Type UTCG, UCCG, UCDG INSTRUCTIONS

image

Contents

1. de 0 C 40 C de 32 F 104 F GRC capas sesss de 35 C 65 C de 31 F 149F OJ Electronics A S Stenager 13B DK 6400 Sonderborg Tel 45 73 12 13 14 Fax 45 73 12 13 13 oj oj dk www oj dk Espa ol El termostato es un dispositivo de ON OFF encendido apagado para el control de temperatura por medio de un sensor NTC colocado dentro o fuera del termostato El termostato tiene integrado un interruptor de circuito de fallo a tierra Ground Fault Circuit Interrupter GFCI Clase A El termostato y el GFCI es un modelo doble y adecuado para alimentaci n el ctrica de 120 240 V 50 60 HZ El termostato es para montaje a ras en un recept culo de pared Programa de productos Termostatos con GFCI integrado UTCG 9991 UTCG 9999 Incluido el sensor de piso 3 m Con sensor de temperatura ambiente integrado Termostatos con reloj y GFCI integrado terminales de linea del termostato con las marcas L1 y L2 Cable de la carga Suministra alimentaci n el ctrica desde el termostato hasta el cable calefactor Este cable se ha de conectar solamente a los terminales de carga del termostato con la marca de carga 16 A 1 Use un destornillador para abrir la cerradura fig 1 y retire el bastidor 2 Conecte los cables de acuerdo con el diagrama fig 2 3 El termostato se instala en el recept culo de pared Se vuelven a colocar los bastidores Sensor de temperatura El sensor de
2. 12 13 13 oj oj dk www oj dkF Fig 1 Fig 2 BR928A06 BR928A05B o o ff JAN ae i 1 4 Strip length D RARRA oO AAAAAAAAN Y Fig 3 Fig 4 BR928A02 Fig 5 Sensor _0 32 38000 BR928A07 20 68 14800 3o 9700 57609
3. CALEFACCI N EN EL PANEL PRINCIPAL DE ALIMENTACI N EL CTRICA PARA EVITAR LAS DESCARGAS EL CTRICAS MANTENGA LIMPIAS Y SIN OBSTRUCCIONES LAS REJILLAS DE VENTILACI N DEL TERMOSTATO Este termostato es un producto el ctrico y deber instalarse de conformidad con las especificaciones de los c digos el ctricos locales o nacionales Donde la ley as lo requiera la instalaci n deber realizarla nicamente el personal calificado El termostato est equipado con un interruptor de circuito de fallo a tierra GFCI Clase A el cual requiere que la l nea y la carga est n aisladas una de la otra para lograr el funcionamiento correcto La carga resistiva no debe exceder 16 A 1920 W a 120 V CA 3840 W a 240 V CA Durante un fallo a tierra se desconectar n ambas l neas Cable de la l nea Lleva la alimentaci n el ctrica desde el panel de servicio panel de disyuntores o caja de fusibles hasta el termostato Este cable se ha de conectar solamente a los e El a Funcionamiento Con reloj integrado tipo UCCG y UCDG La primera vez que se conecta el termostato sera necesario establecer la hora y el dia AV y Ajuste de la hora el reloj parpadea durante el ajuste AV V Ajuste del dia el indicador de dia parpadea durante el ajuste Sin reloj integrado tipo UTCG Se muestra el ajuste real de la temperatura y el termostato esta listo para el uso Verificaci n del GFCI Es importante inspeccionar
4. INSTRUCTIONS Type UTCG UCCG UCDG 57609 10 07 BJ English The thermostat is an electronic on off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat The thermostat has integrated a Ground Fault Circuit Interrupter GFCI Class A The thermostat and the GFCI is a dual model suitable for 120 240 V 50 60 Hz supply The thermostat is for flush mounting in a wall socket Product program Thermostats with built in GFCI UTCG 9991 Incl floor sensor 3 m UTCG 9999 With built in room sensor Clock thermostats with built in GFCI UCCG 9991 Incl floor sensor 3m UCCG 9999 With built in room sensor UCDG 9999 With 2 sensors built in room sensor and incl floor sensor 3m Mounting of floor sensor fig 3 The floor sensor is used for temperature regulation in floor surfaces For easy replacement the sensor can be mounted in a tube which is placed between 2 heating cables The tube is ended towards the floor surface and sealed If required the sensor cable can be extended up to about 100 m with a standard installation cable 2 leads in a multi lead cable which is used as supply cable for the heating cable must not be used Mounting of thermostat with built in sensor fig 4 The room sensor is used for comfort temperature regulation in rooms The thermostat is mounted on the wall with free air circulation about 1 6 m above the floo
