OneTouch® Verio™ Test Strip Insert US English/Spanish
Contents
1. e ao un 2 PFo_ _ E O 40 a 0 S bi zn o E ao E s AAA sa gt ZE 0 gt In vitro diagnostic For self testing IMPORTANT Please read this insert and your Owner s Booklet before using The Owner s Booklet has full instructions for blood glucose and control solution testing Do Not use new test strips if the vial is open or damaged in any way This could lead to error messages or inaccurate blood glucose results Contact LifeScan Customer Service right away at 1 888 567 3003 English 7 days a week 8 a m 10 p m Eastern Time For assistance outside of these hours please contact your health care professional if you have questions about your test strips test results or these instructions IMPORTANT SAFETY INSTRUCTIONS This meter and lancing device are intended to be used by a single person and should not be shared even with a family member After use and exposure to blood all parts of this kit are considered biohazardous A used kit can potentially transmit infectious diseases even after you have performed cleaning and disinfection Refer to your Owner s Booklet for important information about cleaning and disinfecting your meter lancing device and caps Intended Use The OneTouch Verio Test Strips are used with the OneTouch Verio Family of Blood Glucose Monitoring Systems OneTouch Verio IQ for the quantitative measurement of glucose sugar in fresh capillary who
2. as de la semana de 8 a m a 10 p m hora del este para asistencia fuera de este horario comun quese con su profesional del cuidado de la salud si tiene preguntas sobre las tiras reactivas los resultados de las pruebas o estas instrucciones INSTRUCCIONES IMPORTANTES DE SEGURIDAD Se recomienda que un solo persona utilice este medidor y su dispositivo de punci n y no debe compartirse ni siquiera por un miembro de su familia Luego de su uso y exposici n a la sangre todas las partes de este kit se consideran de riesgo biol gico Es posible que un kit usado pueda transmitir enfermedades infecciosas incluso despu s de su limpieza y desinfecci n Consulte su Manual de propietario para conocer informaci n importante sobre como limpiar y desinfectar su medidor el dispositivo de punci n y las tapas Uso recomendado Las tiras reactivas OneTouch Verio se utilizan con la familia de sistemas de supervisi n de glucosa en la sangre OneTouch Verio OneTouch Verio IQ para realizar una medici n cuantitativa de la glucosa az car en la sangre completa capilar reci n extra da de la punta de un dedo La familia de sistemas de supervisi n de glucosa en la sangre OneTouch Verio est dise ada para ser utilizada por un solo paciente y no debe utilizarse para realizar pruebas en varios pacientes Consulte el Manual del propietario que acompa an a su medidor para el Uso recomendado del sistema completo Almacenamien
3. del medidor no son adecuadas para pruebas en lugares alternativos Los resultados de muestras extra das del antebrazo o de la palma de la mano podr an ser diferentes de los obtenidos con muestras de la punta del dedo Esto se debe a diferencias normales en el flujo sangu neo No refleja la precisi n del sistema Consulte con el profesional del cuidado de la salud que lo atiende antes de utilizar el antebrazo o la palma de la mano para extraer muestras Las diferencias en la lectura de la glucosa en la sangre entre la punta del dedo y otros lugares de punci n podr an ocurrir despu s de comer tomar medicamentos de insulina o hacer ejercicio Esto se debe a que los niveles de az car en la sangre cambian m s r pidamente en la punta del dedo Las pruebas en lugares alternativos AST por sus siglas en ingl s no se deben utilizar para calibrar monitores de glucosa continuos CGM por sus siglas en ingl s o para calcular la dosis de insulina Las pruebas en sitios alternativos s lo deben realizarse durante estados estacionarios cuando la glucosa no cambia r pidamente Tenga en cuenta que el medidor OneTouch Verio IQ no est indicado para hacer pruebas en lugares alternativos Principio de la prueba La familia de medidores OneTouch Verio est n calibrados con plasma a fin de facilitar la comparaci n entre resultados y m todos de laboratorio La glucosa de la muestra de sangre se mezcla con sustancias qu micas especiales c
