1. R Kar EPA BLS MOD KSJ2 0L 1 MANUAL DE INSTRUCCIONES Indice 1 ESPEEMIGAGIOMES oe oc Sec ede wade estate eeki 3 2 Componentes ics as reeet tp os te le tas SIRE Se oe eee edn 3 li ONC OME ne Eede iede derne rete tea ee 3 4 C mo funciona o 3 5 C mo usar el humidificador eenen 4 6 Limpieza y Mantenimiento 2222 22 ceesecctceecececscccecsecsccsccs keela 4 AA A ates eases 5 8 Sabe usted qu lee eesse eelsed eee 5 A A snee dees 5 10 Posibles problemas y soluciones eenen sereen 7 CASTELLANO 1 Especificaciones Voltaje 220 240V 50Hz Potencia 35W Capacidad del dep sito 2 0L Nebulizaci n maxima 400 ml h 2 Componentes Asa Tapa del agua Salida nebulizaci n Dep sito de agua Ventilador Luz de posici n Nivel de agua Transductor Base On off Detector del nivel del agua Control intensidad nebulizacion 3 Introduccion EI humidificador EPA PLUS esta fabricado con plastico reciclable Puede funcionar de forma continuada de 5h a 10h seg n se desee ajustar la nebu lizaci n Aporta una humedad suave refrescando el ambiente de la estancia Es silen cioso y esta protegido por un sistema de auto desconexi n que permite ahorrar energia y a su vez proteger la durabilidad de sus principales componentes 4 C mo funciona La nebulizaci n se realiza mediante la generaci n de ondas ultras nicas El humidifica dor est provisto de un transductor que genera est
2. 08011 Spain C Trabajos peri dicos de control mantenimiento y reparaci n D El mal funcionamiento o la fatiga de accesorios u otros suplementos exceptuando el mismo aparato si no figuran expl citamente en el texto superior como sujetos a garant a E Los costes provenientes de reclamaciones injustificadas de garant a Tales costes ser n fac turados F Los costes ocasionados por accidentes o por el uso indebido del aparato y los da os persona les resultantes G Las reparaciones o sustituciones llevadas a cabo durante el tiempo de garant a no prolongan o renuevan la duraci n de la misma nicamente se puede hacer prevalecer el derecho de garant a si se devuelve el producto completo con todos sus accesorios acompa ados de la tarjeta de ga rant a debidamente cumplimentada tal come se indica a continuaci n y la factura original ticket de caja entregada al cliente en el establecimiento de compra Per xidos Farmac uticos S A se reserva el derecho de rehusar el derecho de garant a si las informaciones indicadas no son todas suficientemente claras Representante UE Laboratorios Vitrotec C De Art n 50 08041 Barcelona Spain ENGLISH Index 1 Specifications cc 10 2 COMPONER ct TO ka 10 de General HARI AEGA cruz ct a ios ati 10 4 How it works 222 2o a00 000 LLL 10 5 How to use 88 0002022022022222 11 6 Cleaning and maintenace __ L eenen eenn 11 DOO MONE G eas cle A oss eens 12 8 Do you know een
3. dep sito lleno de agua m s de 2 d as para evitar los malos olores Si no utiliza el humidificador de forma continuada debe ser vaciado el dep sito y guardar limpio y vac o Se recomienda el cambio de agua frecuentemente B Transductor Debido a factores geogr ficos la calidad del agua puede variar en diferentes zonas En algunos lugares la dureza del agua es muy alta debido al alto contenido de mi nerales y calcio Adem s el uso de la cloraci n de agua incrementa la dureza del agua en esas zonas En estos casos al humidificar el aire los iones de cal y magnesio se difunden con la nebulizaci n Con el tiempo puede crear sedimentos en la base y en el transductor llegando a afectar al funcionamiento del humidificador Por ello son importantes las siguientes recomendaciones para su limpieza a A ada unas gotas 0 5g de alg n limpiador cualquier limpiador anti cal que en cuentre en el mercado ser a v lido Ponga esa cantidad en el transductor con algo CASTELLANO de agua y espere de 2 a 5 minutos b Use un cepillito suave para limpiar la superficie o cubeta de la base y el trans ductor No utilice ning n instrumento punzante ya que podr a rayar la superficie del transductor o base c No utilice jab n o sustancias alcalinas para limpiar el transductor C Base a Sien la cubeta de la base y en el detector del nivel de agua hubiesen restos de cal use un limpiador anti cal para eliminar los sedimentos y
