Home

Blood pressure monitor Instruction manual ....................2

image

Contents

1. 7 C mo guardar recuperar y borrar resultados 33 8 Cuidado mantenimiento y almacenamiento del INSTUMENTO caia ida 33 9 Mensajes de error y soluci n de problemas 10 Declaraci n de la FCC 11 Especificaciones t cnicas 12 Garant a CONSERVE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA Si el manual de instrucciones est da ado o si ya no lo tiene llame al servicio al cliente al 1 800 536 0366 Estimado cliente Felicidades por la compra de este tensi metro CVS pharmacy Lea estas instrucciones completamente y con atenci n antes de usar este producto y cons rvelas para referencia futura Aseg rese de tenerlas disponibles para otros usuarios y observe la informaci n que contienen 1 Conozca su instrumento El tensi metro para brazo se usa para medici n y monitoreo no invasivos de la presi n sangu nea arterial de adultos Usted pue de usarlo para medir su presi n sangu nea r pida y f cilmente guardando los resultados y mostrando el progreso de las lecturas junto con el promedio Los valores determinados se clasifican y eval an en forma gr fi ca de acuerdo con los est ndares de presi n sangu nea que es tablece el Departamento de Salud y Servicios Humanos de los Estados Unidos y los Institutos Nacionales de Salud USO PREVISTO Este dispositivo usa el m todo oscilom trico para medir la presi n sist lica y diast lica as como el ritmo car
2. Interferencia electromagn tica Evite los campos el ctricos o electromagn ticos fuertes cercanos al dispositivo como tel fonos celulares y hornos de microondas mientras est en operaci n ya que se pueden producir mediciones inexactas Para prevenir esa interferencia use la unidad a una distancia suficiente de estos dispositivos o ap guelos e No mida su presi n sanguinea mientras opera un veh culo o es t en una situaci n que exija toda su atenci n A PRECAUCI N e El dispositivo no se deber usar si hay lesiones o heridas en su brazo o cuando tiene un cat ter insertado Usarlo as puede producir lesiones 28 Retire toda clase de joyas y objetos similares del brazo antes de hacer una medici n Eso podr a causar moretones e No ponga el brazalete sobre ropa gruesa como una chaqueta ola manga de un su ter ya que el tensi metro no podr hacer una medici n adecuada y existe un alto riesgo de provocar un hematoma o dejar marcas en la piel durante el curso de la medici n En el caso de que el brazalete no deje de inflarse interrumpa la medici n al presionar el bot n ON OFF y abra el brazalete de inmediato e Al aplicar el brazalete aseg rese de que no haya arrugas en l Eso podr a causar moretones No ejerza ninguna clase de presi n en la manguera durante la medici n por ejemplo no ponga los brazos ni otro objeto sobre la manguera Esto podr a causar mediciones incorrectas Las m
3. Women who underwent a breast or axillar ymph node removal operation should consult a physician or licensed healthcare provider before starting blood pressure measurements Prior to use you have to ensure that the blood pressure monitor is free of damage If in doubt do not use the unit and contact customer service at 1 800 536 0366 This device is intended only for personal non commercial adult use in measuring blood pressure and heart rate Do not use the product for any other purpose This product is not intended for use in a hospital physician s office or any other health care facility e The unit must be used in accordance to the specified ambient conditions otherwise the accuracy of readings might be affect ed See section 8 Care maintenance and storing the instru ment and section 11 Technical Specifications for details Do not wrap the cuff around body parts other than your upper left arm Misuse represents a risk to your health Use this monitor only on humans This product is not intended for use by or on children toddlers and infants or on persons who cannot express their consent e g persons with mental disorders or the like Consult your physician for alternative methods of measuring a child s blood pressure Do not drape tube around neck This presents a strangulation hazard People with disabilities activity limitations or who are physic ally frail should be assisted by another person when using
4. many external factors influencing blood pressure it is unusual to obtain identical blood pressure measurements even when taken afew minutes apart Speak with your physician to determine what is affecting your blood pressure and which variation may be seen as normal in your case The accuracy of any blood pressure measurement with this device can be affected by a multitude of causes Some can be avoided some have to be accepted at the time of measurement Speak with your physician about possible causes affecting your blood pressure Do not inflate the cuff unless wrapped around arm e When taking repeat measurements make sure to select the same user so that the measurements are recorded in the appropriate memory e lf no button is pressed for one minute the automatic shut off function shuts off the unit in order to preserve the batteries Do not touch the unit the tube and cuff and or press any but tons when measurement is in progress except for stopping the measurement Doing so may cause incorrect readings 5 4 2 Taking Measurement Note If you are using the unit for the first time please remove the protective film from the display e Put on the cuff around your bare left upper arm as described previ ously and assume the position in which you want to carry out the measurement Using the buttons select the user memory 1 or 2 Start the measurement process by pressing the button After checking th
5. approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY ANY IMPLIED WARRANTIES OBLIGA TIONS OR LIABILITES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS APPLICABLE WRITTEN WARRANTY Some states do not allow limitations on how long an implied war ranty lasts so the above limitations may not apply to you IN NO EVENT SHALL THE WARRANTOR BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAM AGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS IMPLIED OR ANY OTHER THEORY OF LIABILITY WHATSOEVER Some states do not allow the exclusion or limita tion of special incidental or consequential damages so the above limitation may not apply to you The warrantor does not authorize anyone including but not limited to retailers the subsequent consumer purchaser of the product from a retailer or remote purchaser to obligate the warrantor in any way beyond the terms set forth herein This warranty does not extend to the purchase of opened used repaired repackaged and or resealed products including but not lim ited to sale of such products on Internet auction sites and or products by surplus or bulk resellers Any and all warranties or guarantees shall immediately cease and terminat
6. dedos debajo de l Inserte el tubo del brazalete en el recept culo en el lado izquierdo de la unidad Aseg rese de que se inserte firmemente en la unidad principal y de que no haya torceduras en el tubo del brazalete Importante Este instrumento solo debe usarse con el brazalete original El brazalete que se incluye con el dispositivo es adecuado para la circunferencia de un brazo de 9 a 13 23 a 33 cm Existe un brazalete mas largo para circunferencias de brazo de 13 a 17 33 a 43 cm que se puede obtener a traves de online at www cvs com No se pueden utilizar los brazaletes de reemplazo de otros modelos con este modelo De hacerlo se obtendr n lecturas imprecisas o mensajes de error 5 2 Postura correcta e Descanse al menos 5 minutos antes de ca da medici n De otro modo podr a obtener resultados err neos e Si ntese c modamente con el brazo iz quierdo apoyado en una superficie plana Aseg rese siempre de que el brazalete est al mismo nivel que el coraz n e Para no distorsionar el resultado es impor tante mantenerse inm vil durante la medi ci n y no hablar Los resultados de medici n m s precisos se obtienen si intenta lograr una situaci n de medici n relajada Puede cerrar los ojos y respirar con calma durante la medici n Tenga en cuenta que cualquier movimiento muscular durante el inflado y desinflado puede causar error en la medici n 5 3 Selecci
7. lica en Diast lica en Color presi n sangu nea mm de mm de Hg Hipertensi n en etapa 2 57 ent Pojo 160 179 100 109 Rojo Hipertensi n en etapa 1 140 159 90 99 Rojo Prehipertensi n 130 139 85 89 Amarillo 120 129 80 84 Verde claro Normal lt 120 lt 80 Verde oscuro Fuente Departamento de Salud y Servicios Humanos de los Estados Unidos e Institutos Nacionales de Salud 32 Nota Este est ndar o clasificaci n sin embargo es una pauta ge neral ya que la presi n sangu nea individual var a entre diferentes personas grupos de edad etc Consulte a su m dico para obtener un diagn stico adecuado Despu s de finalizar cada medici n aparece la gr fica de barras en la pantalla y la escala en la unidad indica el rango de la presi n sangu nea que se ha registrado Consulte la tabla de compara ci n anterior para ver a cu l etapa corresponde su resultado de medici n Nota Cuando las presiones sist lica y diast lica de una persona corresponden a diferentes categor as se deber aplicar la cate gor a m s alta por ejemplo presi n sist lica 181 y presi n diast lica 99 3 Categor a roja Hipertensi n en etapa 2 por ejemplo presi n sist lica 110 y presi n diast lica 95 gt Categoria roja Hipertensi n en etapa 1 Para adultos de 18 a os y mayores que no toman medicamento pa ra la presi n sangu nea alta que no tienen enfermedades serias de corto plazo y que no presentan otras condici
8. tumble dryer e Observe the local regulations for material disposal Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution e Batteries can contain toxins that are harmful to the environ ment Always dispose of batteries in accordance with applic able local regulations Do not dispose of batteries with normal household waste Never attempt to repair open and or disassemble the unit in cluding arm cuff and optional accessory or adjust it yourself This may damage the unit and impair the functions If you need to have the unit repaired please contact our customer service Please see warranty for service contact Before submitting any complaint first check the batteries and replace them if neces sary e Changes or modifications to the device will nullify the user warranty Do not drop or insert any object into any opening or hose This may damage the unit Do not press the buttons with excessive force or with pointed objects To keep your digital blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below Clean your device and cuff carefully only with a slightly moistened soft cloth and dry it immediately with a soft dry cloth Do not press e When storing the device make sure that no heavy objects are placed on top of it Do not fold the cuff and tubing tightly
9. 18 and not to be used on children 2 Package Contents Blood Pressure monitor BM35 Arm cuff arm circumference 9 13 23 33 cm e Operating instructions e Storage bag e 4x 1 5 V AAA battery 3 Device description 3 1 Unit 21 1 Cuff tube 6 ON OFF button 2 Cuff 7 Display 3 Cuff connector 8 Risk category indicator 4 Cuff connector port 9 Function key 5 left side 10 Adjustment button 5 Memory button MEM 3 2 Display Explanations 1 Time and date 2 Average of the last three m K E Eb measurements 8 3 mmHg unit SG am mh 4 battery icon i bu al al 5 5 Number of memory oy x Lg space T a gt 6 Irregular heartbeat icon H Uy m 10 7 Measured heart rate 8 Systolic pressure rm Li 9 Diastolic pressure Ll 10 Risk category indicator 11 Error icon EE nn 1 12 Icon for users 1 2 vi na 112 13 Heart rate icon Y noi 13 For product information questions or customer service call toll free 1 800 536 0366 4 Prepare measurement 4 1 Inserting Replacing batteries A VVARNING Swallowing batteries and or battery fluid can be extremely dangerous Keep the batteries and the unit out of the reach of children and disabled persons Should any person swallow a battery and or battery fluid please call 911 immediately e Batteries should not be charged or reactivated by
10. CVS Drive Woonsocket RI 02895 O 2011 CVS pharmacy www cvs com 1 800 shop CVS Wa CVS Quality Money Back Guarantee 38 39 ebueyo pue Joa o i lqns 2101 206692 ay as uy PLEASE RECYCLE 40
