1. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION AND CONNECTIONS ARE TO BE MADE BY A QUALIFIED PERSON SAFETY GUIDELINES DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE FUEL OIL KEROSENE ETC DO NOT USE IN EXPLOSIVE ATMOSPHERES PUMP SHOULD BE USED WITH LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS DO NOT HANDLE PUMP WITH WET HANDS OR WHEN STANDING ON A WET OR DAMP SURFACE OR IN WATER THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND OR GROUNDING TYPE ATTACHMENT PLUG TO REDUCE THE RISK OF ELECTRICAL SHOCK BE CERTAIN THAT IT IS CONNECTED TO A PROPERLY GROUNDED GROUNDING TYPE RECEPTACLE IN ANY INSTALLATIONS WHERE PROPERTY DAMAGE AND OR Remove cardboard insert Retirez l encart du carton Retire la pieza de cart n Figure 1 PERSONAL INJURY MIGHT RESULT FROM AN INOPERATIVE OR LEAKING PUMP DUE TO POWER OUTAGES DISCHARGE LINE BLOCKAGE OR ANY OTHER REASON A BACKUP SYSTEM S AND OR ALARM SHOULD BE USED SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND WHEN INSTALLED FAILURE TO DO SO MAY CAUSE PIPING TO BREAK PUMP TO FAIL MOTOR BEARING FAILURES ETC INSTALLATION 1 Before installing pump allow air conditioner to cycle several times collecting condensate in a separate container to help flush any residual oils that may remain in the system 2 Carefully unpack the pump Remove the cardboard packing from the motor cover air slots Carefully slide the packing away from the pump This packin
2. examina lo cuidadosamente para determinar que no hay roto o da ado partes que pueden haber ocurrido durante el embarque Si el da o ha ocurrido hechoanotaci n y notificado la firma que usted compr la bomba desde Ellos ayudar n usted en el reemplazo o la reparaci n si requiri LEA DETENIDAMENTE LAS INSTRUCCIONES ANTES DE INTENTAR INSTALAR OPERAR O DAR MANTENIMIENTO A LA BOMBA LITTLE GIANT CONOZCA LAS LIMITACIONES APLICACIONES Y LOS PELIGROS POTENCIALES DE LA BOMBA PROTEJASE A SI MISMO Y A LOS DEMAS CUMPLIENDO TODAS LAS RECOMENDACIONES DE SEGURIDAD EL INCUMPLIMIENTO DE LAS INSTRUCCIONES PODRIA RESULTAR EN LESIONES PERSONALES Y O DA OS MATERIALES CONSERVE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS LA INSTALACI N Y LAS CONEXIONES DEBEN SER HECHAS POR UNA PERSONA CALIFICADA NORMAS DE SEGURIDAD NO USE LA UNIDAD PARA BOMBEAR LIQUIDOS INFLAMABLES NI EXPLOSIVOS TALES COMO GASOLINA FUELOIL QUEROSENO ETC NO USE LA UNIDAD EN AMBIENTES EXPLOSIVOS LA BOMBA SE DEBE USAR CON LIQUIDOS COMPATIBLES CON LOS MATERIALES DE LOS COMPONENTE DE LA BOMBA NO MANIPULE LA BOMBA CON LAS MANOS MOJADAS NI MIENTRAS SE ENCUENTRE EN UNA SUPERFICIE MOJADAS NI MIENTRAS SE ENCUENTRE EN UNA SUPERFICIE MOJADA O HUIMEDA O ENTRE EL AGUA ESTA BOMBA SE SUMINISTRA CON UN CONDUCTOR A TIERRA Y O UN ENCHUFE DE CONEXION DE TIPO DE CONEXION A TIERRA PARA REDUCIR EL RIESGO DE DESCARGA ELECTRICA ASEGURESE DE CONECTAR LA UNIDAD A UN RECEPTACULO DEL T
3. vend edor debe separar los art culos y retenerlos para que sean inspeccionados por un representante de Franklin Electric Co Inc o avisarle a la f brica de los detalles del problema para que la f brica disponga de las acciones necesarias y resuelva el reclamo de la garant a DESAUTORIZACION LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQUIER OTRA GARANTIA EXPRESA CUALQUIER GARANTIA IMPLICADA INCLUYENDO PERO NO LIMITADO A CUALQUIER GARANTIA IMPLICADA DE COMERCIALIZACION O APTITUD PARA PROPOSITO PARTICULAR EN LA MEDIDA EN QUE SE PUEDA APLICAR A UNA BOMBA QUEDARA LIMITADA EN DURACION A LOS PERIODOS DE GARANTIAS PROPORCIONADOS ANTERIORMENTE La garant a ser declarada NULA si se encuentran cualesquiera de las siguientes condiciones 1 El alojamiento sellado del motor abierto 2 El producto conectado a un voltaje que no es el indicado en la placa princi pal 3 El cable cortado a menos de tres pies 0 91 m 4 Se permiti que la bomba opere en seco env o de fluido cortado 5 La bomba empleada para hacer circular cualquier otra sustancia que no sea agua 6 Abuso del producto por parte del cliente Cualquier declaraci n oral acerca del producto hecha por el vendedor fabricante representantes o cualquiera de las partes no constituyen garant as el usuario no debe confiarse de ellas y no forman parte del contrato de compra venta La nica obligaci n del vendedor y del fabricante y el nico reme
