Home

BUSCAPOLOS AC NO-CONTACTO / NON-CONTACT

image

Contents

1. DELAI DE 7 JOURS A PARTIR DE LA DATE D ACHAT SELLO STAMP CACHET EJEMPLAR PARA EGA MASTER COPY FOR EGA MASTER EXEMPLAIRE POUR EGA MASTER CERTIFICADO DE GARANTIA GUARANTEE CERTIFICATE CERTIFICAT DE GARANTIE UA EN IAM LE esamus ii i i a A N DE SERIE A ERIEIN INO SERIE AA Ag a a a DISTRIBUIDOR 7 DISTRIBUTOR DISTRIBUTEUR css dois Odio een EGA MASTER GARANTIZA AL COMPRADOR DE ESTA MAQUINA LA GARANTIA TOTAL DURANTE 12 MESES DE LAS PIEZAS CON DEFECTOS DE FABRICACION ESTA GARANTIA NO CUBRE AQUELLAS PIEZAS QUE POR SU USO NORMAL TIENEN UN DESGASTE PARA OBTENER LA VALIDEZ DE LA GARANTIA ES ABSOLUTAMENTE IMPRESCINDIBLE QUE COMPLETE Y REMITA ESTE DOCUMENTO A EGA MASTER DENTRO DE LOS SIETE DIAS A PARTIR DE LA FECHA DE COMPRA EGA MASTER GUARANTEES TO THE BUYER OF THIS MACHINE THE TOTAL WARRANTY DURING 12 MONTHS OF THE PIECES WITH MANUFACTURING FAULTS THIS GUARANTEE DOES NOT COVER THOSE PIECES WORN OUT DUE TO A NORMAL USE IN ORDER TO OBTAIN THE VALIDITY OF THIS WARRANTY IT IS ABSOLU TELY NECESSARY TO FULFILL THIS DOCUMENT AND RESEND IT TO EGA MASTER WITHIN 7 DAYS FROM SALE DATE EGA MASTER GARANTIE A L ACHETEUR DE CETTE MACHINE LA GARANTIE TOTALE PENDANT 12 MOIS DES PIECES AVEC DEFAUTS DE FABRICATION CETTE GARANTIE NE COUVRE PAS LES PIECES QUE PAR UN USAGE NORMAL SOIENT DETERIOREES POUR OBTENIR LA VALIDITE DE LA GARANTIE IL EST ABSOLUMENT IMPERATIF COMPLETER ET ENVOYER CE DOCUMENT EGA MASTER DANS UN DELAI DE 7 J
2. unit will auto power off when it is not used for around 3 minutes The beeper sounds 2 times continuously and then one long beep means the unit is power off 5 Press and hold the power button for two seconds to turn the unit off there will be one second long beep li BATTERY INDICATION gt The LED will not flash when you turn the unit on or during checking if the battery is less than 2V The beep sounds will still have but may be weaker MAINTENANCE i Battery Replacement 1 Disconnect the unit from the circuit 2 One hand holds the unit Place another hand s thumb on the probe cap as the figure below Figure 1 3 Pull back the back housing as the figure below Figure 2 4 Replace the batteries observe polarity 2 x1 5V AAA 5 Push back the back housing IMPORTANT The maker will not take responsibility for damage or malfunction as a result of the device being incorrectly used or applied for a purpose for whith it was not intended According to Waste Electrical and Electronic Equipment directive WEEE these ones must be collected and arranged separately If you have to throw them out please do not use the usual rubbish Please contact your distributor for free recycling GUARANTEE A The maker guarantees to the device owner 12 months against any manufacture defect This guarantee do not cover the parts wich are consumables Note to apply the guarantee its necesary to send th
3. OPERATING INSTRUCTIONS MANUAL DE INSTRUCCIONES ART IN INNOVATION BUSCAPOLOS AC NO CONTACTO NON CONTACT AC VOLTAGE DETECTOR EGA COD 51256 ESPA OL ENGLISH GARANT A GUARANTEE TVS lt a ISO 14001 2004 ISO 9001 2008 ESPANOL INFORMACION GENERAL Este Manual contiene informacion en materia de seguridad y precauciones a tener en cuenta Lea con atenci n todas las instrucciones y la informaci n de seguridad de este manual antes utilizar esta herramienta No entender el modo de operar de manera segura podr a ocasionar un accidente causando lesiones graves o incluso la muerte El detector de tensi n tiene como objetivo comprobar la existencia de tensi n alterna avisando al usuario mediante la emisi n de un sonido y el parpadeo de un LED INFORMACI N DE SEGURIDAD Esta unidad cumple con las normas EN61010 1 UL61010 1 y N 61010 1 CASC 22 1 requisito de medici n de la seguridad en el grado de contaminaci n 2 categor a de sobretensi n art IV 1000V CAT IV nivel de la fuente primaria l neas a reas sistemas de cable etc Algunos ejemplos cables medidores transformadores y otros equipos de exterior pertenecientes a la compa a el ctrica Utilice la unidad s lo como se especifica en este manual de lo contrario la protecci n proporcionada por el detector puede verse afectada e No utilice la unidad si se encuentra mojada da ada o no funciona correctamente e No aplique m s
