1. Figure 7 Pulley Alignment Dayton Dayton Operating Instructions and Parts Manual Dayton Belt Drive Upblast Axial Emergency Smoke Exhaust Ventilator Operation 1 Before starting up or operating your new Dayton ventilator check all fasteners for tightness In particular check set screws in propeller hub and sheaves if applicable While in the OFF position or before connecting the ventilator to power turn the fan propeller by hand to be sure it is not striking the orifice or any obstacle 2 Start the ventilator up and shut it off immediately to check rotation of the propeller with directional arrow placed on the unit Ventilator propeller should rotate clockwise when viewed from the top 3 When the ventilator is started observe the operation and check for any unusual noises 4 With the system in full operation and all duct work attached measure current input to the motor and compare with the nameplate rating to determine if the motor is operating under safe load conditions IMPORTANT Adjust tighten belt tension after the first 48 hours of operation 5 Keep inlets and approaches to ventilator clean and free from obstruction Maintenance AWARNING Disconnect and lockout power source before servicing Uneven cleaning of the A CAUTION propeller will produce an out of balance condition that will cause vibration in the ventilator 1 K
2. Form 555541 Printed in U S A 468878 O pee Rev 2 October 2006 Day ton 1006 268 VCPVP Dayton Operating Instructions and Parts Manual 2RB67 Dayton Belt Drive Upblast Axial Emergency Smoke Exhaust Ventilator Unpacking 1 Inspect for any damage that may have occurred during transit 2 Shipping damage claim must be filed with carrier 3 Check all bolts screws set screws etc for looseness that may have occurred during transit Retighten as required Rotate propeller by hand to be sure it turns freely Do not raise ventilator A CAUTION by its windband use lifting lugs provided General Safety Information When Installing or Servicing the Fan Do not depend on any A DANGER pitii as the sole means of disconnecting power when installing or servicing the fan Always disconnect lock and tag power source before installing or servicing Failure to disconnect power source can result in fire shock or serious injury Motor will restart without warning after thermal protector trips Do not touch operating motor it may be hot enough to cause injury Do not place any body A DANGER parts or objects in fan motor openings or drives while motor is connected to power source AWARNING Do not use this equipment in explosive atmospheres Extreme care must be A CAUTION taken when working around the damper lifter assemblies or serious bodily injury or death may result These f
3. B Shell Alvania 2 Texaco Multifak 2 Texaco Premium RB Unirex N2 Dayton Operating Instructions and Parts Manual 2RB67 For Repair Parts call 1 800 323 0620 24 hours a day 365 days a year Please provide the following information Model number Serial number if any Part description and number as shown in parts list Address parts correspondence to Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A Reference Part Number For Model Number Description 2RB67 Quantity 1 Windband Assembly 50B887 1 2 Damper Assembly 50B888 1 3 Magnetic Latch Assembly 50B893 1 4 Damper Lifter Spring Assembly 50B886 1 5 Base Assembly 50B890 1 6 Motor Cover 50B885 1 7 Propeller Assembly 50B889 1 8 Drive Frame Assembly 50B891 1 9 Belt Tube Assembly 50B892 1 Figure 8 Repair Parts Illustration Notes Dayton Operating Instructions and Parts Manual 2RB67 Dayton Belt Drive Upblast Axial Emergency Smoke Exhaust Ventilator Trouble Shooting Chart Symptom Possible Cause s Corrective Action Ventilator Inoperative 1 Blown fuse or breaker 1 Replace or repair 2 Defective motor 2 Replace or repair 3 Incorrectly wired 3 Shut power OFF and check wiring for proper connections 4 Broken belts 4 Replace Insufficient airflow 1 Speed too slow 1 Check for correct drives 2 Damper closed 2 Inspect repair damper 3 Belt slippage 3 Replace adj
4. Siga todos los c digos el ctricos y de seguridad locales de Estados Unidos y Canad as como tambi n el C digo Nacional El ctrico de Estados Unidos NEC la Ley de Seguridad y Salud Ocupacional OSHA y el Comunicado 96 de la Asociaci n Nacional de Protecci n contra Incendios NFPA de Estados Unidos Conectar a tierra el motor seg n el Art culo 250 del NEC conexi n a tierra Siga el C digo El ctrico Canadiense CEC en Canad 4 El motor y el ventilador deben estar conectados a tierra metal desnudo en un buen terreno el ctrico como un ca o de agua en la tierra o un sistema de cableado en tierra NOTA Consulte la Figura 3 para ver el diagrama de la instalaci n el ctrica MOTOR CAJA J L1 SUMINISTRO DE VOLTAJE 208 230 460 60 3 SUMINISTRO DE VOLTAJE 115 208 230 60 1 Figura 3 Diagrama de una Instalaci n El ctrica T pica z En los Estados A PRECAUCI N Unidos para reducir el riesgo de da os a las personas la OSHA exige el uso de guardas cuando el ventilador est instalado a 2 1 metros 7 pies del suelo o del rea de trabajo z En Canad para APRECAUCION reducir el riesgo de da os a las personas la OSHA exige el uso de guardas cuando el ventilador est instalado a menos de 2 5 metros 8 2 pies del suelo o nivel de pendiente 5 No tuerza el cable de alimentaci n ni permita que entre en contacto con objetos filosos aceites grasa su
