Home

PDF, 733 KB

image

Contents

1. Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Model Smart Control is used exceeds the applicable RF compliance level above the Model Smart Control should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Model Smart Control Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 50 Table 204 Recommended separation distances between portable and mobile RF communications equipment and the Model Smart Control The Model Smart Control is intended for use in an electromagnetic environment in which radiated RF Disturbances are controlled The customer or the user ofthe Model Smart Control can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the Model Smart Control as recommended below according to the maximum output power of the communications equipment Rated maximum Separation Distance acco
2. CEX sul France 5 bis rue Maryse Basti BP15 69671 Bron Cedex India Inde B 308 Everest Grande Mahakali Caves Road Andheri East Mumbai 400 093 Netherlands Pays Bas Ir D S Tuijnmanweg 10 4131 PN VIANEN New Zealand Nouvelle Z lande 10 215 Rosedale Rd M277 Private Bag 300987 Albany Auckland Russia Russie Tverskaya Str 16 bldg 3 1st floor Moscow 125009 South Africa Afrique du Sud First Floor Selborne House Fourways Golf Park Roos Street Fourways Johannesburg Spain Espagne Avenida de la Industria n 13 15 Poligono de Canastell 03690 Sant Vicent del Raspeig Alicante Espana Sweden Su de F rmansv gen 2 4 tr SE 11743 Stockholm United Kingdom Royaume Uni St George House Cygnet Court Centre Park Warrington Cheshire WA1 1PD U S A Etats Unis Suite A 2300 Berkshire Lane North Plymouth MN 55441 Unitron Hearing Ltd 20 Beasley Drive case postale 9017 Kitchener ON N2G 4X1 Canada Distributor Distributeur www unitron com ca unitron K 10 047 029 5645 CE
3. autres appareils Toutefois lorsque vous utilisez la t l commande Smart Control pr s d un ordinateur d un appareil de communication comme un t l phone cellulaire num rique ou d un autre champ magn tique fort vous devrez peut tre vous loigner d au moins 60 centim tres pour que la t l commande fonctionne bien Si vos instruments auditifs ne r pondent pas la t l commande Smart Control cause d une perturbation inhabituelle due un champ magn tique loignez vous de celui ci 45 Identification Le num ro de s rie et l ann e de fabrication sont indiqu s l int rieur du compartiment pile Veuillez indiquer vos coordonn es sur l autocollant fourni avec votre nouvelle t l commande Smart Control et situ l int rieur du compartiment pile 46 Declaration of conformity Hereby Unitron Hearing declares that Smart Control is in compliance with the essential requirements and other relevant provisions of Directive 93 42 EEC To obtain a copy of the Declaration of Conformity please contact your local representative from the list of Unitron Hearing Distributors This device complies with part 15 of the FCC rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device does not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operati
4. hearing aids to ensure they are able to receive the Smart Control commands Smart Control is designed to be used comfortably in your hand at a maximum distance of one arm s length You do not have to point the remote at your hearing aids Placing the remote control directly next to or too close to your hearing aids may decrease the remote s effectiveness Selecting which hearing aid to adjust At the top of the remote control there is a Left Both Right switch This switch allows you to select the hearing aids you want to adjust Slide the switch to the left position to adjust your left hearing aid only The left blue indicator light will flash to indicate your left hearing aid is being adjusted Slide the switch to the right position to adjust your right hearing aid only The right red indicator light will flash to indicate your right hearing aid is being adjusted Slide the switch to the center position to adjust both your hearing aids Both indicator lights will flash to indicate your left and right hearing aids are being adjusted at once Adjusting your hearing aids with Smart Control Your Smart Control provides backlighting when it is first turned on and each time a button is pressed allowing you to see the remote buttons in dimly lit environments Scroll wheel comfort clarity setting Available with Quantum 20 and 12 Moxi 20 and 12 Passport Latitude 16 Yuu and Next 16 hearing a
