Home

ELECTRONIC 7-DAY WATER HEATER TIME SWITCHES

image

Contents

1. Modelo EH40 240 V CA 50 60 Hz EH10 120 V CA 50 60 Hz Consumo de energ a EH10 1 0 W m x EH40 3 0 W m x Configuraci n de contactos EH10 SPST Modelo unipolar de una v a EH40 DPST Modelo bipolar de una v a Clasificaciones del interruptor por polo e 30 A inductivo resistivo 120 a 240 V CA 60 Hz e 1 H P 120 V CA 60 Hz e 1 1 2 H P 240 V CA 60 Hz e 5 A tungsteno 120 a 240 V CA 60 Hz Puntos de ajuste Eventos 12 en total 6 ENCENDIDO 6 APAGADO se puede asignar en cualquier combinaci n de d as de semana d as de fin de semana funcionamiento diario o semanal con lo que brinda hasta un m ximo de 84 operaciones semanales 42 ENCENDIDO 42 APAGADO Funcionamiento del reloj accionado por bater a 3 a os m nimo bater a alcalina industrial AA proporcionada con el interruptor temporizador Tiempo de ENCENDIDO APAGADO m nimo 1 minuto Tiempo de ENCENDIDO APAGADO m ximo 6 d as 23 horas 59 minutos Peso de env o 1 05 kg Caja Acero estirado 19 7 cm de alto 12 7 cm de ancho 7 6 cm de profundidad acabado gris con ranura para cerradura con resorte ventana de visualizaci n transparente y transferencia de mando externa Orificios ciegos Combinaci n de tama o de 1 2 a 3 4 uno en la parte posterior y a cada lado dos en la parte inferior Tama o del cable AWG n 10 INFORMACION GENERAL DE SEGURIDAD 1 Monte el interruptor temporizador en la ubicaci n deseada con los tres
2. 50 60 Hz EH10 120 V c a 50 60 Hz Consommation lectrique EH10 1 0 W max EH40 3 0 W max Configuration des contacts EH10 unipolaire unidirectionnel SPST EH40 bipolaire unidirectionnel DPST Caract ristiques des interrupteurs par p le e 30 A inductif resistif 120 240 V c a 60 Hz e 1 HP 120 V c a 60 Hz e 1 1 2 HP 240 V c a 60 Hz e 5 A tungst ne 120 240 V c a 60 Hz Points de consigne v nements 12 au total 6 ON 6 OFF Assignables dans toute combinaison aux jours de semaine jours de fin de semaine chaque jour ou une fois par semaine offrant jusqu a un maximum de 84 actions par semaine 42 ON 42 OFF Fonctionnement de l horloge sur piles 3 ans minimum pile alcaline AA de qualite industrielle fournie avec la minuterie Dur e ON OFF minimale 1 minute Dur e ON OFF maximale 6 jours 23 heures 59 minutes Poids d expedition 1 05 kg 2 37 Ib Boitier Acier tir hauteur 19 7 cm 7 3 4 po largeur 12 7 cm 5 po profondeur 7 6 cm 3 po finition grise avec fermoir a ressort verrouillable hublot transparent et commande manuelle externe Alv oles d foncables Combin es de 1 2 3 4 po une au dos et sur chaque c t deux au fond Calibre des fils N 10 AWG INFORMATIONS GENERALES DE SECURITE 1 Monter la minuterie a emplacement souhait par les trois trous de fixation pr vus a cet effet Monter la minuterie a hauteur des yeux si possible en pr voyant un e
3. Override active only when switch is set at RUN turns load ON if already off or OFF if already on Timer automatically resumes program cycle only when slide switch is in AUTO Note that this button is also accessible without opening the enclosure SPECIFICATIONS Clock Voltage Model EH40 240V A C 50 60 Hz EH10 120V A C 50 60 Hz Power Consumption EH10 1 0 W Max EH40 3 0 W Max Contact Configuration EH10 SPST Single pole single throw model EH40 DPST Double pole single throw model Switch Rating Per Pole e 30 amp inductive resistive 120 240V A C 60 Hz e 1 H P 120V A C 60 Hz e 1 1 2 H P 240V A C 60 Hz e 5 amp tungsten 120 240V A C 60 Hz Set Points Events 12 total 6 ON 6 OFF Can be assigned in any combination to weekdays weekend days daily or weekly operation providing up to a maximum of 84 weekly operations 42 ON 42 OFF Battery Powered Clock Operation 3 years minimum AA industrial grade alkaline supplied with time switch Minimum ON OFF Time 1 Minute Maximum ON OFF Time 6 days 23 hours 59 minutes Shipping Weight 2 37 Lbs 1 05 Kg Case Drawn steel 7 3 4 19 7 cm high 5 12 7 cm wide 3 7 6 cm deep gray finish with lockable spring hasp clear see through viewing window and external override Knockouts Combination of 1 2 3 4 one on back and each side two on bottom Wire Size AWG 10 GENERAL SAFETY INFORMATION 1 Mount the time
4. afuera para exponer la regleta de terminales 5 Quite 12 7 mm de aislamiento a los cables de alimentacion y carga NO USE CABLES DE ALUMINIO Inserte los extremos de los cables en las placas de terminal adecuadas y apriete los tornillos firmemente Use un cable AWG n 10 de cualquier tamano Conecte el cable a tierra en el terminal de conexi n a tierra en la parte inferior de la caja 6 Vuelva a colocar el aislamiento pl stico 7 Siga las instrucciones para la instalaci n de la bater a Aseg rese de que la bater a est funcionando adecuadamente Para esto revise que la pantalla est visible Si la pantalla tiene informaci n revuelta compruebe que la orientaci n de la polaridad de la bater a est como se muestra en la etiqueta de la cubierta luego presione el interruptor RESET Restablecimiento y mant ngalo presionado durante al menos dos segundos Tenga en cuenta que la bater a se puede reemplazar f cilmente sin retirar el mecanismo del interruptor temporizador o el cableado de campo Simplemente presione la cubierta de la bater a identificada con la palabra Battery Bater a hacia adentro y hacia abajo en la direcci n de la flecha Se recomienda que la bater a se reemplace con una bater a de celda alcalina industrial AA en intervalos de dos a tres a os como parte del mantenimiento normal del interruptor temporizador y que observe las marcas de polaridad de la bater a cuando la instale No se requiere
