Home

10. Especificaciones técnicas Peso

image

Contents

1. Place the cuff over the left upper arm so that the tube is closer to your lower arm Lay the cuff on the arm as illustrated Make certain that the lower edge of the cuff lies approximately 3 4 to 1 2 to 3cm above the elbow and that the tube is closer to the inner side of the arm Important The 1 white mark on the cuff must lie exactly over the artery which runs down the inner side of the arm tube 1 white mark proper cuff placement inside of inner arm Tighten the cuff by pulling the end and close the cuff by affixing the velcro There should be little free space between the arm and the cuff You should able to fit 2 fingers between your arm and the cuff Clothing must not restrict the arm Any piece of clothing which does must be removed Lay your arm on a table palm upwards so that the cuff is at the same height as the heart Make sure that the tube is not kinked Remain seated quietly for two minutes before you be gin the measurement Comment If it is not possible to fit the cuff to your left arm it can also be placed on your right arm However all measure ments should be made using the same arm I 2 3 cm B tube gt lt cuff at heart level Sit quiet Don t move during measurement Cuff on right arm 5 4 Measuring procedure After the cuff has been appropriately positioned the measurement can begin a Switch the instrument on by pressing the ON OFF Memory b
2. 300 mmHg aparece Hl en la pantalla y se oye una se al de advertencia La presi n del brazalete debe ser eliminada inmediatamente mediante la v lvula de escape r pida de la perilla de la bomba En cuanto el brazalete tenga la presi n adecuada y la medici n est en curso siga los pasos d e 5 6 Interrupci n de la medici n Si por alguna raz n es necesario interrumpir la medici n de la tensi n arterial p ej el paciente no se encuentra bien presione la v lvula de desinflado r pido de la perilla El aparato disminuye entonces de forma inmediata la presi n del brazalete 5 7 Memoria indicaci n en pantalla del ltimo valor medido El tensi metro memoriza autom ticamente el ltimo valor medido Al presionar el bot n de MEMORIA MEMORY 3 segundos el ltimo valor medido aparecer en la pantalla t Informacion adicional 3 sec o te D No deben efectuarse las mediciones una inmediatamente a continuaci n de la otra ya que de lo contrario los resultados pueden verse falsificados Espere por ello durante varios minutos en una posici n relajada sentado o acostado antes de repetir la medici n 5 4 Procedimiento de medici n Una vez colocada la mu equera correctamente puede comenzar la medici n a b c d e Ponga en marcha el aparato presionando el bot n 0 1 y Memoria El tubo no deber a estar atin conectado al aparato En la pantalla ap
3. wut wh Lt ww 4 Puesta en funcionamiento del monitor de tensi n arterial 4 1 Colocaci n de las pilas Una vez desempaquetado el aparato inserte primero las pilas El compartimento de la bater a est situado en la parte inferior del aparato vea la ilustraci n a Retire la tapa como se indica en la figura b Inserte las pilas 4 x tama o AA 1 5V teniendo en cuenta la polaridad indicada c Si aparece un mensaje de advertencia sobre las pilas en la pantalla las pilas est n descargadas y deben ser sustituidas por otras nuevas Atenci n e Una vez que aparece el mensaje de advertencia sobre la bater a queda bloqueado el aparato hasta que se sustituyen las pilas e Use pilas de 1 5V AA de larga duraci n o alcalinas No se recomienda el uso de acumuladores de 1 2 V e Sino va a usar el monitor de tensi n arterial por un largo periodo de tiempo retire las pilas del aparato Comprobaci n funcional Mantenga apretado el bot n 0 I para comprobar todos los elementos de la pantalla Si funciona correctamente deben aparecer todos los segmentos 4 2 Conexi n del tubo e Brazalete AC 1 brazalete de 1 tubo conector en T Ajuste o compruebe las diferentes conexiones del tubo con el brazalete el aparato y la perilla de la bomba tal y como aparece en el diagrama 21 D Constituci n f sica Haga deporte de forma regular Elija deportes que requieran vigor y evite aquello
4. D Your Physical condition e After a medical examination and with your doctor s approval and direction exercise e Choose sports which require stamina and avoid those which require strength e Avoid reaching the limit of your performance e With previous illnesses and or an age of over 40 years please consult your doctor before beginning your exercise routine You must receive advise regarding the type and extent of exercise that is appro priate for you 3 Components of your blood pressure monitor Your Medline upper arm semi automatic blood pressure monitor consists of a Measuring unit Display ON OFF Cuff connection Memory button b Cuffs Type MDS9872 for arm circumference 22 30 cm 8 16 11 15 Type MDS9873 for arm circumference 30 38 cm 11 16 15 pressure release valve connect cuff to unit pumping bulb T Connector cuff Please Note If the cuff does not fit properly call Medline and order the appropriate size 5 5 5 Inflado adicional Cuando el brazalete no se ha inflado lo suficiente la medici n se interrumpe y tras unos segundos aparece en la pantalla una flecha que se ala hacia arriba Indica que es neceario inflar m s el brazalete como m nimo hasta alcanzar 20 mmHg por encima del valor anterior La instrucci n de inflar m s puede aparecer varias veces s la presi n alcanzada todav a no es suficiente Atenci n Si el brazalete se ha hinchado demasiado por encima de
