Home

Self Priming Shallow Well Jet Pumps

image

Contents

1. Franklin Electric Jet Pumps 49 SAFETY WARNINGS BEFORE OPERATING OR INSTALLING THIS PUMP READ THIS MANUAL AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS IMPORTANT READ THIS MANUAL BEFORE INSTALLING OR OPERATING THE PUMP A SAFETY CAREFULLY READ THESE SAFETY MESSAGES CAUTION Review instructions before operating WARNING ELECTRICAL PRECAUTIONS All wiring electrical connections and system grounding must comply with the National Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician Ah FOR DUAL VOLTAGE MOTORS Voltage change instructions are located on motor label or on wiring access cover 4h WARNING RISK OF ELECTRICAL SHOCK e Have an electrician provide electrical power to motor e Aground faultinterrupter GFI protected circuit is recommended for use with any electrical device operating near water e For recommended cable size see Table 1 e Motor must be grounded and terminal cover in place to reduce electrical shock hazard e Keep motor operating area as dry as possible e Always disconnect power before servicing e Not investigated for use in swimming pool areas Self Priming Shallow Well VOLTAGE WIRING INSTRUCTIONS 2 115V voltage change device LI terminal 230 a A 115 i board In 1 the motor s switch is shown before the black voltage change device is pressed down onto the voltage terminals In 2
2. Soupape de s ret Bouchon d amor age Bouchon de vidange Bouchon de nettoyage Aspiration Event Garniture d tanch it Puits Clapet de pied RSH A N Fig 2c PUITS PEU PROFOND R SERVOIR EN LIGNE AVEC CLAPET DE PIED R servoir Bouchon d amorcage anom tre facultatif Vid eo Ze oO e a Bay ny oupape de retenue o Maange nettoyage Aspiration Event Garniture d tanch it Puits Fig 2b PUITS PEU PROFOND AVEC SOUPAPE DE RETENUE EN LIGNE ao A AN Soupape d arr t CD i U Raccord union il en faut 2 s DY 3 Bouchon d amorcage N y 3 EN ranas e anometre 4 SE facultati E EG Or lt Q Bouchon gt vents Bouchon de amp vidange Bouchon de nn nettoyage we Aspiration Event WF A R servoir RO Garniture d tanch it SX Puits Scupane E Clapet de pied ando de s ret LS Fig 2d PUITS PEU PROFOND SYSTEME MONTE SUR LE RESERVOIR AVEC CLAPET DE PIED FONCTIONNEMENT A AVERTISSEMENT DE NE PAS FAIRE FONCTIONNER LA POMPE A SEC AVANT L AMORCAGE SINON LE JOINT D ETANCHEITE ET LAROUE DE TURBINE SERAIENT ENDOM MAGES DE FA ON PERMANENTE AMOR AGE REMARQUE La quantit d eau doit tre suffisante pour remplir la con duite d aspiration et le bo tier de la pompe Le temps d amorcage est fonc tion de la distance allant de la source d eau la pompe 5 15 min Utilisation d un cla
3. Branchement d eau Il faudrait raccorder le branchement d eau comme l indiquent les fig 2a b c ou d Le diam tre de la conduite de branchement d eau est en rapport direct avec le volume d eau requis et la longueur de la conduite elle m me Le diam tre de la conduite choisie devrait tre assez grand pour que la hauteur de la perte de charge tablie l aide du tableau 2 Diagramme de perte de charge ne d passe jamais plus de 20 pi 6 m AVERTISSEMENT PRECAUTIONS ELECTRIQUES Tous c blage connexions lectriques et mise la terre des systemes doivent se conformer au Code National d Electricit NEC et aux codes et ordonnances locaux Employez un lectricien autoris AVERTISSEMENT RISQUE DE CHOC LECTRIQUE e Cablage L emploi d un lectricien est recommand pour cabler et connecter le service lectrique la pompe Le manostat est c bl en usine au moteur et sa tension de c blage indiqu e sur un collant lorsqu applicable Veillez a ce que cette tension soit la m me que celle du courant d alimentation V rifiez les directives pour modifica tion de tension sur la plaque signal tique du moteur ou l int rieur du couvre borne Les lignes de courant de secteur seront connect es aux bornes du manostat marqu es Line Secteur Voyez illustr 1 Nous vous recommandons galement d acheminer un circuit s par entre le panneau de distribution et la pompe L usage d un GFI ou circuit prot g
4. as close as possible to the water source reduces the friction in the suction pipe and will give maximum capacities b Suction Pipe It is recommended that only new clean 1 1 4 inch pipe or hose be used If the pump is installed any appreciable dis tance away from the source of water the suction pipe should be increased to 1 1 2 inches Horizontal lengths of pipe must gradu ally slope upwards from the source of water to the pump to avoid air pockets in the line Thread compound should be used on all pipe joints and connections should be thoroughly tightened A foot valve must be installed and its operation should be checked since a leak will prevent proper operation of the system Make sure the foot valve is located so that it will be submerged at all times If a sandpoint or driven well is used install a check valve next to the pump suction instead of the foot valve Fig 2b All installations must have a foot valve or a check valve in the suction pipe c Pump to Tank Fittings The discharge pipe from the pump to the tank should be as short and direct as possible and should be the same size as that of the pump discharge tapping A check valve should never be installed between the pump and the tank d Service Line The service line should be connected as shown in Fig 2a b c or d The size of the service line required is gov erned entirely by the amount of water needed and the length of the pipe The pipe selected should be large enoug
5. ne peut tre consid r e par l utilisateur comme faisant partie du contrat de vente La seule obligation du vendeur ou de l Entreprise et le seul recours de l acheteur est le remplacement et ou la r paration du produit par l Entreprise comme il est d crit ci dessus LE VENDEUR OU L ENTREPRISE NE PEUT TRE TENU RESPONSABLE POUR TOUTE BLESSURE PERTE OU DOMMAGE DIRECT INDIRECT OU CONS CUTIF INCLUANT MAIS SANS S Y LIMITER LES DOMMAGES INDIRECTS OU CONS CUTIFS LI S UNE PERTE DE PROFITS UNE PERTE DE VENTES DES BLESSURES OU DES DOMMAGES MATERIELS OU TOUT AUTRE INCIDENT OU PERTE CONSECUTIVE RESULTANT DE L UTILISATION OU DE L IMPOSSIBILITE D UTILISER LE PRODUIT DE PLUS L UTILISATEUR ACCEPTE QU AUCUN AUTRE RECOURS N EST DISPONIBLE Avant de commencer utiliser le produit l utilisateur doit d terminer si ce produit est adapt a l usage pr vu et l utilisateur assume tous les risques et toutes les responsabilit s qui sont li s a cette utilisation LA GARANTIE ET LES MESURES CORRECTIVES DECRITES DANS LA PRESENTE GARANTIE LIMITEE CONSTITUENT UNE GARANTIE ET DES MESURES CORRECTIVES EXCLUSIVES EN LIEU ET PLACE DE TOUTE AUTRE GARANTIE ET MESURE CORRECTIVE EXPRESSE OU IMPLICITE ET TOUTE AUTRE GARANTIE ET MESURE CORRECTIVE EST EXPRESSEMENT EXCLUE INCLUANT MAIS SANS SY LIMITER TOUTE GARANTIE IMPLICITE DE QUALITE MARCHANDE OU D ADAPTATION A UN USAGE PARTICULIER Certaines juridictions et certains pays interdisent les exclusions ou les limitati
6. statements about the product made by the seller the Company the representatives or any other parties do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Seller s and the Company s only obligation and buyer s only remedy shall be the replacement and or repair by the Company of the product as described above NEITHER SELLER NOR THE COMPANY SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS LOST SALES INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT Before using the user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY EXPRESSED OR IMPLIED WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT EITHER APPLIES TO A PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED WARRANTIES GIVEN ABOVE Some states and countries do not allow the exclusion or limit
