Home
Powerflow Flushing Machine MKIII
Contents
1. F RNO gt X MAKES WATER WORK Powerflow Flushing Machine MKIII Guida Utente Gebruikershandleiding Gu a de Usuarios Manual do utilizador Www fernox com Glossary Safety Information Information Product content Front Specification Back Specification Test system cleanliness Connecting system hoses Connecting dump hose Connecting overflow hose Connection Via Radiator Connection Via Pump Connection Via Powerflow Pump Head Adapter Connection Via Total Filter TF1 Flushing Adapter Connection Via Boiler Buddy Connection to mains Cap off Feed and Expansion tank UK Only Operation Initial Flush Add Fernox Cleaner F3 F5 DS40 amp Circulate Flush out Fernox Cleaner F3 F5 DS40 Individual Radiator Flush Final System Flush Add Fernox Protector F1 amp circulate Disconnect Powerflow unit and replace pump Empty Powerflow MKIII unit Balance system Descaling Fernox Powerflow Flushing Machine MKIII H Glossaire Consignes de s curit Information Contenu produit Sp cifications partie avant Sp cifications partie arrigre Propret du systeme test Raccordement des flexibles du systeme Raccordement du flexible de vidange Raccordement du flexible de trop plein Raccordement Par l interm diaire du radiateur Raccordement Par l interm diaire de la pompe Raccordement Par Powerflow Pump Head Adapter Raccordement Par Total Filter TF1 Flu
2. Abra todas las v lvulas de los radiadores Invierta el flujo cada dos minutos hasta que el TDS2 sea inferior al TDS1 10 Abrir todas as v lvulas dos radiadores Inverter a do fluxo a intervalos de dois minutos at o TDS2 ser inferior a TDS1 10 26 ES Add Fernox Protector F1 amp circulate B Ajoutez l inhibiteur Fernox Protector F1 et faites le circuler Fernox Protector F1 hinzuf gen und umlaufen lassen B Aggiungere Fernox Protector F1 e farlo circolare Voeg Fernox Protector F1 toe laat circuleren Ponga Fernox Protector F1 y h galo circular EB Adicionar Fernox Protector F1 e fazer circular Fernox Powerflow Flushing 27 Sequence order E Ordre de la s quence Fernox Protector F1 OR Protector Test Kit H Assurez vous que le niveau d inhibiteur Fernox Protector est ad quat Check Fernox Protector level is adequate Fernox Powerflow Flushing Machine MKIII Orden de secuencia Sequenzfolge E Ordine di sequenza Volgorde Ordem sequencial TF1 Compact Filter Pr fen ob der Pegel des Fernox Protector ausreichend ist Ga na of er voldoende Fernox Compruebe que el nivel Protector is de Fernox Protector sea correcto Verificar se o n vel de Fernox Protector adequado Controllare che Fernox Protector sia sufficiente 28 SIS Disconnect Powerflow unit and replace pump D connectez l unit
3. El peso maximo de la unidad en uso es de 54 120105 La unidad Fernox Powerflow ha sido disenada para funcionar con seguridad a la temperatura maxima del sistema de 85 C 185 F sin que el operario entre en contacto directo con el agua caliente La unidad Fernox Powerflow debe siempre conectarse a la toma de corriente mediante un Dispositivo de Corriente Residual RCD A unidade Fernox Powerflow pesa 20 kg 44lbs quando vazia O peso maximo da unidade em utiliza o de 54 kg 120105 A unidade Fernox Powerflow foi concebida para operar com seguranca a uma temperatura m xima do sistema de 85 C 185 F sem O operador entrar em contacto directo com agua quente Proteger o piso contra derramamentos acidentais de agua e de produtos quimicos A unidade Fernox Powerflow deve ser sempre ligada a tomada de alimentac o el ctrica atrav s de um dispositivo de protec o diferencial residual RCD SIS Product content Contenu produit Produktinhalt E E Contenuto prodotto ZZ Productinhoud Contenido del producto Ell Conte do do produto U ces ra Woking Surrey GUE lect 44 STO 0062 E Fernox Powerflow Flushing Machine MKIII 6 Fernox Powerflow Flushing Machine MKIII Za Back specification B E Sp cifications partie arriere Bestandteile hinten E E Specifiche posteriori Achteraan Specificaties ZZ Especi
4. Powerflow et replacez la pompe Powerflow MKIII trennen und Pumpe wieder anbringen E E Scollegare la macchina Powerflow MKIII e sostituire la pompa Koppel de Powerflow MKIII eenheid los en de pomp terug Desconecte la unidad Powerflow MKIII y vuelva a poner la bomba Desligar a unidade Powerflow voltar a colocar a bomba Fernox Powerflow Flushing 29 Empty Powerflow unit videz l unit Powerflow E Powerflow MKIII leeren E vuotare la macchina Powerflow Maak de Powerflow MKIIl eenheid leeg Vac e la unidad Powerflow Esvaziar a unidade Powerflow 1 ar Sequence order E Ordre de la s quence Sequenzfolge E Ordine di sequenza Volgorde Orden de secuencia Ordem sequencial Fernox Powerflow Flushing Machine MKIII 30 ES Balance system quilibrez l installation Anlage ausbalancieren E Equilibrare l impianto Breng de installatie in evenwicht Equilibre el sistema EB Equilibrar o sistema oo 1212 mei 422 as Fernox Powerflow Flushing Machine MKIII 31 Descaling B E D tartrage Entkalken E E Disincrostazione Aanslag verwijderen Desincrustaci n Descalcificar As H e changeur thermique Sekundar Scambiatore di calore Secundaire warmwater Intercambiador de e Secondary hot water Permutador de calor heat exchanger in combina
5. o de gua produzida pela bomba Powerflow limitada a 2 3 bars 35 psi para evitar riscos de danificar os componentes do sistema que possam ventura levar a um vazamento Os operadores devem estar sempre em controlo da unidade Powerflow durante a opera o A m quina n o deve ser deixada sem a supervis o Lo SIS Information EE Information Informationen E E Informazioni ZZ Informatie Informaci n El Informa o Sy a The Powerflow MKIII Flushing Machine weighs 20Kg 44lbs empty The maximum weight of the unit in use is 54Kg 120105 The Powerflow MKIII Flushing Machine is designed to operate safely at full system temperature of 85 C 185 F without the operator coming into direct contact with hot water Protect floor surfaces from water and chemical accidental spills The Powerflow MKIII Flushing Machine should always be connected to the electrical supply via a Residual Current Device RCD Fernox Powerflow Flushing Machine MKIII L unit Fernox Powerflow pese 20 kg 44lbs lorsqu elle est vide Le poids maximal de l unit en cours d utilisation est 54 kg 120105 L unit Powerflow a t conque pour une utilisation en toute s curit a temp rature optimale 85 C 185 F sans contact direct de l op rateur avec l eau chaude L unit Fernox Powerflow doit toujours tre connect e l alimentation secteur par le biais d un disposi
6. Verbind met behulp van adapters de ingang en uitgang van de boiler warmtewisselaar met de toevoer en retourslangen op de thermische opslagcilinders van de Powerflow MKIII Thermische opslag Verbind de ingang uitgang van de spiraal warmtewisselaar met de toevoer en retourslangen van de Powerflow MKIII eenheid Reinig en laat circuleren met Fernox DS 3 Limescale Remover neutraliseer en spoel calor del agua caliente secundario en calderas de combinaci n Conecte con adaptadores la entrada de agua y la salida de agua caliente desde la caldera de combinaci n hasta los conductos de retorno y flujo de la unidad Powerflow Intercambiador de calor primario Conecte con adaptadores la entrada y la salida de la caldera intercambiador de calor hasta los tubos de flujo y retorno de los cilindros de almacenamiento t rmico de la unidad Powerflow MKIII Almacenamiento t rmico Conecte la entrada salida del serpent n intercambiador de calor a los tubos de flujo y retorno de la unidad Powerflow MKIII L mpielo y h galo circular con Fernox DS 3 Limescale Remover neutralicelo y p rguelo secund rio para gua quente em caldeiras mistas Ligar com os adaptadores a entrada de gua e a sa da de gua quente da caldeira mista s mangueiras de fluxo e de retorno da unidade Powerflow MKIII Permutador de calor prim rio Ligar com os adaptadores a entrada e a sa da da caldeira pe
