Home

Motion Sensing Coach Lights

image

Contents

1. Manual mode works only with x the ON TIME switch in the 1 5 or 10 position Before installation record the model number back on from back of fixture below Attach receipt in case of possible warranty issues 2013 HeathCo LLC 204028 02A Mode Switching Summary ON TIME Switch at 1 5 or 10 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode INSTALLATION Estimated Installation Time 30 minutes Items needed for installation not included e Phillips and flathead screwdrivers e Pliers e Wire strippers cutters e Safety glasses Light bulb e Silicone caulk For best performance mount the fixture about 6 feet 1 8 m above the ground WARNING Turn power off at circuit breaker or fuse 2 Remove Mounting Plate 1 Remove two nuts 3 Tighten screws finger tight This fixture comes with a universal mounting bracket It is pre assembled on the fixture to fit the majority of junction box applications However if the slots on the mounting plate do not line up with the junction box screw holes 1 Remove the fixture mounting screws from the mounting plate Note Do not remove the ground screw 2 Attach ground wire pigtai
2. Objetos que cambien r pidamente de tem peratura tales como ductos de calefacci n y acondicionadores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales dom sticos o el tr fico puedan activar el control Los objetos grandes cercanos y de colores resplandecientes que reflejan la luz del d a pueden hacer que el detector se apague No apunte otras luces hacia el detector ED 150 1 8m 9 1m Alcance Maximo Angulo de Cobertura Maxima 14 El detector es menos sensible al movimiento que se dirige directamente hacia l gt N P Movimiento Movimiento Detector Lo menos sensible Lo m s sensible 3 Camine por el rea de protecci n d n dose cuenta d nde est cuando la luz se prende Mueva la cabeza del detector hacia la izquierda o derecha para cam biar el rea de protecci n Nota Agarre s lo el detector como se muestra y gire todo el detector Cualquier otro m todo puede da arlo No lo force m s all de los puntos de parada Giro de la cabeza del detector para cambiar el rea de cobertura 4 Fije la sensibilidad SENS como ne cesite Demasiada sensibilidad puede aumentar las falsas alarmas Fije el per odo de tiempo ON TIME que laluz debe quedarse prendida despu s de detectar movimiento 1 5 o 10 minutos 204028 02 Alcance Angulo de detecci n Carga El ctrica Capacidad del Detector ESPECIFICACIONES Hasta
3. la commande doit tre branch e uninter FONCTIONNEMENT Temps en circuit En fonction jour nuit 5 secondes X x 1 5 ou 10 min X au choix amanecer x Revient au mode automatique au lever du soleil Note Apr s mise en circuit attendre enfiron 1 minute pour que l talonnage du circuit soit compl t ESSAI Amenerenpositiond essai ON TIME TEST l interrupteur de temps en circuit ON TIME O du bas du d tecteur TEST 1 510 MIN AUTOMATIQUE Amener l interrupteur de ON TIME temps en circuit ON TIME fe lt lt gt la position correspondant a 1 5 ou 10 minutes TEST 1 510 MIN PRIORIT MANUELLE Le mode manuel ne fonc tionne que la nuit parce que la lumi re du jour remet le capteur en mode AUTO Mettre l interrupteur hors Re circuit pendant une seconde Pendant rout seconde plus en circuit pour alterner puis entre les modes AUTO et MANUEL Le mode manuel ne fonction S ne que lorsque l interrupteur ON TIME est aux positions A nouveau 1 5 ou 10 en circuit rupteur Certains codes de b timent locaux peu vent exiger que l installation soit faite par un lectricien qualifi 2013 HeathCo LLC 17 204028 02 F R sum du mode de commutation Placer l interrupteur ON TIME a 1 5 ou 10 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre e
4. yen Requirements Heath Zenith e The light control requires 120 volts AC e Ifyou wantto use Manual Mode the control must be wired through a switch e Some electrical codes require installa Motion Sensing Coach Lights tion by a qualified electrician Models OPERATION 1 On Time Works Day Night 7 5 Seconds x x 1 5 or 10 Min x Questions or problems Before returning To Dawn X to your retailer refer to the troubleshooting resets to Auto Mode at dawn guide in this manual or call our technical ser f vice department at 1 800 858 8501 English Note When first turned on wait about 1 2 speaking only 8 00 am to 5 00 pm CST minutes for the circuitry to calibrate Monday Friday TEST Features Set the ON TIME switch ON TIME e Light comes on when motion is detected on the bottom of the M e Automatically turns light off cover plate to TEST TEST1510 MIN e Photocell keeps the light off during daylight hours AUTO Package Contents ON TIME Set ON TIME switch to Coach Light 1 5 or 10 minutes e Easy to use Universal Mounting Bracket TEST1510 MIN e Mounting Hardware se A e Wire Connectors MANUAL MODE e Some Models Include an Optional Decora tive Tail Assembly Manual mode only works at night because daylight returns the sensor to AUTO KY Flip the light switch off for one second then back on to Picola toggle between AUTO and MANUAL MODE