5. and servicing is simplified with motor out Of application the airstream design A removable motor cover enables quick and easy access to the motor belt and drives from the roof deck Dayton Electric Mfg Co certifies that the models shown herein are licensed to bear the AMCA seal The ratings shown are based on tests and procedures performed in Us LISTED E53236 accordance with AMCA Publication MH45468 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program amca CERTIFIED RATINGS IntennaTionat 1n0 5 6 Dimensions and Specifications See Figure 1 Recommended Prop Shaft Roof Model Dia Dia Opening 2RB67 48 1 4 52 x 52 Figure 1 Dimensions Performance CFM Air Delivery Static Pressure Shown 000 125 250 375 500 SP SP SP SP SP 2RB67 48 2 433 2 20 18 4 25642 22583 18650 3 496 3 31 23 29373 26836 23563 19730 5 587 5 49 29 34761 32809 30166 27319 24091 Performance certified is for installation type A Free inlet Free outlet Power rating BHp does not include transmission losses Performance ratings do not include appurtenances accessories The sound ratings shown are loudness values in fan sones at 5 ft 1 5m in a hemispherical free field calculated per AMCA Standard 301 Values are for installation type A free inlet fan sone levels The AMCA Certified Ratings Sound Seal applies to sone ratings only
6. assembled installed and serviced by a qualified technician Have all electrical work performed by a qualified electrician 3 Follow all local and national electrical and safety codes in the United States and Canada for Emergency Smoke Exhaust Ventilators as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA in the United States Ground motor in accordance with NEC Article 250 grounding Follow the Canadian Electric Code CEC in Canada 4 Motor and fan must be securely grounded bare metal to a suitable electric ground such as a grounded water pipe or ground wire system NOTE Refer to Figure 3 for connection wiring diagram MOTOR SUPPLY VOLTAGE 115 208 230 60 1 J BOX L1 L2 MOTOR SUPPLY VOLTAGE 208 230 460 60 3 J BOX L1 L3 L2 Figure 3 Typical Wiring Diagram In United States to A CAUTION reduce the risk of injury to persons OSHA complying guards are required when fan is installed within 7 feet of floor or working level In Canada to reduce A CAUTION the risk of injury to persons CSA complying guards are required when fan is installed below 2 5 meters 8 2 feet above floor or grade level 5 Do not kink power cable or allow it to come in contact with sharp objects oil grease hot surfaces or chemicals Replace damaged cords immediately 6 Ma
7. incluye las p rdidas de transmisi n Los resultados de rendimiento no incluyen los accesorios Los resultados de ruido mostrados son valores de sonora en sonidos del ventilador a 1 5 m 5 pies en un campo hemisf rico libre calculado por el Est ndar 301 de la AMCA Los valores mostrados son para Instalaci n Tipo A Niveles de sonidos del ventilador de entrada libre El sello de ruido Certified Ratings Niveles certificados de AMCA se aplica s lo a niveles de sonidos Formulario 555541 Impreso en EE UU 04632 1006 268 VCPVP 468878 Rev 2 de octubre 2006 Dayton Manual de Instrucciones de Operaci n y Lista de Partes Dayton 2RB67 Extractor Axial de Humo de Emergencia de Techo de Tiro Arriba y Transmisi n por Correa Dayton Desempaque 1 Inspeccione cualquier da o que pueda haberse producido durante el traslado 2 El da o durante el env o debe ser reclamado al transporte 3 Verifique pernos tornillos y tornillos de presi n que puedan haberse aflojado durante el traslado Vuelva a ajustarlos seg n se requiere Gire la rueda a mano para asegurarse de que gira libremente No levante el A PRECAUCI N ventilador por sus paletas use una eslinga de carga o una plataforma Informaci n General sobre Seguridad al Realizar la Instalaci n o el Service del Ventilador No dependa de A PELIGRO ps cualquier interrumptor como el nico medio de desconexi n de la energ a cuando reali
