Home
Instruction Manual
Contents
1. Specifications Model No BPC 81U Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure 20 280mmHg Pulse 40 190 minute Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Memory capacity 80 sets memories 80x1 user Inflation Automatic inflation by air pump Deflation Automatic liner pressure deflation valve Pressure Release Automatic exhaust valve Sensor Semiconductor pressure sensor Power Supply 6V DC 4 AA alkaline batteries Measuring Interval 1 mmHg Operating Temperature Humidity 10 C 40 C 50 F 104 F 40 85 R H maximum Storage Temperature Humidity 20 C 50 C 4 F 122 F 15 90 R H maximum Battery Life Alkaline batteries Approx 250 uses It is estimated on the premise that backlight hasn t been enabled Unit Weight Approx 400grams not including batteries Cuff Circumference Fits arm circumference 8 7 12 6 Unit dimensions Approx 115 I x 125 w x 50 h mm Accessories Storage Case Instruction Manual 4 AA alkaline batteries Specifications are subjected to change 30 Warranty Information Your product MEDRON BPC 81U Blood Pressure Monitor is guaranteed to be free from defects in workmanship and materials under normal use for a period o
2. Automatic Blood Pressure Monitor WIP PC LINK LEDS indicators or Arm a 25 Maintenance Storage 1 Always put the device in the storage box attached when not in use or during transporting 2 If you won t use the device for an extended period like over 3 months remove the batteries 3 Do not store the device under direct sunlight high temperature humid dusty or corrosive environment 4 Do not stretch bend or tug the wrist cuff too hard 5 Do not wet the unit Cleaning 1 Do not use an alcoholic base benzene gasoline or solvent agent to clean the device 2 Wipe with a moistened cloth with clean water or a mild cleaning agent and then dry the device with a soft and dry cloth 3 The dirt on the cuff can be wiped by the moistened cloth and soap 4 Do not flush the device and cuff 5 Do not bend the cuff or sleeve and wrap the sleeve to the inside out surface 6 Do not disassemble the device or dismantle the cuff or try to repair by yourself If any problem happens bring the device to the distributor for further examination 7 Do not operate the device under the severe environment of extreme temperature or humidity or direct sunshine Error Message amp Troubleshooting The unit is manufactured through the complete quality assurance system If the measurement is not made correctly the following error will be displayed Measure your blood pressure again correctly 26 ERROR MESSAGES
3. If you have any problems with the device please notify the distributor within the warranty period with Model no Serial no The actual problem Quantity of the devices Distributor MEDRON INC 705 Summerfield Dr Murphy TX 75094 U S A Tel 1 972 836 0975 Email support medronhealth com 35 Manual de Instrucciones Monitor autom tico de presi n arterial con PC Link e indicadores LED para el brazo gcs o BPC 81U 36 INtrOAUCCI N eee ene 39 Las se ales de advertencia y declaraciones de Seguridad coi ii 40 Salud y valores de presi n arterial 0ssc0 41 Qu es la presi n arterial ooooooonncccnnncconnnccnnnscnnnnnns 41 Informaci n importante c oocccncccnnnnononcnnnnnnnnenanenasanannnnnns 43 Precauciones cccsssceeseserenscceesssceesesensenenenenenscceeesenses 43 Contraindicaciones sccseccesseeseeeesseeseeseeeneneessenes 44 AQUVertenCia c cooomncconncccnnnnnncnnnnncnnnnanon nn nan cn iseina inaani n 45 Sugerencias antes de medir la presi n arterial 45 Descripciones del diSpositiVO cooomcccnnniccnnnnacnnnaanno 46 Descripci n de los botones de control m 47 Descripci n de los S mbolos en la pantalla LCD 47 Adaptador o Instalando Remplazando Baterias 39 La unidad se puede utilizar con el adaptador o con DAMAS iii cidad 39 Instalando Remplazando Bater as ssseee 39 37 P
4. dico 58 Error Causa Como corregir Mon Date Hour Min 19 904 130 DD i i 2a 8 Err No se detecto presi n arterial o el pulso Postura incorrecta durante la medici n Banda no se ajusto La banda no se ajusto bien por favor ajuste de nuevo siguiendo las instrucciones Espere por lo correctamente menos 3 minutos antes de tomar otra medici n Repita los pasos incluidos en C mo tomar una medici n en pagina 15 e Inflaci n La banda no se insuficiente o falla ajusto bien por Mon Date Hour Min r 2 10 01 12 08 de inflaci n favor ajuste de manure u e gt 0 Banda nuevo siguiendo 3 descompuesta las instrucciones Err Falla en la bomba O la v lvula de ventilaci n o las v lvulas de desinflar por favor comun quese con el distribuidor Si un problema se produce mientras se est utilizando el monitor de presi n arterial consulte el documento adjunto Soluci n de problemas en primer lugar Si usted no puede medir su presi n arterial correctamente despu s de tomar las medidas indicadas el monitor puede estar descompuesto Por favor env e la unidad al distribuidor para su reparaci n No desarme ni intente reparar el monitor usted mismo 59 SOLUCION DE PROBLEMAS Condicion Causa Correccion Despu s de instalar Baterfas no Comprobar y las bater as est n instaladas corregir la ninguna indicaci n o correctamen
5. 25 from the ETTI average of all heartbeat Irregular Heartbeat intervals while the unit is TH Short Long measuring the systolic Blood pressure RANJA and diastolic blood pressure If such an irregular rhythm is detected more than twice during measurement the irregular heartbeat symbol appears on the display with measurement results What is Arrhythmia A heartbeat is stimulated by electrical signals that cause the heart to contract Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio electrical system that drives the heartbeat Typical symptoms are skipped heartbeats premature contraction an abnormally rapid tachycardia or slow bradycardia pulse This can be caused by heart disease aging physical predisposition stress lack of sleep fatigue etc Arrhythmia can only be diagnosed by a doctor through a special examination 17 Whether the appearance of the irregular heartbeat symbol in the results indicates arrhythmia or not can only be determined by an examination and diagnosis by your doctor Note If the irregular heartbeat symbol is shown frequently please make your doctor aware of it Conducting self diagnosis and treatment based on measurement results are dangerous Be sure to follow the instructions of your doctor How to Use the Memory Features The blood pressure and pulse measured and displayed are automatically stored in the memory The blood pressure monitor can