4. A AI 154708 Check Valve 1 4 I D Tubing Soupape D arr t 1 4 I D Tube V lvula De 4 _ _ R _ _ _ R _ _ _ 4 _ 4 6 Retenci n Tuberia de I D 1 4 Check Valve 3 8 I D Tubing Soupape D arr t 3 8 I D Tube V lvula De 154715 Retenci n Tuberia de 1 D 3 8 1 1 1 1 1 1 1 1 1 1 1 1 6 154452 Float Arm Bras Du Flotteur Brazo Del Flotante 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Switch Holder ABS Natural Support De L interrupteur ABS Naturel Portador 7 199971 De Interruptor ABS Natural 1 1 1 1 1 1 1 1 1 1 1 1 951604 Wiring Harness Assy 115V 6 With Terminals Montage Faisceau De Cables 6 N 1 1 1 1 1 A 1 1 1 2 Pieds 15 Cm Avec Bornes Conjunto De Colector De Cables 6 Pies Con Bornes 951606 Wiring Harness Assy 230V 6 With Terminals Montage Faisceau De Cables 6 _ a E a k a 1 7 1 7 1 7 4 a 4 8 Pieds 1 8m Avec Bornes Conjunto De Colector De Cables 6 Pies Con Bornes 951089 Wiring Harness Assy 230V 6 With Terminals Montage Faisceau De C bles 6 4 A A A 7 A r A z A 1 1 A Pieds 1 8m Avec Bornes Conjunto De Colector De Cables 6 Pies Con Bornes 951088 Wiring Harness Assy 230V 3m With Terminals Ho5wv F Montage Faisceau De 7 N L 7 E L 7 7 t 1 Cables 3m Avec Bornes Conjunto De Colector De Cables 3 Metros Con Bornes 9 902414 Tapping Screw Vis Taraud e Tornillo Rosca Macho 8 18 x 5 8 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 950337 Switch e Commutateur Int
5. AR DES PROFESSIONNELS DIRECTIVES DE SECURITE AVERTISSEMENTA NE PAS UTILISER POUR POMPER DES LIQUIDES EXPLOSIFS OU INFLAMMABLES ESSENCE HUILE KEROSENE ETC NE PAS UTILISER DANS UN ENVIRONNEMENT PROPICE AUX EXPLOSIONS UTILISER AVEC DES LIQUIDES COMPATIBLES AVEC LES MATERIAUX DE LA POMPE NE PAS MANIPULER LA PUMPE LES MAINS HUMIDES LES PIEDS POSES SURE UNE SURFACE MOUILLEE OU HUMIDE OU LES PIEDS DANS L EAU VOTRE POMPE VIENT AVEC UN FIL DE MISE A LA TERRE ET OU UNE PRISE A TROIS BRANCHES AFIN DE REDUIRE LE RUSQUE DE CHOC ELECTRIQUE S ASSURER QUE LA POMPE EST BRANCHEE A UNE PRISE CORRECTEMENT MISE A LA TERRE L UTILISATION D UN OU DE PLUSIEURS SYSTEMES AUXILIAIRES ET OU D UN SYSTEME D ALARME EST RECOMMANDEE POUR TOUTE INSTALLATION POTENTIELLEMENT DANGEREUSE FUITE OU DEFECTUOSITE CAUSEES PAR UNE COUPURE DE COURANT UN BLOCAGE DU CIRCUIT DE REFOULEMENT OU POUR TOUTE AUTRE RAISON POUR LES PERSONNES OU LA PROPRIETE IMMOBILISER LA POMPE ET LES TUYAUX LORS DE L INSTALLATION ET DE L UTILISATION AFIN D EVITER TOUT RISQUE DE DOMMAGES AUX TUYAUX A LA POMPE AUX ROULEMENTS A BILLE DU MOTEUR ETC INSTALLATION 1 Avant d installer la pompe laisser le climatiseur effectuer quelques cycles pour collecter le condensat dans un contenant s par afin de faciliter evacuation des huiles r siduelles qui pourraient rester dans le syst me 2 D baller la pompe avec pr caution en faisant gliser l emballage Enleve
6. IPO POLARIZADO Y ADECUADAMENTE CONECTADO A TIERRA EN CUALQUIER INSTALACION DONDE PUEDAN OCURRIR DA OS MATERIALES Y O LESIONES PERSONALES QUE RESULTEN DEL FUNCIONAMIENTO INADECUADO O DE FUGAS EN LA BOMBA A CAUSA DE FALLOS EN LA ALIMENTACION ELECTRICA BLOQUEO DE LA LINEA DE LA DESCARGA O CUALQUIER OTRA RAZON SE DEBERA USAR UNO O VARIOS SISTEMAS DE RESPALDO Y O ALARMAS IAPOYE LA BOMBA Y LA TUBERIA DURANTE EL ENSAMBLADO DE LA UNIDAD Y AL COMPLETAR LA INSTALACION EL NO HACERLO ASI PUEDE CAUSAR LA RUPTURA DE LA TUBERIA EL FALLO DE LA BOMBA EL FALLO DE LOS COJINETES DEL MOTOR ETC INSTALACI N Antes de instalar la bomba permita que el aire acondicionado realice varios ciclos recolectando la condensaci n en un contenedor separado para ayudar a vaciar cualquier aceite residual que pueda permanecer en el sistema Desempaque la bomba cuidadosamente Quite el embalaje de cart n de los orificios de ventilaci n de la cubierta del motor Retire el embalaje de la bomba haci ndolo deslizar cuidadosamente Este embalaje se usa para evitar el movimiento de los interruptores durante el transporte Figura 1 Montaje de la bomba el tanque tiene dos ranuras destinadas a montar la unidad Las ranuras se encuentran situadas en el extremo de la cubierta del tanque Figura 5 La unidad deber montarse al lado de la unidad del acondicionador de aire o en una pared cercana a ella La bomba deber estar nivelada y la toma deber
7. LE FABRICANT NE PEUVENT TRE TENUS RESPONSABLES DE TOUTE BLESSURE TOUTE PERTE OU TOUT DOMMAGE DIRECT INDIRECT OU ACCESSOIRE INCLUANT MAIS NON EXCLUSIVEMENT LES VENTES OU PROFITS PERDUS LES ATTEINTES AUX PERSONNES OU A LA PROPRIETE OU TOUTE AUTRE PERTE INDIRECTE OU ACCESSOIRE RESULTANT DE L UTILISATION OU DE L INCAPACIT D UTILISATION DE LA POMPE ET L ACHETEUR CONVIENT QU IL NE DISPOSE D AUCUN AUTRE RECOURS L acheteur doit s assurer que la pompe convient l usage projet il assume aussi tout risque et toute responsabilit relative ment cet usage Certaines juridictions ne permettent pas la limitation de la dur e d une garantie ou l exclusion ou la limitation de responsabilit pour des dommages indirects ou accessoires Par cons quent il est possible que la limitation ou l exclusion indiqu e pr c demment puisse ne pas tre applicable Cette garantie vous donne des droits particuliers et peut tre d autres d pendamment des juridictions en vigueur Le code national de l lectricit et autres codes semblables d autres pays exigent l installation d un interrupteur avec mise la terre GFI sur le circuit d alimentation de la fontaine pour toute installation dont la tension est sup rieure a 15 volts Nous offrons de tels interrupteurs avec diff rentes longueurs de fil et nous recomman dons que chaque pompe soit reli e a un interrupteur de ce type GARANTIA LIMITADA El producto que Little Giant le of