7. coming into direct contact with hot water However when disconnecting the machine hot water may be present in the hoses and reasonable care must be taken by allowing the system to cool before disconnecting the Powerflow unit Bystanders should be kept at a safe distance Risk to operator from manual handling Back injuries As with all large or heavy goods care should be taken to prevent injury from manual handling The Fernox Powerflow weighs 20kg 44 lbs empty and is fitted with a carry handle and casters to facilitate transport The total weight of the hoses is an additional 12kg 26 105 The Powerflow MKIII must be emptied before moving or transporting to or from site as the weight when filled with water will be over 50kg 110 Ibs Operators should satisfy themselves that they have the capability to lift and transport the unit safely Chemical safety of the operator Health risks associated with chemical contact Safety of children amp bystanders Always follow the safety advice relating to the Fernox chemicals being used At all times keep children and bystanders away from the Powerflow MKIII hoses and all chemicals In general operators should use appropriate personal protective equipment for the chemical being handled refer to product MSDS and wash their hands after using any chemicals If adverse health effects are suspected seek immediate medical advice Risks to the environment from cleaning effluent All effluen
8. consultare immediatamente un medico Rischi per l ambiente derivanti dai detergenti di scarico Tutti gli scarichi provenienti dall impianto di riscaldamento centralizzato devono essere smaltiti in modo sicuro conformemente alla normativa locale e alle istruzioni specifiche sui prodotti chimici utilizzati Gli scarichi dell impianto non devono mai entrare a contatto o inquinare l acqua di superficie o freatica Lunita Powerflow di Fernox dotata di una valvola di controllo doppia sul carico di acqua di rete per evitare la contaminazione di ritorno derivante dagli scarichi dell impianto sulla conduttura dell acqua Rischio di danni dell acqua a carico della struttura e degli allestimenti del sito Per evitare i danni dell acqua su pavimenti e allestimenti del sito si raccomanda sempre di utilizzare Powerflow su un telone impermeabile o in una vasca per proteggere il sito da eventuali rovesciamenti di acqua o prodotti chimici Inoltre si raccomanda vivamente di effettuare ispezioni regolari ai tubi e alle guarnizioni dei tubi e di sostituire le parti danneggiate prima dell uso macchinario deve essere sempre utilizzato su una superficie piana 51 invitano gli operatori ad ispezionare regolarmente tutte le parti dell impianto eventualmente esposte durante la pulizia per evitare i danni causati dall acqua e da possibili fuoriuscite La pressione dell acqua prodotta dalla pompa Powerflow limitata a 2 3 bar 35 psi per evitare i rischi di d
9. d charge jusqu a 2 Minuten umkehren Scaricare fino a quando tot het water schoon is Purgar hasta que el agua de dois minutos Descarregar ce que soit claire Laufen lassen bis das esce pulita salga limpia at a agua sair incolor Wasser klar ist Fernox Powerflow Flushing Machine MKIII 24 SIS Final System Flush ELE Rincage final de l installation M Endg ltiges Durchsp len der Anlage l Lavaggio finale dell impianto Laatste installatiespoeling Purga final del sistema E Lavagem final do sistema Fernox Powerflow Flushing Machine MKIII 25 Lo Sequence order E Ordre de la s quence Sequenzfolge E Ordine di sequenza Volgorde H Open all radiator valves Ouvrez tous les robinets Alle Heizk rperventile ffnen Aprire le valvole di tutti i Reverse flow every two de radiateurs Inversez le Die Durchflussrichtung alle radiatori Invertire il flusso minutes until TDS2 is less flux toutes les deux minutes zwei Minuten umkehren ogni due minuti fino a than TDS1 10 jusqu a ce que la quantit bis TDS2 die Summe der quando TDS2 inferiore totale de solide dissous TDS2 gel sten Salze TDS1 10 al TDS1 10 soit inf rieure TDS1 10 oder niedriger ist Fernox Powerflow Flushing Machine MKIII Orden de secuencia Open alle radiatorkranen Keer de stroming om de twee minuten om tot de TDS2 kleiner is dan TDS1 10 Ordem sequencial A TDS2 lt TDS1 10
10. evitar da os producidos por el agua derivados de fugas reveladas por la limpieza La presi n de agua producida por la bomba Powerflow se limita a 2 3 bares 35psi para evitar el riesgo de da os en los componentes del sistema que podr an resultar en fugas Los operarios deben permanecer en control de la unidad Powerflow en todo momento durante su operaci n y la m quina no deber dejarse desatendida Risco de electrocuss o e gravidade de morte ao operador Para ser usado somente dentro de casa A bomba Fernox Powerflow deve estar sempre conectada ao suprimento el ctrico atrav s do Dispositivo de Corrente Residual Residual Current Device RCD Recomenda se que uma inspecc o do cabo el ctrico e da ficha seja efectuada regularmente As pecas danificadas devem ser substitu das antes da utiliza o O motor Powerflow est protegido contra sobrecargas e gripagens atrav s do interruptor liga desliga on off e do disjuntor A m quina deve estar fisicamente desconectada do suprimento el ctrico principal antes de efectuar a desmontagem ou a manuten o Toda a manuten o deve ser efectuada por pessoas competentes utilizando somente pe as novas e aprovadas Risco de escaldadela ao operador e s pessoas que se encontram perto O uso de temperaturas altas em limpezas tem mostrado oferecer desempenho significativo e a bomba Fernox Powerflow foi projectado para operar seguramente temperatura do sistema de at 85 C 185 F sem
11. Adapter Aansluiting Via Boiler Buddy Aansluiting op net Watertank afsluiten enkel VK In gebruik nemen Eerste spoeling Voeg Fernox Cleaner F3 F5 DS40 toe en laat circuleren Spoel Fernox Cleaner F3 F5 DS40 uit Individuele radiator spoelen Laatste installatiespoeling Voeg Fernox Protector F1 toe en laat circuleren Koppel de Powerflow MKIII eenheid los en zet de pomp terug Maak de Powerflow MKlll eenheid leeg Breng de installatie in evenwicht Aanslag verwijderen Glosario Informaci n de seguridad Informaci n Contenido del producto Especificaciones delanteras Especificaciones traseras Probar la limpieza del sistema Conexi n de los tubos del sistema Conexi n del tubo de vaciado Conexi n del tubo de desbordamiento Conexi n V a el radiador Conexi n V a la bomba Conexi n V a Powerflow Pump Head Adapter Conexi n V a Total Filter TF1 Flushing Adapter Conexi n V a Boiler Buddy Conexiones a la red Alimentaci n por adaptador y tanque de expansi n Reino Unido solamente Funcionamiento Purga inicial Ponga Fernox Cleaner F3 F5 DS40 y h galo circular Purgue Fernox Cleaner F3 F5 DS40 Purga individual de los radiadores Purga final del sistema Ponga Fernox Protector F1 y hagalo circular Desconecte la unidad Powerflow y vuelva a poner la bomba Vacie la unidad Powerflow MKIII Equilibre el sistema Desincrustaci n Gloss rio Informac o de seguranca Infor
