Home

D.B. Smith Professional Series Sprayers

image

Contents

1. Fountainhead Group Inc D B Smith Professional Series Sprayers Use and Care Manual Style R Style A CAUTION Read and follow all instructions Do Not Return This Sprayer To The Store For Help Information or Parts Call 1 800 311 9903 The Fountainhead Group Inc 23 Garden St New York Mills NY 13417 1 800 311 9903 www TheFountainheadGroup com Manual No 181959 Rev B 1 8 13 ECN13 001 5 1 2 x 8 1 2 Booklet A SAFETY PRECAUTIONS e Read owner s manual completely before operating this sprayer Always use goggles gloves and protective clothing when using sprayer Read and follow all instructions and cautions on label of products used in this sprayer Never use flammable liquids caustics acids or hot water in this tank Do not leave sprayer in the sun when not in use Spray when air is calm to prevent drift of chemicals Do not use sprayer near open flame or anything that could cause ignition of the spray Always inspect hose and all hose connections before each use A damaged hose or loose hose connection can result in unintended exposure to the pressurized chemical resulting in serious injury or property damage not lift or carry sprayer by the hose shut off valve or extension Carry by pump handle only making sure handle is properly locked in place before lifting not pressurize with any mechanical device such as air compre
2. 0 1 Inspeccione la empaquetadura Si est gastada o da ada s quela y reempl cela Vea la Figura 1 2 Para desensamblar la tapa de la bomba o el cilindro de la bomba apriete las trabillas Vea la Figura 2 que traban el cilindro a la tapa y mientras apoya el sujetador de extensi n sobre una mesa o banco gire el cilindro en sentido antihorario para destrabar Vea la Figura 3 Figura 1 Figura 2 p gina 15 MANTENIMIENTO continuacion 3 Inspeccione la junta t rica Si est gastada da ada s quela y reempl cela Lubrique la junta t rica con gel de petr leo Vea la Figura 4 4 Inspeccione la v lvula de retenci n en el fondo del cilindro Si est gastada o da ada s quela y reempl cela presionando en el orificio en el fondo del cilindro Vea la Figura 5 5 Reinstale el cilindro en la tapa Mientras sujeta la tapa firmemente gire el cilindro en sentido horario para fijar las trabillas en su lugar Figura 5 Estilo R 1 Inspeccione la empaquetadura Si est gastada o da ada s quela y reempl cela Vea la Figura 6 2 Para sacar la tapa de la bomba del cilindro de la bomba retire los tornillos que aseguran la tapa de la bomba al tubo Vea la Figura 7 Figura 6 Figura 7 3 Inspeccione la junta t rica Si est gastada o da ada s quela y reempl cela Lubrique la junta t rica con gel de petr leo Vea la Figura 8 4 Inspeccione la v lvula de retenci n en el fondo del cilin
3. bomba se eleva cuando se lo destraba La manguera tiene una p rdida en el tanque o en el dispositivo de cierre Atomizador dificil de bombear El tanque del atomizador tiene una p rdida La boquilla gotea cuando se suelta la palanca de la v lvula de paso La punta de la boquilla sechorrea patr n de aspersi n d bil aspersi n parcial o bloqueo completo El seguro del dispositivo de cierre est activado 1 Hay suciedad o residuos en la empaquetadura de la bomba No 2F No 5G o No 6B o en el cierre 2 Empaquetadura de bomba No 2F No 5G o No 6B astillada rasgada dilatada o defectuosa 3 Revise la v lvula No 2G No 5H en la parte inferior del ensamblado de la bomba 4 Junta t rica gastada o da ada 20 0 6 sobre el pist n 1 Suciedad o residuos debajo de la v lvula de retenci n No 2G No 5H No 6A de la bomba 2 V lvula de retenci n No 2G No 5H o No 6A de bomba astillada rasgada o dilatada 1 Manguera suelta 2 Manguera agrietada dilatada o defectuosa 1 La junta t rica del pist n No 2D o No 6C est da ada 2 La junta t rica del pist n No 2D o No 6C est seca 1 Suciedad o residuos en la v lvula del dispositivo de cierre 2 Junta t rica o sello da ado en el dispositivo de cierre Kit No 11 1 Falta el sello plano o est da ado 2 La extensi n de aspersi n o la boquilla est n bloqueadas BUSCAR SOLUCI N Pre
