Home
ELITE-15 DM i - Furman Sound
Contents
1. Protection OK Indicator Although the Furman SMP circuit assures virtually maintenance free protection from transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any transient voltage surge suppression device to absorb without some degree of damage In the rare instance that this occurs the blue LED located in the center of the front panel will dim even though AC power is present at the unit s outputs If this happens some level of protection from voltage surges will remain but the Furman s clamping voltage rating will be compromised The unit must be returned to Furman Sound or an authorized Furman Service center for repair NOTE If the mains power is above the high cutoff voltage and has caused the unit to remove power from its outlets it cannot restore power without the operator manually turning the unit off then on again Avoid turning the unit back on without first checking the source of the problem and perhaps changing the AC source Telco Satellite Cable Transient Voltage Surge Suppressors s The Elite 15 DM i features transient voltage surge suppression for both standard telephone lines as well as cable or satellite lines utilizing standard coaxial connectors As these surge suppressors are in line they will require an additional cable to connect from their output to the control device requiring protection All in line surge suppressors feature
2. FURMAN ELITE 15 DM i LINEAR FILTERING AC POWER CONDITIONER CONDITIONNEUR D ALIMENTATION C A AVEC TECHNOLOGIE FILTRAGE LIN AIRE ACONDICIONADOR DE L NEA DE AC CON FILTRAJE LINEAR Owner s MANUAL Guipe DE L UTILISATEUR MANUAL DE USUARIO FURMAN ELITE 15 DM i Owner s MANUAL ENGLISH Page 4 IE ELITE 15 DM i Guipe DE L UTILISATEUR FRANGAIS Page 12 ELITE 15 DM i MANUAL DE USUARIO ESPANOL Page 20 All content 2007 Furman Sound LLC All Rights Reserved Printed in China FURMA EuTe 15 DM i OwNER S MANUAL Elite 15 DM i Features UEM Linear Filtering Technology for unequaled audio and video clarity Series Multi Stage Protection provides virtually maintenance free AC surge suppression Laboratory grade dual voltage and current meters Zero ground contamination circuitry protects critical digital component 12 volt triggering for remote control Introduction For over 34 years Furman has pioneered the development of AC power products for the most demanding audio video and broadcast professionals Though the need for pristine AC power is nothing new the Elite 15 DM i s technology and its unique implementation are revolutionary and without peer The extreme AC demands encountered in the professional audio video arena have required technological developments far in excess of typical home theater audiophile power products In studios live sound and broadcast f
3. l interrupteur d alimentation situ sur le panneau avant Les huit autres prises du panneau arri re sont commutables et exigent un dispositif de d clenchement 12 V comme on en trouve g n ralement sur la plupart des r cepteurs et des pr amplificateurs audio L entr e de d clenchement 12 V est une prise casque mono Un produit additionnel avec d clenchement comme un caisson d extr mes graves install distance peut tre reli en s rie partir de la prise de sortie 12 V Ceux qui d sirent d sactiver la fonction de d clenchement 12 V peuvent utiliser le pratique bouton poussoir de d rivation qui est situ c t des prises d entr e et de sortie En appuyant sur ce bouton toutes les prises seront activ es une fois allum l interrupteur d alimentation du panneau avant AVERTISSEMENT si le bouton de d rivation 12 V n est pas enfonc l alimentation de quatre des prises sera coup e jusqu ce que la fonction de d clenchement 12 V soit activ e Tout composant de contr le central comme un r cepteur avec t l commande universelle principale devrait tre reli une prise non commutable Dans le cas contraire une fois la t l commande universelle teinte il sera impossible de r tablir l alimentation du r cepteur au moyen de la t l commande Indicateur de tension et de courant c a M Votre unit Elite 15 DM i comporte un indicateur de tension d entr e de la ligne c a de pr cision ainsi qu un indicateur d
4. en serie con otras tiras de alimentaci n Fuentes de alimentaci n UPS Universal Power Supply otros protectores de picos adaptadores de 3 terminales a 2 o cables de extensi n Cualquier instalaci n de este tipo invalidar esta garant a La garant a de Furman solo protege contra da o de equipo propiamente conectado donde Furman ha determinado a su nica discreci n que el da o resultante de lo ocurrido y que no se pudo proteger contra actos de Dios otros que no son luz tales como inundaciones terremotos guerra terrorismo vandalismo robo desgaste y rasgu os por uso normal erosi n agotamiento obsolescencia abuso da o debido a disturbios de bajo voltaje sobrecargas de centro de carga entre otros programas no autorizados o alteraci n o modificaci n del equipo en el sistema No use este producto de ninguna manera con un generador calentador bombas de aceite dispositivos relacionados con agua dispositivos para apoyo a la vida como dispositivo m dico en autom viles motocicletas o como cargador de bater as para carros de golf Para uso en interiores solamente y en reas secas Todas las garant as contenidas adjuntas son nulas e inv lidas si se usa de cualquier forma con alguno de los dispositivos ya mencionados LA PRECEDENTE EST EN LUGAR DEL RESTO Y TODAS LAS GARANT AS EXPRESAS O IMPLICADAS INCLUYENDO PERO NO LIMITADO A LAS GARANT AS IMPLICADAS DE MERCADIBILIZACI N Y APTITUD PARA UN PROPOSITO ESPEC FICO Fur
5. l quipement endommag et compl ter le formulaire de demande au titre de la garantie de Furman couvrant l quipement connect appelez Furman au 707 763 1010 pour obtenir ce formulaire Furman se r serve le droit d examiner le produit Furman endommag l quipement connect qui a t endommag et le lieu o les dommages sont survenus Tous les frais d exp dition d un quipement endommag Furman aux fins d inspection doivent tre assum s par l Acheteur L quipement endommag doit tre disponible aux fins d inspection jusqu la fin du traitement de la demande La garantie de Furman couvrant l quipement connect est galement valable pour une p riode de trois ans moins que l Acheteur ne compl te pas l enregistrement de garantie dans les quinze jours suivant la date d achat d lai apr s lequel la garantie couvrant l quipement connect sera r duite un an compter de la date d achat Toutes les garanties contenues dans les pr sentes sont nulles et sans effet si le limiteur de surtension de Furman en fonction pendant l v nement n est pas envoy Furman la charge de l Acheteur aux fins d inspection la demande de Furman Furman d termine que le limiteur de surtension de Furman a t ouvert incorrectement install modifi de facon quelconque ou trafiqu Furman d termine que les dommages ne r sultent pas de l v nement ou qu aucun v nement n a eu lieu ou si Furman d termine que l quipem
6. mais le facteur de blocage de l unit sera compromis L unit doit tre retourn e chez Furman Sound ou un centre de r paration autoris de Furman 15 FURMA EurE 15 DM i Guipe DE L UTILISATEUR Remarque Si l alimentation secteur est sup rieure a la tension de blocage de mani re provoquer la coupure d alimentation des prises de l unit cette derni re ne peut r tablir l alimentation aussi longtemps que l op rateur n a pas teint puis rallum manuellement l unit vitez de remettre l unit sous tension sans avoir pr alablement d termin la source du probl me et peut tre avoir chang la source c a Suppresseurs de surtension transitoire pour lignes de signaux par satellite lignes coaxiales de cablodistribution lignes t l phoniques mu L unit Elite 15 DM i assure une suppression de surtension transitoire autant pour les lignes t l phoniques standard les lignes coaxiales de c blodistribution et les lignes de signaux par satellite utilisant des connecteurs coaxiaux standard Comme ces suppresseurs de surtension fonctionnent en ligne in line ils requi rent un c ble additionnel pour relier leur sortie au dispositif de contr le n cessitant une protection Tous les suppresseurs de surtension en ligne sont dot s de notre technologie exclusive pr venant la contamination par la terre Cette derni re permet d liminer les perturbations au niveau audio et les barres de ronflement au niveau vid o qui sont
7. profondeur et la nettet au niveau de l image Gr ce la technologie de filtrage lin aire exclusive Furman les t l viseurs les projecteurs les lecteurs DVD les amplificateurs et les processeurs recoivent une alimentation c a filtr e de facon lin aire contribuant r duire consid rablement le bruit c a tout en assurant un fonctionnement sup rieur et uniforme peu importe les conditions de charge ou le moment de la journ e Pour la premi re fois vous obtiendrez un syst me de cin ma maison ou un syst me de sonorisation sans compromis autant au niveau de l image qu au niveau du son De plus notre circuit exclusif de protection plusieurs tages en s rie constitue aussi une autre caract ristique importante Cette suppression des surtensions non sacrificielle assure le niveau de protection c a le plus lev qui soit sans interruption advenant une surtension s v re aucun quipement endommag aucun appel de service aucun temps d arr t Nos indicateurs de tension et de courant c a permettent de mesurer pr cis ment les charges en courant d entr e de la ligne c a une fonction pr cieuse lorsque vous surveillez des syst mes qui sont reli s aux r seaux lectriques actuels susceptibles de fournir une alimentation de pi tre qualit En outre l intensit des indicateurs peut tre r duite si la surveillance n est pas n cessaire Lorsque vous utiliserez l unit Elite 15 DM i vous constaterez imm diatement que v