6. 90 R H Sugerencias antes de medir la presi n arterial 1 Por favor rel jese f sica y mentalmente por lo menos 5 10 minutos antes de la medici n 2 Evite comer fumar hacer ejercicio ba arse y beber alcohol y caf t durante al menos 20 30 minutos antes 3 de medir su presi n arterial 4 Aseg rese que la banda se encuentre al mismo nivel que su coraz n 5 El estr s aumenta la presi n arterial Mantenga calma 45 durante la medici n Por favor no hable durante la medici n Evite orinar o defecar antes de tomar una medida 8 Espere por lo menos 3 minutos antes de tomar otra medida de la presi n arterial 9 Mantenga registros de mediciones para su m dico como referencia Una medida no puede concluir la salud de su presi n arterial resultados de mediciones a largo plazo revelar n la tendencia de su presi n arterial Trate de medir su presi n arterial a la misma hora cada d a para mantener consistencia en las mediciones no Descripciones del dispositivo LCD DISPLAY W MEMO A BUTTON y HH SCAN Y BUTTON gt TIME BUTTON A POWER BUTTON START BUTTON 4 SPEAKER AIR JACK RY AA 1 5V x4 Air Plug Connects to the air jack Arm Cuff Air Tube Green Cuff Marker STORAGE BAG 46 Descripci n de los botones de control e POWER Para activar o desactivar la unidad e START Inicio para i
7. Delete all measurements Turned off the unit first then keep pressing SCAN W until dEL ALL displayed Press SCAN W button again and all memories will be deleted when 00 ALL shown on the screen JEL oo ALL ALL mM mM 19 HealthPlus Software Installation and User Manual Please check http www medronhealth com products BPC 81U docs latest for latest updates on the software manual 1 Installation 1 1 Software Installation Application Install Security Warning A Publisher cannot be verified Are you sure you want to install this application l Name HealthPlus i I From Hover over the string below to see the full domain CiUsersiOksanalDocumentsimedron swiHealthPlus_Deploy0 0 2 f Publisher Unknown Publisher a Coonan While applications can be useful they can potentially harm your computer If you do not trust the source do not install this software More Information Download latest version of Medron HealthPlus software from http www medronhealth com products healthplus software latest Unzip it to known location on your computer Double click setup exe file in unzipped folder Please make sure computer is connected to Internet It shall open Application Install dialog box Click Install button as shown in the picture below Follow instructions that will come up on your screen Installation concludes with starting of HealthPlus
8. Error Indicators Cause How to correct Date Hour Min 6 ncorrect posture or talks during measurement Cuff is not fastened well OWait at least 3 10 11 12 38 1 OThere are any minutes before t artificial taking another E ce interference and measurement noise during User has special measurement characteristic User is tense and does not relax or has severe heart beat problem Mon Date How min No pulse or blood Cuff is not fastened ie Be pressure sensed correctly or not tight o eIncorrect posture enough Ex during mrs measurement Cuff is not wrapped properly Mons Dite e500 e Insufficient or eCuffis not fastened oes A failure inflation well please 3 e Cuff broken re fasten the cuff Es is Pump or venting er valve or deflation valve failure please contact the distributor 27 If a trouble occurs while you are using the blood pressure monitor check the attached Troubleshooting first If you can not measure your blood pressure correctly even after taking the following countermeasures the monitor may be broken Please send the unit to the distributor for repair Do not dismantle or try to repair the monitor by yourself TROUBLESHOOTING Condition Cause Correction After the batteries are e Batteries are not Check and correct installed no installed properly the battery indication or symbol Batteries run out polarities displayed on the the elect
9. Range Hg Hg Borderline Low 30 Bo blood Pressure 60 40 Too Low Blood Pressure Dangerously 50 33 Low Blood Pressure Source for Tables on Page 32 amp 33 Disabled world com 32 BLOOD PRESSURE RANGE BY AGE Age 15 to 19 Systoli Diasto ic Range ic Range Age 20 to 24 Systoli Diasto c Range ic Range Age 25 to 29 Systoli Diasto c Range ic Range Age 30 to 34 Systoli Diasto c Range ic Range Age 35 to 39 Systoli Diasto Systoli Diasto Systoli Diasto Systoli Diasto Systoli Diasto Systoli Diasto c Range ic Range Age 40 to 44 c Range ic Range Age 45 to 49 c Range ic Range Age 50 to 54 c Range ic Range Age 55 to 59 c Range ic Range Age 60 to 64 c Range ic Range Min 105 73 Min 108 75 Min 109 76 Min 110 77 Min 111 78 Min 112 79 Min 115 80 Min 116 81 Min 118 82 Min 121 83 33 Average 117 77 Average 120 79 Average 121 80 Average 122 81 Average 123 82 Average 125 83 Average 127 84 Average 129 85 Average 131 86 Average 134 87 Max 120 81 Max 132 83 Max 133 84 Max 134 85 Max 135 86 Max 137 87 Max 139 88 Max 142 89 Max 144 90 Max 147 91 PERSONAL BLOOD PRESSURE S RECORD Name Age Weight Date Time SYS DIA PULSE Remark 34 Customer Complain Method
10. application HealthPlus application is also accessible by following Start gt Programs gt Medron gt HealthPlus HealthPlus installation performs following tasks transparent to user Installs NET 4 x if computer does not have it already This task 20 may take up to 12 minutes in case NET is not installed on the computer Please ensure that computer is connected to the internet e Installs driver for the device for Windows8 Windows7 and WindowsXP e Installs application 2 User Operations 2 1 Settings In this view you can assign names and nicknames for two users Simply double click on any fields and type in the name DOB gender info A unique user id is automatically assigned for each user 2 2 Syne Click on Sync Button and follow onscreen directions Ensure that you click on Ignore duplicate entries box to ensure that entries from Medron Blood pressure unit are not duplicated whenever 21 you sync again ep 1 Please daconeast and connect beck U38 sabi of BF Monitor to PC ing 2 Prac PC Syme on Minden Seed rennara Manta 22 2 3 Readings Tabular representation of Systolic Diastolic readings with time stamp date information 2 3 1 Add a new reading This feature allows you to add a reading manually You can add a new reading by double clicking the last row that is empty No data in that row This will pre populate all fields of this row with fixed set of values Double click o
