Home
U - Cydesa
Contents
1. Reguladores inteligentes smart controllers Los reguladores de energ a reactiva Masing FPM permiten maniobrar hasta 6 o 12 escalones seg n modelo Partiendo de una conexi n monof sica de corriente y tensi n mide Tension Corriente Potencia Activa Reactiva y Aparente Distorsi n arm nica THD ademas de la temperatura en el interior del armario memoriza los valores m ximos de las medidas para facilitar el an lisis de las causas de posibles aver as Permite seleccionar escalones fijos y fijo en stanby para compensar la potencia reactiva del transformador de potencia de la red evitando as la instalaci n independiente de un condensador Registra las horas de funcionamiento para facilitar las labores preventivas de mantenimiento Para una compensaci n precisa y un control exhaustivo de la red los reguladores trif sicos Masing FPMp Premium constituyen la soluci n m s inteligente del mercado para la regulaci n del factor de potencia Adem s incorpora las funciones de un completo analizador de redes Reactive power regulators Masing FPM allow monitoring up to 6 or 12 steps according to model Starting from a single phase connection of current and voltage mesure voltage current active power reactive and apparent power harmonic distortion THD besides the temperature inside the cabinet memorizes the maximum values of the measures to facilitate the analysis of the causes of possible failure Allow to select fixe
2. Denominacion y caracteristicas diferenciales Differential characteristics Aplicacion Application Pagina Page In sheet steel cabinet 100 700 25 800 20 7 1000 100 700 100 700 1 Tensi n a la que se refiere la potencia de la bater a 2 Para instalar en la acometida general de la instalaci n 400 400 400 400 400 ESTANDAR CON CONTACTORES EST TICOS STANDARD WITH STATIC CONTACTORS e Regulador FPM max 6 o 12 escalones FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector e Contactores est ticos Static contactors ESTANDAR CON FILTROS STANDARD WITH FILTERS e Regulador FPM max 6 o 12 escalones FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector e Reactancias por escal n para filtros de rechazo de arm nicos 189Hz Reactors for harmonic filters PREMIUM PREMIUM e Regulador FPM m x 6 o 12 escalones FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector e Contactores y condensadores sobredimen sionados Over rated contactors and capacitors PREMIUM CON CONTACTORES EST TICOS PREMIUM WITH STATIC CONTACTORS e Regulador FPM m x 6 o 12 escalones FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector e Contactores sobredimensionados Over rated contactors e Contactores
3. Serie hasta 24 kV Series up to 24 kV Potencia Potencia reactiva nominal Sn a potencia nominal Rated Reactive output at power Sn a rated power kVA kvar 2b 50 100 160 250 400 500 630 800 1000 1250 1600 2000 2500 104 CYDESA Expertos en energ a reactiva y arm nicos Potencia de conden sadores recomen dada al 30 de la potencia nominal Recommended capacitors output at a rate of 80 of the transformer rated power kvar Serie hasta 36 kV Series up to 36 kV Potencia reactiva a potencia nominal Reactive output at rated power kvar Potencia de conden sadores recomendada al 80 de la potencia nominal Recommended capa citors output at a rate of 80 of the trans former rated power kvar 2 3 5 10 12 5 20 25 30 45 50 70 80 100 120 Technical handbook Tables and formularies Tabla Il Table II Compensaci n de motores Potencia Motors compensation de motores as ncronos normalizados Power standard asynchronous junto a la potencia de condensadores motors with the power capacitor recomendada recommended Potencia del Condensador Capacitor output Potencia del Condensador Capacitor output Potencia del Condensador Capacitor output Potencia del Condensador Capacitor output 8000rpm 1500rpm 1000r p m 750 r p m 75 10 2 5 5 0 5 0 75 15 20 5 0 5 0 7b 10 0 22 30 7 5 7 5 10 0 15 0 37 50 10 0 12 5 15 0
4. Technical data e Technical data on page 44 e With series FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Autotrans for aux voltage 400 230V e Incoming at the bottom e Optional residual current protection e Floor mounted Potencia Composici n Output Composition kvar 400V kvar 440V 400 8x50 484 400 2x25 7x50 484 425 25 8x50 514 425 25 8x50 514 450 9x50 545 450 9x50 545 450 2x25 8x50 545 450 2x25 8x50 545 475 25 9x50 575 500 10x50 605 500 2x25 9x50 605 525 25 10x50 635 550 11x50 666 575 25 11x50 696 600 12x50 726 625 25 2x50 5x100 756 650 50 6x100 787 675 25 50 6x100 817 700 2x50 6x100 847 725 25 2x50 6x100 877 750 50 7x100 908 775 25 1x50 7x100 938 800 2x50 7x100 968 850 50 8x100 1029 900 2x50 8x100 1089 950 50 9x100 1150 1000 2x50 9x100 1210 400V 50Hz Dimensiones Peso Tipo Dimensions Weight Type HxAxB mm kg 2000x600x600 224 EG 400 400 8 8 2000x600x600 224 EG 400 400 9 16 2000x600x600 235 EG 400 425 9 17 2000x1200x600 313 EG 400 425 9 17 A 2000x 600x600 237 EG 400 450 9 9 2000x1200x600 316 EG 400 450 9 9 A 2000x600x600 238 EG 400 450 10 18 2000x1200x600 316 EG 400 450 10 18 A 2000x1200x600 320 EG 400 475 10 19 2000x1200x600 323 EG 400 500 10 10 2000x1200x600 323 EG 400 500 11 20 2000x1200x600 336 EG 400 525 11 21 2000x1200x600 340 EG 400 550 11 11 2000x1200
5. 12 5 2x25 3x50 257 1890x580x445 143 EL 400 212 5 6 17 5 278 00 630 840 00 225 25 4x50 272 1890x580x445 148 EL 400 225 5 9 5 335 00 630 840 00 237 5 12 5 25 4x50 287 1890x580x445 150 EL 400 237 5 6 19 5 503 00 630 840 00 250 2x25 4x50 303 1890x580x445 151 EL 400 250 6 10 5 615 00 630 840 00 275 25 5x50 333 1890x580x445 153 EL 400 275 6 11 5 897 00 630 840 00 300 6x50 363 1890x580x445 155 EL 400 300 6 6 6 176 00 630 840 00 300 2x25 5x50 363 1890x580x445 156 EL 400 300 7 12 6 289 00 630 840 00 325 25 6x50 393 1890x580x445 160 EL 400 325 7 13 6 738 00 800 1 221 00 350 2x25 6x50 424 1890x580x445 163 EL 400 350 8 14 6 913 00 800 1522500 375 25 7x50 454 1890x580x445 161 EL 400 375 8 15 7 299 00 800 1 221 00 400 2x25 7x50 484 1890x580x445 168 EL 400 400 9 16 7 860 00 1000 1 627 00 425 25 8x50 514 1890x1160x445 256 EL 400 425 9 17 9 686 00 1000 2 402 00 450 9x50 545 1890x1160x445 258 EL 400 450 9 9 9 938 00 1000 2 402 00 450 2x25 8x50 545 1890x1160x445 258 EL 400 450 10 18 10 051 00 1000 2 402 00 475 2549x50 575 1890x1160x445 261 EL 400 475 10 19 10 331 00 1000 2 402 00 500 10x50 605 1890x1160x445 263 EL 400 500 10 10 10 555 00 1250 2 608 00 500 2x25 9x50 605 1890x1160x445 264 EL 400 500 11 20 10 668 00 1250 2 608 00 525 25 10x50 635 1890x1160x445 256 EL 400 525 11 21 11 005 00 1250 2 608 00 550 11x50 666 1890x1160x445 268 EL 400 550 11 11 11 229 00 1250 2 608 00 575 25 11x50 696 1890x1160x445 271 EL 400 575 12 23 11 790
6. 5 C to 35 C average in 24h maximum 40 C Tipo Precio Type Price PROSEC 230 7 5 1 315 00 PROSEC 230 12 5 1 462 00 PROSEC 230 15 1 489 00 PROSEC 230 20 1 843 00 PROSEC 230 25 1 923 00 PROSEC 230 30 2 039 00 PROSEC 230 35 2 598 00 PROSEC 230 37 5 2 713 00 PROSEC 230 40 2 714 00 PROSEC 230 45 2 953 00 PROSEC 230 50 2 992 00 Capacitor Bank Prosec 230 V bOHz from 60 to 80 kvar Technical Data e Floor mounted e With Series controller Masing FPM e Capacitors ESTAprop 2 steps e Contactors with resistors prior to current limiting connection Only e Switch disconnector e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 e Incoming at the bottom 230V Potencia Composici n Dimensiones Calibre Output Composition Dimensions int HxAxB kvar mm A 60 2x10 2x20 1170x785x460 250 70 10 3x20 1170x785x460 250 80 4x20 1170x785x460 400 e Acceptable ambient temperature 5 C to 35 C average in 24h maximum 40 C Tipo Precio Type Price PROSEC 230 60 5 241 00 PROSEC 230 70 5 588 00 PROSEC 230 80 5 950 00 CYDESA Experts in reactive energy and harmonics 43 Lista de Precios 2014_Equipos Bater as de condensadores estandar Standard capacitor banks e Normas CEl 61921 2003 EN 61921 Bater as de condensado res de compensaci n del factor de potencia de baja tensi n e Protecci n el ctrica fusible y dispositivo de seguridad en los condensadores por desconexi n e
7. AF there is none of the above problems of passive active filters The figure shows how to operate a filter active network injecting harmonic currents selected in antiphase to the existing or distorting loads generated Technical handbook Active Filters Elecci n del filtro activo Los filtros Ecosine Active se suministran en ejecuciones de e 3 hilos para redes trifasicas sin neutro o sin cargas monofasicas por tanto son adecuados para instalaciones donde predominan las cargas trifasicas con un numero muy reducido de cargas monofasicas e 4 hilos para redes trifasicas con predominio de cargas monofasicas cargas t picas en edificios de oficinas El neutro admite una corriente de hasta 3 veces la de la fase en previsi n de un tercer arm nico dominante El filtro de 4 hilos puede emplearse tambi n en instalaciones industriales con o sin cargas monof sicas pero con neutro Dimensionado Una de las cuestiones previas al dimensionado es elegir las prestaciones que debe cubrir el filtro como son la compensaci n de Corrientes arm nicas Pueden compensarse los arm nicos impares de orden 3 a 49 sin embargo a partir del arm nico 25 se reduce la corriente de filtrado progresivamente hasta el 50 de su capacidad para el arm nico 49 Adem s por software es posible elegir para cada arm nico el porcentaje de compensaci n Esta funci n es de gran inter s ya que permite reducir o eliminar preferentemente aquellos arm
8. F unipolar Icn XLPE PVC XLPE PVC XLPE XLPE XLPE I I L L n x mm kvar A mm mm mm mm fase A A 10 25 6 10 6 10 6 4 10 63 35 1275 31 10 16 10 16 6 6 63 50 15 38 10 16 16 16 10 10 63 50 175 44 16 25 16 25 16 10 63 63 20 50 16 25 25 35 16 16 125 80 25 63 25 35 25 50 25 25 125 100 30 75 39 50 35 70 35 25 125 100 35 88 50 70 50 70 35 35 35 125 125 40 100 50 70 70 95 50 50 35 160 160 45 113 70 95 70 120 70 50 50 160 160 50 126 70 95 95 120 70 70 50 250 200 55 138 95 120 95 70 70 70 250 200 60 151 95 120 95 95 70 250 200 62 5 157 95 120 95 95 70 250 200 65 163 95 120 95 95 70 250 224 70 176 120 150 120 95 95 250 224 75 188 120 150 120 120 95 400 250 80 201 150 185 150 120 120 400 315 87 5 220 185 185 150 150 120 400 315 90 226 185 240 150 150 120 400 315 100 251 240 240 185 185 150 400 395 110 276 240 240 185 400 395 120 301 240 240 185 630 400 150 377 300 2X120 630 500 170 427 2X150 630 630 180 452 2X150 800 630 200 503 2X185 800 800 220 553 2X240 800 800 250 628 2X240 1000 800 275 690 ADVERTENCIAS 3X185 1000 1000 300 753 3X185 1250 1000 325 816 Utilizar con preferencia el cable 3X240 1250 1250 XLPE 90 C 350 879 3X240 1250 1250 375 941 4X185 1600 1250 400 1004 4X240 1600 425 1067 4X240 1600 450 1130 B1 Cables unipolares bajo tubo AX240 1600 475 1192 B2 Cables tripulares bajo tubo 5X240 2000 500 1255 C Cables tripulares sobre pared 5X240 2000 525 1318 E Cables tripulares sobre 5X240 2000 550 1381 bandeja perfor
9. e P rdidas P gina 31 e Protecci n IP30 e Montaje mural hasta 25 kvar o sobre suelo a partir de 50 kvar e Acometida inferior e AutoTrafo de maniobra 400 230V a partir de 50 kvar e Protecci n t rmica e Acabado RAL 7035 EF400 12 5 25 la reactancia incorpora un contacto t rmico NC para actuar sobre un dispositivo de corte exterior EF400 50 100 equipados con ventilaci n forzada incorporan el contacto t rmico de la reactancia y un termostato para conectar el ventilador Lista de Precios 2014 Condensadores Capacitors with reactor and fuses for detuned filter circuits tr 189Hz They have capacitors with serial connected reactors forming a L C filter tuned to 189Hz for 50Hz mains frequency These filters are recommended for the fixed compensation of motors or transformers transformer reactive power in installations containing harmonics They avoid the capacitors overload and they eliminate the possibility of resonance At the same time they reduce the harmonic currents and voltages in approximately 25 Technical data e Capacitors technical data page 8 e Reactor to form a detuned filter tuned to fr 189Hz e General H R C fuses are included e General switch disconnector as extra e Losses Page 31 e Protection IP30 e Wall up to 25 kvar or floor mounting from 50 kvar e Supply entry from the below e Autotransformer for aux voltage 400 230V from 50 kvar e Thermal protection e Painting colour
10. si otras unidades en paralelo en la red alimentada por un transformador de 1000 kvA u 6 a Transitorio de corriente b Transitorio de tension 5 i ee 7 45 345 E A amp JZ m en LL Se bh gt Pa a 7 m LE ML Eu E l E Ld MIA com T a n de 4dF 3 CYDESA Expertos en energ a reactiva y arm nicos Transient connection Connecting a capacitor to the network is a high current peak at the initial time could speak of a short circuit whose current is limited only by the impedance above the network connection point If additional capacitors connected in parallel with the current contribution of these can be reached peaks of up to 250 times the rated current of the capacitor For the estimate of the point of connection can be used expressions shown in Figure 6 3 To limit this phenomenon reactors or resistors can be used as shown in Figure 6 2 The limitation for reactors is used in both low and medium voltage while the previous resistance system is generally limited to low voltage suitable contactors The current limiting capacitor connection is required to avoid tripping of protections as well as preventing the occurrence of transients that affect the entire network Temporary connection of a capacitor 50kvar 400V if other units in parallel in the network supplied by one transformer 1000 kvA u 6 a surge current b Transient vo
11. 0 1 0 10 Fig 6 3 Transient current of capacitors A individual capacitor B capacitor connected in parallel i peak value of the inrush current of the capacitor A I rms value of the rated current of the capacitor A 9 Short circuit power MVA in the capacitor connection point O Battery power MVAr U voltage kV Xc Capacitive reactance in series per phase X Inductive reactance per phase between batteries F Frequency of transient F Mains frequency O Capacitors output in parallel with O MVAr Example Suppose in figure 6 3 a power transformer of 1000kVA 400V 6 and 25kvar 400V power capacitor 2Q N3U225 N3x0 42 36A S S u 2 1 0 06 MVA 36 V 2 x 16 7 0 025 1316 A 26 CYDESA Experts in reactive energy and harmonics 101 Tablas y formulario Tables and formularies Manual T cnico_Tablas y formulario Tablas y Formulario Tables and Formularies Tabla Compensaci n de transformadores Potencia reactiva de condensadores recomendada para compensaci n de la reactiva propia del transformador se supone que el trafo est al 80 de su potencia nominal Table Transformer compensation Reactive power of recommended capacitors to compensate the transformer reactive power we assume that the transformer Is being used at a rate of 80 of its rated power Compensaci n de transformadores Transformer compensation
12. 0 421 0 458 0 499 0 547 0 608 0 750 0 72 0 81 0 104 0 240 0 268 0 298 0 329 0 361 0 395 0 432 0 473 0 521 0 581 0 724 0 70 0 82 0 078 0 214 0 242 0 272 0 303 0 335 0 369 0 406 0 447 0 495 0 556 0 698 0 67 0 83 0 052 0 188 0 216 0 246 0 277 0 309 0 343 0 380 0 421 0 469 0 530 0 672 0 65 0 84 0 026 0 162 0 190 0 220 0 251 0 283 0 317 0 354 0 395 0 443 0 503 0 646 0 62 0 85 0 000 0 135 0 164 0 194 0 225 0 257 0 291 0 328 0 369 0 417 0 477 0 620 0 59 0 86 0 109 0 138 0 167 0 198 0 230 0 265 0 302 0 343 0 390 0 451 0 593 0 57 0 87 0 082 0 111 0 141 0 172 0 204 0 238 0 275 0 316 0 364 0 424 0 567 0 54 0 88 0 055 0 084 0 114 0 145 0 177 0 211 0 248 0 289 0 337 0 397 0 540 0 51 0 89 0 028 0 057 0 086 0 117 0 149 0 184 0 221 0 262 0 309 0 370 0 512 0 48 0 90 0 029 0 058 0 089 0 121 0 156 0 193 0 234 0 281 0 342 0 484 0 46 0 91 0 030 0 060 0 093 0 127 0 164 0 205 0 253 0318 0 456 0 43 0 92 0 031 0 063 0 097 0 134 0 175 0 223 0 284 0 426 0 40 0 93 0 032 0 067 0 104 0 145 0 192 0 253 0 395 0 36 0 94 0 034 0 071 0 112 0 160 0 220 0 363 0 33 0 95 0 037 0 078 0 126 0 186 0 329 0 29 0 96 0 041 0 089 0 149 0 292 0 25 0 97 0 048 0 108 0 251 0 20 0 98 0 061 0 203 0 14 0 99 0 142 Determinaci n del factor f para el c lculo de la potencia necesaria de Determination of f factor for the calculation of the required power of capacitors condensadores O Para el c lculo se halla primero tan q 0 reactiva P O In order to find this value we have to find first of all the ta
13. 0 5 0 7 5 10 0 18 5 25 5 0 7 5 10 0 125 22 30 7 5 7 5 10 0 15 0 30 40 10 0 10 0 125 15 0 37 50 10 0 12 5 15 0 22 5 45 60 125 15 0 15 0 22 9 55 75 15 0 20 0 20 0 25 0 75 100 20 0 250 30 0 30 0 90 125 20 0 30 0 35 0 40 0 110 150 30 0 40 0 40 0 45 0 132 180 35 0 40 0 50 0 60 0 160 220 35 0 50 0 60 0 80 0 200 270 40 0 60 0 70 0 90 0 250 340 50 0 80 0 100 0 110 0 315 428 60 0 90 0 110 0 135 0 655 483 90 0 100 0 125 0 160 0 400 544 100 0 125 0 150 0 175 0 450 612 100 0 1250 150 0 225 0 500 680 100 0 150 0 175 0 250 0 560 761 125 0 175 0 200 0 215 0 630 857 125 0 175 0 200 0 300 0 Para potencias superiores considerar el 30 de la potencia en kW del motor O kvar 0 3 P kW Oc Potencia reactiva en kvar m xima del condensador para compensaci n sin riesgo de autoexitaci n El Cosq obtenido es superior o igual a 0 95 La tabla ha sido confeccionada considerando los principales fabricantes de motores del mercado For higher power considering 30 of the engine power in kW O kvar 0 3 P kW Oc Reactive power in kvar capacitor for maximum compensation without risk of self excitation The Cos obtained is greater than or equal to 0 95 The table has been prepared considering the major motor manufacturers in the market CYDESA Experts in reactive energy and harmonics 81 La potencia de condensadores de la tabla ll corresponde a la recomendacion de EN 60831 1 de no superar el 90 de la potencia reactiva de vacio Esta recomend
14. 00 175 25 3x50 2 12 1000x600x400 85 ED 400 175 4 7 3 931 00 400 59200 200 2x25 3x50 242 1000x600x400 86 ED 400 200 5 8 4 314 00 630 607 00 Otros suplementos e Para interruptor autom tico y diferencial ver p g 63 Other extra prices AS A N 00 Ml VAR Va e Residual current circuit breaker on page 63 CYDESA Experts in reactive energy and harmonics Bater as de condensadores estandar EL 400V 50Hz Caracteristicas e Caracteristicas generales en pag 44 e Con regulador FPM ver pag 22 e Condensadores ver pag 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Autotrafo de maniobra 400 230V e Acometida por la parte inferior e Protecci n diferencial opcional e Fijaci n sobre suelo Lista de Precios 2014_Equipos Standard capacitor bank EL 400V 50Hz Technical data e Technical data on page 44 e With series FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Autotrans for aux voltage 400 230V e Incoming at the bottom e Optional residual current protection e Floor mounted 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio Size Price kvar 400V kvar 440V mm kg A 212 5
15. 100 SF 2 202 00 120 250 224 800x600x250 37 EC 400 120 SF 2 114 00 120 EC 400R 120 SF 2 410 00 230V 50Hz Ejecucion Prismatica Prismatic Equipment 10 160 40 520x 260 312 x135 38 5 PhP 230 10 SF 597 00 15 160 63 520x 260 312 x135 9 PhP 230 15 SF 720 00 20 160 80 520x 260 312 x135 11 PhP 230 20 SF 875 00 25 160 100 720x 260 312 x135 12 PhP 230 25 SF 1 074 00 30 160 125 720x 260 312 x135 13 PhP 230 30 SF 1 226 00 35 160 160 720x 260 312 x135 15 PhP 230 35 SF 1 356 00 peso correspondiente a ejecuci n reforzada accionamiento del seccionador en el interior del armario Leer m s en la p gina siguiente gt gt CYDESA Expertos en energ a reactiva y arm nicos weight corresponding to the higher rated equipments switch disconnector handel inside the cabinet Read more on the next page gt gt Price List 2014 Capacitors Dimensiones Terminales Ejecucion en caja EC Equipment with EC Cabinet Ejecucion Prismatica Prismatic Equipment o LEZ LA H ET e Jh B o 2 lo a H o IE 150 Condensadores prismaticos con interruptor automatico Los condensadores PhP IA incorporan un interruptor autom tico de alto poder de ruptura Resultan la soluci n id nea para compensaci n de receptores individuales Caracter sticas generales p g 8 Acabado RAL 7032 PhP RAL 7035 EC e Protecci n IP40 PhP IP30 EC Caracteristicas del interruptor automatico e Si el condensador
16. 2006 Tipo de suministro Baja tensi n U lt 1kV Media tensi n 1kV lt U lt 36kV Alta tensi n 36kV lt U lt 72 5kV Alta tensi n 72 5kV lt U lt 145kV Muy Alta tensi n U gt 145kV Un estudio de ZVEI de Marzo de 2006 para Europa EU25 propone pasar de un cosq medio en las redes de 0 91 a 0 97 con lo que en 2002 se hubiera ahorrado 18TWh o sea 18 000 millones de kWh anuales Cifra que extrapolada a Espana redundar a en 1 8TWh cifra superior a la producci n de una central de 250MW funcionando 6600h al ano Redundando en un ahorro de emisiones de gases de efecto invernadero de 772 miles de toneladas por ano as emisiones de Gases de Efecto Invernadero GEI Los principales componentes de los GEI son el di xido de carbono CO2 metano CH4 y xido nitroso N20 en conjunto representan el 9996 de los GEI De ellos el CO2 representa el 8496 del total motivo por el que al tratar de emisiones nos refiramos a emisiones de CO2 o equivalentes El protocolo de Kyoto de 1997 supuso un compromiso para la reducci n de GEI de los 38 pa ses m s industrializados durante el per odo 2008 2012 respecto a las de 1990 Esta reducci n supone el 8 para la UE la cual a su vez asign a Espana un aumento del 1596 Sin embargo Espana ha aumentado las emisiones un 52 996 en 2005 respecto a 1990 de ah la dificultad para cumplir con Kyoto lo cual obliga a adquirir derechos de emisi n seg n los mecanismos contemplados en dicho p
17. 270 00 25 86 x 300 2 0 PhMKP 400 25 54 303 00 230V 50Hz Conexi n por terminal faston o brida Protecci n IPOO 6 IP20 con cubrebornes resistencias de descarga sueltas 1 Fast on or clamp terminal connection Protection IPOO or IP20 with terminal cover discharge resistors included 1 275 64 x 190 0 8 PhMKP 230 2 5 00 2 103 00 CAP 64 5 00 5 64 x 265 1 1 PhMKP 230 5 00 2 144 00 CAP 64 5 00 10 84 x 265 19 PhMKP 230 10 00 3 271 00 CAP 84 6 00 Con cable de conexi n de 500 mm de longitud Protecci n IP54 resistencias de descarga incorporadas 1 With connection cable of 500 mm in length Protection IP54 discharge resistors assembled 1 2 5 66 x 225 0 9 PhMKP 230 2 5 54 130 00 5 66 x 300 1 2 PhMKP 230 5 54 172 00 10 86 x 300 2 0 PhMKP 230 10 54 293 00 IPOO IP20 50 m 84 IPOO IP20 1 Descarga a 50 V en 1 min excepto en protecci n IP54 75 V 3 min 2 Conexi n por terminal faston 3 Conexi n por terminal tipo brida 10 CYDESA Expertos en energ a reactiva y arm nicos 500 IP5A Price List 2014 Capacitors Cylindrical Capacitors Technical data on page 8 Discharge resistor for 50V 1 min IPOO or 75V 3 min IP54 Potencia Dimensiones Peso Tipo Precio Cubrebornes Precio Output Dimensions Weight Type Price Terminal cover Price kvar mm x h kg Protection IP20 440V 50Hz Conexi n por terminal faston o brida Protecci n IPOO IP20 con tapa de protecci
18. 2x50 3x100 478 2200x1200x800 651 EGTF 400 425 6 17 22 496 00 1000 2 347 00 450 50 4x100 506 2200x1200x800 667 EGTF 400 450 5 9 23 620 00 1000 2 347 00 475 25 50 4x100 534 2200x1800x800 719 EGTF 400 475 6 19 24 183 00 1000 2 347 00 500 2x50 4x100 562 2200x1800x800 733 EGTF 400 500 6 10 24 745 00 1250 2 636 00 525 25 2x50 4x100 591 2200x1800x800 752 EGTF 400 525 7 21 25 870 00 1250 2 636 00 550 50 5x100 619 2200x1200x800 714 EGTF 400 550 6 11 26 995 00 1250 2 636 00 575 25 50 5x100 647 2200x1800x800 715 EGTF 400 575 7 23 27 557 00 1250 2 636 00 600 6x100 675 2200x1800x800 817 EGTF 400 600 6 6 29 244 00 1250 2 636 00 600 2x50 5x100 675 2200x1800x800 821 EGTF 400 600 7 12 30 369 00 1250 2 636 00 625 25 2x50 5x100 703 2200x1800x800 886 EGTF 400 625 8 25 31 494 00 1600 2 985 00 650 50 6x100 731 2200x1800x800 977 EGTF 400 650 7 13 33 743 00 1600 2 985 00 675 25 50 6x100 WSS 2200x1800x800 986 EGTF 400 675 8 27 35 993 00 1600 2 985 00 700 2x50 6x100 787 2200x1800x800 1011 EGTF 400 700 8 14 38 242 00 1600 2 985 00 1 La potencia til Nc es la realmente entregada a la red e igual a la del condensador una vez deducida la potencia reactiva de la reactancia y la correcci n por la tensi n realmente aplicada al condensador CYDESA Expertos en energ a reactiva y arm nicos 1 The reactive output Nc is the reactive power supplied to the network and is equivalent to the capacitor output when the reactor reactive power and the correction
19. 500x400x200 13 Capacitor Bank Basic 440V 50Hz In one step Technical Data e Wall mounted e Capacitors ESTAprop e Contactors with resistors prior to current limiting connection e Relay for switching reactive contactors e Disconnection system visible through MCB 16 to 25A depending on power e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 Tipo Precio Type Price BASIC 5 613 00 BASIC 10 632 00 BASIC 12 645 00 BASIC 15 681 00 BASIC 20 739 00 BASIC 25 760 00 Capacitor Bank BasicPlus 50HZz In 2 steps Technical Data e Wall mounted e With Series controller Masing FPM e Capacitors ESTAprop e Contactors with resistors prior to current limiting connection Only 2 steps e Switch disconnector e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 e Incoming at the bottom e Acceptable ambient temperature 5 C to 35 C average in 24h maximum 40 C Tipo Precio Type Price BASICPLUS 6 1 188 00 BASICPLUS 9 1 197 00 BASICPLUS 12 1 206 00 BASICPLUS 15 1 224 00 BASICPLUS 18 1 232 00 BASICPLUS 21 1 270 00 BASICPLUS 24 1 280 00 BASICPLUS 27 1 296 00 BASICPLUS 30 1 332 00 39 CYDESA Experts in reactive energy and harmonics 40 Bateria de condensadores Basic 230V 5OHz de un solo escal n Caracteristicas e Fijaci n mural e Condensadores ESTAprop e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Re
20. 514 00 1250 2 708 00 550 11x50 666 792 2000x1200x600 349 EG 400P 550 11 11 16 605 00 1250 2 708 00 575 25 11x50 696 828 2000x1200x600 352 EG 400P 575 12 23 17 219 00 1250 2 708 00 600 12x50 726 864 2000x1200x600 357 EG 400P 600 12 12 17 267 00 1250 2 708 00 625 25 2x50 5x100 756 900 2000x1200x600 366 EG 400P 625 8 25 18 022 00 1600 2 980 00 650 50 6x100 787 936 2000x1200x600 369 EG 400P 650 7 13 18 259 00 1600 2 980 00 675 25 50 6x100 817 972 2000x1200x600 374 EG 400P 675 8 27 19 039 00 1600 2 980 00 700 2x50 6x100 847 1008 2000x1200x600 377 EG 400P 700 8 14 19 281 00 1600 2 980 00 725 25 2x50 6x100 877 1044 2000x1200x600 380 EG 400P 725 9 29 20 052 00 1600 2 980 00 750 50 7x100 908 1080 2000x1200x600 385 EG 400P 750 8 15 20 406 00 1600 2 980 00 775 25 1x50 7x100 938 1116 2000x1200x600 388 EG 400P 775 9 31 20 645 00 1600 2 980 00 800 2x50 7x100 968 1152 2000x1200x600 393 EG 400P 800 9 16 20 848 00 2 2 850 50 8x100 1029 1224 2100x1200x600 411 EG 400P 850 9 17 23 102 00 2 2 900 2x50 8x100 1089 1296 2100x1200x600 419 EG 400P 900 10 18 23 929 00 2 2 950 50 9x100 1150 1368 2100x1200x600 426 EG 400P 950 10 19 23 930 00 2 2 1000 2x50 9x100 1210 1440 2100x1200x600 433 EG 400P 1000 11 20 25 599 00 2 2 Otros suplementos Other extra prices e Para interruptor automatico y diferencial ver pag 65 e Residual current circuit breaker on page 65 e Suplemento por dispositivo comunicador Modbus Sotware e Modbus device S
21. 520x 260 300 x135 13 PhP 400 50 1A 25 1 337 00 CYDESA Experts in reactive energy and harmonics 15 16 Condensadores prismaticos con interruptor autom tico continuaci n Serie Est ndar Standard Series Poten Int Poder de Dimensiones cia Rel corte Dimensions Weight Output Circuit Breaking H x A A1 x B breaker capacity relay kvar A kA mm kg Peso Lista de Precios 2014 Condensadores Prismatic capacitors with circuit breaker continued Serie Reforzada Higher rated Series Tipo Precio Potencia Tipo Precio Type Price Output Type Price kvar 400V 50Hz Ejecucion Prismatica Prismatic Equipment 60 160 125 100 25 70 160 140 125 25 75 160 150 25 720x 260 300 x135 13 720x 260 300 x135 720x 260 300 x135 15 13 PhP 400 70 1A 25 16 15 PhP 400 75 1A 25 PhP 400 60 14 25 1 471 00 1 693 00 1 713 00 50 PhP 400R 50 IA 25 1 480 00 60 PhP 400R 60 IA 25 1 629 00 70 PhP 400R 70 IA 25 1 848 00 400V 50Hz Ejecuci n en caja mural Wall mounted equipment 80 250 160 36 800x600x250 99 100 250 200 36 800x600x250 35 120 250 240 36 800x600x250 37 valores correspondientes a ejecuci n reforzada Dimensiones Terminales Ejecuci n Prism tica PhP Prismatic Equipment PhP Ejecuci n en caja EC Equipment with EC Cabinet p pp AAA O ZA p AAA B OUA PEA PAPA AAA H e 150 Pd eo a GM A A1 Condensador prism tico Prismatic capacitor Condensador prism
22. 7 226 00 630 840 00 140 20 3x40 1890x580x445 163 EL 230 140 4 7 7 870 00 630 840 00 150 10 20 3x40 1890x580x445 165 EL 230 150 5 15 8 198 00 630 840 00 170 10 8x20 1890x 1160x445 256 EL 230 170 9 17 10 500 00 630 840 00 180 20 4x40 1890x 1160x445 258 EL 230 180 5 9 10 860 00 800 1 221 00 200 2x20 4x40 1890x 1160x445 263 EL 230 200 6 10 11 673 00 800 1 221 00 220 20 5x40 1890x 1160x445 268 EL 230 220 6 11 12 726 00 800 1221500 250 1x10 2x20 5x40 1890x 1160x445 271 EL 230 250 8 25 13 926 00 Equipments at other voltages and or frequencies Bajo demanda fabricamos equipos a 690V 50Hz y 1050V 50Hz We manufacture equipments at 690V 50Hz and 1050V 50Hz as asi como a tensiones especiales Disponemos tambi n de well as special voltages on request We also have equipments ejecuciones a 60Hz at 60Hz Equipos a otras tensiones y o frecuencias 52 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Instalaci n compensada por CYDESA Facilities compensated by CYDESA 1 Tren de alta velocidad espanol 1 Spanish high speed train 2 Circuito automovil stico de Valencia 2 Racing circuit of Valencia 3 Exposici n Internacional Agua y Desarrollo Sostenible en Zaragoza 3 International Expo Water and Sustainable Development in Zaragoza CYDESA Experts in reactive energy and harmonics 53 54 Con frecuencia las condiciones de servicio de los equipos con condensadores sup