5. O to 40 C 32 to 104 F GRC putos 35 to 65 C 31 to 149 F OJ Electronics A S Stenager 13B DK 6400 Sonderborg Tel 45 73 12 13 14 Fax 45 73 12 13 13 oj oj dk www oj dk Type UTCG UCCG UCDG Fran ais Le thermostat est du type lectronique action par tout ou rien qui r gule la temp rature au moyen d un capteur NTC plac soit l ext rieur soit l int rieur du thermostat Il est dot d un disjoncteur de fuite la terre GFCI de classe A Le thermostat et le GFCI sont compatibles aux modes d alimentation 120 240 V 50 60 Hz Ce mod le a t con u pour tre encastr dans une prise murale Programmation du produit Thermostats avec disjoncteur de fuite la terre int gr UTCG 9991 avec capteur de plancher 3 m UTCG 9999 avec capteur de pi ce Thermostats affichant l heure avec disjoncteur de fuite la terre int gr UCCG 9991 avec capteur de plancher 3 m UCCG 9999 avec capteur de pi ce UCDG 9999 avec deux capteurs un capteur de pi ce et un capteur de plancher 3 m Montage du capteur de plancher fig 3 Le capteur de plancher sert r guler la temp rature de surface d un plancher Afin de faciliter son remplacement on peut monter le capteur dans un tube que l on placera entre deux c bles chauffants L extr mit du tube doit tre situ e la surface du plancher et scell e Au besoin la longueur du c ble du capteur dans une installation stand
6. ard peut aller jusqu 100 m On ne peut amener l alimentation lectrique sur le m me c ble multiconducteur dont l un des conducteurs est le c ble chauffant Montage du thermostat dot d un capteur de mesure int gr fig 4 Le capteur de pi ce sert r guler la temp rature dans une pi ce Le thermostat doit tre plac sur un mur dans un endroit o l air est libre de circuler environ 1 6 m au dessus du plancher De plus il doit tre plac l cart des courants d air de la lumi re directe du soleil ou de toute autre source de chaleur directe On ne doit y connecter aucun capteur externe Montage du thermostat Installation COUPEZ L ALIMENTATION AU SYST ME DE CHAUFFAGE PARTIR DU TABLEAU D ALIMENTATION PRINCIPALE POUR PR VENIR LES RISQUES DE SECOUSSE LECTRIQUE GARDEZ LES VENTS DU THERMOSTAT PROPRES ET EXEMPTS D OBSTACLES Ce thermostat est un appareil lectrique qui doit tre install en conformit avec le code national ou r gional d lectricit L o la loi le prescrit un lectricien qualifi doit en effectuer l installation Le thermostat est dot d un disjoncteur de fuite la terre de classe A qui n cessite que les lignes d alimentation et de charge soient isol es l une de l autre pour en assurer le bon fonctionnement La charge r sistive ne doit pas d passer 16 A 1 920 W 120 V c a ou 3 840 W 240 V c a Si la mise la masse est d fectueuse les deux ligne
7. cas contraire il y a effectivement une mise la masse d fectueuse V rifiez le c ble chauffant le c ble du capteur et le thermostat puis remplacez la pi ce d fectueuse Programmation Voir le guide de l utilisateur Localisation de la d faillance Si le capteur est d connect ou court circuit le syst me de chauffage est coup On peut v rifier le capteur en se r f rant au tableau des r sistances 5 Codes d erreur EO Erreur interne Remplacez le thermostat E1 Le capteur interne est court circuit ou d connect Remplacez le thermostat E2 Le capteur externe est court circuit ou d connect C UL LISTED En accord avec les normes suivantes GFCI UL 943 CSA C22 2 No 144 M91 Thermostat UL 873 CSA C22 2 No 24 Num ro de fichier UL E157297 Classification Le produit est un appareil de classe Il isolement renferm et il doit tre connect aux conducteurs suivants Phase L L1 240 V 15 50 60 Hz ou 120 V 15 50 60 Hz Neutre N L2 Charge max 16A Les bornes conviennent a des fils de grosseur 12 AWG a 22 AWG Fiche technique Alimentation 120 240 V c a 50 60 Hz Charge 16 maximum charge r sistive Puissance 1 920 W 120 V c a 3 840 W 240 V c a GFG TT Classe A seuil de d clenchement r gl 5 mA Plage de temp rature de 5 C 40 C de 40 F 104 F Plage de temp rature ambiante Thermostat
