Home

Transformer Manual 120W Update_20052014

image

Contents

1. a m v j U MM i N l Z TRANSFORMER e 120 WAIT LANDSCAPE LIGHTING TRANSFORMER MODEL NO TRF101120 C 120 WATT 12V AC LANDSCAPE LIGHTING TRANSFORMER FOR USE ON 120V CIRCUITS ONLY OUTDOOR RECEPTACLE SHOULD BE OF GFCI TYPE NOT FOR USE WITH SUBMERSIBLE FIXTURES e DO NOT use this transformer with submersible fixtures e DO NOT repair or tamper with cord or plug e DO NOT use extension cords e DO NOT submerge the transformer in water e DO NOT connect two or more transformers in parallel e DO NOT use the transformer with a dimmer switch e DO NOT install the transformer within 10 feet of a pool spa or fountain e DO NOT mount the transformer upon combustible material e DO NOT bury the connectors or cables in combustible materials such as wood chips bark dried leaves or at depth greater than 6 inches e DO NOT exceed the maximum wattage of the transformer s terminal e ONLY plug the transformer cord into a covered 120V AC Class A Type GFCI ground fault circuit interrupter receptacle with a hooded flush type cover plate marked WET LOCATION e The ambient temperature range in which this transformer will operate is from 30 C to 40 5 C The device is a certified component of a landscape lighting systems CAUTION ALWAYS DISCONNECT THE TRANSFORMER FROM THE ELECTRICAL OUTLET where the suitability of the combination shall be determined by UL or WHEN WORKING ON THE LIGHTING SYSTEM local inspection authorities h
2. e Assurez vous que le transformateur est connect en prise d alimentation e V rifiez la connexion du c ble basse tension assurez vous qu il est bien connect avec le transformateur e V rifier le c blage de la connexion de fixation Assurez vous que les broches de contact perc l isolation en plastique de fil et touche le fil lectrique l ext rieur e Contr lez l ampoule Si ampoule est cass e remplacez la par une ampoule neuve e V rifiez et assurez vous que le transformateur n est pas surcharg 3 uf 5 5 q a 9 A SHORT RUN 12VAC OUTPUT Short run SCH MA 3B PHOTOCELL SL SETTINGS 2 Hours BUTTON u 3 Hours 4 Hours 5 Hours 6 Hours 7 Hours Auto On at Dusk 8 Hours With Photo Cell UP OWN 9Hours Then Off at Dawn Yo PUSH repeatedly Auto On Off Dusk to Dawn to select from 12 Manual On FUNCTIONS OFF SCH MA 4 Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com
3. distribution of lights around the perimeter of a garden in a closed loop e Determine the distribution of lights and calculate the total length of cable that is needed to go around and SHORT RUN LOOPING return to the transformer s terminal blocks 12VAC OUTPUT 12VAC OUTPUT e Make sure not to cross the wires when routing the wires back to the terminal blocks The wire coming out from a particular terminal block must go back in the same terminal block Note the wire has a smooth side and a ridged side for easy identification e Wrong wire connection will lead to protection mode The fixtures will not light up on the short run and the fixtures will be abnormally dim on the long run Please check the circuit and re connect e Make sure that all connections are secure NOTE If you want to test the photocell during the day plug the transformer into 120V covered GFCI outlet and use a black plastic cover to cover the photocell make sure the photo cell does not receive any light Press the setting button to A make sure the photocell is completely turn ON and completely covered by the plastic cover Remove the black plastic cover and your lighting fixtures will be shut off automatically DIAGRAM 3B OPERATING THE LIGHTING SYSTEM After installing the transformer check carefully and turn on the electrical source Select the working mode you like ON Light stay on AUTO Photocell There are double key press for your operation Every time