5. Tuerza juntos los alambres y aseg relos con co nectores de alambre gt 0 M todo recomendado de conexi n a tierra Use un cable flexible verde de tierra no pro visto y tuerza un extremo con el cable desnudo del aparato y con el cable de a tierra de la caja Aseg relos con un conector de cables Asegure el otro extremo del cable flexible con el tornillo de a tierra de la placa de montaje IS a Blanco a blanco Negro a negro CONEXION ALTERNA Este aparato viene con un detector con una potencia de 500 Vatios Puesto que este apa rato tiene s lo una potencia de 100 vatios 400 vatios de luz adicional pueden ser contro lados por este detector Cuando desee determinar la clasificaci n de un aparato no vea tan s lo la potencia de la l mpara Mire la indicaci n que especifique el voltaje m ximo de la l mpara que el aparato puede aceptar Una vez que ha escogido los aparatos que se conectar n y ha determinado sus m ximas potencias s melas Por ejemplo si tiene 3 aparatos de 100 150 y 75 Vatios respectiva mente usted tendr un total de 325 Vatios Esquema el ctrico 1 Cuando prepare una conexi n para controlar un aparato de luz est ndar Pele el alambre rojo del detector de movimiento y con ctelo al alambre negro de la luz est ndar Conecte todos los alambres blancos La capacidad total no debe exceder los 500 Vatios 4 1 A
6. Esquema el ctrico 2 Cuando prepare una conexi n para controlar otro aparato de luz detector de movimiento Pele el alambre rojo en ambos aparatos de luz Conecte el alambre rojo del aparato controlador maestro a los alambres rojo y negro del aparato controlado esclavo Conecte todos los alambres blancos La capacidad total no debe exceder los 500 Vatios 4 1 A Esquema el ctrico 3 Cuando haga el cableado para que cualquier luz de movimiento prenda las dos luces que detectan movimiento Maestro Maestro Pele el conductor rojo de ambos aparatos de luz Conecte el conductor rojo de un aparato al conductor rojo del otro aparato Nota en la mayor a de las instalaciones se deber instalar un conductor adicional del mismo calibre que el conductor de la casa dentro de la casa para conectar los dos aparatos como maestro maestro Conecte entre si todos los alambres blancos y todos los alambres negros La potencia nominal total del aparato no debe ser m s de 500 vatios 4 1 Amp Est ndar Maestra Esclava Blanco Blanco Aparato Aparato Aparato Rojo Aparato de Luz de Luz de Luz de Luz Rojo q Negro d Negro Verde o Verde o D d Desnudo eee Diagrama de Cableado 1 Diagrama de Cableado 2 Maestra Maestra Blanco Rojo Aparato Aparato de Luz de Luz Negro j Verde o Desnudo Diagrama de Cableado 3 12 204028 02 COMPLETE LA INSTALACION 1 Meta los cables en la caja de empalm
7. Mas ter Slave Strip the red wire in both light fixtures Connect the red wire of the controlling master fixture to the red and black wires of the controlled slave fixture Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 1 A Wiring Diagram 3 When wiring so either motion light turns on both motion lights Master Master Strip the red wire in both light fixtures Connect the red wire of one fixture to the red wire of the second fixture Note In most installations an additional wire same gauge as existing house wire will have to be installed in the house to connect the two fixtures as master master Connect all white wires together and all black wires together Total fixture ratings must not exceed 500 Watts 4 1 A Standard Master Slave White White Light Light Light Y Red Light Fixture Fixture Fixture Fixture Black g Black Green Green or Bare or Bare Wiring Diagram 1 Wiring Diagram 2 Master Master White Red Light Light Fixture Fixture Black f Green or Bare Wiring Diagram 3 4 204028 02 COMPLETE THE INSTALLATION 1 Stuff the wires into the junction box Make 4162 Top Assembly sure the wires from the fixture go through the wire path and no wires get pinched Larger piece on top q Optional Assembly 5 If so equipped you may install the decorative Slide the fixture onto the Junct