5. or groups of days of the week you wish an ON or OFF operation to occur Set Point Event ON OFF 240 LINE 1 NEUTRAL LINE 120 EH10 Fig 4 PROGRAMMING STEPS SET CURRENT DAY AND TIME Slide switch to TIME SET Push DAY until current day shows then push HOUR until current hour AM or PM shows Now push MINUTE until current minute shows Clock is now set Follow same procedure after replacing battery or changing time such as for daylight saving time SET YOUR PROGRAM Slide switch to PROG Display will look like this ePress DAY until desired program period shows see choices in PROGRAM PERIOD OPTIONS section above ePress HOUR until desired ON 1 hour shows that is the first time each day of the program period that you want the load to turn ON ePress MINUTE until desired minute shows ePress EVENT to program time for ON 1 and to advance to programming for OFF 1 ePress DAY again until all seven days of the week show or until another desired program period option shows see PROGRAM PERIOD OPTIONS e Press HOUR again until desired OFF 1 hour shows that is the first time each day of the program period that you want the devices to turn OFF ePress MINUTE until desired minute shows e Press EVENT to set time for OFF 1 You may now begin settingON2 asecondONtime forthe sameprogram period OR press DAY to change to a different program period eRepeat above procedure unt
6. presiona EVENT repetidamente se mostrar hasta el final del s mbolo de barra OFF 6 Sin embargo una vez que programe el temporizador cada ajuste de hora real que haga reemplazar al s mbolo de barra Mientras programa cada vez que presione EVENT avanzar al siguiente EVENTO OPCIONES DE PERIODO DE PROGRAMA El temporizador le da 6 ajustes diferentes de ENCENDIDO y de APAGADO por per odo de programa Puede usar todos los 6 ajustes por per odo o los que usted desee Un per odo de programa cubre uno de los siguientes e LOS 7 DIAS DE LA SEMANA combinados en uno la pantalla muestra MO TU WE TH FR SA SU LU MA MI JU VI SA DO e LUNES A VIERNES combinados en uno la pantalla muestra MO TU WE TH FR LU MA MI JU VI e SABADO Y DOMINGO combinados en uno la pantalla muestra SA SU SA DO e CADA DIA INDIVIDUAL DE LA SEMANA la pantalla solo muestra ese d a e EXPLICACI N DE D A EN BLANCO Aparece BLANKDAY D a en blanco despu s del domingo despu s de apretar el bot n DAY por ltima vez cuando el interruptor deslizante inferior est en PROG El fin del DIA EN BLANCO es desactivar un ajuste de programa en un d a Los per odos de programa con d as combinados en uno le permiten realizar ajustes para aquellos d as m ltiples de manera r pida y c moda mientras usa solo un par de ENCENDIDO APAGADO Cuando ajuste alg n per odo de programa como el anterior todos los ajustes ser n id nticos para cada
7. switch in the desired location using the three mounting holes which are provided Mount the time switch at eye level if possible providing sufficient room to the left of the enclosure for the cover to swing open fully See Fig 2 The time switch mechanism does not need to be removed from the enclosure to mount the time switch since the top mounting hole is a slotted type mounting hole Secure a screw or other fastener at eye level The head of the screw of fastener should be slightly larger than the narrow portion of the slotted hole to ensure that the time switch is securely held in place The remaining two mounting holes provide a means to secure the time switch 2 If you do remove the mechanism refer to Figure 3 and remove the mechanism from the case by depressing the catch at the top of the case and pulling out Mounting Holes Snap Out Catch Tilt Top Forward JE REE one N Ra a W a L 7 I anes Ll ot Ground Terminal Fig 2 Knockouts 3 Replace the mechanism in the case if it has been removed making sure to engage ribs at sides of mechanism between ears at sides of case before snapping in place 4 Lift the left side of the insulator off of the retaining post and pivot it up and away to expose the terminal Screws 5 Strip the supply and load wires by removing 1 2 inch of insulation DO NOT USE ALUMINUM WIRE Insert the wire ends under the proper terminal plates and tighten the screws firmly Us
