Home
Manual de Instalación Pulsador Manual Compacto Convencional
Contents
1. O AS O N O o gt L A i kd e Q for required resistance o EA Meldergruppe 1 Mc Detector zone E Aia a E h a E H i Du y y E MG Zone HE E La E NN O E R OE E E Bar A aa MG Zone FA O A O a e Os MD Po Da Ml Do o S Fig 10 Instalaci n en zona convencional Fig 10 Wiring of the conventional detector zone
2. 704960 Replacement glass screen 10 pieces 704960 Etiqueta transparente para impresi n de otros iconos 10 Uds 704961 Label transparent with whit printing differing from standard icons 10 pieces 704961 L mina de pl stico rearmable L 10 Uds 704964 Plastic operating panel K resettable white 10 pieces 704964 Cubierta transparente abatible O para protecci n de activaciones no intencionadas y aumento de Hinged cover N to protect the detector for unintended activation and to increase grado de protecci n IP 43 a IP 55 04965 the protection rating from IP 43 up to IP 55 04965 Llave de repuesto 10 Uds 704966 Replacement key 10 pieces 704966 Marco de monataje para pulsador compacto rojo blanco 132 x 132 x 8 mm 704967 Frame for small Manual Call Points incl cover red white 132 x 132 x 8 mm 704967 Caja de montaje en superficie rojo similar RAL 3020 704980 Back box for surface mounting red similar to RAL 3020 704980 Caja de montaje en superficie azul similar RAL 5015 704981 Back box for surface mounting blue similar to RAL 5015 704981 Instalaci n Mounting ai O X B B E CN e LO y LE l Fig 1 Dimensiones Figura 2 Apertura de la tapa carcasa Figura 3 Etiqueta de identificaci n Fig 1 Dimensions Fig 2 Open the housing seal Fig 3 Identification label Cristal Glass PG pss F G E OY TUN Indicador de Papel Paper inlay Arriba Top
3. 5 Coloque la l mina K correctamente y gire la llave en sentido contrahorario hasta el tope izquierdo M para subir la l mina Fig 6 Prueba Gire la llave C en sentido horario hasta el tope derecho L hasta que la l mina caiga y se indique la activaci n F G Fig 4 Para rearmar el equipo gire la llave en sentido contrahorario hasta el tope izquierdo M para subir la l mina Instalaci n Montaje El pulsador puede instalarse sobre caja de empotrado mecanismo est ndar 55 60mm Montaje en El pulsador se instala sobre caja de superficie Superficie opcional o con marco de montaje universal opcional Instale el Pulsador de un modo seguro en una pared apropiada sobre una superficie lisa con los tornillos y tacos adecuados Fig 7 8 Apertura Inserte la llave por sus dos patillas en los orificios inferiores de la cubierta abajo Presione hacia arriba para liberar la tapa Fig 2 Tire desde abajo hacia fuera hasta retirar la tapa Cierre Gire la llave en sentido contrahorario hasta su tope izquierdo M Fig 6 Coloque la leng eta superior de la cubierta sobre las ranuras del m dulo del pulsador y presione hasta encajar la cubierta en su posici n Abra la carcasa como se ha indicado y quite la l mina transparente de pl stico D E presionando hacia afuera coloque el pictograma adecuado en el frontal coloque de nuevo la l mina transparente sobre el nuevo pictograma y presione hasta su posic
4. ESSER by Honeywell Manual de Instalaci n Pulsador Manual Compacto Convencional Installation Instruction Electronic module Conventional MCP Ref Part No 804950 804970 798935 03 2006 Cambios t cnicos reservados CE EB gt Technical changes reserved Novar GmbH a Honeywell Company DieselstrafBe 2 D 41469 Neuss Internet www novar de E Mail info novar de CE Cuando se usa un Pulsador como pulsador de Alarma se DM debe usar una carcasa roja con una etiqueta de identificaci n con el s mbolo correcto como es mostrado en Fig 3 y 4 Cuando se usan diferentes carcasas o diferentes s mbolos el equipo est clasificado como equipo de activaci n y no como Pulsador de Alarma Observe la secuencia correcta del cableado Terminales 1 4 1 Entrada 2 Salida 3 y 4 Com n Use cable de comunicaciones claramente identificado l Y St Y n x 2 x 0 8 mm o cable para alarma de incendio La conexi n de la malla del cable debe realizarse al Terminal de tierra para evitar interferencias Se debe tener en cuenta durante el mantenimiento o labores de reparaci n la activaci n de sistemas de aviso como por ejemplo activaci n a central receptora Use junta de paso para cableado para evitar el acceso de humedad Siguiendo normas de instalaci n de VdS no es posible configurar Pulsadores y Detectores en la misma zona de Detecci n max 10 MCP por zona Si se usa el marco de montaje Ref 704967 de