5. MDS9873 for arm circumference 30 38 cm 11 8 16 15 Blood pressure is subject to fluctuations even in healthy people Comparable measurements always require the same conditions Quiet conditions If fluctuations are larger than 15 mmHg and or you hear irregular pulse tones consult your doc tor In order to receive market clearance from governmental bodies this device was been subjected to strict clinical tests The computer program used to measure blood pressure values was tested by experienced car diac specialists in Germany The manufacture of your Medline Blood Pressure monitor is in accordence with the terms of the European standard for blood pressure measuring devices see technical data under the supervision of the Technical Monitoring Association Essen RWTiV Essen Tensi metro semi autom tico Instrucciones de uso
6. Si es necesario utilice un almohad n de apoyo Si la arteria braquial se encuentra considerablemente m s baja alta que el coraz n se medir una tensi n arterial err nea m s alta baja Cada 15cm de diferencia en altura da lugar a un error de medici n de 10mmHg Brazaletes demasiado estrechos o cortos pueden dar falsas mediciones Seleccionar el brazalete adecuado es de gran importancia El tama o del brazalete depende de la circunferencia del brazo medida en el centro Los tama os permitidos vienen impresos en el brazalete Si ste no resulta adecuado para su uso por favor contacte con el establecimiento donde lo adquiri Nota Utilice solamente brazaletes originales cl nicamente comprobados Un brazalete mal ajustado o si la c mara de aire asoma por ambos lados del mismo pueden ocasionar resultados falsos Si se repiten las mediciones la sangre se acumular en el brazo correspondiente lo que puede dar lugar a resultados err neos Por ello para efectuar la medici n de la tensi n arterial de forma correcta no la repita hasta pasados 5 minutos o hasta despu s de haber mantenido el brazo en alto para permitir que la sangre acumulada fluya transcurridos al menos 3 minutos 22 5 3 Fitting the cuff a b c d e f g Pass the end of the cuff through the flat metal ring so that a loop is formed The Velcro closer must be facing outwards Ignore this step if the cuff has already been prepared
7. by sitting in an armchair in a quiet atmosphere for about ten minutes before measurement e Remove any garment that fits closely to your upper arm e Always measure on the same arm normally left e Always perform measurements at the same time of day since blood pressure changes during the course of the day 5 2 Common sources of error Note Comparable blood pressure measurements always require the same conditions These are normally quiet conditions e Efforts by the patient to support the arm can increase the blood pressure Make sure you are in a com fortable relaxed position and do not activate any muscles in the measurement arm during measure ment Use a cushion for support and rest your arm on a table e fthe upper arm artery lies considerably lower or higher than the heart a false higher or lower blood pressure will be measured A variation of 6 between cuff and heart level can result in a reading error of or 10mm Hg e Cuffs that do not fit properly result in false measurement values Selecting the correct cuff is extremely important The cuff size is dependent upon the circumference or distance arround your upper arm mea sured in the center The permissible range is printed on the cuff If this is not suitable for your use please contact your dealer Note Use only clinically approved Medline Cuffs Medline cuffs are specially manufactured and tested e A loose cuff or a sideways protruding air pocket causes fa
8. mmHg without a measurement taking place The Release valve was pressed during the measure ment Re start ERR 3 Inflation of the cuff takes too long The cuff is not correctly seated or the hose connection is not tight Check connections and repeat ERR 5 The difference between systolic and diastolic is excessive Mea sure again carefully following proper cuff procedures and ensure measurement is taken under quiet conditions Other possible errors and solutions If problems occur when using the device the following points should be checked Situation Solution The display remains empty when the instrument is e Check whether the batteries are installed with switched on although the batteries are in place the correct polarity The display is not working properly e f the display is unusual remove the batteries and then exchange them for new The pressure does not rise although you are e Check the connection of the cuff tube and pumping the bulb connect properly The device frequently fails to measure the blood 1 Fit the cuff correctly on the arm Section 5 3 pressure values or the values measured are too 2 Before starting measurement make sure low or high the cuff is not too tight and clothing is not exert ing pressure on the arm Take articles of clothing off if necessary 3 Measure again in complete peace and quiet Every measurement results in different values e Blood pressure changes con