12. Als u het apparaat echter ontkoppelt is er mogelijk heet water in de slangen aanwezig Er moet dan ook worden gezorgd dat het systeem afdoende is afgekoeld voordat de Powerflow eenheid wordt ontkoppeld Omstanders moeten een veilige afstand houden Risico voor de operator bij handmatig gebruik Rugletsels Zoals met alle grote of zware goederen dient de operator om letsels te voorkomen voorzichtig om te gaan met de pomp tijdens het gebruik De Fernox Powerfloweenheid weegt 20 kg 44 Ibs in lege toestand en is voorzien van een draaggreep en wieltjes om de verplaatsing te vereenvoudigen Het totaal gewicht van de slangen is een extra 12 kg 26 lbs The Powerfloweenheid moet geledigd worden alvorens hem te verplaatsen of te transporteren van naar een andere plaats omdat deze in gevulde toestand meer dan 50 kg 110 Ibs weegt Operators moeten zich er van vergewissen dat ze bekwaam zijn om de pomp op een veilige manier op te tillen en te verplaatsen Chemische veiligheid van de operator Gezondheidsrisico s met betrekking tot chemisch contact Veiligheid van kinderen en omstanders Volg altijd de veiligheidsaanbevelingen met betrekking tot de chemische stoffen van Fernox die worden gebruikt Houd kinderen en omstanders te allen tijde uit de buurt van de Powerflow machine slangen en alle chemische stoffen In het algemeen moeten operators de relevante persoonlijke beschermingsmiddelen voor de gehanteerde chemische stof gebruiken zie MSDS voor h
13. I para sustituir el agua que hay en el sistema por agua de la red hasta que salga limpia Mantenga el nivel del agua mediante el llenado de la red y el vertido abierto Usar a unidade Powerflow MKIII para substituir a gua existente no sistema por gua da rede at a gua descarregada sair limpa Manter o n vel da gua com a v lvula de gua da rede e a v lvula de descarga abertas Eis Add Fernox Cleaner F3 F5 DS40 amp Circulate EE Ajoutez le produit nettoyant Fernox Cleaner F3 F5 DS40 et faites le circuler Fernox Cleaner F3 F5 DS40 hinzuf gen und umlaufen lassen l B Aggiungere Cleaner F3 F5 DS40 e farlo circolare Voeg Fernox Cleaner F3 F5 DS40 toe en laat circuleren Ponga Fernox Cleaner F3 F5 DS40 y h galo circular EB Adicionar Fernox Cleaner F3 F5 DS40 e fazer circular Fernox Powerflow Flushing Machine MKIII 19 Sequence order E Ordre de la s quence Sequenzfolge E Ordine di sequenza Volgorde Orden de secuencia Ordem sequencial Fernox Powerflushing OR Fernox Cleaner F3 Cleaner E5 H i EN Reverse flow every 15 Inversez le flux toutes les Die Durchflussrichtung alle Invertire il flusso ogni 15 Keer de stroming om de Invierta el flujo cada 15 Inverter a direcgao do fluxo minutes for 1 2 hours 15 minutes pendant 1 2 15 Minuten 1 2 Stunden lang minuti per 1 2 ore 15 minuten gedurende 1 2 minutos durante 1 2 horas a intervalos de 15 minutos he
14. an door lekken die tijdens de reiniging worden blootgesteld De waterdruk die door de Powerflow pomp wordt geproduceerd wordt beperkt tot 2 3 bar 35 psi ter preventie van risico op schade aan installatieonderdelen die anders tot lekken kunnen leiden Operators moeten de Powerflow eenheid tijdens de werking te allen tijde onder controle houden en het apparaat mag niet onbeheerd worden achtergelaten Fernox Powerflow Flushing Machine MKIII iRiesgo de electrocuci n y peligro de muerte para el operario Para uso en el interior exclusivamente La bomba Fernox Powerflow deber conectarse siempre al suministro el ctrico a trav s de un dispositivo de corriente residual RCD Se recomienda encarecidamente la inspecci n frecuente del cable de corriente y del enchufe Las piezas da adas deber n reemplazarse antes del uso El motor Powerflow se protege contra la sobrecarga y el agarrotamiento del eje mediante el interruptor de encender apagar y el disyuntor La m quina deber estar f sicamente desconectada del suministro el ctrico de la red antes de desmontarla o revisarla El mantenimiento deber realizarlo siempre una persona competente que solo utilice piezas nuevas aprobadas Riesgo de escaldadura para el operario y los transe ntes Debido a que la limpieza a alta temperatura ha demostrado ser mucho m s eficaz la bomba Fernox Powerflow se ha dise ado para funcionar con seguridad a una temperatura de sistema de hasta 85 C 185 F s
15. anni alle componenti dell impianto che potrebbero altrimenti causare fuoriuscite Gli operatori devono mantenere il controllo dell unit Powerflow in qualsiasi momento durante il suo funzionamento e non lasciare mai il macchinario incustodito AS Safety Information E E Consignes de s curit BH Informationssafety E E Informazioni di sicurezza Veiligheids informatie Informaci n de seguridad EM Informa o de seguran a Elektrocutierisico dodelijk gevaar voor de operator Alleen voor binnengebruik De Fernox Powerflow pomp moet altijd met een aardlekschakelaar op het elektriciteitsnet worden aangesloten Het wordt ten zeerste aanbevolen om het netsnoer en de stekker regelmatig te inspecteren Beschadigde onderdelen moeten voor gebruik worden vervangen De Powerflow motor wordt door de aan uit schakelaar en zekering tegen overbelasting en vastlopen van de aandrijfas beschermd Het apparaat moet voorafgaande aan demontage of reparaties fysiek van het elektriciteitsnet worden ontkoppeld Alle onderhoud moet worden uitgevoerd door een deskundige en er mogen alleen nieuwe goedgekeurde onderdelen worden gebruikt Brandgevaar voor operator en omstanders Aangezien reiniging op hoge temperatuur aanmerkelijk betere prestaties blijkt te geven is de Fernox Powerflow pomp zodanig ontworpen dat hij veilig werkt bij een systeemtemperatuur tot 85 C 185 F zonder dat de operator in direct contact met heet water komt
16. enw Powerflow MKIII leeren Anlage ausbalancieren Entkalken H Glossario Informazioni di sicurezza Informazioni Contenuto prodotto opecifiche anteriori opecifiche posteriori Pulizia Impianto Test Tubo di scarico del troppo pieno Collegamento Flessibile Scarico Collegamento Flessibile Trabocco Collegamento Tramite radiatore Collegamento Tramite pompa Collegamento Tramite Powerflow Pump Head Adapter Collegamento Tramite Total Filter TF1 Fushing Adapter Collegamento Tramite Boiler Buddy Collegamento alla rete Tappare Alimentazione e Serbatoio d Espansione Funzionamento Lavaggio iniziale Aggiungere Fernox Cleaner F3 F5 0540 e farlo circolare Lavare con il Fernox Cleaner F3 F5 DS40 Lavaggio singolo del radiatore Lavaggio finale dell impianto Aggiungere Fernox Protector F1 e farlo circolare Scollegare la macchina Powerflow MKIII e sostituire la pompa Vuotare la macchina Powerflow MKIII Equilibrare l impianto Disincrostazione SIS ES Index Index Bill Inhaltsverzeichnis E indice e Index EZ ndice EH ndice Woordenlijst Veiligheids informatie Informatie Productinhoud Vooraan Specificaties Achteraan Specificaties Zuiverheid van installatie testen Installatieslangen aansluiten Leegloopslang aansluiten Overloopslang aansluiten Aansluiting radiator Aansluiting Via pomp Aansluiting Via Powerflow Pump Head Adapter Aansluiting Via Total Filter TF1 Flushing
17. esundheitliche Beeintrachtigung ziehen Sie sofort einen Arzt hinzu Umweltrisiken durch Reinigungsabwasser Samtliche Abw sser aus Zentralheizungsanlagen m ssen gem f den rtlichen Vorschriften und den besonderen Anweisungen zu den verwendeten Chemikalien sicher entsorgt werden Anlagenabwasser darf grundsatzlich nicht in das Oberfl chen und Grundwasser gelangen oder es verschmutzen Die Fernox Powerflow besitzt am Wassereinlauf ein Doppelr ckschlagventil das die Kontamination des Wasserleitungssystems durch Anlagenabwasser verhindert Risiko f r Wassersch den an Geb ude und Innenausstattung Um Wassersch den an B den und Einrichtung vor Ort zu verhindern wird empfohlen die Powerflow grunds tzlich auf einer wasserdichten Bodenfolie oder in einem Tankwall zum Schutz der Einrichtung vor Wasser oder Chemikalienspritzern zu verwenden Eindringlich empfohlen wird au erdem die regelm ige Kontrolle der Schl uche und Schlauchanschl sse Besch digte Teile m ssen vor dem Gebrauch ausgewechselt werden Die Maschine muss grunds tzlich auf einer ebenen Fl che stehen Betreibern wird geraten alle Teile des Systems w hrend der Reinigung regelm ig zu kontrollieren um Wassersch den zu vermeiden die durch bei der Reinigung freigelegte Lecks verursacht werden k nnen Der von der Powerflow Pumpe erzeugte Wasserdruck ist auf 2 3 bar 35 psi begrenzt um das Risiko von Sch den an Systemkomponenten zu vermeiden die ansonsten z
