Home

PRO 5.2, PRO 5.2 E, PRO 7.5, PRO 7.5 E Generator Owner`s Manual

image

Contents

1. H e well ventilated unoccupied buildings away l Do not fill fuel tank while engine is from sparks or flames Spilled fuel could hot or running ignite if it comes in contact with hot parts or sparks from ignition Never use gasoline as a Gasoline is extremely flammable and its cleaning agent vapors can explode if ignited Never refuel while smoking or in vicinity of an open flame Visually check level of fuel If necessary fill up Store gasoline only in approved containers in well ventilated unoccupied buildings away 1 Unscrew fuel tank cap K from sparks or flames Spilled fuel could 2 Fill tank until fuel gauge shows F using ignite if it comes in contact with hot parts or funnel and taking care not to spill any fuel sparks from ignition Never use gasoline as a cleaning agent 3 Screw down fuel tank cap K tightly and should NOT be used effects of z old stale or contaminated fuel are not Low permeation fuel line must be installed on warrantable carbureted Kohler Co engines to maintain EPA i and CARB regulatory compliance Fuel must meet these requirements e Clean fresh unleaded gasoline Fuel Filter e Octane rating of 86 R M 2 or higher 1 Open fuel tank cap K e Research Octane Number RON 91 octane 2 Remove fuel filter AD from tank neck minimum 3 Clean fuel filter AD with a non flammable e Gasoline up to 10 ethyl alcohol 90 solvent or solvent w
2. te Antes de llevar a cabo trabajos de Desconecte el cable del polo negativo mantenimiento o reparaci n desco de la bater a necte y a sle el cable de la buj a La seguridad es una obligaci n del propietario La inspecci n el ajuste y la lubricaci n de forma peri dica mantendr n su generador en el estado m s seguro y eficiente posible Los puntos m s importantes de inspecci n ajuste y lubricaci n del generador se explican en las siguientes p ginas Programa de mantenimiento Despu s de las 5 primeras horas e Cambie el aceite Una vez al a o o cada 25 horas e Verifique la bateria del arranque O Una vez al a o o cada 100 horas e Limpie el elemento del filtro de aire de perfil bajo V e Cambie el aceite e Limpie las zonas de refrigeraci n e Cambie la buj a Q y ajuste la separaci n Cada 200 horas e Compruebe y ajuste el juego de las v lvulas con el motor fr o Cada 300 horas e Reemplace el elemento del filtro de aire de perfil bajo V e Verifique el filtro de combustible AD y limpielo y reempl celo si es necesario 1 Estas operaciones de mantenimiento deber n ejecutarse con mayor frecuencia en ambientes muy polvorientos o sucios Pida a un distribuidor m vil de Kohler que realice esta operaci n Aseg rese de que el motor est fr o Limpie los residuos de las reas de la varilla de nivel Recomendamos el uso de un aceite de Kohler llenado N de aceite
3. 1 Desenrosque el tap n del tanque de combustible K Llene el tanque hasta que el medidor de combustible muestre la F use un embudo y tenga cuidado de no derramar nada de combustible Enrosque el tap n del tanque de combustible K con firmeza Tuber a de combustible Debe instalar una tuber a de combustible de baja permeabilidad de motores carburados de Kohler Co para respetar las normas EPA y CARB N w Filtro de combustible 1 Abra el tap n del tanque de combustible K 2 Quite el filtro de combustible AD del cuello del tanque 3 Limpie el filtro de combustible AD con un solvente incombustible o que tenga un alto punto de inflamabilidad S quelo totalmente Cambie en caso necesario 4 Vuelva a instalar el filtro de combustible AD 5 Vuelva a instalar el tap n del tanque de combustible K Cuba de sedimentos Cierre la valvula del combustible X y quite los tornillos y las tuercas de la tapa Retire la tapa w N Quite la cuba de sedimentos Limpie la cuba de sedimentos con un solvente incombustible o que tenga un alto punto de inflamabilidad S quelo totalmente Verifique la tapa y el empaque de la cuba de sedimentos Reempl celos si est n da ados A al 37 590 01 Rev B 6 Vuelva a instalar la cuba de sedimentos 7 Abra la v lvula del tanque de combustible X 8 Limpie cualquier rastro de combustible con un trapo limpio y revise q
4. Almacene el generador en un lugar seco y bien ventilado con la tapa puesta Aseg rese de no tapar el generador hasta que el motor y el silenciador protector se hayan enfriado del todo El generador debe permanecer en la misma posici n que para el funcionamiento normal N al Almacene el conjunto del generador en un lugar limpio y seco 37 590 01 Rev B Localizaci n de aver as No intente reparar o cambiar componentes principales del motor o cualquier elemento que ESS requiera unos procedimientos de ajuste o sincronizaci n especiales Este trabajo debe ser realizado por un distribuidor m vil de Kohler Problema El motor z No hay Desconexi n Causa posible no arranca 7 ea ee corriente del interruptor anormalmente el ctrica de carga Carga conectada al conjunto del generador durante el arranque Control de arranque y paro en ON 7 u OFF Nivel de aceite muy bajo Combustible inadecuado Nivel de combustible muy bajo V lvula de combustible cerrada Filtro de combustible obstruido Depurador de combustible obstruido Filtro de aire obstruido Buj a defectuosa Suministro de combustible bloqueado o con fuga Bater a del motor de arranque defectuosa Entradas de ventilaci n bloqueadas Protectores de circuitos no activados Cable de suministro de dispositivo defectuoso Tomacorrientes el ctricos defectuosos Alternador def
5. Change Oil A When change oil light Y goes on press reset SAE 30 AC and follow maintenance instructions me Change oil while engine is warm lt wao 4 Clean area around oil fill cap dipstick N and 20 32 40 50 60 80 100 oil drain plug M E 20 0 ss O SAM A e T 2 Remove oil drain plug M and oil fill cap dipstick N Drain oil completely Check Oil Level 3 Reinstall oil drain plug M Torque to NOTE To prevent extensive engine wear or 13 ft Ib 17 6 N m damage never run engine with oil level 4 Fill crankcase with new oil up to point of below or above operating range overflowing filler neck indicator on dipstick N A each Ensure engine is cool Clean oil fill dipstick N aci IP An areas of any debris 1 Remove oil fill dipstick N wipe oil off 6 Dispose of used oil in accordance with local ordinances 37 590 01 Rev B KohlerPower com N Oil Sentry if equipped Fuel Level This switch is designed to prevent engine from starting in a low oil or no oil condition Oil A Sentry may not shut down a running engine WARNING before damage occurs Explosive Fuel can cause fires and severe burns Fuel Recommendations 4 Y l Do not fill fuel tank while generator is hot or running A WARNING Gasoline is extremely flammable and E its vapors can explode if ignited Store ee cause fires gasoline only in approved containers in
6. a 1 m 3 3 ft del edificio o de cualquier otro equipo y no est tapado con ning n material 2 Consulte todas las etiquetas de advertencia antes de poner en marcha 3 Compruebe el nivel de aceite por medio del tap n de llenado de aceite N A ada aceite si est bajo No rellene por encima del l mite 4 Verifique el indicador de nivel de combustible L A ada combustible si est bajo Deje de rellenar cuando el indicador haya alcanzado el nivel F lleno Compruebe si los compo nentes y las tuber as del sistema de combus tible presentan alguna fuga No reposte nunca con la unidad en funcionamiento 5 Pruebe el recept culo GFCI G 6 Verifique que los componentes del filtro de aire y todas las entradas de aire est n libres de obstrucciones y que las cubiertas y proteccio nes del equipo est n en su sitio y bien sujetas 7 Aseg rese de que no haya dispositivos el ctricos carga conectados al generador Arranque amp PELIGRO El uso de un generador en interiores PUEDE MATAR A UNA PERSONA EN CUESTION DE MINUTOS Los gases de escape del generador pueden contener mon xido de carbono Este es un gas t xico que no se ve ni se huele E w No utilice NUNCA el generador en el Utilice s lo AL AIRE LIBRE interior de su hogar ni en un garaje y lejos de ventanas puertas NI SIQUIERA con las puertas y y orificios de ventilaci n ventanas abiertas A ADVERTENCIA ko Las piezas rotatorias p
7. est en la posici n de 120V 240V 120V se suministra a todos los tomacorrientes el ctricos C D y G y 240V a los tomacorrientes el ctricos de 240 120V 30A C Cuando el interruptor de este selector AE est en la posici n de 120V solo se suministran 120V a los tomacorrientes el ctricos D y G Aseg rese de colocar el interruptor de carga principal A en la posici n de OFF antes de usar el interruptor del selector de voltaje AE para evitar el da o accidental al generador debido a cualquier carga conectada que pueda extraer energ a de la unidad 37 590 01 Rev B Potencia del recept culo del selector de voltaje Potencia Disponible Posici n del Tomacorriente PRO 5 2 Interruptor el ctrico PRO 5 2 E 240V 120V 30A 30A 120V S lo 120V 120V 30A 30A 120V GFCI 20A 120V 240V 120V 30A 18 5A 240V 120V 240V 120V 30A 18 5A 120V GFCI 18 5A 120V recept culo de CC si lo tiene Y A Precauci n Las descargas el ctricas pueden provocar lesiones No utilice nunca el generador bajo la lluvia o la nieve No toque los cables con el generador en funcionamiento No toque nunca el generador con las manos mojadas ya que podr a producirse una descarga el ctrica NOTA Esta secci n se refiere a la carga de bater as de 12 V en otros equipos como veh culos de motor o veh culos todoterreno No es posible el arranque con pinzas Siga los pr