5. 27 Instructions d utilisation Avant d utiliser votre t l commande Smart Control mettez vos instruments auditifs en marche pour vous assurer qu ils re oivent les commandes de la t l commande Smart Control La t l commande Smart Control a t con ue pour tenir de fa on confortable dans votre main et tre utilis e une distance maximale quivalente la longueur d un bras Il n est pas n cessaire de pointer la t l commande vers vos instruments auditifs Placer la t l commande directement c t ou trop pr s de vos instruments auditifs peut diminuer son efficacit S lection de l instrument auditif r gler Sur le dessus de la t l commande se trouve un interrupteur gauche bilat ral droit Cet interrupteur vous permet de s lectionner les instruments auditifs que vous voulez r gler 28 Faites glisser l interrupteur vers la position gauche pour r gler uniquement votre instrument auditif gauche Le voyant gauche bleu clignotera pour indiquer que vous tes en train de r gler votre instrument auditif gauche Faites glisser l interrupteur vers la position droit pour r gler uniquement votre instrument auditif droit Le voyant droit rouge clignotera pour indiquer que vous tes en train de r gler votre instrument auditif droit Faites glisser l interrupteur vers la position centrale pour r gler vos deux instruments auditifs Les deux voyants clignoteront pour indiqu
6. Smart Control remote guide Guide de la t l commande Smart Control smart control unitron Hearing matters Thank you Thank you for choosing Unitron Smart Control remote for your Unitron hearing aids At Unitron we care deeply about people with hearing loss We work closely with hearing healthcare professionals to make advanced purpose driven solutions available to everyone Because hearing matters Remerciements Merci d avoir choisi la t l commande Smart Control d Unitron pour vos instruments auditifs Unitron Chez Unitron nous nous d vouons enti rement aux personnes souffrant de perte auditive Nous travaillons en troite collaboration avec des audioproth sistes afin de proposer des solutions de pointe adapt es aux besoins de tous Parce qu entendre est important Your Smart Control remote Hearing healthcare professional Telephone Model Serial number Replacement batteries One AAA 1 5 Volt Standard or Rechargeable Warranty Date of purchase Quick reference Changing batteries indicator lights blink alternately for 2 minutes Home button Telephone or program button 9 Program change button 10 LearnNow button 11 Battery compartment Battery size 1 On off switch AAA 2 Left both right switch 3 Left blue indicator light 4 Right red indicator light Low battery Warning e Scroll wheel left and right 6 butto
7. and or comfort clarity settings to your preferred levels After pressing the LearnNow button your hearing aids will beep if the command was successfully received CE Note The LearnNow button on your Smart Control may be deactivated by your hearing healthcare professional and therefore could be inactive CH Note On Passport and Yuu the LearnNow button will only work when your hearing aids are set to the automatic program Home button The Home button returns both of your hearing aids to their start up program similar to when you first turn on your hearing aids This button can be useful when you want your hearing aids regardless of the position of the Left Both Right switch to return to the start up program and the volume and comfort clarity settings when your hearing aids are first turned on Please refer to your hearing aid guide to determine which program is your start up program Accessories Your Smart Control can be used with a lanyard so that you can carry the remote around your neck or wrist Attach the lanyard to the remote as illustrated below 2 3 4 K gt t gt E Lu 5 6 Caring for your Smart Control Open the battery compartment and remove the battery if the remote control will not be used for long periods of time Do not use your Smart Control in the bath or shower or immerse it in water If your remote control does become wet do not attempt to dry it in an