5. Zy Y a A L mina rearmable Ref 704964 Plastic operating panel Part N 704964 Arriba Top LH X Figura 4 Indicacidores LED y cubiertas de Pl stico rearmable cristal y papel Figura 5 Posici n de llave para prueba extraer cristal Figura 6 Posici n de llave para rearme insertar cristal fuera de uso Fig 5 Key lock position for test mode and removing screen Fig 6 Key lock position for Reset Replace screen Fig 4 Mechanical alarm indicator and LED Glass screen paper inlay and plastic operating panel 132 N m Figura 7 Caja de montaje en superficie Ref 704980 Figura 8 Marco de montaje universal Art Nr 704967 Figura 9 Cubierta abatible Ref 704965 Fig 7 Back box for surface mounting Part No 704980 Fig 8 Universal installation incl cover Part No 704967 Fig 9 Hinged cover Part No 704965 System 8000 IQ8Control A A E A A A A Siguiente equipo o final de l nea EOL resistencia Revise la J N A N J li hi f documentaci n de la central o equipo al que conecte el N OOO LO wt NN paa KONAN j aa O ES 0 O q als pulsador para el valor del final de Di 2s l nea Next detector or End Of Line resistor R Refer to Panels manual
6. ber montarse la cubierta blanca When the MCP is used as a manual call point it must be installed in a red housing with an identification label showing the standardize conformal symbol as shown in Fig 3 4 When housings with different colours and identification labels are used the unit is classed as a manual activation device and not as a manual call point Observe the correct wiring sequence Terminals 1 4 1 IN 2 OUT 3 u 4 Use designated communication cable l Y St Y n x 2 x 0 8 mm or fire alarm cable Connection of the cable shield to the ground terminal protects the signal cables against interference The alarm activation and triggering of notifying systems e g manned centre link Master box must be observed during any Service of the MCP Install inlying cable with a dripping bend to protect the device from dampness VdS Pursuant to the VdS guidelines MCPs and automatic fire detectors must not be operated in a common detector zone max 10 MCP per detector zone By using the mounting frame Part No 704967 the white covering must be fitted Importante Se declina toda responsabilidad sobre da os derivados y garant a por no seguir estas instrucciones de instalaci n Estas instrucciones deben ser tenidas en cuenta cuidadosamente antes de proceder a la puesta en marcha del m dulo electr nico Pulsador Manual de Alarma Informaci n de seguridad e NUNCA conecte el pulsador directamente a 220V ac e I
7. e alarms or other hazard alarms in dry workplaces not subject to explosion hazards The call point is also available in other versions for other applications for example in housings with different colours and with a choice of different identification labels refer to table page 2 Operation i Observe Info Press screen centre inwards until the yellow tab indicator G is visible in the upper area and the red LED F is flashing Fig 4 Trigger alarm Push up the keyhole cover A to insert the key Fig 1 Reset Detector with glass screen Open housing and remove the broken glass Turn key C clockwise until the right L stop position Fig 5 Replace glass screen and turn key M anti clockwise until the left stop position to lift screen upwards Fig 6 Detector with plastic operating panel Turn key C clockwise until the right L stop position Fig 5 Align the plastic operating panel K and turn key M anti clockwise until the left stop position to lift screen upwards Fig 6 Test mode Turn key C clockwise L until the screen moves downwards and the activation F G is indicated Fig 4 To reset the detector after a test simply turn key M to the left stop position to lift screen upwards Installation Flush mounting The Manual Call Point is installed on a conventional standard housing 55 60mm Surface The Manual Call Point is installed on a back box for mounting surface mounting opt
