1. VC6300 Volt Doctor 7 24 06 10 33 AM Page 1 VC6300 SPERRY INSTRUMENTS Vo i Dolo 0 ails Voltage and Continuity Tester e Read this owners manual thoroughly before use and save 2150 Joshua s Path Suite 302 Hauppauge NY 11788 1 800 645 5398 e www sperryinstruments com 1 0 METER FUNCTIONS 1 DC Polarity Indicators 2 AC DC Voltage Scale 3 Probe Holders and Storage 4 Continuity Indicator 5 Battery Compartment 2 0 READ FIRST IMPORTANT SAFETY INFORMATION A N MN Read this operators manual thoroughly before using this meter This manual is intended to provide basic information regarding this meter and to describe common test procedures which can be made with this unit Many types of appliance machinery and other electrical circuit measurements are not addressed in this manual and should be handled by experienced service technicians AA WARNING Use extreme caution when using this meter Improper use of this meter can result in severe damage to property severe personal injury or death Follow all instructions and suggestions in this operators manual as well as observing normal electrical safety precautions Do not use this meter if you are unfamiliar with electrical circuits and proper test procedures SAFETY WARNINGS This instrument has been designed manufactured and tested according to IEC61010 Safety requirements for Electronic Measuring apparatus and delivered in the best con
2. Al usar los electrodos de prueba el probador se activar autom ticamente al conectarse al voltaje de CA o CC El probador seleccionar autom ticamente la funci n correcta Fig 1 di UE Fig 1 Fig 2 4 1 Prueba de la continuidad Toque con las puntas de los electrodos de prueba los puntos donde se necesita realizar las pruebas Si la resistencia es inferior a 50 ohmios se iluminar la luz de continuidad arriba Fig 2 4 2 2 Medici n de los niveles de voltaje de CC Mida el voltaje tocando el circuito con las puntas de los electrodos donde se necesite el valor del voltaje Si el electrodo de prueba amarillo est en el contacto positivo se iluminar la luz VCC Si el electrodo de prueba amarillo est en el contacto negativo se iluminar la luz VCC Fig 3 Lea el nivel de voltaje desde la escala de voltaje de CC 4 3 Medici n de los niveles de Fia 3 voltaje de CA 9 Mida el voltaje tocando el circuito con las puntas de los electrodos donde se necesite el valor del voltaje Se iluminaran ambos indicadores de polaridad para indicar el voltaje de CA Fig 4 Lea el nivel desde la escala de voltaje de CA No importa la polaridad de los electrodos para las mediciones de voltaje de CA 5 0 CAMBIO DE LAS BATER AS No abra la caja del probador mientras lo use 1 Cuando el voltaje de la bater a baje del rango operativo adecuado ya no fu
3. e Altitud de 2000 m o menor La temperatura operativa adecuada est entre 32 F 104 F 0 C 40 C e Este instrumento no es a prueba de polvo ni agua Mant ngalo alejado del polvo y del agua e Cuando el instrumento no vaya a estar en uso por un tiempo largo p ngalo en almacenamiento despu s de extraerle las bater as e Limpieza Use un pa o sumergido en agua o detergente neutro para limpiar el instrumento No use abrasivos ni solventes de lo contrario el instrumento puede danarse deformarse o decolorarse 3 0 ESPECIFICACIONES Voltaje de CC 120 600 Voltios Voltaje de CA 120 600 Voltios Frecuencia de voltaje de CA 50 60 Hz S lo servicio intermitente Encendido 15 segundos apagado 240 segundos Ambiente operativo 32 F 104 F 0 C 40 C 80 de humedad relativa max 50 de humedad relativa sobre 31 C Para Se al sonora Luz probar gt las sondas deslice hacia abajo desde arriba No hay reacci n ee Altitud de hasta 2000 metros Uso en interiores Dos Temperatura de almacenamiento 14 F manos 140 F 10 C 60 C Baterias 2 pilas de boton de 1 5 Voltios CAT Ill 600V 4 0 OPERACI N Este medidor se ha dise ado con portasondas para permitir m xima versatilidad y realizar pruebas usando una sola mano Consulte los esquemas de la Fig 1 para ver las configuraciones comunes Funcionamiento autom tico
4. 10 Requisitos de seguridad para aparatos electr nicos de medici n y se entrega en el mejor estado despu s de pasar la inspecci n Este manual de instrucciones contiene advertencias y reglas de seguridad que el usuario debe observar para garantizar el funcionamiento seguro del instrumento y mantener su estado sin presentar peligro Por lo tanto lea estas instrucciones operativas antes de usar el instrumento pra verrencial Conserve a mano el manual para poder usarlo a modo de referencia r pida siempre que sea necesario e El instrumento debe usarse solamente en las aplicaciones contempladas e Entienda y siga todas las instrucciones de seguridad contenidas en el manual e Es esencial que se respeten las instrucciones anteriores e Si no se siguen las instrucciones anteriores puede causar lesiones da o al instrumento y o da o al equipo a prueba N Nela PELIGRO S reserva para condiciones y acciones que pueden causar lesiones serias o fatales AiPrEcAUCION se reserva para condiciones y acciones que pueden causar lesiones o da o al instrumento PELIGRO Nunca tome medidas en un circuito donde exista voltaje sobre 600V de CA e No intente tomar medidas en la presencia de gases inflamables De lo contrario el uso del instrumento puede causar chispas lo cual puede ocasionar una explosi n e Este probador est dise ado s lo para servicio intermitente encendido 15 segundos apagado 240 segund