8. ceramic tile If 8 kV air floors are covered with IEC 61000 4 2 synthetic material the relative humidity should be at least 30 Electrical fast 2 kV for power Not Mains power quality should transient burst supply lines applicable be that of a typical 1 kV for commercial or hospital IEC 61000 4 4 input output lines environment Surge 1 kV line s to line s Not Mains power quality should 2 kV line s to earth applicable be that of a typical IEC 61000 4 5 commercial or hospital environment Voltage dips lt 5 Ur 695 dip in Un Not Mains power quality should be short for 0 5 cycle applicable that of a typical commercial or interruptions hospital environment If the user and voltage 40 Ur 60 dip in Ur of the Model Smart Control variations on for 5 cycles requires continued operation power supply during power mains input lines 70 Ur 30 dip in Ur interruptions it is for 25 cycle recommended that the Model IEC 61000 4 11 Smart Control be powered from lt 5 Ur 695 dip in Ur an uninterruptible power supply for 5 sec or a battery Power frequency 3 A m 3 A m Power frequency magnetic 50 60 Hz magnetic field IEC 61000 4 8 NOTE Ur is the a c mains voltage prior to application of tl fields should be at levels characteristic of a typical location in a typical commercial or hospital environment he test level Table 202 49 Guidance and manufacturer s declaration electromagnetic immu
9. communication code Because of this code your Smart Control will not affect hearing aids worn by others A Your Smart Control uses the most modern components to provide an extremely reliable experience with virtually no interference from other devices However when operating the Smart Control near a computer terminal communication device such as a digital cell phone or other strong electromagnetic field it may be necessary to be at least 24 inches 60 centimeters away to ensure proper operation If your hearing aids do not respond to the Smart Control because of an unusual field disturbance move away from the disturbing field 20 Labeling The serial number and year of manufacture are located inside the battery compartment Please fill out the contact information sticker provided with your new Smart Control which is located inside the battery compartment 21 Aper u de votre t l commande Smart Control 1 22 Interrupteur marche arr t vous permet de mettre en marche et d arr ter votre t l commande ainsi que de la verrouiller pour viter d envoyer accidentellement des commandes Interrupteur gauche bilat ral droit vous permet de s lectionner instrument auditif que vous voulez r gler Voyant gauche bleu clignote pour indiquer que vous tes en train de r gler votre instrument auditif gauche Voyant droit rouge clignote pour indiquer que vous tes en train de r gler votre instru
10. e button Telephone button with Binaural Phone Binaural Phone exclusive to wireless styles of Quantum 20 and 12 Moxi 20 and 12 as well as Passport and Latitude 16 hearing aids To switch to the Binaural Phone program press the Telephone button once This will allow you to hear the conversation through both hearing aids automatically Press the Telephone button again and this will allow you to hear the phone conversation in only one ear To exit the Binaural Phone program press the Home button Program Change button To change the current listening program of your hearing aids press the Program Change button The hearing aid will advance to the next listening program Please refer to your hearing aid guide to determine which programs are available to you and their program beep notifications LearnNow button Available with Quantum 20 Moxi 20 Passport and Yuu hearing aids The LearnNow button teaches your hearing aids the volume and comfort clarity settings you prefer in different listening environments When you press the LearnNow button Smart Control sends a command to your hearing aids to learn your current settings more quickly By teaching your hearing aids you are personalizing your volume and comfort clarity settings and minimizing the need for adjustments when you are ina similar listening environment in the future A Note The LearnNow button should be pressed after you have adjusted the volume
11. e de vos instruments auditifs appuyez sur le bouton de votre t l commande Smart Control Lors du r glage du volume vos instruments auditifs peuvent mettre un bip Veuillez consulter le manuel de vos instruments auditifs pour obtenir plus de renseignements sur les bips de volume CH Remarque votre audioproth siste peut configurer la molette comme une commande de volume et vos boutons comme une commande de r glage du confort clart Bouton t l phone ou programme Pour passer au programme t l phonique appuyez sur le bouton t l phone Le bouton t l phone peut galement tre configur pour vous offrir un acc s direct un autre programme d coute particulier que votre audioproth siste a s lectionn pour vous Consultez votre audioproth siste pour savoir comment le bouton t l phone de votre t l commande a t configur Pour quitter le programme t l phonique appuyez sur le bouton d accueil Bouton t l phone avec programme t l phonique binaural le programme t l phonique binaural est exclusif aux mod les d instruments auditifs sans fil Quantum 20 et 12 Moxi 20 et 12 ainsi qu aux les instruments auditifs Passport et Latitude 16 Pour passer au programme t l phonique binaural appuyez une fois sur le bouton t l phone Cela vous permettra d entendre automatiquement la conversation dans vos deux instruments auditifs Appuyez a nouveau sur le bouton t l phone po