9. 10 Especificaciones t cnicas Peso Dimensiones Temperatura de almacenamiento Humedad Temperatura de funcionamiento Pantalla M todo de medicion Sensor de presion Alcance de medici n SYS DIA pulso L mites de indicaci n de la presi n de la mu equera Memoria Resoluci n de las medidas Exactitud presi n pulso Fuente de Energ a Accesorios Areserva de modificaciones t cnicas 30 265 g pilas incluidas 131 x 174 x 73 mm 5 a 50 C 15 a 85 de humedad relativa como m ximo 10 a 40 C Pantalla LCD display de cristal l quido oscilom trico capacitivo 30 a 280 mmHg 40 a 200 por minuto 0 299 mmHg almacenamiento autom tico del ltimo valor medido 1 mmHg 3 mmHg 5 de la lectura 4 celulas secas pilas UM 3 tama o AA 1 5 V brazalete modelo MDS9872 para brazos de circunferencia 22 30 cm brazalete modelo MDS9873 para brazos de circunferencia 30 38 cm MEDLINE Medline Semi Automatic Blood Pressure Monitor Model MDS2002 For upper arm Manual inflate with bulb auto deflate Instruction Manual Tensi metro autom tico Instrucciones de uso PLEASE NOTE THIS MEDICAL INSTRUMENT MUST BE USED ACCORDING TO IN STRUCTIONS TO ENSURE ACCURATE READINGS Questions Call MEDLINE toll free at 1 800 950 0128 Medline Semi automatic Upper Arm Blood Pressure Monitor Instruction Manual Table of contents 1 Introduction 1 1 1 2 2 Fe
10. 7 Care and maintenance Do not expose the device to either extreme tempera a d e f tures humidity dust or direct sunlight The cuff contains a sensitive air tight bubble Handle this carefully and avo twisting or buckling id all types of stress through Clean the device with a soft dry cloth Do not use gas thinners or similar so removed carefully wi The cuff must not b Clothes washer or Handle the tube care edges vents Spots on the cuff can be h a damp cloth and soapsuds e washed in a dishwasher submerged in water ully Do not pull on it Do not al l low the tubing to kink and keep away from sharp Do not drop the instrument or treat it roughly in any way Avoid strong vib Never open the device This invalidates the manu facturers warranty 8 Warranty rations The Medline blood pressure monitor MDS2001 is guaranteed for 2 years from date of purchase This warranty includes the instrument only The cuff is covered for 1 year from the date of purchase The warran ty does not apply to damage caused by improper handling accidents not following the operating instruc tions or alterations made to the instrument by third parties Batteries or damage from old batteries is not covered by the warranty Please note Unlike gauge type devices this unit generally does not require calibration You must consult your dealer if there are technical problems with this blood
11. a del coraz n Vigile de no doblar el tubo g Permanezca sentado tranquilamente duante dos minutos antes de empezar la medici n Nota En el caso de que no sea posible colocar el brazalete en el brazo izquierdo se podr colocar en el derecho Lo importante es que la medici n se haga siempre en el mismo brazo 23 5 Desarrollo de una medici n 5 5 1 Antes de la medici n Evite comer fumar as como cualquier forma de ejercicio directamente antes de la medici n Todos estos factores influyen sobre el resultado de la medici n Busque y encuentre tiempo para relajarse sentado en un sill n en una atm sfera tranquila durante unos diez minutos antes de la medici n Si lleva cualquier prenda que le oprime el brazo qu tesela Efect e la medici n siempre en la misma mu eca normalmente la izquierda Intente efectuar las mediciones de forma regular a la misma hora del d a ya que la tensi n arterial se modifica en el curso del d a 2 Fuentes de error comunes Tenga en cuenta Para poder comparar los resultados de las mediciones de la tensi n arterial se requiere que las condiciones sean las mismas Estas son normalmente condiciones de tranquilidad Los esfuerzos del paciente para mantener el brazo en posici n pueden aumentar la tensi n arterial Aseg rese de estar en una posici n c moda y relajada y no active ning n m sculo del brazo en el que se est efectuando la medici n durante la misma
12. aci n concreta por retroalimentaci n a trav s del sistema nervioso Para ajustar la ensi n arterial se modifican la potencia y la frecuencia cardiacas pulso as como la anchura de los vasos sangu neos Esto ltimo se efect a mediante los m sculos de las paredes de los vasos sangu neos El nivel de la arterial tensi n arterial cambia peri dicamente durante la actividad cardiaca durante a impulsi n de la sangre sistole el valor es m ximo valor sist lico de la tensi n arterial al final del periodo de relajaci n del coraz n di stole es m nimo valor diast lico de la tensi n arterial Para evitar ciertas enfermedades los valores de la tensi n arterial deben estar situados entre unos valores mite determinados 2 2 Cu les son los valores normales La tensi n arterial es excesiva si en reposo la presi n diast lica es superior a 90 mmHg y o la presi n arterial sist lica es superior a 160mmHoa En este caso consulte con su m dico de forma inmediata Valores de este nivel durante largo tiempo ponen en peligro su salud debido al da o progresivo asociado que supone para los vasos sangu neos de su cuerpo Si el valor sist lico de la tensi n arterial est entre 140 mmHg y 160 mmHg y o el valor diast lico de la tensi n arterial est entre 90 mmHg y 95 mmHg consulte igualmente con su m dico Es m s ser necesario efectuar autocontroles de forma regular Con valores de la tensi n arterial muy bajo
13. arece lo siguiente durante 2 segundos Diagrama Un corto pi pi piip indica que el aparato ha equilibrado su presi n con la ambiental y la medici n puede empezar Aparece 0 en la pantalla Inserte el conector en T o el extremo libre del tubo en el lateral izquierdo del aparato Apriete la perilla de la bomba con la mano libre e infle el brazalete por lo menos hasta alcanzar una presi n 40 mmHg por encima de la presi n sist lica esperada Si desconoce este valor nflelo aproximadamente hasta un valor comprendido entre 160 180 mmHg La presi n del brazalete aparece continuamente en la pantalla Tras el proceso de inflado deje la perilla y permanezca sentado en posici n quieta y relajada La medici n sigue su curso Si no tiene lugar la medici n y s lo aparece en la pantalla una flecha parpadeante se a lando hacia arriba v ase m s adelante el apartado Cuando es necesario un mayor inflado En cuanto el aparato detencta el pulso el s mbolo del coraz n empieza a parpadear y emite un pip por cada latido del coraz n Cuando ha terminado la medici n suena un largo pip En la pantalla aparecen los valores de la presi n arterial sist lica diast lica y el pulso medidos La presi n del brazalete puede ser eliminada ahora r pidamente presionando la v lvula de escape de la perilla de la bomba de inflado 24 4 Operation of your blood pressure monitor 4 1 Inserting the batteries Afte