8. i n Fig 3 Etiqueta Para indicar equipo fuera de uso J L mina de Gire la llave en sentido horario hasta el tope pl stico o cristal derecho L Fig 5 Inserte la l mina o cristal en su posici n H K en el hueco frontal deslice la l mina hacia arriba girando la Ilave en sentido contrahorario hasta su tope M Fig 6 S mbolo Terminales Los terminales 1 4 pueden extraerse para facilitar la instalaci n Fig 10 La pantalla del cable debe interconectarse en regleta separada La caja de superficie tiene un terminal apropiado para conectar la pantalla opcional Fig 7 Cubierta Para proteger de activaciones no intencionadas y Abatible para aumentar el grado de protecci n de IP 43 a IP Ref 704965 55 La cubierta abatible N se inserta en los opcional orificios laterales O de la carcasa y puede precintarse en caso necesario B Fig 2 9 Instalaci n t pica Fig 10 El pulsador convencional puede conectarse a la zona de incendios de un panel convencional o a la entra de de un transponder esserbus en paneles 8000 IQ8Control de detecci n de incendio Conecte los cables de zona a los terminals 1 4 Fig 10 El ultimo pulsador de la zona debe terminarse con la Resistencia de control de l nea habitualmente 10KQ en las zonas convencionales de equipos de ESSER Caracter sticas T cnicas Alimentaci n 8Vcca3oV cc Tensi n de funccionamiento 9Vcc Consumo alarma 9mA aprox A 9Vcc N mero Pulsadore
9. ion or with an universal installation frame for wall mounting option The call point securely on a suitable wall with a smooth surface e g with 2 screws length gt 40mm and dowels S6 Fig 7 8 Insert the key with the both tenons in the opening at the bottom of the housing Fig 2 to release the cover lock Lift up the bottom edge of the cover a little to release it and then remove it Opening Closing Turn key lock anti clockwise until the left M stop position Fig 6 Position the upper edge of the cover in the groove at the top of the base and then press the cover down until it locks into position Open the housing and remove the transparent plastic cover D E by prising it out Insert the appropriate identification label from the front Align the cover and snap it back into place Fig 3 To indicate that the detector is out of order J Symbolism Paper inlay Plastic operating Turn key lock clockwise until the right L stop panel or position Fig 5 Insert screen H K aligned in the glass screen front recess und move screen upwards by turning the key anti clockwise until the left M stop position Fig 6 The screw terminals 1 4 can be removed to simplify the installation Fig 10 The cable shield of the connection cable must be interconnected by using a single terminal block The back box option provides an integrated screw terminal for the shield connection Fig 7 Terminals Hinged c