8. Mauvais c blage s ils agit d une nouvelle installation Mauvaise orientation R orien ter le d tecteur pour obtenir la couverture d sir e La lampe ne i s allume pas La commande d clairage est install e dans un endroit relati vement sombre La commande d clairage est en mode essai Placer l inter rupteur ON TIME 1 5 ou 10 minutes La lampe s allume le jour La commande d clairage peut d tecter de petits animaux des arbres agit s par le vent ou la circulation automobile R orien ter le d tecteur Le r glage de port e est trop lev R duisez la port e La lampe s allume sans raison apparente 204028 02 Le d tecteur de la commande d clairage pointe vers une source de chaleur comme un vent d a ration un vent de s cheuse ou une surface peinte de couleur vive r fl chissant la chaleur R orienter le d tecteur Lacommande d clairage est en mode Manuel faites la passer au mode Auto Le r glage de port e est trop lev R duisez la port e La lampe reste A allum es conti nuellement La lampe cli gnote La chaleur qui est r fl chie par d autres objets peut affecter la commande d clairage R o rienter le d tecteur La commande d clairage est enmodeessaietse r chauffe Le clignotement est normal dans ces deux cas SERVICE TECHNIQUE Veuillez faire le 1 800 858 8501 service en anglais
9. Noir 8 Noir Vert ou Vert ou d nud d nud a Diagramme de c blage 1 debi Diagramme de c blage 2 Ma tre Ma tre Blanc Rouge Luminaire Luminaire Noir Vert ou d nud Diagramme de c blage 3 20 204028 02 COMPLETEZ L INSTALLATION 1 S assurer que les fils du luminaire suivent le passage des fils et qu aucun d eux ne soit pinc Glissez le luminaire sur les vis de montage et resserrez les vis D LE Bo te de jonction 2 Calfeutrer la surface de montage du lu minaire avec un scellant silicone r sistant aux intemp ries 3 Installer une ampoule de 100 watts max 4 Installer l ensemble sup rieur s il y a lieu Fixer l ensemble avec des vis d coratives 5 Sivousn installez pas l ensemble de queue d corative optionnel installez l crou d coratif au bas du luminaire maintenant S ES 204028 02 Ensemble sup rieur 4162 Plus grande pi ce sur le dessus Ensemble facultatif S il y a lieu installer la queue d corative comme illustr ci dessous crou hexagonal 1 Visser la tige de rallonge 2 Ajouter la queue et l l ment d coratif La pi ce d corative inf rieure comporte 3 Installer l crou d coratif un orifice de drainage 21 ESSAIS 1 Mettre en circuit le disjoncteur et l in terrupteur d clairage Le capteur doit se
10. au del des but es Rotation du capteur pour modifier la zone de couverture 4 R glerla sensibilit SENSITIVITY selon les besoins Une trop grande sensibilit pourrait causer des d clenchements in tempestifs R glez votre go t le TEMPS de fonc tionnement du luminaire apr s d tection du mouvement 1 5 ou 10 minutes 204028 02 5 FICHE TECHNIQUE Port e Jusqu 9 1 m varie selon la temp rature environnante Angle de d tection Jusqu 150 Charge lectrique Jusqu 100 W maxi mum Tungst ne incandescence Jusqu 500W 4 1 A maximum Tungst ne incandescence Mass 120 V c a 60 Hz Capacit du capteur Courant requis Modes de fonctionnement Essai automatique et priorit manuelle Minuterie 1 5 ou 10 minutes HeathCo LLC se r serve le doit d abandonner tout produit et d en changerles sp cifications en tout temps et sans contracter quelque obligation que ce soit quant l incorporation de nouvelles caract ristiques aux produits d j vendus GUIDE DE D PANNAGE SYMPT ME CAUSE POSSIBLE SYMPT ME CAUSE POSSIBLE Linterrupteur d clairage est en position hors circuit 2 Lampoule au quartz est desser r e ou grill e Le fusible du circuit a saut ou le disjoncteur est en position hors circuit La fonction de mise hors circuit la lumi re du jour est engag e Rev rifier quand il fait nuit
11. derecha superior Nota El agujero de paso del alambre en la placa de mon taje debe estar ubicado como se muestra abajo para que los alambres de la parte de atr s del aparato puedan pasar 204028 02 5 Reinstale los tornillos de montaje del aparato y fije la placa de montaje a la caja de empalme como se muestra Paso del alambre Paso del alambre Tornillo de Or ete 0 Jh SZANS a Tornillos del aparato A O O E O Placa volteada y girada CABLEADO Nota Todo el cableado debe realizarse de acuerdo con el C digo El ctrico Nacional usando tuberia 6 alg n otro medio acepta ble Pongase en contacto con un electri cista calificado si tiene alguna pregunta referente a la aptitud del sistema Como se enviaron cunano NO conecte el cable ROJO excepto que desee controlar otras luces desde el detector de movimiento f Negro Aparato Verde o de Luz Desnudo Blanco Luz de un movimiento 204028 02 Blanco Aparato Aparato de Luz de Luz Negro f Verde o Desnudo Luz de dos movimientos Tuerza los cables de la caja de empalme con los cables del aparato como se muestra abajo Aseg relos con conectores de cables Si tiene una caja de empalme de metal no necesita el cable flexible Sino esta seguro del m todo de conexi n a tierra consulte con el c digo local de construcci n Conecte los alambres del aparato a los alambres de la caja de empalme
