Home

Model 45HB-70HB

image

Contents

1. ages are recommended where available Rotation Three phase rotation must be checked at instal lation my momentarily energizing the completely filled pump and observing the rotation Rotation is clockwise looking into the motor shaft end bell side remove pro tective cap to observe shaft Rotation must correspond to rotation arrow Rotation of three phase units can be reversed by interchanging any two 2 electrical power leads CAUTION Do Not run in reverse rotation or damage will result OPERATION Fill suction line and pump with liquid to be pumped to insure mechanical seal will not run dry With pump and suction line completely filled and motor properly wired the unit may be started Be sure pump is not started against a closed valve in the discharge line MAINTENANCE 1 Lubrication Pumps should require no maintenance other than the motor bearings In hot or severe service lubricate every 3 months Follow motor manufacturer s instruc tions to determine lubrication schedule Lubricate with power off and motor warm Remove upper and lower plugs at both bearing Free lower relief hole of hard grease Install clean grease fitting on upper hole and add grease with a low pressure grease gun Run motor 30 minutes Stop motor and remove drained grease Replace all plugs CAUTION Do Not over grease DISASSEMBLY Turn off all electrical power Drain system Disconnect piping 1 2 3 4 Remove bolts holding mo
2. ne pas ab mer ni salir les surfaces polies de la garniture m canique neuve Placer le moteur la verticale l arbre vers le haut et reposer l ensemble corps d aspiration adaptateur de moteur tout en s assurant que l arbre de moteur ne d loge pas l l ment fixe de la garniture m canique neuve 3 10 11 12 13 14 15 16 17 18 Enduire d un peu d huile l g re ou d eau savonneuse la surface ext rieure de l ensemble accouplement chemise d arbre et la surface int rieure de la partie en caoutchouc de l l ment mobile de la garniture m canique neuve Enfiler P trier de retenue du ressort de garniture le ressort puis l l ment mobile de la garniture sur l ensemble accouplement chemise d arbre tout en s assurant que la surface d tanch it de la garniture reste dans son collier de retenue et que l trier de retenue du ressort est enti rement appuy contre l paulement de l ensemble accouplement chemise d arbre ATTENTION veiller ne pas abimer ni salir les surfaces polies de la garniture m canique neuve Enduire les filets de l arbre de moteur de Loctite n 271 Visser l ensemble accouplement chemise d arbre avec l l ment mobile de la garniture m canique fond sur l arbre de moteur avec une cl de 12 po tout en bloquant l arbre de moteur avec un tournevis ins r dans la fente de celui ci Avec une r gle rectifi e plac
3. L arbre devrait tourner sans autre r sistance que celle de la garniture m canique Reposer l anneau lastique 1 Remettre l obturateur de l extr mit d arbre de moteur en place Remplir la conduite d aspiration et la pompe d eau avant de mettre celle ci en marche ce sujet voir la section UTILISATION 11 PI CES DE RECHANGE 2 21 22 L pasi 77 db 1 25 23 24 d art Nom de pi ce N de moule N d art Nom de pi ce N de moule 1 Anneau lastique 15 Rondelle vis de l accouplement 2 T te de refoulement orifice de 2 po NPT 57209 16 Vis accouplement 3 Coussinet cannel t te de refoulement 17 Bague de retenue 4 Chemise d arbre t te de refoulement 18 Chemise d arbre 5 Diffuseur 19 trier de retenue ressort de garniture 6 Roue m canique 7 Corps d tage 20 Garniture m canique 8 Cale 21 Corps d aspiration orifice de 2 po NPT 59098 9 Corps de pompe 22 Adaptateur de moteur carcasse 210 59153 10 Ensemble accouplement arbre Adaptateur de moteur carcasses 140 a 180 59099 11 51266 interm diaire 57203 23 Vis t te hexagonale adaptateur moteur 12 Coussinet cannel tage interm diaire 24 adaptateur corps 13 Chemise d arbre
4. e en travers des bords du corps d aspiration v rifier la position de l extr mit ext rieure de l ensemble accouplement chemise d arbre En raison de variations dans la longueur de l arbre de moteur ou de certaines pi ces de la pompe l extr mit peut soit affleurer la r gle soit en tre une distance maximale de 0 080 po l int rieur Si l extr mit de l ensemble est l int rieur du corps d aspiration poser des cales de 0 010 po contre l extr mit jusqu ce qu une 1 cale d passe le bord de la r gle rectifi e Remonter les tages de la pompe un par un en v rifi ant la position du moyeu de roue par rapport aux bords du corps d tage avec une r gle rectifi e Le moyeu doit affleurer ou d passer le bord de la r gle Au besoin ajouter des cales de 0 010 po Dans le cas des mod les de 10 hp poser une bague support de coussinet au milieu de la s rie d tages une chemise d arbre 13 et les cales n cessaires Reposer la chemise d arbre 4 Appliquer un enduit d tanch it pour filets Loctite HVV pour tuyaux sur les filets du corps d aspiration et de la t te de refoulement servant visser le corps de pompe puis y visser ce dernier 50 Ibf pi ATTEN TION ne pas mettre d enduit d tanch it sur les filets du corps de pompe Avec une douille de po enfil e sur le bout de l arbre de pompe par l orifice de la t te de refoulement tourner l arbre la main en sens antihoraire