8. Little GIANT Franklin El Co VCMA 10 ranklin Electric Co Inc P O Box 12010 VCMA 1 5 Oklahoma City OK 73157 2010 405 947 2511 Fax 405 947 8720 VCMA 20 www LittleGiantPump com CustomerService WTS fele com INTRODUCTION Your Little Giant condensate pump is designed as an automatic condensate removal pump for water dripping off an air conditioner evaporative coil The pump is controlled by a float switch mechanism which turns the pump on when approximately 2 1 4 of water collects in the tank and automatically switches off when the tank drains to approximately 1 1 4 The Little Giant unit you have purchased is of the highest quality workmanship and material It has been engineered to give you long and reliable service Little Giant pumps are carefully packaged inspected and tested to ensure safe operation and delivery When you receive your pump examine it carefully to determine that there are no broken or damaged parts that may have occurred during shipment If damage has occurred make notation and notify the firm that you purchased the pump from They will assist you in replacement or repair if required READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OPERATE OR SERVICE THE LITTLE GIANT PUMP KNOW THE PUMP APPLICATION LIMITATIONS AND POTENTIAL HAZARDS PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE
9. aci n no aumente por debajo del nivel de acidez promedio de 3 4 para evitar una bolsa de cido que actuar a como una pila causando una corrosi n localizada limpiando o enjuagando rutinaria mente el tanque con agua limpia Figure 7 al b a B B l l l l l l l l l l l zuo amp 4 5 lt 8 lt rala lt Bal Sal Bal 2al Gal Zal Kalal Ra EEE S lsolsolsolse 35 5525 lso 9 3S s5 35 35 36 Ewa P N DESCRIPTION DESCRIPTION DESCRIPCI N B gt b gt ob gt o gt l H gt H gt H gt HS HS BS BS oH gt o gt o gt o gt 1 154401 Tank Black ABS R servoir Noir ABS Tanque Negra ABS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 154411 Tank Cover ABS Couvercle Reservoir ABS Cubierta Del Tanque ABS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 154491 Volute Motor Assy Ensemble Volute Moteur Ensamblaje Voluta Motor 115V 60Hz 1 1 1 1 3 154492 Volute Motor Assy Ensemble Volute Moteur Ensamblaje Voluta Motor 115V 60Hz 1 1 1 1 154493 Volute Motor Assy Ensemble Volute Moteur Ensamblaje Voluta Motor 230V 50 60Hz 1 1 1 1 1 1 154494 Volute Motor Assy Ensemble Volute Moteur Ensamblaje Voluta Motor 230V 50Hz 1 Motor Cover ABS Natural Couvercle Carter De Moteur ABS Naturel 4 154421 cubierta Caja Del Motor ABS Natural A IE EN ES EE EE A
10. almac n se encuentran GFCI de 115 voltios con varias longitudes de cable y recomendamos que cada bomba sea usada con un GFCI Essaie ea e 1 888 572 9933 alii do dea a De 1 888 956 0000 EE a ii arate 1 888 572 9933 Pour l aide technique entrez s il vous plait en contact 1 888 956 0000 Para partes o la reparaci n por favor p ngase en contacto ENE 1 888 572 9933 Para la ayuda t cnica por favor p ngase en contacto 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com Form 998086 04 14 2009 2009 Franklin Electric Co Inc Little Giant is a registered trademark of Franklin Electric Co Inc
11. cated elsewhere it is not economical due to duties and freight to return the pump to the factory for inspection Please return the defective unit to any authorized distributor or dealer with a brief written explanation of the problem If there are no apparent signs of customer abuse unit will be repaired or replaced If dispute arises over replacement of the pump the distributor or dealer is to seg regate such items and hold for inspection by a representative of Franklin Electric Co Inc or notify factory with details of the problem for factory disposition and settlement of warranty claim DISCLAIMER THE FOREGOING WARRANTY IS AN EXCLUSIVE WARRANTY IN LIEU OF ANY OTHER EXPRESS WARRANTIES ANY IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT EITHER APPLIES TO A PUMP SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESS WARRANTIES GIVEN ABOVE Warranty will be VOID if any of the following conditions are found 1 Sealed motor housing opened Product connected to voltage other than indicated on nameplate Cord cut off to a length less than three feet Pump allowed to operate dry fluid supply cut off ar wo D Pump used to circulate anything other than water 6 Product abuse by customer Any oral statements about the product made by the seller the manufacturer the representatives or any other parties do not constitute warranties s