4. 6 2 Piston o ring 2D or 6 is dry Sprayer is difficult to pump LOOK FOR REMEDY Squeeze shut off lever and rotate the lock towards the nozzle as described in Spraying and Locking section 1 Clean dirt or debris from gasket 2F 5G or 6B or closure 2 Remove old gasket 2F 5G or 68 and replace with new as described in Pump Disassembly amp Reassembly section 3 Replace if missing or damaged as described in Pump Disassembly amp Reassembly section 4 Replace if worn or damaged as described in Pump Disassembly amp Reassembly section 1 Clean check valve 2G 5H or 6A and valve sealing surface on pump 2 Replace check valve 2G 5H or 6A as described in Pump Disassembly amp Reassembly section 1 Tighten hose nut 2 Replace shut off assembly 1 Replace piston o ring as described in Pump Disassembly amp Reassembly section 2 Lubricate piston o ring as described in Pump Disassembly amp Reassembly section Evidence of spray material Sprayer tank leaks escaping from the tank Replace entire sprayer 1 Dirt or debris in shut off valve 2 Damaged o ring or seal in shut off kit 11 Nozzle drips when shut off lever is released 1 Flat seal is missing or damaged 2 Spray extension or nozzle clogged Nozzle tip leaks poor spray pattern partial spray or com plete stoppage 1 Clean shut off as described in Shut off Maintenance section 2 Servi
5. atomizar de forma continua presione la palanca y gire el seguro Vea la Figura H 3 Retire el seguro si es necesario y suelte la palanca del dispositivo de cierre para dejar de atomizar 4 Gire la punta de la boquilla para ajustar el patr n del rociado Libere la presi n del tanque V lvula de liberaci n de presi n PRV en modelos seleccionados 1 SINPRV Coloque el tanque de costado con la salida de la manguera en la parte inferior Dirija la boquilla en sentido contrario a usted y presione la palanca de cierre hasta que la unidad deje de rociar Vea la Figura 1 2 CON PRV Jale hacia arriba la perilla de la v lvula de liberaci n de presi n hasta que toda la presi n del tanque se haya liberado Vea la Figura J Figura Figura J pagina 14 INSTRUCCIONES DE OPERACI N continuaci n Finalizaci n 1 Despresurice el tanque seg n se describe en la secci n Libere la presi n del tanque 2 Gire el mango de la bomba en sentido antihorario para quitar la bomba 3 Vacie todo el l quido restante de acuerdo con las intrucciones de desecho del producto 4 Siga las instrucciones de Limpieza Limpieza 1 Quite la bomba seg n se describe en la secci n Finalizaci n 2 Llene el tanque con agua de grifo fresca y limpia Vuelva a colocar la bomba y aj stela firmemente 3 Agite el tanque para quitar el producto qu mico de la pared del tanque y la bomba 4 Quite la bomba y vac e el conten
6. bomba o la soluci n le haga contacto con su querpo resultando en lesi n grave Limpie y enjuague el atomizador completamente despu s de cada uso Nunca intente modificar la condici n original del atomizador Siempre utilice las piezas de reemplazo del fabricante original Mantenga el atomizador y todas las sustancias qu micas fuera del alcance de los ni os ADVERTENCIA SIEMPRE LIMPIE EL ROCIADOR Y CIERRELO BIEN DESPU S DE CADA USO O CUANDO CAMBIE LAS APLICACIONES COMO SE DESCRIBE EN LA SECCI N LIMPIEZA EL NO CUMPLIR CON LIMPIAR COMPLETAMENTE EL ROCIADOR PODR A PROVOCAR CONTAMINACI N CRUZADA APRECAUCI N Siempre vac e limpie y seque el tanque el sistema de bomba cierre manguera y extensi n despu s de cada uso Si no lo hace los componentes del atomizador podr an deteriorarse y romperse cuando est n presurizados Si no limpia el atomizador y no le da un mantenimiento adecuado se cancelar la garant a del fabricante AADVERTENCIA El atomizador funciona con l quido a presi n Si no lo maneja con cuidado o no sigue las instrucciones de operaci n y limpieza podr a ocasionar el deterioro o la ruptura del tanque manguera y otras piezas que est n bajo presi n Esto puede provocar lesiones graves debido a la descarga de l quidos a alta presi n o a la expulsi n forzada de las piezas No use materiales inflamables en este atomizador El material podr a encenderse o explotar y provocar lesiones gra
