MANUAL DEL USUARIO

image

Contents

1. Padang Lime Padauk African Loliondo Panga Panga Mahogany African Persimmon Mahogany West Indian Pillarwood Makore Pine American Long Leaf Mansonia Pine American Pitch Maple Pacific Pine Bunya Maple Queensland Pine Caribbean Pitch Maple Rock Pine Coriscan Maple Sugar Pine Hoop Matai Pine Huon Meranti Red Light or Dark Pine Kauri Meranti White Pine Lodgepole Merbau Pine Maritime Missanda Pine New Zealand White Muhuhi Pine Nicaraguan Pitch Muninga Pine Parana Musine Pine Ponderosa Musizi Pine Radiata Myrtle Tasmanian Pine Scots Niangon Pine Sugar Oak American Red Pine Yellow Oak American White Poplar Black Oak European ejeje Jw je j Injo Ww DN DN IN BE Jeje INS RPN INS DS o JVA ju 0 jwe UI CO ajerjea jo ju Pterygota African Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Pyinkado Bb PR P PRJO0O R R W IN W IN IN PR P N 0 0 W N WII e I nje NO DN INS IAIA JJe twili int sa de cv Instrumentos de Medici n Industrial Material Mad
2. twili lo de cv Instrumentos de Medici n Industrial E te METER Medidor de Humedad LT MS7000HA Simi ITe sa de cv Instrumentos de Medici n Industrial Tabla de Contenidos 1 Caracter sticas 2 Especificaciones 3 Descripci n del panel frontal 3 1 Enchufe de entrada de la sonda 3 2 Pantalla 3 3 Bot n de encendido apagado 3 4 Registro bot n de memoria 3 5 Bot n de memoria memoria 3 6 Bot n Temp Ajustar compensaci n Manual 3 7 Bot n de Retenci n de Datos 3 8 Bot n para seleccionar material 9 grupos de cada tipo de material 3 9 Bot n de Calibraci n 3 10 Tapa Compartimiento de la Bater a 3 11 Sonda de Mango 3 12 Electrodos tipo clavo 4 Tabla de los 9 grupos de cada material madera 4 1 Clasificaci n por orden alfab tico a z tabla 1 4 2 Clasificaci n por grupos de los 9 tipos de materiales 5 Procedimiento de medici n 5 1 Medici n seleccionando el grupo de material 5 2 Medici n por m todo de referencia 5 3 Temp Ajuste de compensaci n 6 Calibraci n 7 Mantenimiento 7 1 Reemplazo de la bater a 7 2 Reemplazo de los electrodos tipo clavo 1 Caracter sticas e Mide la cantidad de humedad en el rango de 9 hasta al 30 e 9tipos de materiales en memoria cuenta con calibraci n para cerca de 150 especies de madera e Circuito de calibraci n LSI incorporado e Ajuste manual de compensaci n de temperatura desde 02 a 50 C e El circuito
3. e Gum Southern e Hyedunani e lronbank e Mahogany West Indian e Makore e Mansonia e Maple Queensland e Meranti Red Light or Dark e Meranti White e Merbau e Okwen e Olive E African e Pine Bunya Myrtle Tasmanian Oak American Red Oak American White Oak European Oak Japanese Padang Panga panga Pine Lodgepole Pine Radiata Pine Scots Pine Yellow Poplar Black Pterygota African Redwood Baltic European Rosewood Indian Sterculia Brown Tallowwood Walnut American Pine Huon Pine Maritime Pine New Zealand White Pine Parana Redwood Californian Walnut New Guinea Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Instrumentos de Medici n Industrial e Ayan e Bech European e Blackbutt e Camphorwood E African e Cedar Western Red e Chestnut e Danta e Greenheart e Hemlock Western e Jarrah e Jelutong e Larch European e Larch Japanese e Loliondo e Missanda e Niangon e Oak Tasmanian e Pine American Long Leaf e Pine American Pitch e Pine Caribbean Pitch Material Grupo 4 e Abura e Afzelia e Binvang e Birch Yellow e Bisselon Elm English e Elm Rock e Elm White Material Grupo 5 e Baguacu Brazilian e Bitterwood e Cordia American light e Erimado e Hickory e Iro
4. White Bange Wanga Erimado Basswood Fir Douglas Bech European Fir Grand Berlina Fir Noble Binvang Gegu nohor Birch European Greenheart Birch Yellow Guarea Black Bisselon Guarea White Bitterwood Gum American Red Blackbutt Gum Saligna Bosquiea Gum Southern Boxwood Maracaibo Gum Spotted Cahoma Gurjun Camphorwood E African Hemlock Western Canarium African Hickory Cedar West indian Hyedunani Cedar Western Red jo nNn w er R R 0 un a pajo ai nNnw0 iD er Re UIJw R RIiN O O B NOD r NS Iroko Ironbank N U N UI W er rP N N FP N OoO Iw INIO IeINIVU AIARIAINIw JeIIl O W Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Instrumentos de Medici n Industrial Material Madera Grupo Jarrah Material Madera Grupo Jelutong Oak Japanese Kapur Oak Tasmanian Karri Oak Turkey Kauri New Zealand Obeche Kauri Queensland Odoko Keruing Okwen Kuroka Olive E African Larch European Olivillo Larch Japanese Opepe Larch Western
