heavy duty suction pump bomba de succión de uso pesado pompe

image

Contents

1. F 0 40 C 95 RH 10 2 15 4 psi 70 106 kpa 14 158 F 10 70 C O 95 7 3 15 4 psi 50 106 kpa Miniature Glass Fuse 5x20mm Fast Blow Quick Acting F2A 250 V With respect to protection from electric shock Class warranty Two Years Limited Warranty The compressor portion of the DRIVE Medical Suction Unit is warranted to be free from defective workmanship and materials for a period of two years from date of purchase and six months on accessories Any defective part s will be repaired or replaced at DRIVE Medical option if the unit has not been tampered with or used improperly during that period Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions If repair is necessary please contact your medical equipment dealer NOTE This warranty does not cover providing a loaner unit compensating for costs incurred in rental while said unit is under repair or costs for labor incurred in repairing or replacing defective part s THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS P
2. Humedad de almacenamiento Presi n atmosf rica de almacenamiento Especificaciones del fusible Clasificaciones de equipo L 375 x Ancho 175 x Altura 250 mm 14 8 x 6 8 x 24 89 pulgadas 5 5 kg 12 1 lb 560 3 mm Hg gt 40 LPM lt 58 dBA CA 115 V 60Hz 70 watts 0 45 micrones 800 ml cc 32 104 F 0 40 C 95 RH 10 2 15 4 psi 70 106 kpa 14 158 F 10 70 O 95 7 3 15 4 psi 50 106 kpa Fusible miniatura de vidrio 5x20mm Fusible de accion rdpida F2A 250 V Con respecto a protecci n de descarga el ctrica Clase garantia Dos A os de Garantia Limitada La parte del compresor de la unidad de succion DRIVE Medical est garantizada contra defectos de fabricaci n y materiales por un periodo de dos a os a partir de la fecha de compra y seis meses en accesorios Cualquier Las parte s defectuosa s ser n reparada s o reemplazada s a discreci n de Drive Medical si la unidad no ha sido alterada o se ha utilizado inadecuadamente durante ese periodo Aseg rese que cualquier mal funcionamiento no se deba a una limpieza inadecuada o al descuido de no seguir las instrucciones Si necesita reparaci n por favor p ngase en contacto con su distribuidor de equipo m dico NOTA Esta garant a no incluye proporcionar una unidad prestada compensar por gastos incurridos en renta de otra unidad mientras su unidad est siendo reparada o gastos de mano de obra incu
3. Les lois f d rales exigent que cet appareil soit vendu par un m decin ou un autre professionnel de la sant ou sa demande poss dant un permis de pratique dans l tat ou la province per mettant d utiliser ou de prescrire l utilisation d un tel appareil NOTE Examinez TOUTES les pi ces pour d celer la pr sence de dommages dus au transport Le cas ch ant n utilisez PAS l appareil Communiquez avec votre fournisseur d quipement m dical pour conna tre la marche suivre renseignements concernant la s curit O 1 RENSEIGNEMENTS CONCERNANT LA S CURIT Prenez toujours des pr cautions l mentaires lorsque vous utilisez des appareils lectriques surtout en pr sence d enfants Lisez toutes les instructions avant d utiliser cet appareil Ces symboles identifient des renseignements particuli rement importants DANGER Renseignement concernant des aspects relatifs la s curit qui visent viter des blessures ou un d c s AVERTISSEMENT Renseignement concernant des aspects relatifs la s curit qui visent viter des blessures graves N MISE EN GARDE Renseignement concernant des aspects relatifs la s curit qui visent viter des dommages l appareil ZN NOTA Renseignements auxquels vous devriez porter attention lisez ce guide de l utilisateur avant d utiliser l appareil conservez ce guide Z DANGER Pour diminuer le risque d lectrocution 1 N utilisez pas cet
4. L ENTRETIEN DE CET POMPE ASPIRATRICE Z DANGER Cette pompe aspiratrice robuste est un appareil d aspiration vide con u pour le pr l vement de fluides ininflammables dans des applications m dicales seulement Un usage inad quat lors d une intervention m dicale peut causer des blessures ou un d c s Pour toutes les applications m dicales 1 Tous les pr l vements doivent tre effectu s en parfaite conformit aux proc dures institu es par du personnel m dical 2 Certains quipements ou accessoires peuvent ne pas s ajuster ad quatement au tube fourni Tous les quipements et accessoires doivent faire l objet d une v rification l gard de l ajustement avant d tre utilis s 2 ALIMENTATION LECTRIQUE CA ZN MISE EN GARDE L article No 18600 est quip d un bloc d alimentation qui fournit une alimentation de 115 V CA 60 Hz Cependant il doit tre branch une source lectrique ad quate 3 LECTRICIT Compresseur Si le protecteur contre les surcharges se d clenche souvent il est possible que la tension lec trique soit trop faible Une tension lectrique trop faible peut aussi causer les sympt mes suivants 1 Le moteur ne fournit pas la pleine puissance ou vitesse 2 D autres appareils motoris s pr sentent des sympt mes semblables Un trop grand nombre d appareils motoris s sont branch s au m me circuit ZN NOTA Le moteur de ce compresseur comporte un m canisme de protection
5. appareil pendant le bain 2 Ne placez pas cet appareil un endroit d o il pourrait tre tir et tomber dans un bain ou un lavabo 3 Ne placez pas cet appareil et ne l chappez pas dans l eau ou dans un autre liquide A Ne tentez pas de r cup rer l appareil s il est tomb dans l eau D branchez le imm diatement ZA AVERTISSEMENT Pour diminuer le risque de br lure d lectrocution d incendie ou de blessure 1 Une supervision tr s stricte est n cessaire lorsque cet appareil est utilis en pr sence d enfants ou de personnes affect es d un handicap physique N utilisez cet appareil que pour l usage pr vu comme d crit dans ce guide N utilisez jamais cet appareil si sa fiche ou son cordon d alimentation lectrique est endommag s il ne fonctionne pas correctement s il est tomb ou est endommag s il est tomb dans l eau Rapportez l appareil un centre de service Drive autoris pour qu il soit examin et r par Eloignez le cordon d alimentation des sources de chaleur Cet appareil ne doit jamais tre utilis par une personne endormie ou somnolente om han TAaWN renseignements concernant la s curit A AVERTISSEMENTS SP CIFIQUES POUR DIMINUER LES RISQUES D ELECTROCUTION OU DE BLESSURES NE TENTEZ PAS DE D MONTER CET APPAREIL SI VOUS TENTEZ DE D MONTER OU DE R PARER LAPPAREIL VOUS AUGMENTEZ SENSIBLEMENT LES RISQUES D LECTROCUTION SEULS DES TECH NICIENS QUALIFIES PEUVENT EFFECTUER