8. n de en la varilla N llenado con varilla N Drene el aceite por completo 37 590 01 Rev B KohlerPower com 23 w A al o Vuelva a instalar el tap n de drenaje del aceite M Apri telo a 17 6 N m 13 ft Ib Llene de aceite nuevo el c rter hasta el punto de desbordamiento del cuello de llenado Vuelva a colocar el tap n varilla de nivel llenado N y apriete firmemente Deseche el aceite usado en conformidad con las normativas locales Oil Sentry si est incluido Este interruptor est dise ado para evitar que e motor arranque con poco aceite o ninguno El Oil Sentry no puede apagar un motor en marcha antes de que se produzca un da o Recomendaciones de combustible A ADVERTENCIA La explosi n del carburante puede provocar incendios y e de quemaduras graves A l No llene el tanque de combustible con el motor en funcionamiento o caliente La gasolina es muy inflamable y sus vapores pueden hacer explosi n si se inflaman No reposte nunca mientras fuma ni cerca de una llama al descubierto Almacene la gasolina siempre en contenedores homologados en locales desocupados bien ventilados y lejos de chispas o llamas El combustible derramado podr a inflamarse si entra en contacto con las piezas calientes del motor O las chispas de encendido No utilice nunca gasolina como agente de limpieza NOTA E15 E20 y E85 are NO est n autorizados y
9. All rights reserved KohlerPower com Kit de manivelas manuales para cami n amp NOTA Un dispositivo o asistente de sujeci n para sostener el ensamblaje mientras que el kit de instalaci n facilita el proceso El kit de manivelas manuales para cami n incluye la manivela y herramienta de montaje 1 Coloque la manivela manual del cami n en la unidad alineando los orificios del bastidor y de la manivela 2 Coloque la arandela entre la manivela y el bastidor 3 Mientras lo mantiene en esa posici n instale los tornillos 4 Enrosque las tuercas en los tornillos Apri telo a 0 5 N m 4 in Ib 5 Instale la rueda de liberaci n a trav s del bastidor Coloque la arandela y el pasador de sujeci n dentro del ensamblaje Instalaci n del kit del aislador Kit de aislador TT a U ge AR gt ee El kit del aislador incluye 4 aisladores y herramienta de montaje 1 Alinee los orificios del aislador con los orificios del bastidor 2 Mientras lo mantiene en esa posici n instale los tornillos 3 Enrosque las tuercas en los tornillos Aplique un par de apriete de 25 Nm 221 in lb 37 590 01 Rev B
10. Fuel Valve re Replace Spark Replace Air Low Oil Change Oil Light E Plug Light aa Cleaner Light agai indicator Light Reset Fuel Filter ES Voltage Selector PRO 5 2 and PRO 5 2 E only California only Electric start models only 4 KohlerPower com 37 590 01 Rev B Pre Start Checklist 1 Ensure generator is at least 3 3 ft 1 m from building or other equipment and not covered with any material 2 Refer to all warning labels prior to starting 3 Check oil level using oil fill cap N Add oil if low Do not overfill 4 Check fuel level indicator L Add fuel if low Stop refueling when indicator reaches F full level Check fuel system components and lines for leaks Never refuel while unit is running 5 Test GFCI receptacle G 6 Check that air cleaner components and all air inlets are unobstructed equipment covers and guards are in place and securely fastened 7 Ensure electrical devices load are not connected to generator Starting 4 amp DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell 5 EF m NEVER use inside a home Only use OUTSIDE and far or garage EVEN IF doors away from windows door and windows are open and vents A WARNING ko Rotating Parts can cause severe T injury 0 Stay away while engine is in operation Keep hands feet hair
11. KohlerPower com 19 ESS KOLER ES A 4 Tapa del filtro de aire Tornillo de arranque diia fino de ES de combustible Reemplazar la A l mpara del filtro de WANs dicador luminoso de aceite bajo aire Selector de voltaje Elemento de espuma Cambiar la l mpara del aceite Cambiar la l mpara de la buj a AA L A Interruptor de Mantenimiento del Tomacorriente Tomacorriente tect Cc el ctrico de l ctrico de 120V 30A carga protector 240 120V 30A el ctrico de Protector de Receptaculo de CC A circuitos de 12V3 Receptaculo GFCI EN Terminal de masa P fe Interruptor de encendi Tap n del tanque de Indicador del nivel de 3 Ralentautomatico do apagado arranque combustible E combustible Tap n de drenaje Tap n de llenado de Bater a del motor de Palanca del del aceite aceite varilla de nivel arranque estrangulador Restablecer Cartucho de carb n E Manivela del motor Filtro de combustible Solo PRO 5 2 y PRO 5 2 E Solo California Solo modelos de arranque el ctrico 20 KohlerPower com 37 590 01 Rev B Lista de control previa al arranque 1 Aseg rese de que el generador est al menos
12. and clothing away from all moving parts to prevent injury Never operate engine with covers shrouds or guards removed NOTE Auto Idle I switch must be in OFF position when using electric devices that require a large starting current such as a compressor or a submersible pump Auto Idle 1 controls engine speed according to connected load Results are better fuel consumption and less noise NOTE Choke is not required to start a warm engine Push choke lever P in to original position Turn main AC circuit breaker A OFF EN Turn Auto Idle 1 OFF if equipped Turn Fuel X ON Turn engine to ON J and pull rope or push start button J for electric start Turn choke lever P OFF after engine is warm Bon al If engine does not start repeat operation until engine starts by gradually opening choke Cold Weather Starting 1 Use proper oil for temperature expected 2 Disengage all possible external loads 3 Use fresh winter grade fuel Winter grade fuel has higher volatility to improve starting Operation A caurion W Hazardous Voltage Backfeed to utility system can E cause property damage severe injury or death Never plug a portable generator directly into a building outlet If generator is used for standby power have a certified licensed electrician install an automatic transfer switch to prevent inadvertent interconnection of standby and normal
13. carretillas incluye dos manivelas y herramienta de montaje 1 Alinee la manivela con los orificios del bastidor 2 Coloque las arandelas entre la manivela y el bastidor mientras coloca el tornillo 3 Enrosque la tuerca al tornillo Apri telo a 0 5 N m 4 in Ib KohlerPower com 31 Instalaci n del kit para manejo de cables Instalaci n de kit de manivelas manuales para camion lt Kit de cables El kit de manejo de cables incluye 2 montantes y herramienta de montaje El kit de manejo de cables se puede instalar en cualquier lugar de la unidad del mismo lado no por toda la unidad 1 Coloque los lados del montante juntos en el bastidor 2 Coloque 3 tuercas en los orificios de 1 lado 3 Mientras los sostiene juntos inserte los tornillos del otro lado y enr squelos en las tuercas Apri telo a 25 Nm 221 in Ib Instalaci n del kit de elevaci n Kit de accesorios de elevaci n a a ed De NOTA Un dispositivo o asistente de sujeci n para sostener el ensamblaje mientras que el kit de instalaci n facilita el proceso El kit de elevaci n incluye una barra de elevaci n y herramienta de montaje 1 Alinee los orificios de la barra de elevaci n con los orificios del bastidor 2 Mientras lo mantiene en esa posici n instale los tornillos 3 Enrosque las tuercas en los tornillos Aplique un par de apriete de 25 Nm 221 in Ib O 2013 by Kohler Co
14. de carga V ase la secci n de combustible 30 2 L 8 gal 0 76 mm 0 03 in Si se excede el ngulo m ximo de funcionamiento puede da arse el motor debido a lubricaci n insuficiente Puede encontrar informaci n adicional sobre las especificaciones en KohlerPower com El sistema de control de emisiones de escape para modelos PRO 5 2 PRO 5 2 E PRO 7 5 y PRO 7 5 E es EM para la EPA estadounidense California y Europa Sistema de accesorios Kits de accesorios disponibles para los modelos de la siguiente tabla que incluyen kits personalizados formados por kits de patas manivelas ruedas y aditamentos de elevaci n lo que desee y c mo desee Sistema de accesorios PRO 5 2 PRO 7 5 5 2E 7 5E TP 3 0 Kit de ruedas e e e Kit de patas e e e Kit de accesorios de elevaci n e e Kit de manivelas para carretillas e e Kit para manejo de cables e o o Kit de manivelas manuales para cami n e Kit de aislador e e e 30 KohlerPower com 37 590 01 Rev B Instalacion de kit de ruedas Instalacion del kit de patas Kit de ruedas Kit de patas ESS Kit de ruedas 4 ruedas NOTA Incline la unidad de manera que el tap n del tanque de combustible quede hacia arriba para asegurar que no haya fuga de combustible Un dispositivo o asistente de sujeci n para