5. INSTRUMENTS Voltage Doctor Probador de voltaje y continuidad e Lea este manual del propietario totalmente antes del uso y ahorre 12150 Joshua s Path Suite 302 Hauppauge NY 11788 1 800 645 5398 e www sperryinstruments com 1 0 FUNCIONES DEL MEDIDOR 1 Indicadores de polaridad de CC 2 Escala de voltaje de CA CC 3 Portasondas y almacenamiento 4 Indicador de continuidad 5 Compartimiento de bater a 2 0 LEER PRIMERO INFORMACI N IMPORTANTE DE SEGURIDAD A N Lea este manual del operador totalmente antes de usar este medidor Este manual est destinado a brindar informaci n b sica referente a este medidor y a describir procedimientos comunes de prueba que pueden realizarse con esta unidad Muchos tipos de mediciones de circuitos el ctricos artefactos y maquinarias no se describen en este manual y deben realizarlas los t cnicos de servicio experimentados overenej Tenga sumo cuidado al utilizar este medidor El uso indebido de este medidor puede producir graves da os materiales adem s de lesiones f sicas serias o fatales Siga todas las instrucciones y sugerencias en este manual del operador y observe tambi n las precauciones de seguridad normales con la electricidad No use este medidor si no est familiarizado con los circuitos el ctricos y los procedimientos correctos de prueba ADVERTENCIAS DE SEGURIDAD Este instrumento ha sido dise ado fabricado y probado conforme a IEC610
6. dition after passing inspection This instruction manual contains warnings and safety rules which must be observed by the user to ensure safe operation of the instrument and retain it in safe condition Therefore read through these operating instructions before using the instrument AA WARNING Keep the manual at hand to enable quick reference whenever necessary e The instrument is to be used only in its intended applications e Understand and follow all the safety instructions contained in the manual e It is essential that the above instructions are adhered to e Failure to follow the above instructions may cause injury instrument damage and or damage to equipment under test ADANGER is reserved for conditions and actions that can cause serious or fatal injury N Nela AcautTion is reserved for conditions and actions that can cause injury or instrument damage Never make measurement on a circuit in which voltage over AC 600 V exists e Do not attempt to take measurements in the presence of flammable gasses Otherwise the use of the instrument may cause sparking which can lead to an explosion e This tester is designed for intermittent duty only On 15 seconds Off 240 seconds It should only take several seconds to note a voltage indication If the reading is maintained longer than 15 seconds damage to the unit may occur AA WARNING Never attempt to use the instrument if its surface or your hand is
7. he voltage by touching the test lead tips to the circuit where the value of voltage is needed If the yellow test lead is on the positive contact the VDC light will illuminate If the yellow test lead is on the negative contact the VDC light will illuminate Fig 3 Read the voltage level from the DC voltage scale 4 3 Measuring AC Voltage Levels Measure the voltage by touching the test lead tips to the circuit where the value of voltage is needed Both polarity indicators will illuminate to indicate AC Voltage Fig 4 Read the level from the AC voltage scale The polarity of the leads does not matter Fig 2 Yellow for AC voltage measurements Fig 3 5 0 CHANGING THE BATTERIES Do not open tester case while using the tester 1 When the battery voltage drops below proper operating range the tester will no longer function 2 Slide rubber boot at the bottom of the tester out of the way and remove the screw to access the battery compartment 3 Slide the bottom out and replace with 2 1 5 Volt button cell batteries LR44 SR44 A76 G13 AG13 GP76A 257 D357 V13GA 4 Replace battery door screw and rubber boot to original positions 5 Test on known live circuit to verify proper operation Also test continuity function by touching the two leads together Refer to 1 0 Meter Functions Fig 4 VC6300 Volt Doctor 7 24 06 10 33 AM Page 2 SPERRY an