6. botella de recolecci n llega al nivel de seguridad de llenado 2 Al transportar la unidad gire en todo momento la perilla de ajuste de vaci en sentido de las man ecillas del reloj por si la unidad se cae ZN PRECAUCI N 1 Cuando se activa el flotador de cierre entonces se tienen que vaciar el material de la botella de recolecci n El dejar que la succi n siga ejerciendo puede da ar la bomba de vac o 2 Si por cualquier raz n el fluido se aspira dentro de la unidad mande su bomba de succi n a un centro de servicio autorizado para una inspecci n detallada ya que es probable que la bomba de vac o se haya da ado Impleza Limpieza de la botella de recolecci n 1 Apague la unidad de succi n y permita que el vac o disminuya luego desconecte la fuente de ali mentaci n de CA 2 Con la botella de recolecci n todav a en el sujetador retire la tapa de la botella de recolecci n Ahora puede sacar la botella del sujetador para vaciarla NOTA La botella de recolecci n debe de vaciase despu s de cada uso 3 La botella de recolecci n debe de limpiarse a profundidad despu s de cada uso siguiendo uno de los siguientes tres m todos a L vela en una soluci n de agua caliente detergente para lavar trastes y enju guela con agua potable caliente Luego l vela en una soluci n de una parte de vinagre con tres partes de agua caliente Enju guela con agua potable caliente y d jela secar al aire b Lavar co
7. contre les surcharges thermiques Le m canisme de protection arr te le moteur lorsque celui ci surchauffe Le cas ch ant mettez l appareil hors tension et laissez le refroidir environ 5 minutes Red marrez le compresseur S il ne red marre pas attendez 5 minutes suppl mentaires avant la prochaine ten tative Si cela ne fonctionne toujours pas v rifiez l tat du fusible de l appareil Si le fusible n est pas en cause communiquez imm diatement avec votre fournisseur d quipement renseignements concernant la s curit O AVERTISSEMENT Vous devez utiliser cet appareil comme prescrit pour liminer les risques de blessures Un usage inad quat peut causer des blessures ou des l sions Cet appareil ne doit tre utilis que par des personnes qui ont re u une formation d un m decin ou d un personnel m dical qualifi Apprenez d abord le fonctionnement de l appareil Placez l appareil sur une table et appliquez une forte pression pour faire en sorte que les pattes de type ventouse assurent une bonne prise Avant de brancher le cordon d alimentation dans une prise de courant assurez vous que l interrupteur est la position ARR T OFF NOTA Ne d marrez pas l appareil s il est froid Attendez qu il atteigne la temp rature de la piece Introduction Votre pompe aspiratrice robuste est un appareil d aspiration m dical professionnel qui produit une succion d au plus 560 mm Hg Cet appareil est quip d un colle
8. AS VOTRE SITUATION Cette garantie vous donne des droits sp cifiques et vous pouvez avoir d autres droits qui varient d un tat l autre Au besoin contactez votre revendeur autoris Drive www drivemedical com 2 O s lt gt a Lu 2 LU E a z 3 5 gt A WWW DRIVEMEDICAL COM 99 Seaview Boulevard Port Washington NY 1050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com
9. CA PRECAUCI N Art culo 18600 se usa con una fuente de alimentaci n que permite una operaci n de voltaje de CA 115 VCA 60 Hz Sin embargo se debe de utilizar la fuente de alimentaci n correcta para conectarlo a una fuente de energ a de la pared 3 SISTEMA EL CTRICO Compresor Si el protector de sobrecarga apaga el motor frecuentemente puede que tenga una situaci n de bajo voltaje Tambi n se puede sospechar que existe bajo voltaje cuando 1 El motor no alcanza toda la potencia o velocidad 2 Otros dispositivos operados por motor no funcionan adecuadamente Muchos dispositivos con motor operando en el mismo circuito Z NOTA El motor de este compresor tiene un protector t rmico de sobrecarga Si el motor se llega a sobrecalentar el protector de sobrecarga apagar el motor Si esto sucede coloque el interrup tor ON OFF en la posici n OFF y permita que el motor se enfrie aproximadamente 5 minutos Vuelva a arrancar el compresor Si el compresor no arrancha espere otros 5 minutos antes de tratar de arrancarlo de nuevo Si esto no funciona inspeccione los fusibles de su unidad de suc ci n Si a n as la unidad no arranca llame inmediatamente a su proveedor de equipo m dico Informacion de seguridad o N ADVERTENCIA El equipo necesita operarse adecuadamente para evitar el da o f sico El uso inadecuado puede ocasionar lesiones personales y o da o al tejido Este producto no debe utilizarse a menos que el o
10. ERMITTED BY LAW SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU This warranty gives you specific legal rights and you may also have other rights which vary from state to state For Service Call Your Authorized Drive Medical Dealer 2 O x a lt m Lu 2 Lu a a gt 5 3 www drivemedical com indice ai 1 Informaci n de seguridad 14 2 Fuente de alimentaci n de CA 15 3 Sistema eleccion lar1 A A 5 Diagrama de partes importantes 17 A COOP OO a TO 7 C mo operar su bomba de succi n de uso pesado 18 8 Instrucciones para limpiar su unidad omomomommmmmmmmmm P 20 9 Manteniment O assaut el 10 Soluci n de problemas ss ss 21 1 Especificaciones clasificaciones 22 12 GA gol gud fc naa ZO A PRECAUCION La ley federal restringe este aparato para que se venda por un m dico o por orden de un m dico o cualquier otro profesional de la salud autorizado por la ley del estado en donde se ejerce la profesi n para utilizar u ordenar el uso de este aparato NOTA Verifique TODAS las partes para verificar que no existan da os durante el envio NO LO use si detecta da os por envio P ngase en contacto