11. de colores para indicar presi n normal verde presi n alta amarillo o presi n anormal alta rojo Opcional Banda de brazo adecuada para los tama os de brazo 39 8 7 a 12 6 Apagado autom tico despu s de 1 minuto Indicador de bater a baja y detecci n inteligente de error Requiere cuatro bater as alcalinas AA Funciones de Recordar Recall y de escaneo Scan Borrar una o todas las mediciones Las se ales de advertencia y declaraciones de seguridad A ATENCI N Lea el manual del usuario antes de usar x Tipo BF 40 Salud y valores de presion arterial La presi n arterial del cuerpo humano inclina a aumentar naturalmente despu s de la mediana edad Este s ntoma se debe al continuo envejecimiento de los vasos sangu neos Otras causas como la obesidad la falta de ejercicio el colesterol LDL que se adhiere a los vasos sangu neos causan el mismo s ntoma y hacen que los vasos sangu neos pierdan su elasticidad Presi n arterial alta acelera el endurecimiento de las arterias y el cuerpo se vuelve m s susceptible a la enfermedad cardiaca coronaria y apoplej a Por esta raz n es que necesitamos saber la tendencia de la presi n arterial de rutina con el fin de ver si nuestra condici n f sica es saludable o no La presi n arterial fluct a constantemente a lo largo de nuestra vida diaria y es un elemento esencial para nuestra gesti n diaria de la salud Qu es la presi n art
12. puede deberse a los diferentes ambientes O La presi n arterial est cambiando de acuerdo con el estado fisiol gico o psicol gico del cuerpo humano Especificaciones Model No BPC 81U Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure 20 280mmHg Pulse 40 190 minute Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Memory capacity 80 sets memories 80x1 user Inflation Automatic inflation by air pump Deflation Automatic liner pressure deflation valve Pressure Release Automatic exhaust valve Sensor Semiconductor pressure sensor Power Supply 6V DC 4 AA alkaline batteries Measuring Interval 1 mmHg Operating Temperature Humidity 10 C 40 C 50 F 104 F 40 85 R H maximum Storage Temperature Humidity 20 C 50 C 4 F 122 F 15 90 R H maximum Battery Life Alkaline batteries Approx 250 uses It is estimated on the premise that backlight is not enabled Unit Weight Approx 400grams not including bteries Cuff Circumference Fits arm circumference 8 7 12 6 Unit dimensions Approx 115 I x 125 w x 50 h mm Accessories Storage Case Instruction Manual 4 AA alkaline batteries Especificaciones pueden cambiar sin previo aviso 62 Informacion s
13. store up to 80 measurements If more than 80 measurements have been taken the earliest measurement will be erased and replaced by the most recent measurement 1 Review the Average Value and previously measurements Press MEMO A button the unit first display the average values of Systolic Diastolic and Pulse Averaged from all memorized readings Press MEMO A button again to review the measurement from the latest to the earliest 2 The latest measurement M 01 appears when you press MEMO A button M 01 is the latest reading measured The Systolic Diastolic Pulse and Date Time of the measurement will be displayed Press MEMO A button to repeatedly review other memorized readings The 18 readings will be displayed as M 02 M 03 M 04 etc You can press SCAN W button to switch to the automatic display mode 3 Scan all previous measurements Press SCAN Y button the unit will display all measurements one by one in one in one second interval You can press MEMO A button to switch to the single display mode 4 The 3 colors LED warning lights It will indicate the status of each blood pressure measurement is Normal green Higher yellow or Abnormal High reddish How to delete Single or All Memories 1 Delete single measurement You can delete the single memory just after taking the measurement Press SCAN W button then dEL will appear and flash Press SCAN W button again to confirm the delete function 2
14. Instruction Manual Automatic Blood Pressure Monitor with PC LINK LEDs indicators for Arm V2 1 BPC 81U INTTOUCt ION ooocccnncccnnnancnonananonanaconnnanc cnn nan cr aaa eran c rro 4 Warning Signs amp Safety Statements ooonococonicconannnonanos 4 Health and Blood Pressure Values ooomocconncccnnnaccnonannno 4 Warning iosocasionaracacansococnaoconinn nono rn ranniandna ira nabdnan and nadanectanes 5 Suggestions before Measuring Blood Pressure 5 Device DescriptiONS oommconnncnnnnscnnnnncncnanaccnnnananannac cnn 7 Description of Control Buttons oooonncccnonoccnanacnnnnnnnnens 8 Description of LCD Display Symbols seseseesees 8 Installing Replacing Batteries ooonnncconncccnonaccnnnannnnnannnos 9 Program Date and Time ooocoonncccnnocccnnnncncnnnancnnanacnnnzncanos 11 How to Apply the Arm Cuff sscesesseneseerseesseeeseeenes 12 Correct Measurement Position sccseeseeeeeeeeeenes 14 Measurement while sitting down cssseseseeeeeee 14 How to Take A Measurement scccsseeessseesesteeeeee 14 How to SEND MEASUREMENTS TO PC nsss 16 What is Irregular Heartbeat cscceseeseeseeneneeeseees 17 What is Arrhythmia ccccescsseesseesseeeeseeeseneneeeessenes 17 How to Use the Memory Features cssssssseeeees 18 2 How to delete Single or All Memories 0 0 19 HealthPlus Software Installation and User Manual 20
15. Maintenance onccconncccnnnnnccnnnnnnnnnnnconanna con nnnncrnnnane nana nr anna 26 Error Message amp Troubleshooting ococommccnnnnncnnnoanoo 26 TROUBLESHOOTlNGocccocncccnococnccncnnnnnnnasncnnnanenannrnncnnnanes 28 Spe cificatio Sise a a td 30 Warranty Information ccccssseeessseeeesssteeessneeeesseees 31 Introduction Thank you for purchasing the Medron BPC 81U Automatic Blood Pressure Monitor with LEDs for Arm For your safety please be sure to read this Instruction Manual thoroughly before using the Blood Pressure Monitor For other specific information about your own blood pressure CONTACT YOUR PHYSICIAN Warning Signs amp Safety Statements AN ATTENTION Read user s manual before use Type BF applied part Health and Blood Pressure Values Classification of Blood Pressure by the WHO The World Health Organization WHO and the Inter national Society of Hypertension ISH developed the Blood Pressure Classification shown as below Systolic blood pressure mmHg Moderate hypertension Mild hypertension Optimal blood pressure Diastolic blood pressure 80 85 90 100 110 According to the blood pressure classification by the WHO ISH revised in 1999 Warning If the event of the cuff pumping up and not stopping please open the cuff at once Do not measure repeatedly for a long period of time This device is not supposed to be used if your wrist has any wound or injury If locks conne