18. et product en hun handen direct na het gebruik van chemische stoffen wassen Als er negatieve gezondheidseffecten worden vermoed moet er onmiddellijk medisch advies worden ingewonnen Het afvalwater van reinigingsmiddelen levert risico s voor het milieu op Al het afvalwater van centrale verwarmingsinstallaties moet op een veilige manier worden afgevoerd conform lokale voorschriften en de specifieke instructies met betrekking tot de gebruikte chemische stoffen Het afvalwater van de installatie mag nooit in oppervlaktewater en grondwater terecht komen of dit verontreinigen De Fernox Powerflow is uitgerust met een dubbele controleklep op de invoer van het leidingwater zodat verontreiniging door terugstromend afvalwater uit de installatie wordt voorkomen Waterschaderisico aan structuur en meubilair van het gebouw Ter preventie van waterschade aan vloeren en het meubilair in het gebouw wordt aanbevolen de Powerflow altijd te gebruiken op een waterdicht grondzeil of in een reservoir met rand zodat het gebouw wordt beschermd tegen water of het morsen van chemische stoffen Het wordt ook ten zeerste aanbevolen de slangen en slangaansluitingen regelmatig te inspecteren Beschadigde onderdelen moeten voor gebruik worden vervangen Het apparaat moet altijd op een egaal oppervlak worden gebruikt Operators wordt aanbevolen alle onderdelen van de installatie tijdens het reinigen regelmatig te inspecteren ter preventie van waterschade die kan ontsta
19. ficaciones traseras EM Especifica es para a parte de tr s da m quina Fernox Powerflow Flushing Machine MKIII i F Dump Control Valve G Dump with Hose Connected H On Off switch I Mains Water Valve 4 Flow direction Tank Empty Valve K Overflow with Hose Connected F Vanne de regulation de la vidange Vidange avec tuyau connect Interrupteur marche arr t Robinet d eau de ville J Vanne de flux retour vidange du r servoir K Trop plein avec tuyau connect F Entleerungsregulierventil G Entleerungs ffnung mit angeschlossenem Schlauch H Ein Aus Schalter Ventil f r Wasserhauptleitung J Durchfluss R cklauf Tankentleerungsventil K Uberlauf mit angeschlossenem Schlauch F Valvola controllo scarico G Scarico col flessibile collegato Interruttore ON Off Valvola dell acqua di rete J Valvola flusso ritorno serbatoio vuoto Tubo collegato allo scarico del troppo pieno Leegmaak regelklep Leegmaken met aangesloten slang H Aan uit schakelaar Leidingwaterkraan 4 Stromings retour tankleegmaakklep Overloop met aangesloten slang F V lvula de control de descarga G Descarga con tubo conectado Interruptor de encendido apagado Valvula de la entrada principal de agua Valvula de vaciado de flujo escape tanque Desbordamiento con tubo conectado ACTI F V lvu
20. iciteit Balans Bekijken Peil in stand houden Nat werken Installatietemperatuur Precaucion Precaucion Electricidad Equilibrar Vigilar Mantener el nivel Funcionamiento humedo Temperatura del sistema Atengao Atengao Electricidade Equilibrar Vigiar Manter 0 nivel ambientes Temperatura sistema Fernox Powerflow Flushing Machine MKIII EI 5 Safety Information EE Consignes de s curit Informationssafety E E Informazioni di sicurezza Veiligheids informatie ZZ Informaci n de seguridad EB Informa o de seguran a Risk of electrocution and danger of death to operator For indoor use only The Fernox Powerflow Flushing machine MKIII should always be connected to the electrical supply via Residual Current Device RCD Regular inspection of the power lead and plug is strongly recommended Damaged parts should be replaced before use The Powerflow MKIII motor is protected against overload and shaft seizure by the on off switch and circuit breaker The machine must be physically disconnected from the mains electricity supply before disassembly or servicing All maintenance should be carried out by a competent person using only new approved parts Risk of scalding to operator and bystanders As high temperature cleaning has been shown to give significantly enhanced cleaning performance the Fernox Powerflow pump is designed to operate safely at a system temperature up to 85 C 185 F without the operator
21. in que el operario entre en contacto directo con agua caliente No obstante al desconectar la m quina podr a encontrarse agua caliente en las mangueras por lo que se deber actuar con una precauci n razonable dejando que el sistema se enfrie antes de desconectar la unidad Powerflow Los transe ntes deber n mantenerse a una distancia segura Riesgo para el operario en el manejo manual Lesiones de espalda Al igual que con otros art culos voluminosos o pesados se deber tener cuidado para prevenir las lesiones derivadas del manejo manual La unidad Fernox Powerflow pesa 20 kg vac a y est provista de un asa y de roldanas para facilitar el transporte El peso total de las mangueras a ade otros 12kg La Powerflow debe vaciarse antes de moverla o transportarla a o desde un emplazamiento ya que el peso cuando est llena de agua supera los 50 kg Los operarios deber n estar seguros de poder levantar y transportar la unidad con seguridad Seguridad qu mica del operario Riesgos para la salud asociados con el contacto qu mico iSeguridad de ni os y transe ntes Obedezca siempre los consejos de seguridad relacionados con los productos qu micos Fernox que se utilicen Mantenga alejados de la m quina Powerflow las mangueras y todos los productos qu micos a los ni os y los transe ntes en todo momento En general los operarios deber n utilizar equipo apropiado de protecci n personal para los productos qu micos utilizados consu
22. it Adaptern am Rucklauf und Durchflussschlauch des Powerflow MKIII anschlieBen Primarwarmeaustauscher Den Zulauf und Auslauf vom Boiler Warmeaustauscher mit Adaptern am Durchfluss und Rucklaufschlauch an den Zylindern des Warmespeichers des Powerflow anschlieBen Warmespeicher Den Zulauf Auslauf von Spulen Warmeaustauscher zum Durchfluss und Rucklaufschlauch des Powerflow anschlieBen Mit Fernox DS 3 Limescale Remover reinigen und umlaufen lassen neutralisieren und durchspulen acqua calda secondari in caldaie a combinazione Collegare con gli adattatori l ingresso acqua e acqua calda dalla caldaia a combinazione all bussole di ritorno e di flusso della macchina Powerflow MKIll Scambiatore di calore primario Collegare con gli adattatori ingresso e l uscita dalla caldaia scambiatore di calore ai flessibili di flusso e di ritorno dei cilindri di conservazione termica del Powerflow MKIll Conservazione termica Collegare l ingresso uscita dal serpentino scambiatore di calore ai flessibili del flusso e di ritorno della macchina Powerflow Pulire e far circolare utilizzando Fernox DS 3 Limescale Remover neutralizzare e lavare warmtewisselaar in combinatieboilers Verbind met behulp van adapters de wateringang en de warmwateruitgang van de combinatieboiler met de retour en toevoerslangen van de Powerflow MKIIl eenheid Primaire warmtewisselaar