7. the motor s switch is set for 115V The black voltage change device is pressed down onto both terminals with the white arrow point on the voltage change device pointing directly to the 115V arrow point on the terminal board NOTE DO NOT move white lead wires on L1 amp L2 3 230 V In 3 the motor s switch is set for 230V The black voltage change device is pressed down onto only one terminal with the white arrow point on the voltage change device pointing directly to the 230V arrow point on the terminal board APPLICATION The shallow well jet pump is ideal for the supply of fresh water to rural homes farms and cabins This pump is suitable for installations where the vertical distance from the pump to the water level does not exceed 25 ft 7 6m including drawdown In off set installations friction losses in the suction pipe must be taken into consideration Refer to Table 2 Friction Loss Less at high altitudes PERFORMANCE U S Gallons per minute at 30 PSI at Total Suction Lift in feet below Litres per minute at 30 PSI at Total Suction Lift in metres below PuMPHP 1 5m 30m 4 5m 60m INSTALLATION a Pump Location The pump should be installed in a clean dry and ventilated location which provides adequate room for ser vicing and protection from freezing temperatures It should be bolted to a good foundation preferably concrete and provided with adequate drainage Locating the pump
8. unico derecho y opci n de determinar si repara o reemplaza el equipo piezas o com ponentes defectuosos La Compa a tiene la opci n de inspeccionar cualquier producto devuelto bajo los t rminos de la garant a para confirmar que est cubierto por la garant a antes aprobar la reparaci n o reemplazo seg n la garant a Esta garant a constituye la nica obligaci n de la Compa a y es el nico recurso que tiene el cliente si el producto tiene defectos Devuelva el producto defectuoso al sitio de compra para que sea considerado bajo la garant a DURACI N DE LA GARANT A PRODUCTOS 24 meses a partir de la fecha de compra por el cliente Los cepillos el impulsor o la leva en los modelos con motor de cepillo y o los impulsores de aletas flexibles no est n cubiertos por la garant a En caso de que no exista un comprobante adecuado de la fecha de compra el per odo efectivo de esta garant a comenzar a partir de la fecha de fabricaci n del producto MANO DE OBRA Y OTROS COSTOS La Compa a DE NINGUNA MANERA ser responsable por el costo de la mano de obra en el campo u otros cargos en que incurra cualquier cliente al retirar y o instalar alg n producto pieza o componente MEJORAS AL PRODUCTO La Compa a se reserva el derecho de cambiar o mejorar sus productos o cualquier parte de los mismos sin que por ello tenga la oblig aci n de realizar dicho cambio o mejora en las unidades vendidas y o despachadas con anterioridad T
9. y del largo de la tuber a La tuber a que se elija debe ser suficientemente grande para que la p rdida por fricci n determinada de la tabla 2 Tabla de P rdida por Fricci n nunca exceda los 20 pies 6 metros de presi n AVISO PRECAUCIONES EL CTRICAS Todo cableado conexiones el ctricas y sistemas de contacto a tierra deben cumplir con el C digo El ctrico Nacional NEC y con cualquier c digo y ordenanza local Contrate los servicios de un electricista con licencia Ah AVISO RIESGO DE DESCARGA EL CTRICA e Cableado Se debe emplear a un electricista para hacer el cableado y conectar el servicio el ctrico a la bomba El interruptor de presi n es cableado al motor en la f brica y el voltaje para el cual el motor est cableado est indicado en una etiqueta en los casos pertinen tes Aseg rese que el motor est cableado para el mismo voltaje que la fuente de electricidad Vea en la placa de la marca del motor o en la tapa de terminal interna las instrucciones para cambio de voltaje Las l neas el ctricas deben estar conectadas a los termina les del interruptor de presi n marcados como l nea line vea la fig 1 Se recomienda que se instale un circuito separado desde el panel de distribuci n hasta la unidad de la bomba Se recomienda se use un circuito protegido con interruptor por falla a tierra GFI con cualquier dispositivo el ctrico que se opere cerca del agua Instale un interruptor adecuado d
10. 4 pulgadas Si la bomba se instala a una distancia apreciable de la fuente de agua la tuber a de aspiraci n se debe aumentar a 11 2 pulgadas Las tuber as largas horizontales deben inclinarse gradualmente hacia arriba desde la fuente de agua hacia la bomba para evitar burbu jas de aire en la tuber a Se debe usar un compuesto o pegamen to para todas las roscas de las uniones de las tuber as y todas las conexiones se deben ajustar completamente Se debe instalar una v lvula de pie y se debe revisar su funcionamiento ya que una fuga prevendria el adecuado funcionamiento del sistema Aseg rese que la v lvula de pie est ubicada de tal manera que est sumergida en todo momento Si se usa una base al fondo del pozo o si es un pozo guiado instale una v lvula de chequeo junto a la aspiraci n de bomba en lugar de la v lvula de pie fig 2b Todas las instalaciones deben tener una v lvula de pie o una v lvula de chequeo en la tuber a de succi n c Empalmes de la Bomba al Tanque La tuber a de descarga que va de la bomba al tanque debe ser lo m s corta y directa posible y debe ser del mismo tama o que la toma de descarga de la bomba Nunca se debe instalar una v lvula de chequeo entre la bomba y el tanque d L nea de Servicio La l nea de servicio debe estar conectada tal como se muestra en la figura 2a b c o d El tama o requerido de la l nea de servicio depende completamente de la cantidad de agua que se necesite
11. EE O a citas Tap n de Limpieza SO Y Succi n g Respiradero C Sello de Pozo SZ Pozo JU Fig 2b POZO POCO PROFUNDO CON V LVULA DE CHEQUEO EN L NEA HORIZONTAL gt V lvula de apagado 4 Acoplamiento de empalme se necesitan 2 Tap n de Limpieza Succi n Respiradero Sello de Pozo Pozo V lvula de Pie Tanque J E Sa M Fig 2d POZO POCO PROFUNDO SISTEMA MONTADO EN EL TANQUE CON V LVULA DE PIE desfogue LES OPERACI N A AVISO NO OPERAR LA BOMBA ANTES DE CARGARLA EL SELLO Y EL PROPULSOR PODRIAN DANARSE PERMANENTEMENTE Cargado NOTA Usted necesitar suficiente agua para llenar la l nea s de succi n y el cuerpo de la bomba El tiempo de cargado depende de la distancia entre la fuente de agua y la bomba de 5 a 15 min Usando una v lvula de chequeo en la l nea 1 Abra la v lvula de descarga en la l nea de servicio y un grifo cercano para controlar el flujo de agua 2 Vierta agua limpia por el agujero del tap n de cargado en la parte superior del cuerpo de la misma hasta que el agua comience a rebalsarse por el orificio del respiradero 3 Coloque el tap n adjunto del respiradero ajuste flojamente el tap n con una herramienta 4 Contin e llenando la bomba con agua hasta que el agua comience a rebalsarse por el orificio de cargado 5 Instale el tap n adjunto de cargado y aj stelo con la mano 6 Encienda la bomba Si hay un grifo visible usted ver una descarga cor
12. RMINOS Y CONDICIONES GENERALES Esta garant a no tiene efecto si los da os se deben a fuerza mayor desgaste por uso normal servicios de mantenimiento normal y la piezas utilizadas para dicho servicio rayos o condiciones que est n fuera del alcance de la Compa a como tampoco tendr vigencia en aquellos productos que a criterio exclusivo de la Compa a hayan sido sujetos a negligencia maltrato accidente mal uso manipulaci n indebida alteraci n o instalaci n funcionamiento mantenimiento o almacenamiento indebidos o si se sobrepasan los valores m ximos recomendados estipulados en estas instrucciones Esta garant a quedar ANULADA si se hallan cualesquiera de las siguientes condiciones El producto se utiliza para prop sitos distintos a aquellos para los cuales fue dise ado y fabricado El producto no fue instalado de conformidad con las normas reglamentos y pr cticas comerciales aceptadas El producto se conecta a un voltaje distinto al que se indica en la placa de identificaci n La bomba se utiliz con fluidos distintos al agua dulce a temperatura ambiente aproximadamente La bomba funcion sin l quido se cort el suministro de l quido El cliente abri el alojamiento sellado del motor o desarm el producto El cable se cort a un largo menor que 0 9 m 3 pies EXENCI N DE RESPONSABILIDAD Toda afirmaci n verbal con respecto al producto por parte del vendedor la Compa a los representantes o cualquier otr
