Home
D-2380-EPS MCT-234, MCT-234 NB User Guide
Contents
1. All products accessories or attachments of others used in conjunction with the Product including batteries shall be covered solely by their own warranty if any The Manufacturer shall not be liable for any damage or loss whatsoever whether directly indirectly incidentally consequentially or otherwise caused by the malfunction of the Product due to products accessories or attachments of others including batteries used in conjunction with the Products This Warranty is exclusive to the original Purchaser and is not assignable This Warranty is in addition to and does not affect your legal rights Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply Warning The user must follow the Manufacturer s installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his her safety and the protection of his her property 1 08 1 INTRODUCCION El MCT 234 y el MCT 234 NB Banda estrecha son transmisores en miniatura CodeSecure M de 4 botones 4 funciones dise ados para utilizarse con sistemas de control remoto y de alarma de alta seguridad avanzados tales como el modelo UL de PowerMax de Visonic Ltd Para instalaciones UL utilice central enumerada como UL solo modelo PowerMax La transmisi n se inicia presionando cualquiera de los 4 botones Ante la presi n de un b
2. RESPONSABLE ANTE NADIE POR CUALESQUIERA DA OS Y PERJUICIOS INDIRECTOS O INCIDENTALES POR EL INCUMPLIMIENTO DE ESTA GARANT A O CUALESQUIERA OTRAS GARANT AS COMO SE MENCIONA ANTERIORMENTE EL FABRICANTE NO SER RESPONSABLE EN NING N CASO POR CUALESQUIERA DA OS ESPECIALES INDIRECTOS INCIDENTALES CONSECUENCIALES O PUNITIVOS O POR P RDIDAS DA OS O GASTOS INCLUYENDO P RDIDA DE USO BENEFICIOS INGRESOS O CR DITO MERCANTIL DIRECTA O INDIRECTAMENTE COMO RESULTADO DEL USO O INCAPACIDAD DE USO DEL PRODUCTO O POR LA P RDIDA O DESTRUCCI N DE OTRA PROPIEDAD O A RA Z DE CUALQUIER MOTIVO INCLUSO SI SE AVIS AL FABRICANTE DE LA POSIBILIDAD DE TALES DA OS EL FABRICANTE NO SER RESPONSABLE DE NINGUNA MUERTE LESI N PERSONAL Y O DA O CORPORAL Y O DA OS A LA PROPIEDAD U OTRAS P RDIDAS YA FUESEN DIRECTAS INDIRECTAS INCIDENTGALES CONSECUENCIALES O DE OTRO TIPO QUE SE BASEN EN UNA RECLAMACI N DE QUE EL PRODUCTO NO FUNCION El modelo 315 MHz de este dispositivo cumple con la Parte 15 de las normas FCC El funcionamiento est sujeto a las siguientes dos condiciones 1 Este dispositivo no puede provocar interferencia da ina y 2 este dispositivo debe aceptar cualquier interferencia que pueda ser recibida incluyendo interferencia que pueda provocar un funcionamiento indeseado El usuario es advertido que los cambios o modificaciones en la unidad no aprobados expresamente por Visonic Ltd podr a anular la autoridad FCC del u
3. Comprador declara ter concorda com as referidas condi es de venda e a garantia e reconhece ter sido informado das mesmas Algumas jurisdi es n o permitem a exclus o ou limita o de danos acidentais ou consequentes portanto essas limita es podem n o se aplicar em determinadas circunst ncias Em caso algum o Fabricante ser respons vel por danos decorrentes de corrup o e ou avaria de qualquer equipamentos de telecomunica es ou electr nico ou de qualquer programa A obriga o do Fabricante nos termos desta garantia est limitada exclusivamente repara o e ou substitui o segundo os crit rios do Fabricante de qualquer Produto ou parte do mesmo que esteja defeituoso Qualquer repara o e ou substitui o n o deve exceder o per odo da Garantia original O Fabricante n o ser respons vel por nenhumas despesas de desmontagem e ou reinstala o Para usufruir desta Garantia o Produto dever ser devolvido ao Fabricante com o porte de retorno pr pago e devidamente segurado Todas as despesas de transporte e de seguro s o da responsabilidade do Comprador e n o est o inclu das nesta arantia Esta garantia n o ser modificada alterada ou prorrogada nem o Fabricante autoriza qualquer pessoa a agir em seu nome com respeito modifica o altera o ou prorroga o desta garantia Esta garantia aplica se apenas ao Produto Todos os produtos acess rios ou perif ricos de terceiros usados em conjunto com o Produt