8. el GFCI y verificar que est instalado y funcionando correctamente Para inspeccionar el GFCI Se puede realizar las pruebas solamente si el termostato tiene una demanda de calefacci n Calibre el punto de ajuste hasta que aparezca el s mbolo SSS use el bot n para aumentar la demanda de calefacci n Espere 10 segundos para dejar que el termostato funcione de acuerdo con el nuevo punto de ajuste Pulse el bot n TEST La prueba es concluyente si se enciende la luz indicadora roja en el termostato y desaparecen los simbolos en la pantalla Si esto no ocurre verifique la instalaci n Pulse el bot n RESET Restablecer para restablecer el GFCI La luz roja deber desaparecer y la pantalla recuperar la apariencia normal Pulse el bot n ok aceptar para cancelar la temperatura establecida previamente Si falla la prueba verifique su cable calefactor y el termostato Se recomienda probar mensualmente el GFCI Si el GFCI se dispara en funcionamiento normal sin pulsar el bot n de prueba TEST iquiz haya un fallo a tierra Para verificar si existe un fallo a tierra o un disparo de interferencia pulse RESET Si esto causa que se apague la luz y no se vuelve a encender se trataba de un disparo de interferencia y el sistema est funcionando Si esto no se puede realizar jexiste un fallo a tierra Inspeccione el cable calefactor el cable del sensor y el termostato Cambie la pieza defectuosa Programaci
9. marked sensor Push with a screwdriver on the terminal spring and mount the wires 2 E 3 x E Operation With integrated clock type UCCG and UCDG The first time the thermostat is connected time and day must be set Setting of time the clock flashes SS AVN during setting Setting of day day flashes during LE AVN setting Without integrated clock type UTCG Actual temperature setting is shown and the thermostat is ready for use Checking GFCI It is important that the GFCI has been checked for correct installation and function To check the GFCI Testing can only be performed if the thermostat has a heating demand Adjust the set point until the heating symbol SSS appears use the A to increase the heating demand Wait 10 sec to let the thermostat work according to the new set point Press the button TEST The test is conclusive if the red light on the thermostat lightens and the display signs disappear If this does not occur check the installation Press on RESET button to reset the GFCI The red light should disappear and the display will return to normal appearance Push ok accept button V to cancel the previously set temperature If the test fails check your heating cable and the thermostat The GFCI test should be carried out monthly If the GFCI trips in normal operation without pressing the TEST button there could be a ground fault To check whether it is a ground fault o