4. el cido asc rbico vitamina C y el cido rico cuando se producen en concentraciones terap uticas altas o normales altas en la sangre no afectan los resultados de manera significativa No obstante las concentraciones anormalmente altas en la sangre pueden proporcionar resultados bajos inexactos Los niveles de Tolazamida de hasta 7 5 mg dL 3 veces m s de lo encontrado en altos niveles terap uticos no afectan los resultados de glucosa en la sangre e Siel paciente tiene deshidrataci n intensa se encuentra en estado de shock o en estado hiperosmolar con o sin cetosis se pueden producir resultados bajos falsos Nose deben realizar pruebas con medidores de la glucosa en sangre en pacientes que est n gravemente enfermos e Muestras lip micas los niveles de colesterol de hasta 700 mg dL y de triglic ridos de hasta 3 000 mg dL no afectan los resultados No se han evaluado muestras de pacientes extremadamente lip micos y no se recomienda analizar estas muestras con la familia de medidores OneTouch Verio ZA PRECAUCI N los sistema de supervisi n de glucosa en la sangre de la familia OneTouch Verio no deben utilizarse dentro de las 24 horas de que el paciente haya recibido una prueba de absorci n de D xilosa ya que podr a arrojar resultados altos inexactos Limitaciones de lugares alternativos Consulte con el Manual del propietario que vino con su medidor para el uso recomendado del sistema completo Algunos sistemas
5. y cantidad de resultados de medidor que coinciden con la prueba de laboratorio Dentro de Dentro de Dentro de 5 mg dL 10 mg dL 15 mg dL 88 2 100 0 100 0 45 51 51 51 51 51 Resultados de precisi n del sistema usando concentraciones de glucosa 275 mg dL Porcentaje y cantidad de resultados de medidor que coinciden con la prueba de laboratorio Dentro de Dentro de Dentro de Dentro de 15 10 15 20 71 1 94 8 98 0 100 177 249 236 249 244 249 249 249 Resultados de precisi n del sistema a lo largo de todo el intervalo de glucosa Porcentaje y cantidad de resultados de medidor que coinciden con la prueba de laboratorio Dentro de 15 mg dL o 20 100 300 300 objetivo sugerido por los expertos en diabetes Estad sticas de regresi n Por lo tanto 100 de los resultados totales obtenidos con el sistema OneTouch Verio IQ lograron el Las pruebas de cada muestra fueron realizadas por duplicado en cada uno de los tres lotes de tiras reactivas Los resultados de la comparaci n entre el sistema OneTouch Verio IQ y los m todos de laboratorio son positivos Cantidad de Cantidad de Pendiente Intersecci n sujetos pruebas mg dL 100 300 0 95 4 81 95 Pendiente 95 Intersecci n Cl Error Est ndar S R Cl mg dL mg dL 0 94 a 0 96 2 76 a 6 87 9 73 0 99 Precision Dentro de la precisi n ejecu
6. Inc Rev date Fecha de revisi n 03 2011 AW 067039014
7. Make sure your meter and test strips are about the same temperature before you test Apply only OneTouch Verio Control Solution or a blood sample to the test strip Do Not put the used test strip back in the vial after taking a test Used test strips may be considered biohazardous waste in your area Be sure to follow your health care professional s advice or local laws when throwing them away ZN WARNING Keep the test strip vial away from children Test strips are a choking hazard Do Not swallow test strips The test strip vial may contain drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation Do Not ingest or swallow any items Testing Your Blood Glucose Read your system Owner s Booklet for instructions on running a blood test and getting a blood sample Test Results The OneTouch Verio Family of Meters shows results between 20 and 600 mg dL Read these cautions when your test results are higher or lower than what you expect ZA CAUTION Low glucose results If your test result is below 70 mg dL or a low glucose warning it may mean low blood glucose hypoglycemia You may need to treat low glucose right away Follow your health care professional s advice The result could be due to a test error but it is safer to treat first then test again Dehydration and low glucose results You may get false low glucose results if you are severely dehydrated If you think this is the case co
