Home

electric wall oven installation instructions

image

Contents

1. Front view Wall Oven Side view a WITH GAS COOKTOP ABOVE Figure 13 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN Right Side of Cabinet To be accessible for shut off valve operation ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS 7 Checking Operation Your model is equipped with an Electronic Oven Control Each of the functions has been factory checked before shipping However it is suggested that you verify the operation of the electronic oven controls once more Refer to the Use and Care Guide or the Timer Guide for operation 1 Remove all items from the inside of the oven 2 Turn on the power to the oven Refer to your Use amp Care Guide 3 Verify the operation of the electronic oven controls Bake Verify that this function makes the oven hot 20 seconds after turning oven on open the door and you should feel heat coming from the oven Broil When the oven is set to BROIL the upper element in the oven should become red Convection When the oven is set for a convection baking or roasting both elements cycle on and off alternately and the convection fan will run The convection fan will stop running when the oven door is opened Before You Call for Service Read the Before You Call for Service Checklist and the Operating Instructions in your Use and Care G
2. I AVERTISSEMENT Pour r duire les risques de blessures et pour emp cher le four encastr de basculer Utilisez les supports de fixation pour retenir le four encastr l armoire 36 Min 91 4 cm Min 208 240 Volt bo te de jonction pour le four encastr Utilisez un contre plaqu de 34 1 9 cm d paisseur mont sur deux solives et galit avec le coup de pied La base doit pouvoir supporter 200 lbs 90 kg D coupez une ouverture pour la 11 5 cm Max sortie du c ble arm de l appareil vers la bo te de jonction DIMENSIONS DE L OUVERTURE F LARGEUR G PROFONDEUR HAUTEUR 30 76 2 cm 28 1 2 72 4 cm Min 28 Va 71 8 cm Min Wall Oven 29 73 7 cm Max 24 61 cm Min 28 7 8 73 3 cm Max Figure 12 INSTALLATION TYPIQUE D UN FOUR ENCASTR SIMPLE SOUS LE COMPTOIR AVEC UNE TABLE DE CUISSON LECTRIQUE OU GAZ INSTALL E PAR DESSUS 25 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE i 18 45 7 cm Max TABLE DE CUISSON GAZ Ad lle 4 10 5 Max 6 1 2 Min 12 7 cm 16 5 cm 0 E Prise 120V 60Hz mise a la terre C t droit de Conduit a gaz flexible l armoire Acc s facile pour fermer la robinet Y R gulateur Y de pression C t s de l armoire ou panneau de Robinet de fermet
3. Figura 2 Para horno sencillo ver la figura 1 DIMENSIONES DEL APARATO MODELO A Exterior posterior Horno de pared 30 eden 23 018 DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO min com min 1 24 61 30 76 2 Min Horno de pared 30 76 2 cm 28 2 72 4 29 73 7 saan 59 299 300621 10085 las dimensiones se dan en pulgadas cm INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED Notas importantes para el instalador 1 Lea todas las instrucciones contenidas en este manual antes de instalar el horno 2 Saque todo el material usado en el embalaje del compartimiento del horno antes de conectar el suministro el ctrico o de gas a la estufa Observe todos los c digos y reglamentos pertinentes Deje estas instrucciones con el consumidor ESTOS HORNOS NO SON APROBADOS PARA LA INSTALACI N APILABLE O DE LADO A LADO w Nota importante al consumidor Conserve estas instrucciones y el manual del usuario para referencia futura INSTRUCCIONES IMPORTANTES DE SEGURIDAD e Asegurese de que su horno de pared sea instalado y puesto a tierra de forma apropiada por un instalador calificado o por un t cnico de servicio e Su horno de pared debe ser el ctricamente puesto a tierra de acuerdo con los c digos locales o en su ausencia con el C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n en los Estados Unidos o el Codigo El ctrico Cana
4. 1 1 1 1 Brackets Single Oven see Fig 1 Single Oven Double Oven see Fig 2 23 1 4 59 1 cm Double Oven 46 2 118 1 cm 1 1 1 Mounting 1 bracket installed in cabinet Oven Bracket 1 2 Cabinet o Figure 8 Oven Mounting 3 Insert the unit into the cabinet opening Slide unit inward bracket released leaving 3 7 6 cm clearance between the oven and Right i Oven removed from 00 front of cabinet Figure 9 Pull the armored cable the cabinet through the hole in the floor and toward the junction box while moving the appliance inward 4 Install now the bottom trim using the screws supplied withthe unit Figure 10 5 Push the unit in and against the cabinet then the oven side bracket will clip in the one you just install on the side of the cabinet opening supplied To pull out the oven for servicing insert the tool supplied with the appliance both side at the same time in the hole located on the side frame and visible when the door is opened After inserting the tool pull the oven towards you see figure 11 6 For typical under counter installation of an electric built in oven see Figures 12 and 13 Hole where to insert the tool Figure 11 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS Only certain cooktop models may be installed over certain built in electric oven models Approved cooktops and built in ovens are l
5. IMPORTANT SAFETY INSTRUCTIONS Be sure your wall oven is installed and grounded properly by a qualified installer or service technician Your wall oven must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition in United Sates or with CSA Standard C22 1 Canadian Electrical Code Part 1 in Canada PNA Stepping leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven Never use your wall oven for warming or heating the room Prolonged use of the wall oven without adequate ventilation can be dangerous The electrical power to the oven must be shut off while line connections are being made Failure to do so could result in serious injury or death 1 Carpentry Refer to figure 1 or 2 for the dimensions applicable to your appliance and the space necessary to receive the oven The oven support surface may be solid plywood or similar material however the surface must be level from side to side and from front to rear 2 Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the
6. La placa de serie est ubicada aqu La placa a serie esta S ubicada aqu 3 Conexi n el ctrica El usuario tiene la responsabilidad personal y obligaci n de utilizar un instalador calificado para asegurar que la instalaci n el ctrica est hacha de forma adecuada y est conforme con el C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n en los Estados Unidos o el C digo El ctrico Canadiense CSA Standard C22 1 Part 1 en Canad En este electrodomestico se necesita un cable de toma a tierra Este electrodom stico viene equipado con un cable de conexi n de cobre Si esto tuviera que conectarse a los cables de aluminio de una casa use solamente los conectores especiales aprobados para empalmes de cobre y aluminio de acuerdo con el C digo El ctrico Nacional y los reglamentos y c digos locales Este electrodom stico se ha fabricado con un cable para el suministro de energ a que tiene un alambre neutro de color blanco y un alambre pelado de toma a tierra conectado al armaz n 1 Silos c digos locales permiten la conexi n del conductor de toma a tierra del armaz n al neutro alambre blanco Una el alambre pelado y el alambre blanco del cable de suministro de energ a del electrodomestico juntos al cable neutro blanco en la caja de empalme Conecte los alambres restantes desde el cable de suministro de energ a emparejando los colores con los de los cables en la caja de empalme Fi