11. No use solventes limpiadores detergentes u otros qu micos da inos para limpiar el dispositivo e Nunca sumerja la unidad en agua u otros l quidos ni derrame agua o l quidos sobre el tensi metro ya que stos entrar n en l y lo da ar n e No lave esta unidad en una lavadora de ropa m quina lavapla tos o secadora de ropa 23 Aplique las normas locales para desecho de materiales Des eche el dispositivo componentes y accesorios opcionales de acuerdo con las regulaciones del lugar donde vive El desecho indebido puede causar contaminaci n ambiental e Las bater as pueden contener toxinas nocivas para el medio ambiente Deseche siempre las bater as de acuerdo con las normas locales correspondientes No deseche las bater as junto con la basura dom stica normal Use siempre el tama o y tipo de bater a indicados Si usa otras bater as da ar el dispositivo e Nunca use diferentes tipos de bater as marcas de bater as O bater as de diferente capacidad Esto puede da ar la unidad De preferencia use bater as alcalinas e Nunca use bater as recargables Esto puede da ar la unidad Reemplace siempre todas las bater as al mismo tiempo y use bater as del mismo tipo Reemplace las bater as con poca carga antes de que se des carguen completamente Cambie las bater as cuando aparezca ten la pantalla Las bater as con fuga pueden da ar el dispositivo Si no va a usar la unidad durante un perio
12. bater as 4 2 Ajuste de la fecha y hora Es esencial ajustar la fecha y hora Esta es la nica forma en que pueden guardarse y recuperarse las mediciones con la fecha y hora correctas La hora se muestra en un formato de 12 horas Proceda como sigue para ajustar la fecha y hora Encienda el tensi metro con el bot n e Presione el bot n de funci n por m s de 5 segundos e El mes empieza a parpadear Presione el bot n para cambiar el mes Cada vez que lo presiona aumentar el n mero de uno en uno de manera c clica Ajuste el mes de 1 a 12 y confirme con el bot n de funci n Ajuste el dia 1 2 3 31 hora 1 2 3 11 12 pm 1 PM 11 pm 12 y minuto 00 01 02 03 59 en la misma manera y confirme con el bot n de funci n 5 Medici n de la presi n sangu nea A ADVERTENCIA e Consulte a su m dico antes de comenzar a medir su presi n sangu nea e Lea y comprenda todas las instrucciones y advertencias antes de usar este dispositivo Al igual que con cualquier dispositivo oscilometrico de me dici n de la presi n sangu nea algunas afecciones pueden afectar la exactitud de la medici n entre otras trastorno del ritmo cardiaco presi n sangu nea muy baja pacientes de estado de shock pacientes con perfusi n sangu nea muy baja diabetes anormalidades en vasos sangu neos personas con implantes el ctricos como marcapasos mujeres
13. diagnosis or seek medical advice Please note that this device does not diagnose hypertension and it is only for user reference on blood pressure monitoring 7 Saving retrieving and deleting results The results of each successful measurement are stored together with date and time Each user can store up to 60 items of meas ured data With more than 60 items of measured data the oldest items of measured data are dropped Select the desired user memory by pressing the MEM button and then the button Press the MEM button again to display the average of the last 3 measurements in the user memory If you continue pressing the MEM button the latest individual results are displayed with the risk category indicator irregular heart beat icon date and time Press MEM button to read the following measure ments in sequence Data is recalled from the latest measurement to the oldest To stop reading the memory press the button Note If there is no data in the selected user nothing except date time and user number will appear on the display e To clear the memory press the MEM button then the display shows no 1 Press the button to select the user memory and confirm by pressing MEM again Press and hold the and 5 keys simultaneously for 5 seconds the display will show CLA To confirm the data in the selected user has been erased press MEM button and no data should appear except date time and th
14. equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 11 Technical Specifications Model No BM 35 Method of oscillometric non invasive blood pressure Measurement measurement on the upper arm Measurement cuff pressure range 0 300 mmHg Range blood pressure range 40 280 mmHg heart rate 40 199 beats minute Storage and trans 4 F to 158 F 20 C to 70 C lt 90 RH port temperature Power Supply 4 x 1 5 V AAA Batteries alkaline type LR03 Battery Life for approx 250 measurements depending on blood pressure level or inflation pressure Accessories storage bag operating instructions 4 AAA batteries 1 Internally powered equipment X BF type applied part IPXO Not suitable for use in presence of flam mable anesthetic mixture vvith air or vvith Oxygen or nitrous oxide Continuous operation with short time loading BF Classification Accuracy of the systolic 3 mmHg diastolic 3 mmHg reading heart rate 5 of the displayed value Measuring max permissible standard deviation according uncertainty to clinical testing systolic 8 mmHg diastolic 8 mmHg Sets of Memory 2 x 60 memory places 120 memory total L5 3 x W 4 1 x H 2 1 L 135 mm x W 105 mm x 53 mm Unit Dimension Unit Weight approx 0 48 Ib 217 9 Cuff Size upper arm ci
15. explode Should battery fluid leak and come into contact with your eyes or skin immediately rinse with plenty of clean water Please call 911 immediately This product is not intended for use by or on children toddlers and infants or on persons who cannot express their consent e g persons with mental disorders or the like Consult your physician for alternative methods of measuring a child s blood pressure A VVARNING e This product is not a toy Keep it out of reach of children tod dlers and infants Keep the product out of the reach of pets e Packaging materials are a deadly hazard for children and can cause suffocation Remove all packaging materials immediately and keep them away from children at all times This product contains small parts that may present a choking hazard to children Keep the unit and all parts out of reach of children NEVER LEAVE CHILDREN OR THOSE WHO REQUIRE CLOSE SUPERVISION UNATTENDED WITH THIS DEVICE The tubing presents a strangulation hazard Keep this product away from children and those who require close supervision e g people with mental disorders NEVER LEAVE CHILDREN OR THOSE WHO REQUIRE CLOSE SUPERVISION UNATTEND ED WITH THIS DEVICE Do not drape tube around neck This presents a strangulation hazard People with disabilities activity limitations or who are physic ally frail should be assisted by another person when using this unit Proper cuff size is important for accurate mea
16. in a cycling manner Set the month 1 to 12 and confirm with the function key e Set the day 1 2 3 31 hour 1 2 3 11 12 pm 1 PM 11 pm 12 and minute 00 01 02 03 59 in the same manner and confirm in each case with the function key 5 Measuring blood pressure A VVARNING e Consult your physician before starting to measure your blood pressure e Read and understand all instructions and warnings before using this device e Like any oscillometric blood pressure measurement devices certain medical conditions can affect the measurement ac curacy among others disorder of the cardiac rhythm very low blood pressure patients in shock patients with very low blood perfusion diabetes vessel anomalies people with electrical implants such as a cardiac pacemaker women who are pregnant Due to their condition the oscillometric measurement method can produce incorrect readings This represents a risk for your health since values may be interpreted incorrectly Always con sult your physician to determine what will be suitable for you e Never try to adapt or plug this device to the AC line This device is battery powered e This product is not intended to serve as a substitute for the advice of a physician or medical professional This product is not intended to substitute for regular medical checkups Con tact your physician for specific information about your blood pressure
17. inflating interrupt the measure ment by pressing the ON OFF button and open the cuff at once If a battery has leaked do not touch the battery fluid Avoid skin contact e g put on protective gloves and clean the battery compartment with a dry cloth Do not disassemble the unit it may result in injuries e When applying the arm cuff make sure there are no wrinkles in the cuff This could cause bruises Do not exert any kind of pressure on the hose during measure ment e g laying your arms or any other obiect on the hose This could cause incorrect measurements Blood pressure measurements can lead to temporary marks on the skin at the site of the cuff placement This is especially the case in high repetition rates in hypertonic patients and in patients with weak heart rates In rare cases a mark may persist for a couple of days Please contact your physician about these specific risks of cuff pressure in your specific case A CAUTION For hygienic reasons the cuff is intended only for the use by one person NOTICE e The blood pressure monitor is made up of precision electronic components Accuracy of readings and the instrument s ser vice life depend on careful handling Protect the unit against hard knocks e g dropping the unit moisture water dirt dust chemicals extreme hot or cold temperatures major temper ature fluctuations direct exposure to sunlight and heat sources which are too close e g
18. la memoria del usuario Si contin a presionando el bot n MEM se muestran los ltimos resultados individuales con el indicador de categor a de riesgo cono de ritmo cardiaco irregular y fecha y hora Presione el bot n MEM para leer las mediciones siguientes en secuencia Los datos se recuperan a partir de la medici n m s reciente hasta la m s antigua e Para dejar de leer la memoria presione el bot n Nota Si no hay datos del usuario seleccionado no aparecer nada en la pantalla excepto la fecha hora y n mero de usuario e Para vaciar la memoria presione el bot n MEM entonces la pan talla muestra el n 1 Presione el bot n para seleccionar la memoria del usuario y confirme al presionar nuevamente MEM Presione y mantenga as el bot n y los botones al mismo tiempo durante 5 segundos la pantalla mostrar CLA Para con firmar que los datos del usuario seleccionado se han borrado presione el bot n MEM y no deber n aparecer datos excepto la fecha hora y n mero de usuario e Si desea cambiar la memoria de usuario vea Seleccionar me moria 8 Cuidado mantenimiento y almacenamiento del instrumento A ADVERTENCIA No use brazaletes tubos piezas ni accesorios que no sean los que recomienda expl citamente el fabricante para este produc to Las partes y accesorios no aprobados para usarse con este dispositivo pueden afectar a su salud y al producto A PRECAUCI N No
19. las lecturas podr a verse afectada Vea la secci n 8 Cuidado mantenimiento y almacenamiento del instrumento y la secci n 11 Especificaciones t cnicas para m s detalles No se envuelva el brazalete en ninguna parte del cuerpo que no sea su brazo izquierdo El mal uso representa un riesgo para su salud Use este monitor solo en humanos A ADVERTENCIA e Este producto no es para usarse en ni por ni os ni os peque os infantes ni en personas que no puedan expresar su consen timiento es decir personas con trastornos mentales o similares Consulte a su m dico para conocer m todos alternos para medir la presi n sangu nea de un ni o No envuelva el tubo alrededor del cuello Esto representa riesgo de estrangulaci n Las personas con discapacidades limitaciones en su actividad o que son f sicamente fr giles deben recibir asistencia de otra persona cuando usen esta unidad El tama o de brazalete adecuado es importante para obtener mediciones exactas Use el instrumento solamente en personas adultas cuyo brazo tenga la circunferencia adecuada para el instrumento Vea la secci n 11 Especificaciones t cnicas para informaci n de circunferencias del brazo adecuadas No use brazaletes tubos piezas ni accesorios que no sean los que recomienda expl citamente el fabricante para este produc to Las partes y accesorios no aprobados para usarse con este dispositivo pueden afectar a su salud y al producto
20. stoves heating radiators This may damage the unit The device must be stored in the specified ambient conditions Please see section 8 Care maintenance and storing the instrument and section 11 Technical Speci fications for details Do not use any aggressive solvents cleaning agents deter gents or any other strong chemicals to clean the device Never immerse and or spill water or any other liquid onto the monitor or any components otherwise liquid will enter it and cause damage Do not wash the unit in a washing machine dish washer or tumble dryer Observe the local regulations for material disposal Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution Batteries can contain toxins that are harmful to the environ ment Always dispose of batteries in accordance with applic able local regulations Do not dispose of batteries with normal household waste e Always use the size and type of battery indicated The use of other batteries will damage the device Never use different types of batteries battery brands or bat teries with different capacities This may damage the unit You should preferably use alkaline batteries Never use rechargeable batteries This may damage the unit Always replace all batteries at the same time and use batteries of the same type e Replace weak batteries before they discharge comp