8. e su an lisis es menor a 70 mg dL o si un mensaje de advertencia indica un nivel bajo de glucosa posiblemente se trate de bajo nivel de glucosa en la sangre hipoglucemia Es posible que deba tratar el nivel bajo de glucosa inmediatamente Siga las indicaciones de su profesional del cuidado de la salud Aunque este resultado podr a deberse a un error de la prueba es m s seguro tratarse primero y luego volver a realizar otra prueba Deshidrataci n y resultados de glucosa baja Es posible que obtenga resultados de glucosa baja falsos si se encuentra seriamente deshidratado Si considera que este es su caso comun quese con su profesional del cuidado de la salud inmediatamente Resultados de glucosa alta Si el resultado de su prueba es superior a 180 mg dL posiblemente se trate de alto nivel de glucosa en sangre hiperglucemia Probablemente deba volver a realizar otra prueba Si le preocupa un nivel alto de glucosa en sangre consulte a su profesional del cuidado de la salud Una advertencia de nivel alto de glucosa aparece cuando su nivel de glucosa en la sangre es superior a 600 mg dL Esto podr a indicar glucosa muy alta en la sangre hiperglucemia grave Vuelva a hacer la prueba de glucosa en la sangre Si el resultado es una advertencia de glucosa alta esto indica un problema grave con el control de su glucosa en la sangre Obtenga y siga las instrucciones del profesional del cuidado de la salud inmediatamente Repetici n de resul
9. ects Tests mg dL 100 300 0 95 481 95 Cl 95 Cl Intercept Std Error Sad R Slope mg dL mg dL 0 94 to 0 96 2 76 to 6 87 9 73 0 99 Precision Within Run Precision 300 Venous Blood Tests Target Glucose Mean Glucose Standard Deviation Coefficient of mg dL mg dL mg dL Variation 40 42 39 1 21 2 86 100 97 43 1 84 1 89 130 130 24 249 1 91 200 196 15 3 96 2 02 350 330 34 7 39 2 24 Results show that the greatest variability observed between test strips when tested with blood is 2 86 or less Total Precision 600 Control Solution Tests Glucose Level Ranges Mean Glucose Standard Deviation Coefficient of mg dL mg dL mg dL Variation Low 38 62 50 31 1 77 3 52 Normal 102 138 117 14 2 70 2 31 High 298 403 342 34 8 68 2 53 Data generated using the OneTouch Verio IQ meter The OneTouch Verio IQ meter is representative of the OneTouch Verio Family of Meters Refer to your system Owner s Booklet for performance data specific to your system IMPORTANT For instructions technical data and a list of symbols used read your system Owner s Booklet References 1 American Diabetes Association Position Statement Diagnosis and Classification of Diabetes Mellitus Diabetes Care 31 555 S60 2008 R COMMITMENT TO YOU Our goal is to provide you with quality health care products and dedicated customer service If you are not fully satisfied with this product or if you have questi
10. ested that glucose meters should agree within 15 mg dL of a laboratory method when the glucose concentration is lower than 75 mg dL and within 20 of a laboratory method when the glucose concentration is 75 mg dL or higher Samples from 100 patients were tested using both the OneTouch Verio IQ System and the YSI 2300 Glucose Analyzer laboratory instrument System Accuracy Results for Glucose Concentrations lt 75 mg dL Percent and number of meter results that match the laboratory test Within Within Within 5 mg dL 10 mg dL 15 mg dL 88 2 100 0 100 0 45 51 51 51 51 51 System Accuracy Results for Glucose Concentrations 275 mg dL Percent and number of meter results that match the laboratory test Within Within Within Within 15 10 15 20 71 1 94 8 98 0 100 177 249 236 249 244 249 249 249 System Accuracy Results across the entire Glucose Range Percent and number of meter results that match the laboratory test Within 15 mg dL or 20 100 300 300 Therefore 100 of the total results obtained with the OneTouch Verio IQ System achieved the goal suggested by the diabetes experts Regression Statistics Samples were tested in duplicate on each of three test strip lots Results indicate that the OneTouch Verio IQ System compares well with a laboratory method of of Slope Intercept Subj
11. ing in blood at high normal or at high therapeutic concentrations do not significantly affect results However abnormally high concentrations in blood may cause inaccurately low results Tolazamide levels up to 7 5 mg dL 3x the level found at high therapeutic levels do not affect the blood glucose results Test results may be falsely low if the patient is severely dehydrated in shock or in a hyperosmolar state with or without ketosis Critically ill patients should not be tested with blood glucose meters Lipemic samples Cholesterol levels up to 700 mg dL and triglycerides up to 3000 mg dL do not affect the results Grossly lipemic patient samples have not been evaluated and are not recommended for testing with the OneTouch Verio Family of Meters ZA CAUTION The OneTouch Verio Family of Blood Glucose Monitoring Systems should not be used for patients within 24 hours of receiving a D xylose absorption test as it may cause inaccurately high results Alternate Site Limitations Refer to the Owner s Booklet that came with your meter for the full system Intended Use Some meter systems are not indicated for Alternate Site Testing Results from forearm or palm samples may differ from results using fingertip samples This is due to normal differences in blood flow It does not reflect system accuracy Be sure to talk to your health care professional before using your forearm or palm for sampling Differences in blood glucose readings be