5. shoulder of sleeve coupling CAUTION Take care to prevent damage or dirt on lapped faces of the new mechanical seal 7 Coat motor shaft threads with Loctite 271 8 Thread the shaft sleeve coupling with rotating por tion of mechanical seal in place onto the threaded motor shaft until the sleeve coupling bottoms on the motor shaft shoulder Use screwdriver in motor shaft slot to hold while tightening the shaft assembly with a V wrench 9 Use a straight edge across face of suction housing to check location of outboard end of shaft sleeve cou pling Due to variations in motor shaft lengths and pump parts it will be from 0 080 short below the straight edge to flush 10 If sleeve coupling is below the straight edge add 0 010 shims until top face of shims are one 1 shim higher than straight edge interferes with straight edge 11 Reassemble stages on shaft checking impeller hub height after each stage Hub must be flush with straight edge or higher Add 0 010 shims as neces sary 11a On 10 HP models install bearing spider at half way point in the stack use shaft sleeve 13 and shim accordingly 12 Install shaft sleeve 4 on shaft 13 Apply thread sealant Loctite HVV Pipe Sealant to suction housing 21 threads plus discharge head 2 threads and reassemble casing to pump Tighten to 50 foot pounds torque CAUTION Do Not apply sealant to casing threads 14 Turn pump by hand with a 2 socket
6. bomba Apriete a una torsi n de 50 pie libras PRECAUCI N No aplique sellador a las roscas de la carcasa Gire la bomba a mano con una boquilla de Y pulg sobre el extremo del eje de la bomba dentro del cabezal de descarga 2 Gire en sentido contraho rario La unidad debe girar con resistencia del sello mec nico del eje nicamente 14a Reinstale el anillo de resorte 1 sobre el eje 15 16 Reinstale el tap n del extremo del motor No arranque la unidad hasta que la tuber a de suc ci n y la bomba est n completamente llenas con agua Consulte la secci n de OPERACI N PARTES DE REPUESTO 21 22 clas gt d 9 13 18 23 24 Art culo Nombre de la parte Patron N Art culo N Nombre de la parte Patron N 1 Anillo de retenci n 15 Arandela tornillo del acoplamiento 2 Conjunto del cabezal de descarga 16 Tornillo mec nico NPT de 2 pulg 57209 17 Anillo de retenci n 3 Cojinete estilo marino cabezal de descarga 18 Camisa del eje 4 Camisa cabezal de descarga 19 Ret n del resorte 5 Difusor 20 Conjunto del sello mec nico 6 mpulsor 21 Caja de succi n NPT de 2 pulg 59098 7 Copa 22 Adaptador para el motor bastidor 210 59153 8 Plancha de relleno Adaptador para el motor bast
7. cuando est n disponibles Rotaci n La rotaci n trif sica debe ser verificada en el momento de la instalaci n energizando moment nea mente la bomba completamente llena y observando la rotaci n La rotaci n es en sentido horario cuando se observa hacia el eje del motor lado de la campana del ex tremo retire la tapa protectora para observar el eje La rotaci n debe corresponder con la flecha de rotaci n La rotaci n de las unidades trif sicas puede invertirse inter cambiando dos 2 conductores de alimentaci n el ctrica cualquiera PRECAUCI N No haga funcionar la unidad en rotaci n inversa o se producir n da os OPERACI N Llene la tuber a de succi n y la bomba con el l quido que se va a bombear para asegurar que el sello mec nico no funcione en seco Con la bomba y la tuber a de suc ci n completamente llenas y con el motor conectado correctamente puede ponerse en marcha la unidad Aseg rese de que la bomba no sea puesta en marcha con tra una v lvula cerrada en la tuber a de descarga MANTENIMIENTO 1 Lubricaci n Las bombas no requieren mantenimiento excepto por los cojinetes del motor En servicio riguroso o a temperaturas elevadas lubrique cada 3 meses Siga las instrucciones del fabricante del motor para determinar el horario de lubricaci n Lubrique con el suministro el ctrico apagado y el motor tibio Retire los tapones superior e inferior en ambos cojinetes Quite la grasa endurecida del o
8. la pompe 5 Ne jamais pomper de liquides dangereux ni de solvants 6 La temp rature maximale du liquide pomp est de 82 C 180 7 La pression d aspiration maximale est de 100 Ib po INSTALLATION Emplacement placer la pompe aussi pr s de la source de liquide que possible Pr voir assez d espace autour de la pompe pour l entretien et l a ration Prot ger l appareil de la pluie des inondations et du gel On peut monter la pompe l horizontale ou la verticale le moteur au dessus condition que celui ci soit prot g avec un cran pare gouttes Surface portante la surface portante doit tre plane afin d emp cher que le serrage des boulons d ancrage ne cause de d formation ni de contraintes ATTENTION le boulonnage et la tuyauterie ne doivent appliquer aucune contrainte sur la t te de pompage Les pompes ont un fonctionnement r gulier et silencieux mais on recom mande de les monter sur caoutchouc si la surface portante r sonne Alignement aucun alignement sur place n est requis tant donn que les pompes sont mont es sur moteur Tuyauterie le calibre du tuyau d aspiration doit tre au moins gal celui du raccord d aspiration de la pompe et permettre la pompe d avoir une hauteur totale de charge absolue l aspiration pression d aspiration viter les utilisations n cessitant une hauteur d aspiration Ne jamais employer un robinet vanne sur le tuyau d aspiration pour r duire la section
