Home

! WARNING - Napoleon® Products

image

Contents

1. 9 SPRING 415 1226 05 26 14 20 ee 5 3 BRICKS AND BAFFLE INSTALLATION OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE CHIMNEY AND THE SURROUNDING ENCLOSURE With appliance and chimney installation completed move the bricks into place for your appliance as illustrated A Install the bottom bricks working from the back of the appliance forward B Before installing the back bricks loosen the screw holding the brick retainer and ensure that it has been moved forward Install the six bricks along the back wall by pivoting the bricks up under the brick retainer Re tighten the screw C Install the first two rows of side bricks as shown in the illustration below D Pivot the fibre baffles into place with the brick retainer edge down and toward the outside of the appliance Slide the top row of bricks into place to support the baffle The baffle must sit flat on the outside row of bricks as well as the flange on the manifold shield Push the baffle all the way to the rear of the firebox leaving a minimum of 1 25mm gap along the front This will allow flue gases to escape the firebox E Install the remaining bricks along the front opening as illustrated below NOTE Do not operate without the bricks baffle and manifold shield are not in position W415 1226 B 05 26 14 21 51 54 59 Firebricks
2. The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 841A 8 3 RUNAWAY CHIMNEY FIRE FIRE PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM THIS DAMAGE ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY Runaway fires be the result of three major factors Using incorrect fuel or small fuel pieces which would normally be used as kindling Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door Burning your appliance with the ash plug not securely seated SOLUTIONS Do not burn treated or processed wood coal charcoal coloured paper or cardboard Be careful not to over fire the appliance by leaving the door open too long after initial start up thermometer on the chimney connector and or appliance top helps Always operate the appliance with the ash plug properly installed IN CASE OF A CHIMNEY FIRE Have a well understood plan for evacuation and a place outside for everyone to meet Prepare to evacuate to ensure everyone s safety Close air control on appliance Call local fire department Have a fire extinguisher handy Contact local authorities for furt
3. La fabrication de chaque mod le varie La garantie s applique uniquement aux composants disponibles avec votre appareil CONDITIONS ET LIMITATIONS NAPOL ONO garantit ses produits contre les d fauts de fabrication l acheteur d origine seulement L enregistrement de la garantie n est pas n cessaire Fournissez simplement une preuve d achat ainsi que le mod le et le num ro de s rie afin d effectuer une r clamation de garantie L achat doit avoir t fait par l entremise d un d taillant NAPOLEON autoris et sous r serve des conditions et limitations suivantes La couverture de la garantie d bute partir de la date d installation originale Cette garantie du fabricant n est pas transf rable et ne peut tre prolong e ou tendue par aucun de nos repr sentants quelle qu en soit la raison L appareil bois doit tre install par un installateur ou un entrepreneur qualifi L installation doit tre faite conform ment aux instructions d installation incluses avec le produit et tous les codes d incendie et de construction locaux et nationaux Cette garantie limit e ne couvre pas les dommages caus s par un mauvais usage un manque d entretien un accident des alt rations des abus ou de la n gligence et l installation de pi ces d autres fabricants annulera cette garantie Cette garantie limit e ne couvre pas non plus les gratignures le bossellement la corrosion ou la d coloration caus e par une chaleur excessive
4. 6IN PO 152 mm D UN AUTRE APPARE BACK WALL M A PLACED EXTENDS 8 200mm B 455mm TO THE FRONT SUR uNe BE PROTECTION ACCORD DE CHEMIN E PAROI SIMPLE WALL CONNECTOR D UN CONDUIT DE MAISON MOBILE HOME 1400 S4 10IN PO 254 mm 16IN PO 406 mm 6IN PO 152 mm 152 mm 4IN PO 102 mm 4IN PO 102mm 16IN PO 406 mm 152 mm 4IN PO 102 mm MODELS 1400 AND S4 MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED STATES ONLY LE MODELES 1400 ET S4 NE PEUT TRE INSTALL QUE DANS UNE MAISON MOBILE AUX TATS UNIS SEULEMENT INS C BE INSPECTEZ FT LISTED SOLID FUEL BURNING FIREPLACE INSERT QUEMMENT DANS CERTAINES ENCASTR COMBUSTIBLE SOLIDE HOMOLOGUE S DES D P TS DE TESTED TO TEST SELON PEUVENT SE FORMER RAPIDEMENT ULC 5628 UL 1482 EPI 1402 SOUFFLERIE OPTIONNELLE EP 62 115V 60HZ 0 82A TENEZ LE CORDON LECTRIQUE LOIN DE L APPAREIL DANGER RISQUE DE SECOUSSE LECTRIQUE D BRANCHEZ AVANT CEILING PLAFOND DE PROC DER L ENTRETIEN ENCASTR INSTALLEZ ET UTILISEZ SEULEMENT DANS UN FOYER COMBUSTIBLE SOLIDE NE RETIREZ PAS DE MORTIER NI BRIQUES DU FOYER COMBUSTIBLE SOLIDE INSTALLEZ AVEC UNE GAINE CONFORME ET UNE PLAQUE DE RECOUVREMENT C AUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURN
5. burn rate with the handle fully out Inadequate draft may cause back puffing into the room through the and chimney connector points and may cause plugging of the chimney much draft cause an excessive temperature in the appliance glowing red appliance parts or chimney connectors or an uncontrollable burn which can lead to a chimney fire or permanent damage to the appliance Do not operate your appliance for longer than 30 minutes with the draft control on HIGH fully open FIRE EXTINGUISHERS SMOKE DETECTORS All homes with a solid fuel burning appliance should have at least one fire extinguisher in a central location known to all and at least one smoke detector in the room containing the appliance If it sounds an alarm correct the cause but do not de activate or relocate the smoke detector 91 1 W415 1226 B 05 26 14 2 7 3 LIGHTING 7 3 1 FLASH A flash fire is a small fire burned quickly when you don t need much heat After your kindling has caught load at least 3 pieces of wood stacked loosely Burn with the draft control fully open or closed only slightly Eum 7 93 1 7 3 2 EXTENDED FIRE Load your larger pieces of wood compactly packed close enough to prevent the flames from penetrating it completely After approximately 30 minutes depending on the size of the load close the draft control completely making sure that the fire
6. CENDRES DANS DES BOITES EN CARTON NE LES JETEZ PAS DANS LA COUR ET NE LES ENTREPOSEZ PAS DANS UN GARAGE SI VOUS UTILISEZ UN ASPIRATEUR POUR NETTOYER LES CENDRES ASSUREZ VOUS QUE CES DERNIERES SOIENT ENTIEREMENT REFROIDIES L UTILISATION D UN ASPIRATEUR POUR NETTOYER LES CENDRES CHAUDES POURRAIT OCCASIONNER UN INCENDIE DANS L ASPIRATEUR NE FAITES JANAIS FONCTIONNER L APPAREIL AVEC LE COUVERCLE DE LA GRILLE RETIRE SI APPLICABLE SI LE JOINT ENTRE L OUVERTURE LE COUVERCLE ET LA PORTE DE LA CHUTE CENDRE N EST PAS ETANCHE CELA ENTRAINERA UNE SURCHAUFFE POUVANT ENDOMMAGER L APPAREIL Laissez les cendres s accumuler sur une paisseur de deux ou trois pouces 50 8mm 76 2mm sur le plancher de la chambre de combustion elles ont tendance se consumer Une fois que le feu s est teint et que les cendres se sont refroidies enlevez toutes les cendres exc dentaires mais laissez une paisseur d un pouce 25 4mm sur le plancher de la chambre de combustion pour aider conserver p un lit de braises chaudes gt OUR OUVRIR ET TOURNER POUR FERMER TOURNER AUX DIRECTION OPPOSEES Pour utiliser votre tiroir cendres tirez la poign e de la chute lt cendres puis tournez la de 90 vers la gauche pour ouvrir lt gt Ratissez les exc dentaires dans le tiroir Fermez la chute cendres en vous assurant qu il ny a pas de braises ou d objets qui emp chent le
7. ET INSTALLATION DE LA PORTE Assurez vous de bien tenir la porte en tout temps NOTE Nous recommandons que deux personnes effectuent cette installation A Retirez le support de charni re inf rieure de la porte en enlevant la vis comme illustr ci dessous puis desserrez le support de charni re sup rieure de la porte B Soulevez la porte pour la d gager de la tige de la charni re C Placez d licatement la porte face vers le bas sur une surface douce d viter d gratignere la peinture D Suivez les instructions en sens inverse pour installer la porte SUPPORT DE CHARNIERE DE LA PORTE VIS DE CHARNIERE Tel II Al TALI 1 JU UP TJ AUA EM L E 8 SUPPORT DE CHARNI RE DE LA PORTE TIGE DE CHARNI RE 5 1a AJUSTEMENT DE LA PORTE A Desserrez les deux vis de charni re pour ajuster la position horizontale de la porte B Serrez les deux vis de charni re lorsque la porte est la position souhait e 8 51b AJUSTEMENT DU BOITIER DU BLOC DE LOQUET A Desserrez les deux vis du boitier du bloc de loquet B D placez le boitier vers le haut ou vers le bas jusqu ce que la poign e ait l angle d sir ASTUCE Un d placement du boitier logement vers le haut a pour r sultat e
8. ified in the U S by the National Firepl known to the State of California to cause cancer birth defects or other Fr en Institue amp NFI as NFI Woodburning Specialists or reproductive harm who are certified in Canada by CERTIFIED Wood Energy Technical WoodEnergy If the outside air feature of the stove is utilized should never tegen Training WETT experience shortage of combustion air If you choose not to utilize outside air and experience draft or smoking problems you may need to open a door or window www To ensure that the ash dump door is tightly closed allow the door to snap shut dislodging anything ashes or pieces of coal that be stuck in the opening W415 1226 B 05 26 14 8 2 5 For rating plate location see INSTALLATION OVERVIEW section This illustration is for reference only Refer to the rating plate on the appliance for accurate information NOTE The rating plate must remain with the appliance at all times It must not be removed W415 1226 B 05 26 14 RATING PLATE INFORMATION 653 Intertek Intertek 15982 9700539 WSL gg 4001657 NGZ Ir 4001658 W 4001659 WUSA INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AND LOCAL BUILDING CODES MINIMUM CEILING HEIGHT 7FT 2 13m HEARTH EXTENSION COMBUSTIBLE FLOOR PROTECTION IF INSTALLED ON A COMBUSTIBLE FLOOR UNIT MUS
9. 1 1 4 32 Thick FIREBRICK PART amp FIREBRICK PART DIMENSIONS sr PIMENSIONS 41 2 9 090 0001 090 0001 090 0015 114mm x 229mm 12 18 20 3 x 9 Molded W090 0002 W090 0002 W090 0002 6mm x 229 X X2 X 2 2 1 4 x 9 W090 0018 W090 0018 090 0018 57mm x 229 X1 X1 X1 1 3 4 x 4 3 4 W090 0216 W090 0216 W090 0216 2 64mm x 121mm X1 X1 1 4 1 2 x 4 1 2 W090 0003 N A W090 0003 2 1 2 x 4 1 2 W090 0016 W090 0016 W090 0016 114mm x 144mm X2 2 64mm x 114mm 1 1 1 3 x 9 W090 0166 W090 0166 W090 0166 J 1 1 2 x 4 1 2 W090 0017 W090 0017 W090 0017 76mm x 229mm X2 X X4 38mm x 114mm X1 X1 X1 4 1 2 x 9 Notched W090 0207 W090 0207 W090 0207 4 1 2 x 8 1 2 W090 0210 W090 0210 W090 0210 114mm x 229mm X1 X1 X1 114mm x 216mm X3 X3 X3 4 1 2 x 9 Notched W090 0208 W090 0208 W090 0208 114mm x 229mm X1 X1 X1 BRICK BRICK gt RETAINERS gt A RETAINERS Fibre Baffles W018 0078 X2 d Fibre Baffles 018 0077 X2 Fibre Baffles W018 0130 X2 W415 1226 B 05 26 14 22 5 4 ASH DRAWER ADJUSTMENT NOTE If ash drawer adjustment is necessary there are adjustment areas located on the sides and bottom of the ash drawer as illustrated below A Remove the ash drawer from the appliance by pressing the drawer disconnect lever down on the righ
10. CARE OF PLATED PARTS If the appliance is equipped with plated parts you must clean fingerprints or other marks from the plated surfaces before operating the appliance for the first time Use a glass cleaner or vinegar and towel to clean If not cleaned properly before operating for the first time the marks can cause permanent blemishes on the plating After the plating is cured the fingerprints and oils will not affect the finish and little maintenance is required just wipe clean as needed Prolonged high temperature burning with the door ajar may cause discolouration on plated parts NOTE The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed using a hair dryer or similar heat Source 6 1 W415 1226 B 05 26 14 33 8 9 WOOD THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY DO NOT BURN TREATED WOOD COAL CHARCOAL COLOURED PAPER CARDBOARD SOLVENTS OR GARBAGE THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE HIGHER EFFICIENCIES AND LOWER EMISSIONS GENERALLY RESULT WHEN BURNING AIR DRIED SEASONED HARDWOODS AS COMPARED TO SOFTWOODS OR TOO GREEN OR FRESHLY CUT HARDWOODS BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE DO N
11. dans la maison e Dautres appareils evacuent l air de la maison Les fen tres de la maison sont tanches ou la maison est bien scell e Le raccordement de la prise d air sur l ext rieur peut se faire par l arri re ou par la base du pi destal avec une prise d air ext rieur de 4 100 mm de diam tre disponible chez votre d taillant autoris Suivez les instructions de la section lt PRISE D AIR EXT RIEUR MAISON MOBILE 3 4 1 PRISE D AIR EXT RIEUR MAISON MOBILE Le raccordement de la prise d air de l appareil sur l ext rieur n est obligatoire que pour les maisons mobiles Le raccordement peut se faire par une ouverture dans le mur align e avec la plaque perfor e l arri re du pi destal ou par une ouverture dans le plancher align e avec l ouverture dans la base du pi destal Utilisez un ensemble de prise dair PLAQUE ext rieur Fixez le conduit d aluminium de 4 de diam tre en vasant l extr mit PERFOREE une fois que le conduit a t ins r dans l ouverture de 4 1 2 dans la base ou l arri re du pi destal Si la prise d air traverse le plancher l ouverture en arri re du pi destal doit tre recouverte d une plaque de m tal afin d emp cher l air froid de se r pandre dans la pi ce Une plaque de recouvrement est disponible chez votre d taillant Wolf Steel It e vitez de sectionner les solives de plancher les montants muraux les c bles lectriques ou les l ments de plomberie Pour pr
12. 5 PLAQU ES 72 8 9 BOIS 73 9 0 RECHANGES 74 10 0 GUIDE DE DEPANNAGE 76 11 0 GARANTIE 77 12 0 HISTORIQUE D ENTRETIEN 78 13 0 NOTES 79 NOTE Les changements autres que de nature editoriale sont denotes par une ligne verticale dans la W415 1226 B 05 27 14 43 1 0 VUE D ENSEMBLE DE L INSTALLATION Plaque d homologation voir la section INFORMATION SUR LA PLAQUE D HOMOLOGATION Porte voir les sections ENLEVEMENT ET INSTALLATION DE LA PORTE Soufflerie voir la section INSTALLATION DELA SOUFFLERIE OPTIONNEL Retour d air voir la section CONTR LE D AIR Poign e de porte voir la section INSTALLATION DE LA PORTE ET DE LA Tiroir cendres voir la DE PORTE section AJUSTEMENT DU TIROIR CENDRES gt Briques et d flecteurs voir la section INSTALLATION DES BRIQUES ET DES DEFLECTEURS gt W415 1226 B 05 27 14 x 44 2 0 INTRODUCTION CET APPAREIL EST CHAUD LORSQU IL FONCTIONNE ET PEUT CAUSER DE GRAVES BR LURES EN CAS DE CONTACT TOUTE MODIFICATION APPORT E CET APPAREIL OU AUX CONTR LES PEUT TRE DANGEREUX ET EST INTERDIT Ne faites pas fonctionner l appareil avant d avoir lu et compris les instructions d op ration Omettre d utiliser l appareil selon les instructions d op ration pourrait causer un incendie ou des blessures e Avant d installer cet appareil contactez les autorit s locales du b t
13. ex rideaux portes moins de 48 1219 2mm de la face vitr e du po le 67 1B D GAGEMENTS AUX MAT RIAUX COMBUSTIBLES N INSTALLEZ PAS L APPAREIL DANS UN ESPACE AYANT MOINS DE 7 PIEDS 2 1m DE HAUTEUR DU PLAFOND DE L ENCEINTE AU BAS DE L APPAREIL EXCLUANT LA HAUTEUR DE LA BASE DE PROTECTION MUR ARRIERE CONDUIT DE RACCORDEMENT A CONDUIT DE RACCORDEMENT PAROI SIMPLE PAROI DOUBLE MUR DE C T A 16 16 22 16 16 22 MUR ARRIERE MUR LAT RAL MUR LATERAL PARALLELE ET EN COIN 406mm 406mm 559mm MUR DE C T LA 21 21 21 BUSE 533mm 533mm 533mm MUR ARRIERE C 10 12 12 406mm 19 483mm 406mm 19 483mm 6 152mm 152mm 559mm 19 483mm 12 254 305mm 305mm 305mm S MUR ARRIERE LA 13 16 5 16 5 16 5 419 419mm 229mm 229mm Ee BUSE D 330mm 419mm COIN E 6 6 8 2 8 152 152 203 51mm 102mm 203mm PLAFOND F 84 84 84 84 84 84 2134mm 2134mm 2134mm 2134mm 2134mm 2134mm Tous les d gagements peuvent tre r duits lorsqu une protection acceptable par les autorit s locales est utilis e Les installations avec des d gagements r duits doivent se conformer aux normes NFPA211 ou CAN CSA B365 W415 1226 B 05 27 14 50 3 3 3 4 PROTECTION DU PLANCHER PROTECTEUR DES BRA
14. il est possible d obstruer la chemin e d un appareil combustible solide en quelques jours si l appareil br le lentement et que la chemin e est froide NOTE Les utilisateurs qui font toujours des feux chauds auront rarement d importantes accumulations de cr osote dans la chemin e Lors du nettoyage de la chemin e certains l ments doivent tre consid r s Les outils appropri s doivent etre utilis s incluant une brosse sp cialement concue pour le de la Les conduits de raccordement le registre et la chemin e doivent etre nettoy s La chambre de combustion et les d flecteurs doivent etre nettoy s au besoin La chemin e doit etre inspectee et reparee au besoin de pr f rence par un ramoneur ou un macon qualifi T_OY SYI I 86 1 8 5 REMPLACEMENT DE LA VITRE N UTILISEZ PAS DE MAT RIAUX DE SUBSTITUTION LA VITRE PEUT ETRE CHAUDE NE TOUCHEZ PAS LA VITRE JUSQU A CE QU ELLE AIT REFROIDI USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES D BRIS DE VERREOU DES COMPOSANTS ENDOMMAGES ASSUREZ VOUS D ASPIRER TOUS LES DEBRIS DEVERRE L INTERIEUR DE L APPAREIL AVANT DE LE FAIRE FONCTIONNER NE FRAPPEZ PAS NE CLAQUEZ PAS ET N GRATIGNEZ PAS LA PORTE VITR E NE FAITES PAS FONCTIONNER L APPAREIL LORSQUE LA PORTE VITREE EST ENLEVEE FISSUREE BRISEE OU EGRATIGNEE 56 2 Quand l appareil est refroidit enlever la porte voir la section lt ENLEV
15. 8 9 BOIS CET APPAREIL T CON U POUR BRULER DU BOIS NATUREL UNIQUEMENT NE BRULEZ PAS DE BOIS TRAIT S DE CHARBON DE BOIS DE CHARBON DE PAPIERS DE COULEUR DE CARTONS DE SOLVANTS NI DE D CHETS CET APPAREIL N A PAS T TEST AVEC UN ENSEMBLE DE BUCHES GAZ NON VENTIL ES AFIN DE R DUIRE LE RISQUE D INCENDIE OU DE BLESSURE N INSTALLEZ PAS D ENSEMBLE DE BUCHES GAZ NON VENTIL ES DANS CET APPAREIL VOUS OBTENEZ UNE MEILLEURE EFFICACIT ET DES MISSIONS PLUS FAIBLES AVEC DU BOIS DUR S CH L AIR QU AVEC DU BOIS R SINEUX OU VERT OU DES BOIS DURS FRA CHEMENT COUP S BR LER DU BOIS VERT OU HUMIDE PEUT CAUSER DES ACCUMULATIONS EXCESSIVES DE CR OSOTE LORSQU ALLUM E ELLE PEUT CAUSER UN FEU DE CHEMIN E ET UN INCENDIE GRAVE POURRAIT S ENSUIVRE N ENTREPOSEZ PAS LE BOIS L INT RIEUR DES D GAGEMENTS DE L APPAREIL OU DANS L ESPACE REQUIS POUR LE RAVITAILLEMENT OU L ENL VEMENT DES CENDRES Lorsque vous chargez l appareil assurez vous que les d flecteurs en fibre dans le haut de l appareil ne se d placent pas Pour assurer une efficacit maximale lorsque l appareil est r chauff remplissez le avec du bois jusqu au haut de la porte de chargement et br lez en r glant feu moyen bas Des briques presque enti rement blanches et une vitre presque enti rement propre sont de bons indicateurs que votre appareil fonctionne efficacement Lorsque vous ne br lez que quelques b ches l appareil ne produira pas assez de chal