16. OVEOrIeNCIA Re eer ert 49 Programar fecha y hora ooonococncccononcccnnonanonanaccnnnaann canon 49 C mo aplicar la banda para el brazo ooocoonnncccccnnnnnosnnss 50 Posici n correcta para la medici n oocococanicnnnninncnnn 51 Medici n mientras se est sentado seeeeeseeeeeees 51 C mo tomar una Medici n cooncconccnnnccnnnnnnnennnnenannnnnonos 52 C mo utilizar las funciones de memoria occccccnms 55 C mo borrar una o todas las memorias ooocccncnnnnnn 56 ManteniMientO ooonmncncnccccnnonnnnnnnacnnnnaaccnnnnaconanacc ra nacc ranas 57 Mensaje de error y soluci n de problemas 58 ESpecificacionesS ooonnncconncccnnncnnnnnanacnnnnnnccnanaco nana rnnnannna 62 Informaci n sobre la garant a csecseeseeeseeeeeeees 63 38 Introduccion Gracias por comprar el MEDRON BPC 81U Monitor de Presi n Arterial Autom tico con indicadores LED para el brazo Para su seguridad por favor aseg rese de leer este manual de instrucciones antes de utilizar el monitor de presi n arterial Para informaci n espec fica acerca de su propia presi n arterial consulte a su m dico Medidas de presi n arterial SYS y DIA y de pulso Sistema de medici n autom tico con inflaci n y deflaci n para proporcionar medici n de la presi n arterial en la conveniencia de su hogar La funci n de aviso de la voz dar a conocer el valor medido 80 grupos de memorias con fecha y hora 3 LED
17. ajar un dedo entre la banda y el brazo Posicion correcta para la medicion Es extremadamente importante para los valores medidos que la banda est al mismo nivel del coraz n Posici n m s alta o m s baja dar desviaciones del valor correcto Medici n mientras se est sentado TE Si ntese en una silla con los pies apoyados en el suelo y apoye el brazo sobre una mesa de modo que la 51 banda quede al mismo nivel que su corazon 2 Relaje el brazo y gire la palma hacia arriba 3 Aseg rese de que no haya torceduras en la manguera del aire 4 Despu s de respirar profundamente varias veces antes de la medici n tome un respiro natural y relaje su cuerpo C mo tomar una medici n Por favor lea y siga las instrucciones en la secci n de Sugerencias antes de medir la presi n arterial y C mo colocar la banda del brazo antes de tomar una medida Selecci n de usuario uno o dos Presione el bot n POWER para encender la unidad Todos los s mbolos aparecer n durante un par de segundos despu s el n mero 0 y el s mbolo de persona parpadea Entonces usted puede presionar A o Y para seleccionar el usuario 1 o 2 La unidad dice measurement ready listo para medir cuando el s mbolo deja de parpadear Si no selecciona ning n usuario espec fico el usuario seleccionado por omisi n es 1 52 Presione el bot n START la banda se infla autom ticamente a aproximadamente 170mmHg 50mmhg superior a la
18. ante un segundo y luego regresar al modo de espera 3 Vuelva a colocar la tapa de las bater as 48 Nota Cuando A Indicador de la bater a aparece en la pantalla las bater as est n bajas de carga el ctrica Advertencia a b Aseg rese de seguir las instrucciones anteriores para conectar adaptador y la instalaci n sustituci n de bater as Le recomendamos el uso de las bater as alcalinas para mejor funcionamiento y m s duraci n del dispositivo Utilice nicamente bater as nuevas del tama o requerido y NO mezclar usadas con nuevas o diferentes tipo de bater as Retire las bater as si no se usa el monitor de presi n sangu nea durante un per odo prolongado es decir 3 meses Las bater as pueden derramar qu micos y da ar las partes electr nicas Reemplace inmediatamente bater as agotadas con nuevas Revise las bater as peri dicamente y reempl celas cuando sea necesario Programar fecha y hora 1 Presione continuamente el bot n TIME durante 2 segundos hasta que aparezca 2006 en la pantalla y comience a parpadear 49 2 Presione MEMO A o SCAN Y para establecer el numero que representa el a o Usted puede mantener presionando MEMO A o SCAN Y durante unos 2 segundos el n mero del a o se mostrara a una velocidad m s r pida Presione el bot n TIME para confirmar el a o Entonces el n mero que representa la fecha parpadear De la misma manera se p
19. ate will flash In the same manner set the Month Date Hour and Minute Note After replacing batteries always check the Date Time is properly set or not first then use the blood pressure monitor If the batteries are removed for more than 40 11 seconds you must reset the Date Time How to Apply the Arm Cuff Pile Side Material Sewn Hook Material Insert the air plug of the arm cuff into the air jack of the blood pressure monitor The cuff should be assembled correctly when it is removed from the box If it is not pass the end of the cuff furthest from the tubing through the metal D ring to form a loop The smooth cloth should be on the inside of the cuff loop If the cuff is assembled correctly the sewn hook material will be on the outside of the cuff loop and the metal D ring will not touch your skin Put your left arm through the cuff loop The bottom of the 12 cuff should be approximately 1 2 above the elbow The cuff tubing should be positioned along the middle of the inside of your arm as shown Bottom Edge 1 2 Inch Cuff Tube Cuff Tab 1 Pull the cuff so that the top and bottom edges are tightened evenly around your arm 2 When the cuff is positioned correctly press the sewn hook material firmly against the pile side of the cuff 3 The cuff should be wrapped so that it fits snugly and stays in place You should be able to fit one finger between the cuff and your arm 13 Co
20. atteries are removed or unplug the adapter for more than 40 seconds the memories and the Date Time setting will be erased Then you must reset the Date Time Slide the battery compartment to remove it Place the batteries 4 AA Alkaline batteries in the compartment as indicated by the polarity symbols and marked inside All the display symbols appear for 3 seconds and then return to standby mode Replace the battery compartment cover Note When CA Low Battery indicator appears on the display the batteries are weak Change the batteries as soon as possible or it may not be able to take any measurement And the memories and the Date Time setting of the unit may be lost We recommend you to use the ALKALINE batteries for the best performance and the longest life Remove the batteries if not to use the blood pressure 10 monitor for an extended period i e 3 months The batteries can leak chemicals that can destroy electronic parts Immediately replace run down batteries with new ones Program Date and Time Continuously press TIME button for 2 seconds until 2006 shown on the screen and starts to flash Press MEMO A button or SCAN button to set the number representing the Year You can press and hold MEMO A or SCAN buttons for about 2 seconds the number of the Year will be displayed in the faster speed Press TIME button to confirm the Year setting Then the number representing the D