12. cesidad de una v lvula de retenci n Figura 5 Si no es posible colocar en declive la tuber a de descarga haga un purgador en forma de U invertida directamente sobre la bomba en el punto m s alto INSTRUCCIONES DE SERVICIO 1 Asegurese de que la unidad este desconectada de la fuenta de alimentacion electrica antes de intentar prestar servicio a la unidad o quitar cualquier componente de ella 2 Aseg rese de que el flotador se mueva libremente Limpie cuando sea necesario Figura 6 3 Limpie el tanque con agua caliente y con un jab n suave 4 Verifique la tuber a de entrada y salida Limpie cuando sea necesario Aseg rese de que no haya torceduras en la l nea que puedan detener el paso del l quido COMPROBACION 1 Conecte la electricidad 2 Quite el conjunto del motor y la cubierta del tanque y cons rvelo nivelado 3 Pruebe el interruptor del motor levantando su flotador con el dedo Figura 6 El motor deber activarse antes de que el flotador entre en contacto con la cubierta 4 Pruebe el interruptor de seguridad levantando su flotador con el dedo El interruptor de seguridad deber activarse antes de que el flotador entre en contacto con la cubierta 5 Vuelva a colocar sobre el tanque el conjunto de la cubierta del motor y la cubierta del tanque La bomba es adecuada para el uso en aguas de condensaci n de hornos de gas Debe tenerse cuidado de verificar que la acidez del agua de condens
13. dio para el comprador ser la reposici n y o reparaci n del producto por parte del fabricante bajo las condicio nes descritas anteriormente NI EL VENDEDOR NI EL FABRICANTE SE HACEN RESPONSABLES DE NINGUNA LESION PERDIDA O DANO DIRECTO INCIDENTAL O CONSECUENTE INCLUYENDO PEROSIN LIMITARSEA DANOS INCIDENTALES O CONSECUENTES DEBIDO A GANANCIAS PERDIDAS VENTAS PERDIDAS DANOS A PERSONAS O PROPIEDADES O CUALQUIER OTRA PERDIDA INCIDENTAL O CONSECUENTE QUE RESULTE DEL USO O DE LA IMPOSIBILIDAD DEL USO DEL PRODUCTO Y EL COMPRADOR ACUERDA QUE NO EXISTE OTRO REMEDIO DISPONIBLE PARA EL Antes de usar el usuario debe determinar si el producto se adapta al uso desea do y el usuario asume todos los riesgos y responsabilidades en relaci n a ello Algunos estados y pa ses no permiten limitaciones sobre la duraci n de una garant a impl cita o la exclusi n o limitaci n de da os incidentales o consecuentes de manera que las limitaciones o exclusiones anteriores podr an no tener aplicaci n en su caso Esta garant a le da derechos legales espec ficos y usted podr a dispon er tambi n de otros derechos que var an de un estado a otro y de un pa s a otro El C digo El ctrico Nacional en los Estados Unidos y c digos similares en otros pa ses requieren un Interruptor de circuito de falla de conexi n a tierra GFCI para ser instalado en el circuito secundario que suministra equipo de fuente calibrado por encima de 15 voltios En el
14. e tuyau d coulement jusqu la bonne hauteur Ne pas l tirer au dessus de la t te GPH du mod le install De ce point haut incliner l g rement le tuyau d coulement vers un point situ au dessus de lieu d coulement rabattre et tirer jusqu un point situ en doussous ou peu pr s au m me niveau que le bas du syst me de condensation ce qui donnera un effet de siphon qui en augmentera l efficacit et liminera pratiquement l installation d une soupape d arr t Figure 5 S il n est pas possible d incliner le tuyau d coulement faire un branchement en U invers un point situ le plus haut au dessus de la pompe DIRECTIVES D ENTRETIEN 1 Votre pompe demandera tr s peu d entretien Si pour une raison quelconque elle ne peut pas fonctionner suivez les instructions ci dessous 2 Veillez ce que les flotteurs bougent librement Nettoyez les au besoin Figure 6 8 Nettoyez le r servoir l eau ti de et au savon 4 V rifiez la tuyauterie d alimentation et de sortie Nettoyez la au besoin Assurez vous que les tuyaux ne pr sentent aucun tortillement pouvant influer sur le d bit V RIFICATION 1 Mettre la pompe en marche 2 Enlever le couvercle qui couvre l ensemble moteur r servoir et le supporter de niveau 3 Tester le commutateur de moteur en levant le commutateur de moteur du flotteur avec le doigt Figure 6 Le moteur doit se mettre en marche avant que le flotteur ne to
15. encontrarse debajo de la bobina de drenaje Los accesorios de tubo aislador no son compatibles con la caja pl stica de la bomba La bomba no deber a instalarse de tal forma que quede expuesta a salpicaduras o rociaduras Esta bomba no est preparada para usar dentro de la c mara impelente de aire CONEXIONES ELECTRICAS Desconecte la corriente el ctrica en la caja de fusibles antes de hacer cualquier conexi n El tendido de cables debe ajustarse totalmente a la legislaci n local Voltaje de la l nea conecte el cable el ctrico a una l nea del voltaje especificado en el motor y en la placa del constructor El cable el ctrico debe estar conectado a una fuente constante de electricidad no un ventilador u otro dispositivo que funcione de manera intermitente Si el cable el ctrico carece de enchufe los cables son los siguientes verde o verde y amarillo a tierra negro o marr n circuito blanco o azul neutro Interruptor de seguridad el interruptor de seguridad de exceso sobre la capacidad debe encontrase conectado a un circuito de bajo voltaje de la clase Il Para controlar un circuito termost tico las conexiones COM y NO del interruptor de seguridad tienen que ser conectadas en serie con el circuito del termostato de bajo voltaje para que apague el sistema de calefacci n aire acondicionado Los contactos COM y NC del interruptor pueden usarse para activar un circuito de bajo voltaje de a