23. la de controlo de descarga G Descarga com tubo ligado nterruptor de ligar desligar V lvula de gua da rede V lvula de fluxo retorno drenagem do tanque K Extravasamento com tubo ligado TDS1 Fernox Powerflow Flushing Machine MKIII TDS2 TDS2 lt TDS1 10 Connecting system hoses Raccordement des flexibles du syst me Anschluss der Anlagenschl uche E E Collegamento del tubo allo scarico del troppo pieno zzz Installatieslangen aansluiten 2 Conexi n de los tubos del sistema lt E E Ensure FLOW LEFT and V rifier que les robinets FLOW RIGHT are closed FLOW LEFT et FLOW RIGHT sont ferm s Fernox Powerflow Flushing Machine MKIII EM Ligar os tubos flex veis ao sistema K Sicherstellen dass FLOW LEFT und FLOW RIGHT geschlossen sind FLOW RIGHT Sa ech Assicurarsi che FLOW LEFT e FLOW RIGHT siano chiusi ch Zorg ervoor dat FLOW LEFT en FLOW RIGHT gesloten zijn Asegurese de que FLOW LEFT y FLOW RIGHT est n cerrados Assegurar que FLOW LEFT e FLOW RIGHT estao fechados Powerflow Flushing Machine MKIII SIS Connection Raccordement Anschluss E E Collegamento ZZ Aansluiting ZZ Conexi n Liga o Radiator Par l interm diaire du radiateur Uber Heizk
24. lourds ou de grande taille il est important de faire attention afin d viter des blessures li es la manutention Lunit Fernox Powerflow p se 20 kg vide et elle est quip e d une poign e et de roulettes pour faciliter le transport Les tuyaux quant eux repr sentent un poids suppl mentaire de 12 kilos Veiller vider la pompe Powerflow avant de la d placer ou de la transporter sur le site ou en dehors de celui ci car une fois le remplissage d eau effectuer le poids peut tre sup rieur 50 kg Les op rateurs devront s assurer qu ils sont capables de soulever et de transporter l unit en toute s curit S curit de l op rateur par rapport aux produits chimiques Risques pour la sant associ s aux contacts avec les produits chimiques S curit des enfants et des personnes tierces Toujours respecter les consignes de s curit se rapportant aux produits chimiques Fernox utilis s Veiller loigner tout moment les enfants et les personnes tierces de l appareil Powerflow ainsi que des tuyaux et des produits chimiques En r gle g n rale les op rateurs devront utiliser les quipements de protection personnelle appropri s aux produits chimiques faisant l objet d une manipulation pri re de se r f rer aux fiches de donn es de s curit des produits et devront se laver les mains apr s avoir utilis tout produit chimique En cas de crainte d une atteinte l int grit physique consulter imm diate
25. lte la hoja de datos de seguridad del producto y lavarse las manos despu s de utilizar cualquier producto Si se sospechan efectos adversos para la salud solicite asistencia m dica inmediatamente Riesgos para el medio ambiente de los efluentes de limpieza Todos los efluentes de sistemas de calefacci n central deber n eliminarse con seguridad en conformidad con las normativas locales y las instrucciones espec ficas aplicables a los productos qu micos en uso Nunca se deber permitir que el efluente del sistema penetre o contamine el agua superficial o subterr nea La Fernox Powerflow est provista de una v lvula de retenci n doble en la toma de agua de la red para prevenir la contaminaci n por reflujo del suministro de agua con el efluente del sistema Riesgo de da os producidos por el agua en la estructura y mobiliario de la propiedad Para evitar da os producidos por el agua en los suelos y mobiliario del emplazamiento se recomienda utilizar siempre la Powerflow sobre una cubierta de suelo impermeable o una bandeja de retenci n esto proteger la propiedad contra los derrames de agua o qu micos Antes del uso se recomienda encarecidamente la inspecci n frecuente de las mangueras y sus ajustes as como el recambio de las piezas da adas La m quina deber utilizarse siempre sobre una superficie nivelada 86 aconseja a los operarios que inspeccionen con frecuencia todas las piezas del sistema durante la limpieza para
26. mac o Conte do do produto Especificagoes para a frente da m quina Especificac es para a parte de tr s da m quina Testar a limpeza do sistema Ligar os tubos flex veis ao sistema Ligar o tubo de descarga Ligar o tubo ladr o Ligac o Atrav s do radiador Ligac o Atrav s da bomba Ligac o Atrav s Powerflow Pump Head Adapter Ligac o Atrav s Total Filter TF1 Flushing Adapter Ligac o Atrav s Boiler Buddy Ligac o rede Retirar a tampa do tanque de alimentac o e de expans o apenas RU Operac o Lavagem inicial Adicionar Fernox Cleaner F3 F5 DS40 e fazer circular Drenar o Fernox Cleaner F3 F5 DS40 Lavagem individual de radiadores Lavagem final do sistema Adicionar Fernox Protector F1 e fazer circular Desligar a unidade Powerflow MKIII e voltar a colocar a bomba Esvaziar a unidade Powerflow MKIII Equilibrar o sistema Descalcificar ki E 10 11 12 13 13 13 14 14 15 16 17 18 19 N 23 27 29 30 31 32 Glossary Glossaire Wii Glossar E E Glossario ZZ Woordenlijst ZZ Glosario Gloss rio y E Sequence order 3 hours duration 15 minutes duration Repeat Flow direction Correct dumping to foul Incorrect dumping to soak Incorrect dumping to garden drain away y Ordre de la s quence Dur e 3 heures Dur e 15 minutes R p ter Sens de l coulement Evacuation correcte dans la Evacuation incorrecte dans Evacuation inc
27. ment un m decin Risques pour l environnement li s au nettoyage des eaux r siduaires II est important de veiller disposer de toutes les eaux r siduaires provenant des syst mes de chauffage central en conformit avec les r glementations locales et les instructions sp cifiques se rapportant aux produits chimiques utilis s Les eaux du syst me ne doivent jamais polluer ou entrer en contact avec les eaux de surface ou les eaux souterraines La pompe Fernox Powerflow est quip e d un clapet de non retour double plac au niveau de l arriv e de l eau courante afin d viter toute contamination en retour de l eau courante par les eaux r siduelles de syst me Risque de d g ts des eaux concernant la structure et les am nagements du b timent Afin d viter que les sols et les am nagements du site ne soient endommag s par un d g t des eaux il est recommand de toujours utiliser la pompe Powerflow au dessus d un rev tement de sol imperm able ou l int rieur d une cuve de protection afin de prot ger les biens en cas de renversement d eau ou de produits chimiques En outre nous recommandons d inspecter r guli rement les tuyaux ainsi que les accessoires de tuyaux et de toujours remplacer les pi ces endommag es avant de proc der l utilisation La machine devra toujours tre utilis e sur une surface plane Les op rateurs sont avis s d inspecter r guli rement toutes les parties du syst me pendant les op ratio
28. n int rieur Veiller toujours relier la pompe Fernox Powerflow l alimentation lectrique par le biais du dispositif diff rentiel r siduel DDR Nous recommandons vivement de v rifier r guli rement le fil lectrique et la prise Les pi ces endommag es devront tre chang es avant de proc der l utilisation Le moteur Powerflow est prot g de mani re faire face au risque de surcharge et de blocage de l axe par l interrupteur marche arr t et par le disjoncteur Veiller toujours d brancher la machine du secteur avant de la d monter ou de la r parer Toutes les r parations devront tre r alis es par une personne comp tente utilisant uniquement des pi ces neuves et homologu es Risque de br lure pour l op rateur et les personnes tierces Comme il a t d montr que le nettoyage haute temp rature permet une performance de nettoyage grandement am lior e la pompe Fernox Powerflow a t con ue pour fonctionner en toute s curit jusqu 85 C 185 F sans que l op rateur ait besoin d avoir un contact direct avec l eau chaude Cependant au moment du d branchement de la machine il sera possible qu il reste de l eau chaude dans les tuyaux et il faudra donc veiller laisser le syst me se refroidir avant de d brancher l unit Powerflow Les personnes tierces devront se tenir une distance raisonnable Risques dorsolombaires pour l op rateur li s la manutention Comme pour tous les objets