4. The original package is the best to store the unit Make sure to clean all the parts and have them dried before storage Meanwhile please loose the silicon washer to secure its service life 8 Do you know Do you know that different places have different humidities and objects need their own humidities too Please find the following e The Best Humidity for Human Body 45 RH 65 RH e The Best Humidity for Disease Preventing and Treatment 40 RH 55 RH e Furniture and Musical Instrument 40 RH 60 RH e Computer and Communication Apparatus 45 RH 60 RH e Dance Hall Bar and Other Public Places of Entertainment 40 RH 65 RH e Library Art Gallery Museum 40 RH 60 RH 9 Attentions A Itis not recommended to use additives like perfume essence etc It is prohibited to add alkaline substances into the water tank B When working do not touch the water in the groove or other parts lest electric shock may happen due to unexpected electric leakage C Do not direct the sprayer nozzle to children furniture and walls etc Adjust it to empty space instead 12 ENGLISH D Make sure it works far away from other home appliances E Do not leave it work on unstable surfaces When working do not tilt or overturn it F In case of abnormal noise or smell please turn it off and unplug it from socket immediately G When cleaning or moving the unit please turn it off and remove the water tank Shaking
5. aclare abundantemente b No sumerja la base en agua aseg rese de que al limpiarlo no entre agua en el ventilador c Nunca limpie el humidificador estando enchufado 7 Almacenaje La forma m s segura y adecuada de guardar su humidificador es en su embalaje origi nal Aseg rese de que su humidificador est bien limpio y seco antes de ser guardado 8 Sabe usted qu Sabe usted que en distintos lugares y distintos objetos necesitan distinta humedad Por favor tenga en cuenta la siguiente informaci n sobre la humedad relativa e La humedad relativa ideal para el cuerpo humano 45 RH 65 RH e La humedad relativa para el tratamiento y prevenci n de enfermedades 40 RH 55 RH e Para instrumentos musicales y muebles 40 RH 60 RH e Para ordenadores y aparatos de comunicaci n 45 RH 60 RH e Para sitios de ocio salas de baile bares y otros sitios p blicos 40 RH 65 RH e Librer as galer as de Arte museos 40 RH 60 RH 9 Atenci n A No a ada al agua aditivos ni esencias Cualquier sustancia alcalina a adida puede da ar el dep sito y el funcionamiento del humidificador B Cuando est funcionando no toque el agua en la base u otra parte pudiera tener una descarga el ctrica inesperada C No coloque el humidificador o dirija la salida de humedad directamente a ni os pa redes muebles o aparatos el ctricos Aseg rese de colocar el humidificador en una superficie plana y
6. as vibraciones y que divide las gotas de agua en min sculas part culas del tama o de 1 5 um Es entonces cuando a trav s del ventilador estas part culas se difunden en forma de niebla De esta forma el humidificador aporta humedad y refresca el aire de la habita ci n d nde est ubicado 5 C mo usar el humidificador A Latemperatura ambiente ideal para el correcto funcionamiento del humidificador es de 0 C a 40 C Col guelo en una habitaci n y compruebe el humidificador durante 1 h Y antes de su primer uso B En aquellas zonas donde el agua sea de una dureza alta se recomienda usar agua destilada La temperatura del agua no debe ser superior a los 40 C C Coja el dep sito de la base abra la tapa girando el tap n a la inversa de las agujas del reloj Llene el dep sito de agua aseg rese de que la arandela de silicona est coloca da en su sitio coloque el tap n y ci rrelo girando en el sentido de las agujas del reloj D Conecte el humidificador con el interruptor ON Ajuste apropiadamente la intensidad de humedad girando el control a m s o menos nebulizaci n 6 Limpieza y mantenimiento A Dep sito de agua a El dep sito de agua debe ser aclarado frecuentemente No es necesario usar ning n detergente s lo aclarar con agua limpia agitar el dep sito y vaciar Se recomienda una limpieza cada 3 d as si el uso del humidificador es continuado b No mantenga o guarde el humidificador con el
7. con espacio libre alrededor D No deje el humidificador en superficies inestables Cuando funcione el aparato no incline ni vuelque el humidificador E En el caso de que hiciese ruido o olor a quemado desconecte el enchufe inmedia tamente F Cuando lo limpie o mueva la unidad desconecte totalmente la unidad y quite el dep sito Cualquier agitaci n brusca puede inundar la base de agua y afectar al correcto funcionamiento del humidificador G No coloque el humidificador en lugares donde est expuesto directamente y durante un largo tiempo a la luz solar H No intente reparar o desmontar el aparato Consulte a su distribuidor para que sea reparado por los profesionales del SAT designado Cualquier modificaci n no autori zada o reestructuraci n del humidificador puede causar graves inconvenientes l Si no va a utilizar el humidificador por un largo periodo de tiempo desenchufe y gu rdelo apropiadamente CASTELLANO 10 Problemas y soluciones PROBLEMAS POSIBLE RAZON SOLUCION No nebuliza ni da brisa Da brisa pero no nebuliza Olor de la nebulizaci n Intensidad de nebulizaci n muy baja Salpica gotas de agua en lugar de nebulizar A No est enchufado B EI bot n est desconectado OFF C El nivel del agua es demasiado alto en la base D Fuga de agua en el dep sito A No hay agua en el dep sito B EI detector del nivel de agua no est en la posici n correcta El a