23. 89 inrush reactors and H R C fuses Optionally they can also have a switch disconnector an earthing switch and light voltage indicators Equipment EG with contactor This solution eliminates the self excitation risk if the capacitor is disconnected simoultanoeusly with the motor provided that the capacitor is connected to the motor terminals and the operation is carried out by means of an auxiliary contact of the motor contactor The automatic switching operation with a reactive power controller is also possible The basic equipment consists of a three phase capacitor with a pressure sensor with a contact that acts on the contactor a vacumm contactor inrush reactors and H R C fuses Optionally they can also have an earthing switch and light voltage indicators Automatic compensation equipments The basic equipment consists of capacitors inrush reactors H R C fuses vacuum contactors and a controller to operate the steps automatically depending on the mains reactive demand and the target cosq Optionally they can also have a circuit breaker an earthing switch and light voltage indicators Equipments with harmonic filters All the equipments can include either detuned filters for harmonics at a tuned frequency of 189Hz or absorption filters tuned to frequencies close to the harmonics that have to be absorbed Technical handbook Equipo de compensaci n autom tica de 230 460 920 kvar a 4 16 kV 50 Hz 1c fs
24. 941 0 982 1 030 1 090 7283 1 20 0 64 0 451 0 581 0 716 0 745 0 775 0 805 0 838 0 872 0 909 0 950 0 998 1 058 1 201 1 17 0 65 0 419 0 549 0 685 0 714 0 743 0 774 0 806 0 840 0 877 0 919 0 966 1 027 1 169 1 14 0 66 0 388 0 519 0 654 0 683 0 712 0 743 0 775 0 810 0 847 0 888 0 935 0 996 1 138 1 11 0 67 0 358 0 488 0 624 0 652 0 682 0 713 0 745 0 779 0 816 0 857 0 905 0 966 1 108 1 08 0 68 0 328 0 459 0 594 0 623 0 652 0 683 0 715 0 750 0 787 0 828 0 875 0 936 1 078 1 05 0 69 0 299 0 429 0 565 0 593 0 623 0 654 0 686 0 720 0 757 0 798 0 846 0 907 1 049 1 02 0 70 0 270 0 400 0 536 0 565 0 594 0 625 0 657 0 692 0 729 0 770 0 817 0 878 1 020 0 99 0 71 0 242 0 372 0 508 0 536 0 566 0 597 0 629 0 663 0 700 0 741 0 789 0 849 0 992 0 96 0 72 0 214 0 344 0 480 0 508 0 538 0 569 0 601 0 635 0 672 0 713 0 761 0 821 0 964 0 94 0 73 0 186 0 316 0 452 0 481 0 510 0 541 0 573 0 608 0 645 0 686 0 733 0 794 0 936 0 91 0 74 0 159 0 289 0 425 0 453 0 483 0 514 0 546 0 580 0 617 0 658 0 7 06 0 766 0 909 0 88 0 75 0 132 0 262 0 398 0 426 0 456 0 487 0 519 0 553 0 590 0 631 0 679 0 739 0 882 0 86 0 76 0 105 0 235 0 371 0 400 0 429 0 460 0 492 0 526 0 563 0 605 0 652 0 713 0 855 0 83 0 77 0 079 0 209 0 344 0 373 0 403 0 433 0 466 0 500 0 537 0 578 0 626 0 686 0 829 0 80 0 78 0 052 0 183 0 318 0 347 0 376 0 407 0 439 0 474 0 511 0 552 0 599 0 660 0 802 0 78 0 79 0 026 0 156 0 292 0 320 0 350 0 381 0 413 0 447 0 484 0 525 0 573 0 634 0 776 0 75 0 80 0 130 0 266 0 294 0 324 0 355 0 387
25. 950 00 1600 2 980 00 Instalaci n compensada por CYDESA Facilities compensated by CYDESA 1 Aeropuertos 1 Airports 2 Centros comerciales 2 Shopping malls CYDESA Experts in reactive energy and harmonics 59 Det puede estimarse del orden del 25 h xe s Capacitor bank ECF EDF with detuned filter circuits el Lee tr 189H7z Equipo serie ED These equipments have L C filters tuned to 189Hz which is equivalent to a harmonic order Equipment of the ED series of hr 3 78 and a reactor factor of p 7 The main duty of these filters is to compensate the reactive energy but they also absorb harmonic currents mainly of 5th harmonic and therefore they reduce the harmonic voltages This reduction can be considered approximately of 25 Caracteristicas Technical Data Tension de red 400V 50 Hz Mains voltage 400V 50 Hz Tensiones arm nicas US 0 5 UN Allowed harmonic voltages U3 0 5 Un admisibles UBSUTES UN U5 U7 5 Un Sobrecorriente admisible 5 Irms Allowed overcurrent at 5 Irms a 50 Hz 50 Hz P rdidas max totales 6 W kvar Max losses approx 6 W kvar aprox Regulador FPM Controller type FPM Autotrafo de maniobra 400 230V Autotransf for auxiliar 400 230V voltage Acometida Inferior Incoming At the bottom Ventilaci n Forzada Cooling Forced Temperatura ambiente 15 C max 40 C max 35 Ambient temperature 15 C max 40 C max 35 de media en 24h average on 24h Altitud 1000 m Sobre nivel Altitude 1000 m Above sea
26. EGF 400 375 5 15 16 872 00 800 1 584 00 400 2x50 3x100 450 2200x1200x800 580 EGF 400 400 5 8 17 154 00 1000 2 347 00 425 25 2x50 3x100 478 2200x1200x800 605 EGF 400 425 6 17 17 997 00 1000 2 347 00 450 50 4x100 506 2200x1200x800 620 EGF 400 450 5 9 18 279 00 1000 2 347 00 475 25 50 4x100 534 2200x1200x800 640 EGF 400 475 6 19 19 121 00 1000 2 347 00 e Residual current circuit breaker on request See page 65 1 See note at the bottom of page 32 e Para interruptor autom tico y diferencial ver p g 65 1 Ver nota a pie de p gina 32 62 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Bater as de condensadores EGF con filtros de rechazo fr 189 Hz continuaci n Capacitor bank EGF with detuned filter circuits fr 189 Hz continued 400V 50Hz Potencia util Potencia Dimensiones Peso Tipo Precio Suplemento Reactive output nominal Dimensions Weight Type Price int de corte Nc 1 Rated output HxAxB Extra price for Composici n Composition On 1 switch disco Calibre Precio Size Price kvar 400V kvar 440V mm kg A 500 2x50 4x100 562 2200x1200x800 780 EGF 400 500 6 10 20 246 00 1250 2 636 00 550 50 5x100 619 2200x1200x800 820 EGF 400 550 6 11 20 809 00 1250 2 636 00 600 2x50 5x100 675 2200x1200x800 860 EGF 400 600 7 12 22 496 00 1250 2 636 00 650 50 6x100 731 2200x1800x800 395 EGF 400 650 7 13 26 995 00 1600 2 985 00 700 2x50 6x100 787 2200x1800x800 939 EGF 400 700 8 1
27. EGF series Caracter sticas Technical Data Tensi n de red 400V 50 Hz Mains voltage 400V 50 Hz Potencias Est ndar hasta 800 kvar Outputs Standards up to 800 kvar Tensiones arm nicas U3 0 5 Un Allowed harmonic voltages U3 0 5 Un admisibles SUITES UN U5 U7 5 Un Sobrecorriente admisible 5 Irms Allowed overcurrent at 5 Irms a 50 Hz 50 Hz P rdidas max totales aprox 6 W kvar Max Losses approx 6 W kvar Regulador FPM Controller type FPM Autotrafo de maniobra 400 230V Autotrans for aux voltage 400 230V Acometida Inferior Supply entry Below Ventilaci n Forzada Cooling Forced Temperatura ambiente 15 C max 40 C max 35 Ambient temperature 15 C max 40 C max 35 de media en 24h average on 24h Altitud 1000m Sobre nivel del mar Altitude 1000 m Above sea level Protecci n IP 30 Protection IP 30 Acabado RAL 7035 Painting colour RAL 7035 400V 50Hz Potencia util Potencia Dimensiones Peso Tipo Precio Suplemento Reactive output nominal Dimensions Weight Type Price int de corte Nc 1 Rated output HxAxB Extra price for Composici n Composition On 1 switch disco Calibre Precio Size Price kvar 400V kvar 440V mm kg A 300 2x25 1x50 2x100 337 2200x1200x800 520 EGF 400 300 5 12 14 194 00 630 1 584 00 325 25 2x50 2x100 366 2200x1200x800 530 EGF 400 325 5 13 15 185 00 800 1 584 00 350 50 3x100 393 2200x1200x800 550 EGF 400 350 4 7 15 467 00 800 1 584 00 375 25 50 3x100 421 2200x1200x800 570
28. HUA hl Ta pili phn lalala NL OST Es om T O Ed 3 d m D Ear E a E F MA e Automatic compensation equipments of 230 460 920 kvar at 4 16 kV 50 Hz CYDESA Experts in reactive energy and harmonics 99 100 Manual t cnico Perturbaciones debidas a los condensadores Disturbances due to capacitors Transitorio de conexi n La conexi n de un condensador a la red supone una punta de corriente elevada en el instante inicial podr a hablarse de un cortocircuito cuya corriente queda s lo limitada por la impedancia red arriba del punto de conexi n Si existen otros condensadores conectados en paralelo con la aportaci n de corriente de estos pueden alcanzarse puntas de hasta 250 veces la corriente nominal del condensador Para el c lculo aproximado de la punta de conexi n puede utilizarse las expresiones indicadas en la figura 6 3 Para limitar este fen meno puede emplearse inductancias o resistencias como se indica en la figura 6 2 La limitaci n por inductancia se utiliza tanto en baja como en media tensi n mientras que el sistema de resistencias previas se limita en general a baja tensi n con contactores apropiados La limitaci n de la corriente de conexi n de condensadores es necesaria para evitar el disparo de protecciones as como impedir la aparici n de transitorios que afecten a toda la red Transitorio de conexi n de un condensador de 50kvar 400V
29. RAL 7035 EF400 12 5 25 the reactor has a thermal contact NC in order to act on a breaking outer device EF400 50 100 equipped with forced cooling they have the thermal contact and a thermostat to switch on the fan 400V 50Hz Potencia Dimensiones Peso Tipo Suplemento por interruptor Output Dimensions Weight Type Extra price for switch HxAxB disconnector In Precio Calibre Precio kvar Price Size Price 400V mm kg A 12 5 700 x 500 x 250 43 EF 400 12 5 1 509 00 63 205 00 25 700 x 500 x 250 53 EF 400 25 1 813 00 63 209 00 Con ventilaci n forzada With forced cooling 50 800 x 600 x 300 1 82 EF 400 50 2 930 00 125 247 00 75 1150 x 600 x 400 100 EF 400 75 4 238 00 160 263 00 100 1300 x 600 x 660 170 EF 400 100 5 744 00 250 341 00 1 El equipo de 50kvar se suministra con pies de 150mm de altura CYDESA Expertos en energ a reactiva y arm nicos 1 The equipment of 50kvar equipment is provided with feet of 150mm of height Price List 2014 Capacitors Condensadores con reactancias Dimensiones Condensadores con reactancias Esquema el ctrico Capacitors with reactor and fuses Dimensions Capacitors with reactor and fuses Wiring diagram QR EF400 12 5 25 EF400 50 100 Fabricantes de condensadores y baterias de condensadores Manufacturers of capacitors and capacitor banks in low and en baja y media tension desde 1976 medium voltage since 1976 CYDESA Experts in reactive energy and harmonics 19
30. al horno a 150 Caracteristicas e Clase de aislamiento F 155 C e Temperatura ambiente m xima admisible 50 C e Tolerancia de la L 2 3 de LN e Sobrecarga admisible U1 6 U3 0 5 U5 U7 5 relativa a Un Ith 1 05 Irms e Limite de linealidad L a 1 2 l 0 95LN e Control de temperatura por microcontacto NC en el inte rior del devanado e Ejecuci n interior IPOO e Tensi n de ensayo entre devanado y n cleo 3 kV 1 min e Norma CEl 60076 CYDESA Expertos en energ a reactiva y arm nicos Reactors for detuned filter circuits frz189Hz Three phase reactors with iron core and coil of copper or aluminium and copper terminals Impregnated under vacuum over pressure in polyester resin and dried under furnace temperature of 150 Technical data e Insulation class F 155 C e Maximum ambient temperature 50 C e Tolerance L 2 3 of LN e Allowed overvoltage and overcurrent U1 6 U3 0 5 U5 U7 5 regarding Un Ith 1 05 Irms e Limit of linearity L at 1 2 gt 1 gt 0 95LN e Temperature control by one microswitch NC in the inner coil e POO for indoor use e Test voltage between coil and core 3 kV 1 min e Standard IEC 60076 Price List 2014 Capacitors Reactancias para filtros de rechazo para arm nicos fr 189HZ Reactors for detuned filter circuits fr189Hz 400V 50Hz Potencia util Dimensiones Peso P rdidas Losses Inductancia Tipo Precio del condensador Dimensions Wei
31. armario de poli ster RAL 7035 Protecci n mec nica IP30 e Acometida por la parte inferior e Temperatura ambiente admisible 5 C a 35 C media en 24h m ximo 40 C 230V Potencia Composici n Dimensiones Calibre Output Composition Dimensions int HxAxB kvar mm A 7 5 2 5 5 500x400x200 63 12 5 2 5 2x5 500x400x200 63 15 3x5 500x400x200 63 20 4x5 600x500x250 125 25 5 2x10 600x500x250 125 30 3x10 600x500x250 125 35 5 3x10 800x600x300 160 37 5 7 5 3x10 800x600x300 160 40 4x10 800x600x300 160 45 3x15 800x600x300 160 50 10 2x20 800x600x300 250 Bater a de condensadores Prosec 230 V 5OHz de 60 a 80 kvar Caracter sticas e Fijaci n sobre suelo e Con regulador de la serie Masing FPM e Condensadores ESTAprop e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Interruptor tripolar de corte en carga e Montado en armario de poli ster RAL 7035 Protecci n mec nica IP30 e Acometida por la parte inferior e Temperatura ambiente admisible 5 C a 35 C media en 24h m ximo 40 C Capacitor Bank Prosec 230 V 50Hz up to 50 kvar Technical Data e Wall mounted e With Series controller Masing FPM e Capacitors ESTAprop e Contactors with resistors prior to current limiting connection Only 2 steps e Switch disconnector e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 e Incoming at the bottom e Acceptable ambient temperature
32. current e Incoming at the bottom e Caracter sticas generales en p g 44 e Fijaci n sobre pared EC o suelo ED e Con regulador FPM ver p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Acometida por la parte inferior 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio kvar kvar kvar Size Price 400V 440V 480V mm kg A 20 7 4 1 2x8 3 25 30 500x400x200 24 EC 400P 20 7 3 5 1 620 00 63 130 00 29 4 1 8 3 16 5 35 42 700x500x250 32 EC 400P 29 3 7 1 925 00 125 157 00 38 5 8 11 6 20 7 46 55 700x500x250 35 EC 400P 38 3 5 1 991 00 125 157 00 41 3 8 3 2x16 5 50 59 700x500x250 35 EC 400P 41 3 3 5 2 057 00 125 157 00 53 11 6 2x20 7 64 76 700x500x250 37 EC 400P 53 3 5 2 129 00 125 157 00 62 5 12 5 2x25 76 90 700x500x250 37 EC 400P 62 5 3 5 2 286 00 125 176 00 75 2x12 5 2x25 91 108 800x600x250 38 EC 400P 75 4 6 2 828 00 160 176 00 87 5 12 5 3x25 106 126 800x600x250 49 EC 400P 87 5 4 7 3 065 00 250 261 00 100 2x12 5 3x25 121 144 800x600x250 50 EC 400P 100 5 8 3 412 00 250 261 00 112 5 12 5 2x25 1x50 136 162 1000x600x400 75 ED 400P 112 5 4 9 4 158 00 250 500 00 125 25 2x50 151 180 1000x600x400 75 ED 400P 125 3 5 4 291 00 250 500 00 150 2x25 2x50 181 216 1000x600x400 79 ED
33. de 1kg de CO2 a la atm sfera se produce por 2 3 kWh de consumo de energ a el ctrica 7 9 km recorridos por un coche utilitario 3 3 horas en una vivienda habitada de tipo medio Al mismo tiempo por cada kvar instalado en condensadores se evitar a en un ano la emisi n de 25kg de CO2 1 1 Se trata de una estimaci n aproximada fruto de los datos disponibles _ A fi r 4 7 j t Fey B T imma a E x PEN NA Be es a 1 pe gaan TR V dc S m Da Lom wm ji e I iv ji VAS elie 3 m E ie gt oo SS 2815 ENT C o oec E OTAN a Pn a L E c um E E v T i d d F1 d ane me D E Tr a up AS AT rae i A MI i m LLL ia um PEF r e m EIU el r CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico How do electric energy kWh become CO2 emissions Electric plants except hydraulics and nuclear ones use fuel that emits greenhouse gases measured by CO2 equivalent emitted To sum up in order to produce 1kWh the following values are emitted 1Kg of CO2 on coal station 750g on a fuel oil station 300g in a combined cycles station If we take into account all kinds of stations the average in Spain in 2006 was 429 g of CO2 kWh this means that for every kWh we consume we em
34. est ticos Static contactors ESTANDAR CON CONTACTORES EST TICOS Y FILTROS STANDARD WITH STATIC CONTACTORS AND FILTERS e Regulador FPM m x 6 o 12 escalones FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector e Contactores est ticos Static contactors e Reactancias por escal n para filtros de rechazo de arm nicos 189Hz Reactors for harmonic filters Instalaciones donde las frecuentes variaciones de carga exigen un gran n mero de maniobra de los contac tores When a high frecuency of switchings are needed Instalaciones con destacada presenca de arm nicos Installations with strong presence of harmonics Para condiciones extremas de servi cio Por ejemplo tensi n y o tempera tura ambiente elevadas For extreme conditions high voltage or and ambient temperature Instalaciones donde las frecuentes variaciones de carga exigen un gran n mero de maniobras junto con con diciones extremas de servicio For high frequency of swithchings and extreme conditions high voltage or and ambient temperature Instalaciones con destacada pre sencia de arm nicos y frecuentes variaciones de carga Installations with strong presence of harmonics large load variation 1 Voltage at with the capacitor referred 2 To install at the point of common coupling 51 60 63 55 57 58 59 64 CYDESA Experts in reactive energy and harmonics 37 Lista de Precio
35. filtrado Ver pag 64 Instalaci n del FA ECOsine Active Conexi n del ECOsine Active de Compensaci n posible W No es posible compensar 3 hilos CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Sizing an active filter for harmonic filtering To determine the capacity of the active filter will proceed as follows Calculate the fundamental current in the course of which as usual the data is effective total current includes harmonics hn EME 14 THDIY Harmonic current offset is calculated by I I THDi THDi Where THDI2 is the total harmonic distortion to achieve Design example In an industrial network with a high balance in the 3 phases are measured e Line current 330 A e Current THD THDI 40 You want to reduce distortion to 10 We estimate gt I 284484 Compensate the harmonic current will be Ip I THDi THDi 284 48 0 4 0 1 85 344 Would choose EcoSine Active FN 100A 3420 100 480 3 filter capacity See page 64 FA ECOsine Active Installation ECOsine Active connection of 65hE Compensaci n posible 54 No es posible compensar 4 hilos Technical handbook En la figura se muestra la conexi n del ECOsine de 3 y 4 hilos Si los receptores son trif sicos o bien las cargas monof sicas son escasas o no causan distorsi n puede emplearse un FA de 3 hilos como indica la figura En caso contrario debe
36. filtro de arm nicos ij CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Armonicos Both in industries and in office buildings it s more and more usual to find loads that distort the current wave they absorb These currents atthe same time as a result of a simple voltage drop distort the bar voltage affecting therefore the other installation loads These distorted waves are decomposed for their analysis in its fundamental component at the mains frequency and harmonics or waves multiples of the fundamental component Among the harmonic load generators the most common are The single phase power supply characteristic of PC among others which produce harmonics mainly of the order numbers 3 5 and 7 The Adjusted Speed Drivers ASD that control the speed of induction motors usually of 6 pulse and produce harmonics mainly of the order 5 7 11 and 13 and from these ones the most significant are the 5th and the 7th The Uninterruptible Power Supply Systems UPS that in the case of 6 pulse produce the same aforementioned harmonics In short the typical harmonics are these of the order numbers 3 5 7 11 and 13 and the most significant ones are of the order 3 and 5 5 and 7 in office buildins in industries The capacitor banks are one of the more sensitive loads for harmonics absorbing them easily causing its amplification and even producing resonance problems In order to avoid the drawbacks
37. level del mar Protecci n IP 30 Protection IP 30 Acabado RAL 7035 Painting colour RAL 7035 400V 50Hz Potencia util Potencia Dimensiones Peso Tipo Precio Suplemento Reactive output nominal Dimensions Weight Type Price int de corte Nc 1 Rated output HxAxB Extra price for Composici n Composition On 1 switch disconnector Calibre Precio Size Price kvar 400V kvar 440V mm kg A 25 2x12 5 28 800x600x300 78 ECF 400 25 2 2 4 501 00 63 178 00 37 5 12 525 42 800x600x300 85 ECF 400 37 5 2 3 5 062 00 125 187 00 50 2x12 5 25 56 1300x600x660 125 EDF 400 50 3 4 5 344 00 125 187 00 62 5 12 5 2x25 70 1300x600x660 133 EDF 400 62 5 3 5 5 624 00 160 203 00 75 2x12 5 2x25 84 1300x600x660 146 EDF 400 75 4 6 6 749 00 160 203 00 100 2x25 50 2 1300x600x660 146 EDF 400 100 3 4 7 706 00 250 275 00 e Para interruptor autom tico y diferencial ver p g 65 e Residual current circuit breaker on request See page 65 1 Ver nota a pie de p gina 32 Lista de Precios 2014_Equipos 7 Y Bater as de condensadores eo con filtros Bater as de condensadores ECF EDF con filtros de recha zo fr189Hz Estos equipos incorporan filtros L C sintonizados a 189Hz lo que equivale a un orden de arm nico de hr 3 78 y un factor de reactancia p 7 La funci n principal de estos filtros es la compensaci n de la energ a reactiva si bien tambi n absorben corrientes arm nicas principalmente del 5 arm nico y por tanto reducen las tensiones
38. logra un ahorro de p rdidas de 7290 kWh por ano que a raz n de 0 10 por kWh supondr a un ahorro de 729 ano 1 Ambos conceptos coinciden en redes sin distorsi n arm nica What Is reactive energy Just like active energy reactive energy in the absence of other source will be supplied by a power plant and conducted through the network However there is another source of reactive energy affordable and easy to install in any place the electric capacitor The capacitor is a device that after choosing a suitable output supplies reactive energy without needing to be supplied by the power station For simplicity reasons and its performance capacitors or capacitor banks are the universal method used to improve the coso also called often power factor PF 1 RED If the capacitor supplies the reactive power necessary for the motor the power plant only has to supply active output P otherwise it should supply P and O What are the advantages of compensating reactive energy According what it was exposed before the main advantages of reactive energy compensation are Losses are reduced which means energy KWh saving By compensating reactive energy we avoid that this one must flow through the network partially or totally just as we choose which carry to a reduction of the flowing electric current Since losses are proportional to the square of the current the importance of this reduction is clear Fur
39. n resistencias de descargas sueltas 1 Fast on or clamp terminal connection Protection IP00 or IP20 with protective cover discharge resistors included 1 5 64 x 190 0 8 PhMKP 440 5 00 2 95 00 CAP 64 5 00 10 64 x 265 dl PhMKP 440 10 00 2 129 00 CAP 64 5 00 15 84 x 190 1 4 PhMKP 440 15 00 3 208 00 CAP 84 6 00 16 9 84 x 190 1 9 PhMKP 440 16 9 00 3 217 00 CAP 84 6 00 20 84 x 265 1 9 PhMKP 440 20 00 3 224 00 CAP 84 6 00 22 5 84 x 265 1 9 PhMKP 440 22 5 00 3 264 00 CAP 84 6 00 25 84 x 265 1 2 PhMKP 440 25 00 3 270 00 CAP 84 6 00 28 1 84 x 265 1 9 PhMKP 440 28 1 00 3 292 00 CAP 84 6 00 30 84 x 340 23 PhMKP 440 30 00 3 316 00 CAP 84 6 00 Con cable de conexi n de 500 mm de longitud Protecci n IP54 resistencias de descarga incorporadas 1 With connection cable of 500 mm in length Protection IP54 discharge resistors assembled 1 5 66 x 225 0 9 PhMKP 440 5 54 118 00 10 66 x 300 1 2 PhMKP 440 10 54 151 00 15 86 x 225 T5 PhMKP 440 15 54 233 00 20 86 x 300 2 0 PhMKP 440 20 54 254 00 25 86 x 300 2 0 PhMKP 440 25 54 291 00 525V 50Hz Conexi n por terminal faston o brida Protecci n IP00 IP20 con tapa de protecci n resistencias de descargas sueltas 1 Fast on or clamp terminal connection Protection IP00 or IP20 with protective cover discharge resistors included 1 10 64 x 265 1 4 PhMKP 525 10 00 2 126 00 CAP 64 5 00 15 84 x 190 1 4 PhMKP 525 15 00 3 191 00 CAP 84 6 00 20 84 x 265 1 9 PhMK
40. nicos que por ejemplo superen los l mites de determinadas normas o puedan causar resonancias o perturbaciones en la red Corriente reactiva Debe seleccionarse tanto el porcentaje de compensaci n como el cos de consigna Como m nimo el FA compensar el porcentaje ajustado aunque supere la consigna As si el cose de la red en un instante determinado resulta superior al cos de consigna el FA compensar igualmente el porcentaje programado Desequilibrio de corrientes Es habitual que en instalaciones con receptores monof sicos como puede ser el caso de oficinas se produzca un desequilibrio entre las corrientes de las fases Este desequilibrio puede sobrecargar los conductores de la fase m s cargada produciendo calentamientos innecesarios El FA puede programarse para corregir estos desequilibrios Atenuaci n del fliker El fliker se trata de un fen meno que causa oscilaciones de tensi n de baja frecuencia que resultan especialmente molesta por su efecto en el alumbrado y en consecuencia en el ojo humano En la medida en que el FA compense la corriente reactiva producir la correspondiente reducci n en las oscilaciones de las ca das de tensi n y por tanto del fliker Sin embargo al no alterar las oscilaciones de corriente activa esta compensaci n es evidentemente limitada Choice of active filter EcoSine Active filters are supplied in executions e 3 wire three phase systems without neutral or without phase loads the
41. receptores que consumen energ a reactiva a ese nivel de tensi n por ejemplo grandes motores M2 1 y M2 2 en la figura En baja tensi n Como es usual es donde se encuentran la mayor parte de receptores que consumen reactiva receptores a 400V alimentados por el secundario de T1 en la figura Receptor por receptor Soluci n adoptada cuando existen pocos receptores y de gran potencia por ejemplo los motores M1 M2 1 y M2 2 de la figura Tambi n es habitual conectar un condensador fijo para la compensaci n de la potencia reactiva propia de los transformadores OT1 y OT2 de la figura La compensaci n a bornes de receptor tiene la ventaja de descargar toda la red desde los terminales del receptor aguas arriba hasta la fuente a alimentaci n Con una bater a autom tica centralizada En la mayor parte de instalaciones el gran n mero de receptores aconseja compensar de forma centralizada con una bater a o equipo autom tico conectado en el embarrado general a la salida del transformador equipo O1 de la figura T1 1000kVA 6 0 4kV 1 2 3 Naves motores y varios M1 100kW Formas de compensaci n Different compensation types 78 CYDESA Expertos en energ a reactiva y arm nicos The reactive power compensation can be done at Medium voltage when there are loads that absorb reactive energy at this voltage level for example big motors M2 1 y M2 2 at the figure Low voltage it is where you ca
42. recommendation of EN 60831 1 of not overcoming the 90 of the unload reactive power This recommendation is required to avoid the motor self excitation situation produced especially in motors that can run down when they are disconnected of the network provided that the capacitor is connected to the motor terminals In other circumstances the capacitor can achieve the reactive power produced by the motor at full load Example Motor that starts a large inertia machine high risk of self excitation power 75kW for 1500 r p m The value written on the table will be taken 25 kvar for the capacitor power If the capacitor would be connected to the motor terminals but through a contactor the aforementioned limit of 90 of the unload reactive power would not be necessary Example Motor of 350 kW that drives a pump with cos at full load of 0 88 and efficiency of 97 we wish to compensate up to cos 0 97 The capacitor power is calculated as usual by the traditional formula see table Ill on page 106 QzP f In that case and according to the table mentioned above f20 289 then 350 Q 997 0 289 104 kvar The motors with a star delta starting must be compensated connecting the capacitor to the line contactor side or with an independent contactor Technical handbook En motores con arrancadores estaticos conectar el condensador antes del arrancador solucion a o b de la figura Compensacion central
43. reguladores Masing FPM destacan por su simplicidad si bien el nuevo regulador Masing Premium FPMp anade a las elevadas prestaciones del Masing FPM la medici n visualizaci n y actuaci n sobre los tres factores de potencia de la instalaci n En instalaciones desequilibradas con mayor a de cargas monof sicas se corre el riesgo cuando se mide s lo una fase que la compensaci n de la energ a reactiva no se realice correctamente El nuevo regulador Masing Premium con tres displays mide y visualiza los tres factores de potencia y compensa en funci n de su valor medio CYDESA recomienda la utilizaci n del regulador Masing Premium en instalaciones en las que las cargas monof sica inductivas sean mayoritarias Para la instalaci n de las bater as de condensadores con reguladores Masing Premium se debe preveer la instalaci n de tres transformadores de corriente para que el regulador pueda medir los tres factores de potencia CYDESA dispone de dos modelos de reguladores Masing Premium FPMp de 6 y 12 escalones Caracter sticas y mediciones e Cos inductivo y capacitivo e Tres fases tensiones y corrientes e Potencias Activa reactiva y aparente e THD en tensi n y en corriente e Horas de trabajo e Temperatura ambiente e Funcionamiento en 4 cuadrantes e Registro de los valores medidos m ximos de tensi n corriente THD y temperatura Alarmas con un rel programable Subcompensaci n sobrecompensaci n sob
44. required or if the cosq of the motor is already known the traditional calculation can be carried out Motor compensation with capacitors output limits to avoid the self excitation risk Potencia reactiva maxima para evitar la autoexcitacion en funcion del n de revoluciones por minuto Highest reactive power to avoid the self excitation depending Motor kW CV HP 3000 rpm 160 217 30 200 272 40 250 340 50 S15 428 65 400 543 80 500 679 100 1000 1350 200 1500 2040 300 2000 2720 400 3000 4075 600 4000 5434 800 5000 6793 1000 Compensacion de transformadores de M T As como en transformadores para distribuci n con secundario en baja tensi n existen valores normalizados para la corriente de vac o y la reactancia de dispersi n en M T deber consultarse los valores al fabricante o en caso de proyectos tomar valores orientativos como los indicados a continuaci n CYDESA Expertos en energ a reactiva y arm nicos on the speed of rotation 1500 rpm 1000 rpm 750 rpm 40 50 60 50 60 70 65 75 90 80 90 110 100 120 140 125 150 175 250 300 350 375 450 525 500 600 700 750 900 1050 1000 1200 1400 1250 1500 1750 M V Transformers compensation In case of transformers for the distribution with secondary in low voltage there are standardised values for the unload current and the impedance However for M V transformers the values should be asked to the manufacturer or in case of projects you can take approximate value