29. nox Powerflow Flushing Machine MKIII 15 E hina Machine owerflow Flushing Machine MKIII Fernox Powerflow Flushing Machine MkIll 17 Initial Flush I E Rincage initial Anf ngliches Durchsp len E Lavaggio iniziale ZZ Eerste spoeling Purga inicial Lavagem inicial 25 Use Powerflow unit to replace existing system water with mains water until dump runs clear Maintain water level with mains fill and dump open Fernox Powerflow Flushing Machine MKIII H Utilisez l unit Powerflow MKIII pour remplacer l eau de l installation par de l eau de ville jusqu ce que l eau de vidange soit transparente Maintenez un d bit de vidange maximal tout en conservant un niveau d eau constant Verwenden Sie Powerflow MKIII zum Ersetzen des in der Anlage vorhandenen Wassers mit Hauptleitungswasser bis es klar herauslauft Beim Fullen von der Wasserhauptleitung bei offener Entleerungsoffnung den richtigen Wasserpegel aufrechterhalten Utilizzare la macchina Powerflow per cambiare l acqua presente negli impianti con l acqua di rete fino a quando lo scarico esce pulito Mantenere il livello dell acqua col riempimento di rete e scarico aperti Gebruik de Powerflow MKIII eenheid om het bestaande CV water te vervangen door leidingwater tot de afvoer schoon is Hou het waterpeil in stand met de leidingtoevoer en de afvoer open Use la unidad Powerflow MKII
30. ns de nettoyage afin que celles ci une fois expos es ne soit pas abim es par des d gats des eaux li s des fuites La pression d eau produite par la pompe Powerflow est limit e 2 3 bars 35 psi afin d viter que les composants du syst me ne soient abim s ce qui risquerait d entrainer des fuites Les op rateurs devront tout moment garder le contr le de l unit Powerflow pendant le fonctionnement de celle ci et la machine ne devra pas tre laiss e sans surveillance Risiko von Stromschlag und Lebensgefahr f r den Bediener Nur f r den Gebrauch in Innenr umen Die Fernox Powerflow Pumpe muss grunds tzlich ber eine Fehlerstrom Schutzeinrichtung an die Stromversorgung angeschlossen werden Eindringlich empfohlen wird die regelm ige Kontrolle von Netzkabel und Netzstecker Besch digte Bauteile sind vor dem Gebrauch auszuwechseln Der Powerflow Motor ist durch den Ein Aus Schalter und den Leistungsschutzschalter gegen Uberlast und Festfressen der Welle gesch tzt Vor jeder Demontage oder Wartungsarbeit muss die Maschine von der Netzstromversorgung getrennt werden Wartungsarbeiten d rfen nur von sachkundigem Personal und unter Verwendung neuer zugelassener Bauteile durchgef hrt werden Risiko von Verbr hung f r Bediener und Umstehende Da eine Hochtemperaturreinigung nachweislich erheblich bessere Reinigungsergebnisse bringt ist die Fernox Powerflow Pumpe f r den sicheren Betrieb bei einer Anlagentemperatu
31. orrecte dans vidange des eaux us es un puisard un jardin Sequenzfolge Dauer 3 Stunden Dauer 15 Minuten Wiederholen Flussrichtung Richtiges Dumping im Falsches Dumping Falsches Dumping im ochmutzwasserablauf Absickernt Garten B Ordine di sequenza Durata di tre ore Durata di 15 minuti Ripetere Direzione flusso Corretto scarico in Scarico incorretto nel suolo Scarico incorretto nel drenaggio di fogna giardino Volgorde Duur 3 uur Duur 15 minuten Herhalen Stroomrichting Correct afvoeren naar afvoer Foutief afvoeren naar Foutief afvoeren naar tuin wegsijpeling Orden de secuencia 3 horas de duraci n 15 minutos de duraci n Repetir Direcci n de flujo Vaciado correcto hacia Vaciado incorrecto para Vaciado incorrecto hacia desag e de aguas sucias empapado el jard n Ordem sequencial Duragao de 3 horas Durac o de 15 minutos Repetir Direcc o do fluxo Descarga correcta para Descarga incorrecta Descarga incorrecta para 0 esgoto para fossa 0 jardim Caution Caution Electricity Balance Watch Maintain level Wet working system Temperature B Attention Attention Electricit Equilibrer Observer Maintenir le niveau Travail en milieu mouill Temp rature du syst me Achtung Achtung Strom Ausgleich Vorsicht Niveau halten Nassarbeit Anlagentemperatur li E Attenzione Attenzione Elettricit Bilanciare Osservare Mantenere il livello Lavoro con acqua Temperatura impianto Opgelet Opgelet elektr
32. que o operador tenha contacto directo com a gua quente Quando desligar a m quina a gua quente pode ainda estar presente nas mangueiras 6 portanto deve se tomar cuidado para arrefecer 0 sistema antes de desligar a unidade Powerflow As pessoas que estiverem perto do sistema devem ser mantidas a uma dist ncia segura Risco ao operador com a manipula o Les o nas costas Quando se tratar de objectos grandes ou pesados deve se tomar cuidado para prevenir contra les o resultante de manuseamento A unidade vazia do Fernox Powerflow pesa 20 kg 44 Ibs e vem com pegadoiros para carregar e rodinhas para facilitar no transporte O peso total das mangueiras um adicional de 12 kg 26 Ibs O Powerflow deve ser esvaziado antes de movimentar ou transportar nos locais de utiliza o pois o peso da m quina cheia de gua acima de 50 kg 110 Ib Os operadores desta bomba devem estar cientes das suas capacidades de levantar e transportar esta unidade com seguran a Seguran a qu mica do operador Riscos de sa de associados com o contacto qu mico Seguran a s crian as e s pessoas que se encontram perto Siga sempre as normas de seguran a quando os produtos qu micos Fernox forem utilizados Mantenha sempre crian as e pessoas longe da m quina Powerflow das mangueiras e de todos os produtos qu micos Os operadores devem usar equipamento de protec o pessoal apropriado para manusear os produtos qu micos refira ao MSDS do produ
33. r bis zu 85 C konzipiert ohne dass der Bediener in direkten Kontakt mit heiBem Wasser kommt Beim Trennen der Maschine kann jedoch heiBes Wasser in den Schl uchen vorhanden sein Deshalb muss die Anlage vor dem Trennen der Powerflow Pumpe ausreichend abk hlen Umstehende Personen m ssen einen Sicherheitsabstand einhalten Risiko f r Bediener durch Heben Tragen R ckenverletzungen Wie bei allen groBen oder schweren Gegenstanden ist die Verletzungsgefahr beim Heben und Tragen zu vermeiden Die Fernox Powerflow Einheit wiegt im Leerzustand 20 kg und l sst sich mittels Tragegriff und Laufrollen gut transportieren Das Gesamtgewicht der Schl uche betr gt weitere 12 kg Die Powerflow ist zu entleeren bevor sie bewegt oder transportiert wird da sie ber 50 kg wiegt wenn sie mit Wasser gef llt ist Bediener m ssen sicherstellen dass sie f hig sind das Ger t sicher zu heben und zu transportieren Chemische Sicherheit des Bedieners Gesundheitsrisiken bei Kontakt mit Chemikalien Sicherheit von Kindern und Umstehenden Halten Sie grunds tzlich die Sicherheitshinweise zu den verwendeten Fernox Chemikalien ein Kinder und umstehende Personen m ssen immer von der Powerflow Maschine den Schl uchen und allen Chemikalien ferngehalten werden Generell m ssen Bediener die f r die Chemikalie geeignete Schutzausr stung verwenden siehe Sicherheitsdatenblatt und nach dem Gebrauch von Chemikalien die Hande waschen Besteht der Verdacht auf g