4. luminaires aussi uniform ment que possible le long du c ble 2 Placez les appareils de puissance sup rieure plus pr s du transformateur et les appareils de puissance inf rieure plus loin du transformateur 3 Placez le premier appareil loigner d un minimum de 10 pieds du transformateur 4 Une autre m thode de connexion par c ble appel Looping doit tre utilis pour maintenir la production uniforme de la lumi re Low Voltage Cable INSTALLATION DU C BLE SCH MA 3 1 Desserrez les vis du port de c ble au fond du transformateur 2 Enfilez les c bles pr d nud s dans les ports de c ble au fond du transformateur et poussez fermement Serrez les vis 3 Compl tez la disposition et tester le syst me avant d enterrer le c ble 4 Montez le transformateur au mur l aide des vis et du mod le indiqu s dans les instructions de montage SCH MA 3 Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com a i J Luminiz TRANSFORMATEUR 120 WATT D ECLAIRAGE INSTALLATION DU C BLE BOUCLER VOIR SCH MA 3B Cette m thode est particuli rement bonne pour la distribution des lumi res autour du p rim tre d un jardin dans une boucle ferm e e D terminez la distribution des lumi res et calculer la longueur de c ble Tatal qui est n cessaire pour faire le tour et revenir aux borniers du transformateur e Assurez vou
5. Ne pas fixer le transformateur au mur a ce moment Tout d abord connectez le c ble a basse tension aux bornes du transformateur CONNECTER CORDON D ALIMENTATION A BASSE TENSION AU TRANSFORMATEUR e Pour la connexion de c ble 12 16 diviser une extr mit du c ble d environ 2 et enl ve d environ 3 4 17 19mm d isolant de chaque fil et doucement torsadez ensemble les brins Voir sch ma 2 e La distance de c ble la puissance totale et l espacement des appareils affectent la puissance lumineuse de chaque appareil le long de la course e Un c ble de calibre sup rieur comme de calibre 12 recommand pour tous courses permet des appareils de puissance sup rieure au d but de la course e Veillez toujours utiliser le c ble requis pour la charge de puissance m me sur de petites s ries S il vous pla t se r f rer aux configurations d installation recommand e sur la table ci dessous Ne jamais d passer 120W pour une course SCHEMA 2 S il vous pla t assurez de serrer la vis de la connexion de sortie au fil pour viter un court circuit et surchauff e REMARQUE Utilisation du c ble de calibre correct est essentiel pour ATTENTION UN INCENDIE EST POSSIBLE SI UN FIL EST LASSE SERREZ BIEN LES VIS DE obtenir un bon rendement de l clairage Pour l usage avec SPT 3 CONNEXION SPT 2W souterrain bas circuit d nergie c ble de type ext rieur Longueur 25 minimum CONSEILS ADDITIONELS 1 Distribuez les
6. aving jurisdiction CALCULATION LIGHTING CAPACITY The 120W transformer has 120W circuits which powers up to 120W of light To determine the maximum number of fixtures that can be safely connected to this transformer add up the individual wattages of all the fixtures The total wattage of your fixtures must not exceed output capacity of the 120W transformer ASSEMBLY INSTRUCTION 1 1 Select location near 120V AC covered outlet with cover plate marked for WET LOCATION 2 Drill holes 3 16 in 4 76mm 3 Install anchors C and screws D leaving enough space for the transformer to hang on the screws by means located on the back of the Transformer NOTE Do not attach the transformer to the wall at this time First connect the low voltage cable to the transformer terminals CONNECT LOW VOLTAGE CABLE TO TRANSFORMER e For cable connection 12 16 split one end of cable approximately 2 and strip about 3 4 17 19mm of insulation off each wire and twist strands tightly See Diagram 2 Cable distance total wattage and spacing of fixtures affect the light output of each fixture along the run Higher gauge cable such as 12 gauge recommended for all runs allows for the higher wattage fixtures at the beginning of the run e Always make sure to use the cable required for the wattage load even on short runs Please refer to the recommended installation configurations on below table Never exceed 120W for any run DIAGRAM 2 Please