8. Philips t te tronconique incluses dans le kit de montage La troisi me vis utilis e pour chaque querre de montage s installe dans le trou central situ vers l arri re et stabilise l unit une fois mont e en b ti 13 FURMA EurE 15 DM i Guipe DE L UTILISATEUR Connexion Acheminement du cable c a Le cordon c a Edison m le de l unit Elite 15 DM i doit tre reli une extr mit femelle appropri e se reporter aux recommandations susmentionn es sur le courant nominal Branchement de composants sur les prises Video Component AC Outlet Les prises Video Component AC Outlet de l unit Elite 15 DM i devraient tre utilis es pour les composants vid o essentiels tels que les lecteurs DVD les projecteurs les crans plasma ou les crans vid o ACL Se reporter la section D clenchement 12 V ci dessous Branchement de composants sur les prises avec filtrage lin aire Les prises Audio Audio Video Power Outlet sur les panneaux arri re et avant de l unit Elite 15 DM i devraient tre utilis es pour les composants non reli s aux prises Video Component AC Outlet Ces prises offrent galement un filtrage du bruit c a exceptionnel de mani re optimiser le rendement du syst me Se reporter la section D clenchement 12 V ci dessous D clenchement 12 V Mise sous tension Les prises mont es une sur panneau avant et quatre sur panneau arri re de l Elite 15 DM i s sont toujours activ es une fois allum
9. a limitada mantiene la entera obligaci n de Furman con respecto al producto Si alguna parte de esta garant a limitada se determina inv lida o ilegal el resto permanecer con toda la fuerza y efecto El reclamo de garant a deber acompa arse de una copia de la factura de compra original donde se muestre la fecha de compra Si la tarjeta de registro de garant a fue enviada por correo en el periodo de compra o si el producto fue registrado en l nea esto no es necesario Antes de regresar cualquier equipo para reparaci n aseg rese que esta debidamente empaquetado y amortiguado contra da os de transportaci n y que esta asegurado 25 FURMA ELITE 15 DM i MANUAL DE USUARIO Especificaciones Capacidad de corriente de AC Entrada Capacidad requerida de 15 amperes Salida 15 amperes RMS m ximo todas las terminales combinadas y continuas Atenuaci n de Ruido Linear Modo Transversal Diferencial gt 40dB de 10khz a 100kHz gt 80dB de 100khz a 1GHz Curva de atenuaci n linear de 0 05 a 1000 de impedancia de l nea Supresi n de picos de voltaje transitorios 120 VAC Protecci n en Serie Multi Etapa No sacrificatorio con cero contaminaci n de tierra 188V pico 6000V 3000A de entrada Apagado de Voltaje Extremo gt 140 VAC Telco Cable Sat lite menor a 0 1dB de p rdida por inserci n Consumo 12Watts por los circuitos de control y display independiente de la carga Terminales o enchufes 9 enchufes con fi
10. acompa ada por una copia de la factura original de compra mostrando la fecha de compra esto no es necesario si el registro de la garant a se ha completado ya sea habiendo enviado la tarjeta de garant a llena por correo o habi ndose registrado en l nea en el sitio de Internet de Furman Los cargos de env o ala f brica de Furman o al centro de servicio local autorizado por Furman deber n ser realizados por el comprador y por adelantado Furman deber bajo su propio costo reparar o reemplazar el producto defectuoso seg n las opciones que tenga Furman Los gastos de env o de regreso del producto al comprador ser n pagados por Furman Garant a de equipo conectado La garant a de equipo conectado de Furman Sound cubre equipo que es da ado por voltajes transitorios en ocurrencia cuando esta correctamente conectado a trav s del Elite 15 DM i y cuando ste esta conectado auna l nea de AC con una tierra f sica de protecci n en un lugar interior o cerrado La garant a de equipo conectado de Furman se limita a la cantidad del deducible en la p liza personal de seguro del comprador y que es de arriba de 500 00 Para demandar o reclamar esta garant a de equipo conectado el comprador debe enviar una copia de su reclamo de p liza de seguro personal por el equipo da ado a Furman y completar la forma de reclamo de la garant a de equipo conectado de Furman llamar a Furman al 707 763 1010 para obtener la forma Furman se reserva el der
11. en segundos con un m dulo nuevo de TVSS Para probar esto simplemente desconecte el cable que entra y sale del Elite 15 DM i Conecte el conector de entrada al componente que antes recib a el conector de salida as estar salt ndose la protecci n en l nea Si la se al esta presente pero no cuando se usa el Elite 15 DM i entonces el circuito de protecci n esta da ado asuma que ste trabajo adecuadamente antes de una tormenta o un evento catastr fico Garantia mE Furman Sound LCC Garantiza al comprador original de este producto el Elite 15 DM i de Furman que el producto esta libre de defectos en materiales y fabricaci n por un periodo de 3 afios a partir de la fecha de compra Al comprador de este producto se le permite que en los 15 d as despu s de la compra llene el registro de garant a y lo env e por correo o en l nea en la p gina de Internet de Furman Si el comprador falla en completar el registro ya mencionado el periodo de garant a se reducir a 1 a o a partir del d a de compra Si el producto no cumple con esta garant a limitada durante el periodo de garant a como se especifico arriba el comprador debe de notificarlo a Furman de manera escrita describiendo los defectos Si los defectos son del tipo y naturaleza que esta garant a cubre Furman autorizar al comprador a regresar el producto a la f brica de Furman o a un centro de servicio local autorizado por Furman La reclamaci n de garant a deber de ser
12. intensit efficace Le premier situ gauche sur le panneau avant surveille continuellement la tension d entr e de la ligne c a Le deuxi me situ droite sur le panneau avant lit l appel de courant c a total de vos syst mes g n ralement 0 1 A peu importe la charge c a Remarque Nous avons ajout une commande d intensit d di e aux indicateurs bleus de tension et de courant pour ceux qui installent l unit Elite 15 DM i de mani re ce qu elle soit visible pendant l utilisation L utilisateur peut ainsi r gler l intensit lumineuse de l affichage de facon optimiser la visualisation de toute source vid o lorsque les lumi res de la salle sont teintes 14 Suggestion de connexion Caisson de Gradateur sous graves Table Lecteur DVD HD DVD cran Plasma double amplifi tournante SACD ou lecteur Blu Ray ou ACL D viation lecteur CDr VCR ou DVR Projecteur Prises t l phoniques x2 Sorties audio vid o Commutables Sorties audio Commutables Sorties vid o ERE Ata RN AUDIO VIDEO VIDEO OUTLETS SWITCHED 1800 WATT MAXIMUM CAPACITY m gt z N 2 UM AUDIO VIDEO OUTLETS SWITCHED Sorties vid o Non Commutables Sorties audio vid o Non Commutables Sorties audio Cordon d alimentation Non Commutables Dispositif de d clenchement 12V Prises c ble Amplificateur Processeur audio R cepteur satellite satel
13. prises combin es en continu Att nuation du bruit Mode transversal diff rentiel 40 dB de 10 kHz 100 kHz 80 dB de 100 kHz 1 GHz Courbe d att nuation lin aire avec imp dance de ligne de 0 05 100 ohms m E gt z N 2 Fal Suppression de surtension transitoire Ligne 120 V c a Protection plusieurs tages en s rie non sacrificielle avec contamination nulle par la terre Tension d cr tage de 188 V 6 000 V 3 000 A en entr e Arr t en cas d extr me tension 140 V c a Telco C ble Satellite Perte de moins de 0 1 dB au niveau de la ligne Consommation d nergie 12 W pour l affichage et les circuits de commande ind pendamment de la charge r elle Prises 9 prises avec technologie de filtrage lin aire panneau arri re 2 commutables avec la fonction de d clenchement 12 V 4 prises avec technologie de filtrage lin aire et filtrage ultrasonore additionnel pour les composants num riques ou vid o 2 commutables avec la fonction de d clenchement 12 V Dimensions H x Lx P 10 16 x 43 18 x 37 46 cm 4 x 17 x 14 75 po format 1 U standard sans les pieds Poids 14 lb 19 FURMA ELITE 15 DM i MANUAL DE USUARIO Caracteristicas del Elite 15 DM i mm Tecnolog a de Filtraje Linear para una claridad de audio y video sin igual Provee la Protecci n en Serie Multi Etapa que virtualmente mantiene libre y suprime los picos de voltaje o corriente de AC Doble medidor de V