8. techo plana o con una base de montaje fija de techo inclinada que proporcionen terceros 1 Haga un orificio en la superficie del techo Siga las instrucciones de instalaci n del fabricante de la base Selle con masilla y aisle la base para lograr una junta resistente al agua 2 Use las orejetas para izar para colocar el ventilador en la base de montaje fija 3 Asegure el ventilador a la base usando un m nimo de ocho sujetadores 4 Verifique que la rueda del ventilador gire libremente 5 Verifique que todos los sujetadores est n bien ajustados 6 Monte y conecte el interruptor de desconexi n segura en el bastidor motriz o fuera de la tapa de la base de montaje fija y conecte el motor seg n el diagrama de cableado del motor Conecte los interruptores de control a nivel del suelo Consulte la Figura 3 anterior para conocer el diagrama de cableado Montaje del Motor y la Polea NOTA Para las unidades que figuran en la U L el motor usado con este extractor debe ser designado como tal por Dayton 1 Afirme el motor a la placa usando el hardware incluido Los orificios se alinear n cuando la estructura del motor extremo del eje est al ras del borde de la placa del motor 2 Coloque las poleas sobre los ejes afirm ndolas con tornillos de presi n Verifique que las poleas est n bien alineadas Las poleas mal alineadas producen un desgaste Figura 5 Diagrama de la Unidad de Transmisi n e
9. 2331 en EE UU Llame al 1 800 323 0620 Servicio permanente 24 horas al d a al a o Por favor proporci nenos la siguiente informaci n N mero de modelo N mero de serie si lo tiene Descripci n de la parte y n mero que le corresponde en la lista de partes Env e correspondencia relacionada con pedidos de partes a Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A Numero de Numero de Parte para Modelos Referencia Descripci n 2RB67 Cantidad 1 Ensamble de la Banda para viento 50B887 1 2 Ensamble del Regulador de tiro 50B888 1 3 Conjunto de conexi n magn tica 50B893 1 4 Conjunto de resorte del elevador del regulador de tiro 50B886 1 5 Ensamble de la base 50B890 1 6 Tapa del Motor 50B885 1 7 Ensamble de la H lice 50B889 1 8 Ensamble de la Estructura de Transmisi n 50B891 1 9 Conjunto de tubo para correa 50B892 1 Figura 8 Ilustraci n de Partes de Reparaci n Notas 5 Sp Manual de Instrucciones de Operaci n y Lista de Partes Dayton 2RB67 Extractor Axial de Humo de Emergencia de Techo de Tiro Arriba y Transmisi n por Correa Dayton Cuadro de Soluci n de Problemas S ntoma Causa s Posible s Medida Correctiva El ventilador no funciona 1 Fusible o disyuntor quemado 1 Cambiar o reparar 2 Motor con fallas 2 Cambiar o reparar 3 Los cables est n mal colocados 3 Corte la fuente de alimentaci n y verifique la instalaci n e
10. ARRANTY DISCLAIMER Dayton has made a diligent effort to provide product information and illustrate the products in this literature accurately however such information and illustrations are for the sole purpose of identification and do not express or imply a warranty that the products are MERCHANTABLE or FIT FOR A PARTICULAR PURPOSE or that the products will necessarily conform to the illustrations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While Dayton attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product review the product applications and all applicable national and local codes and regulations and be sure that the product installation and use will comply with them Certain aspects of disclaimers are not applicable to consumer products e g a some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you b also some jurisdictions do not allow a limitation on
11. Operating Instructions amp Parts Manual Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury andlor property damage Retain instructions for future reference Dayton Belt Drive Upblast Axial Emergency Smoke Exhaust Ventilator Description Optional Accessories Dayton exhaust ventilators are designed for industrial and commercial buildings oe General or UL 705 such as warehouses manufacturing facilities foundries and laboratories The axial Description Model No s upblast fan is constructed of heavy gauge galvanized steel and is UL listed for l n o 6 Adj Roof Curb 3C216 Emergency Smoke Control Continuous operating temperature of 120 F It is Ae rated for 500 F for a minimum of 4 hours 1000 F for a minimum of 15 minutes ne Adj Curb 30439 and includes a UL 793 Snow Loading Rating UL 793 ensures that the dampers will 8 Fixed Roof Curb APAT 12 Fixed Roof Curb 4HX53 open in the event of a fire by requiring 10 Ibs of lifting force per square foot This fan features 165 F fusible link on the damper lifters a belt tube with heat shield Do notuseinany and high temperature bearings Lifting lugs on windband are provided for easy AWARNING chen exhaust lifting during installation Inspection