12. e used as directed by your hearing healthcare professional Smart Control uses a low power digitally coded inductive transmission to communicate to your hearing aids Although unlikely interference with medical devices such as pacemakers is possible Interference should not occur with normal use holding the remote comfortably in the hand 4 inches 10 centimeters or more from the body Therefore it is recommended that pacemaker users do not keep the remote control in a breast pocket Do not use Smart Control in explosion hazard areas Do not use Smart Control in locations forbidden to use electronic devices such as an airplane 18 Store your Smart Control in a safe location for CT and MRI scans or for other electromagnetic procedures A Changes or modifications made to the Smart Control not expressly approved by Unitron Hearing may void the user s authority to operate the equipment Battery warnings Never leave your remote control or batteries where small children and pets can reach them A Never put your remote control or batteries in your mouth If a battery is swallowed call a physician immediately Precautions Alf your Smart Control fails to operate after you have correctly inserted a new battery contact your hearing healthcare professional Always bring both your Smart Control and your hearing aids for service questions A Your Smart Control and your hearing aids are given a unique
13. er que vous tes en train de r gler vos deux instruments auditifs simultan ment 29 R glage de vos instruments auditifs avec la t l commande Smart Control Votre t l commande Smart Control est r tro clair e lorsqu elle est mise en marche pour la premi re fois puis chaque fois qu un bouton est utilis Cela vous permet de voir les boutons de la t l commande dans les environnements peu clair s R glage de la molette confort clart disponible sur les instruments auditifs Quantum 20 et 12 Moxi 20 et 12 Passport Latitude 16 Yuu et Next 16 La molette vous permet de r gler le H volume des paroles et des bruits de fond sortant de vos instruments auditifs Elle fournit galement une option de r glage de pr cision suppl mentaire qui surpasse la commande de volume traditionnelle Tournez la molette lentement vers le haut 30 pour augmenter la clart sonore notamment des paroles Tournez la molette lentement vers le bas pour augmenter le niveau de confort dans les environnements bruyants Lors du r glage de la molette vos instruments auditifs peuvent mettre un bip Veuillez consulter le manuel de vos instruments auditifs pour obtenir de plus amples renseignements sur votre fonction de r glage Boutons de commande de volume RQ Pour augmenter le volume de vos instruments auditifs appuyez sur le bouton de votre t l commande Smart Control Pour diminuer le volum
14. ft side of the remote To turn the remote control on slide the switch into the On or unlocked position sf To turn the remote control off slide the switch into the Off or locked position Sliding the switch to the Off position will avoid sending unintentional commands to your hearing aids while the remote is in your handbag or pocket for example unitron Replacing the battery The battery compartment is located on the back of the Smart Control 1 Slide the battery cover in the direction of the arrow 2 Grasp the old battery with your thumb and index finger and remove 3 Insert the new battery into the battery compartment in the correct position placing the battery s minus end into the compartment first 4 Slide the battery cover in the opposite direction of the arrow A Aunitron Dron Low battery warning When you see the left and right indicator lights blink alternating blue and red for two seconds your Smart Control is warning you that the battery in your remote is low You will see the warning every time you turn on your Smart Control or send a command to your hearing aids until you change the battery or the battery dies Caring for batteries Always discard batteries in a safe and environmentally friendly way To prolong battery life remember to turn the remote control off when not in use Operating instructions Before using your Smart Control turn on your