7. en la etiqueta de los productos que se usan en este atomizador Nunca utilice l quidos inflamables agentes c usticos cidos o agua caliente en este tanque No deje el atomizador expuesto al sol cuando no est en uso Utilice el atomizador cuando no haya viento para evitar el desplazamiento de sustancias qu micas No use el atomizador cerca de llamas o agentes que pudieran ocasionar que se encienda la soluci n de rociado Siempre revise la manguera y todas las conexiones de la misma antes de cada uso Una manguera da ada o una con exi n suelta pueden ocasionar una exposici n no deseada a la sustancia qu mica presurizada lo cual podr a provocar lesiones graves o da os a la propiedad No levante ni transporte el atomizador por la manguera la v lvula de cierre o extensi n Cargue la bomba por el mango solamente cercior ndose de que el mango est debidamente enganchado en posici n antes de levantar No presurice con ning n dispositivo mec nico como un compresor de aire ya que puede generar niveles de presi n peligrosos y algunas piezas podr an estallar lo cual ocasionar a lesiones graves S lo use la bomba original No almacene sustancias qu micas en este tanque Siempre alivie la presi n cuando el rociador no est en uso y antes de quitar la bomba del tanque No se pare con lacara o el cuerpo sobre la parte superior del tanque cuando bombea o afloja la bomba para evitar que la
8. CI N Las selecciones de boquilla var an por modelo 505 de las boquillas cono ajustables Usos de las boquillas espumantes e Rociado localizado en o alrededor de Rociado localizado de arriates arriates rboles o arbustos trad Bordes a lo largo de cercas entradas 2 alrededor de arboles arbustos e Destrucci n de malezas por e Bordes a lo largo de cercas ejemplo hiedra venenosa roble entradas y caminos venenosa kudzu y zarzamora Destrucci n de malezas por silvestre ejemplo hiedra venenosa roble e Preparaci n de arriates de jard n venenoso kudzu y zarzamora para sembrar plantas ornamentales silvestre y vegetales A Tuerca ciega B Boquilla para espuma Usos de las boquillas roja con Usos de las boquillas amarilla con C Boquilla de cono adjustable ventilador para alto volumen ventilador para bajo volumen D Boquilla roja con ventilador e Reemplazo de c sped Mate el e Para un roc o de precisi n en para alto volumen c sped y las malezas antes de zonas confinadas tales como E Boquilla amarilla con ventilador sembrar el c sped nuevo jardines y maceteros para bajo volumen Preparaci n de reas grandes Sello plano para el sembrado de plantas G Adaptador ornamentales y vegetales H Extensi n p gina 13 INSTRUCCIONES DE OPERACION IMPORTANTE Siempre asegurese de que se ha liberado la presion d
9. ENCI N 68 181203 EMPAQUETADURA R DE LA BOMBA ANILLO O DEL PISTON R DE LA PIEZAS DE CIERRE SMITH PRO II No DE No DE DESCRIPCION CLAVE PIEZA ENSAMBLADO DE LA EXTENSI N DE 14 SMITH PRO II ENSAMBLADO DE LA EXTENSI N DE 18 SMITH PRO II ENSAMBLADO DE LA EXTENSION DE 21 SMITH PRO II ENSAMBLADO DE LA EXTENSI N DE 21 ACERO INOXIDABLE SMITH PRO II ENSAMBLADO DEL CIERRE SMITH PRO ll 1 GAL N ENSAMBLADO DEL CIERRE SMITH PRO ll 2 GALONES ENSAMBLADO DEL CIERRE SMITH PRO ll 3 GALONES 7 182112 181817 181818 181819 KIT No 9 181869 JUEGO DE BOQUILLA DE POLICARBONATO BOQUILLA DE POLICARBONATO AJUSTABLE BOQUILLA AMARILLA DE VENTILADOR PLANO BAJO VOLUMEN BOQUILLA ROJA DE VENTILADOR PLANO ALTO VOLUMEN 90 180266 BOQUILLA PARA ESPUMA 181812 SELLO DE BOQUILLA PLANA 181804 TUERCA CIEGA DE BOQUILLA KIT No 10 181870 JUEGO DE BOQUILLA DE COBRE 181823 BOQUILLA DE COBRE AJUSTABLE BOQUILLA AMARILLA DE VENTILADOR 180168 PLANO BAJO VOLUMEN BOQUILLA ROJA DE VENTILADOR 180097 PLANO ALTO VOLUMEN 180266 BOQUILLA PARA ESPUMA 00 181812 SELLO DE BOQUILLA PLANA 181804 TUERCA CIEGA DE BOQUILLA KIT No 11 181910 JUEGO DE MANTENIMIENTO DE DESPOSITIVO DE CIERRE SMITH PRO 181812 SELLO DE BOQUILLA PLANA 2 11F 181810 ANILLO O DE VARILLA 116 181805 DE BOQUILLA AJUSTABLE p gina 19 LO