12. le blood samples drawn from the fingertips The OneTouch Verio Family of Blood Glucose Monitoring Systems is intended to be used by a single patient and should not be used for testing multiple patients Refer to the Owner s Booklet that came with your meter for the full system Intended Use Storage and Handling Store the test strip vial in a cool dry place between 41 F and 86 F Keep away from direct sunlight and heat Exposure to temperatures and or humidity outside the storage limits may cause inaccurate readings e The expiration date is printed on the vial The discard date is 6 months after you first open a test strip vial When you open a new vial write the discard date on the label Do Not use after the expiration or discard date whichever comes first Store your test strips in the vial only To avoid damage or contamination Do Not put test strips in any other container Open the vial only when taking out a test strip for use Close the vial lid tightly right away after removing a test strip Use each test strip as soon as you take it out of the vial Do Not use test strips from a vial that is damaged or left open to air Do Not get dirt food or liquids on the test strip You may touch the test strip anywhere on its surface with clean dry hands Do Not bend cut or alter test strips in any way e Test strips are for single use only Never reuse a test strip that already has blood or control solution on it
13. ntact your health care professional right away High glucose results If your test result is above 180 mg dL it may mean high blood glucose hyperglycemia You should think about re testing Talk to your health care professional if you are concerned about high blood glucose A high glucose warning is shown when your blood glucose level is over 600 mg dL You may have very high blood glucose severe hyperglycemia Re test your blood glucose If the result is a high glucose warning again this indicates a severe problem with your blood glucose control Obtain and follow instructions from your health care professional right away Repeated unexpected glucose results If you get repeated unexpected results Runa control solution test to check your system e Make sure you follow all instructions in your Owner s Booklet e If your symptoms don t match your blood glucose results call your health care professional Never ignore symptoms or make significant changes to your diabetes management program without speaking to your health care professional Range of Expected Values Blood glucose management requires the help of a health care professional Talk to your health care professional about The target blood glucose range that is right for you e When to test What your blood glucose results mean Expected blood glucose levels for non pregnant people without diabetes Time Range mg dL Fasting Less than 100 2 hours after meals Les
14. ons about the use of any LifeScan product contact us 7 days a week 8 a m 10 p m Eastern Time at 1 888 567 3003 English If you cannot reach Customer Service contact your health care professional for advice Covered by one or more of the following U S patents 6 179 979 6 284 125 6 716 577 6 749 887 6 863 801 7 045 046 7 498 132 and 7 846 312 Use of these test strips and associated monitoring device is protected under the following U S patents 6 413 410 7 749 371 Purchase of the associated monitoring device does not act to grant a use license under these patents Such a license is granted only when the associated monitoring device is used with OneTouch Verio Test Strip No test strip supplier other than LifeScan Inc is authorized to grant such a license The accuracy of results generated with LifeScan meters using test strips manufactured by anyone other than LifeScan has not been evaluated by LifeScan Diagn stico in vitro Para hacer sus propias pruebas IMPORTANTE lea este prospecto y su Manual del propietario antes de utilizarlo El Manual del propietario tiene instrucciones completas para pruebas de glucosa en la sangre y con soluci n de control No utilice tiras reactivas nuevas si el frasco est abierto o da ado de alg n modo Esto puede producir mensajes de error o resultados de glucosa en sangre inexactos Comun quese con el Servicio al Cliente de LifeScan inmediatamente al 1 888 567 3010 Espa ol los 7 d