45. sticos pueden amplificar otros arm nicos imprevistos Su capacidad de absorci n de corrientes arm nicas se puede ver f cilmente superadas por las provinentes de otros puntos de la red sobrecargando peligrosamente el filtro Su eficacia depende de la impedancia de la red sujeta sta a cambios imprevistos La variaci n de sus caracter sticas por envejecimiento de los componentes provoca la alteraci n de la frecuencia de sintonizaci n y por tanto existe peligro de sobrecarga o destrucci n del filtro Alguno de los problemas antes apuntados permiten soluciones con dise os apropiados por ejemplo los filtros pasivos ECOsine de Shaffner que permiten compensar arm nicos de los variadores de frecuencia sin riesgo de sobrecarga El filtro activo FA no supone ninguno de los problemas antes mencionados de los filtros activos pasivos En la figura se aprecia la forma de operar de un filtro activo inyectando a la red las corrientes arm nicas seleccionadas en oposici n de fase a las existentes o generadas por las cargas distorsionantes 237 WM moe a M CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Filtros activos Traditionally to compensate harmonics are still used passive filters consisting of reactors and capacitors in various configurations Of these the most used is the series LC filter or filter tuned to the harmonic frequency to be compensated If the loads connected to the network int
46. that the voltage to be borne equipment or capacitor being connected in most cases to the same output of the transformer is higher than that assigned to the bank For this reason and for any temperature problems and or harmonics may be necessary to oversize capacitors not only but also the other components which is why we have created a series of Premium equipment Therefore ensure long life in severe service conditions Premium banks have their power referred to 400V 440V permanently and temporarily 490V Maximum reactive power compensation reliability by acting as the beacon if Cosq is below 0 95 and Modbus communication Increased life expectancy by oversizing of temporarily Capacitors voltage up to 490V In the contactors and power cables using larger than that assigned nominal Instalaci n compensada por CYDESA Feria de Madrid Madrid CYDESA Expertos en energ a reactiva y arm nicos Facilities compensated by CYDESA Feria de Madrid Madrid Price List 2014 Equipment Premium automatic capacitor banks for exteme services Premium capacitor bank EC ED 400P Bater as de condensadores Premium EC ED 400P gt 1500 B3 ai A partir de 75 kvar From 75 kvar Caracter sticas Technical data e Technical data on page 44 e Wall mounted EC or floor mounted ED e With FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on
47. working unloaded and capacitors connected The capacitor O results in an increase in voltage in a bus bars in a network of inductive reactance circuit X Reactive power variation span of a capacitor according to the withstand voltage The two most significant parameters that define a capacitor bank are the rated reactive power Or and rated voltage Ur reactive power is usually given in kilovolt amperes reactive kvar and voltage in volts V Exist a confusion that is necessary to clarify the matter of the definition of these two quantities The reactive power varies with the voltage as shown in equation Oe Ue Ur x Or Where Oe is the capacitor output at Ue voltage Ue is the tension that normally apply to the battery voltage Ur is the rated voltage or nominal for which the battery has been manufactured and that allows you to work permanently in accordance with EN 60831 1 and 2 Or or nominal rated power resulting from applying rated voltage battery for which it was designed Examples If a capacitor bank of 100kvar 440V you applie 400V the net output will be only 82 kvar a 18 below of the output of a bank of 100kvar 400V For a battery rated voltage 440V delivers an output of 100kvar at 400V must have a power of 121kvar Expertos en energia reactiva y armonicos Experts in reactive energy and harmonics www cydesa com gi c Anotaciones Notes CYDESA Experts in reactive energ
48. 0 1000 1443 6x240 2 2500 2020 1 Seg n el REBT 2002 actualizado con UNE 20 460 5 523 2004 El modo B2 corresponde a cables tripolares bajo tubo E a cables multipolares sobre bandeja perforada y F a cables unipolares sobre bandeja perforada 2 En caso de varias ternas se supone una disposici n con alternancias RST TSR y en una sola capa 3 Dimensionado del cable e interruptor para 1 5 Icn 4 Rel s t rmicos a 1 4 Icn Fusible a 1 3 1 According to IEC 60364 5 523 and CENELEC HD 384 5 523 The type B2 corresponds to multicore cables in ducts E to multicore cables on perforated tray and F to single core cables on perforated tray 2 If there are several ternary groups we assume a layout with alternation RST TSR and in only one layer 3 Cable and circuit breaker size for 1 5 len 4 Thermal relays at 1 4 Icn Fuse at 1 3 Icn CYDESA Experts in reactive energy and harmonics 107 Manual T cnico_Tablas y formulario 230V Secciones de cable y calibre de las protecciones para baterias de condensadores a 230V 50 Hz e Para otras potencias o tensiones consultar 40 C Potencia Corriente Secci n del conductor de cobre seg n el modo de instalaci n para 40 C Interruptor Interruptor asignada de temperatura ambiente UNE 20460 5 523 2004 magneto seccionador a 230V Dimensionado para 1 5 Ic t rmico calibre regulaci n fusible B1 unipolar B2 tripolar C tripolar E tripolar
49. 0 605 720 1890x1160x445 264 EL 400P 500 11 20 14 534 00 1250 2 608 00 525 25 10x50 635 756 1890x1160x445 256 EL 400P 525 11 21 15 336 00 1250 2 608 00 550 11x50 666 792 1890x1160x445 268 EL 400P 550 11 11 15 797 00 1250 2 608 00 575 25 11x50 696 828 1890x1160x445 271 EL 400P 575 12 23 15 915 00 1250 2 608 00 600 12x50 726 864 1890x1160x445 261 EL 400P 600 12 12 16 301 00 1250 2 608 00 625 25 2x50 5x100 756 900 1890x1160x445 290 EL 400P 625 8 2b 16 740 00 1 650 5046x100 787 936 1890x1160x445 292 EL 400P 650 7 13 17 315 00 1 675 25 50 6x100 817 972 1890x1160x445 266 EL 400P 675 8 27 17 939 00 1 700 2x50 6x100 847 1008 1890x1160x445 299 EL 400P 700 8 14 18 266 00 1 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 e Suplemento por dispositivo comunicador Modbus Sotware 150 1 S lo es posible incorporar int en la serie EG Other extra prices e Residual current circuit breaker on page 65 e Modbus device Software pack 150 1 You can only add int in the EG series 56 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Baterias de Premium capacitor bank condensadores EG 400P Premium EG 400P Caracteristicas Technical data e Caracter sticas en pag 44 e Con regulador de la serie FPM p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente e Technical data on page 44 e With series FPM
50. 0 1 727 1 788 1 930 1 88 0 47 1 128 1 258 1 394 1 422 1 452 1 483 1 515 1 549 1 586 1 627 1 675 1 736 1 878 1 83 0 48 1 078 1 208 1 343 1 372 1 402 1 432 1 465 1 499 1 536 1 577 1 625 1 685 1 828 1 78 0 49 1 029 1 159 1 295 1 323 1 353 1 384 1 416 1 450 1 487 1 528 1 576 1 637 1 779 1 73 0 50 0 982 1 112 1 248 1 276 1 306 1 337 1 369 1 403 1 440 1 481 1 529 1 590 1 732 1 69 0 51 0 937 1 067 1 202 1 231 1 261 1 291 1 324 1 358 1395 1 436 1 484 1 544 1 687 1 64 0 52 0 893 1 023 1 158 1 187 1 217 1 247 1 280 1 314 1 351 1 392 1 440 1 500 1 643 1 60 0 53 0 850 0 980 1 116 1 144 1 174 1 205 1 237 1 271 1 308 1 349 1 397 1 458 1 600 1 56 0 54 0 809 0 939 1 074 1 103 1 133 1 163 1 196 1 230 1 267 1 308 1 356 1 416 1 559 152 0 55 0 768 0 899 1 034 1 063 1 092 1 123 1 156 1 190 1 227 1 268 1 315 1 376 1 518 1 48 0 56 0 729 0 860 0 995 1 024 1 053 1 084 1 116 1 151 1 188 1 229 1 276 1 337 1 479 1 44 0 57 0 691 0 822 0 957 0 986 1 015 1 046 1 079 1 113 1 150 1 191 1 238 1 299 1 441 1 40 0 58 0 655 0 785 0 920 0 949 0 979 1 009 1 042 1 076 1 113 1 154 1 201 1 262 1 405 1 37 0 59 0 618 0 749 0 884 0 913 0 942 0 973 1 006 1 040 1 077 1 118 1 165 1 226 1 368 1 33 0 60 0 583 0 714 0 849 0 878 0 907 0 938 0 970 1 005 1 042 1 083 1 130 1 191 1 333 1 30 0 61 0 549 0 679 0 815 0 843 0 873 0 904 0 936 0 970 1 007 1 048 1 096 WAS 1 299 1 27 0 62 0 515 0 646 0 781 0 810 0 839 0 870 0 903 0 937 0 974 1 015 1 062 1 123 1 265 1623 0 63 0 483 0 613 0 748 0 777 0 807 0 837 0 870 0 904 0
51. 0 113 651 00 4 hilos 20 851 00 22 189 00 32 085 00 34 997 00 85 111 00 93 171 00 103 548 00 Para la elecci n del filtro activo ver pag 36 37 y 88 91 For the election of the active filter see p 36 37 and 88 91 68 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Active filters Gama de filtros activo Active filtres range CYDESA Experts in reactive energy and harmonics 69 Manual t cnico Technical handbook Energ a reactiva Reactive energy Gu a t cnica para la compensaci n de energ a reactiva Technical guide for reactive power compensation Arm nicos Harmonics Filtros Activos Active Filters Condensadores de media tension Un gt 1000 V Medium voltage capacitors Un gt 1000 V Equipos para compensaci n de energ a reactiva en M T M V Equipments for power factor correction 72 78 84 88 92 96 Conocimiento Knowledge Para progresar el conocimiento debe transmitirse y compartirse por este motivo en CYDESA siempre nos hemos esforzado en facilitar a nuestros clientes los conocimientos y herramientas necesarias para aplicar con seguridad y garant a las soluciones para la correcci n del factor de potencia En este breve espacio confiamos en contribuir al logro de este prop sito To advance knowledge must be transmitted and shared for this reason in CYDESA we have always strived to provide our customers with the knowledge and tools necessary to implement safety and sec
52. 00 1250 2 608 00 600 12x50 726 1890x1160x445 261 EL 400 600 12 12 12 072 00 1250 2 608 00 625 25 2x50 5x100 756 1890x1160x445 290 EL 400 625 8 25 12 352 00 1 650 50 6x100 787 1890x1160x445 292 EL 400 650 7 13 12 521 00 1 675 25 50 6x100 817 1890x1160x445 266 EL 400 675 8 27 12 913 00 1 Other extra prices e Residual current circuit breaker on page 65 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 1 Solo es posible incorporar interruptor en la serie EG p g 50 1 To include a switch disconnecter is only possible in series EG page 50 48 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Potencia de 212 5 hasta 400 kvar Potencia de 425 hasta 700 kvar Output from 212 5 to 400 kvar Output from 425 to 700 kvar Instalaci n compensada por CYDESA Metro de Sevilla Facilities compensated by CYDESA Sevilla s subway CYDESA Experts in reactive energy and harmonics 49 Baterias de condensadores estandar EG 400V 50Hz Caracteristicas e Caracteristicas generales en pag 44 e Con regulador de la serie FPM ver p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Autotrafo de maniobra 400 230V e Acometida por la parte inferior e Protecci n diferencial opcional e Fijaci n sobre suelo Lista de Precios 2014_Equipos Standard capacitor bank EG 400V 50Hz
53. 0V bOHz Caracteristicas e Caracteristicas generales en pag 44 e Montaje mural hasta 62 5 kvar y mural o sobre suelo a partir de 67 5 kvar e Regulador FPM ver p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Acometida inferior e Protecci n diferencial opcional suplemento p g 65 1 Lista de Precios 2014_Equipos Standard capacitor bank EC 400V 50Hz Technical data e Technical data on page 44 e Wall mounted up to 62 5 kvar and wall or floor mounted from 67 5 kvar e FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Incoming at the bottom e Optional residual current protection extra price on page 65 1 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio Size Price kvar 400V kvar 440V mm kg A 7 5 2 5 5 9 500x400x200 20 EC 400 7 5 2 3 984 00 63 130 00 12 5 2 54 2x5 ils 500x400x200 22 EC 400 12 5 3 5 1 124 00 63 130 00 17 5 2 5 5 10 21 500x400x200 23 EC 400 17 5 3 7 1 181 00 63 130 00 25 5 2x10 30 500x400x200 24 EC 400 25 3 5 1 237 00 63 130 00 30 5 2x12 5 36 500x400x200 24 EC 400 30 3 5 1 294 00 63 130 00 35 5 10 20 42 700x500x250 32 EC 400 35 3 7 1 405 00 125 15
54. 1 230 V U3 3V V5 10V y V7 2V se calcular a W 102 2 2 EF 30 62 io 4 00 Habitualmente el factor de distorsi n no supera el 5 en instalaciones industriales Valores superiores deber an implicar medidas de protecci n especialmente en lo que concierne a la bater a de condensadores Para m s detalles consultar nuestro programa de c lculo CYDESA PFC La resonancia Constituye un fen meno muy conocido tanto en electricidad como en mec nica y no es otra cosa que una amplificaci n importante de una determinada magnitud En una instalaci n el ctrica en donde existe un transformador y una bater a de condensadores aparece una resonancia paralelo dada por en donde ST potencia del trafo kVA uk tensi n de cc del trafo O potencia de la bater a kvar hr arm nico en resonancia 100 S n Uk Q Para el ejemplo 1 anterior suponiendo uk 5 resultar a _ 100 400 _ dem TES T T 9 es decir el arm nico en resonancia est alejado del 5 y 7 arm nicos que son los m s importantes Por tanto no deber an esperarse problemas Para el ejemplo 2 suponiendo as mismo uk 5 resultar a h 100 400 om OY otek Y E T frecuencia demasiado pr xima al arm nico caracter stico de orden 7 Posiblemente en este caso ser a conveniente instalar un equipo con filtros Como regla general la frecuencia de resonancia debe de quedar lo suficientemente alejada de los arm nicos presentes en
55. 1 de junio de 2006 1 a 26 de junio de 2006 Pagina 1 de 13 HORMATIVA APLICADA FECHA DE RECEPCI N FECHA DE ENSAYOS El objeto de ensayo ha sido sometido a las pruebas requeridos por el solicitante aplicando los procedimientos especificados en la normativa antes indicoda ESTE DOCUMENTO CONSTA DE HP de p ginas 15 JE Pen ar bur ENS Jefa del Laboratorio de Elbciracea Io docena um egi ia pf id lum aig Barakaldo a 30 de junio de 2006 Mejore su red el ctrica Improve your electric network Los condensadores ESTAprop destacan por sus reducidas dimensiones y bajas p rdidas Dotados de un dispositivo interno de protecci n para evitar la rotura del contenedor en caso de perforaci n del diel ctrico Los condensadores ESTAprop son de larga duracion al alcanzar una esperanza de vida de 150 000 horas lo que supone 17 anos en servicio permanente 24 7 ESTAprop capacitors distinguished by its small size and low losses Equipped with an internal protection device to prevent breakage of the container in case of puncture the dielectric ESTAprop Capacitors are long lasting to achieve a life expectancy of 150 000 hours which is 17 years in continuous 24 7 1 CYD ES ong del BHorts 5 ST o Sant Vic ES Y ommum AF E mc l f 4 ESTA i prop e Un PhMKP 400 2 25 00 Hz O 4 8 Gal we ores c I Ui 192 G Lista de Pr
56. 20 ENF 400 250 6 10 11 530 00 630 1 179 00 275 25 5x50 309 1800x1200x400 335 ENF 400 275 6 11 11 810 00 630 1 179 00 300 6x50 337 1800x1200x400 350 ENF 400 300 6 6 13 390 00 630 1 179 00 e Para interruptor autom tico y diferencial ver p g 65 1 Ver nota a pie de p gina 32 e Residual current circuit breaker on request See page 65 1 See note at the bottom of page 32 CYDESA Experts in reactive energy and harmonics 61 Lista de Precios 2014 Equipos V ituros ne d filters Capacitor bank EGF with detuned filter circuits fr 189 Hz Bater as de condensadores EGF con filtros de recha ZO fr 189 Hz These equipments have L C filters tuned to 189Hz which is equivalent to a harmonic order of hr 3 78 and a reactance factor of p 7 Estos equipos incorporan filtros L C sintonizados a 189Hz lo que equivale a un orden de arm nico de hr 3 78 y un factor de reactancia p 7 The main duty of these filters is to com pensate the reactive energy but they also absorb harmonic currents mainly of 5th harmonic and therefore they reduce the harmonic voltages This reduction can be considered approximately of 2596 La funci n principal de estos filtros es la compensaci n de la energ a reactiva si bien tambi n absorben corrientes arm nicas principalmente del 5 arm nico y por tanto reducen las tensiones arm nicas Esta reducci n puede estimarse del orden del 25 Equipo serie EGF Equipment of the
57. 22 5 55 75 15 0 20 0 20 0 25 0 90 125 20 0 30 0 35 0 40 0 110 0 135 0 EEUU 400 100 0 125 0 150 0 175 0 EN O d 100 0 150 0 175 0 250 0 EN M Uc 125 0 175 0 200 0 300 0 Para potencias superiores considerar el 30 de la potencia en kW del motor O kvar 0 3 P kW Oc Potencia reactiva en kvar m xima del condensador para compensaci n sin riesgo de autoexitaci n El Cos obtenido es superior o igual a 0 95 La tabla ha sido confeccionada considerando los principales fabricantes de motores del mercado For higher power considering 3096 of the engine power in kW O kvar 0 3 P kW Oc Reactive power in kvar capacitor for maximum compensation without risk of self excitation The CosqQ obtained is greater than or equal to 0 95 The table has been prepared considering the major motor manufacturers in the market CYDESA Experts in reactive energy and harmonics 105 Manual T cnico_Tablas y formulario Tabla Ill Factor f tan 1 tan 2 Table Ill f Factor tan 1 tan 2 O kvar Potencia de Condensadores Ol kvar Capacitors Output P kVV PIKW potencia activa x f active power x f Existente Factor de potencia deseado coso Given Target power factor cosq Tang Cosy 0 80 0 85 0 90 0 91 0 92 0 93 0 94 0 95 0 96 0 97 0 98 0 99 1 00 1 98 0 45 1 235 1 365 1 500 1 529 1 159 1 589 1 622 1 656 1 693 1 734 1 781 1 842 1 985 1 93 0 46 1 180 1 311 1 446 1 475 1 504 17535 1 567 1 602 1 639 1 68
58. 3 0A y 3 1A 6 1 a 6 5 2 llano 3 valle 1a5 6 TR 0 TR 0 Improvement of voltage level By compensating an electrical network drop out voltages are reduced then available voltage is increased If compensation is automatic as usual and we maintain a good coso for any value of the charge then it will be possible to maintain a voltage with few variations due to drop out voltages Drop out voltages in networks are mainly produced on power transformers and in lesser extent on lines Due to compensation and to the higher transformer s reactance regarding to the lines this drop out reduction is perceptible on the transformers and imperceptible on the lines By way of example on a network supplied by a 250 kVA transformer it is produced a drop out voltage reduction approximately about 65 by passing from a 0 7 to 1 0 cos and about 22 by passing from 0 7 to 0 9 Technical handbook La compensacion de la energia reativa contribuye a la lucha contra el cambio clim tico Las p rdidas de la red el ctrica son de gran importancia por su elevado coste energ tico Se miden por los coeficientes de p rdidas que permiten traspasar la energ a suministrada a los consumidores en sus contadores a energ a suministrada en barras de central Como gran parte de estas p rdidas dependen del cuadrado del cos se comprende su importante reducci n al mejorar el F P Tabla resumida de los coeficientes de p rdidas en la red el ctrica espa ola en
59. 4 00 39 520x 395 435 x135 13 PhP 230 35 987 00 40 520x 395 435 x135 15 PhP 230 40 1 111 00 440V 50Hz 10 430x 183 224 x98 5 PhP 440 10 291 00 15 520x 195 236 x135 6 PhP 440 15 333 00 20 520x 195 236 x135 6 5 PhP 440 20 348 00 25 520x 195 236 x135 6 5 PhP 440 25 379 00 30 520x 195 236 x135 8 PhP 440 30 488 00 40 520x 260 300 x135 9 PhP 440 40 579 00 50 520x 260 300 x135 10 PhP 440 50 633 00 60 520x 260 300 x135 11 PhP 440 60 736 00 70 520x 395 435 x135 13 PhP 440 70 847 00 75 520x 395 435 x135 14 PhP 440 75 880 00 80 520x 395 435 x135 15 PhP 440 80 973 00 100 520x 395 435 x135 17 PhP 440 100 1 085 00 Leer m s en la p gina siguiente gt gt Read more on the next page gt gt 12 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Capacitors Prismatic capacitors Serie Estandar Standard Series Potencia Output kvar 10 20 25 30 40 50 60 75 100 Potencia Output kvar 20 25 30 40 50 60 75 100 30 50 60 80 100 Dimensiones Dimensions 430x 183 224 x98 520x 195 236 x135 520x 195 236 x135 520x 195 236 x135 520x 260 300 x135 520x 260 300 x135 520x 260 300 x135 520x 260 300 x135 520x 395 435 x135 Peso Weight H x A A 1 x B mm kg 525V 50Hz 5 6 5 8 9 10 11 ils 15 17 Tipo Type PhP 525 10 PhP 525 20 PhP 525 25 PhP 525 30 PhP 525 40 PhP 525 50 PhP 525 60 PhP 525 75 PhP 525 100 Serie Est ndar Standard Series Dimensiones Dimensions H x A
60. 4 29 244 00 1600 2 985 00 750 50 7x100 844 2200x1800x800 970 EGF 400 750 8 15 30 369 00 1600 2 985 00 800 2x50 7x100 900 2200x1800x800 1010 EGF 400 800 9 16 31 930 00 e Para interruptor autom tico y diferencial ver p g 65 1 Ver nota a pie de p gina 32 oscani Instalaci n compensada por CYDESA 1 Teatros del Canal Madrid 2 Institut Universitari Dexeus Barcelona e Residual current circuit breaker on request See page 65 1 See note at the bottom of page 32 i BNE y ii T W i 1 PT Facilities compensated by CYDESA 1 Teatros del Canal Madrid 2 Institut Universitari Dexeus Barcelona CYDESA Experts in reactive energy and harmonics Lista de Precios 2014 Equipos Capacitor bank EDTF EGTF at 400V 50Hz with static switches and detuned filtres circuits Bater as de condensadores EDTF EGTF con contactor est tico 400V 50Hz y filtros de rechazo fr 189 Hz tr 189 Hz Technical Data Caracteristicas e Technical data on page 44 e With series FPM controller see page 22 e Capacitors see page 8 e Static switches see page 26 e Autotrans for aux voltage 400 230V e Supply entry from the below e Optional residual current protection e Technical data for filter page 54 e Caracter sticas generales en p g 44 e Con regulador de la serie FPM ver p g 22 e Condensadores ver p g 8 e Contactores est ticos ver p g 26 e Autotrafo de maniobra 400 230V e Acom
61. 400P 150 4 6 4 767 00 400 592 00 175 25 3x50 212 252 1000x600x400 85 ED 400P 175 4 7 5 266 00 400 592 00 200 2x25 3x50 242 288 1000x600x400 86 ED 400P 200 5 8 5 904 00 630 607 00 Other extra prices e Residual current circuit breaker on page 65 e Modbus device Software pack 150 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 e Suplemento por dispositivo comunicador Modbus Sotware 150 CYDESA Experts in reactive energy and harmonics 55 Lista de Precios 2014_Equipos Bater as de condensadores Premium EL 400P Premium capacitor bank EL 400P Caracter sticas Technical data e Caracter sticas generales en p g 44 e Con regulador FPM ver p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Autotrafo de maniobra 400 230V e Acometida por la parte inferior e Protecci n diferencial opcional e Fijaci n sobre suelo Caracter sticas de la serie Premium en p gina 54 e Technical data on page 44 e With FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Autotrans for aux voltage 400 230V e Incoming at the bottom e Optional residual current protection e Floor mounted Technical data from the Premium equipmet on page 54 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Compos
62. 50kA 3 428 00 4 031 00 4 925 00 500 600 EG EGF EGT 1250A 50kA 3 695 00 4 672 00 5 550 00 25 ENF 250A 25kA 1 322 00 966 00 1 352 00 150 175 ENF 400A 25kA 1 353 00 1 698 00 2 166 00 200 300 ENF 630A 36kA 1 746 00 2 063 00 2 529 00 LE EZR ES SIN ES EZ IIS SN El armario cambia a 700x500x250 mm A Interruptor diferencial Residual circuit breaker Interruptor con transformador toroidal y rel diferencial Switch with transformer toroidal and residual current relay CYDESA Experts in reactive energy and harmonics 65 Filtros activos Active filters El desarrollo tecnol gico nos ha ofrecido a lo largo de la historia avances espectaculares en todas la areas de la actividad humana sin embargo no podemos obviar algunos de los inconvenientes que este desarrollo implica Un ejemplo de esta apreciable dualidad lo constituye por una parte el enorme desarrollo de la electr nica de potencia al incorporarse en la mayor parte de los equipos industriales de entre los cuales sobresalen los variadores de velocidad para motores de corriente alterna de sobra son conocidas las ventajas de los variadores ya nadie discute el ahorro de energ a y facil regulaci n que se obtiene con los mismos Por otra parte y a pesar de ello no podemos Ignorar sus efectos adversos en la red el ctrica como la distorsi n producida en las ondas de corriente y tensi n y que se manifiesta con la aparici n de arm nicos en instalacione
63. 60 125 1 973 00 63 3412424424 52 5 600x500x250 20 PROSEC 63 125 1 990 00 66 6 12 24 24 55 600x500x250 20 PROSEC 66 125 1 999 00 69 3 12 24 30 57 5 800x600x300 26 PROSEC 69 160 2 385 00 78 12412424430 65 800x600x300 26 PROSEC 78 160 2 422 00 87 3412424424424 125 800x600x300 28 PROSEC 87 160 2 634 00 90 15 15 30 30 75 800x600x300 28 PROSEC 90 160 2 589 00 92 5 5 12 5 25 25 25 76 4 800x600x300 28 PROSEC 92 250 2 721 00 96 12 24 30 30 80 800x600x300 28 PROSEC 96 250 2 693 00 108 3 15 30 30 30 90 800x600x300 30 PROSEC 108 250 2 940 00 112 5 6 15 30 30 30 93 800x600x300 30 PROSEC 112 250 2 946 00 114 15 15 24 30 30 95 800x600x300 32 PROSEC 114 250 2 971 00 120 15 15 30 30 30 100 800x600x300 32 PROSEC 120 250 3 014 00 CYDESA Experts in reactive energy and harmonics 41 Bateria de condensadores Prosec 440 V bOHz de 135 a 240 kvar Caracter sticas e Fijaci n sobre suelo e Con regulador de la serie Masing FPM e Condensadores ESTAprop e Contactores con resistencias previas para limitaci n de la corriente de conexi n Lista de Precios 2014 Equipos Capacitor Bank Prosec 440 V bOHz from 135 to 240 kvar Technical Data e Floor mounted e With Series controller Masing FPM e Capacitors ESTAprop e Contactors with resistors prior to current limiting connection e Switch disconnector e Autotransformer for aux voltage e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 e Interruptor tripolar de c
64. 7 00 42 5 5 12 5 25 51 700x500x250 34 EC 400 42 5 3 8 1 461 00 125 157 00 50 10 2x20 61 700x500x250 35 EC 400 50 3 5 1 573 00 125 157 00 62 5 12 5 2x25 76 700x500x250 37 EC 400 62 5 3 5 1 685 00 125 157 00 67 5 5 12 5 2x25 82 800x600x250 38 EC 400 67 5 4 13 1 910 00 160 176 00 75 2x12 5 2x25 91 800x600x250 38 EC 400 75 4 6 1 967 00 160 176 00 87 5 12 5 3x25 106 800x600x250 49 EC 400 87 5 4 7 2 584 00 250 261 00 92 5 5 12 5 3x25 112 800x600x250 49 EC 400 92 5 5 18 2 696 00 250 261 00 100 2x12 5 3x25 121 800x600x250 50 EC 400 100 5 8 2 752 00 250 261 00 Other extra prices Otros suplementos e Para interruptor autom tico y diferencial ver p g 63 1 e Por autotrafo de maniobra 400 230V hasta 62 5kvar 48 00 hasta 100kvar 56 00 1 En caso de solicitar el interruptor diferencial ste sustituye al interrup tor es decir no puede incluirse interruptor e interruptor diferencial en un mismo equipo El interruptor diferencial es de 300mA de sensibilidad tipo A protegido contra disparos intempestivos CYDESA Expertos en energ a reactiva y arm nicos e Residual current circuit breaker on page 63 1 e Control autotransformer 400 230V up to 62 5kvar 48 00 up to 100kvar 56 00 1 If the residual current circuit breaker is requested this one replaces the switch disconnector that is to say the switch disconnector and the residual current circuit breaker cannot be included in the same eq
65. 700x500x250 32 EC 400 40 CF 1 402 00 EC 400R 40 CF 1 446 00 50 125 700x500x250 34 EC 400 50 CF 1 446 00 EC 400R 50 CF 1 539 00 60 25 700x500x250 36 EC 400 60 CF 1 685 00 EC 400R 60 CF 1 742 00 70 63 100 800x600x250 37 EC 400 70 CF 1 920 00 EC 400R 70 CF 2 029 00 75 63 125 800x600x250 37 EC 400 75 CF 1 941 00 EC 400R 75 CF 2 075 00 80 100 100 800x600x250 48 EC 400 80 CF 2 160 00 EC 400R 80 CF 2 231 00 100 125 125 800x600x250 48 EC 400 100 CF 2 251 00 EC 400R 100 CF 2 416 00 120 125 125 800x600x250 50 EC 400 120 CF 2 575 00 EC 400R 120 CF 2 753 00 P A1 H A2 150 A A partir de 70kvar From 7Okvar CYDESA Experts in reactive energy and harmonics 18 Condensadores con reactancias y fusibles para filtros de rechazo frz189Hz Incorporan condensadores con reactancias conectadas en serie formando un filtro L C sintonizado a 189Hz para frecuencia de red de 50Hz Estos filtros est n indicados para la compensaci n fija de motores o transformadores reactiva propia del trafo en instalaciones con presencia de arm nicos Evitan la sobrecarga de los condensadores y eliminan la posibilidad de resonancia en la red Al mismo tiempo reducen las corrientes y tensiones arm nicas en la red en un 2596 aproximadamente Caracter sticas e Condensadores caracter sticas p gina 8 e Reactancia para formar un filtro de rechazo sintonizado a fr 189Hz e Fusibles generales APR incluidos e Interruptor general como suplemento
66. 71 1 NEMA publicaci n CP1 ANSI IEEE norma 18 BS 1650 y 2897 CSA C22 2 N 190 Normas Hasta 24kV en monof sico y 12 kV en trif sico Tensiones nominales P rdidas 0 1W kvar durante las primeras horas de servicio 0 05W kvar a partir de 500h Las p rdidas m ximas incluyendo resistencias de descarga fusibles internos y conexiones pueden alcanzar 0 15W kvar 5 15 para condensadores individuales 5 10 para bater as de hasta 3Mvar 0 10 para bater as de 3Mvar hasta 30Mvar 096 5 para bater as de m s de 30Mvar Film de polipropileno Tolerancia de capacidad Diel ctrico Impregnante Aceite no PCB Sobretensiones x Un Duraci n admisibles 1 1 12h cada 24h 1 15 30min cada 24h 1 2 5min T3 1min Sobrecargas de 1 3 IN de forma permanente corriente Condiciones de instalaci n Altura No superior a 1000m Montaje Vertical con aisladores en la parte superior u horizontal con caja apoyada en la cara m s estrecha Superior a 100 000 horas de servicio Esperanza de vida CYDESA Expertos en energ a reactiva y arm nicos The medium voltage capacitors are manufactured with coils composed by aluminium layers between polypropylene layers These coils are introduced in a steel sheet container filled with non PCB oil The single phase capacitors are manufactured up to approximately 1000kvar for indoor use or for outdoor use and up to a rated voltage of 24kV The three phas
67. A1 x B mm 520x 195 236 x135 520x 195 236 x135 520x 195 236 x135 520x 260 300 x135 520x 260 300 x135 520x 260 300 x135 520x 260 300 x135 520x 395 435 x135 520x 260 300 x135 520x 260 300 x135 520x 260 300 x135 520x 395 435 x135 520x 395 435 x135 Dimensiones Terminales Peso Weight 7 8 9 10 11 12 15 17 kg 690V 50Hz 1050V 50Hz 10 11 12 15 17 1 Terminales L1 L2 y L3 M8 hasta up to TU H e 1 i i e l B o Gp y M10 hasta up to 1 Terminals L1 L2 and L3 400 20 400R 20 230 10 440 20 525 25 690 25 400 30 400R 30 230 15 440 30 525 30 690 30 Tipo Type PhP PhP PhP PhP PhP PhP PhP PhP 690 20 690 25 690 30 690 40 690 50 690 60 690 75 690 100 PhP 1050 30 PhP 1050 50 PhP 1050 60 PhP 1050 80 PhP 1050 100 Precio Price 291 00 341 00 398 00 475 00 580 00 612 00 784 00 856 00 1 059 00 Precio Price 390 00 401 00 519 00 608 00 684 00 794 00 931 00 1 160 00 550 00 680 00 975 00 1 106 00 1 242 00 Dimensions Terminals M12 hasta up to 400 100 400R 80 230 40 440 100 525 100 690 100 1050 100 CYDESA Experts in reactive energy and harmonics 2 Terminal de tierra 2 Earthing terminal M6 hasta up to M10 hasta up to 400 10 400R 10 440 10 400 100 400R 80 230 40 440 100 525 100 690 100 1050 100 14 Condensadores prismaticos con seccionador m s fusibles Los condensa