14. as s lo previa consulta con el m dico Interferencia electromagn tica El aparato contiene componentes electr nicos sensibles microordenador Por ello evite los campos el ctricos o electromagn ticos fuertes en la proximidad directa del aparato por ejemplo tel fonos m viles microondas pueden dar lugar a la p rdida temporal de la exactitud de medici n Tabla de contenido Introduccion 1 1 1 2 Caracteristicas del MDS2002 Informaci n importante sobre las automediciones Informaciones importantes sobre la tension arterial y su medicion 2A 2 2 2 3 C mo se origina la tensi n arterial alta baja Cu les son los valores normales Qu podemos hacer si se miden regularmente valores altos bajos Los diversos componentes del monitor de tensi n arterial Puesta en funcionamiento del monitor de tensi n arterial 4 1 4 2 Colocaci n de las pilas Conexi n del tubo Desarrollo de una medici n Jul 5 2 5 3 5 4 5 5 5 6 Dil Antes de la medici n Fuentes de error comunes Ajuste del brazalete Procedimiento de medici n Inflado adicional Interrupci n de la medici n Indicaci n del ltimo valor medido Memoria Mensajes de error funcionamiento defectuoso Cuidados y mantenimiento recalibraci n Garant a Est ndares de referencia 10 Especificaciones t cnicas 9 Certifications Device standard This medical device is manufac
15. atures of your blood pressure monitor Important information about self measurement Important information on blood pressure and its measurement 2 1 2 2 2 3 3 How does high low blood pressure arise Which values are normal What can be done if regular high low values are obtained Components of your blood pressure monitor 4 Operation of your blood pressure monitor 4 1 4 2 5 Inserting the batteries Tube connection Measurement procedure Dil 5 2 5 3 5 4 5 5 5 6 Di 6 Before measurement Common sources of error Fitting the cuff Measuring procedure No reading Inflating further Discontinuing a measurement Memory displaying the last measurement Error messages troubleshooting Care and maintenance Warranty Certifications 10 Technical specifications 9 Estandares de referencia Estandar del aparato El aparato cumple los requerimientos del est ndar europeo sobre instrumentos de control de la presi n arterial no invasivos EN1060 1 12 95 EN1060 3 09 97 DIN 58130 NIBP investigaci n cl nica ANSI AAMI SP10 NIBP requerimientos Compatibilidad electromagn tica El aparato cumple las especificaciones del est ndar europeo EN 60601 1 2 Ensayo cl nico El test de funcionamiento cl nico ha sido realizado en Alemania de acuerdo con el procedimiento DIN 58130 1997 N6 secuencial Cumple las especificac
16. ement is proceeding continue as described under points d e in section 5 4 5 6 Discontinuing a measurement If it is necessary to interrupt a blood pressure mea surement for any reason e g the patient feels unwell press the quick release valve at the pump ball The device then immediately lowers the cuff pressure automatically Quick Release for Cuff O 5 7 Memory displaying the last measurement I n With the unit in the OFF position Press and hold the 3 sec U L MEMORY button for at least 3 seconds The screen ra will go blank with the exception of the MR symbol ru in the lower left Release the button The last reading 71 will be displayed for approximately 5 seconds and Tm can be recalled again ts Further information Measurements should not occur soon after each other since the results will be inaccurate Wait for several minutes in a relaxed position sitting or lying before you repeat a measurement 10 6 Error messages troubleshooting If an error occurs during a measurement the measurement is ae discontinued and a corresponding error code is displayed Ll example error no 1 iy E f t Error No Possible cause s solutions ERR 1 The systolic pressure was determined The tube may have loos ened Or no pulse was detected Ensure cuff connections are tight with proper cuff placement See instruction booklet 5 3 ERR 2 The pressure dropped below 20
17. ent Ww efore using please read this instruction manual carefully and keep it in a safe place ease contact your doctor for further questions on the subject of blood pressure and its measurement me Attention 1 2 Important information about self measurement e Self measurement means Control not diagnosis or treatment Unusual values must always be dis cussed with your doctor Under no circumstances should you alter the dosages of any drugs prescribed by your doctor e The pulse display is not suitable for checking the frequency of heart pacemakers e In cases of irregular heartbeat Arrhythmia measurements made with this instrument should only be evaluated after consultation with your doctor Electromagnetic interference This device contains sensitive electronic components Avoid strong electrical or electromagnetic fields in the direct vicinity of the device e g mobile telephones microwave ovens These can lead to temporary impairment of the measuring accuracy 2 Important information on blood pressure and its measurement 2 1 How does high low blood pressure arise he level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of tuations through feedback from the nervous system 0 adjust blood pressure the strength and frequency of the heart Pulse as well as the width of circulatory ood vessels is altered The latter is effected by way of fine muscles in the blo