11. USER S MANUAL MANUAL DEL USUARIO GUIDE DE LUTILISATEUR ITEM 18600 www drivemedical com index l Safety ntormatiO assess 2 2 AC PONET OUT arta 3 A per eter een 3 4 Re ne ee ee a er a 4 5 Illustration of Important Parts 5 dl et uan a a a ns 6 7 How to Operate Your Heavy Duty Suction Pump 6 7 8 Cleaning INSEUCTIGNS 5 48 ee 7 8 D PISE nit 8 9 10 Troubleshooting aries 9 11 Specifications Classifications 10 UL NV OP ONE immo 11 NM CAUTION Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device ZN NOTE Check ALL parts for shipping damage If shipping damage is noted DO NOT use Contact medi cal equipment provider for further instruction safety information 1 SAFETY INFORMATION When using electrical products especially when children are present basic safety precautions should always be followed Read all instructions before using Important information is highlighted by these terms N DANGER Urgent safety information for hazards that will cause serious injury or death N WARNING Important safety information for hazards that might cause serious injury ZN CAUTION Information for preventing damage to the product NOTE Information to which you should pay special attention read all user s manual
12. be en esta guia 3 Nunca opere este producto si a Tiene un cable o clavija el ctrica da ada b No est trabajando adecuadamente c Se ha caido o da ado d Se ha caido dentro del agua 4 Regrese el producto a un centro autorizado de servicio de equipo m dico Drive para exami narlo y repararlo 5 Mantenga el cable el ctrico alejado de superficies calientes 6 Nunca utilice el aparato si est mareado a o adormilado a Informacion de seguridad A ADVERTENCIAS ESPEC FICAS NO DESARME LA UNIDAD PARA REDUCIR EL RIESGO DE DESCARGA EL CTRICA O LE SIONES A PERSONAS SI SE DESARMA O REALIZAN REPARACIONES INCORRECTAMENTE SE PUEDE CREAR UNA DESCARGA EL CTRICA SOLO T CNICOS CALIFICADOS DEBER N REALIZAR REPARACIONES A LA UNIDAD DE SUCCI N ZA PELIGRO La bomba de succi n de uso pesado es un dispositivo de succi n a vacio dise ado para recolec tar fluidos no inflamables y solamente es para aplicaciones m dicas El uso inadecuado durante las aplicaciones m dicas puede resultar en lesiones o la muerte Para todas las aplicaciones m dicas 1 Toda succi n debe hacerse siguiendo estrictamente los procedimientos adecuados que han sido establecidos por un profesional m dico con licencia 2 Puede que algunos aditamentos o accesorios no se ajusten a la tuber a proporcionada Se de ben de verificar todos los aditamentos o accesorios antes de su uso para asegurar que se ajusten adecuadamente 2 FUENTE DE ALIMENTACI N DE
13. before using save user s manual ZA DANGER To reduce the risk of electrocution 1 Do not use while bathing 2 Do not place or store product where it can fall or be pulled into a tub or sink 3 Do not place in or drop into water or other liquid 4 Do not reach for a product that has fallen into water Unplug immediately ZN WARNING To reduce the risk of burns electrocution fire or injury to persons Close supervision is necessary when this product is used by on or near children or invalids Use this product only for its intended use as described in this guide Never operate this product if It has a damaged power cord or plug It is not working properly It has been dropped or damaged It has been dropped into water Return the product to an authorized Drive medical equipment service center for examination and repair Keep the power cord away from heated surfaces Ran TANN g 6 Never use while drowsy or asleep safety information 6 A SPECIFIC WARNINGS TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS DO NOT DISASSEMBLE THIS UNIT DISASSEMBLY OR ATTEMPTED REPAIRS IF ACCOMPLISHED INCORRECTLY CAN CREATE ELECTRICAL SHOCK HAZARD ONLY QUALIFIED TECHNICIANS SHOULD PERFORM SERVICING OF THIS SUCTION UNIT Z DANGER The Heavy Duty Suction Pump is a vacuum suction device designed for the collection of nonflam mable fluid materials in medical applications only Improper use during medical applications can cause injur
14. collection bottle still in the holder remove the collection bottle lid The bottle can now be taken out of the holder to be emptied N NOTE Collection bottle should be emptied after each use 3 Collection bottle should be thoroughly cleaned after each use by one of the following three methods a Wash in a hot water dishwashing detergent solution and rinse with clean hot tap water Then wash in one part vinegar to three parts hot water solution Rinse with hot tap water and air dry b Wash with rubbing alcohol and air dry c Wash with a commercial bacterial germicidal disinfectant follow disinfectant manufacturer s recommended instructions and dilution rates carefully cleaning amp maintenance o Clean Suction Unit and Collection Bottle Lid 1 Disconnect the suction unit from all external power sources 2 Wipe the suction unit housing and collection bottle lid with a clean cloth and any commer cial bacterial germicidal disinfectant ZA CAUTION Do not submerge in water as this will result in severe damage to the vacuum pump Clean Tubing 1 Disconnect the tubing from the unit 2 Tubing should be rinsed thoroughly after every use by running hot tap water through it followed by a solution of one part vinegar to three parts hot water 3 Rinse with hot tap water and air dry A Keep the outer surface of the tubing clean by wiping with a clean damp cloth Z WARNING The waste in collection bottle may cause r