8. tend l acheteur particulier initial uniquement et n est pas transf rable Cette garantie ne s applique pas a aux dommages au dispositif caus s par un accident une chute ou une mauvaise manipulation une catastrophe naturelle ou une utilisation n gligente b aux dispositifs soumis des r parations non autoris es qui ont t ouverts d mont s ou modifi s de quelconque mani re c aux dispositifs qui n ont pas t utilis s conform ment aux instructions d aux dommages d passant le co t du produit e aux lampes scell es et ou aux ampoules aux LED et aux piles f la finition de l une des parties du dispositif telle que la surface ou les caract ristiques de r sistance aux intemp ries ce qui est consid r comme de l usure normale g aux dommages caus s par le transport aux co ts d installation initiale aux co ts de d montage ou de remontage INTERMATIC INCORPORATED NE POURRA TRE TENUE RESPONSABLE DE DOMMAGES INDIRECTS OU CONS CUTIFS CERTAINES JURIDICTIONS N AUTORISENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES INDIRECTS OU CONS CUTIFS DANS CE CAS LES LIMITES CI DESSUS NE S APPLIQUENT PAS LA PR SENTE GARANTIE REMPLACE TOUTES LES AUTRES GARANTIES EXPRESSES OU IMPLICITES TOUTES LES GARANTIES IMPLICITES NOTAMMENT GARANTIE DE QUALIT MARCHANDE ET GARANTIE D ADAPTATION UNE FIN PARTICULI RE SONT MODIFI ES AUX PR SENTES POUR EXISTER UNIQUEMENT TELLES QUE COMPRISES DANS LA GARANTI
9. E LIMIT E ET AURONT LA M ME DUR E QUE LA P RIODE DE GARANTIE INDIQU E CI DESSUS CERTAINES JURIDICTIONS N AUTORISENT PAS LES LIMITES DE DUR E D UNE GARANTIE IMPLICITE DANS CE CAS LES LIMITES Cl DESSUS NE S APPLIQUENT PAS Le recours la pr sente garantie se fait soit a par renvoi du produit au vendeur aupr s duquel il a t achet soit b en remplissant le formulaire de r clamation sur le site Web www intermatic com La pr sente garantie est offerte par Intermatic Incorporated Customer Service 7777 Winn Rd Spring Grove Illinois 60081 9698 Pour recourir la garantie aller http www intermatic com ou composer le 815 675 7000 INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 60081 9698 TNTERMATIC INTERRUPTORES TEMPORIZADORES ELECTR NICOS DE 7 DIAS PARA CALENTADORES DE AGUA MODELOS EH10 120 V Y EH40 240 V CON TRASPASO DE BATERIA MAN PROG RUN ES AUTO NTERMATIC BATTERY WIN A Riesgo de incendio o descarga el ctrica e Desconecte la energ a desde los disyuntores o desde los interruptores antes de realizar la instalaci n o el mantenimiento e Es posible que requiera m s de un disyuntor o interruptor de desconexi n para desenergizar el equipo antes de realizar mantenimiento e La instalaci n o el cableado se deben realizar de acuerdo con los requisitos del C digo El ctrico Nacional y los requisitos locales e Use cables AWG n 10 SOLO conductores de COBRE e No toque l
10. EVENTS DAY CHECKS ON TIMES OFF TIMES DISPLAYED DAYS amp TIMES DISPLAYED EXAMPLE 1 MO TU WE TH FR SA SU 10 00 PM MO TU WE TH FR SA SU 5 00 PM EXAMPLE 2 MO TU WE TH FR 6 00 PM 10 00 PM MO TU WE TH FR 6 00 PM MO TU WE TH FR 10 00 PM SA SU 4 00 PM 8 00 PM SA SU 4 00 PM SA SU 8 00 PM EXAMPLE 3 MO TU WE TH FR MO TU WE TH FR 6 00 AM MO TU WE TH FR 9 30 AM MO TU WE TH FR 11 15 PM MO TU WE TH FR 5 30 PM MO TU WE TH FR 11 15 PM SA SU 10 00 PM SA SU 3 00 PM SA SU 10 00 PM EXAMPLE 4 MO TU WE TH 11 30 PM MO TU WE TH 8 00 PM MO TU WE TH 11 30 PM FR SA 2 20 PM SU 7 00 PM DAY AFTER SU 10 30 PM SU 10 30 PM FR 5 00 PM MO 11 30 PM SA 5 00 PM 11 30 PM BLANKDAY i 11 30 PM BLANKDAY i 11 30 PM bl 3 NOTE follows Sunday after last push of DAY button when the slide switch is set at PROG The purpose of the is to cancel a program setting on that day REVIEW YOUR PROGRAM Slide switch to PROG Press EVENT button to advance display to each ON or OFF setting Check days and times displayed To make a change follow instructions under SET YOUR PROGRAM To delete a displayed set point press DAY button until is displayed GENERAL FEATURES AND HINTS FOR TROUBLE FREE USE e BUTTON When you press a button there is an advance of one time unit holding a button down advances continuously until released e MAINTENANCE With the exception of battery replacement at 2 3 year intervals your Inter
11. FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b completing a warranty claim online at www intermatic com This warranty is made by Intermatic Incorporated Customer Service 7777 Winn Rd Spring Grove Illinois 60081 9698 For warranty service go to http www intermatic com or call 815 675 7000 INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 60081 9698 I NTERMATIC MINUTERIES LECTRONIQUES POUR CHAUFFE EAU 7 JOURS MODELES EH10 120 V ET EH40 240 V AVEC BASCULEMENT SUR PILES MAN PROG Eu EVENT DAY HOUR MIN BATTERY NTERMATIC PIN US AU Risque d incendie ou de choc lectrique e D brancher l alimentation au niveau des disjoncteurs ou des sectionneurs avant de proc der l installation ou l entretien e peut tre n cessaire d ouvrir plusieurs disjoncteurs ou sectionneurs pour mettre le mat riel hors tension avant d y travailler e L installation et ou le c blage doivent tre conformes aux exigences du code de l lectricit en vigueur e Utiliser des fils n 10 AWG Conducteurs en CUIVRE UNIQUEMENT e Ne pas touche
12. PM MO 11 30 PM TU JOUR BLANC JOUR BLANC TH 11 30 PM REMARQUE L affichage suit le dimanche SU lorsqu on appuie sur le bouton DAY avec le commutateur en position PROG L objet du jour blanc est d annuler un r glage de programmation pour ce jour PASSER LE PROGRAMME EN REVUE Mettre le commutateur en position PROG Appuyer sur le bouton EVENT pour faire d filer chaque r glage ON ou OFF V rifier les jours et heures affich s Pour effectuer une modification suivre les instructions de la section REGLER LE PROGRAMME Pour supprimer un point de consigne affich appuyer sur le bouton DAY jusqu a afficher FONCTIONNALITES GENERALES ET D UTILISATION e BOUTONS Lorsqu on appuie sur un bouton la valeur de temps affich e avance d une unite tenir le bouton enfonce pour avancer en continu jusqu ce qu il soit rel ch e ENTRETIEN A l exception du remplacement de la pile tous les 2 a3 ans la minuterie Intermatic est sans entretien e UNE FOIS L INSTALLATION TERMIN E LE FERMOIR VERROUILLABLE DOIT ETRE EN POSITION HAUTE POUR S ENGAGER SUR LE COUVERCLE LORSQUE CELUI CI EST FERME CONSEILS GARANTIE LIMITEE UN AN Si durant la p riode de garantie indiqu e ce produit pr sente un defaut de materiau ou de fabrication Intermatic Incorporated s engage a le r parer ou a le remplacer a sa seule discr tion sans frais La pr sente garantie s