13. a parte no constituye garant a alguna no debe ser considerada como tal por el usuario y no forma parte del contrato de venta La nica obligaci n del vendedor y la Compa a y el nico recurso del comprador ser el reemplazo y o reparaci n que har la Compa a del producto tal como se describi anteriormente NI EL VENDEDOR NI LA COMPA A SER N RESPONSABLES POR CUALQUIER LESI N P RDIDA O DA O DIRECTO INCIDENTAL O INDIRECTO LO QUE INCLUYE SIN LIMITACI N DA OS INCIDENTALES O INDIRECTOS POR P RDIDA DE GANANCIAS DE VENTAS LESIONES PERSONALES O MATERIALES O CUALQUIER OTRO DANO INCIDENTAL O INDIRECTO QUE RESULTARA DEL USO O INCAPACIDAD DE USAR EL PRODUCTO Y EL USUARIO ACUERDA QUE NO HAY NINGUN OTRO RECURSO Antes de usarlo el usuario deber determinar la idoneidad del producto para el uso propuesto y asumir todos los riesgos y toda la responsabilidad que ello implique LA GARANT A Y RECURSO DESCRITOS EN ESTA GARANT A LIMITADA REPRESENTAN UNA GARANT A Y RECURSO EXCLUSIVOS Y SE OFRECEN EN LUGAR DE CUALQUIER OTRA GARANT A O RECURSO EXPL CITO O IMPL CITO POR EL PRESENTE SE EXCLUYEN EXPL CITAMENTE OTRAS GARANT AS Y RECURSOS INCLUSO PERO SIN LIMITARSE A CUALQUIER GARANT A IMPL CITA DE COMERCIALIZACI N O IDONEIDAD PARA UN PROP SITO ESPEC FICO EN LA MEDIDA EN QUE CORRESPONDA A UN PRODUCTO LA GARANT A ESTAR LIMITADA EN DURACI N A LOS PER ODOS DE LAS GARANT AS EXPRESAS DESCRITAS ANTERIORMENTE Algunos estados y pa s
14. ations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country DORON Toll Free Help Hotline 1 800 667 1457 RED LION 51 Burmac Road P O Box 429 Winnipeg Manitoba Canada R3C 3E4 Phone 877 337 2650 Fax 204 255 5214 www redlionproducts com Franklin Electric CONSIGNES DE S CURIT AVANT D INSTALLER OU D UTILISER CETTE POMPE PRIERE DE LIRE LE PRESENT GUIDE ET SUIVRE TOUTES LES REGLES DE SECURITE ET IN STRUCTIONS D UTILISATION S CURIT LIRE ATTENTIVEMENT LES AVIS DE S CURIT SE TROUVANT DANS LE PR SENT MANUEL ET SUR LA POMPE MISES EN GARDE Passez les instructions en revue avant d utiliser la pompe AVERTISSEMENT PRECAUTIONS ELECTRIQUES Tous c blage connexions lectriques et mise la terre des syst mes doivent se conformer au Code National d Electricit NEC et aux codes et ordonnances locaux Employez un lectricien autoris POUR LES MOTEURS BI TENSION Les instructions pour changer la tension sont sur l tiquette du moteur ou sur le couvercle d acc s aux files lectriques AVERTISSEMENT RISQUE DE CHOC LECTRIQUE e Faire appel un lectricien pour l alimentation lectrique du moteur e L usage d un circuit
15. de tension bornes 115V 2 115V Dans la figure 2 l interrupteur du moteur est r gl 115V Le dispositif noir de variation de tension est abaiss sur les bornes avec la fl che blanche sur le dispositif de variation de tension pointant directe ment vers la pointe de la fl che de la plaque 3 230 V Dans la figure 3 l interrupteur du moteur est r gl 230V Le dispositif noir de variation de tension est abaiss sur une seule borne avec la fl che blanche sur le dispositif de variation de tension pointant directement vers la pointe de la fl che de la plaque bornes 230V REMARQUE LES FILS BLANCS SUR L1 ET L2 NE DOIVENT PAS TRE ENLEV S 7 RENDEMENT Gallons U par minute a 30 Ib po Hauteur d l vation en pi Voir ci dessous evrom s ao 15 20 25 m fes fo 96 78 ss HAP rign Press s6 76 63 s1 36 Litres par minute 30 Ib po et hauteur totale d l vation en m tres Voir ci dessous CEVPOMPE 1 5m 30m 45m 60m 75m INSTALLATION a Emplacement de la pompe La pompe doit tre install e en un endroit propre sec et a r suffisamment spacieux pour proc der a son d pannage et pour la prot ger du gel Elle sera boulonn e sur une fondation solide en b ton de pr f rence et devra tre en mesure d assurer un drainage ad quat Son instal lation aussi pr s que possible de la source d eau diminue le frottement dans la conduite d asp
16. du carter de pompe le drain et les bouchons de drainage et de remplissage Enlevez le bouchon de drainage du r servoir le cas ch ant Pr voyez suffisamment de temps pour le drainage du syst me avant de remettre les bouchons 10 ENTRETIEN AVERTISSEMENT RISQUE DE CHOC LECTRIQUE a b c Avant d entretenir ou de r parer n importe quel appareil moteur vous devez couper le courant au panneau lectrique principal et d connecter le moteur et les accessoires Durant ce genre de travaux il faut toujours travailler prudemment Lubrification Inutile pour la pompe R f rez vous aux directives du fabricant du moteur pour la lubrification de celui ci Obturateur de regard de vidange Lorsque l encrassement pr sente un probl me la bonde filet e de 1 4 po NPT fournie permet un acc s facile pour le nettoyage l ouverture venturi Cette bonde est situ e directement sous l obturateur du regard de vidange dans le devant du carter IMPORTANT Avant de retirer ce bouchon de vidange teignez l arriv e de courant la pompe depuis le panneau principal de commandes lectriques Ouvrez un robinet dans le syst me pour en lib rer la pression Remplacement du joint tanche m canique Voyez illustr 3 Seuls des professionnels extr mement qualifi s pourront proc der a l entretien ou au d pannage d appareils ou dispositifs lectriques D montage 1 Eteignez arriv e de courant la pompe depuis
17. e desconexi n con fusible en la l nea y aseg rese que el cableado sea del tama o adecuado y que est bien aislado Cables de menor tama o entre el motor y la fuente de electricidad limitar n adversamente el encendido y la capacidad de carga del motor En la tabla 1 se recomiendan los calibres m nimos para los cables de extensi n del motor Para mayor seguridad la bomba y el motor deben estar conectados a tierra en el casco del pozo o en el panel de distribuci n Calibrador de Presi n Si se proporciona un calibrador de pre si n con la bomba o si Ud desea instalar uno ste se debe instalar en el hueco de 1 4 NPT en la parte superior del casco directamente junto a la abertura de descarga Control del Volumen de Aire Si no se usa un tanque de presi n permanente en el sistema de presi n entonces se debe usar un control de volumen de aire para mantener un colch n de aire en el tanque de presi n Vea las instrucciones en el manual del propietario del tanque de presi n V lvula Descargadora de Presi n Se recomienda que se instale una v lvula de seguridad de desfogue de alta presi n en alg n punto del sistema de agua Aseg rese que est ubicada cerca de la descarga de la bomba en un rea con drenaje adecuado Aseg rese de dirigir la v lvula de tal manera que el flujo del agua no pueda salpicar en ning n dispositivo el ctrico Fig 1 Conexiones El ctricas Linea de suminis tro de energ a y Tierra Inte
18. e the figures Loss of head in meters due to friction per 100 meters of pipe ao ss ia os fos nn Nominal Pipe Size TYPICAL INSTALLATIONS rE Relief Valve Clean Out Plug Suction Vent Well Seal Well Casing Foot Valve Relief Valve Priming Drain Plug Clean Out Plug Suction Vent Well Seal Well Casing Foot Valve Pressure Gauge optional Drain Plu id Clean Out Plug Suction Vent Well Seal Well Casing FIG 2B SHALLOW WELL WITH INLINE CHECK VALVE Shut Off Valve Union Coupling 2 are required 99 N19S OJ Priming Plug lt y 2 Pressure Gauge D A oS 2 optional G o Vent Plug Drain Pl A rain Fiug Clean Out NO LES Suction Plug rR Vent N 4 fark RAY amp Well Seal ay y Well Casing j Foot Valve Sa Relief gat Valve gt Drain FIG 2D SHALLOW WELL TANK MOUNTED SYSTEM WITH FOOT VALVE OPERATION A WARNING DO NOT RUN THE PUMP BEFORE PRIMING IT THE SEAL AND IMPELLER COULD BE PERMANENTLY DAMAGED PRIMING Note You will need enough water to fill the suction line and cas ing Priming time depends on distance from water source to pump 5 15 min Using an in line check valve 1 Open discharge valve on service line and nearby tap to monitor water flow 2 Pour clean water through priming plug opening at top of casing until water starts flowing out the vent plug hole 3 Install