21. ctors are used in the construction of tubing there is a possibility that they might be inadvertently connected to intra vascular fluid systems which case may allow air to be pumped into a blood vessel Take batteries out of the housing if the unit is not to be used for a long time Do not use different type date or brand name batteries and this may lead to an incorrect reading Leaving the batteries in the blood pressure monitor for a long period and not using the device may damage the main unit Suggestions before Measuring Blood Pressure It is recommend that persons has one of the diseases as heart troubles kidney trouble hyper tension diabetes 5 arteriosclerosis or frustration problem of blood vessel please consult your physician before and during using the blood pressure monitor to determine if your wrist blood pressure accurately reflects your actual blood pressure Please sit or lie down for at least 5 10 minutes before taking a measurement Avoid eating smoking exercising bathing and drinking alcohol caffeine or tea for at least 20 30 minutes before taking a measurement and avoid talking during a measurement Be sure the wrist cuff is at the same level as your heart Stress raises blood pressure Keep calms and relax yourself during a measurement Wait 2 3 minutes before taking another blood pressure measurements Keep the records for your physician as reference Reminded that one measurement
22. de 55 visualizaci n autom tico no tiene la funci n del sistema de voz Usted puede presionar el bot n MEMO A para cambiar al modo mostrar una lectura 3 Los 3 colores LED de advertencia Indican el estado de cada medici n de la presi n arterial Normal verde Alta amarillo o Anormal Alta rojo C mo borrar una o todas las memoria Borrar una sola medici n Usted puede borrar la memoria justo despu s de tomar la medici n Presione SCAN Y y luego dEL aparecer y parpadeara Presione SCAN Y de nuevo para confirmar la funci n de borrar la memoria Borrar todas las mediciones Apague la unidad y luego mantenga presionado SCAN Y hasta que aparezca DEL ALL en la pantalla Presione SCAN Y de nuevo y todas las memorias se borran cuando 00 ALL se aparece en la pantalla wes rr wo es mrs FIL MILL mM mM 56 Mantenimiento Almacenamiento 2 3 Siempre coloque el dispositivo en la caja de almacenamiento cuando no est en uso o durante transportaci n Si no va a utilizar el dispositivo durante un per odo prolongado m s de 3 meses quite las bater as No guarde el dispositivo bajo la luz solar directa altas temperaturas humedad polvo o medio ambiente corrosivo 4 No estire doble ni jale de la banda demasiado duro 5 No moje la unidad Limpieza 1 No utilice alcohol benceno gasolina o agente disolvente para limpiar el dispositivo 2 Limpie con un pa o humedecido co
23. does not provide you with real blood pressure value only long term records will reveal the long term trend of your blood pressure Try to measure your blood pressure at the same time each day for consistency Device Descriptions LCD DISPLAY MEMO 4 BUTTON SCAN BUTTON TIME BUTTON POWER START BUTTON SEND BUTTON AIR JACK BATTERY AA 1 5V x4 Air Plug AA E Connects to the air jack Green Cuff Marker STORAGE BAG Description of Control Buttons POWER START To turn on or turn off the unit Start inflating to measure blood pressure and pulse e TIME To set the Date Time e MEMO A To review the measured record s manually To select the digit of Date Time e SCAN Y Automatically review all previously memorized record s To select the digit of Date Time To delete memorized record s PC SYNC To send data in memory to PC Press this button twice to send data to PC Description of LCD Display Symbols Date Time Mon Date Hour Min Blood 1G G 12 08 pressure nu Systolic ZZL unit A Stee mmHg ll 20 kPa Unit B Diastolic a oe Average Pressure T on g E j AER TA Person 1 2 Pulse 5 ny M_ Low Batter AR V ow Battery It Il m ag Memory e Symbol Installing Replacing Batteries You can use the unit by using Batteries Be sure the unit turned off before installing replacing batteries or the memories amp Date Time setting will be erased If the b
24. erial La sangre se bombea a las arterias por el latido contracci n y expansi n de una bomba llamada coraz n La presi n de salida de la sangre bombeada se llama presi n arterial La presi n arterial se agita con cada latido del coraz n El aumento de la presi n cuando el coraz n se contraiga se llama la presi n sist lica y la presi n baja cuando el coraz n se expande se llaman la presi n diast lica La presi n arterial es m s baja por la ma ana y aumenta de tarde a la noche Es m s baja en verano y m s alta en el invierno La presi n arterial var a naturalmente de vez en cuando durante el d a Son muchos los factores que pueden causar la fluctuaci n de la presi n arterial respiraci n ejercicio estr s mental el fumar preocupaci n comida medio ambiente 41 y o cambio de temperatura la hora del d a micci n y defecaci n conversaci n tomar un ba o beber alcohol medicamento y la actividad f sica etc Variaciones en la presi n arterial Variaciones en la presi n arterial durante el d a con mediciones tomadas cada cinco minutos como se muestra a continuaci n 1604 mmHg Systolic 140 pressure 120 100 80 Diastolic pressure e Clasificaci n de la presi n arterial por la OMS La Organizaci n Mundial de la Salud OMS y la Sociedad Internacional de Hipertensi n SIH han desarrollado una clasificaci n de la presi n arterial como se muestra abajo Systolic blood
25. f 4 years from the date of purchase For repair within four year warranty our Authorized Service Agent must be advised the defects of the device This warranty covers parts and labor only under normal usage any transportation cost and freight incurred will be at the owner s expenses Any defect from natural causes e g flood hurricane etc is not within this warranty This warranty does not cover damage incurred by usage NOT following the instructions accidental damage or being tampered with or serviced by unauthorized Service Agents Monitor subjected to misuse abuse negligence of the instruction manual unauthorized repair or modifications will waive the warranty The warranty excludes expendables and consumables like batteries All warranty claims must be directed to the distributor for the sale of the device The content of this warranty is subject to change without further notice 31 BLOOD PRESSURE CHART High Blood Pressure Range Systolic Diastolic Stages of High pressure mm pressure mm Blood Pressure Hg Hg 210 120 Stage 4 180 110 Stage 3 160 100 Stage 2 140 90 Stage 1 Normal Blood Pressure Range Systolic Diastolic pressure m pressure mm Pressure Range m Hg Hg High Normal 130 83 Blood Pressure Normal Blood ten 80 Pressure 110 75 Low Normal Blood Pressure Low Blood Pressure Range Systolic Diastolic pressure mm pressure mm Pressure