12. di rectly towards it and more sensitive to across motion a a Motion Motion Sensor Least Sensitive Most Sensitive 3 Walk through the coverage area noting where you are when the lights turn on Move the sensor head left or right to change the coverage area Note Grasp the sensor only as shown and turn the entire sensor Any other method may damage the sensor Do not force it past the stops Rotating Sensor Head to Change Coverage Area 4 Set the SENSITIVITY as needed Too much sensitivity may increase false triggering 5 Set the amount of TIME you want the light to stay on after motion is detected 1 5 or 10 minutes 204028 02 SPECIFICATIONS Range Up to 30 ft 9 1 m varies with surrounding temperature Sensing Angle Up to 150 Electrical Load Up to 100 Watt Maximum Tungsten Incandescent Sensor Capacity Up to 500 Watt 4 1 A Maximum Tungsten Incandescent Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes HeathCo LLC reserves the right to discon tinue products and to change specifications at any time without incurring any obligation to incorporate new features in products pre viously sold TROUBLESHOOTING GUIDE POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE SYMPTOM Light will not 1 Light switch is turned off come on 2 Bulb is loose or burned out 3 Fuseis blown or circuit brea
13. du produit ou d un ou l autre de ses composants fournis invalidera totalement la pr sente garantie Cette garantie n inclut pas le remboursement pour le d rangement l installation le r glage la perte d utilisation le service non autoris ou les frais d exp dition pour le renvoi de la marchandise La garantie ne couvre que les produits assembl s HeathCo LLC et ne s tend pas aux autres quipements et composants que le client pourrait utiliser conjointement avec nos produits CETTE GARANTIE TIENT EXPRESS MENT LIEU DE TOUTES AUTRES GARANTIES EX PLICITES OU IMPLICITES Y COMPRIS DE TOUTE GARANTIE DE REPRESENTATION OU DE CONDITION DE CONVENANCE LA COMMERCIALISATION OU L EFFET QUE LES PRODUITS CONVIENNENT UN BUT OU UNE UTILISATION PARTICULI RE ET SP CIFI QUEMENT DE TOUS DOMMAGES SP CIAUX DIRECTS INDIRECTS OU SECONDAIRES LE REMPLACEMENT OU LA REPARATION CONSTITUENT LE SEUL RECOURS DU CLIENT ET HEATHCO LLC NE POURRA ETRE TENUE RESPONSABLE DE TOUS DOMMAGES SPE CIAUX DIRECTS INDIRECTS OU SECONDAIRES Y COMPRIS SANS S Y LIMITER LES PERTES COMMERCIALES ET PERTES DE PROFIT QU ELLES SOIENT PREVISIBLES OU NON Certaines provinces n autorisent pas l exclusion ou la limitation des dommages indirects ou secondaires et la limitation ou l exclusion ci dessus pourrait ne pas s appliquer vous Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos demandes li es la garantie 24
14. requiere para cualquier solicitud de garant a GARANTIA LIMITADA A 2 ANOS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 2 a os desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin cargo para Ud No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por HeathCo LLC y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A EST EXPRESAMENTE EN LUGAR DEOTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACI N O CON DICI N DE COMERCIABILIDAD O QUE LOS PRODUCTOS SE ADAPTEN PARA CUALQUIER PROP SITO O USO EN PARTICULAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N
15. 204028 02
16. 9 1 m var a con la temperatura del medio ambiente Hasta 150 Hasta un m ximo de 100 Vatios de tungs teno incandescente Hasta un m ximo de 500 Vatios 4 1 A de tungsteno incandes cente Requisitos de Energ a 120 VCA 60 Hz Fases de Operaci n PRUEBA AUTO MATICO y MODO MANUAL Retardo de Tiempo 1 5 10 minutos HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar espe cificaciones a cualquier momento sin incurrir en ninguna obligaci n de tener que incorpo rar nuevas caracter sticas en los productos vendidos con anterioridad GUIA DE INVESTIGACION DE AVERIAS La luz no se encien de El interruptor de luz est apagado El faro est flojo o fundido El fusible est quemado o el cor tacircuitos est apagado La desconexi n de luz del d a est en efecto Compru belo al anochecer Alambrado incorrecto si sta es una nueva instalaci n Apunte de nuevo el detector para cubrir las reas deseadas La luz se prende durante el d a 204028 02 El control de luz puede estar ins talado en un lugar relativamente oscuro El control de luz est en fase de Prueba Fije el interruptor del con trol a la posici n de TIEMPO 15 SINTOMA POSIBLE CAUSA La luz se El control de luz puede estar prende sin detectando animales peque os o ninguna el tr sito de autom viles Reposi raz n apa cione el detector rente La Sensi
17. 90045 Bowling Green KY 42102 9045 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product Please keep your dated sales receipt it is required for all warranty requests TWO YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of two years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only HeathCo LLC assembled products and is not extended to other equip ment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR A