14. rie partir d une boite de disjoncteurs domestique Le circuit SMP Series Multi Stage Protection d tecte les tensions suffisamment lev es pouvant emp cher le fonctionnement et coupe l alimentation avant que ne surviennent d ventuels dommages la mise sous tension de ces unit s l indicateur DEL d arr t an cas d extr me tension s allumera si la tension d entr e exc de le seuil de tension extr me et les prises de l unit ne seront plus aliment es Si l unit fonctionne avec une tension d entr e acceptable et que la tension exc de par la suite 140 V ou chute sous 85 V il coupera l alimentation de la prise et l indicateur DEL d arr t an cas d extr me tension s allumera Le circuit tentera une r initialisation automatique dans un d lai de 5 secondes Ainsi les r initialisations manuelles sont n cessaires uniquement dans le cas d un d faut de c blage permanent Indicateur Protection OK Bien que le circuit SMP de Furman assure une protection pratiquement sans entretien contre les surtensions transitoires la nature peut parfois cr er des charges lectriques qui d passent les capacit s de tout appareil avec suppression des surtensions transitoires les absorber sans entrainer certains dommages Dans ce cas tr s rare l indicateur bleu situ au milieu du panneau avant s teindra m me en pr sence de courant c a au niveau des prises de l unit Dans ce cas un certain niveau de protection contre les surtensions subsiste
15. the Elite 15 DM i s construction design or componentry to wear over the life time of the product and there is no power draw from your electric service meter aside from the LED power indicator and relay circuits For this reason the Elite 15 DM i may be left with its power engaged permanently at a cost of pennies per month 6 AC Transient Voltage Surge Suppression and Extreme Voltage Shutdown s m z O n r Extreme Voltage Shutdown Indicator This LED is normally off It monitors AC wiring faults for example accidental connection to an open neutral from a 208 or 240VAC feed this is a common occurrence if the 15 Amp outlet source is not a dedicated line but instead has been wired with a daisy chained neutral from a homes breaker box The Series Multi Stage Protection SMP circuit senses voltages that are so high that operation would be impossible and shuts the power down before damage can occur Upon initially applying power to these units the Extreme Voltage indicator LED will light if the input voltage is above the extreme voltage cutoff and power will not be applied to the unit s outlets If the unit has been operating with an acceptable input voltage and subsequently that voltage exceeds 140V or falls below 85V it will shut off power to the outlet and the Extreme Voltage LED will light The circuit will attempt to re set automatically within 5 seconds so manual re set will only be necessary if there is a permanent wiring fault
16. y apagado por voltaje extremo A Indicador de apagado por voltaje extremo EI LED esta normalmente apagado Este monitorea fallas en el cableado de AC por ejemplo una conexi n accidental de un punto neutro a alimentaci n de 208 o 240VAC esto ocurre com nmente si un enchufe de 15 amperes no tiene una l nea dedicada pero en su lugar se ha cableado con un neutro conectado en cadena daisy chained del centro de carga de la casa El circuito de Protecci n en Serie Multi Etapa SMP Series Multi stage Protection sensa el voltaje que es muy alto y con el cual es imposible operar y deshabilita la alimentaci n antes de que pueda existir alg n da o Al iniciar la alimentaci n de esta unidad el LED indicador de Voltaje Extremo se encender si la entrada de voltaje esta arriba del umbral de voltaje extremo en donde se apaga y la alimentaci n no se liberar a los enchufes de la unidad Si la unidad se ha estado operando con una entrada de voltaje aceptable y subsecuentemente este voltaje excede 140V o cae debajo de 85V se apagara y no enviar voltaje a los enchufes adem s de que la luz de Voltaje Extremo se encender El circuito tentativamente se reajustar autom ticamente en 5 segundos de esta forma el reajuste manual solamente ser necesario si existen fallas de cableado permanentes m 4 v gt z e Indicador de Protecci n OK Aunque el circuito de Furman SMP asegura virtualmente una protecci n libre de mantenimiento de p
17. acilities breakdown is unacceptable Equipment failure or poor performance is costly The same is true of today s home theater Our solution based technology extensive engineering expertise and robust build quality have answered the challenge of today s corrupted power lines and led to the creation of the Elite 15 DM i Today s power lines are plagued with RF and EMI noise When connecting sensitive equipment to your home s power outlet AC noise couples into your system s critical components This AC noise masks low level signals and cripples performance This low level content is critical because it relays the crucial harmonics and ambience in audio as well as the depth and clarity in video With Furman s exclusive Linear Filtering Technology televisions projectors DVD players amplifiers and processors are fed linearly filtered AC power This dramatically reduces noise ensuring consistent peak operation regardless of load conditions or the time of day For the first time you will see and hear your theater or audio system as it should be uncompromised Another critical feature is our exclusive Series Multi Stage Protection This virtually maintenance free surge suppression assures the highest level of AC protection possible without sacrificing itself when the offending surge is severe no damaged equipment no service calls no down time Further our digital AC voltage and current meters allow precise measurements of the incoming AC line an
18. based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Furman be liable for incidental special or consequential damages Furman s employees or representatives ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES shall not be relied upon by purchaser and are not a part of the contract for sale or this limited warranty This Limited Warranty states the entire obligation of Furman with respect to the product If any part of this Limited Warranty is determined to be void or illegal the remainder shall remain in full force and effect Warranty claims should be accompanied by a copy of the original purchase invoice showing the date of purchase if a Warranty Registration Card was mailed in at the time of purchase or if the product was registered on line this is not necessary Before returning any equipment for repair please be sure it is adequately packed and cushioned against damage in shipment and that it is insured FURMA A EuTe 15 DM i Owner s MANUAL Specifications AC Current Capacity Input 15 Amp capacity required Output 15 Amps RMS maximum all outlets combined continuous Linear Noise Attenuation Transverse Differential Mode gt 40 dB from 10Khz 100 kHz gt 80 dB from 100 Khz 1GHz Linear attenuation curve from 0 05 100 ohms line impedance Transient Voltage Surge Suppression 120 VAC Series Multi Stage Prote
19. ce s est d grad e e l unit Elite 15 DM i est tomb e ou le bo tier est endommag e l unit Elite 15 DM i exige la pr sence d une prise de terre de s curit pour assurer un fonctionnement ad quat Source d alimentation La source d alimentation laquelle est reli e l unit Elite 15 DM i doit tre ad quate de facon assurer un fonctionnement 15 A L Elite 15 DM i fonctionnera si elle est reli e une prise de courant de 10 A Cependant il peut survenir un d clenchement nuisible au niveau du panneau disjoncteurs si l appel de courant continu des syst mes exc de 10 A Montage L unit Elite 15 DM i est dot e de quatre pieds en caoutchouc de mani re permettre une installation sur tout type de table d armoire d tag re ou de plancher Ces pieds sont faciles retirer au moyen d un tournevis Philips standard pour assurer le montage en b ti c t d autres composants L installation de l unit Elite 15 DM i proximit d autres composants est sans danger En outre l unit Elite 15 DM i ne produit aucune chaleur appr ciable sous des conditions normales d utilisation et elle peut tre mont e en b ti dans une baie standard de 19 po en utilisant les querres de montage en b ti Ces querres de montage incluses dans l emballage en plastique de kit de montage sont mont es fleur l arri re de la surface du panneau avant de l unit Elite 15 DM i Elles se fixent au ch ssis en vissant les trois 3 vis
20. ci n frontal sea encendido Advertencia jSi el bot n de bypass de los 12V no se presiona 4 enchufes no entregaran voltaje hasta que un voltaje de disparo de 12V este presente Cualquier componente de control primario tal como un receptor con control remoto universal maestro deber ser conectado a un enchufe unswitched Si no lo hace una vez que el control remoto universal se apague no habr manera de restablecer la alimentaci n al receptor v a control remoto Medidores de AC de Voltaje y Corriente NN Su Elite 15 DM i posee una combinaci n de medidores de alta precisi n de Voltaje de AC de entrada as como de Corriente RMS El primer medidor localizado en el lado izquierdo del panel delantero continuamente monitorea el Voltaje de AC de entrada El medidor de Corriente est localizado en el lado derecho del panel delantero y medir la Corriente total drenada en el sistema 0 1 amperes t picamente no importando la carga Nota Para aquellos que montan el Elite 15 DM i donde puede ser visible durante su uso hemos incluido un interruptor de atenuaci n dimmer en el panel trasero para los medidores azules de Voltaje y Corriente Esto permite al usuario atenuar estas luces cuando las luces del cuarto se hayan apagado para una visualizaci n de video ptima Conexiones de AC Sugeridas Atenuador DVD HD DVD de medidores Subwoofer S as JE Activo Tornamesa r DUR LCD Monitor Dispositivo Pea Proyector Protector