10. n V ase el manual del usuario Ubicaci n del fallo Si el sensor se desconecta o entra en cortocircuito se desconecta el sistema de calefacci n Se debe verificar el sensor de acuerdo con la tabla de resistencias de la fig 5 C digos de error EO Error interno Es necesario cambiar el termostato E1 Sensor integrado en cortocircuito o desconectado Es necesario cambiar el termostato E2 Sensor externo en cortocircuito o desconectado LISTADO EN C UL De acuerdo con las normativas siguientes GFCI UL 943 CSA C22 2 No 144 M91 Termostato UL 873 CSA C22 2 No 24 N m de archivo UL E157297 Clasificaci n El producto es un dispositivo clase Il aislamiento con caracter sticas mejoradas y el producto se deber conectar a los siguientes conductores Fase L L1 240 V 15 50 60 Hz o 120 V 15 50 60 Hz Neutro N L2 Carga m x 16 A Los terminales son apropiados para el cableado de campo con conductores 12 AWG a 22 AWG Datos t cnicos Alimentaci n 120 240 V CA 50 60 Hz Carga 16 A como m ximo carga resistiva Potencia 1920 Wa 120 V CA 3840 W a 240 V CA GFCI Clase A nivel de disparo de 5 mA Rango de temperatura 5 a 40 C 40 a 104 F Rango de temperatura ambiente Termostato 0 a 40 C 32 a 104 F GFOL uai rotates 35 a 65 C 31 a 149 OJ Electronics A S Stenager 13B DK 6400 Sonderborg Tel 45 73 12 13 14 Fax 45 73
11. piso est conectado a los terminales sin tornillo con la marca de sensor Para instalar los cables emp jelos con un destornillador en el resorte del terminal UCCG 9991 Incluido el sensor de piso 3m UCCG 9999 Con sensor de temperatura ambiente integrado UCDG 9999 Con 2 sensores sensor de temperatura ambiente integrado y sensor de piso 3 m Montaje del sensor de piso fig 3 El sensor de piso se utiliza para el ajuste de temperatura en superficies de piso Para el f cil reemplazo del sensor se puede instalarlo en un tubo que se coloca entre 2 cables de calefacci n El tubo se termina en direcci n a la superficie del piso y se sella Si es necesario el cable del sensor se puede extender hasta un m ximo de 100 m con un cable de instalaci n est ndar No se debe utilizar 2 conductores en un cable con varios conductores el cual se utilice como cable de alimentaci n el ctrica para el cable calefactor Montaje del termostato con sensor integrado fig 4 El sensor de temperatura ambiente se utiliza para la regulaci n de la temperatura de confort en las habitaciones El termostato se instala en la pared con circulaci n libre de aire a aproximadamente 1 6 m sobre el piso Es necesario evitar las corrientes de aire la luz solar directa y cualquier otra salida de calefacci n directa No se debe conectar ning n sensor externo Montaje del termostato Instalaci n APAGUE LA ALIMENTACI N EL CTRICA DEL SISTEMA DE
12. r Draught direct sunlight or any other direct heating outlet must be avoided No external sensor is to be connected Mounting of thermostat Installation TURN OFF THE POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK KEEP AIR VENTS OF THE THERMOSTAT CLEAN AND OBSTRUCTION FREE This thermostat is an electrical product and must be installed in conformity with the National and or Local Electrical Code The installation must be performed by qualified personnel where required by law The thermostat is equipped with a ground fault circuit interrupter GFCI Class A which require that the line and load is isolated from each other for correct operation The resistive load must not exceed 16A 1920W at 120Vac 3840W at 240Vac During a ground fault the two lines will be cut off Line Cable Delivers power from the service panel breaker panel or fuse box to the thermostat This cable shall only be connected to the thermostat s line terminals marked L1 and L2 Load Cable Delivers power from the thermostat to the heating cable This cable shall only be connected to the thermostat s load terminals marked load 16A 1 Use a screwdriver to open the lock fig 1 and remove the frame 2 Connect cables according to the diagram fig 2 3 The thermostat is mounted in the wall socket The frame are remounted Temperature sensor The floor sensor is connected to the screw less terminals