15. con su proveedor de equipo m dico para recibir indicaciones adicionales Informacion de seguridad 1 INFORMACION DE SEGURIDAD Cuando se utilizan productos el ctricos y especialmente cuando los ni os est n presentes es im portante seguir precauciones b sicas de seguridad Lea todas las instrucciones antes de su uso La informaci n importante se resalta con estos t rminos PELIGRO Informaci n de seguridad urgente sobre riesgos que pueden ocasionar lesiones serias o la muerte ADVERTENCIA Importante informaci n de seguridad para peligros que pueden ocasionar lesiones serias ZN PRECAUCI N Informaci n para evitar da os al producto NOTA Informaci n a la cual debe poner atenci n especial lea todo el manual del usuario antes de usar la unidad guarde este manual del usuario ZN PELIGRO Para reducir el riesgo de electrocuci n 1 No lo use mientras se est ba ando 2 No coloque o almacene el producto en un lugar en donde pueda caerse o jalarse y caer dentro de una tina o lavabo 3 No lo coloque o tire dentro de agua o cualquier otro l quido 4 No trate de sacar un producto que ha ca do dentro del agua Descon ctelo inmediatamente A ADVERTENCIA Para reducir el riesgo de quemaduras electrocuci n incendio o lesiones a personas 1 El producto debe ser supervisado de cerca cuando sea utilizado por con o cerca de ni os o personas discapacitadas 2 Utilice este producto s lo para el uso que se descri
16. cteur de 800 ml et il a t con u pour un fonctionnement fiable et pratique Caract ristiques Nouveau filtre antibact rien qui aide pr venir les cas de contamination R gulateur d aspiration de haute qualit et manom tre antivibration Lubrification permanente sans huile R cipient collecteur avec protection contre les d bordements Performance sup rieure et grande fiabilit pour un usage continu e Entretien et nettoyage facile Le respect des proc dures d utilisation et d entretien d crites dans ce guide prolongera la dur e de vie utile de cet appareil Consultez le diagramme la page 6 ZN NOTA Cet appareil est conforme aux normes nationales concernant les champs lectromagn tiques tel que d crit dans la d claration de conformit jointe diagramme des principales pieces 0 Article No 18600 1 Manometre 2 Bouton d ajustement de l aspiration 3 Filtre antibact rien 4 Porte cordon 5 Base 6 Contenant collecteur de 800 cc 7 Tube d aspiration 8 Couvercle 9 Tube de liaison 10 Interrupteur 11 Cordon d alimentation 12 Fusible Installation et fonctionnement 1 Branchez n importe quel des deux extr mit s du tube No 9 sur le dessus du contenant collec teur et branchez l autre extr mit au filtre antibact rien 2 Le tube de pr l vement doit tre branch au contenant collecteur la prise tiquet e Patient Assurez vous que tous le
17. den ocasionar infec ciones respiratorias Coloque la botella de recolecci n tuber a y filtro a desechar dentro de un contenedor de desecho etiquetado como desecho m dico soluci n de problemas Su bomba de succi n de uso pesado no trae refacciones Si usted piensa que su unidad no est trabajando adecuadamente ANTES DE REGRESARLA AL PROVEEDOR DE EQUIPO MEDICO EN DONDE LO COMPRO tome unos cuantos minutos para verificar las posibles causas PROBLEMA ACCI N La unidad no enciende 1 Verifique la fuente de alimentaci n y la conexi n 2 Aseg rese que la toma de la pared tiene corriente 3 Verifique que el cable de alimentaci n no est da ado El motor arranca pero no produce vac o 1 Verifique la conexi n de la tuber a 2 Verifique que no existan fugas o que la tuber a no est retorcida 3 Aseg rese que el flotador de cierre no est activado 4 Verifique que la botella no tenga fugas ni grietas Bajo vacio 1 Utilice la perilla de ajuste de vac o para aumentarlo Nivel de vacio 2 Verifique que no existan fugas en el sistema 3 Ajuste la perilla de ajuste de vacio y liberaci n especificaciones clasificaciones 0 Dimensiones Peso Maximo vac o Rango de flujo Nivel de ruido Requisitos el ctricos Consumo de energ a Tama o de poro del filtro bacteriano Capacidad de botella de recolecci n Temperatura de operaci n Humedad de operaci n Presi n atmosf rica de operaci n Temperatura de almacenamiento
18. e cada uso inspeccione la tuber a de succi n y la botella de recolecci n para verificar que no tenga fugas grietas etc PELIGRO Peligro de descarga el ctrica No intente abrir o retirar el gabinete de succi n Si necesita dar mantenimiento a su unidad ll vela a un centro de servicio autorizado El abrir o alterar la unidad anular la garantia Cambio del filtro bacteriano 1 El filtro bacteriano deber reemplazarse como sea necesario Si se presenta un sobre flujo reemplace el filtro inmediatamente 2 Para quitar el filtro descon ctelo de la tuber a conectada a la v lvula de ajuste de presi n y a la tuber a conectada al montaje de la tapa de la botella de recolecci n 3 Coloque un filtro bacteriano nuevo Drive y con ctelo a las dos tuberias anteriores Puede comprar filtros adicionales con un distribuidor autorizado mantenimiento N NOTA Solamente use filtros Drive No sustituya ning n otro tipo de material para el filtro bacteriano Las sustituciones inadecuadas pueden conducir a la contaminaci n o un pobre rendimiento Cambio de fusibles 1 Utilice s lo el mismo tipo de fusible para reemplazar un fusible roto 2 Especificaciones del fusible Fusible miniatura de vidrio 5x20mm Fusible de acci n r pida F2A 250V Z ADVERTENCIA Cuando esta unidad o accesorios alcanzan el final de su vida til que depende de las condi ciones de uso los residuos en la botella de recolecci n tuber a y filtro pue
19. eading Vacuum Gauge Handle Vacuum Adjust Knob set up amp operation O 4 Place the patient tubing to the appropriate position of patient and start to suck sputum 5 When the sputum reaches the safe full level of collection bottle 800 cc the suctioning will stop sucking automatically float shut off 6 Switch the power switch to O position off shut off the suction motor 7 Remove the sputum from collection bottle after the motor stops turning completely Please refer to the section CLEAN INSTRUCTIONS on page 9 for the directions of how to clean the collection bottle 8 Turn on the unit and start to run the suction unit again N NOTE 1 If the unit sustains a severe drop validity of the gauge must be checked Inspect if the float shut off is still functioning properly when the liquid in the collection bottle reaches the safe full level 2 Always transport unit with vacuum adjust knob rotated fully clockwise in case unit is dropped Z CAUTION 1 When automatic float shut off is activated contents of the collection bottles should be emp tied Further suctioning could cause damage to the vacuum pump 2 Should fluid be aspirated back into the unit send your suction to an authorized service center for a detailed inspection as the vacuum pump may have been damaged cleaning Clean Collection Bottle 1 Turn off the suction unit and allow vacuum to drop then disconnect AC power source 2 With the