16. erruptor 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 929602 Drain Hole Plug Bouchon Orifice D coulement Tap n Agujero De Desag e 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 12 154455 Float Pivot Pin Axe De Pivotement Du Flotteur Pasador De Pivote De Flotante 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 13 951941 Lead Wire Assy Assemblage Fils Plumb s Conjunto De Hilos Conductores 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Safety Switch Assy Montage Interrupteur De S curit 14 154465 Conjunto De Interruptor De Seguridad x 1 7 1 1 1 i 1 1 15 944302 Tubing not shown Tube non illustr Tuberia 3 8 x 1 2 x 20 no se muestra 1 1 1 1 1 1 Table 1 LIMITED WARRANTY Your product is guaranteed to be in perfect condition when it leaves our factory It is warranted against defective materials and workmanship for a period of 12 months from date of purchase by the user Any product that should fail for either of the above two reasons and is still within the warranty period will be repaired or replaced at the option of Little Giant as the sole remedy of buyer For our customers in the CONTINENTAL UNITED STATES Please return the defective unit postage paid to the factory at 301 North MacArthur Blvd Oklahoma City OK 73127 6616 All defective product returned under warranty will be fully inspected to determine the cause of failure before warranty is approved For our customers lo
17. g is used to prevent switch movement during shipment Figure 1 3 Mounting the pump the tank has two slots provided to mount the unit The slots are located on the ends of the tank Figure 5 The unit should be mounted either on the side of the air conditioner unit or nearby wall Pump must be level and the inlet must be below the coil drain Conduit fittings are not compatible with the plastic pump housing 4 The pump should not be installed in a manner that will subject it to splashing or spraying 5 This pump is not intended for use inside air plenums ELECTRICAL CONNECTIONS 1 Shut off electrical power at fuse box before making any connections All wiring must comply with local codes 2 Line voltage Connect power cord to line voltage specified on motor and nameplate Power cord must be connected to a constant source of power not a fan or other device that runs intermittently If power cord does not have a plug wiring is as follows green or green yellow ground Black or brown line White or blue neutral 3 Safety switch The safety overflow switch should be connected to a class II low voltage circuit To control a thermostatic circuit the COM and NO connections from the safety switch are to be wired in series with the low voltage thermostat circuit to shut down the heating AC circuit The COM and NC switch contacts may be used to actuate a low voltage alarm circuit connected in series if the heating cooling
18. hall not be relied upon by the user and are not part of the contract for sale Seller s and manufacturer s only obligation and buyer s only remedy shall be the replacement and or repair by the manufacturer of the product as described above NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS LOST SALES INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT Before using the user shall determine the suitability of the product for the intended use and user assumes all risk and liability whatsoever in connection therewith Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you spe cific legal rights and you may also have other rights which vary from state to state and country to country The National Electric Code in the USA and similar codes in other countries require a Ground Fault Circuit Interrupter GFCI to be installed in the branch circuit sup plying fountain equipment rated above 15 volts 115 volt GFCI s with various cord lengths are in stock a