68. ACI N NUCLEAR ASCO VANDELLOS II BP OIL REFINER A DE CASTELL N CANAL DE ISABEL Il CEPSA CLH EDISON GRUPO EDP ELCOGAS ENAGAS ENDESA EON ESPANA EPAL GAS NATURAL UNI N FENOSA HC ENERG A IBERDROLA NATURGAS ENERG A PEGOP RED EL CTRICA DE ESPA A REN REPS REPSOL CYDESA has a Quality Management System based on the standard ISO 9001 as well as other certificates of our products granted by important laboratories which allows our customers to trust in CYDESA s products and services The PhMKP ESTAprop capacitors are certified by the Underwriter s Laboratories Inc UL This certificate consists of a destructive test that proves the security and the effectiveness of the overpressure tear off fuse With this purpose UL carries out several inspections in the manufacturer s factory in order to guarantee a permanent product quality The capacitor banks have the test certificate in relation to EN 61921 2004 of the Labein laboratory labeiny tecnalia ima 14 401087 id iraia LABORATORIO DE EQUIPOS EL CTRICOS Si hr UNIDAD DE EMERG A LIT A A Fer Informe de ensayos Ic seitens mean aaa N B124 06 8 EE 01 J eas binrin am Ensayos de tipo I d OBJETO DE ENSAYO Equipo paro correcci n del factor de potencia DESIGHACI N EC 400 100 5 B TH E SOLICITANTE ETDESA Pol Ind Sant Antoni Parcela 2 Mave A 08620 ST VICENG DELS HORTS Barcelona UNE EN 61921 2004 UNE EN 60439 1 2001441 2005
69. It s the most usual way to compensate installations where there are normally several loads Calculus of the capacitors power in an installation in project From the project we can get the following information Total installed power PT kW Simultaneity factor Fs The average cos Cosq If we want to achieve a cos the required capacitors power will be F F QzPr 49g tan 9i tan po Pr 4955 f f value taken from the table Ill on page 106 Example 1 Installation where it is known that the set of loads power is of 230 kW and only the half of them are on service An average cos of 0 8 is considered and we want to reach a cosq of 0 98 We fix the value f 0 547 from the table therefore zi WED e S Q 230 455 0 547 63 kvar Example 2 We try to compensate an installation fed by a trafo of 1000 kVA when the installed power as well as the cos and the simultaneity factor are not exactly known As usual values we can consider Cos 0 8 Cosq 0 95 Transformer u 6 and 80 of full load The capacitor output will be OF for the transformer 50kvar table on page 100 O for load 1000 x 0 8 x 0 8 x tanq1 tan 2 1000 x 0 64 x 0 421 269 kvar CYDESA Experts in reactive energy and harmonics 83 84 Tanto en las industrias como en los edificios de oficinas cada vez es mas frecuente encontrarse con receptores que deforman la onda de las corrientes que absorben corrientes que a
70. Lista de precios Manual t cnico 2014 Price list Technical manual CYDESA Lista de precios y manual t cnico 2014 Quedan prohibidos dentro de los l mites establecidos en la ley y bajo los apercibimientos legalmente previstos la reproducci n total o parcial de esta obra para cualquier medio o procedimiento ya sea electr nico o mec nico el tratamiento inform tico el alquiler o cualquier otra forma de cesi n de la obra sin la autorizaci n previa y por escrito de los titulares de CYDESA Impreso en Espa a Printed in Spain Indice Table of contents Lista de precios Price list Manual t cnico Technical manual Condensadores Capacitors Componentes Components Baterias de condensadores Capacitor banks Filtros activos Active filters Manual tecnico Technical handbook Tablas y formulario Tables and formularies 20 34 66 70 102 Calidad Quality RePro empowered by Achilles Registrado 311328 V lido hasta Julio 2013 CYDESA posee un Sistema de Gestion de la calidad basado en la norma ISO 9001 asi como certificaciones de producto por laboratorios acreditados los cuales permiten a nuestros clientes confiar en los productos y servicios de CYDESA Los condensadores ESTAprop PhMKP poseen el certificado de Underwriter s Laboratories Inc UL El certificado incluye un ensayo destructivo que permite comprobar la seguridad y eficacia del desconectador de sobrepresi n P
71. P 525 20 00 3 228 00 CAP 84 6 00 25 84 x 265 1 9 PhMKP 525 25 00 3 270 00 CAP 84 6 00 690V 50Hz Conexi n por terminal faston o brida Protecci n IPOO IP20 con tapa de protecci n resistencias de descargas sueltas 1 Fast on or clamp terminal connection Protection IPOO or IP20 with protective cover discharge resistors included 1 10 64 x 265 11 PhMKP 690 10 00 2 131 00 CAP 64 5 00 15 84 x 265 1 9 PhMKP 690 15 00 3 212 00 CAP 84 6 00 20 84 x 340 2 4 PhMKP 690 20 00 3 260 00 CAP 84 6 00 25 84 x 340 2 9 PhMKP 690 25 00 3 282 00 CAP 84 6 00 50 m o e T 84 IPOO IPOO IP54 IP20 IP20 1 Discharge at 50 V in 1 min except with protection IP54 75 V 3 min 2 Fast on terminal connection 3 Clamp terminal connection CYDESA Experts in reactive energy and harmonics 11 Lista de Precios 2014 Condensadores Condensadores prism ticos Caracter sticas p g 8 Resistencias de descarga incorporadas 75 V en 3 min Protecci n IP43 Acabado RAL 7032 2 series est ndar y reforzada La serie est ndar soporta 415V de forma permanente y una sobretensi n temporal hasta 460V La potencia est referida a 400V Technical data on page 8 Discharge resistors assembled 75 V in 3 min Protection IP43 Painting colour RAL 7032 2 series standard and higher rated The standard series can operate permanently at 415V and temporary up to 460V Power is referred to 400V The higher
72. P43 Al producirse un defecto o perforaci n interna se generan gases que presionando sobre la tapa provocan la rotura de las conexiones NOTA debe dejarse un espacio libre de 25 mm como m nimo por encima de los terminales En servicio Op condition al liea i Terminales ES Terminals M LI Conexiones por la parte exterlor de la bobina Connection stipes outside the winding elements Dispositivo de protecci n por sobre presi n interna desconectador de sobrepresi n Life expectancy gt 150 000 operating hours Connection current Up to 300 x ln it is recommended to reduce to 100 x ly with the application of contactors with previous resistors Electrical protecion Overpressure tear off fuse Mechanical protection Cylindrical IPOO IP20 with Terminal cover or IP54 Prismatic IP43 As soon as an internal breakdown occurs gases are created These gases press the cover and cause the tear off of the internal fuses NOTE a free space of at least 25 mm over the terminals should be left Desconexi n de todas las fases AlFPhase Disconnection Gas producido por la perforaci n Protective device for internal overpressure overpressure tear off fuse CYDESA Experts in reactive energy and harmonics 9 Lista de Precios 2014 Condensadores Condensadores cil ndricos Caracter sticas p gina 8 Resistencias de descarga para 50V 1 min IPOO 6 75V 3 min IP54 Potenci
73. _ 100 S 400 100 25 S CON 110 o ER 400 100 2 27 596 Esto nos situar a entre la l nea continua y a puntos por tanto podr a instalarse una bater a reforzada premium ver p gina 50 Ejemplo 2 Sea el caso del ejemplo anterior pero con 150 kvar de potencia de condensadores Qc _ 150 8 400 S CON Sr 100 37 5 27 5 En este caso nos situamos por encima de la linea punteada y por tanto seria necesario un equipo con filtros de rechazo Cabe observar que la figura 3 1 facilita tan solo un criterio orientativo para la elecci n del equipo m s indicado Para un c lculo m s preciso recomendamos consultar a nuestro departamento t cnico CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Consultar e on request Fig 3 1 El gr fico permite la elecci n de la bater a de con densadores adecuada en instalaciones con cargas perturbadoras variables de velocidad c a This figure allows the choice of the appropriate capacitor bank facilities disturbing loads AC variable oe 4 speed 10 caw 4 Sp O Capacitor bank output kvar D Transformer power kVA S Power converters kVA CON Below the continuous line of the above figure is possible to install a conventional bank with capacitors at the mains voltage Between this line and the dotted one to install Premium capacitors banks that support a possible overload is recommended Over the dotted line equipments w
74. a Dimensiones Peso Tipo Precio Cubrebornes Precio Output Dimensions Weight Type Price Terminal cover Price kvar mm e x h kg Protection IP20 400V 50Hz Conexi n por terminal faston Protecci n IPOO IP20 con cubrebornes resistencias de descarga sueltas 1 Fast on terminal connection Protection IPOO or IP20 with terminal cover discharge resistors included 1 25 64 x 190 0 8 PhMKP 400 2 5 00 81 00 CAP 64 5 00 5 64 x 190 0 8 PhMKP 400 5 00 100 00 CAP 64 5 00 75 64 x 190 0 8 PhMKP 400 7 5 00 125 00 CAP 64 5 00 10 64 x 265 1 1 PhMKP 400 10 00 133 00 CAP 64 5 00 125 64 x 265 rl PhMKP 400 12 5 00 158 00 CAP 64 5 00 Conexi n por brida Protecci n IPOO IP20 con cubrebornes resistencias de descarga incorporadas 1 Clamp connection Protection IPOO or IP20 with terminal cover discharge resistors assembled 1 15 84 x 190 1 4 PhMKP 400 15 00 203 00 CAP 84 6 00 20 84 x 265 1 9 PhMKP 400 20 00 240 00 CAP 84 6 00 25 84 x 265 T9 PhMKP 400 25 00 282 00 CAP 84 6 00 Con cable de conexi n de 500 mm de longitud Protecci n IP54 resistencias de descarga incorporadas 1 With connection cable of 500 mm in length Protection IP54 discharge resistors assembled 1 25 66 x 225 0 9 PhMKP 400 2 5 54 104 00 5 66 x 225 0 9 PhMKP 400 5 54 125 00 75 66 x 225 0 9 PhMKP 400 7 5 54 144 00 10 66 x 300 1 2 PhMKP 400 10 54 162 00 125 66 x 300 12 PhMKP 400 12 5 54 178 00 15 86 x 225 1 5 PhMKP 400 15 54 234 00 20 86 x 300 2 0 PhMKP 400 20 54
75. a reactancia sera de 430V por lo que la tensi n asignada del condensador deber ser superior Por otra parte debe considerarse la potencia reactiva inductiva absorbida por la reactancia por lo que la potencia entregada por el condensador a la red Nc ser inferior a la potencia de ste En la tabla siguiente se indican la potencia Nc junto a la potencia asignada del condensador referida a 440V Lista de Precios 2014 Componentes Capacitors for detuned filter circuits fr 189 Hz They are capacitors to connect in series with the previous reactances For mains voltage at 400V the terminals voltage of the capacitor due to the reactance will be 430V and as a consequence the capacitor rated voltage should be higher Besides the inductive reactive power absorbed by the reactance should be considered For this reason the power given by the capacitor to the network Nc will be lower than the capacitor output On the following table you can see the power Nc together with the capacitor rated output referred to 440V Terminales de conexi n Connection terminals Terminales de tierra Earth terminals M10 25 kvar M10 M12 50 kvar 400V 50Hz Potencia util Potencia nominal Dimensiones Peso Tipo Precio Reactive output Rated output Dimensions Weight Type Price Nc 1 On 1 Hxo oHxAxB kvar 400V kvar 440V mm kg Ejecuci n cil ndrica IPOO conexi n por brida con resistencias de descarga incorporadas caracter sticas en pa
76. aci n Propietario Modbus RTO Communication Owner Modbus RTO Sana OS 8A 250 VAC AC 1 Contacts Temperaturas admisibles Maximum temperatures ARMAS Proteccion IP41 Protection N de escalones Dimensiones Programa de Peso Tipo Precio Number of steps Frontal x Fondo conexi n Weight Type Price Dimensions Connection Front x depth program mm 1 kg 6 1 1 1 0 720 FPM p6 568 00 149x149 x60 T2 12 1 2 2 0 770 FPMp12 681 00 ll 1 Cualquier otra combinaci n siempre que la relaci n entre la 1 Any other combination provided that the relation between the power potencia del escal n m s peque o y la de cualquier otro sea un valor of the smallest step and another one is an integer value between 1 and entero comprendido entre 1 y 16 16 CYDESA Experts in reactive energy and harmonics 25 Cil E2 es Lista de Precios 2014_Componentes Contactores Contactores para maniobra de condensadores Los contactores K3 K est n especialmente indicados para la maniobra de condensadores Por medio de contactos previos que insertan las resistencias de limitaci n desconect ndolas de nuevo al cerrar los contactos principales La punta de corriente de conexi n del condensador queda pr cticamente eliminada La reducci n del transitorio de conexi n evita la soldadura de contactos as como las posibles perturbaciones en la red Con este tipo de contactor resultan innecesarias la resistencias de descarga r pida po
77. acion es necesaria para evitar la autoexcitacion del motor fen meno que se produce especialmente en motores que puedan ser arrastrados por la carga al desconectarlos de la red y siempre que el condensador se conecte a bornes del motor Si no se dan estas circunstancias el condensador puede llegar a igualar la potencia reactiva a plena carga del motor Ejemplo Motor que acciona una m quina de gran inercia riesgo elevado de autoexcitaci n potencia 75 kW a 1500 r p m Se tomar el valor indicado en la tabla 25 kvar para la potencia del condensador Si el condensador se conectara a bornes del motor pero a trav s de un contactor no ser a necesaria la limitaci n citada del 90 de la reactiva de vac o Ejemplo Motor de 350 kW para accionamiento de una bomba con cose a plena carga de 0 88 y rendimiento del 97 se desea compensar a cos 0 97 Se calcula la potencia del condensador de la forma habitual por la f rmula tradicional ver tabla Ill p gina 106 Cr pf En este caso y seg n la mencionada tabla f 0 289 luego _ 990 0 97 0 289 104 kvar En motores con arranque estrella triangulo compensar conectando el condensador al lado del contactor de linea o con un contactor independiente Compensacion en caso de arranque estrella triangulo Compensation with a star delta starting CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico The capacitors output of the table corresponds to the
78. ada 5X240 2000 575 1443 F Cables unipolares sobre 6X240 600 1506 bandejas perforadas 6X240 625 1569 6X240 108 CYDESA Expertos en energ a reactiva y arm nicos Technical handbook Tables and formularies Formulario Potencias Activa P UIx 10 kW corriente continua P UIxcos x 10 kW c a monof sica P N3xUlcos y x 10 kW caa trif sica Aparente S 13xUlx 10 kvar c a trif sica Reactiva QzSxsin Q P tan Q kvar Potencias de m quinas y receptores trif sicos Transformadores S V3xUIx 10 KVA Condensadores Q N3xUIx 10 kvar Motor P N3xUIxcos Q xn x 103 kw n rendimiento P rdida en cables Ap AP P 22xVF xR P c a monof sica Ap AP P Z Sx x R P caa trif sica RL puede calcularse por la expresi n RL p xL S con Pay 17 24 ohm x mm km Pa 28 26 ohm x mm km Conexi n de condensadores En paralelo En serie O qx o 1 H HH Es UU Us 1 C 1 C 1 C 1 C U U U U En tri ngulo o estrella Suponiendo las potencias iguales Q Q C 23C Suponiendo las capacidades iguales C C 0 30 Formularies Powers Active P UIx10 kW DC P UIxcos x 10 kW 1 phase AC P 3xUlcos x 10 kW 3 phase AC Apparent S V3 x U Ix 10 kvar 3 phase AC Reactive QzSxsin P tan kvar Power of loads and three phase machines Transformers S V3xUIx 10 KVA Capacitors Q N3xUIx 10 kvar Motor P N3xUIxcos Q xn x 103 kw r efficienc
79. al n EC 7 5 30 FPM Inferior Below 500x400x200 Muro Wall 35 62 5 Masing 700x500x250 u 67 5 100 FPM Inferior Below 800 x600x250 Muro Wall Masing 150 de pies i 150 of feet ED 112 5 200 FPM Inferior Below 1000 x600x400 Suelo Floor Masing 150 de pies 150 of feet EL 212 5 400 FPM 12 Inferior Below 1890x580x445 Suelo Floor i 425 700 Masing 1890x1160x445 Suelo Floor v EG 400 450 FPM 12 Inferior Below 2000x600x600 Suelo Floor 475 1000 Masing 2000x1200x600 Suelo Floor CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Bater as de condensadores estandar standard capacitor bank EB 400V EB 400V 50HZz con interruptor auto 50Hz with circuit breaker m tico incorporado Some consumers have low reactive energy consumption enough to be punished by the electric tariffs but not enough to have a good payback if they installed a standard capacitor bank The EB equipments have the goal to give an economical solution to this type of consumers with different outputs to each need EB equipments have one capacitor controlled by a reactive relay that works as a P F controller When the customer consumes reactive energy the RINT Masing relay calculates the cos and at a set value it switches on the capacitor The RINT Masing relay allows to set e The switch off cos e The switch on cos q e Switch on off delay time e Automatic and manual function P
80. already mentioned in several cases it is necessary to connect in series the appropriate reactors together with the capacitors which forms a harmonic filter Equipo o bater a con filtros para arm nicos Equipment or bank with harmonic filters Technical handbook Harmonics En las instalaciones con presencia de armonicos lo que se is compensated it is usually expected that neither harmonics pretende generalmente es que al compensar la energia reactiva amplification nor resonance problems take place In these cases no se produzca ni amplificaci n de arm nicos ni por supuesto equipments with detuned or low tuned filters are installed L C problemas de resonancia En estos casos se instalan equipos tuning frequency at 189Hz for mains frequency at 50Hz and con filtros de rechazo o baja sintonizaci n frecuencia de 227Hz for 60Hz sintonizaci n L C de 189 Hz para frecuencia de red de 50Hz y 227Hz para 60Hz Thatis equal to a res onance ratio Lo que equivale a un factor de resonancia p qr 7 p 12 7 pos y un factor de reactancia Filtros de rechazo 1389Hz Doed Mies TOS Consultar s Or request Premium Premium Est ndar 400V Standard 400V 0 3 10 15 20 has 3D Su 40 45 ell Fig 3 1 El gr fico permite la elecci n de la bater a de condensadores adecuada en instalaciones con cargas perturbadoras variables de velocidad c a This figure allows the choice of the appropria
81. ara ello UL realiza inspecciones peri dicas en la planta del fabricante para garantizar la calidad permanente del producto Las bater as disponen del certificado de ensayo seg n EN 61921 2004 del laboratorio Labein BUREAU VERITAS Certitication Certificaci n Certification Concedida a Amarded lo CONSTRUCCIONES Y DISTRIBUCIONES EL CTRICAS S A CYDESA POL IND SANT ANTONI PARCELA 2 NAVE A eA SANT VICENG DELS HORTS BARCELONA Bureau Veritas certifica que el Sistema de Gesti n ha sido auditado y encontrado conforme con los requisitos de la norma Burnes Vertes Cani hal he Managed Sy mem Fuld ben audited and fund bn Be in co with fus repente nf srt NORMA sanoan ISO 9001 2008 El Sistema de Gesti n se aplica a FABRICACI N DE CONDENSADORES Y EQUIPOS PARA CORRECCI N DE FACTOR POTENCIA MANUFACTURING PROCESS CAPACITORS AND POWER FACTOR CORRECTION EQUIPMENTS N mero del certificado E5048394 1 Decir Cares Qacerii Marge Borsa Ventas Dairin 54 erat rome Dirge accom dare a Cova ee ite AA p EBan ae Eacfaciaed da certificado mare afi perd al d ied p ret palet y a de Md ered de bir in hl rl c p TE Mor orsa eee Coe borsa eciam Darrf ame dh Ei bree orion iacula tinm Ne I ENAC CYDESA cuenta con el certificado Repro condici n para suministrar a las siguientes empresas CYDESA has the Repro certify provide condition for the following companies GRUPO AGBAR ASOCI
82. arm nicas Esta reducci n 1 See note at the bottom of page 32 60 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Capacitor banks with detuned filters Bater as de condensadores ENF con filtros de rechazo frz189Hz Estos equipos incorporan filtros L C sintonizados a 189Hz lo que equivale a un orden de arm nico de hr 3 78 y un factor de reactancia p 7 La funci n principal de estos filtros es la compensaci n de la energ a reactiva si bien tambi n absorben corrientes arm nicas principalmente del 5 arm nico y por tanto reducen las tensiones arm nicas Esta reducci n puede estimarse del orden del 25 Capacitor bank with detuned filter circuits fr 189HZ These equipments have L C filters tuned to 189Hz which is equivalent to a harmonic order of hr 3 78 and a reactor factor of p 7 The main duty of these filters is to compensate the reactive energy but they also absorb harmonic currents mainly of 5th harmonic and therefore they reduce the harmonic voltages This reduction can be considered approximately of 25 Caracteristicas Tension de red Potencias Tensiones armonicas admisibles Sobrecorriente admisible a 50 Hz P rdidas m x totales aprox Regulador Autotrafo de maniobra Acometida Ventilaci n Temperatura ambiente 400V 50 Hz Est ndar hasta 300 kvar U3 0 5 Un U5 U7 5 Un Technical Data Mains voltage Outputs Allowed harmonic voltages Allowed over
83. ce protection for assemblies with double star See page 92 From 25 C to 40 C average 24h with a maximum value of 50 C Corresponding to the level Il according to CEI 815 Protection Allowed ambient temperature Pollution degree Protection The protection of the high voltage capacitors deserves a special attention because it allows minimizing the explosion risk The single phase units can include internal fuses that together with unbalance protections for assemblies with double star represent a high safety protection for internal breakdowns This protection should be completed with others of short circuit current overload overvoltage and undervoltage For the three phase units the internal fuses are not operative and an unbalance protection is not possible For this reason the external fuses are essential due to their fast operation compared to other devices such as automatic circuit breakers As an extra protection for coil punctures which produces gases and therefore an internal overpressure is important to add the device D that includes a pressure sensor with a changeover contact that allows indicating and acting on a breaking device contactor or circuit breaker Moreover the corresponding over and undervoltage protections should be included Protecci n de un condensador trif sico por sensor de sobrepresi n Three phase capacitor protection by means of an overpressure sensor Risk of explosion
84. ci n autom tica Compensaci n de receptores individuales en los que no se recomienda una conexi n directa a bornes por ejemplo motores Technical data see page 8 e Losses lower than 1 2 W kvar e Protection IP30 e Supply entry from the below e Painting colour RAL 7035 Caracteristicas generales ver pag 8 e P rdidas inferiores a 1 2 W kvar e Protecci n IP30 e Acometida inferior e Acabado RAL 7035 2 series estandar y reforzada 2 series standard and higher rated The standard series can operate permanently at 415V and temporary up to 460V The power is always referred to 400V La serie estandar soporta 415V de forma permanente y temporalmente hasta 460V La potencia siempre esta referida a 400V The higher rated series can operate permanently at 440V and La serie reforzada soporta 440V de forma permanente y temporary up to 490V The power is always referred to 400V hasta 490V temporalmente La potencia siempre esta referida a 400V Serie Reforzada Higher rated Series Serie Estandar Standard Series Potencia Fusibles Dimensiones Peso Tipo Precio Tipo Precio Output Fuses Dimensions Weight Type Price Type Price HxAxB kvar A mm kg 400V 50Hz 20 40 500x400x200 23 EC 400 20 CF 893 00 EC 400R 20 CF 948 00 25 63 500x400x200 23 EC 400 25 CF 915 00 EC 400R 25 CF 997 00 30 63 500x400x200 30 EC 400 30 CF 1 164 00 EC 400R 30 CF 1 271 00 35 80 700x500x250 31 EC 400 35 CF 1 371 00 EC 400R 35 CF 1 406 00 40 100
85. cing the most loaded phase unnecessary heating The FA can be programmed to correct these imbalances Fliker attenuation The fliker is a phenomenon causing oscillations of low frequency voltage that are especially annoying for in the lighting effect and consequently in the human eye As the reactive current is compensated by the AF if produce corresponding reduction in the oscillations of the voltage drops and therefore the fliker But to not alter the active current oscillations compensation is obviously limited CYDESA Experts in reactive energy and harmonics 89 Dimensionamiento de un filtro activo para el filtrado de arm nicos Para determinar la capacidad del filtro activo procederemos como sigue Calcular la corriente fundamental en el supuesto de que como es habitual el dato sea la corriente total eficaz incluyendo arm nicos bz TE 14 THDI La corriente arm nica a compensar se calcular por I 1 THDi THDi Donde THDi es la tasa de distorsi n arm nica a alcanzar Ejemplo de dimensionamiento En una red industrial con un elevado equilibrio en las 3 fases se han medido e Corriente de l nea 330 A e Factor de distorsi n de corriente THDi 4096 Se desea reducir la distorsi n al 1096 Calculamos gt fo e RADA La corriente arm nica a compensar ser I5 I THDi THDi 284 48 0 4 0 1 85 344 Elegiriamos el ECOSine Active FN 3420 100 480 3 de 100A de capacidad de
86. citors see page 8 e Contactores con resistencias previas e Contactors with previous resistors to para limitaci n de la corriente damp the switch on current PL de conexi n e Incoming at the bottom a e Acometida por la parte inferior e Circuit breaker protection e Protecci n por magnetot rmico e Possibility to purchase the current e Posibilidad de adquirir transformador transformer appropriate to the de intensidad adecuado al equipo y a equipment and the installation la instalaci n 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento por trafo Output Composition Dimensions Weight Type Price de intensidad TI 1 HxAxB Extra price for current transformer Tl 1 kvar 400V kvar 440V mm kg 5 6 25 365x260x160 3 EB 400 5 615 00 64 00 1 7 5 9 365x260x160 3 EB 400 7 5 647 00 64 00 1 10 12 9 365x260x160 3 EB 400 10 679 00 64 00 1 125 15 365x260x160 3 EB 400 12 5 709 00 64 00 1 15 18 365x260x160 4 EB 400 15 740 00 64 00 2 20 24 365x260x160 4 EB 400 20 801 00 64 00 2 25 30 365x260x160 B EB 400 25 863 00 64 00 2 1 Para instalar en la acometida general de la instalaci n 1 To install at tje point of common compling 2 Relaci n 50 5 2 Ratio 50 5 3 Relaci n 100 5 3 Ratio 100 5 CYDESA Experts in reactive energy and harmonics 45 46 150 A Kk la A partir de 67 5kvar From 67 5kvar Bater as de condensadores estandar EC 40
87. controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current de conexi n e Autotransf for aux voltage 400 230V E e Autotrafo de maniobra 400 230V e Incoming at the bottom B 3 LE e Acometida inferior e Floor mounted e Fijaci n sobre suelo Caracter sticas de la serie Premium en p gina 54 Technical data from the Premium equipmet on page 54 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio kvar kvar kvar Size Price 400V 440V 480V mm kg A 400 8x50 484 576 2000x600x600 230 EG 400P 400 8 8 10 646 00 1000 1 959 00 400 2x25 7x50 484 576 2000x600x600 230 EG 400P 400 9 16 11 720 00 1000 1 959 00 425 25 8X50 514 612 2000x600x600 242 EG 400P 425 9 17 12 365 00 1 1 425 25 8x50 514 612 2000x1200x600 320 EG 400P 425 9 17 A 13 773 00 1000 2 402 00 450 9x50 545 648 2000x600x600 244 EG 400P 450 9 9 12 842 00 1 1 450 9x50 545 648 2000x1200x600 323 EG 400P 450 9 9 A 14 252 00 1000 2 402 00 475 25 9x50 575 684 2000x1200x600 328 EG 400P 475 10 19 15 377 00 1000 2 402 00 500 10x50 605 720 2000x1200x600 331 EG 400P 500 10 10 15 778 00 1250 2 708 00 500 2x25 9x50 605 720 2000x1200x600 331 EG 400P 500 11 20 15 898 00 1250 2 708 00 525 25 10x50 635 756 2000x1200x600 344 EG 400P 525 11 21 16
88. cteristicas CEI 60871 1 EN 60871 1 para condensadores CEI 60298 EN 60298 para los equipos Principales normas Tensiones asignadas Hasta 12kV 50 60 Hz Hasta 800 kvar por escal n con condensadores trif sicos Sin limitaci n con condensadores monof sicas en doble estrella Potencias Los individuales indicados en CEI 298 EN 60298 Ensayos Interior IP31 25 C a 35 C media en 24h Con un valor m ximo de 40 C Ejecuci n Temperatura ambiente admisible Altitud del lugar de instalaci n No superior a 1 000m Equipo EG con un escal n fijo Para compensaci n fija de receptores La ejecuci n b sica comprende un condensador trif sico con sensor de presi n p g 89 inductancia de choque y fusibles de A P R Opcionalmente pueden incorporar interruptor de corte de carga seccionador de p a t y testigos luminosos de presencia de tensi n Equipo EG con contactor Esta soluci n elimina el riesgo de autoexcitaci n si al desconectar el motor se desconecta simultaneamente el condensador en el supuesto de estar ste conectado a bornes de motor y maniobrado por un contacto auxiliar del contactor de motor Tambi n permite la maniobra autom tica con regulador de energia reactiva La ejecuci n b sica comprende un condensador trif sico con sensor de presi n con contacto que act a sobre el contactor contactor de vac o inductancias de choque y fusibles de A P R Opcionalmente pueden incorporar s
89. ctiva y arm nicos All the capacitor banks Basic and Prosec have the IT included CYDESA presents a new range of capacitor banks that meet a two purposes 1_Complying regulations regarding protections against short circuits and overloads indirect contact 2_To facilitate installation of capacitor banks without changing the installation Capacitor banksd Prosec and Basic 9 incorporate a switch with mechanical interlock protection fuses and their closets are double insulated The envelope used in our batteries and Basic Prosec the external control of the switch and the cover meet with protection against indirect contact as class II contemplates the ITC BT 24 Therefore it is not putting application ground or differential protection which helps simplify the installation and avoid nuisance tripping in the event of a RCD Automatic capacitor bank Prosec Basic are built according to 61921 2003 IEC EN 61921 All capacitor banks are made in Spain and all its components are manufactured in the European Union The capacitors have a rated voltage of 440V support 490V eight hours every 24 hours and have a life expectancy 150 000 hours more than 17 years if they worked 24 hours a day Price List 2014 Equipment i HLL lt lt Bateria de condensadores Basic 440V BOHZ de un solo escal n Caracter sticas e Fijaci n mural e Condensadores ESTAprop e Contactores con resistencias previas para limitac