15. ft Ib 27 N m Air Cleaner NOTE Operating engine with loose or damaged air cleaner components could cause premature wear and failure Replace all bent or damaged components When replace air cleaner light AA goes on press reset AC and follow maintenance instructions 1 Remove screw T and air cleaner cover U 2 Remove foam element V from air cleaner base W 3 Wash foam element V in warm water with detergent Rinse and allow to air dry 4 Lightly oil foam element V with new engine oil squeeze out excess oil 5 Reinstall foam element V into air cleaner base W 6 Reinstall cover and secure with screw T Breather Tube Ensure both ends of breather tube are properly connected 37 590 01 Rev B KohlerPower com A WARNING Hot Parts can cause severe burns Do not touch generator while operating or just after stopping A pi Never operate generator with heat shields or guards removed Do not modify generator Place generator in a place where pedestrians or children are not likely to touch generator Be sure to carry generator only by its carrying handles Proper cooling is essential To prevent over heating ensure air cooling inlet and outlet areas are clean and unobstructed Avoid spraying water at wiring harness or any electrical components Refer to Maintenance Schedule Ground Terminal Ground terminal H connects earth line for prevention o
16. generator EN 2 Press DC circuit protector E in 3 Connect red battery charger lead to positive battery terminal Connect black battery charger lead to negative battery terminal Do not reverse these positions Connect cord to DC receptacle F Operating Range of DC Power Supply Charging 12V battery only This power source is designed to charge batteries up to 40Ah that are half discharged Do not charge batteries of a higher capacity than 40Ah 12V Battery Time required for recharging a battery varies depending on discharge level of battery When specific gravity of battery reaches 1 26 to 1 28 charging is complete When charging check battery s specific gravity once an hour Average time for charging a half discharged 40Ah battery is approximately 5 hours Be sure to check battery fluid level before charging DC Circuit Protector NOTE Reduce load of connected electric device below specified rated output of generator if DC circuit protector E turns off If DC circuit protector E turns off again stop using device immediately and contact a Kohler portable dealer DC circuit protector E button will pop out stopping power to DC receptacle F when electric device being connected to generator is operating at current above rated flows To use this equipment again press DC circuit protector E button Starter Battery if equipped As starter battery O is maintenance free just check condition and tigh
17. plug a portable generator directly into a building outlet If generator is used for standby power have a certified licensed electrician install an automatic transfer switch to prevent inadvertent interconnection of standby and normal sources of supply California Proposition 65 Warning Engine exhaust from this product contains chemicals known to State of California to cause cancer birth defects or other reproductive harm KohlerPower com 37 590 01 Rev B Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell as NEVER use inside a home Only use OUTSIDE and far or garage EVEN IF doors away from windows door and windows are open and vents Avoid other generator hazards READ MANUAL BEFORE USE 4 WARNING e Hot parts can cause severe burns e Do not touch generator while operating or just after stopping HOT EXHAUST amp ADVERTENCIA Las piezas calientes pueden causar quemaduras graves No toque el generador durante el funcionamiento o inmediatamente despu s de pararse e Explosive Fuel can cause fires and severe burns e Do not fill fuel tank while generator is hot or running e Carbon monoxide can cause severe nausea fainting or death e Avoid inhaling exhaust fumes La explosi n del carburante puede provocar incendios y quemaduras graves No llene el tanque de com
18. sostener el ensamblaje mientras que el kit de instalaci n facilita el proceso El kit de ruedas incluye 2 ruedas y herramienta de montaje para instalarse del lado opuesto al motor Los kits de ruedas y de patas est n dise ados para instalarse juntos Se pueden combinar 2 kits de ruedas para una configuraci n de 4 ruedas NOTA 1 Coloque 4 tornillos en los orificios del bastidor 2 Lleve el soporte de la rueda bajo el bastidor y alinee los tornillos con los orificios del soporte 3 Enrosque las tuercas en los tornillos Aplique un par de apriete de 221 in Ib 25 Nm 37 590 01 Rev B NOTA Incline la unidad de manera que el tap n del tanque de combustible quede hacia arriba para asegurar que no haya fuga de combustible Un dispositivo o asistente de sujeci n para sostener el ensamblaje mientras que el kit de instalaci n facilita el proceso El kit de patas incluye 2 patas y herramienta de montaje Los kits de patas y ruedas est n dise ados para instalarse juntos Se pueden combinar 2 kits de patas para una configuraci n de 4 patas 1 Coloque 4 tornillos en los orificios del bastidor 2 Lleve la pata bajo el bastidor y alinee los tornillos con los orificios de las patas 3 Enrosque las tuercas en los tornillos Aplique un par de apriete de 221 in Ib 25 Nm Instalacion de kit de manivelas para carretillas Kit de manivelas para carretillas NOTA EI kit de manivelas para
19. ESET del interruptor del circuito de fallos de conexi n a tierra GFCI salta repentinamente de forma repetida durante el uso Recuerde que s lo los receptaculos con la etiqueta GFCI est n protegidos por un interruptor del circuito de fallos de conexi n a tierra El interruptor del circuito de fallos de conexi n a tierra GFCI interrumpe el paso de corriente a los recept culos protegidos G si se detecta un fallo de conexi n a tierra escape el ctrico Si el bot n RESET salta hacia fuera es posible que el equipo enchufado al recept culo G est defectuoso Si esto ocurre examine con atenci n el equipo Si el equipo parece estar en buenas condiciones pulse firmemente el bot n RESET hasta o r un chasquido De esta forma se restablecer la corriente Si el bot n RESET vuelve a saltar desenchufe el equipo inmediatamente P ngase en contacto con un distribuidor m vil de Kohler antes de volver a utilizarlo Prueba del recept culo GFCI 1 Arranque el motor 2 Pulse el bot n TEST si funciona correctamente el bot n RESET deber saltar hacia fuera interrumpiendo la corriente enviada a la salida N 3 Si el funcionamiento del GFCI es correcto presione el bot n RESET hacia adentro Si el GFCI no funciona correctamente p ngase en contacto con un distribuidor m vil de Kohler 26 KohlerPower com Sobrecarga capacidad del generador No supere nunca la carga nominal del generador en amperios y
20. KOHLER p PRO 5 2 PRO 5 2 E PRO 7 5 PRO 7 5 E Generator Owner s Manual IMPORTANT Read all safety precautions and instructions carefully before operating equipment Ensure engine is stopped and level before performing any maintenance or service Record product information to reference when ordering parts or obtaining warranty coverage Specification Serial Number Purchase Date 37 590 01 Rev B KohlerPower com Safety Precautions A DANGER Ahazard that will result in death serious injury or substantial property damage 4 amp WARNING Ahazard that could result in death serious injury or substantial property damage A CAUTION Ahazard that could result in minor personal injury or property damage NOTE is used to notify people of important installation operation or maintenance information Read this manual carefully before operating this machine This manual should stay with this machine if it is sold A WARNING Explosive Fuel can cause fires and severe gt burns e A Do not fill fuel tank while engine is hot or running A CAUTION Electrical Shock can cause injury Do not touch oe wires while generator is running Gasoline is extremely flammable and its vapors can explode if ignited Never refuel while smoking or in vicinity of an open flame Store gasoline only in approved containers in well ventilated unoccupied buildings away from s
21. NO deben utilizarse la garant a no cubre los efectos producidos por el uso de combustible antiguo pasado o contaminado El combustible debe cumplir con los siguientes requisitos 24 Gasolina limpia fresca y sin plomo Octanaje de 86 R M 2 o superior El Research Octane Number RON deber ser de 91 octanos como m nimo Se autoriza el empleo de gasolina de hasta un volumen m ximo del 10 de alcohol et lico y el 90 sin plomo Se autorizan las mezclas de metil ter butil ter MTBE y gasolina sin plomo hasta un m ximo del 15 de MTBE en volumen No a ada aceite a la gasolina No llene el tanque de combustible por encima del l mite No utilice gasolina con m s de 30 d as de antig edad KohlerPower com Nivel de combustible A ADVERTENCIA La explosi n del carburante puede provocar incendios y s de quemaduras graves A l No llene el tanque de combustible con el generador en funcionamiento o caliente La gasolina es muy inflamable y sus vapores pueden hacer explosi n si se inflaman Almacene la gasolina siempre en contenedo res homologados en locales desocupados bien ventilados y lejos de chispas o llamas El combustible derramado podr a inflamarse si entra en contacto con las piezas calientes del motor o las chispas de encendido No utilice nunca gasolina como agente de limpieza Verifique el nivel de combustible visualmente Si es necesario rellene