9. over the end of the pump shaft inside the discharge head 2 Turn counter clockwise Unit should turn with resistance of only the mechanical shaft seal 14a Replace snap ring 1 on shaft 15 Replace motor end plug 16 Do not start unit until suction line and pump are completely filled with water Refer to OPERATION Section REPATR PARTS 21 22 fo 7 d 12 23 24 Item No Part Name Pattern No Part No Part Name Pattern No 1 Retaining ring 15 Washer coupling screw 2 Discharge head assembly 2 NPT 57209 16 Mechanical screw 3 Marine bearing Discharge head 17 Retaining ring 4 Sleeve Discharge head 18 Shaft sleeve 5 Diffuser 19 Spring retainer 6 Impeller 20 Mechanical seal assembly 7 Bowl 21 Suction housing 2 NPT 59098 8 Shim 22 Motor adapter 210 frame 59153 9 Casing Motor adapter 140 180 frame 59099 10 Shaft coupling assembly 23 Hex cap screw adapter to motor 11 Intermediate stage assembly 57203 24 Hex cap screw adapter to suction housing 12 Marine bearing Intermediate stage 25 Pipe Plug 1 4 NPT 13 Sleeve Intermediate stage Note Shaft assembly includes screw 16 and washer 15 14 Coupling GOULDS WATER TECHNOLOGY LIMITED WARRANTY This warranty ap
10. tage interm diaire 25 Bouchon detuyaude Apo NPT 14 Accouplement Nota l ensemble comprend la rondelle 15 et la vis 16 GARANTIE LIMITFE DE Goulds Water Technology La pr sente garantie s applique chaque pompe de syst me d alimentation en eau fabriqu e par Goulds Water Technology Toute pi ce se r v lant d fectueuse sera remplac e sans frais pour le d taillant durant la p riode de garantie suivante expirant la premi re douze 12 mois compter de la date d installation ou dix huit 18 mois partir de la date de fabrication Le d taillant qui aux termes de cette garantie d sire effectuer une demande de r glement doit s adresser au distributeur Goulds Water Technology agr chez lequel la pompe a t achet e et fournir tous les d tails l appui de sa demande Le distributeur est autoris r gler toute demande par le biais du service la client le de Goulds Water Technol ogy La garantie ne couvre pas a les frais de main d uvre ou de transport ni les frais connexes encourus par le d taillant b les frais de r installation de l quipement r par c les frais de r installation de l quipement de remplacement d les dommages indirects de quelque nature que ce soit e niles pertes d coulant de la panne Aux fins de la pr sente garantie les termes ci dessous sont d finis comme suit 1 Distributeur signifie une personne une soci t de personnes une soc
11. INSTRUCTION MANUAL 023 Model 45HB 70HB MULTI STAGE CENTRIFUGAL BOOSTER PUMP INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL GOULD LATA gt f WATER TECHNO a xylem brand GENERAL INFORMATION Models 45HB and 70HB are multi stage high pressure general purpose centrifugal booster pumps using en closed impellers Applicable for clear non hazardous liquids in general industrial services up to 180 F 82 C Particularly suited for high pressure booster services All models are close coupled to electric motors contain ing prelubricated bearings designed for continuous ser vice Threaded shaft extension is protected by a stainless steel sleeve coupling combination All models are equipped with single unbalanced mechan ical shaft seals Units are shipped completely assembled and ready for installation IMPORTANT 1 Inspect unit for shipping damage 2 Read all instructions carefully 3 ALWAYS disconnect all electrical power when han dling pump motor or controls 4 Do not run unit dry or against a closed discharge This will result in damage to mechanical seal and pump 5 Never pump hazardous liquids or solvents 6 Maximum liquid temperature 180 F 82 C 7 Maximum inlet pressure 100 PSI INSTALLATION Location Locate pump as near the liquid source as prac tical Allow adequate room for servicing and ventilation Protect the unit from cold weat