7. Observez tous les codes et r glements applicables Assurez vous de laisser ces instructions au consommateur 5 CES FOURS NE SONT PAS HOMOLOGU S POUR UNE INSTALLATION COTE A COTE OU SUPERPOSEE Consommateur Conservez ces instructions avec votre Manuel d utilisation et d entretien pour r f rences futures DIRECTIVES IMPORTANTES DE SECURITE Assurez vous que votre four encastr est install et mis la terre conform ment par un installateur ou un technicien de service qualifi e Votre four encastr doit tre mis la terre conform ment aux codes locaux d lectricit ou en l absence de codes en conformit avec le National Electrical Code ANSI NFA No 70 derni re dition aux Etats Unis ou avec la norme ACNOR C22 1 Partie 1 au Canada Grimper s appuyer ou s asseoir sur la porte de ce four encastr peut entra ner des blessures graves et peut aussi causer des dommages au four encastr N utilisez jamais le four encastr pour chauffer ou r chauffer la pi ce L utilisation prolong e du four encastr sans ventilation ad quate peut tre dangereuse Il faut couper l alimentation lectrique durant le montage des connexions lectriques d faut de ce faire il peut en r sulter des blessures graves ou la mort 1 Travaux de menuiserie Reportez vous la figure 1 ou 2 pour tablir quelles sont les dimensions applicables votre mod le ainsi que l espace n cessaire pour recevoir l app
8. la terre ou un connecteur de mise la terre qui doit tre branch la borne ou au fil de mise la terre de l appareil e N utilisez pas un tuyau d alimentation de gaz pour la mise la terre de l appareil WJ Si vous ne respectez pas toutes les instructions pr c dentes un feu des blessures corporelles ou un choc lectrique peuvent en r sulter INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE Par temps froid pour prot ger la commande du four il faut attendre au moins trois 3 heures apr s sa r ception avant de mettre l appareil sous tension Ceci vitera toute possibilit d endommager la commande du four lors de la mise sous tension Emplacement des num ros de mod le et de s rie La plaque signal tique est situ e sur le c t int rieur de la moulure lat rale Pour toute commande de pi ces ou demande de renseignement au sujet de votre appareil assurez vous d inclure le num ro de mod le et de s rie ainsi que le num ro ou lettre de lot de la plaque signal tique de votre four Emplacement de la plaque de s rie Emplacement de la plaque de s rie 3 Connexions lectriques Le consommateur est responsable et doit communiquer avec un installateur qualifi pour s assurer que l installation lectrique est ad quate et conforme avec le National Electrical Code ANSI NFPA No 70 derni re dition ou avec la norme ACNOR C22 1 partie 1 du code c
9. de la porte soulevez l g rement la porte et tirez la vers vous pour d gager les supports de charni res Continuez tirer la porte vers vous en faisant pivoter le haut de la porte vers l appareil de fa on d gager les bras des charni res Pour remettre la porte en place proc dez l inverse Assurez vous que les supports des charni res sont bien engag s avant de lib rer les bras des charni res NOTE La porte du four est tr s lourde Assurez vous de l agripper fermement avant de la soulever hors des fentes des charni res Faites attention lorsque que la porte est enlev e N tendez pas la porte sur sa poign e Cela pourrait lui causer des dommages ou la briser Loquet en position engag e permettant le retrait Figure 6 Loquet en position normale Figure 5 Figure 7 FENTES DES CHARNI RES porte compl tement d gag e de l appareil 5 Enlever la moulure inf rieure Enlevez la moulure inf rieure qui est coll e sur le dessus de l appareil Cette derni re sera install e plus tard INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE Installation dans l armoire Risque de lourde charge Soyez 2 personnes ou plus pour installer ou d placer l appareil Des blessures ou des dommages l appareil peuvent survenir si vous ne suivez pas cette instruction Le four encastr peut basculer quand la porte est ouverte Il faut donc le fixer l
10. NOTE Le calibre des fils et leurs connexions doivent tre conformes la capacit des fusibles et la capacit nominale de l appareil selon le National Electrical Code ANSI NFPA No 70 derni re dition ou selon la norme ACNOR 22 1 Partie 1 du Code canadien de l lectricit et les codes et les r glements locaux Bud N utilisez pas de rallonge lectrique avec cet appareil Son utilisation peut causer un feu un choc lectrique ou des blessures corporelles 2 Il faut brancher l appareil au panneau de distributions en utilisant des c bles flexibles gaine m tallique ou non m tallique On doit brancher directement la bo te de jonction le c ble gain flexible de l appareil faut disposer la bo te de jonction tel qu illustr la Figure 1 ou 2 en laissant autant de l che que possible dans le c ble entre la bo te et l appareil pour en faciliter le d placement si l entretien s av re n cessaire Une attache de protection s curitaire doit retenir le c ble arm flexible la bo te de jonction A AVERTISSEMENT Risque de choc lectrique e La mise a la terre de cet appareil est obligatoire Ne branchez pas l appareil au circuit lectrique tant qu il ne sera pas mis la terre correctement et en permanence e Coupez l alimentation la bo te de jonction avant de faire les raccords lectriques Cet appareil doit tre connect un circuit permanent lectrique m tallique et mis
11. r tissage par convection les deux l ments cyclent et le ventilateur convection situ l arri re tourne Le ventilateur convection arr te lorsque l on ouvre la porte du four 27 Avant d appeler le service d entretien R viser la liste de v rifications pr ventives et les instructions d op ration dans votre Manuel d utilisation et d entretien Vous sauverez probablement du temps et de l argent La liste contient les incidents ordinaires ne r sultant pas de d fectuosit s dans le mat riel ou la fabrication de cet appareil Pour obtenir notre adresse et notre num ro de t l phone sans frais r f rez vous votre Manuel d utilisation et d entretien INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE Notes Notas 28
