Ventilation Fan MODELS: 671R & 672R

image

Contents

1. 120 V CA 60 Hz DUCT COLLAR COLLIER DE GAINE COLLAR N DEL TUBO 2 LENGUETA DE MONTAJE WIRING KNOCKOUT OUVERTURES PREAMORCEES AGUJERO CIEGO DE CABLEADO HANGER BARS SOLD SEPARATELY BARRES DE SUSPENSION VENDUES SEPAREMENT BARRAS DE SUSPENSION SE VENDEN POR SEPARADO GREEN GROUND LEAD VIS VERTE DE MISE A LA TERRE HILO VERDE DE CONEXI N A TIERRA l BO TE D INTERRUPTEUR l SWITCH BOX l l CAJA DEL INTERRUPTOR l FIELD GROUNDING WIRE FIL DE MISE LA TERRE HILO DE CONEXI N A TIERRA FIGURE 4 POWER BLOWER UNIT INSTALLATION 1 Place power blower unit into housing so that mounting plate s tabs insert into slots in housing 2 Press other end of mounting plate down until it is firmly seated over scroll and plug in receptacles 3 Secure mounting plate to housing with provided screw 4 Refer to Figure 5 Insert motor plug into junction box receptacle GRILLE INSTALLATION 1 Refer to Figure 6 Squeezing grille s mounting springs together insert springs into slots on both sides of the housing 2 Press grille firmly into place against ceiling INSTALLATION IN EXISTING CONSTRUCTION Note Installation in a finished house requires at least a small accessible area attic or crawl space above the planned installation location 1 After determining desired location for fan drill a small hole in the ceiling Place a coat hanger or other stiff wire up through
2. d Enlever la plaque en tirant ses pattes hors des fentes du boitier Mettre le moteur de c t 2 Enlever une des ouvertures pr amorc es pour le c blage MONTAGE DU BO TIER Utilisation des fixations de montage Voir Figure 2 1 Positionner le bo tier a c t d une traverse de plafond 2 Utiliser des vis bois non fournies afin de fixer librement le boitier sur une traverse du plafond au moyen des fentes des fixations de montage 3 Ajuster le boitier afin de le positionner au ras du plafond fini 4 Lorsque l habitacle est bien positionn visser les vis des fentes Utilisation de barres de suspension Les barres de suspension sont vendues s par ment commander le mod le HB4 Voir Figure 3 1 Ins rer les barres de suspension dans les fentes situ es sur le boitier 2 Positionner le bo tier de ventilation entre les traverses du plafond afin que le dessous du boitier du ventilateur soit au ras du plafond fini 3 Utiliser des vis ou des clous pour fixer les supports de montage sur les traverses du plafond INSTALLATION DES CONDUITS 1 Voir Figure 2 Placer le collier de conduit sur les collerettes l ouverture d vacution du ventilateur Fixer le collier en pressant les pattes dans les fentes des collerettes 2 Faire passer un conduit rond de 10 cm 4 po de l ouverture d vacuation du ventilateur l ext rieur 3 Raccorder le conduit au collier de conduit du ventilateur C BLAGE
3. Tout le c blage doit respecter les reglements locaux et le ventilateur doit tre convenablement reli a la terre 1 Amener un c ble de 120 V CA avec fil de terre de l interrupteur mural l emplacement du ventilateur 2 Tirer le c ble par le trou d acc s jusque dans la bo te de jonction 3 Voir Figure 4 Utiliser des connecteurs agr s pour raccorder les c bles d alimentation g n rale aux fils de l appareil le blanc avec le blanc le noir avec le noir Raccorder le fil de terre vert ou nu a la vis verte de mise la terre INSTALLATION DU MOTEUR 1 Placer le moteur dans le bo tier de sorte que les pattes de la plaque de montage s ins rent dans les fentes du boitier 2 Apuyer sur l autre extr mit de la plaque de montage pour la faire descendre jusqu a ce qu elle soit bien install e au dessus du rebord et des prises de branchement 3 Visser la plaque de montage au boitier 4 Voir Figure 5 Ins rer la fiche du moteur dans la prise de la boite de jonction INSTALLATION DE LA GRILLE 1 Voir Figure 6 En comprimant les ressorts de montage de la grille les ins rer dans les fentes des deux c t s du boitier 2 Appuyer fermement sur la grille pour qu elle vienne contre le plafond INSTALLATION DANS UNE CONSTRUCTION EXISTANTE Remarque L installation dans une maison d ja termin e demande au moins un petit espace accessible au dessus du lieu d installation choisi grenier ou comble