13. RALES Y SUGERENCIAS PARA UN USO SIN PROBLEMAS e BOTON Cuando presione un bot n se produce un avance de una unidad de tiempo si lo mantiene presionado avanzar continuamente hasta que se suelte e MANTENIMIENTO Con la excepci n del reemplazo de la bater a en intervalos de 2 a 3 a os el temporizador Intermatic no necesita mantenimiento e DESPUES DE COMPLETAR LA INSTALACION LA RANURA PARA CERRADURA DEBE MOVERSE HACIA ARRIBA PARA ENGANCHAR LA CUBIERTA CUANDO ESTE CERRADA GARANT A LIMITADA DE UN A O Si dentro del per odo de garant a especificado este producto presenta fallas a causa de defectos en los materiales o en la mano de obra Intermatic Incorporated lo reparar o lo reemplazar a su exclusivo criterio sin cargo Esta garant a se extiende solo al comprador dom stico original y no es transferible Esta garant a no se aplica a a da o a las unidades causado por accidente ca da o manipulaci n indebida casos fortuitos o cualquier uso negligente b unidades que hayan sido reparadas abiertas desmontadas o modificadas de otra forma sin autorizaci n c unidades que no se hayan usado de acuerdo con las instrucciones d da os que excedan el costo del producto e focos o bombillas LED y bater as sellados f el acabado de cualquier parte del producto como la superficie o la alteraci n por exposici n a la intemperie puesto que se considera como desgaste natural g da o en el transporte costos de insta
14. TNTERMATIC ELECTRONIC 7 DAY WATER HEATER TIME SWITCHES MODELS EH10 120V AND EH40 240V WITH BATTERY CARRYOVER MAN PROG am TIME SET 1000 EVENT DAY HOUR MIN N TERMATIC BATTERY ne NS PUITS Risk of Fire or Electric Shock e Disconnect power at the circuit breaker s or disconnect switch es before installing or servicing e More than one circuit breaker or disconnect switch may be required to de energize the equipment before servicing e Installation and or wiring must be in accordance with National and Local Electrical Code requirements e Use 10 AWG wires COPPER conductors ONLY e Do not touch circuit board components contact can create a static discharge which can damage the microprocessor OWNER INSTALLER INSTRUCTION MANUAL RETAIN FOR FUTURE REFERENCE MANUAL MAN AUTOMATIC AUTO See Fig 1 e MANUAL Bypasses your program completely timer will not resume program until you return switch to AUTO mode position e AUTOMATIC For automatically switching at ON OFF times accurate to the minute PROGRAM PROG RUN TIME SET e PROGRAM Use this position when programming e RUN Use this position for normal operation Be sure to return to RUN after setting time and program e TIME SET Use this position to set day and time of day ON OFF EVENT the large push button Serves a dual purpose e EVENT Used for programming active only when switch is set at PROG e ON OFF
15. d a de dicho per odo EJEMPLOS DE PROGRAMAS PERSONALES EVENTOS HORAS DE HORAS DE D AS Y HORAS QUE SE D AS SELECCIONADOS ENCENDIDO APAGADO SE MUESTRA MUESTRAN EJEMPLO 1 MO TU WE TH FR SA SU 10 00 PM MO TU WE TH FR SA SU 5 00 PM EJEMPLO 2 MO TU WE TH FR 6 00 PM 10 00 PM ON 1 MO TU WE TH FR 6 00 PM OFF 1 MO TU WE TH FR 10 00 PM SA SU 4 00 PM 8 00 PM ON 2 SA SU 4 00 PM OFF 2 SA SU 8 00 PM EJEMPLO 3 MO TU WE TH FR MO TU WE TH FR 6 00 AM MO TU WE TH FR 9 30 AM MO TU WE TH FR 5 30 PM MO TU WE TH FR 11 15 PM SA SU 10 00 PM SA SU 3 00 PM SA SU 10 00 PM MO TU WE TH FR EJEMPLO 4 MO TU WE TH 11 30 PM MO TU WE TH 8 00 PM MO TU WE TH 11 30 PM FR SA 2 20 PM E SU 7 00 PM DIA DESPUES SU 10 30 PM SU FR 5 00 PM MO 11 30 PM SA 5 00 PM TU 11 30 PM BLANKDAY WE 11 30 PM BLANKDAY TH 11 30 PM NOTA aparece despu s del domingo despu s de apretar el bot n DAY por ltima vez cuando el interruptor deslizante est en PROG El prop sito de es cancelar un ajuste de programa en tal d a REVISE SU PROGRAMA Deslice el interruptor a PROG Presione el bot n EVENT para avanzar en la pantalla a cada ajuste de ENCENDIDO o APAGADO Revise los d as y las horas que se muestran Para realizar un cambio siga las instrucciones en AJUSTE SU PROGRAMA Para borrar un punto de ajuste que se muestra presione el bot n DAY hasta que se muestre Co CARACTER STICAS GENE