16. Close Bon the ash well making sure that no coals or foreign objects DIRECTION preventing the ash plug or well door from closing This creates a fire hazard that may result in a house chimney fire internal damage to the stove or discoloration to the gold plated door plated finishes are not covered by the warranty To ensure that the ash well is fully closed allow the door to snap shut dislodging anything that may be stuck at the opening NOTE ALWAYS ENSURE THE ASH PAN IS CONPLETELY COOL PRIOR TO REMOVING IT FROM THE ASH DRAWER Pullthe ash drawer forward to open this gains access to the ash pan Remove the ash pan by lifting it up and to the left or right side of the ash drawer Temporarily place the ash pan on a non combustible surface and close the ash pan lid Remove the ash pan and safely dispose of the ashes Before reinstalling the ash pan ensure that the ash pan lid is OPEN Place the ash pan into the ash drawer and then close the ash drawer NEVER OPERATE YOUR STOVE WITH THE ASH WELL IN AN OPEN OR AJAR POSITION W415 1226 B 05 26 14 29 8 2 CREOSOTE FORMATION AND REMOVAL When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cooler chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire
17. FE 1 jola st 10 0 GUIDE DE DEPANNAGE LORSQUE VOUS V RIFIEZ DES CONNEXIONS QUE VOUS INSTALLEZ DES FILS DE D RIVATION POUR EFFECTUER DES TESTS UNIQUEMENT O QUE VOUS REMPLACEZ DES COMPOSANTS D BRANCHEZ L APPAREIL DU R CEPTACLE AFIN D VITER LES CHOCS LECTRIQUES OU DES DOMMAGES AUX COMPOSANTS PROBLEME Le feu ne s allume pas Pr sence de fum e lorsque la porte est ouverte Une odeur se d gage de l appareil L appareil ne devient pas suffisamment chaud Le bois br le trop rapidement Vitre sale La soufflerie ne fonctionne pas Le loquet de porte est coincees W415 1226 05 27 14 SOLUTIONS Pas assez de bois d allumage de papier Ajoutez en Pas assez d air Assurez vous que le contr le d air est compl tement ouvert Blocage d air froid Brulez un morceau de papier journal pour cr er un tirage Utilisez du bois bien sec Conduit obstru Inspectez la chemin e Blocage d air froid Br lez un morceau de papier journal pour cr er un tirage Tirage insuffisant Ajoutez des conduits Laissez l air se stabiliser avant d ouvrir la porte Assurez vous que les d flecteurs sont bien positionn s Pression n gative Ouvrez une fen tre situ e pr s de l appareil Cuisson de la peinture Voir la section INSTRUCTIONS G N RALES Le bois est trop humide Tirage insuffisant Ajoutez des conduits Pas assez d air Assurez vous que le contr le d air est c
18. FT 1m 8 10 FT 3m wal 7 MN TO NEAREST i ROOFLIN I LESS THAN 10 FEET 10 FT 3m _ gt OR MORE 8 1 2 FT 0 6m FT 1m MIN MIN UI n FLAT i WALL W415 1226 B 05 27 14 4 1 3 TYPIQUE ATRAVERS LE PLAFOND Mettez l appareil en place le centre de la buse de fa on pas avoir couper les solives Utilisez un fil plomb pour aligner le centre de la puse D coupez et charpentez une ouverture dans le plafond de fa on fournir un d gagement de 2 50 8mm entre la chemin e et les mat riaux combustibles Ne remplissez cet espace avec aucun type de mat riau Fixez des entretoises entre les solives pour assurer lt gt un support additionnel Pour tout plancher i ou plafond travers s par la chemin e des z LA fix s ENTRETOISES 47 espaceurs coupe feu doivent etre fix s la base de chaque ouverture charpent e Si la chemin e traverse le grenier un cran de protection pour chevrons est requis 1 Tenez un fil plomb partir du dessous ESPACEUR COUPE FEU du toit pour d terminer doit se lt FACE INFERIEURE DES trouver l ouverture du toit D coupez et SOLIVES charpentez une ouverture dans le toit tout en conservant le d gagement de 2 50 8mm FR NOTE La chemin e doit tre support e au plafond ou au toit afin que son poids ne repose
19. Ibs 65 8kg 114 55 52kg IDEAL WOOD LENGTH 12 305mm 16 406 4mm 21 533mm WHEN END LOADED FIREBOX CHAMBER 13 1 2 x18 x12 18 18 12 22 1 2 x18 x12 343mm 457 2mm 457 2mm x 457 2mm 572mm x 457 2mm x 304 8mm x 304 8mm 304 8mm Figures will vary considerably with individual conditions Wolf Steel Ltd estimated realistic BTU h with hardwood logs and regular refueling 2 2 GENERAL INSTRUCTIONS ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH LOCAL CODES IN THE ABSENCE OF LOCAL CODES USE THE CURRENT CSA22 1 CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI NFPA NO 70 IN THE UNITED STATES THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE PREVENT INJURY DO NOT INSTALL A OR UNVENTED GAS LOG SET INTO THE APPLIANCE BURNING YOUR UNIT WITH THE ASH DUMP DOOR OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN DISCOLOURATION TO THE GOLD PLATED DOOR INTERNAL DAMAGE TO THE APPLIANCE OR HOUSE CHIMNEY FIRE DO NOT CONNECT THIS APPLIANCE TO CHIMNEY FLUE SERVING ANOTHER APPLIANCE THIS APPLIANCE AND IT S COMPONENTS ARE DESIGNED BE INSTALLED AND OPERATED AS SYSTEM ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS WILL VOID THE LISTING AND MAY VOID THE PRODUCT WARRANTY IT MAY ALSO CREA
20. Ne br lez pas de bois trait s de charbon de bois de charbon de papiers de couleur de cartons de solvants ou de d chets e Br lez le bois directement sur les briques r fractaires N utilisez pas un chenet et n essayez pas de sur lever le feu de quelque mani re e Nerangez pas de bois l int rieur des d gagements prescrits ou l int rieur de la zone n cessaire pour proc der au ravitaillement ou l enl vement des cendres e cendres doivent tre mises dans un contenant m tallique avec un couvercle herm tique et d pos sur une surface incombustible suffisamment loign de la maison ou de toute structure jusqu ce qu elles soient compl tement refroidies e Assurez vous de respecter les d gagements aux mat riaux combustibles lorsque vous installez un manteau ou des tablettes au dessus de l appareil Les temp ratures lev es sur le mur ou de l air au dessus de l appareil peuvent faire fondre d colorer ou endommager les d corations les t l viseurs ou autres composants lectroniques 3 17D W415 1226 B 05 27 14 45 2 1 DIMENSIONS FF 324mm S1 ILLUSTR 324mm 73 8 187mm 59 ILLUSTRE W415 1226 B 05 27 14 46 2 3 SPECIFICATIONS SPECIFICATIONS 8 s 89 56 139 93 186 93 325 POIDS SANS BRIQUES 215 Ibs 98kg 250 1 5 113kg 285 Ibs 129kg POIDS DES BRIQUES 110 Ibs 50kg 145 55 66kg 114 Ibs 52kg LONGU
21. PEUT CAUSER DES REFOULEMENTS DE FUM E OU UNE INCAPACIT MAINTENIR UN FEU LES REFOULEMENTS DE FUM E PEUVENT AUSSI DECLENCHER LES DETECTEURS DE FUM E UNE PRESSION N GATIVE DANS LA MAISON POURRAIT NUIRE AU RENDEMENT DE L APPAREIL _ AFIN D EVITER TOUT CONTACT AVEC DE L ISOLANT QUI S AFFAISSE L APPAREIL PAS ETRE INSTALLE CONTRE UN COUPE VAPEUR OU DE L ISOLANT A DECOUVERT UNE SURCHAUFFE LOCALISEE PEUT SURVENIR ET UN INCENDIE POURRAIT S ENSUIVRE N UTILISEZ PAS DE COMPROMIS DE FORTUNE LORS DE L INSTALLATION N OBSTRUEZ PAS ENTIEREMENT NI PARTIELLEMENT LES OUVERTURES D AIR LES GRILLES OU LES PERSIENNES N AJOUTEZ PAS DE HOTTE GARDEZ VOS OUTILS MAIN EN BON TAT AFF TEZ LES TRANCHANTS ET ASSUREZ VOUS QUE LES MANCHES SONT SOLIDES EN TOUT TEMPS CONSERVEZ L ESPACE VIDE MINIMAL REQUIS L ENCEINTE AFIN DE PR VENIR LES INCENDIES 68 3A W415 1226 B 05 27 14 52 4 1 CHEMIN E NE JAMAIS INSTALLER UN CONDUIT DE RACCORDEMENT A PAROI SINPLE DANS UNE ENCEINTE LES TEMP RATURES PLUS LEV ES DE CE CONDUIT PEUVENT IRRADIER SUFFISAMMENT DE CHALEUR AUX MATERIAUX COMBUSTIBLES POUR CAUSER UN INCENDIE NE RACCORDEZ PAS CET APPAREIL AU CONDUIT D UNE CHEMINEE DESSERVANT UN AUTRE APPAREIL POUR EVITER LE RISQUE D INCENDIE VOUS DEVEZ SUIVRE TOUTES LES INSTRUCTIONS LA LETTRE INCLUANT LES D GAGEMENTS ENTRE LE SYST ME DE CONDUITS ET L ENCEINTE AFIN DE PROT GER LES 5 EXPOS ES AUX INTEMP RIES CONT
22. and bricks H To reinstall the rear and side shields refer to steps A and B of the removal instructions NOTE PUSH THE BAFFLE ALL THE WAY TO THE REAR OF THE FIREBOX LEAVING A NINIMUM OF 1 25 4mm GAP ALONG THE FRONT THIS WILL ALLOW FLUE GASES TO PROPERLY ESCAPE THE FIREBOX W415 1226 B 05 26 14 32 8 7 8 8 CARE GLASS If the glass is not kept clean permanent discolouration and or blemishes may result Normally a hot fire will clean the glass The most common reasons for dirty glass include not using GLASS WILL sufficient fuel to get the appliance thoroughly hot using green CAUSE BURNS or wet wood closing the draft so far that there is insufficient air DO NOT TOUCH GLASS for complete combustion UNTIL COOLED If it is necessary to clean the glass buff lightly with a clean dry NEVER ALLOW CHILDREN cloth and non abrasive cleaner TO TOUCH GLASS DO NOT CLEAN GLASS WHEN HOT Clean the glass after the first 10 hours of operation with a recommended appliance glass cleaner Thereafter clean as required The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently NEVER FORCE IT SHUT If the glass should ever crack or break while the fire is burning do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced available from your Authorized dealer DO NOT SUBSTITUTE MATERIALS 5 3
23. chambre de combustion est trop basse 87 1 415 1226 05 27 14 74 9 0 RECHANGES Contactez votre d taillant ou le fabricant pour les questions concernant les prix et la disponibilit des pi ces de rechange Normalement toutes les pi ces peuvent tre command es chez votre d taillant autoris POUR REMPLACEMENT DE PIECE SOUS GARANTIE UNE DE LA FACTURE ORIGI NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE Lorsque vous commandez des pi ces donnez toujours l information suivante e Mod le et num ro de s rie de l appareil e Date d installation de l appareil OMETTRE DE POSITIONNER LES PIECES e Num ro de la CONFORMEMENT AU MANUEL OU D UTILISER e Description de la pi ce UNIQUEMENT DES PIECES SP CIFIQUEMENT e Fini APPROUVEES POUR CET APPAREIL PEUT IDENTIFIE LES ARTICLES QUI NE SONT PAS CAUSER DES DOMMAGES MAT RIELS ILLUSTRES POUR PLUS D INFORMATION CONTACTEZ VOTRE DETAILLANT AUTORISE OU DES BLESSURES CORPORELLES 41 1 COMPOSANTS mers si 5 Ts 66655 woo woo aoc fe woo messonnPoGN E o CS wo W415 1226 B 05 27 14 19 LL e 2 ACCESSORIES LLI el a x x gt 1 212 u 2 lt 5 2 oc m P E
24. damaged incomplete or substitute components Risk of cuts and abrasions Wear protective gloves and safety glasses during installation Sheet metal edges may be sharp e Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they in the same room as the appliance Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces e Clothing or other flammable material should not be placed on or near the appliance Objects placed in front of the appliance must be kept a minimum of 48 1219 2mm away from the front face of the appliance e Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies e Ensure you have incorporated adequate safety measure to protect infants toddlers from touching hot surfaces e Even after the appliance is out the glass and or screen will remain hot for an extended period of time e Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces These screens and guards must be fastened to
25. des produits d entretien chimiques et abrasifs ou l caillage des pi ces en porcelaine maill e le bris de tout composant de ventilation utilis dans l installation de l appareil Au cours de la premi re ann e seulement cette garantie s tend la r paration ou au remplacement des pi ces garanties dont les mat riaux ou la fabrication sont d fectueux sous condition que le produit ait t utilis conform ment aux instructions de fonctionnement et dans des conditions normales Apr s la premi re ann e concernant cette Garantie Vie Limit e du Pr sident NAPOL ONG peut sa discr tion se lib rer enti rement de toutes obligations en ce qui concerne cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie qui est d fectueuse Apr s la premi re ann e NAPOL ONG ne sera pas responsable de l installation de la main d oeuvre ou autres co ts ou d penses relatives la r installation d une pi ce garantie et de telles d penses ne sont pas couvertes par cette garantie Nonobstant toutes les dispositions contenues dans cette Garantie Vie Limit e du Pr sident la responsabilit de NAPOLEON sous cette garantie est d finie comme ci dessus et elle ne s tendra aucun dommage accidentel cons cutif ou indirect Cette garantie d finit l obligation et la responsabilit de NAPOL ONG en ce qui concerne l appareil bois NAPOL ONG Toute autre garantie nonc e ou implicite en ce qui
26. from the rear hole travels up the back in the secondary air housing to the manifold located at the top and shoots out laterally to oxidize the gases below the smoke exit The combustion chamber is lined with high temperature firebrick on 2 sides the back and across the bottom with a layer of fibre baffles at the top to maintain a high temperature in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned The stove sides and back are shielded to direct the heat upwards and forwards into the room CERAMIC GLASS AIR CONTROL CLOSED OPEN COMBUSTION AIR INTAKE Be sure to provide sufficient combustion air There are many other appliances in your home competing for air such as a kitchen range hood forced air heating devices or a bathroom exhaust fan Expansion contraction noises during heating up and cooling down cycles are normal and to be expected After extended periods of non operation such as following a vacation or a warm weather season the appliance may emit a slight odour for a few hours This is caused by dust particles on the firebox burning off Open a window to sufficiently ventilate the room CALIFORNIA PROP 65 WARNING NATIONAL We suggest that our woodburning hearth products FIREPLACE Use of this product may produce smoke which contains chemicals INSTITUTE installed and serviced by professionals who
27. is not extinguished DO NOT OVERFIRE THE APPLIANCE Overfiring can occur by A Burning large amounts of smaller wood pieces such as furniture scraps skids or treated wood B Vigorously burning large loads of wood with the draft control on HIGH fully open for long periods of time one or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door 82 1 7 4 SMOKING properly installed appliance should not smoke If yours does check the following Has the chimney had time to get hot Is the smoke passage blocked anywhere in the appliance chimney connector or chimney Is the room too airtight and the air intake not connected to the outside Try with a window partly open Is the smoke flow impeded by too long a horizontal pipe or too many bends Is it a weak draft perhaps caused by a leaky a cold outside chimney too large a diameter of a chimney too short a chimney or a chimney too close to trees or a higher roof 83 1 W415 1226 B 05 26 14 28 8 0 8 1 TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE MAY SERVICE UNTIL APPLIANCE HAS COOLED DO NOT USE ABRASIVE CLEANERS Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established If accumulation is excessive disconnect th
28. pas sur l appareil et son installation doit tre conforme aux instructions de son fabricant TERMINAISON CONSERVER 2 50 8mm DE DEGAGEMENT SOLIN DE TOIT COLLET DE SOLIN TOIT S INSOLANT 00505 gt lt MUR COMBUSTIBLE PROTECTION 00 ZN LLL LL LLL LLL I 1I 11211 PA qq CHIMINEE HOMOLOGU E CHIMIN E D GAGEMENT HOMOLOGUEE RECOMMANDE em ds WAN X SUPPORT CONDUIT CONDUIT DE LE POELE RACCORDEMENT 60 1B W415 1226 05 27 14 56 4 1 4 INSTALLATION TYPIQUE TRAVERS UN MUR Si possible l installation des conduits de raccordement doit pas passer travers un mur combustible S il faut absolument passer travers un mur combustible consultez votre inspecteur en b timent avant de proc der Consultez aussi le fabricant des conduits de raccordement pour connaitre toutes les exigences particuli res Consultez votre d taillant pour obtenir les composants de raccordement muraux dont vous auriez besoin N utilisez que les pi ces qui ont t test es et certifi es pour des installations travers un mur FR TERMINAISON CONSERVER UN TOIT D GAGEMENT DE 2 50 8mm TRAVERS L AVANT TOIT CHIMIN E MUR EXT RIEUR HOMOLOGUEE COMBUSTIBLE COLLET DE SOLIN SOLIN DE TOIT CONDUIT DE RACCORDEMENT RACCORD EN T ISOLE SUPPORT PLAFO
29. puisse rentrer CIRCULATION D AIR horizontalement de l arri re vers l avant dans l appareil Ceci facilite le chargement et il y aura moins de risque que le bois roule sur la vitre CIRCULATION D AIR Les b ches artificielles obtenues par la compression de fibre de bois 100 naturelle peuvent tre utilisees sans danger comme combustible N utilisez pas des b ches artificielles contenant des additifs comme de la paraffine de la cire des liants etc Ne brulez jamais plus de deux b ches artificielles la fois FAIRE NE PAS FAIRE e Faire un feu chaud e Retirer les cendres imm diatement Laissez les s accumuler e Utiliser du bois sec seulement sur une paisseur d au moins un pouce Une bonne couche Plusieurs morceaux de dimensions moyennes sont de cendres favorise une attis e qui br le mieux et qui dure pr f rables quelques gros morceaux plus longtemps e Nettoyer la chemin e r guli rement Bruler du bois humide e R alimenter fr quemment en utilisant des morceaux de Fermer la porte pr matur ment ou fermer le contr le de dimension moyenne combustion trop rapidement Bien ajuster le contr le de combustion pour une perfor Bruler un gros morceau de bois plut t que deux ou trois mance optimale morceaux plus petits de dimensions plus raisonnables e Br ler continuellement un r glage trop bas Si la vitre de la porte est constamment noircie cela signifie que la temp ra ture de la
30. qu il le faudra La vitre est tr s r sistante mais ne laissez pas de bois en combustion s appuyer contre elle Fermez toujours la porte doucement NE FORCEZ JAMAIS POUR LA FERMER Si la vitre devait fissurer pendant que le feu br le n ouvrez pas la porte jusqu ce que le feu s teigne et n utilisez pas l appareil jusqu ce que la vitre ait t remplac e par une nouvelle disponible chez votre d taillant autoris N UTILISEZ PAS DE MATERIAUX SUBSTITUTS 5 3 SOINS DES 5 PLAQU ES Si l appareil est muni de pi ces plaqu es vous devez enlever toutes traces de doigts ou autres marques des surfaces plaqu es avant d allumer l appareil pour la premi re fois Utilisez un nettoyant vitres ou du vinaigre et un linge pour nettoyer Si la surface plaqu e n est pas bien nettoy e avant le premier allumage de l appareil elle risque de rester marqu e en permanence Une fois que la surface plaqu e aura chauff les traces de doigts et le gras n affecteront plus la surface et tr s peu d entretien sera requis vous n aurez qu l essuyer au besoin Une combustion prolong e haute temp rature avec la porte ouverte peut causer une d coloration des pi ces plaqu es NOTE L emballage de protection sur les pi ces plaqu es s enl ve mieux lorsque l assemblage est temp rature ambiante ou lorsqu il est chauff avec un s choir cheveux ou une autre source de chaleur similaire T W415 1226 B 05 27 14 73
31. simple de 6 152 4mm de diam tre servant raccorder l appareil la chemin e doit tre install avec l extr mit gaufr e dans la buse de l appareil Ceci permettra la condensation qui se forme dans le conduit de raccordement de l appareil de s couler dans la chambre de combustion Chaque joint du conduit de raccordement doit tre x l aide d au moins trois vis autoperceuses Les recommandations suivantes pourraient tre utiles pour l installation du conduit de raccordement Le conduit de raccordement doit etre court et droit Pour une performance optimale toutes les courses horizontales devraient avoir une l vation minimale de 1 4 6 4mm par pied 0 9m et l extr mit sup rieure de la section devrait tre dirig e vers la chemin e d assurer un fonctionnement s curitaire et ad quat de l appareil consultez les instructions de la section lt INSTALLATION gt b Pour assurez un tirage ad quat la longueur horizontale du conduit ne doit jamais d passer 8 2 4m 10 pieds 3 1m Dans le cas d une installation verticale la longueur totale du conduit peut tre plus longue et le raccordement la chemin e peut etre fait sans probleme au niveau du plafond Un syst me de conduits ne devrait jamais avoir plus que deux coudes de 90 Avant d utiliser un coude de 90 installez une section verticale d au moins deux pieds 0 6m partir de la buse Le conduit ne doit pas passer dans un