12. ans have extra heavy duty fusible link damper lifters under very high spring tension that must be pinned so they can not be accidentally tripped when servicing the fan The fusible link damper lifters are located under the butterfly damper blades Figure 2 Detail A shows where the two safety pins will be located when shipped from the factory When maintenance is being performed on the fan the pins MUST be moved from Detail A position to Detail B position Detail A shows where the two safety pins are placed when the fan is in service Safety Pin Storage Location To Prevent Closure While Servicing Fan Detail A Detail B Figure 2 Damper Lifter IMPORTANT ELECTRICAL If fan motor is NOT thermally protected remote overload protection must be installed having adequate rating as to voltage frequency horsepower and full load current per phase Where connected to a circuit protected by fuses use time delay fuses For supply connection use wires rated for at least 90 C 194 F INSTALLATION When connecting electrical power to this fan do not restrict motor movement Motor must have sufficient movement for possible future belt or wheel adjustment 454975 Listed Power Ventilator For Smoke Control Systems 76Y9 1 Read and follow all instructions and cautionary markings Make sure electrical power source conforms to requirements of equipment and local codes 2 Ventilators should be
13. bricaci n y se devuelva a una sucursal de Grainger con los costos de env o previamente pagos ser como nico remedio reparada o remplazada a criterio de Grainger Por demanda de garant a limitada ver DISPOSICI N INMEDIATA a continuaci n Esta garant a limitada le da al comprador derechos legales espec ficos que var an de una jurisdicci n a otra RESTRICCI N DE RESPONSABILIDAD DAYTON NO SE RESPONSABILIZAR POR DA OS RESULTANTES ACCIDENTALES ESPECIALES EJEMPLIFICANTES O PUNITIVOS LA RESPONSABILIDAD DE DAYTON EN NINGUN CASO EXCEDER EL PRECIO DE COMPRA PAGADO POR EL PRODUCTO QUE SUSCITE CUALQUIER RESPONSABILIDAD Denegaci n de Garant a Dayton se ha esforzado por suministrar informaci n sobre el producto e ilustrar con precisi n los productos de este manual sin embargo dichas informaci n e ilustraciones s lo son para identificaci n y no expresan ni implican una garant a de que los productos son comerciables o se adaptan a un prop sito en particular o que los productos necesariamente estar n de acuerdo con las ilustraciones o descripciones Con excepci n de lo que se detalla a continuaci n ninguna garant a ni afirmaci n de hecho expresa o impl cita aparte de lo que se incluye en la GARANT A LIMITADA est hecha o autorizada por Dayton APTITUD DEL PRODUCTO Muchas jurisdicciones tienen c digos y ordenanzas que regulan las ventas la construcci n la instalaci n y o el uso de productos para ciertos pr
14. eep inlets and approaches to ventilator clean and free from obstruction Depending on the usage and severity of the contaminated air a regularly scheduled inspection for cleaning the fan propeller ventilator and surrounding areas should be established 2 Check for unusual noises when fan is running 3 Periodically inspect and tighten set screws 4 Periodically check belts for wear and tightness NOTE When replacing belts use the same type as supplied with the unit For belt replacement loosen the tension device far enough to allow removal of the belt by hand Do not force belts on or AWARNING off This may cause cords to break leading to premature belt failure 5 Most ventilator bearings are pre lubricated and require no further lubrication check bearings 6 Follow motor manufacturer s instructions for motor lubrication 7 For disassembly of the motor or propeller refer to the parts illustration 8 For critical applications a spare motor and belts should be available Recommended Relubrication Frequency in Months Operating Bore in Inches Speed RPM 1 2 to 1 Up to 500 6 500 1000 6 1000 1500 5 NOTE If unusual environmental conditions exist extreme temperature moisture or contaminants more frequent lubrication is recommended Any good quality lithium base grease conforming to NLGI Grade 2 consistency such as those listed here may be used Mobil 532 Mobilux 2
15. how long an implied warranty lasts consequently the above limitation may not apply to you and c by law during the period of this Limited Warranty any implied warranties of implied merchantability or fitness for a particular purpose applicable to consumer products purchased by consumers may not be excluded or otherwise disclaimed PROMPT DISPOSITION Dayton will make a good faith effort for prompt correction or other adjustment with respect to any product which proves to be defective within limited warranty For any product believed to be defective within limited warranty first write or call dealer from whom the product was purchased Dealer will give additional directions If unable to resolve satisfactorily write to Dayton at address below giving dealer s name address date and number of dealer s invoice and describing the nature of the defect Title and risk of loss pass to buyer on delivery to common carrier If product was damaged in transit to you file claim with carrier Manufactured for Dayton Electric Mfg Co 5959 W Howard St Niles Illinois 60714 U S A Manufactured for Dayton Electric Mfg Co Niles Illinois 60714 U S A Dayton Manual de Instrucciones de Operaci n y Lista de Partes Dayton Por favor lea y guarde estas instrucciones L alas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqui descrito Prot jase usted mismo y a los dem s observando toda la