16. e any size wire AWG 10 Connect ground wire to grounding terminal at bottom of case 6 Replace the plastic insulator 7 Follow instructions for battery installation Be sure that the battery is functioning properly This can be checked by seeing that the display is visible If the display has scrambled information check to be sure that the polarity orientation of the battery is as shown on the cover label then press the RESET switch and hold for at least two seconds Note that the battery can easily be replaced without removing the time switch mechanism or field wiring Simply press in and downward in the direction of the arrow on the battery cover which is identified with the word Battery It is recommended that the battery be replaced with a AA industrial grade alkaline cell at two to three year intervals as part of the normal time switch maintenance observing battery polarity markings when installing No other maintenance is required 8 Place the slide switches in the AUTO and RUN position 9 Reapply power to the time switch 10 Press the recessed reset switch for at least two seconds The display will show 12 00 A M and MO Note that the days of the week are identified with the first two letters of the day MO for Monday The timer is now ready for programming Refer to the examples which follow and enter the scheduled events set points required Assign each of the 12 set points EVENTS entered to whichever day
17. ig 5 CAUTION Do not use jumpers if load s are not 120 or 240 VAC because the load can be damaged Supply separate power of the correct voltage REMARQUE II ise possible d introduire des cavaliers pour alimenter la charge Pour les charges de 120V voir Fig 4 Pour Les charges de 240 V voir Fig 5 AVERTISSEMENT Ne pas utiliser de cavaliers si la ou les charges ne sont pas de 120 ou 240V car la chare PEUT s en trouver endommage Fournir une limentation separee sous tension correcte NOTA Los puentes de conexion pueden anadirse para suministrar alimentacion a la carga Para cargas de 120V ver Fig 4 Para Cargas de 240 V ver Fig 5 ATENCION No utilice los puentes de conexi n si la s carga s no son de 120 o 240V porque la carga puede danarse Suministrar alimentacion por separado con la tension adecuada ALIMENTATION Trous de montage MINUTERIE Agujeros para montar ALIMENTACION DEL TEMPORIZADOR NEUTRE LIGNE NEUTRAL LINEA Pour interrompre un cot d une charge de 120 V Para cortar un lado de una CHARGE carga de 120 voltios LIGNE CARGA NOTA S lo para cargas de 120 LINEA voltios yo que la tension del tempo rizador ees de 120 VCA los puentes de conexi n pueden a adirse entr las terminales 2 y 3 para suminis cis trar alimentaci n a la carga NEUTRE Mise a la terre h ATENCION No utilice los puentes NEUTRAL Terminal a tierra Agujeros Ciegos de conexi n si la s carga s no son de 120 voltios por
18. il all desired ON OFF programs are set PLEASE NOTE Before you program your timer or when you remove the battery or when you use the RESET pressing EVENT will display the bar symbol ON 1 Repeated pressing of EVENT will display all the way through the final bar symbol OFF 6 Once you program your timer however each actual time setting you make will replace the bar symbol While programming each time you press EVENT you will advance to the next EVENT PROGRAM PERIOD OPTIONS Your timer gives you up to 6 different ON and 6 different OFF settings per program period You can use all 6 settings per period or as few as you like A program period covers one of these e ALL 7 DAYS OF THE WEEK combined into one display shows MO TU WE TH FR SA SU eMONDAY THRU FRIDAY combined into one display shows MO TU WE TH FR e SATURDAY AND SUNDAY combined into one display shows SA SU e EACH INDIVIDUAL DAY OF THE WEEK display shows only that day e BLANKDAY EXPLANATION BLANKDAY follows Sunday after last push of DAY button when the lower slide switch is set at PROGRAM The purpose of the BLANKDAY is to disable a program setting on a day Program periods with days combined into one help you make settings for those multiple days quickly and conveniently while using only one ON OFF pair When you set such a program period all settings will be identical for every day of that period PERSONAL PROGRAM EXAMPLES
19. ion de OFF 1 e Appuyer de nouveau sur DAY jusqu afficher les sept jours de la semaine ou une autre p riode de programmation souhait e voir CHOIX DE P RIODES DE PROGRAMMATION e Appuyer de nouveau sur HOUR jusqu afficher l heure OFF 1 souhait e c d l heure de la premi re mise hors tension du circuit de charge chaque jour de la p riode de programmation e Appuyer sur MINUTE jusqu afficher les minutes souhait es e Appuyer sur EVENT pour valider l heure OFF 1 pr sent une deuxi me heure de mise sous tension ON 2 peut tre programm e SOIT pour la m me p riode de programmation SOIT pour une p riode de programmation diff rente choisie en appuyant sur DAY e R p ter la proc dure ci dessus jusqu ce que tous les evenements ON OFF souhait s soient programmes REMARQUE Avant la programmation de la minuterie ou lorsque la pile est retir e ou encore apr s utilisation du bouton RESET lorsqu on appuie sur EVENT l cran affiche ON 1 Une pression r p t e sur le bouton EVENT fait d filer l affichage jusqu OFF 6 Une fois que la minuterie est programmee les reglages d heure s affichent a la place des tirets Durant la programmation chaque fois qu on appuie sur EVENT la minuterie passe l v nement suivant CHOIX DE PERIODES DE PROGRAMMATION La minuterie offre jusqu 6 r glages ON et 6 r glages OFF diff rents par p riode de programmation Il est