32. the fire started Not enough kindling paper Add more Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Cold air blockage Burn a piece of paper to establish a draft Use dry seasoned wood Flue blockage Inspect chimney Smokes when door is Cold air blockage a piece of paper to establish a draft open Insufficient draft Add more pipe Let air stabilize before opening door Ensure baffles are positioned correctly Negative pressure Open a window near the appliance Appliance emits odour Paint curing See GENERAL INSTRUCTIONS section Stove doesn t burn hot Wood is too wet enough Insufficient draft Add more pipe Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Wood burns too fast Air control may need to be adjusted down Check to see ash plug is properly seated if equipped Check door gasket for adequate seal Wood may be extremely dry Dirty glass Air control may be closed too far Burn hotter smaller fires Use well seasoned wood Blower does not run Appliance may not be up to temperature Ensure blower has power Door latch is stiff Disassemble door latch and apply anti seize lubricant to the spring Reassemble W415 1226 B 05 26 14 3 11 0 WARRANTY NAPOLEON products are manufactured under the strict Standard of the world r
33. the floor e safety screen or guard removed for servicing must be replaced prior to operating the appliance e Under no circumstances should this appliance be modified e This appliance must not be connected to a chimney flue pipe servicing a separate solid fuel burning appliance e Do not operate the appliance with the glass door removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person e Do not strike or slam shut the appliance glass door e Only doors optional fronts certified with the unit are to be installed on the appliance e Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic bags these are not toys and should be kept away from children and infants e Ifthe appliance is not properly installed a house fire may result Do not expose the appliance to the elements ex rain etc and keep the appliance dry at all times Wet insulation will produce an odour when the appliance Is used chimney must be sound and free of cracks Clean your chimney a minimum of twice a year and as required e not start a fire with chemicals or fluids such as gasoline engine oil etc Your appliance requires periodic maintenance and cleaning Failure to maintain your appliance may lead to smoke spillage in your home Lower emissions generally result when burning air dried seasoned hardwoods as compared to soft
34. to prevent having to cut them Use a plumb bob to line up the center Cut and frame an opening in the ceiling to provide 2 50 8mm clearance between the outside of the chimney and any combustible material DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL Nail headers between the joist for extra Firestop spacers must be placed on the ALA bottom of each framed opening in any floor HEADERS or ceiling that the chimney passes through HEADERS If your chimney system is enclosed within the attic area a rafter radiation shield is required T Hold a plumb bob from the underside of FIRESTOP SPACER the roof to determine where the opening in UNDERSIDE OF JOIST the roof should be Cut and frame the roof opening to maintain proper 2 50 8mm clearances ep ERMINAL weight does not rest on the appliance and must comply with it s manufacturer s instructions MAINTAIN 77 2 50 8 STORM CLEARANCE COLLAR FLASHING NS CA SPECIFIED S ROOF ROY LISTED CHIMNEY INSULATION CHIMNEY SUPPORT SUPPORT ve STOVE CHIMNEY CONNECTOR COMBUSTIBLE FLOOR WALL PROTECTOR a PT EE ET TT RA 60 1 415 1226 05 26 14 16 4 1 4 TYPICAL THROUGH THE WALL If possible design the installation so that the connector does not pass through a combustible wall If during your installation you must pass through a combustible wal
35. un trop grand nombre de coudes 9 agit il d un tirage faible caus par une chemin e non herm tique une chemin e ext rieure froide un diam tre de chemin e trop grand une chemin e trop courte ou trop pr s des arbres ou d un toit plus lev Osv 83 1 W415 1226 B 05 27 14 68 8 0 ENTRETIEN COUPEZ L ALIMENTATION LECTRIQUE AVANT DE PROC DER L ENTRETIEN DE L APPAREIL L APPAREIL PEUT TRE CHAUD N EFFECTUEZ AUCUN ENTRETIEN JUSQU CE QUE L APPAREIL SOIT REFROIDI N UTILISEZ PAS DE NETTOYANTS ABRASIFS Afin de pr venir les accumulations de suie et de cr osote v rifiez votre chemin e et le conduit de raccorde ment toutes les semaines jusqu ce qu une fr quence de nettoyage s curitaire soit tablie Si les accumulations sont excessives d branchez l appareil et nettoyez le ainsi que la chemin e Vous pour riez faire appel aux services d un ramoneur professionnel pour nettoyer l appareil et la chemin e ils doivent tre nettoy s au moins une fois l an ou aussi souvent que n cessaire Inspecter les tuyaux d air secondaire Enlevez les d flecteurs en fibre et nettoyez au dessus une fois par ann e Remplacez les briques bris es Inspecter et remplacer toutes les joints d tanch it si n cessaire D monter nettoyer et lubrifier l assemblage du poign e du porte 8 1 DES CENDRES L LELIMINATION INCORRECTE DES CENDRES CAUSE DES INCENDIES NE JETEZ PAS LES
36. 0208 W090 0208 W090 0208 114mm x 229mm X1 X1 X SUPPORTS SUPPORTS S1 BRIQUES S4 BRIQUES D flecteur en Fibre D flecteur en Fibre 018 0078 X2 018 0077 X2 NOTE BRIQUES E ETF SONT ENTAILL ES SUPPORTS A BRIQUES 59 Deflecteur 018 0130 X2 415 1226 05 27 14 62 Ge 5 4 AJUSTEMENT DU TIROIR CENDRES NOTE Si un ajustement du tiroir cendres est n cessaire des zones d ajustement sont situ es sur les c t s et le fond du tiroir cendres comme illustr ci dessous A B Retirez le tiroir cendres de l appareil en appuyant vers le bas sur le levier de d connexion du tiroir du cote droit et vers le haut sur le levier du cote gauche puis tirez le tiroir cendres hors du pi destal Pour modifier l espacement entre le couvercle du tiroir cendres et le pi destal desserrez les vis d ajustement lat rales des deux c t s et positionnez la distance souhait e puis serrez les vis COUVERCLE DU TIROIR CENDRES FENTES VIS HEER DE D AJUSTEMENT gren D CONNEXION 5 DUTIROIR 0 lt PIEDESTAL IROIR A CENDRES BO TIER DU TIROIR A CENDRES NOTE Toujours s assurer que le cendrier est compl tement refroidi avant de le retirer du tiroir cendres W415 1226 B 05 27 14 63 W 6 0 INSTALLATIONS DES ENSEMBLES OP
37. ACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER MATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO OVERHEAT MAINTAIN A MINIMUM 2 50 8mm AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL TIMES EXCLUDING THE CHIMNEY CONNECTOR FAILURE TO MAINTAIN THIS 2 50 8mm AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE NEVER FILL THIS SPACE WITH ANY TYPE OF MATERIAL DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP STORM COLLAR AND TERMINATION CAP ARE PACKAGED WITH THESE PARTS MINIMUM CLEARANCE TO COMBUSTIBLES WILL VARY DEPENDING ON THEIR DESIGN DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIAL TO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING FLOOR AREA THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIGHT ABOVE THE APPLIANCE ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A MINIMUM OF 1 4 6 4mm PER FOOT meter AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREE SHEET METAL SCREWS EQUALLY SPACED AN UNINSULATED SMOKE PIPE SHALL NOT PASS THROUGH AN ATTIC ROOF SPACE CLOSET OR SIMILAR CONCEALED SPACE OR THROUGH A FLOOR CEILING WAL
38. ALLED INSTALL SUR UN PLANCHER EN ON A COMBUSTIBLE FLOOR COMBUSTIBLE L APPAREIL DOIT PRISE D AIR EXT RIEUR 111KT UN DEGAGEMENT UNIT MUSTBE PLACED ONA TRE PLACE SUR UNE PLAQUE 2 a NOTE N OT E Le ad Ue NON COMBUSTIBLE FLOOR PROTECTRICE INCOMBUSTIBLE OPEMINEE PEUTEIRE I h ti d t t PROTECTOR EXTENDING 18 S TENDANT SUR 18 455mm 1 455 IN FRONTAND 8 L AVANT ET 8 205mm L ARRI RE 0 0 IO n 0 res r avec 205mm TO THE SIDESAND ET SUR LES C T S BACK WALL WA BACK WATEMA 5 eu 3 BACK DE DIAM TRE appareil a tout temps II ne doit CHIMNEY TYPE MINIMUM 6 MINIMAL DE 6 152mm 5 152mm DIAMETER APPROUV E POUR USAGE APPROVED RESIDENTIAL R SIDENTIEL MAISON MOBILE 8 pas etre en lev TYPE FOR MOBILE HOME USE EMPLOYEZ UNE CHEMIN E E A CHIMNEY LISTED TO ULC HOMOLOGU E ULC 5629 AU S629 IN CANADA OR UL 103HT OU UL 103HT AUX IN THE USA TATS UNIS CHIMNEY CONNECTOR 6 RACCORD DE CHEMIN E 152mm DIAMETER MINIMUM DIAM TRE DE 6 152mm D ACIER 24 GAUGE STEEL MINIMUM CALIBRE 24 MINIMUM 18 CLEARANCE FROM 455mm DE D GAGEMENT MINIMAL HORIZONTAL CONNECTOR ENTRE LE RACCORD HORIZONTAL AND CEILING 18 455mm ET LE PLAFOND SFACE a SOUS D GAGEMENTS MINIMAUX AUX MAT RIAUX DE CHEMIN E PAROI SIMPLE SPECIAL METHODS ARE DES M THODES SP CIALES SONT REQU
39. APOLEONG will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger plated trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON NAPOLEONG reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim All parts replaced under the President s Limited Lifetime Warranty Policy are subject to a single claim During the first 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge From 10 years to life NAPOLEON will provide replacement parts at 50 of the current retail price All parts replaced under the warranty will be covered for a period of 90 days from the date of their installation The manufacturer may require that defective parts or products be returned or that digital pictures be provided to support the claim Returned products are to be shipped prepaid to the manufacturer for investigation If a product is found to be defectiv
40. BE HOT DO NOT TOUCH GLASS UNTIL COOLED CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED D P IS N V s soo 562 A When the appliance is cool remove the door from the appliance refer to the DOOR REMOVAL INSTALLATION section Place the door face down careful not to scratch the paint B Remove the 6 screws W570 0085 and the 6 glass retainers W500 0692 Remove the glass from the appliance C Replace door and or glass gaskets if necessary Secure into position using red silicone D Place the glass in position and re secure the 6 glass retainers do not D overtighten Refer to DOOR REMOVAL INSTALLATION section for proper door installation instructions IMPORTANT ENSURE THE lt gt RETAINER HAS THE DIMPLE gt FACING UPWARDS AS SHOWN DIMPLE NOTE For replacement glass see REPLACEMENTS section W415 1226 B 05 26 14 31 S 58 6 SECONDARY AIR TUBE REPLACEMENT At the end of each burning season inspect the secondary air tube for warping or deterioration Replace if necessary At this time also check that the door gasket is not worn or loose Replace with 1 2 12 7mm high density fibreglass rope if necessary NOT
41. E Do not operate appliance if the manifold airwash shield bricks or fibre baffle is deteriorated or missing To remove the secondary air tube follow these instructions A Remove the screws securing the side shields slide 2 5 them forward remove from the appliance B Remove the screws securing the rear shield then remove the shield from the appliance C Remove the rear bricks then remove the baffle D Remove the 2 nuts and bolts securing the secondary air tube in place for the S1 and 54 and 4 nuts and bolts on the 59 refer to the illustration below E Remove the secondary air tube 2 OUTSIDE ON S9 MODEL ONLY 4 To reinstall the secondary air tube follow these instructions SIDE VIEW A Locate the slot at the front of the firebox chamber as SECONDARY AIR TUBE illustrated NUT AND BOLT x2 B Insert the tab of the secondary air tube into the above mentioned slot and pivot the secondary air tube into SLOT position AIRWASH new gasket MUST be installed between the SHEILD secondary air tube and firebox Insert of the bolts to hold the secondary air tube place Working from the inside of the firebox take the second bolt and install it into position loosely secure the washer and nut F Remove the first bolt and reinstall as previously described in step E Fully tighten both nuts and bolts G Reinstall the baffles
42. EDESTAL INSTALLED Your appliance has been specifically designed over many months of research to meet the 1990 U S A EPA particulate emission standards been extensively tested in Canadian American laboratories This system is the most efficient simple trouble free we know works as follows The chimney vent system used on your wood burning appliance should be designed with the least amount of restriction possible to enable the exhaust products to easily flow through it Chimney vent systems that are too short or too long can also have an adverse affect on the flow of exhaust through it The wood burning appliance and chimney vent system also require a sufficient supply of combustion air not only to support the combustion in the combustion chamber but to replace the exhaust leaving it so it can flow freely up through the vent system and out into the atmosphere It is the correct balance of combustion air and the chimney vent system that will ensure the appliance provides you with its optimum performance Combustion air enters through two holes in the bottom which can be adjusted by a single air control Air from the front hole goes up on either side of the door into a FLUE GLASS preheating airwash located across the top and then down the window to feed the fire and also to ensure that the glass remains clean Air from this hole also feeds directly into the combustion chamber at hearth level Secondary air
43. EMENT INSTALLATION DE LA PORTE gt b Placer la porte sur une surface douce pour ne pas gratter la peinture B Enlever les 6 vis W570 0085 et puis les 6 supports du vitre W500 0692 Enlever la vitre de l appareil C Remplacer la joint d tanch it du porte et vitre si n cessaire Utilise le silicium rouge pout obtenir la joint d tanch it en place D Placer la vitre en position fixez avec les 6 supports de vitre ne serrez pas trop Referez vous la section ENLEVEMENT ET INSTALLATION DE LA PORTE pour les instructions d installation de la porte IMPORTANT ASSUREZ VOUS QUE LE BOSSE SUR LE SUPPORT DE VITRE FACE VERS L HAUT COMME ILLUSTR E BOSSE JOINT D TANCH IT DU PORTE NOTE Pour remplacer la vitre voir la section lt RECHANGES W415 1226 B 05 27 14 71 99 8 6 TUYAUX D AIR SECONDAIRE la fin de saison de chauffage inspectez le tuyau d alr secondaire pour d celer des signes de d formation ou de d t rioration Remplacez le si n cessaire moment v rifiez galement que le joint d tanch it de la porte n est pas us ou desserr Remplacez le par une corde de 75 po 12 7mm en fibre de verre haute densit si n cessaire NOTE Ne faites pas fonctionner l appareil si le collecteur l cran du syst me autonettoyant brique ou le d flecteur en fibre sont d t rior s ou manquants Pour enlever le tuyaux d air secondaire suivre
44. EUR ID ALE DES BUCHES 12 305mm 16 406mm 21 533mm CHAMBRE DU FOYER 13 1 2 X18 X12 18 X18 X12 22 1 2 18 12 343mm x 457mm x 457 457 572mm x 457mm x 305mm 305mm 305mm Ces donn es peuvent varier consid rablement selon les conditions particuli res BTU h r alistes estim s par Wolf Steel ltee avec des b ches de bois dur et un ravitaillement normal 2 2 INSTRUCTIONS G N RALES CET APPAREIL DOIT ETRE RACCORD LECTRIQUEMENT PAR UN LECTRICIEN QUALIFIE CONFORM MENT AUX CODES LOCAUX EN L ABSENCE DE CODES LOCAUX UTILISEZ LA VERSION COURANTE DU CODE CANADIEN DE L ELECTRICITE CSA C22 1 AU CANADA OU LE NATIONAL ELECTRICAL CODE ANSI NFPA 70 AUX TATS UNIS CET APPAREIL N A PAS ETE TEST AVEC UN ENSEMBLE DE B CHES GAZ VENTILEES OU NON VENTIL ES AFIN DE REDUIRE LE RISQUE D INCENDIE OU DE BLESSURE N INSTALLEZ PAS D ENSEMBLE DE BUCHES GAZ VENTIL ES OU NON VENTIL ES DANS APPAREIL FAIRE FONCTIONNER VOTRE APPAREIL AVEC LA CHUTE CENDRES OUVERTE OU ENTROUVERTE CONSTITUE UN RISQUE D INCENDIE QUI PEUT CAUSER UNE D COLORATION DE LA PORTE PLAQU E OR DES DOMMAGES INTERNES L APPAREIL OU UN FEU DE CHEMIN E CET APPAREIL NE DOIT PAS TRE RACCORD AU CONDUIT D UNE CHEMINEE DESSERVANT UN AUTRE APPAREIL APPAREIL ET SES COMPOSANTS SONT CONCUS POUR INSTALLES ET FONCTIONNER COMME UN SYSTEME TOUTE MODIFICATION OU SUBSTITUTION DE COMPOSANTS AUTRES QUE CELLES IND
45. G FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTRUCTIONS DU FABRICANT ET INSTALLATION INSPECTION IN YOUR AREA MODEL 1400 IS SUITABLE FOR USE AUX CODES LOCAUX DU BATIMENT iN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT 111KT HAUTEUR DE PLAFOND MINIMAL MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNECTOR MAY 2 13 REQUIRED BY THE AUTHORITY HAVING JURISDICTION PROLONGEMENT RENSEIGNEZ VOUS AUPRES DES AUTORIT S LOCALES DU B TIMENT ET DU D ATRE PROTECTION DU SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS PLANCHER COMBUSTIBLE SI lt INSTALLE SUR UN PLANCHER COMBUSTIBLE L APPAREIL ETRE PLACE SUR UNE PLAQUE PROTECTRICE INCOMBUSTIBLE S TENDANT SUR 18 455mm L AVANT 8 205mm L ARRI RE ET SUR LES C T S TYPE DE CHIMN E DIAMETRE MINIMAL DE 6 152mm APPROUV E POUR USAGE R SIDENTIEL MAISON MOBILE EMPLOYEZ UNE CHEMIN E HOMOLOGUEE ULC S629 AU CANADAOU UL 103HTAUX TATS UNIS RACCORD DE CHEMIN E DIAMETRE DE 6 152mm D ACIER DE CALIBRE 24 MINIMUM 18 455mm DE D GAGEMENT MINIMAL ENTRE LE RACCORD HORIZONTAL ET LE PLAFOND NE RIEN ENTREPOSER SOUS L APPAREIL DES M THODES SP CIALES SONT REQUISES LORSQU UNE CHEMIN E FROM HEATER DU PO LE TRAVERSE UN MUR OU UN RESIDENTIAL R SIDENTIEL PLAFOND VOIR LES INSTRUG 1400 54 TIONS ET LES CODES DU 305 16IN PO 406 mm B TIMENT 305mm 12IN PO 305 mm DE 152
46. INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE NEVER LEAVE CHILDREN OTHER AT RISK INDIVIDUALS WITH THE APPLIANCE POLE INSTALLATION AND QUALITY FIREPLACES OPERATING INSTRUCTIONS CERTIFIED UNDER U S ENVIRONMENTAL PROTECTION AGENCY E P A JULY 1990 40 C F R PART 60 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY D E Q PARTICULATE EMISSION STANDARDS BY THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS CSA B366 2 ULC 5627 UL 1482 51 54 amp 59 PEDESTAL MODELS SAFETY INFORMATION WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Improper installation adjustment alteration service or maintenance can cause injury or property damage bodily injury or even death Please read entire manual before you install and use your appliance This appliance has not been tested with an unvented gas log set To reduce risk of fire or injury do not install an unvented gas log set into the appliance This appliance can be very hot when burning Combustible materials such as firewood wet clothing etc placed too close can catch fire Children and pets must be kept from touching the appliance when it is hot HOT GLASS WILL CAUSE The chimney must be sound and free of cracks Before installing this un