15. ontenidas en la tira reactiva para producir una corriente el ctrica La potencia de la corriente cambia seg n la cantidad de glucosa contenida en la muestra de sangre La familia de medidores OneTouch Verio mide la corriente calculan el nivel de glucosa en la sangre y muestran el resultado Composici n del reactivo Cada tira reactiva contiene glucosa deshidrogenasa con flavina adenina dinucle tido o GDH FAD de Aspergillus sp 2 U ferricianuro de potasio 41 ug y otros ingredientes soluci n neutralizadora etc El frasco contiene un agente desecante Caracter sticas de rendimiento El rendimiento de las tiras reactivas OneTouch Verio se ha evaluado tanto en laboratorio como en pruebas cl nicas Intervalo de medici n el intervalo de medici n de la familia de medidores OneTouch Verio es 20 a 600 mg dL Precisi n del sistema Expertos en diabetes han sugerido que los medidores de glucosa deben tener una coincidencia dentro del margen de 15 mg dL de un m todo de laboratorio cuando la concentraci n de glucosa es inferior a75 mg dL y dentro del margen de 20 de un m todo de laboratorio cuando la concentraci n de glucosa es 75 mg dL o superior Se evaluaron muestras de 100 pacientes usando tanto el sistema OneTouch Verio IQ como el instrumento de laboratorio para analizar glucosa YSI 2300 Resultados de precisi n del sistema usando concentraciones de glucosa lt 75 mg dL Porcentaje
16. reguntas acerca del uso de cualquiera de los productos de LifeScan comun quese con nosotros los 7 d as de la semana de 8 a m a 10 p m hora del este al 1 888 567 3010 Espa ol Si no puede ponerse en contacto con Servicio al Cliente comun quese con su profesional del cuidado de la salud para que lo asesore Cubierto por una o m s de las siguientes patentes de Estados Unidos 6 179 979 6 284 125 6 716 577 6 749 887 6 863 801 7 045 046 7 498 132 y 7 846 312 El uso de estas tiras reactivas y el dispositivo de supervisi n asociado est protegido por las siguientes patentes de Estados Unidos 6 413 410 7 749 371 La compra de este dispositivo de supervisi n asociado no otorga una licencia de uso conforme a estas patentes Dicha licencia se otorga nicamente cuando el dispositivo de supervisi n asociado se utiliza con las tiras reactivas OneTouch Verio Ning n otro distribuidor de tiras reactivas que no sea LifeScan est autorizado a otorgar dicha licencia LifeScan no ha evaluado la precisi n de los resultados generados con los medidores LifeScan utilizando tiras reactivas fabricadas por otros distribuidores que no sean LifeScan Made in Australia Fabricado en Australia Distributed by Distribuido por LifeScan Inc Milpitas CA 95035 USA For Para LifeScan Europe Division of Cilag GmbH International 6300 Zug Switzerland oy ae PECAN amp LIFESCAN AL afohmon fohuon company 2011 LifeScan
17. s than 140 Checking the System Use only OneTouch Verio Control Solutions A control solution test is used to check that The meter and test strips are working together properly e You are doing the test correctly Do a control solution test e When you open a new vial of test strips If you think the meter or test strips are not working properly Ifyou get repeated unexpected blood glucose results Ifyou drop or damage the meter Read your system Owner s Booklet for instructions on how to run a control solution test Limitations of Procedure OneTouch Verio Test Strips give accurate results under the following conditions Use only fresh capillary whole blood Do Not use serum or plasma Hematocrit is the percentage of red blood cells in the blood Extremes in hematocrit may affect test results Hematocrit levels below 20 may cause false high readings Hematocrit levels over 60 may cause false low readings Talk to your health care professional ifyou don t know your hematocrit level OneTouch Verio Test Strips may be used at altitudes up to 10 000 feet with no effect on test results Fresh capillary blood samples may be collected into sodium heparin lithium heparin potassium EDTA and sodium citrate containing test tubes if the blood is used within 10 minutes Do Not use sodium fluoride oxalate or other anticoagulants or preservatives nterferences Acetaminophen ascorbic acid vitamin C and uric acid when occurr