22. away from windows door and windows are open and vents Avoid other generator hazards READ MANUAL BEFORE USE 4 WARNING e Hot parts can cause severe burns e Do not touch generator while operating or just after stopping HOT EXHAUST amp ADVERTENCIA Las piezas calientes pueden causar quemaduras graves No toque el generador durante el funcionamiento o inmediatamente despu s de pararse e Explosive Fuel can cause fires and severe burns e Do not fill fuel tank while generator is hot or running e Carbon monoxide can cause severe nausea fainting or death e Avoid inhaling exhaust fumes La explosi n del carburante puede provocar incendios y quemaduras graves No llene el tanque de combustible mientras el generador est caliente o funcionando El mon xido de carbono puede provocar n useas mareos o la muerte e Evite inhalar los humos del escape e Electrical shock can cause injury e Do not touch wires while generator is running e Do not connect generator to a building s electrical system unless using an isolation transfer switch installed by a certified licensed electrician Las descargas el ctricas pueden provocar lesiones No toque los cables con el generador en funcionament No conecte el generador al sistema el ctrico de un edificio a menos que use un aislamiento transferencia interruptor instalado por un electricista certificado y certificado 37 590 01 Rev B
23. bustible mientras el generador est caliente o funcionando El mon xido de carbono puede provocar n useas mareos o la muerte e Evite inhalar los humos del escape e Electrical shock can cause injury e Do not touch wires while generator is running e Do not connect generator to a building s electrical system unless using an isolation transfer switch installed by a certified licensed electrician Las descargas el ctricas pueden provocar lesiones No toque los cables con el generador en funcionament No conecte el generador al sistema el ctrico de un edificio a menos que use un aislamiento transferencia interruptor instalado por un electricista certificado y certificado 37 590 01 Rev B KohlerPower com ay s YS El A y S Oy M A eae Maintenance 240 120V 30A 120V 30A Circuit Breaker e Minder Electrical Socket m Electrical Socket Circuit Protector M3 12V DC GFCI Receptacle Ground Terminal Receptacle P Auto Idle Onon Start Ea Fuel Tank Cap Fuel Level Oil Drain Plug ES dd ES Starter Battery E Choke Lever Spark Plug ia Carbon Canister s Starter Handle Screw Air Cleaner Cover AM Foam Element w Base
24. del generador Secci n transversal E g E g E g del cable EJZ EJZ E recomendada 0a 4 101 6 9 10 7 Longi 50m tud del cable 942 10 7 10 7 25 3 que se utiliz 101 a 150 m 10 7 16 5 35 2 1 La longitud de este cable es la m xima permitida y no se debe exceder M todo de instalaci n cables en el canal o en la tablilla sin perforaciones Ca da permiti da en voltaje 5 Conductores multin cleo Tipo de cable PVC 70 C por ejemplo HO7R NF Temperatura ambiente 86 F 30 C Interruptor de encendido apagado arranque El interruptor de encendido apagado arranque 1 controla el sistema de encendido Posici n ON El circuito de encendido est activado El motor se puede poner en marcha Posici n OFF El circuito de encendido est desactivado El motor no arranca Posici n de arranque START Al presionar y sostener el interruptor en la posici n de arranque se encender el motor con el arranque el ctrico si lo tiene 22 KohlerPower com Ralent autom tico Cuando el interruptor de ralent autom tico I est en la posici n de ON el ralent autom tico I controla la velocidad del motor de acuerdo con la carga conectada Los resultados son un mejor consumo de combustible y menos ruido Cuando el interruptor de ralent autom tico P est en la posici n OFF el motor funciona al nivel nominal de rpm 3 600 rpm haya o
25. ecte todas las posibles cargas externas N w Use combustible de grado invierno reciente El combustible de grado invierno tiene una mayor volatilidad que mejora el arranque Funcionamiento A PRECAUCI N Tensi n peligrosa La retroalimentaci n al sistema ts de suministro el ctrico puede causar da os materiales lesiones graves o la muerte No conecte nunca un generador port til directamente a la toma de un edificio Si el generador se va a utilizar para corriente auxiliar pida a un electricista autorizado y cualificado que instale un conmutador de transferencia autom tico para evitar la interconexi n accidental de las fuentes de alimentaci n auxiliar y normal Cuando la velocidad de operaci n del conjunto de generaci n se haya estabilizado aproximadamente 3 minutos 1 Verifique que los protectores de los circuitos E est n oprimidos Presione si es necesario 2 Conecte los aparatos a los tomacorrientes el ctricos C D amp G del generador 3 El mantenimiento del protector B muestra la cantidad de horas que ha funcionado el generador 37 590 01 Rev B KohlerPower com 21 ngulo de funcionamiento No haga funcionar el motor si supera el ngulo m ximo de funcionamiento consulte la tabla de especificaciones El motor puede da arse como resultado de una lubricaci n insuficiente Selecci n del cable Tipo de tomacorriente 10A 16A 32A
26. ectuoso Dispositivo conectado o cable defectuoso Sobrecarga Bater a mal conectada 37 590 01 Rev B KohlerPower com 29 Modelo Ancho x Alto Orificio Carrera Combustible combustible Especificaciones Dimensiones generales Largo x Peso en seco Potencia nominal de CA Elevaci n de potencia de CA Potencia nominal de CC Especificaciones del motor Desplazamiento Capacidad de aceite rellenado ngulo de funcionamiento m ximo con nivel m ximo de aceite Tiempo de funcionamiento Capacidad del tanque de Abertura de buj a PRO 5 2 PRO 5 2 E PRO 7 5 PRO 7 5 E 670 mm 26 4 in 545 mm 21 5 in 535 mm 21 1 in 670 mm 26 4 in 545 mm 21 5 in 535 mm 21 1 in 168 Ibs 76 kg 189 lbs 86 kg 199 Ibs 90 kg 220 Ibs 100 kg 4500 W 120 voltios x 37 5 amperios 240 voltios x 18 8 amperios 6300 W 120 voltios x 52 5 amperios 240 voltios x 26 3 amperios 5200 W 120 voltios x 43 3 amperios 240 voltios x 21 7 amperios 7500 W 120 voltios x 62 5 amperios 240 voltios x 31 3 amperios 100 W 12 voltios x 8 3 amperes 78 mm 3 1 in 89 mm 3 5 in 58 mm 2 3 in 69 mm 2 7 in 16 9 cu in 277 cc 24 7 cu in 429 cc 1 16 U S qt 1 1 L 25 7 10 5 horas carga nominal 1 2 de carga 10 15 horas carga nominal 1 2
27. f electric shock When electric device is grounded be sure to ground generator also Connect generator to ground Attach a 6 AWG 10 mm copper wire to generator s ground connection and to a galvanized steel grounding rod not provided driven 3 3 ft 1 m into ground Connecting Alternating Current AC NOTE Ensure all electric devices including lines and plug connection are in good condition before connection to generator NOTE Ensure total load is within generator rated output NOTE Ensure receptacle load current is within receptacle rated current 1 Start engine 2 Plug into AC receptacle C D or G 3 Turn on any electric devices AC Rated Power AC rated power is maximum amount of power generator can support AC Surge Power AC surge power is additional power generator momentarily produces to aid in starting of electrical devices requiring power above generator s rated power requirements o EN GFCI Receptacle X ly A caution Electrical Shock can cause injury Never operate generator in rain or snow Never touch generator with wet hands or electrical shock may occur Do not touch wires while generator is running To reduce chance of electrical shock 1 Do not attempt to operate equipment if ground fault circuit interrupter GFCI RESET button M pops out repeatedly during use Remember that only receptacles labeled GFCI have ground fault circuit interr
28. f engine will be out of service for 2 months or more follow procedure below 1 Add Kohler PRO Series fuel treatment or equivalent to fuel tank Run engine 2 3 minutes to get stabilized fuel into fuel system failures due to untreated fuel are not warrantable Change oil while engine is still warm from operation Remove spark plug Q and pour about 1 oz of engine oil into cylinder s Replace spark plug Q and crank engine slowly to distribute oil Clean generator Store generator in a dry well ventilated place with cover placed over it When covering generator be sure to do so only after engine and muffler shield have completely cooled down Generator must remain in same position as normal operation Store generating set in a clean and dry place w N A 0 al 12 KohlerPower com 37 590 01 Rev B Troubleshooting EN Do not attempt to service or replace major engine components or any items that require special timing or adjustment procedures This work should be performed by a Kohler portable dealer Possible Cause Load connected to generating set during start up Problem Engine Not PON Starting Engine No Electric Tripping of Running Stopped Current Breaker Abnormally Start and Stop control ON or OFF Oil level too low Unsuitable fuel Fuel level too low Fuel valve closed Clogged fuel filter Clogged fuel strainer Clogged air filter Faulty spar
