne pas d passer les niveaux recommand s afin d viter tout risque de blessure corporelle et de mauvais fonctionnement du syst me hydraulique Utiliser uniquement l huile hydraulique NAPA congue pour les crics n 765 1541 ou n 765 1542 Tout autre liquide peut endommager les joints hydrauliques IMPORTANT Pour pr venir les dommages aux joints d tanch it et la d fectuosit du produit ne jamais utiliser d alcool de liquide a freins hydrauliques ni d huile a transmission dans la pompe D co Le propri taire de la trousse doit s assurer que les tiquettes appos es sur le produit demeurent propres et lisibles Utiliser une solu tion savonneuse douce pour nettoyer les surfaces externes des pi ces de
24. des filets ou un fendillement des raccords pression Serrer tous les raccords de boyau d branchement rapide la main seulement e Ne pas soumettre le boyau la chaleur ou au froid extr me le faire entrer en contact avec des surfaces coupantes ou abrasives Ne pas le cogner l emm ler le tordre l entortiller le plier ou l astreindre des conditions qui restreignent ou affectent la circulation du liquide S assurer que l installation est stable et s curitaire avant d effectuer des travaux Utiliser cette trousse pour l usage auquel elle est destin e soit la r paration du ch ssis ou de la carrosserie d un v hicule seulement Seules les pi ces fournies dans cette trousse devraient tre utilis es avec le v rin Les pi ces de la trousse ne devraient subir aucune alt ration ni aucune modification Le non respect de ces mises en garde peut provoquer des blessures corporelles ou des dommages mat riels ou les deux A AVERTISSEMENT CONS QUENCES SI LES SITUATIONS DANGEREUSES NE SONT PAS VIT ES Le d faut de lire le guide d utilisation au complet de s assurer de comprendre et de suivre LES PROC DURES D UTILISATION LES AVERTISSEMENTS ET LES EXIGENCES D ENTRETIEN et de respecter les DIRECTIVES POUR EVITER LES SITUATIONS DANGEREUSES pourrait causer des accidents et provoquer des dommages mat riels ou des blessures graves ou mortelles 4910B 15 09 29 11 SUNEX MODEL 49108 CAPACIT DE 10 TON o T O O L S TROU
25. ervice de garantie Sunex Tools Cette garantie donne l acheteur des droits juridiques sp cifiques ainsi que certains autres droits qui peuvent varier selon la juridiction Apr s ch ance de la garantie de remplacement direct d un an certaines pi ces de service seront disponibles l achat par l entremise des options de services normaux de Sunex Tools ADRESSE D EXP DITION ADRESSE POSTALE Sunex Tools Sunex Tools 315 Hawkins Rd P 0 Box 1233 Travelers Rest South Carolina 29690 Travelers Rest South Carolina 29690 4910B 18 09 29 11
26. hose all the way in to the ram s female quick disconnect Slide the female connector s threaded sleeve on to the threads of the male connector and hand tighten Never use any tools to tighten this connection 2 Consult this Owner s Manual section titled APPLICABLE FORCE FOR COMPONENT SET UPS for typical attachment and extension tube setups and pay very close attention to the corresponding load ratings of certain attachment connections The use of extension tubes ram or plunger toes greatly reduces the hydraulic system s capacity When using extension tubes put the shortest tubes on the ends of the setup 3 The pump may be operated in the horizontal or vertical position but the pump must point down when used in the vertical position 4 Make sure all hydraulic and attachment connections are fully engaged and tight so ram force is straight in order to avoid off center load conditions 5 During setup make sure the hose routing avoids kinks twists curls or bends that will impede hydraulic fluid flow Do not use the hose as a means to carry the kit components Do not subject the hose to any hazards such as fire extreme heat or cold sharp surfaces or heavy impact IF A HOSE RUPTURES BURSTS OR NEEDS TO BE DISCONNECTED IMMEDIATELY SHUT THE PUMP OFF AND OPEN THE RELEASE VALVE TO RELEASE HYDRAULIC PRESSURE NEVER GRASP A LEAKING PRESSURIZED HOSE FITTING OR COMPONENT WITH YOUR HANDS OR SUFFER SERIOUS INJURY 6 Always use the force gauge to make sure y