18. sco nuevo de tiras reactivas e Si sospecha que el medidor o las tiras reactivas no est n funcionando correctamente e Si obtiene resultados inesperados de glucosa en la sangre en repetidas ocasiones Si el medidor se cay o se da Consulte en el Manual del propietario del sistema las instrucciones para realizar una prueba con soluci n de control Limitaciones del procedimiento Las tiras reactivas OneTouch Verio arrojan resultados precisos en las siguientes condiciones Deben utilizarse nicamente con sangre completa capilar reci n extra da No utilice suero ni plasma El hematocrito es el porcentaje de gl bulos rojos en la sangre Los extremos en el valor de hematocrito pueden afectar los resultados de la prueba Los niveles de hematocrito inferiores al 20 pueden producir lecturas altas falsas Los niveles de hematocrito superiores al 60 pueden producir lecturas bajas falsas Si no conoce su nivel de hematocrito consulte a su profesional del cuidado de la salud e Las tiras reactivas OneTouch Verio se pueden utilizar en altitudes de hasta 10 000 pies sin afectar los resultados de la prueba Se puede recolectar sangre capilar reci n extra da en tubos de ensayo que contengan heparina heparina de litio EDTA de potasio y citrato de sodio si la sangre se utiliza dentro de los 10 minutos siguientes No utilice oxalato fluoruro de sodio ni otros anticoagulantes ni conservantes e Interferencias el acetaminof n
19. tada 300 pruebas de sangre venosa Objetivo de glucosa Promedio de glucosa Desviaci n est ndar Coeficiente de mg dL mg dL mg dL variaci n 40 42 39 1 21 2 86 100 97 43 1 84 1 89 130 130 24 2 49 1 91 200 196 15 3 96 2 02 350 330 34 739 2 24 Precisi n total 600 pruebas de soluci n de control Los resultados muestran que la maxima variabilidad observada entre tiras reactivas cuando se realizan pruebas con sangre es 2 86 o menos Nivel de glucosa Promedio de glucosa Desviaci n est ndar Coeficiente de mg dL mg dL mg dL variaci n Baja 38 62 50 31 1 77 3 52 Normal 102 138 117 14 2 70 2 31 Alta 298 403 342 34 8 68 2 53 Los datos fueron generados utilizando el medidor OneTouch Verio IQ El medidor OneTouch Verio IQ es representativo de la familia de medidores OneTouch Verio Consulte el Manual del propietario para el rendimiento de los datos espec ficos de su sistema IMPORTANTE para obtener instrucciones datos t cnicos y una lista de s mbolos usados lea el Manual del propietario del sistema Referencias 1 American Diabetes Association Position Statement Diagnosis and Classification of Diabetes Mellitus Diabetes Care 31 555 S60 2008 NUESTRO COMPROMISO CON USTED Nuestra meta es proporcionarle productos para el cuidado de la salud de calidad y un servicio al cliente dedicado Si no est completamente satisfecho con este producto o si tiene p
20. tados de glucosa inesperados Si obtiene resultados inesperados en repetidas ocasiones e Realice una prueba con soluci n de control para verificar el funcionamiento del sistema Siga todas las instrucciones del Manual del propietario e Si tiene s ntomas que no coinciden con los resultados de la glucosa en la sangre llame a su profesional del cuidado de la salud Nunca ignore s ntomas ni realice cambios significativos en su programa de control de la diabetes sin consultar a su profesional del cuidado de la salud Intervalo de valores esperados El control de glucosa en la sangre requiere de la ayuda de un profesional del cuidado de la salud Consulte a su profesional del cuidado de la salud lo siguiente El intervalo objetivo de glucosa en la sangre adecuado para usted Cu ndo debe realizar una prueba El significado de sus resultados de glucosa en la sangre Niveles previstos de glucosa en la sangre de personas que no est n embarazadas y que no padecen diabetes Intervalo de tiempo Intervalo de mg dL Menos de 100 Menos de 140 En ayunas 2 horas despu s de las comidas Comprobaci n del sistema Use nicamente soluciones de control OneTouch Verio Una prueba con soluci n de control se usa para verificar que El medidor y las tiras reactivas est n funcionando correctamente e Usted est realizando la prueba correctamente Realice una prueba con la soluci n de control e Cuando comience a usar un fra