8. en eee eee eee 12 EE A 12 WO Trouble SNOMS lt lt a ee es et aA 14 1 Specifications Voltage 220 240V 50Hz Power 35W Water Tank 2 0L Maxium 400 ml h 2 Components Handle Water lid Sprayer Water tank Vent Indicator light Water groove Transducer Base Power switch Water level detector Mist intensity controller 3 General introduction Humidifier EPA PLUS is made of recyclable plastic of edible grade It can work continuously from 5 h to 10 h depending on the intensity Smooth mist power saving quiet auto stop and long service life are its main features 4 How it works As per the vibrating theory of ultrasonic waves the humidifier divides water drops into particles sized 1 5 um Then the particles are diffused by motor driven devices fan That s how this humidifier works to humidify and refresh the air 10 ENGLISH 5 How to use A The best environment temperature for the humidifier is ranged from 0 C to 40 C B It is recommended to use softened and boiled water or distilled water The water temperature should be no more higher than 40 C C Take the water tank from the base open the water lid by turning it anticlockwise fill in water make sure that the silicon washer is well fitted in its place and then close the water lid by turning it clockwise D Connect to power supply and turn on the switch Setting proper mist intensity by turning the mist intensity controll
9. er 6 Cleaning an manteinance A Water tank a The water tank should be rinsed frequently It is recommended to clean once every 3 days b Water should be changed frequently It should not be kept in the water tank more than 2 days B Transducer Due to geographic factors water quality may differ from place to place Some places have hard water which contains a large quantity of calcium and magnesium ions Furthermore the use of bleaching power to purify water also increases the hardness of water When this kind of water is used to humidify the air calcium and magnesium ions are diffused together with the mist As time goes on there will be sediments of scale on the object surfaces and ground Meanwhile there will also be sediments on the transducer and the water groove which is to affect the functioning of the humidifier To clean the transducer please a Add some cleanser about 0 5g on the transducer add some water and wait for 2 5 minutes b Use a soft brush to clean the surface of the transducer Don t use hard tools to scratch its surface c Use cleanser as packed with the appliance or other scale cleansers to be purchased in the market C Base a If the water groove and water level detector have scale sediments too please use the cleanser to clean and then wash the water groove with clean water b Do not immerse the base in water and make sure that no water enters the vent 7 Storage
10. gua se ha mantenido durante un tiempo estancada en el dep sito A Demasiada agua en la base B Control de intensidad de nebulizaci n al minimo C Sedimentos de cal en el transductor D Elagua es demasiado fria E Elagua no est limpia A Intensidad de nebulizaci n al minimo B La base y el dep sito no est n correctamente ensamblados C EI ventilador no funciona correctamente D La boguilla no est bien colocada o no est colocada A Ruido causado por que el dep sito est demasiado vacio B Ruido causado por estar colocado en una superficie inestable A Enchufe el humidificador a la red el ctrica B Conecte el bot n en posici n ON C Vac e el nivel de agua en la base D Apriete el tap n del dep sito A Llene el dep sito de agua B Vuelva a montar el detector del agua Limpie el dep sito y vuelva a llenarlo con agua limpia A Vac e la base de agua y coloque el dep sito lleno otra vez B Ajuste el control de intensidad C Limpie el transductor D Use agua a temperatura normal E Limpie el dep sito y vuelva a llenarlo con agua limpia A Ajuste el control de nebulizaci n B Aseg rese que est colocado el dep sito correctamente sobre la base C Contacte con el SAT para comprobar el ventilador D Aseg rese de que la boquilla esta bien colocada A A ada agua en el dep sito B Coloque la unidad en el suelo
11. o en una superficie estable Tarjeta de garantia Deseamos expresarle nuestro agradecimiento por la compra de un producto de Per xidos Farma c uticos S A Su fabricaci n ha sido efectuada con la m xima precisi n bajo el empleo exclusivo de materiales de alta calidad Este producto ha sido desarrollado para satisfacer las m s eleva das exigencias siempre que sea objeto de una correcta utilizaci n y un mantenimiento adecuado tal como figura descrito en las instrucciones de empleo Per xidos Farmac uticos S A concede para este producto un periodo de garant a de dos a os v lido a partir de la fecha de compra Per xidos Farmac uticos S A garantiza que la construc ci n la fabricaci n y el material de este producto son impecables Durante el periodo de garant a se proceder a la reparaci n o a la sustituci n de aquellos productos o componentes que presen ten desperfectos sin que se facturen los gastos de trabajo o las piezas de repuesto La garant a no cubre A Los gastos de transportes y por riesgo de transporte B Las reparaciones los costes de reparaci n y o aquellos desperfectos ocasionados por perso nas no autorizadas En el caso de detectar alguna anomal a en el producto le agradecer amos se pusiese en contacto con el Servicio de Atenci n al Cliente 902 999 319 preferentemente Si no resultara posible tambi n puede dirigirse a Per xidos Farmac uticos S A Gran Via de les Corts Catalanes 533 Barcelona