16. ici n del Detalle B El Detalle A muestra en donde se colocan los dos pasadores de seguridad cuando el ventilador est en servicio Para evitar el cierre mientras se realiza mantenimiento al ventilador Ubicaci n de almacenamiento del pasador de seguridad Figura 2 Elevador del Regulador de Tiro Detalle A Detalle B IMPORTANTE EL CTRICO Si el motor del ventilador NO se protege t rmicamente se debe instalar una protecci n remota contra sobrecarga que cuente con una clasificaci n adecuada en cuanto a voltaje frecuencia caballos de fuerza y corriente a plena carga por fase Cuando se conecte a un circuito protegido por fusibles use Ventilador el ctrico fusibles con tiempo de retardo Para la conexi n indicado de suministro use cables clasificados para al para menos 90 C 194 F sistema INSTALACI N Cuando conecte la energ a de control el ctrica a este ventilador no restrinja el de humo movimiento del motor El motor debe tener el 76Y9 movimiento suficiente para un posible ajuste futuro de la correa o rueda 454975 Lea y siga todas las instrucciones y las notas preventivas Asegurese de que la fuente de energ a el ctrica cumple con los requerimientos de equipos y c digos locales 2 El montaje la instalaci n y el service de los ventiladores deben ser realizados por t cnicos calificados Haga realizar todo el trabajo de electricidad por un electricista calificado 3
17. informaci n de seguridad El no cumplir con las instrucciones puede ocasionar da os tanto personales como a la propiedad Guarde estas instrucciones para referencia en el futuro Extractor Axial de Humo de Emergencia de Techo de Tiro Arriba y Transmisi n por Correa Dayton Descripci n Los extractores Dayton est n dise ados para edificios industriales y comerciales as como tambi n para almacenes f bricas fundiciones y laboratorios El extractor Accesorios Opcionales UL General 705 axial de techo de tiro hacia arriba est fabricado de acero galvanizado de calibre mesernsien Modelo N grueso y cuenta con certificaci n UL para el control del humo de emergencia Base de Montaje Ajustable Temperatura de funcionamiento continua de 48 9 C 120 F Est clasificado para de15 2cm 3C216 260 C 500 F durante un tiempo m nimo de 4 horas 537 8 C 1000 F durante un pod Ajustable Senda tiempo m nimo de 15 minutos e incluye una clasificaci n de carga de nieve UL 793 E de Monti Fija UL 793 garantiza que los reguladores de tiro se abrir n en caso de incendio de 20 3 cm AHX45 exigiendo 10 Ib de fuerza ascensional por pie cuadrado Este ventilador incluye una Base de Montaje Fija conexi n con fusible de 73 8 C 165 F en los elevadores del regulador de tiro un de 30 5 cm 4HX53 tubo para correa con pantalla t rmica y rodamientos de alta temperatura Las orejetas para izar de la abrazadera de izada se proporci
18. ke certain that the power source conforms to the requirements for the equipment Dayton Operating Instructions and Parts Manual Model 2RB67 7 For Emergency Smoke Exhaust Ventilator installations the electrical supply must be kept out of the airstream They may also require an isolated power supply so that if power is cut to the building in the event of a fire the fan will continue to operate 8 Never open access door to a duct with the ventilator running 9 Motor must be securely and adequately grounded This can be accomplished by wiring with a grounded metal clad race way system by using a separate ground wire connected to the bare metal of the motor frame or other suitable means Installation Installation AWARNING troubleshooting and parts replacement is to be performed only by a qualified personnel NOTE Refer to motor nameplate for wiring procedures Refer to switch manufacturer for installation and wiring procedures ROOF MOUNTING Lifting Lugs H UT 3 4 8 or 12 po Recommended Roof Opening Figure 4 Typical Roof Mounting Installation NOTE Mount unit on a flat roof surface or mount with a pitched roof curb supplied by others 1 Cut an appropriate sized hole in the roof surface Follow curb manufacturer s installation instructions Caulk and flash curb to ensure a water tight seal 2 Use lifting lugs to place ventilator on top of curb 3 Secure