10. FF ASSEMBLY SMITH PRO 1 GAL 181818 SHUT OFF ASSEMBLY SMITH PRO II 2 GAL 181819 SHUT OFF ASSEMBLY SMITH PRO 3 GAL KIT 9 181869 POLY NOZZLE KIT 9A 181804 KIT 10 181870 BRASS NOZZLE KIT 10A 108 10C FLAT NOZZLESEAL _ B 90 10 181812 FLAT NOZZLE SEAL 10F 181804 NOZZLE CAP NUT KIT 11 181910 SMITH PRO II SHUT OFF SERVICE KIT 181812 FLAT NOZZLE SEAL 2 181810 WAND O RING 181805 ADJUSTABLE NOZZLE O RING Page 9 SERVICE KITS PARTS amp ACCESSORIES ARE AVAILABLE BY CONTACTING The Fountainhead Group Inc Customer Service Center Monday Friday 8 A M 5 P M EST Toll Free 1 800 311 9903 or e mail Info TheFGI com or Access online at www TheFountainheadGroup com Page 10 Fountainhead Group Inc Manual de uso y cuidado Estilo Estilo R PRECAUCI N Lea y siga todos las instrucciones No devuelva este atomizador a la tienda Para obtener ayuda informaci n o piezas llame al 1 800 311 9903 The Fountainhead Group Inc 23 Garden St New York Mills NY 13417 1 800 311 9903 www TheFountainheadGroup com Manual No 181959 Rev B 1 8 13 ECN13 001 AAPRECAUCIONES DE SEGURIDAD Lea todo el manual del usuario antes de operar este atomizador Siempre utilice gafas de seguridad guantes y ropa protectora cuando use el atomizador Lea y siga todas las instrucciones y precauciones que se muestran
11. Nozzle Maintenance 1 If nozzle clogs remove and disassemble the nozzle assembly 2 Clean the openings of any obstructions and reassemble Page 6 Shut off Maintenance Smith Pro II Always depressurize sprayer before maintenance by activating shut off and spraying contents out 1 Unscrew the handle from the shut off assembly 2 Remove the filter from the shut off assembly 3 Clean any debris from inside the handle shut off assembly or the filter by rinsing with cool clean water 4 Reassemble the components as shown and tighten all connections securely A Handle B Filter C Shut off Assembly TROUBLESHOOTING TROUBLE Sprayer starts to spray when pumping or sprayer will not stop spraying when shut off lever is released Shut off lock is engaged 1 Dirt or debris on pump gasket 2F 5G or 6B or closure 2 Chipped torn swollen or defective pump gasket 2F 5G 68 3 Check valve 20 5H or 6A at bottom of pump assembly 4 Worn or damaged o ring 2D or 6C on piston Sprayer leaks at pump or sprayer does not build pressure 1 Dirt or debris under check valve 2G 5H or 6A on pump 2 Chipped torn or swollen pump check valve 2G 5H or 6 Sprayer material overflows through pump barrel or pump handle rises when handle is unlocked 1 Loose hose 2 Cracked swollen or faulty hose Hose leaks at tank or shut off 1 Damaged piston o ring 2D or
12. S JUEGOS DE REPARACION PIEZAS ACCESORIOS SE ENCUENTRAN DISPONIBLES COMUNICANDOSE A The Fountainhead Group Inc Centro deservicio al cliente De lunes a viernes 8 5 EST Llame sin costo al 1 800 311 9903 Correo electr nico Info TheFGI com O Ingrese en l nea a www TheFountainheadGroup com p gina 20
13. according to the product disposal directions 4 Follow the Cleaning instructions Cleaning 1 Remove the pump as described in the Finish section 2 Fill the tank with cool clean tap water Replace the pump and tighten securely 3 Agitate the tank to rinse the chemical from the tank wall and pump 4 Remove the pump and empty the contents into gravel or bare soil 5 Refill the tank with cool clean tap water 6 Make sure the pump is free of dirt or debris and reinstall into the tank Tighten securely 7 Pressurize the tank as described the Pressurizing section 8 Direct the nozzle away from you and activate the shut off for at least 30 seconds to clean the hose and shut off 9 Release pressure as described in the Release Tank Pressure section 10 Remove the pump and empty the contents into gravel or bare soil 11 Repeat steps 5 10 until thoroughly cleaned Sprayer Storage 1 Sprayer tank should be hung upside down with the pump removed 2 Do not store or leave any solution in the tank after use 3 Store in a warm dry location out of direct sunlight 4 Keep the sprayer and all chemicals out of the reach of children MAINTENANCE Pump Lubrication Pump should be periodically oiled by applying 10 to 12 drops of light oil down the pump rod through the opening in the pump cap as shown O Style R Style Pump Disassembly amp Reassembly NOTE Remove pump from tank prior to disas