15. ids The scroll wheel allows you to manage the levels of speech and 8 background noise in your hearing aids and provides an additional fine tuning adjustment beyond a traditional volume control Scroll the wheel up slowly to increase the clarity of sounds such as speech Scroll the wheel down slowly to increase comfort in noisy listening situations As the wheel is adjusted your hearing aids may beep Please refer to your hearing aid guide for more information on your control feature Volume control buttons rs To increase the volume on your hearing aids press the button on your Smart Control To decrease the volume on your hearing aids press the button on your Smart Control As the volume is adjusted your hearing aids may beep Please refer to your hearing aid guide for more information on your hearing aids volume beeps CE Note Your hearing healthcare professional may configure the scroll wheel as your volume control and your buttons as your comfort clarity control Telephone or program button To switch to the telephone program Ki press the Telephone button The telephone button can also be set to provide you with direct access to another specified listening program that your hearing healthcare professional has selected for you Talk to your hearing healthcare professional to find out how your telephone button has been configured To exit the telephone program press the Hom
16. l Nettoyage de votre t l commande Smart Control Guide d d pannage Av rtissementS rosie a er E E tisane Declaration of conformity a Your Smart Control at a glance 1 On off switch turn your remote control on or off and also lock it to avoid sending unintentional commands 2 Left both right switch allows you to select the hearing aid you want to adjust 3 Left blue indicator light flashes to indicate your left hearing aid is being adjusted 4 Right red indicator light flashes to indicate your right hearing aid is being adjusted 5 Scroll wheel allows you to manage the levels of speech and background noise in your hearing aids 6 Volume control buttons adjusts the volume of your hearing aids 7 Home button returns your hearing aids to their start up program 8 Telephone or program button switches the hearing aid to the telephone program o Program change button advances your hearing aid to their next listening program 10 LearnNow button teaches your hearing aids your preferred settings in different listening programs 11 Battery compartment allows access to change the battery Control may be customized by your hearing healthcare professional so that the functions of 5 and 6 may be swapped DO NN HO 11 Dron Turning your Smart Control on and off Your Smart Control has an On Off or travel lock switch on the le
17. ment auditif droit Molette vous permet de r gler le volume des paroles et des bruits de fond sortant de vos instruments auditifs Boutons de commande de volume permet de r gler le volume de vos instruments auditifs Bouton d accueil permet de r tablir le programme de d marrage de vos instruments auditifs Bouton t l phone ou programme permet de faire passer les instruments auditifs au programme t l phonique Votre audioproth siste peut personnaliser le r glage afin que les commandes 5 et 6 puissent tre permut es 9 Bouton de changement de programme permet de faire passer vos instruments auditifs au prochain programme d coute 10 Bouton LearnNow permet vos instruments auditifs d enregistrer vos r glages pr f r s pour diff rents programmes d coute 11 Compartiment pile vous permet d avoir acc s la pile pour la remplacer Sunitron 23 Mise en marche et arr t de votre t l commande Smart Control Votre t l commande Smart Control est d t e d un interrupteur marche arr t ou de verrouillage de voyage sur le c t gauche Pour mettre la t l commande en marche faites glisser l interrupteur vers la position Marche ou la position de d verrouillage sf Pour arr ter la t l commande faites glisser l interrupteur vers la position Arr t ou la position de verrouillage Mettre l interrupteur sur la position Arr t permettra d viter d envoye