19. l ctrica Correas rotas Cambiar Verificar la propulsi n Inspeccionar reparar Cambiar ajustar tensi n Verificar la instalaci n el ctrica del motor La velocidad es demasiado lenta Regulador de tiro cerrado Resbalamiento de la correa Flujo de aire insuficiente Rotaci n de la h lice incorrecta Ajuste los tornillos de presi n Volver a alinear Ajustar bien Cambiar la h lice H lice o roldanas flojas Roldanas mal alineadas Demasiado ruido o vibraci n La base del ventilador no est bien afirmada La h lice del ventilador est desequilibrada La RPM de la h lice es demasiado alta Bobinas del motor m s cortas Verificar propulsi n Cambiar motor El motor se sobrecarga o se recalienta Rotaci n de la h lice incorrecta Verificar la instalaci n el ctrica del motor Poco demasiado voltaje Resbalamiento de la correa Consultar al proveedor del servicio de energ a UU bh UN a ab una WD OBWNY HI R WYN HIB WYN a Tensar correa GARANT A LIMITADA DE UN A O DAYTON Los Extractores Axial de Humo de Emergencia de Techo de Tiro Arriba y Transmisi n por Correa Dayton los modelos incluidos en este manual tienen garant a de Dayton Electric Mfg Co Dayton por defectos de fabricaci n o materiales durante su uso normal durante un a o a partir de la fecha de compra Cualquier pieza que se considere con fallas en cuanto al material o la fa
20. nda el ventilador y ap guelo inmediatamente para verificar la rotaci n de la h lice con la flecha direccional colocada en la unidad La rueda del ventilador debe girar en el sentido de las agujas del reloj cuando se lo mira desde arriba Cuando el ventilador est encendido observe su operaci n y verifique si hay alg n ruido inusual Con el sistema funcionando a pleno y todos los conductos fijados mida la entrada de corriente al motor y comp rela con la medici n de la placa de identifiaci n para determinar si el motor est operando en condiciones de carga segura IMPORTANTE Ajuste ponga tirante la tensi n de la correa despu s de las primeras 48 horas de operaci n 5 Mantenga las entradas y las reas cercanas al ventilador limpias y sin obstrucciones NOTA Cuando cambie las correas use el mismo tipo que viene con la unidad Mantenimiento Desconente y corte A ADVERTENCIA fuente de i alimentaci n antes de realizar el Para cambiar la correa afloje el service dispositivo de tensi n lo suficiente ra La limpieza para poder quitar la correa a mano APRECAUCION desigual de la AADVERTENCIA M2 fuerce las correas Si lo hace las correas se romper n provocando fallas prematuras rueda provocar un desequilibrio que producir vibraci n en el ventilador 1 Mantenga las entradas y las reas cercanas al ventilador limpias y sin obstrucciones Seg n el us
21. o y la gravedad del aire contaminado debe establecerse un cronograma regular de inspecciones para limpiar la h lice del ventilador el ventilador y las reas circundantes 5 La mayor a de los rodamientos de los ventiladores viene previamente lubricado y no requiere lubricaci n extra verifique los rodamientos 6 Siga las instrucciones del fabricante del motor en cuanto a su lubricaci n 7 Para el desmontaje del motor o la h lice consulte la ilustraci n de piezas 2 Verifique la presencia de ruidos inusuales cuando el ventilador est funcionando 8 Para aplicaciones cr ticas debe haber un motor y correas de repuesto 3 Inspeccione y ajuste peri dicamente los tornillos de presi n 4 Verifique peri dicamente el desgaste y la tensi n de las correas Frecuencia Recomendada de Lubricaci n en Meses WET El Calibre en Pulgadas Operativa RPM hath Hasta 500 6 500 1000 6 1000 1500 5 NOTA En caso de condiciones ambientales inusuales temperatura humedad o contaminaci n extremas se recomienda mayor frecuencia de lubricaci n Puede usarse una grasa a base de litio de alta calidad seg n la consistencia Grado 2 del NLGI como las que aqu se enumeran Mobil 532 Mobilux 2 B Shell Alvania 2 Texaco Multifak 2 Texaco Premium RB Unirex N2 4 Sp Manual de Instrucciones de Operaci n y Lista de Partes Dayton 2RB67 Para Obtener Partes de Reparaci n en M xico Llame al 001 800 527
22. onan para un levantamiento A ADVERTENCIA Vo usar en ninguna f cil durante la instalaci n La inspecci n y el mantenimiento se simplifican con el aplicacion de dise o de motor fuera del flujo de aire Una cubierta desmontable del motor extracci n de cocina permite un acceso r pido y f cil al motor la correa y los accionamientos desde la plataforma del tejado Dayton Electric Mfg Co certifica que los modelos que aqu aparecen tienen licencia para llevar el sello de la AMCA Las mediciones expuestas est n basadas en pruebas y procedimientos realizados seg n las Publicaciones 211 y 311 de la AMCA y cumplen con los requerimientos del Programa de Resultados Certificados de la AMCA 182 5 cm Aus LISTED E53236 MH45468 Dimensiones y Especificaciones Ver Figura 1 Abertura del Techo Recomendada Di m del Eje Diam de 61 9cm PRA ans cm la H lice Modelo 2RB67 121 9 cm 3 2 cm 132 1 x 132 1 cm Figura 1 Dimensiones Rendimiento Suministro de Aire CFM Presi n Est tica Di m de RPM del Sonidos 0 000 0 125 0 250 0 375 0 500 Modelo la H lice HP WO ET te g 0 125 SP SP SP SP SP SP 2RB67 121 9 cm 2 433 2 2 18 4 25642 22583 18650 3 496 3 31 23 29373 26836 23563 19730 5 587 5 49 29 34761 32809 30166 27319 24091 El rendimiento mostrado es para la instalaci n en l nea tipo A Entrada libre Salida libre La medici n de energ a BHP no