19. enclosed vent plug tighten loosely with a wrench 4 Continue filling pump until water flows out of the priming hole 5 Install enclosed priming plug hand tighten 6 Start pump If a tap is visible you may see a short discharge of water which will last 5 10 seconds 7 Run the pump for 2 minutes and then shut it off Remove the vent plug and priming plug 8 You have completed the first priming cycle consisting of steps 2 to 7 This process will have to be repeated from 2 to 6 times depend ing on the length of your suction line Approximately one priming cycle for every 5 feet of suction line You will know when to stop because the pump will begin to pump water continuously 9 Once the pump begins pumping water continuously firmly tighten the vent plug and priming plug with a wrench 10 If the pump does not draw water within 8 tries shut it off and check for suction leaks Using a foot valve 1 Open discharge valve on service line and nearby tap to monitor water flow 2 Pour clean water through priming plug opening at top of casing until the suction line is full and water starts flowing out the vent plug hole You will need approximately 1liter of water for every 3 ft of suction line 3 Follow steps 3 through 6 above If within 2 minutes water is not being pumped continuously stop the pump Remove vent plug and priming plug Repeat steps 2 through 6 above If this does not work stop the pump and check the suct
20. es no permiten la exclusi n o las limitaciones sobre la duraci n de las garant as impl citas ni la exclusi n o limi taci n de responsabilidades por da os incidentales o indirectos por lo que puede que las exclusiones o limitaciones anteriores no correspondan en su caso particular Esta garant a le otorga a usted derechos legales espec ficos y es posible que usted tambi n tenga otros derechos que var an seg n el estado o pa s NOUS CN SERVICIO AL CLIENTE Linea directa 1 800 667 1457 RED LION 51 Burmac Road P O Box 429 Winnipeg Manitoba Canada R3C 3E4 Fax 204 255 5214 www redlionproducts com 232893 Rev 5 11 12
21. h so that the friction loss determined from Table 2 Friction Loss Chart will never exceed 20 ft 6m head WARNING ELECTRICAL PRECAUTIONS All wiring electrical connections and system grounding must comply with the National Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician WARNING RISK OF ELECTRICAL SHOCK e Wiring An electrician should be employed to do the wiring and connect the electrical service to the pump The pressure switch is wired to the motor at the factory and the voltage for which the motor is wired is indicated by a sticker where applicable Make sure the motor is wired for the same voltage as the power supply Refer to the motor nameplate or inside terminal cover for voltage changing instructions The power lines should be connected to the pressure switch terminals marked line see Fig 1 It is recommended that a separate circuit be led from the distribution panel to the pump unit A ground fault interrupter GFI protected circuit should be used for all electrical devices operating near water Install a proper fused disconnect switch in the line and make certain the wiring is adequately sized and well insulated Undersized wire between the motor and the power source will adversely limit the starting and load carrying abilities of the motor Minimum wire sizes for motor branch circuits are recommended see Table 1 For added safety the pump and motor should be g
22. he carbon ring towards the ceramic seat 5 Replace the impeller 6 and the diffuser 4 6 Replace the casing 2 making sure that the gasket is not damaged and is in place 7 Reconnect the tubes to the casing and to the pressure switch 8 Reconnect the power 9 Prime pump start check for leaks PALL i A EET af ZE SN mis N NY HS M 4 i TROUBLESHOOTING a b c d e Motor will not start 1 No power to pressure switch due to blown fuses open switches or loose connections 2 Pump pressure switch not closed Pump fails to deliver water 1 Pump not completely primed 2 Suction lift is too great 3 Foot valve is either not submerged buried in the mud or plugged Pump loses prime 1 Air leaks in suction line 2 Well draw down too far 3 Faulty foot valve Pump delivers water but not at rated capacity 1 Leaks in suction or discharge line 2 Foot valve suction line impeller or nozzle are partially plugged 3 Suction lift is greater than recommended 4 Improper impeller rotation or low speed 5 Venturi or diffuser is plugged 6 Motor is wired for improper voltage 7 Motor does not come off starting windings improper motor switch adjustment Pump starts and stops too often 1 Faulty air volume control 2 Air leaks in tank above the water level 3 Incorrect setting on pressure switch 4 Tank is water logged or too small for applicati
23. i n 2 Nivel de bombeo de agua del pozo est muy abajo 3 V lvula de pie defectuosa La bomba saca agua pero en menor cantidad de lo que debe 1 Fugas en la l nea de aspiraci n o descarga 2 La v lvula de pie la l nea de aspiraci n el propulsor o la boquilla est n parcialmente bloqueados 3 La altura de aspiraci n es mayor que la que se recomien da Rotaci n inadecuada del propulsor o baja velocidad El venturi o el difusor est n bloqueado El motor est cableado para voltaje inadecuado Motor defectuoso ajuste inadecuado del interruptor del mo tor La bomba se prende y apaga muy seguido 1 Control de volumen de aire defectuoso 2 Fuga de aire en el tanque por encima del nivel del agua 3 Ajuste incorrecto del interruptor de presi n 4 El tangue est saturado de agua o es muy peque o para su aplicaci n oo GARANTIA LIMITADA Para consideraciones de la garantia Franklin Electric Company Inc y sus subsidiarios denominada de ahora en adelante la Compania garantiza que los productos especificados en esta garantia estan libres de defectos en los materiales y en la mano de obra de la Compania Durante el periodo y sujeto a los t rminos estipulados en este documento la Compania reparara o reemplazara al cliente o usuario original cualquier parte del producto que presente defectos materiales o de fabricaci n atribuibles a la compa a En todo momento la Compa a tendr y poseer el
24. ion line for leaks 4 Once the pump begins pumping water continuously firmly tighten the vent plug and priming plug with a wrench DRAINING Should the unit be subject to freezing it will be necessary to drain the pump and tank To do this shut off the power to the pump at the main electrical service panel Open a tap in the water system to release the pressure Remove the drain and fill plugs from the pump casing Remove the pressure tank drain plug if so equipped Allow ample time for the system to drain before reinstalling the plugs MAINTENANCE 4h WARNING RISK OF ELECTRICAL SHOCK Before servicing motor operated equipment shut off the power at the main electrical panel and disconnect the power supply from motor and accessories Use safe working practices during servicing of equipment a Lubrication The pump requires none Refer to motor manufac turer s instructions for motor lubrication b Cleanout Plug For applications where clogging is a problem a 1 4 NPT plug has been provided for access to clean the nozzle c venturi This plug is located directly below the suction opening in the front of the casing IMPORTANT Before removing the cleanout plug shut off the power to the pump at the main electrical panel Open a tap in the water system to release the pressure Replacing Mechanical Seal See Fig 3 Only duly qualified persons should perform maintenance on electrical and or mechanical devices Disasse