13. r a nuisance tripping press RESET If this cause the red light to shot off and not comes on again it was a nuisance tripping and the system is functioning If this cannot be done there is a ground fault Check your heating cable the sensor cable and the thermostat Exchange the defective part Programming See user s manual Fault location If the sensor is disconnected or short circuited the heating system is cut out The sensor can be checked according to the resistance table fig 5 Error codes EO Internal error The thermostat must be replaced E1 Built in sensor short circuited or disconnected The thermostat must be replaced E2 External sensor short circuited or disconnected C UL LISTED According to the following standards GFCI UL 943 CSA C22 2 No 144 M91 Thermostat UL 873 CSA C22 2 No 24 UL file number E157297 Classification The product is a class Il device enhanced insulation and the product must be connected to the following leads Phase L L1 240 V 15 50 60 Hz or 120 V 15 50 60 Hz Neutral N L2 Load max 16A The terminals are suitable for field wiring of 12 AWG to 22 AWG conductors Technical Data SUPpIy nata aas das 120 240 Vac 50 60 Hz Load iii 16A maximum resistive load POWEF ass ss anses 1 920 W at 120 Vac Dr dd dd 3 840 W at 240 Vac GEGIL annee Class A 5 mA trip level Temperature range 5 to 40 C 40 to 104 F Amb Temperature range Thermostat
14. s seront coup es Ligne d alimentation Alimente le thermostat partir du tableau de distribution Cette ligne d alimentation ne doit tre connect e qu aux bornes d entr e L1 et L2 du thermostat Ligne de charge Alimente le c ble chauffant partir du thermostat Cette ligne de charge ne doit tre connect e qu aux bornes de sortie de 16 A du thermostat identifi es load 1 Ouvrez le dispositif de verrouillage l aide d un tournevis fig 1 puis d posez le b ti 2 Branchez les fils selon le diagramme fig 2 3 Installez le thermostat dans une prise murale puis replacez le b ti Capteur de temp rature Le capteur de plancher est branch aux bornes sans vis identifi es sensor Poussez sur le ressort de la borne l aide d un tournevis et connectez les fils e q D x oO Mode d emploi Mod les UCCG et UCDG avec horloge int gr e Il faut r gler l heure et la date la premi re utilisation du thermostat R glage de l heure l affichage de AVV l heure clignote durant le r glage R glage du jour l affichage du gt AVV jour clignote durant le r glage Mod le UTCG sans horloge int gr e Le r glage de temp rature actuel est affich et le thermostat est pr t tre utilis V rification du disjoncteur de fuite la terre GFCI ll est important de v rifier l installation et le fonctionnement du disjoncteur de fuite la terre Test du di
15. sjoncteur Pour v rifier le fonctionnement du disjoncteur il faut qu il y ait une demande de chauffage au thermostat R glez la demande de chauffage au thermostat jusqu ce que le symbole SSS s affiche Servez vous de la touche A pour augmenter la demande Patientez dix secondes pour laisser le thermostat s adapter la nouvelle demande Appuyez ensuite sur la touche TEST Le test est concluant si le voyant rouge du thermostat s allume et que les signes sur l affichage disparaissent Dans le cas contraire v rifiez l installation Appuyez sur la touche RESET pour r initialiser le disjoncteur de fuite la terre Le voyant rouge devrait s teindre et l affichage revenir la normale Appuyez sur la touche d acceptation Y pour annuler le r glage de temp rature pr c dent Si le test choue v rifiez le c ble chauffant et le thermostat Le test du disjoncteur de fuite la terre devrait tre effectu mensuellement Si le disjoncteur se d clenche en mode de fonctionnement normal sans qu il soit n cessaire d appuyer sur la touche TEST cela pourrait indiquer la pr sence d une mise la masse d fectueuse Pour v rifier s il s agit d une mise la masse d fectueuse ou d un d clenchement intempestif appuyez sur la touche de r initialisation RESET Si le voyant rouge s teint et qu il ne se rallume pas il s agissait d un d clenchement intempestif et le syst me fonctionne correctement Dans le