21. control que requiere protecci n Todos los supresores de picos en l nea poseen nuestra exclusiva tecnolog a de contaminaci n de tierra libre Esto ayuda a eliminar ruido de audio y ruido visto como barras en el video que resultan por el uso de supresores en l nea t picos Adem s nuestros supresores de cable y sat lite son amigables con DVR y est n preparados para televisi n digital de Alta Definici n Se ales con portadoras de DC as como se ales con anchos de banda amplios pueden pasar a trav s de nuestro circuito De hecho la p rdida es menor a 0 1dB a 1GHz de ancho de banda 23 FURMA ELITE 15 DM i MANUAL DE USUARIO Para conectar su cable a trav s de estos protectores en l nea simplemente siga los indicadores de entrada IN y salida OUT marcados al lado del Telco conectores de Cable y Sat lite Nota No es posible hacer que un protector en l nea de cable y o sat lite sea libre de mantenimiento como se realiza con uno para l nea de 120VAC Eso necesita un ancho de banda de se al limitado que no permita pasar a la se al Bajo condiciones extremas es posible que un supresor de picos en uno de estos dispositivos se pueda sacrificar despu s de un evento catastr fico Si la se al del tel fono cable o sat lite no pasa m s por nuestro protector por favor contacte a un representante de servicio local instalador o a Furman para su servicio Puesto que estos circuitos son modulares el reemplazo se puede lograr
22. ction Non Sacrificial with Zero Ground Contamination 188 V peak clamping 6000V 3000A input Extreme Voltage Shutdown gt 140 VAC Telco Cable Satellite less than 1dB insertion loss Power Consumption 12 Watts for display and control circuits independent of actual load Outlets 9 linearly filtered outlets rear panel 6 switching 12V triggered 4 linearly filtered outlets with additional ultrasonic filtering for digital or video components 2 switching 12V triggered Dimensions 4 H x 17 W x 14 75 D Standard 2 RU height without feet Weight 14 lbs 10 FURMA EurE 15 DM i Guipe DE L UTILISATEUR Caract ristiques de l unit Elite 15 DM i m Technologie de filtrage lin aire LiFT pour Linear Filtering Technology assurant une clart sans pr c dent au niveau du son et de l image Circuit de protection plusieurs tages en s rie SMP pour Series Multi Stage Protection assurant une suppression des surtensions c a sans entretien e Deux indicateurs de tension et de courant de qualit laboratoire Circuit pr venant la contamination par la terre pour prot ger les composants num riques essentiels Fonction de d clenchement 12 V pour contr le distance Introduction A Depuis plus de 34 ans Furman ne cesse d innover en mati re de produits de conditionnement d alimentation c a destin s aux professionnels les plus exigeants uvrant dans les domaines de l audio de la vid o et de la rad
23. d current loads These meters are a valuable asset when monitoring systems that are connected to today s potentially poor power grids or the meters may be dimmed when monitoring is not required When employing the Elite 15 DM i you will notice far clearer stunningly focused sound and visual images from your system Video presentation will be crisp and colors true with greater gray and black scale definition as well as noticeably improved depth and clarity Many of the technological advances previously available only in our flagship Reference Conditioners are cornerstones of the Elite series Now everyone can reap the benefits of unrivaled power purification and unequalled surge suppression Installation A Unpacking Before unpacking your unit inspect the carton for any obvious severe damage to the box and internal protective materials If internal damage is likely contact the carrier who delivered the unit before proceeding with unpacking If after unpacking shipping damage is evident contact the carrier Save all shipping and packing materials You may need them if you should ever have to return the unit to the factory for servicing The box should contain the Elite 15 DM i unit rack mount kit owner s manual and warranty registration card If anything is missing please contact Furman Customer Service Fill out and return your warranty registration card Registration is recommended because it can be used to establish whether the unit is wi
24. echo de revisar el producto Furman da ado el equipo conectado da ado y el sitio donde ocurri el da o Todos los costos de env o del equipo da ado a Furman para inspecci n deben ser cubiertos por el comprador El equipo da ado debe estar disponible para inspecci n hasta que el reclamo haya finalizado La garant a de equipo conectado tambi n tiene una vigencia de 3 ahos a menos que el comprador no complete el registro de garant a en los 15 d as despu s del d a de compra al tiempo en el cual el periodo de la garant a de equipo conectado tambi n se reduce a 1 a o a partir del d a de compra Todas las garant as contenidas adjuntas son nulas e inv lidas si El protector de picos de Furman en uso durante el evento no se provee a Furman para inspecci n por requerimiento de Furman y que es el nico gasto para el comprador Furman determinar que el protector de picos se ha abierto se ha instalado de manera incorrecta alterado de alguna forma o tratado de forzar Furman determinar que el da o no es resultado de lo ocurrido o no ocurrido en el lugar o Furman determinar que el equipo conectado no fue usado bajo condiciones normales de operaci n o en correspondencia con las instrucciones del fabricante para conectar equipo Todos los protectores de picos de Furman deben ser conectados directamente a una l nea 24 de alimentaci n de AC apropiadamente cableada con tierra f sica y no debe de estar conectada en cadena Daisy chained
25. ent connect n a pas t utilis sous des conditions normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement une ligne d alimentation c a ad quatement c bl e avec une mise la terre de s curit et ne doivent pas tre connect s en s rie avec d autres lisi res prises multiples UPS limiteurs de surtension adaptateurs deux et trois broches ou autres rallonges De telles installations auraient pour effet d annuler la pr sente garantie La garantie de Furman couvre uniquement les dommages caus s l quipement correctement connect dans le cas o Furman sa seule discr tion a jug qu ils r sultent d un v nement Elle ne couvre pas les dommages attribuables l un ou l autre des cas fortuits autre que la foudre suivants inondation tremblement de terre guerre acte de terrorisme acte de vandalisme vol usure normale usage abusif mauvais traitement rosion d pl tion d su tude dommages r sultant d une basse tension c d panne de courant localis e ou baisse de tension programme non autoris modification ou alt ration de l quipement En aucun cas vous ne devez utiliser ce produit avec une g n ratrice un appareil de chauffage une pompe de puisard un appareil dont l utilisation est li e l eau un appareil de maintien en vie un appareil m dical une automobile une
26. es Telco x2 de disparo Enchufes de Audio Audio Video Enchufes de Video de 12V Switched Switched cc AUDIO AUDIO VIDEO VIDEO OUTLETS OUTLETS OUTLETS Be es CHED VIDEO OUTLETS Enchufes de Audio Enchufes Enchufes de Video Cable de AC Unswitched Audio Video Unswitched Switched Protectores Cable Boton E Amplificador de Procesador Pre Receptor de Satelite Cable Satelite x3 bypass dedos A canales 2 7 Receptor amplifacador de 12V de disparo audio 22 Inicio Suave Uso Continuo vo Cuando se le aplica alimentaci n por primera vez al Elite 15 DM i El interruptor de encendido Breaker debe ser colocado en la posici n de on o prendido la funci n de inicio suave esta activada Se escuchar un sonido audible de clack cuando el Elite 15 DM i sea prendido o apagado por primera vez Este sonido es producido por el circuito de Inicio Suave Relevador de 30 amperes de inicio suave cuando se acopla o desacopla No hay virtualmente nada en la construcci n del Elite 15 DM i en su dise o o componentes usados para determinar el tiempo de vida del producto y no hay un consumo de energ a o alimentaci n considerable que medir en su servicio el ctrico m s que el del LED indicador de alimentaci n y los circuitos relevadores Por esta raz n el Elite 15 DM i se debe dejar con su palanca de alimentaci n encendida permanentemente ya que el costo es insignificante por mes Supresion de picos transitorios de voltaje de AC