5. a sonda gt Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Simi __ sa de cv Instrumentos de Medici n Industrial 5 1 Medici n seleccionando el grupo de material 1 Encienda el medidor utilizando el bot n de Encendido Apagado Fig 3 3 1 quitar la protecci n de hule 3 13 Fig 1 lejos de los electrodos tipo clavo 3 12 Fig 1 2 Seleccione el grupo de material requerido mediante el bot n de selecci n de material 3 8 Fig 1 Con referencia a 4 1 tabla 1 seleccione un material de grupo 1 9 MATERIAL Para Chipboard seleccione el grupo 9 Para maderas generales seleccione el grupo 1 al 9 Para materiales desconocidos como papeles pintura etc 3 Consulte la operaci n procedimiento 5 2 Ejemplo Si la madera es LIME seleccione 4 Si el material es CHIPBOARD seleccione 9 3 Se recomienda que se inserten los electrodos tipo clavo a una profundidad m nima de 2 mm en el material bajo prueba Si no puede obtenerse con una profundidad de 2 mm inserte los electrodos de prueba a su m xima profundidad de prueba Fig 2 4 La pantalla mostrara el contenido de humedad en de contenido de humedad directamente e Sila muestra bajo prueba tiene una hume
6. dad Exactitud 4 5d 23 5 C Encima de la saturaci n de la fibra 25 a 30 lectura del valor aproximado referencia solamente Espec probado bajo el ambiente RF campo de fuerza menor que la frecuencia de 3vm menor que 30 MHz Sonda 2 Pines Tipo Electrodos para medici n de humedad Compensaci n de la Temperatura Compensaci n de temperatura manual del medidor en rangos de 0 a 50 C Calibraci n Funci n de calibraci n incorporada por medio de un bot n en el panel frontal Retenci n de Datos Presionando un bot n en el panel frontal Grabado en Memorias Graba las mediciones m xima y m nima Apagado Apagado manual y autom tico Tiempo de muestreo Aprox 0 8 segundos Temperatura de funcionamiento O a 50 C Humedad de operaci n Menos de 90 R H Fuente de alimentaci n Bater a de 9V DC tipo resistente 006P MN1604 PP3 o equivalente Corriente Aprox DC 5 8 mA Peso 330 g 0 73 LBS Dimensi n Instrumento 185x78x38 mm 7 3 x 3 1 x 1 5 pulg Sonda de humedad 23 mm Dia X 165 mm Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Instrumentos de Medici n Industrial 0 9 pulg Dia X 6 5 inch Accesorios Incluidos Manual de instrucci n 1 PC So
7. dad alta puede tardar unos minutos para obtener una lectura estable e Para un contenido de humedad gt 30 la pantalla mostrar u e Para un contenido de humedad lt 9 la pantalla mostrar 5 2 Medici n por m todo de referencia Para material no incluido en los grupos 1 9 el medidor de humedad puede usarse para referencia siguiendo el procedimiento indicado a continuaci n 1 Encender la unidad con el bot n de encendido Power Button 2 Seleccione el grupo de material 1 3 Inserte los electrodos tipo clavo en el material a prueba 4 La pantalla mostrar el contenido de humedad de referencia en Consideraci n Este valor es s lo para referencia Aunque los datos medidos son s lo para referencia puede Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilight twilight com mx Simi __ sa de cv Instrumentos de Medici n Industrial utilizarse para calcular la humedad de prueba simple Es una herramienta til para comprobar el contenido de humedad de referencia de tipos de materiales no incluidos en la tabla 1 5 3 Temp Ajuste de compensaci n El valor de la temperatura inicial del medidor de humedad es de 20 C 68 F La lectura del medidor puede ser corregida a adiendo 0 5 por cada 5 C menor a 20 C O restando 0 5 por cada 5 C e