47. IQU ES DANS LES INSTRUCTIONS D INSTALLATION AURONT POUR EFFET D ANNULER L HOMOLOGATION ET RISQUE D ANNULER LA GARANTIE CELA PEUT AUSSI CREER UNE INSTALLATION DANGEREUSE LISEZ BIEN TOUTES LES INSTRUCTIONS AVANT DE COMMENCER VOTRE INSTALLATION ET SUIVEZ LES A LA LETTRE 4 7 Avant d installer cet appareil contactez les autorit s locales en batiment ou le service des incendies et votre compagnie d assurance afin de vous conformer leurs directives De la fum e non toxique manera de l appareil lors du processus de cuisson de la peinture Ouvrez une fen tre proximit de l appareil pour aider dissiper la fum e Enlevez la poussi re ou les d bris sur le dessus de l appareil avant de l allumer car la peinture ramolirra pendant que l appareil se r chauffe et durcira pendant le processus de cuisson Pour cuire la peinture faites br ler l appareil feu mod r durant les quelques premiers allumages Pour empecher le joint d tanch it de coller l appareil lors de la cuisson de la peinture ouvrez la porte de l appareil toutes les 5 10 minutes Durant les deux premi res semaines faites bruler l appareil avec beaucoup de bois et ouvrez le controle de combustion au maximum pendant une heure pour permettre l appareil d liminer toute humidit dans l acier et les briques r fractaires La production de chaleur initiale sera r duite alors que l humidit est chass e de l appareil II sera n cessaire de fa
48. IRED WHEN PASSINGA REQUISES LORSQU UNE CHEMIN E HEATER DU PO LE CHIMNEY THROUGH A WALL TRAVERSE UN MUR OU UN RESIDENTIAL R SIDENTIEL OR CEILING SEE INSTRUC PLAFOND VOIR LES INSTRUC 1400 54 TIONS BUILDING CODES TIONS ET LES CODES DU 12IN PO 305 mm 16IN PO 406 mm DO NOT CONNECT THIS UNIT B TIMENT 12IN PO 305 mm 12IN PO 305 mm TO A CHIMNEY FLUE SERVING PAS RACCORDER ALA 6IN PO 152 mm 6IN PO 152 mm ANOTHER APPLIANCE F FUEL FOR USE WITH WOOD COMBUSTIBLE POUR USA ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD PAS DE CHENET FIRE DIRECTLY ON HEARTH WARNING RISK OF SMOKE PR PAREZ LE SPILLAGE OPERATE ONLY SUR L TRE WITH DOOR FULLY CLOSED REPLACE GLASS ONLY WITH CERAMIC GLASS DO NOT OVERFIRE IF MODELS 1400 AND 54 MAY BE INSTALLED INTO MOBILE HOME IN THE HEATER OR CHIMNEY UNITED STATES ONLY CONNECTORS GLOW YOU LE MODELES 1400 4 PEUT ETRE INSTALLE QUE DANS UNE MAISON ARE OVERFIRING INSPECT MOBILE AUX ETATS UNIS SEULEMENT AND CLEAN CHIMNEY FREQUENTLY UNDER USE CREOSOTE BUILD LISTED SOLID FUELBURNING FIREPLACE INSERT A MAY OCCUR RAPIDLY ENCASTR COMBUSTIBLE SOLIDE HOMOLOGU DES DEPOTS DE IF THE STOVE IS TO BE INSTALLED ON A CG BLE FLOOR IT MUST BE PLACED ON AN AP D NON COMBUSTIBLE HEARTH PAD THAT EXTENDS 8 229 455mm TO THE SI LE POELE EST INS P COMBUSTIBLE IL DOIT ETRE PLACE S
49. ISES L appareil doit etre install sur un protecteur thermique incombustible se prolongeant sur le devant les c t s et l arri re de l appareil selon les exigences minimales ci dessous NOTE Une protection de plancher est requise pour prot ger des tincelles et de la cendre mais non pour limiter la temp rature du plancher de la chaleur rayonnante de l appareil Cet appareil a t concu et test de sorte que le plancher ne surchauffera pas m me sans protection ame lt AVANT 1 C T S J ARRI RE K VENT L CANADA 18 457 2mm 8 203 2 8 203 2 i H 16 406 4mm 8 203 2mm 8 203 2mm 2 50 8mm 99 1B AIR EXT RIEUR SI LA PIECE EST PRIV E D AIR PARCE QUE LA PRISE D AIR EXT RIEUR EST OBSTRU E PAR DE LA GLACE DES FEUILLES ETC PARCE QUE LA PORTE DE L APPAREIL EST DEMEUR E OUVERTE OU QU UN VENTILATEUR PUISSANT EST ETC DES VAPEURS ET DES FUMEES DANGEREUSES POURRAIENT ETRE ASPIREES DANS LA PIECE Les conditions suivantes indiquent qu un ensemble de prise d air ext rieur pourrait tre n cessaire Lors de la combustion le bois br le mal de la fum e s chappe des refoulements se produisent et le tirage est irr gulier e En hiver les fen tres pr sentent une condensation excessive e 65 conditions mentionn es ci dessus semblent s am liorer en ouvrant une fen tre Un syst me de ventilation est install
50. ITCH OF HANDLE IN CLOSED POSITION W415 1226 B 05 26 14 19 ee 5 2 HANDLE AND DOOR SERVICE AND INSTALLATION BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE DO NOT STRIKE OR SLAM DOOR NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT A Remove the two screws securing the latch block to the door B Pull the handle towards the inside of the door and remove the latch block components then remove the latch block and handle Replace any damaged or worn components C To reinstall the door handle take the latch block and door handle align the top and bottom screw holes to the door as illustrated D Loosely tighten the top screw and install the two pins as illustrated E Installing the spring slip it into the bottom of the latch block and then install the screw Apply a small amount of high temperature grease to the spring prior to installation HINT Compress the spring using a flat head screw driver this allows for easy installation of the bottom screw as shown below F To ensure a proper installation the handle support should have the ability to remain in an upwards position Additionally the handle support should engage smoothly with the firebox l cb A lt A l r1 LATCH BLOCK HANDLE 5 lL SPRING gt PINS
51. L OR PARTITION OR ANY COMBUSTIBLE CONSTRUCTION DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION V 63 8A Your appliance may be connected to a factory built or masonry chimney If you are using a factory built chimney it must comply with ULCS629 Canada UL103 HT USA standards It must therefore be a 6 152 4mm Type 2100 F 1149 C chimney Use only specified components with no substitutions It is extremely important that it be installed according to the manufacturer s specifications The manufacturer s installation instructions and specified clearances should always be followed in accordance with local and national codes In Canada the CSA B365 and the CSA C22 1 installation codes are to be followed In the USA the ANSI NFPA 70 and ANSI NFPA 211 installation codes are to be followed Chimney and chimney connector must be in good condition and kept clean W415 1226 B 05 26 14 13 4 1 1 CONNECTION Your chimney connector chimney must have the same diameter as the exhaust flue outlet The appliance pipe must be made of aluminized or cold roll steel with a minimum 24 gauge 0 6mm thickness It is strictly forbidden to use galvanized steel 6 152 4mm diameter single wall chimney connector used to connect the appliance to the chimney must be installed with the crimped end toward the appliance This will ensure that the moisture which condenses from the bu
52. ND COMBUSTIBLE TT ESPACEUR MURAL OU MUR EXTERIEUR COUPE FEU S ff CONDUIT DE RACCORDEMENT MUR BASE DE COMBUSTIBLE PROTECTION ETT TFT gt W415 1226 05 27 14 of 4 1 5 INSTALLATION TYPIQUE DANS UNE CHEMIN E DE MACONNERIE EXISTANTE Vous pouvez aussi installer votre appareil en pe utilisant votre chemin e de magonnerie existante rr Pour ce faire suivez les directives suivantes LIT Nous vous conseillons d installer un coupe feu RL I I pr fabriqu ou d en construire un Si vous utilisez une chemin e en ma onnerie vous devez vous assurer qu elle r ponde aux CHEVRON E LIT AVANT TOIT normes de construction de votre r gion LJ TO Elle doit tre construite de briques d argile D GAGEMENT AVEC UN COUPE FEU r fractaire de tuiles de m tal ou d argile TH ciment s ensemble avec du ciment FS LH r fractaire Les conduits de chemin e SOLIVE DE PLAFOND ET D GAGEMENT ronds sont les plus efficaces maximum L I T du conduit carr est 8 203 2mm x 8 MUR COMBUSTIBLE 203 2mm ou 6 152 4 pour une A conduit circulaire a TL L TI 1 CONDUIT DE m ps RACCORDEMENT oy L kose 11 TT L TI l L I TI TT BASE DE LIT PROTECTION L 11 adidas l 62 1A W415 1226 B 05 27 14 FR 58 5 0 FINITIONS 5 1
53. OIT UN PLACARD OU AUTRE ENDROIT DISSIMUL OU TRAVERSER UN PLANCHER UN PLAFOND UN MUR OU UNE CLOISON OU TOUTE AUTRE CONSTRUCTION COMBUSTIBLE N UTILISEZ AUCUN MAT RIAU DE FORTUNE DURANT L INSTALLATION 63 8A Votre appareil peut tre raccord une chemin e de magonnerie ou pr fabriqu e Si vous utilisez une chemin e pr fabriqu e elle doit se conformer aux normes ULCS629 au Canada ou UL103 U tre de type HT 2100 F 1149 C et avoir un diam tre de 6 152 4mm N utilisez que les composants sp ci s sans aucun substitut est extr mement important que la chemin e soit install e selon les speci cations du fabricant Les directives d installations du fabricant et les d gagements sp ci s doivent toujours tre respect s en fonction des normes locales et nationales Conformez vous aux codes d installation CSA B365 et CSA C22 1 au Canada et aux codes ANSI NFPA 70 et ANSI NFPA 211 aux tats Unis La chemin e et le conduit de raccordement doivent tre gard s en bonne condition et propres W415 1226 B 05 27 14 53 4 1 1 INSTALLATION DE LA CHEMIN E Votre conduit de raccordement et votre chemin e doivent avoir le m me diam tre que le tuyau d chappement de l appareil Le tuyau de l appareil doit tre en acier alumini ou en acier lamin froid d une paisseur minimale de calibre 24 0 6mm est strictement interdit d utiliser de l acier galvanis Un conduit de raccordement paroi
54. ON DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS ATTE NT QUAND L APPAREIL LA SURFACE DEVIENT FAL TEIN TITAN CHAUDE NE PAS TOUCHER TENIR LES ENFANTS LES V TEMENTS ET LES MEUBLES L CART LE CONTACT PEUT CAUSER DES BR LURES LA PEAU U S Environmental Protection Agency Certified to comply with July 1990 particulate emissions standards Certifi conforme la norme d manation de particles de juillet 1990 40 CFR Part 60 Subpart AAA DATE CODE DE DATE WOLF STEEL LTD 400 24 NAPOLEON ROAD BARRIE ON L4M 0G8 CANADA EPA1 i W385 1901 W415 1226 B 05 27 14 49 3 0 PLANIFICATION DE L INSTALLATION 3 1 3 2 INSTALLATION DE L APPAREIL Faites installer votre po le par un d taillant autoris Si vous l installez vous m me faites v rifier vos plans d installation et ou l installation par votre d taillant Elaborez un plan d taill de l installation en y incluant les dimensions puis v rifiez les dimensions avec les exigences nonc es dans ce manuel Pour les enceintes d encastr lorsque vous d terminez l emplacement du po le localisez les montants du mur pour des vacuations horizontales Vous devrez possiblement ajuster la position du po le afin que l vent ne passe pas au m me niveau qu une pi ce de charpente Le po le doit tre positionn de facon ce qu aucun article combustible soit plac ou puisse pivoter p
55. OT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES OR IN THE SPACE REQUIRED FOR RE FUELING AND ASH REMOVAL When loading the appliance ensure that the upper fibre baffles are not forced out of position For maximum efficiency when the appliance is thoroughly hot load it fully to the top of the door opening and burn at a medium low setting The whiteness of the bricks and the cleanliness of the glass are good indicators of your operating efficiency Not enough heat is produced when only a few pieces of wood are burned or the wood may not burn completely Fuel for the appliance must not be stored closer than the required clearances to combustibles heat sensitive material NEVER STORE WOOD IN THE ASH PAN COMPARTMENT if applicable NOTE When loading the appliance ensure to keep fuel back from the glass If coals are to accumulate on the front lip there is a chance they will fall out when the door is opened Burn only dry clean unpainted wood that has been seasoned It produces more G FLOW heat and less soot or creosote Freshly cut wood contains about 5096 moisture EP while after proper seasoning only about 2096 of the water remains As wood is burned this water boils off consuming energy that should be used in heating The wetter the wood the less heat is given off and the more creosote is produced Dry firewood has cracks in the end of the grain appliance but hardwood is denser will weigh more AIR FLOW per
56. POUR PREVENIR LES BLESSURES NE LAISSEZ PAS L APPAREIL SANS SUPERVISION LORSQUE LES PORTES SONT DEVERROUILLEES DU BOIS INSTABLE POURRAIT TOMBER HORS DE LA CHAMBRE DE COMBUSTION ET CREER UN RISQUE D INCENDIE NE LAISSEZ JAMAIS LES ENFANTS SANS SURVEILLANCE LORSQU UN FEU BRULE DANS L APPAREIL N UTILISEZ JAMAIS D ESSENCE DE COMBUSTIBLE LANTERNE DE KEROSENE D ESSENCE BRIQUET OU D AUTRES LIQUIDES POUR ALLUMER OU RAVIVER UN FEU DANS CET APPAREIL GARDEZ TOUS CES LIQUIDES LOIGN S DE L APPAREIL LORSQUE CELUI CI FONCTIONNE LES OBJETS PLAC S DEVANT L APPAREIL DOIVENT TRE GARD S UNE DISTANCE D AU MOINS 48 1219 2mm DE LA FACE VITREE TOUTE MODIFICATION APPORT E L APPAREIL QUI N A PAS T PR ALABLEMENT APPROUV E PAR CRIT PAR LE LABORATOIRE D ESSAI EST CONSID R COMME UNE VIOLATION DES NORMES CSA B365 CANADA ET ANSI NFPA 211 U OUVREZ LE CONTR LE DE COMBUSTION ET LE REGISTRE S IL Y A LIEU AVANT D OUVRIR LA PORTE DE L APPAREIL L APPAREIL EST CHAUD LORSQU IL FONCTIONNE TENIR LES ENFANTS LES V TEMENTS ET LES MEUBLES L CART LE CONTACT PEUT CAUSER DES BR LURES PORTEZ DES GANTS LORSQUE VOUS OP REZ VOTRE APPAREIL FAIRE FONCTIONNER CET APPAREIL AVEC LES PORTES OUVERTES OU ENTROUVERTES CR E UN RISQUE D INCENDIE DE CHEMINEE OU DU DOMICILE Votre appareil Napoleon certifi aux normes EPA est un appareil de haute technologie concu selon les principes technologiques les plus avanc s Cet appareil es
57. RATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING START UP AND RE FUELING ALWAYS WEAR GLOVES TO PREVENT INJURY DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME NEVER LEAVE CHILDREN UNATTENDED WHEN THERE IS FIRE BURNING IN THE APPLIANCE NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS APPLIANGE KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE APPLIANCE WHILE IT IS IN USE OBJECTS PLACED IN FRONT OF THE APPLIANCE SHOULD BE KEPT A MINIMUM OF 48 1219 2mm FROM THE FRONT FACE ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED BREACHING CSA B365 CANADA AND ANSI NFPA 211 USA OPEN AIR CONTROL AND DAMPER WHEN FITTED BEFORE OPENING FIRING DOOR HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS WEAR GLOVES TO OPERATE YOUR APPLIANCE BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE Your appliance is Hi Tech designed with the most advanced technology This appliance is extremely airtight It has an exclusive direct outside air supply optional kit a feature designed to prevent spillage and to help keep your house free of carbon monoxide in case of a down dra
58. RE LA CORROSION NOUS CONSEILLONS QUE LE DESSUS DE L ENCEINTE SOIT PEINT AVEC UNE PEINTURE ANTIROUILLE NE REMPLISSEZ AUCUN ESPACE CHARPENT AUTOUR DU CONDUIT AVEC DE L ISOLANT OU TOUT AUTRE MATERIAU L ISOLANT POSE DANS CET ESPACE POURRAIT CAUSER LES MATERIAUX COMBUSTIBLES AVOISINANTS A SURCHAUFFER CONSERVEZ UN D GAGEMENT MINIMAL DE 2 25 4mm TOUTES LES PIECES DU SYSTEME DE CONDUITS EN TOUT TEMPS OMETTRE DE CONSERVER CE D GAGEMENT DE 2 25 4mm CAUSERA UN INCENDIE NE REMPLISSEZ CET ESPACE AVEC AUCUN TYPE DE MAT RIAU DES INSTRUCTIONS D TAILL ES SUR L INSTALLATION DU DESSUS DE L ENCEINTE DU COLLET DE SOLIN ET DU CHAPEAU SONT INCLUSES AVEC CES PIECES LE DEGAGEMENT MINIMUM A COMBUSTIBLE VARIERA SELON LEUR CONCEPTION NE COUPEZ PAS DE CHEVRONS NI DE SOLIVES DE PLAFOND SANS AVOIR CONSULT AU PREALABLE LES AUTORITES EN BATIMENT POUR VOUS ASSURER QUE L INTEGRITE DE LA STRUCTURE N EST PAS COMPROMISE DES ESPACEURS COUPE FEU DOIVENT TRE UTILIS S LORSQUE LE SYSTEME DE CONDUITS TRAVERSE UN PLAFOND PLANCHER LA LONGUEUR TOTALE DE LA COURSE HORIZONTALE NE DEVRAIT PAS EXC DER 40 DE LA HAUTEUR DE LA CHEMIN E PARTIR DU DESSUS DU PO LE TOUTES LES COURSES HORIZONTALES DOIVENT AVOIR UNE PENTE MINIMALE VERS LE HAUT DE 1 4 6 4mm PAR PIED m tre ET TOUS LES RACCORDEMENTS DOIVENT TRE SCELL S ET FIX S PAR TROIS VIS AUTOPERCEUSES ESPAC ES GALEMENT UN TUYAU DE RACCORDEMENT NON ISOL NE DOIT PAS TRAVERSER UN GRENIER UN ENTRET
59. S QUAND L APPAREIL FONCTIONNE LA SURFACE DEVIENT CHAUDE NE PAS TOUCHER TENIR LES ENFANTS LES V TEMENTS ET LES MEUBLES L CART LE CONTACT PEUT CAUSER DES BR LURES LA PEAU CLEARANCES TO COMBUSTIBLE CONSTRUCTION DEGAGEMENTS AUX MATERIAUX COMBUSTIBLES MEASURED TO UNIT A PARTIR DE L APPAREIL A SIDE FACING C T 1 IN PO 25mm B TOP FACING DESSUS 28 IN PO 710mm C MANTEL TABLETTE 28 IN PO 710mm D SIDE WALL MUR LAT RAL 17 IN PO 430mm CLEARANCE TO EDGE OF FLASHING D GAGEMENT AU BORD DE LA FAGADE FLOOR PLANCHER U S Environmental Protection Agency Certified to comply with July 1990 particulate emissions standards Certifi conforme la norme d manation de particles de juillet 1990 40 CFR Part 60 Subpart AAA WOLF STEEL LTD 24 NAPOLEON ROAD BARRIE ON L4M 0G8 CANADA DATE CODE DE DATE 52 3 0 PRE INSTALLATION PREPARATION 3 1 APPLIANCE PLACEMENT Have an authorized dealer install the appliance If you install the yourself have your dealer review your installation plans and or installation Draw out a detailed plan of the installation including dimensions and verify the dimensions with the require ments listed in this manual You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing member Appliance must be positioned so that no combustibles are within or can swing within e g drapes
60. SERVICE HISTORY 13 0 NOTES NOTE Changes other than editorial are denoted by a vertical line in the margin 415 1226 05 26 14 O 5 om 4 1 0 INSTALLATION OVERVIEW Rating plate see RATING PLATE INFORMATION section Door see DOOR REMOVAL AND INSTALLATION section Blower see OPTIONAL BLOWER KIT INSTALLATION section Draft see AIR CONTROL section Handle see DOOR AND HANDLE INSTALLATION Ash drawer see ASH AND SERVICE section DRAWER ADJUSTMENT section Brick and baffles see BRICK AND BAFFLE INSTALLATION section W415 1226 B 05 26 14 4 2 0 INTRODUCTION e THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED e CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS BE DANGEROUS AND IS PROHIBITED e not operate appliance before reading and understanding operating instructions Failure to operate appliance according to operating instructions could cause fire or injury e Before installing this appliance contact the local building or fire authority and follow their guidelines e This appliance must be installed by a qualified installer e Risk of burns The appliance should be turned off and cooled before servicing Donot operate without fully assembling all components e not let the appliance become hot enough for any part to glow red e Do not install
61. STRUCTIONS G N RALES 46 2 4 INFORMATION G N RALE 47 2 5 INFORMATION SUR LA PLAQUE D HOMOLOGATION 48 3 0 PLANIFICATION DE L INSTALLATION 49 3 1 INSTALLATION DE L APPAREIL 49 3 2 D GAGEMENTS AUX MAT RIAUX COMBUSTIBLES 49 3 3 PROTECTION DU PLANCHER 50 3 4 AIR EXT RIEUR 50 3 4 1 PRISE D AIR EXT RIEUR MAISON MOBILE 50 4 0 INSTALLATION 51 4 1 CHEMIN E 52 4 1 1 INSTALLATION DE LA CHEMIN E 53 4 1 2 AJOUT DE SECTIONS 54 4 1 3 TYPIQUE TRAVERS LE PLAFOND 55 4 1 4 INSTALLATION TYPIQUE TRAVERS UN MUR 56 4 1 5 INSTALLATION TYPIQUE DANS UNE CHEMIN E DE MA ONNERIE EXISTANTE 57 5 0 FINITIONS 58 5 1 ENL VEMENT ET INSTALLATION DE LA PORTE 58 5 2 INSTALLATION DE LA PORTE ET DE LA POIGN E DE PORTE 59 5 3 INSTALLATION DES BRIQUES ET DES D FLECTEURS EN FIBRE 60 5 4 AJUSTEMENT DU TIROIR CENDRES 62 6 0 INSTALLATIONS DES ENSEMBLES OPTIONNELLE 63 6 1 INSTALLATION DE L ENSEMBLE DU SOUFFLERIE 63 6 1 1 INSTALLATION DE LA SOUFFLERIE 63 6 2 GARNITURE DU PORTE 64 7 0 FONCTIONNEMENT 65 7 1 CONTROLE D AIR 66 7 2 EXTINCTEURS ET DETECTEURS DE FUMEE 66 7 3 ALLUMER UN FEU 67 7 3 1 FEU ECLAIR 67 7 3 2 FEU CONTINU 67 7 4 ENFUMAGE 67 8 0 ENTRETIEN 68 8 1 ENLEVEMENT DES CENDRES 68 8 2 FORMATION ET ENLEVEMENT DE LA CR OSOTE 69 8 3 FEU DE OU FEU HORS CONTROLE 69 8 4 NETTOYAGE DE LA CHEMIN E 70 8 5 REMPLACEMENT DE LA VITRE 70 8 6 TUYAUX D AIR SECONDAIRE 71 8 7 SOINS DE LA VITRE 72 8 8 SOINS DES