27. h the Elite 15 DM i then the protection circuit is damaged assuming it worked properly before a storm or catastrophic event FURMAN EuTe 15 DM i Owner s MANUAL Warranty Furman Sound LLC warrants to the original purchaser of this product the Furman Elite 15 DM i that the product will be free from defects in material and workmanship for a period of three years from the date of purchase The purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on line at the Furman website If the purchaser fails to complete the aforementioned registration the warranty period will be reduced to one year from the date of purchase If the product does not conform to this Limited Warranty during the warranty period as herein above specified purchaser shall notify Furman in writing of the claimed defects If the defects are of such type and nature as to be covered by this warranty Furman shall authorize the purchaser to return the product to the Furman factory or to an authorized Furman repair location Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date this is not necessary if the Warranty Registration was completed either by mailing in the completed warranty card or by registering on line at the Furman website Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the purchaser of the product Fu
28. he left of the front panel continuously monitors the incoming AC voltage The current meter located to the right of the front panel and will read your systems total AC current draw 0 1 amp typically regardless of the AC load Note For those that mount the Elite 15 DM i where it could be visible during use we have included a rear panel mounted dimmer switch for the blue voltage and current meters This allows the user to dim these lights when the room lights are turned off for optimum video viewing Suggested AC Connection Dual Meter Powered SACD Player DVD HD DVD Plasma Dimmer Subwoofer Turntable CD Changer Blu Ray Player LCD Monitor 12V or Player VCR or DVR Projector Telco Protectors x2 Triggering Audio Outlets Audio Video Outlets Video Outlets Device Switched Switched Switched DEO AUDIO AUDIO VI OUTLETS OUTLETS eu Audio Outlets Audio Video Outlets Video Outlets Unswitched Switched Unswitched Cable Satellite c tor Ke 2 7 Channel Audio Pre Amplifier Satellite SE an Amplifier Receiver Processor Receiver Cable Box Soft Start Gontinuous Use When power is first applied to the Elite 15 DM i the front panel breaker power toggle must be switched to the on position the Soft Start feature is activated There is an audible clack when the Elite 15 DM i is first turned on or off This sound is produced by the Soft Start circuit s 30 Amp relay engaging or disengaging There is virtually nothing in
29. icos y transitorios de voltaje la naturaleza genera ocasionalmente fuerzas el ctricas que van m s all de las capacidades de cualquier dispositivo supresor de picos trascientes de voltaje y que ser n absorbidas con un grado de da o En el extra o caso de que ocurra el LED de color Azul localizado al centro del panel delantero parpadear aun as la alimentaci n de AC estar presente en los enchufes de la unidad Si esto pasara alg n nivel de protecci n de los picos de voltaje quedar o se mantendr pero el rango de voltaje protegido por Furman no ser el correcto La unidad deber ser enviada a Furman Sound o a un centro de servicio autorizado por Furman para su reparaci n Nota Si la alimentaci n principal esta arriba del umbral de voltaje alto y esto causar que la unidad no libere alimentaci n a los enchufes de la unidad la alimentaci n no se podr reestablecer sin que el operador manualmente apague la unidad y luego la encienda Evite encender de regreso la unidad sin primeramente haber revisado la fuente del problema y quiz s cambiarla fuente de AC Supresor de picos transitorios de voltaje para cable satelite Telco s El Elite 15 DM i posee un supresor de picos transitorios de voltaje para l neas telef nicas est ndar y l neas de cable y o sat lite que utilizan conectores coaxiales est ndar Como estos supresores de picos est n en l nea requerir n un cable adicional para conectarlo de su salida al dispositivo de
30. inales de alimentaci n de tu casa el ruido de AC se filtra a los componentes m s cr ticos de tu sistema El ruido de AC enmascara se ales de bajo nivel y deteriora el desempe o del equipo El contenido de nivel bajo es cr tico porque estos poseen muchos arm nicos y ambiente cruciales en audio tambi n como la claridad y profundidad en video Con la exclusiva tecnolog a de Filtraje Linear de Furman las televisiones proyectores DVD amplificadores y procesadores se alimentaran con AC linealmente filtrada Lo anterior reduce dram ticamente el ruido asegurando una operaci n consistente en picos no importando las condiciones de carga o el tiempo de uso al d a Por primera vez ver s y escucharas tu sistema de cine en casa o tu sistema de audio como deber a de ser sin compromisos Otra caracter stica cr tica es nuestra exclusiva protecci n en Serie Multi Etapa Esta supresi n que no sacrifica picos asegura el m s alto nivel de protecci n de AC sin entregar su vida cuando un pico es severo sin da os al equipo sin llamadas a servicio sin tiempo perdido Adem s nuestros medidores digitales de Voltaje y Corriente de AC permiten hacer mediciones precisas de la se al de AC que entra y de las cargas actuales Estos medidores son muy valiosos cuando se monitorean sistemas que est n conectados a las potencialmente pobres terminales de alimentaci n de hoy d a los medidores se pueden atenuar cuando no se requiere monitoreo Cuando em
31. iodiffusion Bien que le besoin pour une alimentation c a pure n ait rien de nouveau la technologie de l unit Elite 15 DM i et sa mise en ceuvre unique sont r volutionnaires et sans gal Les besoins extr mes en alimentation c a qu exige le mat riel audio vid o professionnel ont conduit des d veloppements technologiques beaucoup plus pouss s que ceux applicables aux produits d alimentation types de cin ma maison et d audiophile Pour les studios les installations de sonorisation et de radiodiffusion les d faillances sont inacceptables Les pannes d quipement et les mauvais rendements sont source de d penses importantes Il en est de m me pour les cin mas maisons actuels Notre technologie fond e sur des solutions notre grande expertise en mati re d ing nierie et notre qualit de fabrication ont surmont les enjeux que posent les lignes d alimentation affect es d aujourd hui et ont conduit la cr ation de l unit Elite 15 DM i Les radiofr quences et les interf rences lectromagn tiques en augmentation constante affectent les lignes d alimentation d aujourd hui Lorsque vous branchez des quipements sensibles sur vos prises de courant domestiques le bruit c a atteint les composants essentiels de votre syst me de mani re masquer les signaux de faible intensit et d t riorer le rendement Ces signaux sont importants car ils transmettent les harmoniques essentielles et l ambiance au niveau du son ainsi que la
32. ional AC noise filtering to maximize system performance See 12V triggering below FURMA EuTe 15 DM i Owner s MANUAL 12V Triggering Switching The Elite 15 DM i s front panel and four of the rear panel mounted outlets are always on once the front panel power switch is engaged The remaining eight rear panel outlets are labeled switched these require a 12 volt triggering device such as that typically found in most power receivers and audio pre amp processors The input for the 12V trigger is a female mono mini phone jack An additional product such as a remote sub woofer can be daisy chained from the 12V output jack for an additional triggered unit For those who do not wish to utilize the 12V triggering a convenient bypass push button switch is located adjacent to the input and output jacks By depressing this button all outlets will operate when the front panel power switch is engaged WARNING If the 12V bypass switch is not engaged four of the outlets will not supply power until a 12V trigger is present Any primary control component such as a receiver with a master universal remote should be connected to an unswitched outlet If not once the universal remote is turned off there will be no way to restore power to the receiver via the remote control AC Voltage and Current Meters s Your Elite 15 DM i contains a combination precision incoming AC voltage meter as well as a true RMS current meter The first meter located towards t
33. les se hayan perdido adem s de que nos ayuda a informarle sobre actualizaciones u otra informaci n vital Informaci n de seguridad Advertencias Por favor lea y observe todas las instrucciones de operaci n y seguridad antes de operar y hacer funcionar el Elite 15 DM i Conserve y guarde esas instrucciones para referencias futuras No desarme ni modifique nada No hay partes de servicio reemplazables por el usuario Mant ngalo lejos de humedad y evite la humedad excesiva No permita que l quidos u objetos extra os entren a la unidad El Elite 15 DM i debe mandarse a servicio con personal calificado cuando Cuando el cable de alimentaci n y o la clavija hayan sido da ados o cortados Cuando ala unidad le hayan ca do objetos o se le haya derramado un l quido Cuando se haya expuesto a la lluvia u otra humedad e Cuando parezca que no esta operando de forma normal o exhiba un marcado cambio en su desempe o Cuando se haya ca do o se haya da ado su armaz n m 4 v gt z e El Elite 15 DM i necesita una tierra f sica segura para su correcta operaci n Fuente de Alimentaci n La fuente de alimentaci n en la cual se conecta el Elite 15 DM i debe ser adecuada para manejar 15 amperes El Elite 15 DM i opera con enchufes de 10 amperes sin embargo puede existir un disparo del circuito breaker que hay en el panel delantero si la corriente continua de drenaje del sistema excede los 10 amperes Co