29. ith a high flash point Dry unleaded is acceptable it fully Replace as necessary e Methyl Tertiary Butyl Ether MTBE and 4 Reinstall fuel filter AD unleaded gasoline blend max 15 MTBE by 5 Reinstall fuel tank cap K volume are approved i e Do not add oil to gasoline Sediment Bowl Do not overfill fuel tank Do not use gasoline older than 30 days Close fuel valve X and remove cover screws and nuts N Remove cover w Remove sediment bowl A Clean sediment bowl with a non flammable solvent or solvent with a high flash point Dry it fully Check sediment bowl cover and gasket Replace them if they are damaged Reinstall sediment bowl Open tank fuel valve X Wipe off any trace of fuel with a clean cloth and check for any leakage al o NO 8 KohlerPower com 37 590 01 Rev B Spark Plugs Air Cooling A CAUTION Electrical Shock can cause injury Do not touch wires while generator is running A Never operate generator in rain or snow Never touch generator with wet hands or electrical shock may occur When replace spark plug light Z goes on press reset AC and follow maintenance instructions Clean out spark plug recess Remove spark plug Q and replace 1 Check gap using wire feeler gauge Adjust gap see specification table for adjustment 2 Install spark plug Q into cylinder head 3 Torque spark plug Q to 20
30. k plug Fuel supply blocked or leaking Faulty starter battery Blocked ventilation inlets Circuit protectors not actuated Faulty appliance supply cord Faulty electrical sockets Faulty alternator Device connected or faulty cord Overload Battery Incorrectly Connected 37 590 01 Rev B KohlerPower com 13 Specifications CECE PRO 5 2 PRO5 2E PRO 7 5 PRO 7 5 E 26 4 in 670 mm 26 4 in 670 mm Overall Dimensions L x W x H 21 5 in 545 mm 21 5 in 545 mm 21 1 in 535 mm 21 1 in 535 mm 168 Ibs 76 kg 199 Ibs 90 kg Dry Weight 189 Ibs 86 kg 220 Ibs 100 kg 120 Volts x 120 Volts x 37 5 Amps 52 5 Amps AC Rated Power 4500 Watt 240 Volts x 6300 Watt 240 Volts x 18 8 Amps 26 3 Amps 120 Volts x 120 Volts x 43 3 Amps 62 5 Amps AC Surge Power 5200 Watt 240 Volts x 7500 Watt 240 Volts x 21 7 Amps 31 3 Amps DC Rated Power 100 Watt 12 Volts x 8 3 Amps Engine Specifications 3 1 in 78 mm 3 5 in 89 mm 2 3 in 58 mm 2 7 in 69 mm 16 9 cu in 277 cc 24 7 cu in 429 cc Oil Capacity Refill 1 16 U S qt 1 1 L Maximum Angle of Operation 25 full oil level teaa a bed NTE 2 load See fuel section Fuel Tank Capacity 8 gal 30 2 L Spark Plug Gap 0 03 in 0 76 mm Exceeding maximum angle of operation may cause engine damage from insufficie
31. le I switch is in ON position Auto Idle I controls engine speed according to connected load Results are better fuel consumption and less noise When Auto Idle I switch is in OFF position engine runs at rated rpm 3 600 rpm regardless of whether there is a load connected or not Stopping 1 Disconnect plugs from electrical sockets C D F amp G to let engine run under no load for 1 or 2 minutes 2 Set ON OFF START switch J to OFF position generator stops 3 Close fuel valve X High Altitude Operation This generator may require a high altitude carburetor kit to ensure correct engine operation at altitudes above 4000 ft 1219 meters To obtain high altitude kit information or to find a Kohler portable dealer go to KohlerPower com or call 1 800 544 2444 This generator should be operated in its original configuration below 4000 ft 1219 meters as damage may occur if high altitude carburetor kit is installed and operated below 4000 ft 1219 meters Engine Speed NOTE Do not tamper with governor setting to increase maximum engine speed Overspeed is hazardous and will void warranty 37 590 01 Rev B Maintenance Instructions W A WARNING Before working on engine or equipment disable AO Accidental Starts can cause engine as follows 1 Disconnect spark plug severe injury or death lead s 2 Disconnect negative battery cable e Disconnect and ground spark from batter
32. nizado no incluida introducida 1 m 3 3 ft en el suelo Conexi n de corriente alterna CA NOTA Aseg rese de que todos los dispositivos el ctricos incluidos los cables y enchufe de conexi n est n en buenas condiciones antes de conectarlos al generador NOTA Aseg rese de que la carga total est dentro de los l mites de salida nominal del generador NOTA Aseg rese de que la corriente de carga del recept culo est dentro de los l mites de corriente nominal del recept culo 1 Arranque el motor 2 Enchufe en el recept culo de CA C D o G 3 Encienda cualquier dispositivo el ctrico Potencia nominal de CA La potencia nominal de CA es la cantidad de potencia m xima que puede soportar el generador ESS Elevaci n de potencia de CA La elevaci n de potencia de CA es una potencia adicional producida moment neamente por el generador para ayudar a poner en marcha dispositivos el ctricos que requieren una potencia superior a la potencia nominal del generador Recept culo GFCI A PRECAUCI N Las descargas el ctricas pueden provocar lesiones UY No toque los cables con el generador en funcionamiento No utilice nunca el generador bajo la lluvia o la nieve No toque nunca el generador con las manos mojadas ya que podr a producirse una descarga el ctrica Con el fin de reducir la posibilidad de descarga el ctrica 1 No intente operar el equipo si el bot n R
33. no una carga conectada Parada Desconecte los tapones de los tomacorrientes el ctricos C D F y G para permitir que el motor funcione sin carga por 1 0 2 minutos N Fije el interruptor de encendido apagado arranque J en la posici n OFF se detiene el generador 3 Cierre de la v lvula de combustible X Funcionamiento a gran altitud Este generador puede requerir un kit de carburador de gran altitud para garantizar un funcionamiento correcto del motor a altitudes superiores a 1 219 metros 4 000 pies Para obtener informaci n del kit de gran altitud o encontrar a un distribuidor de Kohler visite KohlerPower com o llame al 1 800 544 2444 Este generador debe ponerse en funcionamiento en su configuraci n original por debajo de los 1 219 metros 4 000 pies pues pueden producirse da os si se instala y pone en funcionamiento el kit de carburador de gran altitud por debajo de los 1 219 metros 4 000 pies Velocidad del motor NOTA No altere los ajustes del regulador para aumentar la velocidad m xima del motor El exceso de velocidad es peligroso y anular la garant a 37 590 01 Rev B Instrucciones de mantenimiento Wy A ADVERTENCIA Antes de realizar cualquier trabajo en el motor o en el equipo desactive el motor como se indica a continuaci n 1 Desconecte los cables de las buj as 2 Los arranques accidentales pueden A provocar lesiones graves o la muerte
34. nstall Leg Kit Leg Kit NOTE Tilt unit so fuel tank cap is upward to ensure no fuel leakage NOTE Aclamping device or an assistant to hold assembly while installing kit will make process easier Leg kit includes 2 legs and mounting hardware Leg kit and wheel kit are designed to be installed together 2 leg kits can be combined for a 4 legged configuration 1 Place 4 screws into holes of frame 2 Bring leg under frame and align screws with leg holes 3 Thread nuts to screws Torque to 221 in Ib 25 N m KohlerPower com 15 Install Wheelbarrow Handle Kit Wheelbarrow Handle Kit NOTE Aclamping device or an assistant to hold assembly while installing kit will make process easier Lift kit includes lift bar and mounting hardware 1 Align lift bar holes under holes of frame 2 While holding in this position install screws 3 Thread nuts to screws Torque to 221 in Ib 25 N m Install Hand Truck Handle Kit Hand Truck Handle Kit Wheelbarrow handle kit includes two wheelbarrow handles and mounting hardware 1 Align handle with holes on frame 2 Place washers between handle and frame while installing screw 3 Thread nut to screw Torque to 4 in lb 0 5 N m Install Cord Management Kit Cord Kit Cord management kit includes 2 posts and mounting hardware Cord management kit can be installed anywhere on unit on same side not across
35. nt lubrication Additional specification information can be found at KohlerPower com Exhaust Emission Control System for models PRO 5 2 PRO 5 2 E PRO 7 5 and PRO 7 5 E is EM for U S EPA California and Europe 14 KohlerPower com 37 590 01 Rev B Accessory System EN Accessory kits available for models in table below which includes custom kits consisting of legs handles wheels lifting kits whatever you want any way you want it PRO 5 2 PRO 7 5 Accessory System 5 2 E pS oy CERDA lt Wheel Kit Wheels and Legs Wheel Kit 4 Wheels Tilt unit so fuel tank cap is upward to ensure no fuel leakage 37 590 01 Rev B Wheel Kit e e e e Leg Kit e o Lifting Kit Wheelbarrow Handle Kit o o e e Cord Management Kit e e Hand Truck Handle Kit e o Isolator Kit e o e e e a NOTE Aclamping device or an assistant to Install Wheel Kit hold assembly while installing kit wil make process easier Wheel Kit ion p Wheel kit includes 2 wheels and mounting hardware to be installed opposite of engine e side Wheel kit and leg kit are designed to e e be installed together 2 wheel kits can be es combined for a 4 wheel configuration 1 Place 4 screws into holes of frame 2 Bring bracket of wheel under frame and align screws with bracket holes 3 Thread nuts to screws Torque to 221 in Ib 25 N m I