62. T BE PLACED ON A NON COMBUSTIBLE FLOOR PROTECTOR EXTENDING 18 455mm IN FRONT AND 8 205mm TO THE SIDES AND BACK CHIMNEY TYPE MINIMUM 6 152mm DIAMETER APPROVED RESIDENTIAL TYPE FOR MOBILE HOME USE A CHIMNEY LISTED TO ULC S629 IN CANADA OR UL 103HT IN THE USA CHIMNEY CONNECTOR 6 152mm DIAMETER MINIMUM 24 GAUGE STEEL MINIMUM CLEARANCE FROM HORIZONTAL CONNECTOR AND CEILING 18 455mm DO NOT OBSTRUCT SPACE UNDER HEATER SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY THROUGH A WALL OR CEILING SEE INSTRUC TIONS AND BUILDING CODES DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FUEL FOR USE WITH WOOD ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH WARNING RISK OF SMOKE SPILLAGE OPERATE ONLY WITH DOOR FULLY CLOSED REPLACE GLASS ONLY WITH CERAMIC GLASS DO NOT OVERFIRE IF HEATER OR CHIMNEY CONNECTORS GLOW YO ARE OVERFIRING INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER DISCONNECT POWER BEFORE SERVIGINGIUI INSERT INST I BURNING FIRE REMOVE BRICKS MORTAR FROM SOLID FUEL BURNING FIREPLAGE INSTALL WITH A POSITIVE FLUE CONNECTOR AND FACEPLATE ATTENTION LISTED SOLID FUEL BURNING SPACE HEATER POELE A COMBUSTIBLE SOLIDE HOMOLOGUE TESTED TESTE SELON UL1482 ULC 5627 MODEL MODELE EPA 1400 1400L 1400C S4 1400 1450 POUR INSTALLATION ET UTILISATION CONFORMEMENT AUX CONTACT LOCAL BUILDIN
63. TANTES APPORT ES AU PRODUIT NAPOL ONG EST UNE MARQUE DE COMMERCE D POS E DE WOLF STEEL LT E 2 2B W415 1226 B 05 27 14 FR 78 12 0 HISTORIQUE D ENTRETIEN Travail effectu Probl mes particuliers Historique d entretien Wolf Steel Nom du technicien 9 CO 4 o o lt E o H D D O Le ol O D taillant W415 1226 B 05 27 14 79 13 0 NOTES W415 1226 05 27 14 NAPOLEON 7200 Route Transcanadienne Montr al Qu bec H4T 1A3 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 Foyers Chauffage et Climatisation Grils composez 514 737 6294 napoleonproducts com Foyers encastr s Grils au charbon de bois 9 Foyers au gaz Cascades d eau Po les a bois e Produits HVAC e Foyers lectriques e Foyers ext rieurs e Grils gaz de qualit
64. TE HAZARDOUS INSTALLATION READ THROUGH THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM CAREFULLY THROUGHOUT YOUR PROJECT J Before beginning your installation consult with your local building code agency or fire officials and insurance representative to ensure compliance Non toxic smoke will be emitted during the paint curing process to help dissipate the smoke open a window near the appliance Remove any dust or debris off the top of the appliance before firing the appliance as the paint will become soft as the appliance heats up and will harden as the appliance cures To cure the paint on your appliance burn your appliance moderately hot during the first few fires To keep the gasket from sticking to the appliance as the paint is curing periodically open the door every 5 10 minutes For the first two weeks use generous amounts of fuel and burn the appliance with the damper wide open for an hour as the appliance goes through a process of eliminating moisture in the firebricks The initial heat output will be reduced while the moisture is being drawn from the appliance and it will be necessary to build several hot fires to remove this moisture DURING THIS PROCESS DO NOT OVER FIRE THE APPLIANCE REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED W415 1226 B 05 26 14 2 4 GENERAL INFORMATION DO NOT OPERATE THIS APPLIANCE WITHOUT THE P
65. TIONNELLE 6 1 INSTALLATION DE L ENSEMBLE DU SOUFFLERIE RISQUE D INCENDIE ET DE CHOC LECTRIQUE COUPEZ L ALIMENTATION EN GAZ ET L ALIMENTATION LECTRIQUE AVANT DE PROC DER L ENTRETIEN DE L APPAREIL N UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES 5 DE RECHANGE APPROUV S PAR WOLF STEEL POUR CET APPAREIL L UTILISATION D ACCESSOIRES NON LISTES SOUFFLERIE PORTES PERSI ENNES MOULURES COMPOSANTS DE GAZ COMPOSANTS D EVACUATION ETC POURRAIT ETRE NON S CURITAIRE ET ANNULERA LA GARANTIE ET LA CERTIFICATION AFIN DE PR VENIR LES CHOCS LECTRIQUES ET LES DOMMAGES CAUS S PAR LE FEU ASSUREZ VOUS QUE LE CORDON D ALIMENTATION DU VENTILATEUR N ENTRE PAS EN CONTACT AVEC QUELCONQUE SURFACE DE L APPAREIL NE FAITES PAS PASSER LE CORDON D ALIMENTATION SOUS L APPAREIL LE HARNAIS DE FILS FOURNI DANS L ENSEMBLE DE SOUFFLERIE EST UN HARNAIS UNIVERSEL LORS DE SON INSTALLATION ASSUREZ VOUS QUE TOUT EXCES DE FIL EST CONFINE L EMPECHANT AINSI D ENTRER EN CONTACT AVEC DES OBJETS CHAUDS OU MOBILES 515 est possible d installer une soufflerie optionnelle EP65 avec un interrupteur vitesse variable servant faire partir et arr ter la soufflerie ainsi qu a contr ler sa vitesse et une d tecteur thermostatique pour activ par la chaleur La poussi re de gypse p n trera dans le roulement billes de la soufflerie causant des dommages irr parables Vous devez viter que cette poussi re n entre en contact avec la so
66. UR UNE BASEIDE PROT BLE CERTIFEE QUI DOIT DEPASSER DU P 00mm ET SE PROLONGER DE 18 D THE STOMEISIDES AND BACK AND 18 IBLE MATERIAL WITH SINGLE WALL USING DOUBLE WALL CONNECTOR WTILISATION D UN CONDUIT DE MAISON MOBILE HOME 1400 S4 JIN PO 254 mm 16 406 mm 10IN PO 254 mm 16IN PO 406 mm 6IN PO 152 mm 6IN PO 152 6IN PO 152 mm 152 mm 4IN PO 102 mm 4IN PO 102 mm 4IN PO 102 mm 4IN PO 102mm TESTED TO TEST SELON ULC 8628 UL 1482 EPI 1402 SOUFFLERIE OPTIONNELLE EP 62 115V 60HZ 0 82A TENEZ LE GORDON LECTRIQUE LOIN DE APPAREIL IT DANGER RISQUE DE SECOUSSE LECTRIQUE D BRANCHEZ AVANT CEILING PLAFOND CLEARANCES TO COMBUSTIBLE CONSTRUCTION DEGAGEMENTS AUX MATERIAUX COMBUSTIBLES MEASURED TO UNIT A PARTIR DE L APPAREIL DE PROC DER L ENTRETIEN A SIDE FACING C T 1 IN PO 25mm ENCASTR INSTALLEZ ET UTILISEZ B TOP FACING DESSUS 28 IN PO 710mm SEULEMENT DANS UN FOYER C MANTEL TABLETTE 28 IN PO 710mm 4 m FUEL COMBUSTIBLE SOLIDE NE RETIREZ D SIDE WALL MUR LAT RAL 17 IN PO 430mm BU PAS DE MORTIER BRIQUES DU FLOOR PLANCHER x INSTALL OSITIVE FOYER COMBUSTIBLE SOLIDE CLEARANCE TO EDGE OF FLASHING D GAGEMENT AU UE AND INSTALLEZ AVEC UNE GAINE PORD DE TA TACADE FAC E CONFORME ET UNE PLAQUE DE RECOUVREMENT CAUT N e HOT WHILE IN OPERATI
67. WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL THE OUTSIDE AIR INLET MUST REMAIN CLEAR OF LEAVES DEBRIS ICE AND OR SNOW IT MUST BE UNRESTRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABILITY TO MAINTAIN FIRE SMOKE CAN ALSO SET OFF SMOKE ALARMS NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANGE TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION THE APPLIANCE MUST NOT BE INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION LOCALIZED OVERHEATING COULD OCCUR AND FIRE COULD RESULT DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION DO NOT BLOCK OR RESTRICT AIR GRILLE OR LOUVRE OPENINGS DO NOT ADD HOOD KEEP HAND TOOLS IN GOOD CONDITION SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES ARE SECURE ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES 68 3A W415 1226 05 26 14 12 4 1 CHIMNEY NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO COMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE TO AVOID DANGER OF FIRE ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED INCLUDING THE PROVISIONS OF AIR SP
68. carefully close the door Closing the door too quickly after refuelling will reduce the firebox temperature and result in an unsatisfactory burn Remember it is more efficient to burn medium sized wood briskly and refuel frequently than to load the appliance with large logs that result in a smouldering inefficient fire and dirty glass As soon as the door is closed you will observe a change in the flame pattern The flames will get smaller and lazier because less oxygen is getting into the combustion chamber The flames however are more efficient The flames will remain lazy but become larger again as soon as the firebricks have been heated thoroughly and the chimney becomes heated and provides a good draft At this point the roaring fire that you see when the door is opened is wastefully drawing heated room air up the chimney certainly not desirable Always operate with the door fully closed once the medium sized logs have caught fire W415 1226 B 05 26 14 26 7 1 7 2 You can now add larger pieces of wood and operate the appliance normally Once the appliance is entirely hot it will burn very efficiently with little smoke from the chimney There will be a bed of orange coals in the firebox and secondary flames flickering just below the top firebrick You can safely fill the firebox with wood to the top of the door and will get best burns if you keep the chimney connector temperatures between 250 120 C and 450 F 270 W
69. ces instructions A Retirez les vis de fixation des crans lat raux faites les glisser vers l avant et retirez les de 0077 B l appareil B Retirez les vis de fixation de l cran arri re puis retirez l cran de l appareil Enlevez les briques arri re puis retirez le d flecteur Retirez les deux ecrous et boulons de fixation du tuyau d air secondaire pour 51 et S4 et 4 crous et boulons de fixation de la S9 r f rez vous l illustration ci dessous E Retirez le tuyau d air secondaire LES DEUX VIS EXT RIEUR SONT SUR LE S9 MODELE Pour installer tuvaux d air secondaire suivre ces instructions VUE DU C T A Rep rez la fente l avant de la chambre de combustion 7 TUYAUX D AIR comme illustr SECONDAIRE Y ECROU ET BOULON X2 B Ins rez la patte du tuyau d air secondaire dans la fente mentionn e ci dessus et faites pivoter le tuyau d air FENTE secondaire en position C Un nouveau joint DOIT tre install entre le tuyau CRAN ET JOINT d air secondaire et la chambre de combustion UT _ AUTONETTOYANT D Ins rez un des boulons pour maintenir le tuyau d air secondaire en place E En travaillant l int rieur de la chambre de combustion prenez le deuxi me boulon et installez le en position en serrant l g rement la rondelle et l crou F Retirez le premier boulon et r in
70. concerne ce produit ses composants ou accessoires est exclue NAPOL ON n endosse ni n autorise aucun tiers assumer en son nom toute autre responsabilit concernant la vente de ce produit NAPOL ONG ne sera pas responsable d une surchauffe des refoulements des d versements caus s par des conditions environnementales telles que des toits des b timents la proximit d arbres de collines de montagnes une ventilation ou des vents inad quats des configurations d vacuation excessives un apport d air insuffisant ou des pressions n gatives qui peuvent ou non tre caus s par des syst mes m caniques tels que les ventilateurs d vacuation les fournaises les s che linge etc Tout dommage caus l appareil la chambre de combustion l changeur de chaleur aux garnitures plaqu es ou autres composants par l eau les dommages caus s par les intemp ries de longues p riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de NAPOL ONG NAPOL ON se r serve le droit de demander son repr sentant d inspecter tout produit ou pi ce avant d honorer toute r clamation Toutes les pi ces remplac es en vertu de la politique de Garantie vie limit e du Pr sident ne peuvent faire l objet que d une seule r clamation Durant les dix premi res ann es NAPOLEON remplacera ou r parera les pi ces d fectueuses qui sont couvertes par la garantie vie li
71. cord and burn a little slower and longer AIR FLOW Firewood should be split stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of likelihood that the wood will roll onto the glass Manufactured firelogs made by compressing 100 natural wood fibre can be safely used as fuel Do not use manufactured firelogs if they contain additives such as paraffin wax binders etc Never burn more than two manufactured firelogs at a time DO S DONT S Build a hot fire Take ash out immediately Let it accumulate to a Use only dry wood depth of at least one inch A good ash layer provides Several pieces of medium sized wood are better for a longer lasting and better burning fire than a few big pieces Burn wet wood Clean chimney regularly Close the door too soon or damper down too quickly Refuel frequently using medium sized wood Burn one large log rather than two or three smaller Fine Tune the air settings for optimum more reasonably sized logs performance Burn at continually low setting if glass door is constantly blackened This means the firebox temperature is too low 87 1B W415 1226 B 05 26 14 34 9 0 REPLACEMENTS Contact your dealer or the factory for questions concerni
72. couvercle ou la chute cendres de fermer TIROIR DE ENDRES E E COUVERCLE DE CENDRIER Ceci engendre des risques qui pourraient causer un feu de chemin e ou un incendie ainsi que des dommages internes l appareil ou la d coloration de la porte plaqu e or les finis plaqu s ne sont pas couverts par la garantie Pour vous assurer que la chute cendres est compl tement ferm e assurez vous que la porte se ferme avec un bruit sec d logeant ainsi ce qui pourrait tre coinc dans l ouverture NOTE ASSUREZ VOUS QUE LE CENDRIER EST COMPLETEMENT REFOIDIT AVANT D ENLEVER LE TIROIR DE CENDRE W415 1226 B 05 27 14 8 2 8 3 69 Tirer le tiroir de cendre avant pour ouvrir ceci gagne l acc s au cendrier Enlever le cendrier par levant la cote gauche ou au cote droite du tiroir de cendre Temporairement placer le cendrier sur une surface incombustible et fermer le couvercle de cendrier Enlever le cendrier et liminer les cendres en toute s curit Avant de r installer le cendrier assurez vous que le couvercle de cendrier est OUVERT Placer le cendrier dans le tiroir de cendre et puis fermer le tiroir de cendre NE FAITES JAMAIS FONCTIONNER VOTRE APPAREIL QUAND LA CHUTE CENDRES EST ENTROUVERT OU OUVERTE FORMATION ET ENLEVEMENT DE LA CREOSOTE Lorsque le bois brule lentement il produit du goudron et autres vapeurs organiques qui se combinant la vapeur d eau vacu e forme la
73. cr osote Ces vapeurs se condensent dans le conduit relativement froid de la chemin e d un appareil br lant lentement et lorsqu elle prend feu la cr osote produit un feu extr mement chaud Par cons quent le tuyau de raccordement gaine de chemin e et la chemin e devraient tre inspect s mensuellement pendant la saison de chauffage afin de d terminer si une accumulation s est produite L accumulation de cr osote doit tre enlev e pour r duire le risque d un feu de chemin e FEU DE OU FEU HORS CONTROLE UN FEU DE PEUT ENDOMMAGER VOTRE DE FACON PERMANENTE POUR REPARER CES DOMMAGES VOUS DEVREZ REMPLACER LES COMPOSANTS ENDOMMAGES LES FEUX DE CHEMINEE NE SONT 5 COUVERTS LA GARANTIE VIE LIMITEE Des feux hors contr le peuvent tre caus s par les trois facteurs suivants L utilisation d un combustible inappropri ou de morceaux de bois trop petits qui normalement auraient t utilis s comme bois d allumage Une porte laiss e entrouverte trop longtemps creant des temperatures extremes lorsque l air est entrain pr cipitamment par la porte ouverte Faire fonctionner l appareil avec le couvercle de la chute cendres mal install EUROS Ne brulez pas de bois trait ou transform de charbon de charbon de bois de papier de couleur ou de carton Faites attention de ne pas surchauffer l appareil en laissant la porte ouverte trop
74. des certifi es pour cet appareil peuvent tre utilis es avec cet appareil e Gardez les mat riaux d emballage hors de la port e des enfants et mettez ces mat riaux au rebut de fa on s curitaire Comme tous les emballages de plastique ces mat riaux ne sont pas des jouets et doivent demeurer hors de la port e des enfants et des b b s e Sicet appareil n est pas install de fa on ad quate un incendie pourrait s ensuivre N exposez pas l appareil aux l ments ex la pluie etc et gardez le au sec en tout temps De l isolant humide produira une odeur lorsque l appareil est utilis Lachemin e doit tre en bon tat et ne pas tre fissur e Nettoyez la chemin e au moins deux fois par ann e et lorsque n cessaire e Nallumez pas votre feu l aide de produits chimiques ou de liquides tels que de l essence de l huile moteur etc e Votre appareil n cessite un entretien et un nettoyage p riodiques N gliger cet entretien peut causer des refoulements de fum e dans la maison e Vous obtenez une meilleure efficacit et des missions plus basses avec du bois dur s ch l air qu avec du bois r sineux vert ou des bois durs fraichement coup s Br ler du bois vert ou humide peut causer des accumulations excessives de cr osote Lorsqu elle est allum e cette derni re peut causer un feu de chemin e et un incendie grave pourrait s ensuivre e Cet appareil a t concu pour br ler du bois naturel uniquement
75. doors 48 1219 2mm of the front of the appliance 67 1B 3 2 CLEARANCE TO COMBUSTIBLES DO NOT INSTALL INTO ANY AREA HAVING HEIGHT LESS THAN 7 FEET 2 1m CEILING OF ENCLOSURE TO APPLIANCE BOTTOM EXCLUDING HEARTH HEIGHT BACK WALL BACK WALL gt PARALLEL amp CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR s s M s 16 SIDEWALL A 16 22 16 16 22 559mm SIDE WALL SIDE WALL u 406mm 533mm 533mm 533mm 483mm 483mm 483mm 254mm 305mm 305mm 152mm 152mm 8 406 559mm 406mm 406mm 305mm CORNER E 6 6 8 152mm 152mm 203mm b1mm 102mm 203mm CEILING 84 84 84 8 84 2134 2134 2134mm 2134mm 2134mm 2134mm Clearances can be reduced with shielding acceptable to local authorities Reduced installation must comply with NFPA 211 or CAN CSA B365 19 19 6 6 330mm 419mm 419mm 229mm 229mm 419mm 2 4 84 4 415 1226 05 26 14 10 3 3 FLOOR PROTECTION EMBER PROTECTOR This appliance must be installed on a non combustible protector that extends to the front sides and back of the appliance as per the minimum requirements below NOTE Ember protection is required for spark and ash shielding not for limiting floor temperatures from the radiant heat of the appliance The appliance was designed and safety
76. e combustion L air p n tre par l ouverture avant et s engage de chaque c t de la porte pour rejoindre un collecteur de pr r chauffement install au sommet de la chambre 8 8 de combustion L air descend ensuite le long de la vitre AIR SECONDAIRE CH our alimenter le feu et aussi assurer que la vitre demeure EE Ul R FRACTAIRES propre L air provenant de cette ouverture p n tre aussi directement dans la chambre de combustion au niveau Er de l tre L air secondaire p n tre par l ouverture arri re monte par l arri re le long du tube d air secondaire VITRE EN CERAMIQUE CONTR LE D AIR e ig FERM jusqu au collecteur install au sommet o l air est propuls OUVERT lat ralement pour oxyder les gaz sous la sortie de fum e AIR PRIMAIRE NS La chambre de combustion inferieure est revetue de briques AIR SECONDAIRE r fractaires haute temp rature sur deux c t s l arri re et le plancher Le plafond est rev tu de d flecteurs en fibre afin de maintenir une temp rature lev e dans la chambre de combustion Ainsi les gaz qui se m langent l air pr r chauff dans le tuyau d air secondaire s allument et br lent facilement Les c t s et l arri re de l appareil sont munis d une deuxi me paroi de fa on diriger la chaleur vers le haut et vers l avant dans la pi ce Assurez vous y ait suffisamment d air comburant Dans la maison beaucoup d appar
77. e the manufacturer will repair or replace such defect Before shipping your appliance or defective components your dealer must obtain an authorization number Any merchandise shipped without authorization will be refused and returned to sender Shipping costs are not covered under this warranty Additional service fees may apply if you are seeking warranty service from a dealer Warranty labour allowance is only for the replacement of the warranted part Travel diagnostic tests shipping and other related charges are not covered by this warranty ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON GOING PRODUCT IMPROVEMENTS NAPOLEON IS A REGISTERED TRADEMARK OF WOLF STEEL LTD _ 2 2B W415 1226 B 05 26 14 38 12 0 SERVICE HISTORY Special Concerns Service Performed gt Ki L Q 9 E o Q 6 Q et O D c O E c Q gt 6 c D 9 2 T o p 2 Service Technician Dealer 43 1 415 1226 05 26 14 39 13 0 NOTES W415 1226 05 26 14 NAPOLEON 24 Napoleon Road Barrie Ontario Canada L4M 068 214 Bayview Drive Barrie Ontario Canada LAN 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Trans Canada Highway Montreal Quebec Canada H4T 1A3 Fireplaces Heating am