90. current at 5 Irms 50 Hz 6 W kvar Max Losses approx FPM Controller type 400 230V Autotrans for aux voltage Inferior Incoming Forzada Cooling 15 C max 40 C max 35 Ambient temperature de media en 24h Equipo serie ENF Equipment of the ENF series 400V 50 Hz Standard up to 300 kvar U3 0 5 UN U5 U7 5 Un 5 Irms 6 W kvar FPM 400 230V At the bottom Forced 15 C max 40 C max 35 average 24h Altitud 1000m Sobre nivel del mar Altitude 1000 m Above sea level Proteccion IP 30 Protection IP 30 Acabado RAL 7035 Painting colour RAL 7035 400V 50Hz Potencia util Potencia Dimensiones Peso Tipo Precio Suplemento Reactive output nominal Dimensions Weight Type Price int de corte Ne 1 Composici n Composition Rated output On 1 HxAxB Extra price for switch Disc Calibre Precio Size Price kvar 400V kvar 440V mm kg A 125 1x25 2x50 141 1800x1000x400 205 ENF 400 125 3 5 7 874 00 250 752 00 150 2x25 2x50 169 1800x1000x400 230 ENF 400 150 4 6 8 436 00 400 915 00 175 25 3x50 197 1800x1000x400 250 ENF 400 175 4 7 8 999 00 400 915 00 200 4x50 225 1800x1000x400 265 ENF 400 200 4 4 9 843 00 630 957 00 200 2x25 3x50 225 1800x1000x400 270 ENF 400 200 5 8 10 123 00 630 957 00 225 25 4x50 253 1800x1200x400 305 ENF 400 225 5 9 10 686 00 630 1 179 00 250 5x50 281 1800x1200x400 315 ENF 400 250 5 5 11 248 00 630 1 179 00 250 2x25 4x50 281 1800x1200x400 3
91. d steps and fixed in stanby to compensate the reactive power of the power transformer of the network thus avoiding the separate installation of a capacitor Records hours of operation to facilitate preventive maintenance tasks For accurate compensation and comprehensive control of the network three phase regulators Masing FPMp Premium are themarket smarter solution for power factor regulation It also incorporated a complete network analyzer 22 Lista de Precios 2014 Componentes Reguladores de energ a reactiva Power factor controller Reguladores de energ a reactiva Masing serie FPM Los reguladores de energia reactiva Masing serie FPM disponen de un potente microprocesador que incluye numerosas funciones y prestaciones Mediciones e Cos instant neo e Tensi n instant nea e Corriente instant nea e Temperatura del equipo e Registro de los valores medidos m ximos de tensi n corriente THD y temperatura Alarmas e Subcompensaci n y sobrecompensaci n e Corriente m nima y m xima en el secundario del T I e Sobrecarga de los condensadores e Exceso de temperatura Protecciones e Contra sobrecarga de corriente en condensadores e Contra sobretensi n e Contra exceso de temperatura en el equipo e Contra exceso de arm nicos Otras prestaciones e Opci n de set up autom tico e Puerto serie TTL RS232 para comunicaci n con PC para set up y visualizaci n de medidas e Funci n de bloqueo de
92. de tensi n por detecci n de sobretensi n y por detecci n de exceso de Protecciones Masing static contactors M400 with GL fuses MASING Contactores estaticos Masing MasingO static contactors Tipo Potencia nominal Precio Type Output Price kvar 400V M400 25 25 1 719 00 M400 50 50 1 899 00 M400 100 100 2 1 197 00 1 Ventilaci n natural Natural air cooling 2 Ventilaci n forzada Forced air cooling Technical data EN 50178 EN 60831 1 Main standards and 2 and EN 60439 By GL fuses do not protect the thyristors by voltage mutch detection by overvoltage detector and by overtemperature detector Protections Use Indoor IPOO Maximum ambient 50 C temperature temperatura Ejecucion IPOO Temperatura ambiente 504C m xima P rdidas 2 3 W kvar Montaje sobre placa T Nominal funcionamiento 400 V AC Tensi n auxiliar 230 V AC Dimensiones mm Peso kg 159x368x185 25 50 kvar 224x378x185 100 kvar 4 5 para 25 y 50kvar y 6 para 100kvar Losses Mounted Rated voltage Auxiliary voltage Dimensions mm Weight kg 2 3 W kvar on plate 400V AC 230 V AC 159x368x185 25 50 kvar 224x378x185 100 kvar 4 5 para 25 and 50kvar and 6 para 100kvar CYDESA Experts in reactive energy and harmonics 27 Ventajas Proteccion por deteccion de huecos de tension Protecci n que aporta un plus de seguridad que permite interrumpir el funcionamiento en caso d
93. djustable Masing series FPM power factor controller Features Rango Ajuste por defecto Range Adjustment by default Programable Tensi n de alimentaci n 415V F F 15 10 230V F F o F N 15 10 415 Supply Voltage 50 60 Hz Consumo Comsume 5 6 VA 5A les ue Pg L mites Limits 0 125 5 5 A 5 uc LAE Consumo Consume 0 6 W Factor de potencia 0 85 ind 0 95 cap 1 Power Factor Sensibilidad Tiempo de respuesta Sensitivity Response Time Asus op Tiempo de reconexi n Restart time TARS 9d Escal n fijo Programable Step fixed Programmable Condos 8A 250V CA AC1 Contacts Temperaturas admisibles 10 50 C Maximum temperatures Proteccion IP41 Protection N de escalones Dimensiones Programa de Peso Tipo Precio Number of steps Frontal x Fondo conexi n Weight Type Price Dimensions Connection Front x depth program mm 1 kg 6 CEs 0 74 FPM6 286 00 149x149 x60 1 1 2 12 1 2 2 0 77 FPM12 343 00 1 2 3 1 Cualquier otra combinaci n siempre que la relaci n entre la potencia del escal n m s peque o y la de cualquier otro sea un valor entero comprendido entre 1 y 16 1 Any other combination provided that the relation between the power of the smallest step and another one is an integer value between 1 and 16 CYDESA Experts in reactive energy and harmonics 23 Nuevo Regulador trif sico Masing Premium Lista de Precios 2014 Componentes New Masing Premium 3 phase controller Los
94. dmisible C 50 50 50 50 50 50 50 Allowed ambient temperature Calibre max de fusible 2 A 63 80 100 160 160 200 250 Max fuse size 2 Seccion del cable de potencia Power cable cross section Rigido mm 0 75 6 1 5 25 1 5 25 4 50 4 50 4 50 10 120 Solid Flexible mm 1 4 25 16 25 16 10 35 10 35 10 35 25 95 Flexible Flexible con puntera mm 0 75 4 1 5 16 1 5 16 6 35 6 35 6 35 10 95 Flexible with cable end Contactos auxiliares 1 NA Auxiliary contacts Contactos auxiliares adicionales 1 3 3 4 3 4 3 4 3 4 3 4 5 4 Additional auxiliary contacts 1 Corriente t rmica m xima Ith 130 A 2 Para coordinaci n tipo 1 CEI 1 Highest thermical current Ith 130 A 2 For coordination type 1 CEI 947 4 1 Supone riesgo de soldadura de contactos sin peligro para las 947 4 1 Risk of contact welding without any risk for people 3 NA personas 3 NA HN10 6 NC HNO1 4 2 HB11 en los laterales y 1 HN HN 10 or NC HNO1 4 2 HB11 on the sides and 1 HN or 1 HA on the 1 HA en la parte superior top 26 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Capacitors Contactors Contactor Estatico Masing serie M400 para la maniobra de condensadores con fusible GL incorporados ioc Caracteristicas EN 50178 EN 60831 1 y 2 Principales normas y EN 60439 Protecci n mediante fusibles tipo GL no protegen a los tiristores por detecci n de hueco
95. dores PhP SF incorporan un seccionador con fusibles con capacidad de corte en carga Resultan la soluci n id nea para compensaci n de receptores individuales Se recomienda un accionamiento conexi n o desconexi n r pida pero sin esfuerzos excesivamente bruscos Caracter sticas generales p g 8 Protecci n IP40 PhP IP30 EC Acabado RAL 7032 PhP RAL 7035 EC Caracteristicas del seccionador e Intensidad nominal 160 A e Fusible tipo NHOO Icc 120 kA e N de maniobras gt 200 2 series est ndar y reforzada La serie est ndar soporta 415V de forma permanente y una sobretensi n temporal hasta 460V La potencia est referida a 400V La serie reforzada soporta 440V de forma permanente y hasta 490V temporalmente La potencia siempre esta referida a 400V Serie Estandar Standard Series Lista de Precios 2014 Condensadores Prismatic capacitors with fuse switch disconnector The PhP SF capacitors have a fuse switch disconnector with load breaking capacity They represent the perfect solution to compensate single loads A fast system of drive connection or disconnection without too abrupt efforts is recommended Technical data page 8 Protection IP40 PhP IP30 EC Painting colour RAL 7032 PhP RAL 7035 EC Switch characteristics e Rated current 160A e Type fuse NHOO Icc 120 kA e Number of switching operations gt 200 2 series standard and higher rated The standard serie
96. e its sizing and installation Lista de Precios 2014 Filtros activos Resumen de caracter sticas t cnicas ECOsine Active para redes de 400V 50 Hz FN 3420 3 hilos 30 480 3 b0 480 3 100 480 3 120 480 3 200 480 3 250 480 3 300 480 3 FN 3430 4 hilos 30 400 4 60 400 4 100 400 4 120 400 4 200 400 4 250 400 4 300 400 4 Corriente de 3 hilos 30A 50A 100A 120A 200A 250A 300A Compensa ci n 4 hilos F N 30 90A 60 180A 100 300A 120 360A 200 600A 250 750A 300 750A Frecuencia de conmutaci n 16 kHz Refrigeraci n Ventilaci n forzada T ambiente 40 C 30 C 40 C 30 C 40 C Interface Modbus RTU RS485 Modbus TCP IP Ethernet oe 3 hilos lt 900W lt 1300W lt 2200W lt 2500W lt 5000W lt 6000W lt 7500W P rdidas W 4 hilos lt 950W lt 1800W lt 3000W lt 3000W lt 5500W lt 6300W lt 8500W Ruido dBA 3 hilos 65dBA 65dBA 68dBA 68dBA 70dBA 70dBA 70dBA 1m 4 hilos 63dBA 63dBA 69dBA 69dBA 70dBA 70dBA 70dBA Dimensiones 3 hilos 360x590x290 360x590x290 468x970x412 468x970x412 800x2000x600 mm AxH xF 4 hilos 415x840x300 415x840x300 468x1460x412 468x1460x412 800x2000x600 Peso Kg 3 hilos 47kg 47kg 105kg 105kg 415kg 4 hilos 70kg 70kg 145kg 145kg 495kg Proteccion IP 20 Opcional IP54 IP 54 MEmpone 300 microsegundos respuesta Precio Te 3 hilos 20 602 00 21 251 00 31 787 00 34 276 00 92 652 00 97 413 0
97. e capacitors are manufactured up to 800 kvar and up to a rated voltage of 12kV Standards EN 60871 1 NEMA publication CP1 ANSI IEEE standard 18 BS 1650 and 2897 CSA C22 2 Num 190 Up to 24kV for one phase and 12kV for three phase Rated voltages 0 1W kvar during the first operating hours 0 05W kvar from 500h on The maximum losses including discharge resistors internal fuses and connexions can reach 0 15W Losses kvar Capacitance 5 15 for individual tolerance capacitors 5 10 for capacitor banks up to 3Mvar 0 10 for capacitors banks from 3Mvar up to 30Mvar 0 5 for capacitors banks from 30Mvar Dielectric Polypropylene film Impregnant Non PCB oil Allowed x UN Duration overvoltages 171 12h each 24h 1 15 30min each 24h 1 2 5min 1 3 1min Current overloads 1 3 IN permanently Installation conditions Altitude Not higher than 1000m Mounting Vertical with insulators on the top or horizontal with the case leaned on the narrowest side Life expectancy Over 100 000 operating hours Technical handbook Protecciones Ver pagina 92 De 25 C a 40 C media en 24h con un valor maximo de 50 C Temperatura ambiente admisible Grado de polucion Correspondiente al nivel II seg n CEI 815 Proteccion La protecci n de los condensadores de media tensi n merece una especial atenci n ya que sta permite minimizar el riesgo de explosi n En unidades monof sicas generalmente p
98. e perturbaciones en la red El equipo no reanuda el funcionamiento hasta pasado un tiempo de seguridad para la descarga del condensador Sistema de ventilaci n natural hasta 50 kvar La ausencia de ventilaci n forzada permite aumentar la esperanza de vida del contactor y reduce las p rdidas producidas por la ventilaci n Dise o El equipo se ha dise ado adapt ndolo a un montaje en placa con entrada de alimentaci n por la parte inferior y salida por la parte superior Advertencia No deben conectarse escalones convencionales con contactores electromagn ticos en la proximidad de la bater a con contactores est ticos Transformadores de corriente de n cleo partido Lista de Precios 2014 Componentes Advantages Notch voltage protection This protection is very helpful in case of a voltage failure The switch does not work again until some security time goes by to discharge the capacitor Natural cooling system up to 50 kvar The lack of forced cooling system allows to increase the switch life expectancy and reduces the losses generated by the forced cooling system Design The switch has been designed to be mounted on a plate with a suply entry by below and to be connected from the up side Warning Do not switch capacitors with thyristor swichting contactors if you have capacitor banks that are swichted by regular contactors oplit core current transformers 28 Tipo Dimensiones Apertura Potencia Preci
99. e su potencia nominal 630 0 95 6 222 mm Q 100 100 05 B30 15 4 kvar Sin embargo si este servicio no es permanente o el trafo puede ser cargado en un inmediato futuro hasta el 80 o 100 es preferible considerar la situaci n futura as aplicando la misma expresi n para el 100 de su potencia nominal la potencia 630 0 95 6 Q 400 105 80 43 8 kvar Conviene compensar el transformador con un escal n fijo OF escal n fijo para la compensaci n de la reactiva propia del transformador conectado antes del TI que alimenta al regulador de la bater a autom tica El regulador Masing FPM permite evitar la instalaci n de un condensador independiente mediante la opci n stand by OA bater a autom tica para compensar la carga del transformador receptores CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico On the assumption that the transformer usually works with a different power or for not normalized transformers the calculus of the capacitor output will have to be carried out by applying the following expression _ Swiio Ux S Y Q too 106 8 9 When SN transformer rated power kVA lo unload current in Uk impedance in S real service power in kVA Example Power transformer of 630 kVA with lo 0 95 Ux 6 which works at a rate of 50 of its rated power 630 0 95 6 2 Qz 400 100 0 5 630215 kvar However if this is not a continuous service
100. eccionador de p at y testigos luminosos de presencia de tensi n Equipos de compensaci n autom tica La ejecuci n b sica comprende condensadores inductancias de choque fusibles de A P R contactores de vac o y regulador para maniobrar autom ticamente los escalones en funci n de la demanda de reactiva en la red y el cos de consigna Opcionalmente pueden incorporar interruptor de corte en carga seccionador de p a t y testigos luminosos de presencia de tensi n Equipos con filtros de arm nicos En todas las ejecuciones pueden incorporarse filtros de arm nicos de rechazo a una frecuencia de sintonizaci n de 189Hz o bien filtros de absorci n sintonizados a frecuencias pr ximas a los arm nicos a absorber CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Technical data EN 60871 1 for capacitors EN 60298 for the equipments Main standards Up to 12kV 50 60 Hz Up to 800 kvar per step with three phase capacitors Without limit for single phase capacitors with double star The individual tests mentioned in the EN 60298 stand Use Indoor IP31 25 C to 35 C average 24h With a maximum value of 40 C Not higher than 1 000m Rated voltages Powers Tests Allowed ambient temperature Altitude of the installation place Equipment EG with a fix step For the fix compensation of the loads The basic equipment consists of a three phase capacitor with a pressure sensor page
101. ecios 2014 Condensadores Condensadores de baja tension ESTAprop Caracteristicas Normas Diel ctrico Impregnante Tensiones Nominales Ejecuciones P rdidas Tolerancia de capacidad Sobretensiones UN tensi n nominal del condensador Sobrecarga de corriente IN2 corriente nominal del condensador Ensayo de tensi n Entre terminales Entre terminal y caja Temperatura ambiente Tubular IPOO Tubular IP54 y Prism tica Condiciones de instalaci n Humedad Altitud Ventilaci n Posici n EN 60831 1 y 2 Film de polipropileno metalizado no PCB 230 V 400 V 440 V 525 V 690 V y 1050V 50 y 60 Hz Tubular IPOO hasta 25 kvar 400 V 30 kvar 440 V Tubular IP54 hasta 25 kvar 400V Prism tica IP43 hasta 100 kvar 400 V lt 0 25 W kvar para la ejecuci n tubular lt 0 5 W kvar para ejecuci n prism tica incluyendo las p rdidas en los cables 5 medida a 20 C de temperatura ambiente Un 10 hasta 8h al d a Un 15 hasta 30 min por d a Un 20 hasta 5 min Un 30 hasta 1 min IN 30 2 15 Un AC 2 seg 4800 VAC 2 seg 25 D m x 55 C media 24h 45 C 25 C m x 50 C media 24h 40 C m x 9596 m x 2000m Natural Vertical preferentemente 8 CYDESA Expertos en energ a reactiva y arm nicos Standards Dielectric Impregnant Rated voltages Types Losses Tolerance on capacitance O
102. ector e Trafo de intensidad incluido 2 CT Included 2 7 5 80 230 PROSEC PROSEC En los casos en que se persigue la 43 e Regulador FPM max 6 escalones maxima facilidad y comodidad de FPM Regulator 6 steps max instalacion e Interruptor de corte de carga incorporado When an easy installation is a priority With switch disconnector e Trafo de intensidad incluido 2 CT Included 2 In sheet steel cabinet 5 25 400 ESTANDAR STANDARD EB Instalaciones de consumo reducido 44 45 e Un solo escal n con rel de reactiva peque as industrias o comercios Only one step with reactive relay Installations with low consumption e Magnetot rmico incorporado small industries and shops With circuit breaker e Trafo de intensidad opcional Optional CT 7 5 1000 400 ESTANDAR STANDARD Instalaciones en general 46 50 e Regulador FPM m x 6 o 12 escalones In general FPM Regulator 6 or 12 steps m x eInterruptor de corte de carga opcional Optional switch disconnector 7 2 200 230 ESTANDAR STANDARD Instalaciones en general 230V 52 e Regulador FPM m x 6 o 12 escalones In general 230V FPM Regulator 6 or 12 steps m x e nterruptor de corte de carga opcional Optional switch disconnector Contin a en la siguiente p gina Continued on next page 36 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Guide tor Capacitor banks selection Rango de Tension potencias Output range kvar Voltage 1 V
103. eran las establecidas por las normas EN 60831 1 y CEI 61921 en particular en lo que hace referencia a e Tensi n de servicio e Temperatura ambiente e Tensiones arm nicas Es habitual que la tensi n que deban soportar los equipos O bater as de condensadores por estar conectadas en la mayor a de los casos a la misma salida del transformador sea superior a la asignada al equipo Por esta raz n y por posibles problemas de temperatura y o arm nicos puede ser necesario sobredimensionar no s lo los condensadores sino tambien el resto de componentes motivo por el que hemos creado la serie de equipos Premium Aseguran por tanto una larga duraci n en condiciones severas de servicio Los equipos Premium tienen su potencia referida a 400V soportan permanentemente 440V y de forma temporal 490V M xima fiabilidad en la compensaci n de la energ a reactiva mediante baliza que act a cuando el Cosq es inferior a 0 95 y la comunicaci n Modbus Mayor esperanza de vida mediante el sobredimensionamiento de los condensadores que soportan temporalmente 490V En los contactores y cables de potencia se utiliza un calibre superior al asignado nominal Lista de Precios 2014_Equipos The operating conditions of the capacitors equipments usually overcome the ones established by the standards EN 60831 1 and CEl 61921 specially referring to e Operating voltage e Ambient temperature e Harmonic voltages It is usual
104. erference resulting in the injection of a Harmonic spectrum the usual technique is to make the most significant with filters tuned to their respective frequencies thereby reducing harmonic distortion to acceptable values However passive filters have several drawbacks Incorporating inevitably capacitors provide capacitive reactive power to the grid in case of no power consumption receivers reactive as with variable frequency drives for induction motors is a drawback While it is feasible automatic regulation steps to accommodate different power compensation required harmonics the control strategy is complicated because it must avoid overloading some steps over others Cause resonances in the network that can while away the characteristic harmonics can amplify other harmonics unforeseen Its absorption capacity of harmonic currents can easily see provinentes surpassed by other parts of the network dangerously overloading the filter Its effectiveness depends on the impedance of the network subject to unforeseen changes it The variation of characteristics due to aging of the components results in the alteration of the tuning frequency and therefore there is the danger of overloading or destruction of the filter Some of the problems outlined above with appropriate designs solutions allow for example passive filters ECOsine Shaffner that cancels harmonic frequency drives without risk of overcharging The active filter
105. etida por la parte inferior e Protecci n diferencial opcional e Caracter sticas de los filtros p g 54 Equipo serie EGTF Equipment of the EGTF series 64 400V 50Hz Potencia util Potencia Dimensiones Peso Tipo Precio Suplemento Reactive output nominal Dimensions Weight Type Price int de corte Nc 1 Rated output HxAxB Extra price for Composici n Composition On 1 switch Disc Calibre Precio Size Price kvar 400V kvar 440V mm kg A 100 2x25 1x50 112 1300x600x660 203 EDTF 400 100 3 4 13 498 00 250 538 00 125 25 2x50 141 2200x600x800 218 EGTF 400 125 3 5 14 060 00 250 538 00 150 3x50 169 2200x600x800 243 EGTF 400 150 3 3 14 622 00 400 701 00 175 25 3x50 197 2200x600x800 333 EGTF 400 175 4 7 15 185 00 400 701 00 200 2x25 3x50 225 2200x1200x800 352 EGTF 400 200 5 8 15 747 00 630 743 00 225 25 4x50 253 2200x1200x800 373 EGTF 400 225 5 9 16 310 00 630 743 00 250 2x25 4x50 281 2200x1200x800 392 EGTF 400 250 6 10 17 997 00 630 1 179 00 275 25 5x50 309 2200x1200x800 414 EGTF 400 275 6 11 18 559 00 630 1 179 00 300 6x50 397 2200x1200x800 428 EGTF 400 300 6 6 19 121 00 630 1 179 00 325 25 2x50 2x100 366 2200x1200x800 592 EGTF 400 325 5 13 19 425 00 800 1 584 00 350 50 3x100 394 2200x1200x800 606 EGTF 400 350 4 7 19 684 00 800 1 584 00 375 25 50 3x100 422 2200x1200x800 610 EGTF 400 375 5 15 20 246 00 800 1 584 00 400 2x50 3x100 450 2200x1200x800 625 EGTF 400 400 5 8 21 371 00 1000 2 347 00 425 25
106. ference IN In the event that the desired capacitor bank with circuit breaker to calculate your PVP the supplement contained in this page breaker protection and add at the end of the reference lA In the event that the capacitor bank with leakage protection is desired to calculate your PVP should add the supplement contained in this page and add differential protection at the end of the reference DIF In the event that the desired capacitor bank with leakage protection circuit breaker and to calculate its PVP should add the supplement contained in this page and circuit breaker protection and add differential end of the reference lA DIF Interruptor Interruptor Interruptor diferencial autom tico aut dif C breaker Aut C breaker o Tipo Calibre Size A diff C breaker aut diff kvar 400V Type Icu kA 400V 7 5 30 EG 63A 25kA 369 00 702 00 35 50 EG 125A 36kA 336 00 658 00 62 5 75 EC 160A 36kA 387 00 707 00 87 5 100 EG 250A 25kA 846 00 1 149 00 25 50 ECF 125A 36kA 358 00 660 00 112525 ED 250A 25kA 1 265 00 895 00 1 352 00 150 175 ED 400A 25kA 1 542 00 1 648 00 2 067 00 200 ED 630A 36kA 1 714 00 2 028 00 2 431 00 50 75 EDF 160A 50kA 1 291 00 501 00 815 00 212 5 300 EL 630A 36kA 1 945 00 2 028 00 2 635 00 325 375 EL 800A 65kA 2 518 00 2 685 00 3 631 00 400 475 EL 1000A 85kA 3 336 00 3 937 00 4 557 00 300 375 EGF EGT 800A 65kA 2 62 00 2 905 00 3 867 00 400 475 EG EGF EGT 1000A
107. ferior e Protecci n diferencial opcional e Fijaci n sobre suelo 400V 50Hz Dimensiones Peso Tipo Dimensions Weight Type HxAxB mm kg 1300x600x660 237 EDT 400 100 3 4 1300x600x660 238 EDT 400 125 3 5 1300x600x660 248 EDT 400 150 3 3 2100x600x600 317 EGT 400 175 4 7 2100x600x600 237 EGT 400 200 5 8 2100x600x600 325 EGT 400 225 5 9 2100x600x600 337 EGT 400 250 6 10 2100x600x600 341 EGT 400 275 6 11 2100x600x600 347 EGT 400 300 6 6 2200x1200x600 339 EGT 400 325 5 13 2200x1200x600 341 EGT 400 350 4 7 2200x1200x600 358 EGT 400 375 5 15 2200x1200x600 362 EGT 400 400 5 8 2200x1200x600 370 EGT 400 425 6 17 2200x1200x600 369 EGT 400 450 5 9 2200x1200x600 383 EGT 400 475 6 19 2200x1200x600 386 EGT 400 500 6 10 2200x1200x600 394 EGT 400 525 7 21 2200x1200x600 393 EGT 400 550 6 11 2200x1200x600 399 EGT 400 575 7 23 2200x1200x600 403 EGT 400 600 6 6 2200x1200x600 406 EGT 400 600 7 12 2200x1200x600 409 EGT 400 625 8 25 2200x1200x600 429 EGT 400 650 7 13 2200x1200x600 441 EGT 400 675 8 27 2200x1200x600 448 EGT 400 700 8 14 standard capacitor bank EDT EGT equipment 400V b0Hz with static contactors Technical data e Technical data on page 44 e With series Masing FPM controller see page 22 e Capacitors see page 8 e Static contactors see page 26 e Autotrans for aux voltage 400 230V e Incoming at the bottom e Optional residual current protection e Floor mounted Precio Suplemento Price interruptor de corte e
108. for the voltage applied to the capacitor is deducted Price List 2014 Equipment Suplemento por protecci n diferencial e interruptor autom tico para todos los tipos de bater as En el caso de que la bater a de condensadores se desee con interruptor de corte en carga para calcular su PVP se deber sumar el suplemento que consta en las diferentes p ginas de los equipos y anadir al final de la referencia IN En el caso de que la bater a de condensadores se desee con interruptor autom tico para calcular su PVP se deber sumar el suplemento que consta en esta p gina por protecci n por interruptor autom tico y anadir al final de la referencia IA En el caso de que la bater a de condensadores se desee con protecci n diferencial para calcular su PVP se deber sumar el suplemento que consta en esta p gina por protecci n diferencial y anadir al final de la referencia DIF En el caso de que la bater a de condensadores se desee con interruptor autom tico y protecci n diferencial para calcular su PVP se deber sumar el suplemento que consta en esta p gina por protecci n por interruptor autom tico y diferencial y anadir al final de la referencia IA DIF oupplement for differential protection and circuit breaker for all types of bat teries In the event that the desired capacitor bank with load break switch to calculate your PVP should add the supplement contained in the pages and add equipment at the end of the re
109. g 8 IPOO cylindrical type with clamp connection and discharge resistors included technical data on page 8 1205 14 190x84 1 4 PhMKP 440 14 00 162 00 25 28 1 265x84 1 9 PhMKP 440 28 1 00 292 00 Ejecuci n prism tica IP 43 con resistencias de descarga incorporadas caracter sticas en p g 8 IP43 prismatic type use with discharge resistors assembled technical data on page 8 25 28 1 520x195x135 6 5 PhP 440 28 1 392 00 50 56 2 520x260x135 10 PhP 440 56 2 666 00 1 La potencia util de compensaci n Nc es la realmente entregada a la red e igual a la del condensador una vez deducida la potencia reactiva de la reactancia y la correcci n por la tensi n realmente aplicada al condensador CYDESA Expertos en energ a reactiva y arm nicos 1 The reactive output Nc is the reactive power supplied to the network and is equivalent to the capacitor output when the reactor reactive power and the correction for the voltage applied to the capacitor is deducted Price List 2014 Capacitors im f Wiis p SE A Any Wh M n Hip WAT TR A X N ll Hi ii ii y J i i F E Ta Ra EL E Ma ixi E 4 d s 3 E b T n F z zd mns f E IERI eo Lm Lm la F or med a T ij ti kif TES EM EN RM Al i Er L rt UL Instalaci n compensada por CYDESA Porta Fira L Hospitalet de Ll Instalaci n compensada por CYDESA Torre Iberdrola Bilbao Facilities compensated by CYDESA Porta Fira L Hospitale
110. ght Inductance Type Price asociado HxAxB Reactive output H Alto High Nominales Maximas of the assembled A Ancho Width Rated Maximum capacitor B Profundo Depth Nc 1 kvar 400V mm kg W 2 W 2 mH 12 5 160x180x110 11 65 80 3 067 R7P 400 12 5 300 00 25 205x225x135 18 90 140 1 535 R7P 400 25 468 00 50 235x296x167 33 135 200 0 766 R7P 400 50 599 00 100 325x296x177 48 250 340 0 384 R7P 400 100 986 00 1 La potencia til de compensaci n Nc es la realmente entregada a la red e igual a la del condensador una vez deducida la potencia reactiva de la reactancia y la correcci n por la tensi n realmente aplicada al condensador 2 Las p rdidas nominales corresponden a la corriente nominal sin arm nicos y las m ximas incluyen las debidas a la sobrecarga admitida a 50 Hz m s la de los arm nicos 1 The reactive output Nc is the reactive power supplied to the network and is equivalent to the capacitor output when the reactor reactive power and the correction for the voltage applied to the capacitor is deducted 2 The rated losses correspond to the rated current without harmonics and the maximum losses include the allowed overload at 50 Hz and the harmonics CYDESA Experts in reactive energy and harmonics 31 32 Condensadores para filtros de rechazo de armonicos fr 189 Hz Se trata de condensadores para conectar en serie con las reactancias anteriores Para tension de red de 400V la tension en bornes del condensador debido a l
111. i n de la corriente de conexi n e Rel de reactiva para maniobra del contactor e Sistema de corte visible mediante interruptor magnetot rmico de 16 a 40A seg n potencia e Montado en ARMARIO de poli ster RAL 7035 Protecci n mec nica IP30 440V 50Hz Potencia un escal n Dimensiones Peso Output one step Dimensions Weight HxAxB kvar 440V kvar 400V mm 5 4 1 365x270x170 3 10 38 2 365x270x170 3 12 5 10 365x270x170 3 15 12 5 365x270x170 3 20 16 5 365x270x170 4 25 20 365x270x170 4 Bater a de condensadores esamine Y BasicPlus 440 V 50Hz 150 a pouble porado 9 de 2 escalones Composici n Composition Potencia Output kvar 440V kvar 440V 6 343 9 346 12 6 6 15 3 12 18 6 12 21 6 15 24 12 12 27 12 15 30 15 15 Caracter sticas e Fijaci n mural e Con regulador de la serie Masing FPM e Condensadores ESTAprop e Contactores con resistencias previas para limitaci n de la corriente de conexi n Exclusivamente 2 grupos e Interruptor tripolar de corte en carga e Montado en armario de poli ster RAL 7035 Protecci n mec nica IP30 e Acometida por la parte inferior e Temperatura ambiente admisible 5 C a 35 C media en 24h maximo 40 C 440V Potencia Dimensiones Peso Output Dimensions Weight HxAxB kvar 400V mm 5 500x400x200 13 7 5 500x400x200 13 10 500x400x200 13 1225 500x400x200 13 15 500x400x200 13 17 5 500x400x200 IS 20 500x400x200 13 2245 500x400x200 13 25
