Home
Quick Start User Guide
Contents
1. Dear FORA D30 System Owner Thank you for choosing FORA D30 Blood Glucose Plus Blood Pressure Monitoring System to take control of your diabetes Being a home care device this system is helpful in tracking your blood glucose and blood pressure values The Quick Start User Guide will assist you in setting up the system and testing your blood glucose levels Please read it carefully before use For complete information on the system s use and features please refer to the Owner s Manual BLOOD GLUCOSE PLUS BLOOD PRESSURE MONITORING SYSTEM Test Strip Vial Control Solution Test Strips for obtaining blood from 2 ba places otherthan your Lancets Clear Cap fingertip Please note Use only FORA D30 test strips with FORA D30 monitor Adjustable Tip Arrow Ejector Cocking Control g Us i Quick Start User Guide For self testing Read instructions before use For In vitro diagnostic use Distributed by Fora Care Fora Care Inc 810 Lawrence Dr Suite 104 Newbury Park CA 91320 USA Products made in Taiwan Toll Free 1 888 307 8188 8 30am 5 00pm PST Mon Fri Depth 1 866 469 2632 24 Hours 7 days week Indicator www foracare com usa Release Button 315 3252000 003 Front View of Monitor Test Slot Up Down Button Pressure Cuff BT Indication Light Test Strip Ejector Data Port Repeat Button For FORA D30e S Button Earphone Jack M Button DC Adapter
2. Port On Off Button Display Screen Rear View of Monitor Battery Compartment Battery Cover 3 Test Your Blood Glucose 4 Read Your Result 1 Set the Monitor amp Press S to start setting Year flashes first Press to change values to increase the number more quickly Press to move on to the next step Date flashes Follow IB2 to make changes The sequence of settings is 1 date 2 time format 3 date 4 unit of blood glucose 5 unit of temperature a S a Sr 6 i 8 9 unit of blood pressure voice volume memory deletion language SJ o Sr The meter will automatically turn off when the setting is complete For memory deletion please refer to the Owner s Manual for details 2 Set the Lancing Device Pull off the cap of the lancing Insert a lancet into the lancet device holder and push down firmly until it is fully secured amp amp Twist the protective disk off the Replace the cap by aligning lancet the arrow on the cap with the release button 2 5 2 6 Select the depth of penetration by turning the adjustable tip in either direction so that the color change inside the arrow on the cap points to the release button when it is desired depth ready Pull the cocking control back until it clicks You will see a Lancing device lancets and clear cap may not be included If your lancing device dif
3. de memoria 9 Lenguaje L1 Ingl s L2 Espa ol El medidor se apagar autom ticamente cuando la programaci n est completa Para borrar la memoria por favor revise el Manual del Usuario para obtener mayores detalles Si ntese al menos 10 minutos antes de realizar la medici n Arregle los tubos de aire para que queden encima de las principales arterias de su brazo Presione i 5 Haciendo una Prueba de la Presi n Arterial Estire su brazo izquierdo con la palma hacia arriba Deslice la banda de presi n en su brazo izquierdo un poco m s arriba del codo La l nea roja en el borde de la banda de presi n debe estar aproximadamente de 0 8 a 1 2 pulgadas de 2 a 3 cm m s arriba de su codo Rel jese y aseg rese de que la banda est a la misma altura que su coraz n 2 Preparando el Dispositivo de Punci n Desprenda el casquillo del dispositivo de punci n Gire el disco protector hasta que se separe de la lanceta Seleccione el nivel de penetraci n girando la punta ajustable en cualquier direcci n hasta que la flecha en el casquillo le indicaque la profundidad deseada Inserte la lanceta en el adaptador y emp jela firmemente hasta que est totalmente asegurada Remplace la tapa aline ndola con la fecha del casquillo y con el bot n de expulsi n gt Empuje el control de montaje hacia atr s hasta que haga un click Ver que el color
4. CA 91320 USA Productos hecho en Taiwan N mero de Tel fono Gratuito 1 888 307 8188 3 30am 5 00pm N Lunes a Viernes 1 866 469 2632 24 Horas 7 Dias a la semana www foracare com usa 315 3252000 004 Estimado Usuario del Sistema FORA D30 Gracias por adquirir el Sistema de Vigilancia de Glucosa y Medidor de Presi n Arterial FORA D30 para controlar su diabetes Al ser un aparato para ser utilizado en el hogar este sistema le ayudar a vigilar sus niveles de glucosa en la sangre as como su presi n arterial La Gu a de Referencia R pida le asistir para programar su sistema y examinar los niveles de glucosa en la sangre Para obtener la informaci n completa sobre este sistema y sus caracter sticas por favor revise el manual del usuario Probando la Soluci n de Tira Reactivas Tira Reactiva Control e e Lancetas Para obtener muestra de sangre de otras partes que no sea la Casquillo Claro yema del dedo Por favor notar Utilice solamente las tiras reactivas FORA D30 con el medidor FORA D30 Punta ajustable an Indicador de profundidad Flecha Eyectar Control de expulsi n mo Bot n de liberaci n Vista frontal del medidor Ranura de Prueba Bot n Arriba Abaj Luz de Indicaci n de BT Expulsi n de la Tira Reactiva Banda de Presi n pedia 3 Puerto de Datos p Para FORA D30e Bot n S i 7 Puerto para los Audifonos Bot n M Puert
5. cambiar dentro del bot n de expulsi n cuando est listo El dispositivo de punci n las lancetas la casquillo claro podr an no estar incluidas en su equipo Si su dispositivo de punci n difiere del mostrado aqui por favor dir jase al Manual del Usuario para asegurarse de hacer el uso debido del mismo 5 5 IES H A gt Medici n en progreso Inicio de inflado Cuando la banda de presi n tiene suficiente aire se detendr La banda de presi n se desinflar continuamente 5 6 ggs rch SYS IL m mmHg 7 mp DIA Je El monitor mostrar la presi n sist lica la presi n diast lica y el pulso as como la fecha y la hora Presione para apagarlo