21. the bend of the elbow and above the artery The tube should be in line with the center of the palm Now place the free end of the cuff snugly but not too tightly around the arm and fix it with the Velcro fastener The cuff should be fitted tight enough to allow just two fin gers to fit beneath the cuff Insert the cuff tubing into the socket on the left side of the unit Make sure it is in serted securely in the main unit and that there are no kinks in the cuff tubing Important This instrument should only be operated with the original cuff The cuff included with the device is suitable for an upper arm circumference of 9 to 13 23 to 33 cm A larger cuff for upper arm circumferences from 13 to 17 33 to 43 cm is available online at www cvs com Replacement cuffs from other models cannot be used with this mod el Doing so will result in inaccurate readings or error messages 5 2 Correct posture e Rest at least for 5 minutes before each meas urement Othervvise there may be erroneous results Sit comfortably with your left arm resting on a flat surface Always make sure that the cuff is on a level with your heart e n order not to distort the result it is important to keep still during the measurement and not talk The most precise measurement results are obtained if you strive for a relaxed meas urement situation You may close your eyes and breathe calmly during the mea
22. this unit A VVARNING Proper cuff size is important for accurate measurements Only use the instrument on adult persons vvhose upper arm has the right upper arm circumference for the instrument See sec tion 11 Technical Specifications for suitable arm circumfer ences Do not use any cuffs tubes parts and accessories other than those explicitly recommended by the manufacturer for use with this product Parts and accessories not approved for use with the device may cause damage to your health and to the product Electromagnetic interference Avoid strong electrical or elec tromagnetic fields in the direct vicinity of the device e g mo bile telephones microvvave ovens while it is in operation as inaccurate measurements may result To prevent such interfer ence use the unit at a sufficient distance from such devices or turn the devices off e Do not measure your blood pressure while operating a vehicle or in any situation which requires your full attention A CAUTION e The device should not be used when your arm has been wound ed iniuried or when a catheter has been inserted Such use may result in iniury e Remove any kind of upper arm jewelry or the like before taking a measurement This could cause bruises Do not place the arm cuff over heavy clothing e g a jacket or sweater sleeve as the blood pressure monitor will not be able to take a proper measurement and there is an elevated danger of acquiring hem
23. Model BM 35 tem 708884 pharmacy Modelo BM 35 N mero de art culo 708884 Blood pressure monitor Instruction manual 2 Tensi metro Manual de instrucciones 20 READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE USING THIS PRODUCT Keep this manual in a safe location for future reference LEA TODO ESTE MANUAL CON ATENCI N ANTES DE USAR ESTE PRODUCTO Conserve este manual en un lugar seguro para consultarlo en el futuro ENGLISH MPORTANT SAFETY NOTES Signs and symbols The follovving signs appear in the Safety Section pages 2 3 4 5 and in this manual on pages 8 9 10 12 13 15 17 READ THIS ENTIRE MANUAL THE SAFETY SECTION AND ALL INSTRUCTIONS AND WARNINGS COMPLETELY AND CARE FULLY BEFORE USING THIS PRODUCT FOLLOVV ALL SAFETY INSTRUCTIONS AND VVARNINGS TO AVOID HAZARDOUS SITU ATIONS AND TO MAKE CORRECT USE OF THIS PRODUCT WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided may result in minor or moderate injury NOTICE addresses practices not related to personal injury such as product and or property damage e Consult your physician before starting to measure your blood pressure Read and understand all instructions and warnings before using this device Like any oscillometric blood pressure measurement devices certain medical c
24. RESPONSABLE DE CUALESQUIER DANOS ESPECIALES INCIDENTALES INDI RECTOS O CONSECUENTES POR INCUMPLIMIENTO DE ESTA O DE CUALQUIER OTRA GARANT A EXPRESA IMPL CITA O POR CUALQUIER OTRA TEOR A DE LA RESPONSABILIDAD DE CUALQUIER TIPO Algunos estados no permiten la exclusi n O limitaci n de da os especiales incidentales o consecuentes de manera que la limitaci n anterior podr a no ser aplicable para usted El garante no autoriza a ninguna persona incluyendo pero sin limitarse a vendedores minoristas al comprador consumidor subsi guiente del producto de un vendedor minorista o comprador remo 37 to a obligar al garante en cualquier forma mas alla de los t rminos establecidos en la presente Esta garant a no se extiende a la compra de productos abiertos usados reparados reempaquetados y o resellados incluyendo pero sin limitarse a la venta de dichos productos en sitios de subasta de Internet y o productos de revendedores de excedentes o en volu men Cualesquier garant as cesar n y terminar n inmediatamente en relaci n a productos o partes de los mismos que sean reparadas reemplazadas alteradas o modificadas sin el consentimiento expl cito por escrito de parte del garante Esta garant a le da derechos espec ficos y usted puede tambi n tener otros derechos que pueden variar de un estado a otro Hecho en China Preguntas o comentarios Llame gratis al 1 800 536 0366 Distribuido por CVS Pharmacy Inc One
25. The cuff tube should not have any sharp kinks and keep it away from sharp edges 15 e f the unit is stored near freezing allow it to acclimate to room temperature before use e Always store the unit in the pouch after use This unit may not meet its performance specifications if stored or used outside of the temperature and humidity ranges see section 11 Technical Specifications e Use the unit consistent with the instruction provided in this manual 9 Error messages troubleshooting If any abnormality arises during use please check the following points Error Display Possible Causes Correction Symptoms EE Pressure is lower than Repeat the measure 40 mmHg or Effective ment Make sure that heart rate is lower than the cuff is positioned 4 beats correctly the cuff tube El The cuff is inflated for iS Properly inserted and longer than 25 seconds that you do not move or talk Re insert the The cuff tube is not batteries if necessary inserted properly or else replace them E2 Inflation pressure is higher than 300 mmHg E3 Blood pressure is un usually high or low You move or talk dur ing the measurement in addition to E3 the irregular heartbeat icon 96 appears in the display 16 Error Display Possible Causes Correction Symptoms Unit does not Batteries have run down Replace the batteries tum on when Battery po
26. a etapa temprana Consulte siempre a un m dico para determinar qu es lo m s adecuado para usted e La funci n ritmo cardiaco irregular no est dise ada pa ra diagnosticar ni tratar una arritmia Solo un m dico puede diagnosticar la arritmia e La tabla Indicador de categor a de riesgo no tiene el prop sito de reemplazar el diagn stico m dico Esta tabla es solo una referencia para diferentes clasificaciones de la presi n san gu nea 21 Si observa variaciones anormales o sospechosas en las me diciones de presi n sangu nea consulte a su m dico inme diatamente e Las mujeres que se sometieron a una operaci n para extirpar una mama o un nodo linf tico axilar deber n consultar a un m dico antes de comenzar a hacer mediciones de presi n sangu nea e Antes de usarlo aseg rese de que el tensi metro no est da ado En caso de duda no use la unidad y llame al servicio al cliente al tel fono 1 800 536 0366 Este dispositivo es solo para uso personal no comercial y en adultos para medir la presi n sangu nea y el ritmo cardiaco No use el producto para ning n otro prop sito Este producto no es para usar en un hospital consultorio m dico o ning n otro centro de atenci n m dica e La unidad se debe usar de conformidad con las condiciones ambientales especificadas de otro modo la exactitud de las lecturas podr a verse afectada Vea la secci n 8 Cuidado mantenimiento y almacenamiento del
27. agn stico y el tratamiento por ejemplo respecto a medicamentos basados en los resultados de las mediciones representan un riesgo para su salud Consulte siempre con un m dico para determinar el medicamento adecuado y su dosis Siga las instrucciones de su m dico o proveedor de atenci n m dica autorizado Si tiene un problema m dico o sospecha tenerlo consulte inmediatamente a su m dico Si se le presenta una emergencia llame al 911 de inmediato e Solo un m dico o un profesional capacitado de salud que est familiarizado con su historial m dico podr interpretar con exac titud sus mediciones de presi n sangu nea Consulte a su m dico antes de comenzar un monitoreo de la presi n sangu nea Observe que son posibles tolerancias de medici n t cnicamente relacionadas Vea la secci n 11 Especificaciones t cnicas para m s detalles e Si observa variaciones anormales o sospechosas en las medi ciones de presi n sangu nea consulte a su m dico inmedia tamente Nota Una sola medici n no ofrece una indicaci n exacta de su verdadera presi n sangu nea Debe tomar varias lecturas y regis trarlas durante alg n tiempo Intente medir su presi n sangu nea cada d a a la misma hora para tener uniformidad 31 6 1 Simbolo de ritmo cardiaco irregular A ADVERTENCIA La funci n ritmo cardiaco irregular no reemplaza un examen car diaco pero puede ayudar a detectar irregularidades potenciales en el rit
28. an This symbol Wy indicates that certain heart rate irregularities were detected during the measurement In general an irregular heartbeat rhythm is defined as a rhythm that is more than 25 slower or 25 faster from the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure In order to filter the unstable status of user and avoid affecting the detection of heart rate from any movement shaking or talking in the beginning of measurement the method of averaging heart beat inter vals of subject device is calculated with the three proper heart beat pulses detected in the beginning of measurement and that is different from a strict mathematical averaging of all recorded intervals At least 3 beats with at least 25 difference from the average heart beat interval will generate the IHB icon on the screen NOTE e Talking moving shaking or an irregular heart rate during the meas urement can result in the appearance of this symbol Repeat the measurement if the flashing icon is displayed after the measurement Please note that you should rest at least 5 minutes between measurements and not talk or move during the meas urement If the icon continues to be displayed in subsequent readings we recommend you to consult your physician in order to determine if it is cause for concern Do not try to interpret read ings or attempt to treat any condition yourself Always follow the guidance of a health
29. any other means The batteries may explode e Batteries should not be taken apart thrown in the fire or short circuited The batteries may explode Should battery fluid leak and come into contact with your eyes or skin immediately rinse with plenty of clean water Please call 911 immediately A CAUTION e If a battery has leaked do not touch the battery fluid Avoid skin contact e g put on protective gloves and clean the battery compartment with a dry cloth NOTICE Batteries can contain toxins that are harmful to the environ ment Always dispose of batteries in accordance with applic able local regulations Do not dispose of batteries with normal household waste e Always use the size and type of battery indicated The use of other batteries will damage the device e Never use different types of batteries battery brands or bat teries with different capacities This may damage the unit You should preferably use alkaline batteries e Never use rechargeable batteries This may damage the unit Always replace all batteries at the same time and use batteries of the same type e Replace weak batteries before they discharge completely When h t appears in the display please change the batteries Leaking batteries may damage the device If you do not intend to use the unit for longer periods remove the batteries from the battery compartment before placing the device in storage Note You can only operate the blo