8. era Grupo Queensland Kauri Queensland Walnut Ramin Redwood Baltic European Redwood Californian Rosewood Indian Santa Maria Sapele Seraya Red Silky Oak African Silky Oak Australian Spruce Norway European Spruce Sitka Sterculia Brown Stringybar Yellow Stringybar Messmate Sycamore Tallowwood Teak Totara Turpentine Utile Walnut African Walnut American Walnut European Walnut New Guinea Walnut Queensland Wandoo Wawa Whitewood Yew w Jw o WINY je jo oo SS Ul FP UI W W k W Www Wi W w0 Nje joa ju CO Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Instrumentos de Medici n Industrial 4 2 Clasificaci n por grupos de los 9 tipos de materiales grupos 1 al 9 tabla 2 Material Grupo 1 e Afara e Ash European e Ash Japanese e Balsa e Bange Wanga e Bosquiea e Boxwood Maracaibo e Cahoma e Cypress E African e Fir Grand e Gum American Red e Gum Spotted e Gurjun e Kapur e Karri e Kuroka e Maple Pacific e Maple Rock e Maple Sugar Material Grupo 2 e Ash American e Berlina e Canarium African Douglas Fir e Fir Douglas e Gum Saligna
9. estornillador ajuste VR1 hasta que el valor de indicaci n lea 18 0 Suelte el bot n la calibraci n est completa CALIBRACI N S lo presione el bot n de abajo continuamente Pantalla Fig 3 Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx twil Ent Instrumentos de Medici n Industrial 7 Mantenimiento 7 1 Remplazo de Bater a Una baja de la bater a se indica mediante LBT en la esquina izquierda de la pantalla Para reemplazar la bater a quite la tapa de la bater a con un destornillador o una moneda y reemplace con una bater a de 9 V de CC tipo resistente 006P MN1604PP3 o equivalente 7 2 Remplazo de los electrodos tipo clavo Para reemplazar los electrodos tipo clavo en la punta de prueba primero afloje la tuerca de seguridad en la base del electrodo hacia fuera y reemplace con nuevos Tuerca de fijaci n Fig 4 Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilight twilight com mx
10. ko e Keruing e Larch Western e Padauk African e Pillarwood Material Grupo 3 Pine Coriscan Pine Hoop Pine Nicaraguan Pitch Pine Ponderosa Pine Sugar Queensland Walnut Sapele Seraya Red Silky Oak African Silky Oak Australian Spruce Norway European Spruce Sitka Stringybar Yellow Stringybar Messmate Turpentine Walnut European Walnut Queensland Whitewood Yew Kauri New Zealand Lime Matai Oak Turkey Odoko Pine Kauri Pyinkado Totara Sycamore Teak Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilight twilight com mx twili int sa de cv Instrumentos de Medici n Industrial Material Grupo 6 e Afromorsia e Amboyna e Baswood e Coachwood e Muninga Material Grupo 7 e Gegu nohor e Guarea White Material Grupo 8 e Agba e Birch European e Cedar West Indian e Cheery European e Fir Noble e Guarea Black e Kauri Queensland e Mahogany African Material Grupo 9 e Chipboard 5 Procedimiento de Medici n Obeche Olivillo Persimmon Ramin Wawa Opepe Santa Maria Muhuhi Musine Musizi Queensland Kauri Utile Walnut African Wandoo Si los electrodos tipo clavo 3 12 Fig 1 no est n instalados en la punta de prueba por separado por favor consulte el siguiente diagrama para fijar los electrodos en l
11. na vez luego el s mbolo de Max aparecer en la pantalla con los valores m ximos b Presione RECALL Button otra vez el s mbolo Min aparecer en la pantalla con los valores m nimos c Para desactivar la funci n de registro de datos presione Record Button otra vez Todas las unidades asociadas mostradas desaparecer n de la pantalla LCD Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx ilismnt ITe sa de cv Instrumentos de Medici n Industrial 6 Calibraci n Retire la protecci n de hule 3 13 Fig 1 de los electrodos tipo clavo 3 12 Fig 1 1 Seleccione los grupos materiales al grupo 1 con el bot n de seleccionar material 3 8 Fig 1 Pulse simult neamente ambos botones de calibraci n bot n arriba abajo junto Presionar los dos al mismo tiempo mismo tiempo La pantalla contar hacia atr s de 5 a 1 despu s mostrar bueno 2 Sila pantalla muestra Err el metro tendr que ser re calibrado usando el siguiente m todo 3 Seleccione el grupo material 1 usando el bot n de seleccionar el Material Quite la tapa usando un destornillador peque o o una moneda Pulse y mantenga pulsado el bot n de calibraci n Con un d