34. lite x3 r cepteur de 2 7 pr amplifi ou bo te pour cable canaux Mise sous tension sans appel de courant Soft Start Utilisation continue mn la mise sous tension de l unit Elite 15 DM i l interrupteur d alimentation du panneau avant doit tre en position On la fonction Soft Start est activ e Vous entendrez un claquement la premi re mise sous ou hors tension de l unit Elite 15 DM i Ce bruit est produit par l engagement ou le d sengagement du relais de 30 A du circuit de mise sous tension sans appel de courant Pratiquement aucun l ment au niveau de la construction de la conception ou des composants de l unit Elite 15 DM i ne s usera au cours de la dur e de vie du produit et il n y a aucun appel de courant important l exception de l indicateur d alimentation DEL et des circuits du relais Pour ces raisons l unit Elite 15 DM i peut demeurer sous tension de facon permanente un co t mensuel minime Suppression de surtension transitoire pour lignes c a et arr t en cas d extr me tension s Indicateur d arr t en cas d extr me tension L indicateur DEL d arr t en cas d extr me tension est normalement teint Il d tecte les d fauts de c blage c a par exemple la connexion accidentelle un fil neutre d une source de 208 ou 240 V caa cette situation survient fr quemment lorsque la prise de 15 A n est pas une ligne d di e et qu elle a plut t t reli e un fil neutre connect en s
35. locaci n El Elite 15 DM i se manufactura con cuatro patas de goma para su colocaci n en cualquier mesa gabinete repisa mueble o piso Las patas de goma pueden ser removidas f cilmente con un desarmador Philips Est ndar cuando se vaya a montar en rack adyacentemente a otro componente La colocaci n o proximidad a otros componentes no es cr tica y el Elite 15 DM i no produce ning n calor negativo bajo condiciones normales de uso El Elite 15 DM i tambi n se puede montar en un rack est ndar de 19 colocando sus orejas para rack Estas orejas para rack contenidas en la bolsa pl stica del kit de montaje en rack se colocan o montan con la porci n trasera del panel frontal del Elite 15 DM i Se colocan en el chasis del mismo instalando cada oreja para rack con 3 tornillos contenidos en el kit de montaje en rack del Elite 15 DM i El tercer tornillo usado para cada oreja de rack es para el hoyo del centro localizado hacia atr s y ayuda a estabilizar la unidad cuando se monta en rack Conexion rom Cable de AC El cable con conector Edison macho de AC deber ser conectado a un enchufe apropiado Vea el rango de corriente recomendado arriba Conectando componentes a las terminales de AC de componentes de Video Los enchufes de AC de Video Componentes del Elite 15 DM i deben ser empleados para componentes de video cr ticos tales como reproductores de DVD proyectores Plasmas o pantallas de video LCD Refi rase a la explicaci n de lo
36. loor These rubber feet may be easily removed with a standard Philips screw driver when rack mounting adjacent to other components Placement or proximity to other components is not critical and the Elite 15 DM i does not produce any appreciable heat under standard use The Elite 15 DM i may also be rack mounted in a standard 19 rack by attaching the Elite 15 DM i rack ears These rack ears contained within the plastic rack kit package mount flush with the back portion of the Elite 15 DM i s front panel They are attached to the chassis by installing each rack ear with 3 pan head Philips screws contained within the Elite 15 DM i rack mounting kit The third screw used for each rack ear is for the center hole located towards the rear and aids in stabilizing the unit when rack mounted Connection vo AC Cable Routing The Elite 15 DM i s male Edison AC cord must be connected to an appropriate socket see current rating recommendation above Connecting Components to the Video Component AC Outlet Banks The Elite 15 DM i s Video Component AC Outlets should be employed for critical video components such as DVD players projectors plasma or LCD video screens See 12V triggering below Connecting Components to the Linear Filtering Power Banks The Elite 15 DM i s rear panel and front panel Audio Audio Video Power Outlets should be employed for any component not connected to the Video Component AC Outlets These outlets still possess except
37. lso reduced to one year from the date of purchase All warranties contained herein are null and void if the Furman Surge Protector in use during the occurrence is not provided to Furman for inspection upon Furman s request at the sole expense of the Purchaser Furman determines that the Furman Surge Protector has been opened improperly installed altered in any way or tampered with Furman determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating conditions or in accordance with Manufacturer s instructions for the connected equipment All Furman Surge Protectors must be plugged directly into a properly wired AC power line with a protective ground and must not be daisy chained together in serial fashion with other power strips UPS s other surge protectors three to two prong adapters or extension cords Any such installation voids this warranty The Furman warranty only protects against damage to properly connected equipment where Furman has determined at its sole discretion that the damage resulted from an Occurrence and does not protect against acts of God other than lightning such as flood earthquake war terrorism vandalism theft normal use wear and tear erosion depletion obsolescence abuse damage due to low voltage disturbances i e brownouts or sags non authorized program or system equipment modificati
38. ltraje linear panel trasero 6 con opciones de voltaje de disparo de 12V 4 enchufes con filtraje linear con filtraje ultras nico adicional para componentes digitales o de video 2 con opci n de voltaje de disparo de 12V Dimensiones 4 H x 17 W x 14 75 D 10 16cm H x 43cm W x 38cm D 2 espacios de rack sin patas de goma Peso 14lbs 6 3kg 26 FURMAN 1690 Corporate Circle e Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com E15DMi_Rev4d
39. man No garantiza contra da os y defectos que se presenten por un uso anormal o impropio o por manejo del producto contra defectos o da os que se presenten por una instalaci n inapropiada contra defectos en productos o componentes no manufacturados por Furman o contra da os resultantes de productos o componentes no hechos para Furman o de Furman Esta garant a puede ser cancelada por Furman a su discreci n si el producto es modificado de alguna manera sin autorizaci n escrita por Furman Esta garant a tambi n no aplicar a productos sobre los cuales las reparaciones se hayan hecho o hayan sido realizadas por personas que no han sido autorizadas por Furman de manera escrita wd m 4 v gt Z e LA GARANT A ES EXCLUSIVA La nica y exclusiva obligaci n de Furman ser reparar o reponer el producto defectuoso en la manera y por el periodo descrito anteriormente Furman no tendr ninguna otra obligaci n con respecto a este producto o cualquiera de sus partes si est basado en contrato agravio responsabilidad terminante o de otra manera Bajo ninguna circunstancia si est basado en esta garant a limitada o de otra manera Furman no esta obligado por da os incidentales especiales o consecuentes Las declaraciones o acuerdos orales o escritos con empleados o representantes de Furman NO CONSTITUYEN GARANT AS no ser confiado por el comprador y no son parte del contrato de venta o de esta garant a limitada Esta garant
40. motocyclette ou un chargeur de batterie de voiturette de golf utiliser l int rieur et dans un endroit sec seulement Toutes les garanties contenues dans les pr sentes seront nulles et sans effet si le produit est utilis de quelque facon que ce soit avec tout appareil susmentionn TU E gt z N Vu CETTE GRANTIE REMPLACE TOUTES LES AUTRES GARANTIES EXPRESSES OU IMPLICITES Y COMPRIS MAIS SANS S Y LIMITER TOUTES LES GARANTIES IMPLICITES DE COMMERCIABILIT ET DE CONFORMIT A UN USAGE PARTICULIER La garantie de Furman ne couvre pas les dommages ou d fauts r sultant d un usage ou d une manipulation inappropri e ou anormale du produit les dommages ou d fauts r sultant d une installation inad quate les d fauts d un produit ou de composants non fabriqu s par Furman les dommages r sultant de l utilisation de produits ou de composants non fabriqu s par Furman Furman se r serve le droit d annuler cette garantie dans l ventualit o le produit a t modifi de quelque facon que ce soit sans l autorisation crite de Furman De plus cette garantie ne s applique pas aux produits qui ont t alt r s ou r par s par des personnes autre que celles dont il est fait mention dans l autorisation crite de Furman CETTE GARANTIE EST EXCLUSIVE l obligation exclusive de Furman consiste r parer ou remplacer le produit d fectueux de la facon et pendant la p riode susmentionn es Furman n a aucune autre obligati