30. as se ubicaron bater as en la posici n n incorrectamente correcta ot n Q 2 P La unidad est defec Comun quese con el tuosa Servicio al cliente Vea la secci n de garant a Las bater as se agotaron Reemplace las bater as Los valores La presi n sanguinea Consulte la secci n de las medi var a constantemente 5 Medici n de la ciones son factores como el presi n sanguinea demasiado estr s la hora del d a c altos o mo colocarse el brazalete demasiado y otros pueden afectar a bajos la presi n sangu nea Nota Si aparece EP en la pantalla comun quese con el servicio al cliente Vea la secci n de garant a Nota Si a n no funciona la unidad llame al servicio al cliente al 1 800 536 0366 10 Declaraci n de la FCC Este equipo ha sido probado y se determin que cumple con los l mites para los dispositivos digitales Clase B de acuerdo con la parte 15 de las reglas de la FCC Estos l mites sirven para proporcionar protecci n razonable contra la interferencia da ina en instalaciones residenciales Este equipo genera usa y puede emitir energ a de frecuencia de radio y si no se instala y usa de acuerdo con las instrucciones puede causar interferencia da ina a recepciones de radio o televisi n lo cual puede determinarse al apagar y encender el equipo Se recomienda al usuario tratar de corregir la interferencia mediante una o m s de las siguie
31. atoma or skin marks during the course of the measurement 10 n case the cuff does not stop inflating interrupt the measure ment by pressing the ON OFF button and open the cuff at once When applying the arm cuff make sure there are no wrinkles in the cuff This could cause bruises Do not exert any kind of pressure on the hose during measure ment e g laying your arms or any other object on the hose This could cause incorrect measurements Blood pressure measurements can lead to temporary marks on the skin at the site of the cuff placement This is especially the case in high repetition rates in hypertonic patients and in patients with weak heart rates In rare cases a mark may persist for a couple of days Please contact your physician about these specific risks of cuff pressure in your specific case For hygienic reasons the cuff is intended only for the use by one person 5 1 Positioning cuff Note Always properly position the Arm Cuff on the arm at heart level according to the following instructions Fit the cuff round your bare left upper arm Do not place the arm cuff over heavy clothing e g a jacket or sweater sleeve as the blood pressure monitor will not be able to take a proper measurement Blood circulation in the arm should not be re stricted by tight clothing or other objects The cuff should be placed on the upper arm so that the lower edge is approx 0 8 to 1 2 2 to 3 cm above
32. ausar asfixia Retire de inmediato todos los materiales de embalaje y mant ngalos alejados de los ni os en todo momento Este producto contiene piezas peque as que pueden repre sentar riesgo de asfixia para los ni os Mantenga la unidad y todas las piezas lejos del alcance de los ni os NUNCA DEJE A NINOS QUE REQUIERAN SUPERVISI N ESTRECHA SOLOS CON ESTE DISPOSITIVO El tubo representa un riesgo de estrangulaci n Mantenga este producto lejos del alcance de los ni os y de quienes necesiten supervisi n tal como las personas con trastornos mentales NUNCA DEJE A NI OS QUE REQUIERAN SUPERVISI N ES TRECHA SOLOS CON ESTE DISPOSITIVO No envuelva el tubo alrededor del cuello Esto representa riesgo de estrangulaci n Las personas con discapacidades limitaciones en su actividad o que son f sicamente fr giles deben recibir asistencia de otra persona cuando usen esta unidad El tama o de brazalete adecuado es importante para obtener mediciones exactas Use el dispositivo solo en adultos que tengan la circunferencia de brazo derecho adecuada para este instrumento Vea la secci n 11 Especificaciones t cnicas para informaci n de circunferencias del brazo adecuadas 22 No use brazaletes tubos piezas ni accesorios que no sean los que recomienda expl citamente el fabricante para este produc to Las partes y accesorios no aprobados para usarse con este dispositivo pueden afectar a su salud y al producto Interfere
33. deleting results 8 Care maintenance and storing the instrument 9 Error messages troubleshooting 10 FCC Statement 11 Technical Specifications 12 epi ot E EN SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE If the instruction manual is damaged or if you no longer have the instruction manual in your possession please contact customer service at 1 800 536 0366 Dear Customer Congratulations on your purchase of this CVS pharmacy6 blood pressure monitor Please read and understand these instructions completely and carefully before using this product and keep them for later reference Be sure to make them accessible to other users and observe the information they contain 1 Getting to know your instrument The upper arm blood pressure monitor is used for non invasive measurement and monitoring of adults arterial blood pressure You can use it to measure your blood pressure quickly and eas ily storing the results and displaying the progression of readings together with the average The values determined are classified and graphically evaluated according to the blood pressure standards established by the U S department of Health and Human Services and the National Institutes of Health INTENDED USE This device uses the oscillometric method to measure systolic and diastolic blood pressure as well as your heart rate It s rec ommend for use by people over the age of
34. desarme la unidad esto puede causar lesiones AVISO e El tensi metro est integrado por componentes electr nicos de precisi n La precisi n de las lecturas y la vida de servi cio del instrumento dependen del manejo cuidadoso Proteja esta unidad de golpes fuertes como dejarla caer humedad agua suciedad polvo qu micos temperaturas demasiado altas o bajas cambios dr sticos de temperatura y expo sici n a la luz solar directa y a fuentes de calor demasiado cercanas como estufas y radiadores de calor Esto puede da ar la unidad El dispositivo debe guardarse en las con diciones ambientales especificadas Vea la secci n 8 Cui dado mantenimiento y almacenamiento del instrumento y la secci n 11 Especificaciones t cnicas para m s detalles No use solventes agresivos limpiadores detergentes u otros qu micos fuertes para limpiar el dispositivo Nunca sumerja la unidad en agua u otros l quidos ni derrame agua o l quidos sobre el tensi metro ya que stos entrar n en l y lo da ar n No lave esta unidad en una lavadora de ropa m quina lavapla tos o secadora de ropa 33 AVISO e Aplique las normas locales para desecho de materiales Des eche el dispositivo componentes y accesorios opcionales de acuerdo con las regulaciones del lugar donde vive El desecho indebido puede causar contaminaci n ambiental e Las bater as pueden contener toxinas nocivas para el medio ambiente Desech
35. diaco Se recomienda su uso en personas mayores de 18 a os y que no se use en ni os 2 Contenido del paquete e Tensi metro BM35 Brazalete circunferencia del brazo de 9 13 23 33 cm e Instructivo de uso e Bolsa de almacenamiento e 4 bater as AAA de 1 5 V 3 Descripci n del dispositivo 3 1 Unidad 21 1 Tubo para brazalete 6 Bot n ON OFF 2 Brazalete 7 Pantalla 3 Conector del brazalete 8 Indicador de categor a de 4 Orificio del conector del riesgo brazalete lado izquierdo 9 Bot n de funci n 5 Bot n de memoria MEM 10 Bot n de ajuste 3 2 Explicaciones de la pantalla 1 Hora y fecha 2 Promedio de las tres m K E Eb ltimas mediciones al 8 3 Unidad de mm de Hg fan Lil R 4 cono Cambio de 4 bater a x a Y F 5 N mero de espacio de o ty x tb memoria T a gt 6 cono de ritmo cardiaco pij H irregular Wy a 10 7 Ritmo cardiaco medido 8 Presi n sist lica rm ZE 9 Presi n diast lica Lim 10 Indicador de categor a de riesgo 11 cono de error EE a 12 cono para usuarios 1 2 vi na llas 13 cono de ritmo cardiaco Y noi 13 Para obtener mas informaci n relacionada con el producto con sultar dudas o ponerse en contacto con el servicio al cliente llame gratis al 1 800 536 0366 25 4 Preparaci n de la medici n 4 1 Inserci n y reemplazo de las bate
36. do de auscultaci n con brazalete y estetoscopio y est n dentro de los l mites de precisi n que prescribe el Est ndar Nacional Norteamericano para Esfigmoman metros Electr nicos o Automatizados Se recomienda que el funcionamiento se verifique cada 5 a os o despu s de la reparaci n Llame al servicio al cliente 12 Garant a Garant a limitada de por vida de la compra original Su tensi metro CVS pharmacy modelo BM35 excluyendo el brazalete incluyendo el tubo y las bater as est garantizado de estar libre de defectos de materiales y mano de obra durante la duraci n del producto bajo condiciones normales del uso y servicio previstos El brazalete est garantizado de estar libre de defectos en materiales y mano de obra que aparezcan en un plazo de dos a os a partir de la fecha de compra cuando el monitor se usa de conformidad con las instrucciones proporcionadas con la unidad Esta garant a se aplica solamente al comprador original y no se extiende a vendedores minoristas o futuros propietarios Repararemos o reemplazaremos a discreci n nuestra el tensi me tro CVS pharmacy modelo BM35 sin ning n cargo adicional por cualquier parte o partes cubiertas por estas garant as escritas No se har n reembolsos La reparaci n o reemplazo es nuestra nica responsabilidad y el unico recurso de usted bajo esta garant a escri ta Si no hay partes de reemplazo para los materiales defectuosos el garante se reserva el der
37. do largo retire las bater as de su compartimiento antes de guardar el dispositivo Nunca trate de reparar abrir o desarmar esta unidad incluyen do el brazalete y el accesorio opcional ni de ajustarla usted mismo Podr a da ar la unidad e impedir su funcionamiento correcto Si la unidad requiere reparaci n llame a nuestro ser vicio al cliente Vea en la garant a la informaci n de contacto de servicio Antes de presentar cualquier queja revise las bater as y reempl celas si es necesario e Los cambios o modificaciones en el dispositivo anularan la garant a del usuario e No permita que caiga ni introduzca ning n objeto por ninguna abertura o manguera Esto puede da ar la unidad No presione los botones con fuerza excesiva o con objetos punzantes Contenido NOTAS IMPORTANTES DE SEGURIDAD A ADVERTENCIA A PRECAUT N 22 Conozca su instrumento Contenido del paquete Descripci n del dispositivo 3 1 Unidad 3 2 Explicaciones de la pantalla 4 Preparaci n de la medicion 4 1 Inserci n y reemplazo de las baterias 4 2 Ajuste de la fecha y hora 5 Medici n de la presi n sangu nea 5 1 Colocaci n del brazalete 5 2 Postura correcta 5 3 Selecci n de memoria 5 4 Para hacer una medici n 5 4 1 Notas generales 5 4 2 Toma de la medici n 6 Evaluaci n de resultados 6 1 S mbolo de ritmo cardiaco irregular 6 2 Indicador de categor a de riesgo on
38. e Energ a 4 bater as AAA de 1 5 V alcalinas tipo LR03 Duraci n de la aprox para 250 mediciones dependiendo del bater a nivel de presi n sangu nea o presi n de inflado Accesorios bolsa de almacenamiento Instructivo de uso 4 bater as AAA Equipo energizado internamente X Parte aplicada tipo BF IPXO No es adecuado para usarse en presencia de mezclas anest sicas inflamables con aire u ox geno u xido nitroso Funcionamiento continuo con carga de poco tiempo ADVERTENCIA Lea la informaci n de seguridad y todas las instrucciones para evitar lesiones graves X Deseche el producto usado en el centro de reciclaje de acuerdo con las regulacio nes locales Clasificaci n BF Clave de los simbolos parte de aplicaci n tipo BF E 36 Apagado auto m tico 1 minuto despu s de la operaci n del ltimo bot n Estas especificaciones est n sujetas a cambio sin previo aviso con fines de mejora e Esta unidad est fabricada conforme a la norma internacional IEC 60601 1 2 y est sujeta a precau ciones especiales con respecto a la compatibilidad electromagn tica EMC Tenga en cuenta que los sistemas de comunicaci n HF port tiles y m viles pueden interferir con este instrumento Para m s detalles llame al servicio al cliente e Las mediciones de presi n sangu nea que se tomen con este dis positivo equivalen a las que se obtiene un observador entrenado con un m to