25. iration et permet d en pousser au maximum les capacit s de rendement b Conduite d aspiration Nous vous recommandons de n employer que des conduites ou tuyaux propres et neufs de 1 1 4 po Si vous installez la pompe une distance appr ciable quelle qu elle soit de la source d eau la conduite d aspiration sera largie jusqu 1 1 2 po Les sec tions horizontales de tuyauterie seront graduellement inclin es vers le haut depuis la source d eau jusqu la pompe pour viter la formation de poches d air dans la canalisation Un enduit pour filetage couvrira tous les joints et les raccords seront fortement serr s Un clapet de pied doit tre install et v rifi du fait qu une fuite pourrait emp cher le fonctionnement normal du syst me Assurez vous que le clapet de pied soit constamment submerg Si une pointe filtrante ou un puits instantan est employ e installez un clapet de non retour au lieu d un clapet de pied proximit de la source d aspiration de la pompe Voyez l illustration 2b Toutes les installations doivent avoir un clapet de pied et une soupape de retenue dans le tuyau d aspiration c Raccordement de la pompe au r servoir La conduite de refoule ment de la pompe au r servoir devrait tre aussi courte et directe que possible et son diam tre devrait tre le m me que celui de l orifice de refoulement de la pompe Il ne faudrait jamais installer un clapet de retenue entre la pompe et le r servoir d
26. is e une ou plusieurs se maines les composantes tanches seront install es s ches non lubrifi es 3 Remontez la plaque d tanch it sur le moteur 4 Lubrifiez l g rement l eau savonneuse la partie pivot ante 7 de la garniture d tanch it et glissez la sur l arbre bague du charbon tourn e vers l ext rieur du siege de l embase de c ramique 5 Replacez la roue motrice 6 et le diffuseur 4 6 Replacez le carter 2 en vous assurant que le Venturi soit pos de mani re appropri e et que le joint n est pas endom mage avant de le reposer 7 Remontez les tubes dans le carter et le manostat 8 Rebranchez le courant 9 Amorcez la pompe mettez la en marche sans omettre de v rifier les fuites possibles GUIDE DE D PANNAGE a b c d e Le moteur ne d marre as 1 Le manostat ne fonctionne pas en raison de fusibles saut s d interrupteurs ouverts ou de mauvais branchements 2 Le manostat de la pompe est ouvert Aucun pompage 1 La pompe n est pas bien amorc e 2 La hauteur d aspiration est trop lev e 3 Immersion incompl te enfouissement dans la boue ou colmatage du clapet de pied Perte d amor age 1 Fuites d air dans la conduite d aspiration 2 Le pompage entra ne une trop grande d pression du niveau d eau 3 Le clapet de pied est d fectueux La pompe refoule l eau un d bit insuffisant 1 Fuites dans les canalisations d aspiration ou de refo
27. le panneau prin cipal de commandes lectriques et d connectez le moteur 2 Ouvrez un robinet dans le syst me pour en lib rer la pression 3 Enlevezle drain et les bouchons pour permettre le drainage de la pompe 4 D branchez le tube menant au manostat 5 Enlevez les 4 boulons 1 puis le carter de pompe 2 6 Forcez le diffuseur 4 hors du carter au moyen de deux tournevis t te fendue en guise de leviers 7 Enlevezle couvercle 5 ins rez un tournevis pour emp cher l arbre de tourner pendant le d vissage de la roue 6 moteurs GE S il s agit de moteurs de marque A O Smith enlevez le couvercle arri re au moyen d une cl plate ins r e sur le c t travers l ouverture d extr mit du carter de pompe La roue est filet e main droite Si elle ne parvient pas tournermanuellement ins rez un objet plat dans son aube 8 Glissez le joint tanche rotatif 7 sur l arbre et enlevez la plaque d tanch it 8 9 Enlevez le si ge de c ramique du joint d tanch it 9 de la plaque de joint Remontage 1 Nettoyez consciencieusement toutes les pi ces enlev es avant de les remonter 2 Lubrifiez l g rement l eau savonneuse la calotte de caoutchouc de l embase de c ramique 9 et enfoncez la avec les pouces seulement dans la plaque du joint Veillez ce que la surface lisse du si ge de l embase de c ramique soit tourn e vers l ext rieur AVIS Si la pompe demeure inutil
28. mbly Shut off the power to the pump at the main service panel and disconnect the power supply from motor 2 Open a tap in the water system to release the pressure 3 Remove the drain and fill plugs to allow the pump to drain 4 Disconnect the tube leading to the pressure switch 5 Remove the four bolts 1 and remove casing 2 6 Pry the diffuser 4 out of the casing using two slotted screw drivers for leverage 7 Remove cap 5 and insert a screwdriver to prevent the shaft from turning while unscrewing the impeller 6 GE motors For A O Smith motors remove rear cover and hold the shaft using a flat wrench inserted from the side through the opening in the end housing Impeller has right hand thread If impeller cannot be turned by hand insert a flat object into the impeller vane 8 Slip the rotating seal 7 off the shaft and remove the seal plate 8 9 Remove the ceramic seal seat 9 from the seal plate Reassembly 1 Clean all the parts thoroughly before assembling 2 Lightly lubricate soapy water the rubber cap on the ceramic seal 9 and push it into the seal plate using thumbs only Make sure the smooth surface of the ceramic seat faces outwards NOTE If the pump will remain out of service for longer than one week the seal components must be installed dry no lubrication 3 Put the seal plate back on the motor 4 Lubricate the rotating seal 7 with soapy water and slip it onto the shaft with t
29. nda se use un circuito protegido con interruptor por falla a APLICACION tierra GFI con cualquier dispositivo que se opere cerca del agua La bomba a chorro para pozo poco profundo es ideal para el abas e Vea en la Tabla 1 el tama o de cable recomendado tecimiento de agua potable en casas rurales granjas ranchos y e El motor debe estar conectado a tierra y la tapa del terminal caba as Esta bomba es para lugares donde la distancia vertical debe estar en su sitio para reducir el riesgo de una descarga entre la bomba y el nivel del agua no excede los 25 pies 7 6 metros el ctrica desde el nivel m s bajo del agua En instalaciones donde hay cierta e Mantenga el rea de operaci n del motor tan seca como sea distancia entre el pozo y la bomba se debe tomar en consideraci n posible la p rdida por la fricci n en la tuber a de aspiraci n vea la tabla 2 e Desconecte siempre la electricidad antes de darle servicio Tabla de P rdida por Fricci n e Nose ha investigado su uso en el area de albercas o piscinas Menor a mayores alturas INSTRUCCIONES DE CABLEADO DE TENSI N 1 2 115V 3 230 V Dispositivo de cambio de tensi n Placa de terminales En la figura 1 el interruptor En la figura 2 el interruptor del motor esta En la figura 8 el interruptor del motor del motor se muestra antes ajustado para 115V El dispositivo negro de cambio est ajustado para 230V El dispositivo de presionar hacia abajo el de te
30. nsi n est presionado hacia abajo sobre am negro de cambio de tensi n est presio dispositivo negro de cambio bos terminales con la flecha blanca del dispositivo nado hacia abajo sobre un solo terminal de tensi n sobre los termina de cambio de tensi n apuntando directamente ala con la flecha blanca del dispositivo de les de tensi n punta de la flecha de 115V de la placa de terminales cambio de tensi n apuntando directa NOTA NO QUITAR LOS CABLES BLANCOS DE L1 Y L2 a a de la placa de terminales REDIMIENTO Gal Amer por minuto a 30 libras de presion en Altura de Aspiracion Total en pies de altura Cardago de bomba reid mo es 1 2 HP High Press Cas rs 63 s1 36 Litros por minuto a 30 libras de presi n PSI en Altura de Aspiraci nTotal en metros de altura 36 7 Cardago de bomba 7 5m us 367 3147 3 26 5 39 4 13 6 INSTALACI N a Ubicaci n de la Bomba La bomba se debe instalar en un rea limpia seca y ventilada que proporcione suficiente espacio para su mantenimiento y protecci n contra temperaturas de congelamiento Debe estar sujeta con pernos a una buena base preferentemente de concreto y con desag e adecuado El colocar la bomba lo m s cerca posible a la fuente de agua reduce la fricci n en la tuber a de aspiraci n y proporcionar las capacidades m ximas Tuber a de Aspiraci n Se recomienda se use solamente una tuber a o manguera nueva limpia de 11