18. NY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUEN TIAL DAMAGES REPAIROR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Please keep your dated sales receipt it is required for all warranty requests 8 204028 02 FUNCIONAMIENTO Modalidad Prueba Autom Manual Heath Zenith Lamparas tipo cochero con detector de movimiento A tiempo Trabaja D a Noche 5 segundas X X 1 50 10 min x Hasta el X amanecer Se pone en Autom tico al amanecer Nota Cuandolo prenda por primera vez es Modelos pere 1 2 minutos para que el circuito 4160 se calibre 4170 PRUEBA Preguntas o problemas Antes de Ponga el interruptor de ON TIME devolver el producto al minorista lea la gu a tiempo ON TIME al fondo de an lisis de aver as en este manualollame del detector en la posici n a nuestro departamento de servicio t cnico de prueba TEST TEST 1 5 10 al 1 800 858 8501 s lo se habla ingl s de 8 00 am a 5 00 pm H
19. O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILIDAD POR PARTE DE HEATHCO LLC POR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUALQUIER P RDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garant a 16 204028 02 Heath Zenith Lanterne a d tecteur de mouvement Mod les 4150 4160 4170 Des questions ou probl mes Avant de vous rendre chezle d taillant consultez la section D pannage de ce guide ou communiquez avec le service technique au 1 800 858 8501 en anglais seulement du lundi au vendredi entre 8 h 00 et 17 h 00 HNC Caract ristiques Allume l clairage lorsqu un mouvement est d tect teint automatiquement l clairage Photocellule qui maintient l clairage teint pendant la p riode de lumi re du jour Contenu de l emballage Lanterne de carrosse Console de montage universelle facile utiliser Ferrures de montage Serre fils Certains mod les comprennent un ensem ble facultatif de queue d corative Exigences La commande d clairage n cessite une alimentation 120 volts c a Si vous d sirez utiliser la priorit manuelle
20. bilidad es demasiado alta Reduzca la sensibilidad La luz se queda prendida continua mente El control de luz est apuntando hacia una fuente de calor tal como un conducto de aire de secadora o hacia una superficie con pintura brillante y que refleja el calor Reposicione el detector El control de luz est en fase Manual C mbiela a Auto La Sensibilidad es demasiado alta Reduzca la sensibilidad La luz se prende y se apaga El calor que se refleja de otros objetos pueden estar afectando al detector Reposicione el detector El control de luz est en fase de Prueba y calent ndose El prenderse y apagarse es normal bajo estas condiciones Apague el Aumento SERVICIO TECNICO Favor de llamar al 1 800 858 8501 s lo para hablar en ingl s para pedir ayuda antes de devolver el producto a la tienda Si tiene alg n problema siga esta gu a Usted puede tambi n visitar nuestro sitio Web www hzsupport com Si el problema contin a llame al 1 800 858 8501 s lo para ha blar en ingl s de 8 00 AM a 5 00 PM CST L V Usted puede tambi n escribir a HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Servicio T cnic Si se llama al Servicio T cnico por favor tener lista la siguiente informaci n N mero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto Por favor guarde su recibo de venta fechado se lo
21. building code Connect the fixture wires to the wires in the junction box Twist the wires together and secure with wire connectors E Recommended Grounding Method Use a green ground pigtail not provided and twist one end together with the bare fixture wire and the box ground wire Secure with a wire connector Secure the other end of the pigtail with the GND screw on the mounting plate White to white Black to black OPTIONAL WIRING This fixture is provided with a sensor rated for 500 Watts Since the fixture is only rated 100 Watts 400 Watts of additional lighting may be controlled by this sensor When determining what a fixture is rated for do not simply look at the rating on the lamp in the fixture Look at the marking which specifies the maximum lamp wattage for which the fixture is suitable Once you have selected the fixtures to be connected and determined their maximum ratings add these ratings up For instance if you have 3 fixtures rated 100 Watts 150 Watts and 75 Watts respectively you have a total load of 325 Watts Wiring Diagram 1 When wiring to control a standard light fixture Strip the motion sensor s red wire and connect to the standard light s black wire Connect all white wires together Total fixture ratings must not exceed 500 Watts 4 1 A Wiring Diagram 2 When wiring to control another motion sensing light fixture