39. e display with all digits lighting up the monitor will automatically inflate During inflation the device already determines measured values used to estimate the required inflation pressure Note This monitor will re inflate automatically if the system detects that your body requires more pressure for measurement Then the pressure in the cuff is slowly released the heart rate icon is flashing and the heart rate is measured As the cuff deflates decreasing numbers appear on the display When the measurement has been completed the cuff will deflate entirely The heart rate the systolic and the diastolic blood pres sure with RISK CATEGORY INDICATOR bar are displayed 12 e You can interrupt measurement at any time by pressing the button The cuff will deflate immediately after the button is pressed e The E icon appears if it has not been possible to perform the measurement properly Observe the section in these instructions on error messages troubleshooting and repeat the measure ment The device switches off automatically after 1 minute Wait at least 5 minutes before taking another measurement 6 Evaluating results A VVARNING This product does not and is not intended to provide a medical diagnosis Measurement results are for reference only Selfdiag nosis and treatment e g regarding medication using measured results represent a risk for your health Always consult with a li censed physician for det
40. e in connection with any products or parts thereof which are repaired replaced altered or modified without the prior explicitly written consent of the warrantor This warranty gives you specific legal rights and you may also have other rights which may vary from state to state Made in China Questions or comments Call toll free 1 800 536 0366 Distributed by CVS Pharmacy Inc One CVS Drive Woonsocket RI 02895 O 2011 CVS pharmacy www cvs com 1 800 shop CVS 19 4 CVS Quality Money Back Guarantee ESPANOL NOTAS IMPORTANTES DE SEGURIDAD Signos y simbolos Los siguientes signos aparecen en la secci n Seguridad p ginas 20 21 22 y 23 y en este manual en las p ginas 26 27 28 31 32 33 34 y 36 LEA CON ATENCI N TODO ESTE MANUAL LA SECCI N DE SEGURIDAD Y TODAS LAS INSTRUCCIONES Y ADVERTENCIAS ANTES DE USAR ESTE PRODUCTO SIGA TODAS LAS INSTRUC CIONES Y ADVERTENCIAS DE SEGURIDAD PARA EVITAR Sl TUACIONES PELIGROSAS Y PARA USAR CORRECTAMENTE ESTE PRODUCTO ADVER TENCIA ADVERTENCIA indica una situaci n peligrosa que si no se evita podr a causar la muerte o una lesi n seria PRECAUCI N indica una situaci n peligrosa que si no se evita podr a causar una lesi n menor o moderada AVISO se refiere a pr cticas que no est n relacionadas con lesiones como es el caso de da os al producto o da os materiales A ADVERTENCIA e Consulte a su m dico antes de comenzar a medir su pres
41. e siempre las bater as de acuerdo con las normas locales correspondientes No deseche las bater as junto con la basura dom stica normal Nunca trate de reparar abrir o desarmar esta unidad incluyen do el brazalete y el accesorio opcional ni de ajustarla usted mismo Podr a da ar la unidad e impedir su funcionamiento correcto Si la unidad requiere reparaci n llame a nuestro ser vicio al cliente Vea en la garant a la informaci n de contacto de servicio Antes de presentar cualquier queja revise las bater as y reempl celas si es necesario e Los cambios o modificaciones en el dispositivo anularan la garant a del usuario e No permita que caiga ni introduzca ning n objeto por ninguna abertura o manguera Esto puede da ar la unidad e No presione los botones con fuerza excesiva o con objetos punzantes Para mantener su tensi metro digital en la mejor condici n y prote gerlo contra da os siga estas instrucciones e Limpie su dispositivo y brazalete con cuidado solamente con una tela suave ligeramente humedecida y s quelo inmediatamente con una tela seca y suave No lo presione e Al almacenar el dispositivo aseg rese de que no se pongan ob jetos pesados sobre l e No doble el brazalete ni el tubo con mucha fuerza El tubo del brazalete no deber tener torceduras mant ngalo alejado de bordes afilados 34 e Si la unidad se guarda cerca de la temperatura de congelaci n deje que llegue a temperatura amb
42. e user number e If you wish to change the user memory see Select memory 8 Care maintenance and storing the instrument A VVARNING e Do not use any cuffs tubes parts and accessories other than those explicitly recommended by the manufacturer for use with this product Parts and accessories not approved for use with the device may cause damage to your health and to the product A CAUTION Do not disassemble the unit it may result in injuries NOTICE e The blood pressure monitor is made up of precision electronic components Accuracy of readings and the instrument s ser vice life depend on careful handling Protect the unit against hard knocks e g dropping the unit moisture vvater dirt dust chemicals extreme hot or cold temperatures major temper ature fluctuations direct exposure to sunlight and heat sources which are too close e g stoves heating radiators This may damage the unit The device must be stored in the specified ambient conditions Please see section 8 Care maintenance and storing the instrument and section 11 Technical Speci fications for details Do not use any aggressive solvents cleaning agents detergents solvents or any other strong chemicals to clean the device e Never immerse and or spill water or any other liquid onto the monitor or any components otherwise liquid will enter it and cause damage Do not wash the unit in a washing machine dish washer or
43. echo de hacer sustituciones del producto en lugar de repararlo o reemplazarlo Para servicio de garant a llame a nuestro departamento de ser vicio al cliente al tel fono 1 800 536 0366 para proporcionar una descripci n del problema Si se considera que el problema est dentro del alcance de la garant a limitada de por vida se le pedir que env e el producto a expensas suyas en su empaque original con el comprobante de compra y su nombre domicilio y n mero telef nico Si se estima que el problema no est cubierto por la garant a limitada de por vida le enviaremos una cotizaci n para la reparaci n o reemplazo as como el costo del env o Esta garant a no cubre da os causados por mal uso o abuso acci dente conexi n de accesorios no autorizados alteraci n del pro ducto instalaci n incorrecta aplicaci n err nea falta de cuidado razonable con respecto al producto reparaciones o modificaciones no autorizadas uso indebido de alimentaci n o energ a el ctrica bater as usadas gastadas desgaste normal falta de potencia producto dejado caer mal funcionamiento o da o de una parte operativa por no cumplir con las instrucciones de uso o de propor cionar el mantenimiento recomendado por el fabricante da o en el transporte robo negligencia vandalismo condiciones ambientales p rdida del uso durante el periodo en que el producto est en una instalaci n de reparaci n o en espera de partes o reparaci n por ot
44. ediciones de presi n sangu nea pueden causar marcas temporales en la piel en el lugar donde se coloc el brazalete Este es especialmente el caso cuando se usa repetidamente en pacientes hipert nicos y en pacientes con ritmo cardiaco d bil En algunos casos poco comunes una marca puede persistir varios d as Consulte a su m dico respecto a estos riesgos espec ficos de presi n del brazalete en su caso espec fico e Por razones higi nicas el brazalete es exclusivamente de uso personal 5 1 Colocaci n del brazalete Nota Coloque siempre el brazalete correctamente sobre el brazo al nivel del coraz n de acuerdo con las siguientes instrucciones Ajuste el brazalete alrededor de su brazo izquierdo sin ropa No ponga el brazalete sobre sopa gruesa como una chaqueta o la manga de un su ter ya que el ten si metro no podr hacer una medici n adecuada La circulaci n de la sangre en el brazo no debera estar restringida por ropa apretada ni otros obietos El brazalete debe colocarse sobre el brazo de manera que el borde inferior quede aproximadamente de 0 8 a 1 2 2 a 3 cm por arriba de la flexi n del codo y por arriba de la arteria El tubo debera estar alineado con el centro de la palma Ahora coloque el extremo libre del braza lete ajustado pero no demasiado apreta do alrededor del brazo y f jelo con la cinta velcro El brazalete deber estar suficien temente ajustado para permitir meter dos
45. embarazadas 27 Debido a su afecci n el m todo de medici n oscilom trica puede dar lecturas incorrectas Esto representa un riesgo para su salud puesto que los valores se pueden interpretar inco rrectamente Consulte siempre a un m dico para determinar qu es lo m s adecuado para usted Nunca trate de adaptar o enchufar este dispositivo a la l nea de CA Este dispositivo funciona con bater as Este producto no tiene el prop sito de ser un sustituto del consejo de un m dico o un profesional de la medicina Este producto no es para sustituir los ex menes m dicos peri dicos Comun quese con su m dico para pedir informaci n espec fica sobre su presi n sangu nea Las mujeres que se sometieron a una operaci n para extirpar una mama o un nodo linf tico axilar deber n consultar a un m dico antes de comenzar a hacer mediciones de presi n sangu nea Antes de usarlo aseg rese de que el tensi metro no est da ado En caso de duda no use la unidad y llame al servicio al cliente al tel fono 1 800 536 0366 Este dispositivo es solo para uso personal no comercial y en adultos para medir la presi n sangu nea y el ritmo cardiaco No use el producto para ning n otro prop sito Este producto no es para usar en un hospital consultorio m dico o ning n otro centro de atenci n m dica e La unidad se debe usar de conformidad con las condiciones ambientales especificadas de otro modo la exactitud de
46. ermination of appropriate medication and dosage thereof Follow the instructions of your physician or licensed healthcare provider If you have or suspect that you have a medical problem promptly consult your physician f you have an emergency please call 911 immediately e Only a physician or a trained health care professional who is fam iliar with your medical history is able to accurately interpret your blood pressure measurements Consult your physician before starting blood pressure monitoring Please note that technically related measuring tolerances are possible Please see section 11 Technical Specifications for details e If you notice abnormal or suspicious variations in blood pres sure measurements consult your physician immediately Note A single measurement does not provide an accurate indica tion of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency 6 1 Irregular heartbeat symbol A VVARNING e The irregular heartbeat function does not replace a cardiac examination but may help to detect potential heart rate ir regularities at an early stage Alvvays consult your physician to determine vvhat vvill be suitable for you e The irregular heartbeat function is not designed for diagnos ing or treating an arrhythmic disorder Arrhythmia can only be ascertained by a licensed physici
47. fectan a la presi n sangu nea es raro obtener mediciones id nticas de presi n sangu nea incluso cuando se toman con intervalo de pocos minutos Hable con su m dico para determinar qu est afectando a su presi n sangu nea y qu variaci n podr a considerarse normal en su caso e La exactitud de cualquier medici n de la presi n sanguinea con este dispositivo puede verse afectada por numerosas causas Algunas pueden evitarse y algunas se tienen que aceptar en el momento de la medici n Hable con su m dico sobre las posibles causas que afectan a su presi n sangu nea e No infle el brazalete a menos que est envuelto en el brazo e Al hacer mediciones repetidas aseg rese de seleccionar al mismo usuario de modo que las mediciones se registren en la memoria adecuada Si no se presiona ning n bot n durante un minuto la funci n de apagado autom tico apaga la unidad para conservar las bate r as No toque la unidad el tubo o el brazalete ni presione ning n bot n cuando la medici n est en curso excepto para detenerla Hacerlo puede causar lecturas incorrectas 30 5 4 2 Toma de la medici n Nota Si usa la unidad por primera vez retire la pel cula protectora de la pantalla Ponga el brazalete alrededor de su brazo izquierdo descubierto en la forma descrita arriba y asuma la posici n en que desea hacer la medici n e Con los botones seleccione la memoria de usuario 1 o 2 Comience el proce