19. ie Il Pour commander un circuit thermostatique les connexions COM et NO de l interrupteur de s curit doivent tre branch es en s rie avec le circuit basse tension du thermostat il est alors possible de couper le systeme de chauffage climatisation Si une telle coupure n est pas d sir e les contacts COM and NO peuvent aussi tre utilises pour activer une alarme de faible tension branch e en s rie L interrupteur de s curit a t r gl en usine avec des fils raccord s aux bornes COM et NO L assemblage typique de circuits NC serait Figures 2 amp 3 4 Siune prise avec fusible est utilisee sous une tension de 230 V l utilisation d un fusible de 1 amp re est recommand e TUYAUTERIE 1 Courant flexible tubage ou pipe d s evaporator drain into 1 de la 3 pompe inlets Pour permettre un bon coulement s assurer que le tuyau d admission est bien dirig e vers le bas Figure 4 Introduire le tuyau d entr e de 1 3 pouces de 2 5 7 5 cm l int rieur du r servoir afin de s assurer qu il ne nuise pas au fonctionnement du flotteur V rifier que le tuyau d entr e est coup en angle son entr e dans le r servoir 2 Le tuyau de sortie s il est flexible doit tre fix avec une pince tuyaux non comprise S il est rigide il ne doit pas d passer 3 8 po 0 5 cm de D I afin d viter un reflux excessif vers la pompe partir de l unit d extraction tirer verticalement l
20. la bomba o debajo si es posible Figure 4 PIPING Run flexible tubing or pipe from evaporator drain into one ofthe three pump inlets Be sure inlet piping is sloped downward to allow gravity flow Figure 4 Extend the inlet piping into the tank from 1 to 3 inches to ensure that it will not interfere with proper float operation Be sure that the inlet piping is cut at an angle where it enters the tank The outlet piping should be flexible tubing secured with a hose clamp not provided or pipe 3 8 inch I D maximum to prevent excessive flow back to unit From condensate unit extend discharge piping straight up as high as necessary Do not extend this line above the head GPH of the particular model being installed From this high point slope discharge line down slightly to a point above drain area then turn down and extend to a point below or approximately level with the bottom of the condensate unit This will give a siphoning effect which will improve efficiency of the condensate unit and will in most cases eliminate the need for a check valve Figure 5 If it is not possible to slope discharge line down make an inverted U trap directly above the pump at the highest point SERVICE INSTRUCTIONS Make certain that the unit is disconnected from the power source before attempting to service or component remove any Be sure the floats move freely Clean as necessary Figure 6 Clean the tank with warm water and mild soa
21. larma conectado en serie si el sistema de calefacci n aire acondicionado no puede ser interrumpido El interruptor de seguridad se suministra desde la f brica con los cables conectados a los bornes COM y NO del interruptor El prototipo de la conexi n de los circuitos abiertos ser a Figuras 2 amp 3 Si se utiliza un enchufe con fusible en unidades a 230 V se recomienda el uso de un fusible de 1 0 amperio TUBERIA Corra flexible tuberia o pipe desde evaporator alcantarilla into 1 de el 3 bomba inlets Cerci rese de que la tuberia de la toma se encuentre en declive para permitir el flujo por gravedad Figura 4 La tuberia de descarga debe ser una tuberia flexible o tubos de un diametro interno maximo de 3 18 de pulgada para evitar un reflujo excesivo a la unidad Desde la unidad de agua de condensaci n extienda la tuberia directamente hacia arriba a la altura que sea necesaria No tienda esta tuberia por encima de la cabeza GPH del modelo especifico que se est instalando Desde esta altura coloque la tuberia de descarga en declive ligero hasta un punto por encima del area de drenaje Luego vu lvala hacia abajo y ti ndala hasta un punto que se encuentre aproximadamente al mismo nivel del fondo de la unidad de agua de condensaci n o por debajo de ste Esto producir un efecto de sif n que incrementar la eficiencia de la unidad de agua de condensaci n y en la mayor a de los casos eliminar la ne
22. nd we recommend each pump be used with a GFCI GARANTIE LIMITEE La pr sente garantit que votre pompe est en parfaite condition a sa sortie de l usine La pompe est garantie contre tout d faut de mat riau ou de fabrication pendant une p riode de 12 mois a partir de la date d achat initial Tout produit encore garanti qui serait d fectueux pour l une des deux raisons sus mentionn es sera r par ou remplac a la discr tion du Little Giant L acheteur n aura pas d autre recours Pour nos clients aux ETATS UNIS territoire continental seulement Veuillez retourner l article d fectueux suffisamment affranchi lusine l adresse suivante 301 North MacArthur Blvd Oklahoma City OK 73127 6616 Tous les produits garantis retourn s feront l objet d une inspection d taill e afin de d ter miner si la d fectuosit est couverte par la garantie Pour les clients a l ext rieur des Etats Unis tant donn les frais de douane et de transport il n est pas conomique de retourner la pompe lusine pour inspection Exp dier la pompe ainsi qu une br ve description du probl me tout distributeur ou d taillant autoris Si elle ne pr sente aucun signe apparent d une mauvaise utilisation elle sera remplac e ou r par e S il y a conflit sur la n cessit de remplacer la pompe le distributeur ou le d taillant devra garder celle ci et soit la fera inspecter par un repr sentant du le Fabricant soit avisera lusine du p