4. a low battery signal to the receiver Operating Temperature 0 to 49 C 32 to 120 F Dimensions MCT 234 53 5 x 31 5 x 12 5 mm 2 1 8 x 1 1 4 x 1 2 in MCT 234 NB 59 7 x 34 2 x 12 5 mm 2 3 8 x 1 3 8 x 1 in Weight including battery 21 g 3 4 oz Color Black Compliance with Standards FCC Part 15 EN 50131 1 EN 50131 3 EN 50131 6 Type C Grade 2 Class Il MCT 234 Certified by Applica T amp C MCT 234 NB was not evaluated for EN 3 TESTING AND MAINTENANCE 3 1 Testing a New Unit Since the MCT 234 is supplied with the battery already installed the unit is practically ready to be tested D 2380 EPS MCT 234 MCT 234 NB User Guide IMPORTANT Before testing teach the target receiver the ID code of the MCT 234 as instructed in the receiver s programming manual A Stand 3 m 10 ft away from a target receiver or wireless control panel and press the MCT 234 button marked with a closed padlock icon Verify that the transmit LED lights B Make sure that the receiver or control panel responds as programmed and as stated in the receiver s instruction manual C Operate the transmitter from various locations within the area covered by the receiver to determine dead locations where transmission is blocked by walls and large objects or affected by structural materials Note If dead marginal zones are a problem relocating the receiver may improve the performance 3 2 Replacing the Battery The battery should
5. de transmisi n luce B Aseg rese que el receptor o central responde como se program y como se estableci en el manual de instrucciones del receptor C Haga funcionar el transmisor desde varias posiciones dentro del rea cubierta por el receptor para determinar los sitios muertos donde la transmisi n es bloqueada por paredes y grandes objetos o afectados por materiales estructurales Nota Si las zonas muertas marginales son un probema reubicando el receptor puede mejorar el comportamiento 3 2 Sustituci n de la bater a La bater a deber a ser sustituida una vez al a o MCT 234 3 a os MCT 234 NB o al observar que el LED parpadea cuando transmite A Utilice un destornillador peque o Phillips para abrir el peque o tornillo de la parte trasera de la unidad Tenga cuidado en no perder el tornillo B Ponga la unidad hacia abajo y extraiga la bater a de su alojamiento vea Figura 2 Nota Aseg rese el elemento el stico que hay dentro de la tapa permanece en su lugar Pongalo en su lugar si se desprende C Inserte la bater a nueva y observe la polaridad D Pruebe la unidad presionando moment neamente uno de los botones de transmisi n El LED indicador deber a lucir E Ponga la tapa encima y una ambas partes con el tornillo 3 3 Limpieza El transmisor puede ensuciarse si se toc con los dedos grasientos L mpielo s lo con una prenda suave o una esponja humedecida ligeramente con una mezcla de agua
6. fecha de env o del Fabricante La presente garant a es absolutamente condicional a que el Producto se haya instalado mantenido y operado correctamente en condiciones de uso normal de acuerdo con las instrucciones de instalaci n y funcionamiento recomendadas por el Fabricante Esta garant a no cubre los productos que se hayan averiado por cualquier otro motivo seg n el criterio del Fabricante como instalaci n inadecuada no seguir las instrucciones de instalaci n y funcionamiento recomendadas negligencia da os voluntarios uso indebido o vandalismo da os accidentales modificaciones o manipulaciones o reparaciones realizadas por alguien que no sea el Fabricante El Fabricante no manifiesta que este Producto no se pueda allanar y o circunvenir ni que el Producto prevendr cualquier muerte y o lesi n personal y o da os a la propiedad como resultado de hurto robo incendio u otro ni que el Producto proporcionar en todo momento aviso o protecci n adecuados El Producto si se instala y mantiene de manera correcta s lo reduce el riesgo de dichos eventos sin aviso y no constituye una garant a o un seguro contra la ocurrencia de dichos eventos ESTA GARANT A SE DA EXCLUSIVA Y EXPL CITAMENTE EN LUGAR DEL RESTO DE LAS GARANT AS OBLIGACIONES O RESPONSABILIDADES YA FUESEN ESCRITAS VERBALES EXPL CITAS O IMPL CITAS E INCLUYENDO CUALQUIER GARANT A DE COMERCIABILIDAD O APTITUD PARA UN FIN PARTICULAR O DE OTRO TIPO EL FABRICANTE NO SER