34. rmutador de calor s mangueiras de fluxo e de retorno dos cilindros de armazenagem t rmica da Powerflow Armazenagem t rmica Ligar a entrada sa da da serpentina permutador de calor s mangueiras de fluxo e de retorno da unidade Powerflow Limpar e fazer circular utilizando Fernox DS 3 Limescale Remover neutralizar e lavar 32 F RNO gt MAKES WATER WORK AR A _ A Fernox Forsyth Road Sheerwater service Commercial T l Tel 49 0 2173 8490 300 Tel 39 02 45339260 Tel 31 0 73 62 80 180 Woking Surrey GU21 5RZ 33 0 825 80 63 49 Fax 49 0 2173 8490 310 Fax 39 02 45339253 Fax 31 0 73 62 19 283 Tel 44 0 330 100 7750 fernox_germany alent com fernox_italy alent com fernox_netherlands alent com Fax 44 0 330 100 7751 Service Technique Tel 33 0 825 85 31 10 www fernox com Fax 33 0 825 09 79 40 salestofernox com fernox_france alent com Tel 44 0 330 100 7750 Tel 44 0 330 100 7750 Tel 32 0 14 44 50 00 Tel 1 814 940 3804 Fax 44 0 330 100 7751 Fax 44 0 330 100 7751 Fax 32 0 14 42 47 79 Technical 1 814 941 1687 fernox_spain alent com fernox_portugal alent com fernox_belgium alent com Fax 1 814 944 8094 fernox_usa alent com www fernox com
35. rper Tramite radiatore Via radiator V a el radiador Atrav s do radiador Via Pum a D l interm diaire de pompe EM KT 4 4 1 B Tramite pompa y Via pomp V a la bomba Atrav s da bomba Via Powerflow Pump Head Adapter Par Powerflow Pump Head Adapter uber Powerflow Pump Head Adapter Tramite Powerflow Pump Head Adapter Via Powerflow Pump Head Adapter Via Powerflow Pump Head Adapter Bk BU Atrav s Powerflow Pump Head Adapter Fernox Powerflow Flushing Machine MKIII 13 Connection B B Raccordement Anschluss E E Collegamento ZZ Aansluiting ZZ Conexi n EM Liga o 2 ly i ER Total Filter TF1 Flushing Adapter Par Total Filter TF1 Flushing Adapter Uber Total Filter TF1 Flushing Adapter Tramite Total Filter TF1 Flushing Adapter Via Total Filter TF1 Flushing Adapter Via Total Filter TF1 Flushing Adapter Atrav s Total Filter TF1 Flushing Adapter Via Boiler Buddy Par Boiler Buddy Uber Boiler Buddy Tramite Boiler Buddy Via Boiler Buddy Via Boiler Buddy Atraves Boiler Buddy Fernox Powerflow Flushing Machine MKIII q s iy Sw i SIS Connection to mains Connexion l eau de ville Anschluss an der Hauptwasserleitung ELE Collegamento alla rete Aansluiting op net ZZ Conexiones a la red EM Liga o a rede Fer
36. shing Adapter Raccordement Par Boiler Buddy Connexion l eau de ville Enl vement du bouchon du r servoir d alimentation et d expansion Royaume Uni seulement Mise en marche Ringage initial Ajoutez le produit nettoyant Fernox Cleaner F3 F5 DS40 et faites le circuler Rincez l installation afin de supprimer le nettoyant Fernox Cleaner F3 F5 DS40 Rincage individuel des radiateurs Rincage final de l installation Ajoutez l inhibiteur Fernox Protector F1 et faites le circuler D connectez l unit Powerflow MKIII et replacez la pompe Videz l unit Powerflow MKIII Equilibrez l installation D tartrage Glossar Informationssafety Informationen Produktinhalt Bestandteile vorne Bestandteile hinten Sauberkeit der Testanlage Anschluss der Anlagenschlauche AnschlieBen des Dumpingschlauchs AnschlieBen des berlaufschlauchs Anschluss ber Heizk rper Anschluss Uber Pumpe Anschluss ber Powerflow Pump Head Adapter Anschluss Uber Total Filter TF1 Flushing Adapter Anschluss Uber Boiler Buddy Anschluss an der Hauptwasserleitung Dosier und Ausgleichsbeh lter mit Kappe verschlieBen Betrieb Anfangliches Durchsp len Fernox Cleaner F3 F5 DS40 hinzufiigen und umlaufen lassen Fernox Cleaner F3 F5 DS40 aussp len Durchsp len einzelner Heizk rper Endg ltiges Durchsp len der Anlage Fernox Protector F1 hinzuf gen und umlaufen lassen Powerflow MKIII trennen und Pumpe wieder anbring
37. t from central heating systems should be disposed of safely in accordance with local Regulations and the specific instructions pertaining to the chemicals being used System effluent should never be allowed to enter or pollute surface and ground water The Fernox Powerflow MKIII is fitted with a double check valve on the mains water inlet to prevent back flow contamination of the water main by system effluent Risk of water damage to the property structure and furnishings To avoid water damage to the floors and furnishings on site it is recommended that the Powerflow MKIII is always used on a water proof groundsheet or in a bund tank to protect the property from water or chemical spills Regular inspection of the hoses and hose fittings is also highly recommended and damaged parts should be replaced before use The machine must always be used on a level surface Operators are advised to inspect all parts of the system regularly during cleaning to avoid water damage from leaks that may be exposed by cleaning The water pressure produced by the Powerflow MKIII is limited to 2 3 bars 35 psi to avoid risk of damage to system components that might otherwise lead to leaks Operators must remain in control of the Powerflow MKIII at all times during operation and the machine must not be left unattended Fernox Powerflow Flushing Machine MKIII H Risque d lectrocution et danger de mort pour l op rateur Appareil destin une utilisation e
38. tare attenzione ed attendere che l impianto si raffreddi prima di scollegare l unit Powerflow Gli astanti devono mantenere la distanza di sicurezza Rischi derivanti dalla manipolazione da parte degli operatori ed infortuni alla schiena Come per tutti i carichi ingombranti o pesanti necessario prestare attenzione per prevenire infortuni durante la manipolazione L unit Powerflow di Fernox pesa 20kg da vuota ed dotata di una maniglia e ruote per facilitarne il trasporto Il peso complessivo dei tubi equivale ad ulteriori 12kg L unit Powerflow deve essere svuotata prima di qualsiasi spostamento o trasporto verso il o dal sito poich se riempita d acqua raggiungere un peso di oltre 50kg Gli operatori devono accertarsi preventivamente di poter sollevare e trasportare l unit in tutta sicurezza Sicurezza chimica per gli operatori contatto con i prodotti chimici pu provocare rischi per la salute Sicurezza di bambini e astanti Seguire sempre le avvertenze di sicurezza in merito ai prodotti chimici Fernox utilizzati Tenere bambini e astanti lontani da macchinario tubi e qualsiasi prodotto chimico Powerflow in qualsiasi momento In generale gli operatori devono utilizzare un attrezzatura protettiva personale adeguata per la manipolazione dei prodotti chimici attenersi alle schede di sicurezza del prodotto e lavarsi le mani in seguito all uso di qualsiasi prodotto chimico Se si sospettano effetti avversi sulla salute
39. tif diff rentiel Die Fernox Powerflow Anlage wiegt 20 kg 44165 leer Das H chstgewicht der Anlage ist 54 kg 120lbs in Verwendung Die Fernox Powerflow Anlage wurde so konstruiert dass sie bei einer vollen Betriebstemperatur von 85 C 185 F sicher funktioniert ohne dass der Bediener in direkten Kontakt mit dem heiBen Wasser kommt Die Fernox Powerflow Anlage muss immer ber einen Fehlerstromschutzschalte r an der Stromversorgung angeschlossen sein L unit di Fernox Powerflow pesa 20kg 44lbs vuota Il massimo peso dell unit in uso di 54kg 120105 L unit Fernox Powerflow stato progettato per funzionare con sicurezza a piena temperatura dell impianto di 85 C 185 F senza che l operatore venga a contatto con l acqua molto calda L unit Fernox Powerflow deve sempre essere collegato all alimentazione elettrica tramite il Dispositivo Corrente Residua RCD 7 De Fernox Powerflow eenheid weegt 20 kg 44lbs in lege toestand Het maximale gewicht van de eenheid in gebruik bedraagt 54 kg 120105 De Fernox Powerflow eenheid werkt veilig bij de volle installatietemperatuur van 85 C 185 F zonder dat de gebruiker rechtstreeks in contact komt met heet water De Fernox Powerflow eenheid moet altijd via een differentieel blok worden aangesloten op de elektriciteitstoevoer 12Kg 26 5165 La unidad Fernox Powerflow pesa 20Kg 44lbs en vacio