23. op sitos que pueden variar con respecto a los de las reas vecinas Aunque Dayton procura asegurarse que sus productos cumplan con dichos c digos no puede garantizar el cumplimiento ni puede responsabilizarse por c mo se usa o instala el producto Antes de comprar o usar un producto revise las aplicaciones del producto y todos los c digos y ordenanzas locales y nacionales que se aplican y aseg rese de que el producto su instalaci n y su uso cumplan con los mismos Ciertos aspectos de la denegaci n no se aplican a productos del consumidor por ej a algunas jurisdicciones no permiten la exclusi n o la limitaci n de da os accidentales o resultantes por lo que la limitaci n o exclusi n mencionadas anteriormente pueden no aplicarse a usted b adem s algunas jurisdicciones no permiten una limitaci n sobre la duraci n de una garant a impl cita en consecuencia la limitaci n mencionada anteriormente puede no aplicarse a usted y c por ley durante el per odo de esta Garant a Limitada cualquier garant a impl cita de comerciabilidad o aptitud para un prop sito en particular que se aplique a productos del consumidor adquiridos por consumidores no puede ser exclu da ni rechazada DISPOSICI N INMEDIATA Dayton har un esfuerzo de buena fe por efectuar una inmediata correcci n u otro ajuste con respecto a cualquier producto que demuestretener fallas dentro de la garant a limitada En caso de existir un producto con fallas dent
24. perficies calientes o productos qu micos Reemplace inmediatamente los cables da ados 6 Aseg rese de que la fuente de alimentaci n cumple con los requerimientos del equipo 2 Sp Manual de Instrucciones de Operaci n y Lista de Partes Dayton 2RB67 Modelo 2RB67 7 Para instalaciones de extractores de humo de emergencia el suministro el ctrico se debe mantener fuera del flujo de aire Tambi n requieren que se a sle el suministro el ctrico de modo que si se corta la energ a al edificio en caso de incendio siga funcionando el ventilador 8 Nunca abra puertas de acceso a un conducto con el ventilador en funcionamiento 9 El motor debe tener una segura y adecuada conexi n a tierra Esto puede hacerse mediante un sistema de surco cubierto de metal conectado a tierra usando un cable separado conectado al metal desnudo de la estructura del motor u otro m todo apropiado Instalaci n La instalaci n la A ADVERTENCIA soluci n de problemas y el cambio de partes ser realizado s lo por personal calificado NOTA Consulte la placa de identificaci n del motor para ver la instalaci n el ctrica Consulte al fabricante de interruptores para la instalaci n el ctrica MONTAJE EN EL TECHO NOTA Monte la unidad sobre una Orejas H a Abertura del Techo z Recomendada Figura 4 T pica Instalaci n de Montaje en un Techo superficie de
25. ro de la garant a limitada escriba o llame al distribuidor a quien le compr el producto ste le indicar qu hacer Si el problema no se resuelve de manera satisfactoria escriba a Dayton a la direcci n que figura a continuaci n indicando nombre del distribuidor direcci n fecha y n mero de la factura del distribuidor y describa la naturaleza de la falla T tulo y riesgo de p rdida pasan al comprador en la entrega a la compa a de transporte Si el producto se da durante el transporte presente el reclamo al transporte Fabricado por Dayton Electric Mfg Co 5959 W Howard St Niles Illinois 60714 U S A Fabricado por Dayton Electric Mfg Co Niles Illinois 60714 U S A Dayton