18. esults of your measurements to independently alter the drug doses prescribed by your doctor Which values are normal World Health Organization Range Systolic Blood pressure Diastolic Blood pressure Measures Hypotension low lower than 100 Lower than 60 Consult your doctor Normal range between 100 and 140 between 60 and 90 Monitor Regularly Mild hypertension high between 140 and 160 between 90 and 100 Consult your doctor Moderately serious hypertension Higher between 160 and 180 between 100 and 110 Consult your doctor urgent Serious hypertension very high higher than 140 higher than 110 Consult your doctor urgent Specific systolic hypertension higher than 140 Lower than 90 Consult your doctor Los resultados de cada medici n son distintos e Preste atenci n a la siguiente informaci n aunque el aparato funciona correctamente y los as como a los puntos enumerados en valores indicados son normales Fuentes de error comunes y repita la medici n Los valores medidos de la tensi n arterial difieren e Registre la evoluci n diaria de los valores de los medidos por el m dico y consulte a su m dico sobre los los mismos t Informaci n adicional El nivel de la tensi n arterial est sujeto a fluctuaciones incluso en las personas sanas Lo importante al respecto es que mediciones comparables requieren siempre las m
19. iones de la directiva de la UE 93 42 CEE para productos m dicos de la clase lla 29 Recalibraci n peri dica Los aparatos de medici n sensibles deben ser comprobados de vez en cuando respecto a su exactitud Por ello le recomendamos una inspecci n peri dica de la pantalla de presi n est tica cada 2 a os Su tienda especializada estar encantada de proporcionarle m s informaci n sobre el particular 8 Garant a El monitor de tensi n arterial MDS2002 tiene una garant a de 2 a os a partir de la fecha de compra Esta garant a incluye el instrumento El brazalete est garantizado por un a o a partir de la fecha de la compra La garant a no incluye los da os derivados de un manejo incorrecto accidentes la inobservancia de las instrucciones de uso o de las modificaciones efectuadas al instrumento por parte de terceros 28 1 Introduction 1 1 Features of your Medline upper arm semi automatic blood pressure monitor model MDS2002 This blood pressure monitor MDS2002 is a semi automatic digital blood pressure measuring device for use on the upper arm It enables very fast and reliable measurement of the systolic and diastolic blood pressure as well as the pulse by way of the oscillometric method This device offers clinically proven accuracy and has been designed to be user friendly oH he large display of MDS2002 allows both operational status and cuff pressure to be visible for the duration of the measurem
20. ismas condiciones condiciones de tranquilidad Si a pesar de observar todos estos factores las fluctuaciones son superiores a 15 mmHg y o escucha tonos de pulso irregulares en varias ocasiones consulte con su m dico El aparato ha sido objeto de ensayos cl nicos muy estrictos para su homologaci n en los que el programa de ordenador usado para medir los valores de la tensi n ha sido comprobado por experimentados m dicos especialistas en Alemania En cada aparato individual se usa el mismo programa de ordenador por lo que ha sido as comprobado cl nicamente El aparato se ha fabricado de acuerdo con las especificaciones del est ndar europeo para equipos de medici n de la presi n arterial vea Datos t cnicos bajo la supervisi n de la Asociaci n T cnica de Verificaci n RWT V Essen Consulte con su farmac utico o vendedor especializado si su tensi metro presenta problemas t cnicos No intente jam s arreglar el instrumento Ud mismo La abertura no autorizada del instrumento dejar sin efecto cualquier reclamaci n de garant a 7 Cuidados y mantenimiento recalibraci n a Evite exponer el tensi metro a temperaturas extremas a la humedad al polvo y a la irradiaci n de los rayos del sol b Evite las ca das tr telo con cuidado y no de golpes fuertes cD c Limpiar el aparato con un trapo suave y seco no utilizar detergentes ni disolventes d Evite plegar excesivamente el brazalete y el tub
21. lse measurement values e Repeated measurements without rest allows blood to accumulate in the arm This can lead to false re sults Measurements should be done after a 5 minute rest to ensure restoration of blood flow and accu rate measurements 5 3 Ajuste del brazalete a Pasar el extremo del brazalete con tope de goma integrado a trav s del arco met lico El cierre de Vel cro debe quedar mirando al exterior Si el brazalete ya est preparado s ltese este paso b Coloque el brazalete en la parte superior del brazo de manera que el tubo se ale la parte inferior del brazo c Col quese el brazalete tal como se muestra en el gr fico Aseg rese de que el l mite inferior del brazalete quede 2 3 cm por encima del codo y la salida del tubo de goma debe estar situada en la cara interna del brazo Importante La marca de longitud unos 3 cm del tubo debe quedar situada por encima de la arteria que recorre la cara interna del brazo d Tense el extremo libre del brazalete y ci rrelo con el Velcro e No debe quedar ning n espacio libre entre el brazo y el brazalete de lo contrario podr a influir en el resultado Quitese cualquier prenda de ropa que le apriete el brazo p ej un pullover f Cierre el brazalete con el Velcro de manera que quede ajustado confortablemente no demasiado apretado Extienda el brazo sobre la mesa con la palma de la mano hacia arriba de manera que el brazalete quede a la altur