78. e appliance and clean both the chimney and the appliance You may want to call a professional chimney sweep to clean them Both have to be cleaned at least once a year or as often as necessary Inspect the secondary air tubes Remove fibre baffles and clean above them once a year Replace any broken bricks Inspect and replace all the gaskets as required Disassemble clean and lubricate the door handle assembly ASH REMOVAL PROCEDURES IMPROPER DISPOSAL OF ASHES RESULT IN FIRES DO NOT DISCARD ASHES IN CARDBOARD BOXES DUMP IN BACK YARDS OR STORE IN GARAGES IF USING A VACUUM TO CLEAN UP ASHES BE SURE THE ASHES ARE ENTIRELY COOLED USING VACUUM TO CLEAN UP WARM ASHES COULD CAUSE INSIDE THE VACUUM NEVER OPERATE YOUR APPLIANCE WITH THE ASH PLUG IF APPLICABLE REMOVED FAILURE TO ACHIEVE A GOOD SEAL BETWEEN THE ASH OPENING ASH PLUG OR ASH WELL DOOR WILL RESULT IN AN OVER FIRE CONDITION THAT COULD CAUSE DAMAGE TO THE APPLIANCE Allow the ashes in your firebox to accumulate to a depth of two or three inches 51mm 76mm they tend to burn themselves up When the fire has burned down and cooled remove any excess ashes but leave an ash bed approximately 1 inch 25mm deep on the firebox bottom to help maintain a hot charcoal bed To use your ash pan pull the ash dump handle forward rotate approximately 90 counterclockwise the open PULL AND ROTATE position Rake the excess ashes into the ash pan
79. ecognized ISO 9001 2008 Quality Assurance Certificate NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The complete appliance is again thoroughly inspected by a qualified technician before packaging to ensure that you the customer receives the quality product that you expect from NAPOLEON NAPOLEON WOOD APPLIANCE PRESIDENT S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new NAPOLEON wood appliance are warranted against defects for as long as you own the appliance This covers combustion chamber heat exchanger ceramic glass thermal breakage only gold plated parts against tarnishing porcelainized enameled components aluminum extrusion trims vortex baffles ash drawer and iron castings Electrical 110V components and wearable parts such as blowers thermal switch switches wiring firebrick stainless steel baffle retainer secondary air tubes and gasketing are covered and NAPOLEONQG will provide replacement parts free of charge during the first year of the limited warranty Labour related to warranty repair is covered free of charge during the first year Repair work however requires the prior approval of an authorized company official Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer Parts such a
80. eil et doit tre plac 14 355 6mm au dessus de la buse de l appareil Installez le thermom tre selon les instructions du fabricant Vous n arrivez pas faire partir votre feu Utilisez un peu plus de bois d allumage et de papier Si la chemin e et le tuyau d vacuation sont de grandeur appropri e et s il y a suffisamment d air comburant alors le probl me est caus par une quantit insuffisante de petits morceaux de bois d allumage sec Le bois d allumage devrait avoir un diam tre quivalent celui de votre pouce Votre appareil n met pas assez de chaleur Une ou deux causes sont possibles La porte de l appareil a t ferm e pr matur ment et l appareil n a pas atteint sa temp rature optimale Ouvrez nouveau la porte et ou le contr le de combustion afin de repartir un feu vif Du bois humide pourrait etre la deuxi me cause Un bois gr sillant dou s chappe de l humidit est le sympt me typique CONTR LE D AIR Le tirage est la force qui d place l air de la chambre de combustion vers le haut dans la chemin e La force de PARE CENDRES tirage de votre chemin e d pend de sa hauteur et de son diam tre de la g ographie locale des obstructions avoisinantes et d autres facteurs incluant la quantit de chaleur mise par le feu qui peut tre mesur e l aide d un thermom tre d appareil La temp rature est contr l e par le contr le d air Le tirage peut tre ajust pour obtenir une combusti
81. eils doivent se partager l air disponible tels les hottes de cuisini re les syst mes de chauffage air puls ou les ventilateurs de salle de bain Les bruits caus s par l expansion et la contraction lors des cycles de chauffage et de refroidissement sont tout fait normaux et il faut s y attendre Apr s de longues p riodes sans utiliser l appareil telles qu la suite de vacances ou la fin de l t il se peut qu une l g re odeur se d gage pendant quelques heures Ceci est caus par des particules de poussi re br lant sur la chambre de combustion Ouvrez une fen tre afin d a rer a NATIONAL Nous sugg rons que nos po les bois j j FIREPLACE EES de maniere suffisante INSTITUTE soient install s et entretenus par des AVERTISSEMENT PROPOSITION 65 DE LA CALIFORNIE professionnels certifi s aux Etats Unis par le National Fireplace Institute amp NFI et au L utilisation de cet appareil peut produire de la fum e qui Canada par le Wood contient des substances chimiques qui selon l tat de Californie CERTIFIED nergy lechnica e Training WETT causeraient le cancer des malformations congenitales ou autres www nlicertified org dangers pour la reproduction Si vous utilisez la prise d air ext rieur de votre appareil vous ne devriez jamais manquer d air comburant Si vous choisissez de ne pas utiliser cette prise d air ext rieur et que vous avez des probl mes de tirage ou de fum e
82. eur ou le bois ne br lera pas compl tement Le combustible pour l appareil ne doit pas tre entrepos l int rieur des d gagements minimaux aux mat riaux combustibles mat riau sensible la chaleur N ENTREPOSEZ JAMAIS DE BOIS DANS LE COMPARTIMENT DU TIROIR A CENDRES s il y a lieu NOTE Lorsque vous chargez l appareil assurez vous de garder le combustible loign de la vitre Si des braises s accumulent sur le rebord avant elles pourraient tomber hors de l appareil quand vous ouvrez la porte Ne br lez que du bois propre non peint et bien sec Il produit plus de chaleur et moins de suie et de cr osote Le bois fra chement coup contient environ 50 96 d humidit tandis qu une fois s ch il n en contient que 20 96 CIRCULATION Quand le bois br le l eau bout en consommant une partie de l nergie qui aurait DAR produire de la chaleur Plus le bois est humide moins il y a v aura de chaleur et plus il y aura de creosote Le bois sec des craquelures dans les extr mit s Le bois dur brule aussi bien que le bois r sineux dans cet appareil par contre le bois dur est plus dense plus lourd brule plus lentement et plus longtemps Le bois de chauffage devra tre fendu et cord de telle fa on que l air puisse circuler ais ment au travers Il faudra couvrir la corde de bois au d but du printemps pour qu elle soit pr te tre brulee l automne suivant Coupez le bois de fa on qu il
83. fting chimney or an internal negative pressure The first fire s in your appliance will be difficult to get going and keep going with little amount of heat being generated This is a result of the moisture being driven out of the fire brick Allow 30 to 40 hours of hot fires temperatures in excess of 500 F 260 C 600 F 316 C before your appliance will perform normally During the break in period the first 2 or 3 fires create only small hot fires using kindling this will allow the firebrick to cure Do not be alarmed if small hairline cracks develop in the firebrick This is a normal occurrence and does not pose a safety hazard The paint may also smell a little for the first few fires as it cures and you may wish to open a door or window to alleviate the smell To start a brisk fire is required Place loosely crumpled paper on the floor of the appliance and cover with dry kindling Open the air control fully by pulling the lever forward Light the paper and leave the door slightly ajar one inch 25 4mm until all kindling is burning To maintain a brisk fire a hot coal bed must be established and maintained Slowly add larger wood 2 x 4 size pieces Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between so that the primary air can flow directly into this trench and ignite the fuel above When the fire seems to be at its peak medium sized logs may be added Once these logs have caught fire
84. her information on how to handle a chimney fire After the chimney fire is out clean and inspect the chimney for stress and cracks prior to lighting another fire Also check combustibles around the chimney and the roof 85 1 W415 1226 B 05 26 14 30 8 4 8 5 CLEANING Both the chimney and the appliance must be Inspected cleaned if necessary at least once year For serious wood burners chimney cleaning must be done as needed to avoid chimney fires the venting systems for controlled combustion appliances may need cleaning as often as once a month These rates however depend on the burning habits of the individual operating the appliance For example it is possible to clog a solid fuel appliance chimney in a few days if slow smoldering fires are burned and the chimney is cold NOTE Appliances burned consistently without hot fires may result in significant creosote accumulations in the chimney Certain items and considerations are important in chimney cleaning Proper tools should be used including a brush specifically designed for chimney cleaning The chimney connector and dampers as well as the chimney should be cleaned 5 firebox and baffle system should be cleaned if needed The chimney should be inspected and repairs made if needed preferably by a qualified chimney sweep or mason 86 1 GLASS REPLACEMENT DO NOT USE SUBSTITUTE MATERIALS GLASS MAY
85. iment ou le service des incendies et suivez leurs directives e Cet appareil doit tre install par un installateur qualifi Risque de br lures L appareil doit tre teint et refroidi avant d effectuer un entretien e faites pas fonctionner tant que tous les composants ne sont pas compl tement install s e Ne laissez pas l appareil chauffer au point o des parties deviennent rougeoyantes N installez pas de composants endommages ou incomplets ni des composants substituts Risque de coupures et d raflures Portez des gants protecteurs et des lunettes de s curit lors de l installation Les bordures des pi ces de m tal peuvent etre coupantes Les enfants et les adultes devraient etre inform s des dangers que posent les temp ratures de surface lev es et se tenir distance afin d viter des br lures ou que leurs vetements ne s enflamment e Surveillez attentivement les jeunes enfants lorsqu ils sont dans la m me pi ce que l appareil Les jeunes enfants et autres sont plus risque de contacts accidentels causant des br lures Une barri re physique est conseill e lorsque qu il y a des individus risque dans la maison Pour emp cher l acc s un appareil ou un po le installez une barri re de s curit pour garder les jeunes enfants et autres individus risque hors de la pi ce et loign s des surfaces chaudes Les v tements et autres mat riaux combustibles ne doivent pas tre pos s sur le foye
86. ire plusieurs feux chauds pour liminer cette humidit LORS DE CE PROCESSUS NE SURCHAUFFEZ PAS L APPAREIL R DUISEZ L APPORT D AIR L APPAREIL SI CELUI CI OU LA CHEMIN E DEVIENNENT ROUGEOYANTS W415 1226 B 05 27 14 2 4 47 INFORMATION GENERALE NE PAS UTILISER CET APPAREIL SANS QUE LE PI DESTAL SOIT INSTALLE Votre appareil t afin de r pondre sp cifiquement aux exigences des normes d missions de particules de am ricaine de 1990 et a subi un nombre consid rable de tests dans des laboratoires canadiens et am ricains Ce syst me est le plus efficace le plus simple et sans probl me connu il fonctionne comme suit Pour favoriser la circulation ad quate des produits d chappement le syst me d vacuation de la chemin e de l appareil au bois doit tre concu de fa on minimiser les d viations Les syst mes d vacuation trop courts ou trop longs peuvent nuire la circulation des produits d chappement L appareil au bois et le syst me d vacuation de la chemin e doivent b n ficier d un apport d air comburant suffisant non seulement pour alimenter la flamme dans la chambre de combustion mais aussi pour favoriser un tirage ad quat Un bon quilibre entre l air comburant et le syst me d vacuation de la chemin e optimisera la performance de votre appareil L air comburant entre par deux ouvertures dans le plancher de l appareil qui peuvent tre ajust es par un contr le d
87. it BURNS contact the local building or fire authority and follow their guidelines Operate only with the door tightly closed DO NOT TOUCH GLASS UNTIL Burn wood behind the log retainer directly on the firebricks COOLED Do not use an elevated grate or otherwise raise the fire At least 14 square inches 90 3 square centimeters of outside air must NEVER ALLOW CHILDREN TO be admitted to the room or directly to the unit through 4 101 6 TOUCH GLASS diameter pipe Quality System Certified To ET LISTED This appliance is designed to burn natural wood only Higher efficiencies 9001 2008 Intertek and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut h ar d 6 Hearth Patio amp Barbecue Association Do not start a fire with chemicals or fluids such as gasoline engine oil etc Do not burn treated wood coal charcoal colored paper cardboard solvents or garbage Do not let the appliance become hot enough for any part to glow red KEEP THE STOVE TOP TEMPERATURE BELOW 700 371 C Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and damage Wolf Steel Ltd 24 Napoleon Rd Barrie ON LAM 0G8 Canada 103 Miller Drive Crittenden Kentucky USA 41030 Phone 705 721 1212 Fax 705 722 6031 www napoleonfireplaces com ask napoleonproducts co
88. ithout an appliance thermometer you are working blindly and have no idea of how the appliance is operating An appliance thermometer offers a guide to performance and should be located 14 356mm above the flue collar into the chimney connector Install the thermometer according to manufacturers instructions Can t get the fire going Use more kindling and paper Assuming the chimney and vent are sized correctly and there is sufficient combustion air the lack of sufficiently dry quantities of small kindling is the problem Thumb size is a good gauge for small kindling diameter Can t get heat out of the appliance One of two things may have happened The appliance door may have been closed prematurely and the appliance itself has not reached optimum temperature Reopen the door and or draft control to re establish a brisk fire The other problem may have been wet wood The typical symptom is sizzling wood and moisture being driven from the wood ASH LIP AIR CONTROL Draft is the force which moves air from the firebox up through the chimney The amount of draft in your chimney depends on the length and diameter of chimney local geography nearby obstructions and other factors including the amount of heat generated by the fire which can be measured by an appliance thermometer TEST Adjusting the air control regulates the temperature The draft can 477722 37 A be adjusted from low burn rate with the handle in fully to fast lt
89. knockout in the pedestal back or through a hole in the floor to line up with the hole in the pedestal base Use a fresh air kit Secure the 4 inch diameter aluminum liner by flaring the end once it is inserted through the 4 1 2 inch diameter hole in either the back or base of the pedestal If the air intake is through the floor the hole in the pedestal back must be covered with sheet metal to avoid cold air spillage into the room A cover plate is available from your Wolf Steel Ltd dealer Avoid cutting away floor joists wall studs electrical wires or plumbing Seal around the outside pipe with insulation to prevent drafts KNOCKOUT Attach the rear knockout plate located inside the ash pan for shipping purposes NOTE The 1450 can only have outside air connected to pedestal backplate Connection to bottom of pedestal not available W415 1226 B 05 26 14 11 4 0 INSTALLATION WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE FAILURE TO DO SO MAY RESULT IN FIRE ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR AND AIR SPACES BLOCKED PREVENTING THE FREE MOVEMENT OF COOLING AIR DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC SPACES BASEMENTS OR ABOVE THE ROOFING
90. l 6 stainless steel liner COMBUSTIBLE WALL T H CHIMNEY CONNECTOR FLOOR PROTECTOR CEECEE Lg Jed ga es 62 1A 415 1226 05 26 14 18 5 0 FINISHING 8 5 1 DOOR REMOVAL INSTALLATION Ensure to have a firm grip of the door at all times NOTE We recommend having two people perform this installation A Remove the bottom door hinge retainer by removing the screw as shown below then loosen the top door hinge retainer B Lift the door up and off of the hinge rod C Carefully place the door facedown on a soft surface to avoid scratching the paint D To install the door reverse these steps DOOR HINGE RETAINER i INGE SCREWS 5 1a DOOR ADJUSTMENT A Loosen the two hinge screws to adjust the horizontal levelling position of the door B Tighten the two hinge screws after the desired door position has been reached 96 5 16 LATCH BLOCK HOUSING ADJUSTMENT A Loosen the two screws of the latch block housing Shift the latch block housing up or down to suit the desired handle pitch HINT Shifting the latch block housing up will result in a lower handle pitch Shifting the latch block housing down will result in a higher handle pitch P
91. l Cet appareil n a pas t test avec un ensemble de b ches gaz non ventil es Afin de r duire le risque d incendie ou de blessure n installez pas d ensemble de b ches gaz non ventil es dans cet appareil Cet appareil peut devenir tr s chaud lorsqu il fonctionne Les mat riaux combustibles tels que le bois de chauffage les v tements mouill s etc plac s trop pr s de l appareil pourraient prendre feu faut emp cher les enfants et les animaux de toucher l appareil quand il est chaud La chemin e doit tre en bon tat et ne pas tre f l e Avant d installer cet appareil contactez le service du b timent ou le service d incendie de votre AVE RTI SS M NT municipalite et suivez leurs directives Faites fonctionner l appareil uniquement avec la porte bien ferm e LA VITRE CHAUDE CAUSERA Br lez le bois en arri re du pare b ches directement sur les briques DES BR LURES r fractaires N utilisez pas chenet et n essayez pas de sur lever le feu de quelque NE PAS TOUCHER LA AVANT QU ELLE AIT REFROIDI Au moins 14 pouces carr s 90 3 centim tres carr s d air ext rieur doit tre admis dans la pi ce ou directement dans l appareil par un conduit de 4 pouces NE JAMAIS LAISSER LES 101 6mm de diam tre ENFANTS TOUCHER LA VITRE Cet appareil a t con u pour br ler du bois naturel uniquement Vous obtenez une meilleure efficacit et des missions plu