14. ce shut off seals as described in Maintenance service kit 11 1 Replace flat seal at extension tip kit 11 2 Remove nozzle and clean as described in Nozzle Maintenance section Page 7 KITS PARTS amp ACCESSORIES i 4 J KIT 11 aa ce 55 9 O gt gt 53 _ _ Page 8 O SPRAYER PARTS 181052 1 GALLON O TANK 2 181036 2 181120 3 GALLON O TANK 1 K IT 2 A B C D E 180398 O PUMP 178040 CAP 180279 HANDLE 180278 ROD R SPRAYER PARTS KEY PART DESCRIPTION 5 181828 2 GALLON R TANK INCLUDES KEY 4 3 GALLON R TANK INCLUDES KEY 4 180836 PRV ASSEMBLY 5 181911 PUMP SA 181630 HANDLE 58 182129 Pume sewa 50 181935 55 181834 se 56 181203 1 KIT 6 182046 PUMP SERVICE KIT 171015V CHECK VALVE VITON 68 181203 R PUMP GASKET 180861 R PUMP PISTON O RING SMITH PRO II SHUT OFF PARTS KEY PART DESCRIPTION 181845 181843 18 EXTENSION ASSEMBLY SMITH PRO II 181824 21 EXTENSION ASSEMBLY SMITH PRO 21 EXTENSION ASSEMBLY 182112 STAINLESS STEEL SMITH PRO 1 181817 SHUT O
15. d trees and shrubs Spot spraying or around flower 1 1 Edging along fences driveways Killing brush such as poison ivy and walkways poison oak kudzu and wild Killing brush such as poison blackberry ivy poison oak kudzu and wild Preparing garden beds for planting of ornamentals and vegetables A Cap Nut B Foaming Nozzle RED HIGH VOLUME YELLOW LOW VOLUME C Adjustable Cone Nozzle FAN NOZZLE USES FAN NOZZLE USES D Red High Volume Fan Nozzle E Yellow Low Volume Fan Nozzle e Lawn replacement Kill lawn e For precision spraying in F Flat Seal and weeds before planting a confined areas such as G Adapter new lawn gardens and flower beds H Extension e Preparing large areas for paa planting of ornamental and vegetable gardens Page 3 OPERATING INSTRUCTIONS Filling IMPORTANT Always make sure the pressure is released from the tank before filling or servicing If equipped pull up on the knob of the pressure release valve until all the pressure is released from the tank Otherwise squeeze and hold shut off lever until the unit stops spraying Then and only then it is safe to remove pump 1 Turn the pump handle counterclockwise to remove the pump See Figure E 2 Fill the tank to the desired level See fill markings on side of tank Always refer to chemical manufacturer for proper mixture 3 Install the pump into the tank opening and turn Figur
16. dro Si est gastada o da ada s quela y reempl cela presionando en el orificio en el fondo del cilindro Vea la Figura 9 5 Inserte el ensamblado del mango de la bomba en el cilindro de la bomba Alinee los orificios de la tapa de la bomba y el cilindro Coloque nuevamente los tornillos y aj stelos firmemente A Figura 8 Figura 9 Mantenimiento de la boquilla 1 Sila boquilla se atasca retirela y desarme el ensamblaje de la boquilla 2 Retire todas las obstrucciones presentes en las aberturas y vuelva a ensamblar pagina 16 Mantenimiento del dispositivo de cierre Smith Pro Siempre despresurice el atomizador antes de darle mantenimiento al activar el cierre y atomizador los contenidos hacia afuera 1 Destornille el mango del dispositvo de cierre 2 Retire el filtro del dispositivo de cierre 3 Limpie todo residuo presente en el interior del mango del despositivo de cierre en el asiento de valvula filtro 4 Vuelva a ensamblar los componentes segun se muestra en la A Mango B Filtro C Dispositivo de cierre figura y apriete todas las conexiones hasta que queden aseguradas SOLUCI N DE PROBLEMAS PROBLEMA El atomizador empieza a rociar al bombear o el atomizador no deja de rociar cuando el gatillo de cierre se libera El atomizador tiene una p rdida en la bomba o el atomizador no acumula presi n El material del atomizador se derrama por el cilindro de la bomba o el mango de la