18. mmande Smart Control La t l commande Rapprocher la se situe trop loin t l commande vers vous La t l commande loigner la t l commande se situe trop pr s une distance maximale quivalente la longueur d un bras 40 Pour tout probl me ne figurant pas dans ce guide communiquez avec votre audioproth siste Si vous tes la recherche d un audioproth siste veuillez communiquer avec l agence la plus proche dont les coordonn es figurent au dos de ce livret 41 Avertissements A La t l commande Smart Control doit tre utilis e conform ment aux instructions de votre audioproth siste A La t l commande Smart Control utilise une 42 transmission inductive num ris e faible puissance pour communiquer avec vos instruments auditifs Bien qu improbables des interf rences avec des appareils m dicaux comme des stimulateurs cardiaques sont possibles Des interf rences ne devraient pas se produire dans le cadre d une utilisation normale c est dire en tenant bien la t l commande dans la main au moins 10 centim tres du corps Par cons quent il est recommand aux porteurs d un stimulateur cardiaque de ne pas mettre la t l commande dans une poche poitrine ALa t l commande Smart Control ne doit pas tre utilis e dans des zones pr sentant un danger d explosion A N utilisez pas la t l commande Smart Control dans les endroits o l utilisation d a
19. nity The Model Smart Control is intended for use in the electromagnetic environment specified below The customer or the user of the Model Smart d assure that it is used in such an environment Control shou Immunity IEC 60601 Compliance Electromagnetic environment guidance test test level level Portable and mobile RF communications equipment should be used no closer to any part of Smart Control including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms Not d 1 2 IEC 61000 4 6 150 kHz to applicable 80 MHz Radiated RF 3V m 3V m d 1 2 M 80 MHz to 800 MHz IEC 61000 4 3 80 MHz to d 2 3 M 800 MHz to 2 5 GHz 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equip ment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people
20. ns 7 8 Votre t l commande Smart Control Audioproth siste T l phone Mod le Num ro de s rie Piles de remplacement Une pile AAA 1 5 V classique ou rechargeable Garantie Date de l achat Aide m moire Remplacement des piles Type de pile 1 i 3 Avertissement de pile faible 5 les voyants gauche 6 et droit clignotent 7 alternativement 8 pendant 2 minutes Marche arr t 9 Bouton marche arr t Bouton gauche bilat ral droit Voyant gauche bleu Voyant droit rouge Molette Boutons Bouton d accueil Bouton t l phone ou programme Bouton de changement de programme 10 Bouton LearnNow 11 Compartiment pile Table of contents Table des mati res Your Smart Control at a glance EEN 2 Turning your Smart Control on and off 4 Replacing the battery 5 Operating instructions ssh 7 Adjusting your hearing aids with Smart Control 8 AGCOSSOMIOS eege gege 14 Caring for your Smart Control 15 Cleaning your Smart Control 16 Troubleshooting SUIS ss 17 Wami ES siennes 18 Aper u de votre t l commande Smart Control 22 Mise en marche et arr t de votre t l commande Smart COM Ol AE AEAEE EEE E O EEE 24 Remplacement de la pile 26 Instructions d utilisation ENEE 28 R glage de vos instruments auditifs avec la t l commande Smart Control 30 Lee Entretien de votre t l commande Smart Contro
21. ois que vous avez appuy sur le bouton LearnNow vos instruments auditifs mettront un bip si la commande a bien t re ue CH Remarque le bouton LearnNow de votre t l commande Smart Control peut avoir t d sactiv par votre audioproth siste et en cons quence tre inactif CH Remarque sur les mod les Passport et Yuu le bouton LearnNow ne fonctionne que lorsque vos instruments auditifs sont r gl s sur le programme automatique 35 Bouton d accueil Le bouton d accueil fait passer vos deux instruments auditifs leur programme de d marrage comme lors de leur mise en marche initiale Ce bouton peut tre utile lorsque vous souhaitez r tablir le programme de d marrage et les r glages de volume et de confort clart de la premi re mise en marche de vos instruments auditifs quelle que soit la position de l interrupteur gauche bilat ral droit Veuillez consulter le manuel de vos instruments auditifs pour d terminer votre programme de d marrage 36 Accessoires Votre t l commande Smart Control peut tre utilis e avec un cordon de mani re pouvoir la porter autour de votre cou ou de votre poignet Attachez le cordon la t l commande comme le montre l illustration ci dessous Entretien de votre t l commande Smart Control Ouvrez le compartiment pile et retirez la pile si vous ne pensez pas utiliser la t l commande pendant une longue p riode N utilisez