20. laci n inicial costos de retiro o costos de reinstalaci n INTERMATIC INCORPORATED NO SER RESPONSABLE DE DA OS INCIDENTALES O INDIRECTOS ALGUNOS ESTADOS NO PERMITEN LA EXCLUSI N O LIMITACI N DE DA OS INCIDENTALES O INDIRECTOS DE MODO QUE LA LIMITACI N O EXCLUSI N ANTERIOR PODR A NO APLICARSE A SU CASO ESTA GARANT A REEMPLAZA TODAS LAS DEM S GARANT AS EXPRESAS 0 IMPL CITAS TODAS LAS GARANT AS IMPL CITAS INCLUIDA LA GARANT A DE COMERCIABILIDAD Y LA GARANT A DE IDONEIDAD DEL PRODUCTO PARA UN PROP SITO EN PARTICULAR POR MEDIO DEL PRESENTE QUEDAN MODIFICADAS PARA TENER VALIDEZ SOLO COMO SE INDICA EN ESTA GARANT A LIMITADA Y TENDR N LA MISMA DURACI N QUE EL PER ODO DE GARANT A ESTIPULADO ANTERIORMENTE ALGUNOS ESTADOS NO PERMITEN LIMITACIONES A LA DURACI N DE UNA GARANT A IMPL CITA DE MODO QUE LA LIMITACI N ANTERIOR PODR A NO APLICARSE A SU CASO Este servicio de garant a est disponible ya sea a si se devuelve el producto al proveedor donde se compr la unidad o b si se completa una reclamaci n de garant a en l nea en www intermatic com Esta garant a la otorga Intermatic Incorporated Customer Service 7777 Winn Rd Spring Grove Illinois 60081 9698 Para obtener servicios de garant a ingrese a http www Intermatic com o llame al 815 675 7000 INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 60081 9698 NOTE Jumpers can be added to supply load power for 120 V loads see Fig 4 For 240 V loads See F
21. mantenimiento adicional 8 Coloque los interruptores deslizantes en la posici n AUTO y RUN 9 Vuelva a aplicar energ a al interruptor temporizador 10 Presione el interruptor de restablecimiento empotrado durante al menos dos segundos La pantalla mostrar 12 00 A M y MO Tenga en cuenta que los d as de la semana se identifican con las primeras dos letras del dia en ingl s MO para lunes Monday El temporizador est listo para la programaci n Consulte los ejemplos a continuaci n e ingrese los eventos programados puntos de ajuste necesarios Asigne cada uno de los 12 puntos de ajuste EVENTOS ingresados a cualquier d a o grupo de d as de la semana en los que desea que ocurra una operaci n de ENCENDIDO o APAGADO Punto de ajuste Evento ENCENDIDO APAGADO ENERG A DEL ENERG A DEL TEMPORIZADOR TEMPORIZADOR NEUTRO L NEA 120 EH10 Fig 4 NEUTRO PASOS PARA PROGRAMAR AJUSTE EL DIA Y LA HORA ACTUALES Deslice el interruptor a TIME SET Presione DAY D a hasta que se muestre el d a actual luego presione HOUR Hora hasta que se muestre la hora actual a m o p m Ahora presione MINUTE Minuto hasta que se muestren los minutos actuales Ahora el reloj est ajustado Siga el mismo procedimiento despu s de reemplazar la bater a o cambiar la hora por ejemplo para el horario de verano AJUSTE SU PROGRAMA Deslice el interruptor a PROG La pantalla se ver as e Presione DAY hasta que se
22. matic timer is maintenance free e AFTER THE INSTALLATION IS COMPLETED THE LOCKABLE HASP SHOULD BE MOVED TO THE UP POSITION TO ENGAGE THE COVER WHEN IT IS CLOSED LIMITED ONE YEAR WARRANTY If within the warranty period specified this product fails due to a defect in material or workmanship Intermatic Incorporated will repair or replace it at its sole option free of charge This warranty is extended to the original household purchaser only and is not transferable This warranty does not apply to a damage to units caused by accident dropping or abuse in handling acts of God or any negligent use b units which have been subject to unauthorized repair opened taken apart or otherwise modified c units not used in accordance with instructions d damages exceeding the cost of the product e sealed lamps and or lamp bulbs LED s and batteries f the finish on any portion of the product such as surface and or weathering as this is considered normal wear and tear g transit damage initial installation costs removal costs or reinstallation costs INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES ALL IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF
23. muestre el per odo de programa deseado consulte las opciones en la secci n OPCIONES DEL PERIODO DE PROGRAMACION mencionada posteriormente e Presione HOUR hasta que se muestre la hora ON 1 Encendido 1 deseada es decir la primera vez de cada d a del per odo del programa que quiere que se ENCIENDA la carga e Presione MINUTE hasta que se muestre el minuto deseado e Presione EVENT Evento para programar la hora del ON 1 y para avanzar hacia la programaci n del OFF 1 Apagado 1 e Presione DAY nuevamente hasta que se muestren todos los d as de la semana o hasta que se muestre otra opci n de per odo de programa deseado consulte OPCIONES DE PERIODO DE PROGRAMA e Presione HOUR nuevamente hasta que se muestre la hora OFF 1 deseada es decir la primera vez de cada d a del per odo del programa donde quiere que se APAGUEN los dispositivos e Presione MINUTE hasta que se muestre el minuto deseado e Presione EVENT para ajustar la hora de OFF 1 Ahora puede comenzar el ajuste de ON 2 una segunda hora de ENCENDIDO para el mismo per odo de programa O BIEN presione DAY para cambiar a un per odo de programa diferente e Repita el procedimiento anterior hasta que se ajusten todos los programas de ENCENDIDO APAGADO deseados TENGA EN CUENTA Antes de programar el temporizador cuando retire la bater a o bien cuando use el RESTABLECIMIENTO si presiona EVENT mostrar el s mbolo de barra ON 1 Si