4. OURS A PARTIR DE LA DATE D ACHAT SELLO STAMP CACHET EJEMPLAR PARA EL CLIENTE COPY FOR THE CUSTOMER EXEMPLAIRE POUR LE CLIENT E ISO 14001 2004 Q CERT ISO 9001 2008 C ZORROLLETA 11 POL IND JUNDIZ 01015 VITORIA SPAIN P O B APTDO 5005 TEL 34 945 290 001 FAX 34 945 290 141 master egamaster com www egamaster com
5. cienda la unidad pulsando el bot n de encendido una vez la unidad emitira un pitido y el LED parpadear dos veces Cuando la unidad esta en modo de espera el LED parpadea dos veces cada 1 5 segundos 2 Coloque la punta de la sonda en el circuito o cerca del mismo Un pitido y el parpadeo del LED indican la presencia de voltaje 90Vac a 1000VAC 3 Para desactivar el pitido podr pulsar el bot n de encendido una vez un pitido indicar que la alarma sonora est desactivada Estando desactivada la alarma s lo el LED parpadear durante las comprobaci nes Es una manera de ahorrar bater a Pulse el bot n para alternar entre el modo con se al ac stica y el modo silencio Un Beep modo silencio Dos Beep desactivado modo silencio 4 Con el fin de ahorrar bater a la unidad dispone de apagado autom tico si no se utiliza durante 3 minutos Dos pitidos cortos y un posterior pitido largo indicar n que la unidad se ha apagado 5 Mantenga pulsado el bot n de encendido durante dos segundos para apagar la unidad Un pitido largo nos indicar que el buscapolos est apagado li ESTADO DE LA BATERIA as El LED no parpadear cuando se encienda el aparato o durante su utilizaci n si la bater a es inferior a 2V Las senales acusticas seran mas d biles MANTENIMIENTO gt Sustituci n de las pilas 1 Desconecte la unidad 2 Con una mano sujete la parte roja de la unidad Cologue el pulgar de la otra mano en la ta
6. e GUARANTEE CERTIFICATE duly filled within one week after purchased the machine to the maker 10 Ets CERTIFICADO DE GARANTIA A GUARANTEE CERTIFICATE ART IN INNOVATION CERTIFICAT DE GARANTIE ARR COLO TEATAR OLE nenne en IDE SERIE OEREN A AN nen se la i t i Aa DISTRIBUIDOR DISTRIBU TOR DISTRIBUTED sasas ais ii i i EEEN Pl COUNTRY PAVOS ordinaria a BL EGA MASTER GARANTIZA AL COMPRADOR DE ESTA MAQUINA LA GARANTIA TOTAL DURANTE 12 MESES DE LAS PIEZAS CON DEFECTOS DE FABRICACION ESTA GARANTIA NO CUBRE AQUELLAS PIEZAS QUE POR SU USO NORMAL TIENEN UN DESGASTE PARA OBTENER LA VALIDEZ DE LA GARANTIA ES ABSOLUTAMENTE IMPRESCINDIBLE QUE COMPLETE Y REMITA ESTE DOCUMENTO A EGA MASTER DENTRO DE LOS SIETE DIAS A PARTIR DE LA FECHA DE COMPRA EGA MASTER GUARANTEES TO THE BUYER OF THIS MACHINE THE TOTAL WARRANTY DURING 12 MONTHS OF THE PIECES WITH MANUFACTURING FAULTS THIS GUARANTEE DOES NOT COVER THOSE PIECES WORN OUT DUE TO A NORMAL USE IN ORDER TO OBTAIN THE VALIDITY OF THIS WARRANTY IT IS ABSOLU TELY NECESSARY TO FULFILL THIS DOCUMENT AND RESEND IT TO EGA MASTER WITHIN 7 DAYS FROM SALE DATE EGA MASTER GARANTIE A L ACHETEUR DE CETTE MACHINE LA GARANTIE TOTALE PENDANT 12 MOIS DES PIECES AVEC DEFAUTS DE FABRICATION CETTE GARANTIE NE COUVRE PAS LES PIECES QUE PAR UN USAGE NORMAL SOIENT DETERIOREES POUR OBTENIR LA VALIDITE DE LA GARANTIE IL EST ABSOLUMENT IMPERATIF COMPLETER ET ENVOYER CE DOCUMENT EGA MASTER DANS UN
7. erous voltage do not use any part of the body to touch the tested inductor e When carrying out checking keep your fingers behind the probe tip finger guards a Symbols used on the Meter and in this manual are explained below Double Insulated Warning Refer to the Operating Manual i INTERNATIONAL ELECTRICAL SYMBOLS Danger of electric shock Conforms to Standards of European Union i SPECIFICATIONS e Indicators LED and Beep e Voltage range 90VAC 1000VAC e Measurement Category IV 1000V per IEC61010 e Temperature gt Operating 10 50 C gt Storage 10 50 C e Humidity lt 95 e Altitude 2000m e Pollution Degree 2 e Battery 2x 1 5V AAA OPERATION 1 Turn the unit on by pressing the power button once the unit beeps and LED flashes two times When the unit is under standby mode the LED keeps flashing two times in every 1 5 seconds 2 Place the probe tip on or near the circuit or unit to be tested Beep and flashing LED indicate the presence of voltage 90VAC to 1000VAC 3 To turn off the beeper you could press the power button once after turning on the unit then you will hear a beep sound indicating the beeper is off After the beeper is off only LED will flash during checking This way could save battery Press power button to toggle between beeper mode and silent mode Beep two times enters beeper mode while beep one time enters silent mode 4 In order to save battery the