27. ido hidr ulico de freno ni aceite para transmisiones en la bomba go Cada propietario del equipo ser responsable por mantener limpias y legibles las etiquetas del equipo Use una soluci n de jab n suave para limpiar las superficies externas de los componentes del quipo pero no limpie los componentes hidr ulicos m viles No intente realizar ninguna reparaci n hidr ulica al menos que usted sea un individuo calificado en las reparaciones hidr ulicas famil iarizado con este equipo Las reparaciones deben realizarse por parte de un centro de servicio autorizado DIAGN STICO DE AVER AS Si se requieren unas reparaciones stas deben realizarse en un ambiente libre de suciedad por parte de personal calificado familiarizado con este equipo gt PROBLEMA ACCI N 1 No se levantar la carga Purgue el aire del sistema hidr ulico al seguir el procedimiento a continuaci n bajo MONTAJE 2 La unidad no sostendr la carga o se siente esponjado Purgue el aire del sistema hidr ulico seg n lo anterior bajo la carga 3 La unidad no levantar hasta su altura completa Purgue el aire del sistema hidr ulico seg n lo anterior 4 La unidad a n no funciona Comun quese con un centro de servicio hidr ulico autorizado de Sunex 4910B 12 09 29 11 O S U N E X MODEL 4910B CAPACIDAD 10 TON o T O O LS EQUIPO PORT TIL DE PISTONES RESPONSABILIDAD DEL PROPIETARIO USUARIO ANTES DE USAR ESTE EQUIPO LEA EL MANUAL C
28. imismo es responsabilidad del propietario mantener este manual en buenas condiciones en una ubicaci n conveniente para su consulta Si las etiquetas del manual o producto son ilegibles o no est n en su lugar deber ponerse en contacto con Sunex para obtenerlas gratis El comprador propietario o una persona designada deber leer y comentar el producto y las advertencias de seguridad en la lengua materna del operario que no hable ingl s fluido a fin de asegurarse de que comprende el contenido NATURALEZA DE LAS SITUACIONES DE RIESGO 44 ADVERTENCIA El uso de dispositivos de elevaci n de automotores se halla sujeto a ciertos riesgos que no se pueden prever por medios mec nicos sino por la informaci n la diligencia y el sentido com n Por lo tanto es esencial que el uso del dispositivo quede en manos de los propietarios y de personal que sea cuidadoso competente capacitado y habilitado para realizar una operaci n segura Algunos ejemplos de peligros son dejar caer inclinar o resbalar las cargas principalmente como consecuencia de una sujeci n incorrecta sobrecarga posici n no centrada uso en superficies no niveladas o firmes as como usar el dispositivo con un fin para el que no est dise ado FORMAS DE EVITAR LAS SITUACIONES DE RIESGO 44 ADVERTENCIA Lea estudie comprenda y observe todas las instrucciones antes de operar este dispositivo Verifique el gato antes de usarlo No lo use si tiene roturas alteraciones fuga
29. is cussed with the operator in the operator s native language by the purchaser owner or his designee making sure that the operator compre hends its contents THE NATURE OF HAZARDOUS SITUATIONS AAWARNING The use of Portable Hydraulic Power Kits is subject to certain hazards that cannot be prevented by mechanical means but only by the exer cise of intelligence care and common sense The versatility of use is limited only by the imagination and ingenuity of its operator therefore Sunex cannot be responsible for product damage or personal injury due to faulty operator judgement or improper use of the kit It is es sential to have personnel involved in the use and operation of the kit who are careful competent trained and qualified in the safe operation of the kit and its proper use when working on vehicle frames and body parts Examples of hazards are dropping or slipping of load caused by improperly securing loads overloading off centered loads and improper setups Additional hazards may be caused by the rupture or bursting of the hydraulic hoses and related fittings due to abuse misuse improper setup and using the kit for a purpose for which it was not intended METHODS TO AVOID HAZARDOUS SITUATIONS AAWARNING Study understand and follow all instructions before operating this device The kit owner is responsible for the kit being used in accordance with OSHA state and local safety standards Wear eye protection that meets ANSI Z
30. la norme ANSI 787 1 et aux normes de OSHA e Ne pas d passer la capacit nominale La capacit nominale de certains accessoires de la trousse ne correspond pas celle de la trousse et la capacit nominale de la trousse peut aussi tre r duite selon le nombre d accessoires et de rallonges utilis s et de leur montage sur le v rin Veuillez vous r f rer la section du guide d utilisation intitul e FORCE APPLICABLE pour conna tre les applica tions habituelles et les capacit s de charge correspondantes UTILISER LE DYNAMOMETRE INCLUS DANS CETTE TROUSSE POUR V RIFIER SI LES CAPACIT S DE CHARGE SONT AD QUATES Les v rins carteurs ont une capacit nominale de 1 tonne Les t tes en caoutchouc ont une capacit nominale de Y tonne dans la trousse du v rin de 4 tonnes et une capacit nominale de 1 tonne dans la trousse du v rin de 10 tonnes Ne pas d ployer de fa on excessive les v rins Lors de l utilisation de rallonges placer le tube le plus court le plus loin possible du cylindre e Les accessoires et les rallonges doivent tre align s et correctement ins r s de mani re ce que la force du v rin s exerce en ligne droite pour viter tout mauvais positionnement de la charge e Avant l utilisation bien serrer tous les branchements boyau manom tre et distributeur de fa on ce qu ils ne se d fassent pas et ne pr sentent aucune fuite Ne pas trop les serrer car cela pourrait causer un bris pr matur