22. on 47 Guidance and manufacturer s declaration electromagnetic emissions The Model Smart Control is intended for use in the electromagnetic environment specified below The customer or the user of the Model Smart Control should assure that it is used in such an environment Emission test Compliance Electromagnetic environment guidance RF emissions Group 2 The Model Smart Control must emit CISPR 11 electromagnetic energy in order to perform its intended function Nearby electronic equipment may be affected RF emissions Class B The Model Smart Control is suitable CISPR 11 for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic Not applicable emissions IEC 61000 3 2 Voltage Not applicable fluctuations flicker emissions IEC 61000 3 3 48 Table 201 Guidance and manufacturer s declaration electromagnetic immunity The Model Smart Control is intended for use in the electromagnetic environment specified below The customer or the user of the Model Smart Control should assure that it is used in such an environment Immunity test IEC 60601 Compliance Electromagnetic test level level environment guidance Electrostatic 6 kV contact 6 kV Floors should be wood discharge ESD 8 kV air contact concrete or
23. oven or microwave Do not adjust any controls Open the battery compartment and remove the battery to allow your remote control to dry naturally for 24 hours Protect your remote control from excessive heat hair dryer vehicle glove box or dashboard Do not drop your remote control or knock it against hard surfaces Cleaning your Smart Control Do not use alcohol to clean your remote control Use a damp cloth to clean the outside of the remote Troubleshooting guide Refer to the troubleshooting table below if you are having problems with your Smart Control For problems with your hearing aids please consult your hearing aid guide Cause Possible remedy Indicator lights not flashing Not turned on Turn on Low dead battery Replace battery Poor battery contact Consult your hearing healthcare professional Battery upside down Insert battery plus side up Indicator lights flashing rapidly Low battery Replace battery Hearing aids not responding to Smart Control commands Holding the remote Move the remote control control too faraway closer to you Holding the remote Move the remote to a control too close maximum distance of one arm s length For any problems not listed in the guide contact your hearing healthcare professional If you do not have a hearing healthcare professional please contact the nearest office listed on the back page of this booklet 17 Warnings Smart Control should only b
24. pas votre t l commande Smart Control dans le bain ou sous la douche et ne l immergez pas dans l eau Si votre t l commande venait tre mouill e n essayez pas de la faire s cher dans un four traditionnel ou micro ondes N ajustez pas les commandes Ouvrez le compartiment pile et retirez la pile pour laisser votre t l commande s cher l air libre pendant 24 heures Prot gez votre t l commande contre la chaleur excessive s che cheveux bo te gants ou tableau de bord Ne laissez pas votre t l commande tomber ou heurter des surfaces dures 38 Nettoyage de votre t l commande Smart Control N utilisez pas d alcool pour nettoyer votre t l commande Utilisez un chiffon humide pour nettoyer l ext rieur de la t l commande 39 Guide de d pannage Consultez le tableau de d pannage ci dessous si vous rencontrez des probl mes avec votre t l commande Smart Control Veuillez consulter le manuel de vos instruments auditifs pour les probl mes relatifs vos instruments auditifs Symptome Solution possible Les voyants ne clignotent pas Pas en marche Mettre en marche Pile faible ou puis e Remplacer la pile Consultez Mauvais contact votre audioproth siste Pile a l envers Ins rer la pile avec le signe plus vers le haut Les voyants clignotent rapidement Pile faible Remplacer la pile Les instruments auditifs ne r pondent pas aux commandes de la t l co