112. ies up to 24 kV Serie hasta 36 kV Series up to 36 kV Potencia de conden sadores recomen Potencia de conden dada al 80 de la sadores recomendada potencia nominal al 80 de la potencia Recommended nominal Potencia Potencia reactiva capacitors output at Potencia reactiva a Recommended capa nominal Sn a potencia nominal a rate of 80 of the potencia nominal citors output at a rate Rated Reactive output at transformer rated Reactive output at of 80 of the trans power Sn a rated power power rated power former rated power kVA kvar kvar kvar kvar 2b 2 50 3 100 5 160 10 1 7 5 11 2 10 250 15 0 10 17 3 12 5 400 23 2 15 26 8 20 500 28 9 20 32 5 25 630 353 25 397 30 800 59 2 40 60 8 45 1000 73 0 50 75 0 50 1250 90 0 60 92 5 70 1600 113 6 30 116 8 30 2000 140 0 100 144 0 100 2500 17275 120 175 0 120 Leer mas en la pagina siguiente gt gt Read more on the next page gt gt CYDESA Experts in reactive energy and harmonics 79 80 En el supuesto de que el transformador est trabajando habitualmente con una potencia distinta o para transformadores no normalizados el c lculo de la potencia del condensador deber efectuarse aplicando la expresi n Swila Ux S Y as 00 Sa S Siendo SN potencia nominal del Trafo kVA lo corriente de vac o en 96 u Tensi n de cc en S potencia real de trabajo en kVA Ejemplo Trafo de 630 kVA de potencia nominal con una lo 0 95 u 6 y trabajando al 5096 d
113. igned to allow the Capacitors switching operation and it meets the requirements of the following standards EN 60129 For switch disconnectors and earthing switch disconnectors EN 60265 1 For circuit breakers EN 60470 For vacuum contactors EN 60282 For fuses Safety and protections The series EG equipments don t have protection devices against internal arcs Upon demand we can supply equipments with cabinets that have some openings to release the pressure if an internal arc occurs The explosion risk of the capacitors is practically eliminated thanks to the protection device against internal overpressure and the H R C fuses in 3 phase units and imbalance protection in single phase double star mounts Technical handbook En todo caso y para evitar los posibles riesgos a las personas o bienes es aconsejable ubicar los equipos en zonas aisladas De los dispositivos de protecci n cabe destacar Fusibles generales o por escal n de A P R como equipamiento b sico en todos los equipos Poder de corte gt 50kA Condensadores con dispositivo de control de sobrepresi n que act a al producirse una sobrepresi n interna en el condensador de 0 6 0 8bar Este rel debe actuar sobre el interruptor seccionador de entrada en caso de incorporarse el contactor del escal n o sobre un dispositivo de corte externo En cuanto a las medidas de protecci n para las personas pueden destacarse Pantallas para impedir el acceso a las partes baj
114. io Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio kvar kvar kvar Size Price 400V 440V 480V mm kg A 375 25 50 3x100 454 540 2200x1200x600 358 EGT 400P 375 5 15 15 720 00 800 1 221 00 400 2x50 3x100 484 576 2200x1200x600 362 EGT 400P 400 5 8 16 282 00 1000 2 402 00 425 25 2x50 3x100 514 612 2200x1200x600 370 EGT 400P 425 6 17 17 404 00 1000 2 402 00 450 50 4x100 545 648 2200x1200x600 369 EGT 400P 450 5 9 17 966 00 1000 2 402 00 475 25 50 4x100 575 684 2200x1200x600 383 EGT 400P 475 6 19 18 247 00 1000 2 402 00 500 2x50 4x100 605 720 2200x1200x600 386 EGT 400P 500 6 10 18 527 00 1250 2 791 00 525 25 2x50 4x100 635 756 2200x1200x600 394 EGT 400P 525 7 21 19 370 00 1250 2 791 00 550 50 5x100 666 792 2200x1200x600 393 EGT 400P 550 6 11 19 650 00 1250 2 791 00 575 25 50 5x100 696 828 2200x1200x600 399 EGT 400P 575 7 23 23 579 00 1250 2 791 00 600 6x100 726 864 2200x1200x600 403 EGT 400P 600 6 6 24 703 00 1250 2 91 00 600 2x50 5x100 726 864 2200x1200x600 406 EGT 400P 600 7 12 25 264 00 1250 2 791 00 625 25 2x50 5x100 756 900 2200x1200x600 409 EGT 400P 625 8 25 25 825 00 1600 2 980 00 650 50 6x100 787 936 2200x1200x600 429 EGT 400P 650 7 13 26 386 00 1600 2 980 00 675 25 50 6x100 817 972 2200x1200x600 441 EGT 400P 675 8 27 26 948 00 1600 2 980 00 700 2x50 6x100 847 1008 2200x1200x600 448 EGT 400P 700 8 14 26
115. it to the atmosphere the equivalent of 429g of CO2 So an average household with a 500 kWh consummation per month will emit monthly 214 5 Kg of CO2 to the atmosphere In order to get a better idea about the problem s dimension utilize of the following comparison The emission of 1 kg of CO2 to the atmosphere is produced by 2 3 kWh of electricity consumption 7 9 km made by a small car 3 3 h in an average inhabited house At the same time and for every kvar installed in capacitors it will be possible to avoid the emission of 25kg of CO2 annually 1 1 This is an approximate estimation issued from the available data e pud Technical handbook CX Im ae UNA M m ul Em IA ocu SEN a MENSAE S s A i NM TIPAIPIS xr Y DX ZX f m AX ZA B Av e LL A Pa ae nN YA AN EIN CIN a awe AA ia LA i TI a i a M a E as 1 i ri 4 x po RE Ti A e AT ANSP fi N ZA A A NN WZA Nd Dd T y SY SAY Se TI ay ee SGP DELS SS Val Boi at SS x mY AX NADA X Y i 77 CYDESA Experts in reactive energy and harmonics Manual t cnico Gu a t cnica para la compensaci n de energ a reactiva Technical guide for reactive power compensation La compensaci n de la energ a reactiva puede realizarse En media tensi n Cuando hay
116. it will be possible to obtain 400 kW Se logra un importante ahorro v a tarifas el ctricas El cargo por consumo de energ a reactiva en Espana se calcula por Tr k E reactiva 0 33 E activa Siendo K el factor indicado por la siguiente tabla en 2013 De 1 hasta 0 95 gt 0 8 lt 0 95 lt 0 8 k Precio Euro kvarh 0 041554 0 062332 Tarifas el ctricas sometidas a penalizaci n por reactiva Tarifa tipo 2 0A 2 14 Periodos 1 punta Cargo 0 TR TR oe mejora la tensi n de red Al compensar una instalaci n se reduce la ca da de tensi n y por tanto se aumenta la tensi n disponible Si como es habitual la compensaci n es autom tica y por tanto se mantiene un buen cosq para cualquier valor de la carga se lograr mantener una tensi n con m nimas variaciones por ca das de tensi n Las ca das de tensi n en una red se producen principalmente en los transformadores de potencia y en menor medida en las l neas Al compensar y debido a la mayor reactancia de los transformadores en comparaci n con las l neas la reducci n de las ca das son muy apreciables en los transformadores y despreciables en las l neas A t tulo de ejemplo en una instalaci n alimentada por un transformador de 250kVA se produce una reducci n en la ca da de tensi n de aproximadamente el 65 al pasar de cos q 0 7 a 1 0 y del 22 al pasar de 0 7 a 0 9 CYDESA Expertos en energ a reactiva y arm nicos
117. ith detuned filters are required Finally for values S S higher than 50 we recommend to ask it to our technical department because another filter type may be suitable For S S lt 5 not be considered any limitation to the installation of conventional banks Example 1 Installation with a transformer of 400 kVA with a capacitor bank for compensation of 100 kvar There are ASDs of 110 kVA of simultaneous total power Gaz 100 o O CON 110 S 400 That would lead us between the continuous line and the dotted line therefore an overrated improved capacitor bank premium see page 50 100 2 27 576 Example 2 We take the previous example but with 150 kvar of capacitors output Qc _ 150 Sy 400 Scow Sr In that case we would be over the dotted line and therefore an equipment with detuned filters would be required 100 37 5 27 5 We should remark that the figure 3 1 only gives an elementary guide to choose the most suitable equipment For a more accurate calculation we suggest to ask it to our technical department Technical handbook La distorsi n arm nica Es un par metro que permite calcular el contenido de arm nicos de corriente o tensi n FD o THD La f rmula m s utilizada es TDH 2 4 2 100 Siendo Xh Valor eficaz del arm nico de orden h X1 Valor eficaz de la fundamental As por ejemplo si se miden los siguientes arm nicos en la tensi n simple de red U
118. ition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio kvar kvar kvar Size Price 400V 440V 480V mm kg A 212 5 12 5 2x25 3x50 257 306 1890x580x445 143 EL 400P 212 5 6 17 6 661 00 630 840 00 225 25 4x50 272 324 1890x580x445 148 EL 400P 225 5 9 6 731 00 630 840 00 237 5 12 5 25 4x50 287 342 1890x580x445 150 EL 400P 237 5 6 19 7 043 00 630 840 00 250 2x25 4x50 303 360 1890x580x445 151 EL 400P 250 6 10 7 457 00 630 840 00 275 25 5x50 333 396 1890x580x445 153 EL 400P 275 6 11 8 283 00 630 840 00 300 6x50 363 432 1890x580x445 155 EL 400P 300 6 6 8 710 00 630 840 00 300 2x25 5x50 363 432 1890x580x445 156 EL 400P 300 7 12 8 831 00 630 840 00 325 25 6x50 393 468 1890x580x445 160 EL 400P 325 7 13 957500 800 1 221 00 350 2x25 6x50 424 504 1890x580x445 163 EL 400P 350 8 14 10 099 00 800 1 221 00 375 25 7x50 454 540 1890x580x445 161 EL 400P 375 8 15 10 466 00 800 1 221 00 400 2x25 7x50 484 576 1890x580x445 168 EL 400P 400 9 16 11 320 00 1000 1 627 00 425 25 8x50 514 612 1890x1160x445 256 EL 400P 425 9 17 12 877 00 1000 2 402 00 450 9x50 545 648 1890x1160x445 258 EL 400P 450 9 9 12 952 00 1000 2 402 00 450 2x25 8x50 545 648 1890x1160x445 251 EL 400P 450 10 18 13 322 00 1000 2 402 00 475 25 9x50 5 5 684 1890x1160x445 261 EL 400P 475 10 19 13 785 00 1000 2 402 00 500 10x50 605 720 1890x1160x445 263 EL 400P 500 10 10 14 400 00 1250 2 608 00 500 2x25 9x5
119. izada Es la forma mas habitual de compensar instalaciones donde como es usual hay numerosos receptores Calculo de la potencia de condensadores en una instalacion en proyecto Del proyecto puede extraerse Potencia total instalada PT kW Factor de simultaneidad Fs Cos q medio coso Si se desea alcanzar un cos q la potencia necesaria de condensadores ser Q Pr q tan g tan qa Pras f f valor obtenido de la tabla lll en p gina 106 Ejemplo 1 Instalaci n donde se conoce que la potencia del conjunto de receptores es de 230 kW de los que suelen funcionar el 5096 Se estima un cosq medio de 0 8 y se quiere alcanzar un cosq de 0 98 Se determina f 0 547 por la tabla por tanto 290 mar Q 2230 300 9 547 63 kvar Ejemplo 2 Se pretende compensar una instalaci n alimentada por un trafo de 1000 kVA desconociendo con exactitud la potencia instalada as como el cos q y el factor de simultaneidad Se pueden estimar como valores habituales Cosq 0 8 Cos 0 95 Trafo u 6 y 80 de P C La potencia de condensadores seria OF para el trafo 50kvar tabla en pagina 100 O para receptores 1000 x 0 8 x 0 8 x tan 1 tan 2 1000 x 0 64 x 0 421 269 kvar For motors with static starters is recommended to connect the capacitor before the starter solution a or b of the figure Compensacion de arrancadores estaticos Compensation of soft starters Centralized compensation
120. kVA uk 6 36 kA up to 1250 kVA uk 6 2 series standard and higher rated The standard series can operate permanently at 415V and temporary up to 460V The power is always referred to 400V The higher rated series can operate permanently at 440V and temporary up to 490V The power is always referred to 400V Serie Reforzada Higher rated Series Poten Int Poder de Dimensiones Peso Tipo Precio Potencia Tipo Precio cia Rel corte Dimensions Weight Type Price Output Type Price Output Circuit Breaking H x A A1 x B breaker capacity relay kvar kvar A kA mm kg 400V 50Hz Ejecucion Prismatica Prismatic Equipment 10 160 20 10 520x 260 300 x135 8 PhP 400 10 IA 10 430 00 15 160 30 10 520x 260 300 x135 8 5 PhP 400 15 IA 10 484 00 20 160 40 10 520x 260 300 x135 8 5 PhP 400 20 IA 10 564 00 20 PhP 400R 20 IA 10 596 00 20 160 40 15 520x 260 300 x135 8 5 PhP 400 20 IA 15 645 00 20 PhP 400R 20 IA 15 675 00 25 160 50 10 520x 260 300 x135 9 PhP 400 25 1A 10 615 00 25 PhP 400R 25 IA 10 708 00 25 160 50 15 520x 260 300 x135 9 PhP 400 25 IA 15 721 00 25 PhP 400R 25 IA 15 795 00 30 160 60 10 520x 260 300 x135 10 PhP 400 30 IA 10 780 00 30 PhP 400R 30 IA 10 863 00 30 160 60 15 520x 260 300 x135 10 PhP 400 30 1A 15 847 00 30 PhP 400R 30 IA 15 929 00 35 160 70 25 520x 260 300 x135 11 PhP 400 35 1A 25 1 142 00 35 PhP 400R 35 IA 25 1 204 00 40 160 80 25 520x 260 300 x135 11 PhP 400 40 1A 25 1 225 00 40 PhP 400R 40 IA 25 1 294 00 50 160 100 25
121. l de reactiva para maniobra del contactor e Sistema de corte visible mediante interruptor magnetot rmico de 16 a 40A seg n potencia e Montado en ARMARIO de poli ster RAL 7035 Protecci n mec nica IP30 Lista de Precios 2014_Equipos Capacitor Bank Basic 230V 50Hz in one step Technical Data e Wall mounted e Capacitors ESTAprop e Contactors with resistors prior to current limiting connection e Relay for switching reactive contactors e Disconnection system visible through MCB 16 to 25A depending on power e Polyester cabinet mounted RAL 7035 Mechanical protection IP30 230V Potencia Dimensiones Tipo Precio Output Dimensions Type Price HxAxB kvar mm 2 5 365x270x170 BASIC 230 2 5 605 00 5 365x270x170 BASIC 230 5 636 00 10 365x270x170 BASIC 230 10 766 00 Instalaci n compensada por CYDESA Caja M gica Madrid CYDESA Expertos en energ a reactiva y arm nicos Facilities compensated by CYDESA Magic Box Madrid Price List 2014 Equipment Bateria de Capacitor Bank condensadores Prosec 440 V 50Hz Prosec 440 V 50Hz up to 120 kvar hasta120 kvar Technical Data Caracter sticas e Wall mounted e With Series controller Masing FPM e Fijaci n mural e Capacitors ESTAprop e Con regulador de la serie Masing e Contactors with resistors prior to FPM current limiting connection e Condensadores ESTAprop e Switch disconnector e Contactores con resistencias e Polyester cabinet mounted
122. l teclado e Funcionamiento de 4 cuadrantes para instalaciones con cogeneraci n e Rel s de alarma y de mando del ventilador mediante programaci n y utilizando los 2 ltimos rel s de escalones e Permite seleccionar escalones fijos y fijos en stanby CYDESA Expertos en energ a reactiva y arm nicos I MASING v TI an cose s THE ENSIMA Masing series FPM power factor controller Masing series FPM power factor controllers have a powerful microprocessor that has several functions and services Measurements e Instantaneous cos q e Instantaneous and maximum voltage e Instantaneous and maximum current e Equipment temperature e Record the maximum measured values of voltage current THD and temperature Alarms e Under and overcompensation e Minimum and maximum current on the secondary of CT e Capacitors overload e Overtemperature Protections e Capacitors current overload e Overvoltage e Excess of equipment temperature e Excess of harmonics Other features e Option of automatic set up e Serial interface TTL RS232 to communicate with PC and for set up and testing e Keyboard locking e Operation of 4 quadrants for cogeneration equipment e Alarm and fan control relays by means of programming and using the 2 last step relays e Allow to select fixed steps and fixed in standby Price List 2014 Capacitors Reguladores de energ a reactiva Masing serie FPM Caracter sticas Par metros A
123. la red con valor apreciable The harmonic distortion To calculate de harmonic distortion the most usual expression is EX TDH 100 When Xh Effective value of harmonics h X1 Effective value of the fundamental Thus for example if the following harmonics at the mains voltage U1 230 V U3 3V V5 10V y V7 2V are measured the THD will be 2 4n2 2 LEA io 4 0 Normally the distortion factor doesn t overcome the 5 in industrial installations Higher values should lead to introduce protection measures especially with regard to the capacitor banks For more information see our software CYDESA PFC The resonance It is a well known phenomenon both in electricity and mechanics and it s just an important amplification of a certain magnitude In an electrical installation containing a transformer and a capacitor bank appears a parallel resonance given by where ST transformer power kVA uk transformer impedance O capacitor bank output kvar hr harmonic in resonance _ 100 S ni Uk Q For example 1 takina the value uk 5 it would be _ 100 400 _ a 5 700 9 That is to say the harmonic in resonance is far away from the 5th and the 7th harmonic which are the most important Therefore we shouldn t expect any problem For the example 2 taking again the value uk 5 it would be _ 100 400 _ MT S150 This frequency is too close to the 7th harmonic As a result to ins
124. locar donde m s convenga el condensador el ctrico El condensador es un dispositivo que eligiendo su potencia convenientemente suministra la energ a reactiva necesaria sin necesidad de que sea suministrada por la central el ctrica Debido a esta simplicidad y rendimiento el condensador o la bater a de condensadores es el m todo universalmente utilizado para mejorar el cos o factor de potencia FP como tambi n suele denominarse 1 RED Si el condensador suministra la potencia reactiva necesaria para el motor la central el ctrica solo debe suministrar la potencia activa P en caso contrario deber a suministrar P y O Qu ventajas supone la compensaci n de la energ a reactiva De la exposici n anterior se desprenden las ventajas m s Importantes 5e reducen las p rdidas lo cual se traduce en ahorro de energ a es decir de kWh Al compensar la energ a reactiva evitamos que parte o la totalidad de esta seg n elijamos deba circular por la red lo cual conlleva a su vez una reducci n de la corriente el ctrica circulante Al ser las p rdidas proporcionales al cuadrado de la corriente se comprende la importancia de esta reducci n Adem s como la corriente el ctrica tambi n debe circular por los transformadores tambi n en estos se producir una reducci n importante de p rdidas A t tulo de ejemplo pasar de un cos de 0 75 a 0 9 en una instalaci n alimentada por un transformador de 400 kVA se
125. ltage Fig 6 2 Limitaci n de la corriente de conexi n de un condensador a Mediante una inductancia limitadora conectada en serie L b Mediante una resistencia R insertada s lo en el instante de conexi n Limitation on power of a capacitor a Through a series connected limiting inductance L b through a resistor R inserted only at the instant of connection Technical handbook i V 2S V 0 I 20 30 1 Fig 6 3 Corriente del transitorio de conexi n de condensadores A Condensador individual B Condensador conectado en paralelo valor de pico de la corriente de conexi n del condensador A Valor eficaz de la corriente nominal del condensador A S Potencia de cortocircuito MVA en el punto de conexi n del condensador O Potencia de la bater a MVAr U Tensi n de red kV X Reactancia capacitiva serie por fase X Reactancia inductiva por fase entre bater as f Frecuencia del transitorio f y Frecuencia de red Q Potencia del conjunto de condensadores en paralelo con O MVAr 1 Ejemplo Sup ngase en la figura 6 3 una potencia del transformador de 1000kVA 400V con una tensi n de c c del 6 y 2bkvar 400V de potencia de condensador O V3 U 25 V3x0 4 36A S S u 1 0 06 16 7 MVA i 36 Y 2 x 16 7 0 025 1316 A 261 i U V2 V XX fs fao X X l 30 250 I siendo X 3U 1 0 1 0 10 being X 3U 1
126. n carga Extra price for switch disconnector Calibre Precio Size Price A 8 422 00 250 500 00 8 984 00 250 500 00 9 544 00 400 592 00 10 106 00 400 592 00 10 668 00 630 840 00 11 229 00 630 840 00 12 352 00 630 840 00 12 634 00 630 840 00 12 913 00 630 840 00 13 194 00 800 1 221 00 13 475 00 800 1 221 00 14 035 00 800 1 221 00 15 720 00 1000 2 402 00 16 282 00 1000 2 402 00 16 563 00 1000 2 402 00 16 843 00 1000 2 402 00 17 404 00 1250 2 91 00 17 966 00 1250 2 791 00 18 247 00 1250 2 791 00 20 211 00 1250 2 791 00 20 773 00 1250 2 791 00 20 922 00 1250 2 791 00 22 457 00 1600 2 980 00 23 579 00 1600 2 980 00 24 141 00 1600 2 980 00 24 703 00 1600 2 980 00 Other extra prices e Residual current circuit breaker on page 65 1 It is not possible to include a switch disconnecter without increasing the cubicle dimensions see next type CYDESA Experts in reactive energy and harmonics 51 Lista de Precios 2014_Equipos Standard capacitor bank EC ED EL 230V bOHz Bater as de condensadores estandar EC ED EL 230V bOHz Caracter sticas Technical data e Technical data on page 44 e With FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Incoming at the bottom e Extra price for residual current circuit breaker e Floor mounted e Caracter sticas generales en p g 44 e Con regulador FPM ver p g 22 e Condensado
127. n caso de sobrepresi n interna e Temperatura ambiente admisible 5 C a 35 C media en 24h m ximo 40 C e Protecci n IP30 e Acabado color RAL 7035 e P rdidas 1 2W kvar 400V 1 9W kvar 230V 6W Kvar 400V para equipos con filtros Ejecuci n Est ndar para redes a 400V soport n permanente mente 415V y de forma temporal 460V Premium EC ED 400P EL 400P y EG 400P para sobretensiones sobreintensidades y temperaturas que excedan lo indicado en CEl 61921 2003 EN 61921 Ver p g 48 y 50 e Standards CEl 61921 2003 EN 61921 Low voltage capacitor banks for the power factor correction e Electrical protection fuse and capacitors security device with an internal overpressure tear off fuse e Acceptable ambient temperature 5 C to 35 C average in 24h maximum 40 C e Protection IP30 e Painting colour RAL 7035 e Losses 1 2W kvar 415V 1 9W kvar 230V 6W kvar 400V for equipments with filter circuits The Standard equipment can operate at 415V with a tempo rary overvoltage of 460V The Premium equipment EC ED 400P EL 400P and EG 400P can operate at overvoltage over current and temperatures that exceed the CEI 61921 2003 EN 61921 See page 48 and 50 Serie Rango de Regulador Acometida Dimensiones Montaje Esquemas Series potencias Controller Incoming Dimensions sobre Drawings Output range HxAxB Mounted kvar 400V mm on EB i 5 25 Masing RINT inferior Below 365x260x160 Muro Wall j 1 esc
128. n cuanto al riesgo de explosi n de los condensadores queda pr cticamente eliminado por el dispositivo de protecci n por sobrepresi n interna y por los fusibles de A P R en unidades trif sicas y la protecci n por desequilibrio en montajes monof sicos de doble estrella CYDESA Expertos en energ a reactiva y arm nicos CYDESA manufactures a wide range of equipments with capacitors up to 24kV for the fix compensation and up to 12kV for the automatic compensation The switchgear together with the capacitors and other devices for measurement protection and indication are assembled in metalic cabinets of steel sheet with triangular profiles assembled to the top and bottom frames by means of 1 5mm thickness panels and doors of 2mm Once the sheet has been properly treated a paint of polyester epoxy resine with a texturized colour RAL 7032 is applied For weatherproof performance can be provided in stainless steel Supply entry The cables for the supply entry are designed to be connected directly to the busbar or entry device A supporting base allows fixing them in order to avoid the terminals traction efforts Busbar The electrolytic copper bars are assembled on insulators of epoxy resine in horizontal position and on the upper part of the cabinet Their design allows assuring a short circuit strength higher than 30kA Higher values up to 100kA are available on request Switchgear The whole switchgear has been specially des
129. n en voltios V Existe una confusi n que es preciso clarificar al respecto de la definici n de estas dos magnitudes La potencia reactiva var a con la tensi n como muestra la ecuaci n Oe Ue Ur x Or Donde Oe es la potencia que obtendremos a la tensi n Ue que soportar n los condensadores Ue es la tensi n que aplicaremos a la bater a normalmente la tensi n de red Ur es la tensi n asignada o nominal para la que se ha fabricado la bater a y que le permite trabajar de forma permanente de acuerdo con la norma EN 60831 1 y 2 Or la potencia asignada o nominal resultante de aplicar a la bater a de tensi n asignada para la que ha sido fabricada Ejemplos Una bater a de 100kvar cuya tensi n asignada es 440V si se le aplica la tensi n de red de 400V dar una potencia efectiva de 82 kvar un 18 menos que si se instalara una bater a de 100kvar a 400V Para que una bater a de 440V de tensi n asignada entregue una potencia til de 100kvar a 400V deber tener una potencia de 121kvar CYDESA Expertos en energ a reactiva y arm nicos Manual T cnico_Tablas y formulario Voltage rise The capacitors networked produce inductive voltage increase to effect voltage regulation used in electrical networks The O of the capacitor is connected to a point with a network short circuit power S leading to overvoltage AU 100 K This phenomenon often occurs in transformers capacitive load Typical
130. n p 0 activa Con este dato la tabla proporciona el cos existente correspondiente reactive P active With this information the table gives us the corresponding Una vez elegido el cos q que se desea puede determinarse el factor f y con cos Once the desired cos q has been chosen we can determine the f factor ello la potencia necesaria de condensadores O P f and with it the required power of the capacitors O P f 106 CYDESA Expertos en energ a reactiva y arm nicos Technical handbook Tables and formularies 400V 40 C Cable interruptor y fusibles para condensadores individuales y bater as a 400V 50 Hz Cable switch disconnector and fuses for single capacitors and banks at 400V 50 Hz Potencia Corriente Secci n del conductor de cobre seg n el modo de instalaci n Interruptor Interruptor sec Output asignada para 40 C de temperatura ambiente y aislamiento de XLPE magnetot rmi cionador calibre a 400V 0 6 1kV 1 3 Copper conductor cross section depending co regulaci n fusible Rated on the installation type for 40 C of ambient temperature and t rmica 4 Disconnector current at insulation of XLPE 0 6 1kV 1 3 4 Circuit fuse 400 V B2 1 E 1 F 1 ee Inn cable tripolar cable tripolar cable unipolar N de In ir multicore multicore cables por fase x secci n cable cable single core cable Number of cables per phase and Oc len cross section er A mm mm mm A A
131. n se montan en un armario met lico de chapa de acero con perfiles triangulares fijados a marcos superiores e inferiores con paneles de 1 5mm de espesor y puertas de 2mm reforzadas Una vez tratada la chapa de forma adecuada se le aplica una pintura a base de resina de poli ster epoxi de color RAL 7032 texturizado Para ejecuci n de intemperie se puede suministrar en acero inoxidable Acometida Los cables de acometida est n previstos para conectar directamente al embarrado o dispositivo de entrada disponiendo de un soporte que permite fijarlos para evitar esfuerzos de tracci n en los terminales Embarrado Las barras de cobre electrol tico se montan sobre aisladores de resina epoxi en disposici n horizontal y en la parte superior del armario Su dise o permite asegurar una resistencia a cortocircuito superior a 30kA Pueden solicitarse valores superiores hasta 100kA Aparamenta Toda la aparamenta ha sido especialmente elegida para permitir la maniobra de condensadores y cumple con las siguientes normas EN 60129 Para seccionadores y seccionadores de puesta a tierra EN 60265 1 Para interruptores seccionadores EN 60470 Para contactores de vac o EN 60282 Para fusibles Seguridad y protecciones La serie de equipos EG no disponen de dispositivos de protecci n contra arcos internos bajo demanda podemos suministrar equipos con armarios dotados de aperturas para liberar la presi n en caso de producirse un arco interno E
132. n usually find the most part of the loads that absorb reactive energy loads at 400V supplied by the secondary of T1 at the figure For each load Solution taken when there are few high power loads for example motors like M1 M2 1 y M2 2 at the Figure 1 1 It is also usual to connect a fix capacitor in order to compensate the reactive power of the transformers OT1 y OT2 at the figure The compensation at load terminals has as advantage the possibility to discharge the whole network from the load terminals upstream to the supply With a centralized automatic capacitor bank At the most part of installations the large number of loads recommends to compensate with a centralized capacitor bank or with a centralized automatic equipment connected to the general busbar of the transformer output Equipment O1 at the figure 20kV T2 1250kVA 7 6kV Q T2 Q M2 1 Q M2 1 M2 1 M2 2 400kW 650kW Technical handbook Tabla Table Compensacion de transformadores Transformer compensation Potencia reactiva de condensadores Reactive power of recommended recomendada para compensaci n de capacitors to compensate the la reactiva propia del transformador se transformer reactive power we supone que el trafo est al 80 desu assume that the transformer is being potencia nominal used at a rate of 80 of its rated power Compensaci n de transformadores Transformer compensation Serie hasta 24 kV Ser
133. ntrol device for the overpressure that acts when an internal overpressure in the capacitors of 0 6 0 8bar occurs This relay should act on the circuit breaker from the entry if included on the step contactor or on an external breaking device Concerning the protection measurements for the people we should remark Screen to prevent the access to the areas with voltage even if the door is open Optional locking device that prevents the opening of the door if the switch has not been disconnected before and or the three entry phases are not grounded The low voltage control devices are located in a compartment or in a metallic box of the upper part of the equipment The operational cables that entry inside the equipment are placed in steel tubes grounded together with the box All the non active conductive parts are properly connected to a bar or earthing terminal During the assembly and the appropiate tests the connections and the continuity of the protection circuit are checked Tests With independence of the special tests for the switchgear carried out by the manufacturer the capacitors are submitted to the tests mentioned in EN 60871 1 Regarding the equipments they are submitted to the individual tests of the standard EN 60298 Switchgear with metallic enclosing for alternating current of rated voltages higher than 1kV and equal or lower than 52kV CYDESA Experts in reactive energy and harmonics 97 98 Cara