24. orificios de montaje que se proporcionan Monte el interruptor temporizador al nivel de sus ojos si es posible y proporcione suficiente espacio hacia la izquierda de la caja para que la cubierta se abra completamente Consulte Fig 2 No es necesario retirar el mecanismo del interruptor temporizador de la caja para montarlo ya que el orificio de montaje superior es un orificio de montaje de tipo ovalado Fije un tornillo u otro sujetador al nivel de los ojos La cabeza del tornillo o el sujetador debe ser levemente m s grande que la parte angosta del orificio ovalado para garantizar que el interruptor temporizador quede bien sujeto Los dos orificios de montaje restantes brindan la posibilidad de fijar el interruptor temporizador 2 Si desea retirar el mecanismo consulte Figura 3 presione el ret n en la parte superior de la caja y tire del mecanismo hacia afuera para retirarlo Orificios de montaje ae Ret n de desencaje Superior hacia a presi n adelante ems Rs a one N No para retirar J miei HE i A s Moi Terminal de elle conexion a tierra Fig 2 Orificios ciegos 3 Vuelva a colocar el mecanismo en la caja si lo ha retirado y asegurese de enganchar las ranuras de los costados del mecanismo entre los bordes ondulados de los costados de la caja antes de encajarlo en su lugar 4 Levante el lado izquierdo del aislamiento para sacarlo del borne de retencion y girelo hacia arriba y hacia
25. os componentes del tablero de circuitos el contacto puede provocar una descarga est tica lo que puede da ar el microprocesador MANUAL DE INSTRUCCIONES PARA EL PROPIETARIO O INSTALADOR CONSERVE PARA CONSULTA FUTURA MAN MANUAL AUTO AUTOM TICO Consulte la Fig 1 e MAN Omite el programa completamente el temporizador no continuar con el programa hasta que vuelva a colocar el interruptor en la posici n del modo AUTOMATICO e AUTO Para realizar conmutaci n autom tica en las horas de ENCENDIDO y APAGADO con precisi n PROG PROGRAMA RUN EJECUCI N TIME SET AJUSTE DE HORA e PROG Use esta posici n cuando realice la programaci n e RUN Use esta posici n para el funcionamiento normal Aseg rese de volver a RUN despu s de ajustar la hora y el programa e TIME SET Use esta posici n para ajustar la fecha y la hora del d a ON OFF EVENT Encendido apagado Evento El bot n pulsador grande sirve para un prop sito doble e EVENT Se usa para programar solo activo cuando el interruptor se ajusta en PROG e ON OFF Transferencia de mando activo solo cuando el interruptor se ajusta en RUN ENCIENDE la carga si ya est apagada o la APAGA si ya est encendida El temporizador autom ticamente contin a con el ciclo de programa solo cuando el interruptor deslizante est en AUTO Tenga presente que tambi n se puede acceder a este bot n sin abrir la caja ESPECIFICACIONES Voltaje del reloj
26. possible d utiliser les 6 r glages ou moins dans une m me p riode Les p riodes de programmation possibles sont les suivantes e LES 7 JOURS DE LA SEMAINE combin s l cran affiche MO TU WE TH FR SA SU e DU LUNDI AU VENDREDI combin s l cran affiche MO TU WE TH FR e SAMEDI ET DIMANCHE combin s l cran affiche SA SU e UN JOUR INDIVIDUEL DE LA SEMAINE l cran affiche uniquement le jour consid r e FONCTION DE JOUR BLANC Un JOUR BLANC suit le dimanche SU lorsqu on appuie sur le bouton DAY avec le commutateur en position PROG L objet du jour blanc est de d sactiver la programmation durant un jour Les p riodes de programmation ayant des jours combin s permettent une programmation rapide et pratique sur de multiples jours tout en n utilisant qu une seule paire ON OFF Lorsqu une telle p riode de programmation est choisie tous les r glages sont identiques pour chaque jour de cette p riode EXEMPLES DE PROGRAMMATION JOURS CHOISIS HEURES ON AFFICHAGE AFFICH S EXEMPLE 1 MO TU WE TH FR SA SU 10 00 PM MO TU WE TH FR SA SU 5 00 PM EXEMPLE 2 MO TU WE TH FR MO TU WE TH FR 6 00 PM MO TU WE TH FR 10 00 PM SA SU SA SU 4 00 PM EXEMPLE 3 MO TU WE TH FR MO TU WE TH FR MO TU WE TH FR 11 15 PM SA SU SA SU 3 00 PM SA SU 10 00 PM EXEMPLE 4 MO TU WE TH MO TU WE TH 8 00 PM MO TU WE TH 11 30 PM FR SA 2 20 PM SU 7 00 PM LENDEMAIN SU 10 30 PM SU 10 30 PM FR 5 00
27. que la carga puede danarse Suministrar alimentaci n por sepa Fig 2 rado con la tensi n adecuada ALIMENTATION MINUTTERIE ALIMENTACION DEL TEMPORIZADOR Install jumper only if timer input and load voltage are the same AS S Sc wre and thd ed wire with stranded 1 3 Y 6 z wire 4 Utiliser fil massif avec nn fil massif et fil toronne avec fil toronn Ne pas m langer LIGNE 2 Utilice cable solido LINEA 2 con cable solido y cable trenzado con cable trenzado no los combine Pour interrompre les deux CHARGE c t s d une charge de 240 V CARGA Para cortar un lado de una Fig 5 Pen carga de 240 voltios INTERMATIC INCORPORATED SPRING GROVE ILLINOIS 60081 9698 8 158 01586