25. ppareils lectroniques est interdite comme les avions A Rangez votre t l commande Smart Control dans un endroit s r lors de tomodensitogrammes d examens par IRM ou d autres proc dures lectromagn tiques Ales changements ou modifications apport s la t l commande Smart Control qui n ont pas t express ment approuv s par Unitron Hearing peuvent annuler l autorisation d utilisation de l quipement par l utilisateur 43 Avertissements concernant les piles Ne laissez jamais votre t l commande ou les piles la port e de jeunes enfants ou d animaux Ne mettez jamais votre t l commande ou les piles dans votre bouche Si une pile est ing r e appelez imm diatement un m decin Pr cautions Si votre t l commande Smart Control ne fonctionne pas une fois la pile neuve correctement install e communiquez avec votre audioproth siste Apportez toujours votre t l commande Smart Control ainsi que vos instruments auditifs pour toute question de r paration Votre t l commande Smart Control et vos instruments auditifs sont dot s d un code de communication unique Gr ce ce code votre t l commande Smart Control n a aucun effet sur les instruments auditifs d autres utilisateurs 44 Votre t l commande Smart Control utilise les composants les plus modernes pour vous offrir une exp rience extr mement fiable et une absence quasi totale d interf rences avec d
26. r accidentellement des commandes vos instruments auditifs lorsque la t l commande se trouve dans votre sac main ou votre poche par exemple 24 JAunitron 25 Remplacement de la pile Le compartiment pile est situ l arri re de la t l commande Smart Control T Faites glisser le couvercle du compartiment pile dans le sens de la fl che Attrapez la pile usag e l aide de votre pouce et de votre index puis retirez la Placez la pile neuve dans le compartiment pile en respectant la polarit et en commen ant par ins rer l extr mit n gative de la pile dans le compartiment Faites glisser le couvercle du compartiment dans le sens oppos de la fl che A a Jaunitron Zunitron Avertissement de pile faible Lorsque vous voyez les voyants gauche et droit clignoter alternativement du bleu au rouge pendant deux secondes votre t l commande Smart Control vous avertit que sa pile est presque puis e Vous verrez cet avertissement chaque fois que vous mettrez votre t l commande Smart Control en marche ou lorsqu un signal est envoy vos instruments auditifs et ce jusqu ce que la pile soit remplac e ou compl tement puis e Entretien des piles D barrassez vous toujours des piles de mani re s re et cologique Pour prolonger la dur e de vie de la pile pensez arr ter la t l commande lorsque vous ne l utilisez pas
27. rding to frequency of transmitter output power of m transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz W d 1 2 W d 1 2 Mi d 2 3 W 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Table 206 51 Unitron distributors Distributeurs Unitron Corporate office International 20 Beasley Drive P O Box 9017 Kitchener ON N2G 4X1 Canada Australia Australie Level 2 Norwest Quay 21 Solent Circuit Baulkham Hills NSW NSW 2153 Belgium Belgique Baron de Vironlaan 60 b 1700 Dilbeek Canada 20 Beasley Drive P O Box 9017 Kitchener ON N2G 4X1 China Chine No 78 Qi Ming Road Export Processing Zone District B Suzhou Industrial Park P R 215021 Denmark Danemarque Nitivej 10 DK 2000 Frederiksberg Germany amp European Representative Repr sentant Europ en Daimlerstrasse 22 70736 Fellbach Oeffingen Allemagne
28. ur entendre la conversation t l phonique dans une seule oreille Pour quitter le programme t l phonique binaural appuyez sur le bouton d accueil 33 Bouton de changement de programme Pour changer le programme d coute actuellement s lectionn pour vos instruments auditifs appuyez sur le bouton de changement de programme Les instruments auditifs passeront alors au programme d coute suivant Veuillez consulter le manuel de vos instruments auditifs pour d terminer les programmes disponibles pour vous et leurs notifications par bip Bouton LearnNow disponible sur les instruments auditifs Quantum 20 Moxi 20 Passport et Yuu ES Le bouton LearnNow indique vos instruments auditifs les r glages de volume et de confort clart que vous pr f rez selon les diff rents environnements sonores Lorsque vous appuyez sur le bouton LearnNow la t l commande Smart Control envoie une commande vos instruments auditifs leur intimant d enregistrer plus 34 rapidement vos r glages actuels Cet enregistrement par vos instruments auditifs vous permet de personnaliser vos r glages de volume et de confort clart et de minimiser la n cessit de proc der des r glages lorsque vous vous trouverez dans un environnement sonore semblable l avenir CH Remarque n appuyer sur le bouton LearnNow qu apr s avoir ajust les r glages de volume et ou de confort clart selon vos niveaux pr f r s Une f

Download Pdf Manuals

image

Related Search

Related Contents

Istruzioni d`uso Güntner Motor Management GMM sincon  Samsung SMART CAMERA NX200 Benutzerhandbuch  Sony HM-982RW User's Manual  Hotpoint RF725GP Range User Manual  Phonix HTCM8PUN mobile phone case  PHS基地局用アンテナ  KitchenAid KUDS40CVSS0 User's Manual    

Copyright © All rights reserved.