20. ecessary to avoid physical harm Improper use can cause personal injury and or tissue damage This product should not be used unless the operator has been instructed by a physician or other qualified health care professional 1 Familiarize yourself with this unit 2 Place unit on table and push down hard so that suction feet hold unit firmly in place 3 Before plugging power cord into electrical outlet check if the ON OFF switch is in the OFF position ZN NOTE Before attempting to start a cold unit let the unit reach room temperature in a heated area introduction Your Heavy Duty Suction Pump is a professional medical suctioning device that produces a maxi mum vacuum of 560 mmHg The unit is equipped with an 800 ml collection bottle and has been designed for convenient and reliable usages Features New anti bacteria filter design helps prevent contamination High quality vacuum regulator and anti vibration vacuum gauge setting Oil less permanent lubrication Collection bottle with overflow protection Superior performance and high reliability for continuous operation design Easy carry and easy cleaning Following the recommended operating and maintenance procedures outlined in this user s manual will maximize the life of this product Refer to the diagrams on page 6 AX NOTE This unit complies with electromagnetic compatibility standards as defined in the attached declaration of conformity illustrati
21. espiratory infection which must be handled according to medical waste disposing regulation Operator must wear gloves and medical class mask be fore cleaning the collection bottle tubing and handle the wasting unit and or accessories MAINTENANCE Inspect suction tubing and collection bottle for leaks cracks etc before each use Z DANGER Electric shock hazard Do not attempt to open or remove the suction cabinet If a service is required return your suction to an authorized service center Opening or tampering with the unit will void warranty Bacteria Filter Change 1 Bacteria filter should be replaced as needed If overflow occurs change the filter immediately 2 Remove filter by disconnecting it from tubing connected to pressure adjusting valve and tubing connected to collection bottle lid assembly 3 Replace with a new Drive bacteria filter and connect to above two tubing Additional filters can be purchased from an authorized dealer maintenance Z NOTE Use only Drive filters Do not substitute any other material for this bacteria filter Improper substitution may lead to contamination or poor performance Fuse Change 1 Use only the same type of fuse to replace the broken fuse 2 Fuse specification Miniature Glass Fuse 5x20mm Fast Blow Quick Acting F2A 250V ZN WARNING When this unit or accessories reach the end of their useful lives depends on using conditions residues in collection bottle tubing and
22. filter may cause respiratory infection Dump the wasting collection bottle tubing and filter into a specific waste bin labeled with medical waste troubleshooting Your Heavy Duty Suction Pump contains no user serviceable parts If you believe your unit is not working properly BEFORE YOU RETURN IT TO THE MEDICAL EQUIPMENT PROVIDER WHERE YOU PURCHASED IT please take a few moments to check for these possible causes PROBLEM ACTION Unit does not turn on 1 Check power source and connection 2 Ensure that the wall outlet is live 3 Check power cord is not damage Motor runs no vacuum 1 Verify tubing connection security 2 Check for leaks or tubing kinks 3 Ensure that float shut off is not activated 4 Check for bottle leaks and cracks Low Vacuum 1 Use vacuum adjust knob to increase vacuum level 2 Check system for leaks 3 Adjust vacuum adjust knob and release specifications classifications Dimensions Weight Maximum Vacuum Flow Range Sound Level Electrical Requirements Power Consumption Bacteria Filter pore size Collection Bottle Capacity Operating Temperture Operating Humidity Operating Atmospheric Pressure Storage Temperture Storage Humidity Storage Atmospheric Pressure Fuse Specification Equipment Classifications L 375 x W 175 x H 250 mm 14 8 x 6 8 x 9 8 in 5 5 kg 12 1 lb 560 3 mm Hg gt 40 LPM lt 58 dBA AC 115 V 60Hz 70 watts 0 45 microns 800 ml cc 32 104
23. is de mani re inad quate pendant la p riode de couverture de la garantie Assurez vous que le d faut de fonctionnement n est pas caus par un nettoyage inad quat ou un manquement suivre les instructions Si une r paration s av re n cessaire communiquez avec votre revendeur d quipement m dical NOTA La garantie ne pr voit pas le pr t d un appareil de remplacement ni la compensation financi re pour les frais de location d un appareil de remplacement pendant que l appareil garanti est en r paration ni les co ts de main d uvre associ s la r paration ou au remplacement de la des pi ce s d fectueuse s DRIVE NE CONC DE AUCUNE AUTRE GARANTIE EXPRESSE LES GARANTIES IMPLICITES INCLUANT LES GARANTIES DE QUALITE MARCHANDE ET DE CONVENANCE A UN USAGE PARTICULIER SONT LIMIT ES LA P RIODE DE COUVERTURE DE LA GARANTIE LIMIT E EXPRESSE ET DANS LES LIMITES IMPOS ES PAR LES LOIS APPLICABLES TOUTES LES GARANTIES IMPLICITES SONT EXCLUES CETTE GARANTIE REPR SENTE VOTRE UNIQUE VOIE DE RECOURS ET LA RESPONSABILIT DE DRIVE CONCERNANT TOUT DOMMAGE INDIRECT OU ACCESSOIRE COUVERT PAR N IMPORTE LAQUELLE OU TOUTES LES GARANTIES SONT EXCLUES DANS LES LIMITES IMPOS ES PAR LA LOI CERTAINS TATS NE PERMETTENT PAS LA LIMITATION DE LA DUR E LIMIT E D UNE GARANTIE IMPLICITE OU LA LIMITATION OU L EXCLUSION DES DOMMAGES DIRECTS OU INDIRECTS IL EST POSSIBLE QUE LES EXCLUSIONS ET LIMITATIONS EXPRIM ES ICI NE S APPLIQUENT P