7. make sure to tighten the screw of the output connection with wire to prevent short circuit and overheat CAUTION FIRE IS POSSIBLE BY A LOOSE WIRE TIGHTEN CONNECTION SCREWS NOTE Using the correct gauge cable is essential for obtaining proper FIRMLY lighting performance For use with SPT 3 SPT 2W underground low energy circuit outdoor type cable Minimum 25 length ADDITIONAL TIPS 1 Distribute the light fixtures as evenly as possible along the cable 2 Position the higher wattage fixtures closer to the transformer and lower wattage fixture away from it 3 Place the first fixture a minimum of 10ft away the transformer 4 Another cable connection method called Looping should be used to maintain even light output Low Voltage Cable CABLE INSTALLATION DIAGRAM 3 1 Loosen the cable port screws at the bottom of the transformer 2 Thread the pre stripped cables into the cable ports in the bottom of transformer and push in firmly Tighten the screws securely 3 Complete layout and test the system before burying cable 4 Mount the transformer to the wall using screws and template shown in the assembly instructions Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON MOV 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com c v J B U MM N l TRANSFORMER e 120 WATT LANDSCAPE LIGHTING TRANSFORMER LOOPING WIRE INSTALLATION SEE DIAGRAM 3B This method is especially good for
8. ment Le transformateur restera galement sur votre r glage automatique m me si l appareil est teint il fonctionne toujours selon votre premier r glage Voir sch ma 4 S lectionnez le r glage en appuyant sur le bouton SETTING Il y a 12 modes de travail la diff rent mode de travail ont de diff rents codes Appuyez plusieurs reprises pour se d placer vers les diff rentes s lections O ON lumi res restent allum es en permanence Arr t voyants restent de fa on permanente A AUTO les lumi res s allume la tomb e de la nuit s teigne l aube Moment 1 9 Hours Eclairage au cr puscule s arr t vers le bas avec la cellule photo lectrique et puis il s teint apr s s lectionn heures IMPORTANT Si les circuits cass ou voyages il peut y avoir probl me potentiel pour un feu D branchez imm diatement le transformateur de la prise lectrique et v rifiez les points suivants e Un c ble basse tension est correctement ins r dans les orifices de c bles au bas du transformateur e Rechercher une surcharge ou un court circuit fils touche le long du c ble e V rifiez que les appareils sont correctement install s sur le c ble et qu il n y a pas de court circuit Effectuer toutes les r parations avant de faire fonctionner le syst me d clairage GUIDE DE D PANNAGE Si le transformateur ne fonctionne pas la nuit elle peut tre caus e par une des conditions suivantes
9. oltage cable connection make sure it is well connected with the transformer e Check the wiring of the fixture connector Make sure the contact pins pierced the wire plastic insulation and touch the electric wire outside Check the bulb If the bulb is broken replace with new bulb Check and make sure the transformer is not overload Designed and Imported by Luminiz Inc 27 Leading Rd Etobicoke ON M9V 4B7 Canada 416 494 6616 1 855 LUMINIZ www luminiz com c m p v Lum i NIZ TRANSFORMATEUR e 120 WATT D ECLAIRAGE NO DE MOD LE TRF101120 C 120 WATT 12V AC TRANSFORMATEUR D ECLAIRAGE POUR DES CIRCUITS DE 120 V SEULEMENT LE RECIPIENT EXT RIEUR DEVRAIT TRE DU TYPE GFCI NE PAS UTILISER AVEC DES APPAREILS SUBMERSIBLES e NE PAS utiliser ce transformateur avec des appareils submersibles e NE PAS r parer ou modifier le cordon ou la fiche e NE PAS utiliser de rallonges e NE PAS immerger le transformateur dans l eau e NE PAS connecter plusieurs transformateurs en parall le e NE PAS utiliser le transformateur avec un gradateur de lumi re e NE PAS installer le transformateur moins que 10 pieds de distance d une piscine d un spa ou d une fontaine e NE PAS monter le transformateur sur un mat riau combustible e NE PAS enterrer les connecteurs ou des c bles en mat riaux combustibles tels que des copeaux de bois l corce des feuilles s ch es ou une profondeur sup rieure 6 pouce