31. ombear agua continuamente ajuste firmemente los tapones del respiradero y de cargado con una herramienta Drenaje Si la unidad es expuesta al congelamiento entonces ser necesario drenar la bomba y el tanque Para hacerlo apague la electricidad de la bomba en el panel principal de servicio el ctrico Abra un grifo en el sistema de agua para reducir la presi n Quite los tapones de drenaje y cargado del casco de la bomba Quite el tap n de drenaje del tanque de presi n si lo tuviera Deje que pase tiempo suficiente para que el sistema se drene antes de volver a poner los tapones MAINTENMIENTO A AVISO RIESGO DE DESCARGA ELECTRICA Antes de prestar servicio a un equipo operado a motor desconecte la electricidad al motor en el panel el ctrico principal y desconecte el suministro el ctrico del motor y los accesorios Practique reglas de seguridad de trabajo cuando preste servicio al equipo a Lubricaci n La bomba no la necesita Vea las instrucciones del fabricante del motor con respecto a lubricaci n del motor b Tap n de Limpieza Para los casos en que haya problemas de obstrucci n se ha proporcionado un tap n de 14 NPT para tener acceso a limpiar la boquilla venturi Este tap n est ubicado directamente debajo de la apertura de aspiraci n en la parte frontal del casco de la bomba IMPORTANTE Desconecte la electricidad a la bomba desde el panel principal de servicio el ctrico antes de quitar el tap n de lim
32. on LIMITED WARRANTY For warranty consideration Franklin Electric Company Inc and its subsidiaries hereafter the Company warrants that the products specified in this warranty are free from defects in material or workmanship of the Company During the time periods and subject to the terms and conditions hereinafter set forth the Company will repair or replace to the original user or consumer any portion of this product which proves defective due to materials or workmanship of the Company At all times the Company shall have and possess the sole right and option to determine whether to repair or replace defective equipment parts or components The Company has the option to inspect any product returned under warranty to confirm that the warranty applies before repair or replacement under warranty is approved This war ranty sets forth the Company s sole obligation and purchaser s exclusive remedy for defective product Return defective product to the place of purchase for warranty consideration WARRANTY PERIOD PRODUCTS 24 months from date of purchase by the user No warranty on brushes impeller or cam on models with brush type motors and or flex vane impellers In the absence of suitable proof of the purchase date the effective period of this warranty will begin on the product s date of manufacture LABOR ETC COSTS The Company shall INNO EVENT be responsible or liable for the cost of field labor or other charges incurred by any c
33. ons de dur e d une garantie implicite ou l exclusion ou la limitation des dommages indirects ou cons cutifs les limitations ou exclusions ci dessus pourraient donc ne pas s appliquer votre cas Cette garantie vous donne des droits l gaux sp cifiques et vous pourriez galement jouir d autres droits qui varient selon la juridiction ou le pays oe Se PEA oe 1 SERVICE ALA CLIENTELE Ligne directe a 1 800 667 1457 RED LION 51 Burmac Road P O Box 429 Winnipeg Manitoba Canada R3C 3E4 Fax 204 255 5214 www redlionproducts com 12 Bombas a Chorro GY Frankin Electric Autocargables Para Pozo Poco Profundo 4h ADVERTENCIAS DE SEGURIDAD LEA ESTE MANUAL Y SIGA TO DAS LAS REGLAS DE SEGURIDAD ANTES DE INSTALAR U OPERAR ESTA BOMBA 4h SEGURIDAD LEA CUIDADOSAMENTE ESTOS MENSAJES DE SEGURIDAD EN ESTE MANUAL Y EN LA BOMBA CUIDADO Revise cuidadosamente las instrucciones antes de usarla AVISO PRECAUCIONES EL CTRICAS Todo cableado conexiones el ctricas y sistemas de contacto a tierra deben cumplir con el C digo El ctrico Nacional NEC y con cualquier c digo y ordenanza local Contrate los servicios de un electricista con licencia PARA MOTORES DE DOS VOLTIOS Las instrucciones por el cambio de voltio estan sobre la etiqueta del mot r o la cubierta del alambrado AVISO RIESGO DE DESCARGA EL CTRICA e Haga que un electricista le conecte la electricidad al motor e Serecomie
34. par un interrupteur de masse d fectueuse IMD est recommand avec tout appareil lectrique fonctionnant dans l eau ou proximit de celle ci Installez un disjoncteur fusible appropri dans la ligne secteur et veillez ce que le cable soit de dimension ad quate et quill soit bien isol L emploi d un fil trop petit entre le moteur et la source de courant limitera les capacit s de d marrage et de charge du moteur On recommande des grosseurs minimales pour les fils des circuits de d rivation du moteur Tableau 1 Il sera pr f rable pour ajouter encore la s curit de mettre la pompe et le moteur la masse sur le cuvelage du puits ou de les mettre la terre dans le panneau de distribution Manometre Si un manometre est fourni avec la pompe ou si vous d sirez en l installer un il doit correspondre l orifice de 1 4 po NPT se trouvant sur la partie avant du bo tier directement a c t de l orifice de refoulement Commande du volume d air Si une installation sous pression n est pas munie d un r servoir pression constante il faut installer une commande du volume d air pour pr server une couche d air dans le r servoir sous pression Consultez le manuel fourni par le fabricant du r servoir pression Soupape de d charge Une soupape de s curit de d charge haute pression devrait tre install e un point quelconque du r seau d alimentation Veillez la placer proximit de la d charge de la
35. pet anti retour sur conduite 1 Ouvrir le clapet de refoulement se trouvant sur la conduite de raccordement et pr s du robinet pour surveiller le d bit d eau 2 Verser de l eau propre dans lorifice situ sur le dessus du bo tier et o sera install ult rieurement le bouchon d amorgage orifice d amorcage jusqu ce que l eau commence sortir de l orifice destin recevoir le bouchon vents 3 Installer le bouchon vents fourni et serrer mod r ment l aide d une cl 4 Continuer remplir la pompe jusqu ce que l eau sorte par l orifice d amorcage 5 Installer le bouchon d amorcage fourni et serrer a la main 6 Mettre la pompe en marche Si celle ci est munie d un robinet vis ible il est possible que vous observiez un refoulement de courte dur e 5 10 secondes 7 Faire fonctionner la pompe pendant 2 minutes puis l arr ter Retirer le bouchon a vents et le bouchon d amorcage 8 Vous avez termin le premier cycle d amorcage qui consiste des tapes 2 7 Ce processus devra tre r p t de 2 6 fois selon la longueur de votre conduite d aspiration Environ un cycle d amorcage pour chaque longueur de 5 pieds de conduite d aspiration Vous interrompez le processus quand la pompe commence pomper de l eau de fa on continue 9 ce moment bien serrer le bouchon vents et le bouchon d amorcage au moyen d une cl Si la pompe ne pompe pas d eau apr s 8 essais co