24. la pr sence de fuites 3 Ajustez le bouton de contr le de l aspiration et le d tendeur sp cifications classification Dimensions Poids Aspiration maximale D bit Niveau acoustique Alimentation lectrique Consommation d lectricit Dimension des pores du filtre antibact rien Capacit du contenant collecteur Temperature d utilisation Humidit ambiante Pression barom trique ambiante Temp rature d entreposage Humidit au site d entreposage Pression barom trique au site d entreposage Caract ristiques du fusible Classification de l quipement L 375 x L 175 x H 250 mm 14 8 x 6 8 x 9 8 po 5 5 kg 12 1 lb 560 3 mm Hg gt 40 LPM lt 58 dBA CA 115 V 60 Hz 70 watts 0 45 microns 800 ml cc 32 104 F 0 40 C 95 HR 10 2 15 4 psi 70 106 kpa 14 158 F 10 70 C O 95 7 3 15 4 psi 50 106 kpa Fusible miniature de verre 5 x 20 mm action rapide F2A 250 V Classe pour la protection contre les chocs lectriques garantie Garantie Limit e de Deux Ans Le compresseur de la pompe aspiratrice DRIVE est garanti contre tout d faut mat riel ou de fabrication pour une p riode de deux ans compter de la date d achat et les accessoires sont garantis pour une p riode de six mois Toute pi ce d fectueuse sera r par e ou remplac e la discr tion de DRIVE la condition que l appareil n ait pas t alt r ou util
25. lacement du fusible 1 Ne remplacez le fusible que par un fusible neuf du m me type 2 Caract ristiques du fusible fusible miniature en verre 5 x 20 mm action rapide F2A 250 V N AVERTISSEMENT Lorsque cet appareil ou ses accessoires atteignent la fin de leur vie utile varie en fonction de l utilisation les r sidus dans le contenant collecteur les tubes et le filtre peuvent causer des in fections respiratoires Disposez du contenant collecteur des tubes et du filtre dans un contenant pr vu pour les d chets m dicaux d pannage Votre pompe aspiratrice robuste ne contient aucune pi ce dont l entretien peut tre fait par l utilisateur Si vous croyez que l appareil ne fonctionne pas correctement v rifiez les points suiv ants AVANT DE LE RAPPORTER CHEZ VOTRE FOURNISSEUR D QUIPEMENT M DICAL PROBL ME L appareil ne d marre pas Le moteur fonctionne aucune succion Aspiration faible SOLUTION 1 V rifiez la source d alimentation lectrique et les branchements 2 Assurez vous que la prise de courant est aliment e 3 V rifiez le cordon d alimentation 1 V rifiez tous les branchements des tubes 2 V rifiez s il y a des fuites ou si un tube est coinc 3 Assurez vous que l interrupteur flotteur n est pas d clench 4 V rifiez la pr sence de fuites ou de craquelures au niveau du contenant 1 Augmentez l aspiration l aide du bouton de contr le 2 V rifiez
26. n alcohol para frotar y secar al aire c Lavar con un desinfectante comercial bacteriano germicida siga cuidadosamente las instruc ciones recomendadas por el fabricante y las proporciones de diluci n Impieza amp mantenimiento Limpie la unidad de succi n y la tapa de la botella de recolecci n 1 Desconecte la unidad de succi n de todas las fuentes de alimentaci n externas 2 Limpie la cubierta de la unidad de succi n y la tapa de la botella de recolecci n con un trapo limpio y cualquier desinfectante comercial bacteriano germicida ZN PRECAUCI N No sumerja la unidad en agua ya que esto resultar en un da o severo a la bomba de vac o Limpiando la tuber a L Desconecte la tuberia de la unidad 2 La tuberia debe de enjuagarse minuciosamente despu s de cada uso dejando que agua potable caliente fluya a trav s de sta y despu s con una soluci n de una parte de vinagre con tres partes de agua caliente 3 Enju guela con agua potable caliente y d jela secar al aire 4 Limpie la superficie externa de la tuberia con un trapo h medo ZA ADVERTENCIA Los residuos dentro de la botella de recolecci n pueden ocasionar infecciones respiratorias por lo tanto deben manejarse de acuerdo a las normas de manejo de desechos m dicos El operador debe utilizar guantes y una mascarilla de uso m dico antes de limpiar la botella de recolecci n tuberia y manipular la unidad y o los accesorios MANTENIMIENTO Antes d
27. ncendido 3 Ajuste el nivel de vac o entre O a 560 mm Hg girando la perilla de ajuste de vac o en sentido de las manecillas del reloj para aumentar el vac o y en contra de las manecillas para disminuir el vacio Observe el man metro de vac o mientras configura la unidad al nivel de vac o deseado Para leer con exactitud el man metro bloquee el extremo de la manguera del paciente o tape la botella de recolecci n y permita que el man metro logre una lectura de vac o estable Man metro de vacio Agarrader Perilla de ajuste de vac o configuracion amp operacion 4 Coloque la tuber a del paciente en la posici n adecuada del paciente y empiece a succionar esputo 5 Cuando el esputo alcanza el nivel seguro de llenado en la botella de recolecci n 800cc la suc ci n se apagar autom ticamente el flotador la apaga 6 Coloque el interruptor en la posici n O apagado se apaga el motor de succi n 7 Elimine el esputo de la botella de recolecci n despu s de que el motor se haya parado comple tamente Vea por favor la secci n INSTRUCCIONES PARA LIMPIAR SU UNIDAD de la p gina 9 sobre como limpiar su botella de recolecci n 8 Encienda la unidad y empiece la succi n de nuevo ZN NOTA 1 Sila unidad se somete a una caida severa entonces la validez del man metro tendr que ser verificada Inspeccione si el flotador de cierre sigue funcionando adecuadamente cuando el liquido dentro de la