7. o ou modifica es no equipamento que n o estejam expressamente aprovadas pela Visonic Ltd podem anular a autoriza o legal para a utiliza o do equipamento 4 3 Atribui o de Frequ ncias para Dispositivos Via R dio nos Pa ses Europeus UE e 433 92 MHz n o existem restri es em nenhum estado membro da UE 315 MHz n o permitida em nenhum estado membro da UE 868 95 MHz banda larga permitida em todos os estados membros da UE 869 2625 MHz banda estreita n o permitida em nenhum estado membro da UE E W E E E Declarac o de Reciclagem de Produtos E Para informa es acerca da reciclagem deste produto deve contactar a empresa onde o adquiriu Caso esteja a desfazer se deste produto e n o o volte a requerer ap s repara o deve ter a certeza de que a retoma conforme as indica es do fornecedor Este produto n o para deitar fora como o lixo di rio Directiva Europea 2002 96 EC Lixo de Equipamentos El ctricos e Electr nicos Entretanto no caso do Fabricante ser considerado respons vel quer directa ou indirectamente por quaisquer perdas ou danos resultantes desta garantia limitada A RESPONSABILIDADE M XIMO DO FABRICANTE SE EXISTIR N O DEVER EM CASO ALGUM EXCEDER O PRE O DO PRODUTO que passa a ser considerado como indemniza o e n o como multa sendo que este valor constituir a total e exclusiva repara o face ao Fabricante Ao aceitar a entrega do Produto o
8. p rdida del tipo que sea ya fuese directa indirecta incidental o consecuencialmente o de otra manera causadas por el mal funcionamiento del Producto debido a productos accesorios o acoplamientos de terceras partes incluidas bater as utilizados conjuntamente al Producto Esta garant a es exclusiva para el Comprador original y no es transferible Esta garant a complementa a y no afecta sus derechos legales Cualquier disposici n de esta garant a contraria al derecho del estado autonom a o pa s en que se suministre el Producto no ser aplicable Advertencia El usuario deber seguir las instrucciones de instalaci n y funcionamiento del Fabricante incluyendo probar el Producto y todo el sistema del mismo una vez a la semana como m nimo y tomar todas las precauciones necesarias para su seguridad personal y la protecci n de su propiedad 1 08 1 INTRODU O O MCT 234 e o MCT 234 NB banda estreita s o transmissores miniatura CodeSecure de 4 bot es 4 fun es desenhados para utilizar se com sistemas de controlo remoto e de alarme de alta seguran a tais como o modelo UL da PowerMax da Visonic Ltd Para instala es UL utilize centrais enumeradas como UL s o modelo PowerMax A transmiss o inicia se ao pressionar um dos 4 bot es Quando se pressiona um bot o em concreto o transmissor transmite uma sequ ncia digital CodeSecure identific vel pelos receptores compat veis com CodeSecure e um c digo d
9. y detergente suave y s quelo con un trapo immediatamente El uso de abrasivos de cualquier tipo est rigurosamente prohibido Tampoco utilice disolventes como queroseno acetona o diluyente D 2380 EPS MCT 234 MCT 234 NB User Guide 4 COMENTARIOS DIVERSOS 4 1 Limitaciones del producto Los sistemas inal mbricos de Visonic Ltd Son muy fiables y se prueban con los m s altos estandares Sin embargo debido a su baja potencia de transmisi n y cobertura limitada solicitado por FCC y otras autoridades reguladoras hay algunas limitaciones a ser consideradas A Los receptores pueden ser bloqueados por se ales de radio en la misma o cerca de sus frecuencias de funcionamiento sin considerar el c digo seleccionado B Un receptor s lo puede responder a una se al transmitida a la vez C El equipo inal mbrico deber a ser probado regularmente para determinar si hay fuentes de interferencia y protegerlo contra fallos 4 2 Cumplimiento de las normas Este dispositivo cumple con los requerimientos esenciales y las provisiones de la Directiva del 1999 5 EC Parlamento europeo y del Consejo del 9 de Marzo de 1999 sobre equipos terminales de radio y telecomunicaciones GARANT A Visonic Limited el Fabricante garantiza este producto solamente el Producto al comprador original el Comprador contra mano de obra y materiales defectuosos bajo uso normal del Producto por un periodo de doce 12 meses a partir de la
10. AA RA OA TTI D 23490 EP 3 MCT 234 MCT 234 NB al Visonic Wireless CodeSecure Keyfob Transmitter User Guide Pulsador inalambrico CodeSecure Guia del Usuario GB US AWAY GB US LED GB US Pressing AWAY and SP TOTAL SP LENTE HOME together for 2 seconds PT TOTAL PT LED initiate panic alarm 9 GB US DISARM SP Pulsar TOTAL y PARCIAL cal UONE SP DESARMAR juntos durante 2 seg inicia una PT PARCIAL PT DESARMAR alarma de PANICO GB US AUX PT Pressionar TOTAL e SP AUX PARCIAL juntos durante 2 Portuguese Comando Via Radio CodeSecure Manual de Utilizador PT AUX ue provoca um alarme Fig 1 MCT 234 1 INTRODUCTION The MCT 234 and MCT 234 NB Narrow Band are miniature CodeSecure 4 button 4 function transmitters designed for use with advanced high security alarm and remote control systems such as the Visonic Ltd UL listed model PowerMax For UL installations use UL listed control panel model PowerMax only Transmission is initiated by pressing any one of the four recessed pushbuttons Upon pressing a specific button the transmitter transmits a CodeSecure digital sequence identifiable by compatible CodeSecure receivers and a 4 bit function code associated with the button that was pressed The next time a button is pressed the transmitter will transmit a digital sequence that differs from the one used in the previous transmission and the respective function code As a re