22. o l e Cuando no se use el aparato durante mucho tiempo cambie las bater as f Quite las manchas del brazalete o la goma con un pa o h medo No lavar el brazalete g No abrir nunca el aparato si lo hace pierde la calibraci n hecha por el fabricante 6 Mensajes de error funcionamiento defectuoso Si se produce un error durante una medici n se inter rumpe la medici n y se visualiza el correspondiente c digo nr de error ejemplo error n 1 Error No Posible s causa s ERR 1 Se ha medido la presi n sist lica pero despu s la presi n del brazalete ha descendido por debajo de 20 mmHg Esto puede suceder cuando p ej el tubo se ha desconectado tras dicha medici n Otras posibles causas No se ha detectado el pulso ERR 2 La presi n descendi por debajo de 20 mmHg sin haberse realizado la medici n Se ha presionado la v lvula de escape durante la medici n ERR 3 El inflado del brazalete dura demasiado tiempo El brazalete est mal puesto o quiz la conexi n del tubo no garantice la capacidad herm tica ERR 5 Las lecturas medidas idican una diferencia inacept able entre las presiones sistolicas y diastolicas Tome otra lectura observando cuidadosamente las instrucciones Pongase en contacto con su medico si sigue obteniendo lecturas no usuales Otros posibles funcionamientos defectuosos y su soluci n Si aparecen problema
23. od vessel walls The level of arterial blood pressure changes periodically during heart activity During the blood ejection Systole the value is highest systolic blood pressure value At the end of the heart s rest period Dias tole pressure is lowest diastolic blood pressure value The blood pressure values must lie within certain normal ranges in order to prevent particular diseases o ou 2 2 Which values are normal Blood pressure is too high if at rest the diastolic pressure is above 90mmHg and or the systolic blood pressure is over 160mmbdg In this case please consult your doctor immediately Long term values at this level endanger your health due to continual damage to the blood vessels in your body Should the systolic blood pressure values lie between 140mmHg and 160mmHg and or the diastolic blood pressure values lie between 90mmHg and 95mmHg Consult your doctor Regular self checks will be neces sary With blood pressure values that are too low i e systolic values under 105mmHg and or diastolic values under 60mmHg consult your doctor Even with normal blood pressure values a regular self check with your blood pressure monitor is recom mended You can detect possible changes in your values early and react appropriately If you are undergoing medical treatment to control your blood pressure keep a record of values along with time of day and date Show these values to your doctor Never use the r
24. plazo el coraz n sufrir da os estructurales c Existen muchas causas diferentes para la aparici n de valores altos de la tensi n arterial Diferenciamos entre la hipertensi n primaria esencial y la hipertensi n secundaria El ltimo grupo puede ser adscrito a disfunciones org nicas espec ficas Consulte con su m dico para recibir informaci n sobre el posible origen de sus propios valores elevados de la tensi n arterial d Hay medidas que Ud puede tomar no nicamente para reducir una hipertensi n m dicamente diagnosticada sino tambi n como prevenci n Estas medidas forman parte de su forma de vida general A H bitos alimentarios Esfu rcese por mantener un peso normal que se corresponda con su edad Reduzca el sobrepe so e Evite el consumo excesivo de sal com n Evite comer grasas B Enfermedades anteriores e Siga fielmente cualquier instrucci n m dica para el tratamiento de posibles enfermedades an teriores tales como e diabetes Diabetes mellitus e trastornos en el metabolismo de las grasas e gota C H bitos Deje de fumar por completo Beba solo cantidades moderadas de alcohol Restrinja el consumo de cafe na caf 19 2 Informaciones importantes sobre la tension arterial y su medicion 2 1 C mo se origina la tensi n arterial alta baja El nivel de la tensi n arterial se determina en una parte del cerebro en el llamado centro circulatorio y se adapta a la situ
25. pressure instrument Never attempt to repair the instrument yourself as there are no user servicable parts inside and this will invalidate the warranty 1 Introduccion 1 1 Caracteristicas del MDS2002 El tensi metro digital BP MDS2002 es un aparato semi autom tico que permite medir la presi n arterial sist lica y diast lica y el pulso de forma r pida y fiable mediante un m todo de medici n oscilom trico El aparato ofrece una exactitud de medici n muy alta y cl nicamente comprobada y ha sido dise ado para proporcionar un m ximo de sencillez en su utilizaci n El tensi metro MDS2002 posee una gran pantalla LCD que permite visualizar el estado de funcionamiento y la presi n durante todo el proceso de medici n Antes de usarlo lea detenidamente este manual de instrucciones y luego gu rdelo en un lugar seguro Con tacte con su m dico si tiene m s preguntas sobre la tensi n arterial y su medici n Atenci n 1 2 Informaci n importante sobre las automediciones e No lo olvide automedici n significa control no diagn stico o tratamiento Los valores inusuales deben ser discutidos siempre con su m dico No modifique bajo ninguna circunstancia las dosis de cualquier medicamento que le haya recetado su m dico e El indicador de pulsaciones no es apropiado para medir la frecuencia de los marcapasos e En casos de irregularidad cardiaca arritmia las mediciones realizadas con este instrumento deben ser evaluad