48. ferent people age groups etc Please consult your physician for proper diagnosis After each measurement is completed the bar graph in the display and the scale on the unit indicate the range of the blood pressure which has been recorded Check up the comparison chart above to see what stage your measuring result fits in Note When a person s systolic and diastolic pressures fall into different categories the higher category should apply e g systolic rate 181 amp diastolic rate 99 gt Red category Stage 2 Hypertension e g systolic rate 110 8 diastolic rate 95 gt Red category Stage 1 Hypertension For adults 18 and older who are not on medicine for high blood pressure are not having a short term serious illness and do not have other conditions such as diabetes and kidney disease To determine category of risk when systolic and diastolic readings fall into two areas use the higher of the two numbers for classification There is an exception to the above definition of high blood pressure for people with diabetes and chronic kidney disease A blood pres 14 sure of 130 80 mmHg or higher is considered high blood pressure for those individuals Note The above table is not exact for classification of blood pressure and it s intended to be used as a guide in understanding non invasive blood pressure measurements Usually this is not a cause for concern however we recommend you consult with your physician for proper
49. i n sangu nea PRECAU CI N AVISO e Lea y comprenda todas las instrucciones y advertencias antes de usar este dispositivo Al igual que con cualquier dispositivo oscilom trico de me dici n de la presi n sangu nea algunas afecciones pueden afectar la exactitud de la medici n entre otras trastorno del ritmo cardiaco presi n sangu nea muy baja pacientes de estado de shock pacientes con perfusi n sangu nea muy baja diabetes anormalidades en vasos sangu neos personas con implantes el ctricos como marcapasos mujeres embarazadas Debido a su afecci n el m todo de medici n oscilom trica puede dar lecturas incorrectas Esto representa un riesgo para su salud puesto que los valores se pueden interpretar inco rrectamente Consulte siempre a un m dico para determinar qu es lo m s adecuado para usted Nunca trate de adaptar o enchufar este dispositivo a la l nea de CA Este dispositivo funciona con bater as Este producto no tiene el prop sito de hacer un diagn stico m dico Las mediciones son solo como referencia El autodiag n stico y el tratamiento por ejemplo respecto a medicamentos basados en los resultados de las mediciones representan un riesgo para su salud Consulte siempre con un m dico pa ra determinar el medicamento adecuado y su dosis Siga las instrucciones de su m dico o proveedor de atenci n m dica autorizado Si tiene un problema m dico o s
50. iente antes de usarla e Guarde siempre la unidad en la bolsa despu s de usarla Esta unidad no cumple sus especificaciones de desempe o si se guarda o usa fuera de los rangos de temperatura y humedad indicados vea la secci n 11 Especificaciones t cnicas e Use la unidad de acuerdo con las instrucciones de este ma nual 9 Mensajes de error y soluci n de problemas Si se presenta alguna anomal a durante el uso revise los puntos siguientes Pantalla de 1 Causas posibles Correcci n error s ntomas EE La presi n es menor de Repita la medici n 40 mm de Hg o el ritmo Aseg rese de que el cardiaco es menor de brazalete est colocado 4 latidos correctamente el tubo El El brazalete se infla por _ del brazalete est in m s de 25 segundos sertado correctamente El tubo del brazalete Y 141117 ia inserlad i hablar Reinstale las esta ado correcta bater as si es necesario mente o bien reempl celas E2 La presi n de inflado es mayor de 300 mm de Hg ES La presi n sangu nea es inusualmente alta o baja Usted se mueve o habla durante la medici n ade m s de E3 aparece el cono de ritmo cardiaco Wa en la pantalla Pantalla de Causas posibles Correcci n error s ntomas La unidad no Las bater as se agotaron Reemplace las bater as se enciende Las polaridades de las Vuelva a insertar las cuando se bater
51. ing e This product is not intended to serve as a substitute for the advice of a physician or medical professional This product is not intended to substitute for regular medical checkups Con tact your physician for specific information about your blood pressure e Please note that technically related measuring tolerances are possible Please see section 11 Technical Specifications for details e Any cuff related blood pressure measurement in high repetition rates can lead to severe measurement side effects e g a nerval compression with temporary arm hand paralysis the release of an arterial or venous thrombus which can cause a life threatening situation Please contact your physician about the specific risks of cuff pressure in your specific case e The irregular heartbeat function does not replace a cardiac examination but may help to detect potential heart rate ir regularities at an early stage Always consult your physician to determine what will be suitable for you e The irregular heartbeat function is not designed for diagnos ing or treating an arrhythmic disorder Arrhythmia can only be ascertained by a licensed physician The Risk Category Indicator chart is not intended to replace a medical diagnosis This chart is only a reference for different classifications of blood pressure e If you notice abnormal or suspicious variations in blood pres sure measurements consult your physician immediate
52. instrumento y la secci n 11 Especificaciones t cnicas para m s detalles No se envuelva el brazalete en ninguna parte del cuerpo que no sea su brazo izquierdo El mal uso representa un riesgo para su salud Use este monitor solo en humanos La ingesti n de bater as o l quido de bater as puede ser su mamente peligrosa Mantenga las bater as y la unidad fuera del alcance de los ni os y de las personas con discapacidad Si alguien ingiere una bater a o el fluido de la bater a llame inmediatamente al 911 e Las bater as no deben cargarse ni reactivarse por ning n otro medio Las bater as pueden explotar e Las bater as no deben abrirse arrojarse al fuego ni conectarse en corto circuito Las bater as pueden explotar En caso de que el fluido de bater a se derrame y haga contacto con sus ojos o piel enjuague de inmediato con agua limpia en abundancia Llame de inmediato al 911 A ADVERTENCIA e Este producto no es para usarse en ni por ni os ni os pe que os infantes ni en personas que no puedan expresar su consentimiento es decir personas con trastornos mentales o similares Consulte a su m dico para conocer m todos alter nos para medir la presi n sangu nea de un ni o Este producto no es un juguete Mant ngalo lejos del alcance de los ni os e infantes Mantenga el producto fuera del alcance de las mascotas Los materiales de embalaje son un riesgo mortal para los ni os y pueden c
53. inutos entre cada medici n y no hablar ni moverse durante la medici n Si el cono sigue apareciendo en lecturas subsecuentes le recomenda mos que consulte a su m dico para determinar si eso es motivo de inquietud No trate de interpretar las lecturas ni tratar una afecci n usted mismo Siga la orientaci n de un profesional de la salud Si se le presenta una emergencia llame al 911 de inmediato 6 2 Indicador de categor a de riesgo ADVERTENCIA e La tabla Indicador de categor a de riesgo no tiene el prop sito de reemplazar el diagn stico m dico Esta tabla es solo una refe rencia para diferentes clasificaciones de la presi n sangu nea Este dispositivo tiene un indicador de categor a de riesgo que clasi fica las mediciones de presi n sangu nea en cuatro etapas Normal Prehipertensi n Hipertensi n en etapa 1 e Hipertensi n en etapa 2 con base en los est ndares de presi n del Departamento de Salud y Servicios Humanos de los Estados Unidos y de los Institutos Na cionales de Salud Adem s para la salud suya y de sus seres que ridos nosotros clasificamos las cuatro etapas en rangos num ricos que clasifican s ntomas de hipertensi n con m s claridad Adem s para su comodidad y facilidad de lectura usamos cuatro colores correspondientes para representar los resultados de las mediciones Consulte la tabla de comparaci n siguiente para m s detalles Etapas de niveles de Sist
54. larities Re insert the batteries the button have been positioned in the correct position is pushed incorrectly The unit is defective Contact customer Service See warranty section h Batteries have run down Replace the batteries Measurement Blood pressure varies Review the section values appear constantly Many factors 5 Measuring Blood too high or too including stress time of Pressure low day how you wrap the cuff etc may affect your blood pressure Note If EP appears on the display please contact our customer service See warranty section Note If the unit still does not work contact customer service at 1 800 536 0366 10 FCC Statement This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc tions may cause harmful interference to radio or television receptions which can be determined by turning the equipment off and on The user is encouraged to try to correct the interference by one or more of the follovving measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the
55. letely When h t appears in the display please change the batteries Leaking batteries may damage the device If you do not intend to use the unit for longer periods remove the batteries from the battery compartment before placing the device in storage e Never attempt to repair open and or disassemble the unit including arm cuff and optional accessory or adjust it your self This may damage the unit and impair the functions If you need to have the unit repaired please contact our customer service Please see warranty for service contact Before sub mitting any complaint first check the batteries and replace them if necessary e Changes or modifications to the device will nullify the user warranty Do not drop or insert any object into any opening or hose This may damage the unit Do not press the buttons with excessive force or with pointed objects Contents IMPORTANT SAFETY NOTES A WARNING A CAUTION 1 Getting to know your instrument 2 Package Contents 3 Device description 3 2 Display Explanations 4 Prepare measurement 4 1 Inserting Replacing batteries 4 2 Setting date and time 5 Measuring blood pressure 5 1 Positioning cuff 5 2 Correct posture 5 3 Select memory 5 4 Taking Measurement 5 4 1 General Notes 5 4 2 Taking Measurement 6 Evaluating results 6 1 Irregular heartbeat symbol 6 2 Risk Category Indicator 7 Saving retrieving and
56. ly Women who underwent a breast or axillar lymph node removal operation should consult a physician or licensed healthcare provider before starting blood pressure measurements e Prior to use you have to ensure that the blood pressure monitor is free of damage If in doubt do not use the unit and contact customer service at 1 800 536 0366 This device is intended only for personal non commercial adult use in measuring blood pressure and heart rate Do not use the product for any other purpose This product is not intended for use in a hospital physician s office or any other health care facility The unit must be used in accordance to the specified ambient conditions otherwise the accuracy of readings might be affect ed See section 8 Care maintenance and storing the instru ment and section 11 Technical Specifications for details Do not wrap the cuff around body parts other than your upper left arm Misuse represents a risk to your health e Use this monitor only on humans e Swallowing batteries and or battery fluid can be extremely dangerous Keep the batteries and the unit out of the reach of children and disabled persons Should any person swallow a battery and or battery fluid please call 911 immediately Batteries should not be charged or reactivated by any other means The batteries may explode Batteries should not be taken apart throvvn in the fire or short circuited The batteries may
57. mo cardiaco en una etapa temprana Consulte siempre a un m dico para determinar qu es lo m s adecuado para usted e La funci n ritmo cardiaco irregular no est dise ada para diag nosticar ni tratar una arritmia Solo un m dico puede diagnosticar la arritmia Este s mbolo Cn indica que se detectaron ciertas irregularidades del ritmo cardiaco durante la medici n En general un ritmo cardiaco irregular se define como un ritmo que es mas de un 25 mas lento o un 25 mas rapido que el ritmo promedio detectado mientras el monitor esta midiendo la presi n sanguinea sistdlica y diast lica Para filtrar la condici n inestable de usuario y evitar afectar la de tecci n del ritmo cardiaco por cualquier movimiento sacudida o al hablar al principio de la medici n el m todo de promediar intervalos de ritmos cardiacos del dispositivo se calcula con los tres pulsos del ritmo cardiaco apropiados que se detectaron al principio de la medici n y que es diferente a una promediaci n matematica estricta de todos los intervalos registrados Al menos 3 latidos con al menos un 25 de diferencia del intervalo del ritmo cardiaco promedio generar n el icono IHB en la pantalla NOTA e Hablar moverse sacudirse o un ritmo cardiaco irregular durante la medici n pueden resultar en la aparici n de este s mbolo Repita la medici n si el cono parpadeando se muestra despu s de la medici n Tenga en cuenta que debe descansar al menos 5 m