11. EL MUELLE PT NOTA COLOQUE A PILHA COM O POLO NEGATIVO FAZER PRESSAO CONTRA A MOLA al Visonic INTERNET www visonic com VISONIC LTD 2014 MCT 234 4 D 2380 EPS REV 2 9 14 GB US SCREW HOLE SP AGUJERO TORNILLO 4 COMENTARIOS 4 1 Limitagoes do producto Os sistemas via r dio da Visonic Ltd s o muito fi veis e s o testados com os mais altos requisitos No entanto devido a sua baixa pot ncia de transmiss o e ao alcance limitado requerido por FCC e outras autoridades reguladoras h v rias considera es a ter em conta A Os receptores podem ser bloqueados por sinais de r dio com frequ ncias muito pr ximas das do equipamento B Um receptor s pode receber um sinal de cada vez C Os equipamentos via r dio devem testar se regularmente para determinar a exist ncia de fontes de interfer ncias e para proteg los contra falhas 4 2 Cumprimento de Normas O equipamento cumpre com os requisitos essenciais e provis es da Directiva 1999 5 EC do Parlamento Europeu e do Conselho de 9 de Mar o de 1999 de equipamento de r dio e telecomunica es O modelo de 315 MHz deste equipamento cumpre com o Par 15 das leis FCC As opera es est o sujeitas as seguintes condi es 1 este equipamento n o deve causar interfer ncias prejudiciais e 2 deve aceitar qualquer interfer ncia que possa ser recebida ou que cause opera es n o desejadas O utilizador fica avisado de que qualquer altera
12. N ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT which shall be fixed as liquidated damages and not as a penalty and shall be the complete and exclusive remedy against the Manufacturer When accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply under certain circumstances The Manufacturer shall be under no liability whatsoever arising out of the corruption and or malfunctioning of any telecommunication or electronic equipment or any programs The Manufacturers obligations under this Warranty are limited solely to repair and or replace at the Manufacturer s discretion any Product or part thereof that may prove defective Any repair and or replacement shall not extend the original Warranty period The Manufacturer shall not be responsible for dismantling and or reinstallation costs To exercise this Warranty the Product must be returned to the Manufacturer freight pre paid and insured All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty This warranty shall not be modified varied or extended and the Manufacturer does not authorize any person to act on its behalf in the modification variation or extension of this warranty This warranty shall apply to the Product only
13. NDO QUALQUER GARANTIA DE COMERCIALIZA O ADEQUA O A UMA FINALIDADE ESPEC FICA OU OUTRAS EM CASO ALGUM O FABRICANTE SER RESPONS VEL PERANTE ALGU M POR QUAISQUER DANOS CONSEQUENTES OU ACIDENTAIS RESULTANTES DA VIOLA O DESTA GARANTIA OU DE QUALQUER OUTRA GARANTIA COMO SUPRA REFERIDO EM CASO ALGUM O FABRICANTE SER RESPONS VEL POR QUAISQUER DANOS ESPECIAIS INDIRECTOS ACIDENTAIS CONSEQUENTES OU PUNITIVOS OU POR PERDA DE UTILIZA O RENDIMENTOS OU BOA VONTADE DIRECTA OU INDIRECTAMENTE RESULTANTES DA UTILIZA O OU INCAPACIDADE DE UTILIZA O DO PRODUTO POR PARTE DO COMPRADOR OU PELA PERDA OU DESTRUI O DE OUTRA PROPRIEDADE OU POR QUALQUER OUTRA RAZ O MESMO QUE O FABRICANTE TENHA SIDO ACONSELHADO DA POSSIBILIDADE DESSES MESMOS DANOS O FABRICANTE NAO SER RESPONS VEL POR QUALQUER MORTE FERIMENTOS PESSOAIS EOU F SICOS E OU DANOS MATERIAIS OU OUTRO TIPO DE PREJU ZOS DIRECTOS INDIRECTOS ACIDENTAIS CONSEQUENTES OU OUTROS COM BASE EM AFIRMA ES DE QUE O PRODUTO N O FUNCIONOU MCT 234 MCT 234 GB US BATTERY SP BATERIA PT BATERIA GB US LED INDICATOR SP INDICADOR LED PT LED INDICADOR PT FURA O DO GB US TRANSMIT SWITCH PARAFUSO SP SWITCH DE TRANSMIS N AN A PT SWITCH DE TRANSMISS O o NOR A f GB US NOTE INSERT BATTERY WITH NEGATIVE ON SE CUBIERTA EDGE PRESSED AGAINST THE CIRCULAR SPRING O PT TECLADO SP NOTA INSERTE LA PILA CON EL POLO NEGATIVO PRESIONANDO CONTRA
14. TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER AS AFORESAID THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS DAMAGE OR EXPENSE INCLUDING LOSS OF USE PROFITS REVENUE OR GOODWILL DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL ANDVOR BODILY INJURY ANDOR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION W E E E Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier This product is not to be thrown away with everyday waste European Directive 2002 96 EC Waste Electrical Equipment E and Electronic However if the Manufacturer is held liable whether directly or indirectly for any loss or damage arising under this limited warranty THE MANUFACTURER S MAXIMUM LIABILITY IF ANY SHALL NOT I
15. UL utilize baterias fabricadas por GP MCT 234 NB Bateria de 3V CR 2032 Consumo de corrente Transmiss o 11mA Vida til da bateria para uso t pico MCT 234 1 ano MCT 234 NB 3 anos Supervis o da bateria Bateria boa O LED acende continuamente na transmiss o Bateria fraca O LED pisca na transmiss o Nota Como a transmiss o feita apesar do estado da pilha o equipamento envia um sinal de pilha fraca ao receptor Temperatura de funcionamento De 0 a 49 C Dimens es MCT 234 53 5 x 31 5 x 12 5 mm MCT 234 NB 59 7 x 34 2 x 12 5 mm Peso incluindo a bateria 21 g Cor Negro Cumprimento das normas FCC Parte 15 EN 50131 1 EN 50131 3 EN 50131 6 Tipo C Grau 2 Classe Il Certificado MCT 234 pela Applica T 8 C MCT 234 NB n o foi avaliado para EN 3 3 TESTES E MANUTEN O 3 1 Teste a um equipamento novo Como o MCT 234 fornecido com a pilha j instalada este est praticamente pronto para testar se IMPORTANTE Antes de test lo ensine ao receptor o c digo de identifica o do MCT 234 como se indica no manual do receptor A Permane a a 3 m do receptor ou da central via r dio e pressione o bot o do MCT 234 marcado com um cadiado fechado Comprove que o LED acende B Assegure se que o receptor ou a central via r dio responde como programada e como est descrito no manual do receptor C Accione o comando de diversos lugares dentro da rea de cobertura do receptor para de
16. be replaced once every 1 year MCT 234 3 years MCT 234 NB or upon observing that the LED flickers when transmitting A Use a small Phillips screwdriver to open the miniature screw at the back of the unit Take care not to lose the screw B Put the unit down and extract the battery from its holder see Figure 2 Note Make sure the elastic pad within the cover remains in place Put it back in place if it falls off C Insert the new battery observe polarity D Test the unit by momentarily pressing one of the transmit switches The LED indicator should light Put the cover back on and re attach it with the screw 3 3 Cleaning The transmitter may get dirty if touched with greasy fingers Clean it only with a soft cloth or sponge moistened lightly with a mixture of water and mild detergent and wipe it dry immediately The use of abrasives of any kind is strictly forbidden Also never use solvents such as kerosene acetone or thinner 4 MISCELLANEOUS COMMENTS 4 1 Product Limitations Visonic Ltd wireless systems are very reliable and are tested to high standards However due to their low transmitting power and limited range required by FCC and other regulatory authorities there are some limitations to be considered A Receivers may be blocked by radio signals occurring on or near their operating frequencies regardless of the code selected B A receiver can only respond to one transmitted signal at a time C Wirel
17. e fun o de 4 bits associado ao bot o que se pressionou Da pr xima que se pressionar um bot o o transmissor emitir uma sequ ncia digital distinta da emitida anteriormente e o respectivo c digo da fun o O resultado de tudo isto que virtualmente imposs vel gravar ou copiar o c digo A alimenta o de funcionamento obtida da seguinte forma MCT 234 Bateria alcalina de 12V MCT 234 NB Bateria de l tio de 3V Um LED vermelho ilumina se durante a transmiss o sempre que a tens o da pilha seja superior a MCT 234 8 6 V MCT 234 NB 2 6V Se o LED piscar durante a transmiss o deve se substituir a pilha imediatamente O equipamento inclui o sinal de pilha fraca na transmiss o da mensagem digital Os receptores compativeis est o desenhados para identificar este sinal a activar a sa da correspondente Cada comando incorpora uma pequena argola D 2380 EPS MCT 234 MCT 234 NB User Guide 2 ESPECIFICACOES Frequ ncia MHz MCT 234 315 433 92 868 95 ou outras segundo requisitos locais UL foram estudados s com 315 MHz MCT 234 NB 869 2625 25KHz de largura de banda do canal Modulac o ASK activac o ON OFF Codifica o 28 bit ID 4 bits de c digo de fun o e 32 bits de c digo rotativo Durac o da transmiss o Cada press o num bot o provoca uma transmiss o at 2 segundos Alimentac o MCT 234 Bateria alcalina de 12 V 55mA h tipo GP 23A ou equivalente Para instalac es