41. oltaje y Corriente de grado de laboratorio Circuitos de protecci n contra contaminaci n de tierra cero que protege excelentemente componentes digitales Voltaje de 12V disparable para control remoto Introduccion Por m s de 34 a os Furman ha sido pionero en el desarrollo de productos de alimentaci n de AC para los m s demandantes profesionales de broadcast audio y video Aunque la necesidad de optimizar la alimentaci n de AC no es algo nuevo la tecnolog a del Elite 15 DM i y su nica implementaci n son revolucionarias y sin par Las extremas demandas de AC que encontramos en el mundo profesional del audio y video han requerido desarrollos tecnol gicos que van muchos m s all de los productos que t picamente encontramos en aplicaciones caseras de cine en casa o audio filos En estudios sonido en vivo radio y televisi n las interrupciones de alimentaci n son inaceptables Un equipo que falla o que tiene un desempe o pobre es costoso Lo mismo aplica para los cines en casa de hoy Nuestra soluci n se basa en la tecnolog a una extensa experiencia en ingenier a y una calidad de construcci n robusta que ha contestado al desaf o de trabajar con las contaminadas l neas de alimentaci n de hoy d a y que han conducido a la creaci n del Elite 15 DM i Las l neas de alimentaci n de hoy d a est n plagadas de ruido de RF Radio Frecuencia e IEM Interferencia Electro Magn tica Cuando conectas equipo sensible a las term
42. on or alteration Do not use this product in anyway with a generator heater sump pump water related device life support device medical device automobile motorcycle or golf cart battery charger To be used indoors only and in dry areas All warranties contained herein are null and void if used in anyway with any of the aforementioned devices THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Furman does not warrant against damages or defects arising out of improper or abnormal use or handling of the product against defects or damages arising from improper installation against defects in products or components not manufactured by Furman or against 8 damages resulting from such non Furman made products or components This warranty shall be cancelable by Furman at its sole discretion if the product is modified in any way without written authorization from Furman This warranty also does not apply to products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Furman m z 2 a n r THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Furman shall be to repair or replace the defective product in the manner and for the period provided above Furman shall not have any other obligation with respect to this product or any part thereof whether
43. on relativement ce produit ou toute pi ce de celui ci qu elle soit bas e sur le contrat la n gligence la responsabilit stricte ou autre En aucun cas que ce soit en vertu de cette garantie limit e ou autre Furman ne sera responsable des dommages cons cutifs sp ciaux ou indirects TOUT NONC ORAL OU CRIT de la part des employ s ou des repr sentants de Furman NE CONSTITUE PAS UNE GARANTIE ne doit pas tre pris en compte par l acheteur et ne fait pas partie du contrat de vente ou de cette garantie limit e Cette garantie limit e expose l int gralit de l obligation de Furman relativement au produit Si une partie de cette garantie limit e est jug e nulle ou ill gale le reste demeure en vigueur Les demandes en vertu de la garantie devraient tre accompagn es 17 FURMA EurE 15 DM i Guipe DE L UTILISATEUR d une copie de la facture originale indiquant la date d achat sauf dans le cas o un Enregistrement de garantie Warranty Registration a t compl t en postant une fiche de garantie la suite de l achat ou le produit a t enregistr en ligne Avant de retourner tout quipement aux fins de r paration veuillez vous assurer qu il est ad quatement emball et prot g contre les dommages pouvant survenir en cours de transport et qu il est assur 18 Sp cifications A Capacit de courant c a Entr e intensit de 15 A requise Sortie intensit efficace de 11 15 A maximum toutes les
44. otre syst me offre un son et des images d une grande clart et d une extr me pr cision Vos pr sentations vid o seront plus nettes et leurs couleurs plus r alistes gr ce une meilleure d finition des niveaux de gris et de noir et elles pr senteront une profondeur et une clart grandement am lior es Beaucoup d avanc es technologiques jusqu ici int gr es notre gamme vedette de Conditionneurs Reference sont devenues des caract ristiques fondamentales de la s rie Elite Maintenant les avantages que procurent la puret sans pr c dent au niveau de l alimentation et la protection in dite contre les surtensions sont la port e de tous 12 Installation Rs D ballage Avant d ouvrir l emballage de votre unit inspectez ce dernier de fa on a rep rer tout dommage vident et important ayant t caus la bo te et aux mat riaux de protection internes S il s av re vident que le contenu de la bo te a t endommag contactez le transporteur qui a livr l unit avant d ouvrir l emballage Si apr s avoir ouvert l emballage vous constatez que des dommages sont survenus en cours de transport contactez le transporteur Conservez tous les mat riaux d emballage et d exp dition Vous en aurez besoin dans l ventualit d un retour de l unit l usine aux fins de r paration La bo te devrait contenir l unit Elite 15 DM i un kit de montage en b ti un guide d utilisation et une fiche d enregistrement et de ga
45. our exclusive ground contamination free technology This aids in eliminating audio buzzing and the video hum bars that can result from typical in line suppressors Further our cable and satellite suppressors are DVR friendly as well as HD digital television ready Both DC carrier signals as well as high bandwidth signals can pass through our circuit In fact the bandwidth is less than 0 1dB loss at 1GHz To connect your cabling to these in line protectors simply follow the in and out indications marked next to the Telco Cable and Satellite connectors Note It is not possible to make an in line cable or satellite protector maintenance free as we have accomplished with the 120 VAC line This would necessitate limited signal bandwidth that would not allow the signal to pass Under extreme conditions it is possible that the surge suppression in one of these devices could sacrifice itself after a catastrophic event If the telephone cable or satellite signal will no longer pass through our protector please contact your local service representative installer or Furman for servicing Since these circuits are modular replacement may be accomplished in seconds with a new TVSS module To test this simply disconnect the incoming and out going cable from the Elite 15 DM i Connect the incoming connector to the component that formerly received the out going connector thus by passing the in line protection If the signal is present but not when used wit
46. plee el Elite 15 DM i notara una claridad e imponente enfoque del sonido y las im genes visuales de su sistema Las presentaciones de video ser n realmente coloridas y reales con una gran definici n en la escala de grises y negros adem s de un notable mejoramiento en la profundidad y claridad Muchos de los avances tecnol gicos previamente disponibles solo en nuestros Acondicionadores Insignia Reference son piedra angular de la serie Elite Ahora podr s beneficiarte de esta purificaci n de alimentaci n sin rival y la inigualable supresi n de picos Instalacion mM Desempaque Antes de desempacar su unidad inspeccione el cart n por cualquier da o severo obvio en la caja y o en los materiales internos de protecci n Si hay un probable da o interno contacte al transportista que entrego la unidad antes de desempacarlo Si despu s de desempacarlo un da o por el env o es evidente contacte al transportista Guarde y conserve todos los materiales de empaquetado y env o ya que los necesitar si tiene que regresar la unidad a la f brica por servicio 20 La caja debe de contener una unidad de Elite 15 DM i un kit de montaje en rack manual de usuario y garantia Si algo de lo anterior falta por favor contacte al centro de servicio al cliente de Furman Llene complete y regrese la garantia El registro se recomienda porque se puede usar para establecer si la unidad esta dentro del periodo de garant a a n cuando sus documentos origina
47. produits par les suppresseurs en ligne ordinaires De plus nos suppresseurs pour lignes coaxiales de c blodistribution et lignes de signaux par satellite sont compatibles avec les syst mes d enregistrement vid o num rique DV R et sont pr ts pour la t l vision haute d finition num rique Autant les signaux de porteuse que les signaux en bande large sont pris en charge par notre circuit En fait la perte au niveau de la bande passante est de moins de 0 1 dB 1 GHz Pour brancher vos c bles ces dispositifs de protection en ligne il vous suffit de suivre les indications in et out indiqu es c t des connecteurs Telco Cable et Satellite Remarque il est impossible d obtenir un circuit de protection en ligne sans entretien pour lignes coaxiales de c blodistribution et lignes de signaux par satellite comme nous l avons fait pour les mod les de 120 V c a Cela n cessiterait une largeur de bande r duite ne permettant pas la transmission du signal Sous des conditions extr mes il est possible que la suppression de la surtension d un de ces dispositifs soit sacrifi e la suite d un v nement catastrophique Si les lignes t l phoniques les lignes coaxiales de c blodistribution etles lignes de signaux par satellite ne sont plus prot g es veuillez contacter le repr sentant de votre r gion votre installateur ou Furman aux fins de r paration Puisque ces circuits sont modulaires leur remplacement par un module TVSS peut s effec