26. ust tension 4 Incorrect propeller rotation 4 Check motor wiring Excessive noise or vibration 1 Loose propeller or sheaves 1 Tighten set screws 2 Mis aligned sheaves 2 Re align 3 Ventilator base not securely anchored 3 Secure properly 4 Fan propeller out of balance 4 Replace propeller Motor overloads or overheats 1 Propeller RPM too high 1 Check drives 2 Shorted motor winding 2 Replace motor 3 Incorrect propeller rotation 3 Check motor wiring 4 Over Under line voltage 4 Contact Power Co 5 Belt slippage 5 Tighten belt DAYTON ONE YEAR LIMITED WARRANTY Dayton Belt Drive Upblast Axial Exhaust Ventilators Models covered in this manual are warranted by Dayton Electric Mfg Co Dayton to the original user against defects in workmanship or materials under normal use for one year after date of purchase Any part which is determined to be defective in material or workmanship and returned to a Grainger branch shipping costs prepaid will be as the exclusive remedy repaired or replaced at Grainger s option For limited warranty claim procedures see PROMPT DISPOSITION below This limited warranty gives purchasers specific legal rights which vary from jurisdiction to jurisdiction LIMITATION OF LIABILITY DAYTON SHALL NOT BE LIABLE FOR CONSEQUENTIAL INCIDENTAL SPECIAL EXEMPLARY OR PUNITIVE DAMAGES DAYTON S LIABILITY IN ALL CIRCUMSTANCES SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT THAT GIVES RISE TO ANY LIABILITY W
27. ventilator to roof curb using a minimum of eight fasteners 4 Check ventilator propeller for free rotation 5 Check all fasteners for tightness 6 Mount and wire safety disconnect switch either on the drive frame or outside on the curb cap and wire motor per wiring diagram on motor Wire control switches at ground level Refer back to Figure 3 for connection wiring diagram Motor and Pulley Mounting NOTE For U L listed units the motor used with this fan must be designated as such by Dayton 1 Secure motor to plate using hardware provided Holes will align when the motor frame shaft end is flush with the edge of the motor plate 2 Mount pulleys on shafts securing to shaft with set screw Check pulleys for proper alignment Misaligned pulleys lead to excessive belt wear vibration noise and blower loss Figure 5 Drive Package Diagram 3 Install the belt and adjust the tension to allow for 1 64 of deflection per inch of span when moderate thumb pressure is applied to the belt Too much tension will cause excess bearing wear and noise Too little tension will cause slippage at startup and uneven wear Deflection _Belt Span in 64 in lt _ _ Belt Span Figure 6 Belt Tension 4 Adjust RPM to desired level using a variable pitch pulley After adjustment motor amperage should be checked to avoid overloading of the motor CORRECT WRONG
28. xcesivo de la correa vibraci n ruido y p rdida del soplador Instale la correa y ajuste la tensi n dejando 0 4 mm 1 64 de pulg de desviaci n por pulgada de distancia cuando aplique la presi n del dedo pulgar a la correa Demasiada tensi n provocar excesivo desgaste de los rodamientos y ruido Poca tensi n provocar resbalamiento en el arranque y desgaste desigual Ancho de la correa pulgadas Desviaci n pulgadas 64 pulgadas lt Ancho de la correa Figura 6 Tensi n de la Correa 4 Ajuste el nivel de RPM deseado usando una polea de inclinaci n variable Despu s del ajuste debe verificar el amperaje del motor para evitar sobrecargas en el motor CORRECTO INCORRECTO Figura 7 Tensi n de la Correa 3 Sp Dayton Manual de Instrucciones de Operaci n y Lista de Partes Dayton Extractor Axial de Humo de Emergencia de Techo de Tiro Arriba y Transmisi n por Correa Dayton Operaci n 1 Antes de comenzar a usar su nuevo ventilador Dayton verifique que todos los sujetadores est n ajustados En particular ajuste los tornillos en el centro de la h lice y las roldanas si se aplica Mientras est apagado o antes de conectar el ventilador a la fuente de alimentaci n gire la rueda del ventilador a mano para asegurarse de que no golpea el orificio ni otro obst culo Encie
29. za la instalaci n o el service del ventilador Siempre desconecte y desactive la fuente de energ a antes de la instalaci n o el service La no desconexi n de la energ a puede provocar incendios shock o da o grave El motor se reiniciar sin advertencias despu s de que se active el protector t rmico No toque el motor ya que puede estar muy caliente Tray No acerque partes del cuerpo u objetos al ventilador a las aberturas del motor o a los propulsores mientras el motor est conectado a la fuente de energ a No use este equipo A ADVERTENCIA en lugares explosivos Z Se debe tener sumo di PRECAUCI N cuidado cuando se trabaje cerca de los conjuntos elevadores del regulador de tiro ya que se pueden producir lesiones corporales graves o la muerte Estos ventiladores tienen elevadores del regulador de tiro de la conexi n con fusible para servicio extra pesado bajo una tensi n el stica muy alta que se debe fijar con pasadores de modo que no se desenganche accidentalmente cuando se realice mantenimiento al ventilador Los elevadores del regulador de tiro de la conexi n con fusible se encuentran debajo de las paletas de la compuerta de mariposa para regulaci n de tiro El Detalle A muestra en donde estar n los dos pasadores de seguridad cuando se env en de f brica Cuando se realice mantenimiento al ventilador los pasadores se DEBEN sacar de la posici n del Detalle A y colocar en la pos