28. on of important parts_ 9 Item 18600 Vacuum Gauge Vacuum Adjust Knob Bacteria Filter Cord Caddy Base 800cc Collection Bottle Patient Tubing Cover Connection Tubing 10 Power Switch 1 Power Cord 12 Fuse ONDUAN set up amp operation o 1 Connect either end of the connecting tubing item 9 to the top of collection bottle connector then connect the other end to the bacteria filter 2 The patient tubing should be connected to collection bottle at the outlet labeled patient Please assure that all connections are secure and without leaks before using 7 HOW TO OPERATE YOUR HEAVY DUTY SUCTION PUMP 1 Before use check the specification label on the side of the suction unit to ensure that the volt age and current indicated on the unit correspond with the voltage and current available Make sure the power switch located on the side of the unit is in the Off position before connecting the unit to a power source 2 Switch the power switch to R position on the unit start running 1 Off position 2 On position off position 3 Adjust the vacuum level from O to 560 mm Hg by turning the vacuum adjust knob clockwise to increase vacuum and counter clockwise to decrease vacuum Referring to the vacuum gauge while setting the desired level of vacuum To accurately read the gauge block the patient end of the hose or cap off the collection bottle and allow the gauge to reach a stable vacuum r
29. perador haya sido instruido por parte de un m dico u otro personal de cuidado de salud cali ficado 1 Usted debe de familiarizarse con esta unidad 2 Coloque la unidad sobre una mesa y presione fuerte hacia abajo para que las patas de succi n de la unidad se sujeten firmemente en su lugar 3 Antes de conectar el cable dentro de una toma el ctrica verifique que el interruptor ON OFF est en la posici n OFF Z NOTA Si la unidad est en un rea con calefacci n deje que la unidad alcance la temperatura ambien tal antes de encenderla introducci n Su bomba de succi n de uso pesado es un dispositivo profesional m dico de succi n que produce un vac o m ximo de 560 mmHg La unidad est equipada con una botella de recolecci n de 800 ml y est dise ada para varios y c modos usos Caracter sticas Nuevo filtro anti bacteriano dise ado para ayudar a evitar la contaminaci n Regulador de vacio de alta calidad y configuraci n de man metro de vac o contra vibraciones Lubricaci n permanente no necesita aceite Botella de recolecci n con protecci n de rebosamiento Dise o de desempe o superior y alta confiabilidad para una operaci n continua F cil de transportar y f cil de limpiar El seguir los procedimientos recomendados de operaci n y mantenimiento descritos en este manual del usuario maximizar la vida de su producto Vea los diagramas en la p gina 6 Z NOTA Esta unidad cumple con los estandare
30. r teindre l appareil 7 Retirez les s cr tions du contenant collecteur apr s que le moteur ait compl tement cess de tourner consultez la section NETOYAGE la page 9 au sujet de l entretien du contenant collect eur 8 Remettez l appareil sous tension et reprenez l op ration ZN NOTA Si vous avez chapp l appareil ou qu il a subi un choc important l exactitude du manom tre doit tre v rifi e V rifiez le fonctionnement de l interrupteur flotteur lorsque le niveau maximal est atteint dans le contenant collecteur Avant de transporter l appareil tournez toujours le bouton de r glage de l aspiration compl te ment dans le sens horaire ce qui est pr f rable en cas de chute Z MISE EN GARDE 1 Lorsque l interrupteur flotteur se d clenche videz le contenant collecteur Si vous persistez utiliser l appareil au del de cette limite vous pourriez endommager la pompe 2 Si un liquide est aspir dans l appareil au del du contenant collecteur envoyez l appareil dans un centre de service autoris pour qu il soit examin avec soin car il est possible que la pompe soit endommag e nettoyage Nettoyer le contenant collecteur 1 Mettez la pompe hors tension et attendez que l aspiration cesse compl tement D branchez l alimentation lectrique 2 Laissez le contenant collecteur en place et retirez son couvercle Le contenant peut mainte nant tre retir et vid Z NOTA Le contenant collecteu
31. r doit tre nettoy apres chaque usage 3 Le contenant collecteur doit tre soigneusement nettoy apres chaque usage d une des mani res suivantes a Lavez l aide d une solution d tergente pour eau chaude lave vaisselle et rincez l eau chaude et propre du robinet Lavez ensuite l aide d une solution faite d une partie de vinaigre et de trois parties d eau chaude Rincez l eau chaude du robinet et laissez s cher l air b Lavez l aide d alcool friction et laissez s cher l air c Lavez l aide d un d sinfectant commercial antibact rien germicide Suivez les instructions et respectez les taux de dilutions recommand s par le fabricant du produit nettoyage et entretien 8 Nettoyez la pompe et le couvercle du contenant collecteur 1 D branchez la pompe de l alimentation lectrique 2 Essuyez le bo tier de la pompe et le couvercle du contenant collecteur l aide d un chiffon propre et d un d sinfectant commercial antibact rien germicide ZN MISE EN GARDE N immergez pas l appareil dans l eau car ceci endommagerait la pompe de fa on irr m diable Nettoyez le tube 1 D branchez le tube de l appareil 2 Le tube doit tre soigneusement rinc apr s chaque usage en y faisant couler de l eau chaude du robinet puis une solution faite d une partie de vinaigre pour trois parties d eau chaude 3 Rincez l eau chaude du robinet et laissez s cher l air 4 Nettoye
32. rridos en reparar o reemplazar la s parte s defectuosa s NO EXISTE NINGUNA OTRA GARANTIA EXPLICITA LAS GARANTIAS IMPLICITAS INCLUYENDO AQUELLAS DE COMERCIABILIDAD Y APTITUD PARA UN PROPOSITO EN PARTICULAR SE LIMITAN A LA DURACION DE LA GARANTIA EXPLICITA Y HASTA EL GRADO PERMITIDO POR LA LEY SE EXCLUYEN CUALQUIER Y TODAS LAS GARANTIAS IMPLICITAS ESTE ES EL RECURSO Y RESPONSABILIDAD EXCLUSIVA PARA DA OS PUNITIVOS E INCIDENTALES BAJO CUALQUIER Y TODA GARANT A Y SE EXCLUYEN HASTA EL GRADO DE EXCLUSI N PERMITIDO POR LA LEY ALGUNOS ESTADOS NO PERMITE LIMITES SOBRE QUE TANTO TIEMPO PUEDE DURAR UNA GARANT A IMPL CITA O EL LIMITE O EXCLUSI N DE DA OS PUNITIVOS O INCIDENTALES AS QUE PUEDE QUE EL LIMITE O EXCLUSI N ANTERIOR NO SE APLIQUE A SU CASO Esta garant a le proporciona derechos legales especificos usted puede tener otros derechos que var an de estado a estado Para servicio llame a su distribuidor autorizado Drive Medical www drivemedical com 2 O s lt gt a Lu 2 LU E a z 3 5 gt table des mati res 1 Renseignement concernant la s curit 25 2 Alimentation lectrique 26 3 lectricit nr 26 27 A OO olaaa 27 5 Diagramme des principales pi ces 28 IST Oricon 29 7 Utilisation votre pompe aspiratrice robuste 29 8 Instructions de nettoyage 30 31 ENTE Ninos 32 TOs DEPARA Suera 32 1 Sp cifications classification 33 pac a A 34 ZA MISE EN GARDE