36. pieza Abra un grifo en el sistema de agua para reducir la presi n C mo Reemplazar el Sello Mec nico Vea la Fig 3 Sola mente personas debidamente calificadas deber an dar manten imiento a dispositivos el ctricos y o mec nicos Desensamblaje 1 Desconecte la electricidad al motor en el panel principal de servicio y desconecte el suministro el ctrico del motor 2 Abra un grifo en el sistema de agua para reducir la presi n 3 Quite los tapones de drenaje y de cargado para dejar que la bomba se drene 4 Desconecte la tuber a que va al interruptor de presi n 5 Quite los 4 pernos 1 y quite el casco de la bomba 2 6 Palanquee el difusor 4 fuera del casco de la bomba utilizan do dos destornilladores ranurados para obtener equilibrio 7 Quite la tapa 5 e inserte un destornillador para evitar que el eje d vueltas cuando destornille el propulsor 6 motores General Electric Para los motores A O Smith quite la tapa posterior y sujete el eje utilizando una herramienta plana introducida por el costado a trav s de la apertura al fondo del casco de la bomba El propulsor tiene rosca para mano derecha Si no se puede voltear a mano el propulsor en tonces inserte un objeto plano en la paleta del propulsor 8 Deslice el sello rotativo 7 fuera del eje y quite la plancha selladora 8 9 Quite el asiento del sello de cer mica 9 de la plancha selladora Ensamblaje 1 Limpie todas las parte completamen
37. pompe dans un endroit pouvant offrir un drainage ad quat Assurez vous de la diriger de telle mani re qu aucun coulement d eau aussi puissant soit il ne puisse clabousser un dispositif lectrique quel qu il soit Fig 1 Branchements lectriques C ble d alimentation Prise de terre Manostat _ Moteur charge TABLEAU 1 LONGUEUR MAXIMALE DES FILS EN PIEDS Bas e sur une baisse de voltage approximative de 3 TABLEAU 2 DIAGRAMME DE PERTE DE CHARGE DES CONDUITES DE PLASTIQUE Perte de hauteur totale de charge en pieds caus e par le frottement 100 pieds de conduite Perte de hauteur totale de charge en metres caus e par le frottement par 100 metres de conduite AAA US min 3 4 1 4 1 2 4 ss fats 000 00 a n 046 022 ee ee 065 ot oo o o hopa 066 ot CS sol ae 0 os CS o sur 15 065 pe 6050 1870 4 99 235 foe o 7050 2200 600 2 63 0 88 nate nin 20mm 260m 32mm 40mm somm conduite L Min 3 7 as ea ms fom ra ese os oar so fes Jas 108 los es so a os 0 ae raso 392 45 os Dans le cas de conduites d acier galvanis doublez les chiffres ci dessous INSTALLATIONS CARACT RISTIQUES R servoir Bouchon d amor age Manom tre facultatif Bouchon de nettoyage Aspiration vent Garniture d tanch it Puits Clapet de pied servoir wx 7 RX J R SS a
38. prot g par un interrupteur de masse d fectueuse IMD est recommand avec tout appareil lectrique fonctionnant dans l eau ou proximit de celle ci Le Tableau 1 indique les c bles recommand s Faire appel un lectricien pour l alimentation lectrique du moteur Le moteur doit tre mis la terre et le couvercle des bornes cor rectement install afin de r duire les risques d lectrocution Garder la zone de travail aussi s che que possible Toujours couper l alimentation avant de proc der l entretien Cette pompe n est pas con ue pour etre utilis e dans une piscine Pompes Jet Auto amor antes Pour Puits Peu Profond APPLICATION La pompe jet pour puits peu profond est id ale pour approvision ner en eau fra che les r sidences rurales les fermes et les chalets Cette pompe convient aux installations dont la distance verticale entre la pompe et le niveau de l eau ne d passe pas 25 pi 7 6 m compte tenu de la d pression du niveau d eau Pour ce qui est des installations d cal es il faut tenir compte des pertes de charge dans la conduite d aspiration Voir le Tableau 2 Diagramme de perte de charge Hauteur r duite aux altitudes lev es DIRECTIVES DE C BLAGE DE TENSION Dispositif de Variation de tension Plaque bornes Dans la figure 1 l interrupteur du moteur est montr avant que le dispositif de variation de tension soit abaiss sur les bornes
39. rounded to the well casing or the ground in the distribution panel f Pressure Gauge If a pressure gauge is supplied with the pump or if you wish to install a pressure gauge it should be installed into the 1 4 NPT hole on the front of the casing directly beside the discharge opening g Air Volume Control If no perma pressure tank is used in a pres sure system an air volume control must be used to maintain an air cushion in the pressure tank Refer to pressure tank owner s manual for instructions h Pressure Relief Valve A high pressure safety relief valve is rec ommended to be installed at some point in the water system Ensure its location is near the discharge of the pump in an area with adequate drainage Be sure to direct the valve such that any water flow could not spray toward any electrical devices Fig 1 Electrical Connections Pressure _ Switch Motor Load TABLE 1 MAXIMUM WIRE LENGTH FT Wire Gauge AWG Motor Wire Gauge AWG TAP Volts 0 254 50 ft 100 ft 1508 200 m fus Lu 4 2 o 8 Ga us ou wo s 6 ms ae 0 e 6 Based on approx 3 voltage drop TABLE 2 FRICTION LOSS FOR PLASTIC PIPE Loss of head in feet due to friction per 100 feet of pipe Nominal Pipe Size 3 7 F 1 1 4 1 1 2 os 0 46 0 22 0 52 0 65 0 79 0 23 0 95 1 87 2 33 0 69 2 83 Es EN 5 0 31 f 0 23 For galvanized pipe doubl
40. rruptor de presi n Motor Carga Basada en una baja de voltaje aproximada de 3 TABLA 2 TABLA DE PERDIDA POR FRICCION PARA TUBERIAS DE PLASTICO P rdida de presi n en pies debido a la fricci n por 100 pies de 3 4 MH 9 tuberia Tama o Nominal de Tuberia Gal Amer 1 15 0 AE ses 175 046 0o22 ros 245 065 ot T080 325 086 oar s50 416 110 052 reso 517 138 088 e050 1870 499 233 069 Duplique el numero para tuberias galvanizadas P rdida de presi n en metros debido a la fricci n por 100 metros de tuber a Tama o Nominal 0 30 0 13 1 64 1 15 INSTALACIONES T PICAS Tanque mes gt A D Al V lvula de N desfogue amp A FN A gt gt P lt Tap n de Cargado Man metro C OSa opcional Y Le Drenaje e UsS O 4 San Tap n de Respiradero Co Tap n de drenaje Tap n de Limpieza F NS Al Succi n Respiradero c Sello de Pozo Pozo Valvula de Pie PAS JN me ea Fig 2a POZO POCO PROFUNDO CON VALVULA DE PIE Valvula de desfogue Tapon de Cargado Tap n de drenaje Succi n Respiradero Sello de Pozo Pozo V lvula de Pie Tap n de Cargado E V lvula de AN N E Gr a desfogue CF LA D 5 Va E SS LAPT Drona WE SL O73 0 Tap n de Respiradero S a Mo F yO E
41. se peut inspecter tout produit sous garantie qui lui est retourn afin de confirmer que la garantie s applique avant d approuver la r paration ou le remplacement Cette garantie stipule l unique obligation de l Entreprise et le recours exclusif de l acheteur pour un produit d fectueux Retourner le produit d fectueux au d taillant pour les requ tes en garantie P RIODE DE GARANTIE PRODUITS 24 mois partir de la date d achat par l utilisateur Aucune garantie n est offerte pour les balais le rotor ou la came sur les mod les avec moteur balais et ou rotor flexible palettes En l absence d une preuve ad quate de la date d achat la p riode d application commencera partir de la date de fabrication CO TS DE MAIN D UVRE ETC EN AUCUN CAS l Entreprise ne pourra tre tenue responsable du co t de la main d uvre ou d autres frais encourus par un client lors de la d pose et ou de la r paration d un produit d une partie ou d un composant AM LIORATIONS DU PRODUIT L Entreprise se r serve le droit de modifier ou d am liorer ses produits ou une quelconque de leur partie sans obligation de fournir une telle modification ou am lioration aux appareils d j vendus et ou exp di s avant que de telles modifications ou am liorations n aient t apport es CONDITIONS ET MODALIT S G N RALES Cette garantie ne couvre pas les dommages caus s par une catastrophe naturelle l usure normale la fo