23. p 4 Check the inlet and outlet piping Clean as necessary Be sure there are no kinks in the line that would inhibit flow TESTING 1 Turn on power Remove motor tank cover assembly and hold level Test motor switch by raising motor switch float with finger Figure 6 Motor should turn on just before float contacts cover Test safety switch by raising safety switch float with finger Safety switch should activate before float contacts cover Replace motor tank cover assembly on tank Check Valve Soupape d arr t V lvula de Retenci n Figure 5 Mounting Slots Fentes d assemblage Ranuras de montaje Figure 6 Safety Switch Float Commutateur de S curit de Flotteur Flotador del Interruptor de Seguridad Motor Switch Float Commutateur de Moteur de Flotteur Flotador del Interruptor del Motor This pump is suitable for gas furnace condensate applications Caution must be taken to ensure acidity of condensate does not increase below the average pH of 3 4 to prevent localized pocket of acid that acts like a battery causing pitting by routinely cleaning or flushing tank with fresh water INTRODUCTION Votre pompe a condensats Little Giant est concue comme une unite automatique d evacuation des condensats Elle evacuel eau condensee egouttant de la volute de l evaporateur d un systeme de climatisation La pomp est actionee par un mechisme flotteur interru
24. pteur lequel entraine le demarrage dela pompe oorsque environ 2 po 1 4 d eau s accumule dans le reservoir La pompe s arrete automatiquement lorsqu il ne reste plus qu environ 1 po 1 4 d eau Votre nouvelle pompe Little Giant a t fabriqu e avec les meilleurs mat riaux et avec le plus grand soin Elle a t congue pour foncionner bien et longtemps Les pompes Little Giant sont soigneusement emball es et test es pour assurer une livraison et un fonctionnement sans probl mes Lorsque vous recevez votre pompe examinez la attentivement pour vous assurer qu il n y a pas eu de piece cass e ou endommag e pendant acheminement S il y a eu des d gats prenez en note et signalez le au magasin o vous avez achet la pompe Ils vous aideront pour le remplacement ou la r paration si n cessaire Cette pompe est congue pour pomper de eau NE POMPEZ PAS de produit chimique de solvant d eau sal e ou de liquides pais tels que des huiles ou de la graisse BIEN LIRE LES INSTRUCTIONS AVANT D INSTALLER DE FAIRE FONCTIONNER OU D ENTRETENIR LA POMPE LITTLE GIANT IL FAUT CONNA TRE L APPLICATION LES LIMITESET LES DANGERS POTENTIELS DE LA POMPE PROTEGEZ VOUS ET LES AUTRES EN RESPECTANT TOUTES LES NORMES DE SECURITE LE NON RESPECT DES INSTRUCTIONS PEUT CAUSER DES ATTEINTES AUX PERSONNES OU A LA PROPRIETE GARDER LE PRESENT DOCUMENT POUR REFERENCE ULTERIEURE L INSTALLATION ET LES BRANCHEMENTS DOIVENT ETRE EFFECTUES P
25. r l emballage de carton des fetes d a ration qui se trouvent sur le courvercle du moteur Cet emballage est destin viter le mouvement des commutateurs pendant le transport Figure 1 3 Montage Deux fentes situ es l extr mit du couvercle de r servoir permettent le montage Celui ci doit tre fait pr s d un climatiseur ou d un mur Figure 5 La pompe doit tre niveau et l arriv e doit se trouver sous le serpentin d coulement Son carter en plastique n est pas compatible avec la tuyauterie 4 viter d installer la pompe o elle pourrait tre clabouss e ou arros e 5 Cette pompe n a pas t con ue pour l int rieur de chambres de r partition d air CONNEXIONS ELECTRIQUES 1 Avant de faire les connexions couper le courant lectrique fusibles et s assurer que tous les fils sont conformes au Code local de l lectricit 2 Ligne de tension Le c ble lectrique doit tre connect la ligne de tension comme sp cifi sur le moteur et sur la plaque de constructeur La connexion doit tre faite une source constante et non une source intermittente comme un ventilateur Si le c ble lectrique n est pas quip d une prise les fils se pr sentent de la fa on suivante vert ou vert et jaune la terre noir ou marron ligne de tension blanc ou bleu neutre 3 Disjoncteur Le disjoncteur de d bordement doit tre connect un circuit basse tension de cat gor