12. ncima de 20 C Si la temperatura ambiente no es de 20 C y se requiere una medici n precisa se debe seguir el siguiente procedimiento TEMP ADJ Pantalla Presione el bot n de TEMP ADJ y el valor establecido inicial se mostrara en la pantalla a 20 C Ajuste presionando el bot n de Temp ADJ Derecho para aumentar 1 C o el bot n Temp ADJ Izquierdo para disminuir 1 C Cuando el valor de temperatura requerido est disponible espere unos 4 segundos para volver al modo de medici n autom ticamente Consideraci n Cuando la unidad est apagada durante el modo de ajuste de compensaci n de temperatura la nueva temperatura ser ignorada y el valor de configuraci n inicial por defecto otra vez ser de 20 C 5 4 Otras Funciones 1 Retenci n de datos Durante la medici n presione el bot n Hold Button 3 7 Fig 1 llevar a cabo los valores de visualizaci n amp la pantalla mostrar el s mbolo D H Para cancelar la funci n de retenci n de datos pulse el bot n de retenci n de datos Hold Button una vez m s 2 Registro de datos Max min de lectura La funci n de registro de datos muestra las lecturas m ximas y m nimas Para iniciar la funci n de grabaci n de datos presione el Record Button 3 4 Fig 1 una vez El marcador REC aparecer en la pantalla LCD Con el s mbolo de REC en la pantalla a Presione RECALL Button 3 5 Fig 1 u
13. nda de humedad 1 PC Extra electrodos tipo clavo 10 PCs Estuche duro 1PC 3 Descripci n del Panel Frontal 3 11 3 1 Enchufe de entrada de la sonda 3 2 Pantalla 3 3 Bot n de Encendido Apagado 3 4 Bot n de grabaci n 3 5 Bot n de Memoria 3 6 Temp Ajuste de compensaci n 3 7 Bot n de Retenci n de Datos HOLD 3 8 Bot n de Selecci n de material 3 9 Bot n de Calibraci n 3 10 Tapa Compartimiento de la Bater a 3 11 Sonda de mango 3 12 Electrodos tipo clavo 3 13 Protecci n de Hule Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Instrumentos de Medici n Industrial 4 Tabla de los 9 grupos de cada material madera 4 1 Clasificaci n por orden alfab tico a z tabla 1 Los nombres de los tipos de madera se encuentran en ingles debido al origen del instrumento Material Madera Grupo Abura Material Madera Grupo Afara Cheery European Afrormosia Chestnut Afzelia Chipboard Agba Coachwood Amboyna Cordia American Light Ash American Cypress E African Ash European Danta Ash Japanese Douglas Fir Ayan Elm English Baguacu Brazilian Elm Rock Balsa Elm
14. procesador asegura la m xima efectividad posible adem s cuenta con nuevas funciones especiales e Pantalla LCD de gran tama o con dos l neas de informaci n e Cuerpo compacto resistente y de alta duraci n dise ado para ser transportado f cilmente Prol Alfonso Reyes 2612 Col Del Paseo Residencial Ed Connexity Piso 7 Of 704 Monterrey Nuevo Le n 64920 Tel 81 8115 1400 LADA Sin Costo 01 800 087 4375 Email twilightOtwilight com mx Simi I sa de cv Instrumentos de Medici n Industrial e Almacena en memoria las lecturas M xima y M nima e Indicador de bater a baja incorporado e Sonda de humedad con extensi n de f cil operaci n y medici n remota e Apagado autom tico ayuda a conservar energ a 2 Especificaciones T cnicas Aplicaciones Para examinar la humedad en acabados y materiales en edificios y para la r pida medici n de humedad en madera Principal Utiliza 2 electrodos tipo clavo para medir la conductividad del material despu s la lectura se convierte en el contenido de humedad Memoria predeterminada para las especies 9 grupos de material en la memoria disponen de calibraciones para 150 especies diferentes de madera material Ref 4 1 4 2 Circuito Circuito micro procesador LSI Pantalla 13 mm 0 5 LCD S per Largo Medici n Mide la cantidad de humedad en rangos desde un 9 hasta 30 Resoluci n 0 1 contenido de hume