26. media de presi n arterial sist lica Cuando la banda alcanza el nivel de inflado correcto comienza a desinflarse autom ticamente y el n mero disminuye en la pantalla El s mbolo del corazon parpadea Si durante el desinflado el monitor encuentra que la presi n a Mon Date Hour Min Mon Date Hour Min Mon Date Hour Min 10 01 12 08 10 01 12 00 10 81 10 00 MZ Mirmo 1 a mmHg TEN a aE lai bo E a rn 2 O 19 0 medir es m s alta el dispositivo dejar de desinflarse y volver a inflarse para alcanzar la presi n viable hasta el m ximo 280 mmHg Si la inflaci n contin a y no se detiene favor de desatar la banda inmediatamente o apagu la unidad presionando el bot n POWER El monitor deja escapar el aire residual cuando la medici n se ha completado El s mbolo del coraz n O deja de parpadear y la presi n arterial y el pulso aparecer en la pantalla La unidad anuncia los valores medidos para sist lica diast lica y pulso Despu s de tomar la medida las ltimas lecturas se mostrar n en la pantalla antes de que se apagu el monitor Notas O Si quiere tomar otra medida espere al menos 3 minutos La espera permite que sus vasos sangu neos se recuperen a su estado normal M s tiempo de descanso puede ser necesario dependiendo de sus condiciones fisiol gicas Al encender la unidad dar un mensaje de voz Si usted no 53 E lo necesita apague el mensaje _Qu es el latido irregular del coraz
27. n Un latido irregular del coraz n se define como un latido que var a en Normal Heartbeat A Pulse A A un 25 del promedio de todos los A Blood pressure SSI intervalos de el latido del coraz n i a Irregular Heartbeat cuando la unidad intervalos Ev Short Long mientras la unidad est midiendo y lood pressure AIK S N la presi n arterial Si un ritmo irregular es detectado m s de dos veces durante la medici n el s mbolo de latido irregular del coraz n aparece en la pantalla con los resultados de medici n Qu es la arritmia Un latido del coraz n es estimulado por se ales el ctricas que hacen que el coraz n se contraiga Arritmia s lo puede ser diagnosticado por un m dico a trav s de un examen especial La arritmia es una condici n en la que el ritmo card aco es anormal debido a fallas en el sistema bio el ctrico que acciona el latido del coraz n Los s ntomas t picos son latidos card acos omitidos la contracci n prematura un anormalmente r pida taquicardia o bradicardia pulso lento Esto puede ser causado por enfermedades del coraz n el envejecimiento la predisposici n f sica el estr s la falta de sue o fatiga etc Si la aparici n del s mbolo de latido irregular del coraz n de los resultados indica arritmia o no esta s lo puede ser determinada por un examen y el diagn stico de su m dico Nota 54 Si el s mbolo de latido irregular del coraz n se muestra co
28. n frecuencia por favor comun queselo a su m dico El auto diagn stico y el tratamiento basado en los resultados de medici n son peligrosos Aseg rese de seguir las instrucciones de su doctor C mo utilizar las funciones de memoria La presi n arterial y el pulso medidos se almacenan autom ticamente en la memoria El monitor de la presi n arterial puede almacenar hasta 80 mediciones Si m s de 80 mediciones se han tomado las primeras mediciones ser n borradas y ser n reemplazadas con las mediciones m s recientes 1 Revisar el valor promedio y las medidas previas Presione MEMO A y la unidad mostrara de los valores promedios de las presiones sist lica y diast lica y pulso con mensaje de voz Valor promedio de todas las lecturas en memoria Presione el bot n MEMO A otra vez para revisar las mediciones desde la ltima hasta las primeras con mensaje de voz del sistema La ltima medici n M 01 aparece al presionar el bot n MEMO 1 A M 01 es la ltima lectura Las presiones sist lica y diast lica pulso y Fecha Hora de la medici n aparecer n en la pantalla Presione MEMO A para revisar varias otras lecturas de memoria Las lecturas se muestran como M 02 M 03 M 04 etc Usted puede presionar SCAN Y para cambiar al modo de presentaci n autom tico 2 Escanear todas las mediciones anteriores Presione SCAN Y la unidad mostrar todas las mediciones de una en una en intervalos de un segundo El modo
29. n agua limpia o un agente limpiador suave luego seque el dispositivo con un pa o suave y seco 3 La suciedad en la banda puede ser limpiado con un pa o humedecido y jab n 4 No lave el aparato y la banda 5 No doble la banda ni voltee la superficie interior hacia el exterior 6 No desarme el dispositivo o la banda o trate de repararlo usted mismo Si ocurre cualquier problema lleve el dispositivo al distribuidor para un examen m s detenido 7 No utilice el dispositivo en medio ambiente severo de temperaturas extremas humedad o luz directa del sol 57 Mensaje de error y soluci n de problemas La unidad ha sido fabricada mediante un sistema de control de la calidad Si la medici n no se realiza correctamente el error siguiente aparecer Mida la presi n arterial de nuevo correctamente MENSAJE DE ERROR Error Causa Como corregir Postura incorrecta 6La banda no se en la medici n o el ajusto bien por Mon Date Hour Min z o 3 10 0 1 12 08 Usuario se movi o favor ajuste de A hablo durante la nuevo siguiendo medici n las instrucciones Er O Hay interferencia Espere por lo y ruido durante la medici n El usuario est tenso y no se relaja o tiene problema de latido card aco severo menos 3 minutos antes de tomar otra medici n Repita los pasos incluidos en C mo tomar una medici n El usuario tiene caracter sticas especiales por favor consulte a su m
30. n each field to modify it 2 3 2 Edit an existing reading This feature allows you to edit an existing reading Double click the left mouse button on the desired cell of any row reading to edit the data in that cell 2 3 3 Deleting a reading This feature allows you to delete any single row by pressing Delete button on the right end of the row It also allows deletion of multiple rows by selecting multiple rows and then pressing delete key on the keyboard 23 2 4 Charts Graphical representation of Systolic Diastolic and Pulse readings plotted over time You can zoom in and zoom out using your mouse scroll bar Scroll down to view graphical plot of pulse information 10 23 2012 2 03 28 PM o Heart Pulso Chart 2 5 My Diary My Diary allows user to document daily notes about general health fitness or almost any thing that would be good for Physician to know during next visit 24 2 6 Report This view allows user to print the report Report includes all readings systolic diastolic pulse reading charts user name and relevant details needed for your physician It supports Print Report as well as Save to Excel xlsx features 2 7 Help Help view has all manuals including Quick start guide software installation instructional manual user manual support tickets form FAQ an de E mc Maen Soma Worl 5A gr Te astro e ASA Instruction Manual