6. fers from the one shown here please refer to the manufacturer s manual to ensure proper usage 3 1 Y Tear off the security label Wash and dry your hands Tamper Seal When opening thoroughly Take a test strip the vial for the first time record out and then close the vial the date on the label tightly Gently squeeze around the punctured area to obtain enough blood While 4 is flashing on the display hold and touch the absorbent hole of the test strip to the drop of blood until the confirmation window is completely filled AJ ao aom After the monitor counts down to O your test result will appear along with the date and time and will be automatically stored in the memory Insert a test strip to turn on the monitor The sequences of LCD display are lt s flashing 4 with date and time Take the pre set lancing device Hold the lancing device firmly against the puncture site Press the release button to obtain a drop of blood Remove the used test strip Dispose of the used strip and lancet carefully For testing with control solution please refer to the Owner s Manual for detailed information Your result will display the following messages Appears Lo lt 20 mg dL 1 1 mmol L KETONE gt 240 mg dL 13 3 mmol L UN gt 600 mg dL 33 3 mmol L When glucose Reference values for blood glucose Time of day Normal p
7. i n de control por favor dir jase al Manual del Usuario para obtener mayor informaci n 4 Leyendo sus Resultados Su resultado mostrar los siguientes mensajes Aparecera Cuando la glucosa Lo lt 20 mg dL 1 1 mmol L KETONE gt 240 mg dL 13 3 mmol L tt gt 600 mg dL 33 3 mmol L Referencias del valor de la glucosa en la sangre Hora del d a Rango normal para el plasma en la glucosa para personas sin diabetes En ayuno o antes de la comida lt 100 mg dL 5 6 mmol L 2 horas despu s de la comida lt 140 mg dL 7 8 mmol L Fuente Asociaci n Americana contra la Diabetes 2008 Recomendaciones Practicas Cl nica Cuidados de Diabetes Supplemento 1 S1 108 Por favor consulte con su doctor para determinar cual es el rango meta que m s conveniente para usted 1 Programando el Medidor a ff LA gt Em Presione S para comenzar la programaci n La luz del a o parpadear primero Presione hi para cambiar los valores Presione J aumentar los n mero m s rapidamente Presione Programaci n para seguir con el pr ximo paso IT PM mmHg KPa La Fecha se iluminar Siga Para hacer los cambios La secuencia para la programaci n ser 1 Fecha 2 Formato de hora 3 Hora 4 5 Unidad de medida de la glucosa Unidad de Temperatura 6 Unidad de medida de la presi n 7 Volumen de la voz 8 Borrado
8. lasma glucose range for people without diabetes Fasting and before meal lt 100 mg dL 5 6 mmol L 2 hours after meals lt 140 mg dL 7 8 mmol L Source American Diabetes Association 2008 Clinical Practice Recommendations Diabetes Care 31 Supplement 1 S1 108 Please work with your doctor to determine a target range that works best for you 5 Test Your Blood Pressure Sit down for at least 10 minutes before measuring Arrange tubing over the main arteries inside of your arm Press O Stretch your left arm forward with your palm facing up Slide the cuff onto your left arm above your elbow The red line on the edge of the cuff should be approximately 0 8 to 1 2 inch 2 to 3 cm above your elbow Relax and make sure the cuff is at the same height as your heart E oo Y 5 6 gg pam a ico 16 v Measurement is in progress Start inflation Stop inflation when cuff pressure is enough Cuff pressure deflates steadily The monitor will display the systolic pressure diastolic pressure and heart rate along with the date and time Press O to switch off i D30 SISTEMA DE VIGILANCIA DE GLUCOSA Y MEDIDOR DE PRESION ARTERIAL Guia de Referencia Rapida Para autoan lisis Lea las instrucciones antes de utilizarse Para uso diagn stico in vitro Distribuido por Fora Care Fora Care Inc 810 Lawrence Dr Suite 104 Newbury Park
9. o Adapatador Para la Bot n ON OFF Corriente Alterna CA Visualizaci n de Pantalla Vista de la parte trasera del medidor Compartimiento de la Bater a Covertor de la Bater a 3 Haciendo una Prueba de Glucosa en la Sangre Desprenda el sello de seguridad Sellado para certificar su autencidad Al abrir el frasco de las tiras por primera vez escriba la fecha en el envase b Y Inserte una tira reactiva para encender su monitor La secuencia que aparecer en el LCD ser parpadeando 4 con la fecha y la hora L vese y s quese bien las manos Saque una tira reactiva y aseg rese de cerrar bien el envase Tome el dispositivo de punci n preparado anteriormente Sostenga el dispositivo firmemente contra el lugar de punci n Presione y libere el bot n para obtener una gota de sangre Gentilmente apriete el rea alrededor del lugar de punci n para obtener suficiente sangre El medidor contar de manera regresiva hasta O el resultado aparecer junto con la fecha y la hora y ser almacenado autom ticamente en memoria EAN a Y Mientras 4 est parpadeando en pantalla aplique la gota de sangre en el canal absorbente de la tira reactiva hasta que la ventana de confirmaci n est completamente llena Saque la tira reactiva usada Descarte la tira y la lanceta con mucho cuidado Para hacer una prueba con la soluc
Download Pdf Manuals
Related Search
Related Contents
Classic Accessories 72982 Instructions / Assembly CUDA-GDB Samsung RSG5DUMH Εγχειρίδιο χρήσης Copyright © All rights reserved.
Failed to retrieve file