8. lace it in storage after removing the batteries e Cleaning Use a cloth dipped in water or neutral detergent for cleaning the instrument Do not use abrasives or solvents otherwise instrument may get damaged deformed or discolored 3 0 SPECIFICATIONS DC Voltage 120 600 Volts AC Voltage 120 600 Volts AC Voltage Frequency 50 60 Hz Intermittent Duty Only On 15 seconds Off 240 seconds Operation Environment 32 F 104 F 0 C 40 C 80 RH Max 50 RH above 31 C Altitude up to 2000 meters Indoor use Storage Temperature 14 F 140 F 10 C 60 C Batteries 2 1 5 V button cells For testing probes slide down from top EE eee CAT IlI 600V Two 4 0 OPERATION Hand This meter is designed with probe holders to allow for maximum versatility and single hand testing Refer to the drawings in Fig 1 for common setups Automatic Operation When using the test leads the tester will automatically activate when connected to AC or DC voltage The tester will automatically select the proper function 4 1 Testing Continuity Touch the tip of the test leads to the points where tests need to be made If the resistance is below 50 ohms the continuity light at the top will illuminate Fig 2 Fig 1 Mle UE Beeper Light 9 No Reaction Fig 1 4 2 Measuring DC Voltage Levels Measure t
9. ncionar el probador 2 Deslice el manguito de caucho en la parte inferior del probador para que no estorbe y quite el tornillo para acceder al compartimiento de la bater a 3 Deslice la parte inferior hacia afuera y Fia 4 cambie por 2 bater as de bot n de 1 5 Voltios LR44 SR44 A76 G13 AG13 GP76A 257 D357 V13GA 4 Vuelva a colocar la puerta de las bater as y el manguito de caucho en sus posiciones originales 5 Pruebe con un circuito energizado conocido para verificar que funcione bien Pruebe tambi n la funci n de continuidad tocando juntos los dos electrodos Consulte 1 0 Funciones del medidor
10. os Debe tardar s lo unos segundos anotar una indicaci n de voltaje Si se mantiene la lectura m s de 15 segundos puede da arse la unidad ADVERTENCIA Nunca intente usar el instrumento si est mojada la superficie o la mano e No supere la entrada m xima permisible de cualquier rango de medici n e El instrumento debe usarse solamente en las aplicaciones o condiciones contempladas De lo contrario las funciones de seguridad con las cuales se ha equipado el instrumento quedan inoperantes y puede causarse da o al instrumento o lesiones f sicas serias Nunca intente tomar medidas si se encuentra alguna condici n anormal tal como la caja rota o piezas met licas expuestas en el instrumento e No sustituya piezas ni haga modificaciones al instrumento Para reparar o recalibrar el instrumento devu lvalo a su distribuidor local donde lo compr e Desconecte todos los cordones y cables del objeto a prueba antes de abrir la tapa de la bater a para cambiar la bater a e Verifique el funcionamiento correcto en una fuente conocida antes de usar o de actuar bas ndose en lo que indic el instrumento A PRECAUCION Use el equipo protector personal adecuado como guantes aisladores botas aisladoras y anteojos de seguridad e No exponga el instrumento al sol directo a alta temperatura ni humedad o ca da de roc o e Si se usa el medidor en reas con campos magn ticos altos puede ocasionar lecturas imprecisas
11. wet e Do not exceed the maximum allowable input of any measuring range e Never open the battery cover during a measurement e The instrument is to be used only in its intended applications or conditions Otherwise safety functions equipped with the instrument don t work and instrument damage or serious personal injury may be caused AA WARNING Never attempt to make measurements if any abnormal conditions such as broken case or exposed metal parts are found on the instrument e Do not install substitute parts or make any modification to the instrument For repair or re calibration return the instrument to your local distributor from where it was purchased e Disconnect all the cords and cables from the object under test before opening the battery cover for battery replacement e Verify proper operation on a known source before use or taking action as a result of the indication of the instrument Use appropriate personal protective equipment such as insulating gloves insulating boots and safety glasses e Do not expose the instrument to the direct sun high temperature and humidity or dewfall e Using the meter in areas with high magnetic fields can result in inaccurate readings e Altitude 2000m or less Appropriate operating temperature is within 32 F 104 F 0 C 40 C e This instrument isn t dust and water proofed Keep away from dust and water e When the instrument will not be in use for a long period p