28. r les composants du circuit imprim le contact peut provoquer une d charge d lectricit statique susceptible d endommager le microprocesseur MANUEL D INSTRUCTION DE L UTILISATEUR INSTALLATEUR A CONSERVER POUR REFERENCE ULTERIEURE MANUEL MAN AUTOMATIQUE AUTO Voir Fig 1 e MANUEL Ignore compl tement le programme la minuterie ne reprend le programme que lorsque le commutateur est remis en position AUTO e AUTOMATIQUE Commutation automatique aux temps ON OFF programmes pr cis a la minute pres PROGRAMME PROG RUN TIME SET e PROGRAMME Utiliser cette position pour la programmation e RUN Utiliser cette position pour la marche normale Veiller a bien revenir en position RUN apr s le r glage de l heure ou la programmation e TIME SET Utiliser cette position pour r gler le jour et l heure de la journ e ON OFF EVENT le grand bouton poussoir Remplit deux fonctions e EVENT Utilis pour la programmation actif uniquement si le commutateur est en position PROG e ON OFF Priorite manuelle active uniquement si le commutateur est en position RUN met le circuit sous tension ON s il est coup ou hors tension OFF s il est en marche La minuterie reprend automatiquement le cycle programme uniquement si le s lecteur est en position AUTO On notera que ce bouton est accessible sans ouvrir le boitier DONNEES TECHNIQUES Tension de l horloge Mod le EH40 240 V c a
29. rammation En se r f rant aux exemples qui suivent entrer les v nements programm s points de consigne souhait s Assigner chacun des 12 points de consigne v nements entr s au jour ou groupe de jours de la semaine auxquels un action ON ou OFF doit se produire Point de consigne Ev nement ON OFF ALIMENTATION ALIMENTATION MINUTERIE MINUTERIE NEUTRE PHASE 120 EH10 Fig 4 PROGRAMMATION REGLER LE JOUR ET L HEURE COURANTS Mettre le commutateur en position TIME SET Appuyer sur DAY jusqu afficher le jour courant puis sur HOUR jusqu afficher l heure courante y compris AM ou PM Appuyer ensuite sur MINUTE jusqu afficher les minutes courantes L horloge est a pr sent r gl e Suivre la m me proc dure apr s avoir chang la pile ou pour changer l heure passage l heure d t par _ exemple REGLER LE PROGRAMME Mettre le commutateur en position PROG L affiche a l aspect suivant Ta e Appuyer sur DAY jusqu afficher la p riode de programmation souhait e voir les choix dans la section CHOIX DE P RIODES DE PROGRAMMATION e Appuyer sur HOUR jusqu afficher l heure ON 1 souhait e c d l heure de la premi re mise sous tension du circuit de charge chaque jour de la p riode de programmation e Appuyer sur MINUTE jusqu afficher les minutes souhait es e Appuyer sur EVENT pour valider l heure de programmation de ON 1 et passer la programmat
30. space suffisant sur la gauche du bo tier pour ouvrir compl tement le couvercle voir Fig 2 Il n est pas n cessaire de d monter le m canisme de minuterie du boitier pour permettre la pose dans la mesure ou le trou de fixation du haut est de type trou en poire Poser une vis ou autre attache de fixation a hauteur des yeux La t te de la vis ou de l attache doit tre l g rement plus grande que la partie troite du trou en poire afin d assurer que la minuterie soit solidement tenue en place Les deux trous de fixation restants servent a fixer la minuterie en place 2 Le cas ch ant le m canisme peut tre demonte en appuyant sur le taquet en haut du boitier et en tirant le m canisme hors du boitier voir Fig 3 D gager le Incliner le haut taquet vers lavant Trous de fixation De Le Ci N E q owes O iS ee Borne de terre r Alv oles Fi g 2 d fon ables 3 Remettre le m canisme en place dans le bo tier s il a t d mont en veillant bien engager les nervures sur les c t s du m canisme entre les pattes sur les c t s du bo tier avant de l encliqueter en place 4 Detacher le c t gauche du couvre bornes de la barrette de retenue et le faire pivoter pour exposer les vis du bornier 5 Denuder les fils d alimentation et de charge sur 13 mm 1 2 po NE PAS UTILISER DE FIL D ALUMINIUM Enfiler le bout des fils sous la plaquette de contact des bornes correspondan
31. tes et serrer fermement les vis Utiliser tout calibre de fil n 10 AWG Raccorder le fil de terre a la borne de terre au bas du boitier 6 Remettre le couvre bornes en plastique en place 7 Suivre les instructions de mise en place de la pile S assurer que la pile fonctionne correctement Pour cela v rifier que l affichage est visible Si cran pr sente un affichage brouill v rifier que la pile est orient e conform ment la polarit indiqu e sur le couvercle puis tenir le bouton RESET enfonc pendant au moins deux secondes On notera que la pile est facile changer sans d monter le m canisme de minuterie ni le c blage Il suffit d appuyer sur le couvercle de pile marqu Battery et de le pousser vers le bas dans le sens de la fl che Il est recommand de remplacer la pile par une pile alcaline AA de qualit industrielle tous les deux ou trois ans dans le cadre de l entretien normal de la minuterie en respectant les marquages de polarit lors de la mise en place de la pile Aucun autre entretien n est n cessaire 8 Placer les selecteurs en position AUTO et RUN 9 Remettre la minuterie sous tension 10 Appuyer sur l interrupteur encastr RESET pendant au moins deux secondes L cran affiche alors 12 00 A M et MO On notera que les jours de la semaine sont identifi s par les deux premi res lettres de leur nom en anglais MO pour lundi Monday La minuterie est a pr sent pr te pour la prog