26. r you have unpacked your device insert the batteries The battery compartment is located on the underside of the device see illustration Remove cover as illustrated w b Insert the batteries 4 x size AA 1 5 V following he indicated polarity c If the battery indicator appears in the display the batteries are discharged and the unit will not Low function Battery d If batteries are inserted incorrectly the display Indicator may function eratically or not at all Check battery po eX arity Attention e After the low battery indicator appears the device will not function until the batteries have been replaced e Please use AA Long Life or Alkaline 1 5 V Batteries Do not use rechargable batteries e Ifthe blood pressure monitor is left unused for long periods remove the batteries from the device Functional check y A Hold on the ON OFF button down to test all the display ZN elements When functioning correctly many icons will ap pear 4 2 Tube connection e Insert T connector on cuff tubing into cuff connec T connector tion opening on the left side of the monitor om 5 Measurement Procedure Please note You should always be seated before and during measurement 5 1 Before measurement e Avoid eating smoking as well as all forms of exertion directly before measurement These factors influ ence the measurement result Find time to relax
27. s esto es valores sist licos inferiores a 105 mmHg y o valores diast licos inferiores a 60 mmHg consulte igualmente con su m dico Incluso con valores normales de la tensi n arterial es recomendable efectuar de forma regular auto comprobaciones con su monitor para la tensi n arterial De esta forma Ud podr detectar a tiempo los posibles cambios en sus valores normales y reaccionar de forma apropiada Si Ud est siendo sometido a un tratamiento m dico para controlar su tensi n arterial mantenga un registro de los valores de su tensi n arterial efectuando automediciones de forma regular a determinadas horas del d a Muestre esos valores a su m dico No use nunca los resultados de sus comproba ciones para alterar por su cuenta las dosis de los medicamentos prescritas por su m dico Tabla de clasificaci n de los valores de tensi n arterial unidades mmHg Valores Tensi n arterial Tensi n arterial Medidas sist lica diast lica Hipotensi n inferior a 100 inferior a 60 compru bela con su m dico Valores normales entre 100 y 140 entre 60 y 90 autocomprobaci n L mite de hipertensi n entre 140 y 160 entre 90 y 100 compru bela con su m dico Hipertensi n media superior a 160 y 180 entre 100 y 110 consulte a su m dico Hipertensi n superior a 140 superior 100 consulte a su m dico moderadamente grave Hipertensi n grave superior a 140 superior a 90 consulte a su m dico 18 urgentemente
28. s al usar el aparato deben comprobarse los siguientes puntos y si es necesario deben tomarse las medidas correspondientes Funcionamiento defectuoso Remedio La pantalla permanece vac a al conectar el aparato a pesar de que las pilas est n colocadas 1 Compruebe que la polaridad de las pilas sea la correcta y si es necesario ins rtelas correctamente 2 Si la visualizaci n es inusual reinstale las pilas o sustit yalas La bomba funciona pero la presi n no aumenta e Compruebe la conexi n del tubo del brazalete y si es necesario con ctelo correctamente El aparato falla con frecuencia al medir la tensi n arterial o los valores medidos son demasiado bajos demasiado altos 26 1 Aj stese correctamente el brazalete 2 Aseg rese de que el brazalete no est demasiado apretado y de que no ha quedado arremangado presion ndole por encima de la zona correcta de medici n Qu tese las prendas de ropa que le aprieten 3 Realice de nuevo la medici n en un ambiente tranquilo cs Further information e f your values are mostly normal under resting conditions but exceptionally high under conditions of physical or psychological stress it is possible that you are suffering from so called labile hyperten sion Consult your doctor e Correctly measured diastolic blood pressure values above 120mmHg require immediate medical treatment 2 3 What can be done if regular increased low val
29. s que requieran fuerza Evite llegar al l mite de su capacidad En caso de haber sufrido enfermedades con anterioridad y o tener una edad superior a los 40 a os consulte con su m dico antes de comenzar a practicar deporte El le aconsejar sobre los tipos de deporte apropiados para Ud 3 Los diversos componentes del monitor de tensi n arterial La figura muestra el monitor de tensi n arterial MDS2002 que consta de a Unidad de medici n Pantalla de cristal l quido Bot n de encendido apa gado y de MEMORIA Conexi n del tubo del brazalete b Brazalete opcional Modelo MDS9872 para brazos de circunferencia 22 30 cm Modelo MDS9873 para brazos de circunferencia 30 38 cm disponible como accessorio especial 20 5 5 No Reading Inflating further f the cuff was not inflated sufficiently the measurement process is stopped after a few seconds and a flashing ar row pointing upwards appears in the display Cuff Pressure nflate again to at least 20 mmHg higher than the Too Low previous value The instruction to inflate further can appear several times if the pressure is still not sufficient Attention f the cuff is inflated too far over 300 mmHg a HI appears in the display and a warning signal is sounded The cuff pressure must then be immediately re Cuff Over leased using the quick release valve at the Inflated pump ball As soon as the cuff is inflated sufficiently and the mea sur