18. ess equipment should be tested regularly to determine whether there are sources of interference and to protect against faults 4 2 Compliance with Standards This device complies with the essential requirements and provisions of Directive 1999 5 EC of the European Parliament and of the Council of 9 March 1999 on radio and telecommunications terminal equipment The 315 MHz model of this device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that may be received including interference that may cause undesired operation Note MCT 234 only was evaluated by UL MCT 234 NB was not evaluated by UL The user is cautioned that changes or modifications to the unit not expressly approved by Visonic Ltd could void the user s FCC authority to operate the equipment 4 3 Frequency Allocations for Wireless Devices in European EU Countries e 433 92 MHz has no restriction in any EU member state e 315 MHz is not allowed in any EU member state e 868 95 MHz wide band is allowed in all EU member states e 869 2625 MHz narrow band is not restricted in any EU member state WARRANTY Visonic Limited the Manufacturer warrants this product only the Product to the original purchaser only the Purchaser against defective workmanship and materials under normal use of the Product fo
19. o inclusive as pilhas ser o cobertos exclusivamente pelas respectivas garantias se existirem O Fabricante n o ser responsabilizado por qualquer tipo de danos ou de perdas de qualquer esp cie quer directas indirectas acidentais consequentes ou outras causados pela avaria do Produto causada por produtos acess rios perif ricos de terceiros incluindo as pilhas utilizados em conjunto com os Produtos Esta Garantia aplica se exclusivamente ao Comprador original e n o transmiss vel Esta Garantia cumulativa com e n o afecta os seus direitos legais Qualquer provis o nesta garantia contr ria Lei do estado ou pa s onde o Produto fornecido n o se aplica Aviso O utilizador deve respeitar as instru es de instala o e de opera o do Fabricante incluindo testes efectuados no Produto e em todo o seu sistema pelo menos uma vez por semana e tomar todas as precau es necess rias para sua seguran a para protec o da sua propriedade 1 08 MCT 234 NB GB US BATTERY SP BATERIA PT BATERIA GB US SCREW HOLE SP AGUJERO TORNILLO PT FURA O DO PARAFUSO GB US BUTTON PAD SP CUBIERTA TECLADO PT TECLADO D 2490 EP3 Ro D 2380 EPS MCT 234 MCT 234 NB User Guide
20. or contra defeito de fabrico ou de material em condi es de utiliza o normal do Produto por um per odo de doze 12 meses a partir da data da expedi o pelo Fabricante Esta Garantia est totalmente condicionada a que o Produto seja devidamente instalado mantido e operado em condi es normais de utiliza o de acordo com as instru es de instala o e de opera o recomendadas pelo Fabricante Os produtos com defeitos por qualquer raz o segundo o crit rio do Fabricante tais como instala o incorrecta n o cumprimento das instru es de instala o e de opera o recomendadas neglig ncia danos intencionais abuso ou vandalismo danos acidentais altera o ou sabotagem ou repara o efectuada por qualquer pessoa que n o o fabricante n o s o cobertos por esta Garantia O Fabricante n o garante que este Produto n o pode ser comprometido e ou violado ou que o Produto evite qualquer morte morte e ou ferimentos pessoais e ou danos materiais resultantes de arrombamentos roubo inc ndio ou outros ou que o Produto garantir em todos os casos alerta e protec o adequados Quando adequadamente instalado e mantido o Produto apenas reduz o risco de que tais eventos ocorram sem alerta e n o constitui nem garantia ou seguro de que tais eventos n o ocorram A PRESENTE GARANTIA EXCLUSIVA SUBSTITUINDO EXPRESSAMENTE AS DEMAIS GARANTIAS OBRIGA ES OU RESPONSABILIDADES ESCRITAS VERBAIS EXPRESSAS OU IMPL CITAS INCLUI