58. n de memoria Encienda el tensi metro con el bot n Seleccione el espacio de memoria que requiera presionando el bot n de funci n Hay dos memorias 60 espacios de memoria cada una para guardar los resultados de las pruebas de dos usuarios diferentes en forma sepa rada o bien en la ma ana y en la tarde en forma independiente 5 4 Para hacer una medici n 5 4 1 Notas generales Para lograr un monitoreo y referencia fiables de la presi n san gu nea se recomienda mantener registros a largo plazo e Para minimizar variaciones en las mediciones debido a actividad f sica descanse al menos 5 minutos antes de medirse la presi n sangu nea o 15 minutos despu s de una actividad intensa No de ber estar f sicamente cansado ni agotado al hacer la medici n e Para obtener la presi n sanguinea en condici n de reposo evite comer tomar alcohol y bebidas con cafe na fumar hacer ejerci 29 cio y ba arse durante al menos 30 minutos antes de hacer una medici n e El estr s eleva la presi n sangu nea e Haga las mediciones en un entorno tranquilo y relajado a tempe ratura ambiente e Espere siempre al menos 5 minutos entre mediciones para dejar que la circulaci n sangu nea en el brazo vuelva a la normalidad Es posible que necesite aumentar el tiempo de espera dependien do de sus caracter sticas fisiol gicas individuales Debido a los cambios fisiol gicos normales y los numerosos factores externos que a
59. ncia electromagn tica Evite los campos el ctricos o electromagn ticos fuertes cercanos al dispositivo como tel fonos celulares y hornos de microondas mientras est en operaci n ya que se pueden producir mediciones inexactas Para prevenir esa interferencia use la unidad a una distancia suficiente de estos dispositivos o ap guelos e No mida su presi n sanguinea mientras opera un veh culo o es t en una situaci n que exija toda su atenci n A PRECAUCI N e El dispositivo no se deber usar si hay lesiones o heridas en su brazo o cuando tiene un cat ter insertado Usarlo as puede producir lesiones e Retire toda clase de joyas y objetos similares del brazo antes de hacer una medici n Eso podr a causar moretones No ponga el brazalete sobre ropa gruesa como una chaqueta ola manga de un su ter ya que el tensi metro no podr hacer una medici n adecuada y existe un alto riesgo de provocar un hematoma o dejar marcas en la piel durante el curso de la medici n En el caso de que el brazalete no deje de inflarse interrumpa la medici n al presionar el bot n ON OFF y abra el brazalete de inmediato Si una bater a presenta fuga no toque el l quido Evite el con tacto con la piel use guantes protectores y limpie el compar timiento de la bater a con una tela seca No desarme la unidad esto puede causar lesiones e Al aplicar el brazalete aseg rese de que no haya arrugas en l Eso podr a ca
60. ntes medidas Reorientar o cambiar de lugar la antena receptora e Aumentar la distancia entre el equipo y el receptor e Conectar el equipo en una toma o circuito diferente a donde est conectado el receptor Consultar a un distribuidor o t cnico con experiencia en radio y televisi n 11 Especificaciones t cnicas N de modelo BM 35 M todo de medici n de presi n sangu nea oscilom trica no medici n invasiva en el brazo Rango de rango de presi n del brazalete 0 300 mm de Hg medici n rango de presi n sangu nea 40 280 mm de Hg ritmo cardiaco 40 199 latidos minuto sist lica 3 mm de Hg diast lica 3 mm de Hg Exactitud de la lectura ritmo cardiaco 5 del valor mostrado Incertidumbre de desviaci n est ndar permisible m xima seg n la medici n las pruebas cl nicas sist lica 8 mm de Hg diast lica 8 mm de Hg Grupos de 2 x 60 espacios de memoria 120 de memoria memoria total Dimensiones de la L 5 3 x An 4 1 x Al 2 1 unidad L 135 mm x An 105 mm x Al 53 mm Peso de la unidad aproximado 0 48 lb 217 g 35 Tama o de brazalete circunferencia del brazo aproximada 9 13 23 33 cm Nota brazalete grande 13 a 17 33 a 43 cm que se puede obtener a trav s del servicio al cliente 50 a 104 F 10 a 40 C 15 a 90 de HR Temperatura de operaci n Temperatura de almacenamiento y 4 a 158 F 20 a 70 C lt 90 HR transport
61. od pressure monitor with bat teries Note that it is only possible to save data when your blood pressure monitor is receiving power As soon as the batteries are dead date and time on the blood pressure monitor are lost Remove the battery cover from the back of the monitor Clean the battery contacts and those of the device prior to installation with a soft dry cloth e Insert or replace only four 1 5 V AAA alkaline batteries Make absolutely NO sure that you insert them with the cor rect polarity as indicated see the diagram inside the battery compartment Do not use other types of batteries e Replace the battery cover carefully If the battery change h 1 is continuously illuminated measure ment is no longer possible and you must replace all the batteries Once batteries have been removed from the device the date and time must be reset Memories if any will not be deleted during battery replacement 4 2 Setting date and time t is vital to set the date and time This is the only way that measure ments can be saved and recalled with the correct date and time The time is shown in 12 hour format 4 x AAA LRO3 1 5 V Proceed as follows to set the date and time e Switch on the blood pressure monitor with the button e Press the function key for over 5 seconds The month starts flashing Change the month by pressing the button Each press will increase the number by one
62. onditions can affect the measurement ac curacy among others disorder of the cardiac rhythm very low blood pressure patients in shock patients with very low blood perfusion diabetes vessel anomalies people with electrical implants such as a cardiac pace maker women who are pregnant Due to their condition the oscillometric measurement method can produce incorrect readings This represents a risk for your health since values may be interpreted incorrectly Always con sult your physician to determine what will be suitable for you Never try to adapt or plug this device to the AC line This device is battery powered This product does not and is not intended to provide a medical diagnosis Measurement results are for reference only Self diagnosis and treatment e g regarding medication using measured results represent a risk for your health Always con sult with a licensed physician for determination of appropriate medication and dosage thereof Follow the instructions of your physician or licensed healthcare provider If you have or suspect that you have a medical problem promptly consult your phys ician If you have an emergency please call 911 immediately A VVARNING e Only a physician or a trained health care professional who is familiar with your medical history is able to accurately interpret your blood pressure measurements Consult your physician before starting blood pressure monitor
63. ones como diabetes o enfermedad renal Para determinar la categor a de riesgo cuando las lecturas sist lica y diast lica corresponden a dos reas use el n mero m s alto de los dos para clasificaci n Hay una excepci n a la definici n anterior de presi n sangu nea alta para las personas con diabetes y enfermedad renal cr nica Una presi n sangu nea de 130 80 mm de Hg o mayor se considera presi n sangu nea alta para esas personas Nota La tabla anterior no es exacta para clasificaci n de la presi n san gu nea y tiene el prop sito de usarse como gu a para entender mediciones de presi n sangu nea no invasivas Generalmente esto no es una causa de preocupaci n sin embargo le recomendamos que consulte a un m dico para que le realice un diagn stico correcto o solicite consejo m dico Tenga en cuenta que el dispositivo no es adecuado para diagnosticar hipertensi n y solo es para referencia del usuario en la medici n de la presi n sanguinea 7 C mo guardar recuperar y borrar resultados e Los resultados de cada medici n correcta se guardan juntos con la fecha y hora Cada usuario puede guardar hasta 60 lecturas de datos medidos Al tener m s de 60 lecturas de datos medidos las lecturas m s antiguas de datos medidos se eliminan Seleccione la memoria de usuario que desea al presionar el bot n MEM y el bot n Presione el bot n MEM nuevamente para mostrar el promedio de las 3 ltimas mediciones en
64. ospecha tenerlo consulte inmediatamente a su m dico Si se le presenta una emergencia llame al 911 de inmediato A ADVERTENCIA e Solo un m dico o un profesional capacitado de salud que est familiarizado con su historial m dico podr interpretar con exac titud sus mediciones de presi n sangu nea Consulte a su m di co antes de comenzar un monitoreo de la presi n sangu nea e Este producto no tiene el prop sito de ser un sustituto del consejo de un m dico o un profesional de la medicina Este producto no es para sustituir los ex menes m dicos peri dicos Comun quese con su m dico para pedir informaci n espec fica sobre su presi n sangu nea Observe que son posibles tolerancias de medici n t cnicamen te relacionadas Vea la secci n 11 Especificaciones t cnicas para m s detalles e Cualquier medici n de la presi n sangu nea relacionada con un brazalete cuando se usa repetidamente puede resultar en efectos secundarios serios de la medici n por ejemplo compresi n de nervios con par lisis temporal del brazo o la mano liberaci n de un trombo arterial o venoso que puede causar una situaci n que pone en riesgo la vida Consulte a su m dico con respecto a los riesgos espec ficos de presi n del brazalete en su caso espec fico e La funci n ritmo cardiaco irregular no reemplaza un examen cardiaco pero puede ayudar a detectar irregularidades poten ciales en el ritmo cardiaco en un
65. place siempre todas las bater as al mismo tiempo y use bater as del mismo tipo Reemplace las bater as con poca carga antes de que se des carguen completamente Cambie las bater as cuando aparezca ten la pantalla e Las bater as con fuga pueden da ar el dispositivo Si no va a usar la unidad durante un periodo largo retire las bater as de su compartimiento antes de guardar el dispositivo Nota El tensi metro solo funciona con bater as Observe que so lo es posible guardar datos cuando el tensi metro est recibiendo energ a En cuanto las bater as se descargan se pierden del ten si metro la fecha y hora e Retire la tapa de las bater as de la 4 x AAA LR03 1 5 V parte posterior del monitor e Limpie los contactos de las bater as O y los del dispositivo antes de la ins talaci n con una tela suave y seca Inserte o reemplace solo con cuatro bater as alcalinas AAA de 1 5 V NO O Aseg rese bien de insertarlas con la polaridad correcta seg n lo in dicado vea el diagrama dentro del compartimiento de bater as No use otros tipos de bater as e Reinstale la tapa de las bater as con cuidado Si el cambio de bater a h est iluminado permanentemente no es posible hacer la medici n y se deben reemplazar las bater as Una vez que se hayan retirado las bater as del dispositivo la fecha y hora deben volver a ajustarse Las memorias si las hay no se borrar n durante el reemplazo de las
66. professional If you have an emergency call 911 immediately 6 2 Risk Category Indicator WARNING e The Risk Category Indicator chart is not intended to replace a medical diagnosis This chart is only a reference for different classifications of blood pressure This device is equipped with a Risk Category Indicator which clas sifies your blood pressure measurements into four stages Normal Pre hypertension Stage 1 Hypertension to Stage 2 Hypertension based on the blood pressure standards established by the U S De partment of Health and Human Services and the National Institutes of Health Besides for your and your loved ones health we further classify the four stages into numeral ranges which sorts out hyper tension symptoms more clearly Moreover for your convenience and readability we use four corresponding colors to represent your measuring result Refer to below comparison chart for details 13 Stages of Systolic Diastole Color Blood Pressure Levels mmHg mmHg 2180 2110 Red Stage 2 Hypertension H 60 179 100 109 Red Stage 1 Hypertension 140 159 190 99 Red Bu Benenson 130 139 185 89 Yellovv 120 129 80 84 Light Green Normal lt 120 lt 80 Dark Green Source U S department of Health and Human Services and the National Insti tutes of Health Note This standard classification however is a general guideline as an individual s blood pressure varies among dif