10. s e NE PAS d passer la puissance maximale du terminal de s du transformateur e BRANCHER le cordon du transformateur dans une prise couverte de 120V AC de type Classe A GFCI disjoncteur de d faut de la terre avec un plaque encapuchonn marqu WET LOCATION e La gamme de temp rature ambiante pour l op ration optimale du transformateur est de 30 C a 40 5 C i f Le dispositif est un composant certifi d un syst me d clairage dont la ATTENTION DEBRANCHEZ TOUJOURS LE TRANSFORMATEUR DE LA PRISE ELECTRIQUE pertinence de la combinaison doit tre d termin e par UL ou autorit s LORSQUE VOUS TRAVAILLEZ SUR LE SYST ME D CLAIRAGE de contr le locales ayant juridiction CALCULER LA CAPACIT DE LECLAIRAGE Le transformateur 120W poss de des circuits de 120W qui alimente jusqu 120W de lumi re Pour d terminer le nombre maximal d appareils pouvant tre connect s en toute s curit ce transformateur additionner les puissances individuelles de tous les appareils La puissance totale de vos appareils ne doit pas d passer la capacit de production du transformateur 120W INSTRUCTIONS D ASSEMBLAGE 1 1 Choisissez un lieu pr s de la prise couverte de 120V AC avec couvercle marqu pour WET LOCATION 2 Percez des trous de 3 16 po 4 76 mm 3 Installez les ancrages C et les vis D en laissant suffisamment d espace pour accrocher le transforma teur sur les vis de l arri re du transformateur REMARQUE
11. s de ne pas croiser les fils lors du routage des c bles vers les blocs de jonction Le fil sortant d un bloc de terminal particulier doit retourner dans ce m me bloc terminal Notez le fil a un c t lisse et un c t stri pour une identification facile e Une mauvaise connexion de fil m nera un mode de protection Les appareils ne seront pas s allumer en court terme et les appareils seront anormalement faibles en long terme S il vous plait v rifier le circuit et reconnecter e Assurez vous que toutes les connexions sont s curis es REMARQUE Si vous voulez tester la cellule pendant la journ e brancher le transformateur de 120V une prise couverte GFCI et utiliser un couvercle en plastique noir pour couvrir la cellule photo lectrique assurez vous que la cellule photo lectrique ne re oit pas de lumi re Appuyez sur le bouton de r glage A assurez vous que la cellule est compl tement allumer et enti rement recouvert par le couvercle en plastique Retirez le couvercle en plastique noir et vos appareils d clairage seront ferm s automatiquement FONCTIONNEMENT DU SYSTEME D ECLAIRAGE Apr s l installation du transformateur v rifier soigneusement et mettez la source lectrique S lectionnez le mode de travail que vous d sirez ON lumi res restent allumer AUTO photocellule Il y a deux touche appuyez pour votre op ration Chaque fois que vous appuyez sur la cl il se changera un autre mode de fonctionne
12. you press the key it will turn to another working mode The transformer will also keep your setting automatically even though the system power OFF and turn back to work it still operate according to your prior setting See Diagram 4 Select setting by pressing SETTING Button There are 12 working modes for your option difference working way have difference code Push repeatedly to move to the different selections O ON Lights stay ON continuously Auto On at Dusk _ OFF Lights stay OFF permanently Hours Wim Phot Cell AUP Woow A AUTO Lights ON at dusk off at dawn cas Ga ice PUSH repeatedly Timing 1 9 Hours Lights on at dusk off at down with photocell and then they will turn off after the eal ty occas selected hours OFF DIAGRAM 4 IMPORTANT If the circuits break or trips there may be potential problem for a fire Immediately unplug the transformer from the electrical outlet and check the following e Low voltage cable is correctly inserted in the cable ports at the bottom of the transformer e Check for overload or short circuit wires touching along the cable e Check that fixtures are correctly installed on the cable and that there are no short circuits Make all repairs before operating the lighting system TROUBLE SHOOTING If the transformer does not work at night it may be caused by one following conditions e Make sure the transformer is connected into power receptacle Check the low v

Download Pdf Manuals

image

Related Search

Related Contents

the 510 User Manual    Conrad Bluetooth® Headset PSI 2  - A.J.Pinto  Oreck AIR7 User's Manual    Canon ColorPASS-Z5000 Getting Started Guide  TrujilloSamayoaRuben  Audit qualité : contenu et mode d`emploi  Service Bulletin 167 - Royal Vendors, Inc.  

Copyright © All rights reserved.