36. o vatios cuando este se encuentre en funcionamiento continuamente Consulte la salida nominal en la tabla de especificaciones Antes de conectar y utilizar el generador calcule la potencia el ctrica que requieren los aparatos el ctricos en vatios Esta especificaci n de la potencia el ctrica figura normalmente en la etiqueta del fabricante en bombillas aparatos el ctricos motores etc La suma total requerida por estos aparatos no debe superar la potencia nominal del generador Los protectores de circuitos E y el interruptor de carga A detendr n le energ a de los recept culos protegidos C D F o G cuando se detecte la sobrecarga de un dispositivo el ctrico conectado o cuando el voltaje de salida de la CA se eleve para proteger al generador y a cualquier dispositivo el ctrico conectado Cuando ocurre una sobrecarga y se interrumpe la generaci n de corriente proceda del siguiente modo 1 Apague todos los dispositivos el ctricos conectados y pare el generador 2 Reduzca el vataje total de los dispositivos el ctricos conectados dentro de los l mites de aplicaci n 3 Compruebe si existe alguna obstrucci n en las zonas de entrada y salida de refrigeraci n por aire y en torno a la unidad de control Si encuentra alguna obstrucci n elim nela 4 Despu s de la comprobaci n vuelva a arrancar el generador Selector de voltaje si lo tiene Cuando el interruptor del selector de voltaje AE
37. ocedimientos de seguridad cuando manipule bater as con el fin de evitar los da os en los componentes el ctricos y la explosi n de las bater as Consulte la ficha de datos de seguridad del fabricante de la bater a acerca de los riesgos de seguridad del trabajo con bater as Consulte las instrucciones del fabricante de la bater a acerca de los procedimientos de carga mantenimiento de la bater a NOTA 37 590 01 Rev B NOTA La tensi n nominal de CC del generador es de 12 V El protector de circuitos de CC E se apagar autom ticamente si la corriente supera el valor nominal durante la carga de la bater a Ponga en marcha primero el generador y luego conecte el generador a la bater a para cargarla Antes de poner en marcha para cargar la bater a aseg rese de que el protector de circuitos de CC E se encuentre en la posici n RESET Si el protector de circuitos de CC E se vuelve a apagar deje de cargar la bater a inmediatamente y p ngase en contacto con un distribuidor m vil de Kohler No conecte una bater a regulada por v lvula Para cargar una bater a regulada por v lvula se necesita un cargador de bater a especial tensi n constante ESS NOTA NOTA No conecte ninguna carga a la bater a ni utilice el motor de arranque durante la carga Esto provoca el paso de una corriente alta a trav s del generador que quemar a la bobina NOTA Antes de cargar la bater a retire los cables positi
38. pados bien ventilados y lejos de chispas o llamas El combustible derramado podr a inflamarse si entra en contacto con las piezas calientes del motor o las chispas de encendido No utilice nunca gasolina como agente de limpieza No utilice nunca el generador bajo la lluvia o la nieve No toque nunca el genera dor con las manos mojadas ya que podr a producirse una descarga el ctrica A aovertencia Las piezas ca lientes pueden causar quema duras graves No toque el ge nerador durante el funcionamien to o inmediata mente despu s de pararse A AA A avvertencia Las piezas rotatorias 0 pueden causar lesiones graves ON Mant ngase alejado del generador cuando est en funcionamiento A avvertencia X Los arranques accidentales y pueden provocar lesiones graves O la muerte Antes de llevar a cabo trabajos de mantenimiento o reparaci n desconecte y a sle el cable de la buj a No ponga nunca el genera dor en funcionamiento con las protecciones t rmicas desmontadas No modifique el generador Coloque el generador en un lugar donde no lo vayan a tocar los peatones ni los ni os Aseg rese de transportar el generador por sus asas de transporte nicamente Para evitar lesiones man tenga las manos los pies el pelo y la ropa alejados de las piezas en movimiento No ponga nunca el genera dor en funcionamiento con las cubie
39. para obtener un mejor rendimiento Tambi n f ERE se puede utilizar otro aceite detergente de alta 1 aute la varilla de nivel llenado N limpie el calidad API American Petroleum Institute SJ o ne Recomendaciones de lubricante superior incluidos los aceites sint ticos Selec 2 Quite la varilla de nivel llenado N verifique cione la viscosidad en funci n de la temperatura el nivel de aceite El nivel debe estar en la del aire durante el funcionamiento como se parte superior del indicador en la varilla de muestra en la tabla que aparece a continuaci n nivel R 3 Si el nivel de aceite es m s bajo a ada 10W 30 aceite hasta el punto de desbordamiento del ER gt cuello de llenado TI 4 Vuelva a colocar la varilla de nivel llenado Sw30_ N y apriete firmemente F 20 0 20 32 40 50 60 80 100 2c 30 20 10 0 10 20 30 40 Cambio de aceite Cuando la cambiar la l mpara del aceite Y Comprobaci n del nivel de aceite se encienda presione restablecer AC y siga las instrucciones de mantenimiento Cambie el NOTA Para evitar las aver as y el desgaste aceite con el motor caliente excesivo del motor nunca ponga el oe motor en funcionamiento con un nivel 1 Limpie el area que rodea el tap n varilla de de aceite inferior o superior al _ llenado de aceite N y el tap n de drenaje M indicador de nivel de funcionamiento 2 Quite el tap n de drenaje M y el tap
40. paraci n Registre la informaci n del producto con el fin de consultarla para realizar pedidos de piezas o para obtener la cobertura de la garant a Especificaci n N mero de serie Fecha de compra 37 590 01 Rev B KohlerPower com Precauciones de seguridad A PELIGRO Un peligro que provoca la muerte lesiones graves o da os materiales considerables A ADVERTENCIA Un peligro que podr a provocar la muerte lesiones graves o da os materiales considerables A PRECAUCI N poca gravedad NOTA Se utiliza para notificar al personal sobre informaci n importante para la instalaci n el funcionamiento o el mantenimiento Un peligro que podr a provocar lesiones personales o da os materiales de Lea este manual con atenci n antes de utilizar esta m quina Este manual deber acompa ar a la m quina en caso de que esta se venda A ADVERTENCIA La explosi n del carburante puede provocar incendios y que maduras graves MMs No llene el 4 tanque de combustible con el motor en funcionamiento o caliente Ad Precauci n Las descargas el ctricas pueden provocar lesiones E No toque los cables con el generador en funcionamiento La gasolina es muy inflama ble y sus vapores pueden ha cer explosi n si se inflaman No reposte nunca mientras fuma ni cerca de una llama al descubierto Almacene la gasolina siempre en conte nedores homologados en locales desocu
41. parks or flames Spilled fuel could ignite if it comes in contact with hot parts or sparks from ignition Never use gasoline as a cleaning agent Never operate generator in rain or snow Never touch generator with wet hands or electrical shock may occur A WARNING Hot Parts can cause severe burns his Gy AAA Do not touch generator while operating or just after stopping A WARNING A WARNING 7 Accidental Starts can cause severe injury or death Disconnect and ground spark plug lead s gt before servicing Never operate generator with heat shields or guards removed Do not modify generator Place generator in a place where pedestrians or children are not likely to touch generator Be sure to carry generator only by its carrying handles Rotating Parts 0 can cause E severe injury Stay away while generator is in operation Keep hands feet hair and clothing away from all moving parts to prevent injury Never operate generator with covers shrouds or guards removed Before working on generator or equipment disable engine as follows 1 Disconnect spark plug lead s 2 Disconnect negative battery cable from battery Do not allow children to operate generator A CAUTION Hazardous Voltage Backfeed to utility system Eg can cause property damage severe injury or death Never
42. rical shock may occur A CAUTION Electrical Shock can cause injury Do not touch wires while generator is running NOTE This section refers to charging 12V batteries in other equipment like motor vehicles or off road vehicles No jump starting is possible Follow safety procedures when handling batteries to avoid damage to electrical components and battery explosions Refer to battery manufacturers safety data sheet on safety risks of working with batteries Refer to battery manufacturer s instruction on battery charging maintaining procedures Generator DC rated voltage is 12V DC circuit protector E will turn off automatically if current above rated flows during battery charging Start generator first then connect generator to battery for charging Before starting to charge battery ensure DC circuit protector E is in RESET position If DC circuit protector E turns off again stop charging battery immediately and contact a Kohler portable dealer Do not connect a VRLA valve regulated lead acid battery To charge a VRLA battery a special constant voltage battery charger is required Do nat connect any load to battery or use engine starter motor while charging This causes high current to flow through generator which will burn out coil NOTE NOTE NOTE NOTE NOTE Prior to charging battery remove positive and negative cables to battery 37 590 01 Rev B 1 Start