4. de la mani re pr vue par le fabricant Pour toute question communiquer avec le fabricant Avant de faire l entretien ou le nettoyage de couper le courant au panneau lectrique et verrouiller ce dernier pour viter que le courant ne soit remis accidentellement Si Pinterrupteur ne peut tre verrouill placer un avertissement clairement visible par exemple une tiquette sur le panneau lectrique ATTENTION Cet appareil ne doit servir qu a la ventilation g n rale Ne pas l utiliser pour l vacuation de mati res ou de vapeurs dangereuses ou explosives AVERTISSEMENT Pour r duire les risques d incendie ou de choc lectrique ne pas utiliser de commande lectronique de vitesse avec ce ventilateur DIRECTIVES D INSTALLATION AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOC LECTRIQUE OU DE BLESSURES RESPECTER CE QUI SUIT A Les travaux d installation et d lectricit doivent tre confi s a des personnes qualifi es conform ment aux normes et aux codes en vigueur notamment en ce qui concerne les normes de protection contre les incendies B Pour viter les retours d air les appareils de chauffage doivent avoir suffisamment d air pour assurer une combustion et une vacuation appropri es des gaz Suivre les directives du fabricant de de chauffage ainsi que les normes de s curit dict es par des organismes comme la National Fire Protection Associat
5. finished ceiling surface 4 When housing is properly adjusted tighten screws in slots Mounting Using Hanger Bars hanger bars sold separately order model HB4 Refer to Figure 3 1 Insert hanger bars in slots provided in housing 2 Locate fan housing between joists so that the bottom of the housing is even with the planned finished ceiling Extend the hanger bars to the joists 3 Use screws or nails not provided to secure hanger bars to ceiling joists INSTALLING DUCTWORK 1 Refer to Figure 2 Place duct collar over flanges at discharge opening of fan Secure collar by snapping tabs into slots in flanges 2 Run 4 round duct from outside to fan s discharge opening 3 Connect duct to fan s duct collar WIRING All wiring must comply with local codes and unit must be properly grounded 1 Run 120vAC house wiring with ground from wall switch to fan location 2 Pull wire through access hole and into junction box 3 Refer to Figure 4 Use approved wire nuts to connect house supply wires to fixture as follows white to white black to black Connect green or bare ground wire to green ground lead FLANGES COLLERETTES BRIDAS JUNCTION BOX BO TE DE JONCTION CAJA DE CONEXIONES STANDARD WALL SWITCH NOT INCLUDED INTERRUPTEUR MURAL STANDARD NON INCLUS INTERRUPTOR DE PARED ESTANDAR NO SE INCLUYE 120vAC 60Hz HOUSE POWER COURANT DOMESTIQUE 120V CA 60 Hz ELECTRICIDAD DOM STICA
6. la etapa preliminar de instalaci n de la estructura de la construcci n La unidad del soplador y la rejilla deben instalarse despu s de que est en su sitio el techo terminado Para instalar el ventilador de extracci n en una construcci n finalizada se requiere un rea accesible sobre el lugar de instalaci n deseado tico o espacio entresuelos INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS EL CTRICAS O LESIONES PERSONALES OBSERVE LAS SIGUIENTES INDICACIONES A Use la unidad s lo de la manera indicada por el fabricante Si tiene preguntas comun quese con el fabricante B Antes de dar servicio o limpiar la unidad interrumpa el suministro el ctrico en el panel de servicio y bloquee el panel de servicio para evitar que la electricidad se active accidentalmente Cuando no sea posible bloquear los medios de desconexi n del servicio fije firmemente una se al de advertencia tal como una etiqueta en un lugar visible del panel de servicio PRECAUCI N S lo para usarse como medio de ventilaci n general No debe usarse para la extracci n de materiales ni vapores peligrosos o explosivos ADVERTENCIA Para reducir el riesgo de incendio o de descargas el ctricas no use este ventilador con ning n dispositivo de control de velocidad de estado s lido INSTRUCCIONES DE INSTALACI N ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS EL CTRICAS O LE