31. lamente Si el montaje requiere una clasificaci n reducida el operador ser responsable por usar el calibrador con el fin de determinar cuando se debe de dejar de bombear dado que la v lvula de sobrecarga est ajustada a una clasificaci n nominal mayor 10 Aseg rese que el pist n est completamente retractado adentro de su cilindro antes de desconectar la manguera del cilindro 11 Los acoplamientos hidr ulicos y neum ticos de desconexi n r pida son repetidamente desconectados y expuestos a los pisos de taller o del lugar del trabajo los que est n cubiertos con suciedad y escombros Es importante usar sobrecubiertas anti polvo para prevenir que los contaminantes no entren a los sistemas neum ticos e hidr ulicos 12 Tomando en cuenta el encaje y desencaje continuo de la manguera del cilindro eventualmente ser necesario agregar l quido hidr u lico al dep sito de la bomba Retracte el pist n completamente antes de a adir l quido hidr ulico No lo sobrellene para as evitar lesiones personales y el mal funcionamiento hidr ulico Use s lo l quido hidr ulico para gato NAPA 765 1541 o 765 1542 Otros l quidos ocasionar n da os a los sellos hidr ulicos 4910B 11 09 29 11 D En Le SD NO O S U N E X MODEL 4910B CAPACIDAD 10 TON o T O O L S EQUIPO PORT TIL DE PISTONES POTENCIA APLICABLE PARA gt h n p LOS COMPONENTES DE MONTAJE 50 de capacidad del pist n Ea ER merde Capacidad del distri
32. ntan con desconexiones hembras de manguera sujetadas a ellos y el fin de la manguera tiene una desconexi n r pida macho sujetada a ella Inserte completamente la desconexi n r pida macho al final de la manguera en la desconexi n r pida hembra del pist n Deslice la manga enroscada del conector hembra en las roscas del conector macho y apri tela manualmente Nunca use ninguna herramienta para apretar esta conexi n Consulte la secci n de este Manual del Propietario titulada POTENCIA APLICABLE PARA EL ENSAMBLAJE DE LOS COMPONEN TES para el ensamblaje de accesorios y tubos de extensi n t picos y preste mucha atenci n a las clasificaciones de carga correspon dientes de ciertas conexiones de accesorio El uso de tubos de extensi n pistones o dedos de mbolo reduce de manera dr stica la capacidad del sistema hidr ulico Al momento de usar UNOS tubos de extensi n coloque los tubos cortos en los extremos del ensamblaje La bomba puede operarse en una posici n horizontal o vertical sin embargo la bomba debe estar apuntada hacia abajo cuando sta se use en la posici n vertical Aseg rese que todas las conexiones hidr ulicas y de los accesorios est n completamente encajadas y apretadas para que la poten cia del pist n est recta con el fin de evitar condiciones de cargas no centradas Durante el montaje aseg rese que la ruta de la manguera evite curvas retorcimientos espirales y dobladuras los que impiden el flujo del l
33. ou are within the required force range when operating the system 7 In order to pump the ram it will be necessary to turn the release valve knob in a clockwise direction until tight Tighten by hand only 8 Pumping the handle up and down transfers the hydraulic fluid from the pump s reservoir through the hose in to the cylinder and extends the ram with each incremental pump stroke 9 To release the pressure and return the ram back in to its cylinder turn the release valve knob in a counterclockwise direction very slowly Turning the release valve knob slowly will determine the speed in which the ram will retract back into its cylinder IMPORTANT The pump includes an overload valve that will activate at the pump s rated capacity only If the setup requires a re duced rating the operator is responsible for using the gauge to determine when to stop pumping since the overload valve is set to a higher rating 10 Make sure the ram is completely retracted inside its cylinder before disconnecting the hose from the cylinder 11 The air and hydraulic quick disconnect fittings are repeatedly disconnected and exposed to shop or work place floors that are cov ered with dirt and debris It is important to use the dust caps provided to prevent contaminants from entering the air and hydraulic systems 12 Based on continuous engagement and disengagement of the hose from the cylinder eventually it will become necessary to add hydraulic fluid to the pump s