12. pairs and or defects resulting from repairs done by unauthorized persons If you detect any malfunction in this product please contact by phone with Customer Service 902 999 319 If it s not possible you can contact with Per xidos Farmace ticos S A Gran V a de les Corts Catalanes 533 Barcelona 08011 Spain C Periodic check ups maintenance and repair D Failure or wear of accessories or other attachments other than the main device itself Unless explicitly guaranteed above E Costs arising due to non acceptance of a claim those will be charged for F Damages of any kind including personal caused accidentally or from misuse G Repair or replacement under the guarantee does not give rise to any extension or renewal of the guarantee period The guarantee will be granted only if the complete product is retur ned together with the guarantee card and the original invoice cash ticket issued to the consumer by the retailer The guarantee card should be completed in full and Per xidos Farmace ticos S A reserves the right to refuse the guarantee service if any unclear information has been given European Representative Laboratorios Vitrotec C De l Art n 50 08041 Barcelona Spain DISTRIBUIDOR Per xidos Farmac uticos S A Gran Via de les Corts Catalanes 533 08011 BARCELONA www epaplus com tel fono de atenci n al consumidor 902 999 319
13. r of ordinary D The water is too cold temperature E The water is not clean E Clean the water tank and re fill it with clean water Mist spurts no high A Mist intensity controller is on A Ajust the controller the minimum side B Make sure water tank and the B Water tank and the base are base are touched rightly not rightly touched C Ask professionals to check the C Fan does not work properly fan inside the base A Resonance caused by too less A Add water into the water tank water in the water tank B Lay the unit on stable surfaces B Resonance caused by unstable surfaces 14 Guaranty card Thank you for buying an Per xidos Farmace ticos S A product This product is made with high guality materials and great care has been taken in its manufacturing It is designed to give you every satisfaction pro vided that itis properly operated and maintained as described in the ins truction manual This product is guaranteed by Per xidos Farmace ticos S A for a period of two years after the date of purchase The proper construction workmanship and materials of this product is guaran teed by Per xidos Farmace ticos S A During this period of guarantee Per xidos Farmace ticos S A will without charge for labour or parts repair or replace the defective product or any defec tive parts The guarantee does not cover any ofthe following A Transport costs and risks of transport B Costs for re
14. s may lead to overflow of water into the base so as to affect its function H Do not place it in sun lighted places for a long time Do not repair or replace parts by yourself send it to professionals or designated service center for help Unauthorized modifications or re structure of the humidifier may lead to inconveniences or dangers J If itis not to be used for a long time please unplug and store it properly 10 Trouble shootings TROUBLES REASONS POSSIBLE SOLUTIONS No breeze no mist A No power supply A Connect it to power supply B Power switch is off B Turn on the power switch C Water level of the groove is C Lower the water level by too high reducing water in the groove D Leakage of the water tank D Tighten the water lid Breeze but no mist A No water in the water tank A Fill water into the water tank B Water level detector is not in B Re mount the water level the right position detector C The temperature of the unit is C Place the unit in a room for half too low an hour before use Odd mist smell Water in the tank is kept for too Clean the water tank and re fill it long a time with clean water Low intensity A Too much water in the water A Empty the water in the groove groove and place the water B Mist intensity controller is on tank again the minimum side B Adjust the controller C Scale sediments on the C Clean the transducer transducer D Use wate