33. s branchements sont solides et qu il n y a pas de fuite avant d utiliser l appareil 7 UTILISATION DE VOTRE POMPE ASPIRATRICE ROBUSTE 1 Avant l utilisation v rifiez la plaque signal tique appos e sur le c t de l appareil pour vous assurer que la tension et le courant mentionn s sur la plaque correspondent au type d alimentation lectrique dont vous disposez Assurez vous que l interrupteur est la position ARR T O ou OFF avant de brancher l appareil 2 Mettez l interrupteur la position MARCHE I ou ON pour le mettre en marche 1 Positon ARR T O ou OFF 2 Position MARCHE I ou ON 3 Ajustez le niveau de l aspiration entre O et 560 mm Hg l aide du bouton d ajustement de l aspiration sens horaire pour augmenter l aspiration antihoraire pour la diminuer Observez le manom tre pendant que vous proc dez l ajustement Pour une lecture pr cise bloquez l extr mit du tube de pr l vement ou bouchez la prise du contenant collecteur et attendez que le manom tre donne une lecture stable Manom tre vide Poign e Ss Nas SD A SM Bouton d ajustement de D l aspiration installation et fonctionnement 4 Positionnez le tube ad quatement sur le patient et aspirez les s cr tions 5 Lorsque les s cr tions atteignent le niveau maximal du contenant collecteur 800 cc l aspiration cessera automatiquement interrupteur flotteur 6 Mettez l appareil hors tension O ou OFF pou
34. s de compatibilidad electromagn ticos como se define el la declaraci n de conformidad anexada diagramas de partes importantes Articulo 18600 1 Man metro de vacio 2 Perilla de ajuste de vacio 3 Filtro bacteriano 4 Bandeja para el cable 5 Base 6 Botella de recolecci n de 80Occ 7 Tuber a para el paciente 8 Cubierta 9 Tuber a de conexi n 10 Interruptor 11 Cable de energ a 12 Fusible configuraci n amp operaci n e 1 Conecte cualquier extremo de la tuber a de conexi n art culo 9 al conector de la parte su perior de la botella de recolecci n luego conecte el otro extremo al filtro bacteriano 2 La tuber a del paciente debe ser conectada a la botella de recolecci n en la tuber a de salida que tiene la etiqueta paciente Aseg rese por favor que todas las conexiones est n seguras y que no existan fugas antes de utilizarse 7 C MO OPERAR SU BOMBA DE SUCCI N DE USO PESADO 1 Antes de usarse verifique que la informaci n de voltaje y corriente incluida en la etiqueta de especificaci n ubicada en el lado de la unidad de succi n coincida con el voltaje y corriente disponible Aseg rese que el interruptor de energ a ubicado en la parte lateral de la unidad est en la posici n Off antes de conectar la unidad a una fuente de alimentaci n 2 Cambien el interruptor a la posici n I encendido la unidad empieza a funcionar 1 Posici n de apagado 2 Posici n de e
35. y or death For all medical applications 1 All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority 2 Some attachments or accessories may not fit the tubing supplied All attachments or accesso ries should be checked prior to use to assure proper fit 2 AC POWER SOURCE Z CAUTION Item 18600 is used with a power supply allowing operation on AC voltage 115 VAC 60 Hz However the correct power source must be used to connect to adaptable wall power 3 ELECTRICAL Compressor If the overload protector shuts off the motor frequently you may have a low voltage situation Low voltage can also be suspected when 1 The motor does not get up to full power or speed 2 Other motor operated appliances fail to operate properly Too many motor operated appli ances on same circuit Z NOTE The motor of this compressor has a thermal overload protector If the motor overheats the over load protector will shut off the motor If this occurs turn the ON OFF switch to the OFF position and allow the motor to cool approximately 5 minutes Restart compressor If the compressor fails to start wait an additional 5 minutes before attempting to restart If this fails inspect the fuses on your suction unit If the unit still does not restart call your medical equipment provider immediately safety information O ZA WARNING Proper operation of this product is n
36. z la surface ext rieure du tube l aide d un chiffon propre et humide Z AVERTISSEMENT Les s cr tions dans le contenant collecteur peuvent causer des infections respiratoires et doivent tre trait es comme des d chets m dicaux L op rateur doit porter des gants et un masque m dical pour nettoyer le contenant le tube et pour manipuler le contenant collecteur et ou les accessoires ENTRETIEN Avant chaque usage v rifiez que le tube et le contenant collecteur sont exempts de fuites fendillements etc ZN DANGER Risques d lectrocution Ne tentez pas d ouvrir ou de retirer le dispositif de succion Si l appareil n cessite un entretien rapportez le dans un centre de service autoris L ouverture ou la modification de l appareil annule la garantie Remplacement du filtre antibact rien 1 Le filtre antibact rien doit tre remplac au besoin Changez le filtre imm diatement lor sque survient un d bordement 2 Retirez le filtre en le d branchant des tubes qui relient la vanne d ajustement de la pres sion et au couvercle du contenant collecteur 3 Installez un nouveau filtre antibact rien Drive et rebranchez les deux tubes Vous pouvez vous procurer des filtres de rechange chez un revendeur autoris entretien ZA NOTA N utilisez que des filtres Drive N utilisez aucun autre mat riau en lieu et place du filtre au risque de cr er un site de contamination ou de nuire l efficacit du syst me Remp