17. e Figure F clockwise until tightly sealed against the tank See Figure F Pressurizing 1 Make sure shut off lock is not engaged If shut off lock is engaged while pressurizing the unit will immediately start spraying 2 Push down on the handle and turn counterclockwise to unlock the handle See Figure G 1G 3 Pressurize the sprayer by pumping the handle in a smooth up and down motion See Figure G 2G 4 Push down on the handle and turn clockwise to lock the handle into the pump See Figure G 3G Spraying and Locking 1 Direct nozzle away from you and squeeze shut off lever to begin spraying 2 For continuous spraying squeeze lever and rotate lock See Figure 3 Unlock if needed and release shut off lever to stop spraying 4 Turn the nozzle tip to adjust the spray pattern Release Tank Pressure Pressure Release Valve PRV on select models PRV Lay the tank on its side with the hose outlet on the bottom Direct the nozzle away from you and squeeze the shut off lever until the unit stops spraying See Figure 2 WITH PRV Pull up on the knob of the PRV until all pressure is released from the tank See Figure J Figure Figure J Page 4 OPERATING INSTRUCTIONS CONTINUED Finish 1 Depressurize the tank as described in Release Tank Pressure section 2 Turn the pump handle counterclockwise to remove the pump 3 Empty any remaining liquid
18. el tanque antes o utilizar Si provista jale hacia arriba la perilla de la valvula de liberaci n de presi n hasta que se libere toda la presi n del tanque De lo contrario apriete y sostenga la palanca de la v lvula de cierre hasta que la unidad deje de rociar Despu s y solamente despu s es seguro quitar la bomba 1 Gire el mango de la bomba en sentido antihorario para quitar la bomba Vea la Figura E 2 Llene el tanque al nivel deseado Ver llenan se ales en el lado del tanque Consulte siempre las intrucciones del fabricante del producto qu mica para la mezcla apropiada 3 Coloque la bomba en el orificio del tanque y g rela en sentido horario hasta ajustarla frimemente al tanque Vea la Figura F Figura E Figura F Presurizaci n 1 Aseg rese de que el seguro del mango de cierre no est trabado si el seguro del mango de cierre est trabado durante la presurizaci n la unidad comenzar a rociar de immediato 2 Empuje hacia abajo el mango y girelo en sentido antihorario para destrabar el mango Vea la Figura G 1G 3 Presurice el atomizador bombeando el mango con un movimiento uniforme hacia arriba y hacia abajo Vea la Figura G 2G 4 Empuje el mango hacia abajo y g relo en sentido horario para trabar el mango en la bomba Vea la Figura G 3G Figura G Atomizar y asegurar 1 Dirija la boquilla lejos de usted y presione la palanca de cierre para empezar a atomizar 2 Para
19. ido sobre gravilla o suelo descubierto 5 Vuelva a llenar el tanque con agua de grifo fresca y limpia 6 Aseg rese de que la bomba est limpia y libre de residuos y vuelva a instalarla en el tanque Aj stela firmemente 7 Presurice el tanque tal como se describe en la secci n Presurizaci n 8 Dirija la boquilla lejos de usted y active el dispositivo de cierre durante por lo menos 30 segundos para limpiar la manguera y el dispositivo de cierre 9 Libere la presi n tal come se describe en la secci n Libere la presi n del tanque 10 Quite la bomba y vac e el contenido sobre gravilla o suelo descubierto 11 Repita los pasos 5 a 10 hasta que la unidad est completamente limpia Alamacenamiento del atomizador 1 El tanque del atomizador debe colgarse en posici n invertida y sin la bomba 2 No almacene ni deje soluci n dentro del tanque despu s del uso 3 Gu rdelo en un lugar templado y seco alejado de la luz solar directa 4 Mantenga el atomizador y todos los productos qu micos lejos del alcance de los ni os MANTENIMIENTO LOGS Lubricacion de la bomba La bomba se debe aceitar periddicamente aplicando 10 6 12 gotas de aceite liviano en la varilla de la bomba por la abertura de la tapa de la bomba como se muestra e 7 4 Desensamblar volver a ensamblar la bomba Estilo Estilo R NOTA Saque la bomba del tanque antes de desensamblar Seg n se muestra en la variedad de modelos Estilo