21. ot n espec fico el transmisor transmite una secuencia digital CodeSecureTM identificable por receptores CodeSecure compatibles y un c digo de funci n de 4 bits asociado al bot n que fue presionado La pr xima vez que sea presionado un bot n el transmisor transmitir una secuencia digital que difiere de la utilizada en la transmisi n previa y el respectivo c digo de funci n Como resultado la grabaci n de c digo maliciosa es virtualmente imposible La alimentaci n de funcionamiento se obtiene como sigue MCT 234 Bater a alcalina de 12V MCT 234 NB Bater a de litio de 3V Un LED rojo luce durante la transmisi n hasta que el voltaje de la bater a exceda de MCT 234 8 6 V MCT 234 NB 2 6V Si el LED parpadea durante la transmisi n la bater a debe ser sustituida sin retraso Adem s un informe de baja bater a sera transmitido con el mensaje digital de salida Se dise an receptores compatibles para identificar este informe e impulsar la salida correspondiente Cada transmisor se suministra con un peque o llavero 2 ESPECIFICACIONES Frequencia MHz MCT 234 315 433 92 868 95 u otros seg n requerimientos locales UL se ha estudiado s lo a 315 MHz MCT 234 NB 869 2625 25KHz de ancho de banda del canal Modulaci n ASK activaci n ON OFF Codificaci n 28 bit ID 4 bits de c digo de funci n y 32 bits de c digo rotativo Duraci n de la transmisi n Cada presi n del bot n provoca una t
22. r a period of twelve 12 months from the date of shipment by the Manufacturer This Warranty is absolutely conditional upon the Product having been properly installed maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions Products which have become defective for any other reason according to the Manufacturers discretion such as improper installation failure to follow recommended installation and operational instructions neglect willful damage misuse or vandalism accidental damage alteration or tampering or repair by anyone other than the manufacturer are not covered by this Warranty The Manufacturer does not represent that this Product may not be compromised and or circumvented or that the Product will prevent any death and or personal injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection The Product properly installed and maintained only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS OR LIABILITIES WHETHER WRITTEN ORAL EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE IN NO CASE SHALL THE MANUFACTURER BE LIABLE
23. ransmisi n de hasta 2 segundos Alimentaci n MCT 234 Bater a alcalina de 12 V 55mA h tipo GP 23A o equivalente Para instalaciones UL utilice bater a fabricada por GP MCT 234 NB Bater a de 3V CR 2032 Consumo de corriente Transmisi n 11mA Vida til de la bater a para uso t pico MCT 234 1 a o MCT 234 NB 3 a os Supervisi n de la bater a Bater a buena El LED luce continuamente en transmisi n Baja bater a El LED parpadea en transmisi n 2 Nota Si la transmisi n es todav a possible a pesar de la condici n de la bater a la unidad enviar una se al de baja bater a al receptor Temperatura de funcionamiento De 0 to 49 C Dimensiones MCT 234 53 5 x 31 5 x 12 5 mm MCT 234 NB 59 7 x 34 2 x 12 5 mm Peso incluyendo bateria 21 g Color Negro Cumplimiento de normas FCC Parte 15 EN 50131 1 EN 50131 3 EN 50131 6 Typo C Grado 2 Clase Il Certificado para MCT 234 por Applica T amp C MCT 234 no ha sido verificado para EN 3 PRUEBAS Y MANTENIMIENTO 3 1 Probando una unidad nueva Ya que el MCT 234 se suministra con la bateria ya instalada la unidad esta practicamente lista para ser probada IMPORTANTE Antes de probarla ense e al receptor el c digo ID del MCT 234 como se instruye en el manual de programaci n del receptor A Sit ese a 3 m del receptor o central inal mbrica y presione el bot n del MCT 234 marcado con un icono de un candado cerrado Verifique que el LED
24. risdicciones no se permite la exclusi n o limitaci n de los da os indirectos o consecuenciales por lo que estas limitaciones podr an no resultar aplicables en ciertas circunstancias El Fabricante no tendr ning n tipo de responsabilidad a ra z de corrupci n y o mal funcionamiento de cualquier equipo de telecomunicaciones o electr nico o de cualquier programa Las obligaciones del Fabricante bajo esta garant a se limitan de manera exclusiva a la reparaci n y o sustituci n a discreci n del Fabricante de cualquier producto o parte del mismo que se demuestre averiado Cualquier reparaci n y o sustituci n no extender el periodo de garant a original El Fabricante no ser responsable de los costes de desmontaje y o reinstalaci n Para ejercitar esta garant a el Producto se deber devolver al Fabricante con el flete prepagado y asegurado Todos los costes de flete y seguro son responsabilidad del Fabricante y no se incluyen en esta garant a Esta garant a no se modificar cambiar ni ampliar y el Fabricante no autoriza a ninguna persona a que act e en representaci n suya para modificar cambiar o ampliar esta garant a Esta garant a se aplicar solamente al Producto Todos los productos accesorios o acoplamientos de terceras partes que se utilicen conjuntamente al Producto incluyendo bater as estar n cubiertos exclusivamente por sus propias garant as si existe alguna El Fabricante no ser responsable de ning n da o o