7. Nulone Ventilation Fan MODELS 671R amp 672R The Exhaust Fan consists of the housing power unit blower assembly motor wheel mounting plate grille and duct collar FAN MUST NOT BE INSTALLED IN A CEILING INSULATED TO A VALUE GREATER THAN R 40 SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT FOR BEST RESULTS When installing the Exhaust Fan in a new construction site install the housing during the rough in construction The blower unit and grille should be installed after the finished ceiling is in place To install the Exhaust Fan in an existing finished building an accessible area is required above the planned location attic or crawl space IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING To reduce the risk of fire or electric shock do not use this fan with any soli
8. R TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of reque
9. SIONES PERSONALES OBSERVE LAS SIGUIENTES PRECAUCIONES A Una o m s personas calificadas deben realizar el trabajo de instalaci n y el cableado el ctrico de acuerdo con todos los c digos y normas correspondientes incluso los c digos y normas de construcci n espec ficos para incendios B Se necesita suficiente aire para que se lleve a cabo una combusti n adecuada y la descarga de los gases a trav s del tubo de humos chimenea del equipo quemador de combustible a fin de evitar las contracorrientes Siga las directrices y las normas de seguridad del fabricante del equipo de calentamiento tales como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y los c digos de las autoridades locales C Al cortar o perforar a trav s de la pared o del techo tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos D Los ventiladores entubados deben siempre conectarse hacia el exterior E Si se va a instalar esta unidad sobre una tina o ducha debe estar marcada como apropiada para esta aplicaci n y conectarse a un GFCI interruptor accionado por p rdida de conexi n a tierra en un circuito de derivaci n protegido F No coloque NUNCA un interruptor en un lugar alcanzable
10. SPOSITIFS D AMORCAGE NI LES TUBES DES LUMINAIRES FLUORESCENTS Cette garantie ne couvre pas a l entretien et le service courants ni b les produits et les pi ces ayant fait l objet du n usage abusif de n gligence d un accident d un entretien ou d une r paration non appropri e par du personnel autoris par Broan NuTone d une mauvaise installation ou d une installation non conforme aux directives d installation fournies La dur e de toute garantie implicite est limit e la p riode de deux ans pr cis e pour la garantie expresse Certains tats ne reconnaissent pas les restrictions relatives la dur e des garanties implicites il se pourrait donc que cette restriction ne s applique pas dans votre cas LE REMPLACEMENT OU LA REPARATION PAR BROAN NUTONE A SA PROPRE DISCRETION DE TOUT PRODUIT OU PIECE DEFECTUEUX CONSTITUE LE SEUL REMEDE DE L ACHETEUR EN VERTU DE CETTE GARANTIE BROAN NUTONE NE PEUT ETRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONSECUTIFS OU SPECIAUX ATTRIBUABLES A UTILISATION OU AU RENDEMENT DU PRODUIT Certains tats ne reconnaissent pas les restrictions ni les exclusions relatives aux dommages indirects cons cutifs ou sp ciaux il se pourrait donc que cette restriction ne s applique pas dans votre cas La pr sente garantie vous accorde des droits sp cifiques mais vous pourriez aussi avoir d autres droits en fonction de l tat dans lequel vous r sidez Cette garantie remplace toute autre
11. connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit F NEVER place a switch where it can be reached from a tub or shower PLANNING DUCTWORK AND WIRING Ductwork 1 Use 4 round duct 2 Plan to run duct from discharge opening of fan to the outside For best fan performance make the duct run as short as possible and use a minimum number of elbows 3 Use optional ducting accessories as required Wiring Plan to run 120vAC house wiring with ground from the power source through a standard wall switch Preparation 1 Refer to Figure 1 Remove blower power unit assembly from the housing a Unplug the power unit b Remove the screw located next to plug in receptacle which holds blower power unit mounting plate in place Do not misplace this screw c Lift the mounting plate at the end near the plug in receptacle until blower wheel clears the scroll d Remove plate by pulling its tabs out of slots in the housing Set blower power unit aside until needed 2 Remove one of the wiring knockouts from housing MOUNTING THE HOUSING Mounting Using Mounting Tabs Refer to Figure 2 1 Locate fan housing next to ceiling joist 2 Using wood screws not provided loosely attach the housing to ceiling joist through the keyhole slots in mounting tabs 3 Adjust housing so that it will be flush with the finished ceiling For the grille to fit properly the housing s rim must not extend beyond
12. d state speed control INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities TO REGISTER THIS PRODUCT VISIT WWW NUTONE COM READ 8 SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS DUCT COLLAR COLLIER DE GAINE COLLAR N DE TUBO HOUSING BOITER CUBIERTA MOUNTING TAB PATTES DE MONTAGE LENGUETA DE MONTAJE SLOTS FENTES RANURAS POWER UNIT BLOWER ASSEMBLY ENSEMBLE MOTEUR VENTILATEUR CONJUNTO DE UNIDAD DE POTENCIA SOPLADOR tass LT LENGUETA REJILLA C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be
13. damente 1 Tienda el cableado de 120 V CA dom stico con conexi n a tierra desde el interruptor de pared hasta la ubicaci n del ventilador 2 Pase el cable por el orificio de acceso y hacia la caja de conexiones 3 Consulte la figura 4 Con tuercas para cables aprobadas conecte los cables de alimentaci n de la casa al dispositivo de la siguiente manera blanco a blanco negro a negro Conecte el cable verde o cable de tierra desnudo al hilo verde de conexi n a tierra INSTALACI N DEL CONJUNTO DE UNIDAD DE POTENCIA SOPLADOR 1 Coloque la unidad de potencia soplador en la cubierta de manera que las leng etas de la placa de montaje se inserten en las ranuras de la cubierta 2 Presione el otro extremo de la placa de montaje hasta asentarla firmemente sobre la espiral y los recept culos enchufables 3 Fije la placa de montaje a la cubierta con el tornillo suministrado 4 Consulte la figura 5 Inserte el enchufe del motor en el recept culo de la caja de conexiones INSTALACI N DE LA REJILLA 1 Consulte la figura 6 Comprima entre s los resortes de montaje de la rejilla e introd zcalos en las ranuras de ambos lados de la cubierta 2 Presione la rejilla firmemente hasta que encaje en su sitio en el techo INSTALACI N EN CONSTRUCCIONES EXISTENTES Nota Para instalar el ventilador en una casa terminada es necesario disponer como m nimo de una peque a rea accesible sobre el lugar de instalaci n d
14. desde una tina o ducha PLANIFICACI N DEL SISTEMA DE TUBER A Y CABLEADO Sistema de tuber a 1 Utilice un tubo redondo de 4 pulgadas 10 cm 2 Planee pasar el tubo desde la abertura de descarga del ventilador al exterior Para conseguir el mejor rendimiento del ventilador haga el tramo de tuber a lo m s corto posible y con el menor n mero de codos necesario 3 Si es necesario utilice accesorios de tuber a opcionales Cableado Planifique hacer pasar el cableado de 120 V CA de la casa con conexi n a tierra desde la fuente de alimentaci n a trav s de un interruptor de pared Preparaci n 1 Consulte la figura 1 Retire el conjunto del soplador unidad de potencia de la cubierta a Desenchufe la unidad de potencia b Saque el tornillo situado al lado del recept culo enchufable que sostiene la placa de montaje del conjunto de unidad de potencia soplador en su sitio No pierda el tornillo c Levante la placa de montaje en el extremo cerca del recept culo enchufable hasta que la rueda del soplador se separe de la espiral d Quite la placa tirando de las leng etas para sacarlas de la cubierta Ponga aparte el conjunto de unidad de potencia soplador hasta que lo necesite 2 Quite uno de los agujeros ciegos de cableado de la cubierta MONTAJE DE LA CUBIERTA Montaje con las leng etas de montaje Consulte la figura 2 1 Coloque la cubierta del ventilador junto a la vigueta del techo 2 Con