20. lo plano la punta de la extensi n juego No 11 2 Retire la boquilla y limpie tal como se describe en la secci n Mantenimiento de la boquilla p gina 17 JUEGOS PIEZAS ACCESORIOS No 10 LO a A Poe Za KIT 9 25 4 Zo pagina 18 PARTES DEL ATOMIZADOR No DE No DE DESCRIPCION CLAVE PIEZA 181052 TANQUE O DE 1 GAL N 1 181036 TANQUE O DE 2 GALONES 181120 TANQUE O DE 3 GALONES KIT No 2 180398 LA BOMBA 0 178040 O DE LA BOMBA 180279 MANGO O DE LA BOMBA 180278 VARILLA O DE LA BOMBA ENSAMBLADO DEL PIST N O DE LA 178041 CILINDRO O DE LA BOMBA EMPAQUETADURA O DE LA BOMBA 171015V V LVULA DE RETENCI N VITON PARTES DEL ATOMIZADOR R No DE No DE DESCRIPCI N CLAVE PIEZA TANQUE DE 1 GAL N INCLUYE 2 181828 CLAVE NO 4 3 TANQUE DE 2 GALONES INCLUYE 181837 CLAVE NO 4 180836 ENSAMBLAJE DEL PRV KIT No 5 181911 LA BOMBA MANGO DE LA BOMBA TORNILLO DE LA BOMBA 2 CUBIERTA R DE LA BOMBA VARILLA R DE LA BOMBA ENSAMBLADO DEL PIST N R DE LA CILINDRO O DE LA BOMBA 181203 EMPAQUETADURA R DE LA BOMBA V LVULA DE RETENCI N KIT No 6 182046 JUEGO DE MANTENIMIENTO DE BOMBA 171015V V LVULA DE RET
21. sembly As shown on varying models O Style 1 Inspect gasket If worn or damaged remove and replace See Figure 1 2 To disassemble pump cap from pump barrel squeeze the tabs See Figure 2 that lock the barrel to the cap and while resting the extension clip on a table or bench turn the barrel counterclockwise to unlock See Figure 3 A Figure 1 Figure 2 Figure 3 Page 5 MAINTENANCE CONTINUED 3 Inspect o ring If worn or damaged remove and replace Lubricate o ring with petroleum jelly See Figure 4 4 Inspect check valve in bottom of barrel If worn or damaged remove and replace by pressing into hole in bottom of barrel See Figure 5 5 Re install the barrel into the cap While holding the cap securely turn the barrel clockwise to lock the tabs in place Figure 4 Figure 5 R Style 1 Inspect gasket If worn or damaged remove and replace See Figure 6 2 To remove pump cap from pump barrel remove screws securing pump cap to barrel See Figure 7 Figure 6 Figure 7 3 Inspect o ring If worn or damaged remove and replace Lubricate o ring with petroleum jelly See Figure 8 4 Inspect check valve in bottom of barrel If worn or damaged remove and replace by pressing into hole in bottom of barrel See Figure 9 5 Insert the pump handle assembly into the barrel Align the holes in the pump and barrel Reinstall screws and tighten securely Figure 8 Figure 9
22. sione la palanca de cierre y suelte el seguro Vea la secci n Atomizar y asegurar 1 Limpie la suciedad o los residuos de la empaquetadura No 2F No 5G o No 6B o el cierre 2 Retire la empaquetadura No 2F No 5G o No 6B y reempl cela con una nueva como se describe en la secci n Desensamblar y volver a ensamblar la bomba 3 Reemplace ante ausencia o da os como se describe en la secci n Desensamblar y volver a ensamblar la bomba 4 Reemplace si est gastada o da adacomo se describe en la secci n Desensamblar y volver a ensamblar la bomba 1 Limpie la v lvula de retenci n No 2G No 5H No 6A y la superficie sellada de la v lvula de la bomba 2 Reemplace la v lvula de retenci n No 2G No 5H o No 6A como se describe en la secci n Desensamblar y volver a ensamblar la bomba 1 Ajuste la tuerca de manguera 2 Reemplace el conjunto de cierre 1 Reemplace la junta t rica del pist n come se describe en la secci n Desensamblar y volver a ensamblar la bomba 2 Lubrique la junta t rica del pist n como se describe en la secci n Desensamblar y volver a ensamblar la bomba Hay evidencia de escape del Reemplace todo atomizador material de rociado del tanque 1 Limpie el dispositivo de cierre tal como se describe en la secci n Mantenimiento del dispositivo de cierre 2 D le mantenimiento a los sellos de cierre tal como se describe en juego de mantenimiento No 11 1 Reemplace el sel