31. n signals Hour Min Mon Date Hour Min n Dat Hour Min Mon M e Date 10 01 12 00 0 01 1000 10 80 1 12 00 MZ amg 6 Ah E mmHg 1 Y Ey mmHg iS ida Ia e iD oO O IG 0 x If during deflation the blood pressure monitor senses that higher pressure is required to measure the user s blood pressure the device will stop deflation and pump again to 15 reach the workable pressure up to the max 280 mmHg If the inflation continues and doesn t stop please untie the cuff immediately or turn off the unit by pressing the POWER The monitor exhausts the residual air when the measurement is completed The Heart Symbol O stops flashing and your blood pressure and pulse will appear on the display In the mean time the unit announces the measured value of Systolic Diastolic and Pulse After taking the measurement the latest measured readings will always be displayed before the power is turned off Note Wait for at least 3 minutes if you want to take another measurement Waiting allows your blood vessels to bounce back to normal status More rest time may be required between measurements depending on individual physiological conditions How to SEND MEASUREMENTS TO PC Please read SOFTWARE INSTALL AND USER S GUIDE section in this manual to install and run Medron HealthPlus 16 Software on PC What is Irregular Heartbeat An irregular heartbeat is defined as a heartbeat that Normal Heartbeat o Pulse varies by
32. ncia Siempre consulte a su m dico si aparece anormal alguno de los resultados medidos Siempre siga los procedimientos de operaci n descritos en el manual cuando se espera medir la presi n arterial correcta Aseg rese de guardar este manual y para referencia futura Enfermedades como la diabetes y l pidos hiperactivos 43 aceleran el endurecimiento de las arterias Si estas condiciones contin an existe un riesgo mayor de apoplej a e infarto coronario estenosis arterial y el desorden en la circulaci n sangu nea perif rica En estos casos habr una gran diferencia entre los valores de presi n arterial tomadas en la mu eca y el brazo Personas saludables pueden mostrar una diferencia de 20 mmHg si las condiciones del estado de la medici n no son adecuadas No conf e en la auto diagn stico o simplemente en una medida y siempre siga el consejo de un m dico Condiciones fisiol gicas pueden tener diferentes grados de efecto pero en general valores de presi n arterial en la mu eca y el brazo debe mostrar el mismo patr n de cambio En consecuencia es posible observar las tendencias en el cambio mediante la medici n de la presi n arterial en el brazo Contraindicaciones e No utilice el dispositivo en ni os y personas que no pueden expresar su propia voluntad esto puede conducir a accidentes graves e No utilice el aparato para fines distintos de medici n de la presi n arterial No utilice este dispositiv
33. nflar y medir la presi n arterial Activar o desactivar la voz en el modo de apagado e TIME Para ajustar la fecha hora e MEMO A Para revisar el registro de medici n obtenida Para seleccionar numero para fecha hora e SCAN V Revisar autom ticamente todos los registros previamente memorizado s Para seleccionar numero para de la fecha hora Para borrar el registro de mediciones memorizada s Descripci n de los S mbolos en la pantalla LCD Date Time Mon Date Hour Min Blood IM 1 10M a 10 06 1 12 08 pressure Systolic Unit A ra le yy mmHg Pressure 2 j kPa Unit B Diastolic nk an ave Average Pressure ii EE L 18 A Person 1 2 Pulse T8 Y an Low Battery Memory Pulse Symbol 47 Adaptador o Instalando Remplazando Baterias La unidad se puede utilizar con el adaptador o con baterias Asegurese de que la unidad se haya apagado antes de instalar de nuevo las bater as o las memorias y Fecha Hora se borrar n Si se retiran las bater as o desconecta el adaptador por m s de 40 segundos registros en memoria y la Fecha Hora se borrar n Entonces se debe restablecer la fecha hora Instalando Remplazando Bater as 1 Deslice tapa de compartimiento de bater as para quitarlas 2 Coloque las bater as 4 bater as AA alcalinas en el compartimiento como se indica por los s mbolos de polaridad y marcados en el interior Todos los s mbolos de la pantalla aparecer dur
34. o cerca de tel fono m vil o un horno microondas en uso error en la lectura puede ocurrir o trate de desarmar o modificar la unidad o banda del brazo esto puede da ar la unidad o causar error de lectura permanente e No empiece la inflaci n cuando la banda no se ha envuelto alrededor del brazo O No deje caer la unidad y evite golpes fuertes al dispositivo Oo Zz 44 Advertencia e Sila inflaci n contin a y no se detiene por favor desatar la banda inmediatamente o apagar la unidad presionando el bot n POWER No mida varias veces durante un periodo largo de tiempo e Este dispositivo no debe usarse si su brazo tiene alguna herida o lesi n e Retire las bater as si no se utiliza el dispositivo por mucho tiempo O No utilice bater as de diferente tipo o marca esto puede dar lugar a una medici n err nea y posiblemente causar la explosi n de la bater a con mezcla bater as alcalinas y bater as regulares e Dejando las bater as en el monitor de presi n arterial por m s de 3 meses sin usar el dispositivo puede da ar el aparato por fugas en las bater as Por favor lea la secci n de Instalaci n Sustituci n de bater as en este manual e El dispositivo podr a fallar en su funcionamiento normal si se almacena o se utiliza fuera de los rangos de temperatura y humedad se especifican a continuaci n E Ambiente para operaci n 10 C 40 C 40 85 R H Ambiente para almacenar 20 C 50 C 15
35. obre la garantia Su producto MEDRON BPC 81U monitor de presi n arterial est garantizado para estar libre de defectos de fabricaci n y materiales durante el uso normal durante un per odo de un a o a partir de la fecha de compra Para las reparaciones en garant a de un a o nuestro Agente de Servicio Autorizado deben ser informado acerca de los defectos del dispositivo Esta garant a cubre partes y mano de obra bajo un uso normal los gastos de env o y transporte de mercanc as ser n gastos del propietario Cualquier defecto que por causas naturales por ejemplo inundaciones huracanes etc no est n dentro de esta garant a Esta garant a no cubre los da os ocasionados por el uso de no seguir las instrucciones da o accidental o de ser manipulado o reparado por agentes de servicio no autorizado Para monitores sujetos a mal uso abuso negligencia del manual de instrucciones reparaciones no autorizadas o modificaciones esta garant a cesara La garant a excluye bater as Todas las reclamaciones de garant a deben dirigirse al distribuidor para la venta del dispositivo El contenido de esta garant a est sujeta a cambios sin previo aviso 63 PERSONAL BLOOD PRESSURE S RECORD Name Age Weight Date Time SYS DIA PULSE Remark 64