12. de passage vers la pompe ATTEN TION la tuyauterie ne doit appliquer aucune contrainte sur la t te de pompage C blage l alimentation lectrique doit tre assur e par un circuit de d rivation distinct dont les fusibles les disjonc 10 teurs les d marreurs le calibre des fils etc sont appro pri s et conformes aux prescriptions du code provincial ou national de l lectricit La tension d alimentation le nom bre de phases et les commandes doivent tre conformes aux sp cifications de la plaque signal tique du moteur Une protection contre les basses tensions lectriques et les pertes de phase en triphas est recommand e Moteurs les moteurs sont tous courant alternatif 60 Hz Ceux de 3 hp sont monophas s bitension 115 230 V ceux de 5 hp monophas s simple tension 230 V et tous les autres triphas s bitension 230 460 V Il est recommand d employer la tension la plus haute quand cela est possible Sens de rotation s il s agit d une pompe moteur tripha s on doit en v rifier le sens de rotation avant de la mettre en service en la remplissant d abord d eau puis en la mettant en marche et en l arr tant imm diatement tout en observant le sens de rotation de l arbre de moteur visible une fois l obturateur de l extr mit d arbre de moteur t L arbre doit tourner en sens horaire comme l indique la fl che pr vue cet effet On peut inverser le sen
13. do del motor hasta que la camisa aco plamiento haga contacto con el reborde del eje del motor Utilice un destornillador en la ranura del eje del motor para sujetar mientras aprieta el conjunto del eje con una llave de pulg Utilice un escantill n sobre la cara de la caja de suc ci n para verificar la ubicaci n del extremo exterior de la camisa acoplamiento del eje Debido a las variaciones de las longitudes del eje del motor y las partes de la bomba estar situado en el intervalo de 0 080 pulg m s corto debajo del escantill n hasta a ras Si la camisa acoplamiento est debajo del escantil l n agregue planchas de relleno de 0 010 pulgada hasta que la cara superior de las mismas sea una 1 plancha de relleno m s alta que el escantill n inter fiere con el escantill n Rearme las etapas sobre el eje verificando la altura del cubo del impulsor despu s de cada etapa El cubo debe estar a ras con el escantill n o m s alto Agregue planchas de relleno de 0 010 pulgada seg n sea necesario 11a En los modelos de 10 HB instale un cubo de balero 12 13 14 en un punto a medio camino en la pila utilice la camisa del eje 13 y la plancha de relleno en la forma correspondiente Instale la camisa del eje 4 sobre el eje Aplique sellador de roscas sellador de tuber a Loc tite HVV a las roscas de la caja de succi n 21 y a las roscas del cabezal de descarga 2 y reinstale la carcasa en la
14. e b los costos de reinstalaci n del equipo reparado c los costos de reinstalaci n del equipo reemplazado d da os emergentes de cualquier naturaleza y e el reembolso de cualquier p rdida causada por la interrupci n del servicio A los fines de esta garant a los t rminos Distribuidor Comerciante y Cliente se definen como sigue 1 Distribuidor es aquel individuo sociedad corporaci n asociaci n u otra persona jur dica que opera en relaci n legal entre Goulds Water Technology y el comerciante para la compra consignaci n o contratos de venta de las bombas en cuesti n 2 Comerciante es todo individuo sociedad corporaci n asociaci n u otra persona jur dica que en el marco de una relaci n legal realiza negocios de venta o alquiler venta leasing de bombas a clientes 3 Cliente es toda entidad que compra o que adquiere bajo la modalidad de leasing las bombas en cuesti n de un comerciante El t rmino cliente puede significar un individuo sociedad corporaci n sociedad de responsabilidad limitada asociaci n o cualquier otra persona jur dica con actividades en cualquier tipo de negocios LA PRESENTE GARANT A SE EXTIENDE AL COMERCIANTE NICAMENTE Xylem 2881 East Bayard Street Ext Suite A E Mater Seneca Falls NY 13148 Tel fono 800 453 6777 Fax 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds es una marca registrada de Goulds Pumps Inc y s
15. e utiliza bajo licencia 2012 Xylem Inc 1 023 Rev 3 Febrero 2012 MANUEL D INSTRUCTION 4023 Mod les 45115 et 7OHB POMPES DE SURPRESSION CENTRIFUGES MULTI TAG ES MANUEL D INSTALLATION D UTILISATION ET DE D PANNAGE o gGOULDS a xylem band INFORMATIONS G N RALES Les pompes mod les 45HB et 70HB sont des pompes de surpression centrifuges multi tag es roues ferm es pr vues pour un usage g n ral et pour les liquides indus triels limpides non dangereux de nature g n rale dont la temp rature ne d passe pas 82 C 180 F Elles convien nent particuli rement au pompage haute pression Elles sont toutes mont es sur un moteur lectrique muni de roulements pr lubrifi s pour un service continu Elles poss dent un arbre rallonge filet prot g par un ensem ble accouplement chemise d arbre en inox Leur arbre est dot d une garniture m canique non com pens e Elles sont exp di es assembl es et pr tes installer INFORMATIONS IMPORTANTES 1 V rifier si l appareil a t endommag pendant le transport 2 Lire toutes les directives avec soin 3 On doit TOUJOURS couper le courant lorsque l on effectue quelque travail que ce soit sur la pompe le moteur ou les commandes 4 Ne pas faire fonctionner la pompe sec ni quand le liquide ne peut circuler dans la conduite de refoule ment cause d un robinet ferm car cela endommag erait la garniture m canique et