8. his tool could result in an accident causing serious injury or death The non contact AC voltage detector is intended to check for the presence of AC voltage signaling the user with a beep and a flashing LED This unit complies with the standards EN61010 1 UL61010 1 CASC 22 1 No 61010 1 safety measurement requirement in pollution degree 2 overvoltage category CAT IV 1000V CAT IV Primary supply level overhead lines cable systems etc Some examples include cables meters transformers and other exterior equipment owned by the power utility Use the unit only as specified in this operating manual otherwise the protection provided by the unit may be impaired e Do not use the unit if it is wet damaged or cannot operate correctly e Do not apply more than the rated voltage between the probe tip and earth ground e When the unit working at voltage over 30V in AC special care should be taken for there is danger of electric shock e Follow the local countries safety requirements and standards A Warning e This unit is only designed for the specialist who has certain technical knowledge to use e This unit is intended to check for the presence of AC voltage the voltage range is 90 1000V Make sure the tested inductor possible voltage range before carrying out checking e When you cannot sure the tested inductor voltage range the unit does not have any response It does not mean the tested inductor does not have dang
9. pa gris oscura del buscapolos tal y como se indica en la siguiente figura Figure 2 4 Cambie las pilas observe la polaridad 2 x1 0 5 V AAA 5 Presione de nuevo la tapa trasera Tr a IMPORTANTE El fabricante no se responsabiliza de los da os o mal funcionamiento del aparato en caso de que no se use correctamente o se haya utilizado para trabajos para los que no est dise ado Seg n la directiva sobre residuos el ctricos de aparatos el ctricos y electr nicos RAEE stos deber n recogerse y tratarse por separado Si en el futuro tiene que deshacerse de este pro ducto no se deshaga de l junto con la basura dom stica P ngase en contacto con su distribuidor para proceder a su reciclaje de manera gratuita cuando sea posible El fabricante garantiza al comprador de este aparato la garantia total durante 12 meses de las piezas con defectos de fabricaci n Esta garant a no cubre aquellas piezas que por su uso normal tienen un desgaste Nota para obtener la validez de la garant a es absolutamente imprescindible que complete y remita al fabricante el documento de CERTIFICADO DE GARANTIA dentro de los siete dias a partir de la fecha de compra ENGLISH This Operating Manual covers infomation on safety and cautions Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Failure to understand how to safely operate t
10. voltaje del nominal e Cuando la unidad se someta a m s de 30 V de tensi n en CA debe tenerse especial cuidado porque habr peligro de descarga el ctrica e Siga los requerimientos de los pa ses locales y normas de seguridad A Advertencias e Esta unidad s lo est dise ada para especialistas que tengan ciertos conocimientos t cnicos sobre su uso e Esta unidad est dise ada para detectar la existencia de voltaje de CA El rango de voltaje es de 90 1000V Aseg rese antes de realizar cualquier comprobaci n de que todas las pruebas se realizan dentro del rango se alado e Cuando se utiliza el buscapolos fuera del rango de voltaje indicado la unidad no tiene respuesta Esto no significa que el inductor probado no tenga tensi n y por lo tanto no utilice partes del cuerpo para tocarlo e Al realizar comprobaciones mantenga los dedos en las protecciones Los simbolos utilizados tanto en el medidor como en este manual se explican a continuaci n Doble aislamiento Advertencia Remitirse al manual de instrucciones Peligro por descarga electrica RE Conforme a los estandares de la Union Europea e Los indicadores LED y del sonido beep e Rango de voltaje OVAC 1000VAC e Categor a de medici n IV 1000V por IEC61010 e Temperatura gt De operacion 10 50 C gt De almacenamiento 10 50 e Humedad lt 95 e Altitud 2000m e Grado de contaminaci n 2 e Bater a 2x 1 5V AAA 1 En