12. see note a Suggested distance from floor is 31 78 7 cm A X Electrical Minimum required distance is 4 2 11 4 N Junction Box Bottom edge not supplied cm must be finish cut with unit NOTE For combination of this Built in Oven with Warm amp Serve Drawer see cutout dimensions specified in the Warm amp Serve Drawer Installation Instructions Figure 1 Double Wall Oven see page 2 PRODUCT DIMENSIONS 30 76 2 cm Wall Oven 30 76 2 29 74 2 28 71 5 245 62 5 CUTOUT DIMENSIONS AND CABINET WIDTH 30 76 2 cm Wall Oven 28 2 72 4 29 73 7 24 61 2874 71 8 287 73 3 All dimensions are in inches cm P N 318201524 0709 Rev C English pages 1 8 Espa ol p ginas 9 16 Printed in United States Fran ais pages 17 24 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS PIN Do not remove spacers on the side walls and or on the back of the built in oven These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire NOTE 1 Base must be capable of supporting 400 pounds 181 4 kg 2 Make sure base is level and front of cabinet is square If the cabinet base is not level the oven glides will tend to slide out 2 when opening the door NOTE Allow at least 23 59 1 cm K clearance for door depth when it is open NOTE Dimension G is critical to th
13. 4 C ble d alimentation Fil blanc Fil d nud ou vert Connecteur homologu U L ou ACNOR C ble de l appareil Bo te de jonction Figure 4 BO TE DE JONCTION 4 FILS MISE LA TERRE Si la connexion a t faite en utilisant un syst me lectrique 4 fils le ch ssis de l appareil NE DOIT PAS tre branch au fil neutre du c ble 4 fils LECTRICIEN Le c ble gain fourni avec cet appareil est homologu par l ACNOR pour connexion des circuits r sidentiels de fils de calibre sup rieur La capacit thermique de l isolant des c bles exc de consid rablement celle des circuits r sidentiels La transmission du courant lectrique maximum permise des fils du c ble est fonction de la capacit thermique de la gaine plut t que du calibre du fil IMPORTANT Ne soulevez pas le four encastr par la poign e de la porte 23 4 Enlever la porte du four Enlever les portes pour r duire le poids de l appareil et ainsi faciliter sa manipulation et son installation IMPORTANT Ne soulevez pas la porte du four par la poign e Suivre les instructions suivantes pour enlever la porte du four 1 Ouvrez compl tement la porte 2 Soulevez les loquets mobiles situ s sur chaque charni re vers le devant de l appareil se peut qu il soit n cessaire d exercer une l g re pression sur les loquets mobiles pour les soulever 3 Avec une main de chaque c t
14. 4 4 WIRE GROUNDED JUNCTION BOX Junction Box If connecting to a 4 wire electrical system the appliance frame MUST NOT be connected to the neutral wire of the 4 wire electrical system NOTE TO ELECTRICIAN The armored cable leads supplied with the appliance are CSA recognized for connection to larger gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone 4 Remove the oven door Remove the doors to reduce the weight of the appliance and to facilitate its handling and its installation IMPORTANT Do not lift the oven by the door handle To remove the oven door see following steps 1 Open the door to the fully opened position Figure 5 2 Pull up the lock located on each hinge toward the front of range You may have to apply a little upward pressure on the lock to pull it up Figure 6 3 Grasp the door by the sides pull the bottom of the door up and toward you to disengage the hinge supports Keep pulling the bottom of the door toward you while rotating the top of the door toward the appliance to completely disengage the hinge levers Figure 7 4 Proceed in reverse to replace the oven door Make sure the hinge supports are fully engaged before unlocking the hinge levers NOTE The o
15. d aluminium en suivant bien attentivement les directives recommand es par le fabricant Mise la terre du ch ssis au neutre Si l appareil est utilis dans une maison mobile un nouveau branchement 1996 NEC un v hicule r cr atif ou si les codes locaux n autorisent pas la connexion du conducteur de mise la terre du ch ssis au neutre r f rez vous la figure 4 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE 2 Si l appareil est utilis dans une maison mobile ou si les codes locaux N AUTORISENT PAS une connexion du conducteur de mise la terre du ch ssis au neutre blanc s parez le fil blanc du fil d nud en cuivre de mise la terre du c ble d alimentation de l appareil Raccordez le fil blanc du c ble d alimentation de l appareil au fil blanc de la bo te de jonction Connectez les fils rouge et noir du cable d alimentation au fil de couleur correspondante dans la bo te de jonction Le fil d nud doit tre utilis pour la mise terre de l appareil en accord avec les normes lectriques locales applicables Connectez le fil d nud en cuivre de mise la terre au fil de mise la terre du panneau principal NE connectez pas le fil de mise la terre un tuyau d alimentation de gaz Ne branchez pas l appareil au circuit lectrique avant qu il soit mis a la terre correctement en permanence Branchez le conducteur de mise a la terre avant de mettre l appareil sous tension Figure
16. horno Quite las puertas para reducir el peso del aparato y para facilitar su manejo y su instalaci n IMPORTANTE No levante el horno por la manija de la puerta NOTA La puerta del horno es muy pesada Aseg rese que usted tiene un pu o firme antes de levantar la puerta de horno de las bisagras Tener Cuidado una vez la puerta se a quitado No coloque la puerta en su manija Esto podr a causar bollos o rasgu os Para remover la puerta del horno vea los siguientes pasos 1 Abra la puerta del horno por completo Figura 5 2 Devante el seguro de cada bisagra puede ser que tenga que presionar un poco para levantarlo Figura 6 3 Tome la puerta por los lados jale el fondo de la puerta hacia arriba y al frente para sacar los soportes de la bisagra Siga jalando hacia usted la puerta rotandala al mismo tiempo hacia la estufa para sacar por completo la bisagra Figura 7 Para ensamblarla de nuevo proceda a la inversa Aseg rese que los soportes de la bisagra esten completamente insertos antes de desactivar el seguro de la bisagra Seguro en posici n normal Seguro desactivado para sustraer la puerta Figure 6 Figure 7 Apertura de bisagra puerta desemsamblada de la estufa 5 Remueva el ajuste inferior Remueva el ajuste inferior de la parte superior de la unidad El ajuste debera ser instalado despu s INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED 6
17. las instrucciones mencionadas podria resultar en un incendio choque el ctrico o lesiones personales INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED No debe de utilizarse ningun tipo de extension con este electrodom stico Esto podria resultar en fuego choque el ctrico o lesiones personales 2 Estos electrodom sticos se deben conectar con la caja de fusibles desconectada o interruptor a trav s del cable flexible forrado armado o no met lico El cable armado flexible del electrodom stico se debe conectar directamente a la caja de emplames La caja de empalmes se debe situar seg n lo mostrado en el cuadro 1 y se debe dejar un tanto flojo el cable entre el electrodom stico y la Caja de manera que la unidad puede ser movida si es necesario darle mantenimiento 3 Se debe de proporcionar un retenedor de cable para unir el cable armado flexible a la caja de empalmes Durante la temporada de fr o y para prevenir todo da o a los controles del horno empotrado espere unas 3 horas antes de encenderlo Esto evitar todo da o posible al control incorporado del horno empotrado Ubicaci n del n mero de modelo y de serie La placa de serie se encuentra dentro del horno en el contramarco lateral Cuando haga pedidos de repuestos o solicite informaci n con respecto a su horno est siempre seguro de incluir el n mero de modelo y de serie y el n mero o letra del lote de la placa de serie de su horno