25. suario para hacer funcionar el equipo 4 3 Asignaciones de frecuencia para dispositivos inal mbricos en pa ses europeos UE e 433 92 MHz no tiene restricci n en ning n estado miembro de la UE e 315 MHz no est permitido en ning n estado miembro de la UE e 868 95 MHz banda ancha est permitida en todos los estados miembros de la UE e 869 2625 MHz banda estrecha no est limitado en ning n estado miembro de la UE I Declaracion de Reciclaje de Producto R A E E Para informacion relacionada con el reciclaje de este producto debe contactar con la compa a a la que compr en origen Si usted va a desechar este producto y no lo va a devolver para reparaci n debe asegurar que es devuelto como estableci su proveedor Este producto no se tira con la basura diaria Europeo Directiva 2002 96 EC de Residuos de Aparatos El ctricos y Electr nicos No obstante si se hace responsable al Fabricante ya sea directa o indirectamente de cualesquiera p rdidas o da os bajo esta garant a limitada LA M XIMA RESPONSABILIDAD DEL FABRICANTE SI ALGUNA EN NING N CASO EXCEDER EL PRECIO DE COMPRA DEL PRODUCTO y dicho precio se fijar como da os liquidados y no como una multa y constituir el remedio completo y exclusivo contra el Fabricante Al aceptar la entrega del Producto el Comprador acepta las citadas condiciones de venta y garant a y el Comprador reconoce haber sido informado de las mismas En algunas ju
26. sult malicious code grabbing is virtually impossible Operating power is obtained as follows MCT 234 12V alkaline battery MCT 234 NB 3V Lithium battery A red LED lights during transmission as long as the battery voltage exceeds MCT 234 8 6 V MCT 234 NB 2 6V If the LED flashes during transmission the battery must be replaced without delay In addition a low battery report will be transmitted with the outgoing digital message Compatible receivers are designed to identify this report and operate a corresponding output Each transmitter is supplied with a small key ring 2 SPECIFICATIONS Frequency MHz MCT 234 315 433 92 868 95 or other per local requirements UL has only investigated at 315 MHz MCT 234 NB 869 2625 25KHz channel bandwidth Modulation ASK ON OFF keying Coding 28 bit ID 4 bit function code and 32 bit rolling code Transmission Duration Each button press causes transmission for up to 2 seconds Power Supply MCT 234 12 V alkaline battery 55mA h type GP 23A or equivalent For UL installations use battery manufactured By GP MCT 234 NB 3V battery CR 2032 Current Consumption Transmission 11mA Battery Life Expectancy For typical use MCT 234 1 year MCT 234 NB 3 years Battery Supervision Good battery LED lights steadily upon transmission Low battery LED flickers upon transmission Note If transmission is still possible despite the battery condition the unit will send
27. terminar se existem zonas mortas transmiss es que sejam bloqueadas por paredes ou objectos grandes ou pela pr pria estrutura do edif cio Nota Caso tenha zonas mortas ou as zonas que sejam de dif cil capta o a causar problemas reposicione o receptor central para melhorar a recep o 3 2 Troca da pilha A pilha deve ser trocada uma vez por ano MCT 234 3 anos MCT 234 NB ou quando se detecte que o LED pisca durante a transmiss o A Use uma chave philips pequena para retirar o parafuso da parte de tr s do equipamento Tenha cuidado para n o perder o parafuso B Retire a tampa posterior do comando e extraia a pilha do compartimento ver a fig 2 Nota Assegure se que o teclado de borracha permanece no sitio caso ca a volte a coloc lo no sitio C Coloque a pilha nova observando a polaridade D Teste o equipamento pressionando momentaneamente um dos bot es O LED deve acender E Volte a colocar a pilha e aperte o parafuso 3 3 Limpeza O comando pode sujar se ao ser utilizado com as m os sujas Limpe o somente com um pano ou uma esponja humedecida com uma mistura de gua e um pouco de detergente e ap s a limpeza seque de imediatamente o equipamento O uso de abrasivos de qualquer tipo est estritamente proibido Tal como o uso de dissolventes como petr leo ou acetona GARANTIA A Visonic Limited o Fabricante garante este produto o Produto s ao comprador original o Comprad
Download Pdf Manuals
Related Search
Related Contents
910.100.310 REV00 MANUALE QUEEN 210:modello manuale.qxd 「取扱説明書」 HFRLシリーズ Test Gear - The R-390A Frequently Asked Questions Page Ultron US-11 ll-2000 man english.qxd Copyright © All rights reserved.
Failed to retrieve file