48. rantie S il manque un de ces l ments veuillez contacter le service la client le de Furman Compl tez et retournez votre fiche d enregistrement et de garantie L enregistrement est recommand et nous permet de d terminer si l unit est sous garantie dans l ventualit de la perte de vos documents de propri t originaux en plus de nous permettre de vous informer des mises niveau ou de vous transmettre d autres renseignements importants m E gt z N Fal Information sur la s curit et avertissements Veuillez lire et appliquer toutes les consignes de s curit et d utilisation avant d installer votre Elite 15 DM i Conservez ces instructions aux fins de r f rence ult rieure e Il est interdit de d monter ou de modifier l unit par quelque moyen que ce soit Cette unit ne renferme aucune pi ce rempla able par l utilisateur Vous devez conserver l unit dans un endroit sec et la prot ger contre l humidit excessive Vous devez pr venir la p n tration de liquides ou de corps trangers dans l unit Votre Elite 15 DM i devrait tre r par par un technicien de service qualifi dans les cas suivants Le cordon d alimentation ou la fiche a t effiloch e ou coup e Un corps tranger ou un liquide a p n tr l int rieur de l unit e l unit Elite 15 DM i a t expos e la pluie ou l humidit e l unit Elite 15 DM i semble ne pas fonctionner normalement ou sa performan
49. rman shall at its own expense furnish a replacement product or at Furman s option repair the defective product Return shipping charges back to purchaser will be paid by Furman CONNECTED EQUIPMENT WARRANTY Furman Sound s Connected Equipment Warranty covers equipment that is damaged by transient voltage an Occurrence while properly connected through the Furman Elite 15 DM i to a properly wired AC power line with a protective ground in an indoor location Furman s Connected Equipment Warranty is limited to the amount of the deductible on the Purchaser s personal property insurance policy up to 500 00 In order to make a claim for this Connected Equipment Warranty the Purchaser must forward a copy of his her personal property insurance claim for the damaged equipment to Furman and complete the Furman Connected Equipment Warranty claim form call Furman at 707 763 1010 to obtain the form Furman reserves the right to review the damaged Furman product the damaged connected equipment and the site where the damage occurred All cost of shipping damaged equipment to Furman for inspection shall be borne solely by the Purchaser Damaged equipment must remain available for inspection until the claim is finalized The Connected Equipment Warranty is also in effect for a period of three years unless the Purchaser does not complete the warranty registration within fifteen days from date of purchase at which time the Connected Equipment Warranty period is a
50. s 12V de disparo m s adelante abajo Conectando componentes a las terminales de AC con Filtraje Linear El Elite 15 DM i tiene enchufes de AC en la parte trasera y en el panel frontal denominadas Audio Audio Video que se emplear n para conectar los componentes no conectados en los enchufes de AC de Video Componentes Estos enchufes a n 21 FURMA ELITE 15 DM i MANUAL DE USUARIO poseen un excepcional filtraje de ruido de AC para maximizar el desempe o del sistema Refi rase a la explicaci n de los 12V de disparo m s adelante abajo Voltaje de 12V disparado Interruptor El Elite 15 DM i posee un enchufe frontal y 4 en la parte trasera que siempre est n encendidos una vez que el interruptor de alimentaci n frontal sea encendido Los 8 enchufes en la parte trasera restantes etiquetados como switched requieren un dispositivo que dispare un voltaje de 12V tales como los t picamente encontrados en muchos receptores y pre amplificadores de audio La entrada para los 12V de disparo es un mini jack mono hembra Un producto adicional tal como un subwoofer remoto puede ser conectado en cadena Daisy chained de la salida de 12V para manejar una unidad m s controlada por disparo Para aquellos que no quieran utilizar el voltaje de disparo de 12V un conveniente bot n de bypass esta localizado adyacente alos jacks de entrada y salida Presionando este bot n todos los enchufes operar n cuando el interruptor de alimenta
51. thin the warranty period should your original ownership documents be lost and it assists us in informing you about upgrades or other vital information m z 2 n r Safety Information Warnings Please read and observe all of the safety and operating instructions before the Elite 15 DM i is operated Retain these instructions for future reference Do not disassemble or modify in any way No user serviceable parts inside Keep away from moisture and avoid excessive humidity Do not allow liquids or foreign objects to enter the unit The Elite 15 DM i should be serviced by qualified service personnel when The power supply cord or plug has been frayed or cut Objects have fallen or liquid has spilled into the unit The Elite 15 DM i has been exposed to rain or other moisture The Elite 15 DM i does not appear to operate normally or exhibits a marked change in performance e The Elite 15 DM i has been dropped or the enclosure damaged The Elite 15 DM i requires that a safety ground be present for proper operation Power Source The power source to which the Elite 15 DM i is connected should be adequate for use at 15 Amps The Elite 15 DM i will operate with a10 Amp service outlet however nuisance tripping at the circuit breaker panel may result if the systems continuous current draw exceeds 10 Amps Placement The Elite 15 DM i is manufactured with four rubber feet for placement on any table cabinet shelf or f
52. tuer en quelques secondes Pour tester cette situation il vous suffit de d brancher le c ble avec connecteurs d entr e et de sortie de l unit Elite 15 DM i Branchez le connecteur d entr e sur le composant qui recevait pr c demment le connecteur de sortie de facon outrepasser le circuit de protection en ligne S il y a pr sence du signal alors qu il n y en avait pas en utilisant l unit Elite 15 DM 1 cela signifie que le circuit de protection est endommag en supposant qu il fonctionnait normalement avant l orage ou l v nement catastrophique Garantie NN Furman Sound LLC garantit l acheteur original de l unit Furman Elite 15i que ce produit sera exempt de tout d faut de mat riel et de fabrication pendant une p riode de trois ans compter de la date d achat L acheteur de ce produit a quinze jours compter de la date d achat pour compl ter par Internet sur le site Web de Furman ou par la poste l enregistrement dudit produit aux fins de garantie faute de quoi l acheteur verra sa p riode de garantie r duite un an compter de la date d achat Advenant que le produit ne fonctionne pas tel que sp cifi ci dessus au cours de la p riode de garantie limit e l acheteur doit informer Furman par crit des pr tendus d fauts Si le type et la nature des d fauts sont couverts par la pr sente garantie Furman autorisera l acheteur retourner le produit l usine Furman ou un centre de r paration autoris de F
53. urman Les demandes au titre de la garantie devraient tre accompagn es d une copie de la facture originale indiquant la date d achat sauf dans le cas o un Enregistrement de garantie Warranty Registration a t compl t en postant une fiche de garantie d ment remplie ou en ligne par le biais du site Web de Furman Les frais d exp dition l usine Furman ou un centre de r paration autoris de Furman sont assum s l avance par l acheteur du produit Furman s engage fournir ses frais un produit de remplacement ou sa seule discr tion r parer le produit d fectueux Les frais d exp dition aux fins de retour l acheteur seront assum s par Furman 16 GARANTIE COUVRANT L QUIPEMENT CONNECT la garantie de Furman Sound concernant l quipement connect couvre l quipement endommag par la tension transitoire un v nement alors qu il est ad quatement connect par l entremise de l unit Furman Elite 15i une ligne d alimentation c a correctement c bl e avec une mise la terre l int rieur d un lieu La garantie de Furman Sound couvrant l quipement connect est limit e au montant de la franchise pr vue la police d assurance de biens meubles de l Acheteur jusqu concurrence de 500 Pour toute demande au titre de cette garantie couvrant l quipement connect l Acheteur doit envoyer Furman une copie de sa demande de r clamation au titre de son assurance de biens meubles relativement
Download Pdf Manuals