22. e Ensamble superior del Asegurese que los cables del aparato modelo 4162 pasen por el paso para los cables y que no est n pinchados La pieza mas grande debe estar arriba Montaje Opcional Si lo tiene usted puede instalar la cola de corativa como se muestra abajo Deslice al apartato sobre los tornillos de montaje y ajuste las tuercas Tuerca hexagonal 1 Atornille la 2 Calafatee el aparato y la superficie de erie Aa tuerca ae a montaje con un sellador de silicona contra aoe rO la intemperie 3 Ponga una bombilla de 100 Vatios Max gt 2 3 Ponga la tuerca 4 Sielaparatolotiene instale la parte de arri ae ae ba Aseg rela con tornillos decorativos La pieza inferior e f de adorno tiene un 5 Si no va a instalar el conjunto del cabo agujero de desag e opcional ponga ahora latuerca decorativa en la parte de abajo del aparato 204028 02 13 PRUEBA Prenda el cortacircuitos y el interrup tor de luz 1 Nota Eldetectortieneun per odo de cerca de 1 minutos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 1 2 minutos 2 Fije el interruptor SENSITIVITY a la posici n media y el de ON TIME a la posici n de TEST TEST 1 5 10 MIN ON TIME LO M HI SENSITIVITY Evite apuntar el control hacia
23. e comme indiqu ci dessous Utilisez des serre fils Si la bo te de jonction est en m tal vous pourriez n ces siter une queue de cochon verte Si vous avez des doutes sur la m thode de mise la terre consultez votre code du b timent Branchez les fils du luminaire aux fils dans la bo te de raccordement Torsadez ces fils ensemble puis ajoutez y un connecteur de fils EN M thode de mise la terre recommand e Utilisez une queue de cochon verte non fournie ettorsadez en une extr mit avec le fil nu du luminaire et le fil de terre de la bo te de jonction Utilisez un serre fils Fixez l autre extr mit de la queue de cochon avec la vis de terre GND sur la plaque de montage Blanc a blanc Noir a noir CABLAGE FACULTATIF Ce luminaire est pourvu d un capteur de 500 W Comme ce luminaire ne consomme que 100 W le capteur peut commander 400 W d clairage suppl mentaire Lorsque vous d terminez l intensit que peut supporter un luminaire ne vous contentez pas de simplement lire l intensit indiqu e sur l ampoule Recherchez l tiquette indiquant le wattage d ampoule maximal de l appareil Une fois que vous avez choisi les luminaires raccorder et d termin leur intensit maximale respective additionnez les intensit s Par exemple si vous avex 3 appareils dont l intensit est 100 Watts 150 Watts et 75 Watts respectivement
24. en fase AUTO MATICA INSTALACION Tiempo estimado de instalaci n 30 minutos Art culos que se necesitan para la instalaci n no incluidos e Tornillos Phillips y de cabeza plana e Alicates e Desforrador cortador de alambre e Lentes de seguridad e Bombilla e Calafateo de silicona Para un mejor funcionamiento instale el aparato a casi 1 8 m del suelo ADVERTENCIA Desconecte la ener gia en el disyuntor 1 Quite las 2 Quite la placa de montaje dos tuerca p gt SN 3 Ajuste los tornillos tan s lo con los dedos Paso del alambre XS Se Al S NES Z 4 Atornille la placa de montaje a la caja de empalme Tornillos del aparato Este aparato viene con un soporte de mon taje universal Est pre ensamblado en el aparato para acomodarse a la mayor a de las aplicaciones de cajas de empalme Sin embargo si las ranuras de la placa de montaje no se alinean con los agujeros del tornillo de la caja de empalme 1 Quite de la placa de montaje los tornillos de montaje del aparato Nota No quite el tornillo de a tierra 2 Fije el cable flexible al tornillo de a tie rra de la placa de montaje Vea M todo recomendado de conexi n a tierra para m s informaci n 3 Voltee la placa de montaje 4 Voltee la placa de montaje de modo que el agujero de paso del alambre est en la parte
25. ion tail as shown below mounting screws and Box tighten nuts gt _ Hex nut cas 2 Caulk fixture mounting surface with silicone weather sealant 1 Screw in 3 Install one 100 Watt maximum light bulb extension bar 2 ue piece r 5 i ana trim 4 Ifso equipped install the fixture top Secure s with decorative screws gt 3 Install 5 If you will not be installing the optional tail Bottom trim piece decorative nut assembly install the decorative nut onto has drain hole the bottom of the fixture now S 204028 02 5 TESTING 1 Turn on the circuit breaker and light switch Note Sensorhas a 1 minute warm up pe riod before it will detect motion When first turned on wait 1 2 minutes 2 Set SENSITIVITY to mid position and ON TIME to TEST position TEST 1 5 10 MIN ON TIME LO M HI SENSITIVITY Avoid aiming the control at Pools of water or objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting daylight may trigger the shut off feature Do not point other lights at the sensor lt gt 150 6 ft 1 8 m 30 ft 9 1m Maximum Range Maximum Coverage Angle The detector is less sensitive to motion