15. eseado tico o espacio entresuelos 1 Una vez elegida la zona donde se instalar el ventilador perfore un peque o orificio en el techo Meta un gancho de ropa u otro alambre r gido por el orificio para ayudar a encontrarlo desde arriba 2 Coloque la cubierta del ventilador en la parte superior de la superficie del techo y utilice la cubierta como una plantilla para marcar el rea que se va a cortar 3 Una vez hecho el corte coloque la cubierta en la abertura mediante las barras de suspensi n se venden aparte o m ntela directamente en la vigueta mediante las leng etas de montaje A Inserte las barras de suspensi n en las ranuras de la cubierta B Coloque la cubierta en la abertura cuidando de que la parte inferior de la cubierta quede al ras con el techo C Fije las barras de suspensi n a las viguetas de techo con tornillos o clavos no se suministran D Finalice la instalaci n siguiendo las indicaciones anteriores GARANT A Garantia Limitada de un A o GARANT A DEL PROPIETARIO Broan NuTone garantiza al comprador consumidor original de sus productos por el per odo de un 1 a o desde la fecha original de compra que tales productos est n libres de defectos en material y mano de obra NO HAY OTRAS GRANT AS EXPRESADOS O SOBREENTENDIDAS INCLUYENDO PERO NO LIMITADAS A GRANT AS NO EXPRESADAS DE MERCHNTIBILIDAD O ADAPTABLES A UN PROP SITO EN PARTICULAR Durante este per odo de un a o Broan NuTone
16. garantie donn e pr c dement SERVICE SOUS GRANTIE Pour tre admissible au service sous garantie vous devez a aviser Broan NuTone l adresse ou au num ro de t l phone ci dessous b fournir le num ro du mod le et la description de la pi ce et c d crire la nature d faut de la pi ce ou du produit Au moment de la demande de service sous garantie vous devez fournir une preuve de la date d achat originale Date d installation Entrepeneur ou installateur N de mod le et description du produit POUR OBTENIR DE L ASSITANCE OU DU SERVICE CONTACTEZ Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 Broan NuTone Canada Mississauga Ontario www nutone ca 877 896 1119 Rev 08 2007 Nulone LEA Y CONSERVE ESTAS INSTRUCCIONES INSTRUCCIONES DE INSTALACION Ventilador de ventilaci n MODELOS 671R Y 672R El ventilador de extracci n consta de los siguientes componentes cubierta conjunto de unidad de potencia soplador motor rueda placa de montaje rejilla y collar n de tubo NO SE DEBE INSTALAR EL VENTILADOR EN UN TECHO QUE TENGA UN VALOR DE AISLAMIENTO SUPERIOR A R 40 SE PUEDE INSTALAR ESTE PRODUCTO SOBRE UNA DUCHA O TINA SIEMPRE QUE SE CONECTE A UN CIRCUITO SECUNDARIO PROTEGIDO POR UN GFCI INTERRUPTOR ACCIONADO POR P RDIDA DE CONEXI N A TIERRA PARA LOGRAR RESULTADOS PTIMOS Cuando vaya a instalar el ventilador de extracci n en una construcci n nueva monte la cubierta durante
17. hole to help in locating from above 2 Place fan housing on top of ceiling surface and use the housing as a template to mark area to be cut out 3 After cutting out opening mount housing in the opening using the hanger bars sold separately or mount directly to joist using mounting tabs A Insert hanger bars in slots in housing B Position housing in opening so that bottom of housing is flush with ceiling C Use screws or nails not provided to secure hanger bars to ceiling joists D Complete installation as described above INSERT TABS INTO SLOTS INSERER LES PATTES DANS LES FENTES INSERTAR LENGUETAS EN LAS RANURAS FIGURE 5 MOUNTING SPRINGS RESSORTS DE MONTAGE RESORTES DE MONTAJE SLOTS FENTES RANURAS GRILLE GRILLE REJILLA FIGURE 6 WARRANTY One Year Limited Warranty WARRANTY OWNER Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS O