10. nstale el pulsador dentro el rango de temperatura especificado e Solo t cnicos cualificados que est n familiarizados con los riesgos espec ficos y las normativas correspondientes deben llevar a cabo las operaciones de reparaci n y mantenimiento del Pulsador e El pulsador no debe ser alterado ni modificado General El pulsador electr nico Ref 804950 o el pulsador manual Ref 804970 con carcasa roja est identificado con un s mbolo de una casa ardiendo para activaci n manual de sistemas de alarma u otros sistemas en espacios secos no sujetos a riesgos de explosi n El pulsador tambi n est disponible en otras versiones para otras aplicaciones por ejemplo en carcasas de diferentes colores y con elecci n de diferentes colores o etiqueta de identificaci n ver tabla p gina 2 Funccionamiento Revise sta informaci n Activar Alarma Presione el cristal hacia adentro hasta que aparezca la leng eta amarilla G en la zona superior de la ventana y el LED Rojo F parpadee Fig 4 Suba la cubierta de llave A e inserte la llave Fig 1 Rearme Pulsador con Cristal Abra la caja y retire el cristal Gire la llave C en sentido horario hasta el tope derecho L Fig 5 Abra la cubierta y reemplace el cristal gire la llave en sentido contrahorario hasta el tope izquierdo M para subir la l mina Fig 6 Pulsador con l mina rearmable Gire la llave C en sentido horario hasta el tope derecho L Fig
11. over To protect the detector for unintended activation Part No 704965 and to increase the protection rating from IP 43 up Option to IP 55 The hinged cover N is fixed by the sideway dents O of the housing and may be plumbed B if required Fig 2 9 Typical wiring Fig 10 The MCP can be connected to a conventional detector zone of a fire alarm control panel or to the zone input of an esserbus transponder in a System 8000 or IQ8Control fire alarm control panel Connect the signal cable to terminals 1 4 Fig 10 The last call point in the zone must be fitted with a terminating resistor This should be a 10KO resistor for all Esser conventional detector zones Specification Power supply range 8VDCto30VDC Operation voltage 9VDC Alarm current approx 9 mA 9 V DC MCP per zone max 10 MCP acc to VdS Alarm indicator red LED and yellow tab Connection terminals max 2 5mm AWG 26 14 Application temperature 20 C to 70 C Storage temperature 30 C to 75 C Protection rating IP 43 in housing IP 55 with hinged cover Housing PC ASA plastic Colour red similar RAL 3020 Weight approx 110g Housing dimensions w x h x d Dimensions with back box Call point specification VdS approval 88 x 88 x 21 mm 88 x 88 x 57 mm EN 54 11 type A G 205131 CE Opci n Ref Options Part No Carcasa Azul similar RAL 5015 704951 Housing for MCP blue similar to RAL 5015 704951 Cristal de repuesto 10 Uds
12. s max 10 por zona VdS Indicaci n alarma LED rojo l mina amarilla Terminales 2 5 mm m x AWG 26 14 Temperatura trabajo 20 C a 70 C Temperatura almacenamiento 30 C a 75 C Grado de protecci n IP 43 en carcasa IP 55 con cubierta abatible Caja Pl stico PC ASA Color Rojo similar RAL 3020 Peso 110 g aprox Dimensiones a x h x f Diemnansiones c caja sup Especificaci n Certificado VdS 88 x 88 x 21 mm 88 x 88 x 57 mm EN 54 11 Typ A G 205131 Important Any damage caused by failure to observe the installation instructions voids the product guarantee Furthermore no liability can be accepted for any consequential damage arising from such failure These instructions must be studied carefully before commissioning the conventional Electronic module Manual Call Point MCP Safety information e NEVER connect the MCP directly to a 230V AC mains power supply e Only operate in the specified ambient temperature range e Only qualified technicians who are fully familiar with all the associated hazards and the applicable legislation and regulations may perform maintenance and repair work on the call point e The call point may not be changed or modified in any way General The conventional Electronic module Part No 804950 or Manual Call Point Part No 804970 in the red housing identified with a burning house symbol is designated for use as a call point for manually triggering fir
Download Pdf Manuals
Related Search
Related Contents
Automne-Hiver 2012 User Manual Philips BDP3000 User's Manual Craftsman 28035 Lawn Mower User Manual Pentax PF-CA35 BODITRAK GOLF .:.. CUSEZAR VOTRE SANTÉ ET VOUS - Publications du gouvernement du Canada Black Box FOQLS cable network tester Copyright © All rights reserved.
Failed to retrieve file