26. ker is turned off Daylight turn off is in effect recheck after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover desired area Lightcomes on in daylight Light control may be installed in a relatively dark location Light control is in Test Set control switch to an ON TIME position Lightcomes on for no apparent reason Light control may be sensing small animals or automobile traffic re aim sensor Sensitivity is set too high Reduce sensitivity 204028 02 Light stays on continuously 1 The sensor is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Re aim sensor Lightcontrolisin Manual Mode Switch to Auto Sensitivity is set too high Reduce sensitivity Light flashes on and off Heat being reflected from other objects may be affecting the sensor Re aim sensor Light control is in the Test mode and warming up flashing is normal under these conditions TECHNICAL SERVICE Please call 1 800 858 8501 English speaking only for assistance before returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www hzsupport com Ifthe problem persists call for assistance at 1 800 858 8501 English speaking only 8 00 AM to 5 00 PM CST M F You may also write to HeathCo LLC P O Box
27. l to ground screw on mounting plate See Recommended Grounding Method for additional information 3 Flip the mounting plate over 4 Rotatethe mounting plate so the wire path is on the upper right Note The wire path on the mounting plate must be located as shown below to allow the wires on the back of the fixture to pass through 5 Reinstall the fixture mounting screws and attach the mounting plate to the junction box as shown Wire Path Wire Path Ground Screw Tr DO gt eve ES A Ground Screw 4 Attach mounting plate to junction box lt NZ es O O Fixture Screws As Shipped Flipped and Rotated 204028 02 WIRING Note All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means Contact a qualified electrician if there is any question as to the suitability of the system A CAUTION DO NOT connect the RED wire unless you want to control other lights from the motion sensor Black f Light Fixture Green or Bare White One Motion Light White Light Light Fixture Fixture Black f Green or Bare Two Motion Lights 204028 02 Twist the junction box wires and the fixture wires together as shown below Secure with wire connectors If you have a metal junction box you may not need the green pigtail If you are unsure about the grounding method consult your local
28. la charge totale est 325 Watts Diagramme de c blage 1 Cablage d un luminaire standard d nudez le fil rouge du d tecteur de mouvement et raccordez le au fil noir du luminaire standard Raccordez tous les fils blancs ensemble L intensit maximale ne noit pas d passer 500 Watts 4 1 A Diagramme de c blage 2 Cablage d un autre luminaire d tecteur de mouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de commande ma tre aux fils rouge et noir du luminaire command satellite Branchez tous les fils blancs ensemble La consommation totale des luminaires ne doit pas tre sup rieure 500 Watts 4 1 A Diagramme de c blage 3 C blage de sorte que l une ou l autre des commandes d clenche les deux luminaires Maitre Maitre d nudez le fil rouge des deux luminaires Branchez le fil rouge d un luminaire au fil rouge du second luminaire Note Dans la plupart des cas un fil suppl mentaire de m me calibre que le fil de la r sidence doit tre install pour raccorder les deux luminaires en configuration principal principal Raccordez tous les fils blancs ensemble puis faites de m me avec tous les fils noirs La consommation totale des luminaires ne doit pas tre sup rieure a 500 Watts 4 1 A Standard Maitre Satellite Blanc Blanc Rouge Luminaire Luminaire Luminaire Luminaire Rouge
29. n circuit PRIORIT MANUELLE Si vous ne savez plus dans quel mode se trouve l appareil couper l alimentation pendant une minute puis la r tablir Apr s le temps d talonnage la commande reviendra au mode AUTO INSTALLATION Temps estimatif d installation 30 minutes Articles n cessaires l installation non fournis e Tournevis lame droite et cruciforme Phillips e Pinces e Pinces d nuder ou couper e Lunettes de protection e Lampe lectrique e Produit de calfeutrage base de silicone Pour un rendement optimal montez le lumi naire environ 1 8 m au dessus du sol MISE EN GARDE Coupez l alimentation au disjoncteur ou au fusible 1 Enlever les deux crous 2 Enlever la plaque de montage 3 Resserrez les vis avec les doigts Passage des fils y ON Vis de la boite de jonction 4 Fixer la plaque de montage a la boite de jonction Ce luminaire vous est fourni avec un support universel d ja fix au luminaire ce support convient a la majorit des boites de raccor dement lectrique Toutefois si les rainures de la plaque de montage ne correspondent pas aux trous des vis de la boite 1 Retirez les vis de fixation au luminaire de la plaque de montage Note Ne retirez pas la vis de mise a la terre 2 Fixez la rallonge du fil de terre la vise de mise a la terre de la plaq