36. pressure mmHg Moderate hypertension Mild hypertension Optimal blood pressure Diastolic blood pressure mmHg 80 85 90 100 110 According to the blood pressure classification by the WHO ISH revised in 1999 42 Informacion importante Valores de presi n arterial medida en la casa tienden a ser menores que las habituales en el hospital Esto es causado por sentirse nervioso cuando se le mide la presi n arterial en el hospital pero se siente relajado en casa Es importante conocer su presi n arterial normal estable medida en la casa Se recomienda que las personas que tiene una de las enfermedades como problemas card acos problemas renales hipertensi n diabetes arteriosclerosis o problemas de obst culo en los vasos sangu neos por favor consulte a su m dico antes y durante el uso del monitor de presi n arterial para determinar si su presi n arterial del brazo refleja con precisi n su presi n arterial La presi n arterial fluct a sin ser notada de 30 a 50 mmHg dependiendo de si est nervioso o relajado el ejercicio o el medio ambiente temperatura o el estado mental El dispositivo puede mostrar un error de lectura en la presencia de arritmia com n tales como latidos ventriculares prematuros o arteriales o fibrilaci n arterial Precauciones Esta unidad no va a servir como cura de cualquier s ntoma de enfermedades cardiovasculares u otras enfermedades Los datos medidos son s lo para refere
37. ricity Remove the old LCD The wrong indication when power is turned on batteries and wait for one minute then install the new batteries The inflation cannot be done or the air pressure cannot rise Cuff is not wrapped properly Check the arm position and fasten the cuff correctly and re measure the pressure again Battery low Battery voltage is excessively low 6 n order to keep the previous measurements amp date time ensure the unit is turned off before replacing batteries Replaced with new AA Alkaline batteries 28 Condition Correction The blood pressure cannot be taken and the LCD shows error message or wrong result Re fasten the cuff Relax yourself Keep the cuff and heart at the same level during the measurement Keep silent and still in measurement elf the patient has severe heart beat problem and the blood pressure reading may not be correct Under normal operating circumstance the reading at home is different from that of the clinics Usually people feel tenser in the hospital or clinic white robe effect than in their home Record the results and consult with your physician Each measurement has various reading The variation might be due to the different environments eThe blood pressure is changing according to the physiological or psychological status of the human body 29
38. rograman el mes fecha hora y minuto Nota Despu s de cambiar las bater as antes de usar el monitor compruebe que la fecha y hora est n correctas Si se retiran las bater as durante m s de 40 segundos debe restablecer la fecha hora C mo aplicar la banda para el brazo 4 5 Inserte la entrada de aire de la banda en la toma de aire del monitor de presi n arterial La banda debe estar en su posici n correcta cuando se retira de la caja Si no es as pase el extremo del pu o m s alejado del tubo a trav s del metal anillo D para formar un lazo La tela suave debe estar en el interior de la banda Sila banda est montada correctamente el cierre tipo Velcro estar en la parte exterior de la banda y el anillo de metal D no debe de tocar su piel Pile Side Material Sewn Hook Material 50 7 Ponga su brazo izquierdo a trav s de la banda La parte inferior de la banda debe estar aproximadamente 1 2 por encima del codo La manguera que sale de la banda debe ser colocada a lo largo del centro de la parte interna del brazo como seamuestiaamladigura de abajo B A p i re 8 Tir los bor erior e inferior se aprietan de manera uniforme alrededor de tr brazo Left arm A 9 Cuando la banda este colocada correctamente presione el cierre tipo Velcro firmemente 10 La banda debe envolver el brazo adecuadamente de tal manera que se mantenga en su lugar Usted debe ser capaz de enc
39. rrect Measurement Position It is extremely important for the measure values which that the cuff is at the same level of the heart Higher or deeper position will give deviations from the true value Measurement while sitting down 1 Sit in a chair with your feet flat on the floor and rest your arm on a table so that the cuff is at the same level as your heart 2 Relax your arm and turn your palm upward Make sure there are no kinks in the air tubing After taking deep breaths for several times before measurement take a natural breath and then relax your body RO How to Take A Measurement Please read and follow directions in the section Suggestions before Measuring Blood Pressure and How to Apply the Arm Cuff before taking a measurement Selecting User 1 or 2 14 Press POWER button to turn on the unit All the symbols displayed for a couple seconds then the number 0 and person icon will flash Then you can press A or Y to choose user 1 or 2 The unit is ready to take measurements when the icon stopping flash If no specific user chosen the default user is 1 Press START button the cuff automatically inflates to approximately 170mmHg 50mmbg higher than the average systolic blood pressure reading 1 When the cuff reaches your correct inflation level it begins to deflate automatically with decreasing numbers shown on the display The Heart Symbol flashes as the onset of oscillatio
40. te polaridad de las s mbolo en la Baterias se bater as pantalla LCD La indicaci n equivocada cuando el aparato est encendido agotaron no tienen carga el ctrica Retire las bater as Usadas espere un minuto instale las bater as nuevas La inflaci n no se Banda no se ajusto Compruebe la puede hacer o la correctamente posici n del brazo presi n del aire no y sujete bien la puede elevarse banda vuelva a medir la presi n Bater a baja A fin de mantener Voltaje de bater a demasiado bajo las mediciones anteriores y fecha hora asegurarse que la unidad est apagada antes de cambiar las bater as Remplace con bater as alcalinas AA nuevas 60 Condici n Causa Correcci n La presi n arterial Reajuste banda no se pueden tomar ORel jese y la pantalla LCD OMantenga banda y muestra un mensaje el coraz n al de error o un mismo nivel resultado incorrecto durante medici n No hable o mueva durante medici n Si el paciente tiene problema severo de latido card aco la lectura puede ser incorrecta Bajo circunstancias normales la lectura en casa es diferente a la de las cl nicas En general la gente se siente mas tensa en el hospital o clinica efecto de bata blanca que en su casa Anote resultados y consulte con su m dico Cada medici n tiene variaci n en la lectura 61 OVariaci n
Download Pdf Manuals
Related Search
Related Contents
Allgemeines Datenblatt Atlas Quick Start for Locomotives with QSI Quantum (Titan) Omega Engineering RS-422/485 Network Router User Manual Operating Instructions Biological Safety Cabinet MSC Training : Redemittel in einer frz 78K0 System Simulator SM78K0 - Usage Restrictions AMILO Pa Series - CONRAD Produktinfo. op manual magazine @cg58.fr Copyright © All rights reserved.