18. hos legales especificos y Ud puede tener otros derechos los cuales var an de estado a estado Esta garantias reemplaza a todas las garant as anteriores SERVICO DE GARANT A Para tener derecho al servicio de garant a Ud debe a Notificar a Broan NuTone a la direcci n o el n mero de tel fono abajo b indicar el n mero de modelo y la identifaci n de la party y c describir la naturaleza de cualquier defecto en la producto o parte Al momento de solicitor el servicio por la garant a Ud debe presentar la evidencia de la fecha original de compra Fecha de la instalaci n Constructor o instalador N mero de modelo y descripci n del producto SI NECESITA ASISTENCIA O SERIVIVIO CONTACTO Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 Broan NuTone Canada Mississauga Ontario www nutone ca 877 896 1119 Rev 08 2007 10 SERVICE PARTS Models 671R 672R DESCRIPTION MOTOR MOUNTING PLATE MOTOR ISOLATION MOUNT GROUND CLIP MOTOR 671R 97 MOTOR 672R BLOWER WHEEL 6 30652000 DUCT ADAPTER ASSEMBLY GRILLE SPRING 2 REQ 8 97017607 GRILLE ASSEMBLY INCLUDES GRILLE SPRINGS Co oo RECEPTACLE ET POWER UNITASSEMBLY G72R Nulone Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 11 12 99044124B
19. ion NFPA l American Society for Heating Refrigeration and Air Conditioning Engineers ou les organismes de r glementation locaux C Lorsque les murs et plafonds sont perc s viter d endommager les fils lectriques et les autres canalisations D Les ventilateurs dot s de conduits doivent toujours tre raccord s l ext rieur E Si cet appareil doit tre install au dessus d une baignoire ou d une cabine de douche il doit tre identifi comme convenant une telle installation F NE JAMAIS placer un interrupteur la port e d une personne qui se trouverait dans la baignoire ou la douche PR PARATION DES CONDUITS ET DU C BLAGE Conduits 1 Utiliser un conduit rond de 10 cm 4 po 2 Pr voir le parcours des conduits pour vacuation l ext rieur Pour de meilleures performances s arranger pour que le conduit soit aussi court que possible et utiliser un minimum de coudes 3 Utiliser les accessoires de conduit NuTone en option C blage Amener un c ble de 120 V CA avec terre de la source de courant en passant par un interrupteur mural standard Pr paration 1 Voir Figure 1 Enlever le moteur du boitier a D brancher le moteur b Enlever et conserver la vis plac e pr s de la prise de branchement qui retient la plaque de montage du moteur en place c Soulever la plaque de montage du c t de la prise de branchement jusqu ce que les aubes du ventilateur d gagent le rebord
20. reparar o reemplazar a su opci n y sin costo cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio ESTA GARANT A NO CUBRE A LOS ARRANCADORES PARA L MPARAS FLUORESCENTES 0 A LOS TUBOS FLUORESCENTES FILTROS DUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA CANALIZACI N Esta granat a no cubre a Mantenimiento y servicios normales b Productos 0 partes sujetos al mal uso negligencia accidente mantenimiento inadecuado o reparaciones port otros ajenos a Broan NuTone instalaci n defectusoa o a una instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garantia no expresada est limitada a un periodo de un a o seg n se especifica en la garantia expresada Algunos estados no permiten limitaci n en cuanto a la duraci n de una grantia no expresada por lo que la limitaci n arriba indicada puede que no se apliqu a Ud LA OBLIGACI N DE BROAN NUTONE DE REPARAR 0 REEMPLAZAR A SU OPCI N SER EL NICO Y EXCLUSIVO RECURSO QUE TENDR EL COMPRADOR BAJO ESTA GARANT A BROAN NUTONE NO SER RESPONSABLE POR DA OS INCIDENTALES CONSECUENTES O ESPECIALES QUE RESULTEN A CONSECUENCIA O SEAN INDEPENDIENTE DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentals o consecuentes de modo que la limitaci n o exclusi n arriba indicada pueda que no se aplique a Ud Esta garantia le proporciona derec