67. ra causa o cualquier condici n de otro tipo que est fuera del control del garante Esta garant a no es v lida si el producto se usa alguna vez en un ambiente comercial o de negocio La m xima responsabilidad del garante bajo esta garant a se limita al precio de compra pagado realmente por el cliente por el producto cubierto por la garant a seg n se confirme mediante prueba de compra independientemente de la cantidad de cualquier otro da o directo o indirecto que sufra el cliente Esta garant a es efectiva solamente si el producto se compra y usa en el pa s de compra del producto Un producto que requiere modi ficaciones o adaptaci n para permitirle funcionar en cualquier otro pa s que no es el pa s para el cual fue dise ado fabricado aproba do y o autorizado o la reparaci n de productos da ados debido a esas modificaciones no est n cubiertos por esta garant a LA GARANT A AQU PROPORCIONADA SER LA GARANT A NICA Y EXCLUSIVA CUALESQUIER GARANT AS OBLIGA CIONES O RESPONSABILIDADES IMPL CITAS INCLUYENDO PERO SIN LIMITARSE A LA GARANT A IMPL CITA DE COMER CIABILIDAD E IDONEIDAD PARA UN PROP SITO EN PARTI CULAR EST N LIMITADAS EN CUANTO A DURACI N A LA DURACI N DE ESTA GARANT A ESCRITA APLICABLE Algunos estados no permiten limitaciones acerca de la duraci n de una garant a impl cita de manera que las limitaciones anteriores podr an no ser aplicables para usted EN NING N CASO EL GARANTE SER
68. rcumference approx 9 13 23 33 cm Note large cuff 13 to 17 33 to 43 cm is available at customer service Operating 50 F to 104 F 10 C to 40 C Temperature 15 to 90 RH Key to symbols WARNING Read the safety information and all instructions to avoid serious injury application part Type BF K Discard the used product to the recyc ling collection point according to local regulations 1 minute after last button operation Auto shut off These specifications are subject to change without notice for pur pose of improvement e This unit is in line with the International Standard IEC 60601 1 2 and is subject to particular pre cautions with regard to electromagnetic compat ibility EMC Please note that portable and mobile 17 HF communication systems may interfere with this instrument For more details please contact customer service e Blood pressure measurements taken with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method and are within the accuracy limits prescribed by the American National Standard for Electronic or Automated Sphygmomanometers e t is recommended the performance should be checked every 5 years or after repair Please contact customer service 12 Warranty Limited Lifetime Warranty For Original Purchaser Your CVS pharmacy Blood Pressure Monitor Model BM35 ex cluding the cuff incl t
69. rias A ADVERTENCIA e La ingesti n de bater as o l quido de bater as puede ser su mamente peligrosa Mantenga las bater as y la unidad fuera del alcance de los ni os y de las personas con discapacidad Si alguien ingiere una bater a o el fluido de la bater a llame inmediatamente al 911 e Las bater as no deben cargarse ni reactivarse por ning n otro medio Las bater as pueden explotar e Las bater as no deben abrirse arrojarse al fuego ni conectarse en corto circuito Las bater as pueden explotar e En caso de que el fluido de bater a se derrame y haga contacto con sus ojos o piel enjuague de inmediato con agua limpia en abundancia Llame de inmediato al 911 A PRECAUCI N e Si una bater a presenta fuga no toque el l quido Evite el con tacto con la piel use guantes protectores y limpie el compar timiento de la bater a con una tela seca AVISO e Las bater as pueden contener toxinas nocivas para el medio ambiente Deseche siempre las bater as de acuerdo con las normas locales correspondientes No deseche las bater as junto con la basura dom stica normal Use siempre el tama o y tipo de bater a indicados Si usa otras bater as da ar el dispositivo e Nunca use diferentes tipos de bater as marcas de bater as o bater as de diferente capacidad Esto puede da ar la unidad De preferencia use bater as alcalinas 26 Nunca use bater as recargables Esto puede da ar la unidad Reem
70. shipping fees This warranty does not cover damage caused by misuse or abuse accident the attachment of unauthorized accessories alteration to the product improper installation misapplication lack of rea sonable care with respect to the product unauthorized repairs or modifications improper use of electrical power supply old worn batteries normal wear loss of power dropped product malfunction or damage of an operating part as a result of failure to comply with instructions for use or to provide manufacturer s recommended maintenance transit damage theft neglect vandalism or environ mental conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other conditions whatsoever that are beyond the control of the warrantor This warranty is void if the product is ever used in a commercial or business environment The maximum liability of the warrantor under this warranty is limited to the purchase price actually paid by the customer for the product covered by the warranty as confirmed by proof of purchase regardless of the amount of any other direct or indirect damage suffered by the customer This warranty is effective only if the product is purchased and oper ated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufac tured
71. so de medici n al presionar el bot n Des pu s de verificar la pantalla con todos los d gitos encendidos el tensi metro se inflar autom ticamente Durante el inflado el dispositivo ya determina valores medidos que se usaron para estimar la presi n de inflado requerida Nota Este monitor se volver a inflar si el sistema detecta que su cuerpo requiere m s presi n para la medici n e Entonces la presi n en el brazalete se libera lentamente el cono de ritmo cardiaco parpadea y el ritmo cardiaco se mide Mientras se desinfla el brazalete aparecen n meros decrecientes en la pantalla Cuando la medici n ha finalizado el brazalete se desinfla com pletamente Se muestran el ritmo cardiaco la presi n sangu nea sist lica y diast lica con la barra INDICADOR DE CATEGOR A DE RIESGO Se puede interrumpir la medici n en cualquier momento al pre sionar el bot n Q El brazalete se desinflar inmediatamente despu s de presionar el bot n e Aparece cono E si no fue posible realizar la medici n correcta mente Observe en estas instrucciones la secci n sobre mensajes y soluci n de problemas y repita la medici n e El dispositivo se apaga autom ticamente despu s de 1 minuto Espere al menos 5 minutos antes de hacer otra medici n 6 Evaluaci n de resultados A ADVERTENCIA e Este producto no tiene el prop sito de hacer un diagn stico m di co Las mediciones son solo como referencia El autodi
72. surement e Please note that any muscle movement dur ing inflation or deflation can cause measurement error 11 5 3 Select memory Switch on the blood pressure monitor with the button Select the required memory space by pressing the function key You have two memories 60 memory spaces each in order to save the test results of 2 different users separately or alternatively save measurements in the morning and evening separately 5 4 Taking Measurement 5 4 1 General Notes e For reliable monitoring and reference of blood pressure keeping long term records is recommended To minimize measurement variations due to physical activity rest at least 5 minutes before measuring your blood pressure or 15 minutes after strenuous activity You should not be physically tired or exhausted while taking measurement In order to obtain a resting condition blood pressure avoid eating drinking alcohol and caffeinated beverages smoking exercising and bathing for at least 30 minutes before taking a measure ment Stress raises blood pressure Perform measurements in a quiet and relaxed environment at room temperature Always wait at least 5 minutes between measurements to allow the blood circulation in your arm to return to normal You may need to increase the wait time depending on your individual physiological characteristics Because of normal physiologic changes and the
73. surements Only use the device on adults who have the right upper arm circum ference for this instrument See section 11 Technical Specifi cations for suitable arm circumferences e Do not use any cuffs tubes parts and accessories other than those explicitly recommended by the manufacturer for use with this product Parts and accessories not approved for use with the device may cause damage to your health and to the product Electromagnetic interference Avoid strong electrical or elec tromagnetic fields in the direct vicinity of the device e g mo bile telephones microvvave ovens while it is in operation as inaccurate measurements may result To prevent such interfer ence use the unit at a sufficient distance from such devices or turn the devices off Do not measure your blood pressure while operating a vehicle or in any situation which requires your full attention A CAUTION The device should not be used when your arm has been wound ed injuried or when a catheter has been inserted Such use may result in injury Remove any kind of upper arm jewelry or the like before taking a measurement This could cause bruises Do not place the arm cuff over heavy clothing e g a jacket or sweater sleeve as the blood pressure monitor will not be able to take a proper measurement and there is an elevated danger of acquiring hematoma or skin marks during the course of the measurement e n case the cuff does not stop
74. ube and the batteries is warranted to be free from defects in materials and workmanship for the life of the product under normal conditions of intended use and service The cuff is warranted to be free from defects in materials and workmanship appearing within two years from date of purchase when the monitor is used in accordance with the instructions provided with the unit This warranty extends only to the original retail purchaser and does not extend to retailers or subsequent owners We will at our option repair or replace the CVS pharmacy Blood Pressure Monitor Model BM35 without additional charge for any part or parts covered by these written warranties No refunds will be given Repair or replacement is our only responsibility and your only remedy under this written warranty If replacement parts for defective materials are not available the warrantor reserves the right to make product substitutions in lieu of repair or replacement For warranty service contact our customer service department at 1 800 536 0366 to provide a description of the problem If the problem is deemed to be within the scope of the limited lifetime warranty you will be asked to mail the product at your costs in its original package with proof of purchase your name address and 18 phone number If the problem is not deemed to be within the scope of the limited lifetime warranty we will provide a quotation for repair respectively replacement and return
75. usar moretones A PRECAUCI N e No ejerza ninguna clase de presi n en la manguera durante la medici n por ejemplo no ponga los brazos ni otro objeto sobre la manguera Esto podr a causar mediciones incorrectas e Las mediciones de presi n sanguinea pueden causar marcas temporales en la piel en el lugar donde se coloc el brazalete Este es especialmente el caso cuando se usa repetidamente en pacientes hipert nicos y en pacientes con ritmo cardiaco d bil En algunos casos poco comunes una marca puede persistir varios d as Consulte a su m dico respecto a estos riesgos espec ficos de presi n del brazalete en su caso espec fico e Por razones higi nicas el brazalete es exclusivamente de uso personal AVISO e El tensi metro est integrado por componentes electr nicos de precisi n La precisi n de las lecturas y la vida de servicio del instrumento dependen del manejo cuidadoso Proteja esta unidad de golpes fuertes como dejarla caer humedad agua suciedad polvo qu micos temperaturas demasiado altas o ba jas cambios dr sticos de temperatura y exposici n a la luz solar directa y a fuentes de calor demasiado cercanas como estufas y radiadores de calor Esto puede da ar la unidad El dispositivo debe guardarse en las condiciones ambienta les especificadas Vea la secci n 8 Cuidado mantenimiento y almacenamiento del instrumento y la secci n 11 Especifi caciones t cnicas para m s detalles e