40. tion boilers Connect with adaptors the water inlet and hot water outlet from the combination boiler to the flow and return hoses of the Powerflow MKIII unit Primary heat exchanger Connect with adaptors the inlet and outlet from the boiler heat exchanger to the flow and return hoses on the Powerflow MKIII Thermal store cylinders Thermal store Connect the inlet outlet from the coil heat exchanger to the flow and return hoses of the Powerflow MKIII unit Clean and circulate using Fernox DS 3 Limescale Remover neutralise and flush Fernox Powerflow Flushing Machine MKIII d eau chaude secondaire dans les chaudi res combin es A l aide d adaptateurs connectez l entr e d eau et la sortie d eau chaude de la chaudi re combin e aux tuyaux de flux et de retour de l unit Powerflow MKIII changeur thermique principal A l aide d adaptateurs connectez l entr e et la sortie de la chaudi re de l changeur thermique aux tuyaux de flux et de retour des cylindres de l accumulateur de chaleur Powerflow MKIII Accumulateur de chaleur Connectez l entr e et la sortie du serpentin de l changeur thermique aux tuyaux de flux et de retour de l unit Powerflow MKIII Nettoyez l installation avec Fernox DS 3 Limescale Remover et faites le circuler Neutralisez l installation et rincez la warmeaustauscher fur Warmwasser in Kombiboilern Den Wasserzulauf und den Warmwasserauslauf vom Kombiboiler m
41. to e lavar as m os ap s o manuseamento de qualquer produto qu mico Se suspeitar de algum efeito adverso na sa de com 0 produto procure imediatamente por conselho m dico Risco ao meio ambiente com os efluentes da limpeza Todo efluente dos sistemas de aquecimento central deve ser eliminado com seguran a de acordo com os Regulamentos e instru es espec ficas locais relativas ao produto qu mico utilizado O efluente do sistema nunca deve poluir a superf cie nem juntar gua subterr nea O Fernox Powerflow vem instalado com uma v lvula de controlo duplo no orif cio de admiss o da gua para prevenir contamina o do efluente por recuo de fluxo no sistema de gua Risco de danos causados com a gua na estrutura e nos mobili rios da propriedade Para evitar danos com a gua nos soalhos e nas mob lias recomenda se que o Powerflow seja utilizado sempre sobre um material imperme vel ou dentro de um tanque de conten o a fim de proteger a propriedade contra um vazamento qu mico ou de gua Recomenda se que uma inspec o regular seja efectuada nas mangueiras e tamb m nos seus acess rios As pe as danificadas devem ser substitu das antes da utiliza o A m quina deve ser utilizada sempre sobre uma superf cie nivelada Recomenda se que os operadores inspeccionem regularmente todas as pe as do sistema durante a limpeza a fim de evitar danos com vazamentos de gua que podem ficar expostos com a limpeza A press
42. tos until water runs clear d charge jusqu a ce que zwei Minuten umkehren bis a quando esce pulita leeglopen om tot het water hasta que el agua salga durante a descarga at a soit claire das Wasser klar ist schoon is limpia agua sair incolor Fernox Powerflow Flushing Machine MKIII 22 SIS Individual Radiator Flush ELE Rincage individuel des radiateurs W Durchsp len einzelner Heizk rper Lavaggio singolo del radiatore Individuele radiator spoelen E Purga individual de los radiadores Lavagem individual de radiadores Fernox Powerflow Flushing Machine MKIII 23 N L Sequence order E Ordre de la s quence Sequenzfolge E Ordine di sequenza Volgorde Orden de secuencia Ordem sequencial lt x SO O x lt E i LH Flush radiators individually Rincez les radiateurs Heizkorper einzeln Lavare i radiatori Spoel radiatoren individueel Purgue los radiadores Lavar os radiadores Reverse flow every two individuellement Inversez le durchspulen Die individualmente Invertire Keer de stroming om twee individualmente Invierta individualmente Inverter a minutes Dump until water flux toutes les deux minutes Durchflussrichtung alle il flusso ogni 2 minuti minuten om Laat leeglopen el flujo cada dos minutos direcgao do fluxo a intervalos runs Clear Effectuer la
43. u Lecks f hren k nnten Betreiber m ssen die Powerflow w hrend des Betriebs jederzeit unter Kontrolle halten und d rfen die Maschine nicht unbeaufsichtigt lassen H Rischio di elettrocuzione e pericolo di morte gli operatori Solo per uso interno La pompa Powerflow di Fernox deve essere sempre collegata all alimentazione elettrica mediante l interruttore differenziale RCD Si raccomanda vivamente di ispezionare il cavo e la spina elettrica ad intervalli regolari Le parti danneggiate devono essere sostituite prima dell uso Il motore Powerflow protetto dal rischio di sovraccarico e di bloccaggio dell albero dall interruttore di accensione spegnimento dall interruttore di circuito Il macchinario deve essere fisicamente scollegato dall alimentazione elettrica prima di poter essere smontato o revisionato Tutte le operazioni di manutenzione devono essere effettuate da personale competente utilizzando soltanto parti nuove ed approvate Rischio di scottature per operatori e astanti La pulitura ad alta temperatura ha dimostrato di migliorare notevolmente le prestazioni di pulizia pertanto la pompa Powerflow di Fernox concepita per operare in tutta sicurezza ad una temperatura di sistema pari a fino 85 C 185 senza che l operatore entri a contatto diretto con l acqua calda Tuttavia quando il macchinario viene scollegato potrebbe verificarsi la presenza di acqua calda nei tubi quindi amp necessario pres
44. ures umkehren uur om durante 1 a 2 horas Note If necessary isolate and Nota Se necessario isolare Nota Si fuera necesario clean individual radiators Remarque isolez et Hinweis Soweit erforderlich e pulire individuali radiatori Opmerking Indien nodig aisle y limpie cada radiador Nota Se necessario isolar nettoyez les radiateurs die einzelnen Heizkorper isoleert en reinigt u individual e limpar os radiadores individuellement le cas trennen und reinigen individuele radiatoren individuais ch ant Fernox Powerflow Flushing Machine MKIII 20 Flush Out Fernox Cleaner F3 F5 DS40 E E Rincez l installation afin de supprimer le nettoyant Fernox Cleaner F3 F5 DS40 Fernox Cleaner F3 F5 DS40 aussp len E E Lavare con il Fernox Cleaner F3 F5 DS40 Spoel Fernox Cleaner F3 F5 DS40 uit Purgue Fernox Cleaner F3 F5 DS40 EB Drenar o Fernox Cleaner F3 F5 DS40 O Fernox Powerflow Flushing Machine MKIII 21 Sequence order M Ordre de la s quence Sequenzfolge E Ordine di sequenza Volgorde Orden de secuencia Ordem sequencial H i EN Reverse flow every two Inversez le flux toutes les Die Durchflussrichtung Invertire il flusso ogni due Keer de stroming om de Invierta el fl ujo cada dos Inverter a direcc o do fluxo minutes during dump deux minutes pendant la w hrend des Entleerens alle minuti durante lo scarico fino twee minuten tijdens het minutos durante la descarga a intervalos de dois minu
Download Pdf Manuals
Related Search
Related Contents
Triarch 75141 User's Manual La nouvelle version du manuel d`utilisation du contingent CF GAS 208D rev7 ft:pedia - fischertechnik Community Collimator Locking Mechanism Safety FAS住まい新聞 DeLOCK Cable Power SATA HDD 2x > 4pin male アクセサリーカタログ IMC Networks IE-MiniFiberLinX-II w/ TELCO Power Copyright © All rights reserved.