21. s 1 Apr s avoir d termin l emplacement du ventilateur percer un petit trou dans le plafond 2 Placer le bo tier du ventilateur sur la surface du plafond et l utiliser comme gabarit pour marquer les limites de la d coupe 3 Apr s avoir fait l ouverture fixer le bo tier dans louverture en utilisant les barres de suspension vendues s par ment ou le fixer directement aux solives au moyen des fixations de montage A Introduire les barres de suspension dans les ouvertures du bo tier Positionner le bo tier dans l ouverture afin que le bas de celui ci soit au ras du plafond C Utiliser des vis ou des clous non fournies afin de fixer les barres de suspension sur les traverses du plafond D Finir l installation tel qu expliqu ci dessus GARANTIE Garantie limit e d un an GARANTIE DU PROPRI TAIRE Broan NuTone garantie l acheteur original de ses produits que ces derniers seront exmpts de tout d faut de mat riaux et de fabrication pour une p riode d un 1 an a compter de la date d acha AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONN E Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILIT OU D ADAPTATION A UN USAGE PARTICULIER Pendant cette p riode d un an Broan NuTone proc dera au remplacement ou a la r paration sans aucuns frais mais a sa propre discr tion de tout produit ou pi ce jug d fectueux dans le cadre d une utilisation normale CETTE GARANATIE NE VISE PAS LES DI
22. sting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE CONTACT Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 Broan NuTone Canada Mississauga Ontario www nutone ca 877 896 1119 Rev 08 2007 Nulone VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER INSTRUCTIONS D INSTALLATION Ventilateur de ventilation MODELES 671R et 672R Le ventilateur comprend le boitier le bloc moteur moteur aubes plaque de montage la grille et le collier de conduit LE VENTILATEUR NE DOIT PAS ETRE INSTALLE DANS UN PLAFOND A ISOLATION THERMIQUE SUPERIEURE A R 40 UTILISATION POSSIBLE AU DESSUS D UNE BAIGNOIRE OU D UNE DOUCHE LORSQUE RELIE A UN CIRCUIT PORTEGE PAR DISJONCTEUR DIFFERENTIEL POUR DE MEILLEURS RESULTATS Lors de l installation du ventilateur dans une construction neuve installer le bo ter avant de proc der aux finitions Le bloc moteur et la grille doivent tre install s apr s la finition du plafond Pour installer le ventilateur dans une construction ancienne un espace accessible au dessus de l emplacement choisi pour l installation est exig grenier ou combles IMPORTANTES DIRECTIVES DE S CURIT AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOCS LECTRIQUES OU DE BLESSURES RESPECTER CE QUI SUIT A N utiliser cet appareil que
23. tornillos para madera no se suministran fije holgadamente la cubierta a la vigueta del techo a trav s de las ranuras bocallave de las lenguetas de montaje 3 Ajuste la cubierta de tal manera que est al ras del techo acabado Para que la rejilla encaje bien el borde de la cubierta no debe extenderse m s all de la superficie acabada del techo 4 Cuando la cubierta est bien ajustada apriete los tornillos en las ranuras Montaje con barras de suspensi n las barras de suspensi n se venden por separado al hacer el pedido debe especificarse el modelo HB4 Consulte la figura 3 1 Inserte las barras de suspensi n en las ranuras de la cubierta 2 Coloque la cubierta del ventilador entre las viguetas de manera que la parte inferior de la cubierta est al ras del techo acabado Extienda las barras de suspensi n hasta las viguetas 3 Sujete las barras de suspensi n a las viguetas de techo con tornillos o clavos no se suministran INSTALACI N DEL SISTEMA DE TUBER A 1 Consulte la figura 2 Coloque el collar n del tubo sobre las bridas en la abertura de descarga del ventilador Fije el collarin encajando las leng etas en las ranuras de las bridas 2 Pase el tubo redondo de 4 pulgadas 10 cm desde la abertura de descarga del ventilador 3 Conecte el tubo al collar n de tubo del ventilador CABLEADO Todo el cableado debe cumplir con los c digos locales y la unidad debe estar puesta a tierra adecua