26. rece est garantizado a estar en perfectas condicio nes al momento de salir de la f brica El producto est garantizado contra materiales y fabricaci n defectuosa por un per odo de 12 meses desde la fecha en la cual fue comprada por el usuario Cualquier producto que falle por alguna de las dos razones anteriores y que est dentro del per odo de garant a ser reparado o reemplazado a opci n de Little Giant y ste ser el nico remedio del comprador Para nuestros clientes en los ESTADOS UNIDOS CONTINENTALES Por favor devolver la unidad defectuosa con el porte pagado a la f brica en 301 North MacArthur Blvd Oklahoma City OK 73127 6616 Todo producto defectuoso devuelto bajo la garant a ser cuidadosamente inspec cionado para determinar la causa de la falla antes de aprobar la garant a Para nuestros clientes ubicados en otros lugares no es econ mico devolver la bomba a la f brica para que sta sea inspeccionada debido a los impuestos y al flete For parts or repair please contact For technical assistance please contact Pour des parties ou la r paration entrez s il vous plait en contact Por favor devuelva la unidad defectuosa a cualquier distribuidor o vendedor autor izado con una breve explicaci n por escrito del problema Si no existen se as aparentes de abuso por parte del cliente la unidad ser reemplazada o reparada Si se produce una disputa sobre el reemplazo de la bomba el distribuidor o
27. robl me afin de conna tre la d cision de celle ci et le r glement de la r clamation D N GATION LA GARANTIE NONC E DANS LES PR SENTES EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE OU IMPLICITE CELA COMPORTE MAIS NON EXCLUSIVEMENT TOUTE GARANTIE IMPLICITE D APTITUDE A LA COMMERCIALISATION OU D APTITUDE PARTICULIERE POUVANT S APPLIQUER A UNE POMPE LITTLE GIANT DE PLUS ELLE NE S APPLIQUE QUE DURANT LA PERIODE DE COUVERTURE PRECISEE CI DEVANT La pr sente garantie sera ANNULEE si 1 Le boitier scell du moteur a t ouvert 2 Le branchement a une tension autre que celle indiqu e sur la plaque du fabri cant a t effectu 3 Le fil d alimentation a t coup a une longueur inf rieure amp 0 91 m trois pieds 4 La pompe a tourn vide l alimentation en liquide a t coup e 5 La pompe a t utilis e pour faire circuler des liquides autres que de l eau 6 La pompe a t mal utilis e Toute d claration sur la pompe faite oralement par le vendeur le fabricant le repr sentant ou par toute autre partie ne constitue pas une garantie et par con s quent ne peut servir l utilisateur De plus une telle d claration ne peut en aucun cas faire partie du contrat de vente L unique obligation du vendeur et du fabricant et unique recours de l acheteur est le remplacement ou la r paration de la pompe selon les modalit s d crites pr c demment NI LE VENDEUR NI
28. system can not be disrupted The safety switch comes from the factory with leads connected to the COM and NO switch terminals Typical hook up of NC circuits would be Figures 2 amp 3 4 If fused plug is used on 230V units a 1 0 amp fuse is recommended Connect here to turn alarm on Brancher ici pour allumer l alarme Conecte aqui para activar la alarma Connect here to turn D thermostat off Brancher ici pour teindre le thermostat Conecte aqui para desactivar el termostato NOTE All wiring to be done by qualified service technician Refer to local codes in your area Remarque la pose de tous les fils doit tre faite par un technicien agr Se r f rer au Code local NOTA Todos los calbes deben colocarse por un t cnico apacitado en reparaciones Remitase a las leyes locales de su area Figure 2 1 Safety Switch Low Voltage Class I Commutateur de Securite Basse Tension de Categorie Il Interuptor de Seguridad Bajo Voltaje Classe 11 Discharge Line Installation Installation de la ligne d coulement Instalacion de la tuber a de descarga Inverted U Trap X Siphon en U invers Purgador en forma de U invertida _Slope down from highest point inclinaison partir du point le plus haut Coloque en declive desde el punto mas alto Drop to bottom of pump or below if possible Drainage au bas de la pompe ou en cessous si possible Ll vese al fondo de
29. uche le couvercle 4 Tester la s curit du commutateur en levant le commutateur de s curit de flotteur avec le doigt Le commutateur de s curit doit se mettre en marche avant que le flotteur ne touche le couvercle 5 Replacer le couvercle sur l ensemble Cette pompe convient aux applications des condensats de radiateurs gaz Certaines pr cautions doivent tre prises pour viter que l acidit du condensat ne descende en dessous du pH moyen de 3 4 ce qui causerait la formation lacalis e d une poche d acidit qui fonctionnerait comme une batterie et causerait de la corrosion Il est recommand de nettoyer ou de rincer p riodiquement le r servoir l eau claire INTRODUCCI N Su bomba de condensacion Little Giant esta disenada como una bomba de remocion de condenscion automatica para remover agua que gotea de las bobinas evaporantes de una unidad de aire acondicionado La bombs esta controlada por un mecanismo flotador interruptor que activa la bomba aproximadamente cuando 2 1 4 de agua so junta en el tanque y se apaga automaticamente cuando elnnivel del agua baja a aprozimadamente 1 1 4 La unidad Little Giant que usted ha adquirido posee la mas alta calidad de fabricaci n y materiales Ha sido dise ada para brindarle una larga vida de servicio sin problemas Las bombas Little Giant se envasan cuidadosamente registradas y probadaspara asegurar la entrega y operaci n segura Cuando usted recibe su bomba