34. quido hidr ulico No use la manguera como medida para llevar los componentes del equipo No sujete la manguera a ning n peligro tal como incendio calor o fr o extremo superficies agudas ni impactos fuertes SI SE ROMPE O SE REVIENTA UNA MANGUERA O SI ESTA REQUIERSE SER DESCONECTADA APAGUE LA BOMBA INMEDIATAMENTE Y ABRA LA VALVULA DE LIB ERACION PARA LIBERAR LA PRESION HIDRAULICA NUNCA AGARRE UNA MANGUERA PRESURIZADA CONEXI N O COMPO NENTE CON FUGAS CON LAS MANOS O SE SUFRIR N LESIONES SERIAS Siempre use el indicador de potencia para asegurar que se encuentre dentro del rango de potencia requerido al momento de operar el sistema Para poder bombear el pist n ser necesario girar la perilla de la v lvula de liberaci n en el sentido de las agujas del reloj hasta que est apretada Apri tela manualmente solamente Cuando se bombea el mango hacia arriba y hacia abajo se transfiere l quido hidr ulico del recipiente de la bomba a trav s de la manguera en el cilindro y se extiende el pist n con cada recorrido incremental de la bomba Para liberar la presi n y volver el pist n al cilindro gire la perilla de la v lvula de liberaci n lentamente en el contrasentido de las agu jas del reloj Al girar la perilla de la v lvula de liberaci n lentamente se podr determinar la velocidad en la que el pist n se retracta en su cilindro IMPORTANTE La bomba incluye una v lvula a rea que activar la capacidad nominal de la bomba so
35. rmes et conditions d crits ci dessous dans les plans de garantie correspondant ce produit sp cifique Ce produit a une garantie de UN AN Pendant la p riode de garantie Sunex Tools r parera ou remplacera sa seule discr tion toute pi ce ou tout appareil dont il a t d termin qu il comporte un d faut de mat riau ou de main d uvre Autres informations importantes sur la garantie Cette garantie ne couvre pas les dommages de l quipement ou des outils modifi s sujets des abus ou une utilisation incorrecte ou encore endommag s elle ne couvre pas les r parations ou le remplacement effectu par quiconque autre que Sunex Tools ou ses centres de services de garantie autoris s L obligation qui pr c de constitue la seule responsabilit de Sunex Tools en vertu de cette garantie ou de toute garantie implicite et en aucun cas Sunex Tools ne pourra tre responsable pour des dommages indirects ou cons cutifs Remarque Certaines juridictions ne permettent pas l exclusion ou la limitation des dommages indirects ou cons cutifs la limitation ou l exclusion ci dessus pourrait donc ne pas s appliquer votre cas Retourner l quipement ou les pi ces Sunex Tools ou un centre de service de garantie autoris port pr pay S assurer d inclure votre nom votre adresse une preuve de la date d achat et la description de la d faillance pr sum e Veuillez adresser par crit toutes vos questions sur le s
36. s de l quido hidr ulico o est en malas condiciones como tampoco si presenta inestabilidad debido a piezas met licas o partes desajustadas o faltantes Tome las medidas de correcci n apropiadas antes de usarlo Utilice el dispositivo de elevaci n nicamente en las reas del veh culo especificadas por su fabricante Use protecci n para los ojos que cumpla con las normas ANSI Z87 1 y OSHA No use el gato para elevar pesos superiores a su capacidad Este dispositivo se debe utilizar nicamente para levantar cargas No bien haya elevado la carga sujete el veh culo con torres que tengan la capacidad para sostenerlo antes de comenzar a trabajar Use el gato nicamente en superficies niveladas firmes en las que no haya obst culos de modo que el dispositivo pueda posicionarse durante las operaciones de elevaci n y descenso Centre la carga en el asiento Aseg rese de que el armado del dispositivo sea estable antes de comenzar a trabajar No mueva ni empuje el veh culo sobre el gato No utilice ning n tipo de adaptador ni extensi n entre el asiento del gato y la carga No use adaptadores a menos que Sunex los haya aprobado o suministrado Baje el gato siempre despacio y con cuidado No cumplir con estas indicaciones puede provocar lesiones graves o peligro de muerte as como da os materiales CONSECUENCIAS DE NO PREVENIR LAS SITUACIONES DE RIESGO 44 ADVERTENCIA No leer comprender u observar todo el contenido de este manual en