30. stantly The observed although the device functions normally and normal readings may accurately reflect your pressure values are displayed e Please read the information listed under common sources of error 5 2 Repeat the measurement Blood pressure values differ from e Pressure readings in your doctors office may be those measured by your doctor higher due to anxiety e Record the daily values and consult your doctor t Informacion adicional Si sus valores son pr cticamente normales en reposo pero excepcionalmente altos bajo estr s f sico o ps quico es posible que sufra de la llamada hipertensi n l bil Consulte con su m dico si tiene la sospecha de que ese puede ser su caso Un valor diast lico de la tensi n arterial medido correctamente que sea superior a 120 mmHg requiere tratamiento m dico inmediato 2 3 Qu podemos hacer si se miden regularmente valores altos bajos a Consulte con su m dico b Los valores altos de la tensi n arterial diversas formas de hipertensi n est n asociadas a medio y largo plazo con riesgos importantes para la salud Esto afecta a los vasos sangu neos de su cuerpo que est n en peligro debido a la constricci n causada por los dep sitos en las paredes de los vasos arterioesclerosis La consecuencia puede ser una deficiencia en el aporte de sangre a rganos importantes coraz n cerebro m sculos Es m s con valores altos de la tensi n arterial a largo
31. tured to meet the re quirements European and United States standards for non invasive blood pressure monitors EN1060 1 12 95 EN1060 3 09 97 DIN 58130 NIBP clinical investigation ANSI AAMI SP10 NIBP requirements Electromagnetic compatibility Device fulfils the stipulations of the European stan dard EN 60601 1 2 Clinical testing Clinical performance tests were carried out in the U S and Germany according to the DIN 58130 1997 procedure N6 sequential and AAMI U S The stipulations of the EU Guidelines 93 42 EWG for Medical Products Class lla have been fulfilled 10 Technical specifications Weight Size Storage temperature Humidity Operation temperature Display Measuring method Pressure sensor Measuring range SYS DIA Pulse Cuff pressure display range Memory Measuring resolution Accuracy Pressure Pulse Power source Accessories Technical alterations reserved cs Further information 265 g with batteries 131 W x 174 L x 73 H mm 5 to 50 C 23 F 122 F 15 to 85 relative humidity maximum 10 to 40 C 50 F 104 F LCD Display Liquid Crystal Display Oscillometric Capacitive 30 to 280 mmHg 40 to 200 beats per minute 0 299 mmHg Stores the last measurement 1 mmHg within 3 mmHg 5 of the reading 4 dry cells batteries UM 3 size AA 1 5 V cuff type MDS29872 for arm circumference 22 30 cm 8 11 15 11 13 16 cuff type
32. ues are obtained a Consult your doctor b Increased blood pressure values various forms of hypertension are associated with considerable health risks over time Arterial blood vessels in your body are endangered due to constriction caused by deposits in the vessel walls Arteriosclerosis A deficient supply of blood to important organs heart brain muscles can result Furthermore the heart will become structurally damaged with increased blood pressure values c There are many different causes of high blood pressure We differentiate between the common primary essential hypertension and secondary hypertension The latter group can be ascribed to specific organ malfunctions Please consult your doctor for information about the possible origins of your own in creased blood pressure values d There are measures which you can take to reduce and even prevent high blood pressure These mea sures must be permanent lifestyle changes A Eating habits e Strive for a normal weight corresponding to your age See your doctor for your ideal weight e Avoid excessive consumption of common salt e Avoid fatty foods Previous illnesses e Consistently follow all medical instructions for treating illness such as Diabetes Diabetes mellitus or sugar diabetes e Fat metabolism disorder e Gout C Habits e Give up smoking completely e Drink only moderate amounts of alcohol e Restrict your caffeine consumption Coffee tea chocolate
33. utton A short be be beep follows to indi cate that the instrument has adjusted to the surround ings and the measurement can begin A 0 is shown in the display b Connect the cuff to the device Plug the T connector in to the left hand side of the instrument c Grasp the pump ball with your free hand and Inflate the cuff to a pressure at least 20 40 mmHg higher than the expected systolic pressure If you do not know the value of this pressure inflate to a value of approximately 160 180 mmHg The cuff pressure is shown continuously on the display d After the inflation process lay down the pump ball and remain in a quiet and in a relaxed sitting posi tion The measurement now proceeds on its own If no measurement takes place and all that appears in the display is a flashing upwards pointing arrow you must begin again and pump higher When the instru ment detects a pulse a heart symbol in the display starts to flash and a beep is heard for every heart beat e When the measurement has been concluded a long beep tone sounds The measured systolic and diastolic blood pressure values as well as the pulse are now displayed The cuff pressure can now be quickly released by pressing the release valve at the pump ball You can quickly drop the cuff pressure at any time by pressing the release valve Before Pumping Finish Pumping Deflating Reading Complete Systolic Diastolic Pulse