18. peut tre que peu ou pas de modification sera n cessaire INES N enlevez pas les entretoises sur les parois lat rales et ou l arri re du four Ces entretoises centrent le four dans l espace fourni Le four doit tre centr pour pr venir une accumulation excessive de chaleur pouvant causer un feu ou des dommages NOTE 1 La base doit pouvoir supporter 200 lbs 90 7 kg 2 Assurez vous que le fond du cabinet est bien a niveau et que la facade de l armoire est d querre Si le cabinet n est pas niveau les 8 Ouverture pour le glissi res des grilles auront tendance glisser cable arm hors du four lors de l ouverture de la porte NOTE Allouez au moins 23 59 1 cm d espace pour permettre l ouverture de la porte du four 3 7 6 cm Max Porte ouverte voir la note Bo te de Jonction pas fournie avec l appareil NOTE La dimension G est critique pour une bonne installation du four Si la moulure inf rieure ventilation du four ne s adapte pas contre l armoire ou si un bruit se fait Le bord du comptoir entendre sur les mod les convection doit tre bien coup v rifiez la dimension G pour vous assurer sans bavure qu elle est correcte 2 5 1 cm Min NOTE Pour l installation combin e de ce four encastr avec un tiroir r chaud r f rez vous aux dimensions de d coupage La distance sugg r e du
19. 0V 208V Menos de 4100W 4100W 6200W 8300W y 9600W y Table A Observe todos los c digos que gobiernan y ordenanzas locales 1 Un cable de 3 o 4 alambres monof sico 120 240 o 120 208 voltios 60 hertzios es la unica fuente el ctrica que requiere en un circuito separado en ambos lados de la l nea se recomienda un fusible o un interruptor de retraso de tiempo No funda a cable neutro Se debe de tener precaucion al combinar un horno de pared y una cubierta refierase a la placa de seria de cada uno de los aparatos NOTA Los tama os y las conexiones del alambre deben conformarse con el tama o del fusible y el grado de la aplicaci n de acuerdo con el c digo El ctrico Nacional Americano ANSI NFPA No 70 ultima edici n o con el est ndar CSA canadiense C22 1 c digo el ctrico canadiense parte 1 y c digos y ordenanzas locales ADVERTENCIA Riesgo de choque el ctrico Una puesta a tierra se require en este aparato No lo conecte a la corriente el ctrica hasta que el aparato haya sido puesto a tierra Desconecte la corriente el ctrica a la caja de empalmes antes de hacer la conexion el ctrica Este aparato debe estar conectado con un sistema de alambres puesto en tierra metalico y permanente o un conector de pueta a tierre debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato No utilice el suministro de gas para hacer la puesta a tierra La falta de cualquiera de
20. 2 and with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach the flexible armored cable to the junction box ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS A WARNING Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the junction box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance Do not use a gas supply line for grounding the appliance Failure to do any of the above could result in a fire personal injury or electrical shock During cold temperature weather to prevent damage to the oven control wait at least three 3 hours after receiving this built in oven before switching the power This will prevent possible damage to the built in oven control at power on Model and Serial Number Location The serial plate is located inside the oven on the side trim When ordering parts for or making inquires about your oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven Serial Plate Location locat
21. 5 7 cm Max ESTUFA DE GAS Lado derecho del gabinete te Tomacorriente puesto a tierra artefactos Adaptor de 120Voltios de gas 60Hz para tener Regulador valvula de Lados del ay presion cierre gabinete o panel manual llenador V lvula 4 Gabinete del horno de pared manual o ESTUFA DE GAS Vista anterior Vista de lado del horno de pared HN Figura 13 INSTALACION T PICA PARA UNA ESTUFA DE GAS ENCIMA DE UN HORNO DE PARED INSTALADO DEBAJO DEL MOSTRADOR INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED 7 Verificaci n del funcionamiento Su modelo est equipado con un Control Electr nico de Horno Cada una de las funciones ha sido controlada en f brica antes del despacho Sin embargo le sugerimos verificar el funcionamiento de los controles electr nicos una vez m s Consulte la Gu a de Uso y Cuidado o la Gu a del controles para ver el funcionamiento del horno 1 Extraer todos los elementos de la parte interior del horno 2 Encender el horno Consular la Gu a de Uso y Cuidado 3 Verificar el funcionamiento de los controles electr nicos del horno Hornear Verificar que esta funci n caliente el horno Veinte minutos despu s de encender el horno abrir la puerta y ver si se siente q
22. CIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED TOO no quite los separadores de los muros laterales o y de la parte posterior del horno empotrado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentraci n excesiva de calor que podr a resultar en da os por el calor o un incendio NOTA 1 La base debe poder sostener 400 libras 181 4 kg 22 2 Aseg rese que la base esta a nivel y que el frente del gabinete esta 6 4 cm cuadrado Si la base del gabineteno esta Min nivelada las correderas del horno tendera a deslizar en el momento que se abre la puerta A 0 NOTA Deje lo menos 2374 59 1 libre para la profundidad de la puerta cuan do esta abierta B NOTA La dimensi n G est primordial para instalar 5174 correctamente el horno pared Si el adorno del 130 2 cm H armazon del horno no topa contra el armario o si escuche un ruido verifique si la dimensi n G esta en conformidad con la dimensi n requerida 0 y 111 J 7 6 Puerta Abierta vea la nota A 29 21 cm 4 cm Max EN ae KR A Caja el trica El borde inferior de empalme debe ser cortado cuidadosamente no proporcionado Distancia sugerida desde el suelo es 1172 29 2 cm con la unidad La distancia minima requerida es 4 11 4 cm
23. ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below You may find little or no cabinet work will be necessary PAT Do not remove spacers the side walls and or on the back of the built in oven These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire NOTE 1 Base must be capable of supporting 200 pounds 90 7 kg 2 Make sure base is level and front of cabinet is square If the cabinet base is not level the oven glides will tend to slide out when opening the door Hole for NOTE Allow at least 23 59 1 cm clearance for door depth when it is open NOTE Dimension G is critical to the proper B installation of the built in oven If the oven decorative moulding does not butt against the cabinet or if noise is heard on convection models verify dimension G to assure it is according to the required dimension Door Open
24. Instalaci n del Gabinete Wi 10114 Peligro de Peso Pesado Use 2 personas o m s para mover e instalar el horno de pared e Si no cumple con esta instrucci n puede resultar en lesiones pesonales o da os al horno de pared ADVERTENCIA El horno de pared puede inclinarse cuando la puerta esta abierta Los soportes de montaje que vienen con el horno de pared deben de estar ajustados al armario y al aparato para evitar que el horno de pared se incline y ocasione quemaduras graves Instrucciones de instalaci n de los soportes de montaje 1 Encuentre los dos tornillos de montaje incluidos con el paquete de informaci n 2 Instale la abrazadera de montaje como en la figura 8 Nota Para prevenir cualquier tipo de da o al cabinete es recomendable perforar agujeros conn un diametro de 1 16 0 16cm antes de instalar los soportes F Horno sencillo ver Fig 1 Horno doble ver Fig 2 F Soportes a de montaje 1 pS L U H Horno sencillo ver Fig 1 Horno Sencillo Horno doble ver Fig 2 23 1 4 59 1 cm Horno Doble 46 2 118 1 cm Figura 8 3 Introduzca la unidad dentro de la apertura del gabinete Deslicela dejando 3 7 6 cm entre el horno y el frente del gabinete Figura 9 Empuje la unidad y tire el cable blindado a trav s del hoyo en el pi
25. X Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire Use only connectors designed for joining copper to aluminum and follow the manufacturer s recommended procedure closely ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS Frame grounded through the neutral If used in a mobile home new branch circuit 1996 NEC recreational vehicles or where local codes do not permit grounding through neutral see figure 4 2 If used in mobile homes or if local codes DO NOT permit connection of the frame grounding conductor to the neutral white wire separate the white and bare copper ground wires that extend out of the end of the supply cable of the appliance Connect the white wire from supply cable to the neutral white wire in the junction box Connect the black and red wires from the supply cable to the matching color wires in the junction box The bare wire must now be used to ground the appliance in accordance with local electrical codes Connect the bare copper ground wire to the grounded lead in the service panel DO NOT ground to a gas supply pipe DO NOT connect to electrical power supply until appliance is permanently grounded Connect the ground wire before turning on the power Figure 4 Cable from Power Supply Ground Wire White Wire Ground Wire Bare or Green L Wire ULL Listed Conduit Connector or CSA listed Cable from appliance Figure
26. anadien de l lectricit et les codes et r glements locaux La mise la terre de ces appareils est obligatoire Ces appareils sont munis d un c ble conducteur en cuivre flexible Si la connexion est faite un filage r sidentiel en aluminium utilisez seulement des connecteurs sp ciaux approuv s pour le raccord de fils en cuivre et des fils en aluminium conformes au National Electrical Code et aux codes et ordonnances locaux 22 Ces appareils sont fabriqu s avec un fil d alimentation neutre blanc et un fil d nud en cuivre de mise la terre connect au ch ssis 1 Siles codes locaux permettent la connexion du fil de mise la terre du ch ssis au neutre blanc Raccordez le fil de cuivre d nud et le fil blanc du cable d alimentation de l appareil ensemble et au fil neutre dans la bo te de jonction Raccordez les autres fils du c ble d alimentation selon leur couleur respective leur correspondant dans la bo te de jonction Figure 3 C ble d alimentation Fil d nud Fils rouges Bo te de jonction Fil blanc _ Connecteur homologu ou ACNOR C ble de l appareil Figure 3 BO TE DE JONCTION 3 FILS MISE LA TERRE Fil d nud ou vert La connexion inappropri e du circuit r sidentiel en aluminium des fils en cuivre peut entra ner un court circuit ou un feu N utilisez que des connecteurs con us pour joindre des fils de cuivre ceux
27. areil La surface qui supporte l appareil doit tre en contre plaqu solide ou tout autre mat riau du m me type Il faut vous assurer que la surface est de niveau d un c t l autre et de l avant l arri re 2 Exigences lectriques Cet appareil doit tre branch une alimentation poss dant la tension et la fr quence appropri es doit tre connect un seul circuit correctement mis la terre et prot g par un disjoncteur ou un fusible Pour savoir quel disjoncteur ou fusible utilis pour cet appareil r f rez vous a la plaque signal tique pour connaitre la consommation watts et avec cette donn e consultez la table A pour connaitre l amp rage requis du disjoncteur ou du fusible 21 Circuit de protection Calibre de Circuit de l appareil Watts protection 240V recommand Moins de 4800W 4800W 7200W 7200W 9600W 6200W 8300W 40A Table A Observez tous les r glements et les codes locaux applicables 1 Un c ble lectrique 3 ou 4 fils de 120 240 ou 120 208 Volt monophas 60 Hz CA est requis sur un circuit s par muni d un fusible sur chaque fil conducteur fusible temporis ou disjoncteur recommand NE RELIEZ PAS de fusible au neutre faut tenir compte de l ajout d une plaque de cuisson superpos e au four encastr R f rez vous la plaque signal tique de chaque unit Calibre de l appareil Watts 208V recommand Moins de 4100W 20A 4100W 6200W 30A
28. armoire l aide des supports de fixation fournis afin de pr venir le basculement du four et des blessures corporelles Instructions d installation des supports de fixation 1 R cup rez les 2 supports et les vis de fixation compris dans l emballage contenant la litt rature 2 Installez les supports de fixation tel qu indiqu la figure 8 Note Pour viter d endommager l armoire il est recommand de percer des trous de 1 16 0 16 cm de diam tre avant de fixer les supports F Fours simples voir la Fig 1 ours doubles voir la Fig 2 Seg Se eee EN og 1 1 14 Supports 2 1 l montage H Fours simples voir la Fig 1 Fours simples Fours doubles voir la Fig 2 23 1 4 59 1 cm Fours doubles 46 1 2 118 1 cm 1 1 1 Le Figure 8 3 Ins rez l unit dans le d coupage de l armoire Figure 6 Glissez l unit vers l int rieur en laissant un espace de 3 7 6 cm entre le four et le devant de l armoire Figure 9 Tout en glissant l appareil vers l int rieur tirez le c ble gain travers le trou du plancher de l armoire et vers la bo te de jonction 4 Installez maintenant la moulure inf rieure l aide des vis fournies avec l appareil Figure 10 5 Poussez l appareil l int rieur contre l armoire les supports de fixation situ s sur le c t de l appareil se fixeront derri re ceux qui viennent d tr