43. rtas revestimien tos t rmicos o protecciones desmontados 18 Antes de realizar cualquier trabajo en el generador o en el equipo desactive el motor como se indica a continuaci n 1 Desconec te los cables de las buj as 2 Desconecte el cable del polo negativo de la bater a No deje que los ni os manejen el generador Advertencia la Propuesta 65 de California El escape de motor de este producto contiene sustancias qui micas identificadas por el Estado de California como causantes de c ncer defectos de nacimiento u otros da os gen ticos Ad Precauci n Tensi n peligrosa La retroalimen taci n al sistema de suministro Es el ctrico puede causar da os materiales lesiones graves o la muerte No conecte nunca un gene rador port til directamente a la toma de un edificio Si el generador se va a utilizar para corriente auxiliar pida a un electricista autori zado y cualificado que instale un conmutador de transfe rencia autom tico para evitar la interconexi n accidental de las fuentes de alimenta ci n auxiliar y normal KohlerPower com 37 590 01 Rev B Etiquetas importantes en el generado 4 amp DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell as NEVER use inside a home Only use OUTSIDE and far or garage EVEN IF doors
44. so de aceite 5 Vuelva a instalar el elemento de espuma V en la base del filtro de aire W 6 Vuelva a instalar la tapa y fijela con el tornillo T Tubo del respirador Asegurese de que ambos extremos del respirador estan conectados adecuadamente 37 590 01 Rev B KohlerPower com Refrigeraci n por aire A ADVERTENCIA Las piezas calientes pueden causar quemaduras graves ates No toque el generador durante el funcionamiento o inmediatamente despu s de pararse No ponga nunca el generador en funcionamiento con las protecciones t rmicas desmontadas No modifique el generador Coloque el generador en un lugar donde no lo vayan a tocar los peatones ni los ni os Aseg rese de transportar el generador por sus asas de transporte nicamente Es esencial una refrigeraci n adecuada Para evitar el recalentamiento aseg rese de que las zonas de entrada y salida de refrigeraci n por aire est n limpias y libres de obstrucciones Evite rociar agua al haz de cables o a cualquier componente el ctrico Consulte el Programa de mantenimiento Terminal de masa La terminal de masa H conecta el cable de masa para evitar descargas el ctricas Cuando el dispositivo el ctrico est conectado a masa aseg rese de conectar a masa tambi n el generador Conecte a masa el generador conecte un cable de cobre de 6 AWG 10 mm a la conexi n a masa del generador y a una pica de tierra de acero galva
45. sources of supply When running speed of generating set has stabilized approximately 3 minutes 1 Check that circuit protectors E are pushed in Press if necessary N Connect appliances to electrical sockets C D amp G of generator w Maintenance Minder B shows number of hours that generator has worked Angle of Operation Do not operate this engine exceeding maximum angle of operation see specification table Engine damage could result from insufficient lubrication 37 590 01 Rev B KohlerPower com 5 Cable Selection Generator Socket Type 10A 16A 32A Recommended Ola Ola 0 Cable Cross E E E Section lt lt lt 2e 4 10 6 9 10 7 Length cde oae 10107 467251 Used jeg 10 7 16 5 35 2 1 This cable length is maximum permitted length and must not be exceeded Installation method cables on raceway or non drilled tablet Permitted drop in voltage 5 Multi core conductors Cable type PVC 70 C e g HO7RNF Ambient temperature 86 F 30 C ON OFF START Switch ON OFF START switch J controls ignition system ON Position Ignition circuit is switched on Engine can be started OFF Position Ignition circuit is switched off Engine will not run START Position Pressing and holding switch in START position will start engine with electric start if equipped 6 KohlerPower com Auto Idle When Auto Id
46. tness of connections and its general cleanliness Circuit Breaker Generating set s electrical circuit is protected by one or more magnetothermal differential or thermal cut out switches If an overload and or short circuit occurs supply of electrical energy may be cut If necessary replace circuit breaker A in generating set with circuit breakers with identical nominal ratings and specifications KohlerPower com 11 Clean Generating Set 1 Remove all dust and debris from around exhaust N Clean generating set particularly alternator and engine air inlets and outlets using a cloth and brush Check general condition of generating set and replace any faulty parts Transporting Generator Before transporting generator check that bolts are correctly tightened close fuel valve X and disconnect starter battery O Generator should be transported in its normal operating position never lay it on its side Ensure where generator it is to be stored or used is carefully prepared beforehand Repairs Service Parts We recommend that you use a Kohler portable dealer for all maintenance service and replacement parts for engine To find a Kohler portable dealer visit KohlerPower com or call 1 800 544 2444 U S and Canada Long term storage of your generator will require some preventative procedures to guard against deterioration NOTE Do not connect with any electrical devices unloaded operation I
47. tos de CC E saltar hacia afuera interrumpiendo el paso de corriente del recept culo de CC F cuando el dispositivo electr nico conectado al generador funcione con una corriente superior al valor nominal Para usar este equipo de nuevo presione el bot n del protector de circuitos de CC E Bater a del motor de arranque si la tiene Debido a que la bater a del motor de arranque O no requiere mantenimiento solo verifique la condici n y el ajuste de las conexiones y su limpieza general Interruptor de carga El circuito el ctrico del conjunto del generador est protegido por uno o m s interruptores magnetot rmicos diferenciales o de corte autom tico Si ocurre una sobrecarga y o un corto circuito es posible que se suspenda el suministro de energ a el ctrica Si es necesario reemplace el interruptor de carga A del conjunto generador con otros interruptores de potencial nominal y especificaciones id nticas Limpieza del conjunto del generador Quite el polvo y los residuos que hay alrededor del escape Limpie el conjunto del generador en particular las entradas y salidas del alternador y del motor con un pa o y un cepillo Revise las condiciones generales del conjunto del generador y reemplace cualquier pieza defectuosa N w 28 KohlerPower com Transportaci n del generador Antes de transportar el generador verifique que los pernos est n bien apretados cierre la v lv
48. trical sockets D amp G Ensure to turn main circuit breaker A to OFF position before using voltage selector AE switch to avoid accidentally damaging generator because of any connected load that may be drawing power from unit Voltage Selector Receptacle Power GFCI Receptacle Test Available Power 1 Start engine Switch PRO 5 2 NE Position Receptacle PRO 5 2 E 2 Press TEST button if functioning properly RESET button should pop out stopping 240V 120V 30A 30A 120V power to outl t OAV 120V 304 30A 120V 3 If GFCI operation is correct push RESET my button in If GFCI operates incorrectly GFCI 20A O 120V contact a Kohler portable dealer 240V 120V 30A 18 5A 240V Overload Capacity of Generator oy 120V 30A 18 5A 120V Never exceed rated load of generator in Amps GFCI 18 5A 120V and or Watts when it is running continuously See specifications table for rated outputs Before connecting and operating generator calculate electrical power required by electric appliances in Watts This electrical power rating is usually found on manufacturer s plate on bulbs electrical appliances motors etc Sum total of power required by these appliances should not exceed nominal power rating of generator 10 KohlerPower com 37 590 01 Rev B Battery Charging Using DC Receptacle if equipped Never operate generator in rain or snow Never touch generator with wet hands or elect