92. l check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Consult with your dealer regarding special connection components available for use for wall pass throughs Use only parts that have been tested and listed for use in a wall pass through MAINTAIN 2 COMBUSTIBLE STORM OUTSIDE WALL COLLAR SECTION FLASHING LISTED CHIMNEY PIPE INSULATED T COMBUSTIBLE CEILING WALL SPACER FOR OUTSIDE WALL CHIMNEY CONNECTOR FLOOR COMBUSTIBLE PROTECTOR WALL W415 1226 B 05 26 14 1 4 1 5 TYPICAL EXISTING MASONRY You also install your using your existing masonry do so follow the SEMEN guidelines below Use a factory built thimble or construct your own brick thimble If you are T using masonry it is important that it ee l be built in compliance with the specifications of the Building Code in your region It must RAFTER CE LH normally be lined with fire clay bricks metal EAVE or clay tiles sealed together with fire cement CLEARANCE WITH FIRESTOP LT I Round flues are the most efficient The 7 maximum flue size is 8 203 2 x 8 203 2mm square or 6 152 4mm round CEILING JOIST For greater diameters it is necessary to 1 1 CLEARANCE instal
93. le de combustion pleinement ouvert ou peine ferm FR 7 3 2 FEU CONTINU Chargez vos b ches de dimension plus grande de fa on compacte pour emp cher les flammes de s infiltrer compl tement Apr s 30 minutes environ selon la grosseur de la charge fermez le contr le de combustion en v rifiant que le feu ne se soit pas teint 7 4 SURCHAUFFEZ PAS L APPAREIL Une surchauffe peut se produire A en br lant de grandes quantit s de bois de dimension r duite tel que des rebuts de bois de meuble des palettes ou du bois trait B en brulant vivement des grandes quantit s de bois avec le controle de combustion lt HIGH gt enti rement ouvert pendant de longues p riodes une ou deux heures C en faisant fonctionner l appareil lorsque la porte de la chute cendres est ouverte ou lorsque le joint d tanch it de la porte principale est d fectueux T ENFUMAGE Un appareil install convenablement ne devrait pas fumer Si le v tre fume v rifiez les points suivants Est ce que la chemin e a pu se r chauffer suffisamment Est ce que le passage de la fum e est bloqu soit dans la chemin e soit dans le conduit de raccordement soit dans l appareil Est ce que la pi ce est trop herm tique et que la prise d air comburant n est pas raccord e sur l ext rieur Es sayez avec une fen tre partiellement ouverte Est ce que le flot de fum e est restreint par un tuyau horizontal trop long ou par
94. longtemps apr s l allumage initial Un thermom tre sur le conduit de raccordement ou sur le dessus de l appareil serait utile Faites toujours fonctionner l appareil avec le couvercle de chute cendres bien install E CAS DE FEU DE CHEMIN E Ayez un plan d vacuation bien compris de tous et d signez un lieu de rassemblement l ext rieur Pr parez vous vacuer les lieux pour assurer la s curit de chacun Fermez la prise d air de l appareil Appelez votre service d incendie Ayez un extincteur sous la main Contactez les autorit s locales pour savoir quoi faire en cas de feu de chemin e Apr s que le feu de chemin e est teint et avant d allumer un autre feu nettoyez et inspectez la chemin e pour des signes de d t rioration ou des fissures V rifiez egalement les mat riaux combustibles autour de la chemin e et du toit 85 1 W415 1226 B 05 27 14 70 8 4 DE LA La chemin e et l appareil doivent tre inspect s et nettoy s s il y a lieu au moins une fois l an cas d utilisation fr quente du chauffage au bois le nettoyage de la chemin e doit etre au besoin pour eviter des feux de chemin e Les systemes d vacuation des appareils combustion controlee peuvent n cessiter un nettoyage aussi fr quent qu une fois par mois Cependant cette fr quence d pend des habitudes de chauffage de la personne qui utilise l appareil A titre d exemple
95. m 10 00 Or T Vn gt gt D E A W415 1226 B 05 26 14 TABLE 5 NOTE camera icon indicates video tutorials available as additional reference visit http www napoleonfireplaces com category product support support centre 1 0 INSTALLATION OVERVIEW 2 0 INTRODUCTION 2 1 DIMENSIONS 2 3 SPECIFICATIONS 2 2 GENERAL INSTRUCTIONS 2 4 GENERAL INFORMATION 2 5 RATING PLATE INFORMATION 3 0 PRE INSTALLATION PREPARATION 3 1 APPLIANCE PLACEMENT 3 2 CLEARANCE TO COMBUSTIBLES 3 3 FLOOR PROTECTION 3 4 OUTSIDE AIR 3 4 1 OUTSIDE AIR MOBILE HOME 4 0 INSTALLATION 4 1 CHIMNEY 4 1 1 CHIMNEY CONNECTION 4 1 2 SECTIONS 4 1 3 TYPICAL THROUGH THE CEILING 4 1 4 TYPICAL THROUGH THE WALL 41 5 TYPICAL EXISTING MASONRY 5 0 FINISHING 5 1 DOOR REMOVAL INSTALLATION 5 2 HANDLE AND DOOR SERVICE AND INSTALLATION 5 3 BRICKS AND BAFFLE INSTALLATION 5 4 ASH DRAWER ADJUSTMENT 6 0 OPTIONAL KIT INSTALLATIONS 6 1 BLOWER KIT INSTALLATION 6 11 BLOWER INSTALLATION 6 2 DOOR TRIM KIT 7 0 OPERATION 74 AIR CONTROL 7 2 FIRE EXTINGUISHERS SMOKE DETECTORS 73 LIGHTING A FIRE 7 84 FLASH FIRE 7 3 2 EXTENDED FIRE 7 4 SMOKING 8 0 MAINTENANCE 8 1 ASH REMOVAL PROCEDURES 8 2 CREOSOTE FORMATION AND REMOVAL 8 3 RUNAWAY OR CHIMNEY FIRE 8 4 CHIMNEY CLEANING 8 5 GLASS REPLACEMENT 8 6 SECONDARY AIR TUBE REPLACEMENT 8 7 CARE OF GLASS 8 8 CARE OF PLATED PARTS 8 9 WOOD 9 0 REPLACEMENTS 10 0 TROUBLESHOOTING 11 0 WARRANTY 12 0
96. mat riel combustible ou un espace ferm tels un grenier un entretoit ou un placard S il passe travers un mur un plafond ou dans une chemin e de ma onnerie utilisez soit des composants de chemin e con us pour cet usage ou des moyens acceptables de l autorit comp tente locale Cet appareil doit tre raccord A Une chemin e qui se conforme aux exigences des chemin es pr fabriqu es de type HT r sidentiel ou B Une chemin e en ma onnerie avec chemisage int gral conforme aux codes et aux exigences EMBOUT M LE Ventilez le po le dans une chemin e de ma onnerie DU CONDUIT ou dans une chemin e isol e en acier inoxydable VERS LA DE RACCOR certifi e Le tuyau de raccordement de 6 152 4mm BUSE DE DEMENT de diam tre doit tre aussi court et aussi droit L APPAREIL que possible Le raccordement la chemin e de DIRECTION doit se faire l aide dun manchon DES GAZ DE m tallique ou de ciment en place COMBUSTION 58 1B W415 1226 B 05 27 14 54 4 1 2 AJOUT DE SECTIONS Ajoutez des sections de chemin e selon les instructions d installation des manufacturiers La chemin e doit d passer le toit dau moins 3 0 9m de son point de contact avec la toiture et 2 0 6m de tout mur toit ou difice se trouvant l int rieur d une distance horizontale de 10 3 1m LESS THAN 10 FEET 3m FR Y ER 2 FT 0 6 IT 2 FT 0 6m MIN RIDGE 3
97. mit e sa discr tion gratuitement Apr s les dix premi res ann es NAPOL ONG fournira les pi ces de rechange 50 du prix de d tail courant Toutes les pi ces remplac es au titre de la garantie seront couvertes pour une p riode de 90 jours partir de leur date d installation Le fabricant peut exiger que les pi ces d fectueuses ou les produits soient retourn s ou que des photos num riques soient fournies pour valider la r clamation Les produits retourn s doivent tre exp di s port pay au fabricant pour une inspection en usine Si un produit est d clar d fectueux le fabricant le r parera ou le remplacera Avant d exp dier votre appareil ou les pi ces d fectueuses votre d taillant doit obtenir un num ro d autorisation Toute marchandise exp di e notre usine sans autorisation sera refus e et retourn e l exp diteur Les co ts d exp dition ne sont pas couverts par cette garantie Des frais de service suppl mentaires peuvent tre appliqu s si vous cherchez obtenir des services au titre de la garantie aupr s d un d taillant Les indemnit s de main d oeuvre au titre de la garantie s appliquent uniquement pour le remplacement d une pi ce garantie Les frais de d placement de tests de diagnostic d exp dition et autres frais aff rents ne sont pas couverts par cette garantie TOUTES LES SP CIFICATIONS ET LES CONCEPTIONS SONT SUJETTES MODIFICATIONS SANS PR AVIS EN RAISON DES AM LIORATIONS CONS
98. n une angle du poign e plus bas D placement vers le bas r sultat en une angle du poign e plus haut ANGLE DE LA POIGN E EN POSITION FERM E W415 1226 B 05 27 14 59 ee 5 2 INSTALLATION DE LA POIGNEE DE PORTE ET DE LA PORTE FAIRE FONCTIONNER CET APPAREIL AVEC LES PORTES OUVERTES OU ENTROUVERTES CREE UN RISQUE D INCENDIE DE CHEMINEE OU DU DOMICILE NE FRAPPEZ PAS ET NE CLAQUEZ PAS LA PORTE N ENLEVEZ JAMAIS LA PORTE LORSQUE L APPAREIL EST CHAUD A Retirez les deux vis qui fi xent le bloc de loquet la porte B Tirez le poign e vers l int rieur de la porte et retirez les composants du bloc de loquet puis retirez le bloc de loquet et le poign e Remplacez les composants us s ou endommag s C Pour r installer la poign e de porte prenez le bloc de loquet et le poign e de porte puis alignez les trous de vis du haut et du bas avec la porte comme illustr D Serrez l g rement la vis sup rieure puis installez les deux goupilles comme illustr E Pour installer le ressort glissez le dans le bas du bloc de loquet puis installez la vis Appliquez une petite quantit de graisse haute temp rature sur le ressort avant l installation ASTUCE Comprimez le ressort l aide d un tournevis t te plate cela facilite l installation de la vis comme illustr ci dessous F Afin d assurer une bonne installation le support de la poign e doit avoir la possibilite de demeurer dans u
99. ne position vers le haut De plus le support de la poign e doit sengager sans probleme dans le foyer A s DE LOQUET POIGN E PINGLES m gt PINGLES m e RESSORT M RESSORT W415 1226 B 05 27 14 60 S 53 INSTALLATION DES BRIQUES DES DEFLECTEURS EN FIBRE L UTILISATION DE L APPAREIL SANS LES D FLECTEURS PEUT CAUSER DES TEMP RATURES EXCESSIVES QUI POURRAIENT ENDOMMAGER L APPAREIL LA CHEMINEE ET L ENCEINTE Une fois l installation de l appareil et du tuyau de raccordement compl t e mettez les briques en place en proc dant tel qu illustr pr c demment A B place Installez les briques de plancher de l arri re vers l avant de l appareil Avant d installer les briques arri re desserrez la vis du support et assurez vous qu il a t d plac vers l avant Installez les six briques sur la paroi arri re en les faisant pivoter sous le support briques puis resserrez la vis Installez les premier deux rangs de briques de comme illustr e au dessous Pivotez les d flecteurs en fibre sa place avec la support de brique en bas et vers l ext rieur de l appareil Glisser le premier rang de briques sa place pour soutenir les d flecteurs Le d flecteur doit se reposer plat sur la rang e ext rieure de briques et aussi sur la bride l cran du collecteur Assurez vous que les d flecteu
100. ners nor chipping on porcelain enamel parts nor any venting components used in the installation of the appliance This warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to the President s Lifetime Limited Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part s After the first year NAPOLEON will not be responsible for installation labour or any other costs or expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the President s Lifetime Limited Warranty NAPOLEON s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON wood appliance and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEONG neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product N
101. ng prices and policies replacement parts Normally all parts can be ordered through your Authorized dealer distributor FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM FAILURE TO POSITION THE PARTS When ordering replacement parts always give the following information IN ACCORDANCE WITH THIS e Model amp Serial Number of appliance MANUAL OR FAILURE TO USE ONLY Installation date of appliance PARTS SPECIFICALLY APPROVED e Part number WITH THIS APPLIANCE MAY e Description of part RESULT IN PROPERTY DAMAGE OR e Finish PERSONAL INJURY IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER m COMPONENTS ru e esros e mooo eene wa Joes wu 6 asp BRICK 1 25 3 9 31 8mm 76 2mm x 228 6mm MOLDED BRICK 1 25 4 5 4 5 31 8 114 3mm x 190 5mm BRICK 1 25 x 4 5 x 8 5 31 8mm x 114 3mm x 216mm W415 1226 B 05 26 14 5 75 5 R SSO E C C A 36 10 00 TROUBLESHOOTING TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE WHEN CHECKING CONNECTIONS INSTALLING JUMPER WIRES FOR TEST PURPOSES ONLY OR REPLACING COMPONENTS UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT PROBLEM SOLUTION Can t get
102. nstall an optional blower kit EP65 that comes complete with a variable speed switch to turn the blower on and off as well as adjusting the blower speed and a thermostatic sensor to thermally activate the blower Drywall dust will penetrate into the blower bearings causing irreparable damage Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not covered by the warranty policy Use of the blower increases the output of heat 6 1 1 BLOWER INSTALLATION A Ensure the thermal disc bracket is in the correct position refer to Figure 1 B Remove the knock out from the back of the appliance C Install the blower and housing as shown using the 4 screws supplied refer to Figure 2 D Loosen the thermal disc bracket 2 screws and slide the bracket until the thermal disc is touching the rear of the firebox and secure ITHERMAL DIS e BRACKET C 415 1226 05 26 14 24 SW 6 2 DOOR TRIM KIT Open the door of the appliance B Remove the right side screw holding the top door hinge retainer in place C Place one shim against the door on the left side D Set the trim on the top of the door align to the holes and secure TOP DOOR HINGE RETAINER W415 1226 B 05 26 14 25 7 0 OPERATION ALWAYS OPE
103. ompl tement ouvert Assurez vous que le contr le d air n est pas obstru e Le contr le d air doit possiblement tre r duit Assurez vous que le couvercle de la chute cendres est bien install s il en est muni V rifiez que le joint d tanch it de la porte est bien herm tique Le bois est peut tre extr mement sec Le contr le d air peut tre trop ferm Faites des feux plus chauds et plus petits Utilisez du bois bien sec L appareil n a peut tre pas atteint sa temp rature Assurez vous que la soufflerie est bien branch e L enlevez loquet de la porte et appliquez un anti grippant au les ressort Remontez 77 11 07 GARANTIE Les produits NAPOL ONG sont fabriqu s conform ment aux normes strictes du Certificat d Assurance de Qualit ISO 9001 2008 mondialement reconnu Les produits NAPOL ON sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Une fois assembl chaque appareil est soigneusement inspect par un technicien qualifi avant d tre emball pour garantir que vous le client recevez le produit de qualit dont vous vous attendez de NAPOL ONG GARANTIE VIE LIMIT E DU PR SIDENT DES APPAREILS BOIS NAPOLEON Les mat riaux suivants et la fabrication de votre nouveau po le bois Napol on sont garantis contre les d fauts tant que vous en tes le propri taire Ceci couvre la chamb
104. on lente avec la manette compl tement enfonc e et une combustion rapide avec la manette compl tement tir e Un tirage inad quat peut causer des refoulements de fum e RENE dans la pi ce via l appareil et les points de raccordement des conduits peut galement causer un blocage U de la chemin e Un tirage trop grand provoquera des temp ratures excessives dans l appareil des composants de l appareil ou des conduits de raccordements qui rougeoient ou une combustion incontr lable qui peut causer un feu de chemin e ou des dommages permanents l appareil Ne faites pas fonctionner l appareil pendant plus de 30 minutes avec le contr le d air HIGH compl tement ouvert compl tement ouvert EXTINCTEURS ET D TECTEURS DE FUM E Toutes les maisons poss dant un appareil combustible solide devraient poss der au moins un extincteur d incendie dans un emplacement central connu de tous et au moins un d tecteur de fum e plac dans la pi ce ou l appareil est situ Si l alarme se d clenche corrigez la cause mais ne d sactivez pas ou ne relocalisez pas le d tecteur de fum e 91 1 W415 1226 05 27 14 7 3 6 ALLUMER UN FEU 7 3 1 FEU ECLAIR Un feu eclair est un petit feu qui brule rapidement quand vous n avez pas besoin de beaucoup de chaleur Une fois que votre bois d allumage est bien allum chargez trois buches par dessus de fa on tr s lache Faites bruler avec le contr
105. p Cooling call 705 721 1212 e Grills call 705 726 4278 napoleonproducts com Fireplace Inserts Charcoal Grills Gas Fireplaces e Waterfalls e Wood Stoves Heating amp Cooling e Electric Fireplaces Outdoor Fireplaces e Gourmet Grills INSTALLATEUR LAISSEZ CE MANUEL AVEC L APPAREIL PROPRIETAIRE CONSERVEZ CE MANUEL POUR CONSULTATION ULTERIEURE NE LAISSEZ PAS LES ENFANTS OU AUTRES INDIVIDUS A RISQUE SEULS A PROXIMITE DE L APPAREIL INSTRUCTIONS Ne NAPOLEON DINSTALLATION ET FOYERS DE QUALITE D OPERATION HOMOLOGU SELON LES NORMES D MISSION DE PARTICULES DE L AGENCE DE PROTECTION DE L ENVIRONNEMENT AM RICAINE E P A DE JUILLET 1990 40 C F R SECTION 60 ET DU D PARTEMENT DE LA QUALIT DE L ENVIRONNEMENT DE L TAT D OREGON D E Q PAR E E M C CES PO LES ONT TESTES ET HOMOLOGU S PAR INTERTEK TESTING SERVICES SELON LES NORMES CSA B366 2 ULC S627 UL 1482 51 54 amp 59 MODELES SUR PIEDESTAL CONSIGNES DE SECURITE AVERTISSEMENT SI ces Instructions ne sont pas suivies la lettre un incendie ou une explosion pourraient s ensuivre causant des dommages mat riels des blessures corporelles ou des pertes de vie Une installation non conforme des ajustements des alt rations un service ou un entretien inad quats peuvent causer des dommages mat riels des blessures corporelles et des pertes de vie Veuillez lire le manuel en entier avant d installer et d utiliser cet apparei
106. plying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliance or MALE END OF B A code approved masonry chimney with a flue CONNECTOR liner Vent the stove into a masonry chimney or an on OR CHIMNEY approved insulated solid fuel stainless steel chimney ARPEIANGE PIPE with as short and straight length of 6 152 4 diameter chimney connector as possible Connection FLUE GAS to a masonry chimney must be by a metal or masonry DIRECTION thimble cemented in place 58 1B 415 1226 05 26 14 14 4 1 2 SECTIONS Add chimney sections according to the manufacturers installation instructions The chimney must extend at least 3 feet 1m above its point of contact with the roof and at least 2 feet 0 6m higher than any wall roof building or obstacle within 10 feet 3m horizontally LESS THAN 10 FEET 3m Y ERAT 0 6m 2 FT 0 6m MIN RIDGE MIN 3 FT 1m 4 10 FT 3m SS TO NEAREST Geh i ROOFLIN I LESS THAN 10 FEET 10 FT 3m 4 86 am 2 FT 0 6m SE m MIN I MIN L Ji FN FLAT ROOF wit 59 1B W415 1226 B 05 26 14 4 1 3 TYPICAL THROUGH THE CEILING NOTE The chimney must be supported at the ceiling or roof so that it s Move the stove into position with the flue centered midpoint between two joists
107. porte l g rement entrouverte un pouce 25 4mm jusqu ce que tout le bois d allumage soit enflamm Pour maintenir un feu vif un lit de braises doit se former et tre entretenu Lentement ajoutez des morceaux de bois plus gros 2 x 4 Posez les morceaux dans le lit de braises parall lement l arri re de l appareil tout en gardant une tranch e peu profonde entre les morceaux de bois Ainsi l air comburant primaire circulera directement dans la tranch e et allumera le bois Lorsque la flamb e semble son maximum des b ches de dimensions moyennes peuvent tre ajout es Une fois que ces morceaux ont pris feu fermez la porte doucement Le fait de fermer la porte imm diatement apr s le chargement entrainera une diminution de temp rature dans la chambre de combustion et se traduira par une combustion insatisfaisante Rappelez vous qu il est plus efficace de br ler des morceaux de bois de dimensions moyennes feu vif et de recharger plus souvent que d alimenter l appareil avec de gros morceaux qui produiront un feu languissant et inefficace qui salira la vitre W415 1226 B 05 27 14 66 7 1 7 2 Une fois que la porte est ferm e vous observerez changement dans le comportement des flammes Elles deviendront plus petites et plus paresseuses parce que le volume d oxyg ne qui entre dans la chambre de combustion est moindre Cependant les flammes sont plus efficaces Elles continueront d etre paresseuses mai