29. circuit breaker or fuse amperage Protection Appliance Rating Protection Watts Circuit 208V recommended Less than 4100W 20A A100W 6200W 6200W 8300W 40A 8300W and 50A Table A Observe all governing codes and local ordinances 1 3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line time delay fuse or circuit breaker is recommended DO NOT fuse neutral Consideration must be given for a combination built in oven and cooktop refer to unit serial plate of each Appliance Rating Watts Circuit 240V recommended less than 4800W 20A 4800W 7200W 7200W 9600W 40A 9600W and 50A NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI NFPA No 70 latest edition or with Canadian CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances An extension cord should not be used with this appliance Such use may result in a fire electrical shock or other personal injury 2 This appliance should be connected to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed cable The flexible armored cable extending from the appliance should be connected directly to the junction box The junction box should be located as shown in figure 1 or
30. de producto la unidad de los gabinetes ver la planilla que se incluye en el paquete de literatura y las instrucciones de instalaci n de la cocina donde est n detalladas las dimensiones Para reducir el riesgo de lesiones Approx 3 adyacentes La altura del relleno lateral del gabinete debe permitir la instalaci n de modelos de tapas de cocina aprobados personales y 7 5 cm inclinaci n del horno de pared ste debe AN asegurarse a los gabinetes mediante soportes de montaje 36 Min 91 4 cm Min 208 240 caja de empalme para hornos de pared D Instale contrachapado de 3 4 1 9 cm sobre dos correderas nivelado con la parrilla inferior La base debe poder sostener 200 libras 90 kg Corte una abertura en el fondo del contrachapado para poder encaminar el cable a la caja de empalme 4 1 2 11 5 cm Max Si se instala ninguna tapa de DIMENSIONES DE ABERTURA F ANCHURA G PROFUNDIDAD H ALTURA cocina directamente sobre la unidad del horno se permite un espacio maximo de 5 12 7 cm sobre el 30 76 2 cm 28 1 2 72 4 cm Min 28 14 71 8 cm Min piso Horno de pared 29 73 7 cm Max 24 61 cm Min 28 7 8 73 3 cm Max Figura 12 INSTALACI N T PICA DEBAJO DE LA MESADA DE HORNO SIMPLE EMPOTRADO CON TAPA DE COCINA MONTADA INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED 1 18 4
31. diense CSA Standard C22 1 Part 1 en Canada NUE Pisar apoyarse o sentarse sobre la puerta de este horno de pared puede causar serias lesiones y da os al horno de pared e Nunca use su horno de pared para calentar una habitaci n El uso prolongado de la estufa sin la ventilaci n adecuada puede ser peligroso Way La corriente el ctrica al horno debe estar apagada mientras se hacen las conexiones de l neas Si no se apaga da os serios o la muerte podr an resultar 1 Carpinter a Consulte la Figura 1 0 la figura 2 para conocer las dimen siones pertinentes al modelo de su horno y al espacio necesario en el que poner el horno La superficie donde se va a apoyar el horno debe de ser de madera contrachapada s lida u otro material similar y sobre todo la superficie tiene que estar a nivel de lado a lado y de atr s hacia adelante 2 Requerimientos El ctricos Se debe proveer el voltaje y la frecuencia apropiados a este electrodom stico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requirie su modelo vea la placa serial para encontrar la consomaci n del vatiaje y refierase al cuadro A para encontrar el amperaje del interruptor o fusible Se recomienda una protecci n al circuito Grados de Vatios Se recomienda Grados de Vatios del una protecci n del electrodom stico al circuito electrodom stico 24
32. e proper installation of the built in oven If B the oven decorative moulding does not butt against the cabinet or if noise is heard on convection models verify dimension G to assure it is according to the required dimension Hole for e 2 Suggested distance from floor is 11 29 2 cm Door Open Minimum required distance is 4 2 655 Ve 11 4 11 3 7 6 D 29 2 cm cm Max Electrical Junction Box cm Min supplied with unit Bottom edge must be finish cut Figure 2 Single Wall Oven see page 1 PRODUCT DIMENSIONS 30 76 2 cm Wall Oven 30 76 2 52916 133 5 281 4 71 8 245 s 62 5 CUTOUT DIMENSIONS AND CABINET WIDTH 30 76 2 Wall Oven 2872 72 4 29 73 7 51916 131 522 16 132 6 All dimensions are in inches cm ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the wall oven 2 Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven Observe all governing codes and ordinances Be sure to leave these instructions with the consumer THESE OVENS ARE NOT APPROVED FOR STACKABLE OR SIDE BY SIDE INSTALLATION ma Important Note to the Consumer Keep these instructions with your Owner s Guide for future reference
33. e install s au cabinet Pour retirer le four du cabinet pour l entretien ins rez les outils fournis avec l appareil dans les ouvertures situ es sur les c t s du ch ssis et visible lorsque la porte est ouverte voir la figure 11 6 L installation typique d un four encastr simple lectrique sous le comptoir est pr sent e aux figures 12 et 13 24 Espace d environ 3 7 6 cm 1 Support du four Four encastr Support de fixation install dans l armoire Armoire Outil fourni c t droit Support de fixation rel ch Four retir l armoire Ouverture o ins rer l outil Figure 11 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE Seulement certains mod les de tables de cuisson peuvent tre faut fermer les c t s de l habitacle install s au dessus de certains mod les de fours encastr s Les mod les approuv s pour tre combin s sont identifi s l aide d un num ro MGF ID et d un code de produit Consultez la feuille qui se trouve dans l enveloppe de litt rature ainsi que le feuillet d instructions d installation de la table de cuisson pour les dimensions par des panneaux de bois pour isoler l appareil des armoires de chaque c t La hauteur de ces panneaux doit faire en sorte que l installation des mod les de tables de cuisson au dessus soit possible
34. elado debe de usarse ahora para la toma a tierra del electrodom stico de acuerdo con los c digos el ctricos locales Conecte el alambre de cobre pelado de toma a tierra al alambre de toma a tierra en el panel de servicio NO conecte la toma a tierra a una tuber a de suministro de gas NO conecte el suministro de energ a el ctrica hasta que el electrodomestico tenga su toma a tierra instalada permanentemente Conecte el alambre de toma a tierra antes de enchufar por primera vez el electrodom stico Figura 4 Cable de la fuente de alimentaci n Alambre desnudo Alambre blanco Alambres rojos Alambres negros desnudo Alambre blanco conductor de uni n listado UL CSA Cable del orne a pared Figura 4 SISTEMA ELECTRICO DE 4 ALAMBRES Caja de empalmes Si esta conectado a un sistema el ctrico de 4 alambres el armaz n del electrodom stico NO TIENE QUE estar conectado al alambre neutro del sistema el ctrico de 4 alambres NOTA AL ELECTRICISTA Los conductores de cable blindados provistos con este artefacto son aprobados por UL para la conexi n al alambrado de casa de un calibre mayor El aislamiento de los conductores esta calificado para temperaturas mas altas que las del alambrado de la casa La capacidad de corriente del conductor esta gobernada por la calificaci n de la temperatura del aislamiento alrededor del alambre en vez de solamente el calibre del alambre 4 Quitar la puerta del