37. s shall be made to any of the kit components Failure to heed these warnings may result in personal injury property damage or both CONSEQUENCES OF NOT AVOIDING HAZARDOUS SITUATIONS A WARNING Failure to read this manual completely and thoroughly failure to understand its OPERATING INSTRUCTIONS SAFETY WARNINGS MAINTENANCE INSTRUCTIONS and comply with them and failure to comply with the METHODS TO AVOID HAZARDOUS SITUATIONS could cause accidents resulting in serious or fatal personal injury and or property damage 4910B 2 09 29 11 O S U N E X MODEL 4910B CAPACITY 10 TON o T O O L S PORTABLE RAM KIT PORTABLE HYDRAULIC POWER KIT SETUP INSTRUCTIONS SETUP This is the Safety Alert Symbol used for the SETUP INSTRUCTIONS section of this manual to alert you to potential personal injury hazards Obey all instructions to avoid possible injury or death PLEASE REFER TO THE EXPLODED VIEW DRAWING IN THIS MANUAL IN ORDER TO IDENTIFY PARTS 1 Refer to the exploded view parts drawing in this manual to identify parts mentioned in this setup procedure 2 Install the ram at the end of the hose and secure the quick disconnect fittings together by hand tightening the threaded sleeve on the ram fitting 3 Insert the pump handle in the pump linkage receiver and rotate the handle clockwise until tight Before operating the pump turn the reservoir vent screw in a counterclockwise direction until it stops 4 During shipping or handling air
38. ship Other important warranty information This warranty does not cover damage to equipment or tools arising from alteration abuse misuse damage and does not cover any repairs or replacement made by anyone other than Sunex Tools or its authorized warranty service centers The foregoing obligation is Sunex Tools sole liability under this or any implied warranty and under no circumstances shall we be liable for any incidental or consequential damages NOTE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Return equipment or parts to an authorized service center transportation prepaid Be certain to include your name and address evidence of the purchase date and description of the suspected defect If you have any questions about warranty service please write to Sunex Tools This warranty gives you specific legal rights and you may also have other rights which vary from state to state Repair kits and replacement parts are available for many of Sunex Tools products regardless of whether or not the product is still covered by a warranty plan SHIPPING ADDRESS MAILING ADDRESS Sunex Tools Sunex Tools 315 Hawkins Rd P 0 Box 1233 Travelers Rest South Carolina 29690 Travelers Rest South Carolina 29690 4910B 5 09 29 11 CAPACITY 10 TON L S PORTABLE RAM KIT S U N E xX MODEL 49108 T O O 4910B 10 TON RAM KIT PARTS LIST AND DRAWING
39. ujours utiliser le dynamom tre pour s assurer que la plage de force requise est respect e lors de l utilisation du syst me Pour d ployer le v rin il sera n cessaire de tourner le bouton de la soupape de rel chement dans le sens horaire jusqu ce qu il soit bien serr Serrer la main seulement Le fait de lever et d abaisser le manche fait circuler le liquide hydraulique dans le boyau du r servoir de la pompe jusqu au cylindre et allonge le v rin chaque mouvement de lev e uniforme Pour lib rer la pression et abaisser le v rin dans le cylindre tourner tr s lentement le bouton de la soupape de rel chement dans le sens antihoraire Le fait de tourner lentement le bouton de la soupape de rel chement fera en sorte d abaisser le v rin dans le cylindre tout aussi lentement IMPORTANT La pompe est munie d une soupape de surpression qui se d clenche uniquement lorsque la capacit nominale de la pompe est atteinte Si l installation n cessite une capacit nominale r duite l op rateur doit utiliser le manom tre pour d terminer le moment o le pompage doit tre arr t tant donn que la soupape de surpression est r gl e pour une capacit nominale sup rieure 10 S assurer que le v rin est compl tement r tract dans le cylindre avant de d brancher le boyau du cylindre D go gt gi 9 po o 4910B 16 09 29 11 SUNEX MODEL 49108 CAPACIT DE 10 TON o T O O L S TROUSSE DE V
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung - Weber Grill Shop - BBQ-Grill-Shop Whirlpool EL7JWKLMQ00 User's Manual AJ65SBT-CLB CC-Link-CC-Link/LT Bridge Module User`s Manual LC-XG400D 型 LC-XG400DL※型 取扱説明書 KWC K.26.99.10.000 User's Manual Samsung SPH-A820B manual do usuário MANUEL D`INSTRUCTIONS Instructions for use Mode d`emploi 取扱説明書 C92SKS1A MANUAL DEL PROPIETARIO Honda VTX1300S Copyright © All rights reserved.
Failed to retrieve file