108. r ou proximit En des temperatures lev es le foyer devrait etre plac loin des endroits passants et loin des meubles et des rideaux Les objets plac s devant l appareil doivent etre gard s une distance d au moins 48 1219 2 de l avant de l appareil e Assurez vous de disposer de mesures de s curit ad quates pour emp cher les jeunes enfants de toucher aux surfaces chaudes M me une fois que le foyer est teint la vitre et ou le pare tincelles demeureront chauds pendant un temps prolong e Consultez votre d taillant local de foyer pour conna tre les grillages de s curit et les crans offerts pour prot ger les enfants des surfaces chaudes Ces grillages de s curit et ces crans doivent tre fix s au plancher e Les grillages de s curit ou crans enlev s pour faire l entretien devront tre remis en place avant d utiliser l appareil e Cet appareil ne devra tre modifi en aucun cas Cet appareil ne doit pas etre raccord au conduit d une chemin e desservant un autre appareil de chauffage combustible solide e Ne pas op rer l appareil lorsque la porte vitr e est enlev e fissur e ou bris e Le remplacement de la vitre devra tre effectu par un technicien de service certifi ou qualifi e frappez pas et ne claquez pas la porte vitr e de l appareil e faites fonctionner l appareil qu avec les portes compl tement ferm es e Seules les portes fa a
109. re de combustion l changeur de chaleur la vitre en c ramique cassure thermique seulement les pi ces plaqu es or contre le ternissement les composants en porcelaine maill e les moulures d extrusion en aluminium d flecteurs vortex le tiroir cendres et les pi ces moul es en fonte Les composants lectriques 110 V et les pi ces soumises l usure tels que la soufflerie l interrupteur thermique les interrupteurs l installation lectrique les briques r fractaires l attache du d flecteur en acier inoxydable tuyaux d air secondaires et les joints d tanch it sont couverts et Napol on fournira gratuitement les pi ces de rechange durant la premi re ann e de la garantie limit e Les co ts de main d oeuvre relatifs aux r parations garanties sont couverts gratuitement durant la premi re ann e Cependant les travaux de r paration n cessitent l approbation pr alable d un repr sentant autoris de la compagnie Les co ts de main d oeuvre la charge de NAPOL ONG sont bas s sur un programme de tarifs pr d termin s et tout travail de r paration doit tre accompli par l entremise d un d taillant autoris NAPOL ONG Les pi ces telles que les briques r fractaires et les d flecteurs devraient tre retir es occasionnellement par l op rateur dans le cadre d un entretien normal Par cons quent les co ts de main d oeuvre associ s au remplacement de l une de ces pi ces ne sont pas couverts par la garantie
110. rning wood will flow back into the fire chamber Each joint in the chimney connector must be secured with at least three sheet metal screws For installation of your chimney connector the following recommendations may be useful connector must be short straight For optimum performance it is recommended that all horizontal runs have a minimum 1 4 6 4mm rise per foot 0 9m with the upper end of the section toward the chimney For safe and proper operation of the appliance see INSTALLATION instructions To insure good the total horizontal length of the connector should never exceed 8 2 4m to 10 3 1m In the case of vertical installation the total length of the connector can be longer and connected without problem to the at the ceiling level There should never be more than two 90 elbows the entire connector and chimney system Never start with a 90 elbow Always go up vertically for at least 2 feet 0 6m from the flue collar before using a 90 elbow The connector must not pass through any combustible material nor may it pass through a concealed space such as an attic roof space or closet If passing through a wall ceiling or into a masonry chimney use either chimney components listed for that specific use or means acceptable to local authorities having jurisdiction over the installation This appliance must be connected to A A chimney com
111. rs sont compl tement pouss s vers l arri re de la chambre de combustion en laissant un espace minimum d un pouce 25mm l avant Ceci permettra aux r sidus des gaz de combustion d tre vacu s de la chambre de combustion Installez la reste des briques devant l ouverture de l appareil comme illustr e au dessous E NOTE Ne faites pas fonctionner l appareil si le d flecteur brique ou l cran du collecteur n est pas en W415 1226 B 05 27 14 51 54 amp 59 Tous les briques r fractaires sont de 1 1 4 pouces 32mm d paisseur DIMENSIONS PART NO DE PIECES DIMENSIONS PART NO DE PIECES DE BRIQUE sr s m 4 1 2 x 9 W090 0001 W090 0001 W090 0015 2 1 4 x 9 W090 0018 W090 0018 W090 0018 114mm x 229mm x12 18 20 57mm x 229mm x1 x1 x1 3 x 9 Moul e W090 0002 W090 0002 W090 0002 1 3 4 x 43 4 W090 0216 W090 0216 W090 0216 6mm x 229mm 2 2 2 64mm x 121mm X1 X1 X1 c 412 x412 W090 0003 W090 0003 2 1 2 x 4 1 2 W090 0016 w090 0016 W090 0016 114 x 144mm X2 X2 64mm x 114mm X1 X1 X1 250 W090 0166 W090 0166 W090 0166 11 27 41 27 W090 0017 W090 0017 090 0017 76mm x 229mm 2 X2 X4 38mm x 114mm X1 X1 X1 4 1 2 x 9 Entaill e W090 0207 W090 0207 W090 0207 4 1 2 x 8 1 2 W090 0210 W090 0210 W090 0210 114mm x 229mm X1 X1 X1 114mm x 216mm X3 X3 X3 4 1 2 x 9 Entaill e W090
112. s basses avec du bois dur s ch Syst me de qualit certifi l air quavec du bois resineux ou vert ou du bois dur fraichement coupe N allumez pas votre feu l aide produits chimiques de liquides tels que 1517 de l essence de l huile moteur etc Barones eegen 9001 2008 Intertek Ne brulez pas de bois trait de charbon de bois de charbon de papier de couleur de carton de solvant ou de d chets Ne laissez pas l appareil chauffer au point o des parties deviennent rougeoyantes GARDEZ LA TEMP RATURE SUR LE DESSUS DE L APPAREIL SOUS 700 371 C Toute tentative de d passer les d bits maximaux de chaleur tels que mentionn s dans les sp cifications de conception pourrait provoquer la distorsion de l acier et causer des dommages Wolf Steel Ltd 24 Napoleon Rd Barrie ON LAM 0G8 Canada 103 Miller Drive Crittenden Kentucky USA 41030 T l phone 705 721 1212 T l copieur 705 722 6031 www napoleonfoyers com ask napoleonproducts com 10 00 127 415 1226 05 27 14 42 TABLE DES MATIERES SS NOTE L ic ne du camera indique que les vid os sont disponibles comme une r f rence suppl mentaire visitez http www napoleonfireplaces com category product support support centre 1 0 VUE D ENSEMBLE DE L INSTALLATION 43 2 0 INTRODUCTION 44 2 1 DIMENSIONS 45 2 3 SP CIFICATIONS 46 2 2 IN
113. s firebricks and baffles should routinely be removed by the operator as part of the regular service and therefore any warranty replacement of these parts does not qualify for any labour allowances Construction of models vary Warranty applies only to components included with your specific appliance CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only Registering your warranty is not necessary Simply provide your proof of purchase along with the model and serial number to make a warranty claim Provided that the purchase was made through an authorized NAPOLEON dealer your appliance is subject to the following conditions and limitations Warranty coverage begins on the date of original installation This factory warranty is non transferable and may not be extended whatsoever by any of our representatives The wood appliance must be installed by an authorized service technician or contractor Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasive and chemical clea
114. s redeviendront plus grandes d s que les briques r fractaires auront t compl tement r chauff es et que la chemin e deviendra plus chaude produisant ainsi un meilleur tirage A ce stade les grandes flammes que vous observez lorsque la porte est ouverte tirent inutilement l air rechauffe de la piece dans la chemin e une situation qui est certes ind sirable C est pourquoi il faut toujours faire fonctionner l appareil avec la porte compl tement ferm e lorsque les morceaux de bois de dimensions moyennes sont enflamm s Vous pouvez maintenant ajouter de plus gros morceaux de bois et faire fonctionner l appareil normalement Une fois que l appareil est compl tement r chauff il br lera tr s efficacement en laissant chapper que tr s peu de fum e par la chemin e Il y aura un lit de braises orang es dans la chambre de combustion et les flammes secondaires effleureront le dessous des d flecteurs sup rieurs Vous pouvez sans crainte remplir la chambre de combustion avec du bois jusqu au haut de la porte de chargement et vous obtiendrez de meilleures flamb es si vous maintenez la temp rature du tuyau de l appareil entre 250 F 120 C et 450 F 270 C Un thermom tre de surface vous aidera mieux contr ler la temp rature Sans thermom tre vous travaillez l aveuglette sans aucune id e r elle du fonctionnement de votre appareil Un thermom tre d appareil vous donne une r f rence quant la performance de votre appar
115. stallez le comme d crit pr c demment l tape E Serrez les crous et les boulons G R installez les d flecteurs et les briques H Pour r installer les crans arri re et lat raux r f rez vous aux tapes A et B des instructions sur le retrait NOTE POUSSEZ LE D FLECTEUR ENTIEREMENT VERS LARRIERE DE LA CHAMBRE DE COMBUSTION LAISSANT UN ESPACE MINIMAL DE 1 PO 25 4 A L AVANT CECI AUX FUMEES DE BIEN ETRE EVACUEES DE LA CHAMBRE DE COMBUSTION W415 1226 05 27 14 72 8 7 8 8 SOINS DE LA Si vous ne nettoyez pas les d p ts regulierement la vitre risque de rester marqu e en permanence Normalement un feu tr s chaud maintiendra la vitre propre Les raisons les plus fr quentes pour lesquelles la vitre se salit sont trop UNE SURFACE VITREE CHAUDE peu de combustible est utilis pour r chauffer suffisamment l appareil l utilisation PEUT CAUSER DES BR LURES de bois vert ou humide le contr le de combustion est trop ferme creant une insuffisance d air pour r aliser une combustion compl te S il est n cessaire de VITREE AVANT D Y TOUCHER nettoyer la vitre utilisez un linge doux avec un nettoyeur sans abrasif NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE NE PAS NETTOYER LORSQU ELLE EST CHAUDE Nettoyez la vitre avec un VITREE nettoyeur recommand apr s les dix premi res heures de fonctionnement Par la suite nettoyez aussi souvent
116. t side and upwards on the left side then pull the ash drawer out from the pedestal B To change the spacing between the ash drawer cover and pedestal loosen the side adjustment screws both sides and position to the desired space then tighten the screws HROM 1 SIDE ADJUSTMENT SLOTS SCREWS DRAWER DISCONNECT PEDESTAL ASH DRAWER ASH DRAWER HOUSING NOTE Always ensure the ash pan is completely cool prior to removing it from the ash drawer W415 1226 B 05 26 14 23 8 6 0 OPTIONAL KIT INSTALLATIONS 6 1 BLOWER KIT INSTALLATION RISK OF FIRE AND ELECTRICAL SHOCK TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE USING NON LISTED ACCESSORIES BLOWERS DOORS LOUVRES TRIMS GAS COMPONENTS VENTING COMPONENTS ETC COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION ENSURE THAT THE FAN S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN THE POWER CORD BENEATH THE APPLIANCE THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 51 5 Provisions have been made on the stove to i
117. t extr mement herm tique et est quip d une alimentation directe d air comburant exclusive ensemble optionnel un dispositif de s curit qui emp che les coulements afin de garder votre maison exempte de monoxyde de carbone advenant un refoulement de chemin e ou une pression n gative interne Le s premier s feu x de l appareil sera seront difficile s partir et maintenir tout en produisant qu un peu de chaleur Ceci est le r sultat de l humidit manant des briques r fractaires Apr s 30 40 heures de fonctionnement feu vif des temp ratures d passant 500 F 260 C 600 F 316 C votre appareil fonctionnera de fa on normale Durant la p riode de rodage les premiers 2 ou 3 feux ne faites que des petits feux chauds en utilisant du bois d allumage cela permettra la brique de se conditionner Ne vous inqui tez pas si de petites fissures apparaissent dans les briques r fractaires Cela est normal et ne pose aucun danger la s curit La peinture peut galement produire de l g res manations pendant les premiers feux cause du processus de cuisson vous devrez ouvrir une porte ou une fen tre pour chasser les odeurs l allumage un feu vif est requis Placez des morceaux de papier grossi rement chiffonn s sur le plancher de l appareil et couvrez les de bois d allumage Ouvrez compl tement le contr le de combustion en le d plagant compl tement droite Allumez le papier et laissez la
118. tested so that without any protection the floor will not overheat USA 16 406 4mm 8 203 2mm 8 203 2 2 50 8 99 1 1 SIDES J BACK VENT L LT 3 4 OUTSIDE AIR IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR IS BLOCKED WITH ICE LEAVES ETC OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN OR DUE TO A STRONG EXHAUST FAN OPERATING ETC DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLIANCE COULD BE DRAWN INTO THE ROOM The following are signs that a fresh air kit may be required When there is combustion present Wood burns poorly smoke spills back draft takes place and your chimney does nol draw steadily In the winter there is too much condensation on the windows Opening a window seems to alleviate the above symptoms A ventilation system is installed in the house Other devices are present that exhaust house air The house has tight fitting windows and or is equipped with a well sealed vapour barrier If possible connect the air intake at the pedestal s back to outside air with a 4 inch 100 diameter fresh air kit available at your authorized dealer distributor Follow detailed instructions under Mobile Home Outside Air 3 4 1 OUTSIDE AIR MOBILE HOME Connection from the stove s air intake to outside air is mandatory in mobile homes only either through a hole in the wall to line up with the
119. ufflerie ou son compartiment Tout dommage caus par ce probl me ne sera pas couvert par la garantie L utilisation de la soufflerie accro t le d bit de chaleur 6 1 1 INSTALLATION DE LA SOUFFLERIE Assurez vous que le support du thermodisque est dans la position correcte voir la Figure 1 Enlevez la plaque de l arri re de l appareil Installez la soufflerie et son boitier tel qu illustr en Figure 2 en utilisant les quatre vis fournies 3 pP Desserrez le support de l interrupteur thermique deux vis et faites glisser le support vers l avant jusqu ce que l interrupteur thermique touche l arri re de la chambre de combustion et fixez Fig 1 SUPPORT DU THERMODISQUE W415 1226 8 05 27 34 7 THERMODISQUE GARNITURE DU PORTE Ouvrir la porte de l appareil Enl ver le vis aux c t gauche tenir le gond support sup rieure du porte en place Placer une rondelle contre la porte aux c t gauche A B C D Placer la garniture en haut du porte aligner les trous puis fixer en place FR GOND SUPPORT SUP RIEURE DU PORTE RONDELLE W415 1226 B 05 27 14 65 7 0 FONCTIONNEMENT FAITES TOUJOURS FONCTIONNER CET APPAREIL AVEC LA PORTE FERMEE ET VERROUILLEE SAUF DURANT L ALLUMAGE ET LE RAVITAILLEMENT PORTEZ TOUJOURS DES GANTS
120. venir les courants d air scellez le contour du conduit d air ext rieur avec de l isolant Fixez la plaque perfor e situ e dans le tiroir cendres pour fin de livraison NOTE La prise d air ext rieur sur le mod le 1450 ne peut tre branch e que sur la plaque arri re du pi destal Le branchement en dessous du pi destal n est pas possible W415 1226 B 05 27 14 51 4 0 INSTALLATION PORTEZ DES GANTS ET DES LUNETTES DE PROTECTION SUIVEZ ATTENTIVEMENT LES INSTRUCTIONS POUR L ASSEMBLAGE DE LA CHEMIN E ET DES AUTRES COMPOSANTS N CESSAIRES L INSTALLATION DE L APPAREIL TOUTE OMISSION POURRAIT CAUSER UN INCENDIE PARTICULIEREMENT SI DES MATERIAUX COMBUSTIBLES SONT TROP PRES DE L APPAREIL OU DE LA CHEMIN E ET QUE DES OUVERTURES D AIR SONT BLOQUEES EMP CHANT LA LIBRE CIRCULATION DE L AIR DE REFROIDISSEMENT N INSTALLEZ PAS LA PRISE D AIR EXTERIEUR DANS LE GARAGE LES PRODUITS D ECHAPPEMENT PROVENANT DES MOTEURS ESSENCE SONT DANGEREUX N INSTALLEZ PAS LA PRISE D AIR EXT RIEUR DANS UN GRENIER UN SOUS SOL OU AU DESSUS DU TOIT OU D AUTRES APPAREILS DE CHAUFFAGE DES VENTILATEURS ET DES CHEMINEES EVACUENT OU TIRENT DE L AIR CES MESURES REDUIRONT LES POSSIBILITES DE REFOULEMENT DE FUM E OU UNE INVERSION DU D BIT D AIR L ENTR E DE LA PRISE D AIR DOIT DEMEURER DEGAGEE DE FEUILLES DE D BRIS DE GLACE OU DE NEIGE ELLE DOIT ETRE DEGAGEE LORSQUE L APPAREIL FONCTIONNE AFIN QUE LA PIECE NE SOIT PAS PRIV E D AIR CE QUI
121. vous devrez ouvrir une fenetre ou une porte Pour vous assurer que la chute cendres est compl tement ferm e assurez vous que la porte se ferme avec un bruit sec d logeant ainsi tout ce qui pourrait tre coinc dans l ouverture cendres morceaux de charbon W415 1226 B 05 27 14 48 2 5 INFORMATION SUR PLAQUE D HOMOLOQATION Pour l emplacement de la plaque LISTED SOLID FUEL BURNING SPACE HEATER d h ir VUE 52 6 PO LE COMBUSTIBLE SOLIDE HOMOLOGU omologation voir l Section EE TESTED TO TEST SELON UL1482 ULC 5627 D ENSEMBLE DE L INSTALLATION a MODEL MOD LE EPA 1400 mene 868 1400 8g1400L 1402 1450 pss 1400 I 4001658 Ei m Cette illustration est titre de 4001659 WUSA T INSTALL AND USE ONLY IN POUR INSTALLATION ET r f rence seulement Consultez la ACCORDANCE WITHTHE UTILISATION GONFORMEMENT AUX CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIG la Ue h omo ati on pour o bt en r INSTRUCTIONS AND LOCAL AUX CODES LOCAUX DU B TIMENT MOBILE 27 q g BUILDING CODES HAUTEUR DE PLAFOND MINIMAL MINIMUM CLEARANCE OF 18 457mm TO THE CHIMNEY CONNEC nfo rm ati on r ci se tee E HEIGHT er BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION PROLONGEMENT RENSEIGNEZ VOUS AUPR S DES AUTORIT S LOCALES 3 air SERVICE DES INCENDIES AU SUJET DES RESTRICTION PROTECTION IF INST
122. woods or too green or freshly cut hardwoods Burning wet unseasoned wood can cause excessive creosote accumulation When this is ignited it can cause a chimney fire that may result in a serious house fire e This appliance is designed to burn natural wood only Do not burn treated wood coal charcoal coloured paper cardboard solvents or garbage e Burn wood directly on the firebricks Do not elevate grate or otherwise raise the fire e Do not store wood within appliance installation clearances or within the space required for re fueling and ash removal e Ashes must be disposed in a metal container with a tight lid and placed on a non combustible surface well away from the home or structure until completely cool e Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance Elevated temperatures on the wall or in the air above the appliance can cause melting discolouration or damage to decorations a T V or other electronic components 3 17D W415 1226 B 05 26 14 114 184mm 2 1 DIMENSIONS 123 4 324mm S1 ILLUSTRATED 71 4 06 184mm p 123 4 324mm 25 1 2 673mm 648mm 0 6 152mm 59 ILLUSTRATED W415 1226 B 05 26 14 6 2 3 SPECIFICATIONS SPECFICATONS s 56 139m 93 186m 93 325 WEIGHT BRICKS 215 lbs 98kg 250 lbs 113 4kg 285 Ibs 129kg WEIGHT OF BRICKS 110 Ibs 50kg 145