35. gura 3 Cable de la fuente de alimentaci n Alambre desnudo Alambres rojos Alambres negros a de empalmes Alambre blanco Alambre desnudo Conductor de uni n listado UL o CSA Cable del horno a pared Figura 3 3 PUESTA A TIERRA NEUTRAL Una conexi n incorrecta del alambrado de aluminio con los conductores de cobre puede resultar en un cortacircuito o incendio Use solamente los conectores dise ados para juntar el cobre con el aluminio y siga exactamente el procedimiento recomendado por el fabricante INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED El marco esta aterrizado a trav s del cable neutro Si es usado el electrodom stico en una casa movil 1996 NEC vehiculos recreativos o donde las leyes locales no permitar aterrizar a trav s del cable neutro vea figura 4 2 Si este horno se va a usar en una casa sobre ruedas o si los c digos locales NO permiten que el armaz n este conectado al neutro blanco de la toma a tierra separe el alambre blanco y el de toma a tierra pelado que salen del final del cable de suministro de energ a al electrodom stico Conecte el alambre blanco del cable de suministro de energ a al alambre blanco neutro en la caja de empalme Conecte el alambre negro y el alambre rojo del cable de suministro de energ a emparejando los colores con los alambres correspondientes en la caja de empalme El alambre p
36. ion 3 Electrical connection It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances Electrical ground is required on this appliance These appliances are equipped with a copper conductor flexible cable If connection is made to aluminum house wiring use only special connectors which are approved for joining copper and aluminum wires in accordance with National Electrical Code and local codes and ordinances These appliances are manufactured with a white neutral power supply wire and a frame connected green or bare copper grounding wire 1 If local codes permit connection of the frame grounding conductor to the neutral white wire Connect the green or bare copper wire and the white wire from the appliance cable to the supply cable ground wire white or bare inside the junction box Connect the remaining wires inside the junction box from the power supply cable to the matching colors of the appliance cable wires Figure 3 Cable from Power Supply Ground Wire Red Wires Ground Wire Bare or Green Wire White Wire 7 UL Listed Conduit Connector or CSA listed Cable from appliance Figure 3 3 WIRE GROUNDED JUNCTION BO
37. isted by the MFG ID number and product code see the insert sheet included in the literature package and cooktop installation instructions for dimensions Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of approved cooktop models 36 Min 91 4 cm Min 208 240 Volt junction box Use 3 4 1 9 cm plywood in stalled on two runners flush with toe plate Base must be capable of supporting 200 pounds 90 kg 41 2 11 5 cm Max Cut an opening in wood base to route armored cable to junction box If no cooktop is installed directly CUTOUT DIMENSIONS over the oven unit 5 12 7 cm F WIDTH G DEPTH H HEIGHT maximum is allowed above the 30 76 2 cm 28 1 2 72 4 cm Min 61 cm Min 28 71 8 cm Min floor Wall Oven 29 a 7 cm Max 28 7 8 73 3 cm Max Figure 12 TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS lt 18 45 7 cm Max gt GAS COOKTOP 5 Max 61 2 Min 16 5 cm 120V 60Hz Flexible Appliance Conduit Grounded Outlet Union a Pressure Regulator Cabinet sides or filler panel 2 Manual Shutoff Valve Wall Oven Cabinet Cooktop li
38. plancher est 31 78 7 cm sp cifi es dans les instructions d installation du tiroir r chaud La distance minimale requise est 41 11 4 cm Figure 1 Pour conna tre les dimensions d un four encastr double r f rez vous la figure 2 DIMENSIONS DE L APPAREIL MOD LE Ext rieur arri re Four encastr 30 76 2 cm 30 76 2 29 74 3 245 62 5 DIMENSIONS DE D COUPAGE ET DE L ARMOIRE MOD LE Four encastr 30 76 2 cm 28 72 4 29 73 7 28 71 8 287 s 73 3 30 76 2 Min Toutes les dimensions sont en pouces cm P N 318201524 0709 Rev English pages 1 8 Espa ol p ginas 9 16 Francais pages 17 24 Imprim aux Etats Unis INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE NWA SUES SS N enlevez pas les entretoises sur les parois lat rales et ou l arri re du four Ces entretoises centrent le four dans l espace fourni Le four doit tre centr pour pr venir une accumulation excessive de chaleur pouvant causer un feu ou des dommages NOTE 1 La base doit pouvoir supporter 400 lbs 22 181 4 kg 6 4 cm 2 Assurez vous que le fond du cabinet est bien niveau et que la fa ade de l armoire du est d querre Si le cabinet n est pas niveau les glissi res des grilles auront tendance glisser hors du four lors de l ouverture de la porte NOTE Allouez au moins 234 59 1 cm B d espace pour permettre l ouve
39. rno Abertura tendera a deslizar en el momento que se abre la puerta NOTA Deje por lo menos 23 59 1 8 cm de espacio libre para la profundidad de la puerta cuando esta abierta NOTA La dimensi n G esta primordial para instalar correctamente el horno de pared Si el adorno del armaz n del horno no contra el armario si escuche un vea la nota 7 ruido verifique si la dimensi n G est en conformidad con la dimensi n requerida Caja el trica Mi de empalme i proporcionado la unidad El borde inferior Distancia sugerida desde el suelo es 31 78 7 cm debe ser cortado La distancia minima requerida es 4 11 4 cm cuidadosamente NOTA Para la instalaci n combinada de este Horno Empotrable con Caj n Asador ver las dimensiones especificadas en las instrucciones de instalacion del Caj n Asador Figura 1 Para horno doble ver la figura 2 DIMENSIONES DEL APARATO MODELO A Exterior posterior Horno de pared 30 2 18 DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO MODELO min ex Gin min Mow i Horno de pared 30 24 61 28 71 8 287 s 73 3 30 76 2 Min 76 2 cm 28 2 72 4 29 73 7 P N 318201524 0709 Rev Imprimido en los Estados Unidos English pages 1 8 Espa ol p ginas 9 16 Fran ais pages 17 24 Todas las dimensiones se dan en pulgadas cm INSTRUC