16. eal Remove bolts holding adapter to motor Remove suction housing adapter combination from motor Place suction housing adapter on a flat surface and push out stationary portion of mechanical seal REASSEMBLY 1 w Clean all parts especially pump and motor register fits seal seat counter bore in suction housing and shaft in particular where shaft sleeve coupling fits against shaft shoulder Clean shaft sleeve coupling threads and motor shaft threads Clean old Loctite from threads with a wire brush Apply Locquic Primer T Loctite Product No 74756 available in Automotive Parts and Hard ware stores and allow to dry Lubricate counterbore of suction housing 21 and rubber bushing of new stationary seal seat with light oil or soapy water and press into counterbore squarely and evenly CAUTION Do Not mar or contaminate the lapped face of the new mechanical seal seat With motor in vertical position remount suction housing adapter on motor Make certain the mo tor shaft does not dislocate the new mechanical seal stationary seat Apply a thin coat of light oil or soapy water to outer surface of sleeve coupling and inside diameter of rub ber portion of the new rotating seal member 6 Slide spring retainer spring and rotating member of the new mechanical seal over the sleeve coupling making certain the seal face stays in the holding collar and spring retainer is squarely seated against
17. her freezing and water damage due to rain or flooding Pump may be mounted horizontal or vertical with motor on top provided a drip shield is used for motor protection Foundation Foundation surface must be flat so there is no distortion and or strain developed when tightening the foundation bolts CAUTION Bolting and or piping must not put strain on liquid end The pumps are quiet and smooth running but rubber mounting is recom mended on foundations susceptible to sound effect Alignment No filed alignment is necessary as pumps are close coupled Piping Suction pipe must be at least equal in size to suction connection of pump and provide positive suc tion head intake pressure to the pump Avoid using the pump for applications requiring suction lift Never use a gate valve in the suction line to throttle the pump CAU TION Piping must not put strain on the liquid end Wiring Electrical power supply must be a separate branch circuit equipped with proper starters fuses or circuit breakers wire size etc conforming to National Electrical Code plus local codes Power supply voltage phase and controls must match motor nameplate require ments Low voltage and phase loss 3 phase protection is recommended 2 Motors Single phase 3 HP motors are dual voltage 115 230 volts 60 Hz A C Single phase 5 HP motors are 230 volts 60 Hz A C All other motors are three phase dual voltage 230 460 volts 60 Hz A C The higher volt
18. i t de capitaux une association ou autre entit juridique servant d interm diaire entre Goulds Water Technology et le d taillant pour les achats les consignations ou les contrats de vente des pompes en question 2 D taillant veut dire une personne une soci t de personnes une soci t de capitaux une association ou autre entit juridique dont les activit s commerciales sont la vente ou la location de pompes des clients 3 Client signifie une entit qui ach te ou loue les pompes en question chez un d taillant Un client peut tre une personne une soci t de personnes une soci t de capitaux une soci t responsabilit limit e une association ou autre entit juridique se livrant quelque activit que ce soit CETTE GARANTIE SE RAPPORTE AU DETAILLANT SEULEMENT Xylem 2881 East Bayard Street Ext Suite pets soe Mater Seneca Falls NY 13148 T l phone 800 453 6777 t l copie 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds est une marque d pos e de Goulds Pumps Inc utilis e sous licence 2012 Xylem Inc 1 023 Rev 3 F vrier 2012
19. idor 140 180 59099 9 Carcasa 23 Tornillo de cabeza hexagonal 10 Conjunto del eje acoplamiento del adaptador al motor 11 Conjunto de etapa intermedia 57203 24 Tornillo de cabeza hexagonal 7 12 Cojinete estilo marino etapa intermedia del adaptador a la caja de succi n 13 Camisa etapa intermedia 25 Tap n de tuber a 1 4 NPT 14 Acoplamiento Nota El conjunto del eje incluye un tornillo 16 y una arandela 15 GARANTIA LIMITADA DE GOULDS WATER TECHNOLOGY Esta garant a es aplicable a todas las bombas para sistemas de agua fabricadas por Goulds Water Technology Toda parte o partes que resultaren defectuosas dentro del per odo de garant a ser n reemplazadas sin cargo para el comerciante durante dicho per odo de garant a Tal per odo de garant a se extiende por doce 12 meses a partir de la fecha de instalaci n o dieciocho 18 meses a partir de la fecha de fabricaci n cualquiera se cumpla primero Todo comerciante que considere que existe lugar a un reclamo de garant a deber ponerse en contacto con el distribuidor autorizado de Goulds Water Technology del cual adquiriera la bomba y ofrecer informaci n detallada con respecto al reclamo El distribuidor est autorizado a liquidar todos los reclamos por garant a a trav s del Departamento de Servicios a Clientes de Goulds Water Technology La presente garant a excluye a La mano de obra el transporte y los costos relacionados en los que incurra el comerciant