49. ue no haya fugas X A PRECAUCI N Las descargas el ctricas pueden provocar lesiones y No toque los cables con el generador en funcionamiento No utilice nunca el generador bajo la lluvia o la nieve No toque nunca el generador con las manos mojadas ya que podr a producirse una descarga el ctrica Cuando la cambiar la l mpara de la buj a Z se encienda presione restablecer AC y siga las instrucciones de mantenimiento Limpie el rebaje de la buj a Extraiga la buj a Q y sustit yala 1 Compruebe la separaci n de electrodos con una galga de espesores Para ajustar la separaci n consulte la tabla de especificaciones de ajuste 2 Instale la buj a Q en el cabezal del cilindro 3 Apriete la buj a Q a 27 N m 20 ft lb Filtro de aire NOTA El funcionamiento del motor con componentes del filtro de aire sueltos o da ados puede causar da os y desgaste prematuro Sustituya todos los componentes doblados o da ados Cuando la reemplazar la l mpara del filtro de aire AA se encienda presione restablecer AC y siga las instrucciones de mantenimiento 1 Desmonte el tornillo T y la tapa del filtro de aire U 2 Quite el elemento de espuma V de la base del filtro de aire W 3 Lave el elemento de espuma V con agua templada y detergente Acl relo y d jelo secar al aire 4 Lubrique ligeramente el elemento de espuma V con aceite nuevo para motor y escurra el exce
50. ueden causar lesiones graves Mant ngase alejado del motor cuando est en funcionamiento Para evitar lesiones mantenga las manos los pies el pelo y la ropa alejados de las piezas en movimiento No ponga nunca el motor en funcionamiento con las cubiertas revestimientos t rmicos o protecciones desmontados NOTA El interruptor de ralent autom tico J debe estar en la posici n OFF cuando se utilicen dispositivos el ctricos que precisen una elevada corriente de arranque como un compresor o una bomba sumergible El ralent autom tico controla la velocidad del motor seg n la carga conectada Los resultados son un mejor consumo de combustible y menos ruido NOTA El estrangulador no es necesario para arrancar un motor caliente Empuje la palanca del estrangulador P hasta su Ess posici n original 1 Gire el interruptor de carga A de CA a la posici n de OFF 2 Gire el ralent autom tico I a la posici n de OFF si lo tiene 3 Gire el combustible X a ON 4 Gire el motor a la posici n ON J y jale el cable o presione el bot n de arranque J para el arranque el ctrico 5 Mueva la palanca del estrangulador a P OFF despu s de que se caliente el motor Si el motor no arranca repita la operaci n hasta que arranque abriendo el estrangulador de forma gradual Arranque en tiempo fr o Utilice el aceite apropiado para la temperatura prevista Descon
51. ula del combustible X y desconecte la bater a del motor de arranque O Se debe transportar el generador en su posici n de funcionamiento normal nunca la coloque sobre su costado Aseg rese de que el lugar donde guardar y usar el generador se haya preparado cuidadosamente con anticipaci n Reparaciones Piezas de recambio Recomendamos que utilice un distribuidor m vil de Kohler para el mantenimiento la reparaci n o la sustituci n de piezas del motor Para encontrar un distribuidor m vil de Kohler visite KohlerPower com o llame al 1 800 544 2444 EE UU y Canad Almacenamiento El almacenamiento de larga duraci n de su generador requiere algunos procedimientos preventivos para protegerlo del deterioro NOTA No conecte con ning n dispositivo el ctrico funcionamiento sin carga Si el motor no se pone en funcionamiento durante 2 meses o m s siga el procedimiento siguiente 1 A ada el tratamiento de combustible Kohler PRO Series o equivalente al dep sito de combustible Arranque el motor durante 2 3 minutos para que el combustible se estabilice en el sistema de combustible la garant a no cubre los fallos provocados por combustible sin tratar Cambie el aceite con el motor a n caliente Extraiga la buj a Q y vierta aproximada mente 28 g 1 oz de aceite de motor en el cilindro Sustituya la buj a Q y arranque el motor lentamente para distribuir el aceite 3 Limpie el generador
52. unit 1 Place post sides together onto frame 2 Place 3 nuts into holes in 1 side 3 While holding together insert screws into other side and thread into nuts Torque to 221 in lb 25 N m Install Lift Kit Lifting Kit a 0 16 KohlerPower com gt NOTE A clamping device or an assistant to hold assembly while installing kit will make process easier Hand truck handle kit includes hand truck handle and mounting hardware 1 Position hand truck handle on unit aligning frame holes and handle holes 2 Place washer between handle and frame 3 While holding in this position install screws 4 Thread nuts to screws Torque to 4 in Ib 0 5 N m 5 Install release knob through frame Place washer and hitch pin on inside of assembly Install Isolator Kit Isolator Kit EE ee Isolator Kit includes 4 isolators and mounting hardware 1 Align isolator holes under holes of frame 2 While holding in this position install screws 3 Thread nuts to screws Torque to 221 in Ib 25 N m 37 590 01 Rev B KOHLER a PRO 5 2 PRO 5 2 E PRO 7 5 PRO 7 5 E Manual del Usuario del Generador D TE R E EPEA IMPORTANTE Lea atentamente todas las instrucciones y precauciones de seguridad antes de poner el equipo en funcionamiento Aseg rese de que el motor est parado y nivelado antes de realizar tareas de mantenimiento o re
53. upter protection Ground Fault Circuit Interrupter GFCI stops power to protected receptacles G if a ground fault electrical leak is detected If RESET button pops out equipment plugged into receptacle G may be faulty If this happens check equipment carefully If equipment appears to be in good condition press RESET button firmly until a click is heard This will restore power If RESET button pops out again unplug equipment immediately Contact a Kohler portable dealer before attempting to use it again N Circuit protectors E and circuit breaker A will stop power to protected receptacles C D F or G when an overload of a connected electrical device is detected or AC output voltage rises to protect generator and any connected electric devices When overload occurs and power generation stops proceed as follows 1 Turn off any connected electric devices and stop generator 2 Reduce total wattage of connected electric devices within application range 3 Check for blockages in cooling air inlet and outlet areas and around control unit If any blockages are found remove them 4 After checking restart generator Voltage Selector if equipped When voltage selector AE switch is in 120V 240V position 120V is supplied to all electrical sockets C D amp G and 240V is supplied to 240 120V 30A electrical socket C When voltage selector AE switch is in 120V position only 120V is supplied to elec
54. vo y negativo de la bater a 1 Ponga en marcha el generador 2 Presione el protector de circuitos de CC E 3 Conecte el cable rojo del cargador de bater a al terminal positivo de la bater a Conecte el cable negro del cargador de bater a al terminal negativo de la bater a No invierta estas posiciones Conecte el cable al recept culo de CC F L mites de alimentaci n de CC s lo carga de bater as de 12 V Esta fuente de alimentaci n est dise ada para cargar bater as de hasta 40 Ah semidescargadas No cargue bater as de capacidad superior a 40 Ah Bater a de 12 V El tiempo necesario para recargar una bater a depende del nivel de descarga de la bater a Cuando la gravedad espec fica de la bater a alcanza de 1 26 a 1 28 la carga ha concluido Durante la carga compruebe la gravedad espec fica de la bater a una vez cada hora El tiempo medio de carga de una bater a de 40 Ah semidescargada es de unas 5 horas Aseg rese de comprobar el nivel de l quido de la bater a antes de cargar KohlerPower com 27 Protector de circuitos de CC NOTA Reduzca la carga del dispositivo el ctrico conectado por debajo de la salida nominal especificada del generador si el protector de circuitos de CC E se apaga Si el protector de circuitos de CC E se vuelve a apagar deje de usar el dispositivo inmediatamente y p ngase en contacto con un distribuidor m vil de Kohler El bot n del protector de circui
55. y x plug lead s before servicing Safety is an obligation of owner Periodic inspection adjustment and lubrication will keep your generator in safest and most efficient condition possible Most important points of generator inspection adjustment and lubrication are explained on following pages Maintenance Schedule After first 5 Hours e Change oil Every 25 Hours or Annually e Check starter battery O Every 100 Hours or Annually e Clean low profile air cleaner element V e Change oil e Clean cooling areas e Replace spark plug Q and set gap Every 200 Hours e Check and adjust valve clearance when engine is cold Every 300 Hours e Replace low profile air cleaner element V e Check fuel filter AD and clean or replace if needed 1 Perform these procedures more frequently under severe dusty dirty conditions 2 Have a Kohler portable dealer perform this service P A 2 Remove oil fill dipstick N check oil level UNOS Level should be at top of indicator on dipstick We recommend use of Kohler oils for best N performance Other high quality detergent ate a n oils including synthetic of API American 3 rol iS iow add oil up to point of overflowing Petroleum Institute service class SJ or higher Wer NECK are acceptable Select viscosity based on air 4 Reinstall oil fill dipstick N and tighten temperature at time of operation as shown in securely table below