40. rture de la porte du four 51174 130 2 NOTE La dimension est critique pour une bonne installation du four Si la moulure inf rieure ventilation xX du four ne s adapte pas contre l armoire ou si un bruit se fait Porte ouverte entendre sur les mod les voir la note convection v rifiez la dimension G Tad pour vous assurer qu elle est correcte Pa Sal Le bord du comptoir doit tre bien coup sans bavure Ouverturepour e c ble arm 7 6 cm Max Bo te de Jonction pas fournie avec l appareil La distance sugg r e du plancher est 111 29 2 cm La distance minimale requise est 41 11 4 cm Figure 2 Pour conn tre les dimensions d un four encastr simple r f rez vous la figure 1 DIMENSIONS DE L APPAREIL MOD LE A 1 arri re Four ou 30 76 2 cm 30 76 2 52916 133 5 281 4 71 8 245 3 62 5 DIMENSIONS DE D COUPAGE ET DE L ARMOIRE moots max Gui min 1 Four encastr 30 76 2 cm 287 72 4 29 73 7 4 61 519 16 131 523 16 132 6 30 76 2 Toutes les dimensions sont en pouces cm 20 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE Installateur 1 Lisez toutes ces instructions avant de proc der l installation de votre appareil Enlevez tout le mat riel d emballage du four avant de proc der au raccordement lectrique
41. so y hacia la caja de empalmes 4 Intale ahora el ajuste inferior utilizando los tornillos proporcionados con la unidad Figura 10 Empuje la unidad contra el gabinete y asi la abrazadera se ajustara con la otra que acaba de instalar del lado de la apertura del horno ul Para retirar el horno y llevarlo al servicio introduzca la herramienta que trae el electrodom stico en el hoyo que se encuentra del lado lateral y visible al abrir la puerta Luego de introducir la herramienta tire hacia su direcci n vea figura 11 6 Para una instalaci n t pica de un horno el ctrico incorporado debajo del mostrador ve se las figuras 12 y 13 15 3 7 6 cm 4 distancia entre la unidad y el gabinete 1 Abrazadera de montaje 1 instalada en el 2 gabinete Bracket del horno SN GABINETE Abrazadera de Horno montaje recia liberada h paces Horno retirado erramienta del gabinete incluida g introduzca la herramienta que trae el electrodom stico en el hoyo Figura 11 INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED S lo ciertos modelos de tapas de cocina se pueden instalar sobre ciertos modelos de hornos el ctricos empotrados Las tapas de cocina y los Los paneles de relleno laterales del hornos empotrados se mencionan por su n mero gabinete son necesarios para aislar de identificaci n MFG ID y c digo
42. ue el calor emana desde su interior Asar Cuando se pone el horno para asar el elemento de arriba del horno debe de ponerse rojo Convecci n Cuando se configura el horno para horneado o asado por convecci n los dos elementos se encienden y apagan en forma alterna y se enciende el ventilador El ventilador de convecci n dejar de funcionar cuando se abre la puerta del horno durante el horneado o asado por convecci n Antes de llamar al servicio Lea la secci n Lista de Control de Aver as en su Manual del Usuario Esto le podr ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricaci n de este artefacto Lea la garant a y la informaci n sobre el servicio en su Manual del Usuario para obtener el n mero de tel fono gratuito INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE L INSTALLATION ET L ENTRETIEN DOIVENT TRE EFFECTU S PAR UN INSTALLATEUR QUALIFI IMPORTANT CONSERVEZ POUR L INSPECTEUR D LECTRICIT LOCAL LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR REFERENCES ULT RIEURES POUR VOTRE S CURIT N entreposez pas ou n utilisez pas d essence ou d autres produits inflammables proximit de cet appareil ou de tout autre appareil lectrom nager La premi re tape de votre installation consiste mesurer les dimensions du d coupage actuel et les comparer au tableau de dimensions de d coupage ci dessous Vous d couvrirez
43. uide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for service phone numbers INSTRUCCIONES DE INSTALACION PARA EL HORNO ELECTRICO DE PARED LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA ADVERTENCIA PARA SU SEGURIDAD No almanece ni utilice gasolina u otros vapores y l quidos inflamables en la proximidad de este o de cualquier otro artefacto El primer paso para su instalaci n debe de ser el de medir las dimensiones de la apertura y compararlas con las que se indican en el cuadro de dimensiones del hueco de la figura 1 Posiblemente encontrar que alg n trabajo de carpinter a ser necesario ADVERTENCIA No quite los separadores de los muros laterales o y de la parte posterior del horno empotrado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentraci n excesiva de calor que podr a resultar en da os por el calor o un incendio NOTA 1 La base debe poder sostener 200 libras 90 7 kg 2 Aseg rese que la base esta a nivel y que el frente del gabinete est cuadrado Si la base del gabinete no esta nivelada las correderas del ho
44. ure fermeture manuel Armoire ou le four est install MA TABLE DE CUISSON GAZ Vue de face Vue de c t du four encastr Figure 10 INSTALLATION TYPIQUE D UNE TABLE DE CUISSON GAZ MONT E AU DESSUS D UN FOUR ENCASTR LECTRIQUE MONT SOUS LE COMPTOIR 26 INSTRUCTIONS D INSTALLATION POUR FOUR ENCASTR LECTRIQUE 7 V rification du fonctionnement Si votre appareil poss de une commande lectronique de four Toutes les fonctions qu elle contr le ont t v rifi es en usine pour leur bon fonctionnement avant que l appareil soit exp di Cependant nous vous sugg rons de v rifier nouveau le fonctionnement de la commande lectrique Reportez vous votre Manuel d utilisation et d entretien ou au feuillet minuterie pour le r glage de la commande lectronique 1 Retirer tous les items du four avant de proc der la v rification 2 Mettre l appareil sous tension 3 V rifier les op rations de la commande lectronique Cuisson V rifier que lorsque le four est en fonction cuisson l l ment de cuisson chauffe 20 secondes apr s avoir programm le four en mode cuisson si en ouvrant la porte vous sentez de la chaleur s chapper du four c est qu il fonctionne Grillage L l ment du haut rougit lorsque le four est r gl pour le mode grillage Convection Si le four est r gl pour la cuisson ou le
45. ven door is very heavy Be sure to have a firm grip before lifting the oven door off the hinges Use caution once the door is removed Do not lay door on its handle This could cause dents or scratches Lock in normal position Lock engaged for door removal Figure 5 Figure 6 Figure 7 Hinge Slot Door removed from the appliance 5 Remove the bottom trim Remove the bottom trim from the top of the unit This trim will be installed later ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS 6 Cabinet Installation WARNING Heavy Weight Hazard Use 2 or more people to move and install wall oven e Failure to follow this instructions can result in injury or damage to the unit The wall oven can tip when the door is opened The mounting brackets supplied with the wall oven must be attached to the cabinet and the appliance to prevent tipping of the wall oven and injury to persons 57 3 7 6 27 clearance between unit and front of cabinet 1 Mounting Bracket Installation Instructions 1 Find the 2 mounting brackets and screws included in the literature package 2 Install the mounting brackets in the cabinet as shown on figure 8 Note To prevent damage to cabinet it is recommended to drill 1 16 0 16 cm dia pilot holes before installing the mounting brackets F iq Single Oven see Fig 1 Double Oven see Fig 2 Figure 9