20. imer T Loctite Producto N 74756 disponible en las tiendas de partes automotrices y ferreter as y d jelo secar Lubrique el ensanchamiento de la caja de succi n 21 y el buje de caucho del asiento del nuevo sello estacionario con aceite liviano o agua jabonosa y emp jelo al interior del ensanchamiento en forma perpendicular y pareja PRECAUCI N No estropee ni contamine la cara pulida del asiento del nuevo sello mec nico Con el motor en posici n vertical monte nueva mente la caja de succi n adaptador sobre el motor Aseg rese de que el eje del motor no desplace el asiento estacionario del nuevo sello mec nico 10 11 Aplique una capa delgada de aceite liviano o agua jabonosa a la superficie exterior de la camisa acopla miento y al di metro interior de la parte de caucho del nuevo componente del sello giratorio Deslice el ret n del resorte el resorte y el com ponente giratorio del nuevo sello mec nico ase gur ndose de que la cara del sello permanezca en el collar de retenci n y que el ret n del resorte est asentado en forma perpendicular contra el reborde de la camisa acoplamiento PRECAUCI N Tenga cuidado para evitar da ar o ensuciar las caras pulidas del nuevo sello mec nico Recubra las roscas del eje del motor con Loctite 271 Atornille la camisa acoplamiento del eje con la parte giratoria del sello mec nico en posici n sobre el eje rosca
21. ompe Enlever les boulons d ancrage du moteur Enlever l anneau lastique 1 de l arbre par l orifice de la t te de refoulement 2 Chauffer chaque extr mit du corps de pompe 9 au chalumeau pour en amollir et d coller l enduit d tanch it des filets int rieurs Nh up ON 7 l aide de deux cl s d visser en sens antihoraire la 10 11 12 13 14 15 t te de refoulement et le corps d aspiration 21 d avec le corps de pompe Il est possible que le corps de pompe reste fix la t te de refoulement ou au corps d aspiration En pareil cas utiliser un serre tubes sangle sur le corps de pompe pour le d visser AT ne pas employer une cl tubes car cela endommagerait le corps de pompe Chauffer les filets au chalumeau pour en d coller l enduit d tanch it Retirer la chemise d arbre 4 de l ensemble accouple ment arbre 10 On peut maintenant retirer les tages compos s d un corps d tage cuvette d une roue et d un diffu seur Enlever l obturateur de l extr mit d arbre de moteur pour acc der la fente de l arbre Chauffer l ensemble accouplement chemise d arbre au chalumeau par l orifice du corps d aspiration afin d en d coller l enduit frein pour filets LoctiteMP et de d visser sens antihoraire et d enlever l ensemble ter l arbre y compris l l ment mobile de la garni ture m canique 20 en le d vis
22. or leasing pumps to customers 3 Customer means any entity who buys or leases the subject pumps from a dealer The customer may mean an individual partnership corporation limited liability com pany association or other legal entity which may engage in any type of business THIS WARRANTY EXTENDS TO THE DEALER ONLY Xylem yen 2881 East Bayard Street Ext Suite Seneca Falls NY 13148 Phone 800 453 6777 Fax 888 322 5877 www xyleminc com brands gouldswatertechnology Goulds is a registered trademark of Goulds Pumps Inc and is used under license 2012 Xylem Inc 1M023 Rev 3 February 2012 MANUAL DE LA INSTRUCCI N 4023 Modelo 45HB 70HB BOMBA REFORZADORA CENTR FUGA DE ETAPAS M LTIPLES MANUAL DE INSTALACI N OPERACI N Y RESOLUCI N DE PROBLEMAS WATER TECHNOLOC 4 GOU LDS 8 3 xylem brand INFORMACI N GENERAL Los modelos 45HB y 70HB son bombas reforzadoras centr fugas de uso general de alta presi n y de etapas m ltiples que utilizan impulsores cerrados Se utilizan en aplicaciones de l quidos transparentes no peligrosos en servicios industriales generales de hasta 180 F 82 C Especialmente convenientes para servicios de refuerzo de alta presi n Todos los modelos son de acoplamiento cerrado a mo tores el ctricos que contienen cojinetes prelubricados dise ados para un servicio continuo La extensi n de eje roscado est protegida con una com binaci n de cami
23. oso y suave pero se recomienda instalar una montura de caucho sobre los cimientos susceptibles a los efectos sonoros Alineaci n El alineamiento fino no es necesario ya que las bombas son de acoplamiento cerrado Tuber as La tuber a de succi n debe ser al menos del mismo tama o que la conexi n de succi n de la bomba y proveer carga de succi n positiva presi n de entrada a la bomba Evite usar la bomba para aplicaciones que requieran elevaci n de succi n Nunca use una v lvula de compuerta en la tuber a de succi n para estrangular la bomba PRECAUCI N La tuber a no debe aplicar esfuerzo sobre el extremo de l quido Cableado La fuente de energ a el ctrica debe ser un cir cuito derivado separado equipado con los arrancadores 6 fusibles o cortacircuitos apropiados alambre de tama o adecuado etc y debe cumplir con los c digos el ctricos nacionales y locales La tensi n la fase y los controles de la fuente de alimentaci n deben coincidir con los requerimientos indicados en la placa de identificaci n del motor Se recomienda incluir protecci n contra la baja tensi n y las p rdidas de fase tres fases Motores Los motores monof sicos de 3 HP son de doble tensi n 115 230 voltios 60 Hz de C A Los motores monof sicos de 5 HP son de 230 voltios 60 Hz C A Todos los dem s motores son trif sicos de doble tensi n 230 460 voltios 60 Hz de C A Se recomiendan las tensiones m s altas