134. o Type Dimensions Opening Power Price VA Clase 1 3 mm mm Class 1 3 IAP 100 5 123x120 51x41 1 25 2 5 117 00 IAP 200 5 123x120 51x41 S 75 3 75 117 00 IAP 300 5 123x120 51x41 5 10 131 00 IAP 400 5 123x120 51x41 7 5 20 131 00 IAP 500 5 123x120 51x41 10 30 131 00 IAM 600 5 155x159 81x81 7 5 20 147 00 IAM 750 5 155X159 81x81 15 30 147 00 IAG 1000 5 200x163 126x81 15 30 455 00 IAG 1500 5 200x163 126x81 30 60 466 00 IAG 2000 5 200x163 126x81 60 60 477 00 IAG 3000 5 200x163 126x81 60 60 545 00 Transformadores de corriente Adding current transformers sumadores Tipo Dimensiones Potencia Precio Type Dimensions Power Price VA Clase 1 3 mm Class 1 3 TS 5 5 5 72x121 15 262 00 TS 5 5 5 5 72x121 1 5 2 5 343 00 CYDESA Expertos en energ a reactiva y arm nicos pacitors Price List 2013 Ca Facilities compensated by CYDESA Telefonica Tower Barcelona Instalaci n compensada por CYDESA Torre Telef nica Barcelona 29 CYDESA Experts in reactive energy and harmonics Lista de Precios 2014 Componentes Componentes para la compensaci n de energ a reactiva en instalaciones con arm nicos Components for power factor correction in installations containing harmonics Reactancias para filtros de rechazo para arm nicos fr 189HZ Reactancias trif sicas con n cleo de hierro devanados de cobre o aluminio y terminales de cobre Impregnadas al vac o sobrepresurizadas en resina de poli ster y secados
135. o tensi n a n con la puerta abierta Dispositivo de bloqueo opcional que impide la apertura de la puerta si antes no se desconecta el interruptor seccionador general y o se ponen a tierra las tres fases de entrada Los dispositivos de mando y control de baja tensi n est n ubicados en un compartimiento o caja met lica en la parte superior del equipo los cables de maniobra que penetran en el interior del equipo est n alojados en tubos de acero puestos a tierra junto con la caja Todas las masas o partes conductoras no activas est n adecuadamente conectadas a una barra o terminal de puesta a tierra Durante el montaje y los pertinentes ensayos se comprueban las conexiones y continuidad del circuito de protecci n Ensayos Con independencia de los ensayos particulares a que el fabricante somete a la paramenta los condensadores se someten a los ensayos mencionados en CEl 871 1 EN 60871 1 En cuanto a los equipos stos se someten a los ensayos individuales de la norma EN 60298 Aparamenta bajo envolvente met lica para corriente alterna de tensiones asignadas superiores a 1kV e inferiores o iguales a 52kV In any case and in order to avoid possible risks for the people or goods we strongly recommend to locate the equipments in isolated areas Among the protection devices we should highlight General fuses or by step of H R C as an essential part in all the equipments Breaking capacity gt 50kA Capacitors with a co
136. oftware pack 150 150 1 It is not possible to include a switch disconnector without increasing 1 No es posible incorporar interruptor sin aumentar las dimensiones the cubicle dimensions see next type del armario ver tipo siguiente 2 On request 2 Bajo demanda CYDESA Experts in reactive energy and harmonics 57 58 Equipo Premium EGT Equipment of the EGT Premium Potencia Composi n Output Composition kvar 400V 100 2x25 1x50 125 25 2x50 150 3x50 175 25 3x50 200 2x25 3x50 225 25 4x50 250 2x25 4x50 275 25 5x50 300 6x50 325 25 2x50 2x100 350 50 3x100 kvar 440V 121 151 182 212 242 272 303 Sus 363 393 424 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 e Suplemento por dispositivo comunicador Modbus Sotware 150 kvar 480V 144 180 216 252 288 324 360 396 432 468 504 CYDESA Expertos en energ a reactiva y arm nicos Bater as de condensadores Premium EDT EGT 400P con contactores est ticos Caracter sticas e Caracter sticas generales en p g 44 e Con regulador de la serie FPM ver p g 22 e Condensadores ver p g 8 e Interruptores est ticos ver p g 26 e Autotrafo de maniobra 400 230V e Acometida por la parte inferior e Protecci n diferencial opcional e Fijaci n sobre suelo 400V 50Hz Dimensiones Peso Tipo Precio Suplemento Dimensions Weight Type Price interrupt
137. oltage U lt 1kV Medium voltage 1kV lt U lt 36kV High voltage 36kV lt Us72 5kV High voltage 72 5kV lt U lt 145kV Very high voltage U gt 145kV A ZVEI study on March 2006 for Europe EU25 suggest to pass from a 0 91 to a 0 97 average cos q on the networks which would have to make possible to save 18TWh this is 18 000 millions of KWh per year If this number were extrapolated to Spain that would mean 1 8TWh a number higher than a 250 MV power station production working 6600h per year This would have represented a 772 thousand tonnes saving of in the emission of greenhouse effect gases per year Greenhouse Gases GHG Emission Main components of Greenhouse Gases are carbon dioxide CO2 methane CH4 and nitrous oxide N20 they all together represent 99 of GHG Among them CO2 represents 84 of the total 1997 Kyoto Protocol involved a commitment for reducing Greenhouse Gases in 38 of the most developed countries during the 2008 2012 period regarding those from 1990 This reduction represents 8 for the UE which attributed a 15 increase to Spain However Spain has increased these emissions 52 9 in 2005 regarding to 1990 hence the difficulty to carry out Kyoto statements which constrain to buy emission allowances according to the mechanisms included in such protocol Since Spanish Government distributes emission allowances among all different sectors and industries at the end companies are committed either to respec
138. ood the decrease or elimination of that circulation since its consumption by motors or other machines and electric equipments is inevitable as mentioned previously In Electrotecnics three concepts of power are considered active P reactive Q and apparent S whose relationship among them is as follows s2 P2402 This is depicted using a right angled triangle Electric powers triangle S o P Since the difference between power and energy is time service hours what is exposed before is also useful for the respective energies COS zt Yos In the figure is distinguished that the bigger the angle q is the higher will be the reactive power Q regarding to the active one P and vice versa Therefore compensating reactive energy is equal to reduce q angle and in consequence enlarge its cosine Then the better the cos q that is the closer to the unit the higher will be the active power that could be transported through the network and whose maximum capacity is the apparent power Pmax S 1 The term energy may be confusing since there is not a clear physic sense such reactive energy then it is an electrotechnic concept Technical handbook Qui n suministra la energ a reactiva Al igual que la energ a activa la energ a reactiva a falta de otra fuente ser suministrada por una central el ctrica y conducida por la red Pero existe otra fuente de energ a reactiva muy asequible y f cil de co
139. or de corte HxAxB en carga Extra price for switch disconnector Calibre Precio Size Price mm kg A 1300x600x660 237 EDT 400P 100 3 4 8 984 00 250 500 00 1300x600x660 238 EDT 400P 125 3 5 9 544 00 250 500 00 1300x600x660 248 EDT 400P 150 3 3 10 106 00 400 592 00 2100x600x600 317 EGT 400P 175 4 7 11 790 00 400 592 00 2100x600x600 237 EGT 400P 200 5 8 12 352 00 630 840 00 2100x600x600 325 EGT 400F 225 5 9 12 918 00 630 840 00 2100x600x600 337 EGT 400P 250 6 10 13 727 00 630 840 00 2100x600x600 341 EGT 400P 275 6 11 14 035 00 630 840 00 2100x600x600 347 EGT 400P 300 6 6 14 597 00 630 840 00 2200x1200x600 339 EGT 400P 325 5 13 14 879 00 800 1 221 00 2200x1200x600 341 EGT 400P 350 4 7 15 159 00 800 1 221 00 Lista de Precios 2014_Equipos Premium capacitor bank EDT EGT 400P with static contactors Technical Data e Technical data on page 44 e With series FPM controller see page 22 e Capacitors see page 8 e Static contactors see page 26 e Autotrans for aux voltage 400 230V e Incoming at the bottom e Optional residual current protection e Floor mounted Other extra prices e Residual current circuit breaker on page 65 e Modbus device Software pack 150 Price List 2014 Equipment Bater as de condensadores Premium Premium capacitor bank EDT EGT EDT EGT 400P con contactores 400P with static contactors est ticos continuaci n continuation 400V 50Hz Potencia Composi n Dimensiones Peso Tipo Prec
140. or fire With the M V capacitors it s not possible to rule out completely the explosion risk and as a consequence the fire of the impregnant oil Because of that the side of erection should respect the safety distances the emergency exits etc CYDESA Experts in reactive energy and harmonics 93 94 Compensaci n de motores de M T Para evitar la autoexcitaci n puede emplearse los valores indicados en la tabla siguiente con lo que se consigue un cosq de aproximadamente 0 95 Si no hay riesgo de autoexcitaci n o bien el condensador se conecta con un contactor independiente puede aumentarse sin riesgo la potencia del condensador hasta alcanzar el cos deseado as para alcanzar un cos de 0 97 ser a necesario una potencia un 27 superior a lo indicado o bien si se conoce el cos del motor puede efectuarse el c lculo tradicional Compensaci n de motores con limitaci n de potencia de condensadores para evitar el riesgo de autoexcitaci n Manual t cnico M V Motors compensation To avoid the self excitation the values mentioned in the following table can be respected and with these values a cosq of approximately 0 95 can be reached If the self excitation risk doesn t exist or the capacitor is connected with an independent contactor the capacitor output can be increased without risk up to the desired cosq Therefore to reach a coso of 0 97 either an output 27 higher than the one mentioned in the tables should be
141. or the transformer can be loaded in a close future up to 80 or 100 it is better to consider the future situation therefore if the same expression is applied for the 100 of its rated power the capacitor power would be 630 0 95 6 Q 100 700 9830 43 8 kvar To compensate the transformer with a fix overrated step Compensaci n de un transformador y de los receptores OF para el trafo y OA para los receptores Compensation of a transformer OF for the transformer and OA for the loads OF fix step for the transformer reactive power compensation is connected before the CT for the automatic capacitor bank controller Masing FPM regulator avoids the installation of a separate capacitor using the stand by option OA automatic capacitor bank to compensate the transformer loads Technical handbook Tabla II Table Il Compensaci n de motores Potencia Motors compensation de motores as ncronos normalizados Power standard asynchronous motors junto a la potencia de condensadores with the power capacitor recomendada recommended Compensaci n de Motores Motors compensation Potencia del Potencia del Potencia del Potencia del Condensador Condensador Condensador Condensador kW Capacitor output Capacitor output Capacitor output Capacitor output kW Oc kvar Oc kvar Oc kvar Oc kvar 3000 r p m 1500 r p m 1000 r p m 750 r p m 55 L5 25 25 5 0 50 7 5 10 2 5 5 0 5 0 7 5 11 1s 2 5 5 0 75 10 0 15 20 5
142. ors output to compensate a transformer of 12MVA first when unload and then when it has a load of the 80 of the rated power Required output if unload 0 85 x 12 000 100 102 kvar Output at a rate of 80 of the full load 9 x 12 000 102 100 0 8 793kvar Single phase capacitors Single units or capacitors banks with single or double star which can also include an unbalance protection can be provided They usually have internal fuses that together with the unbalance protection represent a safety protection against internal breakdowns Externally they always have to include extra protections Voltage kV 1 a24 50 1000 Three phase capacitors They can be provided with terminals with protection IP55 or without IPOO They cannot include internal fuses They can be provided with a pressure sensor with changeover contact which acts on an external operating device in order to protect in case of internal failure together with external fuses Voltage kV 1a 12 20 800 CYDESA Experts in reactive energy and harmonics 95 96 Manual t cnico EQUIPOS para compensaci n de energ a reactiva en M T M V Equipments for power factor correction CYDESA construye una amplia gama de equipos con condensadores hasta 24kV para compensacion fija y hasta 12kV para compensaci n autom tica La aparamenta junto con los condensadores y otros dispositivos de medida protecci n y o se alizaci
143. orte en carga Incoming at the bottom e Autotransformador de maniobra e Montado en ARMARIO de poli ster RAL 7035 Protecci n mec nica IP30 e Acometida por la parte inferior 440V 50Hz Potencia Composici n Potencia Dimensiones Peso Tipo Calibre int Precio Output Composition Output Dimensions Weight Type Switch Price HxAxB size kvar 440V kvar 400V mm Kg A 135 15 30 30 60 112 5 1170x785x460 50 PROSEC 135 250 4 505 00 150 30 60 60 125 1170x785x460 52 PROSEC 150 250 4 587 00 165 15 30 60 60 137 5 1170x785x460 54 PROSEC 165 400 4 909 00 180 30 30 60 60 150 1170x785x460 56 PROSEC 180 400 5 012 00 195 15 30 30 60 60 162 5 1170x785x460 58 PROSEC 195 400 5 396 00 210 30 60 60 60 175 1170x785x460 60 PROSEC 210 400 5 455 00 225 15 30 60 60 60 197 5 1170x785x460 62 PROSEC 225 400 5 962 00 240 30 30 60 60 60 200 1170x785x460 64 PROSEC 240 630 6 105 00 Baterias automaticas de condensadores Masing Masing automatic capacitor banks 42 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment ento 1 Doble aislar ed isolat Double 15 rporado tor MC inte disconnecto Bater a de condensadores Prosec 230 V 5OHz hasta 50 kvar Caracter sticas e Fijaci n mural e Con regulador de la serie Masing FPM e Condensadores ESTAprop e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Interruptor tripolar de corte en carga e Montado en
144. ossibility to purchase the current transformer for the installation The current transformer of small dimensions allows the installer to install the equipment in an easy way Determinados suministros tienen un bajo consumo de energ a reactiva suficiente como para que la compania les penalice pero que a su vez no es suficiente como para amortizar una bater a de condensadores tradicional Los equipos de la serie EB tienen como objeto ofrecer una soluci n econ mica para este tipo de consumidores con una potencia ajustada a cada necesidad El equipo EB se compone de un nico escal n controlado por un rel de reactiva que funciona de forma an loga a un regulador Cuando el cliente consume energ a el rele Masing RINT calcula el Cos y a partir de un determinado valor procede a la conexi n del condensador El rel Masing RINT permite ajustar e El Cos q a partir del cual el equipo se desconecta e El Cos q a partir del cual el equipo se conecta e El tiempo de conexi n desconexi n e Funcionamiento autom tico manual Posibilidad de adquirir el equipo con el transformador de intensidad dimensionado para la instalaci n Este Tl de reducidas dimensiones permite una sencilla instalaci n del equipo Caracter sticas Technical data e Caracter sticas generales en p g 44 e Technical data on page 44 e Fijaci n sobre pared e Wall mounted e Con rel Masing RINT e RINT Masing relay e Condensadores ver p g 8 e Capa
145. previas para limitaci n de la corriente RAL 7035 Mechanical protection IP30 de conexi n e Incoming at the bottom e nterruptor tripolar de corte en carga e Acceptable ambient temperature 5 C e Montado en armario de poli ster to 35 C average in 24h maximum RAL 7035 Protecci n mec nica IP30 40 C e Acometida por la parte inferior e Temperatura ambiente admisible 5 C a 35 C media en 24h maximo 40 C 440V 50Hz Potencia Composici n Potencia Dimensiones Peso Tipo Calibre int Precio Output Composition Output Dimensions Weight Type Switch Price HxAxB size kvar 440V kvar 400V mm Kg A 12 34346 10 500x400x200 14 PROSEC 12 63 1 376 00 15 3 6 6 125 500x400x200 14 PROSEC 15 63 1 385 00 17 5 2 5 5 10 14 5 500x400x200 14 PROSEC 17 63 1 395 00 21 3 6 12 175 500x400x200 14 PROSEC 21 63 1 412 00 225 2 5 10 10 16 2 500x400x200 14 PROSEC 22 63 1 415 00 24 646412 20 500x400x200 14 PROSEC 24 63 1 422 00 25 5 2x10 20 7 500x400x200 14 PROSEC 25 63 1 427 00 27 3 12 12 23 0 500x400x200 14 PROSEC 27 63 1 439 00 30 5 12 5 12 5 29 500x400x200 14 PROSEC 30 63 1 449 00 36 6 15 15 30 600x500x250 19 PROSEC 36 125 1 670 00 39 3412424 32 5 600x500x250 20 PROSEC 39 125 1 685 00 42 6 12 24 39 600x500x250 20 PROSEC 42 125 1 695 00 45 3 6 12 24 375 600x500x250 20 PROSEC 45 125 1 861 00 50 10 2x20 41 3 600x500x250 20 PROSEC 50 125 1 877 00 54 6412412424 45 600x500x250 20 PROSEC 54 125 1 898 00 60 64215415424 50 600x500x250 20 PROSEC
146. r conectarse un modelo de 4 hilos si se pretende compensar todas las cargas incluidas las monofasicas El campo de aplicaci n los filtros ECOsine Active cubre pr cticamente todas las reas de la industria y los servicios destacando Estaciones de bombeo Donde el empleo de VdF hace dif cil el empleo de filtros pasivos por su aportaci n de energ a reactiva capacitiva a la red Edificios de oficinas hospitales y hoteles En donde la compensaci n del tercer arm nico evitando la sobrecarga del conductor neutro es uno de los requisitos importantes Aplicaciones de soldadura Donde la compensaci n de reactiva y arm nicos exige una gran velocidad de respuesta Aqui el filtro ECOsine Active tiene un tiempo de respuesta din mico de tan solo 300 micro segundos Ascensores Donde es necesaria una r pida y sobre todo una gran frecuencia de maniobras que no es viable con sistemas de compensaci n con contactores En energ a renovables Como plantas solares y parques e licos donde se exige una calidad de la energ a entregada a la red dif cil de conseguir por otros medios zu m The figure shows the connection of ECOsine 3 and 4 wire If the receivers are three phase or single phase loads are scarce or non distorting can be employed a 3 AF wire as shown in figure you must connect 4 wire model if you want to compensate all loads including single phase The scope ECOsine Active filters covers vir
147. r tanto es suficiente con la fijas a bornes del condensador teniendo en cuenta que el regulador tenga un tiempo Capacitor Switching contactors The contactors K3 K are specially recommended for capacitors operation due to the previous contacts that insert the limitation resistors disconnecting them when the main contacts are closed By this way the inrush current produced with the switch on of the capacitor practically disappears The reduction of the current on switching transient avoids the contact welding as well as other possible main distortions With this contactor type the fast discharge resistors are not necessary therefore it is enough with fix resistors connected to the capacitors terminals provided that the controller has a minimum reconnection time of 20s m nimo de reconexi n de 20s Tipo Type K3 18K10 K3 24K00 K3 32K00 K3 50K00 K3 62K00 K3 74K00 K3 115K00 75 00 94 00 104 00 158 00 178 00 238 00 300 00 Tension de aislamiento Ui V 690 690 690 690 690 690 690 Insulation voltage Duracion el ctrica x10 250 150 150 150 150 120 120 Electrical contact life Maxima frecuencia de maniobras 1 h 120 120 120 120 120 80 80 Highest operation frequency Potencia nominal kvar Rated power 220 230V 6 11 14 20 28 33 55 380 400V 12 5 20 25 33 3 50 75 1 100 415 440V 13 22 27 36 53 75 103 660 690V 20 33 41 55 82 120 170 Corriente nominal le Al 18 28 35 48 72 105 144 Rated current Temperatura ambiente a
148. ra las respectivas energias COS a e s En la figura se aprecia que cuanto mayor sea el ngulo q mayor ser la potencia reactiva O respecto a la activa P y viceversa Por tanto compensar la energ a reactiva es sin nimo de reducir el ngulo y en consecuencia aumentar su coseno Como mejor sea el cos q es decir cuanto m s se acerque a la unidad mayor ser la potencia activa que puede transportase por la red cuya capacidad m xima es la potencia aparente Pmax S 1 El t rmino energ a quiz s pueda prestarse a confusi n ya que no tiene un sentido f sico claro como la energ a activa es pues un concepto electrot cnico CYDESA Expertos en energ a reactiva y arm nicos Manual t cnico Reactive energy compensation a profitable investment that helps in the struggle against global warming What Is reactive energy In order to start a machine a motor is needed as well as electrical energy consumption as it often occurs in case of electric motors This type of energy is known in Electrotechnics as active energy However for starting a motor a magnetic field is essential and in order to generate it magnetizing reactive current is required which produces reactive energy 1 for generation this one no useful power is necessary then it will not consume more primary energy than necessary to cover losses produced by circulation through the electric network By compensation of reactive energy it is underst
149. rated series can operate permanently at 440V and La serie reforzada soporta 440V de forma permanente y hasta 490V temporalmente La potencia siempre est referida a 400V temporary up to 490V The power is always referred to 400V Serie Est ndar Standard Series Serie Reforzada Higher rated Series Potencia Dimensiones Peso Tipo Precio Potencia Tipo Precio Output Dimensions Weight Type Price Output Type Price kvar H x A A1 x B mm kg kvar 400V 400V 50Hz 10 430x 183 224 x98 5 PhP 400 10 231 00 T5 520x 195 236 x135 6 PhP 400 15 284 00 20 520x 195 236 x135 6 5 PhP 400 20 313 00 20 PhP 400R 20 359 00 25 520x 195 236 x135 6 5 PhP 400 25 342 00 29 PhP 400R 25 392 00 30 520x 195 236 x135 8 PhP 400 30 433 00 30 PhP 400R 30 528 00 35 520x 260 300 x135 9 PhP 400 35 473 00 30 PhP 400R 35 542 00 40 520x 260 300 x135 9 PhP 400 40 540 00 40 PhP 400R 40 593 00 50 520x 260 300 x135 10 PhP 400 50 582 00 50 PhP 400R 50 666 00 60 520x 260 300 x135 11 PhP 400 60 696 00 70 520x 395 435 x135 13 PhP 400 70 810 00 60 PhP 400R 60 805 00 75 520x 395 435 x135 14 PhP 400 75 827 00 70 PhP 400R 70 900 00 80 520x 395 435 x135 15 PhP 400 80 952 00 75 PhP 400R 75 930 00 100 520x 395 435 x135 17 PhP 400 100 1 040 00 80 PhP 400R 80 1 049 00 230V 50Hz 10 520x 195 236 x135 6 5 PhP 230 10 351 00 15 520x 195 236 x135 7 PhP 230 15 480 00 20 520x 195 236 x135 9 PhP 230 20 621 00 25 520x 260 300 x135 10 PhP 230 25 738 00 30 520x 260 300 x135 11 PhP 230 30 84
150. refore are suitable for installations where most three phase loads with a very small number of single phase loads e 4 wire three phase systems with predominantly single phase loads loads typical office buildings The neutral supports current up to 3 times the phase in anticipation of a dominant third harmonic The filter 4 may also be used in wire manufacturing facilities with or without phase loads but neutral Dimensioning One of the questions before choosing performance is dimensioned to be covered by the filter as compensation are Harmonic currents May offset the odd harmonics of order 3 49 however from 25 is reduced harmonic current progressively filtering to 50 Capacity to the 49th harmonic Software also can choose the percentage for each harmonic compensation This feature is of great interest since that reduce or eliminate harmonics preferably those that exceed such limits certain rules or may cause resonances or network disturbances Reactive current You select both the percentage of compensation as the power factor setpoint At least the AF compensate the percentage AF adjusted even exceeds the setpoint So if the power factor of the network at a given time is higher than the cos setpoint the AF also compensate the programmed rate Current Imbalance It is common in installation with a single phase loads such as the case of offices an imbalance between the phase currents This imbalance can overload cables produ
151. res ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Acometida por la parte inferior e Consultar para suplemento por interruptor diferencial e Fijaci n sobre suelo 230V 50Hz Potencia Dimensiones Peso Tipo Precio Suplemento Composici n Dimensions Weight Type Price interruptor de corte Output HxAxB en carga Composition Extra price for switch disconnector Calibre Precio Size Price kvar mm kg A Series EC ED 7 5 2 5 5 500x400x200 22 EC 230 7 5 2 3 1 154 00 63 130 00 12 5 2 5 2x5 500x400x200 24 EC 230 12 5 3 5 1 445 00 63 130 00 15 5 10 500x400x200 24 EC 230 15 2 3 1 504 00 63 130 00 20 2x5 10 700x500x250 33 EC 230 20 3 4 1 662 00 125 157 00 25 5 2x10 700x500x250 34 EC 230 25 3 5 2 127 00 125 157 00 30 3x10 700x500x250 43 EC 230 30 3 3 2 389 00 125 157 00 37 5 7 5 3x10 700x500x250 44 EC 230 37 5 4 7 2 587 00 160 176 00 40 4x10 800x600x250 54 EC 230 40 4 4 2 788 00 160 176 00 45 3x15 800x600x250 D EC 230 45 3 3 2 972 00 160 176 00 50 10 2x20 800x600x250 65 EC 230 50 3 5 3 015 00 250 261 00 60 2x10 2x20 1000x600x400 81 ED 230 60 4 6 3 706 00 250 500 00 70 10 3x20 1000x600x400 84 ED 230 70 4 7 4 236 00 250 500 00 80 4x20 1000x600x400 90 ED 230 80 4 4 4 633 00 400 592 00 Series EL 100 5x20 1890x580x445 150 EL 230 100 5 5 6 336 00 400 764 00 110 10 5x20 1890x580x445 183 EL 230 110 6 11 6 852 00 400 764 00 120 6x20 1890x580x445 155 EL 230 120 6 6
152. retensi n corriente m xima y m nima del TC sobrecarga de los condensadores exceso de temperatura y exceso de arm nicos Suplemento por cambio a regulador premium Todas las bater as CYDESA pueden llevar el regulador que mida 3 fases para ello se debe sumar un suplemento por sustituci n del regulador al PVP del equipo est ndar Suplemento por sustituir el regulador Masing FPMp por el Masing Premium FPMp en una bater a CYDESA Suplemento FPIMp6 318 00 Suplemento FPMp12 424 00 CYDESA Expertos en energ a reactiva y arm nicos The new PFM controller Fomp Masing Premium added to the high performance of FPM Masing measurement display and performance on the three phases of power installation In facilities unbalanced with most single phase loads there Is a risk when measured just a phase that the reactive power compensation to fail The new Premium Masing regulator with three displays measures and displays three power factors and compensate based on the worst of the three CYDESA recommends using Premium Masing in installations where inductive 1phase loads are majority For installation of capacitor banks with Premium Masing regulators should foresee the installation of three current transformers so that the regulator can measure the three power factors CYDESA has two PF controller models Fomp Premium Masing 6 and 12 steps Features and measurements e Cos q inductive and capacitive e Three pha
153. rotocolo Como el Gobierno Espanol reasigna los derechos de emisi n entre los diversos sectores e industrias finalmente son las empresas las obligadas a su cumplimiento o a realizar el correspondiente desembolso En las previsiones del Plan Nacional de Derechos de Asignaci n PNA de Junio de 2006 se ha previsto la asignaci n para el sector el ctrico de 54 7 MtCO2 millones de toneladas de CO2 anuales contra 81 2 MtCO2 estimadas ambas cifras para el mismo periodo 2008 2012 Esto va a suponer un fuerte desembolso por parte de las Companias El ctricas en la adquisici n de derechos de emisi n as como un renovado inter s en reducir las emisiones y por ende las p rdidas en las redes y por tanto la necesidad de fomentar la compensaci n de la energ a reactiva como uno de los mecanismos m s claros de reducci n de las citadas p rdidas Reactive energy compensation contributes to struggle against global warming Losses on the electric network are important due to the high energetic cost They are measured through loss coefficients that enable to transfer the energy supplied to subscribers in their meter into energy supplied in generator terminals Since most of this losses depend on the square cos q graph it is clear to understand how much it is reduced by improving the Power Factor Abbreviated table for losses coefficients in the electric network en 2006 Coefficient 13 81 593 4 14 2 87 1 52 Type of power supply Low v
154. rrent circuit breaker on page 65 1 It is not possible to include a switch disconnecter without increasing the cubicle dimensions see next type 2 On request 50 CYDESA Expertos en energ a reactiva y arm nicos Price List 2014 Equipment Potencia Composicion Output Composition kvar 400V 100 2x25 1x50 125 25 2x50 150 3x50 175 25 3x50 200 2x25 3x50 225 25 4x50 250 2x25 4x50 275 25 5x50 300 6x50 325 25 2x50 2x100 350 50 3x100 375 25 50 3x100 400 2x50 3x100 425 25 2x50 3x100 450 50 4x100 475 25 50 4x100 500 2x50 4x100 525 25 2x50 4x100 550 50 5x100 575 25 50 5x100 600 6x100 600 2x50 5x100 625 25 2x50 5x100 650 50 6x100 675 25 50 6x100 700 2x50 6x100 kvar 440V 121 151 182 212 242 272 303 333 363 393 424 454 484 514 545 5 5 605 635 666 696 726 726 756 787 817 847 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 1 No es posible incorporar interruptor sin aumentar las dimensiones del armario ver tipo siguiente Bater as de condensadores estandar EDT EGT con contactores est ticos 400V 50Hz Caracter sticas e Caracter sticas generales en p g 44 e Con regulador de la serie Masing FPM ver p g 22 e Condensadores ver p g 8 e Interruptores est ticos ver p g 26 e Autotrafo de maniobra 400 230V e Acometida por la parte in
155. s 2014_Equipos Nuevas baterias de condensadores en cajas de doble aislamiento Basic y Prosec Plug amp Play New Capacitor banks in double isolated cabinets Basic and Prosec Plug Play Todas las bater as Basic y Prosec incluyen el transformador de intensidad CYDESA presenta una nueva gama de Bater as que cumplen un doble objetivo 1_Facilitar la instalaci n al prescindir de la conexi n a tierra y la protecci n diferencial 2 Proteger contra contactos directos e indirectos adem s de contra cortacircuitos y sobrecarga Las bater as Basic y Prosec llevan incorporado un interruptor de corte con enclavamiento mec nico y protecci n por fusibles montadas en armarios de doble aislamiento En la envolvente empleada en nuestras bater as Basic y Prosec el mando exterior del interruptor y la car tula cumplen con la protecci n contra contactos indirectos de clase Il seg n contempla la ITC BT 24 Por tanto no es de aplicaci n la puesta a tierra ni la protecci n diferencial lo cual permite simplificar la instalaci n Las Bater as Basic y Prosec est n fabricada seg n las normas CEl 61921 2003 EN 61921 Todas las bater as est n fabricadas en Espa a y todos sus componentes en la Uni n Europea Los condensadores tienen una tensi n asignada de 440V soportan 490V 8 horas cada 24h y tienen una esperanza de vida de 150 000 horas m s de 17 a os si trabajando 24h al d a CYDESA Expertos en energ a rea