23. ssor since this can create dangerous pressure level and bursting of parts resulting in serious injury Only use original pump Do not store chemicals in this tank Always release pressure when sprayer 15 not in use and before removing pump from tank not stand with face or body over top of tank when pumping or loosening pump to prevent pump solution from striking you resulting in serious injury Clean and rinse sprayer thoroughly after each use Never attempt to alter sprayer from original condition Always use replacement parts from original manufacturer Keep the sprayer and all chemicals out of the reach of children A WARNING ALWAYS CLEAN THE SPRAYER AND SHUT OFF THOROUGHLY AFTER EACH USE OR WHEN CHANGING APPLICATIONS AS DESCRIBED IN THE CLEANING SECTION FAILURE TO COMPLETELY CLEAN MAY CAUSE CROSS CONTAMINATION A CAUTION Always empty clean and dry tank pump system shut off hose and extension after each use FAILURE TO DO SO MAY WEAKEN SPRAYER COMPONENTS CAUSING COMPONENTS TO RUPTURE WHEN PRESSURIZED Additionally FAILURE TO CLEAN AND PROPERLY MAINTAIN YOUR SPRAYER WILL VOID MANUFACTURER S WARRANTY AWARNING The sprayer is operated with liquid under pressure Failure to observe caution and to follow instructions for operating and cleaning can cause tank hose and other parts to be weakened and rupture under pressure This can result in serious injury from high pressure discharge of liq
24. uids or forcible ejection of parts Do not use flammable materials in this sprayer Material could ignite or explode causing serious injury and or possible death For safe use of this product you must read and follow all instructions before use TEST SPRAYER WITH WATER BEFORE USING ANY CHEMICALS Do not return sprayer to store if you experience problems or have questions contact our toll free Customer Service Center M F 8A M 5P M EST at 1 800 311 9903 or e mail Info TheFGI com or access online at www TheFountainheadGroup com Page 2 ASSEMBLY INSTRUCTIONS METE Assemble Hose To Tank IMPORTANT Do not attempt to heat or alter hose hose nut or barb prior to assembly 1 Align hose barb tabs push hose barb into tank until it stops See Figure A 2 Slide hose nut into place and turn clockwise to tighten See Figure B NOTE Do not use tools to tighten hose nut Figure A Figure B Assemble Extension Shut Off amp Nozzle Figure 0 Figure 1 Install the extension onto the shut off gt assembly and tighten the nut securely See Figure C 2 Install selected nozzle onto the end of the extension and tighten securely See Figure D SELECT USING NOZZLE CHART BELOW Nozzle selections vary by model ADJUSTABLE CONE USES FOAMING NOZZLE USES beds 665 201 8 4147 Spot spraying in flower beds alona i dri walkways driveways and dging along fences driveways patios aroun
25. ves y o muerte Para usar este producto de manera segura debe leer y seguir todas las instrucciones antes de usarlo PRUEBE EL ATOMIZADOR CON AGUA ANTES DE USAR SUSTANCIAS QU MICAS No devuelva el atomizador a la tienda si tiene problemas o preguntas comun quese con nuestro Centro de servicio al cliente llamando a la l nea gratuita 1 800 311 9903 de lunes a viernes de 8 A M a 5 P M hora del este escribiendo por correo electr nico a Info TheFGI com o accediendo en l nea a www TheFountainheadGroup com p gina 12 INSTRUCCIONES DEL ENSAMBLAJE Ensamble la manguera en el tanque IMPORTANTE No intente calentar ni alterar la manguera tuerca de manguera conector dentado antes del ensamblado 1 Alinee las lenguetas de la espiga de la manguera presione la espiga de la manguera en el tanque hasta que se detenga Vea la Figura 2 Deslice la tuerca de la manguera hasta su lugar y gire en sentido horario para ajustar Vea la Figura B Figura A Figura B NOTA No utilice herramientas para ajustar la tuerca de la manguera Ensamblado de la extensi n el cierre y la boquilla 1 Instale la extensi n en el dispositivo de cierre y ajuste la tuerca hasta que est segura Vea la Figura 2 Instale la boquilla seleccionada en Figura C Figura D extremo de la extension y apriete hasta que est segura Vea la Figura D SELECCIONE UTILIZANDO LA TABLA DE BOQUILLAS QUE SE MUESTRA A CONTINUA

Download Pdf Manuals

image

Related Search

Related Contents

Troy-Bilt 2100 Snow Blower User Manual  Elección correcta regulador climático  User Manual - TVprzemyslowa.pl  + アルサッ ト ALー 。 (\4~743)  HI 9835 HI 98360 - Hanna Instruments Portugal  取扱説明書  Kicker 5-Channel Owner's Manual  Gosafe G777/G797  ー - GM。インタ一ネツ ト欄会社 (以下` 「当祖 といいます.) は、 GMOと  ストレ࣭ジKK 本体上置き 組立説明書 注意 部材 注意 - Garage  