24. plies to all water systems pumps manufactured by Goulds Water Technology Any part or parts found to be defective within the warranty period shall be replaced at no charge to the dealer during the warranty period The warranty period shall exist for a period of twelve 12 months from date of installation or eighteen 18 months from date of manufacture whichever period is shorter A dealer who believes that a warranty claim exists must contact the authorized Goulds Water Technology distributor from whom the pump was purchased and furnish complete details regarding the claim The distributor is authorized to adjust any warranty claims utilizing the Goulds Water Technology Customer Service Department The warranty excludes Labor transportation and related costs incurred by the dealer Reinstallation costs of replacement equipment a b Reinstallation costs of repaired equipment d Consequential damages of any kind and e Reimbursement for loss caused by interruption of service For purposes of this warranty the following terms have these definitions 1 Distributor means any individual partnership corporation association or other legal relationship that stands between Goulds Water Technology and the dealer in pur chases consignments or contracts for sale of the subject pumps 2 Dealer means any individual partnership corporation association or other legal relationship which engages in the business of selling
25. rificio de descarga inferior Instale una grasera limpia en el orificio superior y agregue grasa con una pistola de engrase de baja presi n Haga funcionar el motor durante 30 minutos Detenga el motor y quite la grasa drenada Reinstale todos los tapones PRECAUCI N No engrase en exceso DESARMADO Apague todo el suministro el ctrico Drene el sistema Desconecte las tuber as Quite los pernos que sujetan el motor al cimiento QQ Retire el anillo de resorte del eje 1 dentro del ca bezal de descarga 2 6 Utilice un soplete en ambos extremos de la carcasa para desintegrar el sellador de las roscas de la car casa 7 10 11 12 13 14 15 Utilice llaves en la caja de succi n 21 y en el cabezal de descarga 2 para destornillar en sentido con trahorario el cabezal de descarga y la carcasa La carcasa est roscada en el interior de cada extremo y est sellada con sellador de roscas La carcasa podr a desprenderse con el cabezal de descarga o permanec er sobre la caja de succi n Si la carcasa permanece sobre la caja de succi n puede ser retirada con una llave de banda PRECAUCI N No utilice una llave para tubos en la carcasa o se producir n da os El sellador de roscas restante puede quitarse aplicando calor con un soplete Retire la camisa del eje 4 del eje Ahora pueden retirarse las etapas cada una de las cuales consta de una copa un impulsor y
26. s de rota tion en intervertissant deux 2 conducteurs d alimentation du moteur ATTENTION ne pas faire fonctionner la pompe en sens antihoraire car cela endommagerait la pompe UTILISATION Remplir la conduite d aspiration et la pompe avec le liq uide pomper pour s assurer que la garniture m canique sera bien lubrifi e Une fois la conduite et la pompe pleines et le moteur c bl et connect correctement on peut mettre la pompe en marche S assurer qu aucun robinet n emp che la circulation du liquide dans la conduite de refoulement ENTRETIEN Lubrification L appareil ne devrait n cessiter aucun entretien sauf pour les roulements du moteur En service dur et haute temp rature lubrifier les roulements tous les trois 3 mois Suivre le calendrier de graissage recommand par le fabricant du moteur Graisser les roulements quand le moteur est chaud apr s en avoir d abord coup le courant Enlever les bouchons sup rieur et inf rieur des orifices de graissage de chaque roulement puis d barrasser les orifices inf rieurs des r sidus de graisse durcie Poser un grais seur sur l orifice sup rieur et y injecter la graisse basse pression Faire fonctionner le moteur pendant 30 min puis l arr ter et enlever la graisse sortie des roulements Reposer tous les bouchons ATTENTION ne pas mettre trop de graisse D MONTAGE Couper le courant Vidanger le syst me S parer la tuyauterie d avec la p