30. ora Est ndar del Centro AUTOMATICO de Lunes a Viernes Ponga elinterruptordetiem ON TIME Caracter sticas po ON TIME enla posici n db y de 1 50 10 minutos TEST 1 5 10 La luz se prende cuando se detecta movi miento Apaga la luz automaticamente La fotoc lula mantiene la luz apagada durante las horas del dia Contenidos del Paquete Luz de Coche Soporte universal de facil uso Ferreteria de montaje Conectores de alambre Algunos modelos incluyen un conjunto opcional para extension decorativa Requisitos El control de luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor Algunos c digos requieren instalaci n por un electricista calificado O 2013 HeathCo LLC MODO MANUAL El modo manual funciona s lo por la noche porque la luz del d a pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vu lvalo a prender El modo manual funciona s lo cuando el interruptor de tiempo ON TIME est en la posici n de 1 50 10 minutos 1 segundo APAGADO luego pr ndalo 204028 02 S Resumen de las modalidades del interruptor Mueva el interruptor de tiempo ON TIME a 1 5 o 10 minutos Apague el interruptor por un segundo y pr ndalo de nuevo MODO MANUAL Si se confunde mientras cambia de fases apague la electricidad por un minuto y pr ndala de nuevo Despu s del tiempo de calibraci n el control estar
31. r chauffer 1 1 2 minute avant de pouvoir d tecter le mou vement Lorsque l appareil est mis en circuit attendre 1 minute Note Placez le commutateur SENSITIVITY en position m diane et le commutateur ON TIME TEST TEST 1 5 10 MIN ON TIME LO M HI SENSITIVITY viter de pointer l appareil Surdes flaques d eau ou des objets dont la temp rature change rapidement Ces sources peuvent causer des d clenche ments intempestifs e Vers des zones o des animaux ou la circulation risquent de d clencher l ap pareil e Sur des objets avoisinants de grande dimension et de couleur claire La r flexion pourrait d clencher la fonction de mise hors circuit la lumi re du jour Ne pas pointer d autres sources lumineuses sur la commande d clairage E 150 1 8 m 91m Port e maximale Angle de couverture maximale 22 Le d tecteur est moins sensible au mouve ment dans sa direction Az Mouvement Mouvement ASS D tecteur Le moins sensible Le plus sensible 3 Marcher dans la zone de couverture et noter quel endroit l clairage se d clen che D placer la t te du d tecteur vers la gauche le droit ou le c t pour modifier la zone de couverture Note Saisir le d tecteur seulement de la fa on indiqu e et tourner tout l ensemble Toute autre fa on de faire pourrait endommager le d tecteur Ne pas le forcer
32. seulement pour obtenir de l aide avant de retourner l article au magasin En cas de probl me suivez ce guide Vous pouvez aussi visiter notre site Web www hzsupport com Si le probl me persiste composez le 1 800 858 8501 service en an glais seulement entre 8 h 00 et 17 h 00 HNC du lundi au vendredi Vous pouvez aussi crire au HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants port e de main num ro du mod le date d achat et endroit de l achat Aucune pi ce de rechange n est disponible pour ce produit Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos de mandes li es la garantie GARANTIE LIMIT E DE 2 ANS Il s agit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits variables d une province l autre Pendant une p riode de 2 ans compter de la date d achat toute anomalie de fonctionnement imputable un vice de mat riau ou de main d oeuvre sera corrig e gratuitement Exclusions de la garantie R parations r glage et calibrage dus une mauvaise utilisation un mauvais traitement ou la n gligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autoris ou la modification
33. ue de montage consultez la section M thode de mise la terre recommand e pour plus de d tails 3 Retournez la plaque de montage 4 Faites tourner la plaque de montage de sorte que l orifice de passage des fils se trouve dans le coin sup rieur droit Note Lorifice de passage des fils de la plaque de montage doit tre plac comme illustr ci dessous pour permettre le passage des fils l arri re du luminaire 204028 02 al Remettez en place les vis de fixation au luminaire et la vis de mise la terre puis fixez la plaque de montage la bo te de raccordement comme illustr Passage des fils Passage des fils CD Vis de fixation au luminaire Tel qu exp di Plaque retourn e apr s rotation C BLAGE Note Tous les fils doivent tre install s dans un conduit ou un autre dispositif acceptable conform ment au Code national de l lectricit Contactez un lectricien qualifi pour toute question relative la pertinence de l installation AVERTISSEMENT NE PAS raccorder le fil ROUGE moins que vous ne vouliez commander d autres luminaires au moyen du d tecteur de mouvement Noir Vert ou d nud Blanc Une lanterne d tecteur de mouvement 204028 02 Blanc Luminaire Luminaire Noir Vert ou d nud Deux lanternes d tecteur de mouvement Torsadez ensemble les fils de la bo te de jonction et ceux du luminair