156. s as mentioned in the following table Technical handbook Potencia Rated power Tension de primario Primary voltage MVA kV 25 20 36 10 16 45 66 20 30 40 Ejemplo Calcular la potencia de condensadores para compensar un transformador de 12MVA en vac o y con una carga del 80 de la nominal Potencia necesaria en vac o 0 85 x 12 000 100 102 kvar Potencia al 80 de P C 102 22 0 8 793kvar Condensadores monof sicos Pueden suministrarse unidades sueltas o bien bater as en simple o doble estrella con protecci n de desequilibrio incorporada Generalmente incorporan fusibles internos que junto con la protecci n por desequilibrio constituyen una protecci n segura contra perforaciones internas Externamente siempre deber acompa arse por protecciones complementarias Tensi n Potencia kV kvar 1a 24 50 1000 Condensadores trif sicos Pueden suministrarse con terminales al aire IPOO o bien protegidos IP55 No pueden incorporar fusibles internos Se pueden suministran con un sensor de presi n con contacto para actuar sobre un dispositivo externo de maniobra previsto para protecci n en caso de perforaci n interna junto con fusibles externos a prever por el instalador Tensi n Potencia kV kvar 1a 12 20 800 Corriente de vac o Tensi n de cc Unload current Impedance lo Uk 2 0 Es 7 1 1 8 1 0 8 0 9 9 0 8 9 0 7 10 0 6 11 0 6 12 Example Calculate the capacit
157. s can operate permanently at 415V and temporary up to 460V The power is always referred to 400V The higher rated series can operate permanently at 440V and temporary up to 490V The power is always referred to 400V Serie Reforzada Higher rated Series Potencia Seccionador Dimensiones Peso Tipo Precio Potencia Tipo Precio Output fusibles Dimensions Weight Type Price Output Type Price Switch Fuses H x A A1 x B kvar kvar A mm kg 400V 50Hz Ejecuci n Prismatica Prismatic Equipment 10 160 25 520x 260 300 x135 8 PhP 400 10 SF 494 00 15 160 40 520x 260 300 x135 8 5 PhP 400 15 SF 542 00 20 160 50 520x 260 300 x135 8 5 PhP 400 20 SF 571 00 20 PhP 400R 20 SF 614 00 25 160 63 520x 260 300 x135 9 PhP 400 25 SF 599 00 25 PhP 400R 25 SF 645 00 30 160 80 520x 260 300 x135 10 PhP 400 30 SF 683 00 30 PhP 400R 30 SF 734 00 35 160 80 520x 260 300 x135 11 PhP 400 35 SF 729 00 35 PhP 400R 35 SF 783 00 40 160 100 520x 260 300 x135 11 PhP 400 40 SF 804 00 40 PhP 400R 40 SF 863 00 50 160 125 520x 260 300 x135 12 PhP 400 50 SF 846 00 50 160 125 720x 260 300 x135 12 50 PhP 400R 50 SF 910 00 60 160 160 720x 260 300 x135 13 PhP 400 60 SF 968 00 60 PhP 400R 60 SF 1 041 00 70 160 160 720x 260 300 x135 15 PhP 400 70 SF 1 107 00 70 PhP 400R 70 SF 1 190 00 400V 50Hz Ejecuci n en caja mural Wall mounted equipment 80 160 160 800x600x250 35 EC 400 80 SF 1 641 00 80 EC 400R 80 SF 1 867 00 100 250 200 800x600x250 35 EC 400 100 SF 1 933 00 100 EC 400R
158. s tanto de baja como de alta tensi n Pero la soluci n viene de nuevo da la propia electr nica de potencia con los Filtros Activos de potencia capaces de eliminar los arm nicos y restituir la forma sinusoidal tanto a las ondas de corriente como de tensi n A continuaci n se detallan las principales caracter sticas de los FA p g 69 y en el Manual T cnico anexo pag 88 a 91 se detalla su principio de funcionamiento su dimensionado y su instalaci n Technological development has given us throughout history dramatic advances in all areas of human activity But we can not ignore some of the problems that this development implies A significant example of this duality is the one hand the enormous development of power electronics to join in the majority of industrial equipment among which stand out the variable speed drives for AC motors are known to spare advantages of drive no one discusses the energy saving and easy control you get with them Moreover and yet we can not ignore its adverse effects on the electric grid as distortion in the current and voltage waves and Is manifested by the appearance of harmonics in installations of low and high voltage But the solution is again given itself power electronics with active power filter able to eliminate harmonics and restore both sinusoidal waves of current and voltage Here are the main features of the AF p 68 and the Technical Manual Appendix p 88 91 shows its working principl
159. se conecta a la salida del transformador elegir un poder de corte Icu de 10 kA hasta 250 kVA uk gt 4 15kA hasta 400 kVA uk gt 4 25 kA hasta 630 kVA uk gt 4 25 kA hasta 1000 kVA uk 6 36 kA hasta 1250 kVA uk 6 2 series estandar y reforzada La serie estandar soporta 415V de forma permanente y una sobretensi n temporal hasta 460V La potencia est referida a 400V La serie reforzada soporta 440V de forma permanente y hasta 490V temporalmente La potencia siempre est referida a 400V Serie Est ndar Standard Series Dimensions Terminals 1 Terminales L1 L2 y L3 1 Terminals L1 L2 and L3 2 Terminal de tierra 2 Earthing terminal M8 hasta up to 400 20 SF M6hasta upto X 400 10 SF 400R 20 SF 400R 10 SF M10 hasta upto 400 30 SF M10hasta upto 400 70 SF 400R 30 SF 400R 70 SF M12 hasta upto 400 70 SF 400R 70 SF Prismatic capacitors with circuit breaker The PhP IA capacitors have an automatic circuit breaker with a high breaking capacity They represent the perfect solution to compensate single loads Technical data page 8 Painting colour RAL 7032 PhP RAL 7035 EC e Protection IP40 PhP IP30 EC Circuit breaker characteristics e f capacitor is connected to the transformer s supply chose among the next breaking capacities Icu 10 kA up to 250 kVA uk gt 4 15kAupto 400 kVA uk gt 4 25 kA up to 630 kVA uk gt 4 25 kA up to 1000
160. se voltages and currents e Power active reactive and apparent e THD in voltage and current e Working hours e Ambient temperature e 4 quadrant operation e Record maximum measured values of voltage current and temperature THD Alarms with a programmable relay Undercompensation overcompensation maximum and minimum TC current capacitor overload over temperature and over harmonics Supplement for replace to a premium capacitor All CYDESA capacitor banks can use regulator measuring 3 phases to this must be added a charge for replacing the regulator to the standard equipment list price Extra price to replace the regulator by the Masing Premium CYDESA FPMp in a capacitor bank FPMp6 supplement 318 00 FPMp12 supplement 424 00 Price List 2014 Capacitors Nuevo Regulador trifasico New Masing Premium Masing Premium 3 phase controller Caracteristicas Features Parametros Rango Ajuste por defecto Adjustable Range Adjustment by default Tension de alimentacion 220 440 V 3 fases phases A15 Supply Voltage 50 60 Hz Tension auxiliar 230 V Auxiliar Voltage Consumo Comsume 7 8 VA 5A L mites Limits 1 25 5 5 A Consumo Comsume 0 7W Corriente de medida Measuring current Factor de potencia Power Facior 0 75 ind 0 90 cap 0 90 Sensibilidad Tiempo de respuesta 5 600 S 30 Sensitivity Response Time Tiempo de reconexi n Restart time 16005 x Escal n fijo Programable Fixed step Programmable Comunic
161. su vez por simple ca da de tensi n llegan a deformar la tensi n en barras afectando por tanto a todos los dem s receptores de la instalaci n Estas ondas deformadas se descomponen para su an lisis en su componente fundamental a la frecuencia de red y arm nicas u ondas de frecuencia m ltiple de la red De entre los receptores generadores de arm nicos los m s usuales son Las fuentes de alimentaci n monof sicas Propias de los PC s entre otros y que generan arm nicos de orden 3 5 y 7 principalmente Los variadores de frecuencia para la regulaci n de velocidad de motores as ncronos usualmente de 6 pulsos y que generan arm nicos de orden 5 7 11 y 13 como m s significativos y de stos los m s apreciables el 5 y 7 Los sistemas de alimentaci n ininterrumpida o SAl s que en el caso de 6 pulsos generan los mismos arm nicos antes mencionados En resumen los denominados arm nicos caracter sticos son los de orden 3 5 7 11 y 13 y como significativos los de orden en edificios de oficinas en Industrias 3y5 5 y Las bater as de condensadores son uno de los elementos m s sensibles a los arm nicos absorbi ndolos f cilmente provocando una amplificaci n de los mismos y llegando incluso a producir problemas de resonancia Para evitar los inconvenientes mencionados en muchos casos es necesario conectar en serie con los condensadores reactancias de caracter sticas apropiadas con lo cual se dispone de un
162. t de Ll Facilities compensated by CYDESA Torre Iberdrola Bilbao CYDESA Experts in reactive energy and harmonics 33 Bater as de condensa Capacitor banks Gu a de selecci n de bater as Guide for Capacitor banks selection Nuevas bater as de condensadores en cajas de doble aislamiento Basic y Prosec Plug amp Play New Capacitor banks in double isolated cabinets Basic and ProsecPlug amp Play Bater as de condensadores estandar Standard capacitor banks Bater as de condensadores Premium para servicio extremo Premium automatic capacitor banks for exteme services Bater as de condensadores con filtros Capacitor banks with detuned filters Bater as fruto de la experiencia e innovaci n Capacitor banks based on experience and innovation Las bater as de condensadores CYDESA ofrecen la soluci n idonea para cada insalaci n Desde la sencillez seguridad y f cil instalaci n de la serie Basic y Prosec hasta la serie Premium destinadas a instalaci n con elevado grado de exigencia frente a duras condiciones de servicio Por otra parte la soluci n estandar tradicional de CYDESA ofrece la economia seguridad y fiabilidad fruto de casi cuatro d cadas de experiencia en la fabricaci n de bater as de condensaci n CYDESA capacitor banks offer the right solution for each Fixture Installation From the simplicity safety and ease of installation of the series and Prosec Basic to Premium series intended for installation wi
163. t the established limits or to pay for such allowances According to Allowance National Plan PNA in Spanish in June 2006 forecasts it is expected that Electrical Sector will be attributed 54 7MtCO2 per year against 81 2 MtCO2 estimated both numbers for the same period 2008 2012 Thus Electric Companies will have to pay great prices to buy emission allowances and it will be in their best interests to reduce emissions and in consequence losses on the network therefore it will be necessary to promote reactive energy compensation as one of the best mechanisms for reducing such losses CYDESA Experts in reactive energy and harmonics 75 76 C mo se traducen los kWh de energ a el ctrica en emisiones de CO2 Las centrales el ctricas excepto las hidr ulicas y nucleares utilizan combustibles que emiten gases de efecto invernadero medidos por el CO2 equivalente emitido As puede resumirse que para producir 1kWh se emiten 1Kg de CO2 en una central de carb n 750g en una de fuel y 300g en una de ciclo combinado La media en Espana teniendo en cuenta todos los tipos de centrales fue en 2006 de 429g de CO2 kWh es decir por cada kWh que consumimos emitimos a la atm sfera 429g de CO2 equivalente As una vivienda de tipo medio con un consumo de 500kWh mensuales emitir mensualmente 214 5Kg de CO2 a la atm sfera Para hacerse una mejor idea de la dimensi n del problema valga la siguiente comparaci n La emisi n
164. tall an equipment with filters might be suitable As a general rule the resonance frequency should keep so far from the mains existing harmonics CYDESA Experts in reactive energy and harmonics 87 88 Tradicionalmente para la compensaci n de arm nicos se han y siguen utiliz ndo los filtros pasivos compuestos por inductancias y condensadores en diversas configuraciones De ellas la m s utilizada es el filtro serie L C o filtro sintonizado a la frecuencia del arm nico que se desea compensar Si las cargas perturbadoras conectadas a la red dan lugar a la inyecci n de un espectro amplio de arm nicos la t cnica habitual es la de compensar los m s significativos con filtros sintonizados a sus respectivas frecuencias reduciendo por tanto la distorsi n arm nica a valores admisibles Sin embargo los filtros pasivos presentan varios inconvenientes Al incorporar condensadores inevitablemente aportan energ a reactiva capacitiva a la red que en casos de receptores sin consumo de energ a reactiva como sucede con los variadores de frecuencia para motores as ncronos resulta un inconveniente Si bien es factible la regulaci n autom tica con escalones de diversa potencia para ajustarse a compensaci n necesaria de arm nicos la estrategia de control resulta complicada ya que debe evitar la sobrecarga de unos escalones respecto a otros Provocan resonancias en la red que si bien se pueden alejar de los arm nicos caracter
165. te capacitor bank facilities disturbing loads AC variable speed D Potencia de la bater a kvar S Potencia del transformador kVA o Potencia de las cargas generadoras de arm nicos kVA O Capacitor bank output kvar S Transformer power kVA BN Power converters kVA Leer m s en la p gina siguiente gt gt Read more on the next page CYDESA Experts in reactive energy and harmonics 85 86 NNN Filtros de rechazo 189Hz Detuned filters 19952 Premium Premium O Potencia de la bater a kvar S Potencia del transformador kVA S Potencia de las cargas generadoras de CON arm nicos kVA Por debajo de la l nea de trazo continuo de la figura superior es posible instalar una bater a convencional con los condensadores a la tensi n de red Entre esta l nea y la de puntos es conveniente recurrir a equipos Premium para que soporten mejor la posible sobrecarga Por encima de la l nea a puntos debe recurrirse a equipos con filtros de rechazo Por ltimo para valores Scon S superiores al 50 recomendamos consultar ya que puede ser conveniente otro tipo de filtros Para S S lt 5 no cabe considerar ninguna limitaci n a la instalaci n de bater as convencionales ON Ejemplo 1 Instalaci n con un trafo de 400 kVA con una potencia de condensadores para compensaci n de 100 kvar Existen variadores de velocidad de 110 kVA de potencia total simult nea Q oy
166. th a high degree of demand against harsh conditions Moreover the traditional standard CYDESA solution offers the economy safety and reliability culmination of nearly four decades of experience in the manufacture of capacitor banks Lista de Precios 2014 Equipos Guia de seleccion de baterias Rango de Tension Denominaci n y caracter sticas Aplicaci n P gina potencias Voltage diferenciales Application Page Output 1 Differential characteristics range kvar V In double isolated cabinet class 5 25 440 BASIC BASIC Instalaciones de consumo reducido 39 e Un solo escal n con rel de reactiva peque as industrias o comercios Only one step with reactive relay Installations with low consumption e Magnetot rmico incorporado small industries and shops With circuit breaker e Trafo de intensidad incluido 2 CT Included 2 2 5 10 230 BASIC BASIC Instalaciones de consumo reducido 40 e Un solo escal n con rel de reactiva peque as industrias o comercios Only one step with reactive relay Installations with low consumption e Magnetot rmico incorporado small industries and shops With circuit breaker e Trafo de intensidad incluido 2 CT Included 2 12 240 440 PROSEC PROSEC En los casos en que se persigue la 41 42 e Regulador FPM max 6 escalones maxima facilidad y comodidad de FPM Regulator 6 steps max instalacion e Interruptor de corte de carga incorporado When an easy installation is a priority With switch disconn
167. thermore since electric current also flows through transformers there will also be an important reduction of losses on them For example going from a 0 75 to 0 9 cosine in a network supplied by 400 kVA transformer implies a loss saving of 7290 kWh per year at a rate of 0 10 per kWh would imply a 729 saving per year 1 Both concepts are the same in networks without harmonic distortion CYDESA Experts in reactive energy and harmonics 73 74 se aumenta la capacidad el ctrica de la instalaci n Tanto las lineas como los transformadores estan limitados por la corriente que circula y al ser la tension practicamente constante lo estan por el producto U o potencia aparente S Pero de una misma potencia aparente podemos sacar una potencia til o activa P S cos As en una instalaci n con un transformador de 400 kVA y cos q 0 75 s lo se podr n obtener 300kW mientras que si mejora el cos y a la unidad se podr llegar a obtener 400kW Manual t cnico Increase in the electrical installation capacity Lines as well as transformers are limited by the flowing current and since voltage is virtually constant they are also limited by the product U or apparent power But it from a same apparent power it is possible to obtain a useful or active power P S cos Then in a 400 kVA installation with a cos 0 75 only 300 kW will be obtained whereas if cos y is improved until reaching the unit
168. tico con seccionador y fusibles Prismatic capacitor with fuse switch disconnector CYDESA Expertos en energ a reactiva y arm nicos EC 400 80 1A 36 2 832 00 EC 400 100 1A 36 3 252 00 EC 400 120 1A 36 3 373 00 80 ECA00R 80 A 36 3 402 00 100 EC 400R 100 IA 36 3 528 00 120 EC 400R 120 1A 36 3 729 00 values corresponding to the higher rated equipments Dimensions Terminals 1 Terminales L1 L2 y L3 1 Terminals L1 L2 and L3 M8 hasta up to 400 20 IA 400R 20 14 M10 hasta up to 400 30 A 400R 30 1A M12 hasta up to 400 75 IA 400R 75 IA Condensador con interruptor autom tico con 10kA de poder de corte Prismatic capacitors with 10 kA breaking capacity circuit breaker 2 Terminal de tierra 2 Earthing terminal 400 10 A 400R 10 IA M6 hasta up to M10 hasta up to 400 75 IA 400R 75 IA Condensador con interruptor autom tico con 25kA de poder de corte Prismatic capacitors with 25 kA breaking capacity circuit breaker Price List 2014 Capacitors Capacitors with contactor and fuses Condensadores con contactor m s fusibles The capacitors with contactor and fuses represent a fast and easy solution to Extend automatic equipments for the power factor correction Compensate single loads when a direct connection to the terminals is not recommended for example motors Los condensadores con contactor fusibles resultan una soluci n sencilla y r pida para Ampliar equipos de correc
169. tually all areas of industry and services including Pumping stations Where the use of ASD s make difficult the use of passive filters for your input capacitive power to the network Office buildings hospitals and hotels Where the third harmonic compensation avoiding overhead conductor is one of the important requirements Welding applications Where reactive and harmonic requires a high speed of response Here ECOsine Active filter has a dynamic response time as only 300 micro seconds Elevators Which is needed quickly and above all a great switching frequency is not feasible compensation systems with contactors In renewable energy Such as wind farms and solar plants which requires a power quality delivered to the grid difficult to achieve by other means etm y E CYDESA Experts in reactive energy and harmonics 91 92 Manual t cnico Condensadores de media tensi n Un gt 1000 V Medium voltage capacitors Un gt 1000 V Los condensadores de media tension se fabrican a base de bobinas compuestas por folios de aluminio entre folios de polipropileno Estas bobinas se introducen en un contenedor de chapa de acero que se rellena con un aceite no PCB Los condensadores monofasicos se fabrican hasta aproximadamente 1000kvar en ejecuci n interior o intemperie y hasta una tensi n nominal de 24kV Los condensadores trif sicos se fabrican hasta una potencia de 800kvar y hasta 12kV de tensi n nominal EN 608
170. ueden incorporarse fusibles internos que junto con unas protecciones de desequilibrio para montajes en doble estrella constituye una protecci n muy segura en caso de perforaciones internas Esta protecci n deber completarse con otras de cortocircuito sobrecarga de corriente sobretensi n y subtensi n En unidades trif sicas no son operativos los fusibles internos y no es posible una protecci n por desequilibrio por lo que los fusibles externos resultan imprescindibles por su rapidez de actuaci n frente a otros dispositivos como por ejemplo interruptores autom ticos Como protecci n complementaria frente a perforaciones de bobinas que generan gases y por tanto una sobrepresi n interna se incorpora el dispositivo D que comprende un sensor de presi n y un contacto conmutado que permite senalizar y actuar sobre un dispositivo de corte contactor o interruptor Deber preverse adem s las correspondientes protecciones de sobretensi n y subtensi n tele Condensador monofasico con fusibles internos Single phase capacitor with internal fuses Riesgo de incendio o explosion En los condensadores de M T no es posible descartar totalmente el riesgo de explosi n y en consecuencia el incendio del aceite impregrante Por estos motivos deber elegirse un lugar de ubicaci n de los condensadores que respete las distancias de seguridad rutas de escape etc Protecci n de desequilibrio para montaje en doble estrella Unbalan
171. uip ment An RCCB type A with an operating current of 300mA is used Type A is protected against unwanted tripping Price List 2014 Equipment Baterias de condensadores estandar ED 400V 50Hz Caracteristicas e Caracteristicas generales en pag 44 e Fijaci n sobre suelo e Con regulador FPM ver p g 22 e Condensadores ver p g 8 e Contactores con resistencias previas para limitaci n de la corriente de conexi n e Autotrafo de maniobra 400 230V e Acometida por la parte inferior e Ventilaci n forzada para 200kvar e Protecci n diferencial opcional Standard capacitor bank ED 400V 50Hz Technical data e Technical data on page 44 e Floor mounted e With FPM controller see page 22 e Capacitors see page 8 e Contactors with previous resistors to damp the switch on current e Autotrans for aux voltage 400 230V e Incoming at the bottom e Forced cooling for 200kvar e Optional residual current protection 400V 50Hz Potencia Composici n Dimensiones Peso Tipo Precio Suplemento Output Composition Dimensions Weight Type Price interruptor de corte HxAxB en carga Extra price for switch disconnector Calibre Precio Size Price kvar 400V kvar 440V mm kg A 112 5 12 5 2x25 1x50 136 1000x600x400 75 ED 400 112 5 4 9 3 145 00 250 500 00 125 25 2x50 151 1000x600x400 US ED 400 125 3 5 3 369 00 250 500 00 150 2x25 2x50 182 1000x600x400 79 ED 400 150 4 6 3 594 00 400 592
172. urity solutions for power factor correction In this short space trust help achieve this purpose 72 Energia reactiva Reactive energy La compensacion de energia reactiva una inversion de maxima rentabilidad y que contribuye a la lucha contra el cambio clim tico Qu es la energ a reactiva Para accionar una m quina es necesario un motor y en consecuencia un consumo de energ a el ctrica si se trata un motor el ctrico A esta energ a en Electrotecnia se la conoce como energ a activa Pero para que un motor funcione hace falta un campo magn tico y para generarlo es necesaria una corriente denominada magnetizante o reactiva la cual da lugar a la energ a reactiva 1 que para generarla no es necesaria ninguna potencia til y por tanto no consume energ a primaria m s que la necesaria para cubrir las p rdidas que produce al circular por la red el ctrica Por compensaci n de energ a reactiva se entiende la reducci n o eliminaci n de esa circulaci n ya que su consumo por motores u otras m quinas y equipos el ctricos es inevitable como ya se ha mencionado En Electrotecnia se barajan tres conceptos de potencia activa P reactiva O y aparente S cuya relaci n entre ellas es s2 P2402 lo que sugiere su representaci n mediante un tri ngulo rect ngulo de portencias S o P Como la diferencia entre potencias y energias es el tiempo horas de servicio lo expuesto sirve igualmente pa
173. ut s Secci n m nima ae 15 21 6 4 25 mm2 30 32 40 32 20 29 10 6 Minimum cross section 90 40 63 40 25 36 10 10 25 mm2 63 50 63 50 30 43 16 10 80 60 80 63 35 51 25 16 80 70 100 80 40 58 25 16 100 80 100 80 50 72 35 25 1x25 125 100 125 100 60 87 50 35 1x35 160 120 125 125 70 101 70 50 1x35 160 140 160 160 75 108 70 50 1x50 160 150 160 160 80 116 70 50 1x50 250 160 200 160 387 5 126 70 1x70 250 175 200 200 100 145 70 1x70 250 200 250 200 125 181 95 1x95 315 250 315 250 150 217 150 1x120 400 300 400 315 175 253 185 1x150 400 350 400 355 200 289 240 1x185 500 400 630 400 225 325 240 1x240 500 455 630 425 250 361 1x240 630 505 630 500 275 397 1x300 or 2x120 2 630 555 630 550 300 434 2x150 2 800 605 630 630 325 470 2x150 2 800 660 800 630 350 506 2x185 2 800 710 800 800 375 542 2x185 2 800 760 800 800 400 578 2x240 2 1000 810 1000 800 425 613 2x240 2 1000 860 1000 800 450 649 2x240 2 1000 910 1000 1000 475 685 2x300 or 3x185 2 1000 960 1000 1000 500 722 2x300 or 3x185 2 1250 1010 1250 1000 525 758 3x185 2 1250 1060 1250 1000 550 794 3x240 2 1250 1110 1250 1250 575 830 3x240 2 1250 1160 1250 1250 600 867 3x240 or 4x185 2 1250 1210 1250 1250 650 939 3x300 or 4x185 2 1600 1315 1600 1250 700 1011 3x300 or 4x240 2 1600 1415 1600 750 1083 5x185 2 1600 1520 1600 800 1155 5x185 2 2000 1620 850 1227 5x240 2 2000 1720 900 1299 5x240 2 2000 1820 950 1371 6x240 2 2000 192
174. vervoltages Un capacitor rated voltage Current overload In capacitor rated current Voltage test between terminals between terminal and casing Ambient temperature Cylindrical IPOO Cylindrical IP54 and Prismatic Installation conditions Humidity Altitude Cooling Position EN 60831 1 and 2 Metallized polypropylene film non PCB 230 V 400 V 440 V 525 V 690 V and 1050V 50 and 60 Hz Cylindrical IPOO up to 25 kvar 400 V 30 kvar 440 V Cylindrical IP54 up to 25 kvar 400V Prismatic IP43 up to 100 kvar 400 V lt 0 25 W kvar with the cylindrical type lt 0 5 W kvar with the prismatic type including cable losses 5 measured at 20 C of ambient temperature Un 10 up tp 8h per day Un 15 up to 30 min per day Un 20 up to 5 min Un 30 up to 1 min In 30 2 15 Un AC 2 seconds 4800 VAC 2 seconds 25 D max 55 C average 24h 45 C 2b C max 50 C average 24h 40 C Max 9596 Max 2000m Natural Vertical preferable Price List 2014 Capacitors Low voltage Capacitors ESTAprop Technical data Esperanza de vida gt 150 000 horas de servicio Corriente de conexion Hasta 300 x ln se recomienda reducir a lt 100 x In mediante el empleo de contactores con resistencias previas Desconectador de sobrepresion Proteccion el ctrica Protecci n mec nica Tubular IPOO IP20 con cubrebornes o IP54 Prism tica I
175. x600 343 EG 400 575 12 23 2000x1200x600 347 EG 400 600 12 12 2000x1200x600 356 EG 400 625 8 25 2000x1200x600 359 EG 400 650 7 13 2000x1200x600 363 EG 400 675 8 27 2000x1200x600 366 EG 400 700 8 14 2000x1200x600 369 EG 400 725 9 29 2000x1200x600 373 EG 400 750 8 15 2000x1200x600 376 EG 400 775 9 31 2000x1200x600 380 EG 400 800 9 16 2100x1200x600 398 EG 400 850 9 17 2100x1200x600 405 EG 400 900 10 18 2100x1200x600 412 EG 400 950 10 19 2100x1200x600 419 EG 400 1000 11 20 Precio Suplemento Price interruptor de corte en carga Extra price for switch disconnector Calibre Precio Size Price A 10 808 00 1000 1 959 00 10 851 00 1000 1 959 00 11 449 00 1 1 11 834 00 1000 2 402 00 11 892 00 1 1 12 760 00 1000 2 402 00 12 052 00 1 1 12 804 00 1000 2 402 00 13 700 00 1000 2 402 00 14 058 00 1250 2 708 00 14 165 00 1250 2 708 00 14 712 00 1250 2 708 00 14 938 00 1250 2 708 00 15 490 00 1250 2 708 00 15 535 00 1250 2 708 00 16 370 00 1600 2 980 00 16 586 00 1600 2 980 00 17 461 00 1600 2 980 00 17 681 00 1600 2 980 00 18 143 00 1600 2 980 00 18 713 00 1600 2 980 00 19 113 00 1600 2 980 00 19 303 00 2 2 21 837 00 2 2 22 640 00 2 2 24 144 00 2 2 24 702 00 2 2 Otros suplementos e Para interruptor autom tico y diferencial ver p g 65 1 No es posible incorporar interruptor sin aumentar las dimensiones del armario ver tipo siguiente 2 Bajo demanda Other extra prices e Residual cu
176. y Cable Power losses Ap AP P 22xF xR P c a monophasic Ap AP P Z3xP x R P c a phase RL can be calculated by the expression RL 2p xL S with Peu 17 24 ohm x mm km Pa 28 26 ohm x mm km Connection of capacitors In parallel C C C C IL x bul In series En Bor x Wh U Us 1 C 1 C 1 C YE U U U U In triangle or star Assuming equal powers Q 20 C 3C Assuming equal capacities C C 0 30 CYDESA Experts in reactive energy and harmonics 109 110 Sobretensiones Los condensadores conectados a una red inductiva producen un aumento de tensi n efecto utilizado para regulaci n de tensi n en redes el ctricas El condensador O de la figura se conecta a un punto de la red con una potencia de cortocircuito S dando lugar a un incremento de tension AU 100 K Este fen meno se da con frecuencia en transformadores con carga capacitiva Caso t pico de trabajo en vac o y con condensadores conectados El condensador O produce un aumento de tensi n en barras en una red inductiva de react ncia de cortocrcuito X Variacion de la potencia reactiva til de un condensador en funci n de la tensi n soportada Los dos par metros m s significativos que definen una bater a de condensadores son potencia reactiva asignada Or y tensi n asignada Ur la potencia reactiva se suele dar en kilovoltio amperios reactivos kvar y la tensi
177. y and harmonics 113 Anotaciones 114 CYDESA Expertos en energ a reactiva y arm nicos Construcciones y Distribuciones El ctricas S A Pol Ind Sant Antoni Parcela 2 Nave A 08620 Sant Vicenc dels Horts Barcelona Espa a Tel 34 936 565 950 Fax 34 936 769 745 www cydesa com cydesa cydesa com e c i Para obtener m s informaci n sobre nuestros nN productos visite nuestra web For further product information visit our website www cydesa com