21. to y manipulaci n Guarde el frasco de tiras reactivas en un lugar fresco y seco a una temperatura de entre 41 F y 86 F Mant ngalo alejado del calor y de la luz directa del sol La exposici n a temperaturas y o humedad que no cumplan con estas condiciones de almacenamiento puede producir lecturas inexactas La fecha de vencimiento est impresa en el frasco La fecha de descarte es 6 meses despu s de haber abierto el frasco de tiras reactivas por primera vez Cuando abra por primera vez un frasco nuevo anote la fecha de descarte en la etiqueta No utilice despu s de la fecha de vencimiento o de descarte lo que suceda primero Guarde las tiras reactivas en el frasco nicamente A fin de evitar contaminaci n o da os no las coloque en ning n otro recipiente Abra el frasco nicamente cuando deba sacar una tira reactiva para usar Cierre bien la tapa del frasco inmediatamente despu s de sacar una tira reactiva Use cada tira reactiva inmediatamente despu s de sacarla del frasco No utilice las tiras reactivas de un frasco que est da ado o que se haya dejado abierto No permita que la tira reactiva entre en contacto con polvo alimentos o l quidos Puede tocar cualquier parte de la superficie de la tira reactiva con las manos limpias y secas Las tiras reactivas no deben doblarse cortarse ni alterarse de ninguna manera Las tiras reactivas deben utilizarse s lo una vez No vuelva a utilizar una tira reactiva en la que se ha
22. tween the fingertip and other sites may occur after eating insulin medication or exercise This is because blood sugar levels change faster in the fingertip Alternate site testing AST should not be used to calibrate continuous glucose monitors CGMs or to calculate an insulin dose AST testing should only be done during steady state times when glucose is not changing rapidly Please note that the OneTouch Verio IQ meter is not indicated for Alternate Site Testing Test Principle The OneTouch Verio Family of Meters is plasma calibrated for easy comparison of results with lab methods Glucose in the blood sample mixes with special chemicals on the test strip to produce an electrical current The strength of the current changes with the amount of glucose in the blood sample The OneTouch Verio Family of Meters measures the current calculates your blood glucose level and shows your result Reagent Composition Each test strip contains flavin adenine dinucleotide dependent glucose dehydrogenase or FAD GDH from Aspergillus sp 2 U potassium ferricyanide 41 ug and other ingredients buffer etc The vial contains a drying agent Performance Characteristics The performance of the OneTouch Verio Test Strip has been evaluated both in laboratory and in clinical tests Measurement Range The measurement range of the OneTouch Verio Family of Meters is 20 to 600 mg dL System Accuracy Diabetes experts have sugg
23. ya aplicado previamente sangre o soluci n de control Antes de realizar la prueba aseg rese de que el medidor y las tiras reactivas est n aproximadamente a la misma temperatura Aplique nicamente soluci n de control OneTouch Verio o una muestra de sangre en la tira reactiva No vuelva a colocar la tira reactiva usada en el frasco despu s de realizar una prueba Es posible que en su rea las tiras reactivas usadas se consideren desechos de riesgo biol gico Aseg rese de seguir las indicaciones de su profesional del cuidado de la salud o las leyes locales para desecharlas de manera adecuada ZA ADVERTENCIA mantenga el frasco de tiras reactivas fuera del alcance de los ni os Las tiras presentan riesgo de asfixia Las tiras reactivas no deben ingerirse El frasco de tiras reactivas puede contener agentes desecantes que son nocivos si se inhalan o se ingieren y que pueden irritar la piel y los ojos No ingiera ni trague ninguno de estos art culos Realizaci n de pruebas de glucosa en la sangre Consulte en el Manual del propietario del sistema las instrucciones para realizar una prueba de sangre y obtener una muestra de sangre Resultados de la prueba La familia de medidores OneTouch Verio muestra resultados con valores entre 20 y 600 mg dL Lea estas precauciones cuando los resultados de una prueba sean m s altos o m s bajos de lo que usted espera ZA PRECAUCI N Resultados de glucosa baja Si el resultado d
Download Pdf Manuals
Related Search
Related Contents
焼灼術用電気手術ユニット(マイクロ波手術器) intext:Bedienungsanleitung filetype:pdf Rust-Oleum Automotive 260771 Use and Care Manual AC 65/180 AC 65/180 X AC 80/180 AC 80/180 X AC 110/180 X TV Instrucciones de manejo 3155 (Combo 3/6) Combination Snack/Beverage Sub-Zero 7011712 Refrigerator User Manual Manhattan 150927 Philips SHM1500K Manual do usuário Copyright © All rights reserved.