27. sa acoplamiento de acero inoxidable Todos los modelos est n equipados con sellos para eje mec nicos desbalanceados individuales Las unidades son enviadas completamente armadas y listas para la instalaci n IMPORTANTE 1 Inspeccione la unidad para determinar si result da ada durante el env o 2 Lea cuidadosamente todas las instrucciones 3 SIEMPRE desconecte todo el suministro el ctrico cuando maneje la bomba el motor o los controles 4 No haga funcionar la unidad en seco o contra una descarga cerrada Esto producir da os al sello mec nico y a la bomba 5 Nunca bombee solventes o l quidos peligrosos 6 Temperatura m xima del l quido 180 82 C 7 Presi n m xima de entrada 100 lbs pulg cuadrada INSTALACI N Ubicaci n Sit e la bomba lo m s cerca posible a la fuente de l quido Deje un espacio adecuado para el mantenimiento y la ventilaci n Proteja la unidad contra los da os causados por la congelaci n en tiempo fr o y el agua de lluvia o inundaci n La bomba puede montarse horizontal o vertical con el motor sobre el extremo su perior siempre que se utilice una pantalla contra goteos para proteger el motor Cimiento La superficie del cimiento debe ser plana de manera que no se produzca deformaci n o esfuerzo al apretar los pernos de cimentaci n PRECAUCI N Ni el empernado ni las tuber as deben aplicar esfuerzo sobre el extremo del l quido Las bombas son de funcionamiento silenci
28. sant sens antihoraire avec une cl de po et en bloquant l arbre de moteur avec un tournevis ins r dans la fente de celui ci Nota tant donn que l on a chauff l arbre donc la gar niture m canique on doit jeter celle ci et la remplacer par une garniture neuve D poser les vis de fixation 23 de l adaptateur de moteur 22 Enlever l ensemble corps d aspiration adaptateur de moteur Placer l ensemble corps d aspiration adaptateur de moteur sur une surface plane et pousser l l ment fixe de la garniture m canique hors de son logement au centre du corps d aspiration REMONTAGE L 2 Je 4 Nettoyer toutes les pi ces et surtout les surfaces de guidage moteur pompe les surfaces du logement de garniture m canique corps d aspiration et l arbre particuli rement l paulement pour l ensemble accouplement chemise d arbre Nettoyer les filets de l arbre de moteur et de l ensemble accouplement chemise d arbre et en enlever l enduit Loctite avec une brosse en m tal Appliquer de l appr t Primer TM de Locquic produit Loc titeM n 74756 vendu dans les magasins de pi ces d automobile et les quincailleries sur les filets et le laisser s cher Lubrifier les surfaces du logement de garniture m ca nique et la bague en caoutchouc de l l ment fixe de la garniture avec une huile l g re ou de l eau savonneuse puis pousser l l ment fixe uniform ment jusqu au fond du logement ATTENTION
29. tor to foundation 5 Remove shaft snap ring 1 within discharge head 2 6 Use a torch on both ends of casing to break down thread sealant at casing threads 7 Use wrenches on suction housing 21 and discharge head 2 to unscrew counter clockwise discharge head and casing Casing is threaded inside each end and sealed with thread sealant The casing may come off with the discharge head or stay on the suction housing If the casing remains on the suction housing it may be removed with a strap wrench CAUTION Do Not use a pipe wrench on the casing or dam age will result The unbroken thread sealant may be removed by applying heat with a torch 8 Remove shaft sleeve 4 from shaft 9 Stages each consisting of a bowl impeller and dif fuser can now be removed 10 11 12 13 14 15 Remove motor end plug to expose slot in end of mo tor shaft Heat shaft sleeve coupling with a torch by directing a flame through hole in suction housing 21 This will break down Loctite thread locking compound to allow removal of the sleeve coupling NOTE Thread is right hand Turn counter clockwise to loosen Remove shaft assembly including rotating portion of mechanical seal by holding motor shaft with a screw driver in motor shaft slot while turning pump shaft assembly counter clockwise with a wrench NOTE Due to the applied heat the mechanical seal must be discarded and replaced with a new mechani cal s
30. un difusor Quite el tap n del extremo del motor para dejar al descubierto la ranura en el extremo del eje del motor Caliente la camisa acoplamiento del eje con un soplete dirigiendo la llama a trav s del agujero en la caja de succi n 21 Esto desintegrar el compuesto fijador de roscas Loctite para permitir retirar la camisa acoplamiento Nota La rosca es de mano derecha Gire en sentido contrahorario para aflojar Retire el conjunto del eje incluso la parte giratoria del sello mec nico sujetando el eje del motor con un destornillador en la ranura del eje mientras gira el conjunto del eje de la bomba en sentido contraho rario con una llave de 1 2 pulg Nota Debido al calor aplicado el sello mec nico debe ser desechado y reemplazado con uno nuevo Quite los pernos que sujetan el adaptador al motor Retire la combinaci n de caja de succi n adaptador del motor Coloque la caja de succi n adaptador sobre una su perficie plana y empuje hacia afuera la parte estacio naria del sello mec nico REARMADO 1 Limpie todas las partes especialmente los encajes de registro del motor el ensanchamiento del asiento del sello en la caja de succi n y el eje especialmente donde la camisa acoplamiento del eje calza contra el reborde del eje Limpie las roscas de la camisa acoplamiento del eje y las roscas del eje del motor Limpie el Loctite viejo de las roscas con un cepillo de alambre Aplique Locquic Pr