42. ta de agua lo cual puede durar de 5 a 10 segundos 7 Haga funcionar la bomba por 2 minutos y luego ap guela Saque los tapones del respiradero y de cargado 8 Usted ha completado el primer ciclo de cargado que consiste en los pasos del 2 al 7 Este proceso se tendr que repetir de 2 a 6 veces dependiendo del largo de su l nea de succi n Aproxima damente un ciclo de cargado por cada 5 pies de l nea de succi n Usted sabr cu ndo parar porque la bomba comenzar a bombear agua continuamente 9 Una vez que la bomba comience a bombear agua continuamente ajuste firmemente los tapones del respiradero y de cargado con una herramienta 10 Si la bomba no saca agua en 8 intentos ap guela y revise que no haya fugas de succi n Usando una v lvula de pie 1 Abra la v lvula de descarga en la l nea de servicio y un grifo cercano para controlar el flujo de agua 2 Vierta agua limpia por el agujero del tap n de cargado en la parte superior del cuerpo de la misma hasta que el agua comience a rebalsarse por el orificio del respiradero Usted necesitar aproxi madamente un litro de agua por cada 3 pies de l nea de succi n 3 Siga los pasos del 3 al 6 Si dentro de 2 minutos no se bombea agua continuamente apague la bomba Saque los tapones del respiradero y de cargado Repita los pasos del 2 al 6 Si esto no da resultados apague la bomba y revise que no haya fugas en la l nea de succi n 4 Una vez que la bomba comience a b
43. te antes de ensamblar 2 Lubrique ligeramente con agua jabonosa la tapa de caucho en el sello de cer mica 9 y emp jelo en la plancha selladora usando solamente sus dedos pulgares Aseg rese que la superficie lisa del asiento de cer mica quede hacia afuera NOTA Si la bomba va a estar fuera de servicio por m s de una semana entonces instale los componentes selladores en seco sin lubricaci n 3 Coloque la plancha selladora en el motor 4 Lubrique el sello rotativo 7 con agua jabonosa y desl celo en el eje con el anillo de carb n mirando hacia el asiento de cer mica 5 Coloque el propulsor 6 y el difusor 4 6 Coloque el casco de la bomba 2 asegur ndose que la junta no est da ada y que est en su lugar 7 Conecte las tuber as al casco y al interruptor de presi n 8 Conecte la electricidad 9 Cargue la bomba enci ndala y revise que no haya fugas GUIA PARA DETECTAR PROBLEMAS a b d e El motor no prende 1 No llega electricidad al interruptor de presi n debido a fusibles quemados interruptores abiertos o conexiones sueltas 2 El interruptor de presi n de la bomba no esta cerrado La bomba no bombea agua 1 La bomba no est cargada por completo 2 La altura de aspiraci n es demasiada 3 La v lvula de pie no est sumergida est enterrada en el lodo o est bloqueada La bomba pierde el agua que se le carga 1 Hay una fuga de aire en la l nea de aspirac
44. udre ou des conditions hors du contr le de l Entreprise et elle ne couvre pas non plus les services d entretien normaux et aux pi ces us es associ s a un tel service ni les produits qui selon le jugement exclusif de l Entreprise ont t expos s la n gligence l abus un accident une application inappropri e une alt ration une modification ni aux dommages caus s par une installation une utilisation un entretien ou un entreposage inad quat ni une utilisation au del des maximums La garantie est NULLE si l une des conditions suivantes s applique 1 Le produit est utilis pour des applications autres que celles pour lesquelles il a t con u et fabriqu Le produit n est pas install dans le respect des codes et r glements applicables et selon les bonnes pratiques accept es dans l industrie Le produit a t branch une tension autre que celle indiqu e sur la plaque signal tique La pompe a t utilis e avec des liquides autres que de l eau douce approximativement la temp rature ambiante La pompe a fonctionn sec alimentation en liquide coup e Le carter moteur scell a t ouvert ou le produit a t d mont par le client Le cordon a t coup une longueur inf rieure 0 9 m 3 pieds AVIS DE NON RESPONSABILIT Toute d claration verbale portant sur le produit faite par le vendeur l Entreprise les repr sentants ou toute autre partie ne constitue pas une garantie et
45. ulement 2 Obstruction partielle du clapet de pied de la conduite d aspiration de la roue ou de la buse Hauteur d aspiration trop lev e Mauvaise rotation de la roue ou r gime trop faible Le venturi ou le diffuseur est bouch Le moteur est c bl pour une tension non appropri e Le moteur ne parvient pas se lib rer de la phase d enroulements de d marrage R glage non appropri de l interrupteur de moteur D marrage et arr t trop fr quents de la pompe 1 Commande du volume d air d fectueuse 2 Fuite d air dans le r servoir au dessus du niveau de l eau 3 Mauvais r glage du manostat 4 Le r servoir est satur d eau ou trop petit pour l application choisie NO OB rt o o GARANTIE LIMITEE Lors des requ tes en garantie Franklin Electric Company Inc et ses filiales ci apr s appel e l Entreprise garantit les produits sp cifi s dans cette garantie contre tout d faut de mat riaux et de main d ceuvre Pendant les p riodes couvertes par la garantie et selon les conditions indiqu es dans la pr sente l Entreprise r parera ou remplacera toute partie de ce produit pr sentant une d faillance li e aux mat riaux ou a la main d uvre et ce uniquement aupr s du premier utilisateur ou acheteur En tout temps l Entreprise conserve le droit et l option de d terminer si un quipement des pi ces ou des composants d fectueux doivent tre r par s ou remplac s L Entrepri
46. uper son fonc tionnement et v rifier la tuyauterie d aspiration afin de s assurer qu il ny a aucune fuite Utilisation d un clapet de pied 1 Ouvrir le clapet de refoulement se trouvant sur la conduite de raccordement et pres du robinet pour surveiller le d bit d eau 2 Verser de l eau propre dans l orifice situ sur le dessus du bo tier et o sera install ult rieurement le bouchon d amorgage orifice d amorcage jusqu ce que la conduite d aspiration soit remplie et que l eau commence sortir par l orifice destin recevoir le bouchon vents Vous aurez besoin d environ un litre d eau pour chaque longueur de 3 pieds de conduite d aspiration 3 Suivre les tapes 3 6 ci dessus Si la pompe ne pompe pas d eau continuellement apr s 2 minutes il faut l arr ter retirer le bouchon vents le bouchon d amorcage et r p ter les tapes 2 a 6 ci dessus En cas d chec arr ter la pompe et v rifier la tuyauterie d aspiration afin de s assurer qu il n y a aucune fuite 4 Une fois que la pompe commence pomper de l eau de fa on con tinue bien serrer le bouchon vents et le bouchon d amorcage au moyen d une cl DRAINAGE Une conduite ventuellement gel e exigera le drainage de la pompe et du r servoir cet effet teignez l arriv e de courant la pompe depuis le panneau de commandes lectriques principal Ouvrez un robinet dans le syst me pour en lib rer la pression Enlevez
47. ustomer in removing and or affixing any product part or component thereof PRODUCT IMPROVEMENTS The Company reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such change or improvement GENERAL TERMS AND CONDITIONS This warranty shall not apply to damage due to acts of God normal wear and tear normal maintenance services and the parts used in connection with such service lightning or conditions beyond the control of the Company nor shall it apply to products which in the sole judgment of the Company have been subject to negligence abuse accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to excess of recommended maximums as set forth in the instructions Warranty will be VOID if any of the following conditions are found Product is used for purposes other than those for which it was designed and manufactured Product not installed in accordance with applicable codes ordinances and good trade practices Product connected to voltage other than indicated on nameplate Pump used to circulate anything other than fresh water at approximately room temperature Pump allowed to operate dry fluid supply cut off Sealed motor housing opened or product dismantled by customer